U-Line Echelon 2115RS00 User guide


Add to my manuals
20 Pages

advertisement

U-Line Echelon 2115RS00 User guide | Manualzz
QUICK START GUIDE
Ice Makers
•
115 V / 60 Hz & 220-240 V / 50 Hz
QUICK START GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain® Models, Beverage Centers, Clear Ice Machines,
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
SERVICE & PARTS ASSISTANCE
U-Line Corporation
Monday - Friday 8:00 am to 5:30 pm CST
8900 N. 55th Street
T: +1.800.779.2547
Milwaukee, Wisconsin 53223 USA
F: +1.414.354.5696
Monday - Friday 8:00 am to 4:30 pm CST
Service Email: [email protected]
T: +1.414.354.0300
Parts Email: [email protected]
F: +1.414.354.7905
Email: [email protected]
u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
QUICK START GUIDE
Contents
1
Model List
3
Safety and Warning
4
Environmental Requirements
5
Electrical
6
Water Hookup
9
Door Swing
10
General Installation
11
Integrated Panel Installation
13
First Use
14
Ice
14
Warranty
u-line.com
QUICK START GUIDE
u-line.com
Model List
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides
for all U-Line products.
Crescent Ice Makers
U-BI1215S-00A
U-BI1215INT-00A
U-BI1215B-00A
U-BI1215W-00A
ADA Series
U-BI95B-00A
U-BI98B-00A
U-ADA15IMS-00A
U-BI95W-00A
U-BI98W-00A
U-ADA15IMB-00A
Outdoor Series
U-BI1215SOD-00A
1
QUICK START GUIDE
u-line.com
Marine Series
ULN-BI95FCB-03A
ULN-WH95FC-03A
ULN-SS1095FC-03A
ULN-BI95FCB-20A
ULN-WH95FC-20A
ULN-SS1095FC-20A
ULN-SS1095FD-03A
ULN-SS1095FD-20A
ULN-SS1095NF-03A
ULN-SS1095NF-20A
ULN-SP18FCS-03A
ULN-SP18FCS-20A
ULN-SP18FCB-03A
ULN-SP18FCB-20A
ULN-SP18FCW-03A
ULN-SP18FCW-20A
ULN-SS98NF-03A
ULN-SS98NF-20A
Visit http://www.u-line.com/product-literature/userguides or
scan this QR code to view all user guides online.
2
QUICK START GUIDE
u-line.com
Safety and Warning
! DANGER
NOTICE
Do not use electrical appliances inside the food
PLEASE READ all instructions before installing,
storage compartment of this appliance.
operating, or servicing the appliance.
SAFETY ALERT DEFINITIONS
! WARNING
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
Keep ventilation openings in the appliance
enclosure or in the built in structure clear of
obstruction.
! DANGER
! WARNING
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
Do not store explosive substances such as
aerosol cans with flammable propellant in this
appliance.
! WARNING
! WARNING
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
Requirement for an external switch in the fixed
wiring is specified.
! CAUTION
! WARNING
Caution means that failure to follow this safety
statement may result in minor or moderate
Fix the appliance according to the instructions to
personal injury, property or equipment damage.
prevent instability.
GENERAL PRECAUTIONS
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience or knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure
that they do not play with this appliance.
3
QUICK START GUIDE
u-line.com
This appliance is intended to be used in household and
! CAUTION
similar applications such as:
Use care when moving and handling the unit.
• Staff kitchen areas in shops, office and other working
Use gloves to prevent personal injury from sharp
environments.
edges.
• Farm houses and by clients in hotels, motels and other
If your model requires defrosting, DO NOT use
residential type environments.
medical devices or other means to accelerate the
defrosting process. DO NOT use an ice pick or
• Bed and breakfast type environments.
other sharp instrument to help speed up
defrosting. These instruments can puncture the
inner lining or damage the cooling unit. DO NOT
• Catering and similar non-retail applications.
use any type of heater to defrost. Using a heater
to speed up defrosting can cause personal injury
and damage to the inner lining.
Environmental Requirements
NOTICE
115 V UNITS
Do not lift unit by door handle.
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
Never install or operate the unit behind closed
exposed to natural elements.
doors. Be sure front grille (plinth strip/base
fascia) is free of obstruction. Obstructing free
This unit is designed to operate between 50°F (10°C) and
airflow can cause the unit to malfunction and
100°F (38°C). Higher ambient temperatures may reduce
will void the warranty.
