Datalogic PowerScan M8500 Readers bar code reader Quick Reference Guide
Below you will find brief information for bar code reader PowerScan M8500 Readers. This document provides instructions for using the PowerScan M8500 barcode reader, including setting up the device, connecting it to a base station, and configuring the settings. It also covers how to charge the battery and use the LED indicators and beeper.
Advertisement
Advertisement
PowerScan™ M8500 Readers
Industrial Handheld Area Imager Bar Code Reader with Datalogic’s STAR Cordless System™
Quick Reference Guide
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A and the E.U. All other brand and product names referred to herein may be trademarks of their respective owners.
PowerScan is a registered trademark of Datalogic Scanning, Inc. in many countries, including the U.S.A.
Patents
This product is covered by one or more of the following patents.
Design Pat. AU 310201; AU 310202; CN 693980; CN735959; HK 0602013.5M001; HK
0602013.5M002; JP 1305693; KR 30-0460940; US D570,843 S; USD588,596 S.
US Pat. 5,992,740; 6,305,606 B1; 6,517,003; 6,808,114 B1; 6,997,385 B2; 7,387,246 B2;
5,367,151; 5,449,893; 5,545,889; 6,098,877; 6,220,514 B1; 6,412,698 B2; 6,607,132 B1;
6,817,529 B2; 6,834,805 B2; 7,948,214 B2.
European Pat. 789,315 B1; 895,175 B1; 1,128,314 B1; 1,128,315 B1; 1,396,811 B1;
1,413,971 B1; 1,816,585 B1; 1,942,442 B1.
Additional Patents pending.
Table of Contents
PowerScan™ M8500 Family ............................................................ 1
Using the PowerScan™ PM8500 Family ............................................... 2
Good Read Spot ................................................................................... 3
PowerScan™ M8500 Configuration ....................................................... 7
PowerScan™ M8500/BC-80X0 Point-to-Point Setup............... 7
PowerScan™ M8500/BC-80X0 Stand Alone Setup................... 8
Using Multiple Readers with Same Cradle................................11
PowerScan™ M8500/STAR-MODEM™ Stand Alone Setup ..11
PowerScan™ M8500/STAR-SYSTEM™ Setup.............................12
Datalogic Scanning Limited Factory Warranty .......................22
FCC Compliance .................................................................................25
Radio Compliance..............................................................................25
IC (Industry Canada)..........................................................................25
WEEE Compliance..............................................................................30
NOTES
PowerScan™ M8500 Family
Description
The PowerScan™ M8500 series readers can be used with either a BC-80X0 cradle or Stargate™ radio base station to build a Cordless Reading System for the collection, decoding and transmission of bar coded data. The M8500 series can be used in the same environment where M8300 series readers are already installed.
This manual includes just the commands required for the startup of the scanner and setting of the interface. For complete configuration of the scanner, refer to the
PowerScan™ PM8500 Reference Manual or the Datalogic Aladdin configuration program, both downloadable from the website and available on the included CD
ROM.
The PowerScan™ PM8500 Hand-Held Reader packs a lot of performance into an attractive, rugged, hand-held device. It operates in commercial and industrial environments, as well as the front office .
Omni-
Directional
Operating
To read a symbol or capture an image, you simply aim the reader and pull the trigger. Since the PowerScan™ PM8500 is a powerful omni-directional reader, the orientation of the symbol is not important.
Decoding
Formatting and
Concatenating
Autoscanning
Flash Memory
USA Driver
License Parsing
Thanks to powerful algorithms, PowerScan™ PM8500 reliably decodes all major 1D (linear) bar codes, 2D stacked codes (such as
PDF417), 2D matrix symbols (such as DataMatrix), postal codes (such as POSTNET, PLANET). The data stream — acquired from decoding a symbol — is rapidly sent to the host. The reader is immediately available to read another symbol.
The string of a decoded code may be processed according to either a simple or advanced data formatting and be concatenated to other codes (up to 4 different codes).
An autoscan command causes the reader to scan continuously and to monitor the central zone of its reading area.
Flash technology allows you to upgrade the PowerScan™ PM8500 reader as new symbologies are supported or as improved decoding algorithms become available.
The reader can be set up to select and output a subset of data elements from USA Driver License PDF417 bar codes. This feature can be enabled using either Datalogic Aladdin™ or the bar codes in the USA Driver License Parsing Quick Reference Guide (QRG), available on the Datalogic website.
The Powerscan M8500 is compatible with BC80x0 v3.0.0.00 (available in the Aladdin Software on the CD included with this product) and later releases. If a previous firmware version is installed in your BC80x0, please upgrade to the latest version before installing the M8500.
Quick Reference Guide 1
Using the PowerScan™ PM8500 Family
Using the PowerScan™ PM8500 Family
The PowerScan™ PM8500 normally functions by capturing and decoding codes.
The PowerScan™ PM8500 reader uses an intelligent aiming system. By pulling the trigger, the aiming system indicates a field of view, which should be positioned over the code:
Aiming System
When you pull the trigger, a red beam illuminates the code. If the aiming system is centered and the entire symbology is within the aiming system, you will get a good read. The field of view changes size as you move the reader closer or farther away from the code.
Relative Size and Location of Aiming System Pattern
Linear bar code 2D Matrix symbol
Successful reading is signaled by an audible tone plus a good-read green LED.
The PowerScan™ PM8500 handheld reader aiming system is designed for general reading and decoding of 1D and 2D symbols. Some variation in reading distance will occur due to narrow bar width and other factors.
