Ariston CLAS HE R 12 User manual


Add to my manuals
8 Pages

advertisement

Ariston CLAS HE R 12 User manual | Manualzz
User Manual
Gas fired condensing wall hung boiler
G.C.N : 41-116 - 30 (12 kW)
G.C.N : 41-116 - 31 (18 kW)
G.C.N : 41-116 - 32 (24 kW)
Country of destination GB, IE
CLAS HE R 12
CLAS HE R 18
CLAS HE R 24
user manual
Dear Customer,
Thank you for choosing an ARISTON boiler.
We guarantee that your boiler is a reliable and technically sound product. This manual provides detailed
instructions and recommendations for the correct use of the appliance.
Remember to keep this manual in a safe place for future reference i.e. by the boiler.
Your local MTS Servicing Centre is at your complete disposal for all requirements.
The installation and first ignition of the boiler
must be performed by qualified personnel in
compliance with current national regulations
regarding installation, and in conformity with
any requirements established by local authorities
and public health organisations.
All CORGI registered installers carry a CORGI
ID card, and have a registration number. Both
should be recorded in the Benchmark Log Book.
You can check your installer is CORGI registered
by calling CORGI directly on:- 0800 915 0485
After the boiler has been installed, the installer
must ensure that the end user receives the
declaration of conformity and the operating
manual, and should provide all necessary
information as to how the boiler and the safety
devices should be handled.
This appliance is designed to produce central heating
for domestic use only.
It should be connected to a heating system and a
distribution network for domestic hot water, both of
which must be compatible with its performance and
power levels.
The use of the appliance for purposes other than
those specified is strictly forbidden. The manufacturer
cannot be held responsible for any damage caused
by improper, incorrect and unreasonable use of
the appliance or by the failure to comply with the
instructions given in this manual.
Installation, maintenance and all other interventions
must be carried out in full conformity with the
governing legal regulations and the instructions
provided by the manufacturer. Incorrect installation
can harm persons, animals and possessions;
the manufacturing company shall not be held
responsible for any damage caused as a result.
In the event of any maintenance or other structural
work in the immediate vicinity of the ducts or flue
gas exhaust devices and their accessories, switch
the appliance off by switching the external bipolar
switch to the “OFF” position and shutting off the gas
valve.
When the work has been completed, ask a qualified
technician to check the efficiency of the ducting and
the devices.
If the boiler should be out of use for a prolonged
period, it is recommended that the electrical power
supply be disconnected and that the external gas
cock be closed. If low temperatures are expected,
the boiler and system pipe work should be drained
in order to prevent frost damage.
Turn the boiler off and turn the external switch “OFF”
to clean the exterior parts of the appliance.
Do not allow children or inexperienced persons to
use the appliance without supervision.
CE labelling
The CE mark guarantees that the appliance conforms
to the following directives:
- 90/396/CEE
relating to gas appliances
- 2004/108/CEE
relating to electromagnetic compatibility
- 92/42/CEE
relating to energy efficiency
- 2006/95/CEE
relating to electrical safety
The Benchmark Scheme
MTS is a licensed member of the Benchmark Scheme
which aims to improve the standards of installation
and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
Please ensure that the installer has fully completed
the Benchmark Checklist on the inside back pages
of the installation instructions supplied with the product and that you have signed it to say that you have
received a full and clear explanation of its operation.
The installer is legally required to complete a commissioning checklist as a means of complying with
the appropriate Building Regulations (England and
Wales).
All installations must be notified to Local Area Building Control either directly or through a Competent
Persons Scheme. A Building Regulations Compliance
Certificate will then be issued to the customer who
should, on receipt, write the Notification Number on
the Benchmark Checklist.
This product should be serviced regularly to optimise
its safety, efficiency and performance. The service engineer should complete the relevant Service Record
on the Benchmark Checklist after each service.
The Benchmark Checklist may be required in the
event of any warranty work and as supporting documentation relating to home improvements in the
optional documents section of the Home Information Pack.
user manual
GUARANTEE
The manufacturer’s guarantee is for 2 years from the date of purchase. The guarantee is invalidated if
the appliance is not installed in accordance with the recommendations made herein or in a manner not
approved by the manufacturer. To assist us in providing you with an efficient after sales service, please
return the guarantee registration card enclosed with the boiler without delay.
Ariston only obligation under the guarantee will be to repair or replace the faulty appliance at Ariston
discretion. This will be carried out where the fault arises from defects within the appliance, caused either
by material or workmanship of the manufacturer.