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
Failure to clean the condenser every six months
can cause the unit to malfunction. This could
For best performance, keep the unit out of direct sunlight
void the warranty.
and away from heat generating equipment.
Allow unit temperature to stabilize for 24 hours
In climates where high humidity and dew points are
before use.
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
Do not block any internal fans.
evaporate when the humidity drops.
Use only genuine U-Line replacement parts.
! CAUTION
Imitation parts can damage the unit, affect its
operation or performance and may void the
warranty.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
4
QUICK START GUIDE
u-line.com
220-240 V UNITS
! CAUTION
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
Damages caused by ambient temperatures of
exposed to natural elements.
40°F (4°C) or below are not covered by the
warranty.
This unit is designed to operate between 50°F (10°C) and
90°F (32°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
Electrical
115 V UNITS
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
! WARNING
In climates where high humidity and dew points are
SHOCK HAZARD — Electrical Grounding
present, condensation may appear on outside surfaces.
Required. Never attempt to repair or perform
This is considered normal. The condensation will
maintenance on the unit until the electricity has
evaporate when the humidity drops.
been disconnected.
Never remove the round grounding prong from
! CAUTION
the plug and never use a two-prong grounding
adapter.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
Altering, cutting or removing power cord,
warranty.
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
OUTDOOR UNITS
and will void the warranty.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
Never use an extension cord to connect power to
the unit’s ability to reach low temperatures and/or reduce
the unit.
ice production on applicable models.
Always keep your working area dry.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
NOTICE
In climates where high humidity and dew points are
Electrical installation must observe all state and
present, condensation may appear on outside surfaces.
local codes. This unit requires connection to a
This is considered normal. The condensation will
grounded (three-prong), polarized receptacle
evaporate when the humidity drops.
that has been placed by a qualified electrician.
5
QUICK START GUIDE
u-line.com
The unit requires a grounded and polarized 115 VAC,
The unit requires a grounded and polarized 230 VAC,
60 Hz, 15A power supply (normal household current). An
50 Hz, 8A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
to consult your local codes.
220-240 V UNITS
Water Hookup
! WARNING
FRONT MOUNTED VALVE
SHOCK HAZARD — Electrical Grounding
PREPARE PLUMBING
Required. Never attempt to repair or perform
The water valve in this unit uses a standard 1/4"
maintenance on the unit until the electricity has
(6.35 mm) compression fitting. U-Line recommends a
been disconnected.
braided stainless steel water supply line.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
! CAUTION
adapter.
Plumbing installation must observe all state and
Altering, cutting or removing power cord,
local codes. All water and drain connections
removing power plug, or direct wiring can cause
MUST BE made by a licensed/qualified plumbing
serious injury, fire, loss of property and/or life,
contractor. Failure to follow recommendations
and will void the warranty.
and instructions may result in damage and/or
harm.
Never use an extension cord to connect power to
the unit.
Water Supply Connection
When connecting the water supply, please note the
Always keep your working area dry.
following:
If the detachable type electric supply cord is damaged, it
• Before installing the unit and connecting to the cold
water supply, review the local plumbing codes.
must be replaced by an equivalent cord available from the
manufacturer or its service agent.
• The water pressure should be between 20 and 120 psi
(138 and 827 kPa).
NOTICE
Electrical installation must observe all state and
• The water line MUST have a shut-off valve in the
local codes. This unit requires connection to a
supply line.
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
6
QUICK START GUIDE
u-line.com
2. Remove the grille/access panel in the front and the
• The water line should be looped into 2 coils. This will
back panel.
allow the unit to be removed for cleaning and servicing.
Make certain that the tubing is not pinched or damaged
during installation.
3. Locate water
valve in the front
of the unit and
! WARNING
thread water
supply line
Connect to potable water supply only.
through.
NOTICE
! CAUTION
Route the water
supply line
Do not use any plastic water supply line. The line
through the unit
is under pressure at all times. Plastic may crack
so it does not come into contact with any
or rupture with age and cause damage to your
internal components other than the solenoid
home.
valve. Normal operation creates some vibration.
A water supply line contacting an internal
Do not use Teflon tape or joint compound on the
component or cabinet wall can cause excessive
water fitting. The rubber washer provides an
noise during operation or damage to the line.
adequate seal. Other materials could cause
blockage of the valve.
