Dell™ PowerEdge™ R910
Hardware Owner’s
Manual
Regulatory Model: E06S Series
Regulatory Type: E06S001
book.book Page 2 Wednesday, January 20, 2010 10:20 AM
Notes, Cautions, and Warnings
NOTE:
A NOTE indicates important information that helps you make better use of your computer.
CAUTION:
A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.
WARNING:
A WARNING indicates a potential for property damage, personal injury, or death.
____________________
Information in this document is subject to change without notice.
© 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.
Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Regulatory Model: E06S Series
Regulatory Type: E06S001
January 2010 Rev. A00
book.book Page 3 Wednesday, January 20, 2010 10:20 AM
Contents
1
About Your System . . . . . . . . . . . . . . . . . .
11
Accessing System Features During Startup . . . . . . .
11
Front-Panel Features and Indicators . . . . . . . . . .
12
LCD Panel Features . . . . . . . . . . . . . . . . . . .
14
Home Screen . . . . . . . . . . . . . . . . . . . .
15
Setup Menu . . . . . . . . . . . . . . . . . . . . .
16
View Menu . . . . . . . . . . . . . . . . . . . . .
17
Hard-Drive Indicator Patterns . . . . . . . . . . . . . .
18
Back-Panel Features and Indicators . . . . . . . . . .
19
Guidelines for Connecting External Devices . . . . . .
21
NIC Indicator Codes . . . . . . . . . . . . . . . . . . .
21
Power Indicator Codes . . . . . . . . . . . . . . . . .
22
LCD Status Messages . . . . . . . . . . . . . . . . . .
23
Viewing Status Messages . . . . . . . . . . . . .
23
Removing LCD Status Messages . . . . . . . . . .
24
System Messages . . . . . . . . . . . . . . . . . . . .
41
Warning Messages . . . . . . . . . . . . . . . . . . .
60
Diagnostics Messages . . . . . . . . . . . . . . . . .
60
Alert Messages . . . . . . . . . . . . . . . . . . . . .
60
Contents
3
book.book Page 4 Wednesday, January 20, 2010 10:20 AM
4
Other Information You May Need . . . . . . . . . . . .
60
2
Using the System Setup Program and
. . . . . . . . . . . . . . . . . 63
Choosing the System Boot Mode . . . . . . . . . . . .
63
Entering the System Setup Program . . . . . . . . . . .
64
Responding to Error Messages . . . . . . . . . . .
64
Using the System Setup Program Navigation
Keys . . . . . . . . . . . . . . . . . . . . . . . . .
64
System Setup Options . . . . . . . . . . . . . . . . . .
65
Main Screen . . . . . . . . . . . . . . . . . . . .
65
Memory Settings Screen . . . . . . . . . . . . . .
67
Processor Settings Screen . . . . . . . . . . . . .
68
SATA Settings Screen . . . . . . . . . . . . . . . .
69
Boot Settings Screen . . . . . . . . . . . . . . . .
69
Integrated Devices Screen . . . . . . . . . . . . .
70
PCI IRQ Assignments Screen . . . . . . . . . . . .
71
Serial Communication Screen . . . . . . . . . . .
72
Embedded Server Management Screen . . . . . .
73
Power Management Screen . . . . . . . . . . . .
73
System Security Screen . . . . . . . . . . . . . .
74
Exit Screen . . . . . . . . . . . . . . . . . . . . .
76
Entering the UEFI Boot Manager . . . . . . . . . . . . .
76
Using the UEFI Boot Manager Navigation Keys . .
77
UEFI Boot Manager Screen . . . . . . . . . . . . .
77
UEFI Boot Settings Screen . . . . . . . . . . . . .
78
System Utilities Screen . . . . . . . . . . . . . . .
78
System and Setup Password Features . . . . . . . . . .
79
Using the System Password . . . . . . . . . . . .
79
Using the Setup Password . . . . . . . . . . . . .
81
Contents
book.book Page 5 Wednesday, January 20, 2010 10:20 AM
Embedded System Management . . . . . . . . . . . .
82
iDRAC Configuration Utility . . . . . . . . . . . . . . .
83
Entering the iDRAC Configuration Utility . . . . . .
83
3
Installing System Components . . . . . . . .
85
Recommended Tools . . . . . . . . . . . . . . . . . . .
85
Inside the System . . . . . . . . . . . . . . . . . . . .
85
Front Bezel (Optional) . . . . . . . . . . . . . . . . . .
87
Removing the Front Bezel . . . . . . . . . . . . .
87
Installing the Front Bezel . . . . . . . . . . . . . .
87
System Identification Panel . . . . . . . . . . . . . . .
88
Removing the System Identification Panel . . . . .
88
Installing the System Identification Panel . . . . .
89
Opening and Closing the System . . . . . . . . . . . .
89
Opening the System . . . . . . . . . . . . . . . .
89
Closing the System . . . . . . . . . . . . . . . . .
90
System Memory . . . . . . . . . . . . . . . . . . . . .
91
General Memory Module Installation
Guidelines . . . . . . . . . . . . . . . . . . . . . .
92
Removing a Memory-Riser Blank . . . . . . . . .
99
Installing a Memory-Riser Blank . . . . . . . . . .
100
Removing a Memory Riser . . . . . . . . . . . . .
100
Installing a Memory Riser . . . . . . . . . . . . .
101
Installing Memory Modules . . . . . . . . . . . .
102
Removing Memory Modules . . . . . . . . . . . .
105
Removing the Memory-Riser Guide . . . . . . . .
106
Installing the Memory-Riser Guide . . . . . . . . .
107
Contents
5
book.book Page 6 Wednesday, January 20, 2010 10:20 AM
6
Contents
Hard Drives . . . . . . . . . . . . . . . . . . . . . . .
107
Removing a Hard-Drive Blank . . . . . . . . . .
108
Installing a Hard-Drive Blank . . . . . . . . . . .
108
Removing a Hard Drive . . . . . . . . . . . . . .
109
Installing a Hard Drive . . . . . . . . . . . . . .
110
Removing a Hard Drive From a Hard-Drive
Carrier . . . . . . . . . . . . . . . . . . . . . . .
112
Installing a Hard Drive Into a Drive Carrier . . . .
113
Optical Drive . . . . . . . . . . . . . . . . . . . . . .
113
Removing an Optical Drive . . . . . . . . . . . .
113
Installing an Optical Drive . . . . . . . . . . . .
115
Cooling Fans . . . . . . . . . . . . . . . . . . . . . .
116
Removing a Cooling Fan . . . . . . . . . . . . .
116
Installing a Cooling Fan . . . . . . . . . . . . . .
117
Removing the Cooling Fan Assembly . . . . . . .
118
Installing the Cooling Fan Assembly . . . . . . .
120
Internal USB Memory Key . . . . . . . . . . . . . . .
120
Integrated NIC Hardware Key . . . . . . . . . . . . .
123
Expansion Cards and Expansion-Card Riser . . . . .
124
Expansion Card Installation Guidelines . . . . . .
124
Installing an Expansion Card . . . . . . . . . . .
126
Removing an Expansion Card . . . . . . . . . . .
128
Installing an Expansion-Card Riser . . . . . . . .
129
Removing an Expansion-Card Riser . . . . . . .
133
I/O Card . . . . . . . . . . . . . . . . . . . . . . . . .
134
Removing the I/O Card . . . . . . . . . . . . . .
134
Installing the I/O Card . . . . . . . . . . . . . . .
135
book.book Page 7 Wednesday, January 20, 2010 10:20 AM iDRAC6 Enterprise Card (Optional) . . . . . . . . . . . 136
Installing an iDRAC6 Enterprise Card . . . . . . .
136
Removing an iDRAC6 Enterprise Card . . . . . . .
138
VFlash Media (Optional) . . . . . . . . . . . . . . . . .
139
Installing a VFlash Media Card . . . . . . . . . . .
139
Removing a VFlash Media Card . . . . . . . . . .
139
Internal Dual SD Module (Optional) . . . . . . . . . . .
139
Removing the Internal Dual SD Module . . . . . .
139
Installing the Internal Dual SD Module . . . . . . .
141
Internal SD Card (Optional) . . . . . . . . . . . . . . .
142
Installing an Internal SD Card . . . . . . . . . . .
142
Removing an Internal SD Card . . . . . . . . . . .
142
Integrated Storage Controller Card . . . . . . . . . . .
143
Removing the Integrated Storage
Controller Card . . . . . . . . . . . . . . . . . . .
143
Installing the Integrated Storage
Controller Card . . . . . . . . . . . . . . . . . . .
145
RAID Battery . . . . . . . . . . . . . . . . . . . . . . .
146
Removing a RAID Battery . . . . . . . . . . . . . .
146
Installing the RAID Battery . . . . . . . . . . . . .
147
Processors . . . . . . . . . . . . . . . . . . . . . . . .
148
Removing a Processor . . . . . . . . . . . . . . .
148
Installing a Processor . . . . . . . . . . . . . . .
152
Power Supplies . . . . . . . . . . . . . . . . . . . . .
154
Removing a Power Supply . . . . . . . . . . . . .
155
Installing a Power Supply . . . . . . . . . . . . .
156
Removing the Power Supply Blank . . . . . . . . .
157
Installing the Power Supply Blank . . . . . . . . .
157
Contents
7
book.book Page 8 Wednesday, January 20, 2010 10:20 AM
System Battery . . . . . . . . . . . . . . . . . . . . .
157
Replacing the System Battery . . . . . . . . . .
157
SAS Backplane . . . . . . . . . . . . . . . . . . . . .
159
Removing the SAS Backplane . . . . . . . . . .
159
Installing the SAS Backplane . . . . . . . . . . .
161
Power Distribution Board . . . . . . . . . . . . . . .
161
Removing the Power Distribution Board . . . . .
161
Replacing the Power Distribution Board . . . . .
163
Control Panel Assembly . . . . . . . . . . . . . . . .
163
Removing the Control Panel Display Module . . .
163
Installing the Control Panel Display Module . . .
164
Removing the Control Panel Board . . . . . . . .
166
Installing the Control Panel Board . . . . . . . .
167
System Board . . . . . . . . . . . . . . . . . . . . . .
168
Removing the System Board . . . . . . . . . . .
168
Installing the System Board . . . . . . . . . . . .
170
4
Troubleshooting Your System . . . . . . . .
173
Safety First—For You and Your System . . . . . . . .
173
Troubleshooting System Startup Failure . . . . . . . .
173
Troubleshooting External Connections . . . . . . . .
173
Troubleshooting the Video Subsystem . . . . . . . . .
174
Troubleshooting a USB Device . . . . . . . . . . . .
174
Troubleshooting a Serial I/O Device . . . . . . . . . .
175
Troubleshooting a NIC . . . . . . . . . . . . . . . . .
175
8
Contents
book.book Page 9 Wednesday, January 20, 2010 10:20 AM
Troubleshooting a Wet System . . . . . . . . . . . . .
176
Troubleshooting a Damaged System . . . . . . . . . .
177
Troubleshooting the System Battery . . . . . . . . . . .
178
Troubleshooting Power Supplies . . . . . . . . . . . .
179
Troubleshooting System Cooling Problems . . . . . . .
180
Troubleshooting a Fan . . . . . . . . . . . . . . .
180
Troubleshooting System Memory . . . . . . . . . . . .
181
Troubleshooting an Internal USB Key . . . . . . . . . .
183
Troubleshooting an Internal SD Card . . . . . . . . . .
184
Troubleshooting an Optical Drive . . . . . . . . . . . .
185
Troubleshooting a Tape Backup Unit . . . . . . . . . .
186
Troubleshooting a Hard Drive . . . . . . . . . . . . . .
186
Troubleshooting a Storage Controller . . . . . . . . . .
187
Troubleshooting Expansion Cards . . . . . . . . . . . .
189
Troubleshooting the Processors . . . . . . . . . . . . .
190
5
Running the System Diagnostics . . . . . .
193
Using Online Diagnostics . . . . . . . . . . . . . . . .
193
Embedded System Diagnostics Features . . . . . . . .
193
When to Use the Embedded System Diagnostics . . . .
194
Running the Embedded System Diagnostics . . . . . .
194
System Diagnostics Testing Options . . . . . . . . . .
194
Contents
9
book.book Page 10 Wednesday, January 20, 2010 10:20 AM
Using the Custom Test Options . . . . . . . . . . . .
195
Selecting Devices for Testing . . . . . . . . . . .
195
Selecting Diagnostics Options . . . . . . . . . .
195
Viewing Information and Results . . . . . . . . .
196
6
Jumpers and Connectors . . . . . . . . . . . .
197
System Board Jumper . . . . . . . . . . . . . . . . .
197
System Board Connectors . . . . . . . . . . . . . . .
198
SAS Backplane Board Connectors . . . . . . . . . .
200
Disabling a Forgotten Password . . . . . . . . . . . .
201
7
Getting Help . . . . . . . . . . . . . . . . . . . . . .
203
Contacting Dell . . . . . . . . . . . . . . . . . . . . .
203
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
10
Contents
book.book Page 11 Wednesday, January 20, 2010 10:20 AM
About Your System
Accessing System Features During Startup
The following keystrokes provide access to system features during startup.
Keystroke Description
<F2>
<F10>
Enters the System Setup program. See "Using the System Setup
Program and UEFI Boot Manager" on page 63.
Enters System Services, which opens the Lifecycle Controller. The
Lifecycle Controller allows you to access utilities such as embedded system diagnostics. For more information, see the Lifecycle Controller documentation.
<F11> Enters the BIOS Boot Manager or the UEFI Boot Manager,
depending on the system's boot configuration. See "Using the System
Setup Program and UEFI Boot Manager" on page 63.
Starts PXE boot.
<F12>
<Ctrl><E> Enters the iDRAC Configuration Utility, which allows access to the
System Event Log (SEL) and configuration of remote access to the system. For more information, see the iDRAC user documentation.
<Ctrl><C> Enters the SAS Configuration Utility. For more information, see the
SAS adapter documentation.
<Ctrl><R> Enters the PERC configuration utility. For more information, see the
PERC card documentation
<Ctrl><S> Enters the utility to configure NIC settings for PXE boot. For more information, see the documentation for your integrated NIC.
About Your System
11
book.book Page 12 Wednesday, January 20, 2010 10:20 AM
Front-Panel Features and Indicators
Figure 1-1.
Front-Panel Features and Indicators
1 2 3 4 5 6 7 8 9 10
12
Item Indicator, Button, or
Connector
1 Optical drive
(optional)
Icon
2 Power-on indicator, power button
Description
One optional slim-line SATA
DVD-ROM drive or DVD-RW drive.
NOTE:
DVD devices are data only.
The power-on indicator lights when the system power is on.
The power button controls the DC power supply output to the system.
When the system bezel is installed, the power button is not accessible.
NOTE:
When powering on the system, the video monitor can take from several seconds to over two minutes to display an image, depending on the amount of memory installed in the system.
NOTE:
On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off.
About Your System
book.book Page 13 Wednesday, January 20, 2010 10:20 AM
Item Indicator, Button, or
Connector
3 NMI button
Icon
6
7
4
5
USB connectors (2)
Video connector
LCD menu buttons
LCD panel
8 System identification button
Description
Used to troubleshoot software and device driver errors when using certain operating systems. This button can be pressed using the end of a paper clip.
Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.
Connect USB devices to the system. The ports are USB 2.0-compliant.
Connects a monitor to the system.
Allows you to navigate the control panel
LCD menu.
Provides system ID, status information, and system error messages.
The LCD lights blue during normal system operation. The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text.
NOTE:
If the system is connected to AC power and an error has been detected, the LCD lights amber regardless of whether the system has been powered on.
The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pushed, the LCD panel on the front and the blue system status indicator on the back blink until one of the buttons is pushed again.
About Your System
13
book.book Page 14 Wednesday, January 20, 2010 10:20 AM
Item Indicator, Button, or
Connector
9 System identification panel
Icon
10 Hard drives
Description
A slide-out panel for system information including the Express Service tag, embedded NIC MAC address, and iDRAC6 Enterprise card MAC address.
Space is provided for an additional label.
Up to sixteen 2.5-inch, external hot-swappable SAS or SSD hard drives.
NOTE:
Only one SATA drive is supported on the x4 backplane. SAS and SATA hard disks on the same backplane cannot be combined into a single virtual disk. x16 backplanes do not support SATA drives.
LCD Panel Features
The system's LCD panel provides system information and status and error messages to signify when the system is operating correctly or when the system
needs attention. See "LCD Status Messages" on page 23 for information
about specific status codes.
The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error condition. When the system is in standby mode, the LCD backlight is off and can be turned on by pressing either the Select,
Left or Right button on the LCD panel. The LCD backlight will remain off if
LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools.
14
About Your System
book.book Page 15 Wednesday, January 20, 2010 10:20 AM
Figure 1-2.
LCD Panel Features
1 2 3 4
Item
1
2
3
4
Buttons Description
Left
Select
Right
Moves the cursor back in one-step increments.
Selects the menu item highlighted by the cursor.
Moves the cursor forward in one-step increments.
During message scrolling:
• Press once to increase scrolling speed.
• Press again to stop.
• Press again to return to default scrolling speed.
• Press again to repeat the cycle.
System identification Turns the system ID mode on (LCD panel flashes blue) and off.
Press quickly to toggle the system ID on and off. If the system hangs during POST, press and hold the system ID button for more than five seconds to enter BIOS Progress mode.
Home Screen
The Home screen displays user-configurable information about the system.
This screen is displayed during normal system operation when there are no status messages or errors present. When the system is in standby mode, the
LCD backlight will turn off after five minutes of inactivity if there are no error messages. Press one of the three navigation buttons (Select, Left, or Right) to view the Home screen.
About Your System
15
book.book Page 16 Wednesday, January 20, 2010 10:20 AM
To navigate to the Home screen from another menu, continue to select the up arrow until the Home icon is displayed, and then select the Home icon.
From the Home screen, press the Select button to enter the main menu. See the following tables for information on the Setup and View submenus.
Setup Menu
NOTE:
When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.
Option
DRAC
Set error
Set home
Description
Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields are IP,
Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two separate DNS entries are available.
Select SEL to display LCD error messages in a format that matches the IPMI description in the SEL. This can be useful when trying to match an LCD message with an SEL entry.
Select Simple to display LCD error messages in a
simplified user-friendly description. See "LCD Status
Messages" on page 23 for a list of messages in this
format.
Select the default information to be displayed on the
LCD Home screen. See "View Menu" on page 17 to see
the options and option items that can be set as the default on the Home screen.
16
About Your System
book.book Page 17 Wednesday, January 20, 2010 10:20 AM
View Menu
Option
DRAC IP
MAC
Name
Number
Power
Temperature
Description
Displays the IPv4 or IPv6 addresses for the iDRAC6.
Addresses include DNS (Primary and Secondary),
Gateway, IP, and Subnet (IPv6 does not have Subnet).
Displays the MAC addresses for DRAC, iSCSIn, or
NETn.
Displays the name of the Host, Model, or User String for the system.
Displays the Asset tag or the Service tag for the system.
Displays the power output of the system in BTU/hr or
Watts. The display format can be configured in the Set
home submenu of the Setup menu. See "Setup Menu" on page 16.
Displays the temperature of the system in Celsius or
Fahrenheit. The display format can be configured in the
Set home submenu of the Setup menu. See "Setup
About Your System
17
book.book Page 18 Wednesday, January 20, 2010 10:20 AM
Hard-Drive Indicator Patterns
1
2
18
1 hard-drive activity indicator (green) 2 hard-drive status indicator (green and amber)
Drive-Status Indicator Pattern (RAID Only) Condition
Blinks green two times per second
Off
Identify drive/preparing for removal
Drive ready for insertion or removal
NOTE:
The drive status indicator remains off until all hard drives are initialized after system power is applied. Drives are not ready for insertion or removal during this time.
Blinks green, amber, and off Drive predicted failure
About Your System
book.book Page 19 Wednesday, January 20, 2010 10:20 AM
Drive-Status Indicator Pattern (RAID Only) Condition
Blinks amber four times per second
Blinks green slowly
Steady green
Blinks green three seconds, amber three seconds, and off six seconds
Drive failed
Drive rebuilding
Drive online
Rebuild aborted
Back-Panel Features and Indicators
Figure 1-3.
Back-Panel Features and Indicators
1 2 3 4 5 6
10 9 8 7
Item Indicator, Button, or
Connector
1 Ethernet or SFP+ connectors
Icon Description
Depending on the configuration, your system may have either a 1 GbE I/O riser or a 10 Gb I/O riser.
A 1 GbE I/O riser consists of four
Ethernet connectors and a 10 Gb I/O riser consists of two SFP+ and two
Ethernet connectors.
About Your System
19
book.book Page 20 Wednesday, January 20, 2010 10:20 AM
20
3
4
Item Indicator, Button, or
Connector
2 VFlash media slot
(optional)
Icon
5
USB connectors (2) iDRAC6 Enterprise port (optional)
PCIe expansion card slots (7)
6
7
8
Power supplies (4)
System identification connector
System identification button
Description
Connects an external SD memory card for the optional iDRAC6 Enterprise card.
Connect USB devices to the system. The ports are USB 2.0-compliant.
Dedicated management port for the optional iDRAC6 Enterprise card.
PCI Express Generation 1 and
Generation 2
Slot 1: PCIe x4 Gen2 half-length, full height
Slot 2–4: PCIe x8 Gen2 half-length, full height
Slot 5: PCIe x4 Gen1 half-length, full height
Slot 6: PCIe x8 Gen2 half-length, full height
Slot 7: PCIe x16 Gen2 half-length, half height
NOTE:
Slot 7 can be expanded to four additional PCIe x4 Gen2 low profile slots using an optional PCIe expansion riser.
1100 W or 750 W
Connects the optional system status indicator assembly through the optional cable management arm.
The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pushed, the LCD panel on the front and the blue system status indicator on the back blink until one of the buttons is pushed again.
About Your System
book.book Page 21 Wednesday, January 20, 2010 10:20 AM
Item Indicator, Button, or
Connector
9 Serial connector
Icon
10 Video connector
Description
Connects a serial device to the system.
Connects a VGA display to the system.
Guidelines for Connecting External Devices
• Turn off power to the system and external devices before attaching a new external device. Turn on any external devices before turning on the system
(unless the documentation for the device specifies otherwise).
• Ensure that the appropriate driver for the attached device has been installed on the system.
•
If necessary to enable ports on your system, use the "Using the System
Setup Program and UEFI Boot Manager" on page 63.
NIC Indicator Codes
1
2
1 link indicator 2 activity indicator
Indicator
Link and activity indicators are off
Link indicator is green
Indicator Code
The NIC is not connected to the network.
The NIC is connected to a valid network link at
1000 Mbps.
About Your System
21
book.book Page 22 Wednesday, January 20, 2010 10:20 AM
Indicator Indicator Code
Link indicator is amber The NIC is connected to a valid network link at
10/100 Mbps.
