HP LH4r - NetServer - 256 MB RAM Specifications

Add to my manuals
153 Pages

advertisement

HP LH4r - NetServer - 256 MB RAM Specifications | Manualzz

October 2000

Configuration and Options Guide

EMEA

xSeries

Netfinity

Rack products

Fibre Channel

Storage Enclosures

Clustering

Cables

Options

xSeries 200

xSeries 220

xSeries 230 /

Netfinity 5100

xSeries 240 /

Netfinity 5600

Netfinity 1000

Value Model

Netfinity 3000

Netfinity 3500

M20

Netfinity7100

Netfinity 7600

Netfinity 8500R

Netfinity 6000R

xSeries 340 /

Netfinity 4500R

Netfinity 4000R

xSeries 330

IBM FAStT EXP200

Storage Enclosure

IBM Rack Enclosure

IBM FAStT EXP500

Storage Enclosure

IBM NetBAY3

IBM EXP200

Storage Enclosure

xSeries 150 xSeries 130 xSeries 135

IBM EXP300

Storage Enclosure

Keep Us Informed

The IBM Configuration and Options Guide Survey:

Please give us the benefit of your experience

1. Please rate the value of the IBM Configuration and Options Guide overall.

Very useful ❒

Useful ❒

Not useful ❒

2. Please rate the usefulness of these sections in the IBM Configuration and

Options Guide:

Product Positioning

Selection Guidance

Business Model Summary

Product Family Pages

Sample Configurations

Fibre Array Section

Tape Drives Section

UPS Runtimes Section

Cabling Chart

Very

Useful

Useful

Not

Useful

3. How would you rate the quality of information contained in the IBM Configuration and Options Guide?

❒ Too much

❒ About right

❒ Not enough

4. Does the format allow you to assemble a preliminary Server configuration?

❒ Quickly

❒ Able to get it done

❒ With some difficulty

5. Are you aware of the OrderBUILDER and Spreadsheet configurators that are available on PartnerInfo and the Web at URL: http://www.pc.ibm.com/europe/configurators

❒ Yes

❒ No

6. Other Comments

7. Are you a...? (Check one)

❒ PC Dealer

❒ PC Distributor

❒ PC VAR

❒ IBM Employee

❒ IBM Sales Rep.

❒ IBM Customer

❒ Large Account Customer

❒ Other ___________________________________

8. Please fill in your current address and any changes if required.

Current: Name: _______________________________________________

Company: ____________________________________________

Address: _____________________________________________

City: _______________ ___________Postcode:_____________

Country: ____________ Telephone: _______________________

9. Do you know anyone else that should get the IBM Configuration and

Options Guide?

Name: _______________________________________________

Company: ____________________________________________

Address: _____________________________________________

City: _______________ ______________Postcode__________

Country: __________________ Telephone:__________________

You can fax us at +44 (0) 1256 343964

Or mail it to us at:

IBM xSeries / Netfinity Configurator Team

Mailpoint AL10N, Alencon House

Alencon Link

Basingstoke

RG21 7EJ

UK

This page left intentionally blank

Table of Contents

Positioning of Configurator Aids............................................................................................... .................5

Server Product Positioning .........................................................................................................................6

IBM xSeries and Netfinity Selection Guide ...................................................................................... .........8

IBM xSeries and Netfinity Selection Guide ...................................................................................... .........9

Appliance Server and Business Model Summary.....................................................................................10

IBM xSeries 200 ....................................................................................................................................12

IBM xSeries 220 ...............................................................................................................................20

IBM xSeries 230 and Netfinity 5100 ........................................................................................................26

IBM xSeries 240 and Netfinity 5600 .................................................................................................34

IBM xSeries 330 .......................................................................................................................................42

IBM xSeries 340 and Netfinity 4500R .....................................................................................................48

IBM Netfinity 1000 Value Model Configurator.......................................................................................56

IBM Netfinity 3000 Configurator.............................................................................................................60

IBM Netfinity 3500 M20 Configurator ....................................................................................................66

IBM Netfinity 4000R Configurator ..........................................................................................................72

IBM Netfinity 6000R Configurator ..........................................................................................................76

IBM Netfinity 7100 Configurator.............................................................................................................84

IBM Netfinity 7600 Configurator.............................................................................................................92

IBM Netfinity 8500R Configurator ........................................................................................................100

IBM Netfinity EXP200 Configurator .....................................................................................................110

IBM EXP300 Configurator.....................................................................................................................114

IBM FAStT200 (HA) Configurator ........................................................................................................118

IBM FAStT EXP500 Configurator.........................................................................................................120

Fibre Array Solutions..............................................................................................................................122

IBM Netfinity NetBAY3/NetBAY3E Stackable Enclosure ...................................................................136

IBM Netfinity Rack Cabinet and Options ..............................................................................................138

Appendix A: Tape Drive Attributes........................................................................................................142

Appendix B: Tape Library Attributes ....................................................................................................144

Appendix C: UPS Runtime Estimate (minutes) ....................................................................................146

Appendix D: Cables - Storage Units - Controllers .............................................................................148

Appendix E: IBM Serial I/O ..................................................................................................................150

Appendix F: IBM ServicePacs for Hardware Maintenance ...................................................................151

Important Notes ......................................................................................................................................152

Positioning of Configurator Aids

There are several sources of configuration assistance available which complement one another by providing aid at different levels and with different deliverables.

Any combination of the configurators should be used depending on the situation. Always verify your hardware configurations with

Network Operating System compatibility by accessing the Proven compatibility pages on the World Wide Web at URL http:// www.pc.ibm.com/us/compat

OrderBUILDER Configurator: - a 32-bit Windows application containing local part numbers and prices, enabling the user to configure systems

for all PSG brands. Configurations can be added to a formatted Quote and then either printed directly from OrderBUILDER or exported to another application. OrderBUILDER provides coverage for 29 country versions and weekly update files are distribuuted via the Web and Lotus Notes. See

Distribution and Contact information below.

Spreadsheet Configurator:-

a quick, easy to use tool that incorporates local part numbers and prices in 19 country versions. Euro pricing is also included and the tool enables the user to quickly perform most System and Rack configurations with onscreen guidance provided. It is available in either Microsoft Excel or Lotus 1-2-3 formats and updated versions are distributed monthly via the Web and Lotus Notes.

Rack Configurator:- a graphical Windows application that can be used to configure solutions for the 42U and NetBAY22 Rack Units. It assists the

user to decide optimum placement of items taking into account space, power and weight factors. It provides cabling recommendations and supplies detailed specification sheets, parts lists and floor plans. The Rack Configurator is distributed in one European version and is updated inline with new product announcements.

Configuration and Options Guide (this document!):- produced in Adobe Acrobat (.PDF) format that can be printed and used as hardcopy or

viewed onscreen using Acrobat Reader. This configurator contains the complete range of currently marketed xSeries and Netfinity products and gives, for example, information on which options are required to achieve total amounts of memory or storage, while indicating prerequisite items such as cables. This is a powerful, complete, yet easy to use tool that is produced in one European version. Updated versions are available monthly without pricing.

Tape Sizer - Total Cost of Ownership Tool

:-

this spreadsheet is intended to help evaluate the three-year total cost of ownership estimation for different tape formats, based on the following factors - drive performance, media usage, cartridge changing costs, cleaning fre quency, cleaning cartridge usage. It is produced in Microsoft Excel format only, but can be loaded into Lotus 1-2-3, although formatting and use of navigation links will be affected. The pricing used for the comparison between different solutions is Estimated Selling Price (ESP).

The information contained in this document has not been submitted to any formal IBM test. The following paragraph does not appl y to the United

Kingdom or any country where any such provisions are inconsistent with local law.

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER

EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE. SOME STATES DO NOT ALLOW DISCLAIMER OF EXPRESS OR IMPLIED WARRANTIES IN CERTAIN TRANSACTIONS.

THEREFORE, THIS STATEMENT MAY NOT APPLY TO YOU. THERE IS NO GUARANTEE THAT IBM WILL MARKET ANY PARTICULAR PRODUCT

IN YOUR COUNTRY.

The use of this information or the implementation of any of these techniques is a customer responsibility and depends on the customer’s ability to evaluate and integrate them into the customer’s operational environment. While each item may have been reviewed by IBM for accuracy in a specific situation, there is no guarantee that the same or similar results will be obtained elsewhere. Customers attempting to adapt these techniques to their own environments do so at their own risk. The sample configurations contained within this document are for illustratio n only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.

Configurator Distribution

All Users

:

Internet: http://www.pc.ibm.com/europe/configurators OrderBUILDER Updates, latest versions of Spreadsheet Configurator, Configuration and Options Guide, Rack Configurator, Tape Sizer.

Business Partners:

Lotus Notes: PC PartnerInfo:- Marketing Essentials Database - OrderBUILDER Updates, Spreadsheet Configurator, Configuration and Options Guide, Rack Configurator, Tape Sizer; Business Essentials Database - OrderBUILDER Updates, Spreadsheet Configurator.

IBM Internal: IBM EMEA xSeries / Netfinity Intranet site: w3.ibm.com/psg/emea/xseries - OrderBUILDER Application and Updates, Spread-

sheet Configurator, Configuration and Options Guide, Rack Configurator, Tape Sizer.

The OrderBUILDER application is available on CD - to receive your copy, send an e-mail to the address below with your name, company and full address details (not PO Box numbers)

For further information contact:- e-mail: [email protected]

Notes Mail: EMEA PSG-Configuration-Support/UK/IBM@IBMGB

5

Updated

17/10/00

Server Product Positioning

IBM xSeries and Netfinity Servers

Increasing:

Performance

Capacity

Availability

File and

Print

To access information on the World Wide Web, use address: http://www.pc.ibm.com

Number of Clients

6

Updated

17/10/00

7

Updated

17/10/00

When in a competitive situation, this table suggests the appropriate IBM xSeries or Netfinity server to bid against other vendors’ equipment. However, as an IBM business partner, you may determine that customer specific requirements may make an alternative IBM solution a better choice

8-way

4-way

2-way

Uni

Value

IBM: xSeries 220,

Netfinity 3500 M20

Compaq: ProLiant ML350

Dell: PowerEdge 1300

HP: NetServer E60

IBM: xSeries 200,

Netfinity 1000

Compaq: ML330

Dell: No Offering

HP: No Offering

Price Performance

IBM: Netfinity 7100

Compaq: ProLiant 5500,

ML570

Dell: PowerEdge 6400

HP: NetServer LH4

IBM: xSeries 230,

Netfinity 5100

Compaq: ProLiant ML370

Dell: PowerEdge 2400

HP: NetServer LC2000

IBM: Netfinity 3000

Compaq: ProLiant 400

Dell: No Offering

HP: No Offering

Mission Critical

IBM: Netfinity 8500R

Compaq: ProLiant 8000

Dell: No Offering

HP: NetServer LH 6000,

LT6000R

IBM: Netfinity 7600

Compaq: No Offering

Dell: No Offering

HP: NetServer LXr 8000

IBM: xSeries 240,

Netfinity 5600

Compaq: ProLiant ML530

Dell: PowerEdge 4400

HP: NetServer LH 3000

Rack Optimized

IBM: Netfinity 8500R

Compaq:ProLiant 8500

Dell: PowerEdge 8450

HP: NetServer LXr 8000

IBM: Netfinity 6000R

Compaq: ProLiant 6400, DL580

Dell: PowerEdge 6450

HP: NetServer LH4r

IBM: xSeries 330, 340,

Netfinity 4000R, 4500R

Compaq: ProLiant DL380, DL360

Dell: PowerEdge 2450

HP: NetServer LPr

IBM xSeries and Netfinity Selection Guide

.

This chart represents general guidelines for selecting the appropriate server based on the number of users that can be supported in a particular application environment. This chart is for general guidance since each customer environment is unique and is unlikely to be precisely represented by any of the specific applications in the chart, but by using the chart, a reasonable approximation can be derived. External Storage Units are utilized when internal capacities are exceeded. Utilize the chart by following the steps outlined on the following page. These are not published benchmark results. Access http://www.ibm.com/pc/us/techlink/srvperf.html to obtain benchmark data.

Application/Expectation of Maximum # of Users

# of Users

DB Transaction Processing

Select, Update and Delete;

# of processors

Memory (MB)

Does not include image or

Decision Support

# Hard Disk Drives

# RAID Adapters

#Network Connections

# of Users

File and Print applications - cut number of users in half).

# of Processors

Application is stored locally.

(For server stored

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# 100Mbps Ethernet

Connections

# of Users

# of Processors

Lotus Notes

10% Power Users 40% Mail

50% Mail & DB

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

# of Users

Netfinity 1000

Value Model

Uni-Pentium

III 700 MHz/

256KB

50

1

384

3

-

1

100

1

512

3

-

> 2

100

1

384

3

-

> 1

600

Netfinity 3000

Uni-

Pentium III

700 MHz/

256 KB

1125

1

768

12 to 18

> 1 SCSI

1

1000

1

768

4 to 8

> 1 SCSI

> 2

675

1

768

4 to 8

> 1 SCSI

> 1

700 xSeries 200

Uni-

Pentium III

866 MHz/

256 KB

1280

1

768

12 to 18

>1 SCSI

1

1000

1

768

4 to 8

> 1 SCSI

> 2

740

1

1 GB

4 to 8

> 1 SCSI

> 1

1980

Netfinity 3500

M20 Dual

Pentium III

800 MHz/

256 KB

1950

2

1 to 2 GB

36 to 48

>1

1

2000

2

1 to 2 GB

16 to 24

1 to 2

4

1800

2

2 GB

16 to 20

1

>2

850 xSeries 220

Dual

Pentium III

933 MHz/

256 KB

1325

1

768

12 to 18

>1

1

1000

1

768

4 to 8

1

4

735

1

768

4 to 8

1

>2

2200 xSeries 330

Dual

Pentium III

1 GHz/

256 KB

2170

2

1 to 2 GB

36 to 48

>2

1

2100

2

1 to 2 GB

20 to 30

1 to 2

4

2000

2

2GB

20 to 30

1 to 2

>2

2310

Microsoft Exchange

Server

5.5

100% Med Users

30 MB Mailbox

# of Processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

1

256

3

1

384

3 to 4

2

1 GB

9

1

512

3 to 4

2

1 GB

10

2

2 GB

10

# Network Connections

SAP 3-Tier Distributed

Ver 4.0b

Processing

Sales and Distribution

Application

(Minimum of 16-20 Servers)

See Note 1.

# of Users

# of Processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

SAP Central

Ver 4.0b

Processing

Sales and Distribution

Application

(One Server)

See Note 1.

# Users

# Processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

Hot-Swap HDD Bays

Hot-Plug PCI Slots

Hot-Swap Power

High Availability

Features

Hot-Swap Fans

RAID

Clustering Support

Sys. Mgt. Processor

Max # Processors

Max Memory (MB)

Other Distinquishing

Features

Max Int. Storage (GB)

Max Int. Storage (GB) with

Int. Tape drive

Available PCI Slots

19” Rack Models

NetBAY3x Support

-

-

1

768

30.3

-

-

-

-

-

-

-

-

-

-

-

> 1

-

-

-

N/A

-

N/A

-

30.3

3

-

-

-

Opt.

1

768

145.6

-

-

-

-

-

Opt.

> 1 SCSI

> 1

-

-

-

N/A

-

-

-

-

-

N/A

-

109.2

2

-

-

-

-

2

2 GB

145.6

-

-

1

-

-

Opt.

75

1

-

-

-

-

1

>1

-

N/A

1 GB

12

>1

145.6

5

-

-

-

Opt.

1

768

145.6

-

-

1

-

-

Opt.

> 1 SCSI

>1

-

-

-

N/A

-

-

139

2

1 GB

12 to 24

>1

109.2

5

-

-

-

Opt.

1

768

145.6

-

-

1

-

-

Opt.

> 1 SCSI

>1

-

-

-

N/A

80

1

-

-

1 GB

12

>1

109.2

5

-

-

-

-

2

2 GB

72.8

-

-

1

-

-

Opt.

-

-

160

2

-

-

1

>2

-

N/A

1 GB

12 to 24

>1

N/A

2

-

-

1. This information for SAP is a guide only. Refer to the IBM SAP R/3 Advanced Sizing and Planning Questionnaires at: www.pc.ibm.com/europe/configurators , or to your IBM representative, for more information.

8

Updated

17/10/00

To access information on the World Wide Web, use address: http://www.pc.ibm.com

IBM xSeries and Netfinity Selection Guide

9

Updated

17/10/00

Application/Expectation of

Maximum # of Users

# of Users

DB Transaction Processing

Select, Update and Delete;

Does not include image or

Decision Support

# of processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

#Network Connections

# of Users

File and Print # of Processors

Application is stored locally.

(For server stored

Memory (MB)

# Hard Disk Drives applications - cut number of users in half).

# RAID Adapters

# 100Mbps Ethernet Conn.

# of Users

# of Processors

Lotus Notes

10% Power Users 40% Mail

50% Mail & DB

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

# of Users

Microsoft Echange

Server 5.5

100% Med Users

30 MB Mailbox

# of Processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

SAP 3-Tier Distributed

Ver 4.0b

Processing

Sales and Distribution

Application

(Minimum of 16-20 Servers)

See Note 1.

# of Users

# of Processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

SAP Central

Ver 4.0b

Processing

Sales and Distribution

Application

(One Server)

See Note 1.

High Availability

Features

Other Distinquishing

Features

# Users

# Processors

Memory (MB)

# Hard Disk Drives

# RAID Adapters

# Network Connections

Hot-Swap HDD Bays

Hot-Plug PCI Slots

Hot-Swap Power

Hot-Swap Fans

RAID

Clustering Support

Sys. Mgt. Processor

Max # Processors

Max Memory (MB)

Max Int. Storage (GB)

Max Int. Storage (GB) with

Int. Tape drive

Available PCI Slots

19” Rack Models

NetBAY3x Support

X

X

X

X

X

245

4

>2 GB

24 to 36

>2

1

X

X

4

16GB

364

4 GB

40 to 50

>3

>2

3350

4

>4 GB

48 to 60

>3

1

245

4

>2 GB

24 to 36

>2

1

X

X

4

16GB

364

X

Opt.

X

X

Opt.

>3 GB

30 to 40

>2

>2

3150

4

>4 GB

48 to 60

>3

1

312

4

>2 GB

24 to 36

>2

1

X

X

X

X

Opt.

-

X

4

16 GB

218.4

3 GB

30

2

>2

4300

4

>4 GB

48 to 60

>3

1

180

2

1 to 2 GB

12 to 24

>1

1

X

X

X

X

Opt.

X

X

2

4 GB

218.4

2 GB

12

2

>1

2800

2

1 to 2 GB

24 to 36

>2

1

162

2

1 to 2 GB

12 to 24

>1

1

X

-

Opt.

-

Opt.

X

X

2

4 GB

218.4

2 GB

12

1

>1

2790

2

1 to 2 GB

24 to 36

>2

1

160

2

1 GB

12 to 24

>1

1

X

-

X

X

Opt.

X

X

2

4 GB

218.4

2 GB

9

1

>1

-

N/A

-

-

-

xSeries 340 /

Netfinity 4500R

Dual

Pentium III

1 GHz/

256 KB xSeries 230

Netfinity 5100

Dual

Pentium III

1 GHz/

256 KB xSeries 240

Netfinity 5600

Dual

Pentium III

1 GHz/

256 KB

Netfinity 6000R Netfinity 7100

Quad

Pentium III

Quad

Pentium III

Xeon

700 MHz/

2048 KB

Xeon

700 MHz/

2048 KB

Netfinity 7600

Quad

Pentium III

Xeon

700 MHz/

2048 KB

2720

2

2720

2

3650

2

6420

4

6420

4

6420

4

2 to 3 GB

48 to 64

>2

1

2100

2

1 to 2 GB

20 to 30

1 to 2

4

2110

2 to 3 GB

48 to 64

>2

1

2100

2

1 to 2 GB

20 to 30

1 to 2

4

2110

4 GB

80 to 140

>3

2 to 3

2100

2

1 to 2 GB

20 to 30

1 to 2

4

2110

4 GB

80 to 140

>4

2 to 3

5000

2

2 to 4 GB

50 to 90

4

8

4215

4 GB

80 to 140

>5

2 to 3

5000

2

2 to 4 GB

50 to 90

>4

8

4215

4 GB

80 to 140

>5

2 to 3

5000

2

2 to 4 GB

50 to 90

>4

8

4215

2

2 to 3 GB

20 to 30

1 to 2

>2

2310

2

2 to 3 GB

20 to 30

1 to 2

>2

2310

2

2 to 3 GB

20 to 30

1 to 2

>2

2310

4

3 GB

20 to 30

2 to 3

>3

6400

4

3 GB

20 to 30

2 to 3

>3

6600

4

3 GB

20 to 30

2 to 3

>3

7000

2

109.2

5

X

-

2

218.4

5

X

-

2

218.4

5

X

-

4

N/A

6

X

-

4

364

6

X

X

4

364

5

X

X

Netfinity 8500R

Eight-Way

Pentium III

Xeon

700 MHz/

2048 KB

10,315

8

4 GB

180 to 250

>5 or Fibre

2 to 3

6000

3-4

4 GB

75 to 150

>4 or Fibre

10

6695

8

4 GB

30 to 40

>3

>4

8000

1. This information for SAP is a guide only. Refer to the IBM SAP R/3 Advanced Sizing and Planning Questionnaires at: www.pc.ibm.com/europe/ configurators , or to your IBM representative, for more information.

2. 8500R - with a Rack-to-Tower kit installed.

8

N/A

12

X

X

2

375

8

>4 GB

24 to 36

>2

1

X

X

X

X

Opt.

X

X

8

32 GB

72.8

4 GB

40 to 50

>3

>2

5100

8

>4 GB

48 to 60

>3

1

Procedure for Server Selection Guidance Chart

File and Print numbers are Novell Netware-based with all others based on Microsoft Windows NT. Other Networking Operating System (NOS) results could vary.

Extensive SAP sizings are available from IBM/SAP Competency Centres. Contact your IBM Marketing Representative for additional information .

Step 1: Determine which application (row) most closely represents the customer’s environment.

Step 2: Move from left to right along the row (chosen in Step 1) noting which columns contain numbers that are equal to or greater than the maximum customer’s planned number of users.

Step 3: Move up the columns (chosen in Step 2) to the top row to determine which IBM xSeries or Netfinity Servers should be considered as possible solutions.

Step 4: Evaluate other features such as storage, memory capacity, high availability components, number of available expansion slots, etc., which are unique to each server, in order to determine which is the most appropriate to recommend.

For your reference, configuration information corresponding to the number of users is also provided.

Appliance Server and Business Model Summary

APPLIANCE SERVERS

xSeries 130 xSeries 135 xSeries 150 xSeries 150

-

-

-

-

K41YXxx

K41XXxx

K833Yxx

K83XYxx

BUSINESS MODELS

xSeries 330 xSeries 330 xSeries 330 xSeries 330 xSeries 340 xSeries 230 xSeries 240

-

-

-

-

-

-

-

K412Gxx

K432Gxx

K442Gxx

K452Gxx

K66SGxx

K862Gxx

K481Gxx

800

3

800

3

800

3

800

3

800

3

866

3

933

3

1GHz

3

1GHz

3

1GHz

3

1GHz

3

1/2 256

1/2 256

1/2 256

2/2

2

256

256MB

R

/1GB

1,4

256MB

R

/1GB

1,4

256MB

R

/2GB

4

1GB

R

/2GB

4

Rack(1U) 1/1 2 x 10/100

OB

Rack(1U) 1/1 2 x 10/100

OB

Tower 2/3 2 x 10/100

17

Rack(5U) 2/3 4 x 10/100

18

1 x 37L7204

1 x 37L7204

37L6091 3 x 37L7206

19

37L6889 6 x 37L7206

19

4/1 2/1

14

4/1 2/0

14

NOTE: 15

NOTE: 16

10/5

10/2

5/3 NOTE: 20

5/1 NOTE: 21

1/2 256 512MB

R

/4GB

4,10

1/2 256 512MB

R

/4GB

4,10

1/2 256 512MB

R

/4GB

4,10

1/2 256 512MB

R

/4GB

4,10

1/2

1/2

1/2

256

256

256

256MB

R

/4GB

4,8

256MB

R

/4GB

4,8

512MB

R

/4GB

4,6

Rack(1U) 1/1 2 x 10/100

OB

Rack(1U) 1/1 2 x 10/100

OB

Rack(1U) 1/1 2 x 10/100

OB

Rack(1U) 1/1 2 x 10/100

OB

Rack(3U)

Tower

Tower

1/2

1/3

2/3

10/100

OB

10/100

OB

10/100

OB

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

2 x 37L7205

2 x 37L7205

2 x 37L7205

2 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

4/0

4/0

4/0

4/0

8

9

/3

10/5

10/5

2/1

2/1

2/1

2/1

K411Yxx

K431Yxx

K441Yxx

K451Yxx

5/4 K66RYxx

5/4 K861Yxx

5/4 K481Yxx

5100

5600

5600

5600

6000R

6000R

7100

7100

4500R

4500R

4500R

4500R

5100

5100

5100

7100

7100

7100

7100

7100

7100

-

-

-

-

-

-

-

-

-

-

-

854G9xx

454G9xx

464G9xx

474G9xx

-

-

23GG9xx

24GG9xx

24/10/00 65TG9xx

24/10/00 66TG9xx

614G9xx

634G9xx

644G9xx

654G9xx

824G9xx

834G9xx

844G9xx

-

-

67TG9xx

68TG9xx

24/10/00 65GG9xx

24/10/00 66GG9xx

-

-

67GG9xx

68GG9xx

800

3

866

3

700

5

700

5

550

5

550

5

700

5

700

5

700

5

700

5

550

5

550

5

933

3

800

3

866

3

933

3

733

3

800

3

866

3

933

3

733

3

1/2

1/2

1/2

1/2

256

256

256

256

256MB

R

/4GB

4,8

256MB

R

/4GB

4,8

256MB

R

/4GB

4,8

256MB

R

/4GB

4,8

256MB

R

/4GB

4,8

1/2 256

1/2 256 256MB

R

/4GB

4,8

256MB

R

/4GB

4,8

1/2 256

2/4

2

2/4

2

2/4

2

2/4

2

2/4

2

2/4

2

2/4

2

2/4

2

2/4

2

1/2 256

1/2 256

256MB

R

/4GB

4,8

512MB

R

/4GB

4,6

1/2 256 512MB

R

/4GB

4,6

1/2 256

2/4

2

1024

512MB

512MB

R

R/

/4GB

4,6

16GB

11

2048 512MB

R/

16GB

11

512 512MB

7

/16GB

1024

1024

2048

512

1024

1024

2048

512MB

7

/16GB

512MB

7

/16GB

512MB

7

/16GB

512MB

7

/16GB

512MB

7

/16GB

512MB

7

/16GB

512MB

7

/16GB

Rack(3U) 1/2

Rack(3U) 1/2

Rack(3U) 1/2

Rack(3U) 1/2

Tower 1/3

Tower

Tower

1/3

1/3

Tower

Tower

Tower

Tower

Rack(4U) 1/3

Rack(4U) 1/3

Tower

Tower

2/4

2/4

1/3

2/3

2/3

2/3

Tower

Tower

2/4

2/4

Rack(8U) 2/4

Rack(8U) 2/4

Rack(8U) 2/4

Rack(8U) 2/4

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

10/100

OB

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

37L6091

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

8

9

/3

8

9

/3

8

9

/3

8

9

/3

10/5

10/5

10/5

10/5

10/5

10/5

5/4

5/4

5/4

5/4

5/4

5/4

5/4

5/4

5/4

5/4

61RYMxx

63RYTxx

64RYTxx

65RYTxx

821YExx

831YExx

841YExx

851YExx

451YExx

461YExx

3 x 37L7205 10/5 5/4 471YExx

3 x 37L7205 8

12

/3 6/5 21RYMxx

3 x 37L7205 8

12

/3 6/5 22RYMxx

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

14/9

14/9

14/9

14/9

6/5

6/5

6/5

6/5

611YExx

621YExx

631YMxx

641YMxx

3 x 37L7205

3 x 37L7205

3 x 37L7205

3 x 37L7205

14/9

14/9

14/9

14/9

6/5

6/5

61RYExx

62RYExx

6/5 63RYMxx

6/5 64RYMxx

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

10

Updated

17/10/00

* Business Models are standard models shipped with additional options already installed. They provide popular starting configurations that give price&packaging advantages for easy installation. Appliance Servers are pre-configured with a pre-loaded, tuned, software stack to allow simple ‘out-of-the-box’ installation and instant enhancement of Web server capabilities.

