Omron NT11 - 01-2004 Datasheet
Omron NT11 - 01-2004 is a powerful and versatile programmable terminal that offers a range of features to help you control and monitor your industrial processes. With its compact size and high-performance capabilities, the NT11 is ideal for a variety of applications. The NT11 features a 117 x 63 mm effective display area, two RS-232C ports, and a memory link function for easy data transfer. It also supports bar code readers, programming consoles, and has a built-in numeric keypad for convenient data entry.
Advertisement
Advertisement
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by
OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED,
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE
REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH
THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product.
The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use.
Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system.
Note: Do not use this document to operate the Unit.
OMRON Corporation
FA Systems Division H.Q.
66 Matsumoto
Mishima-city, Shizuoka 411-8511
Japan
Tel: (81)55-977-9181
Fax: (81)55-977-9045
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Singapore 239920
Tel: (65)6835-3011/Fax: (65)6835-2711
Authorized Distributor:
Note: Specifications subject to change without notice.
Cat. No. V071-E1-02
Printed in Japan
1003-0.5M
Programmable Terminals
NT11 / NT21
NT21
NT11
Compact Size, High Performance
Superb functionality with a compact screen size
Effective display area
117 x 63 mm
Up to 3,999 screens
High-speed NT Links
Two RS-232C ports
Memory Link
Concentrated functionality
Supports Memory Units
Mathematical functions
NT20S/NT31 data compatibility
31 functional parts
• Recipes
• Alarm lists/histories
• Image library
• Trend graphs
• Analog meters
Upgraded NT Support Tool version (-EV4.7)
• Shares I/O comment data
with CX-Programmer
• Symbol Manager previews
• Copy image library window data
• Individual editing of grouped parts
• Windows XP supported
NT21
Supports RS-232C/422
Adapter (connector)
Bar Code Reader function
Programming Console function
High-speed Host Link Long-lived Backlight
Fully Compatible with NT11S Full Area Access to CS1/CJ1
2
Simplified Ladder Programming
NT11
Password
Screens
Conforms to NEMA4 and IP65
Printout of Production Status
Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report.
(The NT11S has a printer port. One screen only is printed.)
Screen
Line 1
Line 2
Line 3
Plan
200
150
350
Prod.
200
140
350
Bar Graphs can be Displayed
Bar graph displays allow the progress of processes to be checked at a glance.
(The bars are oriented horizontally.)
Integral Numeric Key Pad
The display, numeric keys, and function keys are all integrated into the front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use.
High-speed Host Link
Up to 115,200 bps supported between CS1/CJ1 PLCs.
Key Titles can be Marked on the Function
Key Sheet
Key titles can be marked on the function key sheet in accordance with the applications of the keys: the sheet can be taken out from the side face of the terminal.
The front panel of the terminal has a water-withstanding construction.
Example key titles:
F1
RUN
F2
AUT
F3
MAN.
F4
STOP
Password Screens for Security
Password screens cannot be accessed unless the correct password is entered. This means that the operations that can be performed can be restricted according to the operator.
Long-lived Backlight
Since LEDs are used for the backlight, it is very long-lived and rarely needs to be changed.
Display History Record Helps in Analysis of
Machine Faults
When the display history record function is set as a screen attribute, the time, the screen number, and a comment are recorded in the terminal's memory every time the relevant screen is displayed. This display history can be printed by issuing a print instruction from the host, and is useful for machine fault analysis.
Example printout
No.
1
Time Screen No Screen Comment
11/01-10:00 1 LINE ERROR
2
3
4
11/07-15:33
11/11-13:56
11/14-09:12
15
19
5
MOTOR ERROR
COMPRESSER ERROR
MOTOR ERROR
3
Small Size, Large Screen
The LCD screen is larger than the OMRON NT20S
(increased from 256 x 128 dots to 260 x 140 dots), but the external dimensions and panel cut-out size are the same.
Larger screen
Long, Maintenance-Free Life (50,000 h)
Conforms to International Standards
The NT21 conforms to the EC Directives, as well as UL, cULus (Class 1 Div2), and C-Tick.