Activity indicator is green blinking
Network data is being sent or received.
Power Indicator Codes
The power supplies have indicators that show whether power is present or whether a power fault has occurred.
• Not lit — AC power is not connected.
• Green — In standby mode, a green light indicates that a valid AC source is connected to the power supply and that the power supply is operational.
When the system is on, a green light also indicates that the power supply is providing DC power to the system.
• Amber — Indicates a problem with the power supply.
• Alternating green and amber — When hot-adding a power supply, this indicates that the power supply is mismatched with the other power supply (a high output power supply and an energy smart power supply are installed in the same system). Replace the power supply that has the flashing indicator with a power supply that matches the capacity of the other installed power supply.
CAUTION:
When correcting a power supply mismatch, replace only the power supply with the flashing indicator. Swapping the opposite power supply to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to an Energy Smart configuration or vice versa, you must power down the system.
22
About Your System
book.book Page 23 Wednesday, January 20, 2010 10:20 AM
Figure 1-4.
Power Supply Status Indicator
1
2
1 Velcro strap 2 power supply status indicator
LCD Status Messages
The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management software documentation.
NOTE:
If your system fails to boot, press the System ID button for at least 5 seconds
until an error code appears on the LCD. Record the code, then see "Getting Help" on page 203.
Viewing Status Messages
If a system error occurs, the LCD screen will turn amber. Press the Select button to view the list of errors or status messages. Use the left and right buttons to highlight an error number, and press Select to view the error.
About Your System
23
book.book Page 24 Wednesday, January 20, 2010 10:20 AM
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a normal state. For other faults, you must take action to remove the message from the display:
• Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.
• Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately 10 seconds, reconnect the power cable, and restart the system.
NOTE:
The following LCD status messages are displayed in the simple format. See
"Setup Menu" on page 16 to select the format in which the messages are displayed.
Table 1-1.
LCD Status Messages
Code
E1000
Text
Failsafe voltage error.
Contact support.
Causes
Check the SEL for critical failure events.
Corrective Actions
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1114 Ambient Temp exceeds allowed
Ambient temperature has reached a point outside of the allowed range.
range.
E1116 Memory disabled, temp above range. Power cycle AC.
Memory has exceeded allowable temperature and has been disabled to prevent damage to the components.
Remove AC power to the system for 10 seconds and restart the system.
the problem persists, see
24
About Your System
book.book Page 25 Wednesday, January 20, 2010 10:20 AM
Code Text Causes
E1119 Chipset # temp out of range. Check
Chipset temperature has reached a point outside of the allowed range.
motherboard heatsinks.
Corrective Actions
E1120 CPU VCORE
Temp: "CPU
VCORE
Regulator temp exceeding range. Check fans".
The regulator temperature has reached a point outside of the allowed range.
E1121 CPU VCACHE
Temp: "CPU
VCACHE
Regulator temp exceeding range. Check fans".
The regulator temperature has reached a point outside of the allowed range.
E1122 Mem VR Temp :
"Mem Voltage
Regulator
The regulator temperature has reached a point outside of the allowed range.
temp exceeding range. Check fans".
E1210 Motherboard battery failure.
Check battery.
CMOS battery is missing or the voltage is outside of the allowable range.
About Your System
25
book.book Page 26 Wednesday, January 20, 2010 10:20 AM
26
Code
E1211
E1216
Text
RAID
Controller battery failure.
Check battery.
3.3V
Regulator failure.
Reseat PCIe cards.
Causes Corrective Actions
RAID battery is either missing, bad, or unable to recharge due to thermal issues.
Reseat the RAID battery
connector. See "Installing the RAID Battery" on page 147 and
Cooling Problems" on page 180.
3.3V voltage regulator failed. Remove and reseat the
PCIe expansion cards. If the problem persists, see
Storage backplane voltage regulator has failed.
Remove and reseat the backplane. If the problem
E1219 Disk
Backplane power failure.
Check BP power cable.
E1222 CPU # VCACHE
Regulator failure.
Contact support.
Processor voltage regulator failed.
Reseat the processor(s).
If the problem persists,
see "Getting Help" on page 203.
E122C CPU Power
Fault. Power cycle AC.
A power fault was detected when powering up the processor(s).
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E122E On-board regulator failed. Call support.
One of the on-board voltage regulators failed.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
About Your System
book.book Page 27 Wednesday, January 20, 2010 10:20 AM
Code Text
E1233 IO Riser power failure.
Reseat IO
Riser.
Causes
IO riser voltage regulator failed.
E1234 Memory Riser
# power failure.
Memory riser voltage regulator failed.
Reseat riser and DIMMs.
E1243 CPU # VCORE
Regulator failure.
Contact
Support.
Processor voltage regulator failed.
Corrective Actions
Reseat the I/O riser.
If the problem persists,
see "Getting Help" on page 203.
Reseat the memory riser.
If the problem persists,
see "Getting Help" on page 203.
E1244 Embedded 10Gb Insufficient standby power
NICs for 10 Gb embedded NICs.
disabled.
Check or add
PSUs.
E1245
E1310
CPU # VIO
Regulator failure.
Contact support.
Fan ## RPM exceeding range. Check fan.
Processor voltage regulator failed.
RPM of specified fan is outside of the intended operating range.
Reseat the processor. See
If the problem persists,
see "Getting Help" on page 203.
Reseat the power supplies.
If the problem persists,
see "Getting Help" on page 203.
Reseat the processor. See
If the problem persists,
see "Getting Help" on page 203.
About Your System
27
book.book Page 28 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
E1313 Fan redundancy lost. Check fans.
E1314 Critical system cooling loss.
Check fans.
The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.
Check LCD for additional scrolling messages. See
"Troubleshooting a Fan" on page 180.
All fans have been removed from system.
Ensure that the fans are properly installed. See
"Troubleshooting a Fan" on page 180.
E1410 System Fatal
Error detected.
A fatal system error has been detected.
Check LCD for additional scrolling messages.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1414 CPU # temp exceeding range. Check
CPU heatsink.
Specified processor is out of acceptable temperature range.
Ensure that the processor heat sinks are properly installed. See
E1418 CPU # not detected.
Check CPU is seated properly.
Specified processor is missing or bad, and the system is in an unsupported configuration.
Ensure that the specified processor is properly installed. See
E141C Unsupported
CPU configuration. Check
CPU or BIOS revision.
Processors are in an unsupported configuration.
Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system’s
Getting Started Guide.
28
About Your System
book.book Page 29 Wednesday, January 20, 2010 10:20 AM
Code Text Causes
E1614 Power Supply
# (### W) error. Check
Specified power supply failed.
power supply.
Corrective Actions
E141F CPU # protocol error. Power
The system BIOS reported a processor protocol error.
cycle AC.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1420 CPU Bus parity error.
The system BIOS reported a processor bus parity error.
Power cycle
AC.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1421 CPU # initializati on error.
Power cycle
AC.
The system BIOS reported a processor initialization error.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1422 CPU # machine check error.
The system BIOS reported a machine check error.
Power cycle
AC.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1610 Power Supply
# (### W) missing.
Specified power supply was removed or is missing from the system.
Check power supply.
About Your System
29
book.book Page 30 Wednesday, January 20, 2010 10:20 AM
30
Code Text Causes Corrective Actions
E1618 Predictive failure on
Power Supply
# (### W).
Check PSU.
A power supply fan failure, an over-temperature condition, or power supply communication error has caused the predictive warning of an impending power supply failure.
E161C Power Supply
# (### W) lost AC
Specified power supply is attached to the system, but it has lost its AC input.
power. Check
PSU cables.
Check the AC power source for the specified power supply. If the problem persists, see
E1620 Power Supply
# (### W) AC power error.
Check PSU cables.
Specified power supply's AC input is outside of the allowable range.
Check the AC power source for the specified power supply. If the problem persists, see
E1624
E1626 Power Supply
Mismatch.
PSU1 = ### W,
The power supplies in the system are not the same wattage.
PSU2 = ### W.
E1629
Lost power supply redundancy.
Check PSU cables.
Power required >
PSU wattage.
Check PSU and config.
The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down.
The system configuration requires more power than the power supplies can provide, even with throttling.
Ensure that power supplies with matching wattage are installed. See the Technical
Specifications outlined in your system’s Getting
Started Guide.
Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.
About Your System
book.book Page 31 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
E1631 System power The processors and memory draw exceeded throttling is not sufficient to threshold. keep system power
Contact support.
consumption below the maximum safe level with current power supply configuration.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1632 PowerSafe event.
Contact support.
The processors and memory have been throttled to keep system power consumption below the maximum safe level with current power supply configuration.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1710 I/O channel check error.
The system BIOS reported an I/O channel check.
Review & clear SEL.
Check the SEL for more information and then clear the SEL. Remove
AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1711 PCI parity error on Bus
## Device ##
Function ##.
The system BIOS reported a
PCI parity error on a component that resides in
PCI configuration space at bus ##, device ##, function ##.
Remove and reseat the
PCIe expansion cards. If the problem persists, see
PCI parity error on Slot
#. Review & clear SEL.
The system BIOS reported a
PCI parity error on a component that resides in the specified slot.
Remove and reseat the
PCIe expansion cards. If the problem persists, see
About Your System
31
book.book Page 32 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
E1712 PCI system error on Bus
## Device ##
Function ##.
The system BIOS reported a
PCI system error on a component that resides in
PCI configuration space at bus ##, device ##, function ##.
Remove and reseat the
PCIe expansion cards. If the problem persists, see
PCI system error on Slot
#. Review & clear SEL.
The system BIOS reported a
PCI system error on a component that resides in the specified slot.
Reinstall the expansion-
If the problem persists, the riser card or system board is faulty. See
E1714 Unknown error. Review
The system BIOS determined there has been
& clear SEL.
an error in the system, but is unable to determine its origin.
Check the SEL for more information and then clear the SEL. Remove
AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1715 Fatal I/O
Error. Review
& clear SEL.
The system BIOS determined there has been a fatal error in the system.
Check the SEL for more information, and then clear the SEL. Remove
AC power to the system for 10 seconds, and restart the system.
If the problem persists,
see "Getting Help" on page 203.
32
About Your System
book.book Page 33 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
E1716 Chipset IERR
Bus ## Dev ##
Function
Review &
##.
The system BIOS reported a chipset internal error that resides in bus ##, device
##, function ##.
clear SEL.
Check the SEL for more information, and then clear the SEL. Remove
AC power to the system for 10 seconds, and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E1717 CPU #
& clear SEL.
The system BIOS internal error. Review determined that the specified processor has had an internal error.
Check the SEL for more information, and then clear the SEL. Remove
AC power to the system for 10 seconds, and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E171F PCIe fatal error on Bus
## Device ##
Function ##.
The system BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
Remove and reseat the
PCIe expansion cards. If the problem persists, see
PCIe fatal error on Slot
#. Review & clear SEL.
The system BIOS has reported a PCIe fatal error on a component that resides in the specified slot.
Reinstall the expansion-
If the problem persists, the riser card or system board is faulty. See
E1810 Hard drive ## fault. Review
The specified hard drive experienced a fault.
& clear SEL.
About Your System
33
book.book Page 34 Wednesday, January 20, 2010 10:20 AM
Code Text
E1A14 SAS cable A failure.
Check connection.
Causes
SAS cable A is missing or bad.
Corrective Actions
E1812 Hard drive ## removed.
Check drive.
The specified hard drive has been removed from the system.
Information only.
E1813 Internal Dual The internal dual SD
SD Module module card has failed.
Card # failed. Check
SD card.
Reseat the internal dual
SD module card.
If the problem persists,
see "Getting Help" on page 203.
E1814 Internal SD
Module Card # writeprotected.
Check SD
The internal dual SD module card is writeprotected and cannot be used.
card.
Change the write-protect switch setting on SD card.
E1815 Internal Dual
SD Module redundancy
The internal dual SD module bootable media is no longer redundant.
lost. Check
SD cards.
Initiate a rebuild on the next POST execution.
Reseat the internal dual
SD module card. See
If the problem persists,
see "Getting Help" on page 203.
Reseat the cable. If the problem persists, replace cable.
If the problem persists,
see "Getting Help" on page 203.
34
About Your System
book.book Page 35 Wednesday, January 20, 2010 10:20 AM
Code Text Causes
E2013 BIOS unable The system BIOS failed to to shadow memory. Check copy its flash image into memory.
DIMMs.
Corrective Actions
E1A15 SAS cable B failure.
Check connection.
SAS cable B is missing or bad.
Reseat the cable. If the problem persists, replace cable.
If the problem persists,
see "Getting Help" on page 203
E1A1D Control panel USB cable to the control
USB cable not panel is missing or bad.
E2010 detected.
Check cable.
Memory not detected.
Inspect
DIMMs.
Reseat the cable. If the problem persists, replace cable.
If the problem persists,
see "Getting Help" on page 203.
No memory was detected in the system.
Install memory or reseat the memory risers and memory modules. See
E2011 Memory configuratio n failure.
Check DIMMs.
Memory detected, but is not configurable. Error detected during memory configuration.
E2012 Memory configured but unusable.
Check DIMMs.
Memory configured, but is unusable.
About Your System
35
book.book Page 36 Wednesday, January 20, 2010 10:20 AM
36
Code Text Causes Corrective Actions
E2014 CMOS RAM failure.
Power cycle
AC.
CMOS failure. CMOS RAM not functioning properly.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E2015
E2016
DMA
Controller failure.
Power cycle
AC.
Interrupt
Controller failure.
Power cycle
AC.
DMA controller failure.
Interrupt controller failure.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E2017 Timer refresh Timer refresh failure.
failure.
Power cycle
AC.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E2018 Programmable
Timer error.
Power cycle
Programmable interval timer error.
AC.
E2019 Parity error.
Power cycle
AC.
Parity error.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
About Your System
book.book Page 37 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
E201A SuperIO failure.
Power cycle
AC.
SIO failure.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E201B Keyboard
Controller error. Power cycle AC.
Keyboard controller failure. Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E201C SMI initializati on failure.
Power cycle
AC.
System management interrupt (SMI) initialization failure.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
see "Getting Help" on page 203.
E201D Shutdown test BIOS shutdown test failure. Remove AC power to the failure. system for 10 seconds and
Power cycle restart the system.
AC.
If the problem persists,
see "Getting Help" on page 203.
E201E POST memory BIOS POST memory test test failure. failure.
Check DIMMs.
If the problem persists,
see "Getting Help" on page 203.
E2020 CPU configuratio n failure.
Check screen message.
Processor configuration failure.
Check screen for specific error messages. See
About Your System
37
book.book Page 38 Wednesday, January 20, 2010 10:20 AM
Code Text Causes
E2021 Incorrect memory configuration. Review
User Guide.
Incorrect memory configuration.
Corrective Actions
Check screen for specific error messages. See
E2022 General failure during POST.
General failure after video.
Check screen for specific error messages.
Check screen message.
E2025 QPI initializati on error.
Contact support.
QuickPath Interconnect
(QPI) failure.
See "Getting Help" on page 203.
E2026 Memory initializati on error.
Contact support.
Invalid memory configuration.
Ensure that the memory modules are installed in a valid configuration. See
Installation Guidelines" on page 92. See "Getting
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
The memory module in slot
"##" has had a multi-bit error (MBE).
E2111 SBE log disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has disabled memory single-bit error (SBE) logging and will not log any more SBEs until the system is rebooted. "##" represents the memory module implicated by the
BIOS.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
38
About Your System
book.book Page 39 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
E2112 Memory spared The system BIOS spared the on Card x
DIMM ##.
Power cycle memory because it has determined the memory has too many errors.
AC.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC.
The system BIOS disabled memory mirroring because it has determined one half of the mirror has had too many errors. "## & ##" represents the memory module pair implicated by the BIOS.
I1910 Intrusion detected.
Check chassis cover.
System cover has been removed.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists,
Information only.
Check the SEL for details on the events.
Remove AC power to the system for 10 seconds or clear the SEL.
I1911 LCD Log Full.
Check SEL to review all
Errors.
LCD overflow message. A maximum of ten error messages can display sequentially on the LCD.
The eleventh message instructs the user to check the SEL for details on the events.
I1912 SEL full.
Review & clear log.
The SEL is full of events and is unable to log any more.
W1100 CPU VCORE
Regulator temp exceeding range. Check fans.
The regulator temperature has reached a point outside of the allowed range.
Check the SEL for more information and then clear the SEL.
the problem persists, see
About Your System
39
book.book Page 40 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
W1101 CPU VCACHE
Regulator temp exceeding range. Check fans.
The regulator temperature has reached a point outside of the allowed range.
W1102 Mem Voltage
Regulator temp exceeding range. Check fans
The regulator temperature has reached a point outside of the allowed range.
W1228
W1627
RAID
Controller battery capacity <
24hr.
Power required >
PSU wattage.
Check PSU and config.
W1628 Performance degraded.
Check PSU and system configuration.
Warns predictively that the
RAID battery has less than
24 hours of charge left.
The system configuration requires more power than what the power supply can provide.
The system configuration requires more power than what the power supply can provide, but it can boot if throttled.
the problem persists, see
the problem persists, see
Allow RAID battery to charge to greater than 24 hours of sustained charge.
If problem persists, replace the RAID battery.
Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.
Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.
40
About Your System
book.book Page 41 Wednesday, January 20, 2010 10:20 AM
Code Text Causes Corrective Actions
W1630 Power supply redundancy degraded.
Check PSU cables.
The power supply subsystem is no longer fully redundant, but at least one more supply can fail before the system is at risk of shutting down.
Reseat the power supplies.
If the problem persists,
see "Getting Help" on page 203.
NOTE:
For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
System Messages
System messages appear on the screen to notify you of a possible problem with the system.
NOTE:
If you receive a system message not listed in the table, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.
Table 1-2.
System Messages
Message Causes Corrective Actions
Alert! iDRAC6 not responding.
Rebooting.
The iDRAC6 is not responding to BIOS communication either because it is not functioning properly or has not completed initialization. The system will reboot.
Wait for the system to reboot.
About Your System
41
book.book Page 42 Wednesday, January 20, 2010 10:20 AM
Message Causes
Alert! iDRAC6 not The iDRAC6 is hung.
responding.
Power required may exceed PSU wattage.
The iDRAC6 was remotely reset while system was booting
Alert!
Continuing
After AC recovery, the iDRAC6 takes longer than normal to boot.
system boot accepts the risk that system may power down without warning.
Corrective Actions
Remove AC power to the system for 10 seconds and restart the system.
Alert! Node
Interleaving disabled! Memory configuration does not support
Node
Interleaving.
The memory configuration does not support node interleaving, or the configuration has changed
(for example, a memory module has failed) so that node interleaving cannot be supported. The system will run but without node interleaving.
Ensure that the memory modules are installed in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information,
the problem persists, see
42
About Your System
book.book Page 43 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Alert! Power required exceeds
PSU wattage.
Check PSU and system configuration.
Alert!
Continuing system boot accepts the risk that system may power down without warning.
Alert! Redundant memory disabled!
Memory configuration does not support redundant memory.
Alert! System fatal error during previous boot.
The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies.
Memory Mirroring was enabled in the system setup program, but the current configuration does not support redundant memory.
A memory module may be faulty.
If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High
Output power supplies to use
Check the memory modules for failure. See
the memory setting, if
UEFI Boot Manager" on page 63.
An error caused the system to reboot.
Check other system messages for additional information for possible causes.
System is in manufacturing mode.
Reboot to take the system out of manufacturing mode.
BIOS
MANUFACTURING
MODE detected.
MANUFACTURING
MODE will be cleared before the next boot.
System reboot required for normal operation.
About Your System
43
book.book Page 44 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
BIOS Update
Attempt Failed!
Remote BIOS update attempt failed.
Retry the BIOS update. If problem persists, see
Caution!
NVRAM_CLR jumper is installed on system board.
NVRAM_CLR jumper is installed in the clear setting.
CMOS has been cleared.
Move the NVRAM_CLR jumper to the default position (pins 3 and 5). See
location. Restart the system and re-enter the BIOS
UEFI Boot Manager" on page 63.
CPU set to minimum frequency.
CPUs with different cache sizes detected.
CPUs with different core sizes detected!
System halted
The processor speed may be intentionally set lower for power conservation.
If not an intentional setting, check any other system messages for possible causes.
Mismatched processors have been installed in the system.
Ensure that all processors have the same cache size, number of cores and logical processors, and power rating.
Ensure that the processors are properly installed. See
CPUs with different logical processors detected! System halted.
CPUs with different power rating detected!
System halted.
44
About Your System
book.book Page 45 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Current boot mode is set to UEFI.
Please ensure compatible bootable media is
The system failed to boot because UEFI boot mode is enabled in BIOS and the boot operating system is non-
UEFI. available. Use the system setup
Ensure that the boot mode is set correctly and that the proper bootable media is
UEFI Boot Manager" on page 63.
program to change the boot mode as needed.
Embedded NIC x and
NIC y:
OS NIC= <ENABLED
|DISABLED>,
Management
Shared NIC=
The operating system NIC interface is set in BIOS. The
Management Shared NIC interface is set in management tools.
<ENABLED
|DISABLED>
Check the system management software or the
System Setup program for
NIC settings. If a problem is indicated, see
"Troubleshooting a NIC" on page 175.
Error 8602 -
Auxiliary Device
Failure. Verify
Mouse or keyboard cable is loose or improperly connected.
that mouse and keyboard are securely attached to
Reseat the mouse or keyboard cable.
Defective mouse or keyboard. Ensure that the mouse or keyboard is operational. See
correct connectors.
Gate A20 failure Faulty keyboard controller; faulty system board.
General failure The operating system is unable to carry out the command.
See "Getting Help" on page 203.
This message is usually followed by specific information. Note the information, and take the appropriate action to resolve the problem.
About Your System
45
book.book Page 46 Wednesday, January 20, 2010 10:20 AM
Message
Invalid configuration information - please run SETUP program.
Causes
An invalid system configuration caused a system halt.
Invalid PCIe card found in the
Internal_Storage slot!
The system halted because an invalid PCIe expansion card is installed in the dedicated storage controller slot.
Keyboard controller failure
Faulty keyboard controller; faulty system board
Corrective Actions
Run the System Setup program and review the
current settings. See "Using the System Setup Program and UEFI Boot Manager" on page 63.
Remove the PCIe expansion card and install the integrated storage controller in the dedicated slot. See
See "Getting Help" on page 203.
Keyboard data line failure
Keyboard stuck key failure
Keyboard cable connector is improperly connected or the keyboard is defective.
Reseat the keyboard cable. If the problem persists, see
Keyboard fuse has failed
Overcurrent detected at the keyboard connector.
Local keyboard may not work because all user accessible USB
The USB ports are disabled in the system BIOS.
ports are disabled. If operating locally, power cycle the system and enter system setup program to change settings.
See "Getting Help" on page 203.
