FDC-HKXR 20. INVERTER DRIVEN MULTI-INDOOR UNIT HEAT RECOVERY CLIMATE CONTROL SYSTEM Simultaneous heating & Cooling 3 Pipe System ( ) (OUTDOOR UNIT) Alternative refrigerant R407C use models FDCP2001HKXRE2, 2501HKXRE2 (INDOOR UNIT) FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTWJ28HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 90HKXE2B 112HKXE2B 140HKXE2B FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDRJ22HKXE2 28HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDUMJ36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDEJ36HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 112HKXE2B 140HKXE2B FDKJ22HKXE2 28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 935 FDC-HKXR CONTENTS 20.1 GENERAL INFORMATION ...................................................................... 937 20.1.1 Specific features ............................................................................... 937 20.1.2 How to read the model name ........................................................... 939 20.1.3 Table of models ................................................................................. 939 20.1.4 Table of indoor units panel (Optional) ............................................ 939 20.2 SELECTION DATA................................................................................... 940 20.2.1 Specifications .................................................................................... 940 20.2.2 Range of usage & limitations ........................................................... 966 20.2.3 Exterior dimensions.......................................................................... 967 20.2.4 Exterior appearance.......................................................................... 993 20.2.5 Piping system .................................................................................... 996 20.2.6 Selection chart .................................................................................. 997 20.2.7 Characteristics of fan ....................................................................... 1011 20.2.8 Noise level ......................................................................................... 1016 20.3 ELECTRICAL DATA ................................................................................ 1022 20.3.1 Electrical wiring ................................................................................ 1022 20.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER ........... 1032 20.5 APPLICATION DATA ............................................................................... 1045 20.5.1 Installation of indoor unit ................................................................. 1046 20.5.2 Installation of the remote controller (Optional Parts) .................... 1046 20.5.3 Installation of outdoor unit............................................................... 1046 20.5.4 Refrigerant piping ............................................................................. 1051 20.5.5 Electrical wiring ................................................................................ 1058 20.5.6 Test run .............................................................................................. 1066 20.6 MAINTENANCE DATA............................................................................. 1068 20.6.1 Diagnosis of Microcomputer circuit ................................................ 1068 936 FDC-HKXR 20.1 GENERAL INFORMATION 20.1.1 Specific features (1) Fuzzy control (a) Response speed and stability are enhanced. • The system automatically controls changes of return air temperature, set temperature and room temperature according to the fuzzy control. • The system response speed, can keep room temperature constant, and can adjust room temperature to set temperature quickly. Inverter Hz Set temp. Temp. difference Gradient of temp. operation FUZZY operation Temp. (Return air thermistor) E.E.V. pulse (b) Elimination of temperature irregularity as the time of operation ON/OFF control • The system finely controls the compressor to room temperature according to the temperature sensor, air conditions room temperature consistently and improves cooling or heating feeling in each room (or minimize influence of shutdown in other room). (2) Super lynk system • Non polar 2-core signal wires for indoor, outdoor units by means of the automatic polarity selection. • In addition, the max. 48 units can be controlled with a pair of signal wires. The high speed transmission method same as the computer network system [start up of 48 units can be completed within a few seconds by the determination of operation mode and the start of operation]. • As separate power supplies for the indoor and the outdoor units are employed, a pair of 2 signal wires only are required for the inter connecting wiring of indoor and outdoor units regardless of the number of units so that the installation work can be simplified, the cost of wiring work can be curtailed and causes of wiring error can be minimized. 937 FDC-HKXR (3) Installation of automatic address setting function • The address setting method are divided into three types according to wiring method: “Automatic Address Setting,” “Remote control Address Setting.” and “Manual Address Setting.” In case of the Automatic Address Setting, no address needs be set as usual. (4) Connectable indoor capacity Capacity from 50% to 130% is possible. • FDCP2001HKXRE2 Number of connectable units: 1 to 8 units Connectable capacity: 11000 ~ 29200 W • FDCP2501HKXRE2 Number of connectable units : 1 to 8 units Connectable capacity: 13200 ~ 37100 W (5) Cooling opetation down to -5˚C outdoor temperature (6) Indoor units are available with 9 capacities, in 9 types and 54 models. ● 9 capacities…22(0.8 HP), 28(1 HP), 36(1.25 HP), 45(1.6 HP), 56(22 HP), 71(2.5 HP), 90(3.2 HP), 112(4 HP) and 140(5 HP). ● 9 types…Ceiling recessed type(FDT), 2-way outlet ceiling recessed type(FDTW), 1-way outlet ceiling recessed type(FDTS), Cassetteria type(FDR), Satellite ducted type(FDUM), Ceiling suspension type(FDE), Wall mounted type(FDK), Floor standing exposed type(FDFL) and Floor standing hidden type(FDFU). (7) Vertical blow or horizontal blow type can be selected for the outdoor unit. horizontal blow Standard Vertical blow Using an adapter (Optional) (8) Long piping design offeres One way piping length of 100 m ● Indoor and outdoor units can have a level difference of up to 50 m, with a one way piping length of up to 100 m. This is the topclass long piping design in the industry. A level difference of as much as 15 m between indoor units ensures that the system can meet a wide variety of air conditioning requirements in any building. (9) Layout free refrigerant piping The branch type piping makes the system flexible enough to satisfy any layout plan on the floor or in a room. (10) Improvement of serviceability (a) Failures of indoor unit and outdoor units are shown on the liquid crystal display on the remote controller. ● Failures of indoor unit and outdoor units can be checked by remote controller. (b) Easy checking of outdoor inspection LED. ● The LED can be checked without removing the service panel, and faulty units can be easily indentified out of several units. 938 FDC-HKXR 20.1.2 How to read the model name Example: FDC P 2001 H KXR E 2 CE marking model Application power source...See the specifications Multi KXR series Heat pump type Nominal capacity R407C models Model name Indoor unit : FDT, FDTW, FDTS, FDR, FDUM FDE, FDK, FDFL, FDFU Outdoor unit : FDC 20.1.3 Table of models Capacity Model 22 28 36 45 56 71 90 112 140 Ceiling recessed type (FDT) 2-way outlet ceiling recessed type (FDTW) 1-way outlet ceiling recessed type (FDTS) Cassetteria type (FDR) Stellite ducted type (FDUM) Ceiling suspension type (FDE) Wall mounted type (FDK) Floor standing exposed type (FDFL) Floor standing hidden type (FDFU) Outdoor units tobe combined FDC FDCP224HKXRE2 (8 Horse Power) FDCP280HKXRE2 (10 Horse Power) 20.1.4 Table of indoor units panel (Optional) Model FDT FDTW (Standard type) FDTW (Attachment of ceiling material type) FDTS FDR (Silent type) FDR (Canvas type) Parts Model Capacity:28,36,45,56, 71,90,112,140 Capacity:28,45,56 Capacity:71,90 Capacity:112,140 Capacity:28,45,56 Capacity:71,90 Capacity:112,140 Capacity:22,28,36,45 Capacity:71 Capacity:22,28,45,56 Capacity:71,90 Capacity:112,140 Capacity:22,28,45,56 Capacity:71,90 Capacity:112,140 T-PSA-32W-E TW-PSA-22W-E TW-PSA-32W-E TW-PSA-42W-E TW-PSB-28W-E TW-PSB-38W-E TW-PSB-48W-E TS-PSA-26W-E TS-PSA-36W-E R-PNLS-26W-E R-PNLS-36W-E R-PNLS-46W-E R-PNLC-26W-E R-PNLC-36W-E R-PNLC-46W-E 939 FDC-HKXR 20.2 SELECTION DATA 20.2.1 Specifications (1) Indoor unit (a) Ceiling recessed type (FDT) Models FDTJ28HKXE2, 36HKXE2 Models Item FDTJ28HKXE2(3) FDTJ36HKXE2(3) Nominal cooling capacity*1 W 2800 3600 Nominal heating capacity*2 W 3200 4000 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight Hi: 37 Me: 34 Lo: 33 mm Unit:260 840 840 Panel:30 950 950 Unit:24 Panel:7 kg Refrigerant equipment Heat exchanger Louver fine & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Turbo fan 1 Motor W 17 1 Starting method Line starting Air flow(Standard) CMM Hi: 12 Me: 10 Lo: 9 Fresh air intake Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 6.35(1/4"), Gas line: 12.7(1/2") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas line) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTJ28,36 type Panel Part No. T-PSA-32W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 940 FDC-HKXR Models FDTJ45HKXE2, 56HKXE2, 71HKXE2 Models FDTJ45HKXE2(3) FDTJ56HKXE2(3) W 4500 5600 7100 W 5000 6300 8000 Item 1 Nominal cooling capacity* Nominal heating capacity*2 Power source FDTJ71HKXE2(3) 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight Hi: 38 Me: 35 Lo: 34 mm Unit:260 kg Hi: 40 Me: 38 Lo: 36 840 840 Panel:30 950 950 Unit:24 Panel:7 Refrigerant equipment Heat exchanger Louver fine & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Turbo fan Motor 1 20 1 W 25 1 Starting method Line starting Air flow(Standard) CMM Hi: 15 Me: 12 Lo: 10 Fresh air intake Hi: 16 Me: 13 Lo: 11 Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 6.35(1/4") Gas line: 12.7(1/2") mm(in) Liquid line: 9.52(3/8") Gas line: 15.88(5/8") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTJ45,56,71 type Panel Part No. T-PSA-32W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 941 FDC-HKXR Models FDTJ90HKXE2, 112HKXE2, 140HKXE2 Models FDTJ90HKXE2(3) FDTJ112HKXE2(3) W 9000 11200 14000 W 10000 12500 16000 Item 1 Nominal cooling capacity* Nominal heating capacity*2 Power source FDTJ140HKXE2(3) 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight Hi: 42 Me: 40 Lo: 38 Unit: 260 Panel:30 mm kg 840 950 Hi: 49 Me:46 Lo: 42 840 950 Unit: 320 Panel:30 Unit:24 Panel:7 Hi: 50 Me: 47 Lo: 45 840 950 Unit:28 Panel:7 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Turbo fan Motor Unit:30 Panel:7 1 80 1 50 1 W 840 950 Starting method 130 1 Line starting Air flow(Standard) Hi: 21 Me: 15 Lo: 12 CMM Hi: 28 Me: 24 Lo: 21 Fresh air intake Hi: 30 Me: 26 Lo: 22 Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8") Gas line: 15.88(5/8") mm(in) Liquid line: 9.52(3/8") Gas line: 19.05(3/4") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTJ90,112,140 type Panel Part No. T-PSA-32W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 942 FDC-HKXR (b) 2-way outlet ceiling recessed type (FDTW) Models FDTWJ28HKXE2B, 45HKXE2B, 56HKXE2B Models Item FDTWJ28HKXE2B(3) FDTWJ45HKXE2B(3) FDTWJ56HKXE2B(3) Nominal cooling capacity*1 W 2800 4500 5600 Nominal heating capacity*2 W 3200 5000 6300 Power source 1 Phase 220/240V 50Hz Noise level dB(A) Exterior dimensions Height Width Depth Net weight Hi: 39 Me:36 Lo: 33 mm Unit:280 817 620 kg Panel:8 1055 680 Unit:19 Panel:7 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Turbo fan 1 Motor 30 1 W Starting method Line starting Air flow(Standard) CMM Hi: 14 Me: 12 Lo: 10 Fresh air intake Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 6.35(1/4") Gas line: 12.7(1/2") mm(in) Liquid line: 9.52(3/8") Gas line: 15.88(5/8") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTWJ28,45,56 type Panel Part No. Standard type Attachment of ceiling material type TW-PSA-22W-E TW-PSB-28W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 943 FDC-HKXR Models FDTWJ71HKXE2B, 90HKXE2B Models FDTWJ71HKXE2B(3) Item FDTWJ90HKXE2B(3) Nominal cooling capacity*1 W 7100 9000 Nominal heating capacity*2 W 8000 10000 dB(A) Hi: 41 Me: 38 Lo: 35 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight mm Hi: 41 Me: 39 Lo: 36 Unit:330 1054 kg 620 Panel:8 1300 680 Unit:26 Panel:9 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillay tube Air handling equipment Fan type & Q'ty Turbo fan 1 Motor 35 1 W 40 1 Starting method Line starting Air flow(Standard) CMM Hi: 16 Me: 13 Lo: 11 Hi: 19 Me: 16 Lo: 12 Fresh air intake Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8"),Gas line: 15.88(5/8") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTWJ71,90 type Panel Part No. Standard type Attachment of ceiling material type TW-PSA-32W-E TW-PSB-38W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 944 FDC-HKXR Models FDTWJ112HKXE2B, 140HKXE2B Models FDTWJ112HKXE2B(3) Item FDTWJ140HKXE2B(3) 1 Nominal cooling capacity* W 11200 14000 Nominal heating capacity*2 W 12500 16000 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight Hi: 44 Me: 41 Lo: 38 mm Hi: 45 Me: 42 Lo: 39 Unit:345 1524 kg 620 Panel:8 1770 Unit:38 Panel:11 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Turbo fan Motor 680 40 W 2 50 2 Starting method 2 Line starting Air flow(Standard) Hi: 28 Me: 25 Lo: 23 CMM Hi: 32 Me: 28 Lo: 24 Fresh air intake Possible Air filter, Q'ty Long life filter Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8"),Gas line: 19.05(3/4") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas linse) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTWJ112,140 type Panel Part No. Standard type Attachment of ceiling material type TW-PSA-42W-E TW-PSB-48W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 945 FDC-HKXR (c) 1-way outlet ceiling recessed type (FDTS) Models FDTSJ22HKXE2B, 28HKXE2B, 36HKXE2B Model Item FDTSJ22HKXE2B(3) FDTSJ28HKXE2B(3) FDTSJ36HKXE2B(3) Nominal cooling capacity*1 W 2200 2800 3600 Nominal heating capacity*2 W 2500 3200 4000 dB(A) Hi: 39 Lo: 38 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth mm Net weight Kg Hi: 40 Me: 39 Lo: 38 Unit:194 1040 650 Panel:10 1290 770 Unit:26 Panel:6 Refrigerant equipment Heat exchanger Louver fine & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan 2 Motor 35 W Starting method 1 Line starting Air flow(Standard) Hi: 11 Lo: 8 CMM Hi: 12 Me: 11 Lo: 10 Fresh air intake Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 6.35(1/4"),Gas line: 12.7(1/2") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Model FDTSJ22,28,36 type Panel Part No. With Auto Swing TS-PSA-26W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for Europern nations which require CE marking. 946 FDC-HKXR Models FDTSJ45HKXE2B, 71HKXE2B Model FDTSJ45HKXE2B(3) Item FDTSJ71HKXE2B(3) 1 Nominal cooling capacity* W 4500 7100 Nominal heating capacity*2 W 5000 8000 Power source 1 Phase 220/240V 50Hz Noise level dB(A) Exterior dimensions Height Width Depth Net weight Hi: 43 Me: 40 Lo: 38 Unit:194 Panel:10 mm kg 1040 1290 Hi: 44 Me: 40 Lo: 38 Unit:194 Panel:10 650 770 Unit:26 Panel:6 Refrigerant equipment Heat exchanger 1300 1500 650 790 Unit:30 Panel:7 Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan 2 Motor Centrifugal fan 4 40 1 W 25 2 Starting method Line starting Air flow(Standard) CMM Hi: 14 Me: 12 Lo: 10 Hi: 18 Me: 15 Lo: 12 Fresh air intake Possible Air filter, Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 6.35(1/4") Gas line: 12.7(1/2") mm(in) Liquid line: 9.52(3/8") Gas line: 15.88(5/8") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Decorative Panel Optional parts Outdoor units to be combined FDCP2001HKXRE2, 2501HKXRE2 Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB 1 27 19 35 24 Heating*2 20 7 6 Operation Cooling* Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" Decorative Panel model (Optional) Item Panel Part No. With Auto Swing Model FDTSJ45 type TS-PSA-26W-E FDTSJ71 type TS-PSA-36W-E (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 947 FDC-HKXR (d) Cassetteria type (FDR) Models FDRJ22HKXE2, 28HKXE2 Models FDRJ22HKXE2(4) Item Air inlet panel Panel model (Option) FDRJ28HKXE2(4) Silent panel Canvas panel Silent panel Canvas panel R-PNLS-26W-E R-PNLC-26W-E R-PNLS-26W-E R-PNLC-26W-E Nominal cooling capacity*1 W 2200 2800 Nominal heating capacity*2 W 2500 3200 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight mm kg Hi: 41 Me: 39 Lo: 36 Hi: 42 Me: 40 Lo: 37 Hi: 42 Me: 40 Lo: 37 Hi: 43 Me: 41 Lo: 38 Unit:355 750 635 Unit:(299+α) 750 635 Unit:355 750 635 Unit:(299+α) 750 635 Panel:10 1040 750 Panel:10 864 585 Panel:10 1040 750 Panel:10 864 585 Unit:30 Panel:7 Unit:30 Panel:5 Unit:30 Panel:7 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Unit:30 Panel:5 Centrifugal fan 2 Motor 40 1 W 50 1 Starting method Line starting Air flow(Standard) Hi: 10 Me: 9 Lo: 8 CMM Available static pressure ( at Me) Pa(mmAq) Hi: 12 Me: 11 Lo: 10 Standard:45(4.5), Hi speed:85(8.5) Fresh air intake Side or back Air filter Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 6.35(1/4"),Gas line: 12.7(1/2") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Silent panel, Canvas panel, Canvas duct Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1)The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2)This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3)Canvas panel is used in combination with following canvas duct Canvas duct: HA01503 (4)The number "2",following the type of each model,represents"CE-marked model"especially for European Union, and for European nations which require CE marking. (5)Add the canvas duct lenght to the unit height for the canvas type. 948 FDC-HKXR Models FDRJ45HKXE2, 56HKXE2 Models FDRJ45HKXE2(4) Item Air inlet panel Panel model (Option) FDRJ56HKXE2(4) Silent panel Canvas panel Silent panel Canvas panel R-PNLS-26W-E R-PNLC-26W-E R-PNLS-26W-E R-PNLC-26W-E Nominal cooling capacity*1 W 4500 5600 Nominal heating capacity*2 W 5000 6300 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight mm kg Hi: 43 Me: 40 Lo: 37 Hi: 44 Me: 41 Lo: 38 Hi:43 Me: 40 Lo: 37 Unit:(299+α) 750 635 Unit:355 750 635 Unit:(299+α) 750 635 Unit:355 750 635 Panel:10 1040 750 Panel:10 864 585 Panel:10 1040 750 Panel:10 864 585 Unit:30 Panel:7 Unit:30 Panel:5 Unit:30 Panel:7 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan Motor Hi: 44 Me: 41 Lo: 38 W Unit:30 Panel:5 2 55 1 Starting method Line starting Air flow(Standard) Available static pressure ( at Me) CMM Hi: 14 Me: 12 Lo: 11 Pa(mmAq) Standard:50(5.0), Hi speed:85(8.5) Fresh air intake Side or back Air filter Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8") Gas line: 15.88(5/8") Liquid line: 6.35(1/4") Gas line: 12.7(1/2") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Silent panel, Canvas panel, Canvas duct Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1)The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 2 20 7 6 Operation Heating* Standards ISO-T1,JIS B8616 (2)This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3)Canvas panel is used in combination with following canvas duct Canvas duct: HA01503 (4)The number "2",following the type of each model,represents"CE-marked model"especially for European Union, and for Europearn nations which require CE marking. (5)Add the canvas duct lenght to the unit height for the canvas type. 949 FDC-HKXR Models FDRJ71HKXE2, 90HKXE2 Models FDRJ71HKXE2(4) Item Air inlet panel Panel model (Option) FDRJ90HKXE2(4) Silent panel Canvas panel Silent panel Canvas panel R-PNLS-36W-E R-PNLC-36W-E R-PNLS-36W-E R-PNLC-36W-E Nominal cooling capacity*1 W 7100 9000 Nominal heating capacity*2 W 8000 10000 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight mm kg Hi: 43 Me: 40 Lo: 37 Hi: 44 Me: 41 Lo: 38 Hi: 43 Me: 40 Lo: 37 Hi: 44 Me: 41 Lo: 38 Unit:(299+α) 950 635 Unit:355 950 635 Unit:(299+α) 950 635 Unit:355 950 635 Panel:10 1240 750 Panel:10 1064 585 Panel:10 1240 750 Panel:10 1064 585 Unit:35 Panel:8 Unit:35 Panel:6 Unit:35 Panel:8 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Unit:35 Panel:6 Centrifugal fan 2 Motor W 100 1 90 1 Starting method Line starting Air flow(Standard) Hi: 18 Me: 16 Lo: 14 CMM Available static pressure ( at Me) Pa(mmAp) Hi: 20 Me: 18 Lo: 15 Standard:45(4.5), Hi speed:80(8.0) Fresh air intake Side or back Air filter Q'ty Long life filter Shock & vibration absorber 1(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 9.52(3/8"),Gas line: 15.88(5/8") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Silent panel, Canvas panel, Canvas duct Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1)The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 2 20 7 6 Operation Heating* Standards ISO-T1,JIS B8616 (2)This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3)Canvas panel is used in combination with following canvas duct Canvas duct: HA01490 (4)The number "2",following the type of each model,represents"CE-marked model"especially for European Union, and for European nations which require CE marking. (5)Add the canvas duct lenght to the unit height for the canvas type. 950 FDC-HKXR Models FDRJ112HKXE2, 140HKXE2 Models FDRJ112HKXE2(4) Item Air inlet panel Panel model (Option) FDRJ140HKXE2(4) Silent panel Canvas panel Silent panel Canvas panel R-PNLS-46W-E R-PNLC-46W-E R-PNLS-46W-E R-PNLC-46W-E Nominal cooling capacity*1 W 11200 14000 Nominal heating capacity*2 W 12500 16000 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight dB(A) Hi: 45 Me: 42 Lo: 38 mm Unit:406 1370 635 Panel:10 1660 750 kg Unit:50 Panel:9 Hi: 46 Me: 43 Lo: 39 Hi: 46 Me: 43 Lo: 39 Unit:(350+α) 1370 635 Unit:406 1370 635 Panel:10 1484 585 Panel:10 1660 750 Unit:50 Panel:7 Unit:(350+α) 1370 635 Panel:10 1484 585 Unit:52 Panel:9 Unit:52 Panel:7 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Hi: 47 Me: 44 Lo: 40 Centrifugal fan 3 Motor W 45 1, 90 1 50 1, Starting method 100 1 Line starting Air flow(Standard) Hi: 28 Me: 25 Lo: 22 CMM Available static pressure ( at Me) Pa(mmAq) Hi: 34 Me: 31 Lo: 27 Standard:50(5.0), Hi speed:80(8.0) Fresh air intake Side or back Air filter Q'ty Long life filter Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 9.52(3/8"),Gas line: 19.05(3/4") Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories Silent panel, Canvas panel, Canvas duct Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1)The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 2 20 7 6 Operation Heating* Standards ISO-T1,JIS B8616 (2)This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3)Canvas panel is used in combination with following canvas duct Canvas duct: HA01484 (4)The number "2",following the type of each model,represents"CE-marked model"especially for European Union, and for European nations which require CE marking. (5)Add the canvas duct lenght to the unit height for the canvas type. 951 FDC-HKXR (e) Satellite ducted type (FDUM) Models FDUMJ36HKXE2, 45HKXE2 Models FDUMJ36HKXE2(3) Item FDUMJ45HKXE2(3) Nominal cooling capacity*1 W 3600 4500 Nominal heating capacity*2 W 4000 5000 dB(A) Hi: 34 Me: 32 Lo: 29 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight Hi: 35 Me: 32 Lo: 29 mm 299 kg 750 635 34 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan Motor 2 50 1 W 55 1 Starting method Line starting Air flow(Standard) Hi: 12 Me: 11 Lo: 10 CMM Available static pressure ( at Me) Pa(mmAq) Hi: 14 Me: 12 Lo: 11 Standard:50(5), Hi speed:85(8.5) Fresh air intake Side _ Air filter, Q'ty Shock & vibration absorber Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 6.35(1/4"),Gas line: 12.7(1/2") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 952 FDC-HKXR Models FDUMJ56HKXE2, 71HKXE2, 90HKXE2 Models Item FDUMJ56HKXE2(3) FDUMJ71HKXE2(3) FDUMJ90HKXE2(3) 1 Nominal cooling capacity* W 5600 7100 9000 Nominal heating capacity*2 W 6300 8000 10000 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight mm Hi: 35 Me: 32 Lo: 29 299 750 kg Hi: 35 Me: 32 Lo: 29 635 299 34 Hi: 36 Me: 33 Lo: 30 950 635 40 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan 2 Motor W 55 1 90 1 Starting method 100 1 Line starting Air flow(Standard) CMM Available static pressure ( at Me) Hi: 14 Me: 12 Lo: 11 Pa(mmAq) Hi: 18 Me: 16 Lo: 14 Hi: 20 Me: 18 Lo: 15 Standard:50(5), Hi speed:85(8.5) Fresh air intake Side _ Air filter, Q'ty Shock & vibration absorber Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8"),Gas line: 15.88(5/8") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 953 FDC-HKXR Models FDUMJ112HKXE2, 140HKXE2 Models FDUMJ112HKXE2(3) Item FDUMJ140HKXE2(3) Nominal cooling capacity*1 W 11200 14000 Nominal heating capacity*2 W 12500 16000 dB(A) Hi: 38 Me: 35 Lo: 32 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight Hi: 39 Me: 37 Lo: 34 mm 350 kg 1370 635 57 59 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan 3 Motor W 45 1, 50 1, 100 1 90 1 Starting method Line starting Air flow(Standard) Available static pressure ( at Me) CMM Hi: 28 Me: 25 Lo: 22 Hi: 34 Me: 31 Lo: 27 Pa(mmAq) Standard:60(6), Hi speed:90(9) Standard:60(6), Hi speed:85(8.5) Fresh air intake Side _ Air filter, Q'ty Shock & vibration absorber Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8"),Gas line: 19.05(3/4") mm(in) Flare piping Connecting method Connectable with VP25 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 954 FDC-HKXR (f) Ceiling suspension type (FDE) Models FDEJ36HKXE2B, 45HKXE2B Models Item FDEJ36HKXE2B(3) FDEJ45HKXE2B(3) 4500 Nominal cooling capacity*1 W 3600 Nominal heating capacity*2 W 4000 5000 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight Hi: 43 Me:40 Lo: 38 mm 184 kg 1000 650 22 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve + Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan 2 Motor 40 1 W Starting method Line starting Air flow(Standard) CMM Hi: 14 Me: 12 Lo: 10 Fresh air intake Not possible Air filter, Q'ty Polypropylene net Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 6.35(1/4"), Gas line: 12.7(1/2") Flare piping Connecting method Connectable with VP20 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 955 FDC-HKXR Models FDEJ56HKXE2B, 71HKXE2B Models FDEJ56HKXE2B(3) Item FDEJ71HKXE2B(3) 1 Nominal cooling capacity* W 5600 7100 Nominal heating capacity*2 W 6300 8000 dB(A) Hi: 43 Me:40 Lo: 38 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight mm 184 kg 1000 Hi: 44 Me:40 Lo: 38 650 184 1260 22 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve + Capillary tube Air handling equipment Fan type & Q'ty 650 27 Centrifugal fan 2 Centrifugal fan 4 W 40 1 25 2 CMM Hi: 14 Me: 12 Lo: 10 Motor Starting method Line starting Air flow(Standard) Fresh air intake Hi: 18 Me: 15 Lo: 12 Not possible Air filter, Q'ty Polypropylene net Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 9.52(3/8"), Gas line: 15.88(5/8") Flare piping Connecting method Connectable with VP20 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 956 FDC-HKXR Models FDEJ112HKXE2B, 140HKXE2B Models FDEJ112HKXE2B(3) Item FDEJ140HKXE2B(3) 1 Nominal cooling capacity* W 11200 14000 Nominal heating capacity*2 W 12500 16000 dB(A) Hi: 49 Me:46 Lo: 42 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight mm 239 kg 1260 Hi: 50 Me:47 Lo: 42 650 239 Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve +Capillary tube Air handling equipment Fan type & Q'ty 650 40 Refrigerant equipment Heat exchanger Centrifugal fan Centrifugal fan 3 W 35 1 + 55 1 CMM Hi: 28 Me: 25 Lo: 22 Motor 1470 34 4 55 2 Starting method Line starting Air flow(Standard) Fresh air intake Hi: 34 Me: 30 Lo: 26 Not possible Polypropylene net Air filter, Q'ty Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 9.52(3/8"), Gas line: 19.05(3/4") Flare piping Connecting method Connectable with VP20 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 957 FDC-HKXR (g) Wall mounted type (FDK) Models FDKJ22HKXE2, 28HKXE2, 36HKXE2, 45HKXE2 Models Item FDKJ22HKXE2(3) FDKJ28HKXE2(3) FDKJ36HKXE2(3) FDKJ45HKXE2(3) Nominal cooling capacity*1 W 2200 2800 3600 4500 Nominal heating capacity*2 W 2500 3200 4000 5000 dB(A) Hi: 42 Lo: 37 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight Hi: 42 Me:40 Lo: 37 mm 375 kg 950 Hi: 44 Me:41 Lo: 37 194 19 Refrigerant equipment Heat exchanger Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve + Capillary tube Air handling equipment Fan type & Q'ty Tangential fan 1 Motor W 30 1 35 1 Starting method Line starting Air flow(Standard) CMM Hi: 9 Lo: 8 Hi: 10 Me: 9 Lo: 8 Fresh air intake Hi: 11.5 Me: 10 Lo: 8 Not possible Air filter, Q'ty Polypropylene net Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 6.35(1/4"), Gas line: 12.7(1/2") Flare piping Connecting method Connectable with I.D. 16mm Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit Accessories — Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 958 FDC-HKXR Models FDKJ56HKXE2, 71HKXE2 Model FDKJ56HKXE2(3) FDKJ71HKXE2(3) W 5600 7100 W 6300 Item 1 Nominal cooling capacity* Nominal heating capacity*2 8000 Power source 1 Phase 220/240V 50Hz dB(A) Noise level Exterior dimensions Height Width Depth Net weight Hi: 46 Me:43 Lo: 39 mm 375 1148 kg Hi: 47 Me:44 Lo: 40 194 375 Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve + Capillary tube Air handling equipment Fan type & Q'ty Tangential fan 1 W 194 22 Refrigerant equipment Heat exchanger Motor 1436 20 Tangential fan 2 40 1 45 1 Starting method Line starting Air flow(Standard) CMM Hi: 17 Me: 15 Lo: 13 Fresh air intake Hi: 21 Me: 18 Lo: 15 Not possible Air filter, Q'ty Polypropylene net Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKX-S-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 9.52(3/8"), Gas line: 15.88(5/8") Flare piping Connecting method Connectable with I.D. 16mm Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 959 FDC-HKXR (h) Floor standing exposed type (FDFL) Models FDFLJ28HKXE2, 45HKXE2, 71HKXE2 Model Item FDFLJ28HKXE2(3) FDFLJ45HKXE2(3) FDFLJ71HKXE2(3) Nominal cooling capacity*1 W 2800 4500 7100 Nominal heating capacity*2 W 3200 5000 8000 dB(A) Hi: 41 Me:38 Lo: 36 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight mm 630 kg Hi: 43 Me:41 Lo: 40 1196 225 630 32 Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve + Capillary tube Air handling equipment Fan type & Q'ty Centrifugal fan W 2 30 1 40 1 Starting method Line starting Air flow(Standard) CMM Hi: 12 Me: 11 Lo: 10 Hi: 14 Me: 12 Lo: 10 Fresh air intake Hi: 18 Me: 15 Lo: 12 Not possible Air filter, Q'ty Polypropylene net Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKXFL-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8") Gas line: 15.88(5/8") Liquid line: 6.35(1/4") Gas line: 12.7(1/2") mm(in) Flare piping Connecting method Connectable with VP20 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 960 225 40 Refrigerant equipment Heat exchanger Motor 1481 FDC-HKXR (i) Floor standing hidden type (FDFU) Models FDFUJ28HKXE2, 45HKXE2, 56HKXE2, 71HKXE2 Model Item FDFUJ28HKXE2(3) FDFUJ45HKXE2(3) FDFUJ56HKXE2(3) FDFUJ71HKXE2(3) Nominal cooling capacity*1 W 2800 4500 5600 7100 Nominal heating capacity*2 W 3200 5000 6300 8000 dB(A) Hi: 41 Me:38 Lo: 36 Power source 1 Phase 220/240V 50Hz Noise level Exterior dimensions Height Width Depth Net weight mm Hi: 43 Me:41 Lo: 40 630 1077 kg 225 630 25 Louver fins & inner grooved tubing Refrigerant control Electronic Expansion Valve + Capillary tube Centrifugal fan Motor W 225 32 Refrigerant equipment Heat exchanger Air handling equipment Fan type & Q'ty 1362 2 30 1 40 1 Starting method Line starting Air flow(Standard) CMM Hi: 12 Me: 11 Lo: 10 Hi: 14 Me: 12 Lo: 10 Fresh air intake Hi: 18 Me: 15 Lo: 12 Not possible Air filter, Q'ty Polypropylene net Shock & vibration absorber 2(Washable) Rubber sleeve(for fan motor) Insulation (noise & heat) Polyurethane foam Operation control Operation switch Remote control switch (Optional:RCD-HKXFL-E2) Room temperature control Thermostat by electronics Internal thermostat for fan motor. Frost protection thermostat Safety equipment Installation data Refrigerant piping size Liquid line: 9.52(3/8") Gas line: 15.88(5/8") Liquid line: 6.35(1/4") Gas line: 12.7(1/2") mm(in) Flare piping Connecting method Connectable with VP20 Drain hose Necessary (both Liquid & Gas lines) Insulation for piping Mounting kit _ Accessories Optional parts FDCP2001HKXRE2, 2501HKXRE2 Outdoor units to be combined Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling*1 27 19 35 24 Heating*2 20 7 6 Operation Standards ISO-T1,JIS B8616 (2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616"UNITARY AIR-CONDITIONERS" (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. 