FOCUS

B Y : S H E R W O O D I N D U S T R I E S L T D

OWNER’S MANUAL

WHAT TO DO IF YOU SMELL GAS

• Open windows/extinguish any open flame.

• Do not try to light any appliance.

• Do not touch any electrical switch or use any phone in your building.

• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Massachusetts installations (Warning): This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.

Other Massachusetts code requirements: Flexible connector must not be longer than

36in., a shut off valve must be installed; only direct vent sealed combustion products are approved for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms containing gas fired direct vent appliances.

EG31-118

2

Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER,

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

• All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.

NOTE: Failure to follow these instructions could cause a malfunction of the fireplace, which could result in death, serious bodily injury, and/or property damage.

• Failure to follow these instructions may also void your fire insurance and/or warranty.

GENERAL

• Installation and repair should be done by a qualified service person. The appliance should be inspected before the first use and, at least, annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative the control compartments, burners and circulating air passageways of the appliance be kept clean.

• Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn or clothing ignition.

• Young children should be carefully supervised when in the same room as the appliance.

• Clothing or other flammable materials should not be placed on or near the appliance.

FOR YOUR SAFETY

• Installation and service must be performed by a qualified installer, service agency or gas supplier.

• This installation must conform to local codes or, in the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas

Code ANSI Z223.1.2 (USA)

• To prevent injury, do not allow anyone who is unfamiliar with the stove to operate it.

To prevent injury, if the pilot or pilot and burners have gone out on their own, open the glass door and wait 5 minutes to air out before attempting to re-light the stove.

• Always keep the area around these appliances clear of combustible material, gasoline and other flammable liquids and vapours.

• These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings/ decorations.

• Due to the paint curing on the stove, a faint odor and slight smoking will likely be noticed when the stove is first used. Open a window until the smoking stops.

Always connect this gas stove to a vent system and vent to the outside of the building envelope. Never vent to another room or inside the building. Make sure the specified vent pipe is used; properly sized and of adequate height to provide sufficient draft. Inspect the venting system annually for blockage and signs of deterioration.

WARNING: Failure to position the parts in accordance with the diagrams in this booklet, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

WARNING: Do not operate with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

• Never use solid fuels such as wood, paper, cardboard, coal, or any flammable liquids, etc., in this appliance.

• Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control or gas control systems that have been under water.

• Do not abuse the glass by striking it or slamming the door shut.

Table of Contents

Safety Precautions.....................................................................................................2

Table of Contents......................................................................................................3

Codes And Approvals.................................................................................................4

Specifications............................................................................................................5

Dimensions....................................................................................................5

Rating Label Location.....................................................................................5

Operating Instructions...............................................................................................6

Lighting Instructions.......................................................................................6

Adjusting Venturi Air Settings..........................................................................7

Blower speed.................................................................................................7

Normal Sounds During Operation.....................................................................7

Maintenance And Service...........................................................................................8

Routine Maintenance......................................................................................8

Glass Door Removal........................................................................................8

Cleaning The Glass.........................................................................................8

Cleaning The Firebox......................................................................................8

Replacing the Glass........................................................................................8

Maintaining Fascia And Surround Finishes........................................................9

Burner and Blower Removal............................................................................9

Fuel Conversion............................................................................................10

Initial Installation....................................................................................................12

Clearances to Combustibles...........................................................................12

B Vent Model................................................................................................12

Automatic Flue Gas Spill Switch.....................................................................12

Direct Vent Model.........................................................................................13

Direct Vent Restrictor Ring............................................................................13

Preparing Your Focus For Installation.............................................................13

Fan Controller & Burner Switch Installation.....................................................15

Converting A Direct Vent Fireplace To A B-Vented Fireplace..............................16

Converting A B-Vent Fireplace To A Direct Vented Fireplace..............................16

Venting Fireplace Inserts...............................................................................17

Electrical Requirements.................................................................................18

Gas Line Connection.....................................................................................19

Secondary Installation.............................................................................................20

Log Set and Ember Installation......................................................................20

Brick Panel Installation..................................................................................21

Trouble Shooting.....................................................................................................22

Parts List - Components...........................................................................................23

Parts Diagram - Body...............................................................................................25

Parts List - Surrounds & Fascia.................................................................................26

Parts Diagram - Surrounds & Fascia..........................................................................27

Parts List - Cast.......................................................................................................28

Parts Diagram- Cast Bay Front..................................................................................30

Warranty.................................................................................................................31

Installation Data Sheet.............................................................................................32

3

Codes And Approvals

DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit.

This appliance has been tested and approved for installations from 0 feet to 2000 (610 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000

(610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

• This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established

VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (FOCUS BV/DV; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO FOCUS Fireplace:

• Has been certified for use with either natural or propane gases. (See rating label.)

• Is not for use with solid fuels.

• Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall thermostat. IN

USA: see current ANSI Z223.1 for installation instructions.)

• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

• Is not approved for closet or recessed installations.

• Must have inner flat unit glass installed before bay window can be installed.

4

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

Specifications

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

D IMENSIONS :

30 5 /

16

" (77cm)

18" (45.7cm)

14 3 /

16

"

12 1 /

16

"

42" (106.7

18 15 /

16

" (48.1cm)

14 3 /

8

"

27 7 /

8

"

31 13 /

16

" (80.8cm)

Figure 1: Focus Exterior Dimensions.

R ATING L ABEL L OCATION :

The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace.

5

6

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY

RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.

L IGHTING I NSTRUCTIONS :

CAUTION:

Hot while operating. Do not touch, severe burns may result. Keep children, clothing, furniture, gasoline or other flammable vapors away.

CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A) This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly.

B) BEFORE LIGHTING smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.

C) Use only your hand to push in or turn the gas control knob;

NEVER use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D) Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above on this label.