If reading codes positioned on reflective surfaces, it may be necessary to tilt the reader with respect to the bar code and/or set the Camera Control parameters. For configuring the Camera Control parameters refer to the
PowerScan™ PM8500 Product Reference Guide (PRG) available on the website and the CD.
2 PowerScan™ M8500
Indicators
Indicators
LED Indicators
The PowerScan™ PM8500 family uses green LED indicators to signal the following reader functions:
Power ON
STATUS
Normal Function
BEHAVIOR
At power-on, the LEDs blink briefly, then light up for 2 seconds to signal the power supply is present.
The LED lights up after a good decoding and will switch off only at the next trigger press.
Beeper
The PowerScan™ PM8500 basic software provides beeper signals for good/wrong reading and for indicating errors. Its tone, volume and duration can be directly configured by using the codes given in the PowerScan™ PM8500 Product Reference Guide (PRG) available on the website.
The application program can also manage the beeper (User Defined Beeper) when the reader is controlled by a Host PC. It is possible to activate the beeper by sending a command from the Host to the reader via the current communication interface.
Good Read Spot
A green good read spot will be projected in the field of view when the reading is successful.
Quick Reference Guide 3
4
Charging the Batteries
Charging the Batteries
Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries.
Place the PowerScan™ M8500 into the BC-80X0 cradle or the C-8000 battery charger. The "Reader" LED on the cradle/battery charger turns red.
The battery is completely charged when the "Reader" LED on the cradle/battery charger turns green.
To change the battery, push the Release Button as indicated by Arrow 1 and extract the battery pack from the reader handle. Then, insert the new battery pack into the reader handle until a ‘click’ is heard and the Release Button moves back to its neutral position.
1
2
PowerScan™ M8500
Charging the Batteries
WARNING
Do not discharge the battery using any device except for the scanner.
When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury.
Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions. Be sure to follow the safety warnings listed below:
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire).
• Do not carry or store the battery pack together with metal objects.
• Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow the battery to get wet.
• Do not apply voltages to the battery pack contacts.
In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
CAUTION
Always charge the battery at 32° – 104°F (0° - 40°C) temperature range.
Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty.
Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other high temperature locations.
Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure containers or on induction cookware.
Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the batteries should be expected to take 500 full discharge/charge cycles before needing replacement. This number is higher if partial discharging / recharging is adhered to rather than full / deep discharging,
The typical manufacturer advertised useful life of LI batteries is one to three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced. For most applications, batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns.
Quick Reference Guide 5
Setup
Collect and recycle waste batteries separately from the device in compliance with European Directive
2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about the environment.
Setup
PowerScan™ M8500/BC-80X0 Point-to Point Configuration
1.
Connect a BC-80X0 cradle to the Host. For installation and connection information see the BC-80X0 Quick Reference Manual.
2.
Charge the PowerScan™ M8500 battery using an BC-80X0 or the
C-8000 charger as described in this Quick Reference manual. A full charge takes 4 hours if using an external power supply; while it takes up to 10 hours if supplying power through the USB port.
3.
Configure the reader as described in this Quick Reference -
PowerScan™ M8500/BC-80X0 Point-to-Point Setup.
4.
Configure the BC-80X0 cradle. See BC-80X0 Configuration in the BC-
80X0 Quick Reference.
or
PowerScan™ M8500/BC-80X0 Stand Alone Configuration
1.
Connect an BC-80X0 cradle to the Host. For installation and connection information see the BC-80X0 Quick Reference Manual.
2.
Charge the PowerScan™ M8500 battery using an BC-80X0 or the
C-8000 charger as described in this Quick Reference manual. A full charge takes 4 hours if using an external power supply; while it takes up to 10 hours if supplying power through the USB port.
3.
Configure the reader as described in this Quick Reference -
PowerScan™ M8500/BC-80X0 Stand Alone Setup.
4.
Configure the BC-80X0 cradle. See BC-80X0 Configuration in the
BC-80X0 Quick Reference.
or
PowerScan™ M8500/STAR-System™ Configuration
1.
Charge the PowerScan™ M8500 battery using an BC-8000 or the
C-8000 charger as described in this Quick Reference manual. A full charge takes 4 hours if using an external power supply; while it takes up to 10 hours if supplying power through the USB port.
2.
Configure the reader as described in this Quick Reference -
PowerScan™ M8500/STAR-System™ Setup.
6 PowerScan™ M8500
PowerScan™ M8500 Configuration
PowerScan™ M8500 Configuration
PowerScan™ M8500/BC-80X0 Point-to-Point Setup
A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own BC-80X0 base station and where it is not necessary to set the Date and Time parameters.
A special pre-printed bind-address label provided in the BC-80X0 base station package can be used to bind the PowerScan™ M8500 reader to the base station with the address coded on the label. The address is also written numerically on the label to be easily recognized. Valid addresses are in the range from 0000 to 1999.
Make sure that all cradles used in the same area have different addresses.
To rapidly configure your point-to-point application:
1.
Apply the bind-address label onto the BC-80X0 base station as indicated in the BC-80X0 Quick Reference Manual.
2.
When the BC-80X0 cradle is connected and powered, read the Bind-
Address label to pair the PowerScan™ M8500 to the BC-80X0 cradle.
The green LED on the PowerScan™ M8500 will blink: the reader is ready to be positioned onto the cradle.