1. These pre-configured, pre-loaded Appliance Servers support limited expansion capability.

2.One additional processor (of the same type and speed as the standard one) is supplied already installed with this Business Model.

3. Intel Pentium III processor with advanced transfer (full speed) L2 cache and 133MHz Front-side bus (FSB).

4. High-speed 133MHz SDRAM.

5. Intel Pentium III Xeon processor with advanced transfer (full speed) L2 cache.

6. One additional 256MB memory option P/N 33L3060 is supplied already installed with this Business Model.

7. The standard memory is replaced in these models with four 128MB memory options P/N 33L3113 - already installed.

8. The standard memory is replaced in this model with one 256MB RDIMM P/N 33L3125 - already installed

9. Assumes installation of optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit (P/N 33L5050) which converts the two available removable media bays into three slimline (SL) hot-swap bays.

10. One additional 256MB memory option P/N 33L3144 is supplied already installed with this Business Model.

11. Advanced Chipkill ECC memory - corrects two, three or four-bit errors.

12. Assumes installation of optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit (P/N 33L5050) which enables hot-swap bays 4 to 6.

13. Not available from IBM after this date: Business Partner inventory may be available.

14. The xSeries 130 Appliance Server supports the addition of 1 x P/N 3430301 Gigabit Ethernet Adapter only. The xSeries 135 Appliance Server does not support the addition of any adapters. Additional options support is limited for both of these servers.

15. The xSeries 130 Web Hosting Appliance Server is pre-loaded with a tuned Windows Powered operating system and is ready to use ‘out-of-the-box’. Pre-loaded software includes: Windows Powered OS, Microsoft Internet Information Services 5.0, Netfinity Web Server Accelerator V2.0, Advanced appliance configuration utility, Netfinity

Director 2.12 UM Server Extensions (agent version).

16. The xSeries 135 Web Hosting Appliance Server is pre-loaded with a tuned Turbo Linux operating system and is ready to use ‘out-of-the-box’. Pre-loaded software includes:

Turbo Linux OS, IBM HTTP Server, Appliance System Management, Advanced appliance configuration utility. The xSeries 135 Appliance Server pre-loaded software stack does not support the onboard Advanced System Management Processor

17. The xSeries 150 Network Attached Storage Appliance Server P/N K833Yxx (Tower model) includes one 10/100 onboard Ethernet controller and one additional 10/100

Ethernet adapter. Additional options support is limited for this server.

18. The xSeries 150 Network Attached Storage Appliance Server P/N K83XYxx (Rack model) includes one 10/100 onboard Ethernet controller and three additional 10/100

Ethernet adapters. Additional options support is limited for this server.

19. Only the Rack model P/N K83XYxx supports external storage via the attachment of an EXP300 enclosure.

20. The xSeries 150 Network Attached Storage Appliance Server P/N K833Yxx is pre-loaded with a tuned Windows Powered operating system and is ready to use ‘out-of-thebox’. Pre-loaded software includes: Windows Powered OS, Netfinity Director 2.12 UM Server Extensions (agent version), ServeRAID Manager RAID configuration and monitoring utilities, Advanced appliance configuration utility, Columbia Data Products Open Transaction Manager. This model is designed and configured to be a Workgroup

Model. It includes a ServeRAID 4L adapter and 3 x 36.4GB Ultra160 hot-swap disks.

21. The xSeries 150 Network Attached Storage Appliance Server P/N K83XYxx is pre-loaded with a tuned Windows Powered operating system and is ready to use ‘out-of-thebox’. Pre-loaded software includes: Windows Powered OS, Netfinity Director 2.12 UM Server Extensions (agent version), ServeRAID Manager RAID configuration and monitoring utilities, Advanced appliance configuration utility, Columbia Data Products Open Transaction Manager. This model is designed and configured to be a Departmental

Model. It includes a ServeRAID 4H adapter and 6 x 36.4GB Ultra160 hot-swap disks

11

Updated

17/10/00

IBM xSeries 200

xSeries 200 At-A-Glance Chart

K811Xxx

K812Xxx

K813Xxx

K841Xxx

K842Xxx

K851Xxx

3

-

-

-

-

-

-

667

1

667

1

667

1

800

4

800

4

866

4

866

4

1/1

1/1

1/1

1/1

1/1

1/1

128

128

128

256

256

256

64MB/1.5GB

64MB/1.5GB

128MB/1.5GB

64MB/1.5GB

128MB/1.5GB

64MB/1.5GB

Tower

Tower

Tower

Tower

Tower

Tower

1/1

1/1

1/1

1/1

1/1

1/1

-

-

-

-

-

-

10/100

10/100

10/100

10/100

10/100

10/100

IDE

IDE

4/2

4/1

15/90GB

2

15/90GB

2

U160 4/2 9.1/145.6GB

2

48X-20X 7/4

48X-20X 7/3

48X-20X 7/4

3

IDE 4/2 15/90GB

2

U160 4/2 9.1/145.6GB

2

IDE 4/2 15/90GB

2

U160 4/2 9.1/145.6GB

2

48X-20X 7/4

48X-20X 7/4

48X-20X 7/4

48X-20X 7/4 K852Xxx

-

1/1 256 128MB/1.5GB

Tower 1/1 10/100

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Intel Celeron processor.

2. Maximum capacity assumes replacement of standard hard disk drives and tape drive (if installed), with the largest supported IBM hard disk drive.

3. This model is configured with an IBM 10/20GB TR5 Internal IDE Tape Drive P/N 20L0549 as standard.

4. Intel Pentium III processor with advanced transfer (full speed) L2 cache and 133 MHz front-side bus (FSB).

xSeries 200 Processor Upgrades

Part Number Processor Upgrades 256 KB Advanced Transfer Cache Processor Speed

Upgrade

1

21P9539

10K3818

800 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor

866 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor

All K81xXxx

All K81xXxx...K84xXxx

1.Requires removal of the standard processor. A maximum of one processor may be installed. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/ pc/support and enter machine type “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

5/4

5/5

5/4

5/5

5/5

5/4

5/5

DIMM Socket

DIMM Socket

DIMM Socket

Part Number

33L3079

33L3081

33L3083

33L3085

Memory Description

64MB 133MHz ECC SDRAM DIMM Memory

128MB 133MHz ECC SDRAM DIMM Memory

256MB 133MHz ECC SDRAM DIMM Memory

512MB 133MHz ECC SDRAM Unbuffered

DIMM Memory xSeries 200 Memory Configurator

Total System Memory

1

Standard

Model with 64MB

Standard

Model with 128MB

DIMMs

64 MB

P/N 33L3079

128 MB

P/N 33L3081

256 MB

P/N 33L3083

512 MB

P/N 33L3085

128 MB

192 MB

320 MB

384 MB

2

576 MB

768 MB

2

1088 MB

192 MB

256 MB

384 MB

-

640 MB

768 MB

2

1152 MB

1

2 or

-

1

2 or

3

1

2 or

3

1

2

1536 MB

(max)

2

1536 MB

2

3

This table does not represent all possible memory configurations. Memory modules may vary in price per MB.

Selection of smaller DIMMs may provide a more cost-effective alternative to using larger DIMMs. Select the desired total memory from the appropriate column (Standard Model 64MB or 128MB), then select a quantity in that row from one of the DIMM columns.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. Requires removal of standard DIMMs.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

12

Updated

17/10/00

13

Updated

17/10/00 xSeries 200 Internal Hard Disk Drive and External Storage Configurator

Bay

1

2

3

4

5...7

Form

Factor

133 mm

(5.25”)

133 mm

(5.25”)

89 mm

(3.5”)

89mm

(3.5”)

89mm

(3.5”)

Total

Internal

Storage

1

7200RPM Ultra160 SCSI Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8204)

18.2 GB

(P/N 00N8205)

36.4 GB

(P/N 00N8206)

9.1GB

18.2GB

27.3GB

36.4GB

45.5GB

54.6GB

1

2 or

3

-

1 and

Standard on Base SCSI Models (7200 rpm)

-

1

-

2 or

2

-

-

-

1

-

81.9GB

91GB

100.1GB

145.6GB

(max)

2

-

1 and

-

-

-

-

1 and

-

2

2

2

4

2

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.

2. Maximum capacity assumes replacement of standard hard disk drives and tape drive (if installed) with the largest supported IBM hard disk drive.

CD-ROM

Bay 2

Diskette

Bay 4

Bay 5

Bay 6

Bay 7

10,000 RPM Ultra160 SCSI Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8207)

18.2 GB

(P/N 00N8208)

36.4 GB

(P/N 00N8209)

1

2 or

Standard on Base SCSI Models (7200 rpm)

-

1

3

-

1 and

-

2 or

2

-

1 and

-

-

-

1 and

-

-

1

-

-

-

2

2

2

4

2

Total

Internal

Storage

1

7200RPM IDE Hard Disk Drives (HDDs)

2

15 GB

(P/N 19K4460)

20.4 GB

(P/N 19K4461)

30 GB

(P/N 00N8203 )

15GB

30GB

45GB

55.8GB

75GB

90GB (max)

4

2

3

1

-

-

-

or

Standard on EIDE Base Models

-

-

2

3

-

-

This table does not represent all possible hard drive configurations.

-

1

-

2

3

3

4

1. Select a total storage row and then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +0.2 GB unless otherwise noted.

2. The xSeries 200 EIDE controllers support a maximum of four IDE devices per machine including CD-ROM drives, hard disks and IDE tape drives.

3. Not a supported configuration on model P/N K812Xxx which includes an IBM 10/20 GB TR5 Internal IDE Tape

Drive P/N 20L0549 as standard.

4. Maximum capacity assumes replacement of standard hard disk drives and tape drive (if installed) with the largest supported IBM hard disk drive.

Height

HH

HH

SL

SL

SL

Front

Access yes yes yes yes yes

Usage

IDE CD-

ROM open

1, 2

Diskette open open

Part

Number

Description

IDE Hard Disk Drives (HDD)

1, 2

19K4460 15GB 7200 rpm ATA/100 (EIDE) HDD

19K4461 20.4GB 7200 rpm ATA/100 (EIDE) HDD

00N8203 30GB 7200 rpm ATA/100 (EIDE) HDD

Ultra160 Hard Disk Drives (HDD)

2

RPM Height

7200

7200

7200

SL

SL

SL

Bays

Supported

4...7

4...7

4...7

Max.

Qty

3

3

3

3

3

3

1. Supports removable media devices only. Hard drives are not supported.

2. 10/20GB TR5 Internal IDE Tape Drive P/N 20L0549 is standard in model P/N K812Xxx.

00N8204 9.1GB 7200 rpm Ultra160 SCSI HDD

00N8205 18.2GB 7200 rpm Ultra160 SCSI HDD

00N8206 36.4GB 7200 rpm Ultra160 SCSI HDD

00N8207 9.1GB 10,000 rpm Ultra160 SCSI HDD

00N8208 18.2GB 10,000 rpm Ultra160 SCSI HDD

00N8209 36.4GB 10,000 rpm Ultra160 SCSI HDD

External Storage Expansion Units

4

00N6xxx

7

Netfinity EXP200 Storage Expansion Unit

5

37L5857

37L0xxx

19K11xx

8

9

Netfinity EXP200 Rack-to-Tower

Conversion Kit

Netfinity EXP200 350 W Redundant Power

Supply

EXP300 Storage Expansion Unit

6

09N7296 EXP300 Rack-to-Tower Conversion Kit

7200

7200

7200

10,000

10,000

10,000

SL

SL

SL

SL

SL

SL

Form Factor

Rack (3U)

4...7

4...7

4...7

4...7

4...7

4...7

-

-

Rack (3U)

-

4

4

4

4

4

4

1.The xSeries 200 EIDE controllers support a maximum of four IDE devices per machine including CD-ROM drives, hard disks and IDE tape drives.

2. Mixing of IDE and SCSI hard disk drives is not supported.

3. Limited to 2 drives in model -12X due to installed tape drive option.

4. Not supported by the external SCSI port included in SCSI models. Select an optional SCSI controller then refer to Appendix D:

Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

5. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply and standard country power cord. Optional hot-swap Netfinity EXP200 350W Redundant Power Supply (P/N 37L0xxx) includes an additional standard country power cord. To convert an EXP200 to match the system’s tower form factor, Netfinity EXP200 Rack-to-Tower

Conversion Kit P/N 37L5857 is required.

6. EXP300 includes a single 2M Ultra2 SCSI cable and dual hot-swap 500 W redundant power supplies, each with its own standard country power cord. To convert an EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit P/N

09N7296 is required.

7. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South Africa/

English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication Country Kits are included throughout.

8. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/

English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

9.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/English,

58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication Country Kits are included throughout.

xSeries 200 Internal SCSI Cabling

EIDE Models

In xSeries 200 models using the EIDE interface for storage device attachment, a two-drop cable is used to attach the standard 15 GB EIDE HDD to one of the EIDE connectors. A second EIDE controller provides the interface for the IDE CD-ROM drive. A two-drop cable connects the IDE controller to the IDE CD-ROM. Up to two additional EIDE or IDE devices can be installed (one off of each controller).

SCSI Models xSeries 200 models with a SCSI adapter are cabled internally with a five-drop, 16-bit wide LVD SCSI cable with a built-in multi-mode active terminator at one end of the cable. The other end of the cable is attached to the internal 68-pin connector of the standard Ultra160 SCSI adapter. SCSI devices can be connected to any of the five cable connectors. If 8-bit

(narrow) devices are to be installed, a 68- to 50-pin converter (32G3925) is required for each narrow device.

Other Configuration Alternatives

In the case where a RAID controller is used to support internal drives in a xSeries 200, the standard cable is moved from the onboard controller to the RAID adapter. To connect a tape drive to the onboard or other supported SCSI controller, use the 16-bit multi-mode terminated, two-drop, SCSI cable included with optional Media Bay Tray and LVD Cable Kit

(P/N 10K2340).

External SCSI support can be obtained by installing an optional SCSI adapter or RAID controller and using appropriate external SCSI cabling.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

14

Updated

17/10/00

15

Updated

17/10/00

Part

Number

Description

Storage Controllers

2

37L6091 ServeRAID-4L Ultra160 SCSI Controller

3

37L6080 ServeRAID-4M Ultra160 SCSI Controller

4

19K4646 PCI Wide Ultra160 SCSI Adapter

7

02K3454 PCI Fast/Wide Ultra SCSI Adapter

Networking

5

Ethernet

09N9901 10/100 EtherLink Server Adapter by 3Com

34L0301 Netfinity Gigabit Ethernet SX Adapter

19K4401 Netfinity Gigabit Ethernet Adapter

34L4601 Netfinity 10/100 Ethernet Security Adapter

Token Ring

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

34L5001 16/4 Token-Ring PCI Management Adapter

Communications

6

37L14xx Serial I/O SST 8, 16 and 128 Port Adapters

8 xSeries 200 I/O Options

Adapter

Length

Full

Full

Half

Half

Half

Half

Half

Half

Half

Half

PCI

Support

32/64-bit

32/64-bit

32-bit

32-bit

32-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32-bit

Slots

Supported

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1

-

External Connector Access

Half 32-bit 1...5

1. The xSeries 200 has five full-length, 33 MHz PCI expansion slots. The number of available slots is model specific.

2. Some models of the xSeries 200 include a single channel Ultra160 SCSI Adapter with a five drop multi-mode terminated LVD SCSI Cable. All other models include dual-channel EIDE controllers and require an optional SCSI adapter for SCSI functionality. See At-A-Glance for model attributes

3. ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection.

External connector is 0.8-mm VHDCI.

4. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two external 0.8-mm VHDCI Ultra160 connectors.

5. xSeries 200 includes an integrated full-duplex, 10.100 Mbps Ethernet controller.

6. xSeries 200 includes two USB ports, two high-speed serial/asynchronous ports, (NS16550A software compatible) and one high-speed parallel port supporting devices using SSP/EPP/ECP protocols adhering to the IEEE 1284 Standard.

7. PCI Wide Ultra160 SCSI Adapter P/N 19K4646 provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm

VHDCI connector. Only one of the two connectors may be utilised.

8. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416) may be installed.

xSeries 200 Power, Monitors, Accessories

Part Number

94G7448

Description

Power

1,10

Rack Power Cable Type C12 (3.7m)

10

Free Standing Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 700 SUP072Y

SUP102Y

SUP142Y

14RIxxx

9

30RIxxx

9

37L6862

T3347xx

8

31H2Nxx

8

T32N3xx

8

T274Axx

8

11AG1xx

8

APC Smart-UPS 1000

APC Smart-UPS 1400

Rack Mount Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 1400RMB

3,10

APC Smart-UPS 3000RMB

3,10

APC Smart-UPS 5000RMB

4,10

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

6

6

6

G78 Color Monitor 17” (406.4mm, 16.0” Viewable Image Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable Image Size), stealth black

7

1. The xSeries 200 includes a 330 W voltage sensing power supply and a single standard country power cord.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. The xSeries 200 contains a S-3 Savage-4 LT video adapter with 8Mb of video memory plugged into the standard AGP slot.

6. Installation within a rack requires optional Monitor Compartment (P/N94G7444).

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II (P/N 37L6888) and Netfinity Rack Keyboard Tray (P/

N 28L4707). A space saver keyboard may coexist within the same 28L4707 keyboard tray.

8. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland,

UK=UK, EU=Europe.

9. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa,

SWS=Switzerland, UKM=United Kingdom, EUR=Europe.

10. The xSeries 200 ships with a standard country power cord. If conversion to Rack format is being carried out, Rack Power Cable P/N 94G7448

(type C12), must be ordered to allow connection to a high voltage UPS or PDU.

Part Number Description

Conversion Kits

09N4300 4Ux20D Tower-to-Rack Kit

6

Rack and NetBAY

1,6

930842P

930842X

9306900

9306910

36L9703

9306200

36L9702

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (Perforated Doors)

Netfinity Rack Extension Kit

Netfinity NetBAY22

NetBAY22 Rack Extension Kit

37L6888

94G7448

Netfinity Flat Panel Monitor Rack Mount Kit II

Rack Power Cable Type C12 (3.7m)

6

Keyboard and Mouse

2

Space Saver II Keyboard

3, 4

28L36xx

5

1 Rack installation of an xSeries 200 requires 4Ux20D Tower-to-Rack Kit (P/N 09N4300) and one of the racks listed here. See IBM Netfinity Rack

Cabinet and Options section for IBM rack supported devices.

2. The xSeries 200 includes both a mouse and non-space saver keyboard.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

5. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English,

19K3831=Switzerland, 19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

6. The xSeries 200 ships with a standard country power cord. If conversion to Rack format and connection to a high voltage UPS or PDU is being carried out, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

16

Updated

17/10/00

17

Updated

17/10/00 xSeries 200 Tape Options

Part

Number Supported Interface

(bit)

Factor Included Converter

Included.

Ext. Tape

Enclosures

1

20L0549

09N4041

09N4042

00N7991

10/20GB TR5 Internal IDE Tape Drive

2

12/24GB DDS/3 4-mm Internal SCSI

Tape Drive

3,4,5

10/20GB NS Internal SCSI Tape Drive

3,4,5

20/40 GB DDS/4 4-mm Internal Tape

Drive

4,5

2, 4

2

2, 4

2

-

8

8

16 Ultra2

LVD

101.6mm

(3.5” SL or

133mm

(5.25”) HH

89 mm (3.5”)

HH or 133 mm (5.25”)

HH

89 mm (3.5”)

SL or 133 mm (5.25”)

HH

89 mm (3.5”)

HH or 133 mm (5.25”)

HH

-

Y

Y

Y

-

Y

Y

N/A

-

10L7440,

03K8756

10L7440,

03K8756

10L7440,

03K8756

6

10L7440

03K8756

10L7113

External Tape Enclosures

External Half High SCSI Storage Enclosure

7

NetMEDIA Storage Expansion Unit EL

8

NetMEDIA Systems Management Adapter

9

Associated Options

-

-

-

8/16

16

16 LVD

Desktop

Rack

-

N

Y

N

N

N

N

-

-

03K8756

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

Media Bay Tray and LVD Cable Kit

4,6,10

16 LVD/SE External Y N 10L7440

10K2340 16 LVD Internal Y N -

Note: SCSI models include an Ultra160 SCSI controller with a five-drop multi-mode terminated LVD SCSI cable. Single-Ended devices attached to this cable will limit the entire SCSI bus to single- ended performance. SCSI tape drives and external tape enclosures are supported by PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode LVD SCSI cable and an external 0.8-mm VHDCI connector.

1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to Appendix D:

Cables - Storage Units - Controllers.

2. SCSI models include a two-drop EIDE cable for attachment to the CD-ROM and an optional IDE tape drive. EIDE Model P/N K812Xxx includes 10/20GB TR5 Internal IDE Tape Drive P/N 20L0549 as standard.

3.This single-ended device will limit the SCSI bus to which it is attached to Ultra SCSI speeds. To provide a dedicated tape SCSI bus, install PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode LVD SCSI cable.

4. For RAID configurations (in SCSI models) where the standard SCSI cable is attached to a RAID adapter, the two-drop multi-mode terminated LVD SCSI cable included with Media Bay Tray and

LVD Cable Kit P/N 10K2340 is required, to allow attachment of a SCSI Tape Drive to the standard Ultra160 SCSI Adapter.

5. EIDE models require optional PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode LVD SCSI cable, to allow attachment of a SCSI Tape Drive.

6. LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL P/N 03K8756 requires replacement of the standard single-ended internal cables with one or more (depending on configuration) cables from Media Bay Tray and LVD Cable Kit P/N 10K2340 which contains a single two-drop mult-mode terminated LVD cable. If the standard cables are used for attachment to LVD devices, single-ended SCSI rules and bus speeds apply.

7. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin

External Multimode LVD/SE SCSI Terminator P/N 00N7956.

8. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

9. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in an Expansion Unit P/N 03K8756 to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

10. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

xSeries 200 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

Part Number

K812Xxx

33L3081

19K4461

31H2Nxx

SUP072Y

1. For a total of 192 MB of system memory.

2. For a total of 35.4 GB of internal storage.

Description x200 Celeron 667/128, 64MB, EIDE, 15GB, Tape, 48X

128 MB 133Mhz ECC SDRAM DIMM Memory

1

20.4 GB 7200 rpm ATA/100 (EIDE) HDD

2

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

Quantity

1

1

1

1

1

An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (firewall). In the case of an

Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.

With this is mind, the the xSeries 200 was selected to provide an affordable price point for the growing Internet server market with two-way Pentium III processing, 192 MB of system memory (expandable to 1.5 GB), and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods are used you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

File and Print Server

Part Number Description

K852Xxx

33L3081

00N8204

00N8205

00N7991

31H2Nxx

SUP072Y x200 Pentium III 866/256, 128MB, Ultra160, 1 x 9.1GB, 48X

128 MB 133 MHz ECC SDRAM DIMM Memory

1

9.1 GB Ultra160 SCSI HDD

2

18.2 GB Ultra160 SCSI HDD

2

20/40GB DDS/4 4-mm Internal Tape Drive

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

1. For a total of 256 MB of system memory.

2. For a total of 54.6 GB of internal storage.

Quantity

1

1

2

1

1

1

1

A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing environment, but doesn’t require the high-end performance and fault-tolerance properties of larger servers.

The sample configuration above consists of an xSeries 200 with 256 MB of memory and 54.6 GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.

This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected during power surges and outages.

Application Server

Part Number Description

K852Xxx

33L3083

37L6091

00N8204

10K2340

09N4042

31H2Nxx

SUP072Y x200 Pentium III 866/256, 128MB, Ultra160, 1 x 9.1GB, 48X

256 MB 133 MHz ECC SDRAM DIMM Memory

ServeRAID-4L Ultra160 SCSI Controller

9.1 GB Ultra160 SCSI HDD

2

Media Bay Tray and LVD Cable Kit

3

10/20 GB NS Internal SCSI Tape Drive

1

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

1. For a total of 384 MB of system memory.

2. For a total of 27.3 GB of internal storage.

3. Cable for dedicated attachment of tape to standard controller.

Quantity

1

1

3

1

1

2

1

1

An application server differs from a file and print server in that it has a higher workload, in providing application serving requirements for users. With this in mind, the xSeries 200 was selected to provide an affordable price point for an application server, with Pentium III processing, 384 MB of system memory (expandable to 1.5 GB), and availability features such as RAID-protected internal storage and power protection with an APC Smart-UPS.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

18

Updated

17/10/00

19

Updated

17/10/00

IBM xSeries 220

xSeries 220 At-A-Glance Chart

K521Xxx

K522Xxx

K52AXxx

K531Xxx

K532Xxx

K53AXxx

K541Xxx

K542Xxx

-

-

-

-

-

-

-

-

800

800

800

866

866

866

933

933

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

256

256

256

256

256

256

256

256

128MB(R)/4GB

128MB(R)/4GB

128MB(R)/4GB

128MB(R)/4GB

128MB(R)/4GB

128MB(R)/4GB

128MB(R)/4GB

128MB(R)/4GB

Tower

Tower

Tower

Tower

Tower

Tower

Tower

Tower

1/1

1/1

1/1

1/1

K54AXxx 933 1/2 256 128MB(R)/4GB Tower 1/1

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Intel Pentium III processor with advanced transfer (full speed) L2 cache.

2. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

1/1

1/1

1/1

1/1

-

-

-

H

H

H

-

-

-

-

-

-

-

-

-

-

-

-

10/100

10/100

10/100

10/100

10/100

10/100

10/100

10/100

10/100

U160 4/2

U160 4/2

U160 4/2

U160 4/2

U160 4/2

U160 4/2

U160 4/2

U160 4/2

U160 4/2

0/145.6GB

48X-20X 7/5

18.2/145.6GB

48X-20X 7/4

0/145.6GB

0/145.6GB

48X-20X

48X-20X

7/5

7/5

18.2/145.6GB

48X-20X 7/4

0/145.6GB

48X-20X 7/5

0/145.6GB

48X-20X 7/5

18.2/145.6GB

48X-20X 7/4

0/145.6GB

48X-20X 7/5

5/5

5/5

5/5

5/5

5/5

5/5

5/5

5/5

5/5 xSeries 220 Processor Upgrades

Part Number Processor Upgrades with Advanced Transfer Cache SMP Support

1

Processor Speed

Upgrade

2

21P9539

10K3818

800 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor

Netfinity 866 MHz with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Upgrade

Processor

All K52xXxx

All K53xXxx

-

All K52xXxx

10K3819

Netfinity 933 MHz with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Upgrade

Processor

All K54xXxx All K52xXxx...K53xXxx

1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.

2.Requires removal of the standard processor. A maximum of one processor may be installed. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine type “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

DIMM Socket

DIMM Socket

DIMM Socket

DIMM Socket

Part Number

33L3142

33L3144

33L3146

33L3152

Memory Description

128MB 133MHz SDRAM ECC RDIMM

Memory

256MB 133MHz SDRAM ECC RDIMM

Memory

512MB 133MHz SDRAM ECC RDIMM

Memory

1 GB 133MHz SDRAM ECC RDIMM xSeries 220 Memory Configurator

Total

System

Memory

1

128 MB

(1 x 128)

256MB

384 MB

512 MB

640 MB

896 MB

1024 MB

1152 MB

1664 MB

128 MB

(33L3142)

1

2 or

3

-

-

-

-

-

Quantity of RDIMMs Added

256 MB

(33L3144)

-

1

-

2 or

3

4

2

512 MB

(33L3146)

-

1

-

-

-

-

2 or

3

1 GB

(33L3152)

-

-

-

-

-

-

1

-

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

20

Updated

17/10/00

21

Updated

17/10/00

2048 MB

2176 MB

3200 MB

-

-

-

4

-

-

2

-

2

3

4096 MB

(max)

4

2

This table does not represent all possible memory configurations. Memory modules may vary in price per MB. Selection of smaller DIMMs may provide a more cost-effective alternative to using larger DIMMs. Select the desired total memory from the lefthand column (standard memory is

128MB), then select a quantity in that row from one of the DIMM columns.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. Requires removal of standard memory.

xSeries 220 Internal Hard Disk Drive and External Storage Configurator

Total

Internal

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8204 or

37L7201)

2

18.2 GB

(P/N 00N8205 or

37L7202)

2

36.4 GB

(P/N 00N8206 or

37L7203)

2

10,000 RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8207 or

37L7204)

2

18.2 GB

(P/N 00N8208 or

37L7205)

2

36.4 GB

(P/N 00N8209 or

37L7206)

2

0 GB

9.1GB

18.2GB

27.3GB

36.4GB

1

Standard on Base Models

-

3

4

3

2 1 -

-

2 1

1

2

3

4

3

Standard on Base Models

-

1

-

2

-

-

-

1

45.5GB

54.6GB

72.8GB

-

-

-

-

3 -

4

3

2

-

-

-

-

3

4

3

-

-

2

91GB

109.2GB

-

-

-

-

-

3

4

3

-

-

-

-

-

3

4

3

145.6GB (max) -

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.

2. Both hot-swap and non-hot-swap HDDs are listed. Select the appropriate part number for the model of xSeries 220 being configured.

3. A maximum of three hot-swap drives may be installed in hot-swap models. This configuration requires installation of a non-hot-swap HDD in Bay 4.

Part

Number

Description

Non-Hot-Swap Ultra160 Hard Disk

Drives (HDD)

1

00N8204 9.1GB 7200 rpm Ultra160 SCSI HDD

00N8205 18.2GB 7200 rpm Ultra160 SCSI HDD

00N8206 36.4GB 7200 rpm Ultra160 SCSI HDD

00N8207 9.1GB 10,000 rpm Ultra160 SCSI HDD

00N8208 18.2GB 10,000 rpm Ultra160 SCSI HDD

00N8209 36.4GB 10,000 rpm Ultra160 SCSI HDD

Hot-Swap Ultra160 Hard Disk Drives

(HDD)

2

37L7201 9.1GB Ultra160 SCSI Hot-Swap SL HDD

37L7202 18.2GB Ultra160 SCSI Hot-Swap SL HDD

37L7203 36.4GB Ultra160 SCSI Hot-Swap SL HDD

37L7204

9.1GB 10K-4 Ultra160 SCSI Hot-Swap SL

HDD

37L7205

18.2GB 10K-4 Ultra160 SCSI Hot-Swap SL

HDD

37L7206

36.4GB 10K-4 Ultra160 SCSI Hot-Swap SL

HDD

External Storage Expansion Units

3

00N6xxx

6

Netfinity EXP200 Storage Expansion Unit

4

37L5857

37L0xxx

7

19K11xx

8

Netfinity EXP200 Rack-to-Tower

Conversion Kit

Netfinity EXP200 350 W Redundant Power

Supply

EXP300 Storage Expansion Unit

5

09N7296 EXP300 Rack-to-Tower Conversion Kit

RPM Height

7200

7200

7200

10,000

10,000

10,000

7200

7200

7200

10,000

10,000

10,000

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

Form Factor

Rack (3U)

-

-

Rack (3U)

-

Hot-Swap Models

Bays

Supported

Maximum

Quantity

4

4

4

4

4

4

5...7

5...7

5...7

5...7

5...7

5...7

1

1

1

1

1

1

3

3

3

3

3

3

Non-Hot-Swap Models

Bays

Supported

Maximum

Quantity

-

-

-

-

-

-

4...7

4...7

4...7

4...7

4...7

4...7

4

4

4

4

4

4

-

-

-

-

-

-

1.Non-hot-swap HDDs are supported in bays 4...7 of non-hot swap models and in bay 4 of hot-swap models.

2.Hot-swap HDDs are supported in bays 5...7 of hot-swap models. Bay 4 supports non-hot-swap HDDs only.

3. Not supported by the onboard SCSI controller. Select an optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

4. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply and standard country power cord. Optional hot-swap Netfinity EXP200 350W

Redundant Power Supply (P/N 37L0xxx

7

) includes an additional standard country power cord. To convert an EXP200 to match the system’s tower form factor, Netfinity EXP200 Rackto-Tower Conversion Kit (P/N 37L5857) is required.

5. EXP300 includes a single 2M Ultra2 SCSI cable and dual hot-swap 500 W redundant power supplies, each with its own standard country power cord. To convert an EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit (P/N 09N7296) is required.

6. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish, 902=European/French, 903=European/German, 904=Danish/English,

905=Israel/English, 906=Italian/Italian, 907=South Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication Country Kits are included throughout.

7. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/English, 080=South Africa/English, 081=Swiss/English,

082=UK/English. Line Cords/Publication Kits are included throughout.

8.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/English, 58=Italian/English, 59=South Africa/English, 60=Swiss/

English, 63=UK/English:- Line Cords/ Publication Country Kits are included throughout.

Bay Form

Factor

Height Front

Access

Usage

1

2

3

4

133 mm

(5.25”)

133 mm

(5.25”)

89 mm

(3.5”)

89mm

(3.5”)

HH

HH

SL

SL yes yes yes yes

IDE CD-

ROM open

1

Diskette open

5...7

89mm

(3.5”)

SL

2 yes open

1. This bay does not support hard drive options. It can be used for removable media devices such as tape drives.

2. These bays will be configured as hot-swap bays on model P/Ns

K52AXxx, K53AXxx, K54AXxx.

xSeries 220 Internal SCSI Cabling

Non-Hot-Swap Models xSeries 220 non-hot-swap models are cabled internally with a five-drop, 16-bit wide LVD SCSI cable with a built-in multi-mode active terminator on one end of the cable. The other end of the cable is attached to the internal 68-pin connector of the integrated Ultra160 SCSI controller. SCSI devices can be connected to any of the five cable connectors. If 8-bit

(narrow) devices are to be installed, a 68- to 50-pin converter (32G3925) is required for each narrow device.

Hot-Swap Models xSeries 220 hot-swap models are cabled internally with a two-drop, 16-bit wide LVD SCSI cable. One end is connected to the internal 68-pin connector of the integrated Ultra160

SCSI controller. The first drop is designed to support a SCSI device in the 3.5-inch non-hot-swap bay, while the second drop is connected to the hot-swap SCSI backplane.The SCSI backplane provides termination for the SCSI bus.

Other Configuration Alternatives

In the case where a RAID controller is used to support internal drives in a xSeries 220, the standard cable is moved from the onboard controller to the RAID adapter. To connect a tape drive to the onboard or other supported SCSI controller, the two-drop cable from Media Bay Tray and LVD Cable Kit (P/N 10K2340) must be used.

External SCSI support can be obtained by installing an optional SCSI adapter or RAID controller and using appropriate external SCSI cabling.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

22

Updated

17/10/00

23

Updated

17/10/00

Part

Number

Description

Storage Controllers

2

37L6091 ServeRAID-4L Ultra160 SCSI Controller

3

37L6080 ServeRAID-4M Ultra160 SCSI Controller

4

19K4646 PCI Wide Ultra160 SCSI Adapter

5

02K3454 PCI Fast/Wide Ultra SCSI Adapter

Networking

6

Ethernet

09N9901 10/100 EtherLink Server Adapter by 3Com

34L0301 Netfinity Gigabit Ethernet SX Adapter

19K4401 Netfinity Gigabit Ethernet Adapter

34L4601 Netfinity 10/100 Ethernet Security Adapter

Token Ring

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

34L5001 16/4 Token-Ring PCI Management Adapter

Communications

8

37L14xx Serial I/O SST 8, 16 and 128 Port Adapters

9 xSeries 220 I/O Options

Adapter

Length

Full

Full

Half

Half

Half

Half

Half

Half

Half

Half

PCI

Support

32/64-bit

32/64-bit

32-bit

32-bit

32-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32-bit

Slots

Supported

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

7

1...5

7

1

-

External Connector Access

Half 32-bit 1...5

1. The xSeries 220 has five full-length, 33 MHz PCI expansion slots, three 64-bit and two 32-bit.

2. xSeries 220 has an integrated Ultra160 SCSI Controller with a single internal channel and includes a five drop, multi-mode terminated LVD SCSI cable.

3. ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection.

External connector is 0.8-mm VHDCI.

4. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two external 0.8-mm VHDCI Ultra160 connectors.

5. PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm

VHDCI connector. Only one of the two connectors may be utilized.

6. The xSeries 220 includes an integrated full-duplex, 10/100 Mbps Ethernet controller.

7. Wake on LAN function supported when installed in slot 1 only.

8. xSeries 220 includes two USB ports, two high-speed serial/asynchronous ports, (NS16550A software compatible) and one high-speed parallel port supporting devices using SSP/EPP/ECP protocols adhering to the IEEE 1284 Standard.

9. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416) may be installed.

xSeries 220 Power, Monitors, Accessories

Part Number

94G7448

Description

Power

1,10

Rack Power Cable Type C12 (3.7m)

10

Free Standing Uninterruptible Power Supply (UPS)

2

SUP072Y

SUP102Y

APC Smart-UPS 700

APC Smart-UPS 1000

SUP142Y

14RIxxx

9

30RIxxx

9

37L6862

T3347xx

8

31H2Nxx

8

T32N3xx

8

T274Axx

8

11AG1xx

8

APC Smart-UPS 1400

Rack Mount Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 1400RMB

3,10

APC Smart-UPS 3000RMB

3,10

APC Smart-UPS 5000RMB,

4,10

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

6

6

6

G78 Color Monitor 17” (406.4mm, 16.0” Viewable Image Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable Image Size), stealth black

7

1. The xSeries 220 includes a 330 W voltage sensing power supply and a single standard country power cord..

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. The xSeries 220 includes an integrated SVGA controller(S3 Savage4 Chipset) with 8Mb of video memory

6. Installation within a rack requires optional Monitor Compartment (P/N94G7444).

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II (P/N 37L6888) and Netfinity Rack Keyboard Tray (P/

N 28L4707). A space saver keyboard may coexist within the same 28L4707 keyboard tray.

8. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland,

UK=UK, EU=Europe.

9. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa,

SWS=Switzerland, UKM=United Kingdom, EUR=Europe.

10. The xSeries 220 ships with a standard country power cord. If conversion to Rack format is being carried out, Rack Power Cable P/N 94G7448

(type C12), must be ordered to allow connection to a high voltage UPS or PDU.

Part Number Description

Conversion Kits

09N4300 4Ux20D Tower-to-Rack Kit

6

Rack and NetBAY

1,6

930842P

930842X

9306900

9306910

36L9703

9306200

36L9702

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (Perforated Doors)

Netfinity Rack Extension Kit

Netfinity NetBAY22

NetBAY22 Rack Extension Kit

37L6888

94G7448

Netfinity Flat Panel Monitor Rack Mount Kit II

Rack Power Cable Type C12 (3.7m)

6

Keyboard and Mouse

2

Space Saver II Keyboard

3, 4

28L36xx

5

1 Rack installation of an xSeries 220 requires 4Ux20D Tower-to-Rack Kit (P/N 09N4300) and one of the racks listed here. See IBM Netfinity Rack

Cabinet and Options section for IBM rack supported devices.

2. The xSeries 220 includes both a mouse and non-space saver keyboard.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

5. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English,

19K3831=Switzerland, 19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

6. The xSeries 220 ships with a standard country power cord. If conversion to Rack format and connection to a high voltage UPS or PDU is being carried out, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

xSeries 220 Tape Options

Part

Number

Description Bays

Supported

SCSI

Interface

(bit)

Form

Factor

Terminatio n Included

68/50-pin

Converter

Incl.

Ext. Tape

Enclosures

1

09N4041

09N4042

00N7991

12/24GB DDS/3 4-mm Internal SCSI

Tape Drive

2, 3

10/20GB NS Internal SCSI Tape Drive

2, 3

20/40 GB DDS/4 4-mm Internal Tape Drive

3

2

2, 4

2

8

8

16 Ultra2

LVD

89 mm (3.5”) HH or

133 mm (5.25”) HH

89 mm (3.5”) SL or

133 mm (5.25”) HH

89 mm (3.5”) HH or

133 mm (5.25”) HH

Y

Y

Y

Y

Y

N/A

10L7440,

03K8756

10L7440,

03K8756

10L7440,

03K8756

4

10L7440

03K8756

10L7113

External Tape Enclosures

External Half High SCSI Storage Enclosure

5

NetMEDIA Storage Expansion Unit EL

6

NetMEDIA Systems Management Adapter

7

Associated Options

-

-

-

8/16

16

16 LVD

Desktop

Rack

-

N

Y

N

N

N

N

-

-

03K8756

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

Media Bay Tray and LVD Cable Kit

3,4,8

16 LVD/SE External Y N 10L7440

10K2340 16 LVD Internal Y N -

Note: All models include an Ultra160 SCSI controller with a five-drop multi-mode terminated LVD SCSI cable. Single-Ended devices attached to this cable will limit the entire SCSI bus to single- ended performance. All tape drives and external tape enclosures are supported by PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) which includes a five-drop multi-mode terminated LVD SCSI cable and an external 0.8-mm VHDCI connector.

1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to Appendix D:

Cables - Storage Units - Controllers.

2.This single-ended device will limit the SCSI bus to which it is attached to Ultra SCSI speeds. To provide a dedicated tape SCSI bus, install PCI Wide ultra160 SCSI Adapter (P/N 19K4646) which includes a five-drop multi-mode LVD SCSI cable.

3. For RAID configurations where the standard SCSI cable is attached to a RAID adapter, the two-drop multi-mode terminated LVD SCSI cable included with Media Bay Tray and LVD Cable Kit P/N

10K2340 is required, to allow attachment of a SCSI Tape Drive to the standard Ultra160 SCSI controller.

4. LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL (P/N 03K8756) requires replacement of the standard single-ended internal cables with one or more (depending on configuration) cables from Media Bay Tray and LVD Cable Kit (P/N 10K2340) which contains a single two-drop mult-mode terminated cable. If the standard cables are used for attachment to LVD devices, single-ended SCSI rules and bus speeds apply.

5. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin

External Multimode LVD/SE SCSI Terminator (P/N 00N7956).

6. NetMEDIA Storage Expansion Unit EL (P/N 03K8756) is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

7. NetMEDIA Systems Management Adapter (P/N 10L7113) may be installed in an Expansion Unit P/N 03K8756 to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

8. Media Bay Tray and LVD Cable Kit (P/N 10K2340) includes an internal two-drop multi-mode terminated LVD SCSI cable.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

24

Updated

17/10/00

25

Updated

17/10/00 xSeries 220 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

Part Number

K53AXxx

33L3142

37L7202

00N7991

31H2Nxx

SUP072Y

1. For a total of 256 MB of system memory.

2. For a total of 36.4 GB of internal storage.

Description x220 866 Mhz/256KB, 128MB ECC, OPEN-HS, 48X, PCI

128 MB 133Mhz SDRAM ECC RDIMM

1

18.2 GB Ultra160 SCSI Hot-Swap SL HDD

2

20/40 GB DDS/4 4-mm Internal Tape Drive

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

Quantity

1

1

1

1

2

1

An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (firewall). In the case of an

Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.

With this is mind, the xSeries 200 was selected to provide an affordable price point for the growing Internet server market with two-way Pentium III processing,

256 MB of system memory (expandable to 4 GB), and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods are used you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

File and Print Server

Part Number Description

K52AXxx

33L3142

37L7202

00N7991

31H2Nxx

SUP072Y x220 800 Mhz/256KB, 128MB ECC, OPEN-HS, 48X, PCI

128 MB 133Mhz SDRAM ECC RDIMM

1

18.2 GB Ultra160 SCSI Hot-Swap SL HDD

2

20/40 GB DDS/4 4-mm Internal Tape Drive

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

1. For a total of 256 MB of system memory.

2. For a total of 54.6 GB of internal storage.

Quantity

1

1

3

1

1

1

A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing environment, but doesn’t require the high-end performance and fault-tolerance properties of larger servers.

The sample configuration above consists of an xSeries 220 with 256 MB of memory and 54.6 GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.

This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected during power surges and outages.

Application Server

Part Number Description

K542Xxx

10K3819

33L3144

37L6091

00N8205

10K2340 x220 933 MHz/256KB, 128MB ECC, 18.2GB, 48X, PCI

Netfinity 933 MHz with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium

III Upgrade Processor

256 MB 133 MHz SDRAM ECC RDIMM

1

ServeRAID-4L Ultra160 SCSI Controller

18.2GB 7200 rpm Ultra160 SCSI HDD

Media Bay Tray and LVD Cable Kit

3

2

00N7991

31H2Nxx

20/40 GB DDS/4 4-mm Internal Tape Drive NS Internal SCSI Tape Drive

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

SUP072Y APC Smart-UPS 700

1. For a total of 384 MB of system memory.

2. For a total of 54.6 GB of internal storage.

3. Contains a cable for dedicated attachment of tape to standard controller.

Quantity

1

1

1

1

1

2

1

1

1

An application server differs from a file and print server in that it has a higher workload, in providing application serving requirements for users. With this in mind, the xSeries 220 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 384 MB of system memory (expandable to 4 GB), and availability features such as RAID protected internal storage and power protection with an APC Smart-UPS.

IBM xSeries 230 and Netfinity 5100

xSeries 230 / Netfinity 5100 At-A-Glance Chart

xSeries 230

K861Yxx

K86RYxx

1

-

-

1 GHz 1/2 256

1 GHz 1/2 256

128MB

(R)/4GB

128MB

(R)/4GB

Tower 1/3

P-Optional,

H

Rack(5U) 1/3

P-Optional,

H

O-Power

O-Power

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

0/218.4

GB

0/218.4

GB

40X-17X 10/8 5/5

40X-17X 10/8 5/5

Netfinity 5100

811YExx

81RYExx

1

821YExx

82RYExx

1

831YExx

83RYExx

1

841YExx

84RYExx

1

851YExx

85RYExx

1

24/10/00 667 1/2 256

24/10/00 667 1/2 256

-

-

-

-

-

-

-

-

733 1/2 256

733 1/2 256

800 1/2 256

800 1/2 256

866 1/2 256

866 1/2 256

933 1/2 256

933 1/2 256

128MB

(R)/4GB

128MB

(R)/4GB

Tower

128MB

(R)/4GB

Rack (5U) 1/3

P-Optional,

H

Tower

1/3

P-Optional,

H

1/3

P-Optional,

H

128MB

(R)/4GB

Rack (5U) 1/3

P-Optional,

H

128MB

(R)/4GB

Tower 1/3

P-Optional,

H

128MB

(R)/4GB

Rack (5U) 1/3

P-Optional,

H

128MB

(R)/4GB

Tower 1/3

P-Optional,

H

128MB

(R)/4GB

Rack (5U) 1/3

P-Optional,

H

128MB

(R)/4GB

Tower 1/3

P-Optional,

H

128MB

(R)/4GB

Rack (5U) 1/3

P-Optional,

H

O-Power

O-Power

O-Power

O-Power

O-Power

O-Power

O-Power

O-Power

O-Power

O-Power

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

Y 10/100 D,U160 4/2

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

0/218.4

GB

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

40X-17X 10/8 5/5

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See Power, Monitors, Accessories section for supported IBM racks.

2. High-speed, 133 MHz SDRAM.

3. Up to two additional 250 W Hot-Swap Redundant Power Supplies P/N 33L37xx and a single Hot-Swap Power Supply Expansion Kit P/N 37L6881 are required for power supply redundancy.

See Power, Monitors, Accessories section for additional information.

4. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

5. Intel Pentium III processor with advanced transfer (full-speed) L2 cache and 133 MHz Front-Side Bus.

6. Not available from IBM after this date. Business Partner inventory may be available.

xSeries 230 / Netfinity 5100 Processor Upgrades

Part Number Processor Upgrades with 256 KB Cache

(Full Speed)

SMP Support

1

Processor Speed Upgrade

2

00N7949

00N7943

10K2338

19K4630

19K4631

19K4640

3

Netfinity 667 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 733 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 800 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 866 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 933 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

1 GHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache

Pentium III Processor

1xY

2xY

3xY

4xY

5xY

3

6xY

-

1xY

All 1...2xY

All 1...3xY

-

5xY

1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

3. Netfinity 933 MHz Upgrade Processor P/N 19K4631 is only supported on models P/N 85xYExx due to thermal restrictions.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

26

Updated

17/10/00

27

Updated

17/10/00

R DIMM Socket 4

R DIMM Socket 3

R DIMM Socket 2 xSeries 230 / Netfinity 5100 Memory Configurator

Total Memory

1

128 MB

(1 x 128)

Models

256 MB

384 MB

128 MB

(33L3123)

1

2 or

R DIMM Socket 1

Std. (R)DIMM

The recommended order of installation:

Slot 1-2-3-4

Part Number Memory Description

1

33L3123 128 MB 133 MHz SDRAM ECC RDIMM II

33L3125

33L3127

256 MB 133 MHz SDRAM ECC RDIMM II

512 MB 133 MHz SDRAM ECC RDIMM II

1 GB 133 MHz SDRAM ECC RDIMM II 33L3129

1. The recommended order of installation is in sequence from Socket 1 to Socket 4.

Memory size is not a factor.

512 MB 3

Quantity of RDIMMs Added

256 MB

(33L3125)

-

1

-

512 MB

(33L3127)

-

-

-

1 GB

(33L3129)

-

-

-

640 MB

896 MB

1024 MB

1152 MB

1664 MB

-

-

-

-

-

2 or

3

4

2

-

-

1

-

-

2 or

3

4

2

-

-

-

1

-

2048 MB -

2176MB

3200 MB

4096 MB (max)

-

-

-

-

-

-

-

-

-

2

3

4

2

This table does not represent all possible memory configurations. Memory modules may vary in price per MB.

Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. Requires removal of standard memory.

xSeries 230 / Netfinity 5100 Internal Hard Disk Drive and External Storage Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs) 10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

18.2 GB

(P/N 37L7202)

36.4 GB

(P/N 37L7203)

9.1 GB

(P/N 37L7204)

18.2 GB

(P/N 37L7205)

36.4 GB

(P/N 37L7206)

0 GB

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

54.6 GB

4

5

6

1

2

3

Standard on Base Models

-

1

-

2

-

3

1

-

-

-

-

-

4

5

6

1

2

3

Standard on Base Models

-

1

-

2

-

3

72.8 GB

91 GB

109.2 GB

-

-

-

4

5

6

2

-

3

-

-

-

4

5

6

2

-

3

145.6 GB

182 GB

-

-

-

-

4

5

-

-

-

-

4

5

218.4 GB

(max.)

6 6

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

1

-

-

-

-

-

Bay

A

B

-

-

Form

Factor

133 mm

(5.25”)

133 mm

(5.25”)

133 mm

(5.25”)

89 mm

(3.5”)

Height

HH

1

HH

1

SL

SL

Front

Access

Yes

Yes

Yes

Yes

Usage

Open

Open

IDE CD-

ROM

Diskette

Part

Number

Description RPM Height

Hot-Swap Ultra160 Hard Disk Drives (HDD)

Bays

Supported

37L7201

37L7202

37L7203

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap SL

HDD

36.4 GB Ultra160 SCSI Hot-Swap SL

HDD

7200

7200

7200

SL

SL

SL

C...H

C...H

C...H

Max.

Qty.

6

6

6

C...H

HS

Tower Model View

Removable Media (RM)

A

B

CD-ROM

Hot-Swap

(HS)

C

D

E

F

G

H

SL

2

1. Two half-high (HH) bays can be combined to support a single full-high (FH) device. Installation of devices in Bays A or B may require Netfinity Hot-Swap

Power Supply Expansion Kit (P/N 37L6881) and at least one Netfinity 250 W Hot-

Swap Redundant Power Supply (P/N 33L37xx). Installation of HDDs in Bays A and B also requires Media Bay Tray and LVD Cable Kit (P/N 10K2340).

