book.book Page 1 Wednesday, January 20, 2010 10:20 AM

Dell™ PowerEdge™ R910

Hardware Owner’s

Manual

Regulatory Model: E06S Series

Regulatory Type: E06S001

book.book Page 2 Wednesday, January 20, 2010 10:20 AM

Notes, Cautions, and Warnings

NOTE:

A NOTE indicates important information that helps you make better use of your computer.

CAUTION:

A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.

WARNING:

A WARNING indicates a potential for property damage, personal injury, or death.

____________________

Information in this document is subject to change without notice.

© 2010 Dell Inc. All rights reserved.

Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.

Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.

Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft

Corporation in the United States and/or other countries.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

Regulatory Model: E06S Series

Regulatory Type: E06S001

January 2010 Rev. A00

book.book Page 3 Wednesday, January 20, 2010 10:20 AM

Contents

1

About Your System . . . . . . . . . . . . . . . . . .

11

Accessing System Features During Startup . . . . . . .

11

Front-Panel Features and Indicators . . . . . . . . . .

12

LCD Panel Features . . . . . . . . . . . . . . . . . . .

14

Home Screen . . . . . . . . . . . . . . . . . . . .

15

Setup Menu . . . . . . . . . . . . . . . . . . . . .

16

View Menu . . . . . . . . . . . . . . . . . . . . .

17

Hard-Drive Indicator Patterns . . . . . . . . . . . . . .

18

Back-Panel Features and Indicators . . . . . . . . . .

19

Guidelines for Connecting External Devices . . . . . .

21

NIC Indicator Codes . . . . . . . . . . . . . . . . . . .

21

Power Indicator Codes . . . . . . . . . . . . . . . . .

22

LCD Status Messages . . . . . . . . . . . . . . . . . .

23

Viewing Status Messages . . . . . . . . . . . . .

23

Removing LCD Status Messages . . . . . . . . . .

24

System Messages . . . . . . . . . . . . . . . . . . . .

41

Warning Messages . . . . . . . . . . . . . . . . . . .

60

Diagnostics Messages . . . . . . . . . . . . . . . . .

60

Alert Messages . . . . . . . . . . . . . . . . . . . . .

60

Contents

3

book.book Page 4 Wednesday, January 20, 2010 10:20 AM

4

Other Information You May Need . . . . . . . . . . . .

60

2

Using the System Setup Program and

UEFI Boot Manager

. . . . . . . . . . . . . . . . . 63

Choosing the System Boot Mode . . . . . . . . . . . .

63

Entering the System Setup Program . . . . . . . . . . .

64

Responding to Error Messages . . . . . . . . . . .

64

Using the System Setup Program Navigation

Keys . . . . . . . . . . . . . . . . . . . . . . . . .

64

System Setup Options . . . . . . . . . . . . . . . . . .

65

Main Screen . . . . . . . . . . . . . . . . . . . .

65

Memory Settings Screen . . . . . . . . . . . . . .

67

Processor Settings Screen . . . . . . . . . . . . .

68

SATA Settings Screen . . . . . . . . . . . . . . . .

69

Boot Settings Screen . . . . . . . . . . . . . . . .

69

Integrated Devices Screen . . . . . . . . . . . . .

70

PCI IRQ Assignments Screen . . . . . . . . . . . .

71

Serial Communication Screen . . . . . . . . . . .

72

Embedded Server Management Screen . . . . . .

73

Power Management Screen . . . . . . . . . . . .

73

System Security Screen . . . . . . . . . . . . . .

74

Exit Screen . . . . . . . . . . . . . . . . . . . . .

76

Entering the UEFI Boot Manager . . . . . . . . . . . . .

76

Using the UEFI Boot Manager Navigation Keys . .

77

UEFI Boot Manager Screen . . . . . . . . . . . . .

77

UEFI Boot Settings Screen . . . . . . . . . . . . .

78

System Utilities Screen . . . . . . . . . . . . . . .

78

System and Setup Password Features . . . . . . . . . .

79

Using the System Password . . . . . . . . . . . .

79

Using the Setup Password . . . . . . . . . . . . .

81

Contents

book.book Page 5 Wednesday, January 20, 2010 10:20 AM

Embedded System Management . . . . . . . . . . . .

82

iDRAC Configuration Utility . . . . . . . . . . . . . . .

83

Entering the iDRAC Configuration Utility . . . . . .

83

3

Installing System Components . . . . . . . .

85

Recommended Tools . . . . . . . . . . . . . . . . . . .

85

Inside the System . . . . . . . . . . . . . . . . . . . .

85

Front Bezel (Optional) . . . . . . . . . . . . . . . . . .

87

Removing the Front Bezel . . . . . . . . . . . . .

87

Installing the Front Bezel . . . . . . . . . . . . . .

87

System Identification Panel . . . . . . . . . . . . . . .

88

Removing the System Identification Panel . . . . .

88

Installing the System Identification Panel . . . . .

89

Opening and Closing the System . . . . . . . . . . . .

89

Opening the System . . . . . . . . . . . . . . . .

89

Closing the System . . . . . . . . . . . . . . . . .

90

System Memory . . . . . . . . . . . . . . . . . . . . .

91

General Memory Module Installation

Guidelines . . . . . . . . . . . . . . . . . . . . . .

92

Removing a Memory-Riser Blank . . . . . . . . .

99

Installing a Memory-Riser Blank . . . . . . . . . .

100

Removing a Memory Riser . . . . . . . . . . . . .

100

Installing a Memory Riser . . . . . . . . . . . . .

101

Installing Memory Modules . . . . . . . . . . . .

102

Removing Memory Modules . . . . . . . . . . . .

105

Removing the Memory-Riser Guide . . . . . . . .

106

Installing the Memory-Riser Guide . . . . . . . . .

107

Contents

5

book.book Page 6 Wednesday, January 20, 2010 10:20 AM

6

Contents

Hard Drives . . . . . . . . . . . . . . . . . . . . . . .

107

Removing a Hard-Drive Blank . . . . . . . . . .

108

Installing a Hard-Drive Blank . . . . . . . . . . .

108

Removing a Hard Drive . . . . . . . . . . . . . .

109

Installing a Hard Drive . . . . . . . . . . . . . .

110

Removing a Hard Drive From a Hard-Drive

Carrier . . . . . . . . . . . . . . . . . . . . . . .

112

Installing a Hard Drive Into a Drive Carrier . . . .

113

Optical Drive . . . . . . . . . . . . . . . . . . . . . .

113

Removing an Optical Drive . . . . . . . . . . . .

113

Installing an Optical Drive . . . . . . . . . . . .

115

Cooling Fans . . . . . . . . . . . . . . . . . . . . . .

116

Removing a Cooling Fan . . . . . . . . . . . . .

116

Installing a Cooling Fan . . . . . . . . . . . . . .

117

Removing the Cooling Fan Assembly . . . . . . .

118

Installing the Cooling Fan Assembly . . . . . . .

120

Internal USB Memory Key . . . . . . . . . . . . . . .

120

Integrated NIC Hardware Key . . . . . . . . . . . . .

123

Expansion Cards and Expansion-Card Riser . . . . .

124

Expansion Card Installation Guidelines . . . . . .

124

Installing an Expansion Card . . . . . . . . . . .

126

Removing an Expansion Card . . . . . . . . . . .

128

Installing an Expansion-Card Riser . . . . . . . .

129

Removing an Expansion-Card Riser . . . . . . .

133

I/O Card . . . . . . . . . . . . . . . . . . . . . . . . .

134

Removing the I/O Card . . . . . . . . . . . . . .

134

Installing the I/O Card . . . . . . . . . . . . . . .

135

book.book Page 7 Wednesday, January 20, 2010 10:20 AM iDRAC6 Enterprise Card (Optional) . . . . . . . . . . . 136

Installing an iDRAC6 Enterprise Card . . . . . . .

136

Removing an iDRAC6 Enterprise Card . . . . . . .

138

VFlash Media (Optional) . . . . . . . . . . . . . . . . .

139

Installing a VFlash Media Card . . . . . . . . . . .

139

Removing a VFlash Media Card . . . . . . . . . .

139

Internal Dual SD Module (Optional) . . . . . . . . . . .

139

Removing the Internal Dual SD Module . . . . . .

139

Installing the Internal Dual SD Module . . . . . . .

141

Internal SD Card (Optional) . . . . . . . . . . . . . . .

142

Installing an Internal SD Card . . . . . . . . . . .

142

Removing an Internal SD Card . . . . . . . . . . .

142

Integrated Storage Controller Card . . . . . . . . . . .

143

Removing the Integrated Storage

Controller Card . . . . . . . . . . . . . . . . . . .

143

Installing the Integrated Storage

Controller Card . . . . . . . . . . . . . . . . . . .

145

RAID Battery . . . . . . . . . . . . . . . . . . . . . . .

146

Removing a RAID Battery . . . . . . . . . . . . . .

146

Installing the RAID Battery . . . . . . . . . . . . .

147

Processors . . . . . . . . . . . . . . . . . . . . . . . .

148

Removing a Processor . . . . . . . . . . . . . . .

148

Installing a Processor . . . . . . . . . . . . . . .

152

Power Supplies . . . . . . . . . . . . . . . . . . . . .

154

Removing a Power Supply . . . . . . . . . . . . .

155

Installing a Power Supply . . . . . . . . . . . . .

156

Removing the Power Supply Blank . . . . . . . . .

157

Installing the Power Supply Blank . . . . . . . . .

157

Contents

7

book.book Page 8 Wednesday, January 20, 2010 10:20 AM

System Battery . . . . . . . . . . . . . . . . . . . . .

157

Replacing the System Battery . . . . . . . . . .

157

SAS Backplane . . . . . . . . . . . . . . . . . . . . .

159

Removing the SAS Backplane . . . . . . . . . .

159

Installing the SAS Backplane . . . . . . . . . . .

161

Power Distribution Board . . . . . . . . . . . . . . .

161

Removing the Power Distribution Board . . . . .

161

Replacing the Power Distribution Board . . . . .

163

Control Panel Assembly . . . . . . . . . . . . . . . .

163

Removing the Control Panel Display Module . . .

163

Installing the Control Panel Display Module . . .

164

Removing the Control Panel Board . . . . . . . .

166

Installing the Control Panel Board . . . . . . . .

167

System Board . . . . . . . . . . . . . . . . . . . . . .

168

Removing the System Board . . . . . . . . . . .

168

Installing the System Board . . . . . . . . . . . .

170

4

Troubleshooting Your System . . . . . . . .

173

Safety First—For You and Your System . . . . . . . .

173

Troubleshooting System Startup Failure . . . . . . . .

173

Troubleshooting External Connections . . . . . . . .

173

Troubleshooting the Video Subsystem . . . . . . . . .

174

Troubleshooting a USB Device . . . . . . . . . . . .

174

Troubleshooting a Serial I/O Device . . . . . . . . . .

175

Troubleshooting a NIC . . . . . . . . . . . . . . . . .

175

8

Contents

book.book Page 9 Wednesday, January 20, 2010 10:20 AM

Troubleshooting a Wet System . . . . . . . . . . . . .

176

Troubleshooting a Damaged System . . . . . . . . . .

177

Troubleshooting the System Battery . . . . . . . . . . .

178

Troubleshooting Power Supplies . . . . . . . . . . . .

179

Troubleshooting System Cooling Problems . . . . . . .

180

Troubleshooting a Fan . . . . . . . . . . . . . . .

180

Troubleshooting System Memory . . . . . . . . . . . .

181

Troubleshooting an Internal USB Key . . . . . . . . . .

183

Troubleshooting an Internal SD Card . . . . . . . . . .

184

Troubleshooting an Optical Drive . . . . . . . . . . . .

185

Troubleshooting a Tape Backup Unit . . . . . . . . . .

186

Troubleshooting a Hard Drive . . . . . . . . . . . . . .

186

Troubleshooting a Storage Controller . . . . . . . . . .

187

Troubleshooting Expansion Cards . . . . . . . . . . . .

189

Troubleshooting the Processors . . . . . . . . . . . . .

190

5

Running the System Diagnostics . . . . . .

193

Using Online Diagnostics . . . . . . . . . . . . . . . .

193

Embedded System Diagnostics Features . . . . . . . .

193

When to Use the Embedded System Diagnostics . . . .

194

Running the Embedded System Diagnostics . . . . . .

194

System Diagnostics Testing Options . . . . . . . . . .

194

Contents

9

book.book Page 10 Wednesday, January 20, 2010 10:20 AM

Using the Custom Test Options . . . . . . . . . . . .

195

Selecting Devices for Testing . . . . . . . . . . .

195

Selecting Diagnostics Options . . . . . . . . . .

195

Viewing Information and Results . . . . . . . . .

196

6

Jumpers and Connectors . . . . . . . . . . . .

197

System Board Jumper . . . . . . . . . . . . . . . . .

197

System Board Connectors . . . . . . . . . . . . . . .

198

SAS Backplane Board Connectors . . . . . . . . . .

200

Disabling a Forgotten Password . . . . . . . . . . . .

201

7

Getting Help . . . . . . . . . . . . . . . . . . . . . .

203

Contacting Dell . . . . . . . . . . . . . . . . . . . . .

203

Index

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205

10

Contents

book.book Page 11 Wednesday, January 20, 2010 10:20 AM

About Your System

Accessing System Features During Startup

The following keystrokes provide access to system features during startup.

Keystroke Description

<F2>

<F10>

Enters the System Setup program. See "Using the System Setup

Program and UEFI Boot Manager" on page 63.

Enters System Services, which opens the Lifecycle Controller. The

Lifecycle Controller allows you to access utilities such as embedded system diagnostics. For more information, see the Lifecycle Controller documentation.

<F11> Enters the BIOS Boot Manager or the UEFI Boot Manager,

depending on the system's boot configuration. See "Using the System

Setup Program and UEFI Boot Manager" on page 63.

Starts PXE boot.

<F12>

<Ctrl><E> Enters the iDRAC Configuration Utility, which allows access to the

System Event Log (SEL) and configuration of remote access to the system. For more information, see the iDRAC user documentation.

<Ctrl><C> Enters the SAS Configuration Utility. For more information, see the

SAS adapter documentation.

<Ctrl><R> Enters the PERC configuration utility. For more information, see the

PERC card documentation

<Ctrl><S> Enters the utility to configure NIC settings for PXE boot. For more information, see the documentation for your integrated NIC.

About Your System

11

book.book Page 12 Wednesday, January 20, 2010 10:20 AM

Front-Panel Features and Indicators

Figure 1-1.

Front-Panel Features and Indicators

1 2 3 4 5 6 7 8 9 10

12

Item Indicator, Button, or

Connector

1 Optical drive

(optional)

Icon

2 Power-on indicator, power button

Description

One optional slim-line SATA

DVD-ROM drive or DVD-RW drive.

NOTE:

DVD devices are data only.

The power-on indicator lights when the system power is on.

The power button controls the DC power supply output to the system.

When the system bezel is installed, the power button is not accessible.

NOTE:

When powering on the system, the video monitor can take from several seconds to over two minutes to display an image, depending on the amount of memory installed in the system.

NOTE:

On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off.

About Your System

book.book Page 13 Wednesday, January 20, 2010 10:20 AM

Item Indicator, Button, or

Connector

3 NMI button

Icon

6

7

4

5

USB connectors (2)

Video connector

LCD menu buttons

LCD panel

8 System identification button

Description

Used to troubleshoot software and device driver errors when using certain operating systems. This button can be pressed using the end of a paper clip.

Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.

Connect USB devices to the system. The ports are USB 2.0-compliant.

Connects a monitor to the system.

Allows you to navigate the control panel

LCD menu.

Provides system ID, status information, and system error messages.

The LCD lights blue during normal system operation. The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text.

NOTE:

If the system is connected to AC power and an error has been detected, the LCD lights amber regardless of whether the system has been powered on.

The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pushed, the LCD panel on the front and the blue system status indicator on the back blink until one of the buttons is pushed again.

About Your System

13

book.book Page 14 Wednesday, January 20, 2010 10:20 AM

Item Indicator, Button, or

Connector

9 System identification panel

Icon

10 Hard drives

Description

A slide-out panel for system information including the Express Service tag, embedded NIC MAC address, and iDRAC6 Enterprise card MAC address.

Space is provided for an additional label.

Up to sixteen 2.5-inch, external hot-swappable SAS or SSD hard drives.

NOTE:

Only one SATA drive is supported on the x4 backplane. SAS and SATA hard disks on the same backplane cannot be combined into a single virtual disk. x16 backplanes do not support SATA drives.

LCD Panel Features

The system's LCD panel provides system information and status and error messages to signify when the system is operating correctly or when the system

needs attention. See "LCD Status Messages" on page 23 for information

about specific status codes.

The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error condition. When the system is in standby mode, the LCD backlight is off and can be turned on by pressing either the Select,

Left or Right button on the LCD panel. The LCD backlight will remain off if

LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools.

14

About Your System

book.book Page 15 Wednesday, January 20, 2010 10:20 AM

Figure 1-2.

LCD Panel Features

1 2 3 4

Item

1

2

3

4

Buttons Description

Left

Select

Right

Moves the cursor back in one-step increments.

Selects the menu item highlighted by the cursor.

Moves the cursor forward in one-step increments.

During message scrolling:

• Press once to increase scrolling speed.

• Press again to stop.

• Press again to return to default scrolling speed.

• Press again to repeat the cycle.

System identification Turns the system ID mode on (LCD panel flashes blue) and off.

Press quickly to toggle the system ID on and off. If the system hangs during POST, press and hold the system ID button for more than five seconds to enter BIOS Progress mode.

Home Screen

The Home screen displays user-configurable information about the system.

This screen is displayed during normal system operation when there are no status messages or errors present. When the system is in standby mode, the

LCD backlight will turn off after five minutes of inactivity if there are no error messages. Press one of the three navigation buttons (Select, Left, or Right) to view the Home screen.

About Your System

15

book.book Page 16 Wednesday, January 20, 2010 10:20 AM

To navigate to the Home screen from another menu, continue to select the up arrow until the Home icon is displayed, and then select the Home icon.

From the Home screen, press the Select button to enter the main menu. See the following tables for information on the Setup and View submenus.

Setup Menu

NOTE:

When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.

Option

DRAC

Set error

Set home

Description

Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields are IP,

Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two separate DNS entries are available.

Select SEL to display LCD error messages in a format that matches the IPMI description in the SEL. This can be useful when trying to match an LCD message with an SEL entry.

Select Simple to display LCD error messages in a

simplified user-friendly description. See "LCD Status

Messages" on page 23 for a list of messages in this

format.

Select the default information to be displayed on the

LCD Home screen. See "View Menu" on page 17 to see

the options and option items that can be set as the default on the Home screen.

16

About Your System

book.book Page 17 Wednesday, January 20, 2010 10:20 AM

View Menu

Option

DRAC IP

MAC

Name

Number

Power

Temperature

Description

Displays the IPv4 or IPv6 addresses for the iDRAC6.

Addresses include DNS (Primary and Secondary),

Gateway, IP, and Subnet (IPv6 does not have Subnet).

Displays the MAC addresses for DRAC, iSCSIn, or

NETn.

Displays the name of the Host, Model, or User String for the system.

Displays the Asset tag or the Service tag for the system.

Displays the power output of the system in BTU/hr or

Watts. The display format can be configured in the Set

home submenu of the Setup menu. See "Setup Menu" on page 16.

Displays the temperature of the system in Celsius or

Fahrenheit. The display format can be configured in the

Set home submenu of the Setup menu. See "Setup

Menu" on page 16.

About Your System

17

book.book Page 18 Wednesday, January 20, 2010 10:20 AM

Hard-Drive Indicator Patterns

1

2

18

1 hard-drive activity indicator (green) 2 hard-drive status indicator (green and amber)

Drive-Status Indicator Pattern (RAID Only) Condition

Blinks green two times per second

Off

Identify drive/preparing for removal

Drive ready for insertion or removal

NOTE:

The drive status indicator remains off until all hard drives are initialized after system power is applied. Drives are not ready for insertion or removal during this time.

Blinks green, amber, and off Drive predicted failure

About Your System

book.book Page 19 Wednesday, January 20, 2010 10:20 AM

Drive-Status Indicator Pattern (RAID Only) Condition

Blinks amber four times per second

Blinks green slowly

Steady green

Blinks green three seconds, amber three seconds, and off six seconds

Drive failed

Drive rebuilding

Drive online

Rebuild aborted

Back-Panel Features and Indicators

Figure 1-3.

Back-Panel Features and Indicators

1 2 3 4 5 6

10 9 8 7

Item Indicator, Button, or

Connector

1 Ethernet or SFP+ connectors

Icon Description

Depending on the configuration, your system may have either a 1 GbE I/O riser or a 10 Gb I/O riser.

A 1 GbE I/O riser consists of four

Ethernet connectors and a 10 Gb I/O riser consists of two SFP+ and two

Ethernet connectors.

About Your System

19

book.book Page 20 Wednesday, January 20, 2010 10:20 AM

20

3

4

Item Indicator, Button, or

Connector

2 VFlash media slot

(optional)

Icon

5

USB connectors (2) iDRAC6 Enterprise port (optional)

PCIe expansion card slots (7)

6

7

8

Power supplies (4)

System identification connector

System identification button

Description

Connects an external SD memory card for the optional iDRAC6 Enterprise card.

Connect USB devices to the system. The ports are USB 2.0-compliant.

Dedicated management port for the optional iDRAC6 Enterprise card.

PCI Express Generation 1 and

Generation 2

Slot 1: PCIe x4 Gen2 half-length, full height

Slot 2–4: PCIe x8 Gen2 half-length, full height

Slot 5: PCIe x4 Gen1 half-length, full height

Slot 6: PCIe x8 Gen2 half-length, full height

Slot 7: PCIe x16 Gen2 half-length, half height

NOTE:

Slot 7 can be expanded to four additional PCIe x4 Gen2 low profile slots using an optional PCIe expansion riser.

1100 W or 750 W

Connects the optional system status indicator assembly through the optional cable management arm.

The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pushed, the LCD panel on the front and the blue system status indicator on the back blink until one of the buttons is pushed again.

About Your System

book.book Page 21 Wednesday, January 20, 2010 10:20 AM

Item Indicator, Button, or

Connector

9 Serial connector

Icon

10 Video connector

Description

Connects a serial device to the system.

Connects a VGA display to the system.

Guidelines for Connecting External Devices

• Turn off power to the system and external devices before attaching a new external device. Turn on any external devices before turning on the system

(unless the documentation for the device specifies otherwise).

• Ensure that the appropriate driver for the attached device has been installed on the system.

If necessary to enable ports on your system, use the "Using the System

Setup Program and UEFI Boot Manager" on page 63.

NIC Indicator Codes

1

2

1 link indicator 2 activity indicator

Indicator

Link and activity indicators are off

Link indicator is green

Indicator Code

The NIC is not connected to the network.

The NIC is connected to a valid network link at

1000 Mbps.

About Your System

21

book.book Page 22 Wednesday, January 20, 2010 10:20 AM

Indicator Indicator Code

Link indicator is amber The NIC is connected to a valid network link at

10/100 Mbps.

Activity indicator is green blinking

Network data is being sent or received.

Power Indicator Codes

The power supplies have indicators that show whether power is present or whether a power fault has occurred.

• Not lit — AC power is not connected.

• Green — In standby mode, a green light indicates that a valid AC source is connected to the power supply and that the power supply is operational.