The front panel has an enclosure rating equivalent to IP65F.
System and screen data can be stored in
NT21 Flash Memory.
4
Two RS-232C Ports
Two RS-232C ports in the NT21 (compared with one in the
NT20S) enable simultaneous connection of a PLC, Bar
Code Reader, and NT Support Tool (connectable to serial port A only).
NT Support Tool
(screen creation/transfer)
NT21
RS-232C
RS-232C
PLC (host)
Plenty of Capacity for Saving Graphic Screens
With 512 Kbytes of memory capacity, there is more than ample space for storing screen data.
Abundant graphic screen storage
Versatile Communications
In addition to the Host Link and 1:1 NT Link communications, the NT21 supports high-speed 1:N NT
Links and Memory Link communications.
Recipe Function
Parts tables on the PT screen can be used to set multiple word data in records, which can then be written to the PLC by a simple PT touch panel operation. For example, the setting parameters for separate models can be edited on the PT, then written to or read from the PLC.
Alarm List/History(*)
An alarm message can be displayed in response to
PLC bit status, and the content and time of the message can be stored as an alarm history.
*C500-BAT08 Battery
(sold separately) required.
Programming Console Function
The NT21 is equipped with many of the same functions as the SYSMAC PLC Programming Console.
NT21
Programming Console function
PLC (host)
RS-232C
PLC (host)
NT21 NT21
RS-232C
High-speed
1:N NT Links
Memory
Link
RS-232C
Personal computer
(host)
Mathematical Functions
Up to 256 math equations can be stored in the PT processing table to allow automatic PT processing, and the results can be written to the numeral memory table or other destinations. This makes it possible to perform scaling and other mathematical operations automatically in the PT.
Enhanced Editing Functions
•I/O comments in the I/O tables of the CX-Programmer can be used directly.
NT Support Tool CX-Programmer
CX-Server
I/O comment data
I/O comments for designated PLC addresses can be used directly, with no need for CSV file conversion.
•Symbol Manager previews are supported.
This function makes it possible to preview symbols
(parts created from graphics data).
•Parts can be copied by drag & drop operations of image, library, or mark data.
•The properties of grouped parts can be edited without having to ungroup them.
•Because NT20S and NT31 screen data is compatible with the NT21, existing software assets can be utilized to greatly reduce the number of design steps.
Note: Some data revisions may be required due to size differences.
•Windows XP supported.
Comparison with the NT11
Basic performance
Display elements
Special functions
Communications
Model
Dimensions
Resolution
Effective display area
Display color
Panel cut-out size (W x H)
Max. number of registered screens
Screen data capacity
Function keys
Other Keys
Rectangles, polygons, arcs, sectors
Painting out
Image/library displays
Analog meters
Trend graphs
Broken line graphs
Alarm lists/histories
Recipes
Interlocks
Mathematical
Function
Programming
Console function
High-quality font
Memory Unit
Backlight service life
Memory Links
NT11 NT11S
218 x 113 x 38.2 mm (H x W x D)
160 x 64 dots (4.24 inches)
100 x 40 mm
Black & white (with Yellow mode)
204.2 x 99.8 mm
250
32 KB
4
Numeric Keys, Cursor Keys, Function Keys
None
None
None
None
None
None
None
None
None
None
None
None
None (Emergency transfer mode)*
50,000 hours min.
10,000 hours min.
None
260 x 140 dots
(5.2 inches)
117 x 63 mm
NT21 NT20S
190 x 110 x 53.5 mm (H x W x D)
256 x 128 dots
(4.91 inches)
112 x 56 mm
Black & white (with blue mode)
178.5 x 100.5 mm
3,999
512 KB
None
None
Supported
Supported
256 positions per screen
50 positions per screen
1 position per screen
1 position per screen
4 positions per screen
1 position per screen
Supported
Math equations: Max. 256
(arithmetic functions, logic operations, bit manipulations, comparison operations)
(Executes functions equivalent to C200H-PR027 and CS1 Programming
Consoles.)
Supported
Supported
50,000 hours min.
Supported
500
96 KB
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
10,000 hours min.