2. Two slim-line (SL) bays (C/D, E/F, G/H) can be combined to support a single half-high (HH) device.

For clarity purposes, bay labels in these diagrams are for reference by the accompanying tables and are not the actual labels. Refer to the documentation shipped with the system for further details on actual labels.

Rack Model View

Hot-Swap (HS)

G F E D

Removable Media (RM)

C

Yes

A

B

CD-ROM

Diskette

Open 37L7204

37L7205

37L7206

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

10,000

10,000

10,000

SL

SL

SL

C...H

C...H

C...H

19K0655

19K0656

9.1 GB 15K-rpm Ultra160 SCSI Hot-

Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

15,000

15,000

SL

SL

C...H

C...H

Non-Hot-Swap Internal Hard Disk Drives (HDDs)

20L0553 9.1 GB Wide Ultra2 SCSI HDD

1

20L0554 18.2 GB Wide Ultra2 SCSI HDD

1

7200

7200

SL

SL

A, B

1

A, B

1

Associated Options

10K2340 Media Bay Tray and LVD Cable Kit

2

-

33L37xx

9

250 W Hot-Swap Redundant Power

Supply

-

-

-

A/B

-

6

6

6

6

6

2

2

1

-

37L6881

Hot-Swap Power Supply Upgrade

Kit

3

External Storage Expansion Units

4

-

Form

Factor

00N6xxx

10

37L5857

37L0xxx

19K11xx

11

12

09N7296

Netfinity EXP200 Storage Expansion

Unit

5, 8

Rack (3U)

Netfinity EXP200 Rack-to-Tower

Conversion Kit

Netfinity EXP200 350 W Redundant

Power Supply

8

EXP300 Storage Expansion Unit

6, 8

EXP300 Rack-to-Tower Conversion

Kit

-

-

Rack (3U)

-

00N71xx

13

FAStT EXP500 Storage Expansion

Unit

7, 8

94G7448 Rack Power Cable Type C12 (3.7m)

8

Rack (3U)

-

1. Additional power may be required when installing a SCSI device in bay A or B. Configurations exceeding four SL hotswap hard disk drives and two PCI adapters require both Hot-Swap Power Supply Upgrade Kit P/N 37L6881 and at least one optional 250 W Hot-Swap Redundant Power Supply P/N 33L37xx. Example: 3 SL HS HDD’s plus 5 adapters - no additional power supply required. An optional SCSI cable is required. A two-drop terminated LVD SCSI cable is included with both Media Bay Tray and LVD Cable Kit P/N 10K2340 and Hot-Swap Power Supply Upgrade Kit P/N 37L6881.

2. Media Bay Tray and LVD Cable Kit P/N 10K2340 contains a two-drop terminated LVD SCSI cable and the hardware required to convert two half-high 5.25” removable media bays into two non-hot-swap 7200 RPM HDD bays.

3. Hot-Swap Power Supply Upgrade Kit P/N 37L6881 contains a hot-swap power backplane that supports installation for up to three hot-swap power supplies.

4. Select an optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

5. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and single hot-swap 350W power supply. Optional hot-swap

Netfinity EXP200 350W Redundant Power Supply (P/N 37L0075) provides redundancy.

6. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies.

7. FAStT EXP500 Storage Expansion Unit (P/N 00N71xx) includes dual hot-swap 350W power supplies.

8. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

9. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark, 63=Israel, 64=Italy, 65=South

Africa, 66=Switzerland, 67=United Kingdom&Arabia.

10. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

11. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,

079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

12.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

13. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

xSeries 230 / Netfinity 5100 Internal SCSI Cabling

The xSeries 230 and Netfinity 5100 contain a DASD backplane supporting six hot-swap, SCA-2 compliant drive bays. The backplane is connected to channel A of the integrated dual-channel, Ultra160 SCSI controller connector through a 16-bit LVD SCSI cable. If internal RAID support is required, this cable can be used to connect to a supported RAID adapter rather than the integrated SCSI controller. No external SCSI port is included.

A two-drop, 16-bit LVD SCSI cable with integrated terminator is also included with the Netfinity Hot-Swap Power Supply Expansion Kit P/N 37L6881.This cable is included in the expansion kit because installation of SCSI devices in bays A and B requires additional power. The two-drop cable supports up to two internal devices in these bays. This cable can be attached to channel B of the integrated dual-channel Ultra160 SCSI controller or to a supported SCSI adapter.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

28

Updated

17/10/00

29

Updated

17/10/00 xSeries 230 / Netfinity 5100 I/O Options

Part

Number

Description

19K0564

37L6086

37L6091

37L6080

37L6889

19K4646

02K3454

00N6881

19K11xx

20

19K11xx

21

19K1121

34L1501

34L0301

34L0701

Storage Controllers

1

Netfinity ServeRAID-3L Ultra2 SCSI Adapter II

2

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

3

ServeRAID-4L Ultra160 SCSI Controller

4

ServeRAID-4M Ultra160 SCSI Controller

5

ServeRAID-4H Ultra160 SCSI Controller

6

PCI Wide Ultra160 SCSI Adapter

15

PCI Wide Ultra SCSI Adapter

Fibre Storage Controller and Options

7

Netfinity FAStT Host Adapter

FAStT200 Storage Server

FAStT200 HA Storage Server

FAStT200 Redundant RAID Controller

Networking

8

Ethernet

Netfinity 10/100 Ethernet PCI Adapter 2

Netfinity Gigabit Ethernet SX Adapter

Token Ring

Token-Ring 16/4 PCIAdapter 2 with Wake on LAN

16

Communications

9

Adapter

Length

Full

Full

Full

Full

Full

Half

Half

Half

-

-

-

Half

Half

Half

PCI Support

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32/64-bit

-

-

-

32-bit

32/64-bit

32-bit

Slots

Supported

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

-

-

-

1...5

1...5

1...5

Exterior Connector Access

36L96xx

19

03K9309

36L9654

Systems Management

10

Netfinity Advanced System Management PCI Adapter

11

Netfinity Advanced System Management Interconnect Cable

Kit

13

Netfinity Advanced System Management Token-Ring

Connection

14

Full

-

-

32-bit

-

-

1...5

12

-

-

10L7368

Host Attach

Netfinity ESCON Adapter

17

Full 32-bit 1...5

18

1. xSeries 230 / Netfinity 5100 includes a dual-port, dual-channel Ultra160 SCSI controller for internal use only. No standard external port is available. See “Internal SCSI Cabling” for cabling alternatives.

2. Netfinity ServeRAID-3L Ultra2 SCSI Adapter II P/N 19K0564 provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

3. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and two external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8-mm VHDCI) providing a total of three external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

4. ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection. External connector is 0.8-mm VHDCI.

5. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external

Uoltra160 connectors (only two connectors may be utilised). External connectors are 0.8-mm VHDCI .

6. ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external

Ultra160 connectors (only four connectors may be utilised). External connectors are 0.8-mm VHDCI.

7. See Fibre Array Solutions section for additional configuration information.

8. xSeries 230 / Netfinity 5100 includes a full-duplex, 10/100 Mbps Ethernet PCI controller.

9. xSeries 230 / Netfinity 5100 includes two USB ports, two serial and one parallel port.

10. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into xSeries 230 / Netfinity 4500R works with Netfinity Director to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 36L96xx) and Netfinity Advanced System Management Interconnect Cable Kit (P/N

03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.

11. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter, which requires a separate power source. Provides an integrated

10/100 Ethernet port and a PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654).

12. A maximum quantity of one is supported.

13. Required for all xSeries / Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 1xX...4xX are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 36L96xx) includes the contents of this option.Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more

than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.

14 Contains an IBM Turbo 16/4 Token-Ring PCI card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter (P/N 36L96xx), and a PC Card to 9-pin

D-Shell cable which is routed to an available adapter slot opening (reduces available slots by one). The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and

Netfinity Advanced System Management Token-Ring Connection cannot be connected or used together.

15. PCI Wide Ultra160 SCSI Adapter P/N 19K4646 provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm VHDCI connector. Only one of the two connectors may be utilised.

16. The Wake on LAN function of this option is not supported by this server.

17. Provides an ESCON MIC and a DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.

18. A maximum of two ESCON adapters (installed in non-adjacent slots) are supported in a single server.

19. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi Arabia.

20.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English

31=South Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

21.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English,

45=South Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

xSeries 230 / Netfinity 5100 Power, Monitors, Accessories

Part Number

33L37xx

11

37L6881

94G7448

Description

Power

1,10

250 W Hot-Swap Redundant Power Supply

2, 10

Hot-Swap Power Supply Expansion Kit

3

Rack Power Cable Type C12 (3.7m)

10

Free Standing Uninterruptible Power Supply (UPS)

4

SUP102Y

SUP142Y

14RIxxx

13

30RIxxx

13

37L6862

T3347xx

12

31H2Nxx

12

T32N3xx

12

T274Axx

12

11AG1xx

12

APC Smart-UPS 1000

APC Smart-UPS 1400

APC Smart-UPS 1400RMB

5

APC Smart-UPS 3000RMB

5

APC Smart-UPS 5000RMB

6

Rack Mount Uninterruptible Power Supply (UPS)

4

Monitors

7

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

8

8

8

8

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

9

1. xSeries 230 / Netfinity 5100 include a single 250 W, hot-swap power supply and a single standard country power cord. Power supply redundancy may be achieved with the addition of optional

250 W Hot-Swap Redundant Supply P/N 33L37xx. Hot-Swap Power Supply Upgrade Kit P/N 37L6881 is required when optional power supplies are to be added. Redundancy for configurations of greater than 250 W requires installation of a second optional supply. Whenever devices are installed in bays A or B, both the expansion kit and a second power supply are required. Generally, configurations containing greater than six PCI adapters and HDDs, in any combination, will require the second power supply. To assist in determining when an additional power supply is required to preserve redundancy, a “Non-Redundant LED” is a standard feature.

2. 250 W Hot-Swap Redundant Power Supply P/N 33L37xx includes a single standard country power cord for connection to a low voltage wall outlet. Hot-Swap Power Supply Expansion Kit P/N

37L6881 must be installed prior to adding optional power supplies.

3. Hot-Swap Power Supply Expansion Kit P/N 37L6881 includes a hot-swap power backplane, terminated two-drop LVD SCSI cable, and mounting brackets for DLT tape drives. Required when installing a second power supply or devices in the 133-mm (5.25”) HH bays.

4. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

5. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

6. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

7. Netfinity 5100 uses an SVGA controller (S3 Savage4 chipset) with 8 MB of video memory.

8. Installation within a rack requires optional Monitor Compartment P/N 94G7444.

9. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

10. Rack Power Cable P/N 94G7448 (type C12 - one for each power supply), must be ordered for power connection of a Rack model to a high voltage UPS or PDU.

11. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark, 63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United Kingdom&Arabia.

12. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

13. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom,

EUR=Europe.

Part Number

37L6858

930842P

930842X

9306900

9306910

9306200

37L6888

94G7448

28L36xx

6

28L36xx

7

28L3675

Description

Conversion Kits

5Ux24D Tower-to-Rack Kit

Rack and NetBAY

1,8

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (includes perforated front door)

Netfinity NetBAY22

Netfinity Flat Panel Monitor Rack Mount Kit II

Rack Power Cable Type C12 (3.7m)

8

Keyboard and Mouse

2

Space Saver II Keyboard

3, 5

Preferred Keyboard (stealth black)

4

Sleek 2-Button Stealth Black Mouse

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

30

Updated

17/10/00

31

Updated

17/10/00

1. xSeries 230 / Netfinity 5100 rack models are housed in a 19” rack mountable drawer and require one of the racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported devices.

2. Tower models include both a keyboard and mouse. Rack models include neither.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

5. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

6 . Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/

Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

7. Where ‘ xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

8. The xSeries 230 / Netfinity 5100 ships with a standard country power cord. For connection of a Rack model to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

xSeries 230 / Netfinity 5100 Tape Options

Part

Number

Tape Drives

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

1

01K1325 20/40 GB 8-mm Internal SCSI Tape Drive

1

09N4040 20/40 GB DLT Internal SCSI Tape Drive

1

00N7990 40/80 GB DLT Internal SCSI Tape Drive

1

Bays

Supported

A, B

A, B

A/B

A/B

SCSI

Interface

(bit)

Form

Factor

16 Ultra2 LVD

16

8

16 Ultra2 LVD

16 Ultra2 LVD

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

133 mm

(5.25”) HH

133 mm

(5.25”) FH

133 mm

(5.25”) FH

133 mm

(5.25”) HH

Termination

Included

Y

N

N

N

N

68/50-pin

Converter Incl.

N/A

N/A

Y

N/A

Ext. Tape

Enclosures

10L7440,

03K8756

2

10L7440

3

,

03K8756

03K8705

3

,

03K8756

03K8705

03K8756

3

2

,

10L7440

03K8756

3

2

,

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

1

00N79xx

11

Tape Autoloaders

DLT Tape Autoloader

00N7992 120/240GB DDS/4 Tape Autoloader

1

A, B

N/A

A/B

16

16 Ultra2 LVD

Desktop

133 mm

(5.25”) FH

Y

N

N/A

-

N

-

03K8756

2

External Tape Libraries

4

00N79xx

12

DLT Tape Library 16

Desktop orRack

Y -

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

5

03K8705 DLT External SCSI Enclosure

6

03K8756 NetMEDIA Storage Expansion Unit EL

7

10L7113 NetMEDIA Systems Management Adapter

8

Associated Options

-

-

-

8/16

16

16

16 LVD

Desktop

Desktop

Rack

-

N

N

Y

N

N

N

N

N

-

-

-

03K8756

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

10K2340 Media BayTray and LVD Cable Kit

1,2,9

-

-

16 LVD/SE

16 LVD

Ext.

Int.

Y

Y

N

N

10L7440,

03K8705

-

37L6881

33L37xx

13

Netfinity Hot-Swap Power Supply Expansion

Kit

10

250 W Hot-Swap Redundant Power Supply

-

-

16 LVD

-

Int.

-

Y

-

N

-

-

-

Note: Additional power may be required when installing a SCSI device in bay A or B. Configurations exceeding four SL hot-swap hard disk drives and two PCI adapters require both Hot-Swap Power Supply

Expansion Kit P/N 37L6881 and at least one optional 250 W Hot-Swap Redundant Power Supply P/N 33L37xx. Example: 3 SL HS HDD’s plus 5 adapters - no additional power supply required. An optional

SCSI cable is required for attachment of media bay devices to Ultra160 controller B. No external SCSI port is available. External tape enclosures are supported by PCI Wide Ultra160 SCSI Adapter P/N

19K4646 which has an external 0.8-mm VHDCI connector.

1. Requires two-drop multi-mode terminated LVD SCSI cable included with either Media Bay Tray and LVD Cable Kit P/N 10K2340 or Hot-Swap Power Supply Expansion Kit P/N 37L6881.

2. LVD support for LVD devices requires installation of the 16-bit multi-mode terminated, two-drop, SCSI cable included with optional Media Bay Tray and LVD Cable Kit P/N 10K2340.

3. Requires 68-pin External Multimode LVD/SE SCSI terminator P/N 00N7956.

4. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

5. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin External

Multimode LVD/SE SCSI Terminator P/N 00N7956.

6. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of an External Multimode LVD/SE SCSI terminator P/

N 00N7956.

7. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

8. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

9. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

10. Hot-Swap Power Supply Expansion Kit P/N 37L6881 includes a hot-swap power backplane, and two-drop multi-mode terminated LVD SCSI cable. Required when installing a second power supply.

11. Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

12. Where ‘xx’ represents a country specific power cord code: Tower versions - 74=EU1, 75=Denmark, 76=India/South Africa, 77=UK, 78=Swiss, 79=Italy, 80=Israel: Rack versions - 81=EU1,

82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

13. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark, 63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United Kingdom&Arabia.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

xSeries 230 / Netfinity 5100 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

Part Number Description

851YExx

33L3123

37L6091

37L7201

01K1325

31H2Nxx

SUP102Y

37L6881

Netfinity 5100 933 MHz/256 KB, 128 MB ECC, OPEN, 40X, PCI

128 MB 133 MHz SDRAM ECC RDIMM II

ServeRAID-4L Ultra160 SCSI Controller

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

20/40 GB 8-mm Internal SCSI Tape Drive

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 1000

Hot-Swap Power Supply Expansion Kit

2

33L37xx 250 W Hot-Swap Redundant Power Supply

1. For a total of 256 MB of system memory.

2. For a total of 36.4 GB of RAID protected hot-swap, hot-spare internal storage.

1

Quantity

1

1

1

1

1

4

1

1

1

An internet server is a server that handles all requests from the Internet (intranet or extranet). Usually this type of server has the same characteristics as a file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (Firewall). In the case of an internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.

With this in mind the xSeries 230 was selected to provide an affordable price point for the growing internet server market, 256 MB of system memory (expandable to 4 GB, and availability features such as RAID protected internal hot-swap storage and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the internet. Usually fast Ethernet routers are used, but if other methods are used, you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

File and Print Server

Part Number

K861Yxx

33L3123

37L6091

37L7201

01K1325

31H2Nxx

SUP102Y

37L6881

33L37xx

APC Smart-UPS 1000

Hot-Swap Power Supply Expansion Kit

250 W Hot-Swap Redundant Power Supply

1. For a total of 256 MB of system memory.

2. For a total of 45.5 GB of RAID protected hot-swap, hot-spare internal storage.

Description xSeries 230 1 GHz/256 KB, 128 MB ECC, OPEN, 40X, PCI

128 MB 133 MHz SDRAM ECC RDIMM II

1

ServeRAID-4L Ultra160 SCSI Controller

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

2

20/40 GB 8-mm Internal SCSI Tape Drive

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

Quantity

1

1

1

1

5

1

1

1

1

A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing environment, but doesn’t require the high end performance and fault tolerance properties of larger servers.

The sample configuration above consists of an xSeries 230 with 256 MB of memory (expandable to 4 GB) and 45.5 GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.

The configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected during power surges and outages.

Rack Mounted Application Server

Part Number Description

85RYExx

19K4631

33L3125

37L6080

37L7201

01K1325

31H2Nxx

14RIxxx

33L37xx

37L6881

Netfinity 5100 933 MHz/256 KB, 128 MB ECC, OPEN, 40X, PCI (Rack 5U)

933 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

256 MB 133 MHz SDRAM ECC RDIMM II

1

ServeRAID-4M Ultra160 SCSI Controller

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

2

20/40 GB 8-mm Internal SCSI Tape Drive

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 1400RMB

9306200

250 W Hot-Swap Redundant Power Supply

Hot-Swap Power Supply Expansion Kit

Industry Standard 19” Rack, EIA-310D, min. depth of 28” (711 mm)

Netfinity NetBAY22

28L36xx

28L3645

Space Saver II Keyboard

Blank Filler Kit

1. For a total of 384 MB of system memory.

2. For a total of 36.4 GB of usable RAID 5 storage (45.5 GB total disk).

Quantity

1

1

1

5

1

1

1

1

1

1

1

1

2

An application server differs from a file and print server in that it has a higher workload, in providing application serving requirements for users. With this in mind, the xSeries 230 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 384 MB of system memory (expandable to 4 GB), and availability features such as battery-backed cache, RAID protected internal hot-swap storage and power protection with an APC Smart-UPS.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

32

Updated

17/10/00

33

Updated

17/10/00

IBM xSeries 240 and Netfinity 5600

xSeries 240 / Netfinity 5600 At-A-Glance Chart

xSeries 240

K481Yxx

K48RYxx

1

-

-

1 GHz 1/2 256

1 GHz 1/2 256

256MB

(R)/4GB

256MB

(R)/4GB

Tower 2/3

Rack(5U) 2/3

P,

S,H,F

P,

S,H,F

S-Power

4

S-Fans

S-Power

4

S-Fans

Y 10/100

Y 10/100

D,U2

D,U2

4/2 0/218.4 GB 40X- 17X 10/8 5/5

4/2 0/218.4 GB 40X- 17X 10/8 5/5

Netfinity 5600

441YExx

44RYExx

451YExx

45RYExx

461YExx

46RYExx

471YExx

47RYExx

1

1

1

1

24/10/00

24/10/00

-

-

-

-

-

-

733

733

800

800

866

866

933

933

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

256

256

256

256

256

256

256

256

256MB

(R)/4GB

256MB

(R)/4GB

256MB

(R)/4GB

256MB

(R)/4GB

256MB

(R)/4GB

256MB

(R)/4GB

256MB

(R)/4GB

256MB

(R)/4GB

Tower

Rack

(5U)

Tower

Rack

(5U)

Tower

Rack

(5U)

Tower

Rack

(5U)

2/3

2/3

2/3

2/3

2/3

2/3

2/3

2/3

P,

S,H,F

P,

S,H,F

P,

S,H,F

P,

S,H,F

P,

S,H,F

P,

S,H,F

P,

S,H,F

P,

S,H,F

S-Power

4

S-Fans

S-Power

4

S-Fans

S-Power

4

S-Fans

S-Power

4

S-Fans

S-Power

4

S-Fans

S-Power

4

S-Fans

S-Power

S-Fans

S-Power

S-Fans

4

4

Y

Y

Y

Y

Y

Y

Y

Y

10/100

10/100

10/100

10/100

10/100

10/100

10/100

10/100

D,U2

D,U2

D,U2

D,U2

D,U2

D,U2

D,U2

D,U2

4/2

4/2

4/2

4/2

4/2

4/2

4/2

4/2

0/218.4 GB

0/218.4 GB

0/218.4 GB

0/218.4 GB

0/218.4 GB

0/218.4 GB

0/218.4 GB

0/218.4 GB

40X- 17X

40X- 17X

40X- 17X

40X- 17X

40X- 17X

40X- 17X

40X- 17X

40X- 17X

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Power, Monitor & Accessories” for supported IBM racks.

2. Intel Pentium III processor with advanced transfer (full speed) L2 cache and 133 Mhz Front-Side Bus.

3. High-speed, 133 MHz SDRAM.

4. Robust configurations may require optional 250W Hot-Swap Redundant Power Supply P/N 33L37xx for redundancy. See Power, Monitor, Accessories section for additional information.

5. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

6. Not available from IBM after this date. Business Partner inventory may be available.

10/8

10/8

10/8

10/8

10/8

10/8

10/8

10/8

5/5

5/5

5/5

5/5

5/5

5/5

5/5

5/5 xSeries 240 / Netfinity 5600 Processor Upgrades

Part Number Processor Upgrades with 256 KB Cache

(Full Speed)

SMP Support

1

Processor Speed Upgrade

2

00N7943

10K2338

19K4630

19K4631

Netfinity 733 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 800 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 866 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 933 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

4xY

5xY

6xY

7xY

All 1...3xY

All 1...4xY

All 1...5xY

All 1...6xY

19K4640

1 GHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache

Pentium III Processor

8xY -

1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

To access information on the World Wide Web, use address: http://www.pc.ibm.com

34

Updated

17/10/00

35

Updated

17/10/00 xSeries 240 / Netfinity 5600 Memory Configurator

Install largest RDIMM in socket 4 (J1) with subsequent RDIMMs in the following order: J4,

J3, J2.

Standard Memory

256MB Models

Total Memory

1

256 MB

384 MB

512 MB

640 MB

896 MB

1024 MB

1152 MB

1664 MB

2048 MB

2304MB

3200 MB

3328 MB

4096 MB (max)

-

-

1

-

-

-

128MB

-

-

1

-

1

-

1

-

-

1

1

-

-

256MB

1

1

1

-

-

1

1

-

-

-

1

-

-

512MB

1

1

1

-

-

-

-

2

-

1

1

3

4

2

1GB

-

-

-

-

-

-

-

Memory RDIMMs to be added

This table does not represent all possible memory configurations.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. Requires removal of standard memory.

Part Number Memory Description

1

33L3058

33L3060

33L3062

128 MB, 133 MHz SDRAM ECC RDIMM

256 MB, 133 MHz SDRAM ECC RDIMM

512 MB, 133 MHz SDRAM ECC RDIMM

33L3064 1 GB, 133 MHz SDRAM ECC RDIMM

1. Install largest RDIMM in socket 4 (J1) with subsequent RDIMMs in the following order: J4, J3, J2.

xSeries 240 / Netfinity 5600 Internal Hard Disk Drive and External Storage Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

2

18.2 GB

(P/N 37L7202)

2

36.4 GB

(P/N 37L7203)

2

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7204)

2

18.2 GB

(P/N 37L7205)

2

36.4 GB

(P/N 37L7206)

0 GB

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

1

2

3

4

5

Standard on Base Models

-

1

-

2

-

-

-

-

1

-

1

2

3

4

5

Standard on Base Models

-

1

-

2

-

54.6 GB

72.8 GB

91 GB

109.2 GB

145.6 GB

182 GB

218.4 GB

(max.)

6

-

-

-

-

-

-

3

4

5

6

-

-

-

4

5

6

-

2

-

3

3

3

3

6

-

-

-

-

-

-

3

4

5

6

-

-

-

-

2

-

3

4

3

5

3

6

3

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

2.Netfinity 5600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

-

-

-

1

-

2

Bay

A

B

-

-

C...H

Form

Factor

133 mm

(5.25”)

133 mm

(5.25”)

133 mm

(5.25”)

89 mm

(3.5”)

HS

Height

HH

1

HH

1

HH

SL

SL

2

Front

Access

Yes

Yes

Yes

Yes

Yes

Usage

Open

Open

IDE CD-

ROM

Diskette

Open

Part

Number

37L7201 9.1 GB Ultra160 SCSI Hot-Swap SL HDD

37L7202

37L7203

37L7204

Description

Ultra160 Hard Disk Drives (HDD)

1

18.2 GB Ultra160 SCSI Hot-Swap SL

HDD

36.4 GB Ultra160 SCSI Hot-Swap SL

HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-Swap

SL HDD

RPM Height

7200

7200

7200

10,000

SL

SL

SL

SL

Bays

Supported

C...H

C...H

C...H

C...H

Max.

Qty.

6

6

6

6

1. Two half-high (HH) bays can be combined to support a single full-high

(FH) device

2. Two slim-line (SL) bays can be combined to support a single half-high

(HH) device.

Tower Model View

Removable Media (RM)

A

B

CD-ROM

Hot-Swap

(HS)

C

D

E

F

G

H

37L7205

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap

SL HDD

10,000 SL C...H

6

37L7206

19K0655

19K0656

36.4 GB 10K-4 Ultra160 SCSI Hot-Swap

SL HDD

9.1 GB 15K-rpm Ultra160 SCSI Hot-Swap

HDD

18.2 GB 15K-rpm Ultra160 SCSI Hot-

Swap HDD

10,000

15000

15000

SL

SL

SL

Non-Hot-Swap Internal Hard Disk Drives (HDD)

20L0553 9.1 GB Wide Ultra2 SCSI HDD

2

20L0554 18.2 GB Wide Ultra2 SCSI HDD

2

7200

7200

SL

SL

Associated Options

C...H

C...H

C...H

A, B

2

A, B

2

6

6

6

2

2

10K2340 Media Bay Tray and LVD Cable Kit

External Storage Expansion Units

3

00N6xxx

8

37L5857

Netfinity EXP200 Storage Expansion

Unit

4, 7

Netfinity EXP200 Rack-to-Tower

Conversion Kit

-

Form Factor

Rack (3U)

Tower

A/B 1

For clarity purposes, bay labels in these diagrams are for reference by the accompanying tables and are not the actual labels. Refer to the documentation shipped with the system for further details on actual labels.