4. On the back panel,
break away filler feature
Failure to follow recommendations and
in bushing with flat
instructions may result in damage and/or harm,
screwdriver.
flooding or void the product warranty.
Remove
ZLWKɠDW
screwdriver
Use new hose set. Do not reuse old hose set.
5. Thread water line
! CAUTION
through back panel hole
(with bushing).
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
7
QUICK START GUIDE
u-line.com
• The water pressure should be between 20 and 120 psi
6. Turn on water supply and check for leaks.
(138 and 827 kPa).
7. Reinstall back panel and grille/front access panel.
• The water line MUST have a shut-off valve in the
supply line.
8. Install retaining clip.
• The water line should be looped into 2 coils. This will
allow the unit to be removed for cleaning and servicing.
Make certain that the tubing is not pinched or damaged
during installation.
! WARNING
Connect to potable water supply only.
! CAUTION
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack or
REAR MOUNTED VALVE
rupture with age and cause damage to your home.
PREPARE PLUMBING
The water valve in this unit uses a standard 1/4"
Do not use Teflon tape or joint compound on the
(6.35 mm) compression fitting. U-Line recommends a
water fitting. The rubber washer provides an
braided stainless steel water supply line.
adequate seal. Other materials could cause
blockage of the valve.
! CAUTION
Failure to follow recommendations and
instructions may result in damage and/or harm,
Plumbing installation must observe all state and
flooding or void the product warranty.
local codes. All water and drain connections
MUST BE made by a licensed/qualified plumbing
Use new hose set. Do not reuse old hose set.
contractor. Failure to follow recommendations
and instructions may result in damage and/or
harm.
! CAUTION
Water Supply Connection
Turn off water supply and disconnect electrical
When connecting the water supply, please note the
supply to unit prior to installation.
following:
Use caution when handling back panel. The
• Before installing the unit and connecting to the cold
edges could be sharp.
water supply, review the local plumbing codes.
8
QUICK START GUIDE
u-line.com
9. Install retaining clip.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the back panel.
3. Locate water valve inlet.
Door Swing
4. Break away filler feature
in bushing with flat
1200 SERIES
screwdriver.
Wall
Wall
1/4" Min.
(6 mm)
2-1/8" Min.
(54 mm)
Remove
ZLWKɠDW
screwdriver
5. Thread water line
through back panel hole
(with bushing).
6. Locate water valve inlet
90°
Door Swing
and connect to valve.
90°
Door Swing
7. Turn on water supply
and check for leaks.
Units have a zero clearance for the door to open 90°,
when installed adjacent to cabinets.
8. Reinstall back panel.
Stainless Steel and black and white models require 2-1/8"
(54 mm) door clearance to accommodate the handle if
installed next to a wall.
9
QUICK START GUIDE
u-line.com
General Installation
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
MARINE AND BI SERIES
knobs or pulls installed on the integrated panel/frame.
LEVELING INFORMATION
NOTICE
BI SERIES
Because these units do not have leveling legs, it
is extremely important that they sit on a level
surface. If they are not level, the ice mold will
1/4" Min. (6 mm)
not fill evenly.
Use a level to confirm
the unit is level. Level
should be placed along
top edge and side edge
90°
Door Swing
as shown.
All units have a zero clearance for the door to open 90°.
U-Line recommends a minimum door clearance of 1/4"
1
(6 mm) to accommodate the handle if the unit is installed
next to a wall.
INSTALLATION
MARINE SERIES
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
Wall
entangle the cord and water line.
3/4" (19 mm) Min.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments.
4. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
90°
Door Swing
All units have a zero clearance for the door to open 90°.
U-Line recommends a minimum door clearance of 3/4"
(19 mm) to accommodate the handle if the unit is
installed next to a wall or similar type of structure.
10
QUICK START GUIDE
u-line.com
1200 SERIES
INSTALLATION
LEVELING INFORMATION
1. Plug in the power/electrical cord.
1. Use a level to
confirm the unit is
2. Gently push the unit into position. Be careful not to
level. Level should
kink the water supply line or entangle the cord.
be placed along top
edge and side edge
3. Re-check the leveling, from front to back and side to
as shown.
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below
the countertop.
