Intel AXX Module, S5000, SR Series Server Boards Quick Start Guide
PDF
Dokument
Reklaam
Reklaam
= Main Power Cable, CPU A CAUTION: Note the location of the latch on each power cable connector and Make Server Board Power Connections Power Cable and Power Signal Cable Drive and align it with the matching tab on each server board socket. O Attach the main power © IMPORTANT NOTE: If you are using a non-Intel server chassis with an ATX power supply, see the documentation that came with your chassis for installation information. connector to the server P14 board. 4 O) Attach the CPU power mA connector as shown. @ Attach the aux. signal power connector. See the documentation Server Board chassis for drive installation. Main/CPU Power Connector Detail Second Serial Port Connection (optional) Attach serial connector to server board as shown. Serial Conn. Detail I/O Ports f ) Serial A y Server Board — — Note: For a non-Intel chassis, see your chassis documentation for serial connection requirements. Before installing your operating system, you must finish your chassis installation, | Network | Install Optical Hard Drive(s) that came with your server 9 43210 LE Connect Hard Drives/Optical Drive to Server Board Slimline Optical Drive Connector (Power + 1/0) Install 1/0 Expansion Module (optional) Remove Module Covers Prior to installing the 1/0 Expansion Module and/or the Intel9 RMM Module, you must remove the corresponding module cover(s). Install 1/0 Expansion Module (O) Install the three standoffs to the server board first. O Attach module to the server board connector and matching standoff holes. TN Install Intel” RMM Module O Squeeze the sides of each cover to disengage from the chassis back panel and remove. 1/0 Expansion Module (Dual Gigabit) 1/0 Expansion Module (External SAS) Snap --— (O) Install the three standoffs to the server board first. @ Attach module to the server board connector and matching standoff holes. Connect SATA Data Cables to server board here. © Begin cable connections at the SATA 0 location. SATA Data Cable Connector Attach Intrusion Switch Cable (optional) DS +" Intrusion Switch Connector Sw Note: This connection is not used in an Intel® Server Chassis. Рога non-Intel chassis, see your chassis documentation for intrusion switch requirements. NIC O Insert the standoff TH4 on the Intel9 Remote Management Module. The standoff installs on the bottom side of the Intel® Remote Management Module. © Attach the Intel® Remote Management Module to the server board connector and snap the standoff into : nap into the hole labeled Standoff * Install Intel” RMM Module Standoff Snaps into Server Board Hole || | the matching hole in the server board. Server Board I/O Ports Te | Le Install Intel® Remote Management Modules (optional) Inte? RMM Server Board — Connector Finishing Up Mouse o Software - Bios, Drivers, and Operating System Installation NIC2 ©, 10/100/ === A. Update the System Software: Г 1000 Mb 1. Boot from the Intel® Server Deployment Toolkit 2.0 CD. 2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware, and FRUSDRS. Note: Downloaded files on a USB Key may also be used. B. Configure your RAID Controller: Use the instructions provided with the RAID controller. make 1/0 connections | and plug in AC power. - 10/100/1000 Mb as NIC1 e board = y I с CAUTION: See your chassis documentation for AC power and — grounding requirements. IMPORTANT NOTE: You must download and install the latest Intel® RMM software for the Intel® RMM to work properly with your server hoard. <> Video systems, browse the CD folders to locate and install the driver files. USB 5-6 F. Install Intel SMaRT Tool (optional): C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel® Server Deployment Toolkit 2.0 CD. If using a Microsoft® Windows™ operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating E. Install Intel® Remote Management Software: Ifyou installed the Intel® Remote Management Module and the ASMI NIC, download and install the Intel® Remote Management Software