Power down and restart the system from the power button, and then enter the
System Setup program to enable the USB port(s). See
46
About Your System
book.book Page 47 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Memory Riser <x> disabled - SMI channel training
The memory riser connector is not properly seated.
failure.
Memory Riser <x> disabled - Memory
The memory riser connector or the processor socket may be exposed to dust.
The processor has bent pins.
Buffer communication error.
Reseat the memory riser(s).
"Installing a Memory Riser" on page 101.
Ensure that the memory riser connectors and processor sockets are clean.
Verify that there are no bent pins on the processor. If the processor has bent pins, see
Memory Riser <x> disabled -
MemBIST error.
Memory Riser <x> disabled -
MemBIST timeout.
Memory Riser <x> disabled - Rank not found.
Memory riser <x> disabled - DIMM communication error
The memory modules are not properly seated.
The memory module connector may be exposed to dust.
Replace or reseat the memory module(s). See
"Installing Memory Modules" on page 102.
Unsupported memory module.
Ensure that the memory module connectors are clean and supported memory modules are installed in a valid configuration. See
Installation Guidelines" on page 92.
Memory Riser <x> disabled - DDR training failure
Memory Riser <x> disabled - Simple memory test failure.
About Your System
47
book.book Page 48 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Memory Riser <x> disabled - No
Memory detected.
The memory modules are not properly seated.
The memory module connector may be exposed to dust.
Replace or reseat the memory module(s). See
"Installing Memory Modules" on page 102.
Unsupported memory module.
Verify that the memory modules are identical and not in a locked step pair.
Memory Riser <x> disabled -
Invalid DIMM.
Unsupported memory modules in the first locked step pair.
Replace the memory
Memory Modules" on page 105 and "Installing
Memory Riser <x> disabled - No
DIMM detected.
An empty memory riser is installed.
DIMM unsupported:
Memory Riser <x>
DIMM<y>
Memory Riser<x>
Lockstep pair
DIMM <y & z> disabled
Please replace the DIMM or remove the lockstep pair
Unsupported memory modules on slots 3 to 8.
Install memory modules in
Ensure that the memory modules are installed in a valid configuration. See
Installation Guidelines" on page 92.
48
About Your System
book.book Page 49 Wednesday, January 20, 2010 10:20 AM
Message Causes
DIMM mismatch:
Memory Riser <x>
Lockstep Pair
Locked step pairs do not match.
DIMM <y & z> disabled.
Please replace the lockstep pair with matching
DIMM(s).
Corrective Actions
Ensure that the memory modules match for a locked
MemBIST timeout:
Memory riser<x>
Locstep Pair DIMM
The memory modules are not properly seated.
<x & y> disabled.
Please replace
The memory module connector may be exposed to dust.
the DIMM(s) or remove the
Faulty memory module.
lockstep pair.
Replace or reseat the memory module(s). See
"Installing Memory Modules" on page 102.
Ensure that the memory module connectors are clean.
MemBIST error:
Memory riser(s)
<x> Locstep Pair
DIMM <x & y> disabled.
Please replace the DIMM(s) or remove the lockstep pair.
DDR training
Error: Memory riser <x> DIMM
<y>
Memory riser <x> lockstep pair <y
& z> disabled.
Please replace the DIMM(s) or remove the lockstep pair.
About Your System
49
book.book Page 50 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
DIMM population violation:
Memory riser <x>
DIMM <y>
Memory riser <x>
While mixing different rank memory modules, the lower rank memory modules are installed on slots 1 and 2 or on slots 5 and 6.
lockstep pair
DIMM <x & y> disabled.
Ensure that the memory modules are installed in a valid configuration. See
Installation Guidelines" on page 92.
Please populate
DIMM(s) with largest number of ranks in the lowest slot.
DDR Channel
Disabled.
Memory riser <x> lockstep pair
DIMM <y & z> disabled.
Memory riser <x> lockstep pair
DIMM <y & z> disabled.
Please ensure each lockstep pair is installed correctly.
50
About Your System
book.book Page 51 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
DellMemBIST timeout: Memory riser <x> DIMM
The memory modules are not properly seated.
<y>
Memory riser <x>
The memory module connector may be exposed to dust.
lockstep pair
DIMM <x & y>
Faulty memory module.
disabled.
Replace or reseat the memory module(s). See
"Installing Memory Modules" on page 102.
Ensure that the memory module connectors are clean.
Please replace the DIMM(s) or remove the lockstep pair.
DellMemBIST error: Memory riser <x> DIMM
<y>
Memory riser <x> lockstep pair
DIMM <x & y> disabled.
Please replace the DIMM or remove the lockstep pair.
Manufacturing mode detected.
Memory address line failure at address, read value expecting value.
System is in manufacturing mode.
Reboot to take the system out of manufacturing mode.
Faulty or improperly installed memory modules.
Memory double word logic failure at address, read value expecting value.
Faulty or improperly installed memory modules.
About Your System
51
book.book Page 52 Wednesday, January 20, 2010 10:20 AM
Message
Memory write/read failure at address, read value expecting value.
Causes Corrective Actions
Memory
Initialization
Warning: Memory size may be reduced.
Invalid memory configuration. The system will run but with less memory than is physically available.
Ensure that the memory modules are installed in a valid configuration. See
Installation Guidelines" on page 92.
Memory odd/even logic failure at address, read value expecting value.
Faulty or improperly installed memory modules.
Faulty or improperly installed memory modules.
Memory set to minimum frequency.
Memory tests terminated by keystroke.
The memory frequency may be intentionally set lower for power conservation.
If not an intentional setting, check any other system messages for possible causes.
The current memory configuration may support only the minimum frequency.
Ensure that your memory configuration supports the higher frequency. See
Installation Guidelines" on page 92.
POST memory test was terminated by pressing a key.
Information only.
52
About Your System
book.book Page 53 Wednesday, January 20, 2010 10:20 AM
Message
No boot device available.
No boot sector on hard drive.
No timer tick interrupt.
PCI BIOS failed to install.
Causes
Faulty or missing optical drive subsystem, hard drive, or hard-drive subsystem, or no bootable USB key installed.
Incorrect configuration settings in System Setup program, or no operating system on hard drive.
Faulty system board.
PCIe device BIOS (Option
ROM) checksum failure detected during shadowing.
Cables to expansion card(s) loose; faulty or improperly installed expansion card(s).
Corrective Actions
Use a bootable USB key, CD, or hard drive. If the problem persists, see
information on setting the order of boot devices.
Check the hard-drive configuration settings in the
System Setup program. See
necessary, install the operating system on your hard drive. See your operating system documentation.
See "Getting Help" on page 203.
Reseat the expansion card(s).
Ensure that all appropriate cables are securely connected to the expansion card(s). If the problem persists, see
About Your System
53
book.book Page 54 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
PCIe Training
Error: Expected
Link Width is x,
Actual Link Width is y.
Faulty or improperly installed
PCIe card in the specified slot.
Reseat the PCIe card in the specified slot number. See
problem persists, see
Plug & Play
Configuration
Error.
Error encountered in initializing PCIe device; faulty system board.
Install the NVRAM_CLR jumper in the clear position
(pins 1 and 3) and reboot the
jumper location. If the problem persists, see
Read fault
Requested sector not found.
The operating system cannot read from the hard drive, optical drive, or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.
Replace the optical medium,
USB medium or device.
Ensure that the SAS backplane, USB, or SATA cables are properly connected. See
appropriate drive(s) installed in your system.
SATA Port x device not found.
There is no device connected to the specified SATA port.
Information only.
54
About Your System
book.book Page 55 Wednesday, January 20, 2010 10:20 AM
Message
SATA port x device autosensing error
SATA port x device configuration error.
Causes
The drive connected to the specified SATA port is faulty.
Corrective Actions
Replace the faulty drive.
SATA port x device error
Sector not found
Seek error
Seek operation failed
Shutdown failure
Faulty hard drive, USB device, or USB medium.
General system error.
Replace the USB medium or device. Ensure that the USB or SAS backplane cables are properly connected. See
appropriate drive(s) installed in your system.
See "Getting Help" on page 203.
The amount of system memory has changed.
Time-of-day clock stopped.
Memory has been added or removed or a memory module may be faulty.
If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See
Faulty battery or faulty chip. See "Troubleshooting the
About Your System
55
book.book Page 56 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Time-of-day not set - please run
SETUP program.
Incorrect Time or Date settings; faulty system battery.
Check the Time and Date
UEFI Boot Manager" on page 63. If the problem
persists, replace the system
battery. See "System Battery" on page 157.
Timer chip counter 2 failed.
Faulty system board.
See "Getting Help" on page 203.
Information only.
TPM or TCM configuration operation honored. System will now reset.
A Trusted Platform Module
(TPM) or China Trusted
Computing Model (TCM) configuration command has been entered. The system will reboot and execute the command.
TPM or TCM configuration operation is pending. Press
(I) to Ignore OR
(M) to Modify to allow this change and reset the system.
This message displays during system restart after a TPM or
TCM configuration command has been entered.
User interaction is required to proceed.
Enter I or M to proceed.
WARNING:
Modifying could prevent security.
TPM or TCM failure.
A TPM or TCM function has failed.
See "Getting Help" on page 203.
56
About Your System
book.book Page 57 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Unable to launch
System Services image. System halted!
System halted after F10 keystroke because System
Services image is either corrupted in the system firmware or has been lost due to system board replacement.
Restart the system and update the Lifecycle
Controller repository to the latest software to restore full functionality. See the
Lifecycle Controller user documentation for more information.
The iDRAC6 Enterprise card flash memory may be corrupted.
Restore the flash memory using the latest version on support.dell.com. See the iDRAC6 user's guide for instructions on performing a field replacement of the flash memory.
Unexpected interrupt in protected mode.
Unsupported CPU combination.
Improperly seated memory modules or faulty keyboard/mouse controller chip.
Reseat the memory modules.
problem persists, see
Processor(s) is not supported by the system.
Install a supported processor or processor combination.
Unsupported CPU stepping detected.
Warning: A fatal error has caused system reset!
Please check the
A fatal system error occurred and caused the system to reboot. system event log!
Check the SEL for information that was logged during the error. See the applicable troubleshooting
any faulty components specified in the SEL.
About Your System
57
book.book Page 58 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
Warning: Control
Panel is not installed.
The control panel is not installed or has a faulty cable connection.
Install the control panel, or check the cable connections between the display module, the control panel board, and the system board. See
"Control Panel Assembly" on page 163.
Warning! No micro Micro code update failed.
code update loaded for processor n.
Update the BIOS firmware.
See "Getting Help" on page 203.
Warning! Power required exceeds
PSU wattage.
Check PSU and system configuration.
The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies.
Warning!
Performance degraded. CPU and memory set to minimum frequencies to meet PSU wattage.
System will reboot.
If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High
Output power supplies to use
Warning! PSU mismatch. PSU redundancy lost.
Check PSU.
A High Output power supply and an Energy Smart power supply are installed in the system at the same time.
Install two High Output or two Energy Smart power supplies in the system.
You can also run the system on one power supply until you can obtain two power supplies of the same type.
58
About Your System
book.book Page 59 Wednesday, January 20, 2010 10:20 AM
Message Causes Corrective Actions
The memory configuration is not optimal. The recommended memory configuration is: <message>
Write fault
Write fault on selected drive.
Invalid memory configuration. The system will run but with reduced functionality.
Ensure that the memory modules are installed in a valid configuration. See
Installation Guidelines" on page 92. If the problem
persists, see
Faulty USB device, USB medium, optical drive assembly, hard drive, or harddrive subsystem.
Replace the USB medium or device. Ensure that the USB,
SAS backplane, or SATA cables are properly connected. See
Warning: QPI links operating in Slow Speed
Mode.
Warning: QPI link between <Agent X>
Port <Y> and
<Agent X1> <Port
Y1> failed.
The processor has bent pins.
The processor is not properly seated on the processor socket.
Verify that there are no bent pins on the processor. If the processor has bent pins, see
Reseat the processors. See
"Removing a Processor" on page 148 and "Installing a
If the problem persists, see
Warning: QPI link between <Agent X>
Port <Y> and
<Agent X1> <Port
Y1> degraded to half-width.
NOTE:
For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
About Your System
59
book.book Page 60 Wednesday, January 20, 2010 10:20 AM
Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette.
Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).
NOTE:
Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application.
Diagnostics Messages
The system diagnostic utilities may issue messages if you run diagnostic tests
on your system. See "Running the System Diagnostics" on page 193 for more
information about system diagnostics.
Alert Messages
Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.
Other Information You May Need
WARNING:
See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document.
• The rack documentation included with your rack solution describes how to install your system into a rack.
• The Getting Started Guide provides an overview of system features, setting up your system, and technical specifications.
60
About Your System
book.book Page 61 Wednesday, January 20, 2010 10:20 AM
• Dell systems management application documentation at support.dell.com/manuals provides information about installing and using the systems management software.
• Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.
NOTE:
Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents.
About Your System
61
book.book Page 62 Wednesday, January 20, 2010 10:20 AM
62
About Your System
book.book Page 63 Wednesday, January 20, 2010 10:20 AM
Using the System Setup Program and UEFI Boot Manager
The System Setup program is the BIOS program that enables you to manage your system hardware and specify BIOS-level options. From the System Setup program, you can:
• Change the NVRAM settings after you add or remove hardware
• View the system hardware configuration
• Enable or disable integrated devices
• Set performance and power management thresholds
• Manage system security
Choosing the System Boot Mode
The System Setup program also enables you to specify the boot mode for installing your operating system:
• BIOS boot mode (the default) is the standard BIOS-level boot interface.
• UEFI boot mode is an enhanced 64-bit boot interface based on Unified
Extensible Firmware Interface (UEFI) specifications that overlays the
system BIOS. See "Entering the UEFI Boot Manager" on page 76 for more
information on this interface.
You must select the boot mode in the Boot Mode field of the "Boot Settings
Screen" on page 69 screen of the System Setup program. Once you specify the
boot mode, the system boots in the specified boot mode and you proceed then to install your operating system from that mode. Thereafter, you must boot the system to the same boot mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating system from the other boot mode will cause the system to halt immediately at startup.
NOTE:
Operating systems must be UEFI-compatible (for example, Microsoft
®
Windows Server
®
2008 x64 version) to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the
BIOS boot mode.
Using the System Setup Program and UEFI Boot Manager
63
book.book Page 64 Wednesday, January 20, 2010 10:20 AM
Entering the System Setup Program
1 Turn on or restart your system.
2 Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart your system and try again.
Responding to Error Messages
If an error message appears while the system is booting, make a note of the
message. See "System Messages" on page 41 for an explanation of the message
and suggestions for correcting errors.
NOTE:
After installing a memory upgrade, it is normal for your system to display a message the first time you start your system.
Using the System Setup Program Navigation Keys
Keys
Up arrow or <Shift><Tab>
Down arrow or <Tab>
Spacebar, <+>, < – >, left and right arrows
<Esc>
<F1>
Action
Moves to the previous field.
Moves to the next field.
Cycles through the settings in a field. In many fields, you can also type the appropriate value.
Exits the System Setup program and restarts the system if any changes were made.
Displays the System Setup program ' s help file.
NOTE:
For most of the options, any changes that you make are recorded but do not take effect until you restart the system.
64
Using the System Setup Program and UEFI Boot Manager
book.book Page 65 Wednesday, January 20, 2010 10:20 AM
System Setup Options
Main Screen
NOTE:
The options for the System Setup program change based on the system configuration.
NOTE:
The System Setup program defaults are listed under their respective options in the following sections, where applicable.
Option
System Time
System Date
Memory Settings
Processor Settings
Description
Sets the time on the system's internal clock.
Sets the date on the system's internal calendar.
Displays information related to installed memory. See
"Memory Settings Screen" on page 67.
Displays information related to processors (speed,
cache size, and so on). See "Processor Settings Screen" on page 68.
Using the System Setup Program and UEFI Boot Manager
65
book.book Page 66 Wednesday, January 20, 2010 10:20 AM
Option
SATA Settings
Boot Settings
Integrated Devices
PCI IRQ Assignment
Serial Communication
Embedded Server
Management
Power Management
System Security
Keyboard NumLock
( On default)
Description
Displays a screen to enable or disable the integrated
SATA controller and ports. See "SATA Settings Screen" on page 69.
Displays a screen to specify the boot mode (BIOS or
UEFI). For BIOS boot mode, you can also specify the
boot devices. See "Boot Settings Screen" on page 69.
Displays a screen to enable or disable integrated device controllers and ports, and to specify related features
and options. See "Integrated Devices Screen" on page 70.
Displays a screen to change the IRQ assigned to each of the integrated devices on the PCI bus, and any installed
expansion card that requires an IRQ. See "PCI IRQ
Assignments Screen" on page 71.
Displays a screen to enable or disable the serial ports
and specify related features and options. See "Serial
Communication Screen" on page 72.
Displays a screen to configure the front-panel LCD options and to set a user-defined LCD string. See
"Embedded Server Management Screen" on page 73.
Enables you to manage power usage of the processor(s), fans, and memory modules with preconfigured or
customized settings. See "Power Management Screen" on page 73.
Displays a screen to configure the system password and
setup password features. See "System Security Screen"
on page 74, "Using the System Password" on page 79,
and "Using the Setup Password" on page 81 for more
information.
Determines whether your system starts up with the
NumLock mode activated on 101- or 102-key keyboards
(does not apply to 84-key keyboards).
66
Using the System Setup Program and UEFI Boot Manager
book.book Page 67 Wednesday, January 20, 2010 10:20 AM
Option
Report Keyboard Errors
( Report default)
F1/F2 Prompt on Error
(Enabled default)
Description
Enables or disables reporting of keyboard errors during the POST. Select Report for host systems that have keyboards attached. Select Do Not Report to suppress all error messages relating to the keyboard or keyboard controller during POST. This setting does not affect the operation of the keyboard itself if a keyboard is attached to the system.
Enables the system to halt on errors during POST, which allows the user to observe events that may scroll by unnoticed during normal POST. The user can press
<F1> to continue or <F2> to enter the System Setup program.
CAUTION:
When setting this option to Disabled, the system will not halt if an error occurs during
POST. Any critical errors will be displayed and logged in the system event log.
Memory Settings Screen
Option
System Memory Size
System Memory Type
System Memory Speed
Video Memory
System Memory Testing
(Enabled default)
Redundant Memory
(Disabled default)
Node Interleaving
(Disabled default)
Description
Displays the amount of system memory.
Displays the type of system memory.
Displays the system memory speed.
Displays the amount of video memory.
Specifies whether system memory tests are run at system boot. Options are Enabled and Disabled.
Specifies whether redundant memory is enabled on the system. Options are Mirror Mode, Spare Mode, and
Disabled.
If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If
Disabled, the system supports Non-Uniform Memory architecture (NUMA) (asymmetric) memory configurations.
Using the System Setup Program and UEFI Boot Manager
67
book.book Page 68 Wednesday, January 20, 2010 10:20 AM
Processor Settings Screen
Option
64-bit
Core Speed
Bus Speed
Logical Processor
(Enabled default)
Virtualization Technology
(Disabled default)
Adjacent Cache Line
Prefetch
(Enabled default)
Hardware Prefetcher
(Enabled default)
Execute Disable
(Enabled default)
Number of Cores per
Processor
(All default)
Turbo Mode
Description
Specifies if the processor(s) support 64-bit extensions.
Displays the processor clock speed.
Displays the processor bus speed.
On processors that support Simultaneous Multi-
Threading (SMT) technology, each processor core supports up to two logical processors. If this field is set to
Enabled, the BIOS reports both logical processors. If set to Disabled, only one logical processor is monitored by the BIOS.
Enabled permits virtualization software to use the virtualization technology incorporated in the processor.
NOTE:
Disable this feature if your system will not be running virtualization software.
Enable or disables system optimization for sequential memory access.
Enables or disables the hardware prefetcher.
Enables or disables Execute Disable Memory Protection
Technology.
If set to All, the maximum number of cores in each processor is enabled.
C1E
(Enabled default)
C States
Processor Family-Model-
Stepping
If Turbo Boost Technology is supported by the processor(s), enables or disables Turbo Mode.
When set to Enabled, the processor can switch to a minimum performance state when idle.
When set to Enabled, the processor(s) can operate in all available power states.
Displays the family, model, and stepping of the selected processor.
68
Using the System Setup Program and UEFI Boot Manager
book.book Page 69 Wednesday, January 20, 2010 10:20 AM
SATA Settings Screen
Option
Embedded SATA
(Off default)
Port A
(Off default)
Description
ATA Mode enables the integrated SATA controller. Off disables the controller.
Auto enables BIOS support for the device attached to
SATA port A. Off disables BIOS support for the device.
Boot Settings Screen
Option
Boot Mode
(BIOS default)
Boot Sequence
Hard-Disk Drive
Sequence
Description
CAUTION:
Switching the boot mode could prevent the system from booting if the operating system was not installed in the same boot mode.
If the system operating system supports Unified
Extensible Firmware Interface, you can set this option to
UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems.
NOTE:
Setting this field to UEFI disables the Boot
Sequence, Hard-Disk Drive Sequence, and USB Flash Drive
Emulation Type fields.
If Boot Mode is set to BIOS, this field tells the system where the operating system files needed for startup are located. If Boot Mode is set to UEFI, you can access the
UEFI boot manager utility by rebooting the system and pressing <F11> when prompted to do so.
Determines the order in which the BIOS attempts to boot from hard drives in the system during system startup.
Using the System Setup Program and UEFI Boot Manager
69
book.book Page 70 Wednesday, January 20, 2010 10:20 AM
Option
USB Flash Drive
Emulation Type
(Auto default)
Boot Sequence Retry
(Disabled default)
Description
Determines the emulation type for a USB flash drive.
Hard disk allows the USB flash drive to act as a hard drive. Floppy allows the USB flash drive to act as a removable diskette drive. Auto automatically chooses an emulation type.
Auto automatically chooses the appropriate emulation type for the device, except for devices installed in the internal SD card slot. A device installed in the internal
SD card slot will automatically emulate a hard drive. If you install a device in this slot that is configured as a removable diskette drive, you must manually set the emulation type to Floppy.
If this field is enabled and the system has failed to boot, the system will reattempt to boot after 30 seconds.
Integrated Devices Screen
70
Option Description
Integrated SAS Controller
(Enabled default)
Enables or disables the integrated SAS controller.
User Accessible USB Ports
(All Ports On default)
Enables or disables the user accessible USB ports.
Options are All Ports On, Only Back Ports On, and All
Ports Off.
Enables or disables the internal USB port.
Internal USB Port
(On default)
Internal SD Card Port
Redundancy
(Disabled default)
Embedded NIC1 and
NIC2
(Enabled default)
Embedded NIC3 and
NIC4
(Enabled default)
Enables or disables the internal SD card port.
Enables or disables the internal dual SD module mirror mode.
Enables or disables the operating system interface of the embedded NICs. The NICs can also be accessed through the system's management controller.