Rack Model View

H G F E D

Removable Media (RM)

C

A

B

CD-ROM

Diskette

37L0xxx

9

19K11xx

10

Netfinity EXP200 350 W Redundant

Power Supply

7

EXP300 Storage Expansion Unit

5, 7

09N7296 EXP300 Rack-to-Tower Conversion Kit

00N71xx

11

FAStT EXP500 Storage Expansion Unit

6, 7

94G7448 Rack Power Cable Type C12 (3.7m)

7

-

Rack (3U)

-

Rack (3U)

-

1. Netfinity 5600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

2. Requires Media Bay Tray and LVD Cable Kit P/N 10K2340. Media Bay Tray and LVD Cable Kit converts two half-high

5.25” removable media bays into two non-hot-swap HDD bays.

3. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see Appendix D: Cables-

Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

4. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply. Optional hot-swap

Netfinity EXP 350 W Redundant Power Supply P/N 37L0xxx provides redundancy. To convert and EXP200 to a tower form factor, Netfinity EXP200 Rack-to-Tower Conversion Kit P/N 37L5857 is required.

5. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500 W redundant power supplies. To convert an EXP300 to a tower form factor, Netfinity EXP300 Rack-to-Tower Conversion Kit P/N 09N7296 is required.

6. FAStT EXP500 Storage Expansion Unit P/N 00N71xx includes dual hot-swap 350 W power supplies.

7. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or PDU).

Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

8. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South Africa/

English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication Country Kits are included throughout.

9. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/

English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

10.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/English,

58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication Country Kits are included throughout.

11. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/Language

Line Cords/Publications are included as indicated.

xSeries 240 / Netfinity 5600 Internal SCSI Cabling

The xSeries 240 and Netfinity 5600 contain a backplane supporting six hot-swap drive bays. The backplane is connected to the integrated dual channel, wide Ultra2 SCSI controller connector through a 16-bit LVD SCSI cable. If internal RAID support is required, this cable can be used to connect to a supported RAID adapter rather than the integrated SCSI controller. A two-drop, 16-bit SCSI cable with integrated terminator is also included with the server to support up to two internal removable media devices. This cable can be attached to the integrated SCSI controller if a RAID adapter is used to support the internal hot-swap drive bays. It can also be used to attach to a supported SCSI adapter if the integrated Ultra2 SCSI controller is utilised for the hot-swap bays. The second channel is available through an industry-standard 0.8-mm very high density connector interface

(VHDCI) located on the rear panel for external use.

To access information on the World Wide Web, use address: http://www.pc.ibm.com

36

Updated

17/10/00

37

Updated

17/10/00 xSeries 240 / Netfinity 5600 I/O Options

Part

Number

Description

Storage Controllers

1

01K7364 Netfinity ServeRAID-3L Ultra2 SCSI Adapter

3

37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

4

37L6091 ServeRAID-4L Ultra160 SCSI Controller

5

37L6080 ServeRAID-4M Ultra160 SCSI Controller

6

37L6889 ServeRAID-4H Ultra160 SCSI Controller

7

19K4646 PCI Wide Ultra160 SCSI Adapter

8

02K3454 PCI Fast/Wide Ultra SCSI Adapter

Fibre Storage Controller and Options

9

00N6881 Netfinity FAStT Host Adapter

19K11xx

22

FAStT200 Storage Server

19K11xx

23

FAStT200 HA Storage Server

19K1121 FAStT200 Redundant RAID Controller

Networking

10

Ethernet

34L1501 Netfinity 10/100 Ethernet PCI Adapter 2

09N9901 10/100 EtherLink Server Adapter by 3Com

34L0301 Netfinity Gigabit Ethernet SX Adapter

Adapter

Length

Full

Full

Full

Full

Full

Half

Half

Half

-

-

-

PCI Support

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32/64-bit

-

-

-

Slots

Supported

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

-

-

-

Hot-

Plug

X

X

X

-

-

X

X

X

-

-

-

2

Rack Model

Half

Half

Half

32-bit

32-bit

32/64-bit

1...5

1...5

1...5

X

X

X

Token Ring

34L5001 16/4 Token-Ring PCI Management Adapter

20

34L5201 High-Speed 100/16/4 Token-Ring PCI Management Adapter

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

20

Communications

11

37L14xx Serial I/O SST 8, 16 and 128 Port Adapters

12

Systems Management

13

36L96xx

21

Netfinity Advanced System Management PCI Adapter

14

03K9309 Netfinity Advanced System Management Interconnect Cable Kit

16

36L9654 Netfinity Advanced System Management Token-RIng Connection

17

Half

Half

Half

Full

-

-

32-bit

32-bit

32-bit

Half 32-bit

32-bit

-

-

1...5

1...5

1...5

1...5

12

1...5

15

-

-

-

-

-

X

X

X

-

Host Attach

10L7368 Netfinity ESCON Adapter

18

Full 32-bit 1...5

19

-

1. xSeries 240 / Netfinity 5600 has two integrated Wide Ultra2 SCSI channels. One is internal and the other is external with a 0.8-mm Very High Density Connection Interface (VHDCI).

2. Three of the five PCI slots are 32/64-bit hot-plug capable using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat.

3. Netfinity ServeRAID-3L Ultra2 SCSI Adapter P/N 01K7364 provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

4. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8mm VHDCI connector) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

5.ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection.

External connectors are 0.8-mm VHDCI..

6. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external Ultra160 connectors (only two connectors may be utilized). External connectors are 0.8-mm VHDCI.

7.ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external Ultra160 connectors

(only four connectors may be utilised). External connectors are 0.8-mm VHDCI.

8. PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm

VHDCI connector. Only one of the two connectors may be utilised.

9. See Fibre Array Solutions section for additional configuration information.

10. xSeries 240 / Netfinity 5600 has an integrated 10/100 PCI Ethernet Controller.

11. xSeries 240 / Netfinity 5600 includes two USB ports, three high-speed serial/asynchronous ports, (two NS16550A compatible, one for the Advanced System Management Processor), and one high-speed (up to 2 MB/sec. data transfer speed) bi-directional parallel port supporting devices using ECP/EPP/SSP protocols adhering to the IEEE 1284 standard.

12. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416) may be installed.

13. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into xSeries 240 / Netfinity 5600 works with Netfinity Director to provide significant system management function.

When used with optional Netfinity Advanced System Management PCI Adapter (P/N 36L96xx) and Netfinity Advanced System Management Interconnect Cable Kit (P/N 03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.

14. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter which requires a separate power source. Provides an integrated 10/100 Ethernet port and PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654).

15. A maximum quantity of one is supported.

16. Required for all xSeries and Netfinity servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 1xX...4xX are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 36L96xx) includes the content of this option.

Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.

17. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter (P/N 36L96xx), and a PC Card to 9-pin D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter integrated Ethernet port and Netfinity Advanced System Management Token-Ring Connection cannot be connected or used together.

18. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.

19. A maximum of two ESCON adapters (installed in non-adjacent slots) are supported in a single server.

20. The Wake on LAN function of this option is not supported by this server.

21. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi Arabia.

22.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English 31=South

Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

23.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South

Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

xSeries 240 / Netfinity 5600 Power, Monitors, Accessories

Part Number

33L37xx

10

94G7448

Description

Power

1,8

250 W Hot-Swap Redundant Power Supply

8

Rack Power Cable Type C12 (3.7m)

8

Free Standing Uninterruptible Power Supply (UPS)

2

SUP102Y

SUP142Y

14RIxxx

11

30RIxxx

11

37L6862

T3347xx

9

31H2Nxx

9

T32N3xx

9

T274Axx

9

11AG1xx

9

APC Smart-UPS 1000

APC Smart-UPS 1400

Rack Mount Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 1400RMB

3

APC Smart-UPS 3000RMB

3

APC Smart-UPS 5000RMB

4

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

6

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

6

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

6

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

7

1. xSeries 240 / Netfinity 5600 include two 250W hot-swap power supplies, each with its own standard country power cord. These standard power supplies are sufficient to operate fully configured systems; however optional 250W Hot-Swap Redundant Power Supply P/N 33L37xx is required to preserve redundancy if any of the following are exceeded:

Single Processor Configuration: Six SL hard disk drive (HDDs) and two PCI adapters (1 HH HDD = 2 SL, 1 tape = 2 SL, 1 PCI adapter = 2 SL)

e.g. To preserve power supply redundancy with 3 PCI adapters only 4 SL HDDs can be installed before an optional power supply is required.

Dual Processor Configuration: Four SL hard disk drives (HDDs) and two PCI adapters (1 HH HDD = 2 SL, 1 tape = 2 SL, 1 PCI adapter = 2 SL)

A “non-redundant” LED on the system unit will indicate when 250W has been exceeded. 250 W Hot-Swap Redundant Power Supply (P/N 33L37xx) includes a standard country power cord which requires an additional power source. An independent power source such as a second UPS or second circuit is not required.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. xSeries 240 / Netfinity 5600 use an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.

6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

8. Rack Power Cable P/N 94G7448 (type C12 - one for each power supply), must be ordered for power connection of a Rack model to a high voltage UPS or PDU.

9. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

10. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark, 63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United

Kingdom&Arabia.

11. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,

UKM=United Kingdom, EUR=Europe.

Part Number Description

Conversion Kits

37L6858 5Ux24D Tower-to-Rack Kit

Rack and NetBAY

1,8

930842P

930842X

9306900

9306910

9306200

37L6888

94G7448

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (includes perforated front door)

Netfinity NetBAY22

Netfinity Flat Panel Monitor Rack Mount Kit II

Rack Power Cable Type C12 (3.7m)

8

Keyboard and Mouse

2

Space Saver II Keyboard

3, 5

Preferred Keyboard (stealth black)

4

Sleek 2-Button Stealth Black Mouse

28L36xx

6

28L36xx

7

28L3675

1. xSeries 240 / Netfinity 5600 rack models are housed in a 19” rack mountable drawer and require one of the racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported devices.

2. Tower models include both a mouse and a keyboard. Rack models include neither.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

5. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

6 . Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N

19K3831=Switzerland, 19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

7. Where ‘ xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

8. The xSeries 240 / Netfinity 5600 ships with a standard country power cord. For connection of a Rack model to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448

(type C12), must be ordered.

To access information on the World Wide Web, use address: http://www.pc.ibm.com

38

Updated

17/10/00

39

Updated

17/10/00 xSeries 240 / Netfinity 5600 Tape Options

Part

Number

Tape Drives

09N4042 10/20 GB NS Internal SCSI Tape Drive

1

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

2

01K1325 20/40 GB 8-mm Internal SCSI Tape Drive

1

09N4040 20/40 GB DLT Internal SCSI Tape Drive

1

00N7990 40/80 GB DLT Internal SCSI Tape Drive

2

Bays

Supported

A, B

A, B

A, B

A/B

A/B

SCSI

Interface

(bit)

Form

Factor

8

16 Ultra2 LVD

16

8

16 Ultra2 LVD

16 Ultra2 LVD

89 mm

(3.5”) SL or

133 mm

(5.25”) HH

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

133 mm

(5.25”) HH

133 mm

(5.25”) FH

133 mm

(5.25”) FH

133 mm

(5.25”) HH

Termination

Included

Y

Y

N

N

N

N

68/50-pin

Converter Incl.

Y

N/A

N/A

Y

N/A

Ext. Tape

Enclosures

10L7440

10L7440,

03K8756

3

10L7440

4

,

03K8756

03K8705

4

,

03K8756

03K8705

03K8756

4

3

,

10L7440

03K8756

4

3

,

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

2

00N79xx

11

Tape Autoloaders

DLT Tape Autoloader

A, B N/A

00N7992 120/240GB DDS/4 Tape Autoloader

2

N/A

A/B

16

16 Ultra2 LVD

Desktop

133 mm

(5.25”) FH

Y

N

-

N/A

-

03K8756

3

External Tape Libraries

5

00N79xx

12

DLT Tape Library 16

Desktop orRack

Y -

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

6

03K8705 DLT External SCSI Enclosure

7

03K8756 NetMEDIA Storage Expansion Unit EL

8

10L7113 NetMEDIA Systems Management Adapter

9

Associated Options

-

-

-

8/16

16

16

16 LVD

Desktop

Desktop

Rack

-

N

N

Y

N

N

N

N

N

-

-

-

03K8756

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

10K2340 Media BayTray and LVD Cable Kit

2,3,10

-

-

16 LVD/SE

16 LVD

Ext.

Int.

Y

Y

N

N

10L7440,

03K8705

-

Note: Netfinity 5600 includes a wide two-drop single-ended terminated cable which can be used for attachment of internal tape drives to the onboard Ultra2 controller when the hot-swap backplane is attached to a RAID controller. If LVD support is required, an optional LVD cable must be ordered. An external Ultra2 SCSI port is available with a 0.8-mm VHDCI connector. External tape enclosures are supported by the standard external SCSI port or PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) which has an external 0.8-mm VHDCI connector.

1. Non-RAID Configurations: Requires PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) which contains a five-drop multi-mode terminated LVD SCSI cable.

2. RAID configurations: Configurations where the hot-swap backplane is cabled to a RAID controller, require the two-drop multi-mode terminated LVD SCSI cable included with Media Bay Tray and LVD

Cable Kit (P/N 10K2340) for support of LVD devices in LVD mode. Use of the included single-ended terminated cable with an LVD device will be limited to single-ended SCSI rules.

3. LVD support for LVD devices requires installation of the 16-bit multi-mode terminated, two-drop, SCSI cable included with optional Media Bay Tray and LVD Cable Kit (P/N 10K2340).

4. Requires 68-pin External Multimode LVD/SE SCSI terminator (P/N 00N7956).

5. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

6. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination

or 68-pin External Multimode LVD/SE SCSI Terminator (P/N 00N7956).

7. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of an External Multimode LVD/SE SCSI terminator (P/

N 00N7956).

8. NetMEDIA Storage Expansion Unit EL (P/N 03K8756) is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

9. NetMEDIA Systems Management Adapter (P/N 10L7113) may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

10. Media Bay Tray and LVD Cable Kit (P/N 10K2340) includes an internal two-drop multi-mode terminated LVD SCSI cable.

11 . Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

12 . Where ‘xx’ represents a country specific power cord code: Tower versions - 74=EU1, 75=Denmark, 76=India/South Africa, 77=UK, 78=Swiss, 79=Italy, 80=Israel: Rack versions - 81=EU1,

82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

xSeries 240 / Netfinity 5600 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Part Number

471YExx

33L3060

37L7201

37L7205

01K1325

37L6091

33L37xx

31H2Nxx

SUP102Y

High Availability Application Server

Description

Netfinity 5600 933 MHz/256 KB, 256 MB ECC, Open, 40X, PCI

256 MB, 133 MHz SDRAM ECC RDIMM

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

20/40 GB 8-mm Internal SCSI Tape Drive

ServeRAID-4L Ultra160 SCSI Controller

250 W Hot-Swap Redundant Power Supply

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

6

APC Smart-UPS 1000

Quantity

1

1

1

1

2

4

1

1

1

Usage

-

512 MB total system memory

9.1 mirrored for NOS

36 GB RAID 5 with hot-spare

-

RAID 1 for OS, RAID 5 for data

Full power redundancy

UPS

This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and UPS for power even during a blackout, this server represents the leading edge in high availability. An internal tape drive is included to back up that all important asset...data. A modem could be included to allow out-of-band (non-

LAN) system management utilizing the integrated Netfinity Advanced System Management Processor.

Part Number

K481Yxx

37L7204

01K1325

37L6889

33L37xx

31H2Nxx

SUP102Y

High Availability File Server

Description xSeries 240 1 GHz/256KB, 256 MB ECC, Open, 40X, PCI

9.1 GB 10K-4 Ultra2 SCSI Hot-Swap SL HDD

20/40 GB 8-mm Internal SCSI Tape Drive

ServeRAID-4H Ultra160 SCSI Controller

250 W Hot-Swap Redundant Power Supply

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

6

APC Smart-UPS 1000

Quantity

1

1

1

1

1

1

6

Usage

-

45 GB available disk and one hot spare

RAID 5 array, with hot-spare

Full power redundancy

-

-

This tower model is configured to meet the need of server consolidation. Many businesses are trying to get their arms around the dispersed departmental servers that have grown up around the enterprise. By moving multiple servers onto one platform there is only one system to manage, both hardware and software. There is potentially less expensive for service, software licenses, etc., and there is no need to worry about putting all your eggs in one basket because the xSeries240 is designed for high availability. This configuration includes 56

GB of internal HDD storage, features a third power supply which provides fully redundant power, a UPS to help protect the system against a momentary electricity loss, and an internal tape drive that backs up, up to 40 GB per tape...in addition to all the standard features of the xSeries 240.

To access information on the World Wide Web, use address: http://www.pc.ibm.com

40

Updated

17/10/00

41

Updated

17/10/00

IBM xSeries 330

xSeries 330 At-A-Glance Chart

K411Yxx

1

K431Yxx

1

K441Yxx

1

K451Yxx

1

-

-

-

-

800

866

933

1GHz

1/2

1/2

1/2

1/2

256

256

256

256

256MB(R)/4GB

256MB(R)/4GB

256MB(R)/4GB

256MB(R)/4GB

Rack(1U)

Rack(1U)

Rack(1U)

Rack(1U)

1/1

1/1

1/1

1/1

H

H

H

H

Y

Y

Y

Y

10/100 U160

10/100 U160

10/100 U160

10/100 U160

-

-

-

-

0/72.8GB

24X-10X 4/2

0/72.8GB

24X-10X 4/2

0/72.8GB

24X-10X 4/2

0/72.8GB

24X-10X 4/2

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “xSeries 330 Power, Monitor & Accessories” for supported IBM racks.

2. Intel Pentium III processor with advanced transfer (full speed) L2 cache and 133 MHz Front-Side Bus (FSB).

3. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

xSeries 330 Processor Upgrades

Part Number Processor Upgrades with 256 KB Cache

(Full Speed)

SMP

Support

1

Processor Speed

Upgrade

2

10K3810

10K3806

10K0052

800 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor

866 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor

933 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor

11Y

31Y

41Y

-

11Y

11Y/31Y

10K0053 1 GHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor 51Y 11Y/31Y/41Y

1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

2/2

2/2

2/2

2/2

Part Number Memory Description

1

33L3142

33L3144

128 MB, 133 MHz SDRAM ECC RDIMM II

256 MB, 133 MHz SDRAM ECC RDIMM II

33L3146

33L3152

512 MB, 133 MHz SDRAM ECC RDIMM II

1 GB, 133 MHz SDRAM ECC RDIMM II

1. Memory RDIMMs must be installed in sequence from RDIMM connector 1 through connector 4. RDIMM size is not relevent.

xSeries 330 Memory Configurator

Total Memory

1

256 MB

(1 x 256)

Models

384MB

512 MB

128 MB

(33L3123)

1

2 or

Quantity of RDIMMs Added

256 MB

(33L3125)

512 MB

(33L3127)

-

1

-

-

1 GB

(33L3129)

-

-

640 MB 3 -

768 MB

1024 MB

1280 MB

1792 MB

2048 MB

-

-

-

-

-

2 or

-

-

3

-

1

-

2 or

3

4

2

-

-

-

-

1

2304 MB 2

3328 MB

4096 MB (max)

-

-

-

-

-

-

3

4

2

This table does not represent all possible memory configurations. Memory modules may vary in price per MB.

Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. Requires removal of standard memory.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

42

Updated

17/10/00

43

Updated

17/10/00 xSeries 330 Internal Hard Disk Drive and External Storage Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

18.2 GB

(P/N 37L7202)

36.4 GB

(P/N 37L7203)

0 GB

9.1 GB

18.2 GB

36.4 GB

1

2 or

-

Standard on Base Models

-

1

2 or

72.8 GB -

This table does not represent all possible hard drive configurations.

-

-

1

2

1

2 or

-

-

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7204)

18.2 GB

(P/N 37L7205)

Standard on Base Models

-

1

2 or

-

36.4 GB

(P/N 37L7206)

-

-

1

2

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

Diskette / CD-ROM Bay 1 Bay 2

Bay Form Factor Height

1

2

1

89 mm

(3.5”)

89 mm

(3.5”)

HS

HS

1. Boot drive should be located in bay 1.

Front

Access

Yes

Yes

Usage

Open

Open

Part

Number

Description RPM Height Bays

Supported

Max.

Qty.

37L7201

37L7202

37L7203

37L7204

37L7205

Ultra160 Hard Disk Drives

(HDD)

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap SL

HDD

36.4 GB Ultra160 SCSI Hot-Swap SL

HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

7200

7200

7200

10,000

10,000

SL

SL

SL

SL

SL

1...2

1...2

1...2

1...2

1...2

2

2

2

2

2

37L7206

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

External Storage Expansion

Units

1

10,000 SL

Form Factor

1...2

2

00N6xxx

37L0xxx

6

7

Netfinity EXP200 Storage Expansion

Unit

2, 5

Netfinity EXP200 350 W Redundant

Power Supply

5

EXP300 Storage Expansion Unit

3, 5

Rack (3U)

-

19K11xx

8

Rack (3U)

00N71xx

9

FAStT EXP500 Storage Expansion

Unit

4, 5

94G7448 Rack Power Cable Type C12 (3.7m)

5

Rack (3U)

-

1. xSeries 330 does not include an external SCSI connector. Select an optional SCSI controller and then refer to Appendix

D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

2. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply. Optional hotswap Netfinity EXP200 350W Redundant Power Supply (P/N 37L0xxx) provides redundancy.

3. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies.

4. FAStT EXP500 Storage Expansion Unit (P/N 00N71xx) includes dual hot-swap 350W power supplies.

5. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

6. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

7. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/

English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

8.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

9. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

xSeries 330 Internal SCSI Cabling

xSeries 330 contains a DASD backplane supporting two hot-swap, SCA-2 compliant drive bays. The backplane is connected to one of the internal connectors of the integrated

Ultra160 SCSI controller through a 16-bit LVD SCSI cable. If internal RAID is required, the cable can be attached to the internal connector of the optional RAID adapter. The cable is of sufficient length to attach to adapters in slot 1 but not slot 2.

In configurations where external SCSI device attachment is required, a supported SCSI adapter or ServeRAID controller must be installed.

xSeries 330 I/O Options

Part

Number

Description

Storage Controllers

1

37L6091 ServeRAID-4L Ultra160 SCSI Controller

2

37L6080 ServeRAID-4M Ultra160 SCSI Controller

3

37L6889 ServeRAID-4H Ultra160 SCSI Controller

4

19K4646 PCI Wide Ultra160 SCSI Adapter

5

02K3454 PCI Fast/Wide Ultra SCSI Adapter

6

Fibre Storage Controller and Options

7

00N6881 Netfinity FAStT Host Adapter

19K11xx

14

FAStT200 Storage Server

19K11xx

15

FAStT200 HA Storage Server

19K1121 FAStT200 Redundant RAID Controller

Networking

8

Ethernet

34L0301 Netfinity Gigabit Ethernet SX Adapter

19K4401 Netfinity Gigabit Ethernet Adapter

09N9901 10/100 EtherLink Server Adapter by 3Com

34L4601 Netfinity 10/100 Ethernet Security Adapter

Adapter

Length

Full

Full

Full

Half

Half

Half

-

-

-

PCI Support

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32/64-bit

-

-

-

Slots

Supported

1

1

1

1, 2

1, 2

1, 2

-

-

-

Half

Half

Half

Half

32/64-bit

32/64-bit

32-bit

32/64-bit

1, 2

1, 2

1, 2

1, 2

Token Ring

34L0701 Token-Ring 16/4 PCI Adapter2 with Wake on LAN

9

34L5001 16/4 Token-Ring PCI Management Adapter

9

34L5201 High-Speed 100/16/4 Token-Ring PCI Management Adapter

Communications

10

37L14xx Serial I/O SST 8, 16 and 128 port adapters

11

Systems Management

12

36L96xx

13

Netfinity Advanced System Management PCI Adapter

Half

Half

Half

Half

32-bit

32-bit

32-bit

32-bit

1, 2

1, 2

1, 2

1, 2

Exterior

Connector

Access

Full 32-bit 1

03K9309

36L9654

Netfinity Advanced System Management Interconnect Cable

Kit

Netfinity Advanced System Management Token-Ring

Connection

-

-

-

-

-

-

1. xSeries 330 has an integrated single channel Ultra160 SCSI Controller.

2. ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection. External connector is 0.8-mm VHDCI.

3. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two external 0.8-mm VHDCI

Ultra160 connectors.

4. ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz Power PC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external

Ultra160 connectors (only four connectors may be utilized). External connectors are 0.8-mm VHDCI.

5. PCI Wide Ultra160 SCSI Adapter P/N 19K4646 provides a single channel with one internal connector and one external 0.8-mm VHDCI Ultra160 connector. Support for external SCSI devices only. A five-drop terminated LVD SCSI cable is included but not supported for use in this server.

6. For use in supporting external SCSI devices such as tape drives.

7. See the Fibre Array Solutions section for additional configuration information.

8. xSeries 330 includes dual full-duplex, 10/100 Mbps Ethernet controllers.

9. The Wake on LAN function of this option is not supported by this server.

10. xSeries 330 includes two USB ports and a high speed serial/asynchronous port (NS16550A compatible).

11. See Appendix E for details on Serial I/O options and configuration limitations.

12. xSeries 330 has a single integrated system management port and a single RS485 port.

13. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi

14.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English

31=South Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

15.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English,

45=South Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

44

Updated

17/10/00

45

Updated

17/10/00 xSeries 330 Power, Monitors, Accessories

Part Number

14RIxxx

10

30RIxxx

10

37L6862

94G7448

06P4792

T3347xx

9

31H2Nxx

9

T32N3xx

9

T274Axx

9

11AG1xx

9

APC Smart-UPS 1400RMB

3

APC Smart-UPS 3000RMB

3

APC Smart-UPS 5000RMB

4

Rack Power Cable Type C12 (3.7m)

8

Cable Chain Technology Cable Kit

5

Description

Power

1,8

Uninterruptible Power Supply (UPS)

2

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

6

6

6

G78 Color Monitor 17” (406.4mm, 16.0” Viewable Image Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable Image Size), stealth black

7

1. The xSeries 330 includes a worldwide, voltage sensing 200 W power supply and a standard country power cord.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. The xSeries 330 uses an SVGA controller (S-3 Savage4 chipset) with 8Mb of video memory. A Cable Chain Technology Cable Kit P/N 06P4792 is required for the attachment of console devices to one or multiple chained xSeries 330s. The kit contains a 2M (6.5 feet) KVM breakout cable for attachment to a keyboard. mouse and monitor, as well as a 2 M (6.5 feet) KVM chaining cable for connecting two xSeries 330s together when the standard 245 mm (9.6 inches) KVM chaining cable is not long enough, A maximum of 42 xSeries 330s are supported in a single chain. No more than one kit may be used.