961 FDC-HKXR (2) Outdoor unit Models FDCP2001HKXRE2, 2501HKXRE2 Models Item FDCP2001HKXRE2(3) Power source FDCP2501HKXRE2(3) 3 Phase 380/415V 50Hz Nominal cooling capacity*1 W 22400 Nominal heating capacity*2 W 25000 28000 31500 60 dB(A) Noise level Exterior dimensions Height Width Depth mm Net weight 1700 kg Refrigerant equipment compressor type & Q' ty Motor 1350 600 340 361 RS5555HAS11 RS5570HAS11 5.5 kW 7.5 Starting method Direct start Capacity control % Crankcase heater W 100 ~ 22.0 40 Louver fines & inner grooved tubing Heat exchanger Refrigerant control Expansion Valve +Capillary tube Refrigerant R407C Quantity kg 11 Refrigerant oil 2.5 (MA32) Defrost control MC controlled De-Icer Air handling equipment Fan type & Q'ty Centrifugal fan 2 Motor W 100 2 Starting method Direct start Air flow(Standard) CMM 175 Shock & vibration absorber Rubber mount (for compressor) Compressor overheat protection, overeurrent protection, power transformer overheating protection, abnormal high pressure protection Safety equipment Installation data Refrigerant piping size mm(in) Liquid line: 12.7(1/2") Intake line: 25.4(1") Discharge line: 19.05(3/4") Connecting method Liquid line: 12.7(1/2") Intake line: 28.58(11/8") Discharge line: 19.05(3/4") Brazing Drain Hole for drain( 20 Insulation for piping 6pcs) Necessary (both Liquid &Gas lines) Discharge gas side connection piping (for pervice valve and back direction connections), intake gas side connection piping (for operation valve and back direction connections) Accessories Indoor units to be combined FDTJ28, 36, 45, 56, 71, 90, 112, 140HKXE2 FDTWJ28, 45, 56, 71, 90, 112, 140HKXE2B FDTSJ22, 28, 36, 45, 71HKXE2B FDRJ22, 28, 45, 56, 71, 90, 112, 140HKXE2 FDUMJ36, 45, 56, 71, 90, 112, 140HKXE2 FDEJ36, 45, 56, 71, 112, 140HKXE2B FDKJ22, 28, 36, 45, 56, 71HKXE2 FDFLJ28, 45, 71HKXE2 FDFUJ28, 45, 56, 71HKXE2 Notes (1) The cooling and heating capabilities imply the values when the indoor unit of rated capacity is connected under the condition specified in JIS-B8616. (2) The refrigerant quantity in the connecting pipe is not included Charge it additionally at the site. (3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which require CE marking. (4) When an individual flow divide controller is used a pipe part set is required. Flow divide controller part No. list Type Individual flow divide controller Part No. FDCP2001,2501 HPFD01R-E Type For 3 pipes (for horizontal division) For 3 pipes (for vertical division) 962 Part No. FDCP2001,2501 DIS-IKXR3-E DIS-VIKXR3-E FDC-HKXR (3) Operation chart Since the Multi KXR series air conditioner units are free multitype to which the indoor units of different capacity and different model can be combined, the operation characteristics of all combinations are very complicated, therefore only the individual operation characteristics of indoor and outdoor units are shown. For the combined operation characteristics, calculate them with the method shown in the next page. (a) Operating characteristic of outdoor unit Models Item Cooling input kW Heating input Cooling running current A Heating running current Inrush current (MAX.) (380 V/415 V) FDCP2001HKXRE2 FDCP2501HKXRE2 10.2/10.2 12.4/12.4 8.4/8.4 9.2/9.2 15.9/14.6 21.8/20.0 13.3/12.2 15.6/14.3 5 5 97/97 86/86 96/96 90/90 A Cooling power factor % Heating power factor Note (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 “UNITARY AIR-CONDITIONERS” (b) Operating characteristic of indoor unit FDT Series (220 V/240 V) Models FDT Series 71 90 112 140 Power input (kW) 28 0.09/0.10 0.10/0.12 0.10/0.12 0.11/0.13 0.17/0.20 0.21/0.24 Running current (A) 0.40/0.44 0.45/0.49 0.47/0.50 0.50/0.55 0.75/0.81 0.93/1.02 Item 36 45 56 FDTW Series (220 V/240 V) Models FDTW Series 28 Item 45 56 71 90 112 140 Power input (kW) 0.09/0.10 0.10/0.11 0.12/0.13 0.18/0.20 0.20/0.24 Running current (A) 0.43/0.44 0.48/0.50 0.57/0.59 0.86/0.89 0.90/0.98 FDTS Series (220 V/240 V) Models Item FDTS Series 45 71 Power input (kW) 0.07/0.08 0.10/0.11 0.12/0.15 Running current (A) 0.33/0.36 0.43/0.46 0.58/0.63 22 28 36 FDR, FDUM Series (220 V/240 V) Models Item FDR, FDUM Series 22 28, 36 71 90 112 140 Power input (kW) 0.09/0.11 0.11/0.13 45 0.14/0.16 56 0.15/0.17 0.16/0.19 0.24/0.28 0.28/0.32 Running current (A) 0.41/0.46 0.51/0.56 0.63/0.67 0.68/0.71 0.73/0.79 1.07/1.17 1.28/1.32 FDE Series (220 V/240 V) Models Item FDE Series 36 45 56 71 112 140 Power input (kW) 0.10/0.11 0.12/0.15 0.20/0.24 0.24/0.29 Running current (A) 0.43/0.46 0.58/0.63 0.90/0.98 1.10/1.20 Notes (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 “UNITARY AIR-CONDITIONERS” (2) The values shown in the above table are common to both cooling and heating operations. 963 FDC-HKXR FDK, FDFL, FDFU Series (220 V/240 V) Models Item FDK Series 22 28 36 FDFL, FDFU Series 45 56 71 28 45,56 71 Power input (kW) 0.05/0.06 0.06/0.07 0.08/0.09 0.09/0.11 0.09/0.10 0.09/0.10 0.09/0.10 Running current (A) 0.26/0.28 0.31/0.33 0.36/0.39 0.41/0.48 0.41/0.42 0.40/0.41 0.40/0.41 Notes (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 “UNITARY AIR-CONDITIONERS” (2) The values shown in the above table are common to both cooling and heating operations. (c) Calculation of total operation characteristics Since the operation characteristics of series Multi-KXR depend on combination of indoor unit, calculate the total operation characteristics of the system by using the formulas below according to specifications of each indoor unit or outdoor unit. 1) Total power input Total power input (kW) = Power input of outdoor unit + ∑ (Power input of indoor unit) 2) Total running current Total running current (A) = Running current of outdoor unit + [∑ (Running current) × 2/3] 3) Total power factor — Total power factor (%) = [Total power input (W) / √ 3 × Total running current (A) × Power source] × 100 Total operation characteristics = Operation characteristic value of outdoor unit + Operation characteristic value of indoor unit [Example] (Conditions) Operation Voltage ········Indoor unit: 220 V, 50 Hz Outdoor unit: 380 V, 50 Hz Operation mode ··········· Cooling and Heating Unit·······························Outdoor unit: FDCP2501HKXRE2 × 1 unit Indoor unit: FDTJ71HKXE2 × 2 units FDTJ45HKXE2 × 2 units Operation characteristics of each unit (Cooling/Heating) Models FDCP2501HKXRE2 FDTJ71HKXE2 FDTJ45HKXE2 Power input (kW) 12.4/9.2 0.10/0.10 0.10/0.10 Running current (A) 21.8/15.6 0.47/0.47 0.45/0.45 Item 1 Total power input (kW) (Cooling) 12.4 + (0.10 × 4) = 12.8 (kW) (Heating) 0.2 + (0.10 × 4) = 9.6 (kW) 2 Total running current (A) . (Cooling) 21.8 + (0.47 × 2 + 0.45 × 2) × 2 =. 23.0 (A) 3 . (Heating) 15.6 + (0.47 × 2 + 0.45 × 2) × 2 =. 16.8 (A) 3 3 Total power factor (%) 964 (Cooling) 12.8 × 1000 — √ 3 × 23.0 × 380 . × 100 =. 85 % (Heating) 9.6 × 1000 — √ 3 × 16.8 × 380 . × 100 =. 87% FDC-HKXR • Correction factor of compressor power input Model FDCP2001HKXRE2 Model FDCP2501HKXRE2 1.0 Power consumption correction coefficietnt Power consumption correction coefficietnt 1.0 0.8 0.6 0.4 0.2 Total capacity of indoor units operating simulataneously 45 105 (Below, the coefficients are the same.) 164 224 0.8 0.6 0.4 0.2 Total capacity of indoor units operating simulataneously (Below, the coefficients are the same.) 45 90 105 (Below, the coefficients are the same.) 164 224 280 (Below, the coefficients are the same.) 965 FDC-HKXR 20.2.2 Range of usage & limitations System FDCP2001HKXRE2 FDCP2501HKXRE2 Item Indoor intake air temperature (Upper, lower limits) Refer to the selection chart. Outdoor air temperature (Upper, lower limits) Indoor units that can be used in combination 1 to 8 units Number of connected units Total capacity 11000 to 29200w Single direction piping lenght 13200 to 37100w Indoor unit MAX 100m Piping length after first division MAX 30m Difference in height between indoor and outdoor units When above outdoor unit MAX 50m When below outdoor unit MAX 10m MAX 15m Difference in height between indoor units Indoor unit atmosphere (behind ceiling) temperrature and humidity Compressor stop/start frequency Dew point temperature 28 1 cycle time 6 min or more(from stop to stop or from start to start) Stop time Power source voltage or less, relative humidity 80% or less 3 min or more Voltage fluctuation _ 10% of rated voltage Within + Voltage drop during start _ 15% of rated voltage Within + Interval unbalance Within _+ 3% of rated voltage Allowable length of refrigerant piping, Height difference between indoor and outdoor unit Individual flow divide controller Outdoor unit (Max 70m ) Indoor unit Max 30m First branch Max 15m 50m (Outdoor unit is lower : 10m) (Highest indoor unit) Individual flow divaide controller Max 30m (Lowest indoor unit) Between the outdoor unit and first branch (main piping): Max 70m (actual length) Between the first branch and each indoor unit : Max 30m (each indoor unit) (actual length) Note (1) The indoor unit and individual flow divide controller positions should be within the range of the reach of the connections of the wires that come with the individual flow divide contoroller 966 FDC-HKXR 20.2.3 Exterior dimensions (1) Indoor unit (a) Ceiling recessed type (FDT) Models FDTJ28HKXE2, 36HKXE2, 45HKXE2, 56HKXE2, 71HKXE2, 90HKXE2 Unit : mm Decorative Panel Holes for suspension bolts (M10 to M8 ×4pcs.) 860~890 (Ceiling hole size) Fresh air opening for ducting 780 (Suspension bolts pitch ) 950 630 C 400 B→ Liquid piping 28, 36, 45 type: φ6.35(1/4") 56, 71, 90 type: φ9.52(3/8") Gas piping 28, 36, 45 type: φ12.7(1/2") 56, 71, 90 type: φ15.88(5/8") 267 Drain hose (Accessories) (Local setting) 332 420 637 D 422 675 (Suspension bolts pitch) Exhaust air opening for ducting 310 Air outlet Air inlet grille VIEW A 840 Suspension bolts Hole for wiring Control box 260 30 ↑ A 187 137 95 VIEW B Holes for tapping screws 6-φ4.0 Holes for tapping screws 4-φ4.0 55 140 25 Space for installation and service VIEW C 1000 42 80 140 112 100 113 140 160 33 60 Obstacle or more 210 45 or more Lug for suspension bolts 700 or less (Max. Drain up) 295~325 Drain (Connectable with VP25) 1000 or more VIEW D 967 FDC-HKXR Models FDTJ112HKXE2, 140HKXE2 Unit : mm Decorative Panel Holes for suspension bolts (M10 to M8 ×4pcs.) 860~890 (Ceiling hole size) Fresh air opening for ducting 780 (Suspension bolts pitch ) 950 630 C 400 B→ Liquid piping φ9.52(3/8") 267 Drain hose (Accessories) (Local setting) 332 420 637 D 422 675 (Suspension bolts pitch) Exhaust air opening for ducting Air outlet 310 Air inlet grille VIEW A Gas piping φ19.05(3/4") 840 Drain (Connectable with VP25) Lug for suspension bolts Control box 55 700 or less (Max. Drain up) VIEW B Space for installation and service 140 25 VIEW C 1000 Obstacle or more 42 VIEW D 140 112 100 113 140 160 33 60 80 968 320 A Holes for tapping screws 6-φ4.0 Holes for tapping screws 4-φ4.0 187 Hole for wiring 30 → 45 or more 95 137 270 295~325 1000 or more FDC-HKXR (b) 2-way outlet ceiling recessed type (FDTW) Models FDTWJ28HKXE2B, 45HKXE2B, 56HKXE2B Unit : mm Drain hose (Accessories) (Local setting) 278 64 47 Hole Suspension fitting Fresh air opening for ducting (knock out) 97 50 Holes of tapping screws 5 - φ4 264 91 Center of panel 640 70 Suspension bolts (M10 × 4 pcs.) (Ceiling hole size) 446 Control box (Suspension bolts pitch) 97 417 468 310 98 90 95 885 (Suspension bolts pitch) 40 120 1015 (Ceiling hole size) VIEW A 460 178 200 130 295~ 325 200 750 or less 280 Hole Hole 364 310 230 169 8 Hole Hole 74 20 124 Hole for wiring 20 Drain(VP20) (Natural drainage) Exhaust air opening for ducting (knock out) Holes for tapping screws 8 – φ4 Decorative Panel 1055 Air outlet Air inlet 100 or more 1000or more 360 680 160 Space for installation and service 160 ↑ A 140 100 130 Liquid piping 28, 45 tipe : φ6.35(1/4") 56 type : φ9.52(3/8") 148 240 20 Gas piping 28, 45type: φ12.7(1/2") 56 type: φ15.88(5/8") Drain(VP25) (condensate pump drain) 207 240 10 620 405 (Max. Drain up) 178 10 20 56 227 817 56 100 or more 1500 or more 1500 or more Obstruction 45 965 45 969 FDC-HKXR Models FDTWJ71HKXE2B, 90HKXE2B Unit : mm 1054 382 240 240 200 200 295~ 325 Liquid piping φ9.52(3/8") ↑ 240 Holes for tapping screws 8 – φ4 128 Drain (VP25) (condensate pump drain) Hole for wiring 20 Drain (VP20) (Natural drainage) Exhaust air opening for ducting (knock out) Decorative Panel 64 Gas piping φ15.88(5/8") 230 8 750 or less Hole 78 20 310 A 20 10 364 330 Hole 88 640 50 95 620 410 100 140 10 148 460 VIEW A 219 212 Hole 20 66 (Max. Drain up) 66 264 Suspension fitting Fresh air opening for ducting (knock out) 97 50 Holes of taping screws 5 – φ4 277 Center of panel Suspension bolts (M10 × 4 pcs.) (Ceiling hole size) 70 446 Control box 310 278 97 540 (Suspension bolts pitch) 590 90 95 1130 (Suspension bolts pitch) 40 Drain hose (Accesories) (Local setting) 120 1260 (Ceiling hole size) Space for installation and service Air outlet Air inlet 160 100 or more 1000or more 1300 100 or more 160 360 680 Obstruction 45 970 1210 45 1500 or more 1500 or more FDC-HKXR Models FDTWJ112HKXE2B, 140HKXE2B 310 50 64 110 103 Hole 130 70 50 Suspension fitting Fresh air opening for ducting (knock out) 97 Center of panel 640 (Ceiling hole size) Control box Holes for tapping screws 5-ø4 Suspension bolts (M10 × 4 pcs.) 97 775 264 (Local setting) 446 (Suspension bolts pitch) 825 90 95 1730 (Ceiling hole size) 1600 (Suspension bolts pitch) 40 278 Drain hose (Accessories) VIEW A 200 345 255 A→ Hole 20 78 Holes for tapping screws 8-ø4 128 Exhaust air opening for ducting (knock out) 20 10 20 Gas piping ø15.88(5/8") Drain(VP25) (condensate pump drain) 410 364 310 Liquid piping ø9.52(3/8") 230 Drain(VP20) (Natural drainage) 8 140 Hole 620 292 240 200 100 240 295~ 325 10 234 672 Max. drain up 240 750 or less 612 20 66 163 1524 66 Hole for wiring 1770 Air outlet Air inlet 160 100 or more 1000 or more 680 360 160 Space for installation and service 100 or more 1500 or more 1500 or more Obstruction 45 1680 45 Decorative Panel 971 FDC-HKXR (c) 1-Way outlet ceiling recessed type (FDTS) Models FDTSJ22HKXE2B, 28HKXE2B, 36HKXE2B, 45HKXE2B 70 35 50 25 383 25 168 Panel center 200 45 250 150 60 285 315 180 435 90 Drain hose (Accessories) (Local setting) VIEW A Suspension bolts (M10×4 pcs.) 295~325 235 940 115 194 ←C 10 165 100 600 or less Max. Drain up 70 710 (Ceiling hole size) B→ 600 (Suspension bolts pitch) 40 555 Holes for tapping screws (φ4-6pcs.) 290 70 60 1230 (Ceiling hole size) 990 (Suspension bolts pitch) Unit : mm 140 Fresh air opening for ducting (Knock out) Fresh air opening for ducting (knock out) 100 50 A ↓ Fresh air opening for ducting (Knock out) 30 30 205 85 Air outlet 920 245 Fresh air opening for ducting (Knock out) 85 125 40 90 290 140 60 50 770 100 35 Air inlet grille 70 45 45 1200 45 70 140 1290 Holes for tapping screws (φ4.0 − 6 pcs.) VIEW B Decorative Panel 30 45 15 650 30 Space for installation and service 415 275 100 or more 215 1000 or more 370 Liquid piping φ6.35(1/4") 100 or more 155 105 110 Obstacle Gas piping φ12.7(1/2") Drain (VP25) (Condensate pump drain) Hole for wiring (φ35) VIEW C 972 100 or more FDC-HKXR Model FDTSJ71HKXE2B Unit : mm 1440 (Ceiling hole size) 1250 (Suspension bolts pitch) 675 70 200 60 Drain hose(Accessories) (Local setting) 295~325 1200 200 165 170 30 10 194 100 600 or less Max. Drain up Suspension bolts (M10×4pcs.) 150 VIEW A 90 100 45 250 140 35 50 25 168 Panel center ←C 30 70 Fresh air opening for ducting (Knock out) Air outlet 1180 210 35 60 100 Air inlet grille 140 50 40 90 85 110 770 70 290 45 70 140 Holes for tapping screws (φ4-6pcs.) VIEW B 45 1410 45 1500 Decorative Panel 30 45 15 30 650 Space for installation and service 415 275 100 or more 110 215 Gas piping φ15.88(5/8") 1000 or more 370 Liquid piping φ9.52(3/8") 155 105 710 (Ceiling hole size) 145 575 Fresh air opening for ducting (Knock out) Holes for tapping screws 290 (φ4-6pcs.) 383 70 600 (Suspension bolts pitch) 40 285 315 25 ↑ B Fresh air opening for ducting (knock out) 70 Fresh air opening for ducting 45 (knock out) 100 50 ← A 100 or more 100 or more Obstacle Drain (VP25) (Condensate pump drain) Hole for wiring (φ35) VIEW C 973 FDC-HKXR (d) Cassetteria type (FDR) Model FDRJ22HKXE2 Silent Panel (Model: R-PNLS-26W-E) Unit : mm 980 (Ceiling hole size) 786 (Suspension bolts pitch) 433 353 71 45 Panel center 70 465 405 ↑ 213 MIN95 40 MIN156 MIN81 650 or less MIN320 480 A Drain(VP25) (Natural drainage) 460 Holes for tapping screws 4-φ4.0 150 1040 45 φ170 φ170 950 Air inlet 45 75 φ149 90 Fresh air opening for ducting (Knock out) Obstacle 974 50 or more Air inlet VIEW A 75 100 or more 45 1000 or more Space for installation and service 750 510 Exhaust air opening for ducting (Knock out) VIEW B 100 or more Hole for wiring (φ35) 250 45 205 635 510 355~369 00 φ2 MIN225 80 MIN206 295~325 405 B→ VIEW C Liquid piping φ6.35(1/4") Max. Drain up Gas piping φ12.7(1/2") 345 405 Drain (Connectable with VP25) Supply air duct 750 150 59 690(Ceiling hole size) 45 545(Suspension bolts pitch) 275 69 Control box Suspension bolts (M10×4pcs.) Fresh air opening for ducting (Knock out) 284 C ↓ 270 Drain hose (Accessories) (Local setting) 137 75 57 FDC-HKXR Model FDRJ22HKXE2 Canvas Panel (Model: R-PNLC -26W-E) 804 (Ceiling hole size) 786 (Suspension bolts pitch) 353 433 9 45 Fresh air opening for ducting (Knock out) 284 69 150 193 69 Drain (Connectable with VP25) Liquid piping φ6.35(1/4") Gas piping φ12.7(1/2") Control box Panel center 352 525 (Ceiling hole size) 90 ↓ 45 545 (Suspension bolt pitch) 70 C Drain hose (Accessories) (Load setting) 9 Unit : mm 405 59 VIEW C 71 Supply air duct Max. Drain up 465 149 199 40 405 260 ↓ Drain (VP20) (Natural drainage) Canvas duct (Optional parts) 480 274 35 130 B 510 299 405 345 635 150~300 295~325 750 600 or less Suspension bolts (M10×4pcs.) 80 Hole for wiring (φ35) ↑ A 250 460 213 150 Holes for tapping screws 864 φ170 φ170 Fresh air opening for ducting (Knock out) Air inlet 45 75 774 45 45 205 90 345 Exhaust air opening for ducting (Knock out) 585 φ149 75 45 VIEW B Air inlet 100 or more 1000 or more Space for installation and service 100 or more 50 VIEW A or more Obstacle 975 FDC-HKXR Models FDRJ28HKXE2, 45HKXE2, 56HKXE2 Silent Panel (Model: R-PNLS-26W-E) Unit : mm 980 (Ceiling hole size) 786 (Suspension bols pitch) 137 Fresh air opening for ducting (Knock out) (Local setting) 353 284 45 panel center 71 Supply air duct 150 690 (Ceiling hole size) 545 (Suspension bolt pitch) 45 59 405 75 275 270 Control box 70 69 C↓ VIEW C Drain (Connectable with VP25) Gas piping 28, 45 type: φ12.7 (1/2") 56 type: φ15.88 (5/8") Liquid piping 28, 45 type: φ6.35 (1/4") 56 type: φ9.52 (3/8") 635 Drain (VP20) (Natural drainage) 205 213 1040 45 45 950 Air inlet 45 150 Hole for wiring (φ35) 250 460 Holes for tapping screws φ149 40 MIN81 ↑A MIN95 0 φ20 405 MIN156 MIN320 MIN225 B→ 465 MIN206 245 320 480 355~369 185 510 650 or less 295~325 750 Suspension bolts (M10 × 4pcs.) Max. Drain up 80 φ170 75 433 φ170 90 Fresh air opening for ducting (Knock out) 510 Exhaust air opening for ducting (Knock out) more 1000 100 or or more Obstacle 976 100 or 50 or more more Air inlet VIEW A 75 Space for installation and service 45 VIEW B 750 57 Drain hose (Accessories) FDC-HKXR Models FDRJ28HKXE2, 45HKXE2, 56HKXE2 Canvas Panel (Model: R-PNLC-26W-E) Unit : mm Drain hose (Accessories) 804 (Ceiling hole size) 9 786 (Suspension bolts pitch) 353 284 Fresh air opening for ducting (Knock out) 45 C↓ Control box 150 193 69 Drain (Connectable with VP25) Panel center Liquid piping 28, 45 type: φ6.35 (1/4") 56 type: φ9.52 (3/8") Gas piping 28, 45 type: φ12.7 (1/2") 56 type: φ15.88 (5/8") 352 525 (Ceiling hole size) 90 (Local setting) 9 45 545 (Suspension bole pitch) 70 433 59 Supply air duct 405 VIEW C 71 149 40 405 260 35 B→ 465 199 245 130 320 480 274 185 635 510 299 295~325 750 600 or less Suspension bolts (M10 × 4pcs.) Max. Drain up 80 00 φ2 ↑ A 205 Hole for wiring (φ35) 150~ 300 Canvas duct (Optional parts) Drain (VP20) (Natural drainage) 250 460 213 φ149 864 φ170 Fresh air opening for ducting (Knock out) 75 Air inlet φ170 45 75 774 45 45 45 150 Holes for tapping screws 4-φ4.0 345 Exhaust air opening for ducting (Knock out) 585 90 VIEW B 1000 100 or more or more Space for installation and service 100 or more 50 or Air inlet VIEW A more Obstacle 977 FDC-HKXR Models FDRJ71HKXE2, 90HKXE2 Silent Panel (Model: R-PNLS-36W-E) Unit : mm 1180 (Ceiling hole size) 986 (Suspension bolts pitch) 533 137 453 Drain hose (Accessories) (Local setting) Fresh air opening for ducting (Knock out) 45 Panel center 71 465 Drain (VP20) (Natural drainage) ↑A MIN95 40 405 MIN156 MIN320 Hole for wiring (φ35) 250 460 213 205 1240 150 φ149 Holes for tapping screws (4-φ4.0) 1150 45 φ170 45 Air inlet φ170 Fresh air opening for ducting (Knock out) 45 90 510 Exhaust air opening for ducting (Knock out) VIEW B or more 1000 or 100 more 100 or more 50 or more Obstacle VIEW A 978 75 Air inlet 45 Space for installation and service 750 MIN225 0 480 MIN81 φ20 635 510 355~369 215 B→ 80 MIN206 285 650 or less 285 165 Liquid piping φ9.52(3/8") 295~325 950 VIEW C Drain (Connectable with VP25) Gas piping φ15.88(5/8") Suspension bolts (M10×4pcs.) 500 Max. Drain up Supply air duct 150 45 545 (Suspension bolts pitch) 59 75 275 270 Control box 690 (Ceiling hole size) 69 C↓ 70 284 75 57 FDC-HKXR Models FDRJ71HKXE2, 90HKXE2 Canvas Panel (Model: R-PNLC-36W-E) Unit : mm Drain hose (Accessories) (Local setting) 1004 (Ceilinghole hole size) 986 (Suspension bolts pitch) 453 69 Drain (Connectable with VP25) Control box Liquid piping φ9.52(3/8") 59 71 Supply air duct 950 510 480 465 405 149 260 35 B→ 40 215 199 285 635 80 274 285 295~325 130 165 VIEW C 299 Suspension bolts (M10 × 4pcs.) 500 Gas piping φ15.88(5/8") Max. Drain up 352 Panel center 150 45 Fresh air opening for ducting (Knock out) 284 C↑ 193 45 545 (Suspension bolts pitch) 90 525 (Ceiling hole size) 70 533 9 600 or less 9 Drain (VP20) (Natural drainage) Canvas duct (Optional Parts) 150~300 0 φ20 Hole for wiring (φ35) ↑A 250 460 45 974 Air inlet 45 φ170 90 VIEW B Air inlet 75 Exhaust air opening for ducting (Knock out) 45 Fresh air opening for ducting (Knock out) 345 φ170 585 150 Holes of tapping screws (4-φ4) 75 φ149 1064 213 45 205 VIEW A 1000 100 or more or more Space for installation and service 100 or more 50 or more Obstacle 979 FDC-HKXR Models FDRJ112HKXE2, 140HKXE2 Silent Panel (Model: R-PNLS-46W-E) Unit : mm 1600 (Ceiling hole size) 1406 (Suspension bolts pitch) 663 270 58 45 Panerl center Supply air duct 175 320 320 70 Liquid piping φ19.05(3/4") 295~325 320 VIEW C 80 (Max. Drain up) 1370 495 Drain (Connectable with VP25) 76 Gas piping φ19.05(3/4") Suspension bolts (M10 ×4pcs.) 235 635 510 480 465 405 40 φ20 MIN 96 MIN156 MIN206 Drain (VP20) (Natural drainage) MIN81 ↑A 406~420 B→ 650 or less MIN320 0 MIN276 Fresh air opening for ducting (Knock out) 150 Control box 690 (Ceiling hole size) 69 45 287 75 275 C ↑ 545 (Suspension bolts pitch) 743 57 Drain hose (Accessories) (Local setting) 137 Hole for wiring (I.D.φ35) 155 460 1660 45 75 Air inlet 45 1570 45 45 Holes of tapping screws 4-φ4 150 φ149 213 75 205 φ170 90 Exhaust air opening for dacting (Knock out) VIEW B 1000 or more Space for installation and service 100 or more 100 or more Obstacle 980 510 750 φ170 Fresh air opening for ducting (Knock out) Air inlet VIEW A 50 or more FDC-HKXR Models FDRJ112HKXE2, 140HKXE2 Canvas Panel (Model: R-PNLC-46W-E) Unit : mm 1424 (Ceiling hole size) 1406 (Suspension bolts pitch) 743 663 150 Drain (Connecteble with VP25) 495 Liquid piping φ9.52(3/8") 59 1370 465 405 86 0 200 295~325 250 235 510 325 320 635 480 350 320 600 or less 320 130 175 80 Max. Drain up 71 Supply air duct VIEW C Gas piping φ19.05(3/4") 310 352 Panel center 40 70 45 69 Control box Suspension bolts (M10 × 4pcs.) Fresh air opening for ducting (Knock out) 284 C↑ 193 Drain hose (Accessories) (Local setting) 9 45 90 545 (Suspension bolts pitch) 525 (Ceiling hole size) 9 φ20 Hole for wiring (φ35) 150~300 Canvas duct (Optional parts) ↑A 213 150 Holes of tapping screws (4-φ4) φ170 φ170 Fresh air opening for ducting (Knock out) 460 1484 1394 45 45 Air inlet 45 205 φ149 155 Drain (VP20) (Natural drainage) 75 B→ 345 585 90 Exhaust air opening for ducting (Knock out) 75 Air inlet 45 VIEW B Space for installation and service 1000 100 or more or more VIEW A 100 or more 50 or more Obstacle 981 FDC-HKXR (e) Satellite ducted type (FDUM) Models FDUMJ36HKXE2, 45HKXE2, 56HKXE2 Unit : mm 786 (Suspension bolts pitch) 750 18 80 B 205 Hole of tapping screws (4-φ4) Drain hose (Accessories) (Local setting) Drain (Connectable with VP25) 284 A→ 213 φ149 Control box φ170 Liquid piping 36, 45 type: φ6.35(1/4") 56 type: φ9.52(3/8") 118 472 (Suspension bolts pitch) 45 ↑ 18 59 Fresh air opening for ducting (Knock out) Gas piping 36, 45 type: φ12.7(1/2") 56 type: φ15.88(5/8") 71 Supply air duct φ170 90 Exhaust air opening for ducting (Knock out) 295~325 750 185 Max.Drain up VIEW A 320 245 Suspension bolts (M10×4pcs.) 80 30 635 510 480 465 0 40 149 199 274 299 600 or less 35 130 405 φ20 460 Drain (VP20) (Natural drainage) 660 45 50 200 200 Hole for wiring 45 200 50 170 620 Holes for tapping screws (12-φ4) VIEW B 982 Return air duct 1100 100 35 59 630 200 35 Space for installation and service Inspection space FDC-HKXR Models FDUMJ71HKXE2, 90HKXE2 Unit : mm 986 (Suspension bolts pitch) 950 18 472 (Suspension bolts pitch) 45 ↑ 18 80 B 205 284 118 A→ 59 71 213 Holes of tapping screws 4-φ4 φ149 Control box Drain hose (Accessories) (Local setting) Drain (Connectable with VP25) φ170 Liquid piping φ9.52(3/8") Fresh air opening Gas piping for ducting φ15.88(5/8") (Knock out) φ170 90 Exhaust air opening for ducting (Knock out) Supply air duct VIEW A 295~325 35 635 510 480 465 405 40 30 149 Suspension bolts (M10×4pcs.) 130 80 199 215 299 274 285 Max.Drain up 285 600 or less 950 165 0 φ20 460 Drain (VP20) (Natural drainage) 860 45 4×200=800 45 50 Space for installation and service Inspection space Holes for tapping screws Return air duct 100 1300 35 620 830 200 170 59 35 50 Hole for wiring VIEW B 983 FDC-HKXR Models FDUMJ112HKXE2, 140HKXE2 Unit : mm 1406 (Suspension bolts pitch) 1370 ↑ 18 205 80 B Holes of tapping screws (4-φ4) 213 φ149 Control box 284 A→ Drain hose (Accessories) (Local setting) Drain (Connectable with VP25) Liquid piping φ9.52(3/8") 58 76 Supply air duct 320 320 295~325 235 φ170 Fresh air opening for ducting (Knock out) Exhaust air opening for ducting (Knock out) 635 80 30 510 480 465 405 200 250 325 0 350 φ20 600 or less 86 130 40 Suspension bolts (M10×4pcs.) 90 VIEW A Max.Drain up 320 φ170 Gas piping φ19.05(3/4") 1370 175 150 472 118 (Suspension bolts pitch) 45 18 460 Drain (VP20) (Natural drainage) 1280 45 6×200=1200 60 Space for installation and service 1250 Return air duct VIEW B 984 620 1720 210 35 Holes for tapping screws (18-φ4) 100 240 70 35 45 60 Holes for wiring Inspection space FDC-HKXR (f) Ceiling suspension type (FDE) Models FDEJ36HKXE2B, 45HKXE2B, 56HKXEB2 Unit : mm 984 (Suspension bolts pitch) 15 15 Holes for suspension bolts (M8 to M10 × 4 pcs. Not included) The brackets face out When the unit is half recesed a bove the ceiling 195 275 135 46 94 191 150 7 50 184 50 The brackets face interior When the unit is suspended beneath the ceiling Liquid piping Gas piping 605 45 900 (Suspension bolts pitch) 940 30 650 30 185 1000 Air outlet Drain hole connection (1) 225 248 10 290 Drain hole connection 46 Note (1) The slope of drain piping inside the unit is Liquid piping able to take incline of 10 mm 36, 45 type: φ6.35 (1/4") 56 type: φ9.52 (3/8") Drain piping connection Air inlet grille Space for installation and service 30 55 35 Gas piping 36, 45 type: φ12.7(1/2") 56 type: φ15.88(5/8") 100 or more 300 30 or more 20 150 or more 5 or more Obstacles Model FDEJ71HKXE2B Unit : mm 1244 (Suspension bolts pitch) 15 15 The brackets face out When the unit is half recesed a bove the ceiling Holes for suspension bolts (M8 to M10 × 4 pcs. Not included) Liquid piping 605 135 Gas piping 275 45 195 1160 (Suspension bolts pitch) 50 46 94 184 150 The brackets face interior When the unit is suspended beneath the ceiling 191 7 50 650 30 1200 30 185 1260 Drain hole connection (1) 225 Air outlet Air inlet grille 248 290 35 55 30 Gas piping φ15.88(5/8") 100 or more 300 20 30 Drain piping connection Space for installation and service or more Drain hole connection 10 Liquid piping φ9.52 (3/8") 46 Note (1) The slope of drain piping inside the unit is able to take incline of 10 mm 150 or more 5 or more Obstacles 985 FDC-HKXR Model FDEJ112HKXE2B Unit : mm 1244 (Suspension bolts pitch) 15 15 Holes for suspension bolts (M8 to M10 × 4pcs. Not included) The brackets face out When the unit is half recesed a bove the ceiling 66 50 1200 30 Liguid piping 584 275 174 Gas piping 135 94 46 30 246 150 The brackets face interior When the unit is suspended beneath the ceiling 239 7 50 1160 (Suspension bolt pitch) 650 1260 Drain hole connection (1) 185 225 Air outlet 266 290 Drain hole connection 10 Liquid piping φ9.52 (3/8") 46 Note (1) The slope of drain hose inside the unit is able to take incline of 10 mm Air inlet grille Drain piping connection (VP20) Space for installation and service 35 55 Gas piping φ19.05 (3/4") 30 100 or more 300 30 or more 20 150 or more 5 or more Obstacles Model FDEJ140HKXE2B Unit : mm 1454 (Suspension bolts pitch) 15 15 Holes for suspension bolts (M8 to M10 × 4pcs. Not included) 66 1410 1470 30 275 Liquid piping 135 Gas piping 94 246 150 The brackets face interior When the unit is suspended beneath the ceiling 584 174 7 50 239 1370 (Suspension bolts pitch) 50 650 30 46 The brackets face out When the unit is half recesed a bove the ceiling Drain hole connection (1) 185 225 Air outlet 266 Air inlet grille 290 30 Gas piping φ19.05 (3/4") 100 or more 300 55 150 or more Obstacles 986 Drain hose connection (VP20) Space for installation and service 20 35 or more Drain hole connection 30 10 Liquid piping φ9.52 (3/8") 46 Note (1) The slope of drain piping inside the unit is able to take incline of 10 mm 5 or more FDC-HKXR (g) Wall mounted type (FDK) Models FDKJ22HKXE2, 28HKXE2, 36HKXE2, 45HKXE2 Unit : mm 950 23 387 387 130 23 4 194 7.7 59 65 710 155 820 155 77.5 25 25 20 20 25 20 20 77.5 65 155 Space for installation and service 200 Mounting plate φ8 × 48 pcs. (Holes on mounting plate) 150 200 or more or more Available space for rear connection 45 Hole on wall for rear connection 55 105 φ70 58 90 165 10 38 50 165 Detail of mounting plate Outlet for piping (On both side) or more 65 8 10 64 375 280 ←A Outlet for electric wiring Piping cover Gas piping φ 12.7 (1/2") Liquid piping 608 φ 6.35 (1/4") 60 55 Drain hose 0.7 m 712 VIEW A (Rear side) Model FDKJ56HKXE2 Unit : mm 1148 23 486 486 130 23 7.7 4 194 65 155 144 Space for installation and service φ8 × 48 pcs. (Holes on mounting plate) 712 150 200 or more or more Available space for rear connection 45 Piping cover Hole on wall for rear connection 55 Gas piping φ 15.88 (5/8") 105 φ70 Liquid piping 608 φ 9.52 (3/8") 200 Mounting plate or more 155 Detail of mounting plate Outlet for piping (On both side) 65 10 38 50 144 1018 197.5 155 197.5 25 25 20 20 25 20 20 10 64 59 8 908 65 58 90 Outlet for electric wiring 375 280 ←A 260 55 Drain hose 0.7 m VIEW A (Rear side) 987 FDC-HKXR Model FDKJ71HKXE2 23 Unit : mm 1436 486 387 387 130 23 194 4 7.7 Outlet for piping (On both side) 65 377.5 155 108 Space for installation and service Mounting plate 200 10 38 50 377.5 Detail of mounting plate 150 200 or more or more 45 φ8 × 48 pcs. (Holes on mounting plate) or more 155 108 1306 155 25 25 20 20 25 20 20 8 10 64 59 65 1196 65 58 90 Outlet for electric wiring 375 280 ←A Piping cover Hole on wall for 55 Gas piping φ 9.52 (3/8") rear connection 105 Liquid piping φ70 608 φ 15.88(5/8") 550 Drain hose 0.7 m 55 Available space for rear connection 712 VIEW A (Rear side) (h) Floor standing exposed type (FDFL) Models FDFLJ28HKXE2, 45HKXE2, 71HKXE2 Unit : mm Note (1) Value in ( ) indicates 71 type. Space for installation and service 205 180 23 600 177 Remote-controller mounting part 225 150 or more 166 1000 or more 786 (1071) 150 or more 205 10 126 Slotted hole for wall mounting 4-12×24 Floor piping space or more 1196 (1481) 600 or more Floor Control box 80 220 184 234 315 630 250 Expansion valve box Level adjusting screw (Accessory) 197 223 750 (1035) 93 148 223 98 195 988 Gas piping (Accessory) 28,45 type:φ12.7(1/2") 71 type:φ15.88(5/8") 197 225 32 Floor fixing metal brakcet (Accessory) 10×30 long hole Drain piping Flexible tube PT20A female screw Air filter 806 (1091) 195 Liquid piping 28,45 type:φ6.35(1/4") 71 type:φ9.52(3/8") FDC-HKXR (i) Floor standing hidden type (FDFU) Models FDFUJ28HKXE2, 45HKXE2, 56HKXE2, 71HKXE2 Note (1) Value in ( Unit : mm ) indicates 71 type. Slotted hole for wall mounting 4-12 x 24 Space for installation and service 110 600 1000 126 166 786 (1071) 167 Peri cover Peri cover 45 100 600 100 100 810(1095) 722(1007) 20 225 105 110 Expansion valve box Control box 80 220 184 234 315 630 250 Drain piping Flexible tube PT20A female screw Air filter 30 197 Level adjusting screw (Accessory) 750(1035) 98 32 Floor fixing metal braket (Accessory) 10 x 30 long hole Gas piping (Accessory) 28,45type : ø12.7(1/2") 56,71type : ø15.88(5/8") Liquid piping 28,45type : ø6.35(1/4") 56,71type : ø9.52(3/8") 806(1091) 989 FDC-HKXR (2) Remote controller (Optional parts) Wall 0.3mm2, 3cores (O.D.φ5.6) Wire (Recessed) LCD display Junction box (Locally Purchased) 120 16 Remote controller mounting dimensions 120 60 46 47 17 7 120 89 83.5 For the passage after wiring ♦ Usable JIS box, JIS C 8336 ⋅ Switch box for 1 piece (without cover) (use of the mark hole as illustrated on the left) ⋅ Switch box for 2 pieces (use of the mark hole as illustrated on the left) (without cover) (use of the mark hole as illustrated on the left) (when installing the cover) Notes (1) Allowable length of remote controller cable: 600 m Allowable rang of wire thickness and length Remote controller outline 990 Standard Within 0.3 mm2 0.5 mm2 0.75 mm2 1.25 mm2 2 mm2 × Within 100 m × Within 200 m × Within 300 m × Within 400 m × Within 600 m FDC-HKXR (3) Individual flow divide controller (Optional Part) HPFD01R-E 117.5 Indoor refrigerant piping connection pipe Liquid pipe φ9.52 (3/8") flare. with included different diameter adapter coupling φ6.35 (1/4") pipe Hanging bolt position (M10 provided at site) 61 Indoor connection wire (length 200) (with insert terminal) Outdoor refrigerant piping connection pipe Liquid pipe φ9.52 (3/8") flare. with included different diameter adapter coupling φ6.35 (1/4") pipe 37.5 73.5 Indoor refrigerant piping connection pipe Gas pipe φ15.88 (5/8") flare. included φ12.7 (1/2") different diameter adapter coupling with φ19.05 (3/4") cutoff pipe Accessory discharge gas pipe (with strainer) 51.5 32 32 173 173 265 245 Outdoor refrigerant piping connection pipe Discharge gas pipe φ12.7 (1/2") flare. included different diameter adapter coupling with φ15.88 (5/8") pipe 40 40 Outdoor refrigerant piping connection pipe Intake gas pipe φ15.88 (5/8") flare. included different diameter adapter coupling φ19.05 (3/4") with φ12.7 (1/2") cutoff pipe 37.5 53 77.5 117.5 235 65.5 310 155 (When connected to the included intake gas piping) • Inspection door 150 or more Service space Top Front Inspection door 150 Front or more ( 450) 150 or more Bottom Notes (1) Do not operate the unit without the indoor unit connected (5) Use the indoor unit connection capacity to select a different to the individual flow divide controller. (2) Be sure to install the included strainer in the outdoor discharge gas connection pipe. (3) Do not install the flow divide controller upside down. Install so that the body is level. diameter adapter coupling from the foliowing table. (Use the flare nuts that are included with the flow divide controller.) For indoor gas piping (4) Weight: 6 kg 1 unit OD15.88 ID12.7 ID19.05 Different diameter adapter coupling For indoor For outdoor For outdoor For outdoor liquid piintake gas dischage gas liquid pipping piping piping ing 1 unit 1 unit 1 unit 1 unit OD9.52 ID6.35 OD15.88 ID12.7 ID19.05 OD12.7 ID15.88 OD9.52 ID6.35 991 Wire entry hole (φ50) 15 640 35 36 24 250 850 pass-through hole (φ100) Back 50 Piping and wiring bottom 118 Drain waste water hole (6-φ20) 170 φ19.05 (3/4") Refrigerant discharge gas piping connection pipe Anchor bolt hole (4 locations for M10) 150 250 240 163 80 250 187 168 145 2001: with φ25.4 (1") pipe 2501: with φ28.58 (1 1/8") pipe Refrigerant Intake gas piping connection pipe φ12.7 (1/2") flare Refrigerant liquid piping connection pipe 98 65 ( Installation example L4 L3 L2 L1 ) Suction Suction Service space Dimensions L2 500 200 0 Open I Refrigerant piping exit hole (φ88) II 0 200 500 Open L4 500 200 500 500 III Unit: mm Notes (1) Be sure to fasten down the unit with the anchor bolts. (2) If in a location with strong winds, position the air discharge outlet piping perpendicular to the wind direction. (3) Provide at least 1 m of space above the unit. 100 105 Power supply entry hole (φ50) Dimensions after connecting included refrigerant (Top view) 40 625 Signal wire connection terminal box 50 Drain waste water hose hole (φ45) 645 terminal Models FDCP2001HKXRE2, 2501HKXRE2 52 100 30 nection box 350 50 75 Power supply con- Power supply entry hole (φ50) 110 Power supply entry hole (φ35) Refrigerant gas piping exit hole (φ65) Refrigerant piping exit hole (φ88) 205 100 513 110 Refrigerant liquid piping connection pipe 108 1700 524 143 78 190 150 100 1350 (4) Outdoor unit 15 L3 992 L1 600 FDC-HKXR FDC-HKXR 20.2.4 Exterior appearance (1) Indoor unit (a) Ceiling recessed type (FDT) ● Decorative panel Pearl white (b) 2-way outlet ceiling recessed type (FDTW) Air outlet Air inlet ● Decorative panel (i) Standard type Panel part No. Type Panel color With Auto swing Pearl white TW-PSA-22W-E TW-PSA-32W-E Applicable model FDTW28, 45, 56 type TW-PSA-42W-E FDTW71, 90 type FDTW112, 140 type (ii) Attachment of ceiling material type Panel part No. Type Panel color With Auto swing Misty white TW-PSB-28W-E TW-PSB-38W-E TW-PSB-48W-E Applicable model FDTW28, 45, 56 type FDTW71, 90 type FDTW112, 140 type 993 FDC-HKXR (c) 1-way outlet ceiling recessed type (FDTS) Panel Ceramic white Air inlet grille Ceramic white ● Decorative panel Panel part No. TS-PSA-26W-E TS-PSA-36W-E Type Panel color With Auto swing Misty white Applicable model FDTS22, 28, 36, 45 type FDTS71 type (d) Cassetteria type (FDR) Silent panel type Canvas-duct panel type Ceramic white Ceramic white (e) Satellite ducted type (FDUM) .......................................... Zinc steel plate (f) Ceiling suspension type (FDE) Gray (Vertical fins) Gray (Frame) 994 Ceramic white (Front panel) Ceramic white (Air inlet grille) Ceramic white (Side panel) Ceramic white (Front panel) FDC-HKXR (g) Wall mounted type (FDK) 3 2 No. Parts name 1 Side plate 2 Front panel 3 Air inlet grill 4 Air outlet louver 5 Bottom plate 6 Right and Left louvers Color 1 1 4 6 5 Ceramic white Light gray (h) Floor standing exposed type (FDFL) Dark gray (Air outlet grill) Ceramic white (Body) Black (Bottom plate) (i) Floor standing hidden type (FDFU) ........................ Zinc steel plate (2) Outdoor unit Models FDCP224HKXRE2, 280HKXRE2 Polar white 995 FDE series have external installation as the expansion valve box. Indoor unit B Intake Thermistor (Th1-A) ø9.52 (3/8") - Note (1) The solenoid valve is open during magnetic inductance and closed when there is not magnetic inductance. Open - Closed Open Closed 20VF Open - 20VU - Partial load During discharge temperature and dome bottom temperature control Intake gas piping Brazing 63H2 DPR1 ( ) 20SL D ( 63L SV2 ) 4-way valve (For after heat exchange) Discharge piping thermistor (ThO-D) (Suction) Receiver SV1 Capacity control solenoid valve 20 Full 20 Partial VF load VU load SV3 63H1 D S C Flare connection Dome bottom thermistor (Tho-c) Service valve (With charge port) Compressor Check joint (HP) Service valve 63H4 (with charge port) 63H3 Flange DPR2 20SS E (LP) Fusible plug DPR3 Check joint (liquid) SVS Heat exchange thermistor (ThO-R) Heating Strainer (1) (4) Flow divide controller solenoid valve action chart (3) Function of thermistor ThO-A : For low outside air cooling/heating, frost removal control Power Power CoolHeatsupply supply Blower Detrost ThO-R : For frost removal control ing ing OFF ON ThO-D : For Discharge piping temperature control SVH Closed Closed Closed Open Closed Closed ThO-C : For dome bottom temperature control ThI-R : For fan control during heating SVC Closed Open Open Closed Open Open For frost prevention during cooling Note (1) Including for pauses, stops, and errors. (1) SVL Outside temperature thermistor (ThO-A) (2) Preset point of protective devices 63H1 : 3.24 open, 2.65 closed MPa (33 open, 27 closed kgf/cm2) [for protective] 63H2 : 2.26 open, 2.84 closed MPa (23 open, 29 closed kgf/cm2) [for high-pressure control (Hz decrease)] 63H3 : 2.50 open, 2.11 closed MPa (25.5 open, 21.5 closed kgf/cm2) [for high-pressure decrease control] 63H4 : 1.67 open, 1.86 closed MPa (17 open, 19 closed kgf/cm2) [for high-pressure increase control] 63L : 1.96 open, 2.75 closed MPa (20 open, 28 closed kgf/cm2) [for low-pressure increase control] DPR1,2 : 1.77 open MPa (18 open kgf/cm2) DPR3 : 2.35 open MPa (24 open kgf/cm2) ø12.7 (1/2") Liquid piping Brazing Brazing ø19.05 (3/4") Discharge gas piping 2001 : ø25.4 2501 : ø28.58 Service valve (with charge port) Cooling Models FDCP2001HKXRE2, 2501HKXRE2 SV1 Full load During compressor capacity control SVL SVG SVL SVG To the units in the following order. (A maximum or 8 units can be connected.) SVH SVC SVH SVC Flow divide controller (1) Solenoid valve operation chart Heat exchange thermistor (Th1-R) Air heartexchanger ø15.88 (5/8") Electronic Strainer expansion valve Indoor unit A Flare connection Check joint (Release) 4-way valve (Discharge) (For before heat exchange) Oil separator Refrigerant flow Accumulator 996 Sub-cooling coil Outdoor unit FDC-HKXR 20.2.5 Piping System FDC-HKXR 20.2.6 Selection chart (1) Correct the cooling and heating capacity in accordance with the conditions as follows.The net cooling and heating capacity can be,obtained in the following way. Indoor unit Each indoor unit = System performance Indoor unit capacity Indoor unit capacity when operating simultaneously. Outdoor unit Performance from connected capacity correction coefficient from indoor and outdoor temperature conditions (correction coefficient from piping distance System performance = correction coefficient from difference between indoor and outdoor temperature) (correction coefficient from condensation when heating). Note: Refer to page 997 and 998 for the correction coefficient. (a) Coefficient of cooling and heating capacity in relation to temperatures Heating Cooling 1.1 Heating 1.0 0.9 0.8 0.7 Range in which use is possible 0.6 Outdoor dry bulb temperature (˚CDB) Cooling 1.2 Indoor dry bulb temperature (˚CDB) Performance correction coefficient 1.3 20 22 24 26 43 40 35 30 25 20 26 24 0 –5 14 16 18 Indoor wet bulb temperature (˚CWB) JIS 20 22 27 25 20 15 10 18.5 -10 -5 0 5 10 15 JIS Outdoor wet bulb temperature (˚CWB) (b) Correction of cooling and heating capacity in relation to one way length of refrigerant piping. Equivalent piping length [m] (1) Cooling Heating 5 1.0 1.0 10 0.99 1.0 15 0.975 1.0 20 0.965 1.0 25 0.95 1.0 30 0.94 0.995 35 0.925 0.995 40 0.915 0.99 45 0.9 0.99 50 0.89 0.985 Equivalent piping length [m] Cooling Heating 55 0.875 0.985 60 0.865 0.98 65 0.85 0.98 70 0.84 0.975 75 0.825 0.975 80 0.815 0.97 85 0.8 0.97 90 0.79 0.965 95 0.775 0.965 100 0.765 0.96 Equivalent piping length [m] Cooling Heating 105 0.745 0.96 110 0.74 0.955 115 0.725 0.955 120 0.715 0.95 125 0.7 0.95 Note (1) Equivalent piping length can be obtained by calculating as follows. Equivalent piping length = Real gas piping length + Number of bends in gas piping × Equivalent piping length of bends. Unit : m/one part Equivalent length of each joint Gas piping size Joint (90˚elbow) φ12.7 0.10 φ15.88 0.10 φ19.05 0.15 φ25.4 0.15 φ28.58 0.20 997 FDC-HKXR (c) When the outdoor unit is located at a lower height than the indoor unit in cooling operation and when the outdoor unit is located at a higher height than the indoor unit in heating operation, the following values should be subtracvted from the values in the above table. Height difference between the indoor unit and outdoor unit in the vertical height difference Adjustment coefficient Height difference between the indoor unit and outdoor unit in the vertical height difference Adjustment coefficient 5m 10 m 15 m 20 m 25 m 30 m 0.01 0.02 0.03 0.04 0.05 0.06 35 m 40 m 45 m 50 m 0.07 0.08 0.09 0.10 (d) Correction of heating capacity in relation to the frost on the outdoor unit heat exchanger Air inlet temperature of outdoor unit in ˚C WB Adjustment coefficient -11 -9 -7 -5 -3 -1 1 3 5 0.95 0.94 0.93 0.91 0.88 0.86 0.87 0.92 1.00 The correction factors will change drastically according to weather conditions. So necessary adjustment should be made empirically according to the weather data of the particulsr area. (2) Correction of outdoor unit capacity according to capacity of indoor unit to be operated simultaneously FDCP2001HKXRE2 Total capacity of indoor units operating simultaneously 998 FDC-HKXR FDCP2501HKXRE2 Total capacity of indoor units operating simultaneously Capacity Correction Calculations (The procedure for both cooling and heating is the same.) Example Conditions • Unit (50 Hz) Outdoor unit FDCP2501HKXRE2 1 unit Indoor unit FDTJ90HKXE2 - 1 unit FDTJ140HKXE2 - 1 unit FDTWJ28HKXE2B - 1 unit FDTSJ22HKXE2B - 1 unit • Piping length (Shall be common among units) .......... 60 meters (suitable length) • Difference in height between indoor and ........... 15 meters outdoor units (Outdoor unit is lower) • Air conditions .......... Outdoor air temperature 33˚CDB Indoor temperature 26˚CDB 19 ˚CWB Corrction when cooling? Outdoor unit performance correction 1 Total connection capacity from indoor unit ... 901 unit + 1401 unit + 281 unitt + 221 unit = 280 . . 28kW (From table above) = 2 Performance correction from indoor and outdoor temperatures . 28.5kW 28 1.02 = . 3 Performance correction from piping length and difference in height between indoor and outdoor units . . 23.8kW (Actual performance) 28.5 (0.865 - 0.03) = Performance correction of indoor unit Performance correction of indoor unit = System performance Indoor unit capacity Total capacity of indoor units operating simultaneously [Example] FDTJ90HKXE2 90 . 23.8 =. 7.65kW 280 Performance of indoor unit FDTJ90HKXE2 ................... 7.65kW (Actual performance) FDTJ140HKXE2 ................ 11.9kW (Actual performance) FDTWJ28HKXE2B .......... 2.38kW (Actual performance) FDTSJ22HKXE2B .......... 1.87kW (Actual performance) 999 FDC-HKXR (3) Sensible heat capacity (a) FDT Series Model FDTJ28HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 12 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 2.89 2.83 2.76 2.68 2.60 2.53 2.46 SHC 2.58 2.55 2.52 2.49 2.46 2.43 2.40 18.0°CWB TC 2.98 2.91 2.85 2.77 2.70 2.63 2.56 SHC 2.60 2.57 2.55 2.52 2.49 2.46 2.43 19.0°CWB TC 3.05 2.99 2.92 2.86 2.80 2.72 2.64 SHC 2.61 2.59 2.56 2.54 2.52 2.49 2.46 20.0°CWB TC 3.13 3.07 3.01 2.95 2.88 2.81 2.74 SHC 2.63 2.61 2.58 2.56 2.54 2.51 2.49 21.0°CWB TC 3.21 3.15 3.09 3.02 2.95 2.89 2.83 SHC 2.64 2.62 2.60 2.58 2.55 2.53 2.51 22.0°CWB TC 3.28 3.22 3.16 3.10 3.04 2.98 2.91 SHC 2.6 2.6 2.6 2.5 2.5 2.5 2.5 Model FDTJ36HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 12 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 3.72 3.64 3.55 3.45 3.35 3.25 3.16 SHC 3.19 3.16 3.12 3.08 3.04 3.00 2.96 18.0°CWB TC 3.83 3.75 3.66 3.57 3.47 3.38 3.29 SHC 3.22 3.19 3.15 3.11 3.08 3.04 3.00 19.0°CWB TC 3.93 3.84 3.76 3.68 3.60 3.50 3.40 SHC 3.24 3.20 3.17 3.14 3.11 3.07 3.04 20.0°CWB TC 4.02 3.95 3.87 3.79 3.71 3.61 3.52 SHC 3.25 3.22 3.20 3.17 3.14 3.10 3.07 21.0°CWB TC 4.12 4.05 3.97 3.88 3.80 3.72 3.64 SHC 3.27 3.24 3.21 3.18 3.15 3.13 3.10 22.0°CWB TC 4.21 4.14 4.06 3.99 3.91 3.83 3.75 SHC 3.2 3.2 3.2 3.2 3.1 3.1 3.1 Model FDTJ45HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 15 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 4.65 4.55 4.44 4.31 4.19 4.07 3.95 SHC 3.99 3.95 3.90 3.85 3.80 3.75 3.71 18.0°CWB TC 4.78 4.68 4.58 4.46 4.34 4.23 4.11 SHC 4.02 3.98 3.94 3.89 3.85 3.80 3.76 19.0°CWB TC 4.91 4.80 4.70 4.60 4.50 4.37 4.25 SHC 4.05 4.01 3.97 3.93 3.89 3.84 3.80 20.0°CWB TC 5.03 4.93 4.83 4.73 4.64 4.52 4.40 SHC 4.07 4.03 3.99 3.96 3.92 3.88 3.84 21.0°CWB TC 5.15 5.06 4.96 4.86 4.75 4.65 4.55 SHC 4.09 4.05 4.02 3.98 3.94 3.91 3.87 22.0°CWB TC 5.27 5.18 5.08 4.98 4.88 4.78 4.68 SHC 4.1 4.0 4.0 4.0 3.9 3.9 3.9 Model FDTJ56HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 15 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 5.78 5.66 5.52 5.36 5.21 5.06 4.92 SHC 4.48 4.43 4.36 4.30 4.23 4.17 4.10 18.0°CWB TC 5.95 5.83 5.70 5.55 5.40 5.26 5.11 SHC 4.51 4.46 4.40 4.34 4.28 4.22 4.16 Note (1) Symbols are as follows : 1000 TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 19.0°CWB TC 6.11 5.98 5.85 5.72 5.60 5.44 5.29 SHC 4.53 4.47 4.42 4.37 4.32 4.26 4.19 20.0°CWB TC 6.26 6.14 6.01 5.89 5.77 5.62 5.48 SHC 4.54 4.49 4.44 4.40 4.35 4.29 4.24 21.0°CWB TC 6.41 6.30 6.18 6.04 5.91 5.78 5.66 SHC 4.55 4.51 4.46 4.41 4.36 4.32 4.27 22.0°CWB TC 6.55 6.44 6.32 6.20 6.08 5.95 5.83 SHC 4.5 4.5 4.4 4.4 4.3 4.3 4.2 FDC-HKXR Model FDTJ71KHXE2 Air flow 3 (m /min) 16 Indoor air temperature Outdoor air temp. 17.0°CWB (°CDB) TC 7.33 7.18 7.00 6.80 6.60 6.42 6.23 27 29 31 33 35 37 39 SHC 5.31 5.24 5.15 5.06 4.97 4.89 4.81 18.0°CWB TC 7.55 7.39 7.22 7.04 6.85 6.67 6.48 SHC 5.34 5.27 5.19 5.11 5.03 4.95 4.87 19.0°CWB TC 7.75 7.58 7.41 7.26 7.10 6.90 6.70 SHC 5.35 5.28 5.21 5.14 5.07 4.99 4.91 20.0°CWB TC 7.94 7.78 7.63 7.47 7.31 7.13 6.94 SHC 5.36 5.29 5.23 5.16 5.10 5.02 4.95 21.0°CWB TC 8.13 7.99 7.83 7.66 7.49 7.33 7.16 SHC 5.36 5.30 5.24 5.17 5.11 5.04 4.98 22.0°CWB TC 8.31 8.17 8.02 7.86 7.70 7.55 7.39 SHC 5.3 5.3 5.2 5.1 5.1 5.0 5.0 Model FDTJ90HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 21 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 9.30 9.10 8.87 8.62 8.37 8.14 7.90 SHC 6.82 6.72 6.62 6.51 6.39 6.29 6.19 18.0°CWB TC 9.57 9.37 9.15 8.92 8.69 8.45 8.22 SHC 6.85 6.76 6.67 6.56 6.46 6.36 6.26 19.0°CWB TC 9.82 9.60 9.40 9.20 9.00 8.75 8.50 SHC 6.87 6.78 6.69 6.61 6.52 6.42 6.31 20.0°CWB TC 10.06 9.86 9.67 9.47 9.27 9.04 8.80 SHC 6.88 6.80 6.72 6.64 6.56 6.46 6.37 21.0°CWB TC 10.31 10.13 9.93 9.71 9.50 9.30 9.10 SHC 6.89 6.82 6.74 6.65 6.57 6.49 6.42 22.0°CWB TC 10.53 10.35 10.16 9.96 9.77 9.57 9.37 SHC 6.8 6.8 6.7 6.6 6.5 6.5 6.4 Model FDTJ112HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 28 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 11.57 11.32 11.04 10.73 10.42 10.12 9.83 SHC 8.71 8.60 8.47 8.33 8.20 8.07 7.94 18.0°CWB TC 11.91 11.66 11.39 11.10 10.81 10.52 10.23 SHC 8.76 8.65 8.54 8.41 8.29 8.16 8.04 19.0°CWB TC 12.22 11.95 11.69 11.45 11.20 10.89 10.57 SHC 8.79 8.68 8.57 8.47 8.37 8.24 8.11 20.0°CWB TC 12.52 12.28 12.03 11.78 11.54 11.24 10.95 SHC 8.81 8.71 8.61 8.51 8.42 8.30 8.19 21.0°CWB TC 12.82 12.60 12.35 12.08 11.82 11.57 11.32 SHC 8.82 8.74 8.64 8.54 8.44 8.34 8.25 22.0°CWB TC 13.10 12.88 12.64 12.40 12.15 11.91 11.66 SHC 8.8 8.7 8.6 8.5 8.4 8.3 8.2 Model FDTJ140HKXE2 Air flow 3 (m /min) 30 Indoor air temperature Outdoor air temp. (°CDB) 17.0°CWB TC 14.46 14.15 13.80 13.41 13.02 12.66 12.29 27 29 31 33 35 37 39 SHC 10.29 10.15 9.98 9.80 9.62 9.45 9.28 18.0°CWB TC 14.88 14.57 14.24 13.87 13.51 13.15 12.78 SHC 10.34 10.20 10.04 9.88 9.72 9.55 9.40 19.0°CWB TC 15.27 14.94 14.62 14.31 14.00 13.61 13.22 SHC 10.36 10.21 10.07 9.94 9.81 9.64 9.47 20.0°CWB TC 15.65 15.34 15.04 14.73 14.42 14.06 13.69 SHC 10.37 10.24 10.11 9.98 9.85 9.70 9.55 21.0°CWB TC 16.03 15.75 15.44 15.11 14.77 14.46 14.15 SHC 10.37 10.26 10.13 10.00 9.86 9.74 9.62 22.0°CWB TC 16.38 16.10 15.81 15.50 15.19 14.88 14.57 SHC 10.3 10.2 10.1 10.0 9.8 9.7 9.6 Note (1) Symbols are as follows : TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 1001 FDC-HKXR (b) FDTS Series Model FDTSJ22HKXE2B Air flow 3 (m /min) 11 Indoor air temperature Outdoor air temp. (°CDB) 17.0°CWB TC 2.27 2.22 2.17 2.11 2.05 1.99 1.93 27 29 31 33 35 37 39 SHC 2.04 2.02 2.00 1.98 1.95 1.93 1.91 18.0°CWB TC 2.34 2.29 2.24 2.18 2.12 2.07 2.01 SHC 2.06 2.04 2.02 2.00 1.98 1.95 1.93 19.0°CWB TC 2.40 2.35 2.30 2.25 2.20 2.14 2.08 SHC 2.08 2.06 2.04 2.02 2.00 1.98 1.95 20.0°CWB TC 2.46 2.41 2.36 2.31 2.27 2.21 2.15 SHC 2.09 2.07 2.05 2.03 2.02 2.00 1.98 21.0°CWB TC 2.52 2.48 2.43 2.37 2.32 2.27 2.22 SHC 2.10 2.08 2.07 2.05 2.03 2.01 2.00 22.0°CWB TC 2.57 2.53 2.48 2.44 2.39 2.34 2.29 SHC 2.11 2.09 2.08 2.06 2.04 2.03 2.01 Model FDTSJ28HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 12 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 2.90 2.83 2.77 2.69 2.60 2.54 2.45 SHC 2.58 2.55 2.52 2.49 2.46 2.43 2.40 18.0°CWB TC 2.98 2.92 2.85 2.78 2.72 2.63 2.55 SHC 2.60 2.57 2.55 2.52 2.49 2.46 2.43 19.0°CWB TC 3.06 3.00 2.93 2.87 2.80 2.73 2.65 SHC 2.62 2.59 2.57 2.54 2.52 2.49 2.46 20.0°CWB TC 3.12 3.07 3.02 2.95 2.88 2.82 2.75 SHC 2.63 2.61 2.59 2.56 2.54 2.52 2.49 21.0°CWB TC 3.21 3.14 3.09 3.04 2.97 2.90 2.83 SHC 2.64 2.62 2.60 2.58 2.56 2.54 2.51 22.0°CWB TC 3.29 3.23 3.16 3.10 3.05 2.98 2.92 SHC 2.66 2.64 2.61 2.59 2.58 2.55 2.53 Model FDTSJ36HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 12 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 3.73 3.64 3.56 3.46 3.35 3.26 3.15 SHC 3.20 3.16 3.13 3.09 3.04 3.01 2.96 18.0°CWB TC 3.84 3.75 3.66 3.58 3.49 3.38 3.28 SHC 3.22 3.19 3.15 3.12 3.08 3.04 3.00 19.0°CWB TC 3.94 3.86 3.77 3.69 3.60 3.51 3.41 SHC 3.24 3.21 3.18 3.15 3.11 3.08 3.04 20.0°CWB TC 4.02 3.95 3.88 3.79 3.71 3.62 3.54 SHC 3.25 3.23 3.20 3.17 3.14 3.11 3.07 21.0°CWB TC 4.13 4.04 3.97 3.90 3.82 3.73 3.64 SHC 3.27 3.24 3.21 3.19 3.16 3.13 3.10 22.0°CWB TC 4.23 4.15 4.06 3.98 3.92 3.84 3.75 SHC 3.28 3.26 3.23 3.20 3.18 3.15 3.12 Model FDTSJ45HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 14 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 4.66 4.55 4.45 4.33 4.19 4.08 3.94 SHC 3.86 3.82 3.77 3.72 3.66 3.62 3.56 18.0°CWB TC 4.80 4.69 4.58 4.47 4.37 4.22 4.10 SHC 3.89 3.85 3.80 3.76 3.71 3.66 3.61 Note (1) Symbols are as follows : 1002 TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 19.0°CWB TC 4.92 4.82 4.72 4.61 4.50 4.39 4.26 SHC 3.91 3.87 3.83 3.79 3.75 3.70 3.65 20.0°CWB TC 5.02 4.94 4.85 4.74 4.64 4.53 4.42 SHC 3.92 3.89 3.85 3.81 3.77 3.73 3.69 21.0°CWB TC 5.16 5.05 4.96 4.88 4.77 4.66 4.55 SHC 3.94 3.90 3.87 3.84 3.80 3.76 3.72 22.0°CWB TC 5.28 5.18 5.08 4.98 4.91 4.80 4.69 SHC 3.95 3.92 3.88 3.85 3.82 3.78 3.75 FDC-HKXR Model FDTSJ71HKXE2B Air flow 3 (m /min) 18 Indoor air temperature Outdoor air temp. (°CDB) 17.0°CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 27 29 31 33 35 37 39 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0°CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 19.0°CWB TC 7.77 7.61 7.44 7.27 7.10 6.93 6.72 SHC 5.61 5.55 5.48 5.41 5.34 5.27 5.18 20.0°CWB TC 7.92 7.80 7.65 7.48 7.31 7.14 6.97 SHC 5.61 5.56 5.50 5.44 5.37 5.30 5.24 21.0°CWB TC 8.14 7.97 7.82 7.70 7.53 7.36 7.19 SHC 5.63 5.57 5.51 5.46 5.40 5.33 5.27 22.0°CWB TC 8.34 8.18 8.01 7.85 7.74 7.57 7.40 SHC 5.64 5.58 5.52 5.46 5.42 5.36 5.30 (c) FDR Series Model FDRJ22HKXE2 Air flow 3 (m /min) 10 Indoor air temperature Outdoor air temp. (°CDB) 17.0°CWB TC 2.28 2.23 2.17 2.12 2.05 1.99 1.93 27 29 31 33 35 37 39 SHC 2.05 2.02 2.00 1.98 1.95 1.93 1.90 18.0°CWB TC 2.35 2.29 2.24 2.19 2.13 2.06 2.01 SHC 2.06 2.04 2.02 2.00 1.98 1.95 1.93 19.0°CWB TC 2.41 2.36 2.31 2.25 2.20 2.15 2.08 SHC 2.08 2.06 2.04 2.02 2.00 1.98 1.96 20.0°CWB TC 2.46 2.42 2.37 2.32 2.27 2.21 2.16 SHC 2.09 2.07 2.06 2.04 2.02 2.00 1.98 21.0°CWB TC 2.52 2.47 2.42 2.38 2.33 2.28 2.23 SHC 2.10 2.08 2.06 2.05 2.03 2.01 2.00 22.0°CWB TC 2.58 2.53 2.48 2.43 2.40 2.35 2.29 SHC 2.11 2.09 2.08 2.06 2.05 2.03 2.01 Model FDRJ28HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 12 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 2.90 2.83 2.77 2.69 2.60 2.54 2.45 SHC 2.58 2.55 2.52 2.49 2.46 2.43 2.40 18.0°CWB TC 2.98 2.92 2.85 2.78 2.72 2.63 2.55 SHC 2.60 2.57 2.55 2.52 2.49 2.46 2.43 19.0°CWB TC 3.06 3.00 2.93 2.87 2.80 2.73 2.65 SHC 2.62 2.59 2.57 2.54 2.52 2.49 2.46 20.0°CWB TC 3.12 3.07 3.02 2.95 2.88 2.82 2.75 SHC 2.63 2.61 2.59 2.56 2.54 2.52 2.49 21.0°CWB TC 3.21 3.14 3.09 3.04 2.97 2.90 2.83 SHC 2.64 2.62 2.60 2.58 2.56 2.54 2.51 22.0°CWB TC 3.29 3.23 3.16 3.10 3.05 2.98 2.92 SHC 2.66 2.64 2.61 2.59 2.58 2.55 2.53 Model FDRJ45HKXE2 Air flow 3 (m /min) 14 Indoor air temperature Outdoor air temp. (°CDB) 17.0°CWB TC 4.66 4.55 4.45 4.33 4.19 4.08 3.94 27 29 31 33 35 37 39 SHC 3.86 3.82 3.77 3.72 3.66 3.62 3.56 18.0°CWB TC 4.80 4.69 4.58 4.47 4.37 4.22 4.10 SHC 3.89 3.85 3.80 3.76 3.71 3.66 3.61 19.0°CWB TC 4.92 4.82 4.72 4.61 4.50 4.39 4.26 SHC 3.91 3.87 3.83 3.79 3.75 3.70 3.65 20.0°CWB TC 5.02 4.94 4.85 4.74 4.64 4.53 4.42 SHC 3.92 3.89 3.85 3.81 3.77 3.73 3.69 21.0°CWB TC 5.16 5.05 4.96 4.88 4.77 4.66 4.55 SHC 3.94 3.90 3.87 3.84 3.80 3.76 3.72 22.0°CWB TC 5.28 5.18 5.08 4.98 4.91 4.80 4.69 SHC 3.95 3.92 3.88 3.85 3.82 3.78 3.75 Note (1) Symbols are as follows : TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 1003 FDC-HKXR Model FDRJ56HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 14 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 5.80 5.67 5.53 5.39 5.21 5.07 4.91 SHC 4.36 4.30 4.24 4.18 4.10 4.04 3.97 18.0°CWB TC 5.97 5.84 5.70 5.57 5.43 5.25 5.11 SHC 4.39 4.33 4.27 4.21 4.16 4.08 4.02 19.0°CWB TC 6.13 6.00 5.87 5.73 5.60 5.47 5.30 SHC 4.40 4.35 4.29 4.24 4.18 4.13 4.06 20.0°CWB TC 6.25 6.15 6.04 5.90 5.77 5.63 5.50 SHC 4.40 4.36 4.32 4.26 4.21 4.16 4.10 21.0°CWB TC 6.42 6.28 6.17 6.07 5.94 5.80 5.67 SHC 4.41 4.36 4.32 4.28 4.23 4.18 4.13 22.0°CWB TC 6.57 6.45 6.32 6.19 6.10 5.97 5.84 SHC 4.42 4.37 4.32 4.28 4.25 4.20 4.15 Model FDRJ71HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 18 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0°CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 19.0°CWB TC 7.77 7.61 7.44 7.27 7.10 6.93 6.72 SHC 5.61 5.55 5.48 5.41 5.34 5.27 5.18 20.0°CWB TC 7.92 7.80 7.65 7.48 7.31 7.14 6.97 SHC 5.61 5.56 5.50 5.44 5.37 5.30 5.24 21.0°CWB TC 8.14 7.97 7.82 7.70 7.53 7.36 7.19 SHC 5.63 5.57 5.51 5.46 5.40 5.33 5.27 22.0°CWB TC 8.34 8.18 8.01 7.85 7.74 7.57 7.40 SHC 5.64 5.58 5.52 5.46 5.42 5.36 5.30 Model FDRJ90HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 20 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 9.32 9.11 8.89 8.66 8.37 8.15 7.88 SHC 6.71 6.61 6.51 6.40 6.27 6.17 6.05 18.0°CWB TC 9.59 9.38 9.16 8.95 8.73 8.44 8.21 SHC 6.74 6.64 6.55 6.45 6.36 6.23 6.13 19.0°CWB TC 9.85 9.65 9.43 9.22 9.00 8.78 8.51 SHC 6.76 6.67 6.58 6.49 6.39 6.30 6.19 20.0°CWB TC 10.04 9.88 9.70 9.49 9.27 9.05 8.84 SHC 6.75 6.68 6.60 6.52 6.43 6.34 6.25 21.0°CWB TC 10.31 10.10 9.92 9.76 9.54 9.32 9.11 SHC 6.76 6.67 6.60 6.54 6.45 6.37 6.28 22.0°CWB TC 10.57 10.37 10.15 9.95 9.81 9.59 9.38 SHC 6.76 6.69 6.60 6.53 6.47 6.39 6.31 Model FDRJ112HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 28 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 11.60 11.33 11.07 10.77 10.42 10.15 9.81 SHC 8.72 8.60 8.48 8.35 8.20 8.08 7.93 18.0°CWB TC 11.94 11.67 11.40 11.13 10.86 10.51 10.21 SHC 8.77 8.66 8.54 8.42 8.31 8.16 8.04 Note (1) Symbols are as follows : 1004 TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 19.0°CWB TC 12.25 12.01 11.74 11.47 11.20 10.93 10.60 SHC 8.80 8.70 8.59 8.48 8.37 8.26 8.12 20.0°CWB TC 12.50 12.30 12.07 11.80 11.54 11.27 11.00 SHC 8.80 8.72 8.63 8.52 8.42 8.31 8.20 21.0°CWB TC 12.84 12.57 12.34 12.14 11.87 11.60 11.33 SHC 8.83 8.72 8.64 8.56 8.46 8.36 8.26 22.0°CWB TC 13.15 12.90 12.63 12.39 12.21 11.94 11.67 SHC 8.84 8.75 8.65 8.56 8.49 8.39 8.30 FDC-HKXR Model FDRJ140HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 34 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 14.50 14.17 13.83 13.47 13.02 12.68 12.26 SHC 10.78 10.63 10.48 10.31 10.12 9.97 9.78 18.0°CWB TC 14.92 14.59 14.25 13.92 13.58 13.13 12.77 SHC 10.84 10.69 10.55 10.40 10.26 10.07 9.91 19.0°CWB TC 15.32 15.01 14.67 14.34 14.00 13.66 13.24 SHC 10.88 10.75 10.60 10.46 10.32 10.19 10.01 20.0°CWB TC 15.62 15.37 15.09 14.76 14.42 14.08 13.75 SHC 10.87 10.77 10.65 10.52 10.38 10.25 10.12 21.0°CWB TC 16.04 15.71 15.43 15.18 14.84 14.50 14.17 SHC 10.90 10.77 10.66 10.56 10.43 10.30 10.18 22.0°CWB TC 16.44 16.13 15.79 15.48 15.26 14.92 14.59 SHC 10.91 10.80 10.67 10.56 10.47 10.35 10.23 (d) FDUM Series Model FDUMJ36HKXE2 Air flow 3 (m /min) 12 Indoor air temperature Outdoor air temp. 17.0°CWB (°CDB) TC 3.73 3.64 3.56 3.46 3.35 3.26 3.15 27 29 31 33 35 37 39 SHC 3.20 3.16 3.13 3.09 3.04 3.01 2.96 18.0°CWB TC 3.84 3.75 3.66 3.58 3.49 3.38 3.28 SHC 3.22 3.19 3.15 3.12 3.08 3.04 3.00 19.0°CWB TC 3.94 3.86 3.77 3.69 3.60 3.51 3.41 SHC 3.24 3.21 3.18 3.15 3.11 3.08 3.04 20.0°CWB TC 4.02 3.95 3.88 3.79 3.71 3.62 3.54 SHC 3.25 3.23 3.20 3.17 3.14 3.11 3.07 21.0°CWB TC 4.13 4.04 3.97 3.90 3.82 3.73 3.64 SHC 3.27 3.24 3.21 3.19 3.16 3.13 3.10 22.0°CWB TC 4.23 4.15 4.06 3.98 3.92 3.84 3.75 SHC 3.28 3.26 3.23 3.20 3.18 3.15 3.12 Model FDUMJ45HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 14 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 4.66 4.55 4.45 4.33 4.19 4.08 3.94 SHC 3.86 3.82 3.77 3.72 3.66 3.62 3.56 18.0°CWB TC 4.80 4.69 4.58 4.47 4.37 4.22 4.10 SHC 3.89 3.85 3.80 3.76 3.71 3.66 3.61 19.0°CWB TC 4.92 4.82 4.72 4.61 4.50 4.39 4.26 SHC 3.91 3.87 3.83 3.79 3.75 3.70 3.65 20.0°CWB TC 5.02 4.94 4.85 4.74 4.64 4.53 4.42 SHC 3.92 3.89 3.85 3.81 3.77 3.73 3.69 21.0°CWB TC 5.16 5.05 4.96 4.88 4.77 4.66 4.55 SHC 3.94 3.90 3.87 3.84 3.80 3.76 3.72 22.0°CWB TC 5.28 5.18 5.08 4.98 4.91 4.80 4.69 SHC 3.95 3.92 3.88 3.85 3.82 3.78 3.75 Model FDUMJ56HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 14 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 5.80 5.67 5.53 5.39 5.21 5.07 4.91 SHC 4.36 4.30 4.24 4.18 4.10 4.04 3.97 18.0°CWB TC 5.97 5.84 5.70 5.57 5.43 5.25 5.11 SHC 4.39 4.33 4.27 4.21 4.16 4.08 4.02 19.0°CWB TC 6.13 6.00 5.87 5.73 5.60 5.47 5.30 SHC 4.40 4.35 4.29 4.24 4.18 4.13 4.06 20.0°CWB TC 6.25 6.15 6.04 5.90 5.77 5.63 5.50 SHC 4.40 4.36 4.32 4.26 4.21 4.16 4.10 21.0°CWB TC 6.42 6.28 6.17 6.07 5.94 5.80 5.67 SHC 4.41 4.36 4.32 4.28 4.23 4.18 4.13 22.0°CWB TC 6.57 6.45 6.32 6.19 6.10 5.97 5.84 SHC 4.42 4.37 4.32 4.28 4.25 4.20 4.15 Note (1) Symbols are as follows : TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 1005 FDC-HKXR Model FDUMJ71HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 18 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0°CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 19.0°CWB TC 7.77 7.61 7.44 7.27 7.10 6.93 6.72 SHC 5.61 5.55 5.48 5.41 5.34 5.27 5.18 20.0°CWB TC 7.92 7.80 7.65 7.48 7.31 7.14 6.97 SHC 5.61 5.56 5.50 5.44 5.37 5.30 5.24 21.0°CWB TC 8.14 7.97 7.82 7.70 7.53 7.36 7.19 SHC 5.63 5.57 5.51 5.46 5.40 5.33 5.27 22.0°CWB TC 8.34 8.18 8.01 7.85 7.74 7.57 7.40 SHC 5.64 5.58 5.52 5.46 5.42 5.36 5.30 Model FDUMJ90HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 20 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 9.32 9.11 8.89 8.66 8.37 8.15 7.88 SHC 6.71 6.61 6.51 6.40 6.27 6.17 6.05 18.0°CWB TC 9.59 9.38 9.16 8.95 8.73 8.44 8.21 SHC 6.74 6.64 6.55 6.45 6.36 6.23 6.13 19.0°CWB TC 9.85 9.65 9.43 9.22 9.00 8.78 8.51 SHC 6.76 6.67 6.58 6.49 6.39 6.30 6.19 20.0°CWB TC 10.04 9.88 9.70 9.49 9.27 9.05 8.84 SHC 6.75 6.68 6.60 6.52 6.43 6.34 6.25 21.0°CWB TC 10.31 10.10 9.92 9.76 9.54 9.32 9.11 SHC 6.76 6.67 6.60 6.54 6.45 6.37 6.28 22.0°CWB TC 10.57 10.37 10.15 9.95 9.81 9.59 9.38 SHC 6.76 6.69 6.60 6.53 6.47 6.39 6.31 Model FDUMJ112HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 28 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 11.60 11.33 11.07 10.77 10.42 10.15 9.81 SHC 8.72 8.60 8.48 8.35 8.20 8.08 7.93 18.0°CWB TC 11.94 11.67 11.40 11.13 10.86 10.51 10.21 SHC 8.77 8.66 8.54 8.42 8.31 8.16 8.04 19.0°CWB TC 12.25 12.01 11.74 11.47 11.20 10.93 10.60 SHC 8.80 8.70 8.59 8.48 8.37 8.26 8.12 20.0°CWB TC 12.50 12.30 12.07 11.80 11.54 11.27 11.00 SHC 8.80 8.72 8.63 8.52 8.42 8.31 8.20 21.0°CWB TC 12.84 12.57 12.34 12.14 11.87 11.60 11.33 SHC 8.83 8.72 8.64 8.56 8.46 8.36 8.26 22.0°CWB TC 13.15 12.90 12.63 12.39 12.21 11.94 11.67 SHC 8.84 8.75 8.65 8.56 8.49 8.39 8.30 Model FDUMJ140HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 34 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 14.50 14.17 13.83 13.47 13.02 12.68 12.26 SHC 10.78 10.63 10.48 10.31 10.12 9.97 9.78 18.0°CWB TC 14.92 14.59 14.25 13.92 13.58 13.13 12.77 SHC 10.84 10.69 10.55 10.40 10.26 10.07 9.91 Note (1) Symbols are as follows : 1006 TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 19.0°CWB TC 15.32 15.01 14.67 14.34 14.00 13.66 13.24 SHC 10.88 10.75 10.60 10.46 10.32 10.19 10.01 20.0°CWB TC 15.62 15.37 15.09 14.76 14.42 14.08 13.75 SHC 10.87 10.77 10.65 10.52 10.38 10.25 10.12 21.0°CWB TC 16.04 15.71 15.43 15.18 14.84 14.50 14.17 SHC 10.90 10.77 10.66 10.56 10.43 10.30 10.18 22.0°CWB TC 16.44 16.13 15.79 15.48 15.26 14.92 14.59 SHC 10.91 10.80 10.67 10.56 10.47 10.35 10.23 FDC-HKXR (e) FDE Series Model FDEJ36HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 14 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 3.73 3.64 3.56 3.46 3.35 3.26 3.15 SHC 3.34 3.30 3.26 3.23 3.18 3.15 3.10 18.0°CWB TC 3.84 3.75 3.66 3.58 3.49 3.38 3.28 SHC 3.36 3.33 3.30 3.26 3.23 3.18 3.15 19.0°CWB TC 3.94 3.86 3.77 3.69 3.60 3.51 3.41 SHC 3.39 3.36 3.32 3.29 3.26 3.23 3.19 20.0°CWB TC 4.02 3.95 3.88 3.79 3.71 3.62 3.54 SHC 3.40 3.38 3.35 3.32 3.29 3.26 3.23 21.0°CWB TC 4.13 4.04 3.97 3.90 3.82 3.73 3.64 SHC 3.42 3.39 3.37 3.34 3.31 3.28 3.25 22.0°CWB TC 4.23 4.15 4.06 3.98 3.92 3.84 3.75 SHC 3.44 3.41 3.38 3.35 3.34 3.31 3.28 Model FDEJ45HKXE2B Air flow 3 (m /min) 14 Indoor air temperature Outdoor air temp. 17.0°CWB (°CDB) TC 4.66 4.55 4.45 4.33 4.19 4.08 3.94 27 29 31 33 35 37 39 SHC 3.86 3.82 3.77 3.72 3.66 3.62 3.56 18.0°CWB TC 4.80 4.69 4.58 4.47 4.37 4.22 4.10 SHC 3.89 3.85 3.80 3.76 3.71 3.66 3.61 19.0°CWB TC 4.92 4.82 4.72 4.61 4.50 4.39 4.26 SHC 3.91 3.87 3.83 3.79 3.75 3.70 3.65 20.0°CWB TC 5.02 4.94 4.85 4.74 4.64 4.53 4.42 SHC 3.92 3.89 3.85 3.81 3.77 3.73 3.69 21.0°CWB TC 5.16 5.05 4.96 4.88 4.77 4.66 4.55 SHC 3.94 3.90 3.87 3.84 3.80 3.76 3.72 22.0°CWB TC 5.28 5.18 5.08 4.98 4.91 4.80 4.69 SHC 3.95 3.92 3.88 3.85 3.82 3.78 3.75 Model FDEJ56HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 14 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 5.80 5.67 5.53 5.39 5.21 5.07 4.91 SHC 4.36 4.30 4.24 4.18 4.10 4.04 3.97 18.0°CWB TC 5.97 5.84 5.70 5.57 5.43 5.25 5.11 SHC 4.39 4.33 4.27 4.21 4.16 4.08 4.02 19.0°CWB TC 6.13 6.00 5.87 5.73 5.60 5.47 5.30 SHC 4.40 4.35 4.29 4.24 4.18 4.13 4.06 20.0°CWB TC 6.25 6.15 6.04 5.90 5.77 5.63 5.50 SHC 4.40 4.36 4.32 4.26 4.21 4.16 4.10 21.0°CWB TC 6.42 6.28 6.17 6.07 5.94 5.80 5.67 SHC 4.41 4.36 4.32 4.28 4.23 4.18 4.13 22.0°CWB TC 6.57 6.45 6.32 6.19 6.10 5.97 5.84 SHC 4.42 4.37 4.32 4.28 4.25 4.20 4.15 Model FDEJ71HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 18 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0°CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 19.0°CWB TC 7.77 7.61 7.44 7.27 7.10 6.93 6.72 SHC 5.61 5.55 5.48 5.41 5.34 5.27 5.18 20.0°CWB TC 7.92 7.80 7.65 7.48 7.31 7.14 6.97 SHC 5.61 5.56 5.50 5.44 5.37 5.30 5.24 21.0°CWB TC 8.14 7.97 7.82 7.70 7.53 7.36 7.19 SHC 5.63 5.57 5.51 5.46 5.40 5.33 5.27 22.0°CWB TC 8.34 8.18 8.01 7.85 7.74 7.57 7.40 SHC 5.64 5.58 5.52 5.46 5.42 5.36 5.30 Note (1) Symbols are as follows : TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 1007 FDC-HKXR Model FDEJ112HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 28 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 11.60 11.33 11.07 10.77 10.42 10.15 9.81 SHC 8.72 8.60 8.48 8.35 8.20 8.08 7.93 18.0°CWB TC 11.94 11.67 11.40 11.13 10.86 10.51 10.21 SHC 8.77 8.66 8.54 8.42 8.31 8.16 8.04 19.0°CWB TC 12.25 12.01 11.74 11.47 11.20 10.93 10.60 SHC 8.80 8.70 8.59 8.48 8.37 8.26 8.12 20.0°CWB TC 12.50 12.30 12.07 11.80 11.54 11.27 11.00 SHC 8.80 8.72 8.63 8.52 8.42 8.31 8.20 21.0°CWB TC 12.84 12.57 12.34 12.14 11.87 11.60 11.33 SHC 8.83 8.72 8.64 8.56 8.46 8.36 8.26 22.0°CWB TC 13.15 12.90 12.63 12.39 12.21 11.94 11.67 SHC 8.84 8.75 8.65 8.56 8.49 8.39 8.30 Model FDEJ140HKXE2B Air flow 3 (m /min) Outdoor air temp. (°CDB) 34 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 14.50 14.17 13.83 13.47 13.02 12.68 12.26 SHC 10.78 10.63 10.48 10.31 10.12 9.97 9.78 18.0°CWB TC 14.92 14.59 14.25 13.92 13.58 13.13 12.77 SHC 10.84 10.69 10.55 10.40 10.26 10.07 9.91 19.0°CWB TC 15.32 15.01 14.67 14.34 14.00 13.66 13.24 SHC 10.88 10.75 10.60 10.46 10.32 10.19 10.01 20.0°CWB TC 15.62 15.37 15.09 14.76 14.42 14.08 13.75 SHC 10.87 10.77 10.65 10.52 10.38 10.25 10.12 21.0°CWB TC 16.04 15.71 15.43 15.18 14.84 14.50 14.17 SHC 10.90 10.77 10.66 10.56 10.43 10.30 10.18 22.0°CWB TC 16.44 16.13 15.79 15.48 15.26 14.92 14.59 SHC 10.91 10.80 10.67 10.56 10.47 10.35 10.23 (f) FDK Series Model FDKJ22HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 9 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 2.27 2.22 2.17 2.11 2.05 1.99 1.93 SHC 2.04 2.02 2.00 1.98 1.95 1.93 1.91 18.0°CWB TC 2.34 2.29 2.24 2.18 2.12 2.07 2.01 SHC 2.06 2.04 2.02 2.00 1.98 1.95 1.93 19.0°CWB TC 2.40 2.35 2.30 2.25 2.20 2.14 2.08 SHC 2.08 2.06 2.04 2.02 2.00 1.98 1.95 20.0°CWB TC 2.46 2.41 2.36 2.31 2.27 2.21 2.15 SHC 2.09 2.07 2.05 2.03 2.02 2.00 1.98 21.0°CWB TC 2.52 2.48 2.43 2.37 2.32 2.27 2.22 SHC 2.10 2.08 2.07 2.05 2.03 2.01 2.00 22.0°CWB TC 2.57 2.53 2.48 2.44 2.39 2.34 2.29 SHC 2.11 2.09 2.08 2.06 2.04 2.03 2.01 Model FDKJ28HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 10 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 2.90 2.83 2.77 2.69 2.60 2.54 2.45 SHC 2.58 2.55 2.52 2.49 2.46 2.43 2.40 18.0°CWB TC 2.98 2.92 2.85 2.78 2.72 2.63 2.55 SHC 2.60 2.57 2.55 2.52 2.49 2.46 2.43 Note (1) Symbols are as follows : 1008 TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 19.0°CWB TC 3.06 3.00 2.93 2.87 2.80 2.73 2.65 SHC 2.62 2.59 2.57 2.54 2.52 2.49 2.46 20.0°CWB TC 3.12 3.07 3.02 2.95 2.88 2.82 2.75 SHC 2.63 2.61 2.59 2.56 2.54 2.52 2.49 21.0°CWB TC 3.21 3.14 3.09 3.04 2.97 2.90 2.83 SHC 2.64 2.62 2.60 2.58 2.56 2.54 2.51 22.0°CWB TC 3.29 3.23 3.16 3.10 3.05 2.98 2.92 SHC 2.66 2.64 2.61 2.59 2.58 2.55 2.53 FDC-HKXR Model FDKJ36HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 10 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 3.73 3.64 3.56 3.46 3.35 3.26 3.15 SHC 2.93 2.89 2.86 2.82 2.77 2.73 2.68 18.0°CWB TC 3.84 3.75 3.66 3.58 3.49 3.38 3.28 SHC 2.95 2.91 2.88 2.84 2.81 2.76 2.72 19.0°CWB TC 3.94 3.86 3.77 3.69 3.60 3.51 3.41 SHC 2.96 2.93 2.90 2.86 2.83 2.79 2.75 20.0°CWB TC 4.02 3.95 3.88 3.79 3.71 3.62 3.54 SHC 2.97 2.94 2.91 2.88 2.85 2.81 2.78 21.0°CWB TC 4.13 4.04 3.97 3.90 3.82 3.73 3.64 SHC 2.98 2.95 2.92 2.89 2.86 2.83 2.80 22.0°CWB TC 4.23 4.15 4.06 3.98 3.92 3.84 3.75 SHC 2.98 2.96 2.93 2.90 2.88 2.85 2.82 Model FDKJ45HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 11.5 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 4.66 4.55 4.45 4.33 4.19 4.08 3.94 SHC 3.54 3.49 3.44 3.39 3.33 3.28 3.22 18.0°CWB TC 4.80 4.69 4.58 4.47 4.37 4.22 4.10 SHC 3.56 3.51 3.46 3.42 3.37 3.31 3.26 19.0°CWB TC 4.92 4.82 4.72 4.61 4.50 4.39 4.26 SHC 3.57 3.53 3.48 3.44 3.40 3.35 3.30 20.0°CWB TC 5.02 4.94 4.85 4.74 4.64 4.53 4.42 SHC 3.57 3.54 3.50 3.46 3.42 3.37 3.33 21.0°CWB TC 5.16 5.05 4.96 4.88 4.77 4.66 4.55 SHC 3.58 3.54 3.51 3.47 3.43 3.39 3.35 22.0°CWB TC 5.28 5.18 5.08 4.98 4.91 4.80 4.69 SHC 3.59 3.55 3.51 3.47 3.45 3.41 3.37 Model FDKJ56HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 17 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 5.80 5.67 5.53 5.39 5.21 5.07 4.91 SHC 4.75 4.69 4.64 4.57 4.50 4.44 4.37 18.0°CWB TC 5.97 5.84 5.70 5.57 5.43 5.25 5.11 SHC 4.78 4.73 4.67 4.62 4.56 4.49 4.43 19.0°CWB TC 6.13 6.00 5.87 5.73 5.60 5.47 5.30 SHC 4.81 4.76 4.71 4.65 4.60 4.55 4.48 20.0°CWB TC 6.25 6.15 6.04 5.90 5.77 5.63 5.50 SHC 4.82 4.78 4.74 4.69 4.64 4.59 4.54 21.0°CWB TC 6.42 6.28 6.17 6.07 5.94 5.80 5.67 SHC 4.84 4.79 4.75 4.71 4.66 4.62 4.57 22.0°CWB TC 6.57 6.45 6.32 6.19 6.10 5.97 5.84 SHC 4.86 4.81 4.77 4.72 4.69 4.65 4.60 Model FDKJ71HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 21 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.95 5.87 5.80 5.72 5.63 5.56 5.47 18.0°CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.99 5.92 5.85 5.78 5.71 5.62 5.54 19.0°CWB TC 7.77 7.61 7.44 7.27 7.10 6.93 6.72 SHC 6.02 5.96 5.89 5.82 5.75 5.69 5.61 20.0°CWB TC 7.92 7.80 7.65 7.48 7.31 7.14 6.97 SHC 6.03 5.98 5.93 5.86 5.80 5.73 5.67 21.0°CWB TC 8.14 7.97 7.82 7.70 7.53 7.36 7.19 SHC 6.06 5.99 5.94 5.89 5.83 5.77 5.71 22.0°CWB TC 8.34 8.18 8.01 7.85 7.74 7.57 7.40 SHC 6.07 6.02 5.96 5.90 5.86 5.81 5.75 Note (1) Symbols are as follows : TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 1009 FDC-HKXR (g) FDFL, FDFU Series Models FDFLJ28HKXE2, FDFUJ28HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 12 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 2.90 2.83 2.77 2.69 2.60 2.54 2.45 SHC 2.58 2.55 2.52 2.49 2.46 2.43 2.40 18.0°CWB TC 2.98 2.92 2.85 2.78 2.72 2.63 2.55 SHC 2.60 2.57 2.55 2.52 2.49 2.46 2.43 19.0°CWB TC 3.06 3.00 2.93 2.87 2.80 2.73 2.65 SHC 2.62 2.59 2.57 2.54 2.52 2.49 2.46 20.0°CWB TC 3.12 3.07 3.02 2.95 2.88 2.82 2.75 SHC 2.63 2.61 2.59 2.56 2.54 2.52 2.49 21.0°CWB TC 3.21 3.14 3.09 3.04 2.97 2.90 2.83 SHC 2.64 2.62 2.60 2.58 2.56 2.54 2.51 22.0°CWB TC 3.29 3.23 3.16 3.10 3.05 2.98 2.92 SHC 2.66 2.64 2.61 2.59 2.58 2.55 2.53 Models FDFLJ45HKXE2, FDFUJ45HKXE2 Air flow 3 (m /min) 14 Indoor air temperature Outdoor air temp. (°CDB) 17.0°CWB TC 4.66 4.55 4.45 4.33 4.19 4.08 3.94 27 29 31 33 35 37 39 SHC 3.86 3.82 3.77 3.72 3.66 3.62 3.56 18.0°CWB TC 4.80 4.69 4.58 4.47 4.37 4.22 4.10 SHC 3.89 3.85 3.80 3.76 3.71 3.66 3.61 19.0°CWB TC 4.92 4.82 4.72 4.61 4.50 4.39 4.26 SHC 3.91 3.87 3.83 3.79 3.75 3.70 3.65 20.0°CWB TC 5.02 4.94 4.85 4.74 4.64 4.53 4.42 SHC 3.92 3.89 3.85 3.81 3.77 3.73 3.69 21.0°CWB TC 5.16 5.05 4.96 4.88 4.77 4.66 4.55 SHC 3.94 3.90 3.87 3.84 3.80 3.76 3.72 22.0°CWB TC 5.28 5.18 5.08 4.98 4.91 4.80 4.69 SHC 3.95 3.92 3.88 3.85 3.82 3.78 3.75 Models FDFLJ71HKXE2, FDFUJ71HKXE2 Air flow 3 (m /min) Outdoor air temp. (°CDB) 18 27 29 31 33 35 37 39 Indoor air temperature 17.0°CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0°CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 Note (1) Symbols are as follows : 1010 TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) 19.0°CWB TC 7.77 7.61 7.44 7.27 7.10 6.93 6.72 SHC 5.61 5.55 5.48 5.41 5.34 5.27 5.18 20.0°CWB TC 7.92 7.80 7.65 7.48 7.31 7.14 6.97 SHC 5.61 5.56 5.50 5.44 5.37 5.30 5.24 21.0°CWB TC 8.14 7.97 7.82 7.70 7.53 7.36 7.19 SHC 5.63 5.57 5.51 5.46 5.40 5.33 5.27 22.0°CWB TC 8.34 8.18 8.01 7.85 7.74 7.57 7.40 SHC 5.64 5.58 5.52 5.46 5.42 5.36 5.30 FDC-HKXR 20.2.7 Characteristics of fan (1) Cassetteria type (FDR) How to interpret the blower characteristics table ● External static pressure table Duct specs. 