Sentry : Solutions for the Data Center Equipment Cabinet
Sentry Metered CDU
C-12H2
Key Features
> Mid Density: Single-power input feed; 12 outlets per rack-mount 1U enclosure
>Power Distribution: 208-240V or 230V power options; 16, 20,
30, or 32-Amp power input feed options.
> Input Current Monitor:
Precisely measure the aggregate current draw (in amps) on each power circuit.
On-site verification of the input current with the LED digital display.
Mid-Density Metered Power Distribution
Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU. The Sentry CDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (CDU) has a local LED input current monitoring, allowing network engineers to utilize the CDU’s True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new servers and devices are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
Additional Benefits:
Branch Circuit Protection
The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection.
Attention! The Sentry CDU products meet the above criteria by providing overcurrent protection with UL-listed Bussman SC fuses for each branch circuit.
Input Current Monitoring
Exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital display on the CDU enclosure report the input current of the branch circuit.
Sentry : CDU Technical Specifications
Model
C-12H2-C20M
C-12H2-L30M
C-12HE-C20M
C-12HE-P32M
Available Input
Voltages
208-240V
50/60Hz
208-240V
50/60Hz
230V
50/60Hz
230V
50/60Hz
Additional Specifications
Agency Approvals
> US & Canada (cTUVs mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
> European Union (TUVGS mark) to EN
60950-1:2001
> FCC Class A, Part 15
> CE
> EMC to EN 55022 Class A, EN 55024 CISPR 22
Class A
Branch Circuit Protection
> Compliant to UL 60950-1
Amperage
20A
30A
16A
32A
Available Input
Cord
IEC 60320/C20
Power Inlet
NEMA L6-30P
Cordset 10ft (3m)
IEC 60320/C20
Power Inlet
IEC 60309
Cordset 10ft (3m)
Outlets
(12) IEC 60320/C13
(12) IEC 60320/C13
(12) IEC 60320/C13
(12) IEC 60320/C13
Dimensions
(L x W x D)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
> PTCORD-2 IEC 60320/C19 - Schuko 10ft (3m)
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)
16/20A Blue (UK Commando) 10ft (3m)
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade)10ft (3m)
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade)10ft (3m)
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10ft (3m)
HEADQUARTERS -
NORTH AMERICA
Server Technology, Inc.
1040 Sandhill Drive
Reno, NV 89521
United States
1.775.284.2000 Tel
1.775.284.2065 Fax [email protected]
www.servertech.com
www.servertechblog.com
EMEA
Server Technology Intl
Sienna Court
The Broadway
Maidenhead
Berkshire
SL6 1NJ
United Kingdom
+44 (0) 1628 509053 Tel
+44 (0) 1628 509100 Fax [email protected]
APAC
Server Technology Intl
37th Floor, Singapore Land Tower
50 Raffles Place
Singapore 048623
+65 (0) 6829 7008 Tel
+65 (0) 6234 4574 Fax [email protected]
© Server Technology, Inc.12/2010 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc. Printed in US.
Sentry : Solutions for the Data Center Equipment Cabinet
Sentry Metered CDU
C-12H2
Key Features
> Mid Density: Single-power input feed; 12 outlets per rack-mount 1U enclosure
>Power Distribution: 208-240V or 230V power options; 16, 20,
30, or 32-Amp power input feed options.
> Input Current Monitor:
Precisely measure the aggregate current draw (in amps) on each power circuit.
On-site verification of the input current with the LED digital display.
Mid-Density Metered Power Distribution
Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU. The Sentry CDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (CDU) has a local LED input current monitoring, allowing network engineers to utilize the CDU’s True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new servers and devices are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
Additional Benefits:
Branch Circuit Protection
The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection.
Attention! The Sentry CDU products meet the above criteria by providing overcurrent protection with UL-listed Bussman SC fuses for each branch circuit.
Input Current Monitoring
Exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital display on the CDU enclosure report the input current of the branch circuit.
Sentry : CDU Technical Specifications
Model
C-12H2-C20M
C-12H2-L30M
C-12HE-C20M
C-12HE-P32M
Available Input
Voltages
208-240V
50/60Hz
208-240V
50/60Hz
230V
50/60Hz
230V
50/60Hz
Additional Specifications
Agency Approvals
> US & Canada (cTUVs mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
> European Union (TUVGS mark) to EN
60950-1:2001
> FCC Class A, Part 15
> CE
> EMC to EN 55022 Class A, EN 55024 CISPR 22
Class A
Branch Circuit Protection
> Compliant to UL 60950-1
Amperage
20A
30A
16A
32A
Available Input
Cord
IEC 60320/C20
Power Inlet
NEMA L6-30P
Cordset 10ft (3m)
IEC 60320/C20
Power Inlet
IEC 60309
Cordset 10ft (3m)
Outlets
(12) IEC 60320/C13
(12) IEC 60320/C13
(12) IEC 60320/C13
(12) IEC 60320/C13
Dimensions
(L x W x D)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
17.0 x 1.75 x 5.0 in
(431 x 44 x 127 mm)
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
> PTCORD-2 IEC 60320/C19 - Schuko 10ft (3m)
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)
16/20A Blue (UK Commando) 10ft (3m)
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade)10ft (3m)
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade)10ft (3m)
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10ft (3m)
HEADQUARTERS -
NORTH AMERICA
Server Technology, Inc.
1040 Sandhill Drive
Reno, NV 89521
United States
1.775.284.2000 Tel
1.775.284.2065 Fax [email protected]
www.servertech.com
www.servertechblog.com
EMEA
Server Technology Intl
Sienna Court
The Broadway
Maidenhead
Berkshire
SL6 1NJ
United Kingdom
+44 (0) 1628 509053 Tel
+44 (0) 1628 509100 Fax [email protected]
APAC
Server Technology Intl
37th Floor, Singapore Land Tower
50 Raffles Place
Singapore 048623
+65 (0) 6829 7008 Tel
+65 (0) 6234 4574 Fax [email protected]
© Server Technology, Inc.12/2010 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc. Printed in US.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement