Data Collection Terminal
8:20 AM 04-10-00
QZ.
1
GHI
4
JKL
5
CLEAR
BACK
SPACE
ALPHA
OUT
ENTER
IN
HARDWARE MANUAL
FCC Warning:
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, it may cause interference with the radio and television reception in a residential area, in which case the user will be required to correct the interference at his or her own expense.
If this equipment causes interference, try to correct the problem by:
Reorienting the receiving antenna.
Relocating the terminal with respect to the receiver with which it interferes.
Plugging the terminal into a different AC outlet, and putting the terminal and receiver on different branch circuits.
FCC Compliance: (on hardware equipped with modem)
This equipment complies with Part 68 of FCC Rules. Upon request, furnish the following information to the telephone company (telco).
Manufacturer: Acroprint Time Recorder Co., Inc.
Model: Badger II Terminal
FCC registration number: 4G3USA-21602-DT-E
Ringer equivalence: 0.7B
USOC modular telephone jack: R-J11
Lithium Battery Caution:
This circuit board on this terminal is populated with a lithium battery to protect data or programs stored in the Random Access Memory (RAM). Do not, under any circumstances, attempt to replace the lithium battery in the terminal.
Failure to comply may invalidate your warranty. Battery replacement should be done by qualified personnel wearing the proper eye protection.
CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Discard used batteries according to the manufacturers instruction.
Declaration Of Conformity According To EMC Directive 89/336/EEC
We declare under our sole responsibility that the magnetic stripe and/or bar code reading and/or data recording equipment Badger II 01-0119-000/003/
005/007 to which this declaration relates are in conformity with the following standards: EN55022:1987, EN50082-1, IEC 801-2, IEC 801-3, IEC 801-4,
IEC 801-5. I, the undersigned, hereby declare that the equipment specified above conforms to the above directive and standards.
Raleigh, North Carolina USA
October 7, 2002
All Rights Reserved. © COPYRIGHT 1996
Acroprint Time Recorder Company
W. Glenn Robbins
2
Table of Contents
1. Introduction ................................................................. 4
Basic hardware and variations ................................................ 4
General specifications............................................................. 5
2. Setup ............................................................................ 6
Site requirements .................................................................... 6
Unpacking and inspection ...................................................... 6
Mounting................................................................................ 7
Power up ................................................................................. 7
3. Operator interface ....................................................... 8
ADCT Keypad ........................................................................ 8
DataLog Keypad ..................................................................... 8
Card reader ............................................................................. 9
4. Ports and connections ............................................. 10
Acroprint Data Collection Terminal setup instructions ........ 10
Ethernet port ......................................................................... 13
RS-232 Serial port ................................................................ 14
RS-232 Serial printer cables ................................................... 15
Local Area Network: RS-485 serial port .............................. 16
RS-485 Serial cables............................................................. 17
Modem port .......................................................................... 18
Modem cables ....................................................................... 19
Wand port ............................................................................. 20
Wand and Y-Cable ................................................................ 21
Parallel port........................................................................... 22
Parallel cable......................................................................... 23
5. Companion products ................................................ 24
Printer ................................................................................... 24
Readers ................................................................................. 24
Power Supplies ..................................................................... 25
External Relay Box, External Buzzer ................................... 25
Cables ................................................................................... 26
Cables, Converter, Badge Racks........................................... 27
Table of Contents 3
1. Introduction
Basic hardware and variations
The electronic hardware is a new, versatile platform designed for use with various applications. This manual describes, in detail, the electronic hardware aspects of the terminal you have purchased.
The details concerning terminal firmware and host software are addressed in the manual which comes with the software.