40(4) 45(4.5) 85(8.5) 45(4.5) 85(8.5) FDR45 56 type FDR71 type 14 - - 18 30(3) 65(6.5) 45(4.5) 80(8) 50(5) 85(8.5) FDR90 type 20 25(2.5) 60(6) 45(4.5) 80(8) 50(5) 85(8.5) FDR112 type 28 40(4) 70(7) 50(5) 80(8) 55(5.5) 85(8.5) FDR140 type 34 40(4) 70(7) 50(5) 80(8) 55(5.5) 85(8.5) Static pressure Pa (mmAq) 45(4.5) 85(8.5) 50(5) - 90(9) 50(5) 85(8.5) 50(5) 90(9) 20(2) 0(0) -20(-2) 2 Square duct blowout........... Internal resistance decreases more than the standard round duct (ø200 3-spot). 3Pa (0.3mmAq) at 17 m3/nin. (External static pressure increases in reverse.) ium ed - - M - 12 rd da an 10 FDR28 type w Lo FDR22 type St Stan- High(4) Stan- High(4) Stan- High(4) dard speed dard speed dard speed Type 1 2-spot blowout..................... Internal resistance increases more than the standard 3-spot blowout. Approx. 14Pa(1.4mmAq) at 17m3/min Example : Case of FDRJ71HKXE2 Square duct (3) rd da an h St Hig Standard (2) rd da an St Air flow (m3 /min) 1 spot (1) closing Unit : Pa (mmAq) 2-spot blower internal resistance [Standard] 3-spot blower internal resistance Square duct blower internal resistance 3 Suction panel....................... When the suction panel is not used with the ceiling return type, the part of internal resistance related to the panel decrease. 3Pa 20 (0.3mmAq) at 17mm3/min. Internal resistance without withoutsuction suctionpanel panel Internal resistance without filter 13 14 Notes (1) 1 spot closing: Round duct flange at center is removed and shield with a special panel (option). (2) Standard: Ø200 duct are installed at all blowout holes. (3) Square duct: All round ducts are removed and replaced with special square duct flanges (option). (4) When operating at a high speed, invert the connection of white and red connectors on the flank of control box. 16 18 Air flow (m3 /min) Model FDRJ28HKXE2 Model FDRJ22HKXE2 120(12) 100(10) Hi d ee sp it h Hig w lim Lo gh m 9 0(0) (0)0 [Standard] 2-spot blower internal resistance Square duct blower internal resistance Internal resistance without suction panel Internal resistance without filter 8 •Hi diu Me m (0)0 [Standard] 1-spot blower internal resistance Square duct blower internal resistance ard iu • ard nd h 20(2) nd ig •H Sta Static pressure Pa (mmAq) gh 40(4) ed ow •M •L 20(2) Hi rd rd rd da da an an S per Up Sta da St 60(6) ndard it lim ta w ium ed •Lo ed pe ard •M hs nd Hig w Sta Lo an 40(4) • ed ed pe h s it g i m H w li Lo d• pe gh ee d• sp ee gh Hi 80(8) sp St ard t nd limi Sta per Up gh hs 60(6) Hi Hig d ee sp imit h l g 80(8) Hi per H Up Hi M igh Lo gh e di sp w sp um ee ee d d St Static pressure Pa (mmAq) 100(10) d• ee sp it h im Hig per l Up 10 (-2)-20 Air flow (m3/min) (-2)-20 Internal resistance without filter 11 Upper limit Lower limit Internal resistance without suction panel 10 12 14 15.5 Upper limit Lower limit Air flow (m3/min) 1011 FDC-HKXR Models FDRJ45HKXE2, 56HKXE2 Model FDRJ71HKXE2 120(12) 120(12) d• pee h sr limit g i H pe Up Hi e sp it ed •M ed 60(6) lim r pe Up it ow gh S Hi ta ium rd• a nd gh gh Hi gh Hi s gh sp ar w •L an St rd gh Hi d• da ium ed •M rd da ow 2-spot blower internal resistance (0)0 [Standard] 2-spot blower internal resistance Square duct blower internal resistance [Standard] 3-spot blower internal resistance (-2)-20 12 14 Air flow (m /min) 13 14 Lower limit 18 20 Upper limit 120(12) 100(10) 100(10) gh ee sp igh gh sp ium ed M d ee gh sp ow li •L St • ed 60(6) rd• nda t Sta er limi p p Hi U g h Hi gh sp ee d• H sp ee igh d• M ed ee d Lo w it ium sp h Hig lim Hi gh ow um edi M rd• m diu Me • rd da an St gh •L rd da an Hi • rd nda w Lo 20(2) w •Lo ed St an da rd • spe 40(4) St da an Hi Sta • ard nd 20(2) t mi Static pressure Pa (mmAq) d• ee 40(4) 80(8) H d• Hi e sp gh Hi ow L • ard t nd limi a t r S pe Up d• ee sp mit h i l Hig per Up Hi gh Hi d• ee sp mit h i Hig per l Up Sta Static pressure Pa (mmAq) 16 Air flow (m3/min) Model FDRJ112HKXE2 120(12) 60(6) (-2)-20 Internal resistance without suction panel Internal resistance without filter 15.5 Upper limit 3 Model FDRJ90HKXE2 80(8) (0)0 Square duct blower internal resistance Internal resistance without suction panel Internal resistance without filter 10 Lower limit •L d an Hi Lo an gh w Lo 20(2) lim St gh d St •Hi ard 40(4) ee nd d ee sp Sta m diu Me rd• nda Sta • ard nd Sta Static pressure Pa (mmAq) Hi ium 40(4) e pe Hi lim d• ee sp d• ed •M ed h Hig gh ee p dU 80(8) it w •Lo ed e sp lim r pe Hi sp e sp • imit er l p •Up ard 60(6) Stand 20(2) it gh gh Hi rd da an St w Lo 80(8) 100(10) Static pressure Pa (mmAq) 100(10) 2-spot blower internal resistance (0)0 3-spot blower internal resistance 0(0) 4-spot blower internal resistance[Standard] 3 - spot blower internal resistance[Standard] Square duct blower internal resistance Square duct blower internal resistance (-2)-20 Internal resistance without suction panel Internal resistance without filter 14 Lower limit 1012 17 -2(-20) Internal resistance without suction panel Internal resistance without filter 20 Air flow (m3/min) 22 Upper limit 21 22 Lower limit 25 28 Air flow (m3/min) 31 Upper limit FDC-HKXR Model FDRJ140HKXE2 120(12) d ee sp m iu da an St w Lo d• ee sp d ee sp it h g m Hi w li Lo a St 40(4) h ig ed M d• gh 60(6) •H ee • rd t da limi n a r St ppe U Hi H rd• igh 20(2) •M rd w da Lo d• ar an St nd Static pressure Pa (mmAq) h ig H sp 80(8) gh Hi • ed pe it s m gh li Hi per p U 100(10) ium ed 3-spot blower internal resistance (0)0 (0)0 4-spot blower internal resistance [Standard] Square duct blower internal resistance Internal resistance without suction panel Internal resistance without filter 24 Lower limit 26 30 34 3 Air flow (m /min) (-2)-20 38 Upper limit 1013 FDC-HKXR (2) Satellite ducted type (FDUM) ● External static pressure table Duct specs. 1 spot closing Standard Square duct How to interpret the blower characteristics table Example : Case of FDUMJ71HKXE2 40(4) 90(9) 50(5) 90(9) 18 35(3.5) 70(7) 50(5) 85(8.5) 55(5.5) FDUM90 type 20 30(3) 65(6.5) 50(5) 85(8.5) 55(5.5) FDUM112 type 28 50(5) 80(8) 60(6) FDUM140 type 34 50(5) 75(7.5) 60(6) 90(9) 90(9) 90(9) 65(6.5) 95(9.5) 85(8.5) 65(6.5) 95(9.5) Note (1) For high speed operation, insert the white connector and the red connector beside the control box in other places respectively. Static pressure Pa (mmAq) 50(5) 85(8.5) rd da an um St edi M 85(8.5) 50(5) w 50(5) - Lo - - rd - 14 da 12 an FDUM36 type FDUM45 56 type FDUM71 type St Stan- High(4) Stan- High(4) Stan- High(1) dard speed dard speed dard speed Type rd da an gh St H i Air flow (m3 /min) Unit : Pa (mmAq) 20(2) 2-spot blower internal resistance 0(0) -10(-1) 3-spot blower internal resistance Square duct blower internal resistance -20(-2) 13 14 16 18 20 Air flow (m /min) 3 1 2-spot blowout..................... Internal resistance increases more than the standard 3-spot blowout. Approx. 14Pa(1.4mmAq) at 17m3/min 2 Square duct blowout........... Internal resistance decreases more than the standard round duct (ø200 3-spot). 3Pa(0.3mmAq) at 17 m3/min. (External static pressure increases in reverse.) Model FDUMJ36HKXE2 Models FDUMJ45HKXE2, 56HKXE2 120(12) er pp 100(10) U d• t imi l spe 100(10) igh •H Static pressure Pa (mmAq) gh ard nd Sta ard nd Static pressure Pa (mmAq) Hi ium • ium ed •M rd 20(2) Sta a nd Sta w Lo igh •H ard nd ium Sta ed •M ard nd Sta w Lo rd• d ee sp it h Hig w lim Lo 40(4) 0(0) Square duct blower internal resistance -10(-1) -20(-2) 1014 it lim d Me d• er p •Up 0(0) 2-spot blower internal resistance d• ee ard nd Sta ee sp 60(6) sp gh e sp ow lim d•L it w •Lo ed a nd Sta h Hig Hi ee 80(8) gh ium • ed ed •M pe ed hs Hig w Lo 20(2) sp Hi d• gh ee pe hs 40(4) Hi sp Hig • ard nd limit a t S per Up gh gh Hi 80(8) Hi • ed spe it h m Hig per li Up e h Hig 10 12 14 10 Lower limit Air flow (m3/min) Upper limit Lower limit 2-spot blower internal resistance [Standard] Square duct blower internal resistance 12 Air flow (m3/min) 14 15.5 Upper limit FDC-HKXR Model FDUMJ71HKXE2 Model FDUMJ90HKXE2 120(12) 120(12) 100(10) ee da an ow St L d• gh Hi rd• 40(4) Sta w ium Me rd• 20(2) ed 2-spot blower internal resistance nda •Lo ard •M rd nd da Sta Static pressure Pa (mmAq) d• ee p s it gh lim Hi w Lo sp Static pressure Pa (mmAq) m iu ed M d• ee sp U rd• da 60(6) Stan gh an diu 0(0) t mi r li e pp Hi St 20(2) gh Hi gh m iu w d• r da an St w Lo Lo d• ee sp 40(4) h ig •H Hi ed M d• gh Hi d ee sp it h ig lim H ow L d ee sp d• ee sp ee • rd da limit n a St per Up h ig H gh 80(8) sp 60(6) d• ee sp it h m Hig per li Up Hi gh Hi 80(8) 100(10) d ee sp mit h i l g Hi per Up (0)0 m [Standard] 3-spot blower internal resistance Square duct blower internal resistance (-1)-10 0(0) (-2)-20 2-spot blower internal resistance -10(-1) 3-spot blower internal resistance 13 14 Lower limit 16 18 Square duct blower internal resistance 20 Upper limit Air flow (m3/min) 14 Lower limit Model FDUMJ112HKXE2 120(12) 100(10) igh •M rd ed Static pressure Pa (mmAq) H d• r da an da Static pressure Pa (mmAq) St 40(4) rd ium 0(0) 3-spot blower internal resistance ium 20(2) ow •L rd da an ed d ee sp it h g m Hi w li Lo an St St rd •M da an St w Lo da um an ow St 40(4) 60(6) L d• igh ee ow d• H sp ar gh d• L Hi ee • ed spe it h Hig w lim S tan Lo d h ig ium i ed ed • rd da limit n a St per Up •M d• M H 80(8) ee d ee sp igh sp d• gh d•H ee sp ee h sp ig gh d ee sp imit h l g Hi per Up H Hi 100(10) Hi d• pee h s limit g i H er p Hi Up gh it r lim ppe U • rd Hi gh nda 60(6) Sta sp 20(2) 22 Upper limit Model FDUMJ140HKXE2 120(12) 80(8) 17 20 Air flow (m3/min) 3-spot blower internal resistance 0(0) 4-spot blower internal resistance[Standard] 4-spot blower internal resistance (-1)-10 (-1)-10 Square duct blower internal resistance Square duct blower internal resistance 24 21 Lower limit 25 28 Air flow (m3/min) 31 Upper limit Lower limit 26 30 34 Air flow (m3/min) 38 Upper limit 1015 FDC-HKXR 20.2.8 Noise level Notes (1) The data are based on the following conditions. Ambient air tempetature: Indoor unit 27˚C DB, 19˚C WB. Outdoor unit 35˚C DB (2) The data in the chart are measuted in an unechonic room. (3) The noise levels measured in the field are usually higher than the data because of reflection. (1) Indoor unit Measured based on JIS B 8616 Mike position as below Mike position as below (a) Ceiling recessed type (FDT) 1.5m Mike (center & low points) 60 60 N60 50 50 N50 40 40 N40 30 30 N2 N30 0 20 63 125 250 500 1000 2000 4000 20 8000 70 70 N70 60 60 N60 50 50 N50 40 40 N40 30 30 N2 N30 0 20 63 Mid octave band frequency (Hz) 125 250 500 1000 2000 20 8000 4000 60 N60 50 50 N50 40 40 N40 30 30 N2 N30 0 20 63 125 250 500 1000 2000 4000 20 8000 Sound pressure level (Standard 0.0002µ bar) dB Sound pressure level (Standard 0.0002µ bar) dB 70 N70 60 70 70 N70 60 60 N60 50 50 N50 40 40 N40 30 30 N2 70 63 60 N60 50 N50 40 40 N40 30 30 N2 N30 0 20 63 Mid octave band frequency (Hz) 125 250 500 1000 2000 20 8000 4000 250 500 1000 2000 20 8000 4000 Model FDTJ140HKXE2 Noise level 50 dB (A) at HIGH 47 dB (A) at MEDIUM 45 dB (A) at LOW 70 50 125 Mid octave band frequency (Hz) N70 60 N30 0 20 Mid octave band frequency (Hz) Model FDTJ90HKXE2 Model FDTJ112HKXE2 Noise level 42 dB (A) at HIGH Noise level 49 dB (A) at HIGH 40 dB (A) at MEDIUM 46 dB (A) at MEDIUM 38 dB (A) at LOW 42 dB (A) at LOW 70 Sound pressure level (Standard 0.0002µ bar) dB 70 N70 Model FDTJ71HKXE2 Noise level 40 dB (A) at HIGH 38 dB (A) at MEDIUM 36 dB (A) at LOW Sound pressure level (Standard 0.0002µ bar) dB 70 Sound pressure level (Standard 0.0002µ bar) dB Sound pressure level (Standard 0.0002µ bar) dB Models FDTJ28HKXE2, 36HKXE2 Models FDTJ45HKXE2, 56HKXE2 Noise level 37 dB (A) at HIGH Noise level 38 dB (A) at HIGH 34 dB (A) at MEDIUM 35 dB (A) at MEDIUM 33 dB (A) at LOW 34 dB (A) at LOW 70 70 N70 60 60 N60 50 50 N50 40 40 N40 30 30 N2 N30 0 20 63 Mid octave band frequency (Hz) 125 250 500 1000 2000 4000 20 8000 Mid octave band frequency (Hz) (b) 2-way outlet ceiling recessed type (FDTW) Models FDTWJ28HKXE2B, 45HKXE2B Model FDTWJ71HKXE2B 56HKXE2B Measured based on JIS B 8616 Noise level 39 dB (A) at HIGH Noise level 41 dB (A) at HIGH Mike position as below 36 dB (A) at MEDIUM 38 dB (A) at MEDIUM 33 dB (A) at LOW 35 dB (A) at LOW Mike position as below 70 70 70 Mike (center & low points) 60 60 N60 50 50 N50 40 40 N40 30 30 20 63 125 250 500 1000 2000 4000 Mid Octave Band Frequency (Hz) 1016 60 60 N60 50 50 N50 40 40 N40 30 30 N30 N2 0 70 N70 Souud Pressure Level (standard 0.0002µ bar) 1.5m Souud Pressure Level (standard 0.0002µ bar) N70 N30 N2 0 20 8000 20 63 125 250 500 1000 2000 4000 Mid Octave Band Frequency (Hz) 20 8000 FDC-HKXR Model FDTWJ90HKXE2B Model FDTWJ112HKXE2B Model FDTWJ140HKXE2B Noise level 41 dB (A) at HIGH Noise level 44 dB (A) at HIGH Noise level 45 dB (A) at HIGH 39 dB (A) at MEDIUM 41 dB (A) at MEDIUM 42 dB (A) at MEDIUM 36 dB (A) at LOW 38 dB (A) at LOW 39 dB (A) at LOW 70 70 70 60 N60 50 50 N50 40 40 N40 30 30 N2 125 250 0 500 60 60 50 50 N50 40 40 N40 30 30 1000 2000 4000 N2 20 8000 63 125 250 500 60 60 N60 50 50 N50 40 40 N40 30 30 N30 0 20 1000 2000 4000 N2 20 8000 N30 0 20 63 Mid Octave Band Frequency (Hz) Mid Octave Band Frequency (Hz) 70 N70 N60 N30 20 63 Souud Pressure Level (standard 0.0002µ bar) Souud Pressure Level (standard 0.0002µ bar) 60 70 N70 N70 Souud Pressure Level (standard 0.0002µ bar) 70 125 250 500 1000 2000 4000 20 8000 Mid Octave Band Frequency (Hz) (c) 1-way outlet ceiling recessed type (FDTS) Measured based on JIS B 8616 Mike position as below 1.5m Mike (center & low points) 70 N70 60 60 N60 50 50 N50 40 40 N40 30 30 N2 N30 0 20 63 125 250 500 1000 2000 4000 20 8000 Mid octave band frequency (Hz) Model FDTSJ45HKXE2B Noise level 43 dB (A) at HIGH 40 dB (A) at MEDIUM 38 dB (A) at LOW Sound pressure level (Standard 0.0002 µ bar) dB 70 Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002µ bar) dB Model FDTSJ22HKXE2B Models FDTSJ28HKXE2B, 36HKXE2B Noise level 39 dB (A) at MEDIUM Noise level 40 dB (A) at HIGH 38 dB (A) at LOW 39 dB (A) at MEDIUM 38 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Model FDTSJ71HKXE2B Noise level 44 dB (A) at HIGH 40 dB (A) at MEDIUM 38 dB (A) at LOW Mid octave band frequency (Hz) 1017 FDC-HKXR (d) Cassetteria type (FDR) Unit 1.5m Measured based on JIS B 8616 Mike position as below Mike (center & low points) Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Model FDRJ28HKXE2 Models FDRJ45HKXE2, 56HKXE2 Noise level 43 dB (A) at HIGH Noise level 44 dB (A) at HIGH 41 dB (A) at MEDIUM 41 dB (A) at MEDIUM 38 dB (A) at LOW 38 dB (A) at LOW Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB (i) Canvas duct Panel type Model FDRJ22HKXE2 Noise level 42 dB (A) at HIGH 40 dB (A) at MEDIUM 37 dB (A) at LOW 1.5m Mid octave band frequency (Hz) Mid octave band frequency (Hz) Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Models FDRJ71HKXE2, 90HKXE2 Model FDRJ112HKXE2 Model FDRJ140HKXE2 Noise level 44 dB (A) at HIGH Noise level 46 dB (A) at HIGH Noise level 47 dB (A) at HIGH 41 dB (A) at MEDIUM 43 dB (A) at MEDIUM 44 dB (A) at MEDIUM 38 dB (A) at LOW 39 dB (A) at LOW 40 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) Mid octave band frequency (Hz) 1018 Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB (ii) Silent Panel type Model FDRJ22HKXE2 Model FDRJ28HKXE2 Models FDRJ45HKXE2, 56HKXE2 Noise level 43 dB (A) at HIGH Noise level 42 dB (A) at HIGH Noise level 41 dB (A) at HIGH 39 dB (A) at MEDIUM 40 dB (A) at MEDIUM 40 dB (A) at MEDIUM 37 dB (A) at LOW 37 dB (A) at LOW 36 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) FDC-HKXR Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Models FDRJ71HKXE2, 90HKXE2 Model FDRJ112HKXE2 Model FDRJ140HKXE2 Noise level 43 dB (A) at HIGH Noise level 45 dB (A) at HIGH Noise level 46 dB (A) at HIGH 40 dB (A) at MEDIUM 42 dB (A) at MEDIUM 43 dB (A) at MEDIUM 37 dB (A) at LOW 38 dB (A) at LOW 39 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) (d) Satellite ducted type (FDUM) Measured based on JIS B 8616 Mike position as below Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Noise level 34 dB (A) at HIGH 32 dB (A) at MEDIUM 29 dB (A) at LOW Models FDUMJ45HKXE2, 56HKXE2 Model FDUMJ90HKXE2 71HKXE2 Noise level 36 dB (A) at HIGH Noise level 35 dB (A) at HIGH 32 dB (A) at MEDIUM 33 dB (A) at MEDIUM 30 dB (A) at LOW 29 dB (A) at LOW Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Model FDUMJ36HKXE2 1.5m Mid octave band frequency (Hz) Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Model FDUMJ112HKXE2 Model FDUMJ140HKXE2 Noise level 38 dB (A) at HIGH Noise level 39 dB (A) at HIGH 35 dB (A) at MEDIUM 37 dB (A) at MEDIUM 32 dB (A) at LOW 34 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) 1019 FDC-HKXR 1m (f) Ceiling suspension type (FDE) Unit 1m Measured based on JIS B 8616 Mike position as below Noise level 44 dB (A) at HIGH 40 dB (A) at MEDIUM 38 dB (A) at LOW Mid octave band frequency (Hz) Model FDEJ112HKXE2B Noise level 49 dB (A) at HIGH 46 dB (A) at MEDIUM 42 dB (A) at LOW Sound pressure level (Standard 0.0002 µ bar) dB Model FDEJ71HKXE2B Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Models FDEJ36HKXE2B, 45HKXE2B 56HKXE2B Noise level 43 dB (A) at HIGH 40 dB (A) at MEDIUM 38 dB (A) at LOW Mike (front & low point) Mid octave band frequency (Hz) Mid octave band frequency (Hz) Sound pressure level (Standard 0.0002 µ bar) dB Model FDEJ140HKXE2B Noise level 50 dB (A) at HIGH 47 dB (A) at MEDIUM 42 dB (A) at LOW Mid octave band frequency (Hz) (g) Wall mounted type (FDK) Measured based on JIS B 8616 Mike position as below 50 N50 40 40 N40 30 30 N30 N2 0 20 63 125 250 500 1000 2000 4000 20 8000 Mid octave band frequency (Hz) 1020 Model FDKJ45HKXE2 Noise level 44 dB (A) at HIGH 41 dB (A) at MEDIUM 37 dB (A) at LOW Sound pressure level (Standard 0.0002 µ bar) dB 60 N60 50 Mike (Center & low points) Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002µ bar) dB 70 N70 60 1m Models FDKJ28HKXE2, 36HKXE2 Noise level 42 dB (A) at HIGH 40 dB (A) at MEDIUM 37 dB (A) at LOW Model FDKJ22HKXE2 Noise level 40 dB (A) at HIGH 37 dB (A) at LOW 70 1m Unit Mid octave band frequency (Hz) Mid octave band frequency (Hz) FDC-HKXR Model FDKJ56HKXE2 Noise level 46 dB (A) at HIGH 43 dB (A) at MEDIUM 39 dB (A) at LOW Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Model FDKJ71HKXE2 Noise level 47 dB (A) at HIGH 44 dB (A) at MEDIUM 40 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) (h) Floor standing exposed type (FDFL) (i) Floor standing hidden type (FDFU) Measured based on JIS B 8616 Mike position as below Indoor unit Mike (front & at low point) 1m 1m Models FDFLJ 45HKXE2,71HKXE2 FDFUJ45HKXE2, 56HKXE2 71HKXE2 Noise level 43 dB (A) at HIGH 41 dB (A) at MEDIUM 40 dB (A) at LOW Sound pressure level (Standard 0.0002 µ bar) dB Sound pressure level (Standard 0.0002 µ bar) dB Models FDFLJ28HKXE2 FDFUJ28HKXE2 Noise level 41 dB (A) at HIGH 38 dB (A) at MEDIUM 36 dB (A) at LOW Mid octave band frequency (Hz) Mid octave band frequency (Hz) (2) Outdoor unit (FDC) Microphone position of noise meter ˚ Elevation 45 Note (1) The microphone position is as shown below. (JIS - B8616 · Coolong) It is the maximum noise level point which locates on the vertical face 1 m apart from unit side face. 1m 1m Sound pressure level (Standard 0.0002 µ bar) dB Models FDCP2001HKXRE2, 2501HKXRE2 Noise level 60 dB (A) 70 70 60 60 50 50 40 40 30 30 63 125 250 500 1000 2000 4000 20 8000 Mid octave band frequency (Hz) 1021 B TB A N BL BL WH RD Y/GN Fan motor Internal thermostat for FMI Capacitor for FMI Drain motor Float switch (For overflow prevention) Louver motor Limit switch Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For DM) Auxiliary relay (For LM) ThI-A ThI-R SW1 SW2 SW3 SW4 SW6 Trl Val LED·R LED·G 1 2 X2 Thermistor Thermistor Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Parts name WH M 12 X3 3 CnD 10 OR H 4 1 2 X4 CnR 9 1 2 CnI FS CnI WH J5 J6 J2 X5 X4 X3 X2 X1 J7 J3 X6 220/240V CnW1 Parts name Val Fuse Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Spark killer CnR DM F CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 SK Mark CFI SK CnF 11 CnF FMI (49FI) 2 L 13 X6 1 Y/GN 5 Y/GN Printed circuit board CnJ LM CnJ 3 X5 X1 WH J4 SW5 SW6 1 2 3 CnB CnS CnN CnH CnT CnA GR Mark SW5-3 SW5-2 SW5-1 Color Red White Yellow Yellow/Green Mark Test run of condensate pump motor Normal OFF Normal ON OFF Run Stop Reverse Invalid Heating temp. shift + 3°C Input signal Function Remote controller RD WH BK Thc RD WH Y Y/GN Thl-R SM ON OFF ON Option Thl-A X Y Z BK BK BK LS XR4 BK Color Y Z X BK BK CnS2 XR5 Black Blue Brown Gray Orange BK WH RD BK BK BK GR XR2 RD Y BK XR3 OR RD Y XR1 CnA2 OR Function of switches BK BL BR GR OR Mark Color mark ON OFF 1 2 3 4 ON OFF SW4 Check SW1 SW2 SW3 Normal LED·G LED·R HA CnZ CnW2 BL BL RD Checker 17V 8V RD CnE Trl Models All models Mark CnO CnK2 2 1 (a) Ceiling recessed type (FDT) FMI 49FI CFI DM FS LM LS SM X1,2,3,6 X4 X5 Y/GN CnK WH RD (1) Indoor unit Mark Parts name F(3.15A)RD 20.3.1 Electrical wiring Meaning of marks Outdoor unit (Signal line) Power source TB L WH RD OR OR WH WH BL RD BK BK BK RD BL WH WH OR BR BR BK BK WH WH GR RD RD 1022 WH CnU FDC-HKXR 20.3 ELECTRICAL DATA FMI 49FI CFI DM FS LM LS SM X1,2,3,6 X4 X5 Mark BL BL Parts name B A TB Y/GN WH RD F(3.15A) Fan motor Internal thermostat for FMI Capacitor for FMI Drain motor Float switch (For overflow prevention) Louver motor Limit switch Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For DM) Auxiliary relay (For LM) Meaning of marks Outdoor unit (Signal line) N L TB Y/GN Y/GN ThI-A ThI-R SW1 SW2 SW3 SW4 SW6 Trl Val LED·R LED·G Mark Note (1) RD 2 1 CnF2 UH OR M OR CnF2 L WH CFI2 CnFC2 OR FMl2 H Printed circuit board 1 UH 12 11 13 CnF1 L X2 10 CnI1 CnFC1 OR OR CnF1 OR M 14 X6 WH FMl1 H X3 X1 Thermistor Thermistor Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Parts name F CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 SK Mark 4 CnD CnR Parts name CnI SK CnR FS DM CnI 9 X4 Fuse Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Spark killer 1. FMI2 is equipped with only for 112,140. CnO CnK2 BL CnK BL WH RD BK Power source RD RD WH WH BL WH WH GR RD RD WH WH BR BR RD RD WH WH 3 Val CnJ LM CnJ X5 OR OR WH WH CnU J6 J2 LED·G J7 J3 SW1 J8 J4 SW4 ON OFF 1 2 3 4 SW6 SW5 SW3 Check LED·R HA Mark CnB CnS CnN CnH CnT Mark SW5-3 SW5-2 SW5-1 BK WH RD RD WH Y Y/GN Mark Remote controller WH Thc Test run of condensate pump motor Normal ON Normal Color Red White Yellow Yellow/Green Option Reverse Invalid Run Stop Heating temp. shift + 3°C Input signal LS Z Y X BK Function Z Y X TB BK BK Thl-R Thl-A XR4 XR2 SM OFF OFF ON OFF ON BK RD XR5 XR3 XR1 28~56H CASES CnS2 BK BK BK BK BK BK GR BK GR WH OR RD Y WH CnA2 OR RD Y Function of switches Color Black Blue Brown Gray Orange Color mark BK BL BR GR OR CnA Checker CnW2 BL BL RD RD ON OFF 1 2 3 4 SW2 8V 17V CNZ CnE Normal X6 Trl J6 has 71H ~ 90H only shorted. J5 J1 X5 X4 X3 X2 X1 CnW1 WH 220/240V WH FDC-HKXR (b) 2-way outlet ceiling recessed type (FDTW) Models All models 1023 *1 FMI1,2 49FI CFI1,2 DM FS LM LS SM X1,2,3 X4 X5 RD L H RD CnF2 OR Y/GN WH CnW4 RD 8V CnM CnB2 RD CnK2 BL CnK BL CnW3 BL BL RD CnW2 CnO Y/GN BL BL CnW4 BL 17V BL RD RD WH WH RD RD Trl WH WH 220/240V RD CnL RD 2 1 *1 Val RD L H OR X1 CnF3 X2 CnD CFl2 UH BR OR CnF3 FMl2 (49FI) M Parts name ThI-A ThI-R SW1 SW2 SW3 SW4 SW6 Trl Val LED·R LED·G Mark Thermistor Thermistor Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Parts name (2) *1 FMI2 is equipped with only for FDTSJ71HKXE2B. CFI1 UH BR OR CnF2 FMI1 (49FI) M Fan motor Internal thermostat for FMI Capacitor for FMI Drain motor Float switch Louver motor Limit switch Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For DM) Auxiliary relay (For LM) Meaning of marks Mark BL Y/GN F(3.15A) BR RD L 8 6 CnF2 CFI1 UH BR OR OR *2 X3 CnF2 Cn Cn F6 F5 H FMl1 (49FI) M 7 X3 X2 X1 CnI FS SK CnI 9 X5 X4 F CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 SK Mark Fuse Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Spark killer Parts name Notes (1) FDTSJ22HKXE2B is different from others as indicated with *2 in the diagram below. B BL RD RD BL BL BL BK BK Outdoor unit (Signal line) TB A N Y/GN RD Y/GN Y/GN WH WH Power source L TB BL BL RD RD RD RD Y/GN BK BK BL BL BL WH WH WH WH WH Y/GN Y/GN BK BR BR BK BK BK GR RD RD WH BR BR X4 5 WH CnR SK CnR 4 DM RD RD WH WH WH OR OR X5 CnJS 3 CnJS LM OR WH 1024 WH CnU HA CNZ J5 J1 J6 J2 J7 J3 SW6 J4 ON 1 2 3 4 OFF SW5 SW3 SW4 ON 1 2 3 OFF SW2 BK RD WH Mark SW5-3 SW5-2 SW5-1 Color Red White Yellow Yellow/Green Test run of condensate pump motor Normal OFF Normal ON OFF Run Stop Reverse Invalid Heating temp. shift + 3°C Input signal ON OFF ON Mark Remote controller RD WH BK Thc X Y Z Option SM RD WH Y Y/GN Y Z X TB LS Thl-R Thl-A XR4 XR2 Function CnB2 BK RD WH BK BK BL BK RD BL CnJS CnN2 BK BK CnH2 BK XR5 BL BK BK XR3 XR1 OR RD Y BK GR CnA2 Color Black Blue Brown Gray Orange CnB CnS CnN CnH CnT OR RD Y BK GR Function of switches BK BL BR GR OR Mark Color mark SW1 Normal Check LED·G LED·R Checker CnE CnA Printed circuit board FDC-HKXR (c) 1-way outlet ceiling recessed type (FDTS) Models All models BL BL WH Y/GN CnS Y/GN CnO CnK2 BL CnK BL WH RD 2 X1 CnF4 X2 Val 8 L Printed circuit board 1 OR OR WH Y/GN CnD CFl1 UH CnF4 CnF2 H 6 CnF4 FMI1 (49FI) M 7 X3 L BL X3 X2 X1 CnF2 CnF5 H OR OR CnF5 FMI2 (49FI) M BK X4 Parts name Fan motor Capacitor for FMI Drain motor Float switch Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For DM) Internal thermostat for FMI Thermistor Thermistor Mark FMI1,2 CFI1,2 DM FS SM X1,2,3 X4 49FI ThI-A ThI-R SW1 SW2 SW3 SW4 SW6 Trl Val LED·R LED·G F Mark Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Fuse Parts name CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 SK Mark 5 4 CnRI CnI FS CnI CnRI Parts name CnRI CnR DM SK CnR CnRI 9 X4 Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Spark killer CnF3 CFI2 UH CnF5 *1 CnF3 Note (1) *1 FMI2 is equipped with only for FDRJ112HKXE2,140HKXE2. B A TB N Meaning of marks Outdoor unit (Signal line) Power source F(3.15A) BK RD Y/GN Y/GN BL TB L BL RD RD BL BL BK BK BK RD RD BR BR WH WH RD RD BL Y/GN Y/GN BL RD WH WH BL BK BK BK BR BR BR WH BR BR BK RD RD BK WH WH WH GR RD RD RD RD WH RD SW6 1 2 3 SW5 J5 J3 J6 J4 OR RD Y BK GR Y X BK Color Black Blue Brown Gray Orange Remote controller RD WH BK Thc X Y Z CnA2 TB BK Mark SW5-3 SW5-2 SW5-1 Test run of condensate pump motor Normal OFF Normal ON OFF Run Stop Reverse Invalid Color Red White Yellow Yellow/Green Heating temp. shift + 3°C Input signal Function Mark RD WH Y Y/GN SM ThI-R ON OFF ON Option ThI-A XR4 XR2 Function of switches Mark BK BL BR GR OR BK BK CnN3 BK BK CnN2 Z XR3 XR1 XR5 CnH2 CnB BK WH RD OR RD Y BK GR RD RD BK BK Color mark J7 ON 1 2 3 4 OFF ON OFF CnN SW3 SW4 Check Normal SW2 LED·R LED·G SW1 HA CnZ CnH CnW2 BL 17V BL RD 8V Checker TrI CnE CnW1 WH 200/240V WH CnT CnA CnU FDC-HKXR (d) Cassetteria type (FDR) Models All models 1025 Mark Parts name Fan motor Capacitor for FMI Drain motor Float switch (For overflow prevention) Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For DM) Internal thermostat for FMI Thermistor Thermistor Meaning of marks FMI1,2 CFI1,2 DM FS SM X1,2,3 X4 49FI ThI-A ThI-R Y/GN BL CnM CnO CnK2 BL CnK BL B N TB A BL RD WH Y/GN F(3.15A) WH TB L RD 2 1 X1 CnF4 X2 Val L 8 BL H Y/GN WH CnF4 OR OR CFI1 UH Mark SW1 SW2 SW3 SW4 SW6 Trl Val LED R LED G F Parts name Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Fuse X1 X2 L BL M BK CnF2 Mark CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 SK X3 H X4 OR OR CnF5 FMI2 (49FI) CnF5 CnD CnF4 CnF2 6 FMI1 (49FI) M 7 X3 Printed circuit board RD Note (1) 1 FMI2 is equipped with only for FDUMJ112HKXE2, 140HKXE2. Outdoor unit (Signal line) Power source BL RD WH BK BK BK BR BR BK RD RD RD Y/GN Y/GN WH RD RD BL BL BL Y/GN WH WH WH Y/GN BL BL BK BK BK BR BR BR CnF3 CFI2 UH CnF5 *1 CnF3 4 SK Parts name 5 CnG CnRI CnR DM CnR CnRI X4 9 Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Spark killer WH BR BR BK RD RD BK WH WH WH GR RD RD RD RD 1026 WH CnU CnRI CnI FS CnI CnRI Check Normal J5 J3 J6 J4 SW6 ON OFF 1 2 3 4 SW5 ON OFF 1 2 3 CnN CnA BK Z Y CnB BK X TB WH RD OR RD Y BK GR Mark BK BK OR RD Y BK GR Black Blue Brown Gray Orange Color Remote controller RD WH BK Thc X Y Z CnA3 OR RD Y BK GR SW5-3 SW5-2 SW5-1 Mark Color Red White Yellow Yellow/Green Mark RD WH Y Y/GN Test run of condensate pump motor Normal OFF Normal ON OFF Run Stop Reverse Invalid Heating temp. shift + 3 Input signal Function SM Thl-R Thl-A Option ON OFF ON Function of switches BK BL BR GR OR BK BK BK BK CnH2 CnN2 CnN3 RD/BK RD/BK CnA2 RD RD BK XR1 XR2 XR3 XR4 XR5 Color mark J7 CnT CnH SW1 SW2 SW3 SW4 LED·R HA LED·G CnZ Checker CnE BL 17V 8V RD CnW2 Trl CnW1 WH 220/240V WH FDC-HKXR (e) Satellite ducted type (FDUM) Models All models B A TB Mark FMI1,2 CFI1,2 49FI LM LS SM X1,2,3 X5 ThI-A ThI-R WH RD WH Y/GN RD BL BL CnM BL BL RD RD CnO CnK2 BL CnK BL CnW3 Y/GN CnK2 CnW4 BL 17V BL CnW2 RD WH RD 2 1 VaI *1 L X3 X2 X1 OR OR H60 CnF3 FMI2 (49FI) M X5 X4 BR Y/GN CnD CFI2 H50 CnF3 X2 X1 L 8 H 6 OR OR CnF2 FMI1 (49FI) M Cn F6 7 X3 CFI1 UH CnF2 Cn F5 Fan motor Capacitor for FMI Internal thermostat for FMI Louver motor Limit switch Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For LM) Thermistor Thermistor SW1 SW2 SW3 SW4 SW6 Trl Val LED·R LED·G F Mark Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Fuse Parts name CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 SK Mark Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Spark killer Parts name Note (1) *1 FMI2 is equipped with only for FDEJ71HKXE2B,112HKXE2B,140HKXE2B. Parts name BL BL CnW4 WH 200/240V 8V RD WH CnL Tr1 RD RD Y/GN RD WH Meaning of marks Outdoor unit (Signal line) N F(3.15A) RD RD BL L BK TB RD RD Power source BK BK WH WH RD Y/GN Y/ GN WH WH BL BL BK BR BR SK OR OR X5 CnJS 3 5 CnJS LM OR WH WH WH WH RD J5 J1 Mark J4 Color Black Blue Brown Gray Orange J7 J3 Mark SW5-3 SW5-2 SW5-1 Mark CnB2 BK RD WH Y Y/GN BK WH RD RD WH BK BL Test run of condensate pump motor Normal OFF Normal Remote controller ON OFF Run Stop X Y Z RD WH BK Thc Color Red White Yellow Yellow/Green Reverse Invalid Z Y X TB SM LS ThI-R ThI-A XR4 XR2 Heating temp. shift + 3°C Input signal BK BK CnN2 BK CnH2 BK XR5 XR3 XR1 GR CnS CnS2 BL RD RD BK BK GR ON OFF ON Y Y BK RD BK OR RD OR Function CnB CnN CnH CnT Function of switches BK BL BR GR OR J6 J2 SW6 ON OFF 1 2 3 4 ON OFF 1 2 3 SW5 SW1 SW2 SW3 SW4 Normal Check LED·G LED·R HA CnZ Color mark 9 Checker CnE CnA Printed circuit board Option CnU FDC-HKXR (f) Ceiling suspension type (FDE) Models All models 1027 FMI CFI 49FI LM LS SM X1,2,3 X5 ThI-A ThI-R Y/GN BL BL Y/GN CnF1 Parts name H WH OR OR CnF1 CnF2 M BL BL FMI1 (49FI) L BK BK *1 RD RD Y/GN WH WH Fan motor Capacitor for FMI Internal thermostat for FMI Louver motor Limit switch Stepping motor (For Exp.v) Auxiliary relay (For FMI) Auxiliary relay (For LM) Thermistor Thermistor Meaning of marks Mark B TB A WH F(3.15A) Y/GN CnO CnK2 BL CnK BL WH RD VaI CnF1 Y/GN X2 X1 Printed circuit board 2 1 7 OR OR 5 H OR OR CnF1 6 CnF2 M CnF1 FMI (49FI) L 8 X3 CFI X3 X2 X1 CnD X5 GR 9 LM CnJ CnJ 3 X5 CFI SW1 SW2 SW3 SW4 SW6 Trl Val LED·R LED·G F Mark Indoor unit address ten's place Indoor unit address unit's place Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Fuse Parts name CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 Mark Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation Parts name Note (1) FDKJ22HKXE2 is different from others as indicated with *1 in the diagram below. Outdoor unit (Signal line) N RD RD RD Power source WH BL BL TB L BK BK RD WH WH WH OR OR WH WH 1028 J5 Normal Check LED·R HA CnZ LED·G J3 J6 J4 J7 SW6 1 2 3 4 CnB CnN CnH CnT OR Z Y Mark SW5-3 SW5-2 SW5-1 Color Red White Yellow Yellow/Green Test run of condensate pump motor Normal OFF Normal ON OFF Run Stop Reverse Invalid Heating temp. shift + 3°C Input signal ON OFF ON Mark RD WH Y Y/GN Function Remote controller RD WH BK Thc Color Black Blue Gray Orange BK WH SM LS ThI-R ThI-A XR4 XR2 X Y Z BK BL TB RD X BK CnS2 BL BK CnN2 BK XR5 XR3 XR1 CnS RD RD BK BK GR BK Y RD Function of switches BK BL GR OR Mark Color mark ON OFF ON 1 2 3 OFF SW5 CnA CnW2 BL BL RD RD Checker 17V 8V CnE TrI SW1 SW2 SW3 SW4 CnW1 WH 220/ 240V WH Option CnU FDC-HKXR (g) Wall mounted type (FDK) Models All models Parts name Fan motor Capacitor for FMI Internal thermostat for FMI Stepping motor (For Exp.v) Auxiliary relay (For FMI) Thermistor Thermistor Indoor unit address ten's place Indoor unit address unit's place Mark FMI CFI 49FI SM X1,2,3 ThI-A ThI-R SW1 SW2 B TB A BL BL Y/GN WH SW3 SW4 SW6 Trl Val LED·R LED·G F Mark Y/GN Val Parts name 2 1 X1 CnS X2 Y/GN Outdoor unit address ten's place Outdoor unit address unit's place Change of heat pume type Transformer Varistor Indication lamp (Red) Indication lamp (Green) Fuse CnK2 BL CnK BL WH RD Y/GN L 8 WH BK BK CnF H 6 CnA-Z TB mark mark XR1 XR2 XR3 XR4 XR5 Mark CnD CnF FMI (49FI) M 7 X3 5 9 Parts name J5 Connector ( mark) Terminal block Terminal (F) Connector Operation indication (DC12) Heating indication (DC12) ON indication for CM (DC12) Check indication (DC12) Distant operation WH CFI X3 X2 X1 Trl J3 J6 J4 J7 SW6 1 2 3 4 SW5 1 2 3 CnB CnN CnH CnT CnA Mark RD RD BK BK Black Blue Gray Orange XR4 Z Y X TB Mark SW5-3 SW5-2 SW5-1 X Y Z Color Red White Yellow Yellow/Green Mark RD WH Y Y/GN Remote controller RD WH BK Thc Test run of condensate pump motor Normal OFF Normal ON OFF Run Stop Reverse Invalid Heating temp. shift + 3°C Input signal ON OFF ON SM Function Thl-R Thl-A Color BK WH RD BK CnN BK BK CnH2 BK XR5 XR3 XR2 GR XR1 Y BK GR BK Function of switches BK BL GR OR OR Y RD CnA2 RD OR Color mark Printed circuit board ON OFF ON OFF SW1 SW2 SW3 SW4 Check Normal HA Checker CnW2 17V 8V LED·R BL BL RD RD LED·G CnZ CnE CnW1 WH 220/ 240V WH Models All models Meaning of marks Outdoor unit (Signal line) N RD RD/Y RD Power source F (3.15) BL BL BL RD RD BK BK BK TB L GR WH WH Option RD FDC-HKXR (h) Floor standing exposed type (FDFL) (i) Floor standing hidden type (FDFU) 1029 FDC-HKXR (2) Individual flow divide controller Power source (between indoor unit) Power source 1 phase 220/240V 50Hz Notes (1) This illustration shows the circuit diagram for when 1 indoor unit is connected with a central flow divide controller and relay kit (flow divide controller accessory). (2) “.......” denotes the local wiring. (3) The option shows when a remote start/stop and monitoring kit is connected. • Meaning of marks SVH High-pressure gas solenoid valve SVC Low-pressure gas solenoid valve SVL Liquid solenoid valve SVG Bypass solenoid valve XR, X1, XR1 Operation output XH, X2, XR2 Heat output 1030 XR3 Thermal ON output XR4 Inspection output CM FM1,2 IM 52C 49F1,2 CH CF1,2 X1 X2 X3 X4 X7 X8~10 X11 X12 X13 X14 X20 20SS Mark Parts name Compressor motor Fan motor (outdoor unit) Motor for cooling inverter Magnetic contactor for CM Internal thermostat for FMo Crankcase heater Capacitor for FMo Auxiliary relay (for 52C) Auxiliary relay (for 20SS) Auxiliary relay (for 20SL) Auxiliary relay (for SV1) Auxiliary relay (for 20VF, 20VU) Auxiliary relay (for FMo1) Auxiliary relay (for FMo2) Auxiliary relay (for SVS) Auxiliary relay (for SVL) Auxiliary relay (for SV2) Auxiliary relay (for SV3) 4way valve (front heat exchanger) Meaning of marks Notes (1) “.......” denotes the local wiring. (2) and of TB2 are the signal wire terminal blocks (5V). 