Enables or disables the operating system interface of the embedded NICs. The NICs can also be accessed through the system's management controller.
Using the System Setup Program and UEFI Boot Manager
book.book Page 71 Wednesday, January 20, 2010 10:20 AM
Option
Embedded Gb NIC x
(NIC1 default: Enabled with PXE;
Other NICs: Enabled)
MAC Address
Capability Detected
OS Watchdog Timer
(Disabled default)
I/OAT DMA Engine
(Disabled default)
Embedded Video
Controller
(Enabled default)
SR-IOV Global Enable
(Enabled default)
Description
Enables or disables the integrated NIC. Options are
Enabled, Enabled with PXE, Enabled with iSCSI Boot, and Disabled. PXE support allows the system to boot from the network.
Displays the MAC address for the integrated 10/100/1000
NIC.
Displays the NIC features of the LOM NIC hardware key.
NOTE:
Some LOM features may require the installation of an additional driver.
Sets a timer to monitor the operating system for activity, and aids in recovery if the system stops responding.
When Enabled, the operating system is allowed to initialize the timer. When Disabled, the timer is not initialized.
NOTE:
This feature is usable only with operating systems that support WDAT implementations of the Advanced
Configuration and Power Interface (ACPI) 3.0b specification.
Enables or disables the I/O Acceleration Technology feature.
Enables or disables BIOS support for the integrated video controller.
NOTE:
This field can be disabled only if an add-in video card is present. If this field is disabled, remote access features such as virtual KVM are not available.
Enables or disables the BIOS configuration of Single
Root I/O Virtualization (SR-IOV) devices.
PCI IRQ Assignments Screen
Option
< PCIe device>
Description
Use the <+> and <-> keys to manually select an IRQ for a given device, or select Default to allow the BIOS to select an IRQ value at system startup.
Using the System Setup Program and UEFI Boot Manager
71
book.book Page 72 Wednesday, January 20, 2010 10:20 AM
Serial Communication Screen
Option Description
Serial Communication
(On without Console
Redirection default)
Serial Port Address
(Serial Device 1=COM1,
Serial Device2=COM2 default)
Selects whether the serial communication devices
(Serial Device 1 and Serial Device 2) are enabled in
BIOS. BIOS console redirection can also be enabled and the port address used can be specified.
Options are On without Console Redirection, On with
Console Redirection via COM1, On with Console
Redirection via COM2, and Off.
Sets the serial port addresses for the two serial devices.
NOTE:
Only Serial Device 2 can be used for Serial Over
LAN (SOL). To use console redirection by SOL, configure the same port address for console redirection and the serial device.
External Serial Connector Specifies whether Serial Device 1, Serial Device 2, or
Remote Access Device has access to the external serial connector.
NOTE:
Only Serial Device 2 can be used for Serial Over
LAN (SOL). To use console redirection by SOL, configure the same port address for console redirection and the serial device.
Failsafe Baud Rate
(115200 default)
Remote Terminal Type
(VT 100/VT220 default)
Redirection After Boot
(Enabled default)
Displays the failsafe baud rate used for console redirection. BIOS attempts to determine the baud rate automatically. This failsafe baud rate is used only if the attempt fails. This rate should not be adjusted.
Sets the remote console terminal type, either
VT100/VT220 or ANSI.
Enables or disables BIOS console redirection when the operating system is loaded.
72
Using the System Setup Program and UEFI Boot Manager
book.book Page 73 Wednesday, January 20, 2010 10:20 AM
Embedded Server Management Screen
Option
Front Panel LCD
Options
User-Defined LCD
String
Description
Options are User Defined String, Model Number, or
None.
If the LCD Home screen is set to an option other than these three choices, the option will be displayed as
"Advanced" in the BIOS. In this event, the option cannot be changed in the BIOS unless it is changed back to User
Defined String, Model Number, or None through another LCD configuration utility (such as the iDRAC
Configuration Utility or the LCD panel menu).
You can enter a name or other identifier for the system, to be displayed on the LCD module screen.
Power Management Screen
Option
Power Management
Description
Options are OS Control, Active Power Controller,
Custom, or Maximum Performance. For all but the
Custom setting, the BIOS pre-configures the power settings on this screen as follows:
• OS Control sets the CPU power to OS DBPM, the fan power to Minimum Power, and the memory power to
Maximum Performance. In this setting, all processor performance information is passed from the system
BIOS to the operating system for control. The operating system sets the processor performance based on processor utilization.
• Active Power Controller sets the CPU power to System
DBPM, the fan power to Minimum Power, and the memory power to Maximum Performance. The BIOS sets the processor performance based on processor utilization.
• Maximum Performance sets all fields to Maximum
Performance.
If you select Custom, you can configure each option independently.
Using the System Setup Program and UEFI Boot Manager
73
book.book Page 74 Wednesday, January 20, 2010 10:20 AM
Option
CPU Power and
Performance
Management
Fan Power and
Performance
Management
Memory Power and
Performance
Management
System Security Screen
Description
Options are OS DBPM, System DBPM, Maximum
Performance, or Minimum Power.
Options are Maximum Performance or Minimum Power.
Options are Maximum Performance, a specified frequency, or Minimum Power.
Option
System Password
Setup Password
Password Status
(Unlocked default)
Description
Displays the current status of the password security feature and allows a new system password assignment and verification.
NOTE:
See Using the "Using the System Password" on page 79 for more information.
Restricts access to the System Setup program by using a setup password.
NOTE:
See "Using the System Password" on page 79 for
more information.
When Setup Password is assigned and this field is
Locked, the system password cannot be changed or disabled at system start-up.
See "Using the System Password" on page 79 for more
information.
74
Using the System Setup Program and UEFI Boot Manager
book.book Page 75 Wednesday, January 20, 2010 10:20 AM
Option
TPM Security
(Off default)
TPM Activation
(No Change default)
TPM Clear
(No default)
Power Button
(Enabled default)
Description
Sets the reporting of the Trusted Platform Module
(TPM) in the system.
If Off, the presence of the TPM is not reported to the operating system.
If On with Pre-boot Measurements, the system reports the TPM to the operating system and stores the pre-boot measurements to the TPM during POST.
If On without Pre-boot Measurements, the system reports the TPM to the operating system and bypasses pre-boot measurements.
When set to Activate, the TPM is enabled to default settings. When set to Deactivate, the TPM is disabled.
The No Change state initiates no action. The operational state of the TPM remains unchanged (all user settings for the TPM are preserved).
NOTE:
This field is read-only when TPM Security is set to
Off.
CAUTION:
Clearing the TPM will lose all encryption keys in the TPM. This option prevents booting to the operating system and results in data loss if the encryption keys cannot be restored. Back up the TPM keys prior to enabling this option.
When set to Yes, all TPM contents are cleared.
NOTE:
This field is read-only when TPM Security is set to
Off.
If Enabled, the power button can turn the system's power off and on. On an ACPI-compliant operating system, the system performs an orderly shutdown before power is turned off.
When Disabled, the button can only turn on system power.
Using the System Setup Program and UEFI Boot Manager
75
book.book Page 76 Wednesday, January 20, 2010 10:20 AM
76
Option
NMI Button
(Disabled default)
Description
CAUTION:
Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing this button halts the operating system and displays a diagnostic screen.
Enables or disables the NMI feature.
AC Power Recovery
(Last default)
Determines how the system reacts when power is restored. If set to Last, the system returns to the last power state. On turns on the system after power is restored. Off allows the system to remain off after power is restored.
AC Power Recovery Delay Determines when the system restarts after power is restored. Options are Immediate, Random (a random value of 30 to 240 seconds), or a user-defined value of 30 to 240 seconds.
Exit Screen
Press <Esc> to exit the System Setup program; the Exit screen displays:
• Save Changes and Exit
• Discard Changes and Exit
• Return to Setup
Entering the UEFI Boot Manager
NOTE:
Operating systems must be 64-bit UEFI-compatible (for example, Microsoft
Windows Server
®
2008 x64 version) to be installed from the UEFI boot mode. DOS
® and 32-bit operating systems can only be installed from the BIOS boot mode.
NOTE:
The Boot Mode must be set to UEFI in the System Setup program to access the UEFI Boot Manager.
The UEFI Boot Manager enables you to:
• Add, delete, and arrange boot options
• Access the System Setup program and BIOS-level boot options without rebooting
1 Turn on or restart your system.
Using the System Setup Program and UEFI Boot Manager
book.book Page 77 Wednesday, January 20, 2010 10:20 AM
2 Press <F11> after you see the following message:
<F11> = UEFI Boot Manager
NOTE:
The system will not respond until the USB keyboard is active.
If your operating system begins to load before you press <F11>, allow the system to finish booting, and then restart your system and try again.
Using the UEFI Boot Manager Navigation Keys
Keys
Up arrow
Down arrow
Spacebar, <Enter>, <+>,
< – >
<Esc>
Action
Moves to and highlights the previous field.
Moves to and highlights the next field.
Cycles through the settings in a field.
<F1>
UEFI Boot Manager Screen
Refreshes the UEFI Boot Manager screen, or returns to the UEFI Boot Manager screen from the other program screens.
Displays the UEFI Boot Manager help file.
Option
Continue
< Boot options>
UEFI Boot Settings
Description
The system attempts to boot to devices starting with the first item in the boot order. If the boot attempt fails, the system will continue with the next item in the boot order until the boot is successful or no more boot options are found.
Displays the list of available boot options (marked with asterisks). Select the boot option you wish to use and press Enter.
NOTE:
If you hot-add a boot device, press <Esc> to refresh the list of boot options.
Enables you to add, delete, enable, or disable boot options; change boot order; or execute a one-time boot option.
Using the System Setup Program and UEFI Boot Manager
77
book.book Page 78 Wednesday, January 20, 2010 10:20 AM
Option
System Utilities
Description
Enables you to access the System Setup program,
System Services (Unified Server Configurator [USC]),
Diagnostics, and BIOS-level boot options.
UEFI Boot Settings Screen
Option Description
Add Boot Option
Delete Boot Option
Enable/Disable Boot
Option
Change Boot Order
Adds a new boot option.
Deletes an existing boot option.
Disables and enables a boot option in the boot option list.
Changes the order of the boot option list.
One-Time Boot From File Sets a one-time boot option not included in the boot option list.
System Utilities Screen
Option
System Setup
System Services
BIOS Boot Manager
Reboot System
Description
Accesses the System Setup program without rebooting.
Restarts the system and access the Lifecycle Controller, which allows you to run utilities such as system diagnostics.
Accesses the BIOS-level boot options list without rebooting. This option enables you to conveniently switch to BIOS boot mode if you need to boot to a device with a non-UEFI operating system, such as a bootable DOS media with diagnostics software.
Restarts the system.
78
Using the System Setup Program and UEFI Boot Manager
book.book Page 79 Wednesday, January 20, 2010 10:20 AM
System and Setup Password Features
NOTE:
For a forgotten password, see "Disabling a Forgotten Password" on page 201.
Your system is shipped without the system password feature enabled. Operate the system only with system password protection.
CAUTION:
The password features provide a basic level of security for the data on your system.
CAUTION:
Anyone can access the data stored on your system if the system is running and unattended.
Using the System Password
When a system password is assigned, the system prompts for the system password after the system starts and only those with the password have full use of the system.
Assigning a System Password
Before assigning a system password, enter the System Setup program and check the System Password option.
When a system password is assigned, System Password is Enabled. If
Password Status is Unlocked, you can change the system password. If Locked, you cannot change the system password. Disabling the password jumper on the system board sets System Password to Disabled, and you cannot change or enter a new system password.
When a system password is not assigned and the password jumper on the system board is in the enabled position, System Password is Not Enabled and
Password Status is Unlocked. To assign a system password:
1 Verify that Password Status is Unlocked.
2 Highlight the System Password option and press <Enter>.
3 Type your new system password.
You can use up to 32 characters in your password.
As you type, placeholders appear in the field.
Using the System Setup Program and UEFI Boot Manager
79
book.book Page 80 Wednesday, January 20, 2010 10:20 AM
80
The password assignment is not case-sensitive. Certain key combinations are invalid and if you enter one, the system beeps. To erase a character, press <Backspace> or the left-arrow key.
NOTE:
To escape from the field without assigning a system password, press
<Enter> to move to another field, or press <Esc> prior to completing step 5.
4 Press <Enter>.
5 To confirm your password, type it a second time and press <Enter>.
System Password changes to Enabled. Exit the System Setup program and begin using your system.
6 Either reboot the system now for the password protection to take effect or continue working.
NOTE:
Password protection does not take effect until the system reboots.
Using Your System Password to Secure Your System
NOTE:
password.
When Password Status is Unlocked, you have the option to leave the password security enabled or to disable password security.
To leave the password security enabled:
1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>.
2 Type your password and press <Enter>.
To disable the password security:
1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>.
2 Type your password and press <Ctrl><Enter>.
When Password Status is Locked, you must type the password and press
<Enter> when prompted at reboot.
If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an error message that the system has halted and will shut down.
Even after you shut down and restart the system, the error message continues to be displayed until the correct password is entered.
Using the System Setup Program and UEFI Boot Manager
book.book Page 81 Wednesday, January 20, 2010 10:20 AM
NOTE:
You can use the Password Status option in conjunction with the System
Password and Setup Password options to protect your system from unauthorized changes.
Deleting or Changing an Existing System Password
1 Enter the System Setup program and select the System Security.
2 Highlight Setup Password, press <Enter> to access the setup password window. Press <Enter> twice to clear the existing setup password.
The setting changes to Not Enabled.
3 If you want to assign a new setup password, perform the steps in "Assigning a Setup Password" on page 81.
Using the Setup Password
Assigning a Setup Password
You can assign a setup password only when the Setup Password is Not
Enabled. To assign a setup password, highlight the Setup Password option and press the <+> or <–> key. The system prompts you to enter and verify the password.
NOTE:
The setup password can be the same as the system password. If the two passwords are different, the setup password can be used as an alternate system password. The system password cannot be used in place of the setup password.
You can use up to 32 characters in your password.
As you type, placeholders appear in the field.
The password assignment is not case-sensitive. Certain key combinations are invalid and if you enter one, the system beeps. To erase a character, press
<Backspace> or the left-arrow key.
When you verify the password, the Setup Password changes to Enabled. The next time you enter the System Setup program, the system prompts you for the setup password.
A change to the Setup Password option becomes effective immediately
(restarting the system is not required).
Using the System Setup Program and UEFI Boot Manager
81
book.book Page 82 Wednesday, January 20, 2010 10:20 AM
Operating With a Setup Password Enabled
If Setup Password is Enabled, you must enter the correct setup password before modifying most of the System Setup options.
If you do not enter the correct password in three attempts, the system lets you view, but not modify, the System Setup screens. The following options are exceptions: If System Password is not Enabled and is not locked through the
Password Status option, you can assign a system password. You cannot disable or change an existing system password.
NOTE:
You can use the Password Status option in conjunction with the Setup
Password option to protect the system password from unauthorized changes.
Deleting or Changing an Existing Setup Password
1 Enter the System Setup program and select the System Security.
2 Highlight Setup Password, press <Enter> to access the setup password window. Press <Enter> twice to clear the existing setup password.
The setting changes to Not Enabled.
3 If you want to assign a new setup password, perform the steps in "Assigning a Setup Password" on page 81."
Embedded System Management
The Lifecycle Controller is an embedded utility that enables systems management tasks from an embedded environment throughout the server’s lifecycle.
Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.
NOTE:
Certain platform configurations may not support the full set of features provided by the Lifecycle Controller.
For more information about setting up the Lifecycle Controller, configuring hardware and firmware, and deploying the operating system, see the Lifecycle
Controller documentation on the Dell Support website at support.dell.com/manuals.
82
Using the System Setup Program and UEFI Boot Manager
book.book Page 83 Wednesday, January 20, 2010 10:20 AM
iDRAC Configuration Utility
The iDRAC Configuration Utility is a pre-boot configuration environment that allows you to view and set parameters for the iDRAC6 and for the managed server.
The iDRAC Configuration Utility provides the following features:
• Enables fault logging and SNMP alerting
• Provides access to system event log and sensor status
• Allows control of system functions including power on and off
• Functions independently of the system’s power state or the system’s operating system
• Provides text console redirection for system setup, text-based utilities, and operating system consoles
In addition, the iDRAC Configuration Utility enables you to:
• Configure, enable, or disable the iDRAC6 local area network through the dedicated iDRAC6 Enterprise card port or the embedded NIC1.
• Enable or disable IPMI over LAN
• Enable a LAN Platform Event Trap (PET) destination
• Attach or detach the Virtual Media devices
• Change the administrative user name and password and manage user privileges
• View System Event Log (SEL) messages or clear messages from the log
For additional information on using iDRAC6, see the documentation for iDRAC6 and systems management applications.
Entering the iDRAC Configuration Utility
1 Turn on or restart your system.
2 Press <Ctrl><E> when prompted during POST.
If your operating system begins to load before you press <Ctrl><E>, allow the system to finish booting, and then restart your system and try again.
Using the System Setup Program and UEFI Boot Manager
83
book.book Page 84 Wednesday, January 20, 2010 10:20 AM
84
Using the System Setup Program and UEFI Boot Manager
book.book Page 85 Wednesday, January 20, 2010 10:20 AM
Installing System Components
Recommended Tools
You may need the following items to perform the procedures in this section:
• Key to the system keylock
• #1 and #2 Phillips screwdrivers
• T8 and T10 Torx drivers
• Wrist grounding strap
Inside the System
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Installing System Components
85
book.book Page 86 Wednesday, January 20, 2010 10:20 AM
Figure 3-1.
Inside the System
4
5
3
1
2
6
7
9
11 10
1 optical drive (optional)
3 memory risers (up to 8)
5 power supply bays (4)
7 I/O card
9 cooling fan assembly
11 system identification panel
2 control panel display
4 cooling fans (up to 6)
6 PCIe expansion card
8 integrated storage controller card
10 hard drives (up to 16)
8
86
Installing System Components
book.book Page 87 Wednesday, January 20, 2010 10:20 AM
Front Bezel (Optional)
Removing the Front Bezel
1 Unlock the keylock at the left end of the bezel.
2 Lift up the release latch next to the keylock.
3 Rotate the left end of the bezel away from the front panel.
4 Unhook the right end of the bezel and pull the bezel away from the system.
Figure 3-2.
Removing and Installing the Front Bezel
1
2
3
1 release latch
3 front bezel
2 key lock
Installing the Front Bezel
1 Hook the right end of the bezel onto the chassis.
2 Fit the free end of the bezel onto the system and secure the bezel with the
Installing System Components
87
book.book Page 88 Wednesday, January 20, 2010 10:20 AM
System Identification Panel
Removing the System Identification Panel
1 If applicable, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 Pull the system identification panel out of its slot in the chassis, until it is
in the lock position. See Figure 3-3. The system identification panel is
located above the hard drive slot 8.
3 To release the left portion of the system identification panel, pull the panel to the right until it disengages from the slot in the chassis.
4 To release the right portion of the system identification panel, pull the panel to the left until it disengages from the slot in the chassis.
Figure 3-3.
Removing and Installing the System Identification Panel
1
1 system identification panel
88
Installing System Components
book.book Page 89 Wednesday, January 20, 2010 10:20 AM
Installing the System Identification Panel
1 Align the system identification panel with the slot on the chassis.
2 Slide the system identification panel into the chassis, until it locks into
3 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
Opening and Closing the System
WARNING:
Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by yourself.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Opening the System
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals.
2 Rotate the latch release lock counter clockwise to the unlocked position.
3 Lift up the latch and slide the cover back toward the back of the system.
4 Grasp the cover on both sides and lift the cover away from the system. See
Installing System Components
89
book.book Page 90 Wednesday, January 20, 2010 10:20 AM
Figure 3-4.
Opening and Closing the System
1 2
3
1 latch
3 cover
2 latch release lock
Closing the System
1 Place the cover onto the chassis and offset it slightly toward the back of the system, so that the chassis hooks on the back edge of the cover fit over the
corresponding slots on the back edge of the chassis. See Figure 3-4.
2 Slide the cover toward the front of the chassis till it snaps in position.
3 Push down the latch to lever the cover into the closed position.
4 Rotate the latch release lock in a clockwise direction to secure the cover.
90
Installing System Components
book.book Page 91 Wednesday, January 20, 2010 10:20 AM
System Memory
Your system supports DDR3 registered DIMMs (RDIMMs). Single-, dual-, and quad-rank DIMMs can be 1067 MHz or 1333 MHz.
The system contains eight memory risers split into four sets of two risers per
processor. Figure 3-5 shows the order of the memory risers in the system. Each
memory riser has eight DIMM sockets arranged into four channels. The first socket of each channel is marked with white release levers.
The maximum memory that is supported on your system varies according to the sizes of memory modules being used. Single-rank, dual-rank, and quadrank RDIMMs of sizes 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB are supported for a total of up to 1 TB.
NOTE:
Depending on the amount of memory installed, the system may take up to 3 minutes to display video on the screen.
Figure 3-5.
Memory Risers
Installing System Components
91
book.book Page 92 Wednesday, January 20, 2010 10:20 AM
General Memory Module Installation Guidelines
To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory.
NOTE:
Memory configurations that fail to observe these guidelines can prevent your system from starting and producing any video output.
• All populated memory risers must have identical configurations.
• The memory configuration for each processor must be identical for optimal performance.
• Memory modules of different sizes can be mixed (for example, 2 GB and
4 GB), but all populated channels must have identical configurations. The mixed memory configurations must be of the size N+/-1.
• The memory speed depends on the processor bin.
• If quad-rank memory modules are mixed with single- or dual-rank modules, the quad-rank modules must be installed in the sockets with the white release levers.
• If memory modules with different speeds are installed, they operate at the speed of the slowest installed memory module(s). The memory speeds are also dependent on the processor bin.
Two memory risers are allocated to each processor. The number of channels used and the allowable configurations depend on the memory mode selected.
The system supports memory mirroring if identical memory modules are installed in both the risers. Mirroring must be enabled in the System Setup program. In a mirrored configuration, the total available system memory is one-half of the total installed physical memory.
NOTE:
Memory sparing and mirroring are enabled only when memory configurations are greater than or equal to 64 GB.
92
Installing System Components
book.book Page 93 Wednesday, January 20, 2010 10:20 AM
Table 3-1.