All terminals are equipped with:
1) a magnetic stripe reading head
2) a 2 row x 20 character per row display
3) a 16-key full travel keypad
4) an RS-232 serial port
5) a wand port for optional bar code wand
6) two control lines for external relay control (door access, and bell ringer are typical applications)
7) a 25-pin parallel port
The terminal is offered in different hardware variations. Listed below are the variations by part number and description:
Part # Description
C - Programmable e-prom (DataLog)
01-0120-000
01-0120-002
01-0120-003
01-0120-004
01-0120-005
DataLog with LAN (RS-485)
DataLog with Modem (no LAN)
01-0120-006
01-0120-008
01-0120-010
01-0120-012
DataLog with LAN & Internal Visible Bar Code Reader
DataLog with Modem & Internal Visible Bar Code Reader
DataLog with LAN & Internal Infrared Bar Code Reader
DataLog with Modem & Internal Infrared Bar Code Reader
DataLog with Ethernet
DataLog with Ethernet & Internal Visible Bar Code Reader
DataLog with Ethernet & Infrared Bar Code Reader
Acrocomm e-prom (Acroprint Data Collection Terminal ADCT)
01-0147-000
01-0147-002
01-0147-003
01-0147-004
01-0147-005
01-0147-006
01-0147-008
01-0147-010
01-0147-012
Acroprint with LAN (RS-485)
Acroprint with Modem (no LAN)
Acroprint with LAN & Internal Visible Bar Code Reader
Acroprint with Modem & Internal Visible Bar Code Reader
Acroprint with LAN & Internal Infrared Bar Code Reader
Acroprint with Modem & Internal Infrared Bar Code Reader
Acroprint with Ethernet
Acroprint with Ethernet & Internal Visible Bar Code Reader
Acroprint with Ethernet & Infrared Bar Code Reader
Note: The part number of your unit can be found on the serial number label on the back of the terminal.
4 Introduction
General specifications
C. Z-180 Microprocessor.
E. Lithium battery backed RAM.
F. Real Time Clock Chip on-board.
H. Display: 2 lines with 20 characters on each line. ADCT is backlit.
L. Parallel port: 25-pin DB connection.
N. Internal Multi-Frequency Piezo Electric Buzzer.
Q. External Bar Code port: 6-pin DIN connection for external
Bar Code Wand or Bar Code Gun.
Introduction 5
2. Setup
Site requirements
The terminal can be installed in any normal office or controlled factory environment. However, do not use the terminal under the following conditions:
extremely high or low temperature
[operating temperature range: 0° to 50° C (32° to 122° F)]
[storage temperature range: -20° to 60° C (-4° to 140° F)]
extremely high or low humidity
[operating humidity range : 0 to 90% RH non-condensing]
areas of high dust concentration
areas with chemical fume concentration
areas with extreme vibration or when placed on an unstable or unlevel surface
Unpacking and inspection
Having opened the shipping carton, carefully remove the contents. Inspect the terminal and accessories for damage. Report damage or shortages to the company from which the unit was purchased. Complete the registration card with all important information.
8:20 AM 04-10-00
GHI
4
IN
CLEAR
ALPHA
OUT
ENTER
(1) Terminal
(1) Power Supply
Data Collection Terminal
QZ.
1
GHI
4
PRS
7
IN
JKL
5
TUV
8
-SP
0
DEF
3
CLEAR
BACK
SPAC
E
MNO
6
WXY
9
ALPHA
OUT
ENTER
HARDWARE MANUAL
(1) Manual (4) Mounting Screws
6 Setup
Mounting
Unscrew the access door. With the door off, the main unit can be slid upward and removed from the mounting bracket. The bracket can be used for wall mounting, or it can be reversed to tilt the unit on a desktop.
Power up
Plug in the power cord coming from the wall mount transformer into the terminal. Reattach the access door and secure the unit to the reversible bracket. Replace screw on the access door.
NOTE: Other connections are made in the same fashion. Notice the channels in the bracket available for cable routing. Also, the bracket has through-holes for further securing of cables using ties.
Setup 7
3. Operator interface
ADCT Keypad
The terminal has 16 keys for entering alphabetical and numeric data as illustrated below.
QZ.
1
GHI
4
PRS
7
IN
ABC
2
JKL
5
TUV
8
-SP
0
DEF
3
MNO
6
WXY
9
CLEAR
BACK
SPACE
ALPHA
OUT ENTER
DataLog Keypad
The terminal has 16 keys for entering data as illustrated below.
1 2 3
4 5 6
7 8 9
0
CLEAR
MENU
MENU
ENTER
8 Operator interface
Card reader
The terminal has an internal magnetic stripe card reader. The magnetic stripe on the card should be on the right side when the card is swiped as shown below.
Bar Code - left side
Magnetic stripe right side
Optionally, the terminal can also have an internal bar code reader.
The card is swiped through in the same fashion, but the Bar Code should be on the left side of the card when swiped.
1.00" Min.
NOTE: For through-the-slot reading, Bar Code should be located on card as shown.
Operator interface 9
4. Ports and connections
Acroprint Data Collection Terminal setup instructions
Configuring procedure for entering the DATE & TIME:
Swipe the Configuration Badge 000000000
(This badge is provided with each terminal)
Select option 1 for DATE <Press ENTER>
Select the Day, Month, Year DDMMYYYY <Press ENTER>
Select the Time HH:MM <Press ENTER>
(Time is entered in military time, 2:00 pm = 14:00)
Configuring procedure for selecting PORTS:
Swipe the Configuration Badge 000000000
(This badge is provided with each terminal.)
Select option 2 for Ports <press ENTER>
Select option 0 for RS232 <press ENTER>
Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600 and 4 for 19,200 baud. <press ENTER>
(For modem terminal only)
Select option 1 for Modem <press ENTER>
Select the Modem baud rate 0 for 1200 and 1 for 2400 baud
<press ENTER>
Select the Answer Window HHMMHHMM for starting and ending times <press ENTER> (time is in military format, Example:
Clock will not answer during business hours and only answer between the hours of 8:00 pm and 6:00 am, then select 20000600.)
10 Ports and connections
(For RS485 terminals only)
Select option 1 for RS485 <press ENTER>
Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600 and 4 for 19,200 baud. <press ENTER>
(For Ethernet terminals with ATR9800 only)
Select option 2 for Ethernet <press ENTER>
Select the baud rate option 3 for 9600 baud <press ENTER>
(Leave this as the default for Ethernet.)
Select the TCPIP address <press ENTER>
(Your network administrator will have this information.)
Select the GATEWAY address <press ENTER>
(Your network administrator will have this information.)
Select the PORT VALUE <press ENTER>
(Default number 10001. Select the same value in the ATR9800 software.)
Select the NETMASK VALUE <press ENTER>
(Your network administrator will obtain this information. The
Network SubNetMask TCPIP number contains 4 elements of numbers separated by .. To determine the NETMASK VALUE obtain your Network SubnetMask IP number from the Network administrator, i.e. XXX.255.255.000. Convert the last three elements
(your numbers will be different) to binary and count the total number of zeros in each binary element and enter this number. 255 =
11111111 in binary, 000 = 00000000. Each 255 contains NO zeros therefore the Netmask value bits number is set to 08 for the example
XXX.255.255.000.) The Ethernet terminal Netmask values can range from 01 to 24.
Select the TERMINAL TRANSACTION PRINTER TYPE
<press ENTER>
(default is parallel port)
Ports and connections 11
Select TRANSACTION TIME OUT <press ENTER>
(This controls how long the terminal will restrict between badge swipes. Example: You want to keep your employees off the terminal for at least 30 minutes for lunch, then set Transaction Time Out to 30.)
Select TERMINAL ID <press ENTER>
(default is 1, select the ID for terminal, each terminal MUST have a unique ID)
The terminal MUST be powered down and back up to accept the new TCPIP information.
Configuring procedure for selecting the READERS:
Swipe the Configuration Badge 000000000
(This badge is provided with each terminal.)
(Select any combination 1234 to activate the readers. 1 for Internal Barcode, 2 for External Barcode, 3 for Internal Magnetic
Stripe and 4 for Internal Proximity Reader) Note, if 4 is selected then the External Barcode Reader will be disabled.
Note, if you turned OFF all readers you will be unable to read the configuration badge. The following procedure will allow you to re-enable the readers. Press the IN, then the OUT and then the
ENTER key within 1 second. The terminal will go into a testing mode. Press the Clear key, press the IN key, then the OUT key and then the ENTER key within 1 second or before the time is displayed.
12 Ports and connections
Ethernet port
The Ethernet port is located on the lower left corner of the terminal. It is a 10 position 8-pin female port which will accept a male 10BASE-T (RJ-45) modular connector. The terminal has the capability to communicate across an intranet, a WAN or the
Internet.
Note: Ethernet communicates via TCPIP 10BASE-T only.
W
AND
Ports and connections 13
RS-232 Serial port
The RS-232 serial port is located on the lower left corner of the terminal. It is a 6 position 4-pin female port which will accept a male RJ-11 modular connector.
The Acroprint Data Collection
Terminal can use RS-232 serial communication to connect directly to a host computer. A connection for an IBM PC or compatible is shown below.