20SL 20VF 20VU SV1 SV2 SV3 SVS SVL 63H1 63H2 63H3 63H4 63L Tho-A Tho-C Tho-D Tho-R CT1,2 NR Mark 4way valve (rear heat exchanger) Solenoid valve (full) Solenoid valve (partial) Solenoid valve (compressor cooling) Solenoid valve (excessive cooling heat exchanger by-pass) Solenoid valve (discharge gas by-pass) Solenoid valve (for front heat exchanger stoppage) SOlenoid valve (rear heat exchanger stoppage) High Pressure switch (for protection) High Pressure switch (for control) High Pressure switch (high pressure control) High Pressure switch (high pressure control) Low Pressure switch (low pressure control) Thermistor (outdoor air temp) Thermistor (dome temp) Thermistor (discharge temp) Thermistor (outdoor H.X. temp) Current sensor Noise killer Parts name SK SA Tr Va1,2,3,4 TB1,2 F CnA~Y SW1 SW2 SW3-1 SW3-2 SW3-3 LED1 LED2 LED3-5 LD1 LD2-4 Mark Parts name Spark killer Arrestor Transformer Varistor Terminal block Fuse Connector ( mark) Unit No.10 rank of outdoor unit Unit No.1 rank of outdoor unit L.E.D. reset Defrost change Prevention of snow accumulation Indication lamp (red) Indication lamp (Green) Indication lamp (Yellow) Indication lamp (Green) Indication lamp (red) (3) Use 0.75 to 2mm2 × 2 core wire for the indoor and outdoor connection signal wire. (4) The signal wiring shall be separate from the powe supply wiring. Power source 3 Phase 380/415V 50Hz (415/200V, 380/200V) Color Black Blue Brown Green Gray SW3-7 SW3-6 SW3-5 SW3-4 Mark Test mode Regular operation OFF Regular operation ON Compulsory operation OFF Heating trial operation ON Cooling trial operation OFF Regular operation OFF ON Trial operation Function Color Orange Red White Yellow Yellow/green Mark OR RD WH Y Y/GN ON Function of switches BK BL BR GN GR Mark Color mark FDC-HKXR (3) Outdoor unit Models FDCP2001HKXRE2, 2501HKXRE2 1031 FDC-HKXR 20.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER (1) Remote controller (Optional parts) FDR,FDUM,FDFL and FDFU series are not provided with AUTO SWING switch. Panel shown below will appear if you open the cover. All contents of display on the LCD are indicated simultaneously for the purpose of explanation. Pull the knob on the cover to this side to open it downward. Filter sign Operation mode display When this sign is indicated, clean the filter. Displays the operation mode that has been selected. Remote display Heating preparation display This is displayed when the unit is controlled with an individual controller during normal operation. (Also displayed when the air conditioner is stopped.) Operation/ Inspection indicator lamp During operation: Green lamp flashes. In case of error: Red lamp flashes. Central display This is displayed when the unit is controlled with the optional central console. On/Off switch Timer operation display Contents of timer operation are displayed. (Also displayed when the air conditioner is stopped.) CENTER REMOTE F I L T E R AUTODRYCOOLFANHOT PROGRAM TIMER FILTER AUTO LIFT ON Setting temperature display SET TEMP Outdoor No. Return air temperature display Displays the temperature that has been set. FILTER RESET TIMER CHECK SET TEMP T I M E Fan speed display Displays the fan speed that has been set. FAN Hi Mi Lo OFF A M P M KEEP Use this switch to start or stop the air conditioner. First push on the switch starts the unit and second push stops it. (The switch can be operated without opening the cover.) Filter reset switch Use this switch to reset (erase) the filter sign display. (Press the switch after cleaning the air filter.) F A N SPEED AUTO SWING Displays the return air temperature. MODE Note Indicated value may be different from actual reading on a thermometer or other instrument but this is notnecessarily an error. Auto swing display Indicates the swing louver condition. Mode switch Cover Inspection switch Use this switch when servicing the unit. Timer switch Use this switch to select operation modes. Fan speed switch Use this switch to set a fan speed. Auto swing switch Use this switch when selecting contents of timer operation. Use this switch to operate or stop the swing louver. Set switch Temperature/ Time setting switch Use this switch to set a time for the timer. Use this switch to set the room temperature or time on the timer. 1032 FDC-HKXR (2) Automatic Operation Once the [Auto] mode is selected by remote control, the operating mode is automatically selected according to the setting temperature and the intake air temperature of the indoor unit and cooling or heating operation is performed. The determination is performed when the thermostat has been in the OFF mode for 10 minutes or more continuously. Notes (1) No determination is made if the mode setting is cooling, dehumidify or heating and the cooling and heating thermostats have been in the off mode for 10 minutes in the automatic operation mode. (2) If set to automatic operation mode when the intake temperature is within ± 2 ˚C in relation to the setting temperature, the same operation as the previous automatic +2 operation will be performed. (Note that it will be the heating mode when first Room temperature setting turned on after the power has been turned off.) Cooling operation Heating operation -2 Room temperature (detected atThI-A) (deg.) (3) Operations of major functional items under each operation mode Operation mode Cooling Heating fan Dehumidify Functional item Thermostat ON Thermostat OFF Thermostat ON Thermostat OFF Defrost Indoor unit fan Remote controller Remote controller Remote controller Remote controller Intermittent operation command command command command → / Indoor unit electronic expansion valve According to determined frequency Fully closed Fully closed Fully open According to determined frequency / Compressor According to determined frequency Fully closed Outdoor unit fan → / Drain motor Solenoid valve (20VU) / / / Solenoid valve (20 VF) / / / Four-way valve (20 SL,S) Individual definitions Solenoid valve (SV1, L,S) Individual definitions Notes(1) : ON,: OFF, /: ON or OFF (2) Cooling and heating also include auto mode. (3) Off if jumper wire (J3) is short circulated (factory setting) and open. (4) Cooling operation (a) Cooling 1) If the sum of selected and required frequencies is not larger than the maximum frequency, the required frequencies listed in the following table apply. If the sum of required frequencies is larger than the maximum frequency, the required frequencies divided proportionally apply. Frequency bands for indoor unit models Model (Indoor) Category All series 22 model 28 model 36 model 45 model 56 model 71 model 90 model 112 model 140 model Required frequency (Hz) 10 ~ 15 10 ~ 20 10 ~ 25 10 ~ 25 15 ~ 30 15 ~ 40 15 ~ 50 35 ~ 60 35 ~ 70 Selected frequency (Hz) 5 ~ 15 5 ~ 20 5 ~ 25 5~ 25 5 ~ 30 5 ~ 40 5 ~ 50 5 ~ 60 5 ~ 70 Notes (1) Frequency during cooling is 45 Hz. (2) The required frequency is counted in the unit of 5 Hz and the selected frequency in the unit of 1 Hz. 2) This indoor unit electronic expansion valve (EEV) controls opening of each indoor unit corresponding to decision frequency. Also, the thermostat is sampled in pitch of 20 second. (b) Cooling thermostat off (i) When all thermostata of indoor unit in a module are turned off, the indoor units operate in the cooling thermostat off mode per outdoor unit module. (ii) When the decision frequency to indoor units is less than 5Hz, or when the demand frequency reaches to the OFF area according to fuzzy operation, the ndoor units will select the cooling thermostat of mode. 1033 FDC-HKXR (5) Dehumidifying (Thermal dry) D C Low -2 B A +2 ▲ High Room temperature setting point • Indoor unit fan will be operated in D block as shown below. 20 sec. Lo OFF 4 min. Temperature check (6) 22 model 28 model 36 model 45 model 56 model 71 model 90 model 112 model 140 model Compressor Indoor unit electronic expansion valve Indoor unit fan Outdoor unit fan Indoor unit frequency (Hz) Operation block • This cooling operation is mainly for dehumidifying, with which the compressor, indoor and outdoor fans are operated in the patterns as listed in the following table and in accordance with operation blocks switched with the room temperature sensor. The operation blocks are selected by checking the return air temperature at 4-minute intervals. Respective functional items are operated in each operation block as shown by the following table. Operation block A B C D Item 10 15 20 20 25 30 40 50 60 10 10 0 10 10 0 15 10 0 15 10 0 15 15 0 20 15 0 25 15 0 40 35 0 45 35 0 Sum of frequencies on combined indoor units Frequency adaptation Me Lo Lo Lo↔OFF Operationt Operationt Operationt Stop Temperature check Heating operation (a) Heating • This is same as the cooling operation. (b) Heating operation with thermostat OFF 1) Intermittent fan operation control a) When the jumper wire J3 on the indoor PCB is shorted (installed at shipping),the fan of the unit of which the thermostat is turned OFF during heating is operated in the Lo mode, and the indoor fan is turned OFF if the temperature rises 1˚C or more than the return air temperature at the thermostat OFF. b) Indoor fan OFF condition is maintained for 5 minutes and then the operation is reset at the Lo mode again. After operating for 2 minutes in the Lo mode, return air temperature is checked and, if it is 1˚C or higher, the indoor fan is turned OFF or, if it is not higher than 1˚C, the Lo mode operation continues. Notes (1) If the heating thermostat has been turned OFF, the temperature is indicated on the remote controller only when the indoor fan is operated in the Lo mode. When it is OFF, the room temperature at the end of Lo operation is indicated. (2) If the operation is changed to the defrosting mode while the heating thermostat is at OFF or the thermostat is turned OFF during defrosting, the indoor fan is turned OFF. (3) Residual operation of heater is dominant over this control. 2) Fan stop control a) If the jumper wire J3 on the indoor PCB (installed at shipment) is opened or the thermostat is turned OFF during heating operation with the remote control sensor operating, the fan on the indoor unit is turned OFF. (c) Hot start (Prevention of cold draft during heating) If the required frequency in the room is other than 0 Hz at the start of heating operation, the indoor fan is controlled in accordance with the temperature of indoor air heat exchanger (detected with ThI-R). (Setting blow rate) Stop Indoor air heat exchanger temperature (˚C) 1034 Notes(1) When the hot start (the compressor is operating and the indoor unit fan is not operating at the setting blow rate) is going on, the heating preparation is displayed (LCD on the remote controller). (2) When the required frequency is other than 0 Hz, once the blower should start, it will not stop even if the temperature drops below 20˚C. (3) After the blower has been turned OFF for 7 minutes, the blower is operated regardless of the heat exchanger temperature. (For 7 minutes after completion of defrosting during defrosting operation) FDC-HKXR (7) Value shift adjustment of room air temperature detection in heating Under the standard specifications, the room temperature is adjusted at the setting temperature by controlling the indoor unit capacity based on the setting temperature of thermostat and the suction air temperature. However, where the unit is installed in the ceiling and warm air tends to stay around the ceiling, temperature in the living space may not be adjusted at the setting temperature. In such occasion, it is recommended to change the setting of dip switch SW5-2, which is found on the PCB of the indoor unit, to ON position so that the capacity control is tripped at +3 above the setting temperature of thermostat and thus the heating feeling will improve. High Heating capacity -1 High Heating capacity Low +1 Low Heating capacity Thermostat setting temperature +2 +4 Heating capacity Thermostat setting temperature Standard With SW5-2 "ON" Note (1) Refer to page 911 for position of SW (8) Auto Swing Control (Excepted FDR, FDUM, FDFL, FDFU models) (a) Have a louver motor to move the louvers up and down for the so called “AUTO SWING” function. (b) The louver auto swing starts when the AUTO SWING switch is pressed once and stops when the AUTO SWING switch is pressed again. The louver position is displayed on the LCD on the remote controller. During auto swing, the position displayed on the LDC changes, but the positions of the louvers and the display are not coordinated. (The louvers swing3-4 times per minute but the display changes once per second.) (c) Stopping the louvers When the AUTO SWING switch is pressed to stop the louver movement, the LCD louver-position display stops and the louvers stop when they come to the position displayed on the LCD. There are four louver stop position on the LCD. (When jumper wire J2 on the indoor unit printed circuit borad is cut, the louvers stop immediately at the AUTO SWING switch is pressed to stop them and the LCD display changes to show this posiition. Refer to page 180 for position of jumper wire J2. (d) Movement of louver when the power supply to the controller controlling 4 positions of the louver is switched on. When power supply is switched on, the louver will automatically swing about 2 times (without operating remote controller). This is an action for the microcomputer to confirm the louver position in order to input the cycle of the luver motor (LM) to the microcomputer with the limit switch (LS) pushing the louver motor (LM). If the LS action is not input to the microcomputer, the louver will stop within 1 minute after the power supply is switched on and will not move from then on. (e) Keeping the louvers horizontal during heating While HOT KEEP is displayed (during hot start operation or when the thermostat has turned off during heating operation), the louvers stay in the horizontal position to prevent cold drafts, independent of the setting of the AUTO SWING switch (auto swing or stop). The louver position display of LCD displays continuously the original position before this control operation. When the HOT KEEP display goes out, both the louver and the LCD display return to their previous positions. (However, after the power supply to the unit is switched on, the louvers swing two times as a check of the power source frequency, regardless of the setting of the ON/OFF or AUTO SWING switches.) (9) FILTER sign When the operation time (time when the ON/OFF switch is turned to ON) is counted up at 600 hours (1), the filter sign on the remote controller flickers. This condition can be reset any time with the “Filter reset” switch. It is effective also to turn power OFF to reset. Note (1) The function is invalidated if the jumper wire (J4) is opened. (See page 911 for the location of PCB.) 1035 FDC-HKXR (10) Condensate pump motor (DM) control (Only FDT, FDTW, FDTS, FDR, FDUM models) (a) Drain motor is started no sooner than the compressor is turned ON during cooling or dehumidifying operation. The drain motor continues to operate for 2 minutes after the stop of unit operation, stop with the error stop, thermostat stop and at switching from cooling or dehumidifying operation to blowing or heating operation. When there is any unit subjected to oil return control, the drain motor is operated for 3 minutes at such occasion. Note (1) Drain motor may be operated forcibly by turning ON the dip switch SW5-3 on the PCB. Turn the switch OFF to stop the drain motor. (b) Overflow detection is always operable by means of the float switch regardless of operation modes. If the overflow is detected (or when the float switch is disconnected or its wire is broken), operation is stopped with the error stopped. (FDT, FDTW, FDTS, FDR and FDUM) If the overflow is detected while the drain motor is stopped, the drain motor is operated for 3 minutes and then the overflow detection is performed to judge whether it is normal or not. Indoor unit operation mode OFF (1) COOL DRY During compressor ON FAN (2) HEAT Control A During compressor OFF Notes (1) Including OFF and error stop during COOL, DRY, FAN and HEAT. (2) Including “FAN” operation due to unmatch of operation mode. Control B • Flow chart of drain motor operation Float switch operation (Contactor : Open) Control B Operation mode? Control A *1 NO Drain motor ON Error stop E9 Drain motor ON 3 minutes after float operation? Compressor OFF YES 3 minutes after float operation? Drain motor OFF NO 10 seconds after drain motor OFF? YES Reset Operation Reset Drain motor OFF Error stop E9 continues Float SW? Operation End Float SW? Float operation? Error stop E9 Drain motor 3-minute ON Drain motor ON continues * 1 In the flow in the frame of broken line, operations of operation mode change and thermostat reset are effective and operated immediately upon selection. However, the compressor ON command is not transmitted. (i) Control A a) If the float switch detects the draining, operation is stopped with the error stop (E9 is displayed) and operate the drain pump. b) Float switch is checked 3 minutes later on the unit stopped by the error and, if the error persists still, the drain motor is left at ON but, if the error has already been reset, the drain motor is turned OFF. E9 is displayed till the error is reset. (ii) Control B a) If the float switch detects the draining, the expansion valve is closed, the drain motor is turned ON for 3 minutes and, as 10 seconds elapses after the drain motor OFF, the float switch is checked. If the result is normal, the operation stops in the normal way while, if it is not normal, E9 is displayed, the drain motor is turned ON and the operation stops with the error stop with the expansion valve being closed completely. (It is left at ON while the draining is detected.) 1036 FDC-HKXR (11) Defrosting (a) Conditions for starting defrosting When all the following conditions are met, the defrosting operation will start: -2°C Outdoor unit heat exchanger temp. (ThO-R) 1) The cumulative operating time of the compressor comes up to 45 minutes after completion of a defrosting operation, or it comes up to 30 minutes after a heating operation starts (the remote controller is turned on). 2) Five minutes has passed after the compressor was turned off and on. 3) Five minutes has passed after end of outdoor unit fan motor control. 4) After all the above conditions have been met, the temperature of the heat exchanger sensor (ThO-R) has been below the defrosting start temperature for three minutes in succession. ) -2 -5°C -10°C In i -15°C Ini ti a ti a t t io n n ti o em te m p. p f .o o de ef fd fro ros s g tin tin g a (C a (S t se nd of ard ON 3 SW ) Zone for initiate temp. of defrost -20°C -20°C -15°C -10°C -5°C 0°C 5°C 10°C Outdoor air temperature (ThO-A) (b) Operation of functional components in defrosting Defrosting Finishing of defrosting, Finishing of start defrosting defrosting Heating Defrosting start 1 min. Frequency 95Hz 1 min. Designated Hz 0 65Hz 4 min. 65Hz 0 1'45" 1'45" Outdoor unit fan ON or OFF ON or OFF 5 sec. 4-way valve (20SL,SS) Solenoid valve (SVL,SVS) [Indoor unit electronic expansion valve (EEV)] Heating unit (include, pause) COOL, DRY unit (include, pause) Target Hz 5 sec. ON ON ON or OFF ON or OFF Full open to Hz <Pause, stop> (Open of about 7%) to Hz <Pause, stop> (Open of about 7%) to Hz ON or OFF Full open Closed <Pause, 0> to Hz <Pause, Closed> Full open FAN unit, Stop unit and COOL, DRY unit Output of heating Closed, 0 Closed ON or OFF ON or OFF Heating Defrosting operation Heating (c) Conditions for finishing Defrosting When any of the following conditions is met, the defrosting finishing operation will start. 1) When the temperature of the heat exchanger sensor (ThO-R) increases adove 20°C 2) When 12 minutes has passed after start of defrosting. 1037 FDC-HKXR (12) Multiple Units Control-Simultaneous Control of 16 unit with one remote controller (a) Function Multiple units (even of outdoor different systems, 16 units maximum) can be simultaneously controlled by using a remote control switch (a special order item). The remote control switch is used to set the “operation mode”, and all the unit can be operated and stopped at intervals of 0.5 to 1 second in the order of unit number. Thermostat and protective functions of each unit functions independently. Note(1) When part of the group gets out of order (the protective device operates), the relevant unit comes to an abnormal stop, but other normal units keep operating. (b) Wiring Procedures (i) Lay power cable of each unit and signal wire as usual. (Remove the remote control switches from all units excluding only one unit.) Lay wiring for the remote controller separately from power cable and wires for all other electrical equipment. (ii) Arrange the terminal block (X, Y, Z) of the remote controller as shown next page for the simultaneous control, and lay cross over in each indoor unit. Signal (1) wire Outdoor unit Signal wire Indoor unit No.1 Indoor unit No.2 Outdoor unit (1) Indoor unit No.3 Indoor unit No.16 (2) (2) Remote control signal wire Remote control signal wire Notes (1) The overall length of the signal wire shall be less than 1000m. (2) The length of remote control signal wire and crossover for remote controller between room shall be less than 600m. (13) External control (remote display)/control of input signal (a) External control (remote display) output Following output connectors (CNT) are provided on the control circuit board of indoor unit. (i) Operation output: Power to engage DC 12V relay (provided by the customer) is outputted during operation. (ii) Heating output: Power to engage DC 12V relay (provided by the customer) is outputted during the heating operation. (iii) Compressor ON output: Power to engage DC 12V relay (provided by the customer) is outputted while the compressor is operating. (iv) Error output: When any error occurs, the power to engage DC 12V relay (provided by the customer) is outputted. (b) Control of input signal (Make sure to connect the standard remote control unit. Control of input signal is not available without the standard remote control unit.) Control of input signal (switch input, timer input) connectors (CNT) are provided on the control circuit board of the indoor unit. However, when the operation of air conditioner is under the Center Mode, the remote control by CnT is invalid. (i) At shipping from factory (SW5-1 on PCB OFF) 1) Input signal to CnT OFF → ON [Edge input] Air conditioner ON 2) Input signal to CnT ON → OFF [Edge input] Air conditioner OFF ON ON CnT Input OFF A Unit OFF B Unit ON ON ON OFF OFF ON ON OFF 1038 OFF OFF OFF FDC-HKXR (ii) When SW5-1 on the PCB of indoor unit is turned on at the field. Input signal to CnT becomes valid at OFF → ON only and the motion of air conditioner [ON/OFF] is inverted. ON CnT Input OFF A Unit OFF ON OFF OFF ON OFF OFF B Unit ON OFF (14) Snow Fan Control Set the dip switch SW3-3 (See page 1075) on the outdoor unit control circuit board to ON, and the outdoor fan of a standing unit is operated at the Hi speed for 10 seconds every 10 minutes when the outdoor air temperature drops below 3°C. ON OFF 5°C 3°C (Outdoor air temperature) (15) Control of Coompressor Capacity Notes (1) Full load operation frequency: 35Hz~95Hz(every 5Hz) (2) Hot gas bypass operation frequency: 35Hz~45Hz(every 5Hz) (3) The change-over occurs when 5 minutes of more operation time has passed. Capacirty Fu ll lo ad When the load is set as low as less than 35Hz of full load operation frequency (1) to expand the capacity control range in the low load area, a hot gas bypass (2) (full load conversion frequency:23Hz to 35Hz) is selected. (20VF: OFF, 20VU: ON) Also, when the full load conversion frequency comes to over 35Hz during a hot gas bypass operation, a full load operation is selected. The compressor starts with a hot gas bypass all the time and, after 15 seconds, selects the load and the frequency according to the demand(decision) frequency. Hot gas bypass 0 10 20 3035 40 45 50 55 60 70 80 90 Ferquency (Hz) (16) High pressure control The high pressure control consists of the HP protection, HP-A control, HP-B control and LP control and the order of priority among them is assigned as HP protection >HP-A > LP > HP-B down > HP-B up. HP protection Pressure switch [If 63H1: 3.24 open/2.65 close MPa (33 Open/27 close kgf/cm2) is actuated twice within 45 minutes, the operation is stopped due to the error and the check and indication (Remote controller: E40, indoor LED-green; repeated flickers, red: dark, outdoor LED-green; reperted flickers, red; 3 flickers) are performed. In case of initial operation, however, the compressor is stopped and after a delay of 3 minutes it returns to the normal operation.] HP-A control • If the pressure switch (63H2) is actuated, the outdoor blower is opreated in the Hi mode (for the operations of patterns A1 to C1) or stopped (for the operations of patterns C2 to E2) and, if it is still actuated 2 minutes after a drop of 10 Hz in the inverter frequency, the frequency is dropped futher by 10 Hz. (Minimum frequency is specified at the partial load of 35 Hz.) • Operation returns to the normal mode after operating with the frequency control at off(1) 6 minutes after the 63H2 having been reset. Note (1): If the high pressure A control is released,the frequency is raised by 5 Hz and retained at the level for 3 minutes. The frequency is then raised by 5 Hz at 3-minute intervals till it returns to the normal operation. 1039 FDC-HKXR LP,HP-B controls Under these controls, the high and low level pressures are controlled with the solenoid valves, outdoor fan and other so as to operate the outdoor unit in the optimum condition in accordance with changing load on the indoor unit. Operation patterns consist of the following 12 types and respective functional parts are controlled per each pattern. Table of operation patterns and operations of functional parts Operation Pattern A1 A2 B1 B2 B3 C1 C2 D1 D2 D3 E1 E2 Four-way valve 20SS 20SL SVS Solenoid Valve SVL SV2 SV3 Fan motor FM02 FM01 HI HI HI HI HI HI Me HI HI Me Me HI HI HI HI HI HI Notes (1) and mean ON and OFF respectively. (2) Hi and Me mean the high and medium temperature operations respectively. (3) When the fan motor FM01 is in the Me mode, the solenoid valve SV3 is interlocked via a relay. (SV2 open) • LP control If the pressure switch [63L: 1.96 close/2.75 open MPa (20 close/28 open kgf/cm2)] is actuated, the operation pattern is changed by one step in the direction of A1 to E2 so as to raise the low level pressure by controlling the heat exchanger capacity. • HP-B down control If the pressure switch [63H3: 2.11 close/2.50 open MPa (21.5 close/25.5 open kgf/cm2)] is actuated, it enters the HP-B down control and the operation pattern is changed by one step in the direction of E2 to A1 so as to lower the high level pressure by controlling the heat exchanger capacity. • HP-B up control If the pressure switch [63H4: 1.86 close/1.67 open MPa (19.0 close/17.0 open kgf/cm2)] is actuated, it enters the HP-B up control and the operation pattern is changed by one step in the direction of A1 to E2 so as to raise the high level pressure by controlling the heat exchanger capacity. • Setting the initial operation pattern Indoor load Initial operation pattern When the compressor is started, the operation starts wish one of the following Cooling only A1 operation patterns in accordance with the indoor load. A1 Cooling > Heating B1 Cooling = Heating • Timing to change operation pattern C2 Heating < Cooling Operation pattern is changed by one step at the actuation of the pressure switch (63L, D1 Heating only 63H3 or 63H4). Once the operation pattern is changed, the same operation pattern is maintained for 2 minutes. However, when the frequency which was requested from the indoor side has changed 20 Hz or more, the operation pattern is changed by one step at the actuation of the pressure swich even if it is within 2 minutes. • Changing of operation pattern after a larger change of load Operation pattern When the indoor load has changed largely like a case when scales of Change from heating large to cooling large To A1 heating/cooling loads have been inverted, for example, the operation Change from cooling large to heating large To D3 pattern is changed as follows. 1040 FDC-HKXR (17) Compressor operating frequency increase control (a) In the case that at least one in-door unit requires the maximum frequency supply during cooling or heating operation for 6 minutes continuously, the compressor operating frequency is increased by 10 Hz. After that, the maximum frequency is increased by 10 Hz every continuous 6 minutes; however, the upper limit is 30 Hz. (b) When requirement of the maximum frequency ceases, the control is released. (c) When the protective function of frequency suppressing is activated during control, the protective motion is performed at the condition of increased frequency as the base. (Example: When the current safe is activated at the condition of +20 Hz compensation) 50 Current safe Required Hz 40 from in-door unit Current safe released In-door unit requirement 30 With +20 Hz compensation 60 Compressor operating Hz 50 Without +20 Hz compensation 40 (18) Control at heating change over When one of the in-door units is changed over from "Cooling (including automatic), dehumidification and ventilating mode" to "Heating (including automatic) mode", or from "Heating mode" to "Cooling, dehumidification and ventilating mode", the following control is performed. (a) During compressor is operating 1) The heating output is kept at the output condition just before cooling/heating change over for 2 minutes and 45 seconds, after that the heating output of in-door unit where cooling/heating has been changed is changed over. 2) The 4 way valve (20SL, 20SS) is changed over at 2 minutes after the compressor stopped. 3) The compressor starts operation with the operation pattern shown in the following diagram after 3 minutes' stop. Heating Operation mode Cooling In-door unit Heating output ON OFF 2 min. and 45 sec. 2 min. and 45 sec. 3 min. 3 min. ON Compressor OFF 2 min. 4 way valve (20SL, 20SS) 2 min. ON or OFF Initial operation pattern Initial operation pattern (b) When the compressor has kept on stopping for 2 minutes and 45 seconds or more: 1) The heating output is changed over immediately. 2) The motion of compressor and 4 way valve is the same manner as described in Article (a). (c) When the stop time of compressor is less than 2 minutes and 45 seconds: 1) The heating output is changed over after 2 minutes and 45 seconds has passed since the compressor stop. 2) The motion of compressor and 4 way valve is the same manner as described in Article (a). 