6. Installation within a rack requires optional Monitor Compartment P/N94G7444.

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

8. Rack Power Cable P/N 94G7448 must be ordered for power connection of a rack model to a high voltage UPS or PDU.

9. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

10. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United

Kingdom, EUR=Europe

Part Number Description

Rack and NetBAY

1,2,10

930842P

930842X

9306900

06P6010

9306910

Netfinity Enterprise Rack

4

Netfinity Enterprise Expansion Cabinet

4

Netfinity Rack

2, 5

Netfinity Rack Front Door Kit

3

Netfinity Rack (includes perforated front door)

5

Netfinity Rack Extension Kit

Netfinity NetBAY22

4, 5

36L9703

9306200

36L9702

36L9701

37L6888

94G7448

NetBAY22 Rack Extension Kit

Netfinity NetBAY3E

4, 6

Netfinity Flat Panel Monitor Rack Mount Kit II

Rack Power Cable Type C12 (3.7m)

10

Keyboard and Mouse

7

06P4792

28L36xx

11

28L36xx

12

Cable Chain Technology Cable Kit

7

Space Saver II Keyboard

8

Preferred Keyboard (stealth black)

9

28L3675 Sleek 2-button Stealth Black Mouse

1. xSeries 330 is housed in a 19” rack mountable drawer and requires one of the racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported devices. To provide adequate cooling, Blank Filler Panel Kit P/N 94G6670 should be placed on the front of any unused rack space. If non-IBM racks are to be used, assure that both the front and rear doors offer a minimum of 48% open area uniformely distributed and in line with installed servers. A clearance of 51 to 64-mm (2 to 2-1/2 inches) must be maintained between the front door and the system unit’s front bezel. The rear door must maintain the same or greater clearance. Clearance between the EIA mounting rails and rack side covers must be less than 13-mm (1/2 inch) to prevent air re-circulation from back to front. Non-rack or NetBAY3E installations are not supported.

2. To enable proper cooling, optional Netfinity Rack Front Door Kit P/N 06P6010 must be installed or the front door must be removed. See also Rack P/N 9306910.

3. Provides a perforated front door replacement for the standard glass door of a Netfinity Rack P/N 9306900.

4. To enable proper cooling, the front door (bezel for NetBAY3E) must be removed.

5. Although not required, the use of an appropriate Extension Kit is recommended

6. Up to three xSeries 330s are supported for installation in a NetBAY3E. and up to three NetBAY3Es are supported while installed beneath a Netfinity 8500R. An 8500R must be installed on top of the NetBAY3E.

7. A Cable Chain Technology Cable Kit P/N 06P4792 is required for the attachment of console devices to one or multiple chained xSeries 330s. The kit contains a 2M (6.5 feet) KVM breakout cable for attachment to a keyboard. mouse and monitor, as well as a 2 M (6.5 feet) KVM chaining cable for connecting two xSeries 330s together when the standard 245 mm (9.6 inches) KVM chaining cable is not long enough, A maximum of 42 xSeries 330s are supported in a single chain. No more than one kit may be used.

8. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

9. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

10. The xSeries 330 ships with a standard country power cord. For connection to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

11 . Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland,

19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

12. Where ‘ xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

xSeries 330 Tape Options

Part

Number

Description Bays

Supported

SCSI

Interface

(bit)

Form

Factor

Termination

Included

68/50-pin

Converter Incl.

Ext. Tape

Enclosures

09N4041 12/24 GB DDS/4 4-mm Internal SCSI Tape Drive

09N4042 10/20GB NS Internal SCSI Tape Drive

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

09N4040 20/40 GB DLT Internal SCSI Tape Drive

00N7990 40/80 GB DLT Internal SCSI Tape Drive

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

N/A

1

N/A

1

N/A

1

N/A

1

N/A

1

N/A

1

8

8

16 Ultra2 LVD

8

16 Ultra2 LVD

16 Ultra2 LVD

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

89 mm

(3.5”) SL or

133 mm

(5.25”) HH

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

133 mm

(5.25”) FH

133 mm

(5.25”) FH

133 mm

(5.25”) FH

Y

Y

Y

N

N

N

Y

Y

N/A

Y

N/A

N/A

03K8756

03K8756

03K8756

2

03K8756

03K8756

2

03K8756

2

Tape Autoloaders

00N7992 120/240GB DDS/4 Tape Autoloader N/A

1

16 Ultra2 LVD

133 mm

(5.25”) FH

N N/A 03K8756

2

00N79xx

7

External Tape Libraries

3

DLT Tape Library

External Tape Enclosures

03K8756 NetMEDIA Storage Expansion Unit EL

4

10L7113 NetMEDIA Systems Management Adapter

5

-

-

-

16

16

16 LVD

Rack

Rack

-

Y

Y

N

N/A

N

N

-

-

03K8756

Associated Options

10K2340 Media Bay Tray and LVD Cable Kit

2,6

16 LVD Int.

Y N -

1. xSeries 330 does not support internal tape drives and does not include an external SCSI connector. An external tape or internal tape with a tape enclosure, supported SCSI adapter and appropriate cable must be selected. All tape drives and enclosures are supported by PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which has an external 0.8-mm VHDCI connector. Select tape drive, enclosure and supported adapter then use Appendix D: Cables-Storage Units-Controllers to select an appropriate external cable.

2.LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL P/N 03K8756 requires replacement of the standard single-ended internal cables with one or more (depending on configuration) cables from Media Bay Tray and LVD Cable Kit P/N 10K2340 which contains a single two-drop mult-mode terminated cable. If the standard cables are used for attachment to LVD devices, single-ended SCSI rules and bus speeds apply.

3. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

4. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

5. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

6. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

7. Where ‘xx’ represents a country specific power cord code: Rack versions - 81=EU1, 82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat xSeries 330 Sample Configurations

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

46

Updated

17/10/00

47

Updated

17/10/00

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

1

Part Number Description Quantity

K441Yxx

37L7205

06P4792

31H2Nxx

28L36xx

14RIxxx xSeries 330 (Pentium III 933/256 MB/0 GB)

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

2

Cable Chain Technology Cable Kit

3

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

Space Saver II Keyboard

APC Smart-UPS 1400RMB

1

2

1

1

1

1

1. This example shows a 19” rackable configuration. The rack components are not included.

2. For a total of 36.4 GB of internal storage.

3. A single Cable Chain Technology Cable Kit P/N 06P4792 is required for attachment of one or multiple (up to 42) chained xSeries 330s to a single monitor, mouse and keyboard.

An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (firewall). In the case of an

Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.

With this is mind, the xSeries 330 was selected to provide an affordable price point for the growing Internet server market with two-way Pentium III processing, 256 MB of system memory (expandable to 4GB), and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods are used you can add the appropriate adapter.

File and Print Server

1

Part Number Description Quantity

K451Yxx

33L3142

37L7206

06P4792 xSeries 330 (Pentium III 1 GHz/256 MB/0 GB) xSeries 128 MB 133 MHz ECC SDRAM RDIMM

2

36.4 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

3

Cable Chain Technology Cable Kit

4

2

1

1

1

31H2Nxx

28L36xx

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

Space Saver II Keyboard

1

1

14RIxxx APC Smart-UPS 1400RMB 1

1. This example shows a 19” rackable configuration. The rack components are not included.

2. For a total of 384 MB of system memory.

2. For a total of 72.8 GB of internal storage.

4. A single Cable Chain Technology Cable Kit (P/N 06P4792) is required for attachment of one or multiple (up to 42) chained xSeries 330s to a single monitor, mouse and keyboard.

A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing environment, but doesn’t require the high-end performance and fault-tolerance properties of larger servers.

The sample configuration above consists of an xSeries 330 with 384MB of memory and 72.8 GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.

This configuration also includes a UPS to keep the system protected during power surges and outages.

Application Server

1

Part Number

K431Yxx

10K3810

33L3144

37L7205

06P4792

Description xSeries 330 (Pentium III 800/256 MB/0 GB)

800 MHz Upgrade with 133MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor xSeries 256 MB 133 MHz ECC SDRAM RDIMM

2

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

3

Cable Chain Technology Cable Kit

4

Quantity

1

31H2Nxx

28L36xx

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

Space Saver II Keyboard

14RIxxx APC Smart-UPS 1400RMB

1. This example shows a 19” rackable configuration. The rack components are not included.

2. For a total of 512 MB of system memory.

2. For a total of 36.4 GB of internal storage.

4. A single Cable Chain Technology Cable Kit P/N 06P4792 is required for attachment of one or multiple (up to 42) chained xSeries 330s to a single monitor, mouse and keyboard.

1

1

1

2

1

1

1

An application server differs from a file and print server in that it has a higher workload, in providing application serving requirements for users. With this in mind, the xSeries 330 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 512 MB of system memory (expandable to 4 GB), and availability features such as RAID-protected internal storage and power protection with an APC Smart-UPS.

IBM xSeries 340 and Netfinity 4500R

xSeries 340 / Netfinity 4500R At-A-Glance

xSeries 340

K66RYxx

1

1 GHz 1/2 256

128MB

(R)/4GB

Rack(3U) 1/2 P, H, F

O - Power

3

S - Fans

Y 10/100 D,U160 4/2

4

0/218.4

GB

5

24X-

10X

8/6

5

5/5

Netfinity 5600

62RYMxx

61RYMxx

63RYTxx

64RYTxx

65RYTxx

1

1

1

1

1

24/10/00

-

-

-

-

667

733

800

866

933

1/2

1/2

1/2

1/2

1/2

256

256

256

256

256

128MB

(R)/4GB

128MB

(R)/4GB

128MB

(R)/4GB

128MB

(R)/4GB

128MB

(R)/4GB

Rack (3U)

Rack(3U)

Rack(3U)

Rack(3U)

Rack(3U)

1/2

1/2

1/2

1/2

1/2

P, H, F

P, H, F

P, H, F

P, H, F

P, H, F

O - Power

3

S- Fans

O - Power

3

S - Fans

O - Power

3

S - Fans

O - Power

3

S - Fans

O - Power

3

S - Fans

Y

Y

Y

Y

Y

10/100

10/100

10/100

10/100

10/100

D,U160

D,U160

D,U160

D,U160

D,U160

4/2

4/2

4/2

4/2

4/2

4

4

4

4

4

0/218.4

GB

0/218.4

GB

GB

GB

5

5

0/218.4

5

0/218.4

5

0/218.4

GB

5

24X-

10X

24X-

10X

24X-

10X

24X-

10X

24X-

10X

8/6

8/6

8/6

8/6

8/6

5

5

5

5

5

5/5

5/5

5/5

5/5

5/5

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See Power, Monitors, Accessories section for supported IBM racks.

2. Intel Pentium III processor with 133 MHz front-side bus.

3. Power supply redundancy requires installation of optional 270 W Hot-Swap Redundant Power Supply P/N 37L6879.

4. xSeries 340 / Netfinity 4500R includes two available removable media bays that can be converted to three slim-line (SL) hot-swap bays with the addition of optional 3-Pack Hot-Swap DASD Upgrade (P/

N 33L5050), thus doubling internal hard disk drive storage capacity.

5. Assumes installation of optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050 which converts the two available removable media bays into three slim-line (SL) hot-swap bays.

6. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

7. Not available from IBM after this date. Business Partner inventory may be available.

xSeries 340 / Netfinity 4500R Processor Upgrades

Part Number Processor Upgrades with 256 KB Cache

(Full Speed)

SMP Support

1

Processor Speed Upgrade

2

00N7949

00N7943

10K2338

Netfinity 667 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 733 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 800 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

Netfinity 866 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

2RY

1RY

3RY

-

2RY

1RY/2RY

19K4630

19K4631

19K4640

Netfinity 933 MHz 133 FSB/256 KB Upgrade with Pentium III Processor

1 GHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache

Pentium III Processor

4RY

5RY

6RY

All 1...3RY

All 1...4RY

All 1...5RY

1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

48

Updated

17/10/00

49

Updated

17/10/00

RDIMM Socket 4

RDIMM Socket 3

RDIMM Socket 2

RDIMM Socket 1 xSeries 340 / Netfinity 4500R Memory Configurator

Total Memory

1

128 MB

(1 x 128)

Models

256 MB

384 MB

128 MB

(33L3123)

1

2 or

Std. (R)DIMM

Recommended order of installation:

Slot 1-2-3-4

Part Number Memory Description

1

33L3123

33L3125

128 MB, 133 MHz SDRAM ECC RDIMM II

256 MB, 133 MHz SDRAM ECC RDIMM II

33L3127

33L3129

512 MB, 133 MHz SDRAM ECC RDIMM II

1 GB, 133 MHz SDRAM ECC RDIMM II

1. The recommended order of installation is in sequence from Socket 1 to Socket 4.

Memory size is not a factor.

512 MB 3

Quantity of RDIMMs Added

256 MB

(33L3125)

-

1

-

512 MB

(33L3127)

-

-

-

1 GB

(33L3129)

-

-

-

640 MB

896 MB

1024 MB

1152 MB

1664 MB

2048 MB

-

-

-

-

-

-

2 or

3

4

2

-

-

-

1

-

-

2 or

3

4

2

-

-

-

1

-

-

2176MB

3200 MB

4096 MB (max)

-

-

-

-

-

-

-

-

-

2

3

4

2

This table does not represent all possible memory configurations. Memory modules may vary in price per MB.

Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. Requires removal of standard memory.

xSeries 340 / Netfinity 4500R Internal Hard Disk Drive and External Storage Coinfigurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

18.2 GB

(P/N 37L7202)

36.4 GB

(P/N 37L7203)

9.1 GB

10,000RPM Hard Disk Drives (HDDs)

(P/N 37L7204)

18.2 GB

(P/N 37L7205)

36.4 GB

(P/N 37L7206)

0 GB

9.1 GB 1

Standard on Base Models

1

Standard on Base Models

-

18.2 GB

27.3 GB

36.4 GB

45.5 GB

54.6 GB

72.8 GB

91 GB

2

3

4

2

5

6

-

-

2

2

1

-

2

-

3

4

2

5

2

6

2

-

-

-

1

-

-

2

-

2

3

4

2

5

2

6

2

-

-

1

-

2

-

3

4

2

5

2

6

2

-

-

-

1

-

-

2

-

109.2 GB

145.6GB

-

-

3

4

2

5

2

-

-

3

4

2

5

2

182 GB

218.4 GB

(max.)

-

-

-

6

2

-

-

-

6

2

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

2. Requires Netfinity 3-Pack Ultra 160 Hot-Swap Expansion Kit P/N 33L5050.

Bay

-

-

1...3

A, B

4...6

3

Form Factor

89 mm

(3.5”)

133 mm (5.25”)

HS

133 mm

(5.25”)

HS

RM A

RM B

HS 4

HS 5

HS 6

Height

Diskette

CD-ROM

Removable Media

(RM)

-

-

SL

1

HH

2

SL

1

Hot-Swap

(HS)

1

Front

Access

Yes

Yes

Yes

Yes

Yes

2 3

Usage

Diskette

IDE CD-

ROM

Open

Open

Open

1. Half-High devices are NOT supported.

2 Two half-high (HH) bays can be combined to support a single full-high (FH) device. By installing Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit (P/N

33L5050), bays A and B are transformed into three SL hot-swap

bays 4...6.

3. To enable bays 4...6, optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit

(P/N 33L5050) is required.

Part

Number

Description RPM Height Bays

Supported

2

Max.

Qty.

37L7201

37L7202

37L7203

37L7204

37L7205

37L7206

19K0655

19K0656

Ultra160 Hard Disk Drives

(HDD)

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap SL

HDD

36.4 GB Ultra160 SCSI Hot-Swap SL

HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

9.1 GB 15K-rpm Ultra160 SCSI Hot-

Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

7200

7200

7200

10,000

10,000

10,000

15000

15000

SL

SL

SL

SL

SL

SL

SL

SL

1...6

1...6

1...6

1...6

1...6

1...6

1...6

1...6

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

33L5050

Associated Options

Netfinity 3-Pack Ultra160 Hot-Swap

Expansion Kit

2

3 x SL 4...6

-

External Storage Expansion

Units

3

Form Factor

00N6xxx

37L0xxx

8

9

Netfinity EXP200 Storage Expansion

Unit

4, 7

Netfinity EXP200 350 W Redundant

Power Supply

7

EXP300 Storage Expansion Unit

5, 7

19K11xx

10

00N71xx

11

FAStT EXP500 Storage Expansion

Unit

6, 7

94G7448 Rack Power Cable Type C12 (3.7m)

7

Rack (3U)

-

Rack (3U)

Rack (3U)

-

1. Netfinity 4500R ships with Bays 1...3 enabled. To enable installation of greater than three HDDS requires Netfinity 3-

Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050.

2. Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050 includes a hot-swap backplane and associated components for two cabling options. The backplane may be cabled directly to the second integrated SCSI channel or be supported by the same SCSI channel as the standard backplane through the use of an included repeater card.

3. Select an optional SCSI controller and then refer to Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

4. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and single hot-swap 350W power supply. Optional hot-swap

Netfinity EXP200 350W Redundant Power Supply (P/N 37L0xxx) provides redundancy.

5. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies.

6. FAStT EXP500 Storage Expansion Unit (P/N 00N71xx) includes dual hot-swap 350W power supplies.

7. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

8. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

9. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/

English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

10.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

11. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

xSeries 340 / Netfinity 4500R Internal SCSI Cabling

The xSeries 340 and Netfinity 4500R contain a DASD backplane supporting three hot-swap, SCA-2 compliant drive bays. The backplane is connected to one of the internal connectors of the integrated Ultra160 SCSI controller through a 16-bit LVD SCSI cable. A single-drop 16-bit SCSI cable is included with the server for attachment from the second internal Ultra160 connector to a removable media bay device. If an LVD attachment is required or more than one media bay device is required, a terminated two-drop 16-bit LVD

SCSI cable available in the Netfinity Media Bay Conversion Kit P/N 10K2340 must be ordered. No external SCSI port is included.

If optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050 is installed in the removable media bays, four cabling options are possible. Included with this option is a 16-bit LVD SCSI cable, identical to the one used for attachment of the standard hot-swap backplane, which can be used to attach the optional 3-Pack Ultra160 Hot-Swap backplane directly to the second onboard SCSI connector or that of an optional RAID adapter. Alternatively, a repeater card and cable are included which may be used to link the standard hotswap backplane and optional hot-swap backplane together while utilising the standard SCSI cable for attachment of the repeater card to one of the onboard SCSI connectors or that of an optional RAID adapter.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

50

Updated

17/10/00

51

Updated

17/10/00 xSeries 340 / Netfinity 4500R I/O Options

Part

Number

Description

19K0564

37L6086

37L6091

37L6080

37L6889

19K4646

02K3454

00N6881

19K11xx

21

19K11xx

22

19K1121

34L1501

34L0301

34L0701

Storage Controllers

1

Netfinity ServeRAID-3L Ultra2 SCSI Adapter II

2

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

3

ServeRAID-4L Ultra160 SCSI Controller

4

ServeRAID-4M Ultra160 SCSI Controller

5

ServeRAID-4H Ultra160 SCSI Controller

6

PCI Wide Ultra160 SCSI Adapter

16

PCI Fast/Wide Ultra SCSI Adapter

7

Fibre Storage Controllers and Options

8

Netfinity FAStT Host Adapter

FAStT200 Storage Server

FAStT200 HA Storage Server

FAStT200 Redundant RAID Controller

Networking

9

Ethernet

Netfinity 10/100 Ethernet PCI Adapter 2

Netfinity Gigabit Ethernet SX Adapter

Token Ring

Token-Ring 16/4 PCIAdapter 2 with Wake on LAN

17

Communications

10

Adapter

Length

Full

Full

Full

Full

Full

Half

Half

Half

-

-

-

Half

Half

Half

PCI Support

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32/64-bit

-

-

-

32-bit

32/64-bit

32-bit

Slots

Supported

1...5

1...5

1...5

1...5

1...5

1...5

1...5

1...5

-

-

-

1...5

1...5

1...5

Exterior Connector Access

36L96xx

20

03K9309

36L9654

Systems Management

11

Netfinity Advanced System Management PCI Adapter

12

Netfinity Advanced System Management Interconnect Cable

Kit

14

Netfinity Adv6nced System Management Token-Ring

Connection

15

Full

-

-

32-bit

-

-

1...5

13

-

-

10L7368

Host Attach

Netfinity ESCON Adapter

18

Full 32-bit 1...5

19

1. xSeries 340 / Netfinity 4500R include a dual-port, dual-channel Ultra160 SCSI controller for internal use only. No standard external port is available. See “Internal SCSI Cabling” for cabling alternatives. Due to Netfinity 4500R’s low profile, some adapters with connectors on the top edge may not have sufficient clearance to attach a cable. Cabling interferences are identified in the footnotes.

2. Netfinity ServeRAID-3L Ultra2 SCSI Adapter II (P/N 19K0564) provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

3. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal connector is not accessible due to a cabling interference. Includes 32 MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

4. ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection. External connector is 0.8-mm VHDCI.

5. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two external

0.8-mm VHDCI Ultra160 connectors.

6. ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache. The internal connectors are not accessible due to cabling interference. Four external Ultra160 0.8-mm VHDCI connectors are available.

7. PCI Fast/Wide Ultra SCSI Adapter provides one external 68-pin high density connector. The internal connectors are not accessible due to a cabling interference.

8. See Fibre Array Solutions section for additional configuration information.

9. xSeries 340 / Netfinity 4500R include a full-duplex, 10/100 Mbps Ethernet PCI controller.

10. xSeries 340 / Netfinity 4500R include two USB ports, two serial and one parallel port.

11. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into xSeries 340 / Netfinity 4500R works with Netfinity Director to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 36L96xx) and Netfinity Advanced System Management Interconnect Cable Kit (P/N

03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.

12. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter, which requires a separate power source. Provides an integrated

10/100 Ethernet port and a PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654).

13. A maximum quantity of one is supported.

14. Required for all xSeries and Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 1xX...4xX are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 36L96xx) includes the contents of this option.Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more

than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.

15 Contains an IBM Turbo 16/4 Token-Ring PCI card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter (P/N 36L96xx), and a PC Card to 9-pin

D-Shell cable which is routed to an available adapter slot opening (reduces available slots by one). The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and

Netfinity Advanced System Management Token-Ring Connection cannot be connected or used together.

16. PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm VHDCI connector. Only one of the two connectors may be utilised.

17. The Wake on LAN function of this option is not supported by this server.

18. Provides an ESCON MIC and a DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.

19. A maximum of two ESCON adapters (installed in non-adjacent slots) are supported in a single server.

20. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi Arabia.

21.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English

31=South Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

22.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English,

45=South Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

xSeries 340 / Netfinity 4500R Power, Monitors, Accessories

Part Number

37L6879

94G7448

14RIxxx

10

30RIxxx

10

37L6862

T3347xx

9

31H2Nxx

9

T32N3xx

9

T274Axx

9

11AG1xx

9

Description

Power

1,8

270 W Hot-Swap Redundant Power Supply

8

Rack Power Cable Type C12 (3.7m)

8

Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 1400RMB

3

APC Smart-UPS 3000RMB

3

APC Smart-UPS 5000RMB

4

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

G78 Color Monitor 17” (406.4-mm, 16” Viewable Image Size), stealth black

6

6

6

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

7

1. xSeries 340 / Netfinity 4500R include a single 270 W, hot-swap power supply and a single standard country power cord. Power supply redundancy can be achieved with the addition of optional 270 W Hot-Swap Redundant Supply P/N 37L6879.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. xSeries 340 / Netfinity 4500R use an SVGA controller (S3 Savage4 chipset) with 8 MB of video memory.

6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II P/N 37L6888 and Netfinity Rack

Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

8. Rack Power Cable P/N 94G7448 (type C12 - one for each power supply), must be ordered for power connection of a rack model to a high voltage UPS or PDU.

9. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa,

CH=Switzerland, UK=UK, EU=Europe.

10. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia,

SAF=South Africa, SWS=Switzerland, UKM=United Kingdom, EUR=Europe.

Part Number

930842P

Description

Rack and NetBAY

1,8

Netfinity Enterprise Rack

930842X

9306900

9306910

9306200

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (includes perforated front door)

Netfinity NetBAY22

37L6888

94G7448

28L36xx

6

28L36xx

7

Netfinity Flat Panel Monitor Rack Mount Kit II

Rack Power Cable Type C12 (3.7m)

8

Keyboard and Mouse

2

Space Saver II Keyboard

3, 5

Preferred Keyboard (stealth black)

4

28L3675 Sleek 2-Button Stealth Black Mouse

1. xSeries 340 / Netfinity 4500R are housed in a 19” rack mountable drawer and requires one of the racks listed here. See IBM

Netfinity Rack Cabinet and Options section for IBM rack supported devices.

2. xSeries 340 / Netfinity 4500R ship without a keyboard or mouse.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

5. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

6 . Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English,

44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium,

19K3836=Russia, 19K3837=Poland.

7. Where ‘ xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English, 31=Danish, 33=Norwegian,

34=Swedish/Finnish, 35=Swiss, 36=Dutch.

8. The xSeries 340 / Netfinity 4500R ships with a standard country power cord. For connection to a high voltage UPS or PDU, a

Rack Power Cable P/N 94G7448 (type C12), must be ordered.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

52

Updated

17/10/00

53

Updated

17/10/00 xSeries 340 / Netfinity 4500R Tape Options

Part

Number

Description Bays

Supported

SCSI

Interface

(bit)

Form

Factor

Termination

Included

68/50-pin

Converter Incl.