3.
Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan™ M8500, and the green LED on the reader will go off.
Green LED
If it ever becomes necessary to change the reader, just read the bind-address label applied to the cradle and position the new reader onto the cradle.
Do not use multiple readers with this configuration method.
4.
Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
END of procedure. YOUR READER IS NOW READY TO READ CODES.
Quick Reference Guide 7
PowerScan™ M8500 Configuration
PowerScan™ M8500/BC-80X0 Stand Alone Setup
When the BC-80X0 cradle is connected and powered, configure the PowerScan™
M8500 by reading the following codes in the given sequence and follow the instructions.
For the numeric code selection of steps 3, 4, and 5 use the table at the end of this Quick Reference
1.
Restore PowerScan™ M8500 Default
2.
Enter Configuration
8
3.
4.
Set Date
+ six digits for Day, Month and Year (DDMMYY).
Set Time
PowerScan™ M8500
5.
PowerScan™ M8500 Configuration
+ four digits for Hours and Minutes (HHMM).
Set Radio Address
6.
+ four digits for the PowerScan™ M8500 Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
Exit and Save Configuration
7.
Read the Bind code to pair the PowerScan™ M8500 to the BC-80X0 cradle.
The reader is dedicated to the cradle. Any previously bound reader will be excluded.
To connect several readers to the same cradle see the following section "Using
Multiple Readers with Same Cradle".
Bind
8.
The green LED on the PowerScan™ M8500 will blink: the reader is ready to be positioned onto the cradle.
Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan™ M8500, and the green LED on the reader will go off.
Quick Reference Guide 9
PowerScan™ M8500 Configuration
Green LED
9.
Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
END of procedure. YOUR READER IS NOW READY TO READ CODES.
10 PowerScan™ M8500
PowerScan™ M8500 Configuration
Using Multiple Readers with Same Cradle
If you want to use several readers associated with the same cradle, you must first
Bind the cradle with one of the readers (see previously described configuration procedure).
Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join.
7.
Join
The green LED on the PowerScan™ M8500 will blink: the reader is ready to be positioned onto the cradle. Complete step 8.
END of procedure.
All readers associated with the same cradle must have different addresses.
CAUTION
PowerScan™ M8500/STAR-MODEM™ Stand Alone Setup
To configure a PowerScan™ M8500 reader to communicate with STAR-
Modem™ in Stand Alone Mode, follow the "PowerScan™ M8500/BC-80X0
Stand Alone Setup" procedure substituting steps 5 and 6 with those below:
6.
STAR-Modem™ Address
7.
Read the code above and the four-digit address of the STAR-Modem™.
Exit and Save Configuration
END of procedure. YOUR READER IS NOW READY TO READ CODES.
Quick Reference Guide 11
PowerScan™ M8500 Configuration
PowerScan™ M8500/STAR-SYSTEM™ Setup
The following procedure allows configuring a PowerScan™ M8500 reader to communicate with various STAR-System™ devices such as Stargate™ RF base stations:
1.
Restore PowerScan™ M8500 Default
2.
Enter Configuration
3.
Set Date
4.
12
+ six digits for Day, Month and Year (DDMMYY).
Set Time
+ four digits for Hours and Minutes (HHMM).
PowerScan™ M8500
5.
PowerScan™ M8500 Configuration
Set the connection according to the length of the codes to be read:
Code Length
240 Characters
Code Length
240 Characters
(not for systems with BC-80X0 as Master)
6.
Set Radio Address
7.
+
four digits from the Numeric Table for the PowerScan™ M8500 Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
Set First STAR-System™ Address
+
four digits from the Numeric Table in the range 0000 to 1999
Quick Reference Guide 13
PowerScan™ M8500 Configuration
8.
Set Last STAR-System™ Address
9.
+
four digits from the Numeric Table in the range 0000 to 1999
Whenever the system is composed of a single base station, the first and last base station addresses (steps 7 and 8) must have the same value.
Exit and Save Configuration
END of procedure. YOUR READER IS NOW READY TO READ CODES.
14 PowerScan™ M8500
Default Configuration
Default Configuration
DATA FORMAT – Symbology Dependent Parameters symbology specific format = select all, no headers, no terminators, symbology character substitution disabled, symbology character deletion disabled
DATA FORMAT – Concatenation
Concatenation disabled, 2 EAN/UPC codes concatenated, Set First Concatenated Code
Length 000 = any length, Set Second Concatenated Code Length 000 = any length, Set
Third Concatenated Code Length 000 = any length, Set Fourth Concatenated Code Length
000 = any length, Concatenation with Intercode Delay disabled, Concatenation Timeout 10 seconds, Concatenation Failure Transmission = Tx codes causing failure, Transmission after
Timeout = No code transmission, Concatenation Result Code ID = No code Identifier
ADVANCED FORMATTING PARAMETERS format disabled
CAMERA CONTROL exposure mode = automatic, based on entire image
CODE SELECTION issue identical codes = enable enabled codes
Standard Code 39: no check digit control, variable code length;
EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled
Code 128: variable code length
PDF417
Datamatrix: rectangular, normal and inverted, variable code length
QR disabled codes
Code 32, Interleaved 2/5, Codabar, Code 93, EAN 128, GS1 DataBar™, Micro PDF417, Postal
Codes, Maxicode, Composite Codes, Aztec, microQR, IMB.
