Renishaw NCPCB tool setting device Data Sheets
Annonce
Annonce
Data sheet
H-2000-2038-06-A
NCPCB tool setting device
www.renishaw.com/ncpcb
The NCPCB tool setting device is used for rapid tool setting, tool wear monitoring, run out checking, and tool breakage detection on PCB drilling machines.
4.8
30.4
4.2
80
75.5
It is specifically designed to work with SIEB & MEYER
44.20.020, 44.20.020A, and 44.20.0120 laser cards.
Mounting screw,
M3 x 0.5, 30 long, low head cap (no spacer)
Support the cable during installation to limit strain
Spacer
Mounting screw,
M3 x 0.5,
30 long, low head cap
18
12.5
17.5
20.2
25
Ø
Beam C/L
8.15
8.10
Detail A
(Datum feature)
18.8
25.9
9
Datum feature
(see detail A)
Status indicator
Ground tag
6.5 x 2.8 x 0.5
Remove protection cap before installing the pipe
Must be connected to the machine ground.
Mounting screw and spacer.
Note: Ensure spacer is fitted.
Head of fixture screw must be level with top face.
Prestolok micro air fitting, Ø 4 mm pipe
This end is plugged as standard. To enable air entry at this end, remove the plug and refit at the cable entry end.
Air fitting must only be used with calibrated 4 mm polyamide tubing (in accordance with DIN 73378,
BS 5049, Part 2, NF E49-100, CETOP RP4581) and polyurethane (in accordance with NF E49-101)
Cable exit
15.5
Beam
33
27 26
19
5.8
24.8
11
Connection
Wire
Select
Reference voltage
Signal
(output)
Ground
Power
Shield
Colour Requirements
Grey 5 V off, 0 V on
Yellow 0 V to 5 V (2.5 V nominal) input impedance 10 kOhms
Green Beam broken: 0 V sink, 12 mA
Not broken: 5 V source, 12 mA
HCMOS. Rise time1 µs
White 0 V
Brown 5 V ± 0.1 V, 60 mA
Black Must be connected to machine’s chassis
NOTE: When power is applied to the unit, light from the beam will be visible. Applying 0 V to the select (grey) wire will switch on the unit, the status LED will light, and the beam intensity will increase.
Operation
Select
(grey) wire
0 V
0 V
Beam condition
Broken
5 V Off
Not connected Off
Signal (output)
(green wire)
0 V
Not broken 5 V
0 V
0 V
LED
Off
On
Off
Off
Reference voltage
(yellow) wire
5 V
2.5 V
0 V
Effect
Increases measured Ø
Factory setting
Reduces measured Ø
Renishaw plc
New Mills, Wotton-under-Edge,
Gloucestershire, GL12 8JR
United Kingdom
T +44 (0)1453 524524
F +44 (0)1453 524901
www.renishaw.com
Specification
Operating temperature 10 °C to 40 °C
Storage temperature -10 °C to 70 °C
IP rating IP50
Repeatability
Life
0.5 µm 2s
> 1 million on/off cycles
Min. tool Ø 0.10 mm tool setting
0.08 mm breakage
Pneumatic supply
Cable
Weight
Mounting
Via 4 mm push-fit connector,
0.5 bar min., 3 bar max.
ISO 8573-1: Air quality of class 1.7.2
5-core plus screen cable.
Each core 18/0.1 insulated.
Ø4.85. Length either 0.8 m or 2 m
130 g
Mounting screws, M3 x 0.5,
30 long, low head cap (2 off) and spacer (1 off), as detailed on the previous page
Care of equipment
Keep system components clean and treat the NCPCB as a precision tool.
Changes to Renishaw products
Renishaw reserves the right to change equipment specifications without notice.
Warranty
Equipment requiring attention under warranty must be returned to your equipment supplier. No claims will be considered where
Renishaw equipment has been misused, or where repairs or adjustments have been attempted by unauthorised persons.
Prior consent must be obtained in instances where Renishaw equipment is to be substituted or omitted. Failure to comply with this requirement will invalidate the warranty.
Patents
Features of the NCPCB, and related products, are subject to patent applications:
IMPORTANT: Do not remove the cover-securing screws as this will affect beam alignment. Removal of the screws will also invalidate the warranty.
Air connection
A continuous supply of clean dry air ensures maintenance-free operation of the unit. Under clean and dust-free conditions the air supply may be omitted.
Safety
It is the responsibility of the machine supplier to ensure that the user is made aware of any hazards involved in the operation of their machine, including those mentioned in Renishaw product documentation, and to ensure that adequate guards and safety interlocks are provided. Under certain circumstances the device signal output may falsely indicate the status of the beam. Do not rely on the device signals to stop machine movement.
Parts list
Please quote the part number when ordering equipment.
Purge the air lines before connecting. The air supply is connected via a 4 mm push-fit connector situated adjacent to the cable exit. The supply must be continuous, clean, and dry (to ISO 8573-1: air quality of class 1.7.2) at a minimum pressure of 0.5 bar (7 psi). The pressure can be adjusted up to
3 bar (43.5 psi) maximum for tool cleaning.
Failure to maintain air quality will result in performance degradation or product failure. If contamination is suspected, return the product for repair.
Type Part No.
Description
NCPCB A-4111-0001 NCPCB unit, two mounting screws, 0.8 m cable
NCPCB A-4196-1000 NCPCB unit, two mounting screws, 2 m cable
Trademarks
RENISHAW® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries.
apply innovation is a trademark of Renishaw plc.
C
EC DECLARATION OF CONFORMITY
All other brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their respective owners.
Renishaw plc declares that the NCPCB complies with the applicable standards and regulations. A copy of the EC
Declaration of Conformity is available on request.
For worldwide contact details, please visit our main web site at www.renishaw.com/contact
Copyright
© 2001–2010 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw plc.
The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT
AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT.
RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
© 2001-2010 Renishaw plc. All rights reserved.
Issued 06.10
*H-2000-2038-06*
Part no. H-2000-2038-06-A
Download
Annonce