HEAT RECOVERY VENTILATOR EE VIGÖR™ HRV Part no. 44200 Controls


Add to my manuals
2 Pages

advertisement

HEAT RECOVERY VENTILATOR EE VIGÖR™ HRV Part no. 44200 Controls | Manualzz
®
HEAT RECOVERY VENTILATOR
VÄNEE
VIGÖR™ HRV
Part no. 44200
35 to 70 CFM (0.4 in. w.g.)
Controls
This unit is very simple to operate: once it is installed, use
its push button, located on the unit top left side, to
control it.
Also, up to 5 of the following auxiliary wall controls can
be added:
- 20-min. lighted push button
no. 1806110
- 60-min. crank timer
no. 00910
- Humidity Control
no. 200694
Options
Complete line of registers and diffusers
Exclusive wall mounting bracket
no. 19255
VB0142
THE VIGÖR™ HRV:
PUNY PRICE TAG, LOTS TO LOVE!
The Vigör™ HRV is the ideal choice for condominiums,
apartments and other limited space applications that
require up to 70 cfm of continuous ventilation. With its
compact size and 4-inch vertical ports, it can be installed
in small spaces such as a closet or mechanical room above
a hot water tank.
At just 30 lb (13.6 kg), it can be installed without
opening the unit
Features integrated hooks to simplify installation
Removable terminal block to ease auxiliary wall control
connections
Less than 4 sones at 64 cfm
REPAIRS AND MAINTENANCE
Defrosting System
The Vigör™ HRV defrosts on a fixed cycle of 25 minutes air
exchange and 5 minutes defrost, independent of the
outside temperature.
Heat Recovery Core
Dimensions: 10" x 10" x 5.5" (25.4 cm x 25.4 cm x 14 cm)
Exchange surface: 42.3 ft² (3.9 m²)
Weight: 4 lb (1.8 kg)
Material: Polypropylene
Type: Crossflow
Warranty: Limited Lifetime
All parts of the Vigör™ HRV that could need maintenance
can be removed in less than five minutes, allowing direct
access for easy repairs. The PSC motor is permanently
lubricated.
WARRANTY
The Vigör™ HRV is protected by a 2-year warranty on parts
only. The heat recovery core is covered by a limited
lifetime warranty, with the original proof of purchase.
Requirements and Standards
Available at:
Complies with the UL 1812 requirements regulating the
installation of Heat Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard applicable
to ventilators
Complies with CSA C444 requirements regulating the
installation of Heat Recovery Ventilators
Technical data was obtained from published results of
tests relating to CSA C439 Standards
HVI certified
Dimensions: Vigör™ HRV
Ventilation Performance
EXT. STATIC
PRESSURE
PA IN. W.G.
25 0.1
50 0.2
75 0.3
100 0.4
125 0.5
150 0.6
175 0.7
200 0.8
225 0.9
1: FRESH AIR TO BUILDING PORT
2: EXHAUST AIR FROM BUILDING PORT
3: FRESH AIR FROM OUTSIDE PORT
4: EXHAUST AIR TO OUTSIDE PORT
1
2
15 7/16”
3
NET SUPPLY
AIR FLOW
M³/H
L/S CFM
39 82
139
37 78
133
35 73
124
33 71
121
31 66
112
30 63
107
28 59
100
25 54
92
23 49
83
L/ S
39
38
35
34
32
30
28
26
24
GROSS
SUPPLY
CFM
M³/H
83
141
80
136
74
126
72
122
67
114
64
109
60
102
55
93
50
85
AIR FLOW
EXHAUST
L/ S
CFM
M³/H
43
40
39
37
35
33
31
28
26
90
86
82
78
73
71
65
60
55
153
146
139
133
124
121
110
102
93
4
3 FT.
POWER CORD
Ø
4” TYP.
Energy Performance
2 3 /8 ”
POWER
SUPPLY
SENSIBLE
APPARENT LATENT RECOVERY/
NET AIR FLOW
CONSUMED RECOVERY
SENSIBLE
MOISTURE
TEMPERATURE
ºC
ºF
L /S CFM M³/H WATTS
EFFICIENCY EFFECTIVENESS TRANSFER
HEATING
0
32 17 36 61
40
55
70
0.01
54
48
59
0.02
0
32 31 65 110
-25 -13 18 38 65
41
53
72
0.01
COOLING
TOTAL RECOVERY EFFICIENCY
35 95 - -
18 5/8”
16 5/16”
15 1/16”
VK0074A
15 5/8”
NOTE: All specifications are subject to change without notice.
Specifications and Ratings
Model: Vigör™ HRV
Part Number: 44200
Total Assembled Weight (including
polypropylene core): 30 lb (13.6 kg)
Round 4" ducts
Drain: 1/2" (1.2 cm) fittings with
10 ft (3 m) PVC drain
Core filters: 2 washable Merv 6
9.2" x 14.25" x 3.8"
(23.4 cm x 36.2 cm x 9.6 cm)
PROJECT:
LOCATION:
MODEL
Housing: Pre-painted steel
Insulation: Expanded polystyrene
Mounting: Suspension by chains and
springs or optional wall bracket
Supply &
1 motor
Exhaust
Blower
Motor:
- Protection type: Thermally protected
- Insulation class: B
Speed Control on unit: Low speed
and Standby
Other modes available with auxiliary
wall controls
Heat Recovery Core:
- Heat Exchange Surface Area:
42.3 ft² (3.9 m²)
- Type: Crossflow
- Material: Polypropylene
Unit Electrical Characteristics:
Volts Frequency Ampere
Watts
120
60 Hz
0.5
60
REMARKS
NO.:
QTY.:
SUBMITTED
BY:
DATE:
®
Residential Product Group, 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715
www.vanee-ventilation.com
VigorHRVd110511

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project