1041 FDC-HKXR (19) Devices related to unit protection and maintenance (a) Test Run Mode The test run mode can be set from the outside by using the switch SW3-4,5 on the outdoor unit control circuit board (i) Switch function Switch SW3-4 SW3-5 Function ON • To operate all connected indoor units. • Indoor units demands the maximum frequency and outdoor units are operated with the maximum frequency according to request from the indoor unit. OFF • Normal operation ON • When SW3-4 is set to ON: Cooling operation OFF • When SW3-4 is set to ON: Heating operation (ii) The maximum frequency of outdoor unit in test run operation (At the time of rated capacity) Model FDCP2001,2501 type Maximum operation frequency (Hz) 95 Remarks : Fuzzy control is not performed in test run operation. (Operation is executed.) Other controls are effective. (b) Expansion Valve Control for oil Return After the compressor operated for 10 hours, and when the compressor is turned, stop the compressor to collect refrigerant oil, turn off the thermostat, and fully open indoor unit expansion valves of FAN and adnormally stopped units one by one. (Open expansion valves in the sequence that addresses were registered to outdoor units and not of the address number. (c) High Pressure Control in Heating Operation When (63H2) [2.84 close/2.26 open MPa (29.0 close/23.0 open kgf/cm2)] operates, the compressor revolution decrease 10 Hz, and outdoor unit fan stops preventing pressure increase. Frequency control is canceled after 6 minutes from reset of 63H2, then the compressor returns to the normal operation. Note (1) Detail of Frequency Control Canceling Operation When a high pressure control is canceled, the frequency increases 5 Hz, and the frequency is retained for 3 minutes. The frequency increases 5 Hz every 3 minutes to the normal operation. (d) Discharge gas Temperature Control (All Operation Modes) When the discharge gas temperature (discharge gas thermistor : ThO-D) increases above the set point, the temperature (detected with ThO-D) is controlled by opening and closing the liquid bypass solenoid valve (SV1) and by lowering the frequency. Note (1) ThO-D > 115°C .......SV1-Open [ThO-D < 108°C Closes] The expansion valve of operating indoor unit open 5% approx. ThO-D > 120°C .......The frequency is lowered 10Hz each time at intervals of 2 minutes (Lower Limit: 35 Hz of the full load or a hot gas bypass.) (ThO-D = < 115°C are canceled) ThO-D > 130°C.......abnormal stop [The operation can be resumed at a temperature bellow 90°C] (e) Compressor Control at the during of startup (i) Inrush Current the compressor with 5Hz to the starting. Also, at the time of startup, fully open the expansion valve of the indoor unit in the operator cab for 4 minutes. (ii) Protective Start of Compressor When the inverter starts, the compressor start under protection. Operate with hot gas bypass up to 35 Hz after the start, operate with full loads of 60 Hz for 15 seconds, then operate with the decision frequency. When the frequency is higher than 65 Hz, they operate with 65 Hz for one minute 45 seconds after the start. But when the compressor starts first time after the power is turned on, and when the compressor starts after stop for more than 6 hours, it increases the frequency 5 Hz each minute for 13 minutes. 1042 FDC-HKXR (iii) Three minutes delay timer The compressor (inverter) will remain in stop state for 3 minutes, when the compressor is stopped by thermostat, ON/OFF swich, and /or by occurrence of trouble. When the power source is turned ON, the 3-minutes delay timer is cancelled. (f) Detection Control of Electricity Supply to Crank Case Heater When an operation starts less than 6 hours after the power is turned on (electricity is supplied to CH), the frequency is controlled as follows: (to the decision frequency) (Hz) 70 60 50 40 30 20 5Hz/minutes 10 0 5 10 15 20 25 Notes (1) When the operation stops within 33 minutes, this control is executed at the time of the second or later startup. (2) Operate with hot gas bypass up to 35 Hz, then with 60 Hz for 15 seconds. 30 33 (minutes) (g) Open-phase Protection When the T-phase voltage of the secondary side of 52C is 0V, an abnormal stop will occur and the inspection displays (Remote controller : E34, indoor unit green LED : Continuous flashing, red LED : OFF, outdoor unit green LED : red LED : 2 times flash) will appear. (h) Current Safe Control The operation corrent is automatically controlled. When the operation current at the converter inlet increases, the frequency is lowered 5 Hz by 5 Hz so that the operation current does not increase above the set point. Lower limit frequency: Hot gas bypass 35 Hz 1) Retain the operations with hot gas bypass of 35 Hz for 3 minutes, and when it is foud to be the current safe value, stop the inverter, operate them with hot gas bypass 3minutes later for 3 minutes. When the frequency is below the current safe value, operate them with full loads of 35 Hz, cancel the frequency control to bring them back to the normal operation. 2) When the decision frequency under the fuzzy control get lower than the current safe frequency during a current safe control, bring them back to the normal operation. When the current value comes to the current cancel value during a current safe control, retain the frequency for 3 minutes, then cancel the frequency control. (i) Current Cut Control This control aims to prevent over current in the converter. When the current increases above the set point, stop the inverter immediately, then let is reset by itself 3 minutes later. After the self-reset, start the inverter with 35 Hz, and increase the frequency 5 Hz every 3 minutes to let it return to the fuzzy indication frequency. When the current is cut four times in 15 minutes, turn off 52C bring it to an abnomal stop and the inspection displays (Remote controller : E42, indoor unit green LED : Continuous flashing, red LED : OFF, outdoor green LED : Continuous flashing,and red LED : 1 time flash will appear. (j) Protection of Power Transistor from Overheat When the temperature of the power transistor increases to the set temperature, stop the inverter immediately and let is reset by itself 3 minutes later. If the power transistor is overheated again within 2 hours, turn off 52C, bring it to an abnormal stop and the inspection displays (Remote controller : E41, indoor unit green LED : Continuous flashing, red LED : OFF, outdoor unit green LED : Continuous flashing, red LED : 4 times flash) will appear. 1043 FDC-HKXR (k) Protection of Power Transistor from Overheat When the temperature of the power transistor increases to the set temperature, stop the inverter immediately and let is reset by itself 3 minutes later. If the power transistor is overheated again within 2 hours, turn off 52C, bring it to an abnormal stop and the inspection displays (Remote controller : E41, indoor unit green LED : Continuous flashing, red LED : OFF, outdoor unit green LED : Continuous flashing, red LED : 4 times flash) will appear. (l) Protection of Number of Connected indoor Units When the number of connected indoor units exceeds the quantities shown in the table below, they will come to an abnormal stop, and the inspection displays (Remote controller E43, indoor unit green LED : Continuous flashing, red LED : OFF, outdoor unit green LED : Continuous flashing, red LED : 7 times flash) will appear. Number of connected units FDCP2001 type FDCP2501 type 8 units 8 units (m) Frost prevention during cooling To prevent frost during a cooling operation, check temperature (to be detected with ThI-R) of the indoor unit heat exchanger and lower the frequency of indoor unit (opening of expansion valve) when the temperature drops below 3°C. When the heat exchanger temperature is below 2°C for more than 2 minutes, turn off the thermostat and start a ventilating operation. If the heat exchanger temperature rises above 16°C after the thermostat is turned off, reset it to a cooling operation. But this operation shall not be executed for 10 minutes after the thermostat is turned on. Also when temperatures of standing units have been below 2°C for an hour in succession, turn off the compressor for 3 minutes. (n) Control of Temperature under Dome The liquid bypass solenoid valve (SV1) is controlled according to the temperature of the thermistor (ThO-C) under the dome fitted to the compressor. Full Load Open Close 55°C 1044 Hot gas bypass Open Close 65°C 30°C 40°C ThO-C > 65°C SV1 open ThO-C > 40°C SV1 open ThO-C < 55°C SV1 close ThO-C < 30°C SV1 close FDC-HKXR 20.5 APPLICATION DATA SAFETY PRECAUTIONS • Please read these “Safety Precautios” first then accurately execute the installation work. • Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION , those points which are related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the WARNING section. However, there is also a possibility of serious consequences in relationship to the points listed in the CAUTION section as well. In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned. • After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner’s manual. Moreover, ask the customer to keep this sheet together with the owner’s manual. WARNING • This system should be applied to places of office, restautant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction. • Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires. • Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires. • When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you purchased the equipment, and make the installation accordingly. In the rare event that a refrigetant leakage and exceeding of threshold concentration does occur, there is the danger of a resullant oxygen deficiency accident. • For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit. • Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. • For electrical work, please see that a licensed electrician executes the work while followig the safety standards related to electrical equipment, and local requlations as well as the installation instructions, and that only exclusive use circuits are used. Insufficient power source circuit capacity and defective installment execution can be the cause of electric shocks and fires. • Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire. • Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire. • When setting up or moving the location of the air-conditioner, do not mix air etc. or anything other than the designated refrigerant within the refrigeration cycle. • Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage. CAUTION • Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock. • The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may reslut in electric shock. • Do not install the unit where there is a concern about leakage of combustible gas. The rare event of leaked gas collecting around the unit could result in an outbreak of fire. • For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items. 1045 FDC-HKXR 20.5.1 Installation of indoor unit This is same as multi KX series. Refer to page 841~881. 20.5.2 Installation of the remote controller (Optional parts) This is same as multi KX series. Refer to page 882. 20.5.3 Installation of outdoor unit (1) Selection of installation location (a) A palce where air will not be stagnant. (b) A place where the exhaust air will not be shorteyeled. (c) A place with enough space for air flow around the unit. (d) A place where the unit will not be affected by other heat sources. (when there are multiple units installed or when units have another heat source) (e) A void installing the unit in places that are subject to sea air, sulfureous gas of the type found in hot springs, or any other (f) A place where smooth drainage of rain water and water formed by defrosting is acceptable. (g) In heating operation, snow deposit on the heat-exchanger of outdoor unit must be prevented for keeping the normal corrosive or flammable gas. performance capacity. • Snow-hood no outdoor unit as in drawing, will reduce the frequency of defrost operation. When installing the snow hood, take care so that the air outlet of the snow hood will not face directly into the most windy direction. • (h) Design the base higher than possible snow deposit. A place where air outlet port is not exposed to strong wind. (2) Installation space A place with enough space for air inlet, air outlet and service space. (a) Independent installation Dimension Installation example Unit: mm I II III Distance 1) L1 open open 500 L2 0 500 500 L3 200 200 200 L4 500 0 500 When there are obstacles on the sides and at the rear side of the unit Note (1) The unit can be installed bringing the right side close to the obstacle. In that case, provide a space over 500 mm to the left side. 1046 FDC-HKXR 2) When there is an obstacle above the unit Note (1) The side air outlet indicates that a wind direction variable adapter available on the optional parts is fitted to the unit. 3) When there is an obstacle (are obstacles) on the side (in front side of and at the rear side) of the unit 4) When there is an obstacle above the unit as well 5) When there is no obstacle above the unit Note (1) The side air outlet and the up air outlet indicate that wind direction variable adapters available on the optional parts are fitted to the unit. 6) When installed in a narrow space (there are obstacles in front side of and at the rear side of the unit.) [Remarks] When there is a space above the unit, install the unit in the same way as you do when there is an obstacle (are obstacles) on a side (in front side of and at the rear side) of the unit. 1047 FDC-HKXR 7) Installation where there is obstacle on all four sides. Note (1) The up air outlet indicates that a wind direction variable adaptor available on the optional parts is fitted on the unit. (b) Installation of multiple units 1) Continuous installation on side-to-side [The front side is open] [Keep a space of more than 10 mm between the units] Note (1) There shall be no obstacle above the unit. [Remarks] When the unit is installed continuously side by side, any multiple units can be installed. 2) Continuous Installation on side-to-side [There are obstacles in front side of and at the rear side of the unit.] [Keep a space of more than 10 mm between the units] Note (1) The obstacle at the rear side shall be lower than the unit, and the obstacle in front side shall be less than 1000 mm. [Remarks] When the unit is installed continuously side by side, any multiple units can be installed. Note (1) When an up air outlet is selected optionally, the obstacle in front can be made lower than the unit. 1048 FDC-HKXR 3) Face-to-face installation Dimension Distance L1 Item Diagonal 1500 or more 1000 or more 500 or more 500 or more Up air outlet Unit: mm L2 Note (1) Make the air outlet the diagonal air outlet (standard) or the up air outlet (option). 4) Side-to-side & face-to-face installation [Keep a space of more than 10 mm between the unit] Dimension Distance L1 Item Diagonal 1500 or more 1000 or more 800 or more 800 or more Up air outlet Unit: mm L2 Note (1) Make the air outlet the diagonal air outlet (standard) or the up air outlet (option). 5) In the case where the unit is exposed to strong wind. a) Face the unit air outlet at a 90º angle from the direction of the wind. b) Securing outdoor unit (in the case of exposure to severe weather conditions) Fix the unit in the following way. • Use overtuming prevention brackets. • Rig with wires. (Use rigging wires that are resistant to corrosion and sufficient in strength. For example SUS304-W1, wire thick-ness 2.9 mm) 1049 FDC-HKXR (3) Installation Fix the unit in a proper way according to the condition of a place where it is installed by referring to the following. (a) Fix the unit to the foundation with anchor bolts. Unit: mm 1050 (b) When installing the unit, be sure to fix the pedestal of the unit with bolts. (c) Install the unit securely not to be fallen by earthquake or strong of wind. (d) Prepare a concrete foundation referring to the above figure. FDC-HKXR 20.5.4 Refrigerant piping (1) Precautions no refrigerant piping work for prevention against compressor lock Compressor trouble including lock and motor burn-out is due to faulty parts but mainly concerned in installation and refrigerant piping conditions, The precautions for refrigerant piping are as belows. (a) Be sure to perform brazing while flowing nitrogen. 1) Without flowing nitrogen gas, a lot of oxide film (CU2O) is generated. In particular, in case of for building with many 2) A foreign material (oxide film) causes clogging of the capillary tube or expansion valve, leading to non-cooling (non- brazed portions, oxide film is so much generated that this causes a fatal failure in the air conditioning system. heating), abnormal discharge temperature, compressor lock due to a faulty oil return. In some cases, a lot of foreign materials block the oil return hole of the accumulator, thereby causing a compressor lock. (This lock trouble may occur repeatedly 2 or 3 times.) (b) Don’t admit water (waterdrops, condensation) into the piping. 1) Use a copper piping that is free from water (waterdrops, condensation). 2) Don’t perform refrigerant piping work while it rains. 3) To suspend outdoor piping work, perform curing to prevent water admission. Bad effects of water • Capillary tube and expansion valve clogging • Refrigerant hydrolysis → “Acid” generation There will be directly conected to serious → Iron/copper corrosion • trouble such as compressor lock or burn- Crystal foreign material (clathrate compound) out of the compressor motor. generation resulting from reaction on refrigerating machine oil (c) Don’t admit dust or foreign particles in the pipe. Various foreign particles are included in air conditioners that caused trouble. Be careful about them. (Concrete fragments, cement, sand, paint, metal powder (copper refuse after deburring, etc.), etc. (d) Adopt the specified dimensions for pipes. Too thick: Improper charge volume Compressor lock Faulty oil return (insufficient gas flow rate) Too long (L): Overcharge Liquid back Compressor lock Faulty oil return (e) Be sure to support the refrigerant piping with support fittings. 1) The pipe vibrates and expands/shinks during operation. Without proper supports, a load is concentrated partially and cracks and collapse occur on the piping, thereby causing a unit failure. 2) A support should be provided at intervals of 2 or 3 m so as not to partially concentrate a load. 1051 FDC-HKXR (2) Refrigerant piping size selection Branch line Outdoor unit connection pipe Indoor unit connection pipe Downstream indoor unit capacity total (1) less than 160 22,28,36,45 (not including 160) less than 90 type 90 or more (not including 90) FDCP2001 type FDCP2501 type 160 or more Liquid piping φ12.7 × 1.0 mm φ12.7 × 1.0 mm φ12.7 × 1.0 mm φ9.52 × 0.8 mm φ9.52 × 0.8 mm Intake gas piping φ25.4 × 1.4 mm φ28.58 × 1.4 mm φ25.4 × 1.4 mm φ19.05 × 1.2 mm φ15.88 × 1.0 mm Discharge gas piping φ19.05 × 1.2 mm φ19.05 × 1.2 mm φ19.05 × 1.2 mm φ15.88 × 1.0 mm φ12.7 × 1.0 mm Flow divide controller connection pipe 56,71,90 type 112,140 type models Indoor side Outdoor side φ6.35 × 0.8 mm φ9.52 × 0.8 mm φ9.52 × 0.8 mm φ9.52 × 0.8 mm φ9.52 × 0.8 mm φ12.7 × 1.0 mm φ15.88 × 1.0 mm φ19.05 × 1.2 mm φ15.88 × 1.0 mm φ15.88 × 1.0 mm φ12.7 × 1.0 mm Notes (1) This shows the total capacity of the indoor units connected after indicated branch pipe. (2) 1 flow divider pipe set is required for each division. Branch pipe set part shapes (DIS-1KXR3-E) Name Part shape φ25.4 φ19.05 φ19.05 φ15.88 φ12.7 φ19.05 φ12.7 Branch pipe 1 Discharge gas piping 1 Liquid piping 1 Intake gas piping (FDCP2501HKXRE2) φ6.35 128 φ12.7 φ12.7 Intake gas piping Notes (1) Each flow divider pipe is surrounded with insulation. (2) Each pipe is cut off in the middle of the diameter that is used in that locality. φ12.7 424 φ15.88 φ9.52 1 φ12.7 94.5 2 φ25.4 φ15.88 φ19.05 519 ID φ15.88 Remarks φ12.7 φ19.05 φ15.88 1 Quantity φ15.88 φ25.4 119 ID φ19.05 φ9.52 Symbol 3 247 a OD 25.4 Reducer ID 28.58 100 Shapes of accessory parts for brunch pipe set for vertical divides (DIS-V1KXR3-E) φ19.05 φ19.05 φ12.7 Intake gas piping φ19.05 φ6.35 φ12.7 Branch pipe 100 — ID28.58 OD25.4 100 — OD 19.05 Reference 1: Be sure to install the vertical flow divider coupling (both) for gas and liquid) as "vertical divide" as illustrated below. 128 Floor 247 Notes (1) Insulation is provided to all flow divider pipes. (2) Cut off the flow divider pipes in the center to match the diameter of the piping used on site. ID φ25.4 φ12.7 φ9.52 φ15.88 φ12.7 φ15.88 φ12.7 424 φ9.52 Discharge gas piping 3 φ19.05 120 94.5 285 ID φ15.88 φ15.88 φ25.4 φ15.88 φ19.05 φ12.7 φ19.05 φ12.7 φ15.88 98 130 1 2 1052 Classification Symbol Branch pipe ID Liquid piping Intake gas piping Classification Symbol FDC-HKXR (Example) Outdoor unit Discharge gas piping Liquid piping Intake gas piping Flow divider pipe set for vertical divides Indoor unit Individual flow divide controller (DIS-V1KXR3E) Indoor unit Individual flow divide controller When the outdoor unit are installed at a higher level than the individual flow divide controller and a vertical flow divider is required for the piping connections of 2 or more individual flow divide controllers for 1 module, use the "flow divider pipe set" for vertical divides. Flow divider pipe set for vertical divides Part No. DIS-V1KXR3-E Shapes of individual flow divide controller accessories (HPFD1R-E) Name Reducer For outdoor For outdoor intake Application discharge gas piping and indoor gas piping Quantity For outdoor and indoor liquid piping 2 1 In Sulation Relay kit For pipe cover For controller 2 Piping connection Number of divisions 1 OD9.52 OD15.88 OD12.7 Strainer coupline For outdoor discharge gas piping Shape ID15.88 Code ID 19.05 ID 12.7 A ID6.35 B C Example of piping Outdoor unit: FDCP2501HKXRE2 [Total capacity: 348 (34800w)] FDCP Outdoor unit 2501HKXRE2 A Branch piping 1 B Branch piping 2 Branch piping 3 D C Branch piping 4 F G H a b c 112 71 56 Individual flow divide controller Indoor unit Branch piping 5 I d J e K f E Individual flow divide controller 45 36 28 Indoor unit 1053 FDC-HKXR Good Note 1: When making branch connections (for both gas and liquid lines), be sure that the proper horizontal branches and vertical branches are used. No No Vertically Good Floor Floor Horizontally Floor Floor • Selection piping size Item Piping size(mm) Selection procedure A Same as the outdoor unit piping size (FDCP2501HKRE2) B Total capacity of connected indoor units Intake gas line Gas line ø19.05 ø28.58 Liquid line ø12.7 (236) ø19.05 ø25.4 ø12.7 ø19.05 ø9.52 C Total capacity of connected indoor units (165) ø15.88 D Total capacity of connected indoor units (109) ø15.88 ø19.05 ø9.52 E Total capacity of connected indoor units (64) ø12.7 ø15.88 ø9.52 ø19.05 ø9.52 F Total capacity of connected indoor units (112) ø15.88 G Total capacity of connected indoor units (71) ø12.7 ø15.88 ø9.52 H Total capacity of connected indoor units (56) ø12.7 ø12.7 ø6.35 ø12.7 ø6.35 I Total capacity of connected indoor units (45) ø12.7 J Total capacity of connected indoor units (36) ø12.7 ø12.7 ø6.35 K Total capacity of connected indoor units (28) ø12.7 ø6.35 a Indoor unit piping size (112) ø12.7 ø19.05 b,c Indoor unit piping size (71,56) ø15.88 ø9.52 d~f Indoor unit piping size (45,36,28) ø12.7 ø6.35 ø9.52 • Selection of branch piping size. Selection procedure Item Branch pipng set Branch piping 1 Horizontal branch piping set – down-flow indoor unit capacity total. (348) DIS-1KXR3-E Branch piping 2 Horizontal branch piping set – down-flow indoor unit capacity total. (236) DIS-1KXR3-E Branch piping 3 Horizontal branch piping set – down-flow indoor unit capacity total. (165) DIS-1KXR3-E Branch piping 4 Vertical branch piping set – down-flow indoor unit capacity total. (109) DIS-V1KXR3-E Branch piping 5 Vertical branch piping set – down-flow indoor unit capacity total. (64) DIS-V1KXR3-E Piping connection instructions (for the above example) Process the included reducer as illustrated below. Use the flare nuts included with the individual flow divide controller. When the indoor unit capacity is 90 or more A type Use reducer A and process the φ12.7 portion into a flare. ( OD12.7 → ID15.88 ) ID19.05(Brazing) ID19.05(Brazing) B type 70 or more Cut off reducer B using a pipe cutter as shown in the illustration and make a flare. ( OD15.88 → ID19.05 ) ID15.88(Brazing) Reducer B (accessory) When the indoor unit capacity is 50 or less Reducer C (accessory) B type 70 or more ID6.35(Brazing) ID6.35(Brazing) Cut off reducer B using a pipe cutter as shown in the illustration and make a flare. ( OD15.88 → ID12.7 ) ID12.7(Brazing) ID12.7(Brazing) Reducer B (accessory) 1054 FDC-HKXR (3) Specification of unit piping (Pipe diameter. Connecting method) (a) Unit 1) Outdoor unit Unit: mm (in) Item Model 2) Gas line Pipe diameter FDCP2001HKXRE2 φ25.4 (1") FDCP2501HKXRE2 φ28.58 (1 1/8") Pipe diameter Connecting method φ12.7 (1/2") Brazing Brazing φ12.7 (1/2") Indoor unit Unit: mm (in) Gas line Item Pipe diameter Model 3) Liquid line Connecting method Liquid line Connecting method Pipe diameter 22, 28 type φ12.7 (1/2") 36 type φ12.7 (1/2") 45 type φ12.7 (1/2") 56, 71, 90 type φ15.88 (5/8") φ9.52 (3/8") 112, 140 type φ19.05 (3/4") φ9.52 (3/8") Connecting method φ6.35 (1/4") φ6.35 (1/4") φ6.35 (1/4") Flare Flare Tightening torque φ6.35 (1/4") Flare nut 16~20N · m (1.6 ~ 2.0 kg·m) φ9.52 (3/8") Flare nut 40~50N · m (4 ~ 5 kg·m) φ12.7 (1/2") Flare nut 40~50N · m (4 ~ 5 kg·m) φ15.88 (5/8") Flare nut 90~120N · m (9 ~ 12 kg·m) φ19.05 (3/4") Flare nut 100~140N · m (10 ~ 14 kg·m) Gas side flange bolt 30~40N · m (3 ~ 4 kg·m) (b) Refrigerant piping connection 1) Pipes can be connected in four directions, but electric wire can be done in five directions. 2) Select the optimum connecting direction taking into account the installation conditions of outdoor unit and the positional relations with indoor units. 3) For connections to the operation valves and attendant piping, connect gas pipes first, then liquid pipes. • Remove the seal on the flange of the gas side service valve. • Place the accessory packing between the flanges of the gas side service valve and of the attendant piping for gas before connection. 1055 FDC-HKXR (c) How to connect piping 1) Connection to front directions. a) Remove the front hall blank, pass through he hole the intake gas side, gas side and liquid pipes. and then connect then to the service valves and the on-site piping. (Because the liquid side pipe is on-site piping, bend it to the dimensions shown in the illustration at low.) 80 88 75 103 97 250 85 70 100 62 65 80 145 187 2) Connection to lower direction. a) Cut off the accessory intake gas side connection pipe and then connect to the intake gas side atraight pipe. b) Remove the back hall blank, pass through the hole the intake gas side, discharge gas side, and liquid pipes, and then connect them to the operation valve and the on-site piping. (Because the liquid side pipe is on-site piping, bend it to the dimensions shown in the illustration at left.) 85 62 65 80 70 100 65 Intake gas side (Accessory) Liquid pipe (On-site piping) 60 Intake gas side connection pipe (Accessory) 75 43 (Accessory) 250 Gas side connection pipe Back 40 105 107 100 1056 Half-brank FDC-HKXR (4) Heat insulation (i) There is a need to insulate both gas and liquid piping with heat insulation for protection against heat and condensation. 1) Always use heat insulation to prevent condensation on the gas piping from becoming drain water and causing leakage during cooling and to prevent people from being burned by the high temperature of the surface of the gas piping as discharge gas flows through it. 2) Use heat insulation (pipe cover) on the flare connection sections of the indoor unit. (Insulate both the gas and liquid piping.) 3) Insulate both the gas and liquid piping. Apply the insulation so that is tight against the piping and free of gaps. Route the connecting wires with the insulation and wrap the entire bundle with exterior tape. ; ;;; ;;; ;;; ;;; ;;; ;;; Wires for connecting indoor and outdoor units Liquid piping Exterior tape Gas lines Insulation Use insulation material with good resistance heat properties (120 ˚C or more). (5) Air-tight test (a) When conducting an air-tight test of local piping, connect the piping to the check joint of the evacuating pipe connected to the gas side service valve, and keep the service valve closed. The air-tight test pressure shall be 3.23MPa(33 kgf/cm2.) (b) To conduct the test, pressurize the check joint of evacuating pipe by nitrogen gas as shown below. The local piping including indoor units can be tested as for airtightness. (6) Evacuating Evacuating can be completed faster by evacuating both the check joint on the liquid side service valve and the check joint of the evacuating gas pipe (accessory) connected to the gas side operation valve at the same time. (Of course, evacuating is possible even through the liquid side check joint only.) 1057 FDC-HKXR (7) Refrigerant charge amount (a) Additional; charge amount Item Additional charge amount per 1 m of liquid pipe Factory charge amount at time of shipment Indoor unit φ12.7 φ9.52 φ6.35 Outdoor unit Model FDCP2001HKXRE2 0.12 kg/m 0.06 kg/m 0.03 kg/m 11.0 kg Holding charged FDCP2501HKXRE2 Remarks Additional refrigerant Charge is not required Notes (1) When the refrigerant piping length exceeds the length that additional refrigerant charge is not required, charge additional refrigerant based on to calculated amount of refrigerant per unit piping length. (2) The unit is holding charge type that all of the refrigerant is charged in the outdoor unit and in the indoor unit only a small amount of refrigerant is filled for prevention of the air entry. Calculation of amount of refrigerant to be charged in local piping The amount refrigerant additionally charged in local piping depends on connection pipe size but not on indoor unit type. [Amount of refrigerant to be charged in the local piping = Actual length of liquid pipe × Amount of refrigerant additionally charged per meter of liquid pipe] [Example] Amount of refrigerant additionally changed = (I1 × 0.12) + (I2 × 0.06) + (I3 × 0.03) I1 : Overall length (m) of φ12.7 liquid pipe I2 : Overall length (m) of φ9.52 liquid pipe I3 : Overall length (m) of φ6.35 liquid pipe Following precautions must be observed when the model is adapted to R407C. (1) Tools and related components should be changed when handling a different kind of refrigerant in order to prevent mixing of different oils. Gauge manifold and charge hose, particularly, should never be used after using them for R22. (2) Charge cylinder should not be used. Otherwise, the refrigerant composition may change when charging R407C into the cylinder. (3) Refrigerant should be charged in the liquid phase from the container. Charging the refrigerant in the gaseous phase could change the refrigerant composition substantially. (4) Volume of refrigerant to be taken out in the liquid phase from the container should be up to 90% of necessary quantity (in weight percent) as a standard. (5) Refrigerant should not be replenished even if a leakage is discovered because it could change the refrigerant composition substantially. When a leakage is discovered, replace with new refrigerant in the specified volume. However, it could be replenished temporarily in case of an emergency. 20.5.5 Electrical wiring (1) Power supply wiring (a) Outdoor unit power supply (A separate power supply is used for the indoor unit) Item Model Short-circuit breaker Ground wire Power Power supply Wire Wire circuit breaker (A) (Use for both pround/ overload and short- Thickness Screw type supply wiring thickness length (mm) (mm2) (m) Rated current Switch capacity circuit production) FDCP2001HKXRE2 3-phase 380/415V FDCP2501HKXRE2 50Hz 5.5/5.5 46/54 40/40 30/30 40A100mA 0.1sec or less 8.0/8.0 47/58 60/60 50/50 50A100mA 0.1sec or less 5.5/5.5 M6 (b) Indoor unit power supply Item Supported outdoor model Thickness of Circuit Wire circuit Short-circuit breaker Signal wire thikness (mm2) Power Power supply Wire power supply Breaker breaker (Use for both pround/ wire between Switch luse rated current overload and short- Between outdoor Between supply wiring thickness length indoorunits capacity (A) circuit production) and indoor units indoor units (mm2) (m) (mm2) (A) FDCP2001HKXRE2 1-phase 220/240V FDCP2501HKXRE2 50Hz 1058 2.0/2.0 37/37 2.0/2.0 20/20 20/20 20A30mA 0.1sec or less 2 core × 0.75 ~ 2.0 Same as at left FDC-HKXR (c) Individual flow divide controller (Same power supply with the indoor units) Power supply wiring thickness (mm2 × number of wires) Item Power supply Supported model Signal wire thickness (mm2 × number of wires) 1-phase 2.0/2.0 × 2 220/240V 50Hz Note (1) Do not misconnect the central flow divide controller signal wire. 2.0 × 2 HPFD1R-E (2) Precaution in electric wiring. (a) Use separate power supplies for the outdoor and indoor units respectiveliy (Standard specification) (b) Signal wiring (for indoor and outdoor units) Double-core cable with a diameter 0.75 to 2 mm2 should be used for the signal wires. Never make the indoor and outdoor connecting signal line use “co-axial cable” or “strand” with the power wiring for indoor and outdoor unit and other ower line. (Never use a multiconductor wire together with power line. It may cause erroneous operation.) Do not connect high voltage wires 220/240 V or 380/415 V to signal wires. as these wires are DC 5V. Signal wires should be connected so that the terminal Nos. conform with each other for between outdoor and between indoor units. However, they will work properly if different polarities are connected. (Connect (A) and (A), (B)and (B).) Do not strand or run the remote control cord with power line, electric line, etc. The total length of the signal wires Should be 1000m or less. Recommended signal wire list Name No. Symbol 1 Vinyl cabtire round cord VCTF double-core 0.75 to 2 mm2 2 Vinyl cabtire round cable VCT double-core 0.75 to 2 mm2 3 Control vinyl insulated, vinyl sheathed cable CVV double-core 0.75 to 2 mm2 4 Shielding wire MVVS double-core 0.75 to 2 mm2 When No. 4 shielding wire is used, always ground the single wire side of the shielding wire . In addition, using the shielding wire is helpful to prevent the incorrect connection between 5V DC and 220/240V or 380/415V AC because the discrimination from the power supply wire is clear. (3) Wiring system Diagram Power source (outdoor unit side) 3-Phase 380/415V 50Hz Earth leakage breaker Outdoor Unit Circult breaker Signal wire (between outdoor and indoor unit) Power source wire [Individual flow divide controller accessory wire (2m)] Earth Individual flow divide controllor Individual flow divide controller accessory wire (2m) Relay kit (Individual flow divide controller accessory) Signal wire (between indoor units) Circult breaker Earth leakage breaker Indoor Unit Signal wire [Relay kit accessory (2m)] 1 2 3 4 5 6 7 8 Power source (indoor unit side) 1-Phase 220/240V 50Hz Remote controller Remote controller wire 1059 FDC-HKXR Outdoor/Indoor units connection procedures Outdoor unit AB Individual flow divide controllor Power source (indoor unit side) Power source wire [Individual flow divide controller accessory wire (2m) To next units by turn L • N C N U Individual flow divide controller accessory wire (2m) Cn Cn B T4 Cn T L • N AB XYZ C N U Cn Cn B T4 1 Relay kit (Individual flow divide controller acessory) Cn T Indoor unit 2 XYZ Signal wire (between indoor unit) AB XYZ Remote controller wire XYZ Remote controller Signal wire [Relay kit accessory (2m)] Signal wire Do not connect high voltage wire 380/415V to signal wires, as these wires are DC 5V. Signal wires should be connected so that the terminal Nos. conform with each other for between outdoor and between indoor units. However, they will work properly if different polarities are connected. (Connect (A) and (A), (B) and (B).) Sensor inlet Signal wire inlet Outdoor control box Signal wire (Between outdoor and indoor units) Be sure to let the signal wire get in through the signal wire inlet. (4) Indoor and outdoor signal wiring (a) If only one Outdoor unit is used Outdoor signal teminal block A B Double cores 0.75 ~ 2 mm2 Total length of signal wires: 1000 m or less A B A B A B Indoor signal terminal block Notes (1) The indoor and outdoor signal wiring are without polarity B B B B A A A A Either of the above wiring is correct. (2) For connection to the terminal block, use as M3.5 (5/32) round eye-let terminal is shown below. 