1
4. Install the anti-tip bracket.
5. Remove interior packing material and wipe out the
2. If the unit is not level, adjust the legs on the corners of
inside of the unit with a clean, water-dampened cloth.
the unit as necessary.
Integrated Panel Installation
MARINE AND BI95/BI98
This model accepts a 1/4" insert panel.
INSERT PANEL INSTALLATION
Turn to Adjust
Install the insert as follows:
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
! CAUTION
INSTALLATION TIP
Use care when handling the insert. Insert edges
If the room floor is higher than the floor in the cutout
may be sharp.
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Readjust the front legs to level the unit after it is
correctly positioned in the opening.
11
QUICK START GUIDE
u-line.com
8. Starting at the corners and working inward, push door
1. Remove top hinge screw pin
gasket into place on door.
with Phillips head screwdriver.
Remove door by tilting forward
and lifting off bottom hinge pin.
9. Place door on bottom hinge pin and install upper hinge
screw.
CRECENT ICE MAKERS AND ADA15IM
1. Fully open door/drawer.
2. Starting at corner, pull
2. Pull door gasket out of groove
gasket away from door/
(top edge of door only). Start in
drawer.
the middle and pull outward,
moving toward the edge. This
3. Continue to pull gasket
may take some force.
free from gasket channel.
4. Upon removal, lay gasket down on a flat surface.
3. Remove two outside screws
5. The panel should be aligned with the outside edge
holding door handle. Slightly
(opposite the hinge) and high enough to align with the
separate door handle from door.
highest point in the door/drawer.
4. Pull handle up and off.
Align Top Of Panel With Highest Point Of Door/Drawer
5. Slide custom door panel insert
into 1/4" (6 mm) channel in
Align Panel
Against
Door/Drawer
Edge First
door front.
NOTICE
Use care not to damage magnet, located on door
bottom when installing door insert. Do not set
door on bottom edge when pushing insert into
NOTICE
place.
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
6. Holding door gasket out of the way, replace handle on
flush with the top of the door/drawer.
door, making sure it is seated properly on insert and
that screw holes line up.
Panel
7. Install two small screws removed in Step 3.
12
Door
QUICK START GUIDE
6. Secure integrated
panel to door/drawer
u-line.com
11.Remove clamps from door/drawer.
Bar
Clamp
using clamps. A
NOTICE
robust tape may also
be used. U-Line
If panel requires additional adjustment after
recommends the use
removing clamps, slightly loosen each screw and
of bar clamps to
adjust panel as necessary. Tighten screws upon
Door/Drawer
completion.
secure the panel to
the door/drawer. If
using tape, be
Wood
Panel
12.Starting at the corners, re-install the gasket into the
certain the tape will
gasket channel in the frame. Make sure the gasket is
not damage panel
fully seated. This may take some force.
finish upon removal.
7. Using a 7/64" (3 mm)
drill bit, drill 6 pilot
Bar
Clamp
First Use
holes into the wood
All U-Line controls are preset at the factory. Initial startup
panel 1/2" (12 mm)
requires no adjustments.
deep using the holes in the door/drawer frame as a
guide.
NOTICE
U-Line recommends discarding the ice produced
NOTICE
during the first two to three hours of operation
It is important to ensure that all drilled holes are
to avoid possible dirt or scale that may dislodge
drilled to the correct depth in order to avoid
from the water line.
splits in the wood when hardwood is installed.
To turn the unit on or off:
8. Locate 6 of the #6x 1-1/4" (32 mm) screws provided
9. Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
ON
OFF
with your unit.
screws.
Press the rocker switch located inside the door on the
front panel, or behind the grille.
10.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
the channel.
Integrated Panel
Integrated Panel
13
QUICK START GUIDE
u-line.com
Ice
During periods of limited use or high ambient
ICE MAKER OPERATION
Gently shake the bucket to break apart cubes. If not using
When the ice bucket is full, the ice making mechanism will
the ice maker regularly, empty the ice bucket periodically
shut off. However, the refrigeration system will continue
to ensure fresh cubes.
temperatures, it is common for cubes to fuse together.
to cool and maintain the ice supply.
It is normal for cubes to appear cloudy. The cause is air
trapped in the water because of fast freezing. It is not
NOTICE
caused by the health, taste or chemical make up of the
Do not place cans or bottles in the ice
water. It is the same air that is in every glass of water you
compartment because they will freeze.
drink.