READING PARAMETERS trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec, beeper tone = tone 1, beeper volume = high, beeper duration = 50 ms, user defined beeper = tone 1, user defined beeper volume = high, user defined beeper duration = 100 ms, code per scan = one code per scan, read per cycle = one read per cycle, scan timeout = 5 sec, central code transmission = disabled, order by code length = disabled, order by code symbology = disabled, autoscan mode = disabled, autoscan aiming system = enabled, autoscan hardware trigger = enabled, autoscan illumination system = disabled, stand autoscan mode
= normal, aiming system delay = disabled, good read spot = short, safety time = 500 ms
RADIO PARAMETERS radio protocol timeout = 2 seconds, power-off timeout = 4 hours, transmission mode = one-way, beeper control for radio response = normal, single store = disabled, batch mode = disabled, find me = enabled, radio RX timeout = disabled
Quick Reference Guide 15
Operating Test
Operating Test
EAN-13
1 234567 000992
Code 128 t e s t
QR
Code 39 (Standard)
1 7 1 6 2
PDF417
Data Matrix (Normal)
16 PowerScan™ M8500
Technical Features
Technical Features
PowerScan™ M8500 Family Common Features
Electrical Features
Battery Type
Time of recharge
2150 Li-Ion battery pack max. 4 hours with external power supply max. 10 hours with Host power
30,000 reads (typical) Operating autonomy
(continuous reading)
Display
(Only available with some models)
Indicators
LCD 4 lines x 16 chars
Programmable font and backlight
Radio Features
Radio Frequency
Bit rate
Range (in open air)
System Configuration
Max. number of devices per base station
Max. number of devices in the same reading area
Good Read LED green
Good Read Spot green
Beeper
European Models
433.92 MHz
USA Models
910 MHz
19200 baud exceed 50 m
36800 baud exceed 30 m
BC-80X0
STARGATE™
32
2000
Environmental Features
Operating Temperature
Storage Temperature
Humidity
Drop Resistance
IP Sealing
Mechanical Features
Weight (with batteries)
Dimensions
Material
Decoding Capability
1D
2D
Postal Codes
-10° to +50° C (+14° to +122° F)
-20° to +70° C (-4° to +158° F)
0 to 95% NC
2 m / 6.6 ft (over 50 drops to concrete)
IP65 (IP64 for models with display) about 360 g (12.70 oz)
212 x 109 x 71 mm (8.34 x 4.29 x 2.79 in)
Polycarbonate molded with rubber
Interleaved 2 of 5, Code 39, Code 32, Code 128, EAN 128,
Code93, UPC/EAN/JAN, Codabar, GS1 DataBar™
Aztec, PDF417, Micro PDF417, Macro PDF417, Maxicode,
DataMatrix (ECC200), QR, Composite Codes
PLANET, Japan Post, Australia Post, KIX Code, Royal Mail Code
(RM4SCC)
Quick Reference Guide 17
Technical Features
PowerScan™ M8500 Family Common Features (continued)
Optical Features
Sensor
Illuminator
Wavelength
LED Safety Class
Aiming System
Wavelength
Laser Safety Class
Ambient light
1280 x 1024 pixel element, 2D CMOS Array
LED array
In the range 630 ~ 670 nm
Class 1 to EN 60825-1
Visible Laser Diode
650 nm
Class 2 - EN 60825-1; Class II CDRH
0 - 100000 lux
18 PowerScan™ M8500
Technical Features
PowerScan™ M8500™
Optical Features
Focus distance
Field of view
Horizontal field of view at distance (d) in mm
Vertical field of view at distance
(d) in mm
Max Resolution Linear codes - mm
(mils)
0.10 (4)
Depth of field*
1D (linear):
Code39
X-dimension mm (mils)
0.13 (5)
140 mm
28°(H )x 23°(V)
0.52d + 15
0.42d + 12
PDF417 - mm
(mils)
0.10 (4)
EAN13
2D:
PDF417
QR
DataMatrix
0.5 (20)
0.33 (13)
X-dimension mm (mils)
0.13 (5)
0.25 (10)
0.19 (7.5)
0.25 (10)
0.19 (7.5)
0.25 (10)
Datamatrix – mm
(mils)
0.17 (6.6)
DOF cm (in)
7.5 to 15.5
(2.95 to 6.10)
5.5 to 36.5
(2.17 to 14.37)
5.0 to 27
(1.97 to 10.63)
DOF cm (in)
8.0 to 18.5
(3.15 to 7.28)
4.0 to 25.5
(1.57 to 10.04)
8.0 to 16.5
(3.15 to 6.5)
7.0 to 19.5
(2.76 to 7.68)
8.0 to 16.5
(3.15 to 6.5)
7.0 to 19.5
(2.76 to 7.68)
Skew
Pitch
Rotation
Print Contrast (Min.)
±40°
±35°
360°
15%
* Reading distances are measured from the nose of the reader.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes.
Quick Reference Guide 19
Technical Features
PowerScan™ M8500™ HD
Optical Features
Focus distance
Field of view
Horizontal field of view at distance (d) in mm
Vertical field of view at distance
(d) in mm
Max Resolution Linear codes - mm
(mils)
0.05 (2 mils)
Depth of field*
1D (linear):
Code39
EAN13
2D:
PDF417
X-dimension mm (mils)
0.08 (3)
0.13 (5)
0.51 (20)
0.33 (13)
X-dimension mm (mils)
0.08 (3)
65 mm
27° (H) x 22° (V)
0.50d + 13
0.40d + 10
PDF 417 – mm (mils)
0.08 (3 mils)
QR
DataMatrix
Skew
Pitch
Rotation
Print Contrast (Min.)