This guarantee does not protect malfunction or damage arising from incorrect installation, commissioning
or maintenance procedures as laid out in the installation and servicing manual, inefficient flue system, poor
or incorrect electricicty, wrong gas supply or pressure, tampering by inexperienced persons and any other
cause not directly due to manufacture.
MTS (GB) Limited cannot accept responsibility for any cost arising from repair or maintenance carried out
by any third party.
Repair under the guarantee does not affect the expiry date of the guarantee. The guarantee on parts and
appliances which are exchanged ends when the guarantee on the original appliance expires.
This guarantee does not affect your statutory rights.
You must have your boiler serviced at the end of the first year to validate your guarantee for the second
year and ensure the Benchmark Service Interval Record is completed.
Safety regulations
Key to symbols:
Failure to comply with this warning implies the
risk of personal injury, in some circumstances
even fatal.
Failure to comply with this warning implies the
risk of damage, in some circumstances even
serious, to property, plants or animals.
Do not perform operations which involve
opening the appliance.
Electrocution from live components.
Personal injury caused by burns due to overheated components, or wounds caused by
sharp edges or protrusions.
Do not perform operations which involve
removing the appliance from its installation
space .
Electrocution from live components.
Flooding caused by water leaking from disconnected piping.
Explosions, fires or intoxication caused by gas
leaking from disconnected piping.
Do not damage the power supply cable.
Electrocution from live uninsulated wires.
Do not leave anything on top of the appliance.
Personal injury caused by an object falling off
the appliance as a result of vibrations.
Damage to the appliance or items underneath
it caused by the object falling off as a result of
vibrations.
Do not climb onto the appliance.
Personal injury caused by the appliance falling.
Damage to the appliance or any objects underneath it caused by the appliance falling
away from its installation space.
Do not climb onto chairs, stools, ladders or
unstable supports to clean the appliance.
Personal injury caused by falling from a height
or cuts (step ladders shutting accidentally).
Do not attempt to clean the appliance
without first switching it off and turning the
external switch to the OFF position.
Electrocution from live components.
Do not use insecticides, solvents or aggressive detergents to clean the appliance.
Damage to plastic and painted parts.
Do not use the appliance for any use other
than normal domestic use.
Damage to the appliance caused by operation
overload.
Damage caused to objects treated inappropriately.
Do not allow children or inexperienced individuals to operate the appliance.
Damage to the appliance caused by improper
use. If you detect a smell of burning or smoke coming from the appliance, disconnect
it from the electricity supply, turn off the
main gas valve, open all windows and call
for assistance.
Personal injury caused by burns, smoke inhalation, intoxication.
If there is a strong smell of gas, turn off the
main gas valve, open all windows and call
for assistance.
Explosions, fires or intoxication.
user manual
Control panel
1
2
12
3
11
10
9
4
5
8
7
6
Legend :
1. Display
2. Reset button
3. Red indicator lockout light
4. Button _
5. Temperature regulation knob
6. Esc button
Ignition procedure
Press the ON/OFF button on the control panel to
switch on the boiler. The display shows:
The first figure indicates the operating mode:
0 - Stand -by,
C - Heating request
c
- Heating post-circulation
F
- Anti-freeze protection enabled
The second and third figures indicate:
- the flow temperature when no heating requests
have been made
- the flow temperature in central heating
mode
- the flow temperature in anti-freeze mode.
7. Menu / OK button (Programming key)
8. Button +
9. ON/OFF button / Green indicator ON/OFF
10. Blue indicator burner ON
11. Green indicator Auto function
12. Auto button (To activate
Thermoregulation)
user manual
Adjusting the heating
It is possible to set the temperature of the heating water by adjusting the knob 5. By placing the
indicator somewhere between min. and max. A temperature may be obtained which varies from
approximately 40°C to about 82°C.
Switching off the heating
To switch off the heating mode turn the knob 5 to the position
position
. Or set the timer to the off
Stand by
To switch off the boiler press the ON/OFF button 9.
Switch off the boiler completely by switching the external electrical switch to the OFF position.
user manual
Appliance shut-off conditions
The boiler is protected from malfunctions by
means of internal checks performed by the
electronic P.C.B., which stops the boiler from
operating if necessary. In the event of the boiler
being shut off in this manner, a code appears
on the control panel display which refers to the
type of shut-off and the reason behind it.