W
AND
Cabling to Host Computer with DB-25 Port
(Use DB-25 RS-232 Host Cable Assembly. See page 26.)
DB-25 to RJ-11 Adaptor
(Adaptor A)
"Standard" Modular Cable
Schematic
NOTE: Schematic connections are shown from END VIEW. (As viewed from the outside of the connectors.)
Schematic
Cabling to Host Computer with DB-9 Port
(Use DB-9 RS-232 Host Cable Assembly. See page 27.)
DB-9 to RJ-11 Adaptor
(Adaptor A)
"Standard" Modular Cable
Schematic
NOTE: Schematic connections are shown from END VIEW. (As viewed from the outside of the connectors.)
14 Ports and connections
Schematic
RS-232 Serial printer cables
The terminal serial port is used for connection to a serial printer.
Printers, such as the serial printer shown on page 24, use a circular
DIN connection. The Serial DIN Cable is shown below (see page
26).
Cabling to serial printer with 6-pin DIN port
72-0158-002
DIN connector
Serial DIN Cable
Schematic
NOTE: Schematic connections are shown from END VIEW.
(As viewed from the outside of the connectors.)
Ports and connections 15
Local Area Network: RS-485 serial port
The RS-485 serial port is located on the lower left corner of the terminal. It is a 6 position 4-pin female port which will accept a male RJ-11 modular connector.
W
AND
The terminal can use RS-485 2-wire serial communication, allowing up to 32 terminals to be connected to one host port. An
RS-232 port on the host is typically used in conjunction with an
RS-232/RS-485 converter to complete the connection.
Through software, the host can communicate with individual terminals even though they are wired in parallel. RS-485 communication uses a differential bus which provides good protection from interference over long runs of up to 4000 feet.
NOTE: When wiring a network, always follow the electric wiring codes in your area. Typically, a teflon coated wire is required for wiring through the ceiling. The junction box to junction box wire shown on the opposite page is a teflon jacketed cable.
16 Ports and connections
RS-485 Serial cables
Junction Box Daisy Chain Wiring Diagram
4
5
+
+ +
3
+
2
To another
Junction Box
4
5
+
+ +
3
+
2
4
5
+
+
3
+
+
2
Junction Box Junction Box
Teflon Cable
To terminal
(short as possible)
"Standard" Modular Cable
Schematic
Junction Box
"Reversed"
Modular Cable
Schematic
DB-25 to RJ-11 Adaptor
(Adaptor C)
Schematic
RS-232 to RS-485
Converter
NOTE: Connectors are shown from
END VIEW. (As viewed from the outside of the connectors.)
To serial port on host computer
Ports and connections 17
Modem port
Terminals which are equipped with a MODEM port, will not have an RS-485 port. The MODEM port, when installed, physically replaces the RS-485 port and occupies the same location - the lower left corner of the badge terminal. It is a 6 position 4-pin female port which will accept a male RJ-11 modular connector.
W
AND
RS
MODEM
The internal modem (modulator/demodulator) converts electronic data into tones which are then transmitted over phone lines. The modem is compatible with Bell 103/212A and CCITT V.21/V.22
devices. It supports both asynchronous and synchronous (SDLC) communication and can communicate with a host computer over phone lines at 300, 1200, and 2400 baud.
18 Ports and connections
Modem cables
The cabling for modem operation is typically very simple. The modular connection uses the two inner wires of the RJ-11 jack for
tip and ring.
Connect one end of the cable to the terminal and plug the other end into your RJ-11 type modular telephone wall jack.
If a modular wall jack is not available, obtain an adaptor from your local telephone company.
“Standard” Modular Cable
Schematic
Ports and connections 19
Wand port
The Wand port is located on the lower left corner of the terminal.
It is a 6-pin DIN port which will accept a circular DIN connector.
W
AND
The Wand, when connected, uses only 3 of the 6 pins available on the DIN connection. If a Bar Code Gun (non-contact reader) is used, the center pin supplies additional power. The terminal uses
2 of the remaining pins as logic lines for external controls. See pin-out and function table below:
Pin Function
1 +5 Volts
2 Signal control logic line (special)
3 Bar Code Wand receive data
4 GND
5 Access logic line (special)
6 9 Volt unregulated
(maximum current draw 220 mA)
5
6
1
4
3
END VIEW
6-pin DIN jack
2
20 Ports and connections
Wand and Y-Cable
Disconnect power to the terminal before connecting the Bar Code
Wand. The wand is capable of reading bar code stripes by passing it directly over the label. Check the software manual to identify the codes your terminal will read.