2. Turn off all electrical power to this appliance.

3. Turn off the gas control knob clockwise to the off position.

4. Open door. Wait fIve (5) minutes to clear out any gas. Close door. If you smell gas STOP! Follow “B” in the above safety information. If you do not smell gas go to the next step.

5. Find pilot-located to the left under the front log. Turn the gas control knob counter-clockwise to “PILOT”. Push the gas control in fully and hold, keep knob depressed for about 30 seconds after the pilot is lit. Release knob. If pilot goes out, repeat steps 4 through 5.

WARNING: this gas valve has a lockout device, which will not allow the pilot burner to be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot does not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

6. Turn the gas control knob counter clockwise to the “ON” position. Flip the burner switch to “ON” THEN TURN THE “HI/LOW” knob to the desired setting.

7. Turn on the electrical power to the unit.

T OU

I

H

OF

F

P

O

N

O L I

1. Flip burner switch to “OFF”

2. Turn the gas control knob clockwise

TO TURN OFF GAS TO APPLIANCE

3. Turn off all electrical power to the appliance if service is to be performed.

to the “OFF” position.

�������

Figure 2. Lighting Instruction Label

Thermopile Thermocouple

Figure 4: Pilot Burning.

Figure 3: Gas Valve.

Operating Instructions

A DJUSTING V ENTURI A IR S ETTINGS :

There is only one (1) venturi and one (1) air shutter to be adjusted.

When installing the burner top, ensure that the venturi tube is engaged to the air shutter adjustment rod.

Use this small venturi adjustment rod to achieve a proper and efficient flame, shown in Figure 5.

Adjust rod until the flame pattern is similar to

Figure #.

Table 1: Venturi Setting.

Venturi Setting Rear

Natural Gas Propane

1 /

16

” min.

3 /

16

” min.

Move the rod located behind the piezo ignitor to increase or decrease primary air at the venturi tube.

Figure 5: Venturi Air Setting Rod

B LOWER SPEED :

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob

COUNTER CLOCKWISE until it “clicks” off.

It is advisable not to operate the blower below 1 /

3

speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

N ORMAL S OUNDS D URING O PERATION :

Component

Focus & Fascia

Burner

Temperature Sensor

Pilot Flame

Blower / Fan

Gas Control Valve

Table 2: Normal Sounds.

Sound & Reason

Creaking when heating up or cooling down.

Light pop or poof when turned off; this is more common with LP units.

Clinking when it senses to turn the blower on or off.

Quiet whisper while the pilot flame in on.

Air movement that increase and decreases with the speed of the blower. The blower is pushing the heat from the fireplace into the room.

Dull click when turning on or off, this is the valve opening and closing.

7

Maintenance And Service

R OUTINE M AINTENANCE :

At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips.

Warning: Clearances must be sufficient to allow access for maintenance and service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

The venting system must be periodically examined; it is recommended the examination is done by a qualified agency.

G LASS D OOR R EMOVAL :

Turn unit off and wait until the appliance has cooled down.

Remove the decorative fascia or clip-on bay window by lifting it up and removing it from the slots in the body of the unit.

Undo the two (2) 5 /

16

’’ bolts at the top of the door frame and then lift the glass and frame, being careful that the glass does not fall out of the door frame assembly. Install in the reverse order.

Ensure the door is properly fastened after cleaning before attempting to re-light the appliance.

Figure 6: Top bolts for glass door.

C LEANING T HE G LASS :

When the fireplace has cooled, remove the face of the fireplace along with the glass. See M

AINTENANCE

A

ND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

. Check the gasket material on the back of the glass, making sure that it is attached and intact.

During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all fireplaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave a slight film behind the glass, a temporary problem. The glass will need cleaning about two weeks after installation. Use a mild glass cleaner and a soft cloth; abrasive

cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass should require cleaning no more than two or three times a season. Do not clean the glass when it is hot.

C LEANING T HE F IREBOX :

Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and place on a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers as in the

S ECONDARY I NSTALLATION - L OG S ET AND E MBER I NSTALLATION section. If new/more embers and rock wool are required, contact your nearest ENVIRO dealer.

8

R EPLACING THE G LASS :

The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P ARTS L IST ). Wear gloves when handling damaged glass door assembly

Maintenance And Service

to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.

M AINTAINING F ASCIA A ND S URROUND F INISHES :

When a plated surround or face is received, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. If your fingers come into contact with the finishes, the oils left as fingerprints on the plating can become permanently etched in the surface. To prevent this, clean the painted surfaced with a damp cloth and clean plated finishes with denatured alcohol after the installation and prior to first firing of the fireplace. If your fingers come into contact with the antique copper finish, the oils left as fingerprints on the copper can cause discoloration, which will eventually turn green in that area. You can clean the patina or discolored areas of the antique copper finish with “OO” 3M green sanding pads. These can be purchased from most hardware stores. On the areas with discoloration, use the sanding pads to sand in the same direction as the brushed finish, then blend the finish by feathering in the surrounding area. This refinishing procedure has been approved by the manufacturer and will not harm the finish. Please note: ANTIQUE COPPER IS THE ONLY FINISH

THAT CAN BE SANDED, DO NOT SAND PEWTER, GOLD OR NICKEL FINISHES.

B URNER AND B LOWER R EMOVAL :

1. Turn the unit off, remove the glass door (see M

AINTENANCE

A

ND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

) and the log set. Caution: Bleed lines before lighting and light pilot with door open.

2. Remove the burner tray top by removing the two (2) T-20 screws located in the center of the burner tray (see Figure 7). Slide tray to the left and lift out.

3. Remove brick panels (see S ECONDARY I NSTALLATION - B RICK P ANELS I NSTALLATION ).

4. Remove the surround panel by lifting it straight up and then out to free it from the body of the unit.

5. Turn the gas supply off and remove gas connection and disconnect the wiring from the side of the appliance.

6. Remove the three (3) T-20 screws that hold the air deflector in place on the back firewall (see Figure 7) and undo the remaining screws that hold the burner assembly in the appliance. Carefully remove the gas tray assembly from the firebox, ensuring that wires and gas lines are not damaged.