0.13 (5)
0.25 (10)
0.10 (4)
0.19 (7.5)
0.25 (10)
0.10 (4)
0.19 (7.5)
0.25 (10)
Datamatrix – mm (mils)
0.10 (4 mils)
±40°
±35°
360°
23%
DOF cm (in)
4.5 to 8.0 (1.77 to 3.15)
3.5 to 9.5 (1.38 to 3.74)
6.0 to 18.5 (2.36 to 7.28)
5.0 to 14 (1.97 to 5.51)
DOF cm (in)
5.0 to 8.5
(1.97 to 3.35)
4.5 to 9.5
(1.77 to 3.74)
3.0 to 13.0
(1.18 to 5.12)
5.5 to 7.5
(2.17 to 2.95)
5.0 to 8.0
(1.97 to 3.15)
4.5 to 9.5
(1.77 to 3.74)
5.5 to 7.5
(2.17 to 2.95)
5.0 to 8.0
(1.97 to 3.15)
4.5 to 9.5
(1.77 to 3.74)
Reading distances are measured from the nose of the reader.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes.
20 PowerScan™ M8500
Technical Features
PowerScan™ M8500™ WA
Optical Features
Focus distance
Field of view
Horizontal field of view at distance (d) in mm
Vertical field of view at distance
(d) in mm
Max Resolution Linear codes - mm
(mils)
0.13 (5 mils)
Depth of field*
1D (linear):
Code39
X-dimension mm (mils)
0.13 (5)
110 mm
57° x 46°
1.09d + 38
0.85d + 30
PDF 417 – mm
(mils)
0.13 (5 mils)
EAN 13
2D:
PDF417
QR
DataMatrix
0.51 (20)
0.33 (13)
X-dimension mm (mils)
0.13 (5)
0.25 (10)
0.19 (7.5)
0.25 (10)
0.19 (7.5)
0.25 (10)
Datamatrix – mm
(mils)
0.19 (7.5 mils)
DOF cm (in)
2.5 to 10.0
(0.98 to 3.94)
1.5 to 32
(0.59 to 12.60)
1.5 to 26.0
(0.59 to 10.24)
DOF cm (in)
3.0 to 10.5
(1.18 to 4.13)
1.5 to 21.5
(0.59 to 8.46)
5.5 to 8.5
(2.17 to 3.35)
3.0 to 12.5
(1.18 to 4.92)
5.5 to 8.5
(2.17 to 3.35)
3.0 to 12.5
(1.18 to 4.92)
Skew
Pitch
Rotation
Print Contrast (Min.)
±40°
±35°
360°
15%
Reading distances are measured from the nose of the reader.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes.
Quick Reference Guide 21
Services and Support
Services and Support
Datalogic provides several services as well as technical support through its website.
Log on to www.scanning.datalogic.com and click on the links indicated for further information including:
Products
Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including:
• Datalogic Aladdin™, a multi-platform utility program that allows device configuration using a PC. It provides RS-232 interface configuration as well as configuration bar code printing.
Service & Support
• Technical Support - Product documentation and programming guides and Technical Support Department in the world
• Service Programs - Warranty Extensions and Maintenance Agreements
• Repair Services - Flat Rate Repairs and Return Material Authorization
(RMA) Repairs.
• Downloads – Manuals & Documentation, Data Sheets, Product Catalogues, etc.
Contact Us
Information Request Form and Sales & Service Network
Warranty
Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years from the date of shipment, provided that the product is operated under normal and proper conditions.
Datalogic Scanning Limited Factory Warranty
Warranty Coverage
Datalogic Scanning (“Datalogic”) hardware products are warranted against defects in material and workmanship under normal and proper use. The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its normal operating condition. Repair or replacement of product during the warranty does not extend the original warranty term. Products are sold on the basis of specifications applicable at the time of manufacture and Datalogic has no obligation to modify or update products once sold.
22 PowerScan™ M8500
Warranty
If Datalogic determines that a product has defects in material or workmanship,
Datalogic shall, at its sole option repair or replace the product without additional charge for parts and labor, or credit or refund the defective products duly returned to Datalogic. To perform repairs, Datalogic may use new or reconditioned parts, components, subassemblies or products that have been tested as meeting applicable specifications for equivalent new material and products. Customer will allow
Datalogic to scrap all parts removed from the repaired product. The warranty period shall extend from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase (Warranty period).
Datalogic warrants repaired hardware devices against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period, whichever is longer. Datalogic does not guarantee, and it is not responsible for, the maintenance of, damage to, or loss of configurations, data, and applications on the repaired units and at its sole discretion can return the units in the “factory default” configuration or with any software or firmware update available at the time of the repair (other than the firmware or software installed during the manufacture of the product). Customer accepts responsibility to maintain a back up copy of its software and data.
Warranty Claims Process
In order to obtain service under the Factory Warranty, Customer must notify Datalogic of the claimed defect before the expiration of the applicable Warranty period and obtain from Datalogic a return authorization number (RMA) for return of the product to a designated Datalogic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace product without additional charge for parts and labor. Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center, with shipping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Datalogic service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
Failure to follow the applicable RMA policy, may result in a processing fee. Customer shall be responsible for return shipment expenses for products which Datalogic, at its sole discretion, determines are not defective or eligible for warranty repair.