Memory Configurations (Dual Processor)
CPU 1
Memory mode
Riser A (memory capacity in GB) Riser B (memory capacity in GB)
Total memory
(per processor)
/ total system memory
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
Power optimized 4 / 8
8 / 16
2
4
2
4
Not installed
Not installed
Performance optimized
Power and performance optimized
16 / 32
32 / 64
4 / 8
8 / 16
16 / 32
32 / 64
2 / 4
64 / 128
80 / 160
128 / 256
4
4 4 4 4 4 4 4 4 Not installed
1
1
2
4
1
4
1
1
2
4
1
4
1
2
4
4
1
2
4
Not installed
1
1
2
4
1
1
2
4
Not installed
1
2
4
1
2
4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
8 8 4 4 4 4 4 4 8 8 4 4 4 4 4 4
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Installing System Components
93
book.book Page 94 Wednesday, January 20, 2010 10:20 AM
Memory mode
CPU 2
Riser A (memory capacity in GB) Riser B (memory capacity in GB)
Total memory
(per processor)
/ total system memory
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
Power optimized 4 / 8
8 / 16
16 / 32
32 / 64
Performance optimized
4 / 8
8 / 16
16 / 32
32 / 64
Power and performance optimized
2 / 4
64 / 128
80 / 160
128 / 256
2
4
1
1
2
4
2
4
Not installed
Not installed
4 4 4 4 Not installed
4 4 4 4 4 4 4 4 Not installed
1
1
2
4
1
2
4
1
2
4
1
1
2
4
2
4
1
1 1
2
4
1
2
4
1 1 Not installed
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
8 8 4 4 4 4 4 4 8 8 4 4 4 4 4 4
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
94
Installing System Components
book.book Page 95 Wednesday, January 20, 2010 10:20 AM
Table 3-2.
Memory Configurations (Four Processors)
CPU 1
Memory mode
Power optimized
Total memory (per processor) / total system memory
Riser A (memory capacity in GB)
1
5
2
6
3
7
4
8
4 / 16
8 / 32
16 / 64
32 / 128
2
4
2
4
Riser B (memory capacity in GB)
1
5
2
Not installed
Not installed
4 4 4 4 Not installed
4 4 4 4 4 4 4 4 Not installed
6
3
7
4
8
Performance optimized
40 / 160
48 / 192
4 / 16
8 / 32
16 / 64
32 / 128
48 / 192
2 / 8
8
1
2
4
1
1
8 8 4 4 4 4 4 4 Not installed
8 8 8 8 4 4 4 4 Not installed
1
1
2
4
8
1
1
2
4
4
1
2
4
4
1
1
2
4
8
1
1
2
4
8
Not installed
1
2
4
4
1
2
4
4
Power and performance optimized
64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Expandability
256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
32 / 128
64 / 256
8
8
8
8 8 8
8
8
8
8 8 8
128 / 512 16 16 16 16 16 16 16 16
Installing System Components
95
book.book Page 96 Wednesday, January 20, 2010 10:20 AM
CPU 2
Memory mode
Power optimized
Total memory (per processor) / total system memory
Riser A (memory capacity in GB)
1
5
2
6
3
7
4
8
4 / 16
8 / 32
16 / 64
32 / 128
2
4
2
4
Riser B (memory capacity in GB)
1
5
2
Not installed
Not installed
4 4 4 4 Not installed
4 4 4 4 4 4 4 4 Not installed
6
3
7
4
8
Performance optimized
40 / 160
48 / 192
4 / 16
8 / 32
16 / 64
32 / 128
48 / 192
2 / 8
8
1
2
4
1
1
8 8 4 4 4 4 4 4 Not installed
8 8 8 8 4 4 4 4 Not installed
1
1
2
4
8
1
1
2
4
4
1
2
4
4
1
1
2
4
8
1
1
2
4
8
Not installed
1
2
4
4
1
2
4
4
Power and performance optimized
64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Expandability
256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
32 / 128
64 / 256
8
8
8
8 8 8
8
8
8
8 8 8
128 / 512 16 16 16 16 16 16 16 16
96
Installing System Components
book.book Page 97 Wednesday, January 20, 2010 10:20 AM
CPU 3
Memory mode
Power optimized
Total memory (per processor) / total system memory
Riser A (memory capacity in GB)
1
5
2
6
3
7
4
8
4 / 16
8 / 32
16 / 64
32 / 128
2
4
2
4
Riser B (memory capacity in GB)
1
5
2
Not installed
Not installed
4 4 4 4 Not installed
4 4 4 4 4 4 4 4 Not installed
6
3
7
4
8
Performance optimized
40 / 160
48 / 192
4 / 16
8 / 32
16 / 64
32 / 128
48 / 192
2 / 8
8
1
2
4
1
1
8 8 4 4 4 4 4 4 Not installed
8 8 8 8 4 4 4 4 Not installed
1
1
2
4
8
1
1
2
4
4
1
2
4
4
1
1
2
4
8
1
1
2
4
8
Not installed
1
2
4
4
1
2
4
4
Power and performance optimized
64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Expandability
256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
32 / 128
64 / 256
8
8
8
8 8 8
8
8
8
8 8 8
128 / 512 16 16 16 16 16 16 16 16
Installing System Components
97
book.book Page 98 Wednesday, January 20, 2010 10:20 AM
CPU 4
Memory mode
Power optimized
Total memory (per processor) / total system memory
Riser A (memory capacity in GB)
1
5
2
6
3
7
4
8
4 / 16
8 / 32
16 / 64
32 / 128
2
4
2
4
Riser B (memory capacity in GB)
1
5
2
Not installed
Not installed
4 4 4 4 Not installed
4 4 4 4 4 4 4 4 Not installed
6
3
7
4
8
Performance optimized
40 / 160
48 / 192
4 / 16
8 / 32
16 / 64
32 / 128
48 / 192
2 / 8
8
1
2
4
1
1
8 8 4 4 4 4 4 4 Not installed
8 8 8 8 4 4 4 4 Not installed
1
1
2
4
8
1
1
2
4
4
1
2
4
4
1
1
2
4
8
1
1
2
4
8
Not installed
1
2
4
4
1
2
4
4
Power and performance optimized
64 / 256 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
128 / 512 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Expandability
256 / 1024 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
32 / 128
64 / 256
8
8
8
8 8 8
8
8
8
8 8 8
128 / 512 16 16 16 16 16 16 16 16
98
Installing System Components
book.book Page 99 Wednesday, January 20, 2010 10:20 AM
Removing a Memory-Riser Blank
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Press the release tabs toward each other and lift the memory-riser blank out of the system.
Figure 3-6.
Removing and Installing a Memory-Riser Blank
2
1
1 release tabs (2) 2 memory-riser blank
Installing System Components
99
book.book Page 100 Wednesday, January 20, 2010 10:20 AM
100
Installing a Memory-Riser Blank
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Align the memory-riser blank with the slots on the memory-riser guide and the cooling fan assembly.
2 Insert the memory-riser blank firmly into the card guide until it is fully seated.
3 Close the system. See "Closing the System" on page 90.
4 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Removing a Memory Riser
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Press the release button on the memory riser to release the handle.
4 Grasp the handle and lift the memory riser out of the system.
CAUTION:
To maintain proper system cooling, all empty memory-riser slots must have memory-riser blanks installed.
5 Install a memory-riser blank. See "Installing a Memory-Riser Blank" on page 100.
6 Close the system. See "Closing the System" on page 90.
7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing System Components
book.book Page 101 Wednesday, January 20, 2010 10:20 AM
Figure 3-7.
Removing and Installing a Memory Riser
1
2
3
5
4
1 handle 2 memory
3 release button
5 memory-riser connector
4 card guide
Installing a Memory Riser
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the memory-riser blank. See "Removing a Memory-
CAUTION:
Before installing the memory riser, you must ensure that the memory module socket ejectors are in the locked position.
Installing System Components
101
book.book Page 102 Wednesday, January 20, 2010 10:20 AM
4 Align the memory riser with the slots on the memory-riser guide and the cooling fan assembly.
5 Insert the memory riser firmly into the card guide until it is fully seated.
6 Press down on the handle until it clicks into place.
NOTE:
You can only lower the handle after the memory riser is seated in the card guide. If the handle does not move down, verify that the memory riser is properly seated in the card guide.
7 Close the system. See "Closing the System" on page 90.
8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing Memory Modules
WARNING:
The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Remove the memory risers. See "Removing a Memory Riser" on page 100.
4 Pull the release tab and lift the memory module cover in the direction of the arrow.
102
Installing System Components
book.book Page 103 Wednesday, January 20, 2010 10:20 AM
Figure 3-8.
Removing and Installing the Memory Module Cover
1
2
1 release tab 2 memory module cover
CAUTION:
Handle each memory module only on either card edge, making sure not to touch the middle of the memory module.
5 Press the ejectors on the memory module socket down and out, as shown
Installing System Components
103
book.book Page 104 Wednesday, January 20, 2010 10:20 AM
Figure 3-9.
Installing and Removing a Memory Module
1
2
3
104
1 memory module
3 alignment key
2 memory module socket ejectors (2)
6 Align the memory module's edge connector with the alignment key of the memory module socket, and insert the memory module in the socket.
NOTE:
The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way.
7 Press down on the memory module with your thumbs to lock the memory module into the socket.
When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that have memory modules installed.
8 Repeat step 5 through step 7 of this procedure to install the remaining
memory modules. See Table 3-1 and Table 3-2.
9 Close the memory module cover.
10 Install the memory risers. See "Installing a Memory Riser" on page 101.
11 Close the system. See "Closing the System" on page 90.
Installing System Components
book.book Page 105 Wednesday, January 20, 2010 10:20 AM
12 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
13 Press <F2> to enter the System Setup program, and check the System
Memory setting on the main System Setup screen.
The system should have already changed the value to reflect the newly installed memory.
14 If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 2 through step 13 of this procedure to ensure that the memory modules are firmly seated in their sockets.
15 Run the system memory test in the system diagnostics. See "Running the
Embedded System Diagnostics" on page 194.
Removing Memory Modules
WARNING:
The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION:
To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Remove the memory risers. See "Removing a Memory Riser" on page 100.
4 Press the tabs in the direction of the arrows and lift the memory module cover.
CAUTION:
Handle each memory module only on either card edge, making sure not to touch the middle of the memory module.
Installing System Components
105
book.book Page 106 Wednesday, January 20, 2010 10:20 AM
5 Press down and out on the ejectors on each end of the socket until the
memory module pops out of the socket. See Figure 3-9.
6 Close the memory module cover.
7 Install the memory risers. See "Installing a Memory Riser" on page 101.
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system and peripherals to their power sources, and turn them on.
Removing the Memory-Riser Guide
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the memory-riser blanks. See "Removing a Memory-
4 Remove the memory risers. See "Removing a Memory Riser" on page 100.
5 Press the tabs in the direction of the arrows and lift the memory-riser guide out of the system.
Figure 3-10.
Removing or Installing the Memory-Riser Guide
1
2
106
1 memory-riser guide
Installing System Components
2 tabs (2)
book.book Page 107 Wednesday, January 20, 2010 10:20 AM
Installing the Memory-Riser Guide
1 Align the memory-riser guide with the slots on the chassis.
2 Lower the memory-riser guide into the system until the tabs click into place.
3 Install the memory risers. See "Installing a Memory Riser" on page 101.
4 If applicable, install the memory-riser blanks. See "Installing a Memory-
5 Close the system. See "Closing the System" on page 90.
6 Reconnect the system and peripherals to their power sources, and turn them on.
Hard Drives
All drives connect to the system board through the SAS/SATA backplane board. Hard drives are supplied in special hot-swappable drive carriers that fit in the hard-drive bays.
CAUTION:
Before attempting to remove or install a drive while the system is running, see the documentation for the SAS controller card to ensure that the host adapter is configured correctly to support hot-swap drive removal and insertion.
CAUTION:
Do not turn off or reboot your system while the drive is being formatted.
Doing so can cause a drive failure.
NOTE:
Use only drives that have been tested and approved for use with the
SAS/SATA backplane board.
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to format.
Installing System Components
107
book.book Page 108 Wednesday, January 20, 2010 10:20 AM
Removing a Hard-Drive Blank
CAUTION:
To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed.
1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
2 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
3 Press the release tab and slide the drive blank out until it is free of the drive
Figure 3-11.
Removing or Installing a Hard-Drive Blank
1
2
1 hard-drive blank 2 release tab
Installing a Hard-Drive Blank
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 Insert the drive blank into the drive bay until the blue release tab clicks into place.
3 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
108
Installing System Components
book.book Page 109 Wednesday, January 20, 2010 10:20 AM
Removing a Hard Drive
CAUTION:
Ensure that your operating system supports hot-swap drive installation. See the documentation supplied with the operating system.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 From the management software, prepare the drive for removal. Wait until the hard-drive indicators on the drive carrier signal that the drive can be removed safely. See your controller documentation for information about hot-swap drive removal.
If the drive has been online, the green activity/fault indicator flashes as the drive is powered down. When the drive indicators are off, the drive is ready for removal.
3 Open the drive carrier release handle to release the drive. See
4 Slide the hard drive out until it is free of the drive bay.
CAUTION:
To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed.
5 Insert a drive blank in the empty drive bay. See "Installing a Hard-Drive
6 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
Installing System Components
109
book.book Page 110 Wednesday, January 20, 2010 10:20 AM
Figure 3-12.
Removing and Installing a Hard Drive
1
2
1 release button 2 hard drive carrier handle
Installing a Hard Drive
CAUTION:
Use only hard drives that have been tested and approved for use with the SAS/SATA backplane.
CAUTION:
When installing a hard drive, ensure that the adjacent drives are fully installed. Inserting a hard-drive carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable.
CAUTION:
Ensure that your operating system supports hot-swap drive installation. See the documentation supplied with your operating system.
CAUTION:
Combining SATA and SAS hard drives in the same system configuration is not supported.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 If a drive blank is present in the bay, remove it. See "Removing a Hard-
110
Installing System Components
book.book Page 111 Wednesday, January 20, 2010 10:20 AM
NOTE:
If you are upgrading your system to a 16 –hard-drive configuration, turn off the system and remove all the chassis blanks. To remove the chassis blank, press down and push the blue release tab toward the front of the system. See
3 Press the button on the front of the drive carrier and open the handle.
4 Insert the hard-drive carrier into the drive bay until the carrier contacts the backplane.
5 Close the handle to lock the drive in place.
Figure 3-13.
Removing a Chassis Blank
2
1
1 chassis blank 2 release tab
Installing System Components
111
book.book Page 112 Wednesday, January 20, 2010 10:20 AM
Removing a Hard Drive From a Hard-Drive Carrier
Remove the screws from the slide rails on the hard-drive carrier and separate
the hard drive from the carrier. See Figure 3-14.
Figure 3-14.
Removing or Installing a Hot-Swap Hard Drive Into a Drive Carrier
4
1
2
1 screws (4)
3 SAS/SATA screw hole
2 drive carrier
4 hard drive
3
112
Installing System Components
book.book Page 113 Wednesday, January 20, 2010 10:20 AM
Installing a Hard Drive Into a Drive Carrier
1 Insert the hard drive into the hard-drive carrier with the connector end
of the drive at the rear. See Figure 3-14.
2 Align the screw holes on the hard drive with the back set of holes on the hard drive carrier.
When aligned correctly, the back of the hard drive will be flush with the back of the hard-drive carrier.
3 Attach the four screws to secure the hard drive to the hard-drive carrier.
Optical Drive
An optional DVD +/-RW optical drive slides into the front panel and connects to the SATA controller on the system board.
NOTE:
DVD devices are data only.
Removing an Optical Drive
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 If applicable, remove the memory risers H, G, and D. See "Removing a
Memory Riser" on page 100. For the location of memory risers H, G, and D
on the system, see Figure 3-5.
5 Disconnect the power/data cable from the back of the drive.
Note the routing of the power/data cable on the side on the system as you remove them from the system board and drive. You must route these cables properly when you replace them to prevent them from being pinched or crimped.
Installing System Components
113
book.book Page 114 Wednesday, January 20, 2010 10:20 AM
6 To remove the drive, press down and push the blue release tab toward the
front of the system. See Figure 3-15.
7 Slide the optical drive out of the system until it is free of the drive bay.
8 If you are not adding a new optical drive, install the optical drive insert.
9 If applicable, install the memory risers H, G, and D. See "Installing a
10 Close the system. See "Closing the System" on page 90.
11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
12 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
Figure 3-15.
Removing the Optical Drive
2
3
1
1 optical drive
3 release tab
114
Installing System Components
2 power/data cable
book.book Page 115 Wednesday, January 20, 2010 10:20 AM
Installing an Optical Drive
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 If applicable, remove the memory risers H, G, and D. See "Removing a
5 Slide the optical drive into the optical drive bay until the blue release tab
snaps into place. See Figure 3-15.
6 Connect the power/data cable to the back of the drive.
You must route the cable properly on the side of system to prevent it from being pinched or crimped.
7 If not already done, connect the power cable to SATA_PWR and the
interface cable to SATA_A connector on the system board. See Figure 6-1.
8 If applicable, install the memory risers H, G, and D. See "Installing a
Memory Riser" on page 101. For the location of memory risers H, G, and D
on the system, see Figure 3-5.
9 Close the system. See "Closing the System" on page 90.
10 Reconnect the system and peripherals to their electrical outlets.
11 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
Installing System Components
115
book.book Page 116 Wednesday, January 20, 2010 10:20 AM
Cooling Fans
Your system contains six single-rotor hot-swappable fans to provide cooling for the processors, expansion cards, and memory modules.
NOTE:
In the event of a problem with a particular fan, the fan number is referenced by the system’s management software, allowing you to easily identify and replace the proper fan by noting the fan numbers on the fan assembly.
Removing a Cooling Fan
WARNING:
The cooling fan can continue to spin for some time after it has been powered down. Allow time for the fan to stop spinning before removing it from the system.
WARNING:
Do not attempt to operate the system without the cooling fans or the cover.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE:
The procedure for removing each individual fan module is the same.
1 Open the system. See "Opening the System" on page 89.
2 Press the release tabs toward each other and lift the fan out of the fan
116
Installing System Components
book.book Page 117 Wednesday, January 20, 2010 10:20 AM
Figure 3-16.
Removing and Installing a Cooling Fan
1
2
3
1 release tab (2)
3 cooling fan assembly
2 cooling fan
Installing a Cooling Fan
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Align the connector on the fan with the connector on the system board.
2 Lower the fan into the fan assembly until the release tabs snap into place.
3 Close the system. See "Closing the System" on page 90.
Installing System Components
117
book.book Page 118 Wednesday, January 20, 2010 10:20 AM
Removing the Cooling Fan Assembly
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the memory-riser blanks. See "Removing a Memory-
4 Remove the memory risers. See "Removing a Memory Riser" on page 100.
5 Remove the fans from the cooling fan assembly. See "Removing a Cooling
6 Pull the blue release tabs in the direction of the arrows to release the
handles on the cooling fan assembly. See Figure 3-17.
7 Grasp the handles and lift the cooling fan assembly out of the system. See
118
Installing System Components
book.book Page 119 Wednesday, January 20, 2010 10:20 AM
Figure 3-17.
Removing and Installing the Fan Assembly
1
2
3
1 handles (2)
3 release tabs (2)
2 cooling fan assembly
Installing System Components
119
book.book Page 120 Wednesday, January 20, 2010 10:20 AM
Installing the Cooling Fan Assembly
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Align the tabs on the cooling fan assembly with the slots on the system.
NOTE:
You must also ensure that the pins on the bottom of the cooling fan assembly are aligned with the holes on the system board.
2 Insert the cooling fan assembly into the system and lower the handles to lock it in place.
3 Install the cooling fans. See "Installing the Cooling Fan Assembly" on page 120.
4 Install the memory risers. See "Installing a Memory Riser" on page 101.
5 If applicable, install the memory-riser blanks. See "Installing a Memory-
6 Close the system. See "Closing the System" on page 90.
7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Internal USB Memory Key
An optional USB memory key installed inside your system can be used as a boot device, security key, or mass storage device. The USB connector must be enabled by the Internal USB Port option in the Integrated Devices screen of the System Setup program.
To boot from the USB memory key, configure the USB memory key with a boot image and then specify the USB memory key in the boot sequence in the
System Setup program.
120
Installing System Components
book.book Page 121 Wednesday, January 20, 2010 10:20 AM
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Locate the USB connector on the system board.
4 Insert the USB memory key into the USB connector. See Figure 3-18.
5 Close the system. See "Closing the System" on page 90.
6 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
7 Enter the System Setup program and verify that the USB key has been
detected by the system. See "Using the System Setup Program and UEFI
Installing System Components
121
book.book Page 122 Wednesday, January 20, 2010 10:20 AM
Figure 3-18.
Removing and Installing a USB Memory Key
1
2
1 USB memory key 2 USB memory key connector
122
Installing System Components
book.book Page 123 Wednesday, January 20, 2010 10:20 AM
Integrated NIC Hardware Key
TCP/IP Offload Engine (TOE) and iSCSI are enabled by default on the system. The integrated NIC hardware key is reserved for future use.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE:
TOE operating system support and the Microsoft
® scalable network pack are required for TOE functionality.
1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Locate the iSCSI_KEY connector on the system board. See Figure 6-1.
4 Insert the NIC hardware key into the connector onto the board. See
Installing System Components
123
book.book Page 124 Wednesday, January 20, 2010 10:20 AM
Figure 3-19.
Removing or Installing a NIC Hardware Key
1
2
124
1 NIC hardware key 2 iSCSI_KEY connector
5 Close the system. See "Closing the System" on page 90.
6 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Expansion Cards and Expansion-Card Riser
Expansion Card Installation Guidelines
Your system supports one Generation 1 PCIe expansion card and up to six
Generation 2 PCIe expansion cards.
• The expansion slot supports full-height, half-length cards.
• The expansion-card slot is not hot-swappable.
• PCI Express Generation 2 slots support both PCI Express Generation 1 and PCI Express Generation 2 cards. However, using a PCI Express
Generation 2 card on an PCI Express Generation 1 slot may impact performance of the card.
Installing System Components
book.book Page 125 Wednesday, January 20, 2010 10:20 AM
• PCI Express Generation 1 is supported on slot 5 and Generation 2 expansion cards are supported in the slots 1, 2, 3, 4, 6, and 7.
• Slot 7 can be expanded to four additional PCIe x4 Generation 2 low profile slots using an optional PCIe expansion riser.
• Table 3-3 provides a guide for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All other expansion cards should be installed in card priority and slot priority order.
Table 3-3.