When the system is on, a green light also indicates that the power supply is providing DC power to the system.

• Amber — Indicates a problem with the power supply.

• Alternating green and amber — When hot-adding a power supply, this indicates that the power supply is mismatched with the other power supply (a high output power supply and an energy smart power supply are installed in the same system). Replace the power supply that has the flashing indicator with a power supply that matches the capacity of the other installed power supply.

CAUTION:

When correcting a power supply mismatch, replace only the power supply with the flashing indicator. Swapping the opposite power supply to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to an Energy Smart configuration or vice versa, you must power down the system.

22

About Your System

book.book Page 23 Wednesday, January 20, 2010 10:20 AM

Figure 1-4.

Power Supply Status Indicator

1

2

1 Velcro strap 2 power supply status indicator

LCD Status Messages

The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management software documentation.

NOTE:

If your system fails to boot, press the System ID button for at least 5 seconds

until an error code appears on the LCD. Record the code, then see "Getting Help" on page 203.

Viewing Status Messages

If a system error occurs, the LCD screen will turn amber. Press the Select button to view the list of errors or status messages. Use the left and right buttons to highlight an error number, and press Select to view the error.

About Your System

23

book.book Page 24 Wednesday, January 20, 2010 10:20 AM

Removing LCD Status Messages

For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a normal state. For other faults, you must take action to remove the message from the display:

• Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.

• Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately 10 seconds, reconnect the power cable, and restart the system.

NOTE:

The following LCD status messages are displayed in the simple format. See

"Setup Menu" on page 16 to select the format in which the messages are displayed.

Table 1-1.

LCD Status Messages

Code

E1000

Text

Failsafe voltage error.

Contact support.

Causes

Check the SEL for critical failure events.

Corrective Actions

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

See "Troubleshooting

System Cooling

Problems" on page 180.

E1114 Ambient Temp exceeds allowed

Ambient temperature has reached a point outside of the allowed range.

range.

E1116 Memory disabled, temp above range. Power cycle AC.

Memory has exceeded allowable temperature and has been disabled to prevent damage to the components.

Remove AC power to the system for 10 seconds and restart the system.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on page 203.

24

About Your System

book.book Page 25 Wednesday, January 20, 2010 10:20 AM

Code Text Causes

E1119 Chipset # temp out of range. Check

Chipset temperature has reached a point outside of the allowed range.

motherboard heatsinks.

Corrective Actions

See "Troubleshooting

System Cooling

Problems" on page 180.

E1120 CPU VCORE

Temp: "CPU

VCORE

Regulator temp exceeding range. Check fans".

The regulator temperature has reached a point outside of the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 180.

E1121 CPU VCACHE

Temp: "CPU

VCACHE

Regulator temp exceeding range. Check fans".

The regulator temperature has reached a point outside of the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 180.

E1122 Mem VR Temp :

"Mem Voltage

Regulator

The regulator temperature has reached a point outside of the allowed range.

temp exceeding range. Check fans".

See "Troubleshooting

System Cooling

Problems" on page 180.

E1210 Motherboard battery failure.

Check battery.

CMOS battery is missing or the voltage is outside of the allowable range.

See "Troubleshooting the

System Battery" on page 178.

About Your System

25

book.book Page 26 Wednesday, January 20, 2010 10:20 AM

26

Code

E1211

E1216

Text

RAID

Controller battery failure.

Check battery.

3.3V

Regulator failure.

Reseat PCIe cards.

Causes Corrective Actions

RAID battery is either missing, bad, or unable to recharge due to thermal issues.

Reseat the RAID battery

connector. See "Installing the RAID Battery" on page 147 and

"Troubleshooting System

Cooling Problems" on page 180.

3.3V voltage regulator failed. Remove and reseat the

PCIe expansion cards. If the problem persists, see

"Troubleshooting

Expansion Cards" on page 189.

Storage backplane voltage regulator has failed.

Remove and reseat the backplane. If the problem

persists, see "Getting

Help" on page 203.

E1219 Disk

Backplane power failure.

Check BP power cable.

E1222 CPU # VCACHE

Regulator failure.

Contact support.

Processor voltage regulator failed.

Reseat the processor(s).

See "Troubleshooting the

Processors" on page 190.

If the problem persists,

see "Getting Help" on page 203.

E122C CPU Power

Fault. Power cycle AC.

A power fault was detected when powering up the processor(s).

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E122E On-board regulator failed. Call support.

One of the on-board voltage regulators failed.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

About Your System

book.book Page 27 Wednesday, January 20, 2010 10:20 AM

Code Text

E1233 IO Riser power failure.

Reseat IO

Riser.

Causes

IO riser voltage regulator failed.

E1234 Memory Riser

# power failure.

Memory riser voltage regulator failed.

Reseat riser and DIMMs.

E1243 CPU # VCORE

Regulator failure.

Contact

Support.

Processor voltage regulator failed.

Corrective Actions

Reseat the I/O riser.

If the problem persists,

see "Getting Help" on page 203.

Reseat the memory riser.

If the problem persists,

see "Getting Help" on page 203.

E1244 Embedded 10Gb Insufficient standby power

NICs for 10 Gb embedded NICs.

disabled.

Check or add

PSUs.

E1245

E1310

CPU # VIO

Regulator failure.

Contact support.

Fan ## RPM exceeding range. Check fan.

Processor voltage regulator failed.

RPM of specified fan is outside of the intended operating range.

Reseat the processor. See

"Troubleshooting the

Processors" on page 190.

If the problem persists,

see "Getting Help" on page 203.

Reseat the power supplies.

See "Troubleshooting

Power Supplies" on page 179.

If the problem persists,

see "Getting Help" on page 203.

Reseat the processor. See

"Troubleshooting the

Processors" on page 190.

If the problem persists,

see "Getting Help" on page 203.

See "Troubleshooting

System Cooling

Problems" on page 180.

About Your System

27

book.book Page 28 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

E1313 Fan redundancy lost. Check fans.

E1314 Critical system cooling loss.

Check fans.

The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.

Check LCD for additional scrolling messages. See

"Troubleshooting a Fan" on page 180.

All fans have been removed from system.

Ensure that the fans are properly installed. See

"Troubleshooting a Fan" on page 180.

E1410 System Fatal

Error detected.

A fatal system error has been detected.

Check LCD for additional scrolling messages.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1414 CPU # temp exceeding range. Check

CPU heatsink.

Specified processor is out of acceptable temperature range.

Ensure that the processor heat sinks are properly installed. See

"Troubleshooting the

Processors" on page 190

and "Troubleshooting

System Cooling

Problems" on page 180.

E1418 CPU # not detected.

Check CPU is seated properly.

Specified processor is missing or bad, and the system is in an unsupported configuration.

Ensure that the specified processor is properly installed. See

"Troubleshooting the

Processors" on page 190.

E141C Unsupported

CPU configuration. Check

CPU or BIOS revision.

Processors are in an unsupported configuration.

Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system’s

Getting Started Guide.

28

About Your System

book.book Page 29 Wednesday, January 20, 2010 10:20 AM

Code Text Causes

E1614 Power Supply

# (### W) error. Check

Specified power supply failed.

power supply.

Corrective Actions

E141F CPU # protocol error. Power

The system BIOS reported a processor protocol error.

cycle AC.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1420 CPU Bus parity error.

The system BIOS reported a processor bus parity error.

Power cycle

AC.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1421 CPU # initializati on error.

Power cycle

AC.

The system BIOS reported a processor initialization error.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1422 CPU # machine check error.

The system BIOS reported a machine check error.

Power cycle

AC.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1610 Power Supply

# (### W) missing.

Specified power supply was removed or is missing from the system.

Check power supply.

See "Troubleshooting

Power Supplies" on page 179.

See "Troubleshooting

Power Supplies" on page 179.

About Your System

29

book.book Page 30 Wednesday, January 20, 2010 10:20 AM

30

Code Text Causes Corrective Actions

E1618 Predictive failure on

Power Supply

# (### W).

Check PSU.

A power supply fan failure, an over-temperature condition, or power supply communication error has caused the predictive warning of an impending power supply failure.

See "Troubleshooting

Power Supplies" on page 179.

E161C Power Supply

# (### W) lost AC

Specified power supply is attached to the system, but it has lost its AC input.

power. Check

PSU cables.

Check the AC power source for the specified power supply. If the problem persists, see

"Troubleshooting Power

Supplies" on page 179.

E1620 Power Supply

# (### W) AC power error.

Check PSU cables.

Specified power supply's AC input is outside of the allowable range.

Check the AC power source for the specified power supply. If the problem persists, see

"Troubleshooting Power

Supplies" on page 179.

E1624

E1626 Power Supply

Mismatch.

PSU1 = ### W,

The power supplies in the system are not the same wattage.

PSU2 = ### W.

E1629

Lost power supply redundancy.

Check PSU cables.

Power required >

PSU wattage.

Check PSU and config.

The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down.

See "Troubleshooting

Power Supplies" on page 179.

The system configuration requires more power than the power supplies can provide, even with throttling.

Ensure that power supplies with matching wattage are installed. See the Technical

Specifications outlined in your system’s Getting

Started Guide.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.

About Your System

book.book Page 31 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

E1631 System power The processors and memory draw exceeded throttling is not sufficient to threshold. keep system power

Contact support.

consumption below the maximum safe level with current power supply configuration.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1632 PowerSafe event.

Contact support.

The processors and memory have been throttled to keep system power consumption below the maximum safe level with current power supply configuration.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1710 I/O channel check error.

The system BIOS reported an I/O channel check.

Review & clear SEL.

Check the SEL for more information and then clear the SEL. Remove

AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1711 PCI parity error on Bus

## Device ##

Function ##.

The system BIOS reported a

PCI parity error on a component that resides in

PCI configuration space at bus ##, device ##, function ##.

Remove and reseat the

PCIe expansion cards. If the problem persists, see

"Troubleshooting

Expansion Cards" on page 189.

PCI parity error on Slot

#. Review & clear SEL.

The system BIOS reported a

PCI parity error on a component that resides in the specified slot.

Remove and reseat the

PCIe expansion cards. If the problem persists, see

"Troubleshooting

Expansion Cards" on page 189.

About Your System

31

book.book Page 32 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

E1712 PCI system error on Bus

## Device ##

Function ##.

The system BIOS reported a

PCI system error on a component that resides in

PCI configuration space at bus ##, device ##, function ##.

Remove and reseat the

PCIe expansion cards. If the problem persists, see

"Troubleshooting

Expansion Cards" on page 189.

PCI system error on Slot

#. Review & clear SEL.

The system BIOS reported a

PCI system error on a component that resides in the specified slot.

Reinstall the expansion-

card riser. See "Expansion

Cards and Expansion-

Card Riser" on page 124.

If the problem persists, the riser card or system board is faulty. See

"Getting Help" on page 203.

E1714 Unknown error. Review

The system BIOS determined there has been

& clear SEL.

an error in the system, but is unable to determine its origin.

Check the SEL for more information and then clear the SEL. Remove

AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1715 Fatal I/O

Error. Review

& clear SEL.

The system BIOS determined there has been a fatal error in the system.

Check the SEL for more information, and then clear the SEL. Remove

AC power to the system for 10 seconds, and restart the system.

If the problem persists,

see "Getting Help" on page 203.

32

About Your System

book.book Page 33 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

E1716 Chipset IERR

Bus ## Dev ##

Function

Review &

##.

The system BIOS reported a chipset internal error that resides in bus ##, device

##, function ##.

clear SEL.

Check the SEL for more information, and then clear the SEL. Remove

AC power to the system for 10 seconds, and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E1717 CPU #

& clear SEL.

The system BIOS internal error. Review determined that the specified processor has had an internal error.

Check the SEL for more information, and then clear the SEL. Remove

AC power to the system for 10 seconds, and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E171F PCIe fatal error on Bus

## Device ##

Function ##.

The system BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.

Remove and reseat the

PCIe expansion cards. If the problem persists, see

"Troubleshooting

Expansion Cards" on page 189.

PCIe fatal error on Slot

#. Review & clear SEL.

The system BIOS has reported a PCIe fatal error on a component that resides in the specified slot.

Reinstall the expansion-

card riser. See "Expansion

Cards and Expansion-

Card Riser" on page 124.

If the problem persists, the riser card or system board is faulty. See

"Getting Help" on page 203.

E1810 Hard drive ## fault. Review

The specified hard drive experienced a fault.

& clear SEL.

See "Troubleshooting a

Hard Drive" on page 186.

About Your System

33

book.book Page 34 Wednesday, January 20, 2010 10:20 AM

Code Text

E1A14 SAS cable A failure.

Check connection.

Causes

SAS cable A is missing or bad.

Corrective Actions

E1812 Hard drive ## removed.

Check drive.

The specified hard drive has been removed from the system.

Information only.

E1813 Internal Dual The internal dual SD

SD Module module card has failed.

Card # failed. Check

SD card.

Reseat the internal dual

SD module card.

If the problem persists,

see "Getting Help" on page 203.

E1814 Internal SD

Module Card # writeprotected.

Check SD

The internal dual SD module card is writeprotected and cannot be used.

card.

Change the write-protect switch setting on SD card.

E1815 Internal Dual

SD Module redundancy

The internal dual SD module bootable media is no longer redundant.

lost. Check

SD cards.

Initiate a rebuild on the next POST execution.

Reseat the internal dual

SD module card. See

"Removing an Internal SD

Card" on page 142 and

"Installing an Internal SD

Card" on page 142.

If the problem persists,

see "Getting Help" on page 203.

Reseat the cable. If the problem persists, replace cable.

If the problem persists,

see "Getting Help" on page 203.

34

About Your System

book.book Page 35 Wednesday, January 20, 2010 10:20 AM

Code Text Causes

E2013 BIOS unable The system BIOS failed to to shadow memory. Check copy its flash image into memory.

DIMMs.

Corrective Actions

E1A15 SAS cable B failure.

Check connection.

SAS cable B is missing or bad.

Reseat the cable. If the problem persists, replace cable.

If the problem persists,

see "Getting Help" on page 203

E1A1D Control panel USB cable to the control

USB cable not panel is missing or bad.

E2010 detected.

Check cable.

Memory not detected.

Inspect

DIMMs.

Reseat the cable. If the problem persists, replace cable.

If the problem persists,

see "Getting Help" on page 203.

No memory was detected in the system.

Install memory or reseat the memory risers and memory modules. See

"Installing a Memory

Riser" on page 101,

"Installing Memory

Modules" on page 102 or

"Troubleshooting System

Memory" on page 181.

E2011 Memory configuratio n failure.

Check DIMMs.

Memory detected, but is not configurable. Error detected during memory configuration.

See "Troubleshooting

System Memory" on page 181.

E2012 Memory configured but unusable.

Check DIMMs.

Memory configured, but is unusable.

See "Troubleshooting

System Memory" on page 181.

See "Troubleshooting

System Memory" on page 181.

About Your System

35

book.book Page 36 Wednesday, January 20, 2010 10:20 AM

36

Code Text Causes Corrective Actions

E2014 CMOS RAM failure.

Power cycle

AC.

CMOS failure. CMOS RAM not functioning properly.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E2015

E2016

DMA

Controller failure.

Power cycle

AC.

Interrupt

Controller failure.

Power cycle

AC.

DMA controller failure.

Interrupt controller failure.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E2017 Timer refresh Timer refresh failure.

failure.

Power cycle

AC.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E2018 Programmable

Timer error.

Power cycle

Programmable interval timer error.

AC.

E2019 Parity error.

Power cycle

AC.

Parity error.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

About Your System

book.book Page 37 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

E201A SuperIO failure.

Power cycle

AC.

SIO failure.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E201B Keyboard

Controller error. Power cycle AC.

Keyboard controller failure. Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E201C SMI initializati on failure.

Power cycle

AC.

System management interrupt (SMI) initialization failure.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Getting Help" on page 203.

E201D Shutdown test BIOS shutdown test failure. Remove AC power to the failure. system for 10 seconds and

Power cycle restart the system.

AC.

If the problem persists,

see "Getting Help" on page 203.

E201E POST memory BIOS POST memory test test failure. failure.

Check DIMMs.

See "Troubleshooting

System Memory" on page 181.

If the problem persists,

see "Getting Help" on page 203.

E2020 CPU configuratio n failure.

Check screen message.

Processor configuration failure.

Check screen for specific error messages. See

"Troubleshooting the

Processors" on page 190.

About Your System

37

book.book Page 38 Wednesday, January 20, 2010 10:20 AM

Code Text Causes

E2021 Incorrect memory configuration. Review

User Guide.

Incorrect memory configuration.

Corrective Actions

Check screen for specific error messages. See

"Troubleshooting System

Memory" on page 181.

E2022 General failure during POST.

General failure after video.

Check screen for specific error messages.

Check screen message.

E2025 QPI initializati on error.

Contact support.

QuickPath Interconnect

(QPI) failure.

See "Getting Help" on page 203.

E2026 Memory initializati on error.

Contact support.

Invalid memory configuration.

Ensure that the memory modules are installed in a valid configuration. See

"General Memory Module

Installation Guidelines" on page 92. See "Getting

Help" on page 203.

E2110 Multibit

Error on DIMM

##. Reseat

DIMM.

The memory module in slot

"##" has had a multi-bit error (MBE).

See "Troubleshooting

System Memory" on page 181.

E2111 SBE log disabled on

DIMM ##.

Reseat DIMM.

The system BIOS has disabled memory single-bit error (SBE) logging and will not log any more SBEs until the system is rebooted. "##" represents the memory module implicated by the

BIOS.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Troubleshooting

System Memory" on page 181.

38

About Your System

book.book Page 39 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

E2112 Memory spared The system BIOS spared the on Card x

DIMM ##.

Power cycle memory because it has determined the memory has too many errors.

AC.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Troubleshooting

System Memory" on page 181.

E2113 Mem mirror

OFF on DIMM

## & ##.

Power cycle

AC.

The system BIOS disabled memory mirroring because it has determined one half of the mirror has had too many errors. "## & ##" represents the memory module pair implicated by the BIOS.

I1910 Intrusion detected.

Check chassis cover.

System cover has been removed.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists,

see "Troubleshooting

System Memory" on page 181.

Information only.

Check the SEL for details on the events.

Remove AC power to the system for 10 seconds or clear the SEL.

I1911 LCD Log Full.

Check SEL to review all

Errors.

LCD overflow message. A maximum of ten error messages can display sequentially on the LCD.

The eleventh message instructs the user to check the SEL for details on the events.

I1912 SEL full.

Review & clear log.

The SEL is full of events and is unable to log any more.

W1100 CPU VCORE

Regulator temp exceeding range. Check fans.

The regulator temperature has reached a point outside of the allowed range.

Check the SEL for more information and then clear the SEL.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on page 203.

About Your System

39

book.book Page 40 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

W1101 CPU VCACHE

Regulator temp exceeding range. Check fans.

The regulator temperature has reached a point outside of the allowed range.

W1102 Mem Voltage

Regulator temp exceeding range. Check fans

The regulator temperature has reached a point outside of the allowed range.

W1228

W1627

RAID

Controller battery capacity <

24hr.

Power required >

PSU wattage.

Check PSU and config.

W1628 Performance degraded.

Check PSU and system configuration.

Warns predictively that the

RAID battery has less than

24 hours of charge left.

The system configuration requires more power than what the power supply can provide.

The system configuration requires more power than what the power supply can provide, but it can boot if throttled.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on page 203.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on page 203.

Allow RAID battery to charge to greater than 24 hours of sustained charge.

If problem persists, replace the RAID battery.

See "Installing the RAID

Battery" on page 147.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.

40

About Your System

book.book Page 41 Wednesday, January 20, 2010 10:20 AM

Code Text Causes Corrective Actions

W1630 Power supply redundancy degraded.

Check PSU cables.

The power supply subsystem is no longer fully redundant, but at least one more supply can fail before the system is at risk of shutting down.

Reseat the power supplies.

See "Troubleshooting

Power Supplies" on page 179.

If the problem persists,

see "Getting Help" on page 203.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary at support.dell.com/manuals.

System Messages

System messages appear on the screen to notify you of a possible problem with the system.

NOTE:

If you receive a system message not listed in the table, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

Table 1-2.

System Messages

Message Causes Corrective Actions

Alert! iDRAC6 not responding.

Rebooting.

The iDRAC6 is not responding to BIOS communication either because it is not functioning properly or has not completed initialization. The system will reboot.

Wait for the system to reboot.

About Your System

41

book.book Page 42 Wednesday, January 20, 2010 10:20 AM

Message Causes

Alert! iDRAC6 not The iDRAC6 is hung.

responding.

Power required may exceed PSU wattage.

The iDRAC6 was remotely reset while system was booting

Alert!

Continuing

After AC recovery, the iDRAC6 takes longer than normal to boot.

system boot accepts the risk that system may power down without warning.

Corrective Actions

Remove AC power to the system for 10 seconds and restart the system.

Alert! Node

Interleaving disabled! Memory configuration does not support

Node

Interleaving.

The memory configuration does not support node interleaving, or the configuration has changed

(for example, a memory module has failed) so that node interleaving cannot be supported. The system will run but without node interleaving.

Ensure that the memory modules are installed in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information,

see "General Memory

Module Installation

Guidelines" on page 92. If

the problem persists, see

"Troubleshooting System

Memory" on page 181.

42

About Your System

book.book Page 43 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Alert! Power required exceeds

PSU wattage.

Check PSU and system configuration.

Alert!

Continuing system boot accepts the risk that system may power down without warning.

Alert! Redundant memory disabled!

Memory configuration does not support redundant memory.

Alert! System fatal error during previous boot.

The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies.

Memory Mirroring was enabled in the system setup program, but the current configuration does not support redundant memory.

A memory module may be faulty.

If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High

Output power supplies to use

the components. See "Power

Supplies" on page 154.

Check the memory modules for failure. See

"Troubleshooting System

Memory" on page 181. Reset

the memory setting, if

appropriate. See "Using the

System Setup Program and

UEFI Boot Manager" on page 63.

An error caused the system to reboot.

Check other system messages for additional information for possible causes.

System is in manufacturing mode.

Reboot to take the system out of manufacturing mode.

BIOS

MANUFACTURING

MODE detected.

MANUFACTURING

MODE will be cleared before the next boot.

System reboot required for normal operation.

About Your System

43

book.book Page 44 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

BIOS Update

Attempt Failed!

Remote BIOS update attempt failed.

Retry the BIOS update. If problem persists, see

"Getting Help" on page 203.

Caution!

NVRAM_CLR jumper is installed on system board.

NVRAM_CLR jumper is installed in the clear setting.

CMOS has been cleared.

Move the NVRAM_CLR jumper to the default position (pins 3 and 5). See

Figure 6-1 for jumper

location. Restart the system and re-enter the BIOS

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on page 63.

CPU set to minimum frequency.

CPUs with different cache sizes detected.

CPUs with different core sizes detected!

System halted

The processor speed may be intentionally set lower for power conservation.

If not an intentional setting, check any other system messages for possible causes.

Mismatched processors have been installed in the system.

Ensure that all processors have the same cache size, number of cores and logical processors, and power rating.

Ensure that the processors are properly installed. See

"Processors" on page 148.

CPUs with different logical processors detected! System halted.

CPUs with different power rating detected!

System halted.

44

About Your System

book.book Page 45 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Current boot mode is set to UEFI.