7 mm or less 1060 FDC-HKXR (b) If plural outdoor units are used 1) A maximum of 48 indoor units can be connected by using the crossover wiring method, with 2 wires for each side of the outdoor and indoor units. Outdoor unit Outdoor unit AB AB Outdoor unit Outdoor unit AB AB Double cores 0.75 ~ 2 mm2 Total length of signal wires: 1000 m or less AB AB Indoor unit AB Indoor unit AB Indoor unit Indoor unit 2) Indoor/outdoor wiring method for multiple floors. Outdoor unit Outdoor unit Outdoor unit Outdoor unit Double cores 0.75 ~ 2 mm2 Total length of signal wires: 1000 m or less Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit 3) Loop wiring is inhibited Outdoor unit Outdoor unit Outdoor unit Outdoor unit Loop wiring of signal wires is inhibiteed Wiring at the Portion indicated by a dotted line is inhibited. (No) Indoor unit Indoor unit Indoor unit Indoor unit (5) Remote controller wiring (a) Wiring for controlling only one indoor unit. X Y Z Red White Black X Y Z Red White Black Indoor unit terminal blocks Note (1) Cables for the remote controller have polarity. Be sure to connect terminal blocks with the same numbers. If mis wiring occurs, E1 is displayed and disables the unit from operating. Remote controller terminal blocks 1061 FDC-HKXR (b) When controlling plural units. 1) Use the same procedure shown in the drawing above for the wiring of the power supply, both indoor and outdoor units and remote controller When the wiring length for the remote controller exceeds 100 m, use the wiring procedure shown in the drawing below. 2) Connect each of the indoor units for group controlling (3 cables) a) Connect the cables to the terminal blocks of X, Y, and Z for the indoor unit remote controller. Since the cables have polarity, be sure to connect them to terminal blocks with the same numbers. b) Use cables of more than 0.5 mm2 (Flexible and easily moved) c) The total length of cables for crossover connection and the remote controller should be less than 600 m. Allowable range of wire thickness and length Standard Within 0.3mm2 × Within 100m 0.5mm2 × Within 200m 0.75mm2 × Within 300m 1.25mm2 × Within 400m 2mm2 × Within 600m 3) When there is more than one outdoor unit, they can be controlled by one remote controller. 4) One remote controller is capable of controlling up to 16 units in group. Note (1) Use shielded cables, when wiring in parallel with cables for other power supply or when there is a possibility of being affected by outer noise such as noise from a high-frequency unit. Outdoor unit Unit address A B No.01 Outdoor unit Unit address A B No.02 Indoor unit (Outdoor unit address No.01) (Indoor unit address No.00) A B Indoor unit (Outdoor unit address No.02) (Indoor unit address No.03) Indoor unit (Outdoor unit address No.01) (Indoor unit address No.01) A B Indoor unit (Outdoor unit address No.02) (Indoor unit address No.04) Indoor unit (Outdoor unit address No.01) (Indoor unit address No.02) A B A B A B Indoor unit (Outdoor unit address No.02) (Indoor unit address No.05 A B Remote controller (c) Settings for main and secondary units when multiple remote controllers are used. Up to two remote controllers can be used for each indoor Remote control signal wire (has unit (or each group of indoor units). Indoor unit polarity) X Y Z 1) There are two methods for arranging this. One Match X Y and Z and connect. method is to take a remote control connection wire (3-strand) from the indoor unit for the secondary remote control. The other method is to use a jumper wire from the main remote control. 2) Set the remote control switch for the secondary unit (SW4) to X Y Z X Y Z secondary unit. (It was set to main unit a the factory.) Note (1) The remote controller sensor setting is only enabled on the main remote controller. Be sure to position the main remote controller in a location where it can detect the room temperature. 1062 Remote control SW4 Main Remote control SW4 Secondary FDC-HKXR (6) Setting of unit address Addresses can be set either with the automatic address setting, remote control address setting or manual address setting depending on the combinations of address switches (see table) of the indoor and outdoor units. Operate the address switches before turning power on. Indoor unit Outdoor unit Address setting method Outdoor No. Outdoor No. Indoor No. Auto address 49 49 49 Remote control address 00 ~ 47 49 49 Manual address 00 ~ 47 00 ~ 47 00 ~ 47 At the shipment from factory, outdoor Nos. of the outdoor unit are set at 49, both the output and indoor Nos. of the indoor units are set at 49 and the setting method is set for the automatic addressing. Address No. setting Set the setting SW1 - 4 on the indoor PCB and the setting SW1 and 2 on the outdoor PCB as listed below. On indoor PCB On outdoor PCB SW1, 2 (blue) For setting of indoor No. (orders of 10 and 1) SW3, 4 (green) For setting of outdoor No. (orders of 10 and 1) SW1, 2 (green) For setting of outdoor No. (orders of 10 and 1) SW2 (SW4) Order of 1 0 1 2 3 4 Order of 10 SW1(SW3) SW1 (SW3) order of 10 Order of 10 SW2(SW4) 0 1 9 7 8 2 3 Insert the tip of flat head (precision) screwdriver here and point the arrow at a desired No. 9 0 1 2 3 4 5 6 7 8 0 00 01 02 03 04 05 06 07 08 09 1 10 11 12 13 14 15 16 17 18 19 2 20 21 22 23 24 25 26 27 28 29 3 30 31 32 33 34 35 36 37 38 39 4 40 41 42 43 44 45 46 47 48 49 Use 48 and 49 for setting the auto or remote control address. 4 5 6 Order of 1 Notes (1) Outdoor No. is provided on the outdoor and indoor PCB's and indicates which outdoor unit is connected with which indoor unit via a refrigerant pipe. Indoor and outdoor units connected with a refrigerant pipe must have the same No. (2) Indoor No. is used to identify a particular indoor unit. The No. should never be duplicated. (a) Auto address setting This setting is used when wiring on the basis of outdoor unit. Outdoor unit No. 49 AB AB Indoor unit AB Indoor unit AB Indoor unit Remote controller Remote controller Remote controller AB Indoor unit Wires cannot be connected across different refrigerant lines. 1063 FDC-HKXR 1) 2) 3) Set the address switch of outdoor unit at 49. (This is set at 49 at shipment from factory.) Set the address switch of indoor unit at 49. (This is set at 49 at shipment from factory) Turn power on for the indoor and outdoor units. Addresses are set automatically. (No. in a range of 0 - 11.) For the auto address setting, power must be ON for both the indoor and outdoor units. If power is supplied to the indoor unit only, "Outdoor No." is indicated on the remote controller. In such occasion, turn power ON also for the outdoor unit. 4) No. will be set within approx. 1 minute after turning power on. 5) If you press the inspection switch of the remote controller after setting the No., the address of indoor unit will be displayed. The outdoor unit No. 49 will also be displayed. 6) Auto address setting is allowed also when controlling plural number of units with single remote controller. However, the connection cannot be made across different refrigeration lines. Information 1) Once addresses are set, they are retained on the microcomputer even after turning power off. 2) Even if the wiring is arranged on the basis of outdoor units, (2) remote control address setting and (3) manual address setting can be used. Erasing of addresses set with the automatic address setting On the remote controller, press the "Fan speed" switch while holding down both the switches "Check" and "Timer". Memory of address is erased. If the power supply to the indoor and outdoor units is turned off later, the system returns to the state of no address setting. Then one of the three address setting methods can be selected by changing combinations of the address switches. (b) Setting of remote control addresses This setting is used when connecting a plural number of indoor and outdoor units with the super link. This is applicable when using single remote controller. Figures in ( ) indicate address No. by the remote control ine "- - -" shows the refrigerant piping. Address No. by the remote control Outdoor unit Outdoor unit No.00 No.01 AB Indoor unit Indoor unit (Outdoor No. 00) (Indoor No. 00) (Outdoor No. 01) (Indoor No. 03) A AB Indoor unit Indoor unit (Outdoor No. 00) (Indoor No. 01) A (Outdoor No. 01) (Indoor No. 04) B 1064 AB Remote controller Remote controller Indoor unit Indoor unit (Outdoor No. 00) (Indoor No. 02) (Outdoor No. 01) (Indoor No. 05) Remote controller B Remote controller Remote controller 1) 2) 3) 4) AB AB AB Remote controller Set the address of outdoor unit with a number in a range of 0 - 47 avoiding duplication with any other outdoor unit. Leave intact the address switch on the indoor unit PCB at 49 as set at the shipment from factory. Turn power on. Then you can proceed the remote control address setting. Set the outdoor No. corresponding to each indoor unit, using the remote controller. Set next the indoor No. of indoor unit in a range or 0 - 47 avoiding duplication with any other unit connected in the group. FDC-HKXR Detail of setting from the remote controller 1) If the power switch is turned on, the outdoor No. on the display flashes, and "--" on the return air temperature display section and "U--" on the time display section are lit. If power is not supplied to the outdoor unit, the outdoor No. only lights and you cannot set the address. In such occasion, to turn power on also for the outdoor unit. 2) Indoor No. increases 0, 1, 2, ... and up at each push on the room temperature setting ▲ switch. Press the room temperature setting ▼ to reduce the outdoor No. 0, 47, 46, 45 ... and down. Stop to press the switches when a desired No. is indicated. 3) Press the Set switch so that the outdoor unit display changes from flashing to firm lighting and the outdoor No. is set. Simultaneously, "U" indicating the indoor unit No. starts to flash. 4) Set the indoor No. in the same way with the room temperature setting switches ▲ and ▼. 5) After completing the setting, press the Set switch so that the "U" display changes from flashing to firm lighting and the figures of outdoor No. and indoor No. on display start to flash. 6) Confirming the outdoor No. and indoor No. being correct, press the Set switch again. If you like to change these Nos., press the "Check" switch so that it returns to the state of the step 2) and you can resume the address setting. 7) This is all for the address setting. The address display will go off 5 seconds later. Note (1) Once the addresses are set, they are retained on the microcomputer even after turning power off. If you need to change the address, proceed as follows. Change of address Hold down the "Check" switch on the remote controller for more than 5 seconds. Outdoor No. on display flashes and you can set new addresses. Set the outdoor and indoor address Nos. same as described above. New addresses can be set. Erasing the addresses set by the remote control address setting Holding down both the switches "Check" and "Timer", press the "Fan speed" switch. Addresses in the memory are erased. Turn power off on the indoor and outdoor units so that it returns to the no address setting condition and you can set the addresses with one of the three methods of address setting by changing combinations of the address switches. (c) Manual address setting This setting is used when connecting plural number of outdoor and indoor units with the super link, and is applicable when controlling with more than one remote controller. (You can use only one remote controller of course.) Turn power off before operating the address switches. Change of address is disabled when power is supplied. Line "- - -" indicates the refrigerant piping. Figure in the figure indicates the address number determined with the address switch. Address No. by address switch Outdoor unit Outdoor unit No.01 No.02 2) 3) AB Indoor unit Indoor unit (Outdoor No. 01) (Indoor No. 00) (Outdoor No. 02) (Indoor No. 04) AB AB Indoor unit Indoor unit (Outdoor No. 01) (Indoor No. 02) (Outdoor No. 02) (Indoor No. 05) AB AB Indoor unit Indoor unit (Outdoor No. 01) (Indoor No. 03) (Outdoor No. 02) (Indoor No. 06) Remote controller 1) AB AB AB Remote controller Using the address switch (green) on the outdoor unit PCB, set the address of the outdoor unit in a range of 00 - 47 avoiding duplication with any other outdoor unit. Using the address switch (green) on the indoor unit PCB, set the outdoor No. at the same No. as the outdoor unit which is connected with a refrigerant pipe. Using the address switch (blue), set the indoor No. of indoor unit in a range of 00 - 47 avoiding duplication with any other unit on the connection. 1065 FDC-HKXR 20.5.6 Test run (1) Before starting operation (a) Measure resistances between the electrical parts terminal block and grounded area using a 500 V Megger, insulator. Resistance must be higher than 1 MΩ. (b) Confirm whether the power source breaker (main switch) of the unit has been turned on for over 12 hours to energize the crankcase heater in advance of operation. (c) Make sure that the compressor bottom has been warmed. (d) Be sure to fully open the service valves (on both the gas and liquid sides) of the outdoor unit. If being operated without opening, the valve may be got out of order. Note (1) When the service valve is closed, be sure to check that evacuation is completed or a refrigerant is charged. (2) Test run (a) If it is impossible, a test run of indoor units can be conducted by using the switches No. 4 and No. 5 of [SW-3] on the outdoor unit circuit board irrespective of ON/OFF conditions of CnS and the remote controller. No. 4 of [Sw3] • All connected indoor units operate when the switch is set to ON. Test run • Indoor units request the maximum frequency and the outdoor unit operates with the maximum frequency shown in the table below according to requests from indoor units. Normal • Select cooling or heating according to input to No. 5 of [SW3]. No. 5 of [Sw3] • Turn this on makes it possible to conduct cooling operation when [SW3] No. 4 is turned on. • When the switch is set to OFF, these units can be operated with the remote controller or by external input. • Turning this off makes it possible to conduct heating operation when [SW3]’s No. 4 is turned off. [Remark] This operation has priority over other option commands with the center console. At the time of trial operation, the maximum frequencies are follows. Protective devices are effectively controlled, and frequencies are controlled to become smaller. Models Maximum frequency for operation (Hz) (b) FDCP2001HKXRE2 FDCP2501HKXRE2 95 95 The frequency for operation can be monitored with yellow LEDs on the indoor unit circuit board. Relations between LED lighting condition and frequency are as follows. Notes (1) Inverter frequency monitor mark: Flashing mark: Stays OFF (2) Relation between LED3 ~5 LED3 and operation frequency LED4 • LED3 .......... 40 Hz LED5 • LED4 .......... 20 Hz Operation 0 ~ 35 frequency 35 ~ 45 45 ~ 55 55 ~ 65 65 ~ 75 75 ~ 85 85 ~ 95 95 ~ 110 • LED5 .......... 10 Hz • Operation frequency = CAUTION: After end of a test run order, set No. 4 of [SW3] to OFF Frequency indicated by LED3 ~ 5 + 25 1066 FDC-HKXR (3) Cooling test run operation (Cooling test run can be performed in winter.) (a) Operation method ● In the normal cooling mode, hold down the “Temperature Set” switch while pushing the “Set” switch. ● Setting temperature is changed at 5˚C and the cooling test run is operated for 30 minutes. It stops after 30 minutes. (b) During cooling test run operation ● If ON/OFF switch is pressed or a mode other than the cooling is selected by the “Mode” switch, the cooling test run operation is released or returns to the specified operation mode. ● If the “Temperature set” switch is pressed, the setting temperature changed at 18˚C and the cooling test run operation is released but the cooling operation continues. ● It is effective when any switches other than the above are pressed. (c) During the cooling test run operation, the setting temperature changed at 5°C but any other control and protective functions are operable just like in the normal operation. ● If any error occurs, the location of error is indicated on the remote controller display or with the condition of flashing of inspection lamp (red) on the main unit controller. Remove the cause of trouble before starting operation again. (4) Delivery (a) Explain how to operate the indoor unit to your customer according to the accessory owner’s manual. (b) Persuade the customer not to turn off the power switch even if the unit is not used for along time. The air conditioner can start operation any time when your customer want to heating or cooling his room. (The bottom of the compressor is heated with the crank case heater, and compressor troubles can be prevented when the cooling or heating season sets in.) 1067 FDC-HKXR 20.6. MAINTENANCE DATA 20.6.1 Diagnosis of Microcomputer circuit (1) Confirmation of the error code on the remote controller (by pressing the inspection switch) and the inspection display and normal display lamps on PCBs of indoor/ outdoor units The microcomputer detects errors on electrical components, whitch include the microcomputer itself, errors on the power supply line and errors (overload, etc.) on the refrigerant circuit and the location of trouble is displayed (with the combination of error symbols of remote controller, normal (green) and inspection (red) display LED on PCBs of indoor/outdoor units.) When any error occurs, check first the inspection display. It will guide you to the trouble point and assist you to complete the repair work quikly. Error code of the remote controller is recorded on the microcomputer after the trouble has been reset automatically so that, if you press the inspection switch of remote controller, the error code and the number of unit in trouble are displayed for 10 sec., The inspection display lamp on the indoor/outdoor unit PCB keeps flashing (glowing) even after the trouble was reset automatically. Inspection lamp on the indoor unit PCB is turned off if the remote controller is reset. 1) Inspection / normal: List of power display Remote controller Section Display section LCD At power ON: Displays always the return air temperature and Center/ Remote. Error code LCD At error: Displays E1 ~ E46 or blank depending on the kings of error. Indoor/outdoor unit Normal display Error display Normaly display Inverters Contents of display Power supply display Inspection display 1068 Display Error display Red-LED Green-LED Red-LED Green-LD1 At error: Flash continuously (indicates the occurrence of error). At power ON (normal): Flash continuously. At error: Off or continuous glowing or irregular illumination. At error: Flash 1 ~ 3 times/ 5 sec for indoor unit depending on the kinds of error, continuous flash, irregular illumination or off. At error: Flash 1 ~ 9 times/ 10 sec for outdoor unit. depending on the kinds of error, continuous flash, irregular illumination or off. At power ON (normal): Flash continuously At error: off or continuous glowing or irregular illumination. Red-LD2 At error: Lights when the power transistor overheats (for 3 minutes or more). Red-LD3 At error: Lights upon occurrence of a current-cut (held for 3 minutes). Red-LD4 At error: Lights when a transmisson error occurs between outdoor unit inverters. 1 time flash Stays OFF 2 time flash Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing E11 E12 Keeps flashing 1 time flash Keeps flashing E10 E28 Stays OFF Keeps flashing E9 Stays OFF Stays OFF 1 time flash 1 time flash Keeps flashing 1 time flash Keeps flashing 2 time flash E7 Keeps flashing 2 time flash 3 time flash Keeps flashing Keeps flashing 32-sec time flash Stay OFF or Lights continuously 2 time flash Stays OFF Keeps flashing Keeps flashing 3 time flash Stays OFF Stays OFF Keeps flashing Keeps flashing Stays OFF Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Stay OFF or Lights continuously Keeps flashing Keeps flashing Stays OFF Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Stays OFF Lights continuously Stays OFF Keeps flashing Lights continuously Red Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF 32-sec time flash 6 time flash Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stay OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Outdoor unit LED Green Indoor unit LED Red Green E6 E5 E3 E2 E1 No-indication Remote controller error code Remote controller thermistor failure Outdoor No, 0 ~ 47 48, 49 Indoor No, 48, 49 0 ~ 47 Address No. combination error or addressing is performed with the following combinations. Remote controller addresses have been set while more than one units of remote controller are connected. When multi-unit control by remote controller is performed, the number of units is over (more than 17 units). Two remote controllers are provided for one controller is performed. The float SW operates (with FS only). Drain up kit wiring fault. Indoor unit return air thermistor failure Indoor unit heat exchanger thermistor failure Outdoor unit microcomputer failure Indoor/outdoor transmission error. Wire A and B swapping after power ON. The corresponding outdoor unit address No is not found. (Detected only during opreation) Indoor/outdoor signal line wire breaking Indoor unit PCB fault. Outdoor unit power supply OFF (detected only during operation) No. duplication at remote controller addressing No. duplication at indoor unit addressing. More than 49 indoor unit are connected. The PAC remote controller is connected to the KX. The remote controller wire Y is open. The remote controller wires X and Y are reversely connected. (The LED flash twice a second.) Two remote controllers are provided.* For wire breaking at power ON,the LED is OFF. Indoor unit PCB fault The remote controller wires are connected to A and B on the terminal block. The indoor/outdoor signal wire are connected in loop form. The indoor unit microcomputer runs away. Remote controller wires X and Y are reversely connected.* For wire breaking at power ON, the LED is OFF. Remote controller wire is open. (X wire breaking: A beep is produced and no indication is made. Z wire breaking: No beep and no indication) The remote controller wires Y and Z are reversely connected. (32-sec time flash) Power OFF, L3 phase wiring is open, power source failure Indoor unit PCB fault, CPU runaway Normal Cause 2) Check Indicator Table Whether a failure exists or not on the indoor unit and outdoor unit can be known by the contents of remote controller error code, indoor / outdoor unit green LED (power pilot lamp and microcomputer normality pilot lamp) or red LED (check pilot lamp). FDC-HKXR 1069 Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Stays OFF Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing E31 E34 E36 E37 E38 E39 E40 1070 E41 E42 E43 E45 E46 Stays OFF 7 time flash 9 time flash 1 time flash 4 time flash 3 time flash Keeps flashing Keeps flashing Keeps flashing 5 time flash 2 time flash 8 time flash Red Automatic address setting and remote controller address setting or manual address setting coexists in the same network. The number of connectable units is exceeded. Transmission error between inverter and outdoor unit PCB Abnormal current cut of compressor (CM1) Power transistor overheat 63H1 operation Discharge temperature thermistor failure Outside temperature sensor failure Outdoor unit heat exchanger thermistor failure Discharge temperature abnormality. 52C secondary side L3-phase wiring is open. Inverters error. Outdoor unit No. duplication. Outdoor unit address No. is not set for super lynk wiring. Outdoor unit address No. is changed in the power ON status. Cause 1. 2. 4. Outdoor No. 3. Outdoor No. Outdoor No. 5. 6. Then, remote controller address setting can be performed. Turn off the indoor and outdoor power supplies, and set the address switch on the PCB of the outdoor unit to any of 0 to 47. After setting, turn on the indoor and outdoor power supplies. The above shows the case of remote controller address setting. There is a unit for which the address switch on the PCB of the outdoor unit connected on the same network is set at "49". (2) When the following displays (6 patterns) coexist: at once by pressing the operation switch. abnormality occurs on only a unit. In this case, the remote controller for the unit in which a drain abnormality occurred does not indicate the failure but stops. It is also stopped Notes (1) Even if an abnormality occurs in a part of indoor units, outdoor units continue to operate. However, in case of a drain abnormality, the outdoor units stop even when an Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Keeps flashing Green Red Outdoor unit LED Green Indoor unit LED Remote controller error code FDC-HKXR FDC-HKXR 3) Display sequence of error, inspection display lamp a) One kind error Display corresponding to the error is shown. b) More than one errors. Section Error code of remote controller Display section • Displays the error of higher prority (When plural errors are persisting.) Inspection LED(red) of indoor unit PCB Inspection LED (red) of outdoor unit PCB •••••• • Displays the present errors. (When a new error has occurred after the former error was reset.) c) Timing of error detection • Indoor unit side. Error detail Error code Timing of error detection Transmission error of remote controller indoor unit When the transmission error continuously for 2 min. CPU is out of control Resetting was performed at the rate of 1 time per second. An abnormal stop occurred 120 times running. Transmission error between indoor/outdoor units A check was made once every 20 second. An abnormal stop occurred 7 time running. Broken wire of heat exchanger thermistor After a compressor ON command, this failure was detected for 5 second in the period of 2 minutes to 2 minutes and 20 seconds. Broken wire of indoor unit return air thermistor This failure was detected continuously for 5 seconds. Drain error(float switch motion) At the thermostat ON state, an abnormal stop occurred immediately after the float switch operated. - At a stop or the thermostat OFF state, the condensate motor was turned on for 3 minutes after the float switch operated. After that, an abnormal stop occurred when the float switch operated in 10 seconds. 1071 FDC-HKXR • Outdoor unit side Error detail Error code Timing of error detection 52C secondary side L3-phase wiring is open. An abnormal stop occurs when the L3-phase voltage is 0 V for 5 seconds running. (Detected with 52C ON only) Discharge temperature abnormality A stop occurs when this abnormality occurs for 2 seconds running at 130°C After a stop for 3 minutes, an recovery is automatically made. An abnormal stop occurs when this abnormality occurs twice for 60 minutes. (The abnormal state is held for 45 minutes.) Broken wire of heat exchanger thermister Broken wire of outdoor temperature thermister This failure is detected when it occurs for 5 seconds running in the period of 2 minutes to 2 minutes and 20 seconds with the compressor ON. An abnormal stop occurs when this failure occurs 3 times for 40 minutes. Broken wire of discharge thermister This failure is detected when it occurs for 5 seconds running in the period of 10 minutes to 10 minutes and 20 seconds with the compressor ON. An abnormal stop occurs when this failure occurs 3 times for 40 minutes. Hight pressure cut An abnormal stop occurs when this abnormality occurs 2 times for 40 minutes. Power transistor overheat A stop occurs at 90°C or more. After 3 minutes, a recovery was automatically made at 83°C or less. Abnormal stop occurs when this abnormality occurs 2 times for 2 hours. Current cut An abnormal stop occurs when this abnormality occurs 4 times for 15 minutes. Excessive number of outdoor units This error is detected when the number of connectable units is set over the specified value at remote control addressing. Transmission error between inverter and outdoor unit PCB When an transmission error continues for 10 seconds, the 52C is turned off. With a delay of 3 minutes, a recovery is automatically made. An abnormal stop occurs when this error occurs 4 times for 15 minutes. d) Recording and reset of error Error display Error code Indoor unit lamp (red) Reset Memory • Saves in memory the mode(1) of • Stop the unit operation by pressing the ON/OFF switch of higher priority remote controller. • Operation can be started again if the error has been reset.(2) inspection • Cannot save in memory Outdoor unit inspection • Saves in memory the mode(1) of higher priority lamp (red) Notes (1) Priority is in the order of E1 > ... > E10 > ... > 45. (2) Reset is disabled for 45 min. at the error of outdoor unit or compressor overcurrent or the discharge gas temperature error. e) Reset of error code in memory (when the error has been reset.) Indoor unit: Press the Timer switch and the Stop switch while the Inspection switch of wired remote controller is held down or detach the power supply connector (CnW2) of indoor unit PCB and connect again or turn OFF the power. Outdoor unit: Detach the power supply connector (CNA2) of outdoor unit PCB and connect again or turn OFF the power supply or turn on and off the SW3-1. (2) Procedures of trouble diagnosis When any error occurs, inspect in following sequence. Detailed explanation on each step is given later in this text. Error Power supply check (indoor/outdoor unit) Replacement or repair of defective parts Test run/adjustment Check of inspection display [Indoor/outdoor unit PCB, remote controller or Indication board] Check of unit controller Power supply reset (1) Check of inspection display [Indoor/outdoor unit PCB, remote controller or Indication board] Note (1) It means the operation to turn off the power and back on again more than 1 min. later in order to reset the malfunction of microcomputer due to the effect of power supply conditions or accidental noise. 1072 FDC-HKXR (a) Diagnosis by the power supply reset When any error occurs, reset the power supply as described below to see if it is the result of accidental noise, etc. Check at the indoor unit side. Error Are the return air temperature and Center/ Remote displayed on the remote controller? YES Is any error code display? NO NO YES Check the error code displayed Power switch OFF Power supply line error ON/OFF switch OFF Does the error code disappear? NO Microcomputer out of control YES Turn off the wiring breaker (power supply) and back on again 1min. later. (Power supply reset) ON/OFF switch OFF Does start operation with display of cooling degree: Hi, thermostat: 23°C? NO Power supply line error See page 1077 YES Does the error repeat NO Cause is accidental (noise, etc.) and the unit is normal. YES Check of error code Errors due to external noise, etc. Error code may be displayed or the error may not be displayed normally even if the controller is normal because of external noise source(1) or joined or parallel arrangement of power cables and signal wires. It is because the wire of remote controller, wired remote controller signal wires for multiple units or the network signal wires may be influenced by external noises whitch are judged as signals by the microcomputer whitch reacts mistakenly. When there is any noise source, it is necessary to the shield wire for the remote controller and signal wires. Note (1) High frequency medical machine, rectifier motor application device, thyristor, broadcast transmission tower, power transmission line, power line of electric train, automatic door motor, elevator (voltage drop), wireless telephone, high voltage power distribution line, computer, personal compouter and their cables. There do not necessarily always cause problems but they can be a source of electrical noise. 1073 FDC-HKXR (2) Reference Effect of noise • When noises inturude into the remote controller. Abnormal or irregular display such as the flashing of irrelevant display (lamp) (for example, LEDs of cooling and heating illuminated simultaneously or the like) is observed even if the remote controller is not operated or the remote controller and, as the result, the operation of units may be disabled or similar abnormal phenomenons are observed. • When noises intruded into the microcomputer of printed circuit board; State of operation becomes abnormal such as the units perform irregular operation while the remote controller is not operated, the operation cannot be stopped with the remote controller, etc. Electro magnetic noise prevention(example) • Cover the entire surface of control box or the inside of unit cover with the cover foil or cover the enitre unit with a wire net. Use the shield or twist pair wires Interisified shielding of control section Signal wire Make a positive ground Remote controller wire (Indoor unit) Outdoor unit (Indoor unit) l2 Shut off electrically the noise source or put it in a shield room. Beware of noises transmitted via air. Cutting machine welder High frequency l1 Put in a steel case Remote controller Separate from cutting machine as for as possible. This is very effective because the effect of noise is in inverse proportion to 1.5 times of distance. •Insert in a steel pipe to shield. Power cable Unless it has a sufficient current capacity, mini split current drops momentarily at the start/stop of cutting machine. Distribution board Avoid supply from the same distribution board to prevent troubles by the power source propagation. Install the line filter at the power supply of cutting machine of mini split (Positive grounding is necessary.) (b) Eroor diagnosis procedures at the indoor unit side The error diagnosis for indoor units is the same as for the Multi KX Series. For details, please refer to the section for the KX Series found on pages 910 to 917. (c) Error diagnosis procedures at the outdoor unit side At the error diagnosis related to the outdoor unit, check at first the error code of remote controller and the illumination patterns of norma l and inspection display lamps in the same manner as the case of indoor unit. Then estimate the outline, the cause and the location of error based on the pattern and proceed to the inspection and repair. Since the self diagnosis function by means of the microcomputers of indoor/outdoor units provide the judgement of error of microcomputers them selves irregularity power supply line, overload, etc. caused by the installation space, inadequate volume of refrigerant etc., the location and cause of trouble will be discovered without difficulty. In addition, the display lamps error code of indoor/outdoor units is kept flashing, (except when the power supply is interrupted)after the irregularity is automatically recovered to give irregularity information to the service presonnel. If any mode of higher priority than the error retained in memory occurs after the reset of error, it is switched to that mode and saved in the memory. (i) Replacement parts assembly related to the outdoor unit PCB Outdoor unit PCB, outdoor unit inverter PCB, power transistor module, diode module, capacitor, reactor, noise filter, thermistor, 1074 FDC-HKXR (ii) Parts layout on the outdoor unit PCB Operation output 18 17 16 19 20 23 • Function of DIP switch CNH 2 Name CNY(White) 2 CNI(White) L6 7 2 L9 ON IC4 SW2 CNE(White) X1 9 83 ON External input SW3-2 Outdoor unit number address setting switch (SW: Order of 1) OFF ON SW3-3 OFF Outdoor unit number address setting switch (SW: Order of 10) Name ON Checker 6 IC3 SW Test Forced Heat Cool Trial Snowing Defrosting Reset J3 J2 J1 OFF L7 L8 L10 IC8 IC5 C5 R17 R18 IC10 + + 52×4 SK7 R15 R16 R9 PC5 IC13 SW1 ON SW3-1 Failare SW3-4 IC7 IC9 C8 52×7 OFF SK8 ON SW3-5 2 CNB(Red) 2 CND(Yellow) 2 CNU(Blue) 2 CNC(Black) C4 ZNR + IC2 CNA1 −+ ∼ − + + DS217V 3 IC14 C1 2 ZD3 ZD2 ZD4 ZD5 3 CT 8V1 − C3 200V DS1 DS3 + VR1 IC15 IGø ICI øGI OFF Reference page Trial operation 1042 Regular operation Cooling trail operation 1042 Heating trail operation OFF Regulat operation ON Test mode OFF Regular operation • Function of jumper wires Model Serial 4 CNA2 PCB power supply connector (Secondary side) PCB power supply connector (Primary side) Function Compulsory operation Thermistor SW3-7 Function Reference page Check LED reset Normal operation Easy to start defrosting 1037 Normal operation Measure against snow 1039 Normal operation ON SW3-6 CNX(White) IC6 C9 R19 C10 52×1 SK1 + R20 C6 + C12 4 + C13 C11 52×2 ZD1 52×3 SK3 + SK2 5 + C23 C19 C18 IC12 10 9 C20 R8 PC4 R10 R5 PC3 R7 R3 PC2 R6 R2 R1 PC1 R4 C17 ~ S OUT GND 52×14 SK4 8 ~ IC11 C15 6 52×13 SK6 7 ~ 52×12 SK5 11 ~ 52×11 SK10 12 C16 ~ SK11 13 52×9 SK13 52×10 5V CNS(Black) SK9 52×8 12V 15 J1 J2 J3 FDCP2001 With With None(1) FDCP2501 With With None(1) Note (1) “None” means that jumper wire is not provided on the PCB or the connection is cut. • Replacement procedure of indoor unit microcomputer printed circuit board Microcomputer printed circuit board can replaced with following procedure. 