Air deflector

Gas and electrical tray complete

7. Remove the blower and housing from the gas tray assembly by removing the fastening screws located on the back of the gas tray assembly.

Disconnect the wiring from the fan temperature sensor and remove.

Burner top

To install; follow steps 1 through 7 in reverse. Perform a gas leak check on all gas line with a soap and water solution or an approved method and check burner and blower assembly for proper operation.

Figure 7: Removing Burner and Gas Tray.

9

Maintenance And Service

F UEL C ONVERSION :

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing.

10

Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

Kit Parts List:

1 - Orifice (NG #38 DMS or LP #52 DMS)

1 - Pilot Injector (NG 0.62 mm; LP 0.35 mm)

1 - Installation instruction sheet

1 - Conversion label

Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are missing, contact your dealer, distributor or courier company to have them replaced before starting this installation.

Conversion Kit Installation:

1. Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow the valve and unit to cool down to room temperature.

2. Remove the glass as shown in the M

AINTENANCE AND

S

ERVICE

- O

PENING

T

HE

D

OOR

.

3. Carefully remove the log set and ember material if they are installed.

4. Remove the burner as shown in the M

AINTENANCE AND

S

ERVICE

- B

URNER

R

EMOVAL

.

5. Convert the burner orifice(s): a) Remove the main burner orifice with a 1⁄2 inch deep socket.

b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow. c) Install the new orifice(s) from the kit into the brass elbow.

6. Convert the pilot injector: a) Pull the pilot hood straight up to access the pilot injector. b) Using a 5 /

32

” or 4 mm Allen key, remove the pilot injector.

c) Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key, d) Reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place.

Figure 8: Removing valve cap.

Maintenance And Service

7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 8.

b) Insert a 5 /

32

” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 9), rotate it counter-clockwise until it is free and extract it.

Tighten

Loosen

Figure 9: Removing valve screw.

c) Check that the screw is clean and if necessary remove dirt.

d) Flip the screw (refer to Figure 10).

e) Using the Allen wrench as shown in Figure 9, rotate the screw clockwise until a torque of 9 inch lbs. WARNING! Do not over tighten the screw.

It is recommended that you grip the wrench by the short side.

f) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red oring visible (refer to Figure 11). If the conversion is from LPG to NG, the red o-ring of the screw must be not visible.

Figure 10: Flip valve screw.

g) Re-attach the black protection cap that was removed in step a

(Figure 8).

Red o-ring is visible

Red o-ring is not visible

8. Reinstall the burner, brick panels, log set, embers, and glass door. Also refer to S

ECONDARY

I

NSTALLATION

-

I NSTALLING L OG S ET AND E MBERS . When re-installing the burner, ensure that the burner to pilot hood relationship

LPG Configuration

Figure 11: O-ring on valve screw.

is similar to what is shown in Figure 12. On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube

9. Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the unit.

10. Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE

AN OPEN FLAME WHEN TESTING FOR LEAKS.

11. Reconnect the electrical power to the unit.

Figure 12: Burner to pilot hood relationship.

12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation and proper flame appearance. Also refer to S

ECONDARY

I

NSTALLATION

- L

OG

S

ET AND

E

MBERS

I

NSTALLATION

for a flame appearance picture.

13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the unit has been converted to a different fuel type.

11

Initial Installation

12

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

C LEARANCES TO C OMBUSTIBLES :

Mantle pillar to glass door

From floor to 8” wide mantle

Minimum non-combustible surface in front of unit 11” (27.9 cm)

Warning: Clearances must be sufficient to allow access for operation, maintenance and service. Stove must sit on a non-combustible surface.

9” (22.8 cm)

38” (96.5 cm)

Depth of unit into fireplace 16” (41 cm)

Depth of unit out of fireplace 3’’ (7.6 cm)

Minimum fireplace size: Width 34” (86.36 cm)

Height 21” (53.3 cm)

Depth 18” (45.7 cm)

B V ENT M ODEL :

WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations, either through poor venting or by overheating. It is important that this unit has sufficient air circulation for proper venting and combustion. Provisions must be made for the supply of adequate combustion and ventilation air.

These openings must not be blocked. The appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.

A UTOMATIC F LUE G AS S PILL S WITCH :

NOTE: This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system designed to protect against improper venting of combustion products. This safety switch is located on the rear of the appliance close to the draft hood relief opening. If the switch trips more than once, the venting should be inspected by a qualified service technician for possible blockage or severe down draft conditions.

BV Only: The draft hood must be in the same pressure zone as the air inlet. To inspect draft from the front of the unit, locate the 1⁄4” tube between the louvers (see Figure 13) and check for a draft using smoke. A vacuum or suction into the tube will indicate proper drafting.

This model can be vented with 4” aluminum or stainless steel flex vent and/or certified Type B Gas

Vent. The flue collar of the appliance will fit inside of a standard 4” vent and may be fastened directly to the vent, check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation.

Figure 13: Draft Check.

Check draft with a match or smoke in a 1⁄4" (6 mm) tube located here.

Initial Installation

QUALIFIED INSTALLERS ONLY

D IRECT V ENT M ODEL :

WARNING: This appliance has been designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations.

This model is vented with TWO (2) 3” aluminum or stainless steel flex vent leading into a co-linear to coaxial vent adaptor and using a Simpson Dura Vent vertical termination cap. The flue collars of this model will fit inside of standard 3” vent and may be fastened directly to the vent. The Exhaust vent is in the center of the flue connector. The Air Intake is on the left side of the vent collar plate (this outlet is not in the center it is off to one side of the vent collar plate.)

Check periodically that the vents are unrestricted. Also ensure that all direct vent pipes have been properly sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must be installed in the correct locations on the removable draft hood connector.