Please ensure compatible bootable media is

The system failed to boot because UEFI boot mode is enabled in BIOS and the boot operating system is non-

UEFI. available. Use the system setup

Ensure that the boot mode is set correctly and that the proper bootable media is

available. See "Using the

System Setup Program and

UEFI Boot Manager" on page 63.

program to change the boot mode as needed.

Embedded NIC x and

NIC y:

OS NIC= <ENABLED

|DISABLED>,

Management

Shared NIC=

The operating system NIC interface is set in BIOS. The

Management Shared NIC interface is set in management tools.

<ENABLED

|DISABLED>

Check the system management software or the

System Setup program for

NIC settings. If a problem is indicated, see

"Troubleshooting a NIC" on page 175.

Error 8602 -

Auxiliary Device

Failure. Verify

Mouse or keyboard cable is loose or improperly connected.

that mouse and keyboard are securely attached to

Reseat the mouse or keyboard cable.

Defective mouse or keyboard. Ensure that the mouse or keyboard is operational. See

"Troubleshooting a USB

Device" on page 174.

correct connectors.

Gate A20 failure Faulty keyboard controller; faulty system board.

General failure The operating system is unable to carry out the command.

See "Getting Help" on page 203.

This message is usually followed by specific information. Note the information, and take the appropriate action to resolve the problem.

About Your System

45

book.book Page 46 Wednesday, January 20, 2010 10:20 AM

Message

Invalid configuration information - please run SETUP program.

Causes

An invalid system configuration caused a system halt.

Invalid PCIe card found in the

Internal_Storage slot!

The system halted because an invalid PCIe expansion card is installed in the dedicated storage controller slot.

Keyboard controller failure

Faulty keyboard controller; faulty system board

Corrective Actions

Run the System Setup program and review the

current settings. See "Using the System Setup Program and UEFI Boot Manager" on page 63.

Remove the PCIe expansion card and install the integrated storage controller in the dedicated slot. See

"Integrated Storage

Controller Card" on page 143.

See "Getting Help" on page 203.

Keyboard data line failure

Keyboard stuck key failure

Keyboard cable connector is improperly connected or the keyboard is defective.

Reseat the keyboard cable. If the problem persists, see

"Troubleshooting a USB

Device" on page 174.

Keyboard fuse has failed

Overcurrent detected at the keyboard connector.

Local keyboard may not work because all user accessible USB

The USB ports are disabled in the system BIOS.

ports are disabled. If operating locally, power cycle the system and enter system setup program to change settings.

See "Getting Help" on page 203.

Power down and restart the system from the power button, and then enter the

System Setup program to enable the USB port(s). See

"Entering the System Setup

Program" on page 64.

46

About Your System

book.book Page 47 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Memory Riser <x> disabled - SMI channel training

The memory riser connector is not properly seated.

failure.

Memory Riser <x> disabled - Memory

The memory riser connector or the processor socket may be exposed to dust.

The processor has bent pins.

Buffer communication error.

Reseat the memory riser(s).

See "Removing a Memory

Riser" on page 100 and

"Installing a Memory Riser" on page 101.

Ensure that the memory riser connectors and processor sockets are clean.

Verify that there are no bent pins on the processor. If the processor has bent pins, see

"Getting Help" on page 203.

Memory Riser <x> disabled -

MemBIST error.

Memory Riser <x> disabled -

MemBIST timeout.

Memory Riser <x> disabled - Rank not found.

Memory riser <x> disabled - DIMM communication error

The memory modules are not properly seated.

The memory module connector may be exposed to dust.

Replace or reseat the memory module(s). See

"Removing Memory

Modules" on page 105 and

"Installing Memory Modules" on page 102.

Unsupported memory module.

Ensure that the memory module connectors are clean and supported memory modules are installed in a valid configuration. See

"General Memory Module

Installation Guidelines" on page 92.

Memory Riser <x> disabled - DDR training failure

Memory Riser <x> disabled - Simple memory test failure.

About Your System

47

book.book Page 48 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Memory Riser <x> disabled - No

Memory detected.

The memory modules are not properly seated.

The memory module connector may be exposed to dust.

Replace or reseat the memory module(s). See

"Removing Memory

Modules" on page 105 and

"Installing Memory Modules" on page 102.

Unsupported memory module.

Verify that the memory modules are identical and not in a locked step pair.

Memory Riser <x> disabled -

Invalid DIMM.

Unsupported memory modules in the first locked step pair.

See "General Memory

Module Installation

Guidelines" on page 92.

Replace the memory

modules. See "Removing

Memory Modules" on page 105 and "Installing

Memory Modules" on page 102.

Memory Riser <x> disabled - No

DIMM detected.

An empty memory riser is installed.

DIMM unsupported:

Memory Riser <x>

DIMM<y>

Memory Riser<x>

Lockstep pair

DIMM <y & z> disabled

Please replace the DIMM or remove the lockstep pair

Unsupported memory modules on slots 3 to 8.

Install memory modules in

the riser. See "General

Memory Module Installation

Guidelines" on page 92.

Ensure that the memory modules are installed in a valid configuration. See

"General Memory Module

Installation Guidelines" on page 92.

48

About Your System

book.book Page 49 Wednesday, January 20, 2010 10:20 AM

Message Causes

DIMM mismatch:

Memory Riser <x>

Lockstep Pair

Locked step pairs do not match.

DIMM <y & z> disabled.

Please replace the lockstep pair with matching

DIMM(s).

Corrective Actions

Ensure that the memory modules match for a locked

step pair. See "General

Memory Module Installation

Guidelines" on page 92.

MemBIST timeout:

Memory riser<x>

Locstep Pair DIMM

The memory modules are not properly seated.

<x & y> disabled.

Please replace

The memory module connector may be exposed to dust.

the DIMM(s) or remove the

Faulty memory module.

lockstep pair.

Replace or reseat the memory module(s). See

"Removing Memory

Modules" on page 105 and

"Installing Memory Modules" on page 102.

Ensure that the memory module connectors are clean.

MemBIST error:

Memory riser(s)

<x> Locstep Pair

DIMM <x & y> disabled.

Please replace the DIMM(s) or remove the lockstep pair.

DDR training

Error: Memory riser <x> DIMM

<y>

Memory riser <x> lockstep pair <y

& z> disabled.

Please replace the DIMM(s) or remove the lockstep pair.

About Your System

49

book.book Page 50 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

DIMM population violation:

Memory riser <x>

DIMM <y>

Memory riser <x>

While mixing different rank memory modules, the lower rank memory modules are installed on slots 1 and 2 or on slots 5 and 6.

lockstep pair

DIMM <x & y> disabled.

Ensure that the memory modules are installed in a valid configuration. See

"General Memory Module

Installation Guidelines" on page 92.

Please populate

DIMM(s) with largest number of ranks in the lowest slot.

DDR Channel

Disabled.

Memory riser <x> lockstep pair

DIMM <y & z> disabled.

Memory riser <x> lockstep pair

DIMM <y & z> disabled.

Please ensure each lockstep pair is installed correctly.

50

About Your System

book.book Page 51 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

DellMemBIST timeout: Memory riser <x> DIMM

The memory modules are not properly seated.

<y>

Memory riser <x>

The memory module connector may be exposed to dust.

lockstep pair

DIMM <x & y>

Faulty memory module.

disabled.

Replace or reseat the memory module(s). See

"Removing Memory

Modules" on page 105 and

"Installing Memory Modules" on page 102.

Ensure that the memory module connectors are clean.

Please replace the DIMM(s) or remove the lockstep pair.

DellMemBIST error: Memory riser <x> DIMM

<y>

Memory riser <x> lockstep pair

DIMM <x & y> disabled.

Please replace the DIMM or remove the lockstep pair.

Manufacturing mode detected.

Memory address line failure at address, read value expecting value.

System is in manufacturing mode.

Reboot to take the system out of manufacturing mode.

Faulty or improperly installed memory modules.

See "Troubleshooting System

Memory" on page 181.

Memory double word logic failure at address, read value expecting value.

Faulty or improperly installed memory modules.

See "Troubleshooting System

Memory" on page 181.

About Your System

51

book.book Page 52 Wednesday, January 20, 2010 10:20 AM

Message

Memory write/read failure at address, read value expecting value.

Causes Corrective Actions

Memory

Initialization

Warning: Memory size may be reduced.

Invalid memory configuration. The system will run but with less memory than is physically available.

Ensure that the memory modules are installed in a valid configuration. See

"General Memory Module

Installation Guidelines" on page 92.

Memory odd/even logic failure at address, read value expecting value.

Faulty or improperly installed memory modules.

See "Troubleshooting System

Memory" on page 181.

Faulty or improperly installed memory modules.

See "Troubleshooting System

Memory" on page 181.

Memory set to minimum frequency.

Memory tests terminated by keystroke.

The memory frequency may be intentionally set lower for power conservation.

If not an intentional setting, check any other system messages for possible causes.

The current memory configuration may support only the minimum frequency.

Ensure that your memory configuration supports the higher frequency. See

"General Memory Module

Installation Guidelines" on page 92.

POST memory test was terminated by pressing a key.

Information only.

52

About Your System

book.book Page 53 Wednesday, January 20, 2010 10:20 AM

Message

No boot device available.

No boot sector on hard drive.

No timer tick interrupt.

PCI BIOS failed to install.

Causes

Faulty or missing optical drive subsystem, hard drive, or hard-drive subsystem, or no bootable USB key installed.

Incorrect configuration settings in System Setup program, or no operating system on hard drive.

Faulty system board.

PCIe device BIOS (Option

ROM) checksum failure detected during shadowing.

Cables to expansion card(s) loose; faulty or improperly installed expansion card(s).

Corrective Actions

Use a bootable USB key, CD, or hard drive. If the problem persists, see

"Troubleshooting an Internal

USB Key" on page 183,

"Troubleshooting a USB

Device" on page 174,

"Troubleshooting an Optical

Drive" on page 185, and

"Troubleshooting a Hard

Drive" on page 186. See

"Using the System Setup

Program and UEFI Boot

Manager" on page 63 for

information on setting the order of boot devices.

Check the hard-drive configuration settings in the

System Setup program. See

"Using the System Setup

Program and UEFI Boot

Manager" on page 63. If

necessary, install the operating system on your hard drive. See your operating system documentation.

See "Getting Help" on page 203.

Reseat the expansion card(s).

Ensure that all appropriate cables are securely connected to the expansion card(s). If the problem persists, see

"Troubleshooting Expansion

Cards" on page 189.

About Your System

53

book.book Page 54 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

PCIe Training

Error: Expected

Link Width is x,

Actual Link Width is y.

Faulty or improperly installed

PCIe card in the specified slot.

Reseat the PCIe card in the specified slot number. See

"Troubleshooting Expansion

Cards" on page 189. If the

problem persists, see

"Getting Help" on page 203.

Plug & Play

Configuration

Error.

Error encountered in initializing PCIe device; faulty system board.

Install the NVRAM_CLR jumper in the clear position

(pins 1 and 3) and reboot the

system. See Figure 6-1 for

jumper location. If the problem persists, see

"Troubleshooting Expansion

Cards" on page 189.

Read fault

Requested sector not found.

The operating system cannot read from the hard drive, optical drive, or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

Replace the optical medium,

USB medium or device.

Ensure that the SAS backplane, USB, or SATA cables are properly connected. See

"Troubleshooting a USB

Device" on page 174,

"Troubleshooting an Optical

Drive" on page 185, or

"Troubleshooting a Hard

Drive" on page 186 for the

appropriate drive(s) installed in your system.

SATA Port x device not found.

There is no device connected to the specified SATA port.

Information only.

54

About Your System

book.book Page 55 Wednesday, January 20, 2010 10:20 AM

Message

SATA port x device autosensing error

SATA port x device configuration error.

Causes

The drive connected to the specified SATA port is faulty.

Corrective Actions

Replace the faulty drive.

SATA port x device error

Sector not found

Seek error

Seek operation failed

Shutdown failure

Faulty hard drive, USB device, or USB medium.

General system error.

Replace the USB medium or device. Ensure that the USB or SAS backplane cables are properly connected. See

"Troubleshooting a USB

Device" on page 174 or

"Troubleshooting a Hard

Drive" on page 186 for the

appropriate drive(s) installed in your system.

See "Getting Help" on page 203.

The amount of system memory has changed.

Time-of-day clock stopped.

Memory has been added or removed or a memory module may be faulty.

If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See

"Troubleshooting System

Memory" on page 181.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 178.

About Your System

55

book.book Page 56 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Time-of-day not set - please run

SETUP program.

Incorrect Time or Date settings; faulty system battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on page 63. If the problem

persists, replace the system

battery. See "System Battery" on page 157.

Timer chip counter 2 failed.

Faulty system board.

See "Getting Help" on page 203.

Information only.

TPM or TCM configuration operation honored. System will now reset.

A Trusted Platform Module

(TPM) or China Trusted

Computing Model (TCM) configuration command has been entered. The system will reboot and execute the command.

TPM or TCM configuration operation is pending. Press

(I) to Ignore OR

(M) to Modify to allow this change and reset the system.

This message displays during system restart after a TPM or

TCM configuration command has been entered.

User interaction is required to proceed.

Enter I or M to proceed.

WARNING:

Modifying could prevent security.

TPM or TCM failure.

A TPM or TCM function has failed.

See "Getting Help" on page 203.

56

About Your System

book.book Page 57 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Unable to launch

System Services image. System halted!

System halted after F10 keystroke because System

Services image is either corrupted in the system firmware or has been lost due to system board replacement.

Restart the system and update the Lifecycle

Controller repository to the latest software to restore full functionality. See the

Lifecycle Controller user documentation for more information.

The iDRAC6 Enterprise card flash memory may be corrupted.

Restore the flash memory using the latest version on support.dell.com. See the iDRAC6 user's guide for instructions on performing a field replacement of the flash memory.

Unexpected interrupt in protected mode.

Unsupported CPU combination.

Improperly seated memory modules or faulty keyboard/mouse controller chip.

Reseat the memory modules.

See "Troubleshooting System

Memory" on page 181. If the

problem persists, see

"Getting Help" on page 203.

Processor(s) is not supported by the system.

Install a supported processor or processor combination.

See "Processors" on page 148.

Unsupported CPU stepping detected.

Warning: A fatal error has caused system reset!

Please check the

A fatal system error occurred and caused the system to reboot. system event log!

Check the SEL for information that was logged during the error. See the applicable troubleshooting

section in "Troubleshooting

Your System" on page 173 for

any faulty components specified in the SEL.

About Your System

57

book.book Page 58 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

Warning: Control

Panel is not installed.

The control panel is not installed or has a faulty cable connection.

Install the control panel, or check the cable connections between the display module, the control panel board, and the system board. See

"Control Panel Assembly" on page 163.

Warning! No micro Micro code update failed.

code update loaded for processor n.

Update the BIOS firmware.

See "Getting Help" on page 203.

Warning! Power required exceeds

PSU wattage.

Check PSU and system configuration.

The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies.

Warning!

Performance degraded. CPU and memory set to minimum frequencies to meet PSU wattage.

System will reboot.

If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High

Output power supplies to use

the components. See "Power

Supplies" on page 154.

Warning! PSU mismatch. PSU redundancy lost.

Check PSU.

A High Output power supply and an Energy Smart power supply are installed in the system at the same time.

Install two High Output or two Energy Smart power supplies in the system.

You can also run the system on one power supply until you can obtain two power supplies of the same type.

See "Troubleshooting Power

Supplies" on page 179.

58

About Your System

book.book Page 59 Wednesday, January 20, 2010 10:20 AM

Message Causes Corrective Actions

The memory configuration is not optimal. The recommended memory configuration is: <message>

Write fault

Write fault on selected drive.

Invalid memory configuration. The system will run but with reduced functionality.

Ensure that the memory modules are installed in a valid configuration. See

"General Memory Module

Installation Guidelines" on page 92. If the problem

persists, see

"Troubleshooting System

Memory" on page 181.

Faulty USB device, USB medium, optical drive assembly, hard drive, or harddrive subsystem.

Replace the USB medium or device. Ensure that the USB,

SAS backplane, or SATA cables are properly connected. See

"Troubleshooting a USB

Device" on page 174,

"Troubleshooting an Internal

USB Key" on page 183, and

"Troubleshooting a Hard

Drive" on page 186.

Warning: QPI links operating in Slow Speed

Mode.

Warning: QPI link between <Agent X>

Port <Y> and

<Agent X1> <Port

Y1> failed.

The processor has bent pins.

The processor is not properly seated on the processor socket.

Verify that there are no bent pins on the processor. If the processor has bent pins, see

"Getting Help" on page 203.

Reseat the processors. See

"Removing a Processor" on page 148 and "Installing a

Processor" on page 152.

If the problem persists, see

"Getting Help" on page 203.

Warning: QPI link between <Agent X>

Port <Y> and

<Agent X1> <Port

Y1> degraded to half-width.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary at support.dell.com/manuals.

About Your System

59

book.book Page 60 Wednesday, January 20, 2010 10:20 AM

Warning Messages

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette.

Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).

NOTE:

Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application.

Diagnostics Messages

The system diagnostic utilities may issue messages if you run diagnostic tests

on your system. See "Running the System Diagnostics" on page 193 for more

information about system diagnostics.

Alert Messages

Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.

Other Information You May Need

WARNING:

See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document.

• The rack documentation included with your rack solution describes how to install your system into a rack.

• The Getting Started Guide provides an overview of system features, setting up your system, and technical specifications.

60

About Your System

book.book Page 61 Wednesday, January 20, 2010 10:20 AM

• Dell systems management application documentation at support.dell.com/manuals provides information about installing and using the systems management software.

• Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.

NOTE:

Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents.

About Your System

61

book.book Page 62 Wednesday, January 20, 2010 10:20 AM

62

About Your System

book.book Page 63 Wednesday, January 20, 2010 10:20 AM

Using the System Setup Program and UEFI Boot Manager

The System Setup program is the BIOS program that enables you to manage your system hardware and specify BIOS-level options. From the System Setup program, you can:

• Change the NVRAM settings after you add or remove hardware

• View the system hardware configuration

• Enable or disable integrated devices

• Set performance and power management thresholds

• Manage system security

Choosing the System Boot Mode

The System Setup program also enables you to specify the boot mode for installing your operating system:

• BIOS boot mode (the default) is the standard BIOS-level boot interface.

• UEFI boot mode is an enhanced 64-bit boot interface based on Unified

Extensible Firmware Interface (UEFI) specifications that overlays the

system BIOS. See "Entering the UEFI Boot Manager" on page 76 for more

information on this interface.

You must select the boot mode in the Boot Mode field of the "Boot Settings

Screen" on page 69 screen of the System Setup program. Once you specify the

boot mode, the system boots in the specified boot mode and you proceed then to install your operating system from that mode. Thereafter, you must boot the system to the same boot mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating system from the other boot mode will cause the system to halt immediately at startup.

NOTE:

Operating systems must be UEFI-compatible (for example, Microsoft

®

Windows Server

®

2008 x64 version) to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the

BIOS boot mode.

Using the System Setup Program and UEFI Boot Manager

63

book.book Page 64 Wednesday, January 20, 2010 10:20 AM

Entering the System Setup Program

1 Turn on or restart your system.

2 Press <F2> immediately after you see the following message:

<F2> = System Setup

If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart your system and try again.

Responding to Error Messages

If an error message appears while the system is booting, make a note of the

message. See "System Messages" on page 41 for an explanation of the message

and suggestions for correcting errors.

NOTE:

After installing a memory upgrade, it is normal for your system to display a message the first time you start your system.

Using the System Setup Program Navigation Keys

Keys

Up arrow or <Shift><Tab>

Down arrow or <Tab>

Spacebar, <+>, < – >, left and right arrows

<Esc>

<F1>

Action

Moves to the previous field.

Moves to the next field.

Cycles through the settings in a field. In many fields, you can also type the appropriate value.

Exits the System Setup program and restarts the system if any changes were made.

Displays the System Setup program ' s help file.

NOTE:

For most of the options, any changes that you make are recorded but do not take effect until you restart the system.

64

Using the System Setup Program and UEFI Boot Manager

book.book Page 65 Wednesday, January 20, 2010 10:20 AM

System Setup Options

Main Screen

NOTE:

The options for the System Setup program change based on the system configuration.

NOTE:

The System Setup program defaults are listed under their respective options in the following sections, where applicable.

Option

System Time

System Date

Memory Settings

Processor Settings

Description

Sets the time on the system's internal clock.

Sets the date on the system's internal calendar.

Displays information related to installed memory. See

"Memory Settings Screen" on page 67.

Displays information related to processors (speed,

cache size, and so on). See "Processor Settings Screen" on page 68.

Using the System Setup Program and UEFI Boot Manager

65

book.book Page 66 Wednesday, January 20, 2010 10:20 AM

Option

SATA Settings

Boot Settings

Integrated Devices

PCI IRQ Assignment

Serial Communication

Embedded Server

Management

Power Management

System Security

Keyboard NumLock

( On default)

Description

Displays a screen to enable or disable the integrated

SATA controller and ports. See "SATA Settings Screen" on page 69.

Displays a screen to specify the boot mode (BIOS or

UEFI). For BIOS boot mode, you can also specify the

boot devices. See "Boot Settings Screen" on page 69.

Displays a screen to enable or disable integrated device controllers and ports, and to specify related features

and options. See "Integrated Devices Screen" on page 70.

Displays a screen to change the IRQ assigned to each of the integrated devices on the PCI bus, and any installed

expansion card that requires an IRQ. See "PCI IRQ

Assignments Screen" on page 71.

Displays a screen to enable or disable the serial ports

and specify related features and options. See "Serial

Communication Screen" on page 72.

Displays a screen to configure the front-panel LCD options and to set a user-defined LCD string. See

"Embedded Server Management Screen" on page 73.

Enables you to manage power usage of the processor(s), fans, and memory modules with preconfigured or

customized settings. See "Power Management Screen" on page 73.

Displays a screen to configure the system password and

setup password features. See "System Security Screen"

on page 74, "Using the System Password" on page 79,

and "Using the Setup Password" on page 81 for more

information.

Determines whether your system starts up with the

NumLock mode activated on 101- or 102-key keyboards

(does not apply to 84-key keyboards).

66

Using the System Setup Program and UEFI Boot Manager

book.book Page 67 Wednesday, January 20, 2010 10:20 AM

Option

Report Keyboard Errors

( Report default)

F1/F2 Prompt on Error

(Enabled default)

Description

Enables or disables reporting of keyboard errors during the POST. Select Report for host systems that have keyboards attached. Select Do Not Report to suppress all error messages relating to the keyboard or keyboard controller during POST. This setting does not affect the operation of the keyboard itself if a keyboard is attached to the system.

Enables the system to halt on errors during POST, which allows the user to observe events that may scroll by unnoticed during normal POST. The user can press

<F1> to continue or <F2> to enter the System Setup program.

CAUTION:

When setting this option to Disabled, the system will not halt if an error occurs during

POST. Any critical errors will be displayed and logged in the system event log.

Memory Settings Screen

Option

System Memory Size

System Memory Type

System Memory Speed

Video Memory

System Memory Testing

(Enabled default)

Redundant Memory

(Disabled default)

Node Interleaving

(Disabled default)

Description

Displays the amount of system memory.

Displays the type of system memory.

Displays the system memory speed.

Displays the amount of video memory.

Specifies whether system memory tests are run at system boot. Options are Enabled and Disabled.