Via RS-232C communications
Bar Code Reader connection
Host Link Speed
None Supported None
Up to 115,200 9,600/19,200 9,600/19,200 9,600/19,200
* Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation.
5
6
NT11 General Specifications
Item Specification
24 VDC
Allowable power
Noise resistance
Vibration resistance
Conforms to IEC61000-4-4, 2K (power lines)
10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with
9.8 m/s 2 acceleration for 30 min in each of X, Y, and Z directions
147 m/s 2 3 times in each of X, Y, and Z directions Shock resistance
Ambient operating temperature
0 to +50˚C
Ambient operating humidity
Operating environment
35 to 85% RH (with no condensation)
No corrosive gasses.
Storage temperature –20 to +70˚C (with no freezing)
Enclosure ratings
Weight
Front panel: Equivalent to IP65, NEMA4
1.0 kg max.
Display/Panel Specifications
Note: In order to improve the performance of displays, liquid crystal devices may be ch
Item
Display screen
Indicators
Switch
Dot matrix of STN liquid
Specification
• Number of dots: 160 x 64
• Effective display area:
100 x 40 mm
• Life expectancy: 50,000 hours
minimum
• View angle (left/right direction):
±20˚
Backlight
• LED
• Life expectancy: 50,000 hours
minimum
• Automatic turn-off: can be set
to turn off in 10 minutes or
1 hour, or to remain on.
• RUN indicator (Green LED): Lit during operation
• Life expectancy: 1 million operations minimum
Display Capacity
Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
Item
Display characters
Specification
Normal characters (8 x 16 dots): Alphanumerics and symbols
Marks (8 x 16 dots): User-defined, 64 max.
Number of characters displayed
Normal-size: 20 horizontally x 4 lines vertically max.
Double width
Character string displays
Numeral
Display elements
Graph
8 positions per screen
8 positions per screen
4 positions per screen
Numeral settings
Screen attributes history
Order of frequency, 256 screens
Ensures security: screens for which this attribute is set can only be displayed if the correct password is input.
Four items per screen screen
Menu screen
Screen types
Max. number of registered screens
Screen registration method
Screen saving method
Normal screen: Displays screen registered as normal.
250
Transfer screen data created using an IBM PC/AT personal computer to the PT.
Saved to flash memory: 32 KB (downloading method)
Special Features
Item
Printing function
Specification
Printing of display history data
Printing of daily reports (printing format registered by the users)
Maintenance functions
• Simple communications confirmation.
NT11 Product Configurations
Terminal*
Product
Host link direct connection,
NT link method
Support Software
Function key sheet
Specification
Ten-key type (frame color: beige)
Ten-key type (frame color: black)
CD-ROM (for Windows 95, 98,
Me, XP, NT, 2000)
10 sheets for replacement for beige
10 sheets for replacement for black
Model
NT11-SF121-EV1
NT11-SF121B-EV1
NT-ZJCAT1-EV4
NT11-CKF01
NT11-CKF01B
*
and a flash ROM that downloads the system program.
* Connecting cables with the PLC and NTST are the same as those for the NT21.
Please refer to the next page.
Outside Dimensions
203
Rear face
218
Panel Plate thickness: 1.6 to 4.8 mm
Recommended panel cutout:
204.2
+0.5
0
98.
8 +0.5
0
38.2
98
80.5
NT21 General Specifications
Item Specification
±15%
Power consumption
Noise resistance Conforms to IEC61000-4-4. Power supply line: 2 kV
Vibration resistance 2 acceleration,
Peak acceleration 15 G,
Shock resistance
Ambient operating temperature
˚
– ˚
Ambient operating humidity
˚C)
Dimensions
Enclosure ratings
Weight
190 x 110 x 53.5 mm (W x H x D)
(thickness inside panel: 49.0 mm)
Front panel operating section: Equivalent to IP65F, NEMA 4.*
0.6 kg max.
* Usage may not be possible in places where the unit would be exposed to oil for long periods.
Display Capacity
Item
Fixed displays
(Graphics:
Graphics
Marks rectangles, circles,
Specification
With overlapping screens, the total is
524,280 per screen
Display elements
Character string displays
Graph displays
Analog meters
Trend graphs
Broken line graphs
256 positions per screen, max.