D IRECT V ENT R ESTRICTOR R ING :

DIRECT VENT ONLY: The maximum vertical vent height for a direct vent installation is 25 feet (7.62 m).

Use the vent restrictor ring for installations above 15 feet (4.57 m). See Figure 14 for installation of restrictor ring.

Vent Restrictor Ring

Figure 14: Direct vent restrictor ring installation.

P REPARING Y OUR F OCUS F OR I NSTALLATION :

1. Remove the appliance and surround panels from the packaging; check to make sure there is no damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found, please report it to both the courier and your dealer as soon as possible.

2. Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury.

3. Remove the glass door; see M AINTENANCE A ND S ERVICE - G LASS D OOR R EMOVAL .

4. Remove log and ember set and all wrapping material from inside the stove. Remove wrapping material from log and embers and check for any damage. If damage is observed, do not use unit and contact your local dealer.

5. Remove the vent collar plate from the top of the stove by unscrewing the two (2) T-20 Torx screws located on the center top of the stove. Slide collar plate backwards. Properly secure the vent collar plate to the flexible vent pipe liner(s) previously installed in the chimney. Be careful not to over-stretch the liner(s).

13

14

Initial Installation

6. Install the leveling legs. Thread the two (2) 5”

(13 cm) bolts and locknut up into the captive nuts at each end of the leveling leg bracket (refer to

Figure 15).

7. Place the unit part way into the fireplace.

Connect the fireplace insert’s flexible gas line to the household gas supply, using locally approved methods. Place the electric cable so it can be connected to the power supply.

Leveling legs bracket

Figure 15: Installation of Leveling Legs.

Surround Panel

Figure 16: Corner brackets for trim.

Figure 17: Two pieces of corner bracket.

8. As you push the unit into its final position in the fireplace, reinstall the vent collar plate to the stove by sliding it along the draft hood and secure with the screw. Adjust the leveling legs to ensure the unit is level.

8. The trim set for your surround panel, must be installed before installing the surround panel onto the unit. a) Attach one side trim to the top trim using a corner bracket

(see Figure 16) to secure pieces together. There are two

(2) main pieces to each corner bracket (see Figure 17).

When installing the corner pieces into the trim the “B

FACE” sides must face each other and the screw heads are to face out. With the bracket in place and the top and a side trim snug together use a flat head screwdriver to turn the two (2) screws in the bracket in to tighten it into the trim.

b) Slide the two (2) attached trim pieces onto the surround panel.

c) Attach the other side trim piece to the top trim using the same method used in Step a.

d) Place the second side of the trim on the surround panel in the same manner use on the first side and secure in the same manner.

#8 screw

Side

Trim e) On the side trims there are holes

2” (50 mm) from either end.

Using a Phillips screwdriver to place a #8 screw 11⁄4” long in each hole and tighten (refer to

Figure 18). This will keep the trim tight against the surround.

NOTE: The notch at the bottom of the left trim is so the power cord can be run to the outside of the panel.

Surround Panel

Figure 18: Screw to hold the trim against the surround.

Initial Installation

QUALIFIED INSTALLERS ONLY

10. Connect the wires from the unit to the ON/OFF/

THERMOSTAT switch and the FAN CONTROLLER (see

I NITIAL I NSTALLATION - E LECTRICAL R EQUIREMENTS ).

11. Place the assembled surround panel around the stove, align the slots. Push back then down to engage the surround panel hooks with the slots in the fireplace. Install the decorative fascia or bay window options to the appliance by aligning the hooks and the slots in the fireplace as seen in the surround panel installation.

Figure 19: Surround Panel installation.

F AN C ONTROLLER & B URNER S WITCH I NSTALLATION :

The fan controller and burner switch may be installed in one of three places. Keep the wires away from the bottom of the firebox or any other hot surfaces.

Option 1 - Unit Panel, Cast Iron Faceplate, Bay Door

Assembly, or Custom Surround Panel.

The fan controller and burner switch are to be installed into the Focus’ control panel (see Figure 20). Remove the knob and screw from the fan controller and place the fan controller through the round hole in the control panel from the back. Tighten nut onto fan controller from the front of control panel and push on the knob. The burner switch is just pushed into place from the front of the control panel.

Route the wiring harness as shown in Figure 20.

Option 2 - Standard Surround Panel.

A

Wiring harness

Fan controller location

Burner switch location

Figure 20: Component placement.

The standard surround panel comes with a fan controller and burner switch so the set that comes with the unit panel can be kept as spare parts. The fan controller comes pre-mounted in the surround panel and burner switch is pressed into a notch in the trim. Route the wiring harness through the hole in the side of the unit marked with an “A” in Figure 20.

Option 3 - Cast Iron Faceplate or Bay Door Assembly.

The fan controller is to be installed into the Focus’ control panel but the burner switch can be installed into the fascia (see Figure 20). To accomplish this, cut one wire tie so that the wires can be properly routed. Place the orange and white wires through through the hole in the side of the unit, marked with an “A” in Figure 20, then along behind the front edge of the fireplace bottom to the control panel. Use the wire ties provide to bundle and secure wire. Remove the knob and screw from the fan controller and place the fan controller through the round hole in the control panel from the back. Tighten nut onto fan controller from the front of control panel and push on the knob. The burner switch is pressed into a notch on the edge of the fascia.

15

16

Initial Installation

QUALIFIED INSTALLERS ONLY

C ONVERTING A D IRECT V ENT F IREPLACE T O A B-V ENTED F IREPLACE :

Parts required for conversion

1 - 300°F (149°C) manual reset spill switch and wires

1 - Drafthood (4’’ chimney connection)

2 - Air channels

1 - Drafthood diverter

300°F (140°F)

Spill Switch

1. Remove the chimney connector, fresh air cover plates and draft hood cover plate.

2. Install the 300°F (149°C) spill switch in the location provided.

3. Install the two fresh air channels in the correct locations.

Drafthood

Diverter

Chimney

Connector

Air Channels (x2)

4. Install a new 4’’ chimney liner into the Figure 21: Converting To A BV Fireplace.

existing and attach with three (3) sheet metal screws evenly spaced to new 4’’ chimney connector.

5. Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production causing personal injury or property damage.

C ONVERTING A B-V ENT F IREPLACE T O A D IRECT V ENTED F IREPLACE :

Drafthood

Cover Plate

Chimney

Connector

Air Channel

Cover Plate (x2)

Figure 22: Converting To A DV Fireplace.

Parts required for conversion

1 - Drafthood (2 - 3’’ dual pipe chimney connector)

2 - Air channel cover plates

1 - Drafthood cover plate.

1. Remove the chimney connector, 300° spill switch, two (2) B-vent air channels and Bvent draft diverter plate.

2. Install the two (2) air channel cover plates in the locations provided.

3. Install the draft hood cover plate in the location provided.

4. Install two (2) 3’’ chimney liners in the existing chimney, securing the 3’’ liners with three (3) sheet metal screws evenly spaced to the new chimney connector.

5. Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production causing personal or property damage.

Initial Installation

QUALIFIED INSTALLERS ONLY

V ENTING F IREPLACE I NSERTS :

The ENVIRO FOCUS may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials.

An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s instructions which accompany the chimney liner kit.

Remove the vent collar plate from the top of the insert and connect it securely with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point.

IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.

�� �����

Install sealed throat connector or flashing to prevent leakage of room air up through chimney.

DV Only: Before installing vent liners, mark each liner on both ends to designate which is the intake and the exhaust.

Measure the height of the chimney before hand and purchase the appropriate kit. Never attempt to over-stretch a flexible liner to accommodate the height of the chimney.

Any flue damper must be removed or blocked permanently in the open position.

The chimney must be clean, in good working order and constructed of non-combustible materials.

Make sure that all chimney cleanouts are tightly fitting and will not permit air to leak into the chimney

Figure 23: Installation of Focus DV and BV.

�� �����

17

18

Initial Installation

QUALIFIED INSTALLERS ONLY

E LECTRICAL R EQUIREMENTS :

The Focus will operate without electrical power. This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners. This appliance when equipped with a blower, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1

CANADIAN ELECTRICAL CODE Part 1, SAFETY

STANDARDS FOR ELECTRICAL INSTALLATIONS,

OR THE NATIONAL ELECTRICAL CODE ANSI /

NFPA 70 in the U.S.

WARNING: Electrical grounding instructions.

This appliance is equipped with a three-prong

(grounding) plug for your protection against shock hazard, and should be plugged directly into a properly grounded three-prong outlet.

DO NOT cut or remove the grounding prong from this plug.

Figure 24: Focus Wiring Diagram.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

70 ° F

ON

OF

F

70 ° F

UP

DOWN

COOL / HEAT

PROGRAM

Optional

Remote

Control

Purple

Grey

ON/OFF/REMOTE

Thermostat Switch

Blue

Thermocouple

Thermopile

Manifold

Pressure

Tap

Inlet

Pressure

Tap

Gas

Control

Valve

Optional

Wall Switch

Pilot

Adjustment

Screw

Optional

Thermostat

Figure 25: Wiring of a Thermostat.

Table 3. Recommended Thermostat

Wire Size.

Wire Size

14 gauge

16 gauge

18 gauge

20 gauge

22 gauge

Max. Length

100 ft (30.48 m)

60 ft (18.29 m)

40 ft (12.00 m)

25 ft (7.62 m)

18 ft (5.49 m)

Initial Installation

QUALIFIED INSTALLERS ONLY

G AS L INE C ONNECTION :

Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

Gas Line Connection:

•This fireplace is equipped with a certified flexible pipe located on the right side of the unit, terminating in a 3⁄8” male NPT fitting. Consult the local authorities for local codes or use the CAN/CGA B149 (1 or 2) installation code in Canada. In the US, gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.

•The efficiency of this unit is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

T O L I

P

I

H

��������

�������� ���

LO

T OU IN

OF F

P

O N

�����

�������� ���

����� ����������

�����

������

����

��� �������

����

Figure 26: Fully Labeled Gas Valve.

The appliance and its’ shut-off valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 psig (3.45 KPa) or the valve will be damaged.

The unit must be isolated from the gas supply piping system by closing its’ individual manual shut off valve during any pressure testing of the gas supply piping system at pressures equal to or less than

1⁄2 psig (3.45 KPa).

Always check for gas leaks with a soap and water solution after completing the required pressure test.

TO TEST VALVE PRESSURES:

The pressure taps are located on the top right of the valve.

• Turn set screw 1 turn counterclockwise to loosen.

• Place 5/16 in (8 mm) I.D. hose over the pressure taps.

• Check pressures using a manometer.

• When finished, release pressure, remove hose and tighten set screw.

Table 4: Pressure and BTU Information.

Main Burner

Orifice:

Manifold Press:

Min. Manifold Press: 1.1 / 0.27

Max. Supply Press: 7.0 / 1.74

Min. Supply Press: 5.0 / 1.24

Max. BTU Input:

Min. BTU Input:

Natural Gas

(in W.C./KPa)

#38 DMS

3.8 / 0.95

Propane Gas

(in W.C./KPa)

#52 DMS

11.0 / 2.74

2.7 / 0.67

13.0 / 3.28

12.0 / 2.98

30,000/ 8.8 KW∙h 28,500/ 8.2 KW∙h

15,000/ 4.4 KW∙h 14,000/ 4.1 KW∙h

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

19

Secondary Installation

20

L OG S ET AND E MBER I NSTALLATION :

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner comes with placement pins and rest areas, which make alignment easier. Using Figures 27 to 31, carefully set the logs in place.

Back Placement/Support Pins

NOTE: The logs are fragile and should be handled with care.

Place the rear log on the two back placement pins.