Specifies whether redundant memory is enabled on the system. Options are Mirror Mode, Spare Mode, and

Disabled.

If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If

Disabled, the system supports Non-Uniform Memory architecture (NUMA) (asymmetric) memory configurations.

Using the System Setup Program and UEFI Boot Manager

67

book.book Page 68 Wednesday, January 20, 2010 10:20 AM

Processor Settings Screen

Option

64-bit

Core Speed

Bus Speed

Logical Processor

(Enabled default)

Virtualization Technology

(Disabled default)

Adjacent Cache Line

Prefetch

(Enabled default)

Hardware Prefetcher

(Enabled default)

Execute Disable

(Enabled default)

Number of Cores per

Processor

(All default)

Turbo Mode

Description

Specifies if the processor(s) support 64-bit extensions.

Displays the processor clock speed.

Displays the processor bus speed.

On processors that support Simultaneous Multi-

Threading (SMT) technology, each processor core supports up to two logical processors. If this field is set to

Enabled, the BIOS reports both logical processors. If set to Disabled, only one logical processor is monitored by the BIOS.

Enabled permits virtualization software to use the virtualization technology incorporated in the processor.

NOTE:

Disable this feature if your system will not be running virtualization software.

Enable or disables system optimization for sequential memory access.

Enables or disables the hardware prefetcher.

Enables or disables Execute Disable Memory Protection

Technology.

If set to All, the maximum number of cores in each processor is enabled.

C1E

(Enabled default)

C States

Processor Family-Model-

Stepping

If Turbo Boost Technology is supported by the processor(s), enables or disables Turbo Mode.

When set to Enabled, the processor can switch to a minimum performance state when idle.

When set to Enabled, the processor(s) can operate in all available power states.

Displays the family, model, and stepping of the selected processor.

68

Using the System Setup Program and UEFI Boot Manager

book.book Page 69 Wednesday, January 20, 2010 10:20 AM

SATA Settings Screen

Option

Embedded SATA

(Off default)

Port A

(Off default)

Description

ATA Mode enables the integrated SATA controller. Off disables the controller.

Auto enables BIOS support for the device attached to

SATA port A. Off disables BIOS support for the device.

Boot Settings Screen

Option

Boot Mode

(BIOS default)

Boot Sequence

Hard-Disk Drive

Sequence

Description

CAUTION:

Switching the boot mode could prevent the system from booting if the operating system was not installed in the same boot mode.

If the system operating system supports Unified

Extensible Firmware Interface, you can set this option to

UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems.

NOTE:

Setting this field to UEFI disables the Boot

Sequence, Hard-Disk Drive Sequence, and USB Flash Drive

Emulation Type fields.

If Boot Mode is set to BIOS, this field tells the system where the operating system files needed for startup are located. If Boot Mode is set to UEFI, you can access the

UEFI boot manager utility by rebooting the system and pressing <F11> when prompted to do so.

Determines the order in which the BIOS attempts to boot from hard drives in the system during system startup.

Using the System Setup Program and UEFI Boot Manager

69

book.book Page 70 Wednesday, January 20, 2010 10:20 AM

Option

USB Flash Drive

Emulation Type

(Auto default)

Boot Sequence Retry

(Disabled default)

Description

Determines the emulation type for a USB flash drive.

Hard disk allows the USB flash drive to act as a hard drive. Floppy allows the USB flash drive to act as a removable diskette drive. Auto automatically chooses an emulation type.

Auto automatically chooses the appropriate emulation type for the device, except for devices installed in the internal SD card slot. A device installed in the internal

SD card slot will automatically emulate a hard drive. If you install a device in this slot that is configured as a removable diskette drive, you must manually set the emulation type to Floppy.

If this field is enabled and the system has failed to boot, the system will reattempt to boot after 30 seconds.

Integrated Devices Screen

70

Option Description

Integrated SAS Controller

(Enabled default)

Enables or disables the integrated SAS controller.

User Accessible USB Ports

(All Ports On default)

Enables or disables the user accessible USB ports.

Options are All Ports On, Only Back Ports On, and All

Ports Off.

Enables or disables the internal USB port.

Internal USB Port

(On default)

Internal SD Card Port

Redundancy

(Disabled default)

Embedded NIC1 and

NIC2

(Enabled default)

Embedded NIC3 and

NIC4

(Enabled default)

Enables or disables the internal SD card port.

Enables or disables the internal dual SD module mirror mode.

Enables or disables the operating system interface of the embedded NICs. The NICs can also be accessed through the system's management controller.

Enables or disables the operating system interface of the embedded NICs. The NICs can also be accessed through the system's management controller.

Using the System Setup Program and UEFI Boot Manager

book.book Page 71 Wednesday, January 20, 2010 10:20 AM

Option

Embedded Gb NIC x

(NIC1 default: Enabled with PXE;

Other NICs: Enabled)

MAC Address

Capability Detected

OS Watchdog Timer

(Disabled default)

I/OAT DMA Engine

(Disabled default)

Embedded Video

Controller

(Enabled default)

SR-IOV Global Enable

(Enabled default)

Description

Enables or disables the integrated NIC. Options are

Enabled, Enabled with PXE, Enabled with iSCSI Boot, and Disabled. PXE support allows the system to boot from the network.

Displays the MAC address for the integrated 10/100/1000

NIC.

Displays the NIC features of the LOM NIC hardware key.

NOTE:

Some LOM features may require the installation of an additional driver.

Sets a timer to monitor the operating system for activity, and aids in recovery if the system stops responding.

When Enabled, the operating system is allowed to initialize the timer. When Disabled, the timer is not initialized.

NOTE:

This feature is usable only with operating systems that support WDAT implementations of the Advanced

Configuration and Power Interface (ACPI) 3.0b specification.

Enables or disables the I/O Acceleration Technology feature.

Enables or disables BIOS support for the integrated video controller.

NOTE:

This field can be disabled only if an add-in video card is present. If this field is disabled, remote access features such as virtual KVM are not available.

Enables or disables the BIOS configuration of Single

Root I/O Virtualization (SR-IOV) devices.

PCI IRQ Assignments Screen

Option

< PCIe device>

Description

Use the <+> and <-> keys to manually select an IRQ for a given device, or select Default to allow the BIOS to select an IRQ value at system startup.

Using the System Setup Program and UEFI Boot Manager

71

book.book Page 72 Wednesday, January 20, 2010 10:20 AM

Serial Communication Screen

Option Description

Serial Communication

(On without Console

Redirection default)

Serial Port Address

(Serial Device 1=COM1,

Serial Device2=COM2 default)

Selects whether the serial communication devices

(Serial Device 1 and Serial Device 2) are enabled in

BIOS. BIOS console redirection can also be enabled and the port address used can be specified.

Options are On without Console Redirection, On with

Console Redirection via COM1, On with Console

Redirection via COM2, and Off.

Sets the serial port addresses for the two serial devices.

NOTE:

Only Serial Device 2 can be used for Serial Over

LAN (SOL). To use console redirection by SOL, configure the same port address for console redirection and the serial device.

External Serial Connector Specifies whether Serial Device 1, Serial Device 2, or

Remote Access Device has access to the external serial connector.

NOTE:

Only Serial Device 2 can be used for Serial Over

LAN (SOL). To use console redirection by SOL, configure the same port address for console redirection and the serial device.

Failsafe Baud Rate

(115200 default)

Remote Terminal Type

(VT 100/VT220 default)

Redirection After Boot

(Enabled default)

Displays the failsafe baud rate used for console redirection. BIOS attempts to determine the baud rate automatically. This failsafe baud rate is used only if the attempt fails. This rate should not be adjusted.

Sets the remote console terminal type, either

VT100/VT220 or ANSI.

Enables or disables BIOS console redirection when the operating system is loaded.

72

Using the System Setup Program and UEFI Boot Manager

book.book Page 73 Wednesday, January 20, 2010 10:20 AM

Embedded Server Management Screen

Option

Front Panel LCD

Options

User-Defined LCD

String

Description

Options are User Defined String, Model Number, or

None.

If the LCD Home screen is set to an option other than these three choices, the option will be displayed as

"Advanced" in the BIOS. In this event, the option cannot be changed in the BIOS unless it is changed back to User

Defined String, Model Number, or None through another LCD configuration utility (such as the iDRAC

Configuration Utility or the LCD panel menu).

You can enter a name or other identifier for the system, to be displayed on the LCD module screen.

Power Management Screen

Option

Power Management

Description

Options are OS Control, Active Power Controller,

Custom, or Maximum Performance. For all but the

Custom setting, the BIOS pre-configures the power settings on this screen as follows:

• OS Control sets the CPU power to OS DBPM, the fan power to Minimum Power, and the memory power to

Maximum Performance. In this setting, all processor performance information is passed from the system

BIOS to the operating system for control. The operating system sets the processor performance based on processor utilization.

• Active Power Controller sets the CPU power to System

DBPM, the fan power to Minimum Power, and the memory power to Maximum Performance. The BIOS sets the processor performance based on processor utilization.

• Maximum Performance sets all fields to Maximum

Performance.

If you select Custom, you can configure each option independently.

Using the System Setup Program and UEFI Boot Manager

73

book.book Page 74 Wednesday, January 20, 2010 10:20 AM

Option

CPU Power and

Performance

Management

Fan Power and

Performance

Management

Memory Power and

Performance

Management

System Security Screen

Description

Options are OS DBPM, System DBPM, Maximum

Performance, or Minimum Power.

Options are Maximum Performance or Minimum Power.

Options are Maximum Performance, a specified frequency, or Minimum Power.

Option

System Password

Setup Password

Password Status

(Unlocked default)

Description

Displays the current status of the password security feature and allows a new system password assignment and verification.

NOTE:

See Using the "Using the System Password" on page 79 for more information.

Restricts access to the System Setup program by using a setup password.

NOTE:

See "Using the System Password" on page 79 for

more information.

When Setup Password is assigned and this field is

Locked, the system password cannot be changed or disabled at system start-up.

See "Using the System Password" on page 79 for more

information.

74

Using the System Setup Program and UEFI Boot Manager

book.book Page 75 Wednesday, January 20, 2010 10:20 AM

Option

TPM Security

(Off default)

TPM Activation

(No Change default)

TPM Clear

(No default)

Power Button

(Enabled default)

Description

Sets the reporting of the Trusted Platform Module

(TPM) in the system.

If Off, the presence of the TPM is not reported to the operating system.

If On with Pre-boot Measurements, the system reports the TPM to the operating system and stores the pre-boot measurements to the TPM during POST.

If On without Pre-boot Measurements, the system reports the TPM to the operating system and bypasses pre-boot measurements.

When set to Activate, the TPM is enabled to default settings. When set to Deactivate, the TPM is disabled.

The No Change state initiates no action. The operational state of the TPM remains unchanged (all user settings for the TPM are preserved).

NOTE:

This field is read-only when TPM Security is set to

Off.

CAUTION:

Clearing the TPM will lose all encryption keys in the TPM. This option prevents booting to the operating system and results in data loss if the encryption keys cannot be restored. Back up the TPM keys prior to enabling this option.

When set to Yes, all TPM contents are cleared.

NOTE:

This field is read-only when TPM Security is set to

Off.

If Enabled, the power button can turn the system's power off and on. On an ACPI-compliant operating system, the system performs an orderly shutdown before power is turned off.

When Disabled, the button can only turn on system power.

Using the System Setup Program and UEFI Boot Manager

75

book.book Page 76 Wednesday, January 20, 2010 10:20 AM

76

Option

NMI Button

(Disabled default)

Description

CAUTION:

Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing this button halts the operating system and displays a diagnostic screen.

Enables or disables the NMI feature.

AC Power Recovery

(Last default)

Determines how the system reacts when power is restored. If set to Last, the system returns to the last power state. On turns on the system after power is restored. Off allows the system to remain off after power is restored.

AC Power Recovery Delay Determines when the system restarts after power is restored. Options are Immediate, Random (a random value of 30 to 240 seconds), or a user-defined value of 30 to 240 seconds.

Exit Screen

Press <Esc> to exit the System Setup program; the Exit screen displays:

• Save Changes and Exit

• Discard Changes and Exit

• Return to Setup

Entering the UEFI Boot Manager

NOTE:

Operating systems must be 64-bit UEFI-compatible (for example, Microsoft

Windows Server

®

2008 x64 version) to be installed from the UEFI boot mode. DOS

® and 32-bit operating systems can only be installed from the BIOS boot mode.

NOTE:

The Boot Mode must be set to UEFI in the System Setup program to access the UEFI Boot Manager.

The UEFI Boot Manager enables you to:

• Add, delete, and arrange boot options

• Access the System Setup program and BIOS-level boot options without rebooting

1 Turn on or restart your system.

Using the System Setup Program and UEFI Boot Manager

book.book Page 77 Wednesday, January 20, 2010 10:20 AM

2 Press <F11> after you see the following message:

<F11> = UEFI Boot Manager

NOTE:

The system will not respond until the USB keyboard is active.

If your operating system begins to load before you press <F11>, allow the system to finish booting, and then restart your system and try again.

Using the UEFI Boot Manager Navigation Keys

Keys

Up arrow

Down arrow

Spacebar, <Enter>, <+>,

< – >

<Esc>

Action

Moves to and highlights the previous field.

Moves to and highlights the next field.

Cycles through the settings in a field.

<F1>

UEFI Boot Manager Screen

Refreshes the UEFI Boot Manager screen, or returns to the UEFI Boot Manager screen from the other program screens.

Displays the UEFI Boot Manager help file.

Option

Continue

< Boot options>

UEFI Boot Settings

Description

The system attempts to boot to devices starting with the first item in the boot order. If the boot attempt fails, the system will continue with the next item in the boot order until the boot is successful or no more boot options are found.

Displays the list of available boot options (marked with asterisks). Select the boot option you wish to use and press Enter.

NOTE:

If you hot-add a boot device, press <Esc> to refresh the list of boot options.

Enables you to add, delete, enable, or disable boot options; change boot order; or execute a one-time boot option.

Using the System Setup Program and UEFI Boot Manager

77

book.book Page 78 Wednesday, January 20, 2010 10:20 AM

Option

System Utilities

Description

Enables you to access the System Setup program,

System Services (Unified Server Configurator [USC]),

Diagnostics, and BIOS-level boot options.

UEFI Boot Settings Screen

Option Description

Add Boot Option

Delete Boot Option

Enable/Disable Boot

Option

Change Boot Order

Adds a new boot option.

Deletes an existing boot option.

Disables and enables a boot option in the boot option list.

Changes the order of the boot option list.

One-Time Boot From File Sets a one-time boot option not included in the boot option list.

System Utilities Screen

Option

System Setup

System Services

BIOS Boot Manager

Reboot System

Description

Accesses the System Setup program without rebooting.

Restarts the system and access the Lifecycle Controller, which allows you to run utilities such as system diagnostics.

Accesses the BIOS-level boot options list without rebooting. This option enables you to conveniently switch to BIOS boot mode if you need to boot to a device with a non-UEFI operating system, such as a bootable DOS media with diagnostics software.

Restarts the system.

78

Using the System Setup Program and UEFI Boot Manager

book.book Page 79 Wednesday, January 20, 2010 10:20 AM

System and Setup Password Features

NOTE:

For a forgotten password, see "Disabling a Forgotten Password" on page 201.

Your system is shipped without the system password feature enabled. Operate the system only with system password protection.

CAUTION:

The password features provide a basic level of security for the data on your system.

CAUTION:

Anyone can access the data stored on your system if the system is running and unattended.

Using the System Password

When a system password is assigned, the system prompts for the system password after the system starts and only those with the password have full use of the system.

Assigning a System Password

Before assigning a system password, enter the System Setup program and check the System Password option.

When a system password is assigned, System Password is Enabled. If

Password Status is Unlocked, you can change the system password. If Locked, you cannot change the system password. Disabling the password jumper on the system board sets System Password to Disabled, and you cannot change or enter a new system password.

When a system password is not assigned and the password jumper on the system board is in the enabled position, System Password is Not Enabled and

Password Status is Unlocked. To assign a system password:

1 Verify that Password Status is Unlocked.

2 Highlight the System Password option and press <Enter>.

3 Type your new system password.

You can use up to 32 characters in your password.

As you type, placeholders appear in the field.

Using the System Setup Program and UEFI Boot Manager

79

book.book Page 80 Wednesday, January 20, 2010 10:20 AM

80

The password assignment is not case-sensitive. Certain key combinations are invalid and if you enter one, the system beeps. To erase a character, press <Backspace> or the left-arrow key.

NOTE:

To escape from the field without assigning a system password, press

<Enter> to move to another field, or press <Esc> prior to completing step 5.

4 Press <Enter>.

5 To confirm your password, type it a second time and press <Enter>.

System Password changes to Enabled. Exit the System Setup program and begin using your system.

6 Either reboot the system now for the password protection to take effect or continue working.

NOTE:

Password protection does not take effect until the system reboots.

Using Your System Password to Secure Your System

NOTE:

If you have assigned a setup password (see "Using the Setup Password" on page 81), the system accepts your setup password as an alternate system

password.

When Password Status is Unlocked, you have the option to leave the password security enabled or to disable password security.

To leave the password security enabled:

1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>.

2 Type your password and press <Enter>.

To disable the password security:

1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>.

2 Type your password and press <Ctrl><Enter>.

When Password Status is Locked, you must type the password and press

<Enter> when prompted at reboot.

If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an error message that the system has halted and will shut down.

Even after you shut down and restart the system, the error message continues to be displayed until the correct password is entered.

Using the System Setup Program and UEFI Boot Manager

book.book Page 81 Wednesday, January 20, 2010 10:20 AM

NOTE:

You can use the Password Status option in conjunction with the System

Password and Setup Password options to protect your system from unauthorized changes.

Deleting or Changing an Existing System Password

1 Enter the System Setup program and select the System Security.

2 Highlight Setup Password, press <Enter> to access the setup password window. Press <Enter> twice to clear the existing setup password.

The setting changes to Not Enabled.

3 If you want to assign a new setup password, perform the steps in "Assigning a Setup Password" on page 81.

Using the Setup Password

Assigning a Setup Password

You can assign a setup password only when the Setup Password is Not

Enabled. To assign a setup password, highlight the Setup Password option and press the <+> or <–> key. The system prompts you to enter and verify the password.

NOTE:

The setup password can be the same as the system password. If the two passwords are different, the setup password can be used as an alternate system password. The system password cannot be used in place of the setup password.

You can use up to 32 characters in your password.

As you type, placeholders appear in the field.

The password assignment is not case-sensitive. Certain key combinations are invalid and if you enter one, the system beeps. To erase a character, press

<Backspace> or the left-arrow key.

When you verify the password, the Setup Password changes to Enabled. The next time you enter the System Setup program, the system prompts you for the setup password.

A change to the Setup Password option becomes effective immediately

(restarting the system is not required).

Using the System Setup Program and UEFI Boot Manager

81

book.book Page 82 Wednesday, January 20, 2010 10:20 AM

Operating With a Setup Password Enabled

If Setup Password is Enabled, you must enter the correct setup password before modifying most of the System Setup options.

If you do not enter the correct password in three attempts, the system lets you view, but not modify, the System Setup screens. The following options are exceptions: If System Password is not Enabled and is not locked through the

Password Status option, you can assign a system password. You cannot disable or change an existing system password.

NOTE:

You can use the Password Status option in conjunction with the Setup

Password option to protect the system password from unauthorized changes.

Deleting or Changing an Existing Setup Password

1 Enter the System Setup program and select the System Security.

2 Highlight Setup Password, press <Enter> to access the setup password window. Press <Enter> twice to clear the existing setup password.

The setting changes to Not Enabled.

3 If you want to assign a new setup password, perform the steps in "Assigning a Setup Password" on page 81."

Embedded System Management

The Lifecycle Controller is an embedded utility that enables systems management tasks from an embedded environment throughout the server’s lifecycle.

Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.

NOTE:

Certain platform configurations may not support the full set of features provided by the Lifecycle Controller.

For more information about setting up the Lifecycle Controller, configuring hardware and firmware, and deploying the operating system, see the Lifecycle

Controller documentation on the Dell Support website at support.dell.com/manuals.

82

Using the System Setup Program and UEFI Boot Manager

book.book Page 83 Wednesday, January 20, 2010 10:20 AM

iDRAC Configuration Utility

The iDRAC Configuration Utility is a pre-boot configuration environment that allows you to view and set parameters for the iDRAC6 and for the managed server.

The iDRAC Configuration Utility provides the following features:

• Enables fault logging and SNMP alerting

• Provides access to system event log and sensor status

• Allows control of system functions including power on and off

• Functions independently of the system’s power state or the system’s operating system

• Provides text console redirection for system setup, text-based utilities, and operating system consoles

In addition, the iDRAC Configuration Utility enables you to:

• Configure, enable, or disable the iDRAC6 local area network through the dedicated iDRAC6 Enterprise card port or the embedded NIC1.

• Enable or disable IPMI over LAN

• Enable a LAN Platform Event Trap (PET) destination

• Attach or detach the Virtual Media devices

• Change the administrative user name and password and manage user privileges

• View System Event Log (SEL) messages or clear messages from the log

For additional information on using iDRAC6, see the documentation for iDRAC6 and systems management applications.

Entering the iDRAC Configuration Utility

1 Turn on or restart your system.

2 Press <Ctrl><E> when prompted during POST.

If your operating system begins to load before you press <Ctrl><E>, allow the system to finish booting, and then restart your system and try again.

Using the System Setup Program and UEFI Boot Manager

83

book.book Page 84 Wednesday, January 20, 2010 10:20 AM

84

Using the System Setup Program and UEFI Boot Manager

book.book Page 85 Wednesday, January 20, 2010 10:20 AM

Installing System Components

Recommended Tools

You may need the following items to perform the procedures in this section:

• Key to the system keylock

• #1 and #2 Phillips screwdrivers

• T8 and T10 Torx drivers

• Wrist grounding strap

Inside the System

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Installing System Components

85

book.book Page 86 Wednesday, January 20, 2010 10:20 AM

Figure 3-1.

Inside the System

4

5

3

1

2

6

7

9

11 10

1 optical drive (optional)

3 memory risers (up to 8)

5 power supply bays (4)

7 I/O card

9 cooling fan assembly

11 system identification panel

2 control panel display

4 cooling fans (up to 6)

6 PCIe expansion card

8 integrated storage controller card

10 hard drives (up to 16)

8

86

Installing System Components

book.book Page 87 Wednesday, January 20, 2010 10:20 AM

Front Bezel (Optional)

Removing the Front Bezel

1 Unlock the keylock at the left end of the bezel.

2 Lift up the release latch next to the keylock.

3 Rotate the left end of the bezel away from the front panel.

4 Unhook the right end of the bezel and pull the bezel away from the system.

Figure 3-2.

Removing and Installing the Front Bezel

1

2

3

1 release latch

3 front bezel

2 key lock

Installing the Front Bezel

1 Hook the right end of the bezel onto the chassis.

2 Fit the free end of the bezel onto the system and secure the bezel with the

keylock. See Figure 3-2.

Installing System Components

87

book.book Page 88 Wednesday, January 20, 2010 10:20 AM

System Identification Panel

Removing the System Identification Panel

1 If applicable, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 Pull the system identification panel out of its slot in the chassis, until it is

in the lock position. See Figure 3-3. The system identification panel is

located above the hard drive slot 8.