Warranty Exclusions
The Datalogic Factory Warranty shall not apply to:
(i) any product which has been damaged, modified, altered, repaired or upgraded by other than Datalogic service personnel or its authorized representatives;
Quick Reference Guide 23
Warranty
(ii) any claimed defect, failure or damage which Datalogic determines was caused by faulty operations, improper use, abuse, misuse, wear and tear, negligence, improper storage or use of parts or accessories not approved or supplied by Datalogic;
(iii) any claimed defect or damage caused by the use of product with any other instrument, equipment or apparatus;
(iv) any claimed defect or damage caused by the failure to provide proper maintenance, including but not limited to cleaning the upper window in accordance with product manual;
(v) any defect or damage caused by natural or man-made disaster such as but not limited to fire, water damage, floods, other natural disasters, vandalism or abusive events that would cause internal and external component damage or destruction of the whole unit, consumable items;
(vi) any damage or malfunctioning caused by non-restoring action as for example firmware or software upgrades, software or hardware reconfigurations etc.;
(vii) the replacement of upper window/cartridge due to scratching, stains or other degradation and/or
(viii) any consumable or equivalent (e.g., cables, power supply, batteries, keypads, touch screen, triggers etc.).
No Assignment
Customer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee of product. No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic.
DATALOGIC'S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATUTORY
OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PAR-
TICULAR PURPOSE, OR NONINFRINGEMENT. DATALOGIC SHALL
NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUSTOMER
ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF
PRODUCTS UNDER THE ABOVE. THE REMEDY SET FORTH IN THIS
WARRANTY STATEMENT IS THE CUSTOMER’S SOLE AND EXCLU-
SIVE REMEDY FOR WARRANTY CLAIMS. UNDER NO CIRCUM-
STANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY
THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, CON-
SEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES
REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE
OF THE POSSIBILITY OF SUCH DAMAGES.
24 PowerScan™ M8500
Compliance
Risk of Loss
Customer shall bear risk of loss or damage for product in transit to Datalogic.
Datalogic shall assume risk of loss or damage for product in Datalogic’s possession.
In the absence of specific written instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
Compliance
This device must be opened by qualified personnel only.
The batteries must be removed before opening the device.
FCC Compliance
Modifications or changes to this equipment without the express written approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference which may cause undesired operation.
FCC ID U4F0015.
Radio Compliance
Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required.
Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm
for further information.
IC (Industry Canada)
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Aiming System Laser Beam Output Win dow
Laser warning and classification label
Quick Reference Guide 25
Compliance
Laser Safety
The PowerScan™ PM8500 handheld reader is a Class 1 LED product regarding its Illuminator and a Class 2 laser product regarding its Aiming System.
LED Illuminator
The use of an illuminator in the PowerScan™ PM8500 handheld reader is a Class
1 LED product:
ILLUMINATORE LED CLASSE 1
AUSLEUCHTER LED KLASSE 1
ILLUMINATEUR A LED DE CLASSE 1
ILUMINADOR LED DE CLASE 1
Aiming System
The PowerScan™ PM8500 aiming system meets the Class 2 requirements for laser safety.
I D F E
LA LUCE LASER È VIS-
IBILE ALL'OCCHIO
UMANO E VIENE
EMESSA DALLA FIN-
ESTRA INDICATA
NELLA FIGURA.
DIE LASER-STRAH-
LUNG IST FÜR DAS
MENSCHLICHE AUGE
SICHTBAR UND WIRD
AM STRAHLAUS
TRITTSFENSTER AUS-
GESENDET (SIEHE
BILD)
LE RAYON LASER
EST VISIBLE À L'OEIL
NU ET IL EST ÉMIS
PAR LA FENÊTRE
DÉSIGNÉE SUR
L'ILLUSTRATION
DANS LA FIGURE
A LUZ LÁSER ES
VISIBLE AL OJO
HUMANO Y ES
EMITIDA POR LA
VENTANA INDI-
CADA EN LA FIG-
URA.
LUCE LASER NON
FISSARE IL FASCIO
APPARECCHIO LASER
DI CLASSE 2 MAS-
SIMA POTENZA
D'USCITA:
LASERSTRAHLUNG
NICHT IN DEN
STRAHL BLICKEN
PRODUKT DER
LASERKLASSE 2
MAXIMALE AUS-
GANGSLEISTUNG:
RAYON LASER
EVITER DE
REGARDER LE
RAYON APPAREIL
LASER DE CLASSE 2
PUISSANCE DE
SORTIE:
RAYO LÁSER NO
MIRAR FIJO EL
RAYO APARATO
LÁSER DE CLASE
2 MÁXIMA
POTENCIA DE
SALIDA:
LUNGHEZZA
D'ONDA EMESSA:
CONFORME A EN
60825-1 (2001)
WELLENLÄGE:
ENTSPR. EN 60825-1
(2001)
LONGUEUR
D'ONDE EMISE:
CONFORME A EN
60825-1 (2001)
LONGITUD DE
ONDA EMITIDA:
CONFORME A EN
60825-1 (2001)
26 PowerScan™ M8500
Compliance
ENGLISH
The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your terminal.
STANDARD LASER SAFETY REGULATIONS
This product conforms to the applicable requirements of both CDRH 21 CFR
1040 and EN 60825-1 at the date of manufacture.
For installation, use and maintenance, it is not necessary to open the device.
Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light.