Install the left front log on the left placement pin with the narrow end of the log resting on the rectangular rest area.

Figure 27: Focus burner.

Install the right front log on the right placement pin with the narrow end of the log resting on the rectangular rest area. The last two logs should meet tip to tip on the rest area.

One end of the big log twig will rest on the pin on the right log and the other will lay within the left rest area.

The small log twig should be placed so it sit completely within the right rest area.

Once the logs are in place the embers can be placed lightly between the logs. Bags of ceramic fiber embers and rock wool are provided. The ceramic fiber comes in chunks that are about 2”-4” (5-10cm) long.

Break these roughly in half and place them irregularly around the burner. When there is a sparse but even layer of embers, spread the rock wool in the same manner. DO

NOT pack this ember material as this could create an unsafe condition.

The pieces should be lightly place so they don’t completely block any of the tiny ports. DO NOT allow any of the embers to rest against the pilot assembly.

Figure 28: Focus Log Placement 1.

Figure 29: Focus Log Placement 2.

Figure 30: Focus Log Placement 3.

Secondary Installation

Caution: Use only the type of ember material supplied with this fireplace. Due to the irregular size of the ember material, there may be more than required. Use of other foreign materials on the burners may create dangerous conditions.

If over time, through cleaning and servicing, these embers require replacement , contact your nearest

Enviro dealer.

IMPORTANT: Upon the first light up after installing logs and embers, watch for ignition to ALL burner ports. If a long delay is noted wait for the appliance to cool down:

• Open the front door of the appliance

• Carefully reposition the embers, making sure that the burner ports are not plugged or blocked.

Figure 31: Focus Log Placement Complete.

Figure 32: Focus Log Set Burning.

B RICK P ANEL I NSTALLATION :

Remove the glass door and the log set. Remove the burner tray by undoing the hold-down screws located in the center of the pan burner and sliding the assembly to the left, then up.

Gently pull right brick side panel inward from the bottom back. Pull towards the back then out, freeing it from the front retainer.

Caution: The pilot may damage panel. Remove left side panel in the same fashion.

To install, insert front edge of brick panel into the retainer and very gently move panel forward and out until flush against firebox side.

Figure 33: Brick Panel Installation.

21

22

Trouble Shooting

Problem

The main burner does not ignite when called for.

Spark will not light the pilot after repeatedly pressing the spark ignitor.

Pilot will not remain lit.

Possible Cause Solution

The gas valve may not be on.

• Check that the gas control knob is in the “ON” position.

Thermostat is not calling for heat.

Problem with gas valve.

• Adjust the thermostat several degrees above ambient temperature.

• Use a DC voltmeter to measure the voltage across the TPTH and

TP terminals. Main operator voltage: Open circuit ≥ 325mV Closed circuit ≥ 100mV

• If voltage is not present, check the control circuit for proper operation.

• If proper control system voltage is present, replace the gas control.

Defective piezo ignitor.

Broken spark electrode.

Misaligned spark electrode.

Problem with thermocouple circuit.

• Check connections to ignitor.

• If ignitor connections are good but no spark, replace ignitor.

• Check for broken ceramic insulation, replace electrode if broken.

• If spark is not arcing from electrode to pilot, loosen the screws on the pilot base adjust and tighten.

• Check for proper connection of the thermocouple to the rear of the valve. If loose, fully tighten.

• Check pilot for full flame impingement around thermocouple. If flame is too small, check gas pressure, adjust pilot rate screw, check pilot head for damage.

• Check thermocouple voltage at valve. It must be greater than 5 mV.

If low, replace thermocouple.

Burners will not remain lit.

Flame lifting

Glass fogs up

Blue Flames

Flames are burning “dirty” or sooting

Remote control doesn’t work

BV ONLY:

Insufficient air for combustion

Air in gas line (pilot dies while knob is depressed).

Problem with thermopile circuit.

Leak in vent pipe

Improper vent configuration

Terminal may be recirculating flue gases

• Check for leaks in vent connections.

• Check vent configuration with manual.

• Check to see if terminal is on correctly.

• May need to install high wind termination cap.

• Contact dealer.

Normal Condition: after the appliance warms up the glass will clear.

**Due to additives in gas, glass may get hazy during operation** Clean as needed.

Normal during start up: flames will yellow as the fireplace heats up.

Flame impingement

• Bleed line.

• Check gas line pressure.

• Contact dealer.

• Check gas line pressure .

• Check for flame impingement on thermopile. If low, see “Pilot will not remain lit”.

• Check thermopile for minimum of 300 mV when burner is switched on.

• Check wiring to thermostat for breaks.

BV ONLY: Check for spillage at draft hood that may trip spill switch

Problem with the remote

Problem with fireplace

• Air tight house.

• A vacuum in room due to other air-moving device.

• Check log positioning.

• Increase primary air by opening the venturi shutter and/or by opening the vent restrictor.

See also “Burners will not remain lit.”

• One or more of the batteries are dead. See remote control instructions.

• The on/off switch is turned to OFF.

• The gas control valve is turned to PILOT or OFF.

• The pilot has gone out.

• Supply make up air to the unit.