Remove the ice bucket for emptying and cleaning. To
OFF
remove the ice bucket, raise the bin arm and remove the
bucket from the ice compartment. Use the ice bucket for
ice storage only.
ON
Warranty
U-LINE CORPORATION LIMITED WARRANTY
USA AND CANADA
To turn off ice production: Raise the bin arm into
1. U-Line Corporation (“U-Line”) warrants each U-Line
an upright and locked position. The unit will preserve
product to be free from defects in materials and
temperature for ice storage.
workmanship for a period of one year (two years on
Modular 3000 Series) from the date of purchase.
NOTICE
U-Line further warrants the sealed system (consisting
of the compressor, condenser, evaporator, hot gas
If not intending to use the ice maker, turn the
bypass valve, dryer, and connecting tube) in each
water supply valve off. It is also important to
U-Line product to be free from defects in materials and
raise the bin arm of the ice maker (see above).
workmanship for a period of five years from the date of
Failure to raise the bin arm may result in damage
purchase.
to the water valve.
2. During the initial one year warranty period (two years
Certain sounds are normal during the unit’s operation. You
on Modular 3000 Series) for all U-Line products U-Line
may hear the compressor or fan motor, the water valve,
shall: (1) repair any product or replace any part of a
or ice dropping into the ice bucket.
product; and (2) for all Marine, RV and Domestic
U-Line products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line
! CAUTION
shall be responsible for the labor costs performed by a
U-Line authorized service company, incurred in
NEVER use an ice pick, knife or other sharp
connection with the replacement of any defective part.
instrument to separate cubes. Shake the ice
During years two through five of the warranty period
bucket instead.
for the sealed system, U-Line shall: (1) at U-Line’s
14
QUICK START GUIDE
u-line.com
option repair or replace any part of the sealed system;
under the terms of this warranty as a result of that
and (2) for all Marine, RV and Domestic U-Line
exposure. U-Line product may not be subjected to
products sold and serviced in the United States
temperatures below 40°F without following the
(including Alaska and Hawaii) and Canada, U-Line shall
winterization and vacation shutdown procedures in the
be responsible for the labor costs incurred in
user guide.
connection with the replacement of any defective part
of the sealed system. All other charges, including
6. U-Line’s Outdoor Limited Warranty, set forth in this
transportation charges for replacements under this
Paragraph 6, shall apply to U-Line models deemed
warranty and labor costs not specifically covered by
suitable for outdoor use by Underwriters Laboratory
this warranty, shall be the responsibility of the
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
purchaser. This warranty extends only to the original
website and/or on the serial tag located inside the
purchaser of the U-Line product. The Product
product.
Registration Card included with the product should be
promptly completed by you and mailed back to U-Line
A. Outdoor product may come into contact with rain by
or you can register on-line at www.u-lineservice.com.
virtue of outdoor use. Exposure to other sources of
water shall also cause this warranty to be void,
3. The warranty listed above does not apply to floor
including flooding of the area in proximity of the unit
display models. The warranty for these models shall
greater than 1/8" deep in water, hurricanes, splashing
be 30 days from the date of retail purchase and only if
of pool water, or directing a spray from a hose or
U-Line’s Product Registration Card included with the
similar device into and around the unit.
unit is completed and mailed back or electronically
submitted to U-Line. This 30 day warranty does not
7. If a product defect is discovered during the applicable
apply to cosmetic damages. A proof of purchase may
warranty period, you must promptly notify either
be required.
U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin
53223 USA or at +1.800.779.2547 or the dealer from
4. The following conditions are excluded from this limited
whom you purchased the product. In no event shall
warranty: use of cleaners other than the recommended
such notification be received later than 30 days after
stainless steel cleaners and U-Line Clear Ice Maker
the expiration of the applicable warranty period. U-Line
cleaner; installation charges; damages caused by
may require that defective parts be returned, at your
disasters or acts of God, such as fire, floods, wind and
expense, to U-Line’s factory in Milwaukee, Wisconsin,
lightning; damages incurred or resulting from shipping,
for inspection. Any action by you for breach of
improper installation, unauthorized modification, or
warranty must be commenced within one year after
misuse/abuse of the product; customer education
the applicable warranty period.
calls; food loss and spoilage; door and water level
adjustments (except during the first 30 days from the
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
date of installation); defrosting the product; adjusting
the controls; door reversal; and cleaning the
OTHER WARRANTIES, EXPRESS OR IMPLIED,
condenser.
INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
5. U-Line product are designed to operate in ambient
ARE DISCLAIMED. U-Line’s sole liability and your
temperatures between 50°F and 100°F unless
exclusive remedy under this warranty are set forth in
otherwise noted in the product manual. Exposure to
the paragraphs above. U-Line shall have no liability
temperatures outside this range may cause
whatsoever for any incidental, consequential or special
degradation of performance and issues such as lower
damages arising from the sale, use or installation of
ice production or spoiled contents that are not covered
15
QUICK START GUIDE
u-line.com
the product or from any other cause whatsoever,
apply to cosmetic damages. A proof of purchase may
whether based on warranty (express or implied) or
be required.
otherwise based on contract, tort or any other theory
of liability.
4. The following conditions are excluded from this limited
warranty: damage caused by outdoor use as these
units are not suitable for outdoor use; use of cleaners
Some states do not allow limitations on how long an
implied warranty lasts or the exclusion or limitation of
other than the recommended stainless steel cleaners
incidental or consequential damages, so the above
and U-Line Clear Ice Maker cleaner; installation
limitations may not apply to you. This warranty gives you
charges; damages caused by disasters or acts of God,
specific legal rights, and you may also have other rights
such as fire, floods, wind and lightning; damages
which vary from state to state.
incurred or resulting from shipping, improper
installation, unauthorized modification, or misuse/
abuse of the product; customer education calls; food
Warranty 6/2014 Rev.G
loss and spoilage; door and water level adjustments
(except during the first 30 days from the date of
U-LINE CORPORATION LIMITED WARRANTY
PRODUCTS OUTSIDE THE UNITED STATES AND
CANADA
installation); defrosting the product; adjusting the
controls; door reversal; and cleaning the condenser.
1. U-Line Corporation (“U-Line”) warrants each U-Line
5. U-Line product are designed to operate in ambient
product to be free from defects in materials and
workmanship for a period of two years from the date of
temperatures between 10°C and 32°C unless otherwise
purchase.
noted in the product manual. Exposure to
temperatures outside this range may cause
degradation of performance and issues such as lower
2. During the two year warranty period for all U-Line
ice production or spoiled contents that are not covered
products, U-Line shall be responsible for the labor
under the terms of this warranty as a result of that
costs performed by a U-Line authorized company,
exposure. U-Line product may not be subjected to
incurred in connection with the replacement of any
temperatures below 5°C without following the
defective part. All other charges, including
winterization and vacation shutdown procedures in the
transportation charges for replacements under this
user guide.
warranty and labor costs not specifically covered by
this warranty, shall be the responsibility of the
6. If a product defect is discovered during the applicable
purchaser. This warranty extends only to the original
purchaser of the U-Line product. The Product
warranty period, you must promptly notify your
Registration Card included with the product should be
country importer. For a country specific listing of
promptly completed and mailed back to U-Line or you
importers, please visit www.u-line.com/intl. In no
can register on-line at www.u-line.com. A proof of
event shall such notification be received later than 30
purchase may be required.
days after the expiration of the applicable warranty
period. U-Line may require that defective parts be
returned, at your expense, to the importer or directly
3. The warranty listed above does not apply to floor
to U-Line located in Milwaukee, Wisconsin, USA, for
display models. The warranty for these models shall be
inspection. Any action by you for breach of warranty
30 days from the date of retail purchase and only if
must be commenced within two years after the
U-Line’s Product Registration Card included with the
applicable warranty period.
unit is completed and mailed back or electronically
submitted to U-Line. The 30 day warranty does not
16
QUICK START GUIDE
u-line.com
7. If any applicable national law provides for a minimum
mandatory warranty period that is longer than the
aforementioned period of two years from the date of
purchase, such longer period shall apply.
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
ARE DISCLAIMED. U-Line’s sole liability and your
exclusive remedy under this warranty are set forth in
the paragraphs above. U-Line shall have no liability
whatsoever for any incidental, consequential or special
damages arising from the sale, use or installation of
the product or from any other cause whatsoever,
whether based on warranty (express or implied) or
otherwise based on contract, tort or any other theory
of liability.
Warranty 6/2014 Rev.H
Copyright © 2014 U-Line Corporation. All Rights Reserved.
Publication Number 30422 12/2014 Rev.B
17

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project