WARNING
The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
ITALIANO
Le seguenti informazioni vengono fornite dietro direttive delle autorità internazionali e si riferiscono all’uso corretto del terminale.
NORMATIVE STANDARD PER LA SICUREZZA LASER
Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione: CDRH 21 CFR 1040 e EN 60825-1.
Non si rende mai necessario aprire l’appa-recchio per motivi di installazione, utilizzo o manutenzione.
L'utilizzo di procedure o regolazioni differenti da quelle descritte nella documentazione può provocare un'esposizione pericolosa a luce laser visibile.
ATTENZIONE
Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni riportati dall’occhio umano in seguito ad una esposizione di breve durata, evitare di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente di luminosità intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore, anche attraverso superfici riflettenti come gli specchi.
DEUTSCH
Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal.
Quick Reference Guide 27
Compliance
NORM FÜR DIE LASERSICHERHEIT
Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und
CDRH 21 CFR 1040 Normen für die Lasersicherheit.
Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu öffnen.
Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschreiben werden, können ein gefährliches Laserlicht verursachen.
ACHTUNG
Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschäden von kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden für längere Zeit in den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die
Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, noch gegen reflektierende Oberflächen zu richten.
FRANÇAIS
Les informations suivantes sont fournies selon les règles fixées par les autorités internationales et se réfèrent à une correcte utilisation du terminal.
NORMES DE SECURITE LASER
Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de fabrication: CDRH 21 CFR 1040 et EN 60825-1.
Il n’est pas nécessaire d’ouvrir l’appareil pour l’installation, l’utilisation ou l’entretien.
L'utilisation de procédures ou réglages différents de ceux donnés ici peut entraîner une dangereuse exposition à lumière laser visible.
ATTENTION
Le produit utilise une diode laser. Aucun dommage aux yeux humains n’a été constaté à la suite d’une exposition au rayon laser. Eviter de regarder fixement le rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi de diriger le rayon vers les yeux d’un observateur, même à travers des surfaces réfléchissantes (miroirs, par exemple).
ESPAÑOL
Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal.
NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER
Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1.
28 PowerScan™ M8500
No es necesario abrir el aparato para la instalación, la utilización o la manutención.
Compliance
La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una exposición peligrosa a la luz láser visible.
ATENCIÓN
El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los ojos humanos a consecuencia de una exposición de corta duración. Eviten de mirar fijo el rayo láser así como evitarían cualquiera otra fuente de luminosidad intensa, por ejemplo el sol. Además, eviten de dirigir el rayo láser hacia los ojos de un observador, también a través de superficies reflectantes como los espejos.
The PowerScan™ PM8500 HandHeld Reader is not user-serviceable.
Opening the case of the unit can cause internal damage and will void the warranty.
CAUTION
CAUTION
La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una exposición peligrosa a la luz láser visible.
The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
Quick Reference Guide 29
Compliance
WEEE Compliance
Waste Electrical and Electronic Equipment (WEEE) Statement
English
For information about the disposal of Waste Electrical and Electronic
Equipment (WEEE), please refer to the website at www.scanning.datalogic.com.
Italian
Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
French
Pour toute information relative à l’élimination des déchets électroniques
(WEEE), veuillez consulter le site Internet www.scanning.datalogic.com.
German
Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten
(WEEE) erhalten Sie auf der Webseite www.scanning.datalogic.com.
Spanish
Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.scanning.datalogic.com.
Portuguese
Para informações sobre a disposição de Sucatagem de Equipamentos Eléctricos e Eletrônicos (WEEE - Waste Electrical and Electronic Equipment), consultar o site web www.scanning.datalogic.com.
Chinese
有关处理废弃电气电子设备 (WEEE) 的信息, 请参考 Datalogic
公司的网站: http://www.scanning.datalogic.com/。
Japanese
廃電気電子機器 (WEEE) の処理についての関連事項は Datalogic のサイト www.scanning.datalogic.com, をご参照下さい。
30 PowerScan™ M8500
Numeric Table
0
ANFOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKFHBHIK
AKCBPJCJGIIJCMCFGPOFMJLDJK
AEFBJLBGMHPKNIFGJCGBBDNHGK
AAPHBAJJDEBJCDJAGBDLGHNFHK
AFKEBJJPCPKMAJNAMBKKKCFJKK
DLDLLLDDDLLLLLLDLLDDDLDLLL
Numeric Table
1
ANEPGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALEHEEIK
AKCBPJCJGIIJCMCEHPLFIKNHNK
AEFBJLBGMHPKMKGPIEMNLKLEGK
AAPHBAJIDGFBMBLDDDNIEPNNFK
AEKEBJMNMOKOIOPNEFCOIJJLJK
DLDLLLDDLDDLLLLDDDLDDLDLLL
2
ANEOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKEFGHIK
AKCBPJCJGIIJCMCEGMILJPPDNK
AEFBJLBGMHPKMKEKGKAMOGNEGK
AELEBMKKGLEGCCHPLDIKICJLLK
DDLLLLDDDLDLLLLDLLLDDLDLLL
3
AMFPGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKECHEIK
AKCBPJCJGIIJCMCFGKLNLGILJK
AEFBJLBGMHPLNJDDOKGPBMIGGK
AAPHBAJIDCBNPBJGGNKINPEPFK
AGLEBMONMCIOAPCIABBMOFHJJK
DLLLLLDDLLLLLLLDLLLDDLDLDL
Quick Reference Guide
4
AMFOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALEAFHIK
AKCBPJCJGIIJCMCFHJIDKDKPJK
AEFBJLBGMHPLNJBGAEKOEAOGGK
AAPHBAJJDABBIJFONIOCLKDJDK
AGKEBJIKGHGGKDKKPHLIOOHJLK
DDDLLLDDDDLLLLLDDDLDDLDLDL
31
Numeric Table
5
AMEPGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKFAAEIK
AKCBPJCJGIIJCMCEGJNDOAMLNK
AEFBJLBGMHPLMLCPBCACOJIFGK
AAPHBAJIDCFJGLHNIKABJCDBBK
DDDLLLDDLLDLLLLDLLDDDLDLDL
6
AMEOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALFCCHIK
AKCBPJCJGIIJCMCEHKONPFOPNK
AEFBJLBGMHPLMLAKPMMDLFOFGK
AAPHBAJJDAFFBDLFDPELPHEHHK
DLLLLLDDDDDLLLLDDDDDDLDLDL
7
ANFNGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKFCHFIK
AKCBPJCJGIIJCMCEHJLAGJEHJK
AEFBJLBGMHPKMMHJBODNLMGFGK
AAPHBAJIDFBCOHNDCJGDNMAPDK
AHKEBNOMACIOMCLCEECKCIFKLK
DDLLLLDDDDLLLLLDDLLDDLDLDL
32
8
ANFMGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALFAFGIK
AKCBPJCJGIIJCMCEGKIOHMGDJK
AEFBJLBGMHPKMMFMPAPMOAAFGK
AAPHBAJJDHBOJPBLJMCJLJHJFK
AHLEBIILKHGGGODALCIOCDFKJK
DLDLLLDDLLLLLLLDLDLDDLDLDL
9
ANENGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKEAAFIK
AKCBPJCJGIIJCMCFHKNODPAHNK
AEFBJLBGMHPKNOGFOGFAEJGGGK
AAPHBAJIDFFGHNDIMOMKJBHBHK
AGLEBINJEGGEOJBNDGAKAIJIKK
DLDLLLDDDDDLLLLDDLDDDLDLDL
PowerScan™ M8500
NOTES
Numeric Table
Quick Reference Guide 33
Numeric Table
NOTES
34 PowerScan™ M8500
DECLARATION OF CONFORMITY
09
Datalogic Scanning Group Srl
Via S. Vitalino, 13
Lippo di Calderara di Reno (BO)
40012 Italy d ichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el
PowerScan Mxxx; Cordless Bar Code Reader e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
1999/5/EC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
ETSI EN 301 489-3 v1.4.1, August 2002 :E LECTROMAGNETIC COMPATIBILITY AND R ADIO SPECTRUM M ATTERS (ERM);
E LECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND
SERVICES ; P ART 3: S PECIFIC CONDITIONS FOR S HORT -R ANGE D EVICES (SRD)
OPERATING ON FREQUENCIES BETWEEN 9 K H Z AND 40GH Z
ETSI EN 300 220-3 v1.1.1, September
2000 :
E LECTROMAGNETIC COMPATIBILITY AND R ADIO SPECTRUM M ATTERS (ERM); S HORT
R ANGE D EVICES (SRD); R ADIO EQUIPMENT TO BE USED IN THE 25MH Z TO
1000MH Z FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500 M W; P ART
3: H ARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE
R&TTE D IRECTIVE
EN 60950-1, December 2001 :
Lippo di Calderara, April 20th, 2009
I NFORMATION TECHNOLOGY EQUIPMENT - S AFETY -
P ART 1 : G ENERAL R EQUIREMENTS
Ruggero Cacioppo
Quality Assurance Manager
Australia
Datalogic Scanning Pty Ltd
Telephone: [61] (2) 9870 3200 [email protected]
France and Benelux
Datalogic Scanning SAS
Telephone: [33].01.64.86.71.00
Germany
Datalogic Scanning GmbH
Telephone: 49 (0) 61 51/93 58-0 [email protected]
India
Datalogic Scanning India
Telephone: 91- 22 - 64504739 [email protected]
Italy
Datalogic Scanning SpA
Telephone: [39] (0) 39/62903.1
Japan
Datalogic Scanning KK
Telephone: 81 (0)3 3491 6761 [email protected]
Latin America
Datalogic Scanning, Inc
Telephone: (305) 742-2206 [email protected]
Singapore
Datalogic Scanning Singapore PTE LTD
Telephone: (65) 6435-1311 [email protected]
Iberia
Datalogic Scanning SAS Sucursal en
España
Telephone: 34 91 746 28 60 [email protected]
United Kingdom
Datalogic Scanning LTD
Telephone: 44 (0) 1582 464900 [email protected]
www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2009-2011 Datalogic Scanning, Inc. 820043014 (Rev B) July-2011
Download
Advertisement
Key features
OmniDirectional Operating
Decoding
Formatting and Concatenating
Autoscanning
Flash Memory
USA Driver License Parsing
Frequently asked questions
Place the PowerScan M8500 into the BC-80X0 cradle or the C-8000 battery charger. The battery is completely charged when the "Reader" LED on the cradle/battery charger turns green.
Connect the BC-80X0 cradle to the Host, charge the battery, read the Bind-Address label to pair the PowerScan M8500 to the BC-80X0 cradle and firmly position the reader onto the cradle.
The PowerScan M8500 has a range of 50 meters (164 feet) in open air for European models and 30 meters (98 feet) for USA models.