3 To release the left portion of the system identification panel, pull the panel to the right until it disengages from the slot in the chassis.

4 To release the right portion of the system identification panel, pull the panel to the left until it disengages from the slot in the chassis.

Figure 3-3.

Removing and Installing the System Identification Panel

1

1 system identification panel

88

Installing System Components

book.book Page 89 Wednesday, January 20, 2010 10:20 AM

Installing the System Identification Panel

1 Align the system identification panel with the slot on the chassis.

2 Slide the system identification panel into the chassis, until it locks into

place. See Figure 3-3.

3 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

Opening and Closing the System

WARNING:

Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by yourself.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Opening the System

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals.

2 Rotate the latch release lock counter clockwise to the unlocked position.

See Figure 3-4.

3 Lift up the latch and slide the cover back toward the back of the system.

4 Grasp the cover on both sides and lift the cover away from the system. See

Figure 3-4.

Installing System Components

89

book.book Page 90 Wednesday, January 20, 2010 10:20 AM

Figure 3-4.

Opening and Closing the System

1 2

3

1 latch

3 cover

2 latch release lock

Closing the System

1 Place the cover onto the chassis and offset it slightly toward the back of the system, so that the chassis hooks on the back edge of the cover fit over the

corresponding slots on the back edge of the chassis. See Figure 3-4.

2 Slide the cover toward the front of the chassis till it snaps in position.

3 Push down the latch to lever the cover into the closed position.

4 Rotate the latch release lock in a clockwise direction to secure the cover.

90

Installing System Components

book.book Page 91 Wednesday, January 20, 2010 10:20 AM

System Memory

Your system supports DDR3 registered DIMMs (RDIMMs). Single-, dual-, and quad-rank DIMMs can be 1067 MHz or 1333 MHz.

The system contains eight memory risers split into four sets of two risers per

processor. Figure 3-5 shows the order of the memory risers in the system. Each

memory riser has eight DIMM sockets arranged into four channels. The first socket of each channel is marked with white release levers.

The maximum memory that is supported on your system varies according to the sizes of memory modules being used. Single-rank, dual-rank, and quadrank RDIMMs of sizes 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB are supported for a total of up to 1 TB.

NOTE:

Depending on the amount of memory installed, the system may take up to 3 minutes to display video on the screen.

Figure 3-5.

Memory Risers

Installing System Components

91

book.book Page 92 Wednesday, January 20, 2010 10:20 AM

General Memory Module Installation Guidelines

To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory.

NOTE:

Memory configurations that fail to observe these guidelines can prevent your system from starting and producing any video output.

• All populated memory risers must have identical configurations.

• The memory configuration for each processor must be identical for optimal performance.

• Memory modules of different sizes can be mixed (for example, 2 GB and

4 GB), but all populated channels must have identical configurations. The mixed memory configurations must be of the size N+/-1.

• The memory speed depends on the processor bin.

• If quad-rank memory modules are mixed with single- or dual-rank modules, the quad-rank modules must be installed in the sockets with the white release levers.

• If memory modules with different speeds are installed, they operate at the speed of the slowest installed memory module(s). The memory speeds are also dependent on the processor bin.

Two memory risers are allocated to each processor. The number of channels used and the allowable configurations depend on the memory mode selected.

The system supports memory mirroring if identical memory modules are installed in both the risers. Mirroring must be enabled in the System Setup program. In a mirrored configuration, the total available system memory is one-half of the total installed physical memory.

NOTE:

Memory sparing and mirroring are enabled only when memory configurations are greater than or equal to 64 GB.

92

Installing System Components

book.book Page 93 Wednesday, January 20, 2010 10:20 AM

Table 3-1.

Memory Configurations (Dual Processor)

CPU 1

Memory mode

Riser A (memory capacity in GB) Riser B (memory capacity in GB)

Total memory

(per processor)

/ total system memory

1

5

2

6

3

7

4

8

1

5

2

6

3

7

4

8

Power optimized 4 / 8

8 / 16

2

4

2

4

Not installed

Not installed

Performance optimized

Power and performance optimized

16 / 32

32 / 64

4 / 8

8 / 16

16 / 32

32 / 64

2 / 4

64 / 128

80 / 160

128 / 256

4

4 4 4 4 4 4 4 4 Not installed

1

1

2

4

1

4

1

1

2

4

1

4

1

2

4

4

1

2

4

Not installed

1

1

2

4

1

1

2

4

Not installed

1

2

4

1

2

4

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

8 8 4 4 4 4 4 4 8 8 4 4 4 4 4 4

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Installing System Components

93

book.book Page 94 Wednesday, January 20, 2010 10:20 AM

Memory mode

CPU 2

Riser A (memory capacity in GB) Riser B (memory capacity in GB)

Total memory

(per processor)

/ total system memory

1

5

2

6

3

7

4

8

1

5

2

6

3

7

4

8

Power optimized 4 / 8

8 / 16

16 / 32

32 / 64

Performance optimized

4 / 8

8 / 16

16 / 32

32 / 64

Power and performance optimized

2 / 4

64 / 128

80 / 160

128 / 256

2

4

1

1

2

4

2

4

Not installed

Not installed

4 4 4 4 Not installed

4 4 4 4 4 4 4 4 Not installed

1

1

2

4

1

2

4

1

2

4

1

1

2

4

2

4

1

1 1

2

4

1

2

4

1 1 Not installed

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

8 8 4 4 4 4 4 4 8 8 4 4 4 4 4 4

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

94

Installing System Components

book.book Page 95 Wednesday, January 20, 2010 10:20 AM

Table 3-2.

Memory Configurations (Four Processors)

CPU 1

Memory mode

Power optimized

Total memory (per processor) / total system memory

Riser A (memory capacity in GB)

1

5

2

6

3

7

4

8

4 / 16

8 / 32

16 / 64

32 / 128

2

4

2

4

Riser B (memory capacity in GB)

1

5

2

Not installed

Not installed

4 4 4 4 Not installed

4 4 4 4 4 4 4 4 Not installed

6

3

7

4

8

Performance optimized

40 / 160

48 / 192

4 / 16

8 / 32

16 / 64

32 / 128

48 / 192

2 / 8

8

1

2

4

1

1

8 8 4 4 4 4 4 4 Not installed

8 8 8 8 4 4 4 4 Not installed

1

1

2

4

8

1

1

2

4

4

1

2

4

4

1

1

2

4

8

1

1

2

4

8

Not installed

1

2

4

4

1

2

4

4

Power and performance optimized

64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Expandability

256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

32 / 128

64 / 256

8

8

8

8 8 8

8

8

8

8 8 8

128 / 512 16 16 16 16 16 16 16 16

Installing System Components

95

book.book Page 96 Wednesday, January 20, 2010 10:20 AM

CPU 2

Memory mode

Power optimized

Total memory (per processor) / total system memory

Riser A (memory capacity in GB)

1

5

2

6

3

7

4

8

4 / 16

8 / 32

16 / 64

32 / 128

2

4

2

4

Riser B (memory capacity in GB)

1

5

2

Not installed

Not installed

4 4 4 4 Not installed

4 4 4 4 4 4 4 4 Not installed

6

3

7

4

8

Performance optimized

40 / 160

48 / 192

4 / 16

8 / 32

16 / 64

32 / 128

48 / 192

2 / 8

8

1

2

4

1

1

8 8 4 4 4 4 4 4 Not installed

8 8 8 8 4 4 4 4 Not installed

1

1

2

4

8

1

1

2

4

4

1

2

4

4

1

1

2

4

8

1

1

2

4

8

Not installed

1

2

4

4

1

2

4

4

Power and performance optimized

64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Expandability

256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

32 / 128

64 / 256

8

8

8

8 8 8

8

8

8

8 8 8

128 / 512 16 16 16 16 16 16 16 16

96

Installing System Components

book.book Page 97 Wednesday, January 20, 2010 10:20 AM

CPU 3

Memory mode

Power optimized

Total memory (per processor) / total system memory

Riser A (memory capacity in GB)

1

5

2

6

3

7

4

8

4 / 16

8 / 32

16 / 64

32 / 128

2

4

2

4

Riser B (memory capacity in GB)

1

5

2

Not installed

Not installed

4 4 4 4 Not installed

4 4 4 4 4 4 4 4 Not installed

6

3

7

4

8

Performance optimized

40 / 160

48 / 192

4 / 16

8 / 32

16 / 64

32 / 128

48 / 192

2 / 8

8

1

2

4

1

1

8 8 4 4 4 4 4 4 Not installed

8 8 8 8 4 4 4 4 Not installed

1

1

2

4

8

1

1

2

4

4

1

2

4

4

1

1

2

4

8

1

1

2

4

8

Not installed

1

2

4

4

1

2

4

4

Power and performance optimized

64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Expandability

256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

32 / 128

64 / 256

8

8

8

8 8 8

8

8

8

8 8 8

128 / 512 16 16 16 16 16 16 16 16

Installing System Components

97

book.book Page 98 Wednesday, January 20, 2010 10:20 AM

CPU 4

Memory mode

Power optimized

Total memory (per processor) / total system memory

Riser A (memory capacity in GB)

1

5

2

6

3

7

4

8

4 / 16

8 / 32

16 / 64

32 / 128

2

4

2

4

Riser B (memory capacity in GB)

1

5

2

Not installed

Not installed

4 4 4 4 Not installed

4 4 4 4 4 4 4 4 Not installed

6

3

7

4

8

Performance optimized

40 / 160

48 / 192

4 / 16

8 / 32

16 / 64

32 / 128

48 / 192

2 / 8

8

1

2

4

1

1

8 8 4 4 4 4 4 4 Not installed

8 8 8 8 4 4 4 4 Not installed

1

1

2

4

8

1

1

2

4

4

1

2

4

4

1

1

2

4

8

1

1

2

4

8

Not installed

1

2

4

4

1

2

4

4

Power and performance optimized

64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Expandability

256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

32 / 128

64 / 256

8

8

8

8 8 8

8

8

8

8 8 8

128 / 512 16 16 16 16 16 16 16 16

98

Installing System Components

book.book Page 99 Wednesday, January 20, 2010 10:20 AM

Removing a Memory-Riser Blank

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Press the release tabs toward each other and lift the memory-riser blank out of the system.

Figure 3-6.

Removing and Installing a Memory-Riser Blank

2

1

1 release tabs (2) 2 memory-riser blank

Installing System Components

99

book.book Page 100 Wednesday, January 20, 2010 10:20 AM

100

Installing a Memory-Riser Blank

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Align the memory-riser blank with the slots on the memory-riser guide and the cooling fan assembly.

2 Insert the memory-riser blank firmly into the card guide until it is fully seated.

3 Close the system. See "Closing the System" on page 90.

4 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Removing a Memory Riser

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Press the release button on the memory riser to release the handle.

4 Grasp the handle and lift the memory riser out of the system.

CAUTION:

To maintain proper system cooling, all empty memory-riser slots must have memory-riser blanks installed.

5 Install a memory-riser blank. See "Installing a Memory-Riser Blank" on page 100.

6 Close the system. See "Closing the System" on page 90.

7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing System Components

book.book Page 101 Wednesday, January 20, 2010 10:20 AM

Figure 3-7.

Removing and Installing a Memory Riser

1

2

3

5

4

1 handle 2 memory

3 release button

5 memory-riser connector

4 card guide

Installing a Memory Riser

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the memory-riser blank. See "Removing a Memory-

Riser Blank" on page 99.

CAUTION:

Before installing the memory riser, you must ensure that the memory module socket ejectors are in the locked position.

Installing System Components

101

book.book Page 102 Wednesday, January 20, 2010 10:20 AM

4 Align the memory riser with the slots on the memory-riser guide and the cooling fan assembly.

5 Insert the memory riser firmly into the card guide until it is fully seated.

6 Press down on the handle until it clicks into place.

NOTE:

You can only lower the handle after the memory riser is seated in the card guide. If the handle does not move down, verify that the memory riser is properly seated in the card guide.

7 Close the system. See "Closing the System" on page 90.

8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing Memory Modules

WARNING:

The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Remove the memory risers. See "Removing a Memory Riser" on page 100.

4 Pull the release tab and lift the memory module cover in the direction of the arrow.

102

Installing System Components

book.book Page 103 Wednesday, January 20, 2010 10:20 AM

Figure 3-8.

Removing and Installing the Memory Module Cover

1

2

1 release tab 2 memory module cover

CAUTION:

Handle each memory module only on either card edge, making sure not to touch the middle of the memory module.

5 Press the ejectors on the memory module socket down and out, as shown

in Figure 3-9.

Installing System Components

103

book.book Page 104 Wednesday, January 20, 2010 10:20 AM

Figure 3-9.

Installing and Removing a Memory Module

1

2

3

104

1 memory module

3 alignment key

2 memory module socket ejectors (2)

6 Align the memory module's edge connector with the alignment key of the memory module socket, and insert the memory module in the socket.

NOTE:

The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way.

7 Press down on the memory module with your thumbs to lock the memory module into the socket.

When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that have memory modules installed.

8 Repeat step 5 through step 7 of this procedure to install the remaining

memory modules. See Table 3-1 and Table 3-2.

9 Close the memory module cover.

10 Install the memory risers. See "Installing a Memory Riser" on page 101.

11 Close the system. See "Closing the System" on page 90.

Installing System Components

book.book Page 105 Wednesday, January 20, 2010 10:20 AM

12 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

13 Press <F2> to enter the System Setup program, and check the System

Memory setting on the main System Setup screen.

The system should have already changed the value to reflect the newly installed memory.

14 If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 2 through step 13 of this procedure to ensure that the memory modules are firmly seated in their sockets.

15 Run the system memory test in the system diagnostics. See "Running the

Embedded System Diagnostics" on page 194.

Removing Memory Modules

WARNING:

The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION:

To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Remove the memory risers. See "Removing a Memory Riser" on page 100.

4 Press the tabs in the direction of the arrows and lift the memory module cover.

CAUTION:

Handle each memory module only on either card edge, making sure not to touch the middle of the memory module.

Installing System Components

105

book.book Page 106 Wednesday, January 20, 2010 10:20 AM

5 Press down and out on the ejectors on each end of the socket until the

memory module pops out of the socket. See Figure 3-9.

6 Close the memory module cover.

7 Install the memory risers. See "Installing a Memory Riser" on page 101.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system and peripherals to their power sources, and turn them on.

Removing the Memory-Riser Guide

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

4 Remove the memory risers. See "Removing a Memory Riser" on page 100.

5 Press the tabs in the direction of the arrows and lift the memory-riser guide out of the system.

Figure 3-10.

Removing or Installing the Memory-Riser Guide

1

2

106

1 memory-riser guide

Installing System Components

2 tabs (2)

book.book Page 107 Wednesday, January 20, 2010 10:20 AM

Installing the Memory-Riser Guide

1 Align the memory-riser guide with the slots on the chassis.

2 Lower the memory-riser guide into the system until the tabs click into place.

3 Install the memory risers. See "Installing a Memory Riser" on page 101.

4 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

5 Close the system. See "Closing the System" on page 90.

6 Reconnect the system and peripherals to their power sources, and turn them on.

Hard Drives

All drives connect to the system board through the SAS/SATA backplane board. Hard drives are supplied in special hot-swappable drive carriers that fit in the hard-drive bays.

CAUTION:

Before attempting to remove or install a drive while the system is running, see the documentation for the SAS controller card to ensure that the host adapter is configured correctly to support hot-swap drive removal and insertion.

CAUTION:

Do not turn off or reboot your system while the drive is being formatted.

Doing so can cause a drive failure.

NOTE:

Use only drives that have been tested and approved for use with the

SAS/SATA backplane board.

When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to format.

Installing System Components

107

book.book Page 108 Wednesday, January 20, 2010 10:20 AM

Removing a Hard-Drive Blank

CAUTION:

To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed.

1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.

2 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

3 Press the release tab and slide the drive blank out until it is free of the drive

bay. See Figure 3-11.

Figure 3-11.

Removing or Installing a Hard-Drive Blank

1

2

1 hard-drive blank 2 release tab

Installing a Hard-Drive Blank

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 Insert the drive blank into the drive bay until the blue release tab clicks into place.

3 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

108

Installing System Components

book.book Page 109 Wednesday, January 20, 2010 10:20 AM

Removing a Hard Drive

CAUTION:

Ensure that your operating system supports hot-swap drive installation. See the documentation supplied with the operating system.

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 From the management software, prepare the drive for removal. Wait until the hard-drive indicators on the drive carrier signal that the drive can be removed safely. See your controller documentation for information about hot-swap drive removal.

If the drive has been online, the green activity/fault indicator flashes as the drive is powered down. When the drive indicators are off, the drive is ready for removal.

3 Open the drive carrier release handle to release the drive. See

Figure 3-12.

4 Slide the hard drive out until it is free of the drive bay.

CAUTION:

To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed.

5 Insert a drive blank in the empty drive bay. See "Installing a Hard-Drive

Blank" on page 108.

6 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

Installing System Components

109

book.book Page 110 Wednesday, January 20, 2010 10:20 AM

Figure 3-12.

Removing and Installing a Hard Drive

1

2

1 release button 2 hard drive carrier handle

Installing a Hard Drive

CAUTION:

Use only hard drives that have been tested and approved for use with the SAS/SATA backplane.

CAUTION:

When installing a hard drive, ensure that the adjacent drives are fully installed. Inserting a hard-drive carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable.

CAUTION:

Ensure that your operating system supports hot-swap drive installation. See the documentation supplied with your operating system.

CAUTION:

Combining SATA and SAS hard drives in the same system configuration is not supported.

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 If a drive blank is present in the bay, remove it. See "Removing a Hard-

Drive Blank" on page 108.

110

Installing System Components

book.book Page 111 Wednesday, January 20, 2010 10:20 AM

NOTE:

If you are upgrading your system to a 16 –hard-drive configuration, turn off the system and remove all the chassis blanks. To remove the chassis blank, press down and push the blue release tab toward the front of the system. See

Figure 3-13.

3 Press the button on the front of the drive carrier and open the handle.

4 Insert the hard-drive carrier into the drive bay until the carrier contacts the backplane.

5 Close the handle to lock the drive in place.

Figure 3-13.

Removing a Chassis Blank

2

1

1 chassis blank 2 release tab

Installing System Components

111

book.book Page 112 Wednesday, January 20, 2010 10:20 AM

Removing a Hard Drive From a Hard-Drive Carrier

Remove the screws from the slide rails on the hard-drive carrier and separate

the hard drive from the carrier. See Figure 3-14.

Figure 3-14.

Removing or Installing a Hot-Swap Hard Drive Into a Drive Carrier

4

1

2

1 screws (4)

3 SAS/SATA screw hole

2 drive carrier

4 hard drive

3

112

Installing System Components

book.book Page 113 Wednesday, January 20, 2010 10:20 AM

Installing a Hard Drive Into a Drive Carrier

1 Insert the hard drive into the hard-drive carrier with the connector end

of the drive at the rear. See Figure 3-14.

2 Align the screw holes on the hard drive with the back set of holes on the hard drive carrier.

When aligned correctly, the back of the hard drive will be flush with the back of the hard-drive carrier.

3 Attach the four screws to secure the hard drive to the hard-drive carrier.

Optical Drive

An optional DVD +/-RW optical drive slides into the front panel and connects to the SATA controller on the system board.

NOTE:

DVD devices are data only.

Removing an Optical Drive

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 If applicable, remove the memory risers H, G, and D. See "Removing a

Memory Riser" on page 100. For the location of memory risers H, G, and D

on the system, see Figure 3-5.

5 Disconnect the power/data cable from the back of the drive.

Note the routing of the power/data cable on the side on the system as you remove them from the system board and drive. You must route these cables properly when you replace them to prevent them from being pinched or crimped.

Installing System Components

113

book.book Page 114 Wednesday, January 20, 2010 10:20 AM

6 To remove the drive, press down and push the blue release tab toward the

front of the system. See Figure 3-15.

7 Slide the optical drive out of the system until it is free of the drive bay.

8 If you are not adding a new optical drive, install the optical drive insert.

9 If applicable, install the memory risers H, G, and D. See "Installing a

Memory Riser" on page 101.

10 Close the system. See "Closing the System" on page 90.

11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

12 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

Figure 3-15.

Removing the Optical Drive

2

3

1

1 optical drive

3 release tab

114

Installing System Components

2 power/data cable

book.book Page 115 Wednesday, January 20, 2010 10:20 AM

Installing an Optical Drive

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 If applicable, remove the memory risers H, G, and D. See "Removing a

Memory Riser" on page 100.

5 Slide the optical drive into the optical drive bay until the blue release tab

snaps into place. See Figure 3-15.

6 Connect the power/data cable to the back of the drive.

You must route the cable properly on the side of system to prevent it from being pinched or crimped.

7 If not already done, connect the power cable to SATA_PWR and the

interface cable to SATA_A connector on the system board. See Figure 6-1.

8 If applicable, install the memory risers H, G, and D. See "Installing a

Memory Riser" on page 101. For the location of memory risers H, G, and D

on the system, see Figure 3-5.

9 Close the system. See "Closing the System" on page 90.

10 Reconnect the system and peripherals to their electrical outlets.

11 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

Installing System Components

115

book.book Page 116 Wednesday, January 20, 2010 10:20 AM

Cooling Fans

Your system contains six single-rotor hot-swappable fans to provide cooling for the processors, expansion cards, and memory modules.

NOTE:

In the event of a problem with a particular fan, the fan number is referenced by the system’s management software, allowing you to easily identify and replace the proper fan by noting the fan numbers on the fan assembly.

Removing a Cooling Fan

WARNING:

The cooling fan can continue to spin for some time after it has been powered down. Allow time for the fan to stop spinning before removing it from the system.

WARNING:

Do not attempt to operate the system without the cooling fans or the cover.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

The procedure for removing each individual fan module is the same.

1 Open the system. See "Opening the System" on page 89.

2 Press the release tabs toward each other and lift the fan out of the fan

assembly. See Figure 3-16.

116

Installing System Components

book.book Page 117 Wednesday, January 20, 2010 10:20 AM

Figure 3-16.

Removing and Installing a Cooling Fan

1

2

3

1 release tab (2)

3 cooling fan assembly

2 cooling fan

Installing a Cooling Fan

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Align the connector on the fan with the connector on the system board.

2 Lower the fan into the fan assembly until the release tabs snap into place.

See Figure 3-16.

3 Close the system. See "Closing the System" on page 90.

Installing System Components

117

book.book Page 118 Wednesday, January 20, 2010 10:20 AM

Removing the Cooling Fan Assembly

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

4 Remove the memory risers. See "Removing a Memory Riser" on page 100.

5 Remove the fans from the cooling fan assembly. See "Removing a Cooling

Fan" on page 116.

6 Pull the blue release tabs in the direction of the arrows to release the

handles on the cooling fan assembly. See Figure 3-17.

7 Grasp the handles and lift the cooling fan assembly out of the system. See

Figure 3-17.

118

Installing System Components

book.book Page 119 Wednesday, January 20, 2010 10:20 AM

Figure 3-17.

Removing and Installing the Fan Assembly

1

2

3

1 handles (2)

3 release tabs (2)

2 cooling fan assembly

Installing System Components

119

book.book Page 120 Wednesday, January 20, 2010 10:20 AM

Installing the Cooling Fan Assembly

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Align the tabs on the cooling fan assembly with the slots on the system.

See Figure 3-17.