Expansion-Card Installation Order
Card
Priority
1
2
3
4
5
6
7
8
9
10
Card Type
PERC H800
6 Gbps SAS HBA
SAS 5/E Adapter
10 Gb NICs
8G Fiber Channel
(single port)
8G Fiber Channel
(dual port)
4G Fibre Channel
SCSI HBA
1 Gb NICs
(Generation 1 adapters)
1 Gb NICs
(Generation 2 adapters)
Slot Priority
Without a PCIe
Riser
Slot Priority With a PCIe Riser
2, 3, 4, 6, 1 2, 3, 4, 6,
7, 1
2, 3, 4, 6,
7, 1
2, 3, 4, 6,
7
2, 3, 4, 6,
7
1, 2, 3, 4,
6, 7
2, 3, 4, 6,
7
5, 1, 2, 3,
4, 6, 7
5, 1, 2, 3,
4, 6, 7
5, 1, 2, 3,
4, 6, 7, 1
5, 1, 2, 3,
4, 6, 7, 1
2, 3, 4, 6, 1
2, 3, 4, 6
2, 3, 4, 6
1, 7, 8, 9, 10,
2, 3, 4, 6
2, 3, 4, 6
5, 1, 7, 8, 9,
10, 2, 3, 4, 6
5, 1, 7, 8, 9,
10, 2, 3, 4, 6
5, 1, 7, 8, 9, 10,
2, 3, 4, 6
1, 7, 8, 9, 10, 5,
2, 3, 4, 6
Max
Allowed
2
2
2
2
4
2
4–6
2
10
10
Installing System Components
125
book.book Page 126 Wednesday, January 20, 2010 10:20 AM
Installing an Expansion Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 Open the expansion-card latch and remove the filler bracket. See
5 Holding the card by its edges, position the card so that the card-edge connector aligns with the expansion-card connector.
6 Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.
7 Close the expansion-card latch. See Figure 3-20.
8 If applicable, install the screw to secure the expansion card to the system.
126
Installing System Components
book.book Page 127 Wednesday, January 20, 2010 10:20 AM
Figure 3-20.
Installing or Removing an Expansion Card
1 2
3
4
1 expansion-card latch
3 expansion card
2 screw
4 expansion-card connector
Installing System Components
127
book.book Page 128 Wednesday, January 20, 2010 10:20 AM
9 If applicable, connect any cables to the expansion card.
10 Close the system. See "Closing the System" on page 90.
11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
12 Install any device drivers required for the card as described in the documentation for the card.
Removing an Expansion Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, disconnect all the cables from the card.
4 If applicable, remove the screw that secures the expansion card to the system.
5 To remove the expansion card, open the expansion-card latch.
6 Grasp the expansion card by its edges, and carefully remove it from the expansion-card connector.
7 If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.
NOTE:
You must install a filler bracket over an empty expansion slot to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
128
Installing System Components
book.book Page 129 Wednesday, January 20, 2010 10:20 AM
Installing an Expansion-Card Riser
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Unpack the expansion-card riser and prepare it for installation.
2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 Pull the latch toward the front of the system and lift the expansion-card
panel out of the system. See Figure 3-21.
5 To add expansion cards on the expansion-card riser, press the tabs toward
each other and open the expansion-card latch. See Figure 3-22.
6 Holding the card by its edges, position the card so that the card-edge connector aligns with the connector on the expansion-card riser.
7 Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.
8 Close the expansion-card latch.
9 Align the expansion-card riser with the slots on the chassis.
10 Lower the expansion-card riser until the riser is fully seated in the
connector and the latch clicks into place. See Figure 3-23.
11 Close the system. See "Closing the System" on page 90.
12 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
13 Install any device drivers required for the card as described in the documentation for the card.
Installing System Components
129
book.book Page 130 Wednesday, January 20, 2010 10:20 AM
Figure 3-21.
Removing and Installing the Panel
1
2
1 latch 2 panel
130
Installing System Components
book.book Page 131 Wednesday, January 20, 2010 10:20 AM
Figure 3-22.
Removing and Installing an Expansion Card in an Expansion-Card Riser
3
4
2
1
1 expansion-card riser
3 tabs (2)
2 expansion card
4 expansion-card latch
Installing System Components
131
book.book Page 132 Wednesday, January 20, 2010 10:20 AM
Figure 3-23.
Removing and Installing an Expansion-Card Riser
1
2
3
1 release tabs (2)
3 expansion-card riser connector
2 expansion-card riser
132
Installing System Components
book.book Page 133 Wednesday, January 20, 2010 10:20 AM
Removing an Expansion-Card Riser
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 To remove the expansion-card riser, press the release tabs toward each
other and lift the expansion-card riser out of the system. See Figure 3-23.
4 Press the tabs toward each other and open the expansion-card latch. See
5 Grasp the expansion-card by its edges, and carefully remove it from the expansion-card connector on the riser.
6 If you are removing the expansion-card riser permanently, install the panel
in the system. See Figure 3-21.
NOTE:
You must install the panel over an empty expansion slot to maintain
Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.
7 Close the system. See "Closing the System" on page 90.
8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing System Components
133
book.book Page 134 Wednesday, January 20, 2010 10:20 AM
I/O Card
Removing the I/O Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 If applicable, disconnect the external cables connected to the I/O card.
3 Open the system. See "Opening the System" on page 89.
4 Grasp the card by its edges and lift the card to remove it from the I/O card
connector. See Figure 3-1 for the location of the I/O card in the system.
5 If applicable, remove the internal dual SD module. See "Removing the
Internal Dual SD Module" on page 139.
134
Installing System Components
book.book Page 135 Wednesday, January 20, 2010 10:20 AM
Figure 3-24.
Removing and Installing the I/O Card
1
2
1 I/O card 2 I/O card connector
Installing the I/O Card
2 If applicable, install the internal dual SD module. See "Installing the
Internal Dual SD Module" on page 141.
3 Holding the card by its edges, position the card so that the card-edge connector aligns with the I/O card connector.
4 Insert the card-edge connector firmly into the I/O card connector until the card is fully seated.
Installing System Components
135
book.book Page 136 Wednesday, January 20, 2010 10:20 AM
5 Close the system. See "Closing the System" on page 90.
6 If applicable, reconnect the external cables to the I/O card.
7 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
iDRAC6 Enterprise Card (Optional)
Installing an iDRAC6 Enterprise Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Remove the I/O card. See "Removing the I/O Card" on page 134.
4 Remove the plastic filler plug for the iDRAC6 Enterprise port from the
I/O card.
5 Align the front edge of the card with the two front plastic retention standoffs next to the iDRAC6 connector on the system board, and lower
the card into place. See Figure 3-25.
When the front of the card is fully seated, the plastic standoffs snap over the edge of the card.
136
Installing System Components
book.book Page 137 Wednesday, January 20, 2010 10:20 AM
Figure 3-25.
Installing or Removing an iDRAC6 Enterprise Card (Optional)
2
1
3
4
5
1 iDRAC6 Enterprise card
3 retention standoff tabs (2)
5 iDRAC6 Enterprise card connector
2 VFlash media slot
4 retention standoff posts (2)
6 Install the I/O card. See "Installing the I/O Card" on page 135.
7 Close the system. See "Closing the System" on page 90.
8 Reconnect the system and peripherals to their power sources, and turn them on.
Installing System Components
137
book.book Page 138 Wednesday, January 20, 2010 10:20 AM
Removing an iDRAC6 Enterprise Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 If applicable, disconnect the Ethernet cable from the iDRAC6 Enterprise
Card connector on the system back panel. See Figure 1-3.
3 Open the system. See "Opening the System" on page 89.
4 Remove the I/O card. See "Removing the I/O Card" on page 134.
5 If applicable, remove the VFlash media card from the iDRAC6 Enterprise
Card. See "Removing a VFlash Media Card" on page 139.
6 Pull back slightly on the two tabs at the front edge of the card and gently lift the front edge of the card off of the retention standoffs.
As the card releases from the standoffs, the connector under the card disengages from the system board connector.
7 Install the plastic filler plug over the port on the I/O card.
8 Install the I/O card. See "Installing the I/O Card" on page 135.
9 Close the system. See "Closing the System" on page 90.
10 Reconnect the system and peripherals to their power sources, and turn them on.
138
Installing System Components
book.book Page 139 Wednesday, January 20, 2010 10:20 AM
VFlash Media (Optional)
The VFlash media card is a Secure Digital (SD) card that plugs into the optional iDRAC6 Enterprise card at the back corner of the system.
Installing a VFlash Media Card
1 Locate the VFlash media slot at the back corner of the system.
2 With the label side facing up, insert the contact-pin end of the SD card into the card slot on the module.
NOTE:
The slot is keyed to ensure correct insertion of the card.
3 Press inward on the card to lock it into the slot.
Removing a VFlash Media Card
To remove the VFlash media, push inward on the card to release it, and pull the card from the card slot.
Internal Dual SD Module (Optional)
NOTE:
When the Redundancy option is set to Mirror Mode in the Integrated
Devices screen of the system setup, the information is replicated from one SD card to another.
Removing the Internal Dual SD Module
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the SD card(s). See "Removing an Internal SD Card" on page 142.
4 Remove the I/O card. See "Removing the I/O Card" on page 134.
Installing System Components
139
book.book Page 140 Wednesday, January 20, 2010 10:20 AM
5 Disconnect the SD module cable.
6 Pull back slightly on the tabs at the edge of the card and gently lift the edge of the card off of the retention standoffs.
7 Install the I/O card. See "Installing the I/O Card" on page 135.
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system and peripherals to their power sources, and turn them on.
Figure 3-26.
Removing and Installing the Internal Dual SD Module
3
4
2
1
1 retention standoff posts (3)
3 SD module cable
2 retention standoff tabs (3)
4 dual SD module
140
Installing System Components
book.book Page 141 Wednesday, January 20, 2010 10:20 AM
Installing the Internal Dual SD Module
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Remove the I/O card. See "Removing the I/O Card" on page 134.
4 Align the card with the plastic retention standoffs on the I/O card, and
lower the card into place. See Figure 3-25.
When the front of the card is fully seated, the plastic standoffs snap over the edge of the card.
5 Connect the SD module cable to the connector on the I/O card.
6 Install the I/O card. See "Installing the I/O Card" on page 135.
7 If applicable, install the SD card(s). See "Installing an Internal SD Card" on page 142.
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system and peripherals to their power sources, and turn them on.
Installing System Components
141
book.book Page 142 Wednesday, January 20, 2010 10:20 AM
Internal SD Card (Optional)
Installing an Internal SD Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE:
To use an SD card with your system, ensure that the internal SD card port is
enabled in the System Setup program. See "Using the System Setup Program and
UEFI Boot Manager" on page 63.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Locate the SD card connector on the internal dual SD module. With the label side facing up, insert the contact-pin end of the card into the slot.
NOTE:
The slot is keyed to ensure correct insertion of the card.
4 Press the card into the card slot to lock it into place.
5 Close the system. See "Closing the System" on page 90.
6 Reconnect the system and peripherals to their power sources, and turn them on.
Removing an Internal SD Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
142
Installing System Components
book.book Page 143 Wednesday, January 20, 2010 10:20 AM
3 Locate the SD card slot on the internal dual SD module and press inward on the card to release it from the slot and remove the card.
4 Close the system. See "Closing the System" on page 90.
5 Reconnect the system and peripherals to their power sources, and turn them on.
Integrated Storage Controller Card
Your system includes a dedicated expansion-card slot on the system board for an integrated controller card that provides the integrated storage subsystem for your system’s internal hard drives. The controller supports SAS and SATA hard drives and also enables you to set up the hard drives in RAID configurations as supported by the version of the storage controller included with your system.
Removing the Integrated Storage Controller Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Remove the I/O card. See "Removing the I/O Card" on page 134.
4 Disconnect the cables connected to the storage controller card. See
Figure 3-1 for the location of the integrated storage controller card in
the system.
5 Grasp the card by its edges and lift the card to remove it from the connector on the system board.
6 Install the I/O card. See "Installing the I/O Card" on page 135
7 Close the system. See "Closing the System" on page 90.
8 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing System Components
143
book.book Page 144 Wednesday, January 20, 2010 10:20 AM
Figure 3-27.
Installing the Integrated Storage Controller Card
1
2
3
5
4
1 battery cable
3 integrated storage controller card
5 clip
2 SAS data cables (2)
4 integrated storage controller card connector
144
Installing System Components
book.book Page 145 Wednesday, January 20, 2010 10:20 AM
Installing the Integrated Storage Controller Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Remove the I/O card. See "Removing the I/O Card" on page 134.
4 Hold the card by its edges and insert the card-edge connector firmly into the connector until the card is fully seated and the plastic card guides fit over the edges of the card.
5 Connect the SAS data cable connector to the integrated storage controller
NOTE:
You must ensure that you connect the cable according to the connector labels on the cable. The cable does not function properly if reversed.
6 Route the SAS data cable through the clip on the card and through the channel on the inner side of the chassis.
7 Attach the connector labeled "SAS A" to connector SAS A on the backplane, and attach the connector labeled "SAS B" to connector SAS B
on the backplane. See Figure 3-27.
8 Install the I/O card. See "Installing the I/O Card" on page 135.
9 Close the system. See "Closing the System" on page 90.
10 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing System Components
145
book.book Page 146 Wednesday, January 20, 2010 10:20 AM
RAID Battery
The information in this section applies only to systems with the optional
PERC controller card.
Removing a RAID Battery
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the memory-riser blanks. See "Removing a Memory-
4 Remove the memory risers. See "Removing a Memory Riser" on page 100.
5 Remove the memory-riser guide. See "Removing the Memory-Riser Guide" on page 106.
6 Pull back gently on the right edge of the battery carrier and lift the RAID
battery from the battery carrier. See Figure 3-28.
7 Disconnect the RAID battery cable from the RAID battery.
146
Installing System Components
book.book Page 147 Wednesday, January 20, 2010 10:20 AM
Figure 3-28.
Removing or Installing the RAID Battery
2
3
1
1 battery carrier
3 RAID battery
2 RAID battery cable
Installing the RAID Battery
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Connect the battery cable to the integrated storage controller card.
2 Route the battery cable/SAS A cable along the chassis wall.
3 Connect the battery cable to the RAID battery.
Installing System Components
147
book.book Page 148 Wednesday, January 20, 2010 10:20 AM
148
4 Insert the RAID battery into the battery carrier. See Figure 3-28.
NOTE:
While installing the RAID battery into the battery carrier, you must ensure that the RAID battery cable faces the chassis wall.
5 Install the memory-riser guide. See "Installing the Memory-Riser Guide" on page 107.
6 Install the memory risers. See "Installing a Memory Riser" on page 101.
7 If applicable, install the memory-riser blanks. See "Installing a Memory-
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Processors
Removing a Processor
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Prior to upgrading your system, download the latest system BIOS version from support.dell.com and follow the instructions included in the compressed download file to install the update on your system.
2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. When disconnected from AC power, press and hold the power button for three seconds to fully drain the system of stored power prior to removing the cover.
NOTE:
It is recommended that you always use a static mat and static strap while working on components in the interior of the system.
3 Open the system. See "Opening the System" on page 89.
4 If applicable, remove the memory-riser blanks. See "Removing a Memory-
5 Remove the memory risers. See "Removing a Memory Riser" on page 100.
Installing System Components
book.book Page 149 Wednesday, January 20, 2010 10:20 AM
6 Remove the cooling fan assembly. See "Removing the Cooling Fan
WARNING:
The heat sink and processor are hot to touch for some time after the system has been powered down. Allow the heat sink and processor to cool before handling them.
CAUTION:
Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions.
7 Release one of the heat-sink release levers. See Figure 3-29.
8 Wait 30 seconds for the heat sink to loosen from the processor.
9 Release the other heat-sink release lever.
10 Gently lift the heat sink off of the processor and set the heat sink aside upside down (thermal grease side facing up).
Installing System Components
149
book.book Page 150 Wednesday, January 20, 2010 10:20 AM
Figure 3-29.
Installing and Removing the Heat Sink
2
1
1 release levers (2) 2 heat sink
CAUTION:
The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped.
11 Position your thumb firmly over the processor socket-release lever and release the lever from the locked position by pushing down and pulling out from under the tab. Rotate the lever 90 degrees upward until the processor
is released from the socket. See Figure 3-29.
12 Use the tab on the processor shield to rotate shield upward and out of the
150
Installing System Components
book.book Page 151 Wednesday, January 20, 2010 10:20 AM
CAUTION:
Be careful not to bend any of the pins on the ZIF socket when removing the processor. Bending the pins can permanently damage the system board.
13 Carefully lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor.
After removing the processor, place it in an antistatic container for reuse, return, or temporary storage. Do not touch the bottom of the processor.
Touch only the side edges of the processor.
Figure 3-30.
Removing and Installing a Processor
4
5
2
3
1
6
Installing System Components
151
book.book Page 152 Wednesday, January 20, 2010 10:20 AM
1 socket-release lever
3 pin 1 indicators (2)
5 notch in processor (2)
2 processor shield
4 processor
6 ZIF socket
Installing a Processor
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE:
In a dual-processor configuration, CPU 1 and CPU 2 sockets must be used.
1 If you are adding a processor for the first time, remove the socket cover.
Figure 3-31.
Removing the Processor Socket Cover
1
2
152
1 processor cover
Installing System Components
2 processor socket
book.book Page 153 Wednesday, January 20, 2010 10:20 AM
2 Remove the processor from the packing material by the processor’s edges only. Do not touch the bottom of the processor. Handle the processor carefully with your fingers on the side edges. Place your hand beneath the processor when you are moving it to the system.
3 Locate the pin 1 indicator on the system board socket.
4 Locate the pin 1 indicator on the top of the processor. The pin 1 indicator
is shown as a triangle on the top of the processor. See Figure 3-30.
CAUTION:
Positioning the processor incorrectly can permanently damage the system board or the processor. Be careful not to bend the pins in the socket.
5 Place the processor over the socket with each pin 1 aligned and level. See
6 Align the notches in the processor with the socket keys on the ZIF
7 Install the processor in the socket. Keep the processor level (see
Figure 3-30) and insert it straight down into the socket. Allow the
processor to float on the pins, allowing the processor shield to hold it in place.
8 Verify that the processor is properly aligned and seated.
9 Close the processor shield. See Figure 3-30.
10 Rotate the socket-release lever down until it snaps into place. See
11 Using a clean lint-free cloth, remove the thermal grease from the heat sink.
CAUTION:
Applying too much thermal grease can result in excess grease coming in contact with and contaminating the processor socket.
12 Open the grease applicator included with your processor kit and apply all of the thermal grease in the applicator to the center of the topside of the new processor.
13 Place the heat sink on the processor. See Figure 3-29.
14 Close the heat-sink release levers. See Figure 3-29.
15 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.
16 Install the memory risers. See "Installing a Memory Riser" on page 101.
Installing System Components
153
book.book Page 154 Wednesday, January 20, 2010 10:20 AM
17 If applicable, install the memory-riser blanks. See "Installing a Memory-
18 Close the system. See "Closing the System" on page 90.
19 Reconnect your system and peripherals to their electrical outlets, and turn on the system.
Power Supplies
Your system supports the following power supply modules:
• 1100 W (high output power supply)
• 750 W (energy smart power supply)
When a 10 Gb I/O card is installed, the system must have at least two power supplies connected to an A/C power supply. The system requires two power supplies to provide standby power to the system. With a 1 GbE I/O card, only
one PSU is required to provide standby power to the system. Table 3-4 and
Table 3-5 lists the power supply redundancy modes for a 10 Gb I/O card and a
1 GbE I/O card.
Table 3-4.
Power Supply Redundancy Modes With a 10 Gb I/O Card
Number of Power Supplies Redundancy Mode
1 1+0*
2
3
4
2+0
2+0
2+2
* indicates that the system operates with a limited load.
System Configuration
Non-redundant configuration with inactive
SFP+ ports
Non-redundant configuration
Non-redundant configuration
Redundant configuration
154
Installing System Components
book.book Page 155 Wednesday, January 20, 2010 10:20 AM
Table 3-5.
Power Supply Redundancy Modes With a 1 GbE I/O Card
3
4
2
2
Number of Power Supplies Redundancy Mode
1 1+0*
1+1*
2+0
2+1
2+2
*indicates that the system operates with a limited load.
System Configuration
Non-redundant configuration
Redundant configuration
Non-redundant configuration
Redundant configuration
Redundant configuration
Removing a Power Supply
CAUTION:
The system requires one power supply to operate the system normally.
On power-redundant systems, remove and replace only one power supply at a time in a system that is powered on.
1 Disconnect the power cable from the power source.
2 Disconnect the power cable from the power supply and remove the Velcro straps that bundle and secure the system cables.
NOTE:
You may have to unlatch and lift the optional cable management arm if it interferes with power-supply removal. For information about the cable management arm, see the system’s rack documentation.
3 Pull the power supply straight out to release it from the power distribution board and clear the chassis.
If you are permanently removing the power supply, you must install a
power supply blank to ensure proper system cooling. See "Installing the
Power Supply Blank" on page 157.
Installing System Components
155
book.book Page 156 Wednesday, January 20, 2010 10:20 AM
Figure 3-32.
Removing and Installing a Power Supply
1
2
3
156
1 power supply
3 cable retention bracket
2 locking tab
Installing a Power Supply
1 Verify that power supplies are the same type and have the same maximum output power.
NOTE:
The maximum output power (shown in watts) is listed on the power supply label.
2 If applicable, remove the power supply blank. See "Removing the Power
3 Slide the new power supply into the chassis until the power supply is fully
seated and the release latch snaps into place. See Figure 3-32.
NOTE:
If you unlatched the cable management arm in step of the previous
procedure, relatch it. For information about the cable management arm, see the system’s rack documentation.
4 Connect the power cable to the power supply and plug the cable into a power outlet.
Installing System Components
book.book Page 157 Wednesday, January 20, 2010 10:20 AM
CAUTION:
When connecting the power cable, secure the cable with the Velcro strap.
NOTE:
When installing, hot-swapping, or hot-adding a new power supply in a system, allow several seconds for the system to recognize the power supply and determine its status. The power-supply status indicator turns green to signify that the power supply is functioning properly.
Removing the Power Supply Blank
If you are installing a power supply, remove the power supply blank by pulling outward on the blank.
CAUTION:
To ensure proper system cooling, the power supply blank must be installed in each power supply bay that does not have a power supply. Remove the power supply blank only if you are installing an additional power supply.
Installing the Power Supply Blank
NOTE:
Install the power supply blank only in power supply bays 2, 3, or 4.
To install the power supply blank, align the blank with the power supply bay and insert the blank into the chassis until it clicks into place.
System Battery
Replacing the System Battery
WARNING:
There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. See your safety information for additional information.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
Installing System Components
157
book.book Page 158 Wednesday, January 20, 2010 10:20 AM
Figure 3-33.
Replacing the System Battery
1
2
3
1 positive side of battery connector
3 negative side of battery connector
2 system battery
3 Locate the battery socket. See "System Board Connectors" on page 198.
CAUTION:
To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.
4 To remove the battery, support the battery connector by pressing down firmly on the positive side of the connector.
5 Press the battery toward the positive side of the connector and lift it up out of the securing tabs at the negative side of the connector.
6 To install a new system battery, support the battery connector by pressing down firmly on the positive side of the connector.
7 Hold the battery with the "+" facing up and slide it under the securing tabs at the positive side of the connector.
8 Press the battery straight down into the connector until it snaps into place.
9 Close the system. See "Closing the System" on page 90.
10 Reconnect the system to the electrical outlet and turn the system on, including any attached peripherals.
158
Installing System Components
book.book Page 159 Wednesday, January 20, 2010 10:20 AM
11 Enter the System Setup program to confirm that the battery is operating
properly. See "Using the System Setup Program and UEFI Boot Manager" on page 63.