Ext. Tape

Enclosures

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

2

01K1325 20/40 GB 8-mm Internal SCSI Tape Drive

09N4040 20/40 GB DLT Internal SCSI Tape Drive

00N7990 40/80 GB DLT Internal SCSI Tape Drive

2

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

2

A, B

A, B

A/B

A/B

A, B

16 Ultra2 LVD

16

8

16 Ultra2 LVD

16 Ultra2 LVD

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

133 mm

(5.25”) HH

133 mm

(5.25”) FH

133 mm

(5.25”) FH

133 mm

(5.25”) HH

Y

N

3

N

3

N

3

N

3

N/A

N/A

Y

N/A

N/A

03K8756

1

03K8756

03K8756

03K8756

1

03K8756

1

Tape Autoloaders

00N7992 120/240GB DDS/4 Tape Autoloader

2

A/B 16 Ultra2 LVD

133 mm

(5.25”) FH

N

3

N/A 03K8756

1

00N79xx

8

External Tape Libraries

4

DLT Tape Library

External Tape Enclosures

03K8756 NetMEDIA Storage Expansion Unit EL

5

10L7113 NetMEDIA Systems Management Adapter

6

-

-

-

16

16

16 LVD

Rack

Rack

-

Y

Y

N

N/A

N

N

-

-

03K8756

Associated Options

10K2340 Media Bay Tray and LVD Cable Kit

1,2,7

16 LVD Int.

Y N -

Note: xSeries 340 / 4500R includes a single drop, 16-bit, single-ended, non-terminated SCSI cable for attachment of a device in Bay A or B to the second integrated Ultra160 SCSI channel or supported adapter. No external SCSI port is available. All tape drives and enclosures are supported by PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) which has an external 0.8-mm VHDCI connector.

1.LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL (P/N 03K8756) requires replacement of the standard single-ended internal cables with one or more (depending on configuration) cables from Media Bay Tray and LVD Cable Kit (P/N 10K2340) which contains a single two-drop multi-mode terminated cable. If the standard cables are used for attachment to LVD devices, single-ended SCSI rules and bus speeds apply.

2. LVD support for LVD devices requires installation of the 16-bit multi-mode terminated, two-drop, LVD SCSI cable included with optional Media Bay Tray and LVD Cable Kit (P/N 10K2340)

3. Termination requires installation of the multi-mode terminated, two-drop, LVD SCSI cable included with optional Media Bay Tray and LVD Cable Kit (P/N 10K2340)

4. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

5. NetMEDIA Storage Expansion Unit EL (P/N 03K8756) is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

6. NetMEDIA Systems Management Adapter (P/N 10L7113) may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

7. Media Bay Tray and LVD Cable Kit (P/N 10K2340) includes an internal two-drop multi-mode terminated LVD SCSI cable.

8. Where ‘xx’ represents a country specific power cord code: Rack versions - 81=EU1, 82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

xSeries 340 / Netfinity 4500R Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

Part Number Description

65RYTxx

33L3123

37L6086

37L7201

01K1325

10K2340

Netfinity 4500R 340Pentium III 933 MHz/256 KB L2, 128 MB ECC, OPEN, 24X, PCI (Rack 3U)

128 MB SDRAM ECC RDIMM II

1

Netfinity ServeRAID 3HB Ultra2 SCSI Adapter

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

2

20/40 GB 8-mm Internal SCSI Tape Drive

Media Bay Tray and LVD Cable Kit

31H2Nxx

14RIxxx

37L6879

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 1400RMB

270 W Hot-Swap Redundant Power Supply

Industry Standard 19” Rack, EIA-310D, min. depth of 28” (711 mm)

9306200

28L36xx

Netfinity NetBAY22

Space Saver II Keyboard

94G6670 Blank Filler Kit

1. For a total of 256 MB of system memory.

2. For a total of 27.3 GB of RAID protected hot-swap, hot-spare internal storage.

Quantity

1

1

1

4

1

1

1

1

1

1

1

2

An internet server is a server that handles all requests from the Internet (intranet or extranet). Usually this type of server has the same characteristics as a file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (Firewall). In the case of an internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does. With this in mind the xSeries 340 was selected to provide an affordable price point for the growing internet server market, 256 MB of system memory (expandable to 4 GB), and availability features such as RAID protected internal hot-swap storage and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the internet. Usually fast Ethernet routers are used, but if other methods are used, you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

Application Server

Part Number Description

K66RYxx

19K4630

33L3125

37L6086

37L7202

01K1325 xSeries 340 Pentium III 1 GHz/256 KB L2, 128 MB ECC, OPEN, 24X, PCI (Rack 3U) xSeries1 GHz Upgrade with 133 FSB and 256 KB Advanced Transfer Cache Pentium III Processor

256 MB 133 MHz SDRAM ECC RDIMM II

Netfinity ServeRAID 3HB Ultra2 SCSI Adapter

18.2 GB Ultra160 SCSI Hot-Swap SL HDD

2

20/40 GB 8-mm Internal SCSI Tape Drive

10K2340

31H2Nxx

37L6879

14RIxxx

Media Bay Tray and LVD Cable Kit

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

Netfinity 270 W Hot-Swap Redundant Power Supply

9306200

28L36xx

94G6670

APC Smart-UPS 1400RMB

Industry Standard 19” Rack, EIA-310D, min. depth of 28” (711 mm)

Netfinity NetBAY22

Space Saver II Keyboard

Blank Filler Kit

1. For a total of 384 MB of system memory.

2. For a total of 54.6 GB of usable RAID 5 storage.

Quantity

1

1

1

1

3

1

1

1

1

1

1

1

2

An application server is designed to handle a high workload while providing application serving requirements for users. With this in mind, the xSeries 340 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 384 MB of system memory (expandable to 4GB),and availability features such as batterybacked cache, RAID protected internal hot-swap storage and power protection with an APC Smart-UPS.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

54

Updated

17/10/00

55

Updated

17/10/00

IBM Netfinity 1000 Value Model Configurator

751YExx 24/10/00 650

1

1/1 256 64/768 Tower 1/1 10/100

761YExx 700

1

1/1 256 64/768 Tower 1/1 10/100

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance

1. Intel Pentium III processor.

2. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

3. Not available from IBM after this date. Business Partner inventory may be available.

IDE

IDE

4/2

4/2

10.1/

30.3GB

10.1/

30.3GB

40X-17X

40X-17X

6/3

6/3

6/6

6/6

Netfinity 1000 Value Model Processor Upgrades

Processor Upgrade

Part

Numbers

Upgrade

Support

1

Netfinity 700MHz/256KB Pentium III Processor Upgrade 10K2165 51Y

1. Requires removal of the standard processor. A maximum of one processor may be installed. Upgrades may require a BIOS update. To obtain the latest FLASH BIOS, access URL http:// www.pc.ibm.com/pc/us, select PERSONAL SUPPORT then select IBM SERVER SUPPORT. Choose a machine type then select Downloadable files and choose the category labled “BIOS”.

DIMM Socket

DIMM Socket

DIMM Socket

DIMM Description

Netfinity 1000 Value Model Memory Configurator

Part Numbers

64MB 100MHz ECC SDRAM DIMM 01K1130

128MB 100MHz ECC SDRAM DIMM

256MB 100MHz ECC SDRAM RDIMM

1

01K1131

01K1132

1. P/N 01K1132 is a registered DIMM and is not compatible with P/N 01K1130 or P/N 01K1131. Installation of this RDIMM requires replacement of any standard DIMM.

Total

Memory

64MB

128MB

192MB

256MB

All Models

64MB DIMM Standard

1 x 01K1130

1 x 01K1131

1 x 01K1131, 1 x 01K1130

320MB

384MB

512MB

2 x 01K1131

3 x 01K1131

1

2 x 01K1132

1

3 x 01K1132

1

768MB (max)

This table does not represent all possible memory configurations.

1. Replace standard DIMM.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

56

Updated

17/10/00

Netfinity 1000 Value Model Internal Hard Disk Drive Configurator

CD ROM

Bay 2

Bay 3

Diskette

Total Internal Disk

Storage

1

All Models

10.1GB

20.2GB

Standard

1 x 33L4958

30.3GB

2 x 33L4958

1. Total Internal Storage listed is within + 0.2GB unless otherwise noted.

Bay 5

Bay 6

Bays Form

Factor

1

2

3

4

5

6

133 mm

(5.25”)

133 mm

(5.25”) 1

89 mm

(3.5”)

89 mm

(3.5”)

89 mm

(3.5”)

89 mm

(3.5”)

Height Front

Access

HH

HH

SL

SL

SL

2

SL

2 yes yes yes yes no no

Usage

32x IDE CD-ROM open open diskette open open

1. A 3.5” conversion kit is standard in Bay 2 for installation of 3.5” devices.

2. Two slim-line bays can be combined to support a single half-high (HH) device.

Part

Numbers

33L4958

Description

10.1GB 7200rpm EIDE HDD

1

RPM

7200

Height

SL

1. This Hard Disk Drive is the only one supported in the Netfinity 1000 IDE Models.

Bays

Supported

2,3,5,6

Max.

Qty.

3

Internal Cabling

The Netfinity 1000 Value models have an onboard IDE Storage Controller that provides support for up to four internal IDE devices. A two-drop IDE cable is attached to one of the

IDE controller connectors and is used for the standard IDE CD-ROM drive and 10.1GB 7200rpm EIDE Hard Disk Drive. A second two-drop IDE cable is shipped with the server to be used for installing a second and third 10.1GB EIDE HDD as desired. This cable attaches to the second connector of the IDE controller.

Netfinity 1000 Value Model I/O Options

Part

Number

Description

02K3454

34L1501

34L0701

34L5201

37L14xx

Storage Controllers

1

PCI Fast/Wide Ultra SCSI Adapter

2

Networking

3

Ethernet

Netfinity 10/100 Ethernet PCI Adapter 2

Token Ring

Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

4

High speed 100/16/4 Token Ring PCI Management Adapter

Communications

Serial I/O SST8, 16 and 128 port adapters

5

Systems Management

6

Adapter

Length

Half

Half

Half

Half

Half

PCI

Support

32-bit

32-bit

32-bit

32-bit

32-bit

Slots

Supported

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1. The Netfinity 1000 IDE models ship with integrated IDE controller and cable for support of up to 3 hard disk drives. Optional SCSI support is limited to Tape Drives only.

No SCSI hard disk drives are supported.

2. Supports attachment of internal tape drive only. Includes 16-bit SCSI cable.

3.The Netfinity 1000 IDE models have an integrated 10/100 PCI Ethernet Controller.

4.The Wake on LAN function of this option is not supported by Netfinity Servers.

5. See Appendix E for details on Serial I/O options and configuration limitations.

6. The Netfinity 1000 IDE models provide the following integrated system management features - Vital Product Data (VPD) plus thermal, voltage, and fan sensors.

57

Updated

17/10/00

I/

Netfinity 1000 Value Model Power, Monitors, Accessories

Part Number

SUP072Y

SUP102Y

Description

Power

1

Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 700

APC Smart-UPS 1000

Monitors

T3347xx

3

31H2Nxx

3

T32N3xx

3

T274Axx

3

11AG1xx

3

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

1. The Netfinity 1000 model 42Y includes a 330 W voltage sensing power supply.

2. For runtimes and UPS attributes, see Appendix C: UPS Runtime Estimate.

3. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa,

CH=Switzerland, UK=UK, EU=Europe.

Netfinity 1000 Value Model Tape Option

Part Number

09N4042

Description

IBM 10/20GB NS Internal SCSI Tape Drive

1

Bays

Supported

SCSI Interface

(bit)

2, 3 8

Form

Factor

89 mm (3.5”)

SL or 133 mm

(5.25”) HH

1. Requires PCI Fast/Wide Ultra SCSI Adapter P/N 02K3454, which includes a SCSI cable.

Termination

Included

Y

68/50-pin

ConverterIncl.

Y

Ext. Tape

Enclosures

N/A

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

58

Updated

17/10/00

Netfinity 1000 Value Model Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Workgroup Internet Server

Part Number Description

761YExx

01K1130

33L4958

02K3454

09N4042

IBM Netfinity 1000 IDE Pentium III 700/256KB L2, 64MB ECC, 10.1GB

64MB 100MHz ECC SDRAM DIMM

1

10.1GB 7200rpm EIDE HDD

PCI Fast/Wide Ultra SCSI Adapter

2

IBM 10/20GB NS Internal SCSI Tape Drive

31H2Nxx

SUP102Y

E54 Color Monitor 15” (13.8” Viewable Image Size), stealth-black

1. For a total of 128MB of system memory.

2. Includes a 16-bit SCSI Cable

APC Smart-UPS 1000

Quantity

1

1

1

1

1

1

1

An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an Internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (Firewall). In the case of an

Internet server, the server itself talks mostly to just one client, the Internet Service Provider(ISP), instead of many clients like a file server does.

With this in mind, the IBM Netfinity 1000 (IDE) was selected to provide an affordable price point for the growing Internet server market with Pentium III processing, 128MB of system memory (expandable to 768MB), integrated 100/10 Ethernet controller, high-performance storage, and power protection with an APC Smart-UPS.

The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

File & Print Server

Part Number Description

761YExx

01K1130

02K3454

09N4042

IBM Netfinity 1000 IDE Pentium III 700/256KB L2, 64MB ECC, 10.1GB

64MB 100MHz ECC SDRAM DIMM

1

PCI Fast/Wide Ultra SCSI Adapter

2

IBM 10/20GB NS Internal SCSI Tape Drive

31H2Nxx

SUP072Y

E54 Color Monitor 15” (13.8” Viewable Image Size), stealth-black

APC Smart-UPS 700

1. For a total of 128MB of system memory.

2. Includes a 16-bit SCSI Cable

Quantity

1

1

1

1

1

1

A small business or departmental server is usually required to perform all typical server functions while servicing up to 50 users in a normal workgroup computing environment, but doesn’t require the high-end performance and fault tolerance properties of larger servers. The sample configuration above consists of an IBM Netfinity 1000 IDE model with 128MB of memory and 10.1GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional internal storage expansion still available. Demanding network traffic is effectively handled by the standard 100Mbps Ethernet connection. This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected from power surges and outages.

59

Updated

17/10/00

IBM Netfinity 3000 Configurator

761UExx

770UExx

771UExx

780UExx

781UExx 24/10/00

790UExx -

791UExx

24/10/00

29/12/00

29/12/00

24/10/00

-

550

3

600

3

600

3

650

4

650

4

700

4

700

4

1/1

1/1

1/1

1/1

1/1

1/1

1/1

512

512

512

256

256

256

256

64/768

64/768

64/768

64/768

128/768

64/768

128/768

Tower

Tower

Tower

Tower

Tower

Tower

Tower

1/1

1/1

1/1

1/1

1/1

1/1

1/1

10/100

10/100

10/100

10/100

10/100

10/100

10/100

U

U

U

U2

U2

U2

U2

4/2

4/2

4/2

4/2

4/2

4/2

4/2

9.1/145.6 GB

0/145.6 GB

9.1/145.6 GB

0/145.6 GB

9.1/145.6 GB

0/145.6 GB

9.1/145.6 GB

2

2

2

2

40X-17X

40X-17X

40X-17X

40X-17X

40X-17X

40X-17X

40X-17X

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance

1. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

2. Standard Hard Disk Drives (HDD) are 7200 RPM. Maximum internal capacities assume replacement of standard hard disk drives with the largest supported IBM hard disk drives.

3. Intel Pentium III processor.

4. Intel Pentium III processor with advanced transfer (full speed) L2 cache.

5. Not available from IBM after this date. Business Partner inventory may be available.

6/3

6/4

6/3

6/3

6/4

6/3

6/4

DIMM Socket

DIMM Socket

DIMM Socket

Netfinity 3000 Processor Upgrades

Processor Upgrades

Part

Numbers

Upgrade

Support

1

Netfinity 600 MHz/512 KB Upgrade with Pentium III Processor 33L5106

All 71xxxxx to

76xxxxx

Netfinity 700 MHz/256 KB Upgrade with Pentium III Processor

2

10K2165 All 8xU

1. Requires removal of the standard processor. A maximum of one processor may be installed. Upgrades may require a BIOS update. To obtain the latest FLASH BIOS, access URL http:// www.pc.ibm.com/europe/netfinity.html, then select SUPPORT. Choose a machine type then select Downloadable files and choose the category labled “BIOS”..

2. Cannot be used to upgrade models 71xxxxx through 77xxxxx.

Netfinity 3000 Memory Configurator

Total

Memory

64MB

128MB

64MB Models

64MB DIMM Standard

1 x 01K1130

128MB Models

-

128MB DIMM Standard

192MB 1 x 01K1131 1 x 01K1130

DIMM Description

64MB 100MHz ECC SDRAM DIMM

128MB 100MHz ECC SDRAM DIMM

256MB 100MHz ECC SDRAM RDIMM

1

Part Numbers

01K1130

01K1131

01K1132

1

256MB 1 x 01K1131, 1 x 01K1130 1 x 01K1131

320MB

384MB

512MB

2 x 01K1131

3 x 01K1131

2

2 x 01K1132

2

3 x 01K1132

2

1 x 01K1131, 1 x 01K1130

2 x 01K1131

2 x 01K1132

2

3 x 01K1132

2

768MB (max)

This table does not represent all possible memory configurations.

1. 256MB RDIMM P/N 01K1132 is a Registered DIMM and is not compatible with P/N 01K1130 or P/N 01K1131.

Installation of this RDIMM requires replacement of any standard DIMM.

2. Replace standard DIMM.

6/5

6/5

6/5

6/5

6/5

6/5

6/5

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

60

Updated

17/10/00

CD-ROM

Bay 2

Bay 3

Diskette

Bay 5

Bay 6

Netfinity 3000 Internal Hard Disk Drive Configurator

Total

Internal

Storage

1

Open Bay Examples

2

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8204)

18.2 GB

(P/N 00N8205)

36.4 GB

(P/N 00N8206)

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

Note: 9.1GB disk is standard in models

7x1UExx

2

3

4

-

-

1

-

2

-

-

-

-

1

-

54.6 GB

72.8 GB

91 GB

-

-

3

4

-

2

109.2 GB

145.6 GB

(max)

-

-

-

-

-

-

-

3

4

This table does not represent all possible hard drive configurations.

1. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

2. Select a total storage row and then select the quantity of HDDs from a column corresponding to the appropriate hard disk drive. When configuring models which include a single 9.1 GB HDD, use the 9.1 GB column and order one less HDD than the table indicates.

Bay Form

Factor

Height Front

Access

Usage

1

2

3

4

133 mm

(5.25”)

133 mm

(5.25”)

1

89 mm

(3.5”)

89mm

(3.5”)

HH

HH

SL

SL yes yes yes yes

IDE CD-

ROM open open diskette

5

6

89mm

(3.5”)

89 mm

(3.5”)

SL

SL

2

2 no no

HDD on drive models open

1. A 3.5” conversion kit is standard in Bay 2 for installation of 3.5” hard disk drives.

2. Two slim-line bays can be combined to support a single half-high (HH) device.

Part

Number

Description

Ultra160 Hard Disk Drives (HDD)

00N8204 9.1GB Ultra160 SCSI HDD

00N8205 18.2GB Ultra160 SCSI HDD

00N8206 36.4GB Ultra160 SCSI HDD

External Storage Expansion Units

2

00N6xxx

4

EXP200 Storage Expansion Unit

3

1

RPM

7200

7200

7200

Height

SL

SL

SL

Form Factor

Rack (3U)

Bays

Supported

2,3,5,6

2,3,5,6

2,3,5,6

Max.

Qty.

4

4

4

37L5857

EXP200 Rack-to-Tower

Conversion Kit

3

-

37L0xxx

5

EXP200 350 W Redundant Power Supply -

1. Netfinity 3000 models P/N 771UExx and earlier contain an Ultra SCSI controller and cable which limits Ultra2 and Ultra160

HDDs to Ultra bus speeds. Netfinity 3000 models P/N 780UExx and later contain an Ultra2 SCSI controller which limits

Ultra160 HDDs to Ultra2 bus speeds.

2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see Appendix D: Cables-

Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

3. EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply and standard country power cord.

Optional hot-swap EXP200 350W Redundant Power Supply P/N 37L0xxx includes an additional standard country power cord.

To convert an EXP200 to match the system’s tower form factor, EXP200 Rack-to-Tower Conversion Kit P/N 37L5857 is required.

4. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South Africa/

English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English - Line Cords/ Publication Country Kits are included throughout.

5. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/

English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

Internal SCSI Cabling

Netfinity 3000 models 71xxxxx to 77xxxxx have a PCI Fast/Wide Ultra SCSI Adapter while models 78xxxxx and up have a PCI Wide Ultra2 SCSI Adapter. All models support up to four internal SCSI devices through the 16-bit internal connector or 15 external SCSI devices through the 16-bit external 68-pin High Density connector; however, when internal

SCSI devices are installed to the internal connector, only one SCSI device can be supported from the external connector. All models are cabled internally with a four-drop, 16-bit wide SCSI cable (models 78xxxxx and up have an Ultra2 SCSI cable), with a built-in active terminator at one end. The other end is attached to the internal 68-pin single-ended connector of the SCSI adapter. On the standard disk drive models, the hard disk drive (HDD) is attached to the cable connector closest to the active terminator. On open bay models the first disk drive installed should be attached in the same manner. In the event the standard four drop cable is attached to a RAID controller and a dedicated removable media attachment to the onboard controller is required, an optional, terminated, 16-bit cable is available (Netfinity Two-Drop Internal SCSI Cable P/N 36L9636). This is not an Ultra2 cable, therefore attached devices will operate at Ultra (or slower) speeds. If connecting narrow devices to this cable, additional 68-pin to 50-pin converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group.

61

Updated

17/10/00

Netfinity 3000 I/O Options

Part

Number

Description Adapter

Length

PCI

Support

Slots

Supported

01K7364

37L6086

19K4646

02K3454

34L1501

09N9901

34L0301

34L0701

34L5001

34L5201

37L14xx

Full

Full

Half

Half

Half

Half

Half

Half

Half

Half

Half

32-bit

32/64-bit

32/64-bit

32-bit

32-bit

32-bit

32/64-bit

32-bit

32-bit

32-bit

32-bit

3

3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

Storage Controllers

1

Netfinity ServeRAID-3L Ultra2 SCSI Adapter

2

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

3

PCI Wide Ultra160 SCSI Adapter

8

PCI Fast/Wide Ultra SCSI Adapter

Networking

4

Ethernet

Netfinity 10/100 Ethernet PCI Adapter 2

10/100 Etherlink Server Adapter by 3Com

Netfinity Gigabit Ethernet SX Adapter

Token Ring

Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

5

16/4 Token-Ring PCI Management Adapter

High speed 100/16/4 Token Ring PCI Management Adapter

Communications

Serial I/O SST 8, 16 and 128 Port Adapters

6

Systems Management

7

1. Netfinity 3000 models P/N 771UExx and earlier contain a single Fast/Wide Ultra SCSI Adapter. Netfinity 3000 models P/N 780UExx and later contain a PCI Wide Ultra2 SCSI controller.

2. Netfinity ServeRAID-3L Ultra2 SCSI Adapter P/N 01K7364 provides either one internal or one external LVDS SCSI channel.

3. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086 provides one internal and 2 external (0.8mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8mm

VHDCI) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

4. Netfinity 3000 has an integrated 10/100 PCI Ethernet Controller.

5. The Wake on LAN function of this option is not supported by Netfinity Servers.

6. See Appendix E for details on Serial I/O options and configuration limitations.

7. Netfinity 3000 provides the following integrated system management features - Vital Product Data (VPD) plus thermal, voltage, and fan sensors. For additional functions, optional PC Server Advanced

Systems Management (P/N 94G7578) may be utilised. To enable the adapter’s Automated Restart and Alerting as well as Remote Power On/Off features, Advanced Systems Management Power Unit (P/N

94G5571) is required.

8. PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm

VHDCI connector. Only one of the two connectors may be utilised.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

62

Updated

17/10/00

Netfinity 3000 Power, Monitors, Accessories

Part Number Description

Power

1

Uninterruptible Power Supply (UPS)

2

SUP072Y

SUP102Y

APC Smart-UPS 700

APC Smart-UPS 1000

Monitors

T3347xx

3

31H2Nxx

3

T32N3xx

3

T274Axx

3

11AG1xx

3

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

1.Netfinity 3000 includes a 330 W voltage sensing power supply.

2. For runtimes and UPS attributes, see Appendix C: UPS Runtime Estimate.

3. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa,

CH=Switzerland, UK=UK, EU=Europe.

Netfinity 3000 Tape Options

Part Number

09N4041

00N7991

09N4042

09N4040

Description

12/24GB DDS/3 4mm Internal SCSI Tape Drive

2,4

20/40 GB DDS/4 4-mm Internal Tape Drive

3,5

10/20GB NS Internal SCSI Tape Drive

2,4

20/40GB DLT Internal SCSI Tape Drive

Bays

Supported

SCSI Interface

(bit)

2

2

2, 3

N/A

8

16 Ultra2 LVD

8

8

Form

Factor

89 mm (3.5”)

HH or 133 mm

(5.25”) HH

89 mm (3.5”)

HH or 133 mm

(5.25”) HH

89 mm (3.5”)

SL or 133 mm

(5.25”) HH

133 mm

(5.25”) FH

Termination

Included

Y

Y

Y

N

68/50-pin

ConverterIncl.

Y

N/A

Y

Y

Ext. Tape

Enclosures

10L7440

10L7440

10L7440

03K8705

9

1

10L7440

03K8705

External Tape Enclosures

External Half High SCSI Storage Enclosure

6

DLT External SCSI Enclosure

7

-

-

8/16

16

Desktop

Desktop

N

N

N

N

-

-

10K2340

00N7956

Associated Options

Media Bay Tray and LVD Cable Kit

4,8

68-pin External Multimode LVD/SE SCSI

Terminator

-

-

16 LVD/SE

16 LVD/SE

Internal

External

Y

Y

N

N

-

10L7440,

03K8705

Note: Models P/N 780UExx and above include an Ultra2 SCSI controller with a four-drop multi-mode terminated LVD SCSI cable. Single-Ended devices attached to this cable will limit the entire SCSI bus to single-ended performance. Models P/N 771UExx and below include an Ultra SCSI controller with a four-drop,16-bit single-ended terminated SCSI cable. Support of LVD devices attached to this cable limits the LVD device to a maximum of Ultra SCSI bus speeds. All tape drives and external tape enclosures are supported by PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode

LVD SCSI cable and an external 0.8-mm VHDCI connector.

1. To determine external cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, and then refer to Appendix D:

Cables - Storage Units - Controllers.

2. This single-ended device will limit the SCSI bus of Models P/N 780UExx and above to Ultra SCSI speeds. To provide a dedicated tape SCSI bus, install PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode LVD SCSI cable.

3. Models P/N 771UExx and below will support LVD tape drives attached to the standard cable, however, bus speeds will be restricted to Ultra SCSI or below. For LVD support, optional PCI Wide Ultra160

SCSI Adapter P/N 19K4646 may be installed (includes required terminated LVD cable).

4. For RAID configurations, where the standard SCSI cable is attached to a RAID adapter, the two-drop multi-mode terminated LVD SCSI cable included with Media BayTray and LVD Cable Kit P/N 10K2340 is required, for attachment of the tape drive to the standard controller.