NOTE:

You must also ensure that the pins on the bottom of the cooling fan assembly are aligned with the holes on the system board.

2 Insert the cooling fan assembly into the system and lower the handles to lock it in place.

3 Install the cooling fans. See "Installing the Cooling Fan Assembly" on page 120.

4 Install the memory risers. See "Installing a Memory Riser" on page 101.

5 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

6 Close the system. See "Closing the System" on page 90.

7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Internal USB Memory Key

An optional USB memory key installed inside your system can be used as a boot device, security key, or mass storage device. The USB connector must be enabled by the Internal USB Port option in the Integrated Devices screen of the System Setup program.

To boot from the USB memory key, configure the USB memory key with a boot image and then specify the USB memory key in the boot sequence in the

System Setup program.

120

Installing System Components

book.book Page 121 Wednesday, January 20, 2010 10:20 AM

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Locate the USB connector on the system board.

4 Insert the USB memory key into the USB connector. See Figure 3-18.

5 Close the system. See "Closing the System" on page 90.

6 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

7 Enter the System Setup program and verify that the USB key has been

detected by the system. See "Using the System Setup Program and UEFI

Boot Manager" on page 63.

Installing System Components

121

book.book Page 122 Wednesday, January 20, 2010 10:20 AM

Figure 3-18.

Removing and Installing a USB Memory Key

1

2

1 USB memory key 2 USB memory key connector

122

Installing System Components

book.book Page 123 Wednesday, January 20, 2010 10:20 AM

Integrated NIC Hardware Key

TCP/IP Offload Engine (TOE) and iSCSI are enabled by default on the system. The integrated NIC hardware key is reserved for future use.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

TOE operating system support and the Microsoft

® scalable network pack are required for TOE functionality.

1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Locate the iSCSI_KEY connector on the system board. See Figure 6-1.

4 Insert the NIC hardware key into the connector onto the board. See

Figure 3-19.

Installing System Components

123

book.book Page 124 Wednesday, January 20, 2010 10:20 AM

Figure 3-19.

Removing or Installing a NIC Hardware Key

1

2

124

1 NIC hardware key 2 iSCSI_KEY connector

5 Close the system. See "Closing the System" on page 90.

6 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Expansion Cards and Expansion-Card Riser

Expansion Card Installation Guidelines

Your system supports one Generation 1 PCIe expansion card and up to six

Generation 2 PCIe expansion cards.

• The expansion slot supports full-height, half-length cards.

• The expansion-card slot is not hot-swappable.

• PCI Express Generation 2 slots support both PCI Express Generation 1 and PCI Express Generation 2 cards. However, using a PCI Express

Generation 2 card on an PCI Express Generation 1 slot may impact performance of the card.

Installing System Components

book.book Page 125 Wednesday, January 20, 2010 10:20 AM

• PCI Express Generation 1 is supported on slot 5 and Generation 2 expansion cards are supported in the slots 1, 2, 3, 4, 6, and 7.

• Slot 7 can be expanded to four additional PCIe x4 Generation 2 low profile slots using an optional PCIe expansion riser.

• Table 3-3 provides a guide for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All other expansion cards should be installed in card priority and slot priority order.

Table 3-3.

Expansion-Card Installation Order

Card

Priority

1

2

3

4

5

6

7

8

9

10

Card Type

PERC H800

6 Gbps SAS HBA

SAS 5/E Adapter

10 Gb NICs

8G Fiber Channel

(single port)

8G Fiber Channel

(dual port)

4G Fibre Channel

SCSI HBA

1 Gb NICs

(Generation 1 adapters)

1 Gb NICs

(Generation 2 adapters)

Slot Priority

Without a PCIe

Riser

Slot Priority With a PCIe Riser

2, 3, 4, 6, 1 2, 3, 4, 6,

7, 1

2, 3, 4, 6,

7, 1

2, 3, 4, 6,

7

2, 3, 4, 6,

7

1, 2, 3, 4,

6, 7

2, 3, 4, 6,

7

5, 1, 2, 3,

4, 6, 7

5, 1, 2, 3,

4, 6, 7

5, 1, 2, 3,

4, 6, 7, 1

5, 1, 2, 3,

4, 6, 7, 1

2, 3, 4, 6, 1

2, 3, 4, 6

2, 3, 4, 6

1, 7, 8, 9, 10,

2, 3, 4, 6

2, 3, 4, 6

5, 1, 7, 8, 9,

10, 2, 3, 4, 6

5, 1, 7, 8, 9,

10, 2, 3, 4, 6

5, 1, 7, 8, 9, 10,

2, 3, 4, 6

1, 7, 8, 9, 10, 5,

2, 3, 4, 6

Max

Allowed

2

2

2

2

4

2

4–6

2

10

10

Installing System Components

125

book.book Page 126 Wednesday, January 20, 2010 10:20 AM

Installing an Expansion Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Unpack the expansion card and prepare it for installation.

For instructions, see the documentation accompanying the card.

2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 Open the expansion-card latch and remove the filler bracket. See

Figure 3-20.

5 Holding the card by its edges, position the card so that the card-edge connector aligns with the expansion-card connector.

6 Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.

7 Close the expansion-card latch. See Figure 3-20.

8 If applicable, install the screw to secure the expansion card to the system.

126

Installing System Components

book.book Page 127 Wednesday, January 20, 2010 10:20 AM

Figure 3-20.

Installing or Removing an Expansion Card

1 2

3

4

1 expansion-card latch

3 expansion card

2 screw

4 expansion-card connector

Installing System Components

127

book.book Page 128 Wednesday, January 20, 2010 10:20 AM

9 If applicable, connect any cables to the expansion card.

10 Close the system. See "Closing the System" on page 90.

11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

12 Install any device drivers required for the card as described in the documentation for the card.

Removing an Expansion Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, disconnect all the cables from the card.

4 If applicable, remove the screw that secures the expansion card to the system.

5 To remove the expansion card, open the expansion-card latch.

See Figure 3-20.

6 Grasp the expansion card by its edges, and carefully remove it from the expansion-card connector.

7 If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.

NOTE:

You must install a filler bracket over an empty expansion slot to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

128

Installing System Components

book.book Page 129 Wednesday, January 20, 2010 10:20 AM

Installing an Expansion-Card Riser

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Unpack the expansion-card riser and prepare it for installation.

2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 Pull the latch toward the front of the system and lift the expansion-card

panel out of the system. See Figure 3-21.

5 To add expansion cards on the expansion-card riser, press the tabs toward

each other and open the expansion-card latch. See Figure 3-22.

6 Holding the card by its edges, position the card so that the card-edge connector aligns with the connector on the expansion-card riser.

7 Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.

8 Close the expansion-card latch.

9 Align the expansion-card riser with the slots on the chassis.

See Figure 3-23.

10 Lower the expansion-card riser until the riser is fully seated in the

connector and the latch clicks into place. See Figure 3-23.

11 Close the system. See "Closing the System" on page 90.

12 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

13 Install any device drivers required for the card as described in the documentation for the card.

Installing System Components

129

book.book Page 130 Wednesday, January 20, 2010 10:20 AM

Figure 3-21.

Removing and Installing the Panel

1

2

1 latch 2 panel

130

Installing System Components

book.book Page 131 Wednesday, January 20, 2010 10:20 AM

Figure 3-22.

Removing and Installing an Expansion Card in an Expansion-Card Riser

3

4

2

1

1 expansion-card riser

3 tabs (2)

2 expansion card

4 expansion-card latch

Installing System Components

131

book.book Page 132 Wednesday, January 20, 2010 10:20 AM

Figure 3-23.

Removing and Installing an Expansion-Card Riser

1

2

3

1 release tabs (2)

3 expansion-card riser connector

2 expansion-card riser

132

Installing System Components

book.book Page 133 Wednesday, January 20, 2010 10:20 AM

Removing an Expansion-Card Riser

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 To remove the expansion-card riser, press the release tabs toward each

other and lift the expansion-card riser out of the system. See Figure 3-23.

4 Press the tabs toward each other and open the expansion-card latch. See

Figure 3-22.

5 Grasp the expansion-card by its edges, and carefully remove it from the expansion-card connector on the riser.

6 If you are removing the expansion-card riser permanently, install the panel

in the system. See Figure 3-21.

NOTE:

You must install the panel over an empty expansion slot to maintain

Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

7 Close the system. See "Closing the System" on page 90.

8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing System Components

133

book.book Page 134 Wednesday, January 20, 2010 10:20 AM

I/O Card

Removing the I/O Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 If applicable, disconnect the external cables connected to the I/O card.

3 Open the system. See "Opening the System" on page 89.

4 Grasp the card by its edges and lift the card to remove it from the I/O card

connector. See Figure 3-1 for the location of the I/O card in the system.

5 If applicable, remove the internal dual SD module. See "Removing the

Internal Dual SD Module" on page 139.

6 If applicable, remove the iDRAC6 enterprise card. See "Removing an iDRAC6 Enterprise Card" on page 138.

134

Installing System Components

book.book Page 135 Wednesday, January 20, 2010 10:20 AM

Figure 3-24.

Removing and Installing the I/O Card

1

2

1 I/O card 2 I/O card connector

Installing the I/O Card

1 If applicable install the iDRAC6 Enterprise card. See "Installing an iDRAC6 Enterprise Card" on page 136.

2 If applicable, install the internal dual SD module. See "Installing the

Internal Dual SD Module" on page 141.

3 Holding the card by its edges, position the card so that the card-edge connector aligns with the I/O card connector.

4 Insert the card-edge connector firmly into the I/O card connector until the card is fully seated.

Installing System Components

135

book.book Page 136 Wednesday, January 20, 2010 10:20 AM

5 Close the system. See "Closing the System" on page 90.

6 If applicable, reconnect the external cables to the I/O card.

7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

iDRAC6 Enterprise Card (Optional)

Installing an iDRAC6 Enterprise Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Remove the I/O card. See "Removing the I/O Card" on page 134.

4 Remove the plastic filler plug for the iDRAC6 Enterprise port from the

I/O card.

5 Align the front edge of the card with the two front plastic retention standoffs next to the iDRAC6 connector on the system board, and lower

the card into place. See Figure 3-25.

When the front of the card is fully seated, the plastic standoffs snap over the edge of the card.

136

Installing System Components

book.book Page 137 Wednesday, January 20, 2010 10:20 AM

Figure 3-25.

Installing or Removing an iDRAC6 Enterprise Card (Optional)

2

1

3

4

5

1 iDRAC6 Enterprise card

3 retention standoff tabs (2)

5 iDRAC6 Enterprise card connector

2 VFlash media slot

4 retention standoff posts (2)

6 Install the I/O card. See "Installing the I/O Card" on page 135.

7 Close the system. See "Closing the System" on page 90.

8 Reconnect the system and peripherals to their power sources, and turn them on.

Installing System Components

137

book.book Page 138 Wednesday, January 20, 2010 10:20 AM

Removing an iDRAC6 Enterprise Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 If applicable, disconnect the Ethernet cable from the iDRAC6 Enterprise

Card connector on the system back panel. See Figure 1-3.

3 Open the system. See "Opening the System" on page 89.

4 Remove the I/O card. See "Removing the I/O Card" on page 134.

5 If applicable, remove the VFlash media card from the iDRAC6 Enterprise

Card. See "Removing a VFlash Media Card" on page 139.

6 Pull back slightly on the two tabs at the front edge of the card and gently lift the front edge of the card off of the retention standoffs.

As the card releases from the standoffs, the connector under the card disengages from the system board connector.

7 Install the plastic filler plug over the port on the I/O card.

8 Install the I/O card. See "Installing the I/O Card" on page 135.

9 Close the system. See "Closing the System" on page 90.

10 Reconnect the system and peripherals to their power sources, and turn them on.

138

Installing System Components

book.book Page 139 Wednesday, January 20, 2010 10:20 AM

VFlash Media (Optional)

The VFlash media card is a Secure Digital (SD) card that plugs into the optional iDRAC6 Enterprise card at the back corner of the system.

Installing a VFlash Media Card

1 Locate the VFlash media slot at the back corner of the system.

2 With the label side facing up, insert the contact-pin end of the SD card into the card slot on the module.

NOTE:

The slot is keyed to ensure correct insertion of the card.

3 Press inward on the card to lock it into the slot.

Removing a VFlash Media Card

To remove the VFlash media, push inward on the card to release it, and pull the card from the card slot.

Internal Dual SD Module (Optional)

NOTE:

When the Redundancy option is set to Mirror Mode in the Integrated

Devices screen of the system setup, the information is replicated from one SD card to another.

Removing the Internal Dual SD Module

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the SD card(s). See "Removing an Internal SD Card" on page 142.

4 Remove the I/O card. See "Removing the I/O Card" on page 134.

Installing System Components

139

book.book Page 140 Wednesday, January 20, 2010 10:20 AM

5 Disconnect the SD module cable.

6 Pull back slightly on the tabs at the edge of the card and gently lift the edge of the card off of the retention standoffs.

7 Install the I/O card. See "Installing the I/O Card" on page 135.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system and peripherals to their power sources, and turn them on.

Figure 3-26.

Removing and Installing the Internal Dual SD Module

3

4

2

1

1 retention standoff posts (3)

3 SD module cable

2 retention standoff tabs (3)

4 dual SD module

140

Installing System Components

book.book Page 141 Wednesday, January 20, 2010 10:20 AM

Installing the Internal Dual SD Module

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Remove the I/O card. See "Removing the I/O Card" on page 134.

4 Align the card with the plastic retention standoffs on the I/O card, and

lower the card into place. See Figure 3-25.

When the front of the card is fully seated, the plastic standoffs snap over the edge of the card.

5 Connect the SD module cable to the connector on the I/O card.

6 Install the I/O card. See "Installing the I/O Card" on page 135.

7 If applicable, install the SD card(s). See "Installing an Internal SD Card" on page 142.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system and peripherals to their power sources, and turn them on.

Installing System Components

141

book.book Page 142 Wednesday, January 20, 2010 10:20 AM

Internal SD Card (Optional)

Installing an Internal SD Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

To use an SD card with your system, ensure that the internal SD card port is

enabled in the System Setup program. See "Using the System Setup Program and

UEFI Boot Manager" on page 63.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Locate the SD card connector on the internal dual SD module. With the label side facing up, insert the contact-pin end of the card into the slot.

NOTE:

The slot is keyed to ensure correct insertion of the card.

4 Press the card into the card slot to lock it into place.

5 Close the system. See "Closing the System" on page 90.

6 Reconnect the system and peripherals to their power sources, and turn them on.

Removing an Internal SD Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

142

Installing System Components

book.book Page 143 Wednesday, January 20, 2010 10:20 AM

3 Locate the SD card slot on the internal dual SD module and press inward on the card to release it from the slot and remove the card.

4 Close the system. See "Closing the System" on page 90.

5 Reconnect the system and peripherals to their power sources, and turn them on.

Integrated Storage Controller Card

Your system includes a dedicated expansion-card slot on the system board for an integrated controller card that provides the integrated storage subsystem for your system’s internal hard drives. The controller supports SAS and SATA hard drives and also enables you to set up the hard drives in RAID configurations as supported by the version of the storage controller included with your system.

Removing the Integrated Storage Controller Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Remove the I/O card. See "Removing the I/O Card" on page 134.

4 Disconnect the cables connected to the storage controller card. See

Figure 3-1 for the location of the integrated storage controller card in

the system.

5 Grasp the card by its edges and lift the card to remove it from the connector on the system board.

6 Install the I/O card. See "Installing the I/O Card" on page 135

7 Close the system. See "Closing the System" on page 90.

8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing System Components

143

book.book Page 144 Wednesday, January 20, 2010 10:20 AM

Figure 3-27.

Installing the Integrated Storage Controller Card

1

2

3

5

4

1 battery cable

3 integrated storage controller card

5 clip

2 SAS data cables (2)

4 integrated storage controller card connector

144

Installing System Components

book.book Page 145 Wednesday, January 20, 2010 10:20 AM

Installing the Integrated Storage Controller Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Remove the I/O card. See "Removing the I/O Card" on page 134.

4 Hold the card by its edges and insert the card-edge connector firmly into the connector until the card is fully seated and the plastic card guides fit over the edges of the card.

5 Connect the SAS data cable connector to the integrated storage controller

card. See Figure 3-27.

NOTE:

You must ensure that you connect the cable according to the connector labels on the cable. The cable does not function properly if reversed.

6 Route the SAS data cable through the clip on the card and through the channel on the inner side of the chassis.

7 Attach the connector labeled "SAS A" to connector SAS A on the backplane, and attach the connector labeled "SAS B" to connector SAS B

on the backplane. See Figure 3-27.

8 Install the I/O card. See "Installing the I/O Card" on page 135.

9 Close the system. See "Closing the System" on page 90.

10 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing System Components

145

book.book Page 146 Wednesday, January 20, 2010 10:20 AM

RAID Battery

The information in this section applies only to systems with the optional

PERC controller card.

Removing a RAID Battery

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

4 Remove the memory risers. See "Removing a Memory Riser" on page 100.

5 Remove the memory-riser guide. See "Removing the Memory-Riser Guide" on page 106.

6 Pull back gently on the right edge of the battery carrier and lift the RAID

battery from the battery carrier. See Figure 3-28.

7 Disconnect the RAID battery cable from the RAID battery.

146

Installing System Components

book.book Page 147 Wednesday, January 20, 2010 10:20 AM

Figure 3-28.

Removing or Installing the RAID Battery

2

3

1

1 battery carrier

3 RAID battery

2 RAID battery cable

Installing the RAID Battery

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Connect the battery cable to the integrated storage controller card.

2 Route the battery cable/SAS A cable along the chassis wall.

3 Connect the battery cable to the RAID battery.

Installing System Components

147

book.book Page 148 Wednesday, January 20, 2010 10:20 AM

148

4 Insert the RAID battery into the battery carrier. See Figure 3-28.

NOTE:

While installing the RAID battery into the battery carrier, you must ensure that the RAID battery cable faces the chassis wall.

5 Install the memory-riser guide. See "Installing the Memory-Riser Guide" on page 107.

6 Install the memory risers. See "Installing a Memory Riser" on page 101.

7 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Processors

Removing a Processor

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Prior to upgrading your system, download the latest system BIOS version from support.dell.com and follow the instructions included in the compressed download file to install the update on your system.

2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. When disconnected from AC power, press and hold the power button for three seconds to fully drain the system of stored power prior to removing the cover.

NOTE:

It is recommended that you always use a static mat and static strap while working on components in the interior of the system.

3 Open the system. See "Opening the System" on page 89.

4 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

5 Remove the memory risers. See "Removing a Memory Riser" on page 100.

Installing System Components

book.book Page 149 Wednesday, January 20, 2010 10:20 AM

6 Remove the cooling fan assembly. See "Removing the Cooling Fan

Assembly" on page 118.

WARNING:

The heat sink and processor are hot to touch for some time after the system has been powered down. Allow the heat sink and processor to cool before handling them.

CAUTION:

Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions.

7 Release one of the heat-sink release levers. See Figure 3-29.

8 Wait 30 seconds for the heat sink to loosen from the processor.

9 Release the other heat-sink release lever.

10 Gently lift the heat sink off of the processor and set the heat sink aside upside down (thermal grease side facing up).

Installing System Components

149

book.book Page 150 Wednesday, January 20, 2010 10:20 AM

Figure 3-29.

Installing and Removing the Heat Sink

2

1

1 release levers (2) 2 heat sink

CAUTION:

The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped.

11 Position your thumb firmly over the processor socket-release lever and release the lever from the locked position by pushing down and pulling out from under the tab. Rotate the lever 90 degrees upward until the processor

is released from the socket. See Figure 3-29.

12 Use the tab on the processor shield to rotate shield upward and out of the

way. See Figure 3-29.

150

Installing System Components

book.book Page 151 Wednesday, January 20, 2010 10:20 AM

CAUTION:

Be careful not to bend any of the pins on the ZIF socket when removing the processor. Bending the pins can permanently damage the system board.

13 Carefully lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor.

After removing the processor, place it in an antistatic container for reuse, return, or temporary storage. Do not touch the bottom of the processor.

Touch only the side edges of the processor.

Figure 3-30.

Removing and Installing a Processor

4

5

2

3

1

6

Installing System Components

151

book.book Page 152 Wednesday, January 20, 2010 10:20 AM

1 socket-release lever

3 pin 1 indicators (2)

5 notch in processor (2)

2 processor shield

4 processor

6 ZIF socket

Installing a Processor

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

In a dual-processor configuration, CPU 1 and CPU 2 sockets must be used.

1 If you are adding a processor for the first time, remove the socket cover.

See Figure 3-31.

Figure 3-31.

Removing the Processor Socket Cover

1

2

152

1 processor cover

Installing System Components

2 processor socket

book.book Page 153 Wednesday, January 20, 2010 10:20 AM

2 Remove the processor from the packing material by the processor’s edges only. Do not touch the bottom of the processor. Handle the processor carefully with your fingers on the side edges. Place your hand beneath the processor when you are moving it to the system.

3 Locate the pin 1 indicator on the system board socket.

4 Locate the pin 1 indicator on the top of the processor. The pin 1 indicator

is shown as a triangle on the top of the processor. See Figure 3-30.

CAUTION:

Positioning the processor incorrectly can permanently damage the system board or the processor. Be careful not to bend the pins in the socket.

5 Place the processor over the socket with each pin 1 aligned and level. See

Figure 3-30.

6 Align the notches in the processor with the socket keys on the ZIF

socket. See Figure 3-30.

7 Install the processor in the socket. Keep the processor level (see

Figure 3-30) and insert it straight down into the socket. Allow the

processor to float on the pins, allowing the processor shield to hold it in place.

8 Verify that the processor is properly aligned and seated.

9 Close the processor shield. See Figure 3-30.

10 Rotate the socket-release lever down until it snaps into place. See

Figure 3-30.

11 Using a clean lint-free cloth, remove the thermal grease from the heat sink.

CAUTION:

Applying too much thermal grease can result in excess grease coming in contact with and contaminating the processor socket.

12 Open the grease applicator included with your processor kit and apply all of the thermal grease in the applicator to the center of the topside of the new processor.

13 Place the heat sink on the processor. See Figure 3-29.

14 Close the heat-sink release levers. See Figure 3-29.

15 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.

16 Install the memory risers. See "Installing a Memory Riser" on page 101.

Installing System Components

153

book.book Page 154 Wednesday, January 20, 2010 10:20 AM

17 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

18 Close the system. See "Closing the System" on page 90.

19 Reconnect your system and peripherals to their electrical outlets, and turn on the system.

Power Supplies

Your system supports the following power supply modules:

• 1100 W (high output power supply)

• 750 W (energy smart power supply)

When a 10 Gb I/O card is installed, the system must have at least two power supplies connected to an A/C power supply. The system requires two power supplies to provide standby power to the system. With a 1 GbE I/O card, only

one PSU is required to provide standby power to the system. Table 3-4 and

Table 3-5 lists the power supply redundancy modes for a 10 Gb I/O card and a

1 GbE I/O card.

Table 3-4.

Power Supply Redundancy Modes With a 10 Gb I/O Card

Number of Power Supplies Redundancy Mode

1 1+0*

2

3

4

2+0

2+0

2+2

* indicates that the system operates with a limited load.

System Configuration

Non-redundant configuration with inactive

SFP+ ports

Non-redundant configuration

Non-redundant configuration

Redundant configuration

154

Installing System Components

book.book Page 155 Wednesday, January 20, 2010 10:20 AM

Table 3-5.