Parts List - Components

Reference Number

1

2

3

3

3

3

3

3

3

3

4

5

6

6

7

8

8

9

Part Description

120°F (49°C) Ceramic Fan Temperature Sensor

300°F (149°C) Spill Switch

Thermocouple

Spark Electrode with Ignitor Cable

Thermopile

Fully Assembled Pilot NG

Fully Assembled Pilot LP

Pilot Orifice NG Threaded

Pilot Orifice LP Threaded

Pilot Gasket

S.I.T. Piezo Ignitor

Stainless Steel Flex Connector with 3⁄8” Elbow 18” Long

FPI Burner Switch

FPI Fan Controller - 115 V

FPI Fan Controller Knob

Domestic Power Cord - 115 V

Heyco Strain Relief

Embers (Coal & Wool)

Convection Blower - 115 V

Burner Control Assembly NG

Burner Control Assembly LP

Burner Switch Bracket

Relief Door Gasket

Window Channel Tape (6 feet)

1 Piece Glass With Tape (6 feet)

Part Number

EC-001

EC-003

EC-009

EC-011

EC-012

EC-015

EC-016

EC-019

EC-020

EC-021

EC-023

EC-024

EC-026

EC-039

EC-041

EC-042

EC-044

EC-046

EC-069

EG31-052

EG31-053

EG31-075

EG31-087

EG31-089

EG31-090

23

24

Parts List - Components

Reference Number

10

11

12

13

14

15

16

17

Part Description

Door Only - Painted

Venturi

Owner’s Manual

3⁄8” NTP Male 3⁄8 Comp. 90° Elbow

1⁄4” NTP Female 3⁄8 Comp. 90° Elbow

LP to NG Conversion Kit

NG to LP Conversion Kit

Conversion Kit BV to DV

Conversion Kit DV to BV

Extension Knob (Pilot)

Extension Knob (HI-LO)

Relief Door & Gasket

Blank Orifice #73

BV Flue Collar Gasket

DV Flue Collar Gasket

Log Set & Embers

Ceramic Brick Liner

Dual Bulb Door Gasket (10 feet)

Pan Burner

S.I.T. Nova Valve Convertible

Focus Conversion Kit LP to NG Convertible

Focus Conversion Kit NG to LP Convertible

S.I.T. Valve Conversion Screw With O-Ring

S.I.T. Valve Conversion Screw Cap

30-034

50-343

50-528

50-529

50-588

50-610

50-634

50-897

50-1421

50-1434

50-1435

50-1450

50-1451

Part Number

EG31-092

EG31-099

EG31-118

EG31-124

EG31-125

EG31-200

EG31-202

EG31-205

EG31-206

30-030

30-031

Parts Diagram - Body

25

26

Parts List - Surrounds & Fascia

Reference Number

18

18

18

18

19

19

20

20

20

21

21

21

Part Description

Steel Bay Face - Polished Nickel

Steel Bay Face With Glass - Painted

Steel Bay Cover - Gold

Steel Bay Cover - Polished Nickel

Steel Bay Cover - Painted

Steel Bay 3 Pieces Glass Set with Tape

Standard Surround Panel - Black Trim

Standard Surround Trim Only - Brass

Standard Surround Trim Only - Black

Standard Surround Trim Only - Nickel

Oversized Surround Panel - Black Trim

Oversized Surround Trim Only - Nickel

Cottage Face - No Trim

Cottage Trim Kit - Painted Black

Cottage Trim Kit - Gold

Cottage Trim Kit - Pewter

Cottage Trim Kit - Antique Copper

Arched Face - Painted Black

Arched Face - Gold

Arched Face - Nickel

Square Face - Painted Black

Square Face - Gold

Square Face - Nickel

Cape Cod Fascia - Brushed Nickel

Cape Cod Fascia - Brushed Gold

Cape Cod Fascia - Onyx

Cape Cod Fascia - Painted

Cape Cod Fascia - Polished Nickel

Cape Cod Doors - Brushed Nickel

Cape Cod Doors - Brushed Gold

Cape Cod Doors - Onyx

Cape Cod Doors - Painted

Cape Cod Doors - Polished Nickel

Unit Panel & Keystone - Painted

Unit Louvre Set - Painted

Part Number

50-092

50-141

50-142

50-143

50-531

EG31-091

50-111

EG31-103

50-123

50-135

50-112

EG31-107

50-695

50-696

50-597

50-598

50-599

EG31-106

EG31-108

EG31-113

EG31-110

EG31-112

50-487

50-1074

50-1075

50-1076

50-1077

50-1078

50-1079

50-1080

50-1081

50-1082

50-1083

50-1377

50-1378

Parts Diagram - Surrounds & Fascia

27

28

Parts List - Cast

23

23

23

23

23

23

23

23

22

22

22

22

22

22

22

22

24

24

24

24

25

24

24

24

24

Reference Number Part Description

Cast surround only - Painted

Cast surround only - Antique White

Cast surround only - Diamond Black

Cast surround only - Inferno Red

Cast surround only - Pearl Grey

Cast surround only - Wedgewood Blue

Cast surround only - Westport Green

Cast surround only - Antique Chestnut

Cast surround top piece.only - Painted

Cast surround top piece.only - Antique White

Cast surround top piece.only - Diamond Black

Cast surround top piece.only - Inferno Red

Cast surround top piece.only - Pearl Grey

Cast surround top piece.only - Wedgewood Blue

Cast surround top piece.only - Westport Green

Cast surround top piece.only - Antique Chestnut

Cast surround left piece.only - Painted

Cast surround left piece.only - Antique White

Cast surround left piece.only - Diamond Black

Cast surround left piece.only - Inferno Red

Cast surround left piece.only - Pearl Grey

Cast surround left piece.only - Wedgewood Blue

Cast surround left piece.only - Westport Green

Cast surround left piece.only - Antique Chestnut

Cast surround right piece.only - Painted

Cast surround right piece.only - Antique White

Cast surround right piece.only - Diamond Black

Cast surround right piece.only - Inferno Red

Cast surround right piece.only - Pearl Grey

Cast surround right piece.only - Wedgewood Blue

Cast surround right piece.only - Westport Green

Cast surround right piece.only - Antique Chestnut

Cast front only (no surround, glass, valve door, or clip-on) - Painted

50-888

50-395

50-396

50-397

50-398

50-399

50-400

50-401

50-889

50-402

50-887

50-388

50-389

50-390

50-391

50-392

50-393

50-394

50-886

50-381

50-382

50-383

50-384

50-385

50-386

50-387

Part Number

30-036

30-035AW

30-035DB

30-035IR

30-035PG

30-035WB

30-035WG

Parts List - Cast

Reference Number

28

28

28

28

28

28

28

27

27

27

28

27

27

27

27

26

26

26

27

26

26

26

26

25

25

25

26

25

25

25

25

29

Part Description Part Number

Cast front only (no surround, glass, valve door, or clip) - Antique White

Cast front only (no surround, glass, valve door, or clip) - Diamond Black

Cast front only (no surround, glass, valve door, or clip) - Inferno Red

Cast front only (no surround, glass, valve door, or clip) - Pearl Grey

50-403

50-404

50-405

50-406

Cast front only (no surround, glass, valve door, or clip) - Wedgewood Blue 50-407