Two types of shut-off may occur:
Safety shut-off
This type of error is “volatile”, which means
that the boiler starts up again
automatically as soon as the
problem which caused the shutoff is removed. The display will
flash ”Err” and the error code.
As soon as the cause of the shut-off disappears,
the boiler starts up again and continues to
operate normally.
While the boiler is shut off for safety reasons, it is
possible to attempt to restore normal operation
by switching the appliance off and on again
using the ON/OFF button on the control panel.
If the boiler still indicates a safety shut-off, switch
it off. Make sure the external electric switch is in
the OFF position, close the gas tap and contact
a qualified technician.
Operation shutdown
This type of error is “non volatile”, which means
that it is not removed automatically. The display
will flash Err and the error code and the red
.
led lights up “3”
In this case the boiler does not restart
automatically, but it may be reset by pressing
the
button 2. If the problem manifests
itself again after several attempts to reset the
appliance, contact a qualified technician.
IMPORTANT
IF THIS SHUTDOWN OCCURS FREQUENTLY,
CONTACT AN AUTHORISED SERVICE CENTRE
FOR ASSISTANCE. FOR SAFETY REASONS, THE
BOILER WILL ALLOW A MAXIMUM OF 5 RESET
OPERATIONS TO TAKE PLACE IN 15 MINUTES
(INDIVIDUAL PRESSES OF THE
BUTTON).
Operation shutdown error table
Display
1 01
5 01
1 03
1 04
1 05
1 06
1 07
3 05
3 06
3 07
Description
Overheating
No flame detection
Insufficient circulation
P.C.B error
P.C.B error
P.C.B error
Anti-frost Device.
The anti-frost function acts on the central heating flow temperature probe, independently
from other settings, when the electrical supply
is turned on.
If the primary circuit temperature falls below
8°C the pump will run for 2 minutes.
After the two minutes of circulation (fixed) the
boiler will check the following:
a) if the flow temperature is > 8°C, the pump
stops;
b) if the flow temperature is between 4 and 8°C,
the pump will run for another two minutes;
c) if the flow temperature is < 4°C, the burner
will fire at minimum power until the temperature reaches 33°C, the burner will go off
and the pump will continue to run for two
minutes.
The anti-frost device activates only when (with
the boiler operating correctly):
- the boiler is electrically powered,
- there is a supply of gas.
user manual
Auto button - Temperature adjustment
activation
The AUTO function enables boiler operation to
be adapted to environmental conditions and
to the type of system it is installed on.
Comfortable temperature is reached inside
the room in the quickest way possible, without
wasting money, energy or efficiency, while
substantially reducing the amount of wear
experienced by the components.
Your installer will advise you on the devices
connectable to the boiler and will program
according to the system.
In normal boilers the water temperature inside
the heating elements is usually set to a high
value (70-80°C), thereby ensuring effective
heating during the few really cold winter days.
It then becomes excessive on less cold days
(of which there are many) more typical of
the autumn and winter seasons. This leads to
excessive room heating after the thermostat
has been switched off, resulting in energy
waste and uncomfortable conditions inside
the room.
The AUTO function “takes control” of the boiler
and selects the best operating regime based
on environmental conditions, external devices
connected to the boiler and the performance
required. It constantly decides at which power
level to operate based on the environmental
conditions and the room temperature
required.
Change of gas type
Our boilers are designed to function either with
Natural Gas (methane) or L.P.G. gas. If you need
to change from one gas to the other, one of our
Authorised Service Centres must be contacted
to convert the appliance.
Maintenance
Schedule an annual maintenance check-up for
the boiler with a competent person.
Correct maintenance generally results in
savings in the cost of running the system.
Failure to arrange an annual service for the appliance will invalidate the second year of the
manufacturer’s guarantee.
MTS (GB) Limited
MTS Building
Hughenden Avenue
High Wycombe
Bucks HP13 5FT
Telephone: (01494) 755600 Fax: (01494) 459775
Internet: www.ariston.co.uk
E-mail: [email protected]
Technical Advice: 0870 241 8180
Customer Service: 0870 600 9888
Professional Team Limited
Suites 9 & 10, Plaza 256
Blanchardstown Corporate Park 2
Ballycoolin
Dublin 15
Telephone: (01) 899 1500
Fax: (01) 899 1501
Internet: www.mtsgroup.com/ie
E-mail: [email protected]
Technical Advice: (01) 437 0121
Customer Service: (01) 437 0121