FWMurphy AS705S Autostart Engine/Generator Controller User Manual
PDF
Dokument
Oglas
Oglas
ms5258 th revision B, 18 June 2001 catalog section 75 TM Autostart AS705S Automatic Engine/Generator Controller • Automatic or manual engine and generator control • LED indication of status/faults • Custom LEDs and labelling • Programmable timers, inputs, outputs and control options D escription The AS705S provides fully automatic control, fault monitoring and shutdown of a standby generator, pump or engine driven application. Features include:• Automatic or manual control, keyswitch or rotary switch selectable • Status and fault indication by 17 LEDs. 12 have preset labelling, 5 may be custom programmed and labelled. • Wide range power supply, 5 to 40 VDC. • Automatic, timed control of generator contactor. • Electrical connection by two-part, screw terminal blocks. • Tamper proof settings. Timers, I/O and control options are set using a PC serial link and free of charge software. • Compact, front of panel mounting Application The Autostart series may be used in any unmanned application where automatic engine starting and stopping is required. The AS705’s control, measurement and display features allow it to be used in place of multiple control units, trip relays and indicating gauges, and at a fraction of the cost. For further details, please contact your Murphy representative, or visit www.fwmurphy.co.uk/as7xx Warranty A two year limited warranty on materials and workmanship is given with this Murphy product. Details are available on request and are packed with each unit. Product Specification Power supply: Operating voltage: steady state range 5 – 40 V DC continuous, crank brown-out to 0 V for <= 100 mSec Current consumption typically 150 mA Inputs: DC inputs (inputs 1 - 5, rem. start): positive input voltage range 80% to 100% of positive DC negative input voltage range -1V to +2V w.r.t. negative DC Generator AC input: operating voltage range 90 – 300 V AC rms single phase frequency measurement range 0 – 99 Hz. Magnetic pickup: operating voltage range 7 – 80 V AC rms frequency measurement range 0 – 10 kHz Outputs: (all ratings for resistive load) Start and fuel relays positive DC (switched relay) 16A max. @ 24 V DC Programmable outputs 1 – 3 negative DC (semiconductor) 250mA max. @ 33 V DC Programmable output 4 negative DC (switched relay) 5A max. @ 24 V DC Programmable output 5 postive DC (switched relay) (default setting: common alarm) 5A max. @ 24 V DC Programmable output 6 volt free SPNO relay (default setting: gen. contactor) 5A max. @ 240 V AC Auto & Manual outputs positive DC (switch), 250 mA max. Off/reset output negative DC, 250 mA max. General: Overall dimensions (W x H x D) 96 x 96 x 162 mm Panel cut-out size DIN standard 92 x 92 mm Weight approx. 650 g Operating ambient temperature –10 to +55 oC Front Facia Rear Facia and Electrical Connection 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 LED indicators:- Preset x 10 - Programmable x 5 - Auto mode x 1 Manual mode x 1 Custom label sheet 3 position operating mode switch (keyswitch shown):Off/reset Auto Manual How to order 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 –ve DC supply 5 – 40 VDC Charge fail input + ve DC power supply + ve DC (relays)/Emerg. stop Magnetic pickup input – ve DC Output 1 250 mA max Output 2 A800 enable output Output 3: – ve, < 250mA Output 4: – ve DC, 5 A max. Remote start/mains fail input - No connection Off output: – ve, < 250mA Manual output + ve DC Auto output 250mA max. Communications Port 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Input 1: low oil pressure Input 2: high engine temp. Input 3: programmable Input 4: programmable Input 5: programmable Index Pin Fuel output +ve DC Starter output 16 A max. Output 5 (alarm): + ve, < 5A NO Output 6 (gen. contctr) CO volt free, 5 A max. – ve Man. Start Man. Stop Live Generator AC Neutral 300 VAC max. Program options: Stock code Model / Description 76.70.0065 AS705SKD, keyswitch, 230VAC 76.70.0037 AS705SRD, rotary switch, 230VAC 76.70.0011 AS705SKC, keyswitch, 110VAC 76.70.0219 AS705SRC, rotary switch, 110VAC Programming accessories:76.70.0018 AS7CA, 9 to 9 way local comms lead 76.70.0019 AS7CB, 9 to 25 way local comms lead 76.70.0020 AS7CC, local comms interface 76.70.0203 AS7CK, PC program and monitor software for AS7xx series. Also available for free of charge download from: www.fwmurphy.co.uk/download TM FWMurphy Murphy PO Box 470248 Tulsa, Oklahoma 74147, USA tel: (918) 627 3550 fax: (918) 664 6146 email: [email protected] web: www.fwmurphy.com CONTROL SYSTEMS AND SERVICES DIVISION PO Box 1819, Rosenberg, Texas 77471, USA tel: (281) 342 0297 fax: (281) 341 6006 email: [email protected] MURPHY DE MEXICO S.A. DE C.V. Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P. México 78384 tel: + 52 48 206264 fax: + 52 48 206336 email: [email protected] web: www.murphymex.com.mx The AS705 is programmed using PC software model AS7CK, available for free of charge website download. During setup, AS705 and PC are connected by local serial link (using the accessories listed left). Over 50 programmable functions allow custom set-up for your application:Timers: start delay, preheat, crank, crank rest, no. of start attempts, alarm override, engine warmup, speed signal, (mains AC) restoration, cooldown, (fuel) energised to stop. Inputs: input 1 – 5 configuration (open/close/+ve/-ve); input 3 – 5 actions (shutdown, warning, indication, load release, lamp test, manual restore, test, alarm mute, load reset) Outputs: 6 outputs, each set for one of 40 signalling and control options, e.g. preheat, energised to stop fuel, engine running, muteable alarm, individual faults, etc. Generator: trip Hz/RPM levels and response for crank release, underspeed, overspeed, speed overshoot on start. DC: high and low battery voltage warning, charge fail settings (charge alternator WL or battery charger), WL crank release. LEDs: allows programming of the LED indicators (including the 5 with custom message windows). See document mi5265 for a full list of program options. Software AS7CK also features real time monitoring and display of engine parameters – see document mi5266 for full details. FRANK W. MURPHY LTD. Church Rd, Laverstock, Salisbury, SP1 1QZ, UK tel: +44 1722 410055 fax: +44 1722 410088 email: [email protected] web: www.fwmurphy.co.uk For service in French:Pour service en français:tél: +44 1722 410697 fax: +44 1722 410088 email: [email protected] web: www.fwmurphy.co.uk/francais.htm MURPHY SWITCH OF CALIFORNIA 41343 12th Street West, Palmdale, CA 93551-1442, USA tel: (661) 272 4700 fax: (661) 947 7570 email: [email protected] web: www.murphyswitch.com MACQUARRIE CORPORATION 1620 Hume Highway, Campbellfield, Victoria 3061, Australia tel: +61 3 9358 5555 fax: +61 3 9358 5558 email: [email protected] In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. ">
/
Prenesi
Samo prijazen opomnik. Dokument si lahko ogledate tukaj. Najpomembneje pa je, da ga je naša umetna inteligenca že prebrala. Lahko razloži zapletene stvari na preprost način, odgovori na vaša vprašanja v katerem koli jeziku in vam pomaga hitro krmariti tudi po najdaljših ali najbolj zapletenih dokumentih.
Oglas