Bar Code Wand
The Y-cable shown below allows for connection of both a wand and other external devices. The single end of the cable is plugged into the terminal. A wand can be connected to one split and another device to the other. See appendix for External Relay Box part number.
Y-cable (splitter)
Ports and connections 21
Parallel port
The parallel port is located on the right side of the Acroprint Data
Collection Terminal. It is a 25 pin female port which will accept a 25pin male connector.
This type of parallel port is typically used on IBM ® PC or IBM-PC compatible computers. The Acroprint Data Collection Terminal provides strain relief if the connector is locked in by the securing screws. Additional strain relief can be obtained by securing the parallel cable to the wall or mounting surface.
* IBM ® is a registered trademark of International Business Machines.
22 Ports and connections
Parallel cable
The parallel port is typically used for connection to a parallel printer. Shown below is a parallel interface cable. Since this is the same cable that is used to connect an IBM-PC or compatible to a printer, it will likely be available from most computer dealers offthe-shelf. One end is a male DB-25 connector, the other end is a
36-pin Centronics-type connector to match the parallel port on the printer.
Parallel Cable
Schematic
Note: Schematic connections are shown from END VIEW.
(As viewed from the outside of the connectors.)
Ports and connections 23
5. Companion products
Description/Illustration
40/80 Column
Thermal Printer
Serial Communication
Requires RS232 Serial Cable 72-0158-002
Printer
Part Number
74-0108-003 configured for 40 columns
74-0108-004 configured for 80 columns
Fingerprint Scanner Kit
Factory Installed Only
Bar Code Wand and Holder
Readers
25-0124-000
74-0106-002
External Visible 74-0111-000
Bar Code Infrared 74-0111-002
Slot Reader
Internal HID Proximity Module
Factory Installed Only
25-0126-000
24 Companion products
Description/Illustration
Lighter Power
12 VDC Adaptor
120VAC to 9VAC
Power Supply
230VAC to 9VAC
Power Supply
European
240VAC to 9VAC
Power Supply
British
230VAC to 9VAC
Power Supply
Parallel Blades
Power Supplies
Part Number
72-0160-000
56-0113-000
56-0116-000
56-0117-000
56-0118-000
External Relay Box, External Buzzer
External Relay Box 120 V 01-0121-000
240 V 01-0121-002
External Buzzer 01-0122-000
Companion products 25
Description/Illustration
Cables
Part Number
Standard Modular Cable
length - 7 feet 72-0146-000
- 50 feet 72-0146-004
Reverse Modular Cable
length - 7 feet 72-0164-000
- 50 feet 72-0164-004
Serial DIN Cable - (RS-232/printer)
72-0158-002 use with 40/80 column printer
Y-Cable (splitter) 72-0159-000
DB-25 RS-232 Host Cable Assembly
Includes DB-25 (RS-232/host) to RJ-11 female adaptor and Standard Modular Cable.
length - 7 feet 25-0116-000
- 50 feet 25-0116-007
Remote Lan Adaptor 63-0179-002
26 Companion products
Cables, Converter, Badge Racks
Description/Illustration Part Number
DB-9 RS-232 Host Cable Assembly
Includes DB-9 (RS-232/host) to RJ-11 female adaptor and Standard Modular Cable.
length - 7 feet 25-0116-004
- 50 feet 25-0116-008
Modem Adapter Cable Assembly
Includes DB-25 (modem) to RJ-11 male adaptor and Standard Modular Cable.
length - 7 feet 25-0123-000
Teflon Cable (available by the foot) 55-0124-000
Junction Box 63-0169-000
RS-232 to RS-485
Converter Assembly
Includes RS-232 to RS-485 converter,
DB-25 to RJ-11 female adaptor and
Reversed Modular Cable.
length - 7 feet 25-0121-000
40 Pocket Badge Rack (Plastic)
(8¼" wide x 22 5 /
8
high)
81-0117-000
2 -12 Pocket Badge Racks (Plastic) 81-0116-000
(3 7 /
8
" wide x 14" high)
Companion products 27
P/N 06-0262-000 Rev. B
5640 Departure Drive
Raleigh, NC 27616
919.872.5800
www.acroprint.com