Cast front only (no surround, glass, valve door, or clip) - Westport Green 50-408

Cast front only (no surround, glass, valve door, or clip) - Antique Chestnut 50-890

Cast valve access door - Painted 30-028

Cast valve access door - Antique White

Cast valve access door - Diamond Black

Cast valve access door - Inferno Red

Cast valve access door - Pearl Grey

Cast valve access door - Wedgewood Blue

Cast valve access door - Westport Green

Cast valve access door - Antique Chestnut

Cast iron front complete - Painted

50-451

50-452

50-453

50-454

50-455

50-456

50-891

50-743

Cast iron front complete - Antique White

Cast iron front complete - Diamond Black

Cast iron front complete - Pearl Grey

Cast iron front complete - Inferno Red

Cast iron front complete - Wedgewood Blue

Cast iron front complete - Westport Green

Cast iron front complete - Antique Chestnut

Cast trim piece - Painted

Cast trim piece - Antique White

Cast trim piece - Diamond Black

Cast trim piece - Inferno Red

Cast trim piece - Pearl Grey

Cast trim piece - Wedgewood Blue

Cast trim piece - Westport Green

Cast trim piece - Antique Chestnut

Clip-on assembly only (for cast bay door)

Cast Bay 3 pieces Glass set with tape

50-744

50-745

50-746

50-747

50-748

50-749

50-811

EG31-399

EG31-399AW

EG31-399DB

EG31-399IR

EG31-399PG

EG31-399WB

EG31-399WG

50-812

50-462

50-496

29

30

Parts Diagram- Cast Bay Front

Warranty

Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location.

Covered under the lifetime warranty are: the surround, the chassis and the heat exchanger. These steel components are covered against manufacturer’s defects for seven (7) years and the labour for the first year. The following exclusions apply: over-firing due to incorrect setup or tampering, or damage caused by incorrect installation, usage or abuse. The unit must be properly installed by a qualified technician or installer, and must meet all local and national gas and building code requirements.

We also cover against manufacturer’s defects, under our Limited Lifetime warranty, the following components:

Log Set, Burners and Glass.

The following exclusions apply:

Plating - Damage caused by scratching, marring, chemicals, fingerprints, abrasive cleaners or discoloration with age. Items with Antique Copper that have had a green discoloration of the finish. If discoloration occurs, please follow the cleaning instructions as outlined in the “Maintaining Face and Surround Finishes” section.

Porcelain Finishes - Damage caused by chipping, scratching, marring, chemicals, fingerprints, abrasive cleaners, discoloration with age

Glass - use of harsh or abrasive cleaners, striking the glass or surface contaminates.

Logset - Damage caused by incorrect handling or misuse.

Burners - damage caused by improper or continuous operation under incorrect conditions.

Sherwood Industries Ltd. offers a two-year warranty on all the electrical components and gas components, against manufacturing defects. Paint is also covered against flaking. This offer includes parts and labour for one year, and parts only thereafter.

Your dealer shall make all claims under this warranty in writing.

WHEN FILING A WARRANTY CLAIM, PLEASE COMPLETE THE FOLLOWING

INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM:

TO THE DEALER:

Name, address and telephone number of purchaser and date of purchase, date of installation, name of installer and dealer, nature of complaint, defects or malfunction, description and part number of any parts replaced.

TO THE DISTRIBUTOR:

Sign and verify that work and information are correct.

This warranty covers defects in materials and workmanship only if the product has been installed according to the manual’s instructions. If the product is damaged or broken as a result of misuse or mishandling, the warranty does not apply. The warranty does not cover removal and reinstallation costs.

Sherwood Industries Ltd. reserves the right to repair or replace the defective product. The shipping costs are to be paid by the consumer. All warranties by the manufacturer are set forth and no claim shall be made against the manufacturer on any oral warranty or representation.

Sherwood Industries Ltd. and its’ employees or representatives will not assume any damages, either directly or indirectly, caused by improper usage, operation installation, servicing or maintenance of this appliance.

Sherwood Industries Ltd. reserves the right to make changes without notice. Please complete and mail the warranty registration card and have the installer fill in the installation data sheet in the back of the manual for warranty and future reference.

31

32

Installation Data Sheet

The following information must be recorded by the installer for warranty purposes and future reference.

NAME OF OWNER: NAME OF DEALER:

_________________________________________

ADDRESS:

_________________________________________

_________________________________________

_________________________________________

PHONE:___________________________________

_________________________________________

ADDRESS:

_________________________________________

_________________________________________

_________________________________________

PHONE:___________________________________

MODEL:___________________________________

SERIAL NUMBER:___________________________

DATE OF PURCHASE: _____________ (dd/mm/yyyy)

DATE OF INSTALLATION:___________ (dd/mm/yyyy)

� NATURAL GAS (NAT) � PROPANE(LPG)

INLET GAS PRESSURE:_________in wc

MAIN BURNER ORIFICE:__________# DMS

PILOT ORIFICE #_________OR________in diam.

INSTALLER’S SIGNATURE:

_________________________________________

NAME OF INSTALLER:

_________________________________________

ADDRESS:

_________________________________________

_________________________________________

_________________________________________

PHONE:___________________________________

MANUFACTURED BY:

SHERWOOD INDUSTRIES LTD.

6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.envirofire.biz

March 20, 2006

C-11074