Power Supply Redundancy Modes With a 1 GbE I/O Card

3

4

2

2

Number of Power Supplies Redundancy Mode

1 1+0*

1+1*

2+0

2+1

2+2

*indicates that the system operates with a limited load.

System Configuration

Non-redundant configuration

Redundant configuration

Non-redundant configuration

Redundant configuration

Redundant configuration

Removing a Power Supply

CAUTION:

The system requires one power supply to operate the system normally.

On power-redundant systems, remove and replace only one power supply at a time in a system that is powered on.

1 Disconnect the power cable from the power source.

2 Disconnect the power cable from the power supply and remove the Velcro straps that bundle and secure the system cables.

NOTE:

You may have to unlatch and lift the optional cable management arm if it interferes with power-supply removal. For information about the cable management arm, see the system’s rack documentation.

3 Pull the power supply straight out to release it from the power distribution board and clear the chassis.

If you are permanently removing the power supply, you must install a

power supply blank to ensure proper system cooling. See "Installing the

Power Supply Blank" on page 157.

Installing System Components

155

book.book Page 156 Wednesday, January 20, 2010 10:20 AM

Figure 3-32.

Removing and Installing a Power Supply

1

2

3

156

1 power supply

3 cable retention bracket

2 locking tab

Installing a Power Supply

1 Verify that power supplies are the same type and have the same maximum output power.

NOTE:

The maximum output power (shown in watts) is listed on the power supply label.

2 If applicable, remove the power supply blank. See "Removing the Power

Supply Blank" on page 157.

3 Slide the new power supply into the chassis until the power supply is fully

seated and the release latch snaps into place. See Figure 3-32.

NOTE:

If you unlatched the cable management arm in step of the previous

procedure, relatch it. For information about the cable management arm, see the system’s rack documentation.

4 Connect the power cable to the power supply and plug the cable into a power outlet.

Installing System Components

book.book Page 157 Wednesday, January 20, 2010 10:20 AM

CAUTION:

When connecting the power cable, secure the cable with the Velcro strap.

NOTE:

When installing, hot-swapping, or hot-adding a new power supply in a system, allow several seconds for the system to recognize the power supply and determine its status. The power-supply status indicator turns green to signify that the power supply is functioning properly.

Removing the Power Supply Blank

If you are installing a power supply, remove the power supply blank by pulling outward on the blank.

CAUTION:

To ensure proper system cooling, the power supply blank must be installed in each power supply bay that does not have a power supply. Remove the power supply blank only if you are installing an additional power supply.

Installing the Power Supply Blank

NOTE:

Install the power supply blank only in power supply bays 2, 3, or 4.

To install the power supply blank, align the blank with the power supply bay and insert the blank into the chassis until it clicks into place.

System Battery

Replacing the System Battery

WARNING:

There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. See your safety information for additional information.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

Installing System Components

157

book.book Page 158 Wednesday, January 20, 2010 10:20 AM

Figure 3-33.

Replacing the System Battery

1

2

3

1 positive side of battery connector

3 negative side of battery connector

2 system battery

3 Locate the battery socket. See "System Board Connectors" on page 198.

CAUTION:

To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.

4 To remove the battery, support the battery connector by pressing down firmly on the positive side of the connector.

5 Press the battery toward the positive side of the connector and lift it up out of the securing tabs at the negative side of the connector.

6 To install a new system battery, support the battery connector by pressing down firmly on the positive side of the connector.

7 Hold the battery with the "+" facing up and slide it under the securing tabs at the positive side of the connector.

8 Press the battery straight down into the connector until it snaps into place.

9 Close the system. See "Closing the System" on page 90.

10 Reconnect the system to the electrical outlet and turn the system on, including any attached peripherals.

158

Installing System Components

book.book Page 159 Wednesday, January 20, 2010 10:20 AM

11 Enter the System Setup program to confirm that the battery is operating

properly. See "Using the System Setup Program and UEFI Boot Manager" on page 63.

12 Enter the correct time and date in the System Setup program's Time and

Date fields.

13 Exit the System Setup program.

SAS Backplane

NOTE:

Depending on your configuration, your system supports either an x16 SAS backplane or an x4 SAS backplane. The illustration in this section shows the removal and installation of an x16 SAS backplane.

Removing the SAS Backplane

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

CAUTION:

To prevent damage to the drives and backplane, you must remove the hard drives from the system before removing the backplane.

CAUTION:

You must note the number of each hard drive and temporarily label them before removal so that you can replace them in the same locations.

4 Remove all hard drives. See "Removing a Hard Drive" on page 109.

5 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

6 Remove the memory risers. See "Removing a Memory Riser" on page 100.

7 Disconnect the SAS data cable(s) and power cable from the backplane.

8 If applicable, disconnect the power/data cable from the optical drive.

Installing System Components

159

book.book Page 160 Wednesday, January 20, 2010 10:20 AM

9 Pull the blue release pin(s) and slide the backplane upwards.

10 Pull the backplane away from the front of the system until the securing slots are free from the tabs on the chassis.

Figure 3-34.

Removing and Installing a SAS Backplane

1 2

3

5

1 SAS backplane

3 release pins (2)

5 SAS cables (2)

4

160

Installing System Components

2 power cable

4 chassis tabs

book.book Page 161 Wednesday, January 20, 2010 10:20 AM

Installing the SAS Backplane

NOTE:

If you are installing an x16 SAS backplane, you must remove all the three chassis blanks from the system. If you are installing an x4 SAS backplane, you must ensure that all the three chassis blanks are installed in the system.

1 Align the slots on the SAS backplane with the tabs on the chassis.

2 Slide down the SAS backplane until the release pin snaps into place.

3 Connect the SAS data cable(s) and power cable to the backplane.

4 If applicable, connect the optical drive power/data cable.

5 Install the memory risers. See "Installing a Memory Riser" on page 101.

6 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

7 Install the hard drives in their original locations. See "Installing a Hard

Drive" on page 110.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

10 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

Power Distribution Board

Removing the Power Distribution Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2 Remove the power supplies from the system. See "Removing a Power

Supply" on page 155.

3 Open the system. See "Opening the System" on page 89.

Installing System Components

161

book.book Page 162 Wednesday, January 20, 2010 10:20 AM

4 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

5 Remove the memory risers. See "Removing a Memory Riser" on page 100.

6 Remove the cooling fan assembly. See "Removing the Cooling Fan

Assembly" on page 118.

7 Slide the board upwards and pull the board toward the front of the system until the tabs on the board are free from the securing slots on the chassis.

See Figure 3-35.

Figure 3-35.

Power Distribution Board

3

2

4

1

1 power distribution board connector 2 power distribution board

3 tabs (2) 4 securing slots (2)

162

Installing System Components

book.book Page 163 Wednesday, January 20, 2010 10:20 AM

Replacing the Power Distribution Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Unpack the new power distribution board assembly.

2 Align the tabs on the board with the slots on the chassis.

3 Press the board into the connector until it is fully seated.

4 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.

5 Install the memory risers. See "Installing a Memory Riser" on page 101.

6 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

7 Close the system. See "Closing the System" on page 90.

8 Install the power supplies in the system. See "Installing a Power Supply" on page 156.

9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Control Panel Assembly

Removing the Control Panel Display Module

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.

2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

Installing System Components

163

book.book Page 164 Wednesday, January 20, 2010 10:20 AM

3 Open the system. See "Opening the System" on page 89.

4 Disconnect the display module cable from the control panel board.

5 Using a knife or a small flat-blade screwdriver, insert the blade beneath the front panel of the display and slide the blade across the bottom to lift the

panel outward. See Figure 3-36.

6 Bend the panel upward to access to the mounting screws.

7 Using a T10 Torx driver, remove the two screws that secure the display module to the system chassis.

8 Remove the display module from the chassis cutout.

Installing the Control Panel Display Module

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Insert the display module into the chassis cutout and secure the module

with the two Torx screws. See Figure 3-36.

2 Attach the replacement panel to the front of the display module.

3 Connect the display module cable to the control panel board.

4 Close the system. See "Closing the System" on page 90.

5 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

6 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.

164

Installing System Components

book.book Page 165 Wednesday, January 20, 2010 10:20 AM

Figure 3-36.

Removing or Installing the Control Panel Assembly

1 2 3 4 5

1 T8 Torx screw

3 control panel board

5 control panel cable

7 display module

7

2 T10 Torx screws (3)

4 USB cable

6 display module cable

6

Installing System Components

165

book.book Page 166 Wednesday, January 20, 2010 10:20 AM

Removing the Control Panel Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

4 Remove the memory risers. See "Removing a Memory Riser" on page 100.

5 Remove the memory-riser guide. See "Removing the Memory-Riser Guide" on page 106.

6 Disconnect the cables connected to the control panel board.

NOTE:

Note the routing of the cables on the side on the system as you remove them from the control panel board. You must route these cables properly when you replace them to prevent them from being pinched or crimped.

7 Using a T10 Torx driver, remove the three screws that secure the control

panel board to the chassis. See Figure 3-36.

8 Using a T8 Torx driver, remove the screw that secures the control panel

board on the front of the system. See Figure 3-36.

9 Slide the control panel assembly toward the back of the system and take it out.

166

Installing System Components

book.book Page 167 Wednesday, January 20, 2010 10:20 AM

Installing the Control Panel Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Align the screw holes on the control panel board with the holes on the chassis.

2 Using a T10 Torx driver, replace the screws that secure the control panel

board to the chassis. See Figure 3-36.

3 Using a T8 Torx driver, replace the screw that secures the control panel

board on the front of the system. See Figure 3-36.

4 Connect all the cables to the control panel board.

5 Install the memory-riser guide. See "Installing the Memory-Riser Guide" on page 107.

6 Install the memory risers. See "Installing a Memory Riser" on page 101.

7 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

8 Close the system. See "Closing the System" on page 90.

9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing System Components

167

book.book Page 168 Wednesday, January 20, 2010 10:20 AM

168

System Board

Removing the System Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION:

If you are using the Trusted Program Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or system setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your hard drives.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 If applicable, remove the memory-riser blanks. See "Removing a Memory-

Riser Blank" on page 99.

4 Remove the memory risers. See "Removing a Memory Riser" on page 100.

5 Remove the cooling fan assembly. See "Removing the Cooling Fan

Assembly" on page 118.

6 Remove the power supply(s). See "Removing a Power Supply" on page 155.

7 Remove all expansion cards, the I/O card, and the integrated storage

controller card. See "Removing an Expansion Card" on page 128,

"Removing the I/O Card" on page 134, and "Removing the Integrated

Storage Controller Card" on page 143.

8 If applicable, remove the USB key from the system board. See "Internal

USB Memory Key" on page 120.

9 If applicable, remove the NIC hardware key from the system board. See

"Integrated NIC Hardware Key" on page 123.

10 Remove the processor(s). See "Removing a Processor" on page 148.

11 Remove the power distribution board. See "Removing the Power

Distribution Board" on page 161.

Installing System Components

book.book Page 169 Wednesday, January 20, 2010 10:20 AM

12 Disconnect all cables from the system board.

13 Loosen the thumbscrew that secures the system board to the chassis.

14 Pull the blue release pin and slide the system board toward the front of the system.

CAUTION:

Do not lift the system board assembly by grasping a memory module, processor, or other components.

15 Grasp the system board using the handle and the card guides. Angle the system board toward the front of the system and lift the board out of the chassis.

Figure 3-37.

Removing and Installing the System Board

5

4

1 system board

3 card guide

5 thumbscrew

3

2 handle

4 release pin

2

1

Installing System Components

169

book.book Page 170 Wednesday, January 20, 2010 10:20 AM

170

Installing the System Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Unpack the new system board.

2 Remove the labels from the processor shield and affix them to the system

identification panel on the front of the system. See Figure 3-37.

3 Using the handle and the card guide, lower the system board into the chassis.

CAUTION:

Do not lift the system board assembly by grasping a memory module, processor, or other components.

4 Slightly lift up the front of the system board and maneuver the system board to the bottom of the chassis until it lays completely flat.

5 Push the system board toward the back of the chassis until the board clicks into place.

6 Tighten the thumbscrew that secures the system board to the chassis.

7 Connect all the cables to the system board.

8 Install the power distribution board. See "Replacing the Power

Distribution Board" on page 163.

9 Transfer the processors to the new system board. See "Removing a

Processor" on page 148 and "Installing a Processor" on page 152.

10 If applicable, install the NIC hardware key on the system board. See

"Integrated NIC Hardware Key" on page 123.

11 If applicable, install the internal USB key on the system board. See

"Internal USB Memory Key" on page 120.

12 Install all expansion cards, the I/O card, and the integrated storage

controller card. See "Installing an Expansion Card" on page 126, "Installing

the I/O Card" on page 135, and "Installing the Integrated Storage

Controller Card" on page 145.

13 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.

Installing System Components

book.book Page 171 Wednesday, January 20, 2010 10:20 AM

14 Install the memory risers in the same locations on the new board. See

"Installing a Memory Riser" on page 101.

15 If applicable, install the memory-riser blanks. See "Installing a Memory-

Riser Blank" on page 100.

16 Close the system. See "Closing the System" on page 90.

17 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing System Components

171

book.book Page 172 Wednesday, January 20, 2010 10:20 AM

172

Installing System Components

book.book Page 173 Wednesday, January 20, 2010 10:20 AM

Troubleshooting Your System

Safety First—For You and Your System

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Troubleshooting System Startup Failure

If your system halts during startup prior to video imaging or LCD messaging, especially after installing an operating system or reconfiguring your system’s hardware, check for the following conditions:

• If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot Manager, the system will hang. The reverse is also true. You must boot to the same boot mode in which you installed the

operating system. See "Using the System Setup Program and UEFI Boot

Manager" on page 63.

• Invalid memory configurations could cause the system to halt at startup

without any video output. See "System Memory" on page 91.

For all other startup issues, note the LCD panel messages and any system

messages that appear onscreen. See "LCD Status Messages" on page 23 and

"System Messages" on page 41 for more information.

Troubleshooting External Connections

Ensure that all external cables are securely attached to the external connectors on your system before troubleshooting any external devices. See

Figure 1-1 and Figure 1-3 for the front- and back-panel connectors on your

system.

Troubleshooting Your System

173

book.book Page 174 Wednesday, January 20, 2010 10:20 AM

174

Troubleshooting the Video Subsystem

1 Check the system and power connections to the monitor.

2 Check the video interface cabling from the system to the monitor.

3 If two monitors are attached to the system, disconnect one monitor. The system supports only one monitor attached to either the front or rear video connector.

4 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.

If the tests run successfully, the problem is not related to video hardware.

If the tests fail, see "Getting Help" on page 203.

Troubleshooting a USB Device

1 Use the following steps to troubleshoot a USB keyboard and/or mouse. For other USB devices, go to step 2.

a Disconnect the keyboard and mouse cables from the system briefly and reconnect them. b Connect the keyboard/mouse to the USB port(s) on the opposite side of the system.

If the problem is resolved, restart the system, enter the System Setup program, and check if the nonfunctioning USB ports are enabled. c Replace the keyboard/mouse with another working keyboard/mouse.

If the problem is resolved, replace the faulty keyboard/mouse.

If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to the system.

2 Power down all attached USB devices and disconnect them from the system.

3 Restart the system and, if your keyboard is functioning, enter the system

setup program. Verify that all USB ports are enabled. See "Integrated

Devices Screen" on page 70.

If your keyboard is not functioning, you can also use remote access. If the

system is not accessible, see "Disabling a Forgotten Password" on page 201

Troubleshooting Your System

book.book Page 175 Wednesday, January 20, 2010 10:20 AM for instructions on setting the NVRAM_CLR jumper inside your system and restoring the BIOS to the default settings.

4 Reconnect and power on each USB device one at a time.

5 If a device causes the same problem, power down the device, replace the

USB cable, and power up the device.

If the problem persists, replace the device.

If all troubleshooting fails, see "Getting Help" on page 203.

Troubleshooting a Serial I/O Device

1 Turn off the system and any peripheral devices connected to the serial port.

2 Swap the serial interface cable with a working cable, and turn on the system and the serial device.

If the problem is resolved, replace the interface cable.

3 Turn off the system and the serial device, and swap the device with a comparable device.

4 Turn on the system and the serial device.

If the problem is resolved, replace the serial device.

If the problem persists, see "Getting Help" on page 203.

Troubleshooting a NIC

1 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.

2 Restart the system and check for any system messages pertaining to the

NIC controller.

3 Check the appropriate indicator on the NIC connector. See "NIC Indicator

Codes" on page 21.

• If the link indicator does not light, check all cable connections.

• If the activity indicator does not light, the network driver files might be damaged or missing.

Remove and reinstall the drivers if applicable. See the NIC's documentation.

Troubleshooting Your System

175

book.book Page 176 Wednesday, January 20, 2010 10:20 AM

176

• Change the autonegotiation setting, if possible.

• Use another connector on the switch or hub.

If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.

4 Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.

5 Enter the System Setup program and confirm that the NIC ports are

enabled. See "Integrated Devices Screen" on page 70.

6 Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and duplex. See the documentation for each network device.

7 Ensure that all network cables are of the proper type and do not exceed the maximum length.

If all troubleshooting fails, see "Getting Help" on page 203.

Troubleshooting a Wet System

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See"Opening the System" on page 89.

3 Disassemble components from the system. See "Installing System

Components" on page 85.

• Hard drives

• Optical drive

• Memory risers

• Cooling fan assembly

• SD cards

Troubleshooting Your System

book.book Page 177 Wednesday, January 20, 2010 10:20 AM

• USB memory key

• NIC hardware key

• Expansion cards and both expansion-card risers

• I/O card

• Integrated storage controller

• Power supplies

• Processors and heat sinks

4 Let the system dry thoroughly for at least 24 hours.

5 Reinstall the components you removed in step 3.

6 Close the system. See "Closing the System" on page 90.

7 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the system does not start properly, see "Getting Help" on page 203.

8 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.

If the tests fail, see "Getting Help" on page 203.

Troubleshooting a Damaged System

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

3 Ensure that the following components are properly installed:

• Hard drives

• Memory risers

• Cooling fan assembly

Troubleshooting Your System

177

book.book Page 178 Wednesday, January 20, 2010 10:20 AM

178

• SD cards

• USB memory key

• NIC hardware key

• Expansion cards and both expansion-card risers

• I/O card

• Integrated storage controller

• Power supplies

• Processors and heat sinks

4 Ensure that all cables are properly connected.

5 Close the system. See "Closing the System" on page 90.

6 Run the system board tests in the system diagnostics. See "Running the

Embedded System Diagnostics" on page 194.

If the tests fail, see "Getting Help" on page 203.

Troubleshooting the System Battery

NOTE:

If the system is turned off for long periods of time (for weeks or months), the

NVRAM may lose its system configuration information. This situation is caused by a defective battery.

1 Re-enter the time and date through the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on page 63.

2 Turn off the system and disconnect it from the electrical outlet for at least one hour.

3 Reconnect the system to the electrical outlet and turn on the system.

4 Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace

the battery. See "Replacing the System Battery" on page 157.

NOTE:

Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.

If the problem is not resolved by replacing the battery, see "Getting Help" on page 203.

Troubleshooting Your System

book.book Page 179 Wednesday, January 20, 2010 10:20 AM

Troubleshooting Power Supplies

CAUTION:

At least one power supply must be installed for the system to operate.

Operating the system with only one power supply installed for extended periods of time can cause the system to overheat.

1 Identify the faulty power supply by the power supply's fault indicator. See

"Power Indicator Codes" on page 22.

CAUTION:

If troubleshooting a power supply mismatch error, replace only the power supply with the flashing indicator. Swapping the opposite power supply to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to an Energy Smart configuration or vice versa, you must power down the system.

2 Reseat the power supply by removing and reinstalling it. See "Removing a

Power Supply" on page 155 and "Installing a Power Supply" on page 156.

NOTE:

After installing a power supply, allow several seconds for the system to recognize the power supply and to determine if it is working properly. The power indicator turns green to signify that the power supply is functioning properly.

If the problem persists, replace the faulty power supply.

3 If the problem persists, see "Getting Help" on page 203.

Troubleshooting Your System

179

book.book Page 180 Wednesday, January 20, 2010 10:20 AM

Troubleshooting System Cooling Problems

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Ensure that none of the following conditions exist:

• System cover, drive blank, memory-module blank, power-supply blank, or back filler bracket is removed.

• Ambient temperature is too high. See your Getting Started Guide for your system’s operating temperature requirements.

• External airflow is obstructed.

• Cables inside the system obstruct airflow.

An individual cooling fan is removed or has failed. See"Troubleshooting a

Fan" on page 180.

• The expansion card installation guidelines have not been followed. See

"Expansion Card Installation Guidelines" on page 124.

Troubleshooting a Fan

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Open the system. See "Opening the System" on page 89.

CAUTION:

The cooling fans are hot-swappable. To maintain proper cooling while the system is on, only replace one fan at a time.

2 Locate the faulty fan indicated by the LCD panel or the diagnostic software

180

Troubleshooting Your System

book.book Page 181 Wednesday, January 20, 2010 10:20 AM

3 Remove and reseat the fan. See "Removing a Cooling Fan" on page 116

and "Installing a Cooling Fan" on page 117.

NOTE:

Wait at least 30 seconds for the system to recognize the fan and determine whether it is working properly.

4 If the problem is not resolved, install a new fan. See "Removing a Cooling

Fan" on page 116 and "Installing a Cooling Fan" on page 117.

If the replacement fan is working properly, close the system. See "Closing the System" on page 90.

If the replacement fan does not operate, see "Getting Help" on page 203.

Troubleshooting System Memory

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

Invalid memory configurations can cause your system to halt at startup

without video output. See "General Memory Module Installation Guidelines" on page 92 and verify that your memory configuration complies with all applicable

guidelines.

1 If the system is operational, run the appropriate online diagnostic test. See

"Using Online Diagnostics" on page 193.

If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.

2 If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at least 10 seconds and then reconnect the system to power.

3 Turn on the system and attached peripherals and note the messages on the screen.

Go to step 14 if an error message appears indicating a fault with a specific memory module.

Troubleshooting Your System

181

book.book Page 182 Wednesday, January 20, 2010 10:20 AM

4 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 67. Make any changes to the

memory settings, if needed.

If the memory settings match the installed memory but a problem is still indicated, go to step 14.

5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

6 Open the system. See "Opening the System" on page 89.

7 Remove the memory risers. See "Removing a Memory Riser" on page 100.

8 Check the memory channels and ensure that they are populated correctly.

See "General Memory Module Installation Guidelines" on page 92.

9 Reseat the memory modules in their sockets. See "Installing Memory

Modules" on page 102.

10 Install the memory risers. See "Installing a Memory Riser" on page 101.

11 Close the system. See "Closing the System" on page 90.

12 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

13 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 67.

If the problem is not resolved, proceed with the next step.

14 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module.

15 Open the system. See "Opening the System" on page 89.

16 Remove the memory risers. See "Removing a Memory Riser" on page 100.

17 To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a module of the same type

and capacity. See "Installing Memory Modules" on page 102.

18 Install the memory risers. See "Installing a Memory Riser" on page 101.

19 Close the system. See "Closing the System" on page 90.

20 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

182

Troubleshooting Your System

book.book Page 183 Wednesday, January 20, 2010 10:20 AM

21 As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system.

22 If the memory problem is still indicated, repeat step 14 through step 19 for

each memory module installed.