1) Confirm the parts numbers. (Refer to the following parts layout drawing for the location of pats number.) Model Parts No. FDCP2001, 2501HKXRE2 PCB505A012L Notes (1) Inverter frequency monitor (2) Relation between LED3~5 LED3 and operation frequency • LED3......40Hz LED4 • LED4......20Hz LED5 Operation frequency 0~35 mark: Flashing mark: Stays OFF • LED5......10Hz 35~45 45~55 55~65 65~75 75~85 85~95 95~100 • Operation frequency = Frequency indicated by LED3~5 + 25 1075 FDC-HKXR (iii) Check procedure depending on indication lamps (For the outdoor unit) 1 [Error on the outdoor unit signal line] Error display: (Detected during operation only) Indoor unit Red LED 2 time flash Green LED Keeps flashing Outdoor unit Red LED Stays OFF Green LED Stays OFF Power supply checked between R~N or terminal block YES Is there AC 17V checked between CNA2 (blue) ~ (blue) and AC 8V between (red) ~ (red) of outdoor unit transfomer? YES Power supply reset Is it YES Normalized? NO NO Power not supplied. Power supply wiring error→Repair. NO •Blown fuse (3.15A) →Replacement • Defective transformer→ Replcement • Broken power supply wire in the unit Repair Defective outdoor unit PCB Outdoor unit Red LED Green LED Stays OFF Is the pairing of Indoor/outdoor units OK? Keeps flashing NO(1) Change of unit number setting Note (1) NO outdoor unit corresponding to the indoor unit. 1076 YES Is the connection of network signal wires good? NO Repair the door connection, broken wire of network signal wires. Unit is normal FDC-HKXR 2 [Outdoor unit signal line error, power supply error] Error display: Indoor unit Red LED 2time flash Green LED Keeps flashing Outdoor unit Red LED Stays OFF Green LED Stays OFF (1) Did turn off the power of outdoor unit during operation? YES Power supply ON NO(1) • Blown fuse? • Broken or loose wire at L1, L2 or N Phase? • Was not there the power failure? Note (1) This case is limited to the separate power supplies to indoor/outdoor units. (Combination of (indoor unit) red LED 2 time flash and (outdoor unit) green LED stays off means that the power supply to the outdoor unit has been interrupted during operation.) Outdoor unit Red LED Stays OFF or keeps flashing Green LED Stays OFF or Lights continuously Power supply reset Is it normalized? Malfunction due to noise, etc. (Out of control CPU of outdoor unit due to noise during power on) YES NO Defective outdoor unit PCB→Replacement (Defective network communication circuit) (1) Outdoor unit Red LED Green LED Stays OFF Keeps flashing Signal wire poor connection at outdoor unit? YES Repair NO (2) Signal wire poor contact between indoor/ outdoor units? YES Repair NO Power supply reset Notes (1) Check for poor connection (Iooseness, misconnection) at outdoor unit terminal block and broken signal wires between outdoor units. (2) Check the poor connection or broken signal wires between indoor/outdoor units. Is it normalized YES Unit is normal. (Malfunction by accidental noise) Defective outdoor unit PCB→Replacement (Defective network communication circuit) 1077 FDC-HKXR 3 [Duplicated unit No. of outdoor units] Error display: Indoor unit Stays OFF Keeps flashing Red LED Green LED Red LED Green LED Is the unit No. duplicated on outdoor units? YES Outdoor unit 8 time flash Keeps flashing Correction NO Defective outdoor unit PCB Replacement (Defective unit No. read circuit) 4 [Open phase at L3 phase of 52C secondary side (CM2)] Error display: Indoor unit Stays OFF Keeps flashing Red LED Green LED Note (1) When the PCB is defective, the flash patterns of outdoor unit red LED, green LED may become irregular. Red LED Green LED Outdoor unit 2 time flash (1) Keeps flashing (1) YES 52C secondary side L3 phase open? Notes (1) When voltage is detected at 52C primary side but not at the secondary side, check also 52C (broken coil, poor contact). (2) When voltage is detected at 52C primary side L3 phase and there is no error at 52C, the outdoor unit PCB (defective 52X01 circuit or 52X01 ) or indoor unit PCB (defective thermostat circuit) is defective. Repair NO (2) Defective outdoor unit PCB Replacement (Defective CT circuit) 5 [Discharge temperature error] Error display: Indoor unit Stays OFF Keeps flashing Red LED Green LED Is the discharge gas thermistror characteristics normal? YES Red LED Green LED Discharge gas temperature error? (At cooling/heating operation) Outdoor unit 5 time flash (1) Keeps flashing Check the unit side. • Insufficient refrigerant Charge the refrigerant (measure) • Is it the oveload operation? NO Discharge pipe thermistor replacement Is the unit normalized Error stop Operable NO Defective outdoor unit PCB Replacement (Defective discharge gas thermistor input circuit) 1078 90ºC 130ºC Discharge pipe temp. Check the unit side. • During cooling: Is FM0 operating? • During heating: Is FM1 operating? Are service valves (both liquid, gas) fully opened during both cooling and heating. • Is the installation space of indoor/ outdoor unit adequate? • Is there any short circuit air flow for indoor/outdoor units? FDC-HKXR 6 [Defective outdoor unit heat exchanger thermistor] Error display: Outdoor unit Indoor unit Red LED Stays OFF Green LED Keeps flashing Is the outdoor unit heat exchanger hermistor connector OK? YES Red LED Keeps flashing Green LED Keeps flashing Are the outdoor unit heat exchnger thermistor characteristics OK, is there any broken wire? NO YES NO Defective outdoor unit PCB → Replacement (Defective outdoor unit heat exchanger thermistor input circuit) Outdoor unit heat exchanger thermistor (ThO-R) Resistance temperature characteristics Defective outdoor unit heat exchanger thermistor → Replacement 15 Resistance (kΩ) Repair 10 5k Ω at 25°C 5 0 10 20 30 40 50 Temperature (°C) [Defective outdoor temperature thermistor] Error display: Outdoor unit Red LED Stays OFF Green LED Keeps flashing Is the outdoor air temperature thermistor connector connection OK? NO Repair YES Red LED Keeps flashing Green LED Keeps flashing Is the outdoor temperature thermistor characteristics OK, is there no broken wire? YES Defective outdoor unit PCB → Replacement (Defective outdoor temperature thermistor input cicuit) NO Defective outdoor temperature thermistor → Replacement 400 Temperature-resistance characteristics of outdoor temperature thermistor (ThO-A) 300 200 40 30 T < 0°C 20 T > 0°C 100 0 -50 10 0 50 Temperature [T] (°C) Thermistor resistance (kΩ) [T > 0°C] Indoor unit Thermistor resistance (kΩ) [T < 0°C] 7 0 1079 FDC-HKXR [Defective discharge gas thermistor] Error display: Outdoor unit Red LED Stays OFF Green LED Keeps flashing Is the discharge gas thermistor connector connection OK? Red LED Keeps flashing Green LED Keeps flashing Are thr discharge gas thermistor characteristics OK, is there no broken wire? YES NO NO Defective discharge gas thermistor → Replacement Repair 9 T< = 80°C 5 50 0 0 Stays OFF Keeps flashing Red LED Green LED 20 50 80 100 120 Temperature [T] (°C) 3 time flash Keeps flashing At 63H1 operation Did 63H1, operate? NO Defective outdoor unit PCB → Replacement (Defective 63H1, input circuit) YES 1. During cooling • Is the outdoor unit fan motor operating? • Is there no short circuit air circulation for the outdoor unit? • Is there sufficient space for air inlet & outlet? 2. During heating • Is the gas side service valve fully opened? • Is the indoor unit heat exchanger thermistor detached from the detector case? • Is the filter clogged? • Is the outdoor unit fan controlled by due to defective 63H2? 3. During colling / heating • Is the refrigerant charge excessive? Note (1) When the wire of 63H1 is broken from the moment of power on, the error E 40 is displayed 40 minutes later. If the operation is started in this period of time, the operation changes to the thermostat OFF state during cooing, and cool wind blow stops during heating operation. 1080 10 T> = 80°C Outdoor unit Indoor unit Green LED 100 Temperature-resistance characteristics of discharge gas thermistor(ThO-D) [63H, motion] Error display: Red LED Defective outdoor unit PCB → Replacement (Defective discharge gas thermistor input circuit) YES 0 Thremistor resistance (kΩ) [T > = 80°C] Indoor unit Thremistor resistance (kΩ) [T < = 80°C] 8 FDC-HKXR 10 [Power transistor overheating] Error display: Outdoor unit Indoor unit Red LED Stays OFF Green LED Red LED Keeps flashing Does the FMO rotate? YES Power transistor overheating(1) 4 time flash Green LED Keeps flashing Is the outdoor unit installation space proper? YES NO Does the IM (Inverter cooling fan) rotate? YES NO YES Defective inverter (Refer to 1090 page) NO Repair Note (1) The LD2 on the inverter control PCB lights for 3 minutes. Fin thermostat set value: 90°C open/83°C close 11 [Current cut] Error display: Outdoor unit Indoor unit Red LED Green LED Stays OFF Keeps flashing Red LED Green LED 1 time flash Keeps flashing Remarks: When current-cut occurs immediately after a start (the Hz value does not increase), check the LD3 on the inverter PCB if an error code is not indicated on the remote controller and the compressor does not operate. When this LD3 is ON, see the next page. Is the current (U,V,W) of the compressor at the normal level? YES NO • Is the power supply voltage correct (not too hight)? • Are the power supply wires oppropriate(not too thin)? • Is not it operated under overload • Isn't the compressor locked? • Is the insulation or winding resistance of the compressor motor proper? • Is the electronic expansion valve closed? • Is the installation space of indoor/outdoor unit adequate? • Is there any short circuit on the indoor/outdoor unit • During cooling: Is FMO operating? • At heating: • Is FM1 operating? • Is the service valve (gas side) opened fully? • Is the filter clogged? YES Power supply reset NO Defective inverter (Refer to 1090 page) YES Unit is normal (Malfunction by accidental noise) Notes (1) The LD3 lights for 3 minutes. (2) For details of the check procedure, see the next page. 1081 FDC-HKXR Current cut is indicated and the compressor cannot operate Is the insullaiton resistance of the compressor(1) proper? Disconnect the compressor wiring NO Defective compressor YES The compressor can operate Is the current cut function activated? Notes (1) When a short-circuit or ground-fault occurs in the compressor motor, the current cut function is also activated. Notes (1) If the insulation resistance is 10MΩ or more, it is normal. Notes (1) The insulation resistance may considerably drop depending on the refrigerant volume in the compressor, but this is not faulty. (2) 1-2 seconds after a start: FDCP2001 type: Approx. 32 A FDCP2501 type: Approx. 37 A YES Defective inverter (Refer to 1090 page) NO Is the output voltage of the inverter normal? NO Defective inverter (Refer to 1090 page) YES When the compressor wiring is performed, the unit can operate. Isn't the stating current(2) excessive? YES Defective compressor NO Defective inverter Inverter output voltage Frequency Unit: V (AC) 35 Hz 40 Hz 65 Hz 75 Hz 80 Hz 95 Hz Model All models (outdoor unit) 1082 95 ~ 98 104 ~ 107 167 ~ 173 180 ~ 190 195 ~ 197 198 ~ 203 FDC-HKXR 12 [Excessive number of indoor units connected] Error display: Outdoor unit Indoor unit Red LED Stays OFF Green LED Red LED Keeps flashing 7 time flash Green LED Keeps flashing (1) Doesn't the number of indoor unit connected exceed the specified value? YES Repair Notes (1) The maximum number of connectable unit of each model is as follows: 9. (2) Outdoor No. setting check for indoor units (to see if outdoor No. is of other system) (3) In case of auto addressing erase the addresses stored in memory and perform re-setting. NO Power supply reset Is it normalized YES Defective indoor outdoor unit PCB → Replacement NO Unit is normal (malfunction by accidental noise) 13 [Transmission error between inverter and Outdoor unit PCB] Error display: Check that the 52C is ON. With the 52C ON, power is supplied to the inverter PCB. Outdoor unit Indoor unit Red LED Green LED Stays OFF Keeps flashing Red LED 9 time flash Green LED Keeps flashing Does the LD1 (Green) on the inverter PCB flash? NO NO • Defective inverter PCB • Defective outdoor unit PCB The inverter PCB cannot receive signals YES Does the LD4 (red) on the inverter PCB light? (2) Is the power supply line normal? YES Defective inverter PCB NO Repair NO • Defective inverter PCB • Defective outdoor unit PCB • Broken Cnl in No.5 (See next page) - The outdoor unit PCB cannot receive signals. - The inverter PCB cannot send signals. - The watch dog signal cannot be taken. Notes (1) Make a check referring to Troubleshooting for Inverter (page 1090). (2) When receiving fails, the LD4 comes on at once. If the outdoor unit cannot receive signals for 10 seconds, the 52C is turned OFF. Accordingly, the ON state can be checked only in this period of 10 seconds. 1083 FDC-HKXR • When communication is checked by the connector CnI, each value will be as follows. Contents of communication Connector CnI 14 1 Common 2 12V power supply 3 Transmission from outdoor unit 4 Reception from outdoor unit 5 Watch dog (communication from inverter PCB to outdoor unit PCB) 6 Inverter overheat 7 Current cut 12V Green LED Swings at 4.5~5V Outdoor unit Stays OFF Red LED Keeps flashing Are automatic address and manual address coexstent on the same network Green LED YES Stays OFF Keeps flashing Repair to manual address NO Defective outdoor unit PCB → Replacement (d) How to advance checks for each faulty symptom (i) Inspection method when there is no error display 1) Four way valve does not switch during heating operation Power supply detected between outdoor unit terminal 5 ~PCB faston terminal 6 (black)? NO Defective outdoor unit PCB → Replacement 1084 YES Swings at 2~4V 5V: normal 0V: abnormal Indoor unit Red LED Swings at 11~11.5V [Automatic address setting and manual address setting coexstents in the same network] Error display: V(analog tester) 0V Defective 20 S → Replacement FDC-HKXR 2) Louver motor does not operate Inspect at the indoor unit side. Does the louver operate at power on? Operate more than 1 min. later NO Is LM wire bloken? YES NO Is LM locked? Defective indoor unit PCB YES YES Replace LM Repair the wire Is the louver YES operated with the remote controller NO Normal NO Note (1) LM:Louver motor LS:Limit switch It is normal if it stops with 2 pushes on LS Turn off and back on again the power and check the motion of LS Does the louver link push the LS till a click sound is heard? NO Adjust LS lever and check again YES Defective LS → Replacement Defective indoor unit PCB →Replacemet 3) When the indoor unit blower does not operate Inspect at the indoor unit side. All of cooling, blower heating,thermaldry do not operate When some modes only operate. NO Defective indoor unit PCB → Replacement YES Check with the Hi, Me, Lo of blower mode. Check FMI Is Voltage detected between CNF terminals? NO Defective indoor unit PCB → Replacement YES Defective FMI, capacitor (CF I) → Replacement 1085 FDC-HKXR 4) Heating operation does not start NO Is heat outputted? Defective indoor unit PCB → Replace. YES (1) Are solenoid valve control relays OK? NO Defective relay → Replace. YES Is AC 200V applied at shunt controller connector CnB? YES Defective SVH (high pressure gas side solenoid valve) → Replace. 1086 NO Defective relay (XH) → Replace. Note (1) This is applicable only when a concentrated shunt controller is used. FDC-HKXR (3) When the remote controller indication is nomal but the compressor cannot operate: (No check indication) • Give instructions so that the requested best frequency may be output, irrespective of the thermostat condition, from outdoor to indoor. A ccordingly, if the indoor/outdoor transmission is faulty, the compressor cannot operate. • When the SW3-4 is turned on, error indication is not provided if the indoor unit is not connected. At remote controller operation, check if E3 (no mate) or E5 (transmission error) is indicated. Turn on the SW3-4 on the outdoor unit PCB (See page 1075) NO Do voltage appear at the 52C coil? Is the 52C turned ON? YES YES Defective 52C → Replacement NO Defective outdoor PCB Can the compressor operate? YES Continued from the next page • Is the indoor unit suction thermistor nomal? • Doesn't the thermistor stop? NO Does the LD1 (green) on the inverter PCB blink? NO Defective inverter PCB (See page 1091) YES Turn off the SW3-4 on the outdoor unit PCB Strap the connector Cn15 on the inverter PCB(1) Full load to command an unconditonal 35Hz operation from the inverter PCB Turn on the 52C forcedly (Manual operation) Can the compressor operate YES Defective outdoor unit control PCB NO Does a voltage appear at U.V and W of the compressor? NO Defective inverter PCB (See page 1091) YES Defective compressor Notes (1) The expansion valve of the indoor unit may be closed or the indoor unit fan may stop. After the compressor is operated, stop it at once. Otherwise, this will cause a failure to the compressor. (2) The next page shows a checking procedure using only the outside unit. 1087 FDC-HKXR (4) Proceduer for checking the outdoor unit irrespective of indoor/outdoor transmission Turn off the outdoor unit power supply (Or pull out the connector CnA2 on the outdoor unit PCB) Set 45 in outdoor unit No. Turn ON the outdoor unit PCB(SW3-7) Turn ON the outdoor unit power supply Open the 63H1 Is the 52C turnd ON? (When connecting the CnA2 on the outdoor unit PCB) (Pull out Faston No.17 on the PCB) NO Does a voltage Appear at the 52C coil. YES Defective 52C NO YES Defective outdoor unit PCB YES Can the compressor operate at 35Hz? Defective outdoor unit PCB or indoor unit PCB NO Turn OFF the outdoor unit power supply Return outdoor unit NO. to the installation state. 1 (Continued to the previous page) Note (1) When using this procedure, the indoor unit enters a transmission error state. In the indoor unit the expansion valve may be closed or the fan may stop. Note( 1) After the compressor is operated, stop it at once. Note (1) Otherwise, it will cause a failure to the compressor. 1088 FDC-HKXR (5) Procedure for checking the inverter (No output is provided at the compressor (U,V and W).) NO Is the 52C ON? Check the control PCB on the outdoor unit side NO Power line failure NO Does the LD1 (green) on the inverter PCB flash? Does DC280V appear at the connector Cn2 on the inverter PCB NO (3) The remote controller error code E45 is indicated (See page 1083) YES YES Turn OFF the power supply and pull out the connectors Cn13 and 14 Defective inverter PCB Turn ON the power supply Does DC1.5~1.6V appear at the connectors CN13 an 14 on the inverter PCB? (1) YES NO Defective inverter PCB (2) Defective power transistor Notes (1) Cn13 and Cn14 check points Tester bar + Cn13-7 Cn13-6 Cn13-11 Cn13-10 Cn13-15 Cn13-14 Cn14-1 Cn14-4 Cn14-2 Cn14-5 Cn14-3 Cn14-6 Voltage 1.5~ 1.6V (2) Check the wirng between the power transistor module and inverter PCB. If it is normal, judge that the power transistor module is fauly. (3) The 52C turns on, then turn off in 10 seconds. This is repeated 3 times and E45 is indicated. (iii) Cooling(heating) effectiveness is low. (Check the refrigerant volume and refrigerating cycle in addition to the following items.) 1) For low cooling effectiveness a) Check if the protective function operates with the result that the operating frequency of the compressor goes below the specified frequency value. Note (1) When the current safe control and discharge temperature control are activated, the frequency is lowered. b) Check if the operation of the indoor unit expansion valve is normal or there is no clogging. c) Check if the anti-frost function operates. Procedure for Checking Indoor unit Electronic Expansion Valve Operation Check the indoor unit controller to expansion valve output according to the following procedure. Measure the voltage value appearing at the pin on the control side of the expansion valve (SM) connector CnA (white, 6P (5-conductor), and also the duration of voltage application. Orange~Gray, Yellow~Gray Approx DC5V(2) for 15 seconds(1) when the power supply is turned on. Red ~Gray, Black ~Gray Notes (1) After the power supply is turned on, the voltage is about 5 V for 8 seconds, decreases momentarily, and then is kept at about 5 V for about 7 seconds. (2) When a measurement is made with a digital multitester, voltages of 6-3 V are output in sequence. } When the above duration and voltage value can be verified, the indoor unit controller is normal. If the expansion valve does not operate (no operating sound is produced) though a voltage is provided, the expansion valve is faulty. By changing the setting of the thermostat, the expansion valve is operated in about 20 seconds. Like the above, a DC voltage of about 5 V can be checked at the connector CnA. 2) Low heating effectiveness. a) Check if the operating frequency of the compressor is lowered below the specified frequecny because the protective function is activated. Note (1) When high pressure control [63H2 ON: 2.26 open/2.84 closeMPa (23 open/29 close kgf/cm2)], current safe control and discherge temperature control is exerted, the frequecny is lowered. b) Check if the operation of the outdoor unit expansion valve is normal, or if any clogging occurs. 1089 FDC-HKXR ◆ Troubleshooting on the inverter side (1) Troubleshooting procedure (For the details of 1 to 7, refer to Outfoor Unit Check Pointd on the next page.) NO Check the outdoor unit control PCB. NO Is DC280V is YES provided at the Cn2 on the inverter PCB? Is 52C turned ON? Does the LD1 (green) on the inverterYES PCB flashing YES Defective inverter PCB → Replacement. NO 1 Defective inverter PCB → Replacement NO Is DC280V provided between + and - of the capacitor? Is an outdoor provided at the Cn13 YES and 14 on the inverter PCB? YES 2 Defective power transistor module → Replacement NO Is AC200V provided at U, V and YES W on the power transistor module? Check the wire between the capacitor and Cn2 and check the connector. NO 3 Is the capacitor normal? YES Check the compressor. YES NO Defective capacitor → Replacement. YES 4 Is there continuity in the reactor? NO Defective reactor → Replacement. NO Defective resistance R1 → Replacement. NO Defective 73X → Replacement. YES 5 Is the resistance value of the resistance R1 is proper? YES Is the 73X good? (FDCP2501 type only) YES 6 Is the diode module good? NO Defective diode module → Replacement. YES 7 Is there continuity in the noise filter? YES Check the 52C. 1090 NO Defective noise filter → Replacement. N L3 L2 L1 TB Green Control board Normality LED2 check: If this LED flashing, the operation of the microcomputer is normal. Red LED1 LED2 * CNA2 CNA1 52C 1 2 3 4 5 6 7 Noise filter When the tester bars are reversed, the resistance value is about 10 ~ 20 Ω 8 ~ ~ ~ Cn1 Inverter overheating Current cut 6 7 4 5 Reception from outdoor unit 3 Watch dog (communication from the inverter circuit board to the outdoor unit PCB) 12 V power supply Transmission from outdoor unit 2 Common Contents of communication 1 Connector 5V: normal, 0V: abnormal 5V: normal, 0V: abnormal Swings between 2V and 4V. Swings between 4.5V and 5V. Swings between 11V and 11.5V. 12V 0V V (analog tester) 6.8 Ω Tester bar (black) Green Red Red Red LD1 LD2 LD3 LD4 Cn5 it is normal. LD2: Power transistor overheating LD3: Current cut LD4: Serial transmission error On the above occasion, these LDs light up. Frequency 95~98 35Hz 104~107 40Hz + Cn13 Resistance module Cn8 Cn10 Cn12 Cn7 Cn9 Cn11 23F Cn3 * 1 2 3 6 7 10 11 14 15 167~173 65Hz 1 Cn14- 6 Cn14- 5 Cn14- 3 Cn14- 2 Cn13-15 DC 1.5 ~ 1.6V Cn14- 1 Cn14- 4 Cn13-14 Cn13- 7 Cn13-11 Cn13- 6 Voltage Cn13-10 (-) (+) Tester bars Inverter PCB output check: Disconnect the connector and measure the signal output to the power transistor module. Cn14 W V U 180~190 75Hz 1 2 3 4 5 6 9 12 14 Power transistor module Check the appearance for crack or damage. FDC 2001, 2501 type Modells 195~197 80Hz CM 198~203 95Hz Power transistor output check: Disconnect the Faston terminal of the compressor and measure the output voltage. (The output 2001 is for the case whese the inverter is not loaded.) Unit: V (AC) 2 Inverter circuit board Cn2 1 2 3 4 check: * LD1 When this LED flashing every 0.5 second, 1 2 3 4 5 6 7 + 3 Tester bar (red) Mark Check the appeaeance for damage and blister and check the charging characteristic with a tester. (The indicator swings and returns slowly. After changing the polarity, perform the same operation. If the indicator returns, this is regarded as normal.) Capacitor check: 4 CT DC280V Reactor continuity check: After disconnecting the connector and make a continuity check. At that time, there should be continuity. + FDCP2001, 2501 Resistor R1 inspection R1 5 When a check is made at the connector Cn1, the values become usually as shown in the following table. Transformer Transformer check: Disconnect the connector CNA1. There should be continuity on the primary side. Tr Power check: Measure the power at the L1, L2, L3 and N on the terminal block TB. Fuse check: There should be continuity. * 7 When the result is OK Cn1 Noise filter check: There should be continuity. Tester bar + ~ + ~ Cn1 Outdoor Unit Check Points Check the part marked * while the power supply is turned ON. Make checks after the power supply is turned OFF, or after removing each part. 6 Power cable check: To see if there is continuity and connections are correct. Diode module check FDC-HKXR 1091 FDC-HKXR MEMO 1092 19.2.1 Specifications (1) Indoor unit FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTWJ28HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 90HKXE2B 112HKXE2B 140HKXE2B FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDRJ22HKXE2 28HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDUMJ36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDEJ36HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 112HKXE2B 140HKXE2B FDKJ22HKXE2 28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 (2) Outdoor unit Refrigerant R22 use models FDCJ140HKXE2B 224HKXE2B 280HKXE2B Alternative refrigerant R407C use models FDCP140HKXE2B 224HKXE2B 280HKXE2B 19.2.3 Exterior dimensions (1) Indoor unit FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTWJ28HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 90HKXE2B 112HKXE2B 140HKXE2B FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDRJ22HKXE2 (Silent Panel) (Canvas Panel) FDUMJ36HKXE2 28HKXE2 (Silent Panel) (Canvas Panel) 45HKXE2 45HKXE2 (Silent Panel) (Canvas Panel) 56HKXE2 56HKXE2 (Silent Panel) (Canvas Panel) 71HKXE2 71HKXE2 (Silent Panel) (Canvas Panel) 90HKXE2 90HKXE2 (Silent Panel) (Canvas Panel) 112HKXE2 112HKXE2 (Silent Panel) (Canvas Panel) 140HKXE2 140HKXE2 (Silent Panel) (Canvas Panel) FDEJ36HKXE2B FDKJ22HKXE2 45HKXE2B 28HKXE2 56HKXE2B 36HKXE2 71HKXE2B 45HKXE2 112HKXE2B 56HKXE2 140HKXE2B 71HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 (2)Remote controller (optional parts) (3) Outdoor unit Refrigerant R22 use models FDCJ140HKXE2B 224HKXE2B 280HKXE2B Alternative refrigerant R407C use models FDCP140HKXE2B 224HKXE2B 280HKXE2B 19.2.6 Selection chart (1) Correct the cooling and heating capacity in accordance with the conditions as follows. (2) Correction Correction of of outdoor outdoor unit unit capacity capacity according according to to capacity capacity of indoor unit to be operated simultaneously FDCJ/FDCP140HKXE2B 224HKXE2B 280HKXE2B (3)Sensible heat capacity FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDUMJ36HKXE2 FDEJ36HKXE2B 45HKXE2 45HKXE2B 56HKXE2 56HKXE2B 71HKXE2 71HKXE2B 90HKXE2 112HKXE2B 112HKXE2 140HKXE2B 140HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 FDRJ22HKXE2 28HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDKJ22HKXE2 28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 19.3.1 Electrical wiring (1) Indoor unit (a) Ceiling recessed type(FDT) Modles All models (b) 2-Way outlet ceiling recessed type(FDTW) Models All models (c) 1-Way outlet ceiling recessed type(FDTS) Models All models (d) Cassetteria type(FDR) Models All models (e) Satellite ducted type(FDUM) Models All models (f) Ceiling suspension type(FDE) Models All models (g) Wall mounted type(FDK) Models All models (h) Floor standing exposed type(FDFL) Modles All models (i) Floor standing hidden type(FDFU) Modles All models (2) Outdoor unit Refrigerant R22 use models FDCJ140HKXE2B 224HKXE2B 280HKXE2B Alternative refrigerant R407C use models FDCP140HKXE2B 224HKXE2B 280HKXE2B 19.5 APPLICATION DATA SAFETY PRECAUTIONS 19.5.1 Installation of indoor unit (1) Ceiling recessed type(FDT) (2) 2-Way outlet ceiling recessed type(FDTW) (3) 1-Way outlet ceiling recessed type(FDTS) (4) Cassetteria type(FDR) (5) Satellite ducted type(FDUM) (6) Ceiling suspension type(FDE) (7) Wall mounted type(FDK) (8) Floor standing exposed type(FDFL) (9) Floor standing hidden type(FDFU) 19.6 MAINTENANCE DATA (1)Before starting troubleshooting (P904 ~ P908) (2)Procedures of trouble diagnosis (P908 ~ P933) (3)Trouble diagnosis at the inverter side (P933 ~ P934) 20.2.1 Specifications (1) Indoor unit FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTWJ28HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 90HKXE2B 112HKXE2B 140HKXE2B FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDRJ22HKXE2 28HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDUMJ36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDEJ36HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 112HKXE2B 140HKXE2B FDKJ22HKXE2 28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 (2) Outdoor unit Alternative refrigerant R407C use models FDCP2001HKXRE2 2501HKXRE2 20.2.3 Exterior dimensions (1) Indoor unit FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTWJ28HKXE2B 45HKXE2B 56HKXE2B 71HKXE2B 90HKXE2B 112HKXE2B 140HKXE2B FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDRJ22HKXE2 (Silent Panel) (Canvas Panel) FDUMJ36HKXE2 28HKXE2 (Silent Panel) (Canvas Panel) 45HKXE2 45HKXE2 (Silent Panel) (Canvas Panel) 56HKXE2 56HKXE2 (Silent Panel) (Canvas Panel) 71HKXE2 71HKXE2 (Silent Panel) (Canvas Panel) 90HKXE2 90HKXE2 (Silent Panel) (Canvas Panel) 112HKXE2 112HKXE2 (Silent Panel) (Canvas Panel) 140HKXE2 140HKXE2 (Silent Panel) (Canvas Panel) FDEJ36HKXE2B FDKJ22HKXE2 45HKXE2B 28HKXE2 56HKXE2B 36HKXE2 71HKXE2B 45HKXE2 112HKXE2B 56HKXE2 140HKXE2B 71HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 (2)Remote controller (optional parts) (3) Individual flow divide controller (Optional Part) (4) Outdoor unit Alternative refrigerant R407C use models FDCP2001HKXRE2 2501HKXRE2 20.2.6 Selection chart (1) Correct the cooling and heating capacity in accordance with the conditions as follows. (2) Correction Correction of of outdoor outdoor unit unit capacity capacity according according to to capacity capacity of indoor unit to be operated simultaneously Alternative refrigerant R407C use models FDCP2001HKXRE2 2501HKXRE2 (3)Sensible heat capacity FDTJ28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDTSJ22HKXE2B 28HKXE2B 36HKXE2B 45HKXE2B 71HKXE2B FDUMJ36HKXE2 FDEJ36HKXE2B 45HKXE2 45HKXE2B 56HKXE2 56HKXE2B 71HKXE2 71HKXE2B 90HKXE2 112HKXE2B 112HKXE2 140HKXE2B 140HKXE2 FDFLJ28HKXE2 45HKXE2 71HKXE2 FDFUJ28HKXE2 45HKXE2 56HKXE2 71HKXE2 FDRJ22HKXE2 28HKXE2 45HKXE2 56HKXE2 71HKXE2 90HKXE2 112HKXE2 140HKXE2 FDKJ22HKXE2 28HKXE2 36HKXE2 45HKXE2 56HKXE2 71HKXE2 20.3.1 Electrical wiring (1) Indoor unit (a) Ceiling recessed type(FDT) Modles All models (b) 2-Way outlet ceiling recessed type(FDTW) Models All models (c) 1-Way outlet ceiling recessed type(FDTS) Models All models (d) Cassetteria type(FDR) Models All models (e) Satellite ducted type(FDUM) Models All models (f) Ceiling suspension type(FDE) Models All models (g) Wall mounted type(FDK) Models All models (h) Floor standing exposed type(FDFL) Modles All models (i) Floor standing hidden type(FDFU) Modles All models (2) Individual flow divide controller (3) Outdoor unit Alternative refrigerant R407C use models FDCP2001HKXRE2 2501HKXRE2 20.5 APPLICATION DATA SAFETY PRECAUTIONS 20.5.1 Installation of indoor unit (1) Ceiling recessed type(FDT) (2) 2-Way outlet ceiling recessed type(FDTW) (3) 1-Way outlet ceiling recessed type(FDTS) (4) Cassetteria type(FDR) (5) Satellite ducted type(FDUM) (6) Ceiling suspension type(FDE) (7) Wall mounted type(FDK) (8) Floor standing exposed type(FDFL) (9) Floor standing hidden type(FDFU) 20.6.1 Diagnosis of Microcomputer circuit (1) Confirmation of the error code on the remote controller (by pressing the inspection switch) and the inspection display and normal display lamps on PCBs of indoor/ outdoor units (P1068 ~ P1072) (2) Procedures of trouble diagnosis (P1072 ~ P1087) (3) When the remote controller indication is nomal but the compressor cannot operate:(No check indication) (P1087 ~ P1091)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project