from http://support.intel.com/support/motherboards/server/s500Opal. With the operating system running, insert the Intel® Server Deployment Toolkit 2.0 CD. The Express Installer will autorun. Click Intel® SMaRT Tool at the left side of the screen. Follow the on-screen instructions. For information about Intel® SMaRT Tool, see http://developer.intel.com/design/servers/smarttool/index.htm. System Fans 1-2 Server Board Note: These connections are not used in an Intel? Server Chassis. For a non-Intel chassis, see the "Making Connections ... Quick Reference" section below, and the documentation accompanying your chassis for specific chassis fan connection requirements. Front USB Connection (optional) USB Conn. Detail / mi Note: This connection is not used in an Intel® Server Chassis. For a non-Intel chassis, see your chassis documentation for front panel features and server board connection requirements. Main Power Ц See the documentation that came with your server chassis for add-in card installation. Install Add-in Cards Reference Accessories and Order Codes Slimline USB Floppy AXXUSBFLOPPY ATX 1/0 Shield and Gasket AALIO Dual Gig 1/0 Expansion Module | AXXGBIOMOD External 4 Port SAS AXXSASIOMOD ° Intel® Remote Management AXXRMM Module ° À complete list of accessories and spares can be found at: www.intel.com/go/serverbuilder e The Common Problems and Solutions For a list of hardware components that have been tested with this system, see: http://support.intel.com/support/motherboards/server/s5000pal/ The system does not boot or show video at power-on. This is typically the result of using an under-rated power supply. ... Quick Reference Required Connections for Selected Chassis B. +12V CPU Power Connector C. Main Power Connector D. Auxiliary Power Connector |. Bridge Board Connector SR1500 SR1550 SR2500 Check that +12V CPU power connector is plugged in. Without this cable the processor will not have any power. Beep code 4-3-2-1 in a system using a Dual-Core Intel® Xeon® Optional Connections for Selected Chassis SR1500 SR1550 SR2500 processor 5000 sequence (minimum of 2.67 GHz) means you have Ë ee OB = | wm unrecognized or bad memory. a F. Serial ATA Connector(s) N Remove and replace DIMMs one bank at a time to isolate which one G. Serial A Header N is causing problems. Remember, all DIMMs must be: Connections FBDIMM 533/667 MHz compliant 240-pin DIMMs The same speed. From the same manufacturer. Installed beginning with DIMM 1A. system sometimes works, but is exhibiting erratic behavior. These fan connectors are NOT USED in an Intel? Server Chassis. For a non-Intel server chassis, see the documentation that came with your chassis for fan connection requirements. Note: Not all optional connections are shown in this diagram. Refer to the Reference section of this Quick Start User's Guide, your Intel® Server Board S5000PAL Product Guide, and your server chassis documentation for additional connection information. Making Connections to the Server Board Serial A ZZ | | Control Panel USB Aux. Power Ss Su бои | | Ш Ш O 1] || | Й || LI || i Server Board Component Layout Main Power Conn. Intel® RMM NIC System Fan 3 ID LED Connector | | © Code LEDs || I/O Expansion - 7 , Modul | 5 i Serial + Connector D UA o © Intel® Local Control Æ © Panel Header 5 IPMB— > = Intrusion —jf, Intel? RMM 3 = =||S| 5) |) 5) 8) (5) | Recovery [E Connector = ||| ЕЕ RAID Key 5 = | LL SATA 5 SATA 4 SATA | (09900905 SATA 2 Bridge Board _ О — О — Connector , SATA 1 . . T J IDE Optical Drive | CPU? SATA 0 | O | т Socket Control Panel USB 0-1 Sys. Fan 1 Power | Sys. © © © © So sa tery Fan? [+ CPUFan2 CPU Fan 1 Signal | PU ОО Com. | © Power © CPU Voltage Regulator © ">
/
Laadi alla
Lihtsalt sõbralik meeldetuletus. Saate dokumenti vaadata otse siin. Kuid mis kõige tähtsam, meie AI on selle juba läbi lugenud. See suudab keerulisi asju lihtsate terminitega selgitada, teie küsimustele vastata mis tahes keeles ja aidata teil kiiresti navigeerida isegi kõige pikemates või keerulisemates dokumentides.
Reklaam