1,024 display elements for overlapping screens
50 positions per screen, capable of displaying signs and percentages
50 positions per screen, capable of displaying signs and percentages
One frame per screen, 50 items per frame
(8 items max. for data logging)
One frame per screen, 256 items per frame,
260 points per item
Lamps 256 positions per screen
Image library images 256 positions per screen
Touch switches
256 positions per screen
26 positions per screen
256 positions per screen
Total of 256 positions for both numerical and thumbwheel settings
Screen types
Recipes
Normal screens
Programming
Console screen
One position per screen
Displays screens registered as normal
Windows
A maximum of eight screens can be displayed overlapping each other.
Up to three window screens can be displayed.
Display history screens Order of occurrence (1,024 screens max.), order of frequency (255 times max.)
System startup screen
Displayed when powering ON (or resetting ) the PT, and when switching to RUN mode.
Emulates PLC Programming Console functions, capable of being called from RUN mode.
Screen attributes
Buzzer, display history, normal background colors, backlight mode, local windows
Max. number of
3,999
Number of screens
Screen number
0: No display
1 to 3999: User registered screens
(normal, overlapping, windows)
9000:
9001:
9002:
9020:
System startup screen
Display history screens, order of occurrence
Display history screens, order of frequency
Programming Console screen
Screen registration method
Saving screen data
9999: Return to previous screen designation
By transferring screen data from the NT Support Tool to the PT via serial communications
By mounting the Memory Unit and downloading
(automatic/manual transfer) data to the PT
Flash memory (PT internal image memory)
Display Specifications
Display panel
Backlight
Item
Display device
Number of dots (resolution)
Effective display area
Viewing angle
Display color
Service life
(white cold cathode tube)
Automatic turn-OFF
Service life
Replacement
Specification
Monochrome STN LCD
260 dots horizontally x 140 dots vertically
117 mm horizontally x 63 mm vertically
˚ ˚
Black & white (with blue mode)
50,000 hours min. (until contrast reduced to 50%)
Can be set to turn OFF in 1 to 255 min or to remain ON with screen saver
50,000 hours min. (at room temperature, until brightness is reduced to 50%)
Non-replaceable
Panel Specifications
Touch panel
Item
Number of switches
Input
Life expectancy
Specification
91 (13 horizontally x 7 vertically)
Pressure-sensitive
1 N max.
1 million operations min.
External Interface Specifications
Communications method
NT Support Tool
Host Link
1:1 NT Link
PLC
1:N NT Links
NT Link, PT Programming Console function
SBC/personal computer Memory Links
Bar Code Reader
Serial port A
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Serial port B
Not supported
Supported
Supported
Supported
Supported
Supported
Not supported
* Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector), which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.)
NT21 Standard Models
Product
NT21
Programmable
Terminal
Monochrome STN
Support Tooll Windows 95, 98, Me, NT, or 2000
For screen transfer
Specification
Frame color: beige
CD-ROM
PT: 9-pin
PLC: 9-pin
Cable length: 2 m
Cables
Options
Model number
NT21-ST121-E
NT-ZJCAT1-EV4
XW2Z-S002
XW2Z-200T
For
PLC connection
PT: 9-pin
PLC: 25-pin
Cable length: 2 m
Cable length: 5 m
XW2Z-200S
XW2Z-500S
PT: 9-pin
PLC: Mini-peripheral
Reflection Protective Sheets
Chemical-resistive Cover
Cable length: 5 m XW2Z-500T-2
Display area only (5 sheets)
Silicon cover
NT20M-KBA04
NT20S-KBA01
Battery
Memory Unit
For alarm lists/histories
For screen and system data transfer
C500-BAT08
NT-MF161
RS-232C/422A Adapter
Connector Kit
NS-AL002
XM2S-0911-S003
Dimensions
178
53.5
100 122
110
4.5
39 min.
142
190
Panel thickness: 1.6 to 4.8 mm
15.5
178.5 +0.5
/ – // – 0 mm (W x H)
19.5
52.5
28
Download
Advertisement