If the problem persists after all memory modules have been checked, see

"Getting Help" on page 203.

Troubleshooting an Internal USB Key

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Enter the System Setup program and ensure that the internal USB key

port is enabled. See "Integrated Devices Screen" on page 70.

2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 Locate the USB key and reseat it. See "Internal USB Memory Key" on page 120.

5 Close the system. See "Closing the System" on page 90.

6 Turn on the system and attached peripherals and check if the USB key is functioning.

7 If the problem is not resolved, repeat step 2 and step 3.

8 Insert a different USB key that you know works properly.

9 Close the system. See "Closing the System" on page 90.

10 Turn on the system and attached peripherals and check if the USB key is functioning.

If the problem is not resolved, see "Getting Help" on page 203.

Troubleshooting Your System

183

book.book Page 184 Wednesday, January 20, 2010 10:20 AM

184

Troubleshooting an Internal SD Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Enter the System Setup program and ensure that the internal SD card port

is enabled. See "Integrated Devices Screen" on page 70.

2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 Reseat the SD module cable. See "Installing the Internal Dual SD Module" on page 141.

CAUTION:

If the Redundancy option is set to Mirror Mode in the Integrated

Devices screen of the system setup, you must follow the instructions in step 5 to step 9 to avoid loss of data. If the Redundancy option is set to Disabled, proceed to step 10.

NOTE:

When an SD card failure occurs, the internal dual SD module controller notifies the system. On the next reboot, the system prompts you with a message indicating the failure.

5 If SD card 1 has failed, remove the card from the SD1 slot. See "Removing an Internal SD Card" on page 142. If SD card 2 has failed, install a new SD

card and proceed to step 8.

6 Insert the card present in the SD2 slot into the SD1 slot. See "Removing an Internal SD Card" on page 142 and "Installing an Internal SD Card" on page 142.

7 Insert the new SD card into the SD2 slot.

8 Close the system. See "Closing the System" on page 90.

9 Turn on the system and attached peripherals and check if the SD card is functioning.

If the problem is not resolved, see "Getting Help" on page 203.

10 Insert a different SD card that you know works properly.

Troubleshooting Your System

book.book Page 185 Wednesday, January 20, 2010 10:20 AM

11 Close the system. See "Closing the System" on page 90.

12 Turn on the system and attached peripherals and check if the SD card is functioning.

If the problem is not resolved, see "Getting Help" on page 203.

Troubleshooting an Optical Drive

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 If applicable, remove the bezel. See "Removing the Front Bezel" on page 87.

2 Try using a different CD or DVD.

3 Enter the System Setup program and ensure that the integrated SATA

controller and the drive's SATA port are enabled. See "Using the System

Setup Program and UEFI Boot Manager" on page 63.

4 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.

5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

6 Open the system. See "Opening the System" on page 89.

7 Ensure that the interface cable is securely connected to the optical drive

and to the system board. See "Optical Drive" on page 113.

8 Ensure that a power cable is properly connected to the drive.

9 Close the system. See "Closing the System" on page 90.

10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem is not resolved, see "Getting Help" on page 203.

Troubleshooting Your System

185

book.book Page 186 Wednesday, January 20, 2010 10:20 AM

186

Troubleshooting a Tape Backup Unit

1 Ensure that the tape drive is turned on.

2 Try using a different tape cartridge.

3 Ensure that the device drivers for the tape drive are installed and are configured correctly. See your tape drive documentation for more information about device drivers.

4 Ensure that the tape drive’s interface cable is fully connected to the external port on the controller card.

5 For SCSI tape drives, verify that the tape drive is configured for a unique

SCSI ID number and that the tape drive is terminated or not terminated, based on the interface cable used to connect the drive. See the documentation for the tape drive for instructions on selecting the SCSI ID number and enabling or disabling termination.

6 Run the appropriate online diagnostics tests. See "Using Online

Diagnostics" on page 193.

If you cannot resolve the problem, see "Getting Help" on page 203.

7 Reinstall the tape-backup software as instructed in the tape-backup software documentation. See your tape documentation for information about reinstalling the software and troubleshooting the tape drive.

Troubleshooting a Hard Drive

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION:

This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

1 Run the appropriate online diagnostics test. See "Using Online

Diagnostics" on page 193.

Depending on the results of the diagnostics test, proceed as needed through the following steps.

Troubleshooting Your System

book.book Page 187 Wednesday, January 20, 2010 10:20 AM

2 If applicable, remove the bezel. See "Removing the Front Bezel" on page 87.

3 If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following steps.

a Restart the system and enter the host adapter configuration utility program by pressing <Ctrl><R> for a PERC controller or

<Ctrl><C> for a SAS controller.

See the documentation supplied with the host adapter for information about the configuration utility.

b c

Ensure that the hard drive(s) have been configured correctly for the

RAID array.

Take the hard drive offline and reseat the drive. See "Removing a Hard

Drive" on page 109.

d Exit the configuration utility and allow the system to boot to the operating system.

4 Ensure that the required device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information.

5 Restart the system, enter the System Setup program, and verify that the controller is enabled and the drives appear in the System Setup program.

See "Using the System Setup Program and UEFI Boot Manager" on page 63.

If the problem persists, see "Troubleshooting a Storage Controller" on page 187.

Troubleshooting a Storage Controller

NOTE:

When troubleshooting a SAS or PERC controller, also see the documentation for your operating system and the controller.

1 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.

2 Enter the System Setup program and ensure that the SAS or PERC

controller is enabled. See "Using the System Setup Program and UEFI

Boot Manager" on page 63.

Troubleshooting Your System

187

book.book Page 188 Wednesday, January 20, 2010 10:20 AM

3 Restart the system and press the applicable key sequence to enter the configuration utility program:

• <Ctrl><C> for a SAS controller

• <Ctrl><R> for PERC controller

See the controller's documentation for information about configuration settings.

4 Check the configuration settings, make any necessary corrections, and restart the system.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

5 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

6 Open the system. See "Opening the System" on page 89.

7 Ensure that the controller card is firmly seated into the system board

connector. See "Integrated Storage Controller Card" on page 143.

8 If you have a PERC controller with a battery-backed cache, ensure that the

RAID battery is properly connected and, if applicable, the memory module on the PERC card is properly seated.

9 Verify that the cable connections between the SAS backplane and the

integrated storage controller are correct. See "Installing the Integrated

Storage Controller Card" on page 145 and Figure 6-2.

Ensure that the cables are firmly connected to the storage controller and the SAS backplane board.

10 Close the system. See "Closing the System" on page 90.

11 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help" on page 203.

188

Troubleshooting Your System

book.book Page 189 Wednesday, January 20, 2010 10:20 AM

Troubleshooting Expansion Cards

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.

1 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.

2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 Verify that the installed expansion cards are compliant with the expansion

card installation guidelines. See "Expansion Card Installation Guidelines" on page 124.

5 Ensure that each expansion card is firmly seated in its connector. See

"Installing an Expansion Card" on page 126.

6 Close the system. See "Closing the System" on page 90.

7 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

8 If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

9 Open the system. See "Opening the System" on page 89.

10 Remove all expansion cards installed in the system. See "Removing an

Expansion Card" on page 128.

11 Close the system. See "Closing the System" on page 90.

12 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

13 Run the appropriate online diagnostic test.

If the tests fail, see "Getting Help" on page 203.

Troubleshooting Your System

189

book.book Page 190 Wednesday, January 20, 2010 10:20 AM

190

14 For each expansion card you removed in step 10, perform the following steps: a Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

b c d e

Open the system. See "Opening the System" on page 89.

Reinstall one of the expansion cards.

Close the system. See "Closing the System" on page 90.

Run the appropriate diagnostic test.

If the tests fail, see "Getting Help" on page 203.

Troubleshooting the Processors

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Run the appropriate online diagnostics test. See "Using Online

Diagnostics" on page 193.

2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3 Open the system. See "Opening the System" on page 89.

4 Remove the memory risers. See "Removing a Memory Riser" on page 100.

5 Remove the cooling fan assembly. See "Removing the Cooling Fan

Assembly" on page 118.

6 Ensure that each processor and heat sink are properly installed. See

"Removing a Processor" on page 148.

7 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.

8 Install the memory risers. See "Installing a Memory Riser" on page 101.

9 Close the system. See "Closing the System" on page 90.

10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

Troubleshooting Your System

book.book Page 191 Wednesday, January 20, 2010 10:20 AM

11 Run the appropriate online diagnostic test.

If the problem still persists, see step 12.

12 Open the system. See "Opening the System" on page 89.

13 Remove the memory risers. See "Removing a Memory Riser" on page 100.

14 Remove the cooling fan assembly. See "Removing the Cooling Fan

Assembly" on page 118.

15 If your system has four processors, remove all processors except for

processor 1 and processor 2. See "Installing a Processor" on page 152.

16 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.

17 Install the memory risers. See "Installing a Memory Riser" on page 101.

18 Close the system. See "Closing the System" on page 90.

19 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

20 Run the appropriate online diagnostic test.

If the test fails, the processor is faulty. See "Getting Help" on page 203.

If the test passes, replace processor 1 and 2 with processor 3 and processor

4. Run the appropriate online diagnostic test. If the test fails, the processor

is faulty. See "Getting Help" on page 203.

Troubleshooting Your System

191

book.book Page 192 Wednesday, January 20, 2010 10:20 AM

192

Troubleshooting Your System

book.book Page 193 Wednesday, January 20, 2010 10:20 AM

Running the System Diagnostics

If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your system's hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use diagnostics test results to help you solve the problem.

Using Online Diagnostics

To assess a system problem, first use the online diagnostics. Online

Diagnostics is a suite of diagnostic programs, or test modules, that include diagnostic tests on chassis and storage components such as hard drives, physical memory, communications, NICs, CMOS, and more. If you are unable to identify the problem using the online diagnostics, then use the embedded system diagnostics.

The files required to run the online diagnostics for systems running supported

Microsoft

®

Windows

®

and Linux operating systems are available at support.dell.com and on the CDs that came with your system. For information about using diagnostics, see the Dell Online Diagnostics User's

Guide.

Embedded System Diagnostics Features

The system diagnostics provides a series of menus and options for particular device groups or devices. The system diagnostics menus and options allow you to:

• Run tests individually or collectively

• Control the sequence of tests

• Repeat tests

• Display, print, or save test results

• Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is reached

• View help messages that briefly describe each test and its parameters

Running the System Diagnostics

193

book.book Page 194 Wednesday, January 20, 2010 10:20 AM

• View status messages that inform you if tests are completed successfully

• View error messages that inform you of problems encountered during testing

When to Use the Embedded System Diagnostics

If a major component or device in the system does not operate properly, component failure may be indicated. As long as the processor and the system's input/output devices are functioning, you can use the embedded system diagnostics to help identify the problem.

Running the Embedded System Diagnostics

The embedded system diagnostics program is run from the Lifecycle

Controller screen.

CAUTION:

Use the embedded system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages.

1 As the system boots, press <F10>.

2 Click Diagnostics in the left pane and click Launch Diagnostics in the right pane.

The Diagnostics menu allows you to run all or specific diagnostics tests or to exit.

System Diagnostics Testing Options

Click the testing option in the Main Menu window.

Testing Option

Express Test

Extended Test

Custom Test

Information

Function

Performs a quick check of the system. This option runs device tests that do not require user interaction.

Performs a more thorough check of the system. This test can take an hour or longer.

Tests a particular device.

Displays test results.

194

Running the System Diagnostics

book.book Page 195 Wednesday, January 20, 2010 10:20 AM

Using the Custom Test Options

When you select Custom Test in the Main Menu window, the Customize window allows you to select the device(s) to be tested, select specific options for testing, and view the test results.

Selecting Devices for Testing

The left side of the Customize window lists devices that can be tested. Click the (+) next to a device or module to view its components. Click (+) on any component to view the tests that are available. Clicking a device, rather than its components, selects all of the components of the device for testing.

NOTE:

After you select all the devices and components that you want to test, highlight All Devices and then click Run Tests.

Selecting Diagnostics Options

From the Diagnostics Options area, select the test(s) you want to run on a device.

• Non-Interactive Tests Only — Runs only tests that require no user intervention.

• Quick Tests Only — Runs only the quick tests on the device.

• Show Ending Timestamp — Time stamps the test log.

• Test Iterations — Selects the number of times the test is run.

• Log output file pathname — Enables you to specify the diskette drive or

USB memory key where the test log file is saved. You cannot save the file to a hard drive.

Running the System Diagnostics

195

book.book Page 196 Wednesday, January 20, 2010 10:20 AM

Viewing Information and Results

The following tabs in the Customize window provide information about the test and the test results.

• Results — Displays the test that ran and the result.

• Errors — Displays any errors that occurred during the test.

• Help — Displays information about the currently selected device, component, or test.

• Configuration — Displays basic configuration information about the currently selected device.

• Parameters — Displays parameters that you can set for the test.

196

Running the System Diagnostics

book.book Page 197 Wednesday, January 20, 2010 10:20 AM

Jumpers and Connectors

System Board Jumper

For information on resetting the password jumper to disable a password, see

"Disabling a Forgotten Password" on page 201.

Table 6-1.

System Board Jumper Settings

Jumper

PWRD_EN

Setting Description

(default) The password feature is enabled (pins 2-4)

NVRAM_CLR

The password feature is disabled, and iDRAC6 local access is unlocked at the next AC power cycle (pins 4-6)

(default) The configuration settings are retained at system boot (pins 3-5)

The configuration settings are cleared at the next system boot (pins 1-3)

Jumpers and Connectors

197

book.book Page 198 Wednesday, January 20, 2010 10:20 AM

7

6

5

4

3

2

1

System Board Connectors

Figure 6-1.

System Board Connectors

10 11

9

8

32 31 30 29 28 27 26 25 24 23

16

17

18

19

20

21

22

12

13

14

15

198

Jumpers and Connectors

book.book Page 199 Wednesday, January 20, 2010 10:20 AM

Table 6-2.

System Board Jumpers and Connectors

16

17

18

19

12

13

14

15

20

21

Item Connector

7

8

5

6

3

4

1

2

9

10

11

CTRL_PNL

CTRL_USB

SATA_A

J_CPU4

J_CPU2

FAN1

J_PDB_MISC

FAN4

INT_USB

SLOT 1

SLOT2

SLOT3

SLOT4

SLOT5

SLOT6

PWRD_EN

NVRAM_CLR

SLOT7

IO_RISER

INT_STORAGE

J_SLOT7PWR

FAN5

ISCSI_KEY

FAN2

FAN6

FAN3

J_CPU3

Description

Control panel interface connector

Control panel USB interface connector

SATA A connector

Processor 4

Processor 2

System cooling fan 1

Power distribution board connector

System cooling fan 4

Internal USB connector

PCIE_G2_X4

PCIE_G2_X8

PCIE_G2_X8

PCIE_G2_X8

PCIE_G2_X4

PCIE_G2_X4

Password enable jumper

NVRAM clear jumper

PCIE_G2_X16

I/O card connector

Internal storage controller card connector

Power connector

System cooling fan 5

NIC hardware key

System cooling fan 2

System cooling fan 6

System cooling fan 3

Processor 3

Jumpers and Connectors

199

book.book Page 200 Wednesday, January 20, 2010 10:20 AM

Table 6-2.

System Board Jumpers and Connectors

Item Connector

26

27

28

29

22

23

24

25

30

31

32

J_CPU1

MEM_RISER_A

MEM_RISER_B

MEM_RISER_E

MEM_RISER_F

MEM_RISER_C

MEM_RISER_D

MEM_RISER_G

BP_PWR/MISC

MEM_RISER_H

SATA_PWR

Description

Processor 1

Memory riser A connector

Memory riser B connector

Memory riser E connector

Memory riser F connector

Memory riser C connector

Memory riser D connector

Memory riser G connector

Power connector

Memory riser H connector

SATA power connector

SAS Backplane Board Connectors

Figure 6-2.

x16 SAS Backplane Board Connector

4

5

6

1

2 3

200

Jumpers and Connectors

book.book Page 201 Wednesday, January 20, 2010 10:20 AM

1 hard-drive connectors 0–3

3 hard-drive connectors 8–11

5 SAS connectors (2)

Figure 6-3.

x4 SAS Backplane Board Connector

2 hard-drive connectors 4–7

4 power connector

6 hard-drive connectors 12–15

1

3

2

1 power connector

3 SAS connector

2 hard-drive connectors 0–3

Disabling a Forgotten Password

The system's software security features include a system password and a setup

password, which are discussed in detail in "Using the System Setup Program and UEFI Boot Manager" on page 63. The password jumper enables these

password features or disables them and clears any password(s) currently in use.

CAUTION:

See "Protecting Against Electrostatic Discharge" in the safety instructions that came with the system.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2 Open the system. See "Opening the System" on page 89.

Jumpers and Connectors

201

book.book Page 202 Wednesday, January 20, 2010 10:20 AM

3 Remove the jumper plug from the password jumper.

See Figure 6-1 to locate the password jumper (labeled "PWRD_EN") on the system board.

4 Close the system.

5 Reconnect your system and peripherals to their electrical outlets, and turn on the system.

The existing passwords are not disabled (erased) until the system boots with the password jumper plug removed. However, before you assign a new system and/or setup password, you must install the jumper plug.

NOTE:

If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next time it boots.

6 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

7 Open the system. See "Closing the System" on page 90.

8 Install the jumper plug on the password jumper.

9 Lower the memory module shroud.

10 Close the system.

11 Reconnect your system and peripherals to their electrical outlets, and turn on the system.

12 Assign a new system and/or setup password.

To assign a new password using the System Setup program, see "Assigning a System Password" on page 79.

202

Jumpers and Connectors

book.book Page 203 Wednesday, January 20, 2010 10:20 AM

Getting Help

Contacting Dell

For customers in the United States, call 800-WWW-DELL (800-999-3355).

NOTE:

If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog.

Dell provides several online and telephone-based support and service options.

Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:

1 Visit support.dell.com.

2 Verify your country or region in the Choose A Country/Region drop-down menu at the bottom of the page.

3 Click Contact Us on the left side of the page.

4 Select the appropriate service or support link based on your need.

5 Choose the method of contacting Dell that is convenient for you.

Getting Help

203

book.book Page 204 Wednesday, January 20, 2010 10:20 AM

204

Getting Help

book.book Page 205 Wednesday, January 20, 2010 10:20 AM

Index

B batteries

troubleshooting, 178

battery

troubleshooting the RAID card battery, 187

battery (system)

replacing, 157

blank

hard drive, 108

power supply, 157

C cabling

optical drive, 113

CD drive

troubleshooting, 185

CD/DVD drive

See optical drive.

connectors

USB, 12, 19 video, 12, 19

contacting Dell, 203

control panel assembly

features, 12

LCD panel features, 14

cooling fans

troubleshooting, 180

D damaged systems

troubleshooting, 177

Dell

contacting, 203

Dell PowerEdge Diagnostics

using, 193

diagnostics

advanced testing options, 193 testing options, 193 using Dell PowerEdge

Diagnostics, 193

DIMMs

See memory modules (DIMMs).

drive blank

installing, 108 removing, 108

drive carrier

hard drive, 112

E

error messages, 64

expansion card

troubleshooting, 189

Index

205

book.book Page 206 Wednesday, January 20, 2010 10:20 AM expansion cards

installing, 126

removing, 128, 134

SAS controller, 143

expansion slots, 124

F front bezel

installing, 87 removing, 87

front-panel features, 12

G guidelines

connecting external devices, 21

expansion card installation, 124

memory installation, 92

H hard drive

drive carrier, 112

installing, 110

removing, 109

troubleshooting, 186

heat sink, 150

hot-swap

hard drives, 107

I iDRAC card

installing, 136

iDRAC Configuration Utility, 83

indicators

front-panel, 12

NIC, 21

power, 12, 22

installing

expansion card, 126

front bezel, 87

hard drive blank, 108

hard drives, 110

iDRAC card, 136

memory modules, 102

optical drive, 113

power supply blank, 157

SAS backplane board, 161

SAS controller, 145

K keyboards

troubleshooting, 174

L

LCD panel

features, 14

menus, 15

Index

206

book.book Page 207 Wednesday, January 20, 2010 10:20 AM

M memory

troubleshooting, 181

memory key connector

(USB), 120

Memory Mirroring memory mode, 92

memory mode

memory mirroring, 92

memory modules (DIMMs)

configuring, 92

installing, 102

RDIMM configurations, 93

removing, 105

UDIMM configurations, 125

memory riser, 100

installing, 101

removing, 100

memory-riser blank, 99

installing, 100

removing, 99

messages

error messages, 64

status LCD, 23

system, 41

warning, 60

N

NIC

indicators, 21

NIC TOE, 123

NICs

troubleshooting, 175

O optical drive

installing, 113

options

system setup, 65

P password

disabling, 201

setup, 81

system, 79

phone numbers, 203

POST

accessing system features, 11

power indicators, 12, 22

power supplies

indicators, 22

removing, 155

replacing, 156

troubleshooting, 179

power supply blank, 157

processors

troubleshooting, 190

R

recommended tools, 85

Index

207

book.book Page 208 Wednesday, January 20, 2010 10:20 AM removing

expansion card, 128, 134

front bezel, 87

hard drive blank, 108

hard drive from a drive carrier, 112

hard drives, 109

memory modules, 105

power supply, 155

power supply blank, 157

SAS backplane board, 159

SAS controller, 143

system board, 168

replacing

power supply, 156

system battery, 157

S

safety, 173

SAS backplane board

installing, 161

removing, 159

SAS controller card

installing, 145

removing, 143

SAS controller daughter card

troubleshooting, 187

SAS RAID controller daughter card

troubleshooting, 187

SD card

troubleshooting, 183

securing your system, 74, 80

service-only procedure

system board, 168

setup password, 81

slots

See expansion slots.

startup

accessing system features, 11

support

contacting Dell, 203

system board

installing, 170

removing, 168

system cooling

troubleshooting, 180

system features

accessing, 11

system messages, 41

system password, 79

system setup

options, 65

system setup program

boot settings, 69

embedded server management options, 73

entering, 64

integrated devices options, 70

keystroke, 64

memory settings, 67

PCI IRQ assignments, 71

power management options, 73

processor settings, 68

SATA settings, 69

Index

208

book.book Page 209 Wednesday, January 20, 2010 10:20 AM

serial communications options, 72

system security options, 74

system setup screens

main, 65

system startup failure, 173

T

telephone numbers, 203

TPM security, 74

troubleshooting

battery, 178

CD drive, 185

cooling fans, 180

damaged system, 177

expansion card, 189

external connections, 173

hard drive, 186

internal USB key, 183

keyboard, 174

memory, 181

NIC, 175

power supplies, 179

SAS RAID controller daughter card, 187

SD card, 183

system cooling, 180

system startup failure, 173

video, 174

wet system, 176

U

UEFI Boot Manager

entering, 76

main screen, 77

System Utilities screen, 78

UEFI Boot Settings screen, 77

USB

front-panel connectors, 12

internal connector for memory key, 120

USB key

troubleshooting, 183

V video

front-panel connectors, 12

troubleshooting, 174

W

warning messages, 60 warranty, 60

wet system

troubleshooting, 176

Index

209

book.book Page 210 Wednesday, January 20, 2010 10:20 AM

Index

210

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!