12 Enter the correct time and date in the System Setup program's Time and
Date fields.
13 Exit the System Setup program.
SAS Backplane
NOTE:
Depending on your configuration, your system supports either an x16 SAS backplane or an x4 SAS backplane. The illustration in this section shows the removal and installation of an x16 SAS backplane.
Removing the SAS Backplane
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
CAUTION:
To prevent damage to the drives and backplane, you must remove the hard drives from the system before removing the backplane.
CAUTION:
You must note the number of each hard drive and temporarily label them before removal so that you can replace them in the same locations.
4 Remove all hard drives. See "Removing a Hard Drive" on page 109.
5 If applicable, remove the memory-riser blanks. See "Removing a Memory-
6 Remove the memory risers. See "Removing a Memory Riser" on page 100.
7 Disconnect the SAS data cable(s) and power cable from the backplane.
8 If applicable, disconnect the power/data cable from the optical drive.
Installing System Components
159
book.book Page 160 Wednesday, January 20, 2010 10:20 AM
9 Pull the blue release pin(s) and slide the backplane upwards.
10 Pull the backplane away from the front of the system until the securing slots are free from the tabs on the chassis.
Figure 3-34.
Removing and Installing a SAS Backplane
1 2
3
5
1 SAS backplane
3 release pins (2)
5 SAS cables (2)
4
160
Installing System Components
2 power cable
4 chassis tabs
book.book Page 161 Wednesday, January 20, 2010 10:20 AM
Installing the SAS Backplane
NOTE:
If you are installing an x16 SAS backplane, you must remove all the three chassis blanks from the system. If you are installing an x4 SAS backplane, you must ensure that all the three chassis blanks are installed in the system.
1 Align the slots on the SAS backplane with the tabs on the chassis.
2 Slide down the SAS backplane until the release pin snaps into place.
3 Connect the SAS data cable(s) and power cable to the backplane.
4 If applicable, connect the optical drive power/data cable.
5 Install the memory risers. See "Installing a Memory Riser" on page 101.
6 If applicable, install the memory-riser blanks. See "Installing a Memory-
7 Install the hard drives in their original locations. See "Installing a Hard
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
10 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
Power Distribution Board
Removing the Power Distribution Board
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2 Remove the power supplies from the system. See "Removing a Power
3 Open the system. See "Opening the System" on page 89.
Installing System Components
161
book.book Page 162 Wednesday, January 20, 2010 10:20 AM
4 If applicable, remove the memory-riser blanks. See "Removing a Memory-
5 Remove the memory risers. See "Removing a Memory Riser" on page 100.
6 Remove the cooling fan assembly. See "Removing the Cooling Fan
7 Slide the board upwards and pull the board toward the front of the system until the tabs on the board are free from the securing slots on the chassis.
Figure 3-35.
Power Distribution Board
3
2
4
1
1 power distribution board connector 2 power distribution board
3 tabs (2) 4 securing slots (2)
162
Installing System Components
book.book Page 163 Wednesday, January 20, 2010 10:20 AM
Replacing the Power Distribution Board
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Unpack the new power distribution board assembly.
2 Align the tabs on the board with the slots on the chassis.
3 Press the board into the connector until it is fully seated.
4 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.
5 Install the memory risers. See "Installing a Memory Riser" on page 101.
6 If applicable, install the memory-riser blanks. See "Installing a Memory-
7 Close the system. See "Closing the System" on page 90.
8 Install the power supplies in the system. See "Installing a Power Supply" on page 156.
9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Control Panel Assembly
Removing the Control Panel Display Module
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on page 87.
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Installing System Components
163
book.book Page 164 Wednesday, January 20, 2010 10:20 AM
3 Open the system. See "Opening the System" on page 89.
4 Disconnect the display module cable from the control panel board.
5 Using a knife or a small flat-blade screwdriver, insert the blade beneath the front panel of the display and slide the blade across the bottom to lift the
panel outward. See Figure 3-36.
6 Bend the panel upward to access to the mounting screws.
7 Using a T10 Torx driver, remove the two screws that secure the display module to the system chassis.
8 Remove the display module from the chassis cutout.
Installing the Control Panel Display Module
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Insert the display module into the chassis cutout and secure the module
with the two Torx screws. See Figure 3-36.
2 Attach the replacement panel to the front of the display module.
3 Connect the display module cable to the control panel board.
4 Close the system. See "Closing the System" on page 90.
5 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
6 If applicable, install the front bezel. See "Installing the Front Bezel" on page 87.
164
Installing System Components
book.book Page 165 Wednesday, January 20, 2010 10:20 AM
Figure 3-36.
Removing or Installing the Control Panel Assembly
1 2 3 4 5
1 T8 Torx screw
3 control panel board
5 control panel cable
7 display module
7
2 T10 Torx screws (3)
4 USB cable
6 display module cable
6
Installing System Components
165
book.book Page 166 Wednesday, January 20, 2010 10:20 AM
Removing the Control Panel Board
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the memory-riser blanks. See "Removing a Memory-
4 Remove the memory risers. See "Removing a Memory Riser" on page 100.
5 Remove the memory-riser guide. See "Removing the Memory-Riser Guide" on page 106.
6 Disconnect the cables connected to the control panel board.
NOTE:
Note the routing of the cables on the side on the system as you remove them from the control panel board. You must route these cables properly when you replace them to prevent them from being pinched or crimped.
7 Using a T10 Torx driver, remove the three screws that secure the control
panel board to the chassis. See Figure 3-36.
8 Using a T8 Torx driver, remove the screw that secures the control panel
board on the front of the system. See Figure 3-36.
9 Slide the control panel assembly toward the back of the system and take it out.
166
Installing System Components
book.book Page 167 Wednesday, January 20, 2010 10:20 AM
Installing the Control Panel Board
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Align the screw holes on the control panel board with the holes on the chassis.
2 Using a T10 Torx driver, replace the screws that secure the control panel
board to the chassis. See Figure 3-36.
3 Using a T8 Torx driver, replace the screw that secures the control panel
board on the front of the system. See Figure 3-36.
4 Connect all the cables to the control panel board.
5 Install the memory-riser guide. See "Installing the Memory-Riser Guide" on page 107.
6 Install the memory risers. See "Installing a Memory Riser" on page 101.
7 If applicable, install the memory-riser blanks. See "Installing a Memory-
8 Close the system. See "Closing the System" on page 90.
9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing System Components
167
book.book Page 168 Wednesday, January 20, 2010 10:20 AM
168
System Board
Removing the System Board
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION:
If you are using the Trusted Program Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or system setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your hard drives.
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 If applicable, remove the memory-riser blanks. See "Removing a Memory-
4 Remove the memory risers. See "Removing a Memory Riser" on page 100.
5 Remove the cooling fan assembly. See "Removing the Cooling Fan
6 Remove the power supply(s). See "Removing a Power Supply" on page 155.
7 Remove all expansion cards, the I/O card, and the integrated storage
controller card. See "Removing an Expansion Card" on page 128,
"Removing the I/O Card" on page 134, and "Removing the Integrated
Storage Controller Card" on page 143.
8 If applicable, remove the USB key from the system board. See "Internal
9 If applicable, remove the NIC hardware key from the system board. See
"Integrated NIC Hardware Key" on page 123.
10 Remove the processor(s). See "Removing a Processor" on page 148.
11 Remove the power distribution board. See "Removing the Power
Distribution Board" on page 161.
Installing System Components
book.book Page 169 Wednesday, January 20, 2010 10:20 AM
12 Disconnect all cables from the system board.
13 Loosen the thumbscrew that secures the system board to the chassis.
14 Pull the blue release pin and slide the system board toward the front of the system.
CAUTION:
Do not lift the system board assembly by grasping a memory module, processor, or other components.
15 Grasp the system board using the handle and the card guides. Angle the system board toward the front of the system and lift the board out of the chassis.
Figure 3-37.
Removing and Installing the System Board
5
4
1 system board
3 card guide
5 thumbscrew
3
2 handle
4 release pin
2
1
Installing System Components
169
book.book Page 170 Wednesday, January 20, 2010 10:20 AM
170
Installing the System Board
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Unpack the new system board.
2 Remove the labels from the processor shield and affix them to the system
identification panel on the front of the system. See Figure 3-37.
3 Using the handle and the card guide, lower the system board into the chassis.
CAUTION:
Do not lift the system board assembly by grasping a memory module, processor, or other components.
4 Slightly lift up the front of the system board and maneuver the system board to the bottom of the chassis until it lays completely flat.
5 Push the system board toward the back of the chassis until the board clicks into place.
6 Tighten the thumbscrew that secures the system board to the chassis.
7 Connect all the cables to the system board.
8 Install the power distribution board. See "Replacing the Power
Distribution Board" on page 163.
9 Transfer the processors to the new system board. See "Removing a
Processor" on page 148 and "Installing a Processor" on page 152.
10 If applicable, install the NIC hardware key on the system board. See
"Integrated NIC Hardware Key" on page 123.
11 If applicable, install the internal USB key on the system board. See
"Internal USB Memory Key" on page 120.
12 Install all expansion cards, the I/O card, and the integrated storage
controller card. See "Installing an Expansion Card" on page 126, "Installing
the I/O Card" on page 135, and "Installing the Integrated Storage
13 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.
Installing System Components
book.book Page 171 Wednesday, January 20, 2010 10:20 AM
14 Install the memory risers in the same locations on the new board. See
"Installing a Memory Riser" on page 101.
15 If applicable, install the memory-riser blanks. See "Installing a Memory-
16 Close the system. See "Closing the System" on page 90.
17 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing System Components
171
book.book Page 172 Wednesday, January 20, 2010 10:20 AM
172
Installing System Components
book.book Page 173 Wednesday, January 20, 2010 10:20 AM
Troubleshooting Your System
Safety First—For You and Your System
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Troubleshooting System Startup Failure
If your system halts during startup prior to video imaging or LCD messaging, especially after installing an operating system or reconfiguring your system’s hardware, check for the following conditions:
• If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot Manager, the system will hang. The reverse is also true. You must boot to the same boot mode in which you installed the
operating system. See "Using the System Setup Program and UEFI Boot
• Invalid memory configurations could cause the system to halt at startup
without any video output. See "System Memory" on page 91.
For all other startup issues, note the LCD panel messages and any system
messages that appear onscreen. See "LCD Status Messages" on page 23 and
"System Messages" on page 41 for more information.
Troubleshooting External Connections
Ensure that all external cables are securely attached to the external connectors on your system before troubleshooting any external devices. See
Figure 1-1 and Figure 1-3 for the front- and back-panel connectors on your
system.
Troubleshooting Your System
173
book.book Page 174 Wednesday, January 20, 2010 10:20 AM
174
Troubleshooting the Video Subsystem
1 Check the system and power connections to the monitor.
2 Check the video interface cabling from the system to the monitor.
3 If two monitors are attached to the system, disconnect one monitor. The system supports only one monitor attached to either the front or rear video connector.
4 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.
If the tests run successfully, the problem is not related to video hardware.
If the tests fail, see "Getting Help" on page 203.
Troubleshooting a USB Device
1 Use the following steps to troubleshoot a USB keyboard and/or mouse. For other USB devices, go to step 2.
a Disconnect the keyboard and mouse cables from the system briefly and reconnect them. b Connect the keyboard/mouse to the USB port(s) on the opposite side of the system.
If the problem is resolved, restart the system, enter the System Setup program, and check if the nonfunctioning USB ports are enabled. c Replace the keyboard/mouse with another working keyboard/mouse.
If the problem is resolved, replace the faulty keyboard/mouse.
If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to the system.
2 Power down all attached USB devices and disconnect them from the system.
3 Restart the system and, if your keyboard is functioning, enter the system
setup program. Verify that all USB ports are enabled. See "Integrated
If your keyboard is not functioning, you can also use remote access. If the
system is not accessible, see "Disabling a Forgotten Password" on page 201
Troubleshooting Your System
book.book Page 175 Wednesday, January 20, 2010 10:20 AM for instructions on setting the NVRAM_CLR jumper inside your system and restoring the BIOS to the default settings.
4 Reconnect and power on each USB device one at a time.
5 If a device causes the same problem, power down the device, replace the
USB cable, and power up the device.
If the problem persists, replace the device.
If all troubleshooting fails, see "Getting Help" on page 203.
Troubleshooting a Serial I/O Device
1 Turn off the system and any peripheral devices connected to the serial port.
2 Swap the serial interface cable with a working cable, and turn on the system and the serial device.
If the problem is resolved, replace the interface cable.
3 Turn off the system and the serial device, and swap the device with a comparable device.
4 Turn on the system and the serial device.
If the problem is resolved, replace the serial device.
If the problem persists, see "Getting Help" on page 203.
Troubleshooting a NIC
1 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.
2 Restart the system and check for any system messages pertaining to the
NIC controller.
3 Check the appropriate indicator on the NIC connector. See "NIC Indicator
• If the link indicator does not light, check all cable connections.
• If the activity indicator does not light, the network driver files might be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC's documentation.
Troubleshooting Your System
175
book.book Page 176 Wednesday, January 20, 2010 10:20 AM
176
• Change the autonegotiation setting, if possible.
• Use another connector on the switch or hub.
If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.
4 Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.
5 Enter the System Setup program and confirm that the NIC ports are
enabled. See "Integrated Devices Screen" on page 70.
6 Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and duplex. See the documentation for each network device.
7 Ensure that all network cables are of the proper type and do not exceed the maximum length.
If all troubleshooting fails, see "Getting Help" on page 203.
Troubleshooting a Wet System
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See"Opening the System" on page 89.
3 Disassemble components from the system. See "Installing System
• Hard drives
• Optical drive
• Memory risers
• Cooling fan assembly
• SD cards
Troubleshooting Your System
book.book Page 177 Wednesday, January 20, 2010 10:20 AM
• USB memory key
• NIC hardware key
• Expansion cards and both expansion-card risers
• I/O card
• Integrated storage controller
• Power supplies
• Processors and heat sinks
4 Let the system dry thoroughly for at least 24 hours.
5 Reinstall the components you removed in step 3.
6 Close the system. See "Closing the System" on page 90.
7 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the system does not start properly, see "Getting Help" on page 203.
8 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.
If the tests fail, see "Getting Help" on page 203.
Troubleshooting a Damaged System
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
3 Ensure that the following components are properly installed:
• Hard drives
• Memory risers
• Cooling fan assembly
Troubleshooting Your System
177
book.book Page 178 Wednesday, January 20, 2010 10:20 AM
178
• SD cards
• USB memory key
• NIC hardware key
• Expansion cards and both expansion-card risers
• I/O card
• Integrated storage controller
• Power supplies
• Processors and heat sinks
4 Ensure that all cables are properly connected.
5 Close the system. See "Closing the System" on page 90.
6 Run the system board tests in the system diagnostics. See "Running the
Embedded System Diagnostics" on page 194.
If the tests fail, see "Getting Help" on page 203.
Troubleshooting the System Battery
NOTE:
If the system is turned off for long periods of time (for weeks or months), the
NVRAM may lose its system configuration information. This situation is caused by a defective battery.
2 Turn off the system and disconnect it from the electrical outlet for at least one hour.
3 Reconnect the system to the electrical outlet and turn on the system.
4 Enter the System Setup program.
If the date and time are not correct in the System Setup program, replace
the battery. See "Replacing the System Battery" on page 157.
NOTE:
Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.
If the problem is not resolved by replacing the battery, see "Getting Help" on page 203.
Troubleshooting Your System
book.book Page 179 Wednesday, January 20, 2010 10:20 AM
Troubleshooting Power Supplies
CAUTION:
At least one power supply must be installed for the system to operate.
Operating the system with only one power supply installed for extended periods of time can cause the system to overheat.
1 Identify the faulty power supply by the power supply's fault indicator. See
"Power Indicator Codes" on page 22.
CAUTION:
If troubleshooting a power supply mismatch error, replace only the power supply with the flashing indicator. Swapping the opposite power supply to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to an Energy Smart configuration or vice versa, you must power down the system.
2 Reseat the power supply by removing and reinstalling it. See "Removing a
Power Supply" on page 155 and "Installing a Power Supply" on page 156.
NOTE:
After installing a power supply, allow several seconds for the system to recognize the power supply and to determine if it is working properly. The power indicator turns green to signify that the power supply is functioning properly.
If the problem persists, replace the faulty power supply.
3 If the problem persists, see "Getting Help" on page 203.
Troubleshooting Your System
179
book.book Page 180 Wednesday, January 20, 2010 10:20 AM
Troubleshooting System Cooling Problems
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Ensure that none of the following conditions exist:
• System cover, drive blank, memory-module blank, power-supply blank, or back filler bracket is removed.
• Ambient temperature is too high. See your Getting Started Guide for your system’s operating temperature requirements.
• External airflow is obstructed.
• Cables inside the system obstruct airflow.
•
An individual cooling fan is removed or has failed. See"Troubleshooting a
• The expansion card installation guidelines have not been followed. See
"Expansion Card Installation Guidelines" on page 124.
Troubleshooting a Fan
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Open the system. See "Opening the System" on page 89.
CAUTION:
The cooling fans are hot-swappable. To maintain proper cooling while the system is on, only replace one fan at a time.
2 Locate the faulty fan indicated by the LCD panel or the diagnostic software
180
Troubleshooting Your System
book.book Page 181 Wednesday, January 20, 2010 10:20 AM
3 Remove and reseat the fan. See "Removing a Cooling Fan" on page 116
and "Installing a Cooling Fan" on page 117.
NOTE:
Wait at least 30 seconds for the system to recognize the fan and determine whether it is working properly.
4 If the problem is not resolved, install a new fan. See "Removing a Cooling
Fan" on page 116 and "Installing a Cooling Fan" on page 117.
If the replacement fan is working properly, close the system. See "Closing the System" on page 90.
If the replacement fan does not operate, see "Getting Help" on page 203.
Troubleshooting System Memory
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE:
Invalid memory configurations can cause your system to halt at startup
guidelines.
1 If the system is operational, run the appropriate online diagnostic test. See
"Using Online Diagnostics" on page 193.
If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.
2 If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at least 10 seconds and then reconnect the system to power.
3 Turn on the system and attached peripherals and note the messages on the screen.
Go to step 14 if an error message appears indicating a fault with a specific memory module.
Troubleshooting Your System
181
book.book Page 182 Wednesday, January 20, 2010 10:20 AM
4 Enter the System Setup program and check the system memory setting.
See "Memory Settings Screen" on page 67. Make any changes to the
memory settings, if needed.
If the memory settings match the installed memory but a problem is still indicated, go to step 14.
5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6 Open the system. See "Opening the System" on page 89.
7 Remove the memory risers. See "Removing a Memory Riser" on page 100.
8 Check the memory channels and ensure that they are populated correctly.
See "General Memory Module Installation Guidelines" on page 92.
9 Reseat the memory modules in their sockets. See "Installing Memory
10 Install the memory risers. See "Installing a Memory Riser" on page 101.
11 Close the system. See "Closing the System" on page 90.
12 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
13 Enter the System Setup program and check the system memory setting.
See "Memory Settings Screen" on page 67.
If the problem is not resolved, proceed with the next step.
14 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module.
15 Open the system. See "Opening the System" on page 89.
16 Remove the memory risers. See "Removing a Memory Riser" on page 100.
17 To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 102.
18 Install the memory risers. See "Installing a Memory Riser" on page 101.
19 Close the system. See "Closing the System" on page 90.
20 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
182
Troubleshooting Your System
book.book Page 183 Wednesday, January 20, 2010 10:20 AM
21 As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system.
22 If the memory problem is still indicated, repeat step 14 through step 19 for
each memory module installed.
If the problem persists after all memory modules have been checked, see
Troubleshooting an Internal USB Key
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Enter the System Setup program and ensure that the internal USB key
port is enabled. See "Integrated Devices Screen" on page 70.
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 Locate the USB key and reseat it. See "Internal USB Memory Key" on page 120.
5 Close the system. See "Closing the System" on page 90.
6 Turn on the system and attached peripherals and check if the USB key is functioning.
7 If the problem is not resolved, repeat step 2 and step 3.
8 Insert a different USB key that you know works properly.
9 Close the system. See "Closing the System" on page 90.
10 Turn on the system and attached peripherals and check if the USB key is functioning.
If the problem is not resolved, see "Getting Help" on page 203.
Troubleshooting Your System
183
book.book Page 184 Wednesday, January 20, 2010 10:20 AM
184
Troubleshooting an Internal SD Card
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Enter the System Setup program and ensure that the internal SD card port
is enabled. See "Integrated Devices Screen" on page 70.
2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 Reseat the SD module cable. See "Installing the Internal Dual SD Module" on page 141.
CAUTION:
If the Redundancy option is set to Mirror Mode in the Integrated
NOTE:
When an SD card failure occurs, the internal dual SD module controller notifies the system. On the next reboot, the system prompts you with a message indicating the failure.
7 Insert the new SD card into the SD2 slot.
8 Close the system. See "Closing the System" on page 90.
9 Turn on the system and attached peripherals and check if the SD card is functioning.
If the problem is not resolved, see "Getting Help" on page 203.
10 Insert a different SD card that you know works properly.
Troubleshooting Your System
book.book Page 185 Wednesday, January 20, 2010 10:20 AM
11 Close the system. See "Closing the System" on page 90.
12 Turn on the system and attached peripherals and check if the SD card is functioning.
If the problem is not resolved, see "Getting Help" on page 203.
Troubleshooting an Optical Drive
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 If applicable, remove the bezel. See "Removing the Front Bezel" on page 87.
2 Try using a different CD or DVD.
3 Enter the System Setup program and ensure that the integrated SATA
controller and the drive's SATA port are enabled. See "Using the System
Setup Program and UEFI Boot Manager" on page 63.
4 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.
5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6 Open the system. See "Opening the System" on page 89.
7 Ensure that the interface cable is securely connected to the optical drive
and to the system board. See "Optical Drive" on page 113.
8 Ensure that a power cable is properly connected to the drive.
9 Close the system. See "Closing the System" on page 90.
10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, see "Getting Help" on page 203.
Troubleshooting Your System
185
book.book Page 186 Wednesday, January 20, 2010 10:20 AM
186
Troubleshooting a Tape Backup Unit
1 Ensure that the tape drive is turned on.
2 Try using a different tape cartridge.
3 Ensure that the device drivers for the tape drive are installed and are configured correctly. See your tape drive documentation for more information about device drivers.
4 Ensure that the tape drive’s interface cable is fully connected to the external port on the controller card.
5 For SCSI tape drives, verify that the tape drive is configured for a unique
SCSI ID number and that the tape drive is terminated or not terminated, based on the interface cable used to connect the drive. See the documentation for the tape drive for instructions on selecting the SCSI ID number and enabling or disabling termination.
6 Run the appropriate online diagnostics tests. See "Using Online
If you cannot resolve the problem, see "Getting Help" on page 203.
7 Reinstall the tape-backup software as instructed in the tape-backup software documentation. See your tape documentation for information about reinstalling the software and troubleshooting the tape drive.
Troubleshooting a Hard Drive
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION:
This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.
1 Run the appropriate online diagnostics test. See "Using Online
Depending on the results of the diagnostics test, proceed as needed through the following steps.
Troubleshooting Your System
book.book Page 187 Wednesday, January 20, 2010 10:20 AM
2 If applicable, remove the bezel. See "Removing the Front Bezel" on page 87.
3 If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following steps.
a Restart the system and enter the host adapter configuration utility program by pressing <Ctrl><R> for a PERC controller or
<Ctrl><C> for a SAS controller.
See the documentation supplied with the host adapter for information about the configuration utility.
b c
Ensure that the hard drive(s) have been configured correctly for the
RAID array.
Take the hard drive offline and reseat the drive. See "Removing a Hard
d Exit the configuration utility and allow the system to boot to the operating system.
4 Ensure that the required device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information.
5 Restart the system, enter the System Setup program, and verify that the controller is enabled and the drives appear in the System Setup program.
See "Using the System Setup Program and UEFI Boot Manager" on page 63.
If the problem persists, see "Troubleshooting a Storage Controller" on page 187.
Troubleshooting a Storage Controller
NOTE:
When troubleshooting a SAS or PERC controller, also see the documentation for your operating system and the controller.
1 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.
2 Enter the System Setup program and ensure that the SAS or PERC
controller is enabled. See "Using the System Setup Program and UEFI
Troubleshooting Your System
187
book.book Page 188 Wednesday, January 20, 2010 10:20 AM
3 Restart the system and press the applicable key sequence to enter the configuration utility program:
• <Ctrl><C> for a SAS controller
• <Ctrl><R> for PERC controller
See the controller's documentation for information about configuration settings.
4 Check the configuration settings, make any necessary corrections, and restart the system.
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
5 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
6 Open the system. See "Opening the System" on page 89.
7 Ensure that the controller card is firmly seated into the system board
connector. See "Integrated Storage Controller Card" on page 143.
8 If you have a PERC controller with a battery-backed cache, ensure that the
RAID battery is properly connected and, if applicable, the memory module on the PERC card is properly seated.
9 Verify that the cable connections between the SAS backplane and the
integrated storage controller are correct. See "Installing the Integrated
Storage Controller Card" on page 145 and Figure 6-2.
Ensure that the cables are firmly connected to the storage controller and the SAS backplane board.
10 Close the system. See "Closing the System" on page 90.
11 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
If the problem persists, see "Getting Help" on page 203.
188
Troubleshooting Your System
book.book Page 189 Wednesday, January 20, 2010 10:20 AM
Troubleshooting Expansion Cards
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE:
When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.
1 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 193.
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 Verify that the installed expansion cards are compliant with the expansion
card installation guidelines. See "Expansion Card Installation Guidelines" on page 124.
5 Ensure that each expansion card is firmly seated in its connector. See
"Installing an Expansion Card" on page 126.
6 Close the system. See "Closing the System" on page 90.
7 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
8 If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
9 Open the system. See "Opening the System" on page 89.
10 Remove all expansion cards installed in the system. See "Removing an
11 Close the system. See "Closing the System" on page 90.
12 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13 Run the appropriate online diagnostic test.
If the tests fail, see "Getting Help" on page 203.
Troubleshooting Your System
189
book.book Page 190 Wednesday, January 20, 2010 10:20 AM
190
14 For each expansion card you removed in step 10, perform the following steps: a Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
b c d e
Open the system. See "Opening the System" on page 89.
Reinstall one of the expansion cards.
Close the system. See "Closing the System" on page 90.
Run the appropriate diagnostic test.
If the tests fail, see "Getting Help" on page 203.
Troubleshooting the Processors
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1 Run the appropriate online diagnostics test. See "Using Online
2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3 Open the system. See "Opening the System" on page 89.
4 Remove the memory risers. See "Removing a Memory Riser" on page 100.
5 Remove the cooling fan assembly. See "Removing the Cooling Fan
6 Ensure that each processor and heat sink are properly installed. See
"Removing a Processor" on page 148.
7 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.
8 Install the memory risers. See "Installing a Memory Riser" on page 101.
9 Close the system. See "Closing the System" on page 90.
10 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Troubleshooting Your System
book.book Page 191 Wednesday, January 20, 2010 10:20 AM
11 Run the appropriate online diagnostic test.
If the problem still persists, see step 12.
12 Open the system. See "Opening the System" on page 89.
13 Remove the memory risers. See "Removing a Memory Riser" on page 100.
14 Remove the cooling fan assembly. See "Removing the Cooling Fan
15 If your system has four processors, remove all processors except for
processor 1 and processor 2. See "Installing a Processor" on page 152.
16 Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.
17 Install the memory risers. See "Installing a Memory Riser" on page 101.
18 Close the system. See "Closing the System" on page 90.
19 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
20 Run the appropriate online diagnostic test.
If the test fails, the processor is faulty. See "Getting Help" on page 203.
If the test passes, replace processor 1 and 2 with processor 3 and processor
4. Run the appropriate online diagnostic test. If the test fails, the processor
is faulty. See "Getting Help" on page 203.
Troubleshooting Your System
191
book.book Page 192 Wednesday, January 20, 2010 10:20 AM
192
Troubleshooting Your System
book.book Page 193 Wednesday, January 20, 2010 10:20 AM
Running the System Diagnostics
If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your system's hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use diagnostics test results to help you solve the problem.
Using Online Diagnostics
To assess a system problem, first use the online diagnostics. Online
Diagnostics is a suite of diagnostic programs, or test modules, that include diagnostic tests on chassis and storage components such as hard drives, physical memory, communications, NICs, CMOS, and more. If you are unable to identify the problem using the online diagnostics, then use the embedded system diagnostics.
The files required to run the online diagnostics for systems running supported
Microsoft
®
Windows
®
and Linux operating systems are available at support.dell.com and on the CDs that came with your system. For information about using diagnostics, see the Dell Online Diagnostics User's
Guide.
Embedded System Diagnostics Features
The system diagnostics provides a series of menus and options for particular device groups or devices. The system diagnostics menus and options allow you to:
• Run tests individually or collectively
• Control the sequence of tests
• Repeat tests
• Display, print, or save test results
• Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is reached
• View help messages that briefly describe each test and its parameters
Running the System Diagnostics
193
book.book Page 194 Wednesday, January 20, 2010 10:20 AM
• View status messages that inform you if tests are completed successfully
• View error messages that inform you of problems encountered during testing
When to Use the Embedded System Diagnostics
If a major component or device in the system does not operate properly, component failure may be indicated. As long as the processor and the system's input/output devices are functioning, you can use the embedded system diagnostics to help identify the problem.
Running the Embedded System Diagnostics
The embedded system diagnostics program is run from the Lifecycle
Controller screen.
CAUTION:
Use the embedded system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages.
1 As the system boots, press <F10>.
2 Click Diagnostics in the left pane and click Launch Diagnostics in the right pane.
The Diagnostics menu allows you to run all or specific diagnostics tests or to exit.
System Diagnostics Testing Options
Click the testing option in the Main Menu window.
Testing Option
Express Test
Extended Test
Custom Test
Information
Function
Performs a quick check of the system. This option runs device tests that do not require user interaction.
Performs a more thorough check of the system. This test can take an hour or longer.
Tests a particular device.
Displays test results.
194
Running the System Diagnostics
book.book Page 195 Wednesday, January 20, 2010 10:20 AM
Using the Custom Test Options
When you select Custom Test in the Main Menu window, the Customize window allows you to select the device(s) to be tested, select specific options for testing, and view the test results.
Selecting Devices for Testing
The left side of the Customize window lists devices that can be tested. Click the (+) next to a device or module to view its components. Click (+) on any component to view the tests that are available. Clicking a device, rather than its components, selects all of the components of the device for testing.
NOTE:
After you select all the devices and components that you want to test, highlight All Devices and then click Run Tests.
Selecting Diagnostics Options
From the Diagnostics Options area, select the test(s) you want to run on a device.
• Non-Interactive Tests Only — Runs only tests that require no user intervention.
• Quick Tests Only — Runs only the quick tests on the device.
• Show Ending Timestamp — Time stamps the test log.
• Test Iterations — Selects the number of times the test is run.
• Log output file pathname — Enables you to specify the diskette drive or
USB memory key where the test log file is saved. You cannot save the file to a hard drive.
Running the System Diagnostics
195
book.book Page 196 Wednesday, January 20, 2010 10:20 AM
Viewing Information and Results
The following tabs in the Customize window provide information about the test and the test results.
• Results — Displays the test that ran and the result.
• Errors — Displays any errors that occurred during the test.
• Help — Displays information about the currently selected device, component, or test.
• Configuration — Displays basic configuration information about the currently selected device.
• Parameters — Displays parameters that you can set for the test.
196
Running the System Diagnostics
book.book Page 197 Wednesday, January 20, 2010 10:20 AM
Jumpers and Connectors
System Board Jumper
For information on resetting the password jumper to disable a password, see
"Disabling a Forgotten Password" on page 201.
Table 6-1.
System Board Jumper Settings
Jumper
PWRD_EN
Setting Description
(default) The password feature is enabled (pins 2-4)
NVRAM_CLR
The password feature is disabled, and iDRAC6 local access is unlocked at the next AC power cycle (pins 4-6)
(default) The configuration settings are retained at system boot (pins 3-5)
The configuration settings are cleared at the next system boot (pins 1-3)
Jumpers and Connectors
197
book.book Page 198 Wednesday, January 20, 2010 10:20 AM
7
6
5
4
3
2
1
System Board Connectors
Figure 6-1.
System Board Connectors
10 11
9
8
32 31 30 29 28 27 26 25 24 23
16
17
18
19
20
21
22
12
13
14
15
198
Jumpers and Connectors
book.book Page 199 Wednesday, January 20, 2010 10:20 AM
Table 6-2.
System Board Jumpers and Connectors
16
17
18
19
12
13
14
15
20
21
Item Connector
7
8
5
6
3
4
1
2
9
10
11
CTRL_PNL
CTRL_USB
SATA_A
J_CPU4
J_CPU2
FAN1
J_PDB_MISC
FAN4
INT_USB
SLOT 1
SLOT2
SLOT3
SLOT4
SLOT5
SLOT6
PWRD_EN
NVRAM_CLR
SLOT7
IO_RISER
INT_STORAGE
J_SLOT7PWR
FAN5
ISCSI_KEY
FAN2
FAN6
FAN3
J_CPU3
Description
Control panel interface connector
Control panel USB interface connector
SATA A connector
Processor 4
Processor 2
System cooling fan 1
Power distribution board connector
System cooling fan 4
Internal USB connector
PCIE_G2_X4
PCIE_G2_X8
PCIE_G2_X8
PCIE_G2_X8
PCIE_G2_X4
PCIE_G2_X4
Password enable jumper
NVRAM clear jumper
PCIE_G2_X16
I/O card connector
Internal storage controller card connector
Power connector
System cooling fan 5
NIC hardware key
System cooling fan 2
System cooling fan 6
System cooling fan 3
Processor 3
Jumpers and Connectors
199
book.book Page 200 Wednesday, January 20, 2010 10:20 AM
Table 6-2.
System Board Jumpers and Connectors
Item Connector
26
27
28
29
22
23
24
25
30
31
32
J_CPU1
MEM_RISER_A
MEM_RISER_B
MEM_RISER_E
MEM_RISER_F
MEM_RISER_C
MEM_RISER_D
MEM_RISER_G
BP_PWR/MISC
MEM_RISER_H
SATA_PWR
Description
Processor 1
Memory riser A connector
Memory riser B connector
Memory riser E connector
Memory riser F connector
Memory riser C connector
Memory riser D connector
Memory riser G connector
Power connector
Memory riser H connector
SATA power connector
SAS Backplane Board Connectors
Figure 6-2.
x16 SAS Backplane Board Connector
4
5
6
1
2 3
200
Jumpers and Connectors
book.book Page 201 Wednesday, January 20, 2010 10:20 AM
1 hard-drive connectors 0–3
3 hard-drive connectors 8–11
5 SAS connectors (2)
Figure 6-3.
x4 SAS Backplane Board Connector
2 hard-drive connectors 4–7
4 power connector
6 hard-drive connectors 12–15
1
3
2
1 power connector
3 SAS connector
2 hard-drive connectors 0–3
Disabling a Forgotten Password
The system's software security features include a system password and a setup
password features or disables them and clears any password(s) currently in use.
CAUTION:
See "Protecting Against Electrostatic Discharge" in the safety instructions that came with the system.
1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 89.
Jumpers and Connectors
201
book.book Page 202 Wednesday, January 20, 2010 10:20 AM
3 Remove the jumper plug from the password jumper.
See Figure 6-1 to locate the password jumper (labeled "PWRD_EN") on the system board.
4 Close the system.
5 Reconnect your system and peripherals to their electrical outlets, and turn on the system.
The existing passwords are not disabled (erased) until the system boots with the password jumper plug removed. However, before you assign a new system and/or setup password, you must install the jumper plug.
NOTE:
If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next time it boots.
6 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
7 Open the system. See "Closing the System" on page 90.
8 Install the jumper plug on the password jumper.
9 Lower the memory module shroud.
10 Close the system.
11 Reconnect your system and peripherals to their electrical outlets, and turn on the system.
12 Assign a new system and/or setup password.
202
Jumpers and Connectors
book.book Page 203 Wednesday, January 20, 2010 10:20 AM
Getting Help
Contacting Dell
For customers in the United States, call 800-WWW-DELL (800-999-3355).
NOTE:
If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog.
Dell provides several online and telephone-based support and service options.
Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:
1 Visit support.dell.com.
2 Verify your country or region in the Choose A Country/Region drop-down menu at the bottom of the page.
3 Click Contact Us on the left side of the page.
4 Select the appropriate service or support link based on your need.
5 Choose the method of contacting Dell that is convenient for you.
Getting Help
203
book.book Page 204 Wednesday, January 20, 2010 10:20 AM
204
Getting Help
book.book Page 205 Wednesday, January 20, 2010 10:20 AM
Index
B batteries
battery
troubleshooting the RAID card battery, 187
battery (system)
blank
C cabling
CD drive
CD/DVD drive
connectors
control panel assembly
cooling fans
D damaged systems
Dell
Dell PowerEdge Diagnostics
diagnostics
advanced testing options, 193 testing options, 193 using Dell PowerEdge
DIMMs
drive blank
drive carrier
E
expansion card
Index
205
book.book Page 206 Wednesday, January 20, 2010 10:20 AM expansion cards
F front bezel
G guidelines
connecting external devices, 21
expansion card installation, 124
H hard drive
hot-swap
I iDRAC card
iDRAC Configuration Utility, 83
indicators
installing
K keyboards
L
LCD panel
Index
206
book.book Page 207 Wednesday, January 20, 2010 10:20 AM
M memory
Memory Mirroring memory mode, 92
memory mode
memory modules (DIMMs)
messages
N
NIC
NICs
O optical drive
options
P password
POST
power supplies
processors
R
Index
207
book.book Page 208 Wednesday, January 20, 2010 10:20 AM removing
hard drive from a drive carrier, 112
replacing
S
SAS backplane board
SAS controller card
SAS controller daughter card
SAS RAID controller daughter card
SD card
service-only procedure
slots
startup
support
system board
system cooling
system features
system setup
system setup program
embedded server management options, 73
integrated devices options, 70
Index
208
book.book Page 209 Wednesday, January 20, 2010 10:20 AM
serial communications options, 72
system setup screens
T
troubleshooting
SAS RAID controller daughter card, 187
U
UEFI Boot Manager
USB
internal connector for memory key, 120
USB key
V video
W
warning messages, 60 warranty, 60
wet system
Index
209
book.book Page 210 Wednesday, January 20, 2010 10:20 AM
Index
210
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Dell™ PowerEdge™ R910
- 1 Hardware Owner’s Manual
- 2 Notes, Cautions, and Warnings
- 11 About Your System
- 11 Accessing System Features During Startup
- 12 Front-Panel Features and Indicators
- 14 LCD Panel Features
- 15 Home Screen
- 16 Setup Menu
- 17 View Menu
- 18 Hard-Drive Indicator Patterns
- 19 Back-Panel Features and Indicators
- 21 Guidelines for Connecting External Devices
- 21 NIC Indicator Codes
- 22 Power Indicator Codes
- 23 LCD Status Messages
- 23 Viewing Status Messages
- 24 Removing LCD Status Messages
- 41 System Messages
- 60 Warning Messages
- 60 Diagnostics Messages
- 60 Alert Messages
- 60 Other Information You May Need
- 63 Using the System Setup Program and UEFI Boot Manager
- 63 Choosing the System Boot Mode
- 64 Entering the System Setup Program
- 64 Responding to Error Messages
- 64 Using the System Setup Program Navigation Keys
- 65 System Setup Options
- 65 Main Screen
- 67 Memory Settings Screen
- 68 Processor Settings Screen
- 69 SATA Settings Screen
- 69 Boot Settings Screen
- 70 Integrated Devices Screen
- 71 PCI IRQ Assignments Screen
- 72 Serial Communication Screen
- 73 Embedded Server Management Screen
- 73 Power Management Screen
- 74 System Security Screen
- 76 Exit Screen
- 76 Entering the UEFI Boot Manager
- 77 Using the UEFI Boot Manager Navigation Keys
- 77 UEFI Boot Manager Screen
- 78 UEFI Boot Settings Screen
- 78 System Utilities Screen
- 79 System and Setup Password Features
- 79 Using the System Password
- 81 Using the Setup Password
- 82 Embedded System Management
- 83 iDRAC Configuration Utility
- 83 Entering the iDRAC Configuration Utility
- 85 Installing System Components
- 85 Recommended Tools
- 85 Inside the System
- 87 Front Bezel (Optional)
- 87 Removing the Front Bezel
- 87 Installing the Front Bezel
- 88 System Identification Panel
- 88 Removing the System Identification Panel
- 89 Installing the System Identification Panel
- 89 Opening and Closing the System
- 89 Opening the System
- 90 Closing the System
- 91 System Memory
- 92 General Memory Module Installation Guidelines
- 99 Removing a Memory-Riser Blank
- 100 Installing a Memory-Riser Blank
- 100 Removing a Memory Riser
- 101 Installing a Memory Riser
- 102 Installing Memory Modules
- 105 Removing Memory Modules
- 106 Removing the Memory-Riser Guide
- 107 Installing the Memory-Riser Guide
- 107 Hard Drives
- 108 Removing a Hard-Drive Blank
- 108 Installing a Hard-Drive Blank
- 109 Removing a Hard Drive
- 110 Installing a Hard Drive
- 112 Removing a Hard Drive From a Hard-Drive Carrier
- 113 Installing a Hard Drive Into a Drive Carrier
- 113 Optical Drive
- 113 Removing an Optical Drive
- 115 Installing an Optical Drive
- 116 Cooling Fans
- 116 Removing a Cooling Fan
- 117 Installing a Cooling Fan
- 118 Removing the Cooling Fan Assembly
- 120 Installing the Cooling Fan Assembly
- 120 Internal USB Memory Key
- 123 Integrated NIC Hardware Key
- 124 Expansion Cards and Expansion-Card Riser
- 124 Expansion Card Installation Guidelines
- 126 Installing an Expansion Card
- 128 Removing an Expansion Card
- 129 Installing an Expansion-Card Riser
- 133 Removing an Expansion-Card Riser
- 134 I/O Card
- 134 Removing the I/O Card
- 135 Installing the I/O Card
- 136 iDRAC6 Enterprise Card (Optional)
- 136 Installing an iDRAC6 Enterprise Card
- 138 Removing an iDRAC6 Enterprise Card
- 139 VFlash Media (Optional)
- 139 Installing a VFlash Media Card
- 139 Removing a VFlash Media Card
- 139 Internal Dual SD Module (Optional)
- 139 Removing the Internal Dual SD Module
- 141 Installing the Internal Dual SD Module
- 142 Internal SD Card (Optional)
- 142 Installing an Internal SD Card
- 142 Removing an Internal SD Card
- 143 Integrated Storage Controller Card
- 143 Removing the Integrated Storage Controller Card
- 145 Installing the Integrated Storage Controller Card
- 146 RAID Battery
- 146 Removing a RAID Battery
- 147 Installing the RAID Battery
- 148 Processors
- 148 Removing a Processor
- 152 Installing a Processor
- 154 Power Supplies
- 155 Removing a Power Supply
- 156 Installing a Power Supply
- 157 Removing the Power Supply Blank
- 157 Installing the Power Supply Blank
- 157 System Battery
- 157 Replacing the System Battery
- 159 SAS Backplane
- 159 Removing the SAS Backplane
- 161 Installing the SAS Backplane
- 161 Power Distribution Board
- 161 Removing the Power Distribution Board
- 163 Replacing the Power Distribution Board
- 163 Control Panel Assembly
- 163 Removing the Control Panel Display Module
- 164 Installing the Control Panel Display Module
- 166 Removing the Control Panel Board
- 167 Installing the Control Panel Board
- 168 System Board
- 168 Removing the System Board
- 170 Installing the System Board
- 173 Troubleshooting Your System
- 173 Safety First-For You and Your System
- 173 Troubleshooting System Startup Failure
- 173 Troubleshooting External Connections
- 174 Troubleshooting the Video Subsystem
- 174 Troubleshooting a USB Device
- 175 Troubleshooting a Serial I/O Device
- 175 Troubleshooting a NIC
- 176 Troubleshooting a Wet System
- 177 Troubleshooting a Damaged System
- 178 Troubleshooting the System Battery
- 179 Troubleshooting Power Supplies
- 180 Troubleshooting System Cooling Problems
- 180 Troubleshooting a Fan
- 181 Troubleshooting System Memory
- 183 Troubleshooting an Internal USB Key
- 184 Troubleshooting an Internal SD Card
- 185 Troubleshooting an Optical Drive
- 186 Troubleshooting a Tape Backup Unit
- 186 Troubleshooting a Hard Drive
- 187 Troubleshooting a Storage Controller
- 189 Troubleshooting Expansion Cards
- 190 Troubleshooting the Processors
- 193 Running the System Diagnostics
- 193 Using Online Diagnostics
- 193 Embedded System Diagnostics Features
- 194 When to Use the Embedded System Diagnostics
- 194 Running the Embedded System Diagnostics
- 194 System Diagnostics Testing Options
- 195 Using the Custom Test Options
- 195 Selecting Devices for Testing
- 195 Selecting Diagnostics Options
- 196 Viewing Information and Results
- 197 Jumpers and Connectors
- 197 System Board Jumper
- 198 System Board Connectors
- 200 SAS Backplane Board Connectors
- 201 Disabling a Forgotten Password
- 203 Getting Help