5. For RAID configurations, where the standard SCSI cable is attached to a RAID adapter, the two-drop multi-mode terminated LVD SCSI cable included with Media BayTray and LVD Cable Kit P/N 10K2340 is required, for attachment of the tape drive to the standard controller. For LVD support, optional PCI Wide Ultra160 SCSI Adapter P/N 19K4646 may be installed (includes required terminated LVD cable).

6. Provides a black desktop 133-mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin External

Multimode LVD/SE SCSI Terminator P/N 00N7956.

7. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires either tape drive self termination or 68-pin External Multimode LVD/SE SCSI Terminator P/N

00N7956.

8. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

9. Requires 68-pin External Multimode LVD/SE SCSI Terminator P/N 00N7956.

NOTE: Additional tape drive information can be found in Appendix A: Tape Drive Attributes.

63

Updated

17/10/00

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

Netfinity 3000 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Part Number

791UExx

00N8204

09N4042

31H2Nxx

SUP102Y

Workgroup Internet Server

Description

IBM Netfinity 3000 Pentium III 700/256KB L2, 128MB ECC, 9.1GB

IBM 9.1GB Wide Ultra160 SCSI HDD

IBM 10/20GB NS Internal SCSI Tape Drive

E54 Color Monitor 15” (13.8” Viewable Image Size), stealth black

APC Smart-UPS 1000

Quantity

1

2

1

1

1

An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an Internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (Firewall). In the case of an

Internet server, the server itself talks mostly to just one client, the Internet Service Provider(ISP), instead of many clients like a file server does.

With this in mind, the IBM Netfinity 3000 was selected to provide an affordable price point for the growing Internet server market with Pentium III processing, 128MB of system memory (expandable to 768MB), integrated 100/10 ethernet controller, high-performance storage, and power protection with an APC Smart-UPS. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

Part Number

791UExx

00N8204

09N4042

31H2Nxx

SUP072Y

File & Print Server

Description

IBM Netfinity 3000 Pentium III 700/256KB L2, 128MB ECC, 9.1GB

IBM 9.1GB Wide Ultra160 SCSI HDD

IBM 10/20GB NS Internal SCSI Tape Drive

E54 Color Monitor 15” (13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

Quantity

1

1

1

1

1

A small business or departmental server is usually required to perform all typical server functions while servicing up to 50 users in a normal workgroup computing environment, but doesn’t require the high-end performance and fault tolerance properties of larger servers. The sample configuration above consists of an IBM Netfinity 3000 with 128MB of memory and 18.2GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional internal storage expansion still available. Demanding network traffic is effectively handled by the standard 100Mbps Ethernet connection.

This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected from power surges and outages.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

64

Updated

17/10/00

65

Updated

17/10/00

IBM Netfinity 3500 M20 Configurator

721YMxx

722YMxx

731YMxx

732YMxx

741YMxx

742YMxx

24/10/00

24/10/00

-

-

-

-

667

667

733

733

800

800

1/2

1/2

1/2

1/2

1/2

1/2

256

256

256

256

256

256

128MB(R)/2GB

128MB(R)/2GB

128MB(R)/2GB

128MB(R)/2GB

128MB(R)/2GB

128MB(R)/2GB

Tower

Tower

Tower

Tower

Tower

Tower

1/1

1/1

1/1

1/1

1/1

1/1

10/100

10/100

10/100

10/100

10/100

10/100

U160

U160

U160

U160

U160

U160

4/2

4/2

4/2

4/2

4/2

4/2

0/145.6GB

9.1/145.6GB

3

0/145.6GB

9.1/145.6GB

3

0/145.6GB

9.1/145.6GB

3

40X-17X

40X-17X

40X-17X

40X-17X

40X-17X

40X-17X

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance

1. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

2. Intel Pentium III processor with 133 MHz front-side bus (FSB).

3. Standard Hard Disk Drives (HDD) are Ultra2 7200 RPM. Maximum internal capacities assume replacement of standard hard disk drives with the largest supported IBM hard disk drives.

4. Not available from IBM after this date. Business Partner inventory may be available.

Netfinity 3500 M20 Processor Upgrades

Part Number Processor Upgrades with Full Speed Cache SMP

Support

1

Processor Speed

Upgrade

2

10K3804

10K3805

10K3817

Netfinity 667 MHz/256 KB Upgrade with 133 MHz FSB Pentium III Processor

Netfinity 733 MHz/256 KB Upgrade with 133 MHz FSB Pentium III Processor

Netfinity 800 MHz/256 KB Upgrade with 133 MHz FSB Pentium III Processor

2xY

3xY

4xY

-

2xY

All 2...3xY

1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

Netfinity 3500 M20 Memory Configurator

(R) DIMM Slot 4

(R) DIMM Slot 3

(R) DIMM Slot 2

Std. (R)DIMM

(R) DIMM Slot 1

Recommended order of installation: Slot 4-3-2-1

Part Number Memory Description

1

33L3123

33L3125

33L3127

Netfinity 128 MB, 133 MHz SDRAM ECC RDIMM II

Netfinity 256 MB, 133 MHz SDRAM ECC RDIMM II

Netfinity 512 MB, 133 MHz SDRAM ECC RDIMM II

1. The recommended order of installation is in declining sequence from Slot 4 to Slot 1.

Memory size is not a factor.

Total Memory

1

128 MB

(1 x 128)

Models

256 MB

384 MB

Quantity of RDIMMs Added

128 MB

(P/N 33L3123)

256 MB

(P/N 33L3125)

512 MB

(P/N 33L3127)

1

2 or

-

1

-

-

512 MB 3 -

640 MB

896

1152 MB

1664 MB

-

-

-

-

2 or

3

-

-

1

-

2

3

4

2

2048 MB -

This table does not represent all possible memory configurations. Memory modules may vary in price per MB. Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory.

See operating system specifications for further information.

2. Requires removal of standard memory.

7/5

7/4

7/5

7/4

7/5

7/4

5/5

5/5

5/5

5/5

5/5

5/5

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

66

Updated

17/10/00

67

Updated

17/10/00

Netfinity 3500 M20 Internal Hard Disk Drive Configurator

Total Int.

Storage

1

Open Bay Examples

2

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8204)

18.2 GB

(P/N 00N8205)

36.4 GB

(P/N 00N8206)

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 00N8207)

18.2 GB

(P/N 00N8208)

36.4 GB

(P/N 00N8209)

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

54.6 GB

72.8 GB

91 GB

Note: 9.1GB disk is standard in models 7x2YMxx

2 or

3

4 or

-

-

-

-

-

1

-

2 or

-

3

4 or

-

-

-

-

1

-

-

2

-

1

2 or

3

4 or

-

-

-

-

-

1

-

2 or

-

3

4 or

-

-

-

-

1

-

-

2

-

109.2 GB

145.6 GB

(max)

-

-

-

-

3

4

-

-

-

-

3

4

This table does not represent all possible hard drive configurations.

1. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

2. Select a total storage row and then select the quantity of HDDs from a column corresponding to the appropriate hard disk drive. When configuring disk drive models P/N 7x2YMxx, which include a single

9.1GB 7200 RPM HDD, use the 9.1 GB column and order one less HDD than the table indicates.

Bay

A

B

1

C

D

E...F

G

Form Factor

133 mm (5.25”)

133 mm (5.25”)

89 mm (3.5”)

89 mm (3.5”)

89 mm (3.5”)

89 mm (3.5”)

Height

HH

HH

SL

SL

SL

SL

Front

Access

Yes

Yes

Yes

Yes

No

No

1. This bay does not support the installation of hard disk drives.

Usage

IDE CD-ROM

Open

1

Open

Diskette

Open

HDD on Drive

Models

Part

Number

Ultra160 Hard Disk Drives (HDD)

00N8204 9.1GB 7200 rpm Ultra160 SCSI HDD 7200

00N8205

18.2GB 7200 rpm Ultra160 SCSI

HDD

7200

00N8206

00N8207

36.4GB 7200 rpm Ultra160 SCSI

HDD

9.1GB 10,000 rpm Ultra160 SCSI

HDD

7200

10000

SL

SL

SL

SL

00N8208

00N8209

00N6xxx

4

37L5857

37L0xxx

5

19K11xx

6

Description

18.2GB 10,000 rpm Ultra160 SCSI

HDD

36.4GB 10,000 rpm Ultra160 SCSI

HDD

External Storage Expansion

Units

1

EXP200 Storage Expansion Unit

2

EXP200 Rack-to-Tower Conversion

Kit

EXP200 350 W Redundant Power

Supply

EXP300 Storage Expansion Unit

3

RPM

10000

10000

Form Factor

Rack (3U)

-

-

Height

SL

SL

Rack (3U)

Bays

Supported

Max.

Qty.

C,E,F,G

C,E,F,G

C,E,F,G

C,E,F,G

C,E,F,G

C,E,F,G

4

4

4

4

4

4

CD-ROM

Bay B

Bay C

Diskette

Bay E

Bay F

Bay G

09N7296

EXP300 Rack-to-Tower Conversion

Kit

-

1. No external SCSI port is available. Select an optional SCSI controller then refer to Appendix D: Cables-Storage Units-

Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable.

For HDD or other expansion unit options, see the specific expansion unit section.

2. EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply and standard country power cord. Optional hot-swap EXP200 350W Redundant Power Supply (P/N 37L0xxx) includes an additional standard country power cord. To convert an EXP200 to match the 3500 M20’s form factor, EXP200 Rack-to-Tower Conversion

Kit P/N 37L5857 is required.

3. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies, each with its own standard country power cord. To convert an EXP300 to match the 3500 M20’s form factor, EXP300 Rack-to-Tower

Conversion Kit P/N 09N7296 is required.

4. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English - Line Cords/ Publication

Country Kits are included throughout.

5. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,

079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

6.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

Internal SCSI Cabling

Netfinity 3500 M20 systems are cabled internally with a five-drop, 16-bit wide LVD SCSI cable with a built-in active terminator at one end of the cable. The other end of the cable is attached to the internal connector of the integrated Wide Ultra160 SCSI controller. For RAID configurations, the cable can be moved from the onboard to the optional RAID controller. A tape drive can then be cabled directly to the onboard or other supported adapter with the terminated, two-drop, 16-bit, LVD SCSI cable available in the Netfinity Media

Bay Conversion Kit P/N 10K2340. No external SCSI port is included.

Netfinity 3500 M20 I/O Options

Part

Number

Description

Storage Controllers

1

19K0564 Netfinity ServeRAID-3L Ultra2 SCSI Adapter II

2

37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

3

02K3454 PCI Fast/Wide Ultra SCSI Adapter

37L6091 ServeRAID-4L Ultra160 SCSI Controller

4

37L6080 ServeRAID-4M Ultra160 SCSI Controller

5

19K4646 PCI Wide Ultra160 SCSI Adapter

9

Networking

7

Ethernet

34L1501 Netfinity 10/100 Ethernet PCI Adapter 2

09N9901 10/100 EtherLink Server Adapter by 3Com

34L0301 Netfinity Gigabit Ethernet SX Adapter

Token Ring

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

Communications

8

Adapter

Length

Full

Full

Half

Full

Full

Half

Half

Half

Half

Half

PCI Support

32-bit

32/64-bit

32-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32-bit

32/64-bit

32-bit

Slots

Supported

1...5

1...5

1...5

1...5

6

1...5

6

1...5

1...5

1...5

1...5

1,,,5

Exterior Connector Access

1. Netfinity 3500 M20 includes a single channel Ultra160 SCSI controller for internal use only. No standard external port is available. See “Internal SCSI Cabling” for cabling alternatives.

2. Netfinity ServeRAID-3L Ultra2 SCSI Adapter II P/N 19K0564 provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

3. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086 provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8-mm VHDCI connector) providing a total of 3 external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

4. ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection. External connector is 0.8-mm VHDCI.

5. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external

Ultra160 connectors (only two connectors may be utilised). External connectors are 0.8-mm VHDCI.

6. ServeRAID-4L P/N 37L6091 and -4M P/N37L6080 are not supported in slots 1 or 2 if more than one RAID adapter is to be installed or more than one logical drive is to be attached to the adapter.

7. Netfinity 3500 M20 includes a full-duplex, 10/100 Mbps Ethernet PCI controller.

8. Netfinity 3500 M20 includes two USB ports, one serial and one parallel port.

9. PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm VHDCI connector. Only one of the two connectors may be utilised.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

68

Updated

17/10/00

69

Updated

17/10/00

Netfinity 3500 M20 Power, Monitors, Accessories

Part Number Description

Power

1

Uninterruptible Power Supply (UPS)

2

SUP072Y

SUP102Y

APC Smart-UPS 700

APC Smart-UPS 1000

SUP142Y APC Smart-UPS 1400

Monitors

3

T3347xx

4

31H2Nxx

4

T32N3xx

4

T274Axx

4

11AG1xx

4

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

1. Netfinity 3500 M20 includes a 330 W voltage sensing power supply.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Netfinity 3500 M20 uses an SVGA controller (S3 Savage4 chipset) with 8 MB of video memory.

4. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

Netfinity 3500 M20 Tape Options

Part

Number

Tape Drives Bays

Supported

2

SCSI

Interface

(bit)

Form

Factor

Termination

Included

68/50-pin

Converter

Incl.

Ext. Tape

Enclosures

09N4041

12/24 GB DDS/3 4-mm Internal SCSI Tape

Drive

2,3

09N4042 10/20 GB NS Internal SCSI Tape Drive

2,3

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

4

B

B, C

B

8

8

16 Ultra2 LVD

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

89 mm

(3.5”) SL or

133 mm

(5.25”) HH

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

Y

Y

Y

Y

Y

N/A

10L7440

10L7440

10L7440

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

5

Associated Options

8/16 Desktop N N -

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

10K2340 Media Bay Tray and LVD Cable Kit

3,4,6

16 LVD/SE External Y N 10L7440

16 LVD Internal Y N -

Note:All models include an Ultra160 SCSI controller with a five-drop multi-mode terminated LVD SCSI cable. Single-Ended devices attached to this cable will limit the entire SCSI bus to single-ended performance. All tape drives and external tape enclosures are supported by PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode terminated LVD SCSI cable and an external 0.8-mm VHDCI connector.

1

1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to Appendix D: Cables -

Storage Units - Controllers.

2.This single-ended device will limit the SCSI bus to which it is attached to Ultra SCSI speeds. To provide a dedicated tape SCSI bus, install PCI Wide ultra160 SCSI Adapter P/N 19K4646 which includes a five-drop multi-mode LVD SCSI cable.

3. For RAID configurations, where the standard SCSI cable is attached to a RAID adapter, the two-drop multi-mode terminated LVD SCSI cable included with Media BayTray and LVD Cable Kit P/N

10K2340 is required, for attachment of the tape drive to the standard SCSI controller.

4. For RAID configurations, where the standard SCSI cable is attached to a RAID adapter, the two-drop multi-mode terminated LVD SCSI cable included with Media BayTray and LVD Cable Kit P/N

10K2340 is required, for attachment of the tape drive to the standard SCSI controller. For LVD support, optional PCI Wide Ultra160 SCSI Adapter P/N 19K4646 may be installed (includes required terminated LVD cable).

5. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin External

Multimode LVD/SE SCSI Terminator P/N 00N7956.

6. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

Note: Additional tape information can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

Netfinity 3500 M20 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

Part Number Description

732YMxx

33L3123

00N8204

09N4042

31H2Nxx

SUP072Y

1. For a total of 256 MB of system memory.

2. For a total of 27.3 GB of internal storage.

Netfinity 3500 M20 Pentium III 733 MHz/128 MB/9.1 GB

128 MB, 133 MHz SDRAM ECC RDIMM II

1

9.1 GB Wide Ultra160 SCSI HDD

2

10/20 GB NS Internal SCSI Tape Drive

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

Quantity

1

1

2

1

1

1

An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (firewall). In the case of an

Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.

With this is mind, the IBM Netfinity 3500 M20 was selected to provide an affordable price point for the growing Internet server market with up to two-way Pentium III processing capability, 256 MB of system memory (expandable to 1 GB), and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods are used you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

File and Print Server

Part Number

731YMxx

33L3123

00N8208

00N7991

31H2Nxx

SUP072Y

1. For a total of 256 MB of system memory.

2. For a total of 54.6 GB of internal storage.

Description

Netfinity 3500 M20 Pentium III 733/128 MB/0 GB

128 MB, 133 MHz SDRAM ECC RDIMM II

1

18.2 GB 10,000 RPM Ultra160 SCSI HDD

2

20/40GB DDS/4 4mm Internal SCSI Tape Drive

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

Quantity

1

1

1

1

3

1

A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing environment, but doesn’t require the high-end performance and fault-tolerance properties of larger servers.

The sample configuration above consists of an IBM Netfinity 3500 M20 with 256 MB of memory and 54.6 GB of hard disk space. It has enough processor power and memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external storage expansion still available.

Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.

This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected during power surges and outages.

Application Server

Part Number

741YMxx

Description

Netfinity 3500 M20 Pentium III 800 MHz/128 MB/0 GB

10K3817

33L3125

37L6091

10K2340

00N8207

09N4042

31H2Nxx

SUP072Y

Netfinity 800 MHz/256 KB Upgrade with 133 MHz FSB Pentium III Processor

256 MB, 133 MHz SDRAM ECC RDIMM II

10/20 GB NS Internal SCSI Tape Drive

1

Netfinity ServeRAID-4L Ultra160 SCSI Adapter

Media Bay Tray and LVD Cable Kit

2

9.1 GB 10,000 RPM Ultra 160 SCSI HDD

3

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 700

1. For a total of 384 MB of system memory.

2. Includes a cable for dedicated attachment of the tape drive to the standard controller.

3. For a total of 27.3 GB of internal storage.

Quantity

1

1

1

3

1

1

1

1

1

An application server differs from a file and print server in that it has a higher workload, in providing application serving requirements for users. With this in mind, the IBM

Netfinity 3500 M20 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 384 MB of system memory (expandable to 2

GB), and availability features such as RAID-protected internal storage and power protection with an APC Smart-UPS.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

70

Updated

17/10/00

71

Updated

17/10/00

IBM Netfinity 4000R Configurator

865341Y 24/10/00 2 x 750

2

865344Y

5

24/10/00 2 x 750

2

865345Y 24/10/00 2 x 750

2

865346Y 24/10/00 2 x 750

2

865351Y 24/10/00 1 x 650

2

865361Y 24/10/00 2 x 650

2

865362Y 24/10/00 2 x 650

2

2/2

2/2

2/2

2/2

1/2

2/2

256

256

256

256

256

256

512MB/2GB

512MB/2GB

1GB/2GB

2GB/2GB

256MB/2GB

512MB/2GB

Rack(1U)

Rack(1U)

Rack(1U)

Rack(1U)

Rack(1U)

Rack(1U)

1/1

1/1

1/1

1/1

1/1

1/1

2 x 10/100

2 x 10/100

2 x 10/100

2 x 10/100

2 x 10/100

2 x 10/100

U

U

R-U2

R-U2

U

U

1/0

1/0

1/0

1/0

1/0

1/0

18.2/36.4

4

GB

36.4/36.4

4

GB

18.2/36.4

4

GB

36.4/36.4

4

GB

9.1/36.4

4

GB

18.2/36.4

4

GB

18.2/36.4

4

GB

24X-10X

24X-10X

24X-10X

24X-10X

24X-10X

24X-10X

3/0

3/0

3/0

3/0

3/1

3/0

2/1

2/1

2/1

2/1

2/1

2/1

2/2 256 512MB/2GB Rack(1U) 1/1 2 x 10/100 R-U2 1/0 24X-10X 3/0 2/1

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.

2. Intel Pentium III processor with advanced transfer (full speed) L2 cache.

3. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

4. Standard Hard Disk drives (HDD) are 7200 RPM. Maximum internal capacities assume factory replacement of standard hard disk drives with the largest supported IBM hard disk drives.

5. Announced as a Business Model in Europe.

6. Not available from IBM after this date. Business Partner inventory may be available.

Note: General Availability of the Netfinity 4000R is limited to and supported in the following countries only at this time:- Austria, Belgium, Denmark, Finland, France, Germany, Greece, Ireland, Israel,

Italy, Luxembourg, MEEP*, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, UK.

*MEEP includes: Bahrain, U.A.E, Jordan, Kuwait, Lebanon, Oman, Pakistan, Qatar, Saudi Arabia, Syria, Egypt, Iran, Iraq, Yemen.

Netfinity 4000R Processor Upgrades

Part

Number

1

N/A

Pentium II with 512KB Cache

SMP

Support

51Y

2

Netfinity 650 MHz/256 KB Upgrade with Pentium III Processor

1. The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.

2. One additional processor can be installed, providing a maximum of two. all processors must be identical in type, speed and cache size.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

72

Updated

17/10/00

Netfinity 4000R Memory Configurator

RDIMM Socket

RDIMM Socket

RDIMM Socket

RDIMM Socket

DIMM Description

128MB 100MHz ECC SDRAM RDIMM

256MB 100MHz ECC SDRAM RDIMM

Part Numbers

N/A

1

N/A

1

N/A

1

512MB 100MHz ECC SDRAM RDIMM

1.The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.

Netfinity 4000R Internal Hard Disk Drive Configurator

Bays Form

Factor

Height Front

Access

Usage

1

2

1

3

1

5.25”

3.5”

SL

SL yes no

IDE CD-ROM

HDD

3.5” SL no HDD

1. The Netfinity 4000R does not support customer installation of adapters,

HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features must be installed at the factory.

Contact your IBM Marketing Representative for more information

Part

Numbers

N/A

1

N/A

1

Description

9.1GB 7200rpm SCSI HDD

18.2GB 7200rpm SCSI HDD

RPM

7200

7200

Height

SL

SL

1. A maximum of two SL HDDs may be installed. The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information

Internal SCSI Cabling

Netfinity 4000R models (except 865345Y, 46Y and 62Y) contain a single channel Wide Ultra SCSI adapter that has two 68-pin connectors to support SCSI device attachment. Up to two Wide Ultra SCSI HDDs can be supported internally. Models 865345Y, 46Y and 62Y contain a single ServeRAID-3L RAID adapter for internal use only. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.

.

Netfinity 4000R I/O Options

Part

Number

Description

Storage Controllers

2

N/A

1

N/A

1

N/A

1

N/A

1

Netfinity ServeRAID-3L Ultra2 SCSI Adapter (i channel)

PCI Fast/Wide Ultra SCSI Adapter (1 channel)

Ultra SCSI Adapter (2 channel)

Ultra2 SCSI Adapter (1 channel)

Networking

3

N/A

1

N/A

1

N/A

1

Netfinity 10/100 Ethernet PCI Adapter 2

Netfinity Gigabit Ethernet SX Adapter

16/4 Token-Ring PCI Management Adapter

1. The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.

2. Netfinity 4000R models 865345Y, 46Y and 62Y contain a single channel ServeRAID-3L adapter for internal use only. Other models contain a single channel Wide Ultra SCSI adapter with an internal 68-pin connector supporting up to two internal HDDs.

3. Netfinity 4000R contains two integrated 10/100 PCI Ethernet controllers.

73

Updated

17/10/00

Netfinity 4000R Power, Monitors, Accessories

Part Number

94G7448

2PDUxxx

23

14RIxxx

22

30RIxxx

22

37L6862

T3347xx

19

31H2Nxx

19

T32N3xx

19

T274Axx

19

11AG1xx

19

Description

Power

1

Power Cable Type C12 (3.7m, 12 ft.)

2

Power Distribution Unit (PDU)

200-240V Power Distribution Unit

3

Uninterruptible Power Supply (UPS)

4

APC Smart-UPS 1400RMiB

5

APC Smart-UPS 3000RMiB

6

APC Smart-UPS 5000RMiB

7

Monitors

8

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

9

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

9

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

9

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

9

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

10

Rack and NetBay

11

930842P

930842X

9306900

9306910

36L9703

9306200

36L9702

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

12

Netfinity Rack (Perforated Doors)

12

Netfinity Rack Extension Kit

Netfinity NetBAY22

12

NetBAY22 Rack Extension Kit

Keyboard and Mouse

13

28L36xx

20

28L36xx

21

28L3675

Space Saver Keyboard

14, 15

Preferred Keyboard (stealth black)

16

Sleek 2-Button Stealth Black Mouse

Console Options

8,17

37L6888 Netfinity Flat Panel Monitor Rack Mount Kit

94G7445

28L0542

Console Server Selector Switch (8-port)

Netfinity Console Server Selector Switch (4-port)

Console Cable Set - 12 ft. (3.66m)

17,18

94G7447

1. Netfinity 4000R includes a single 150W power supply and a single 2.8 m (9 ft.) power cord for attachment to a high voltage UPS or PDU.

2. For attachment to a high voltage UPS or PDU.

3. Contains ten IEC 320-C13 outlets and three communication links, Supports up to 16 amps.

4. For runtimes and UPS attributes, see Appendix C: UPS Runtime Estimates.

5. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

6. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

7. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

8. An available port on a console switch is required for each Netfinity 4000R.

9. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).

10. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

11. Netfinity 4000R is housed in a 19” rack mountable drawer and requires one of the racks listed here. See IBM Netfinity Rack cabinet and Options section for IBM rack supported devices. To provide adequate cooling, a blank filler panel should be placed on the front of any unused rack space. If non-IBM racks are to be used, assure that both front and rear doors offer approximately

60% open area uniformly distributed and in line with installed servers. A clearance of 51 to 64-mm (2 to 2-1/2 inches) must be maintained between the front door and the system unit’s front bezel.

The rear door must maintain the same or greater clearance. Clearance between the EIA mounting rails and rack side covers must be less than 13-mm (1/2-inch) to prevent air re-circulation from back to front. Non-rack installations are not supported.

12. Rack Extension kits 36L9703 and 36L9702 are recommended for 93069xx and 9306200 respectively, to provide sufficient room for cable management.

13. The Netfinity 4000R does not include a keyboard or mouse.

14. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

15. Advanced TrackPoint IV features are not available on IBM Netfinity sy.stems.

16. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

17. The Netfinity 4000R ships with a 4 foot console cable which should be sufficient for most customer’s needs. One end of this cable plugs into the system unit, the other end has male connectors and plugs into the Console Switch, carrying the keyboard, mouse and video signals. In exceptional circumstances, should the lon ger 12 foot Console Cable P/N 94G7447 be required, a special adapter cable has to be ordered directly from the manufacturer. This adapter cable plugs into the system unit and has female connectors for keyboard, mouse and video on the outbound end, thus enabling it to be connected to the Console Cable P/N 94G7447. This adapter cable is known as the KVM cable, it has a vendor part number of 09N7179 and requests should be sent to Julie Laws at Airspeed LLC ([email protected]) or telephone 00-1-919-644-1222.

18. Required to connect server to console switch.

19.Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

20. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland,

19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

21. Where ‘ xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=UK English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

22. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom,

EUR=Europe

23. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom,

EUR=Europe..

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

74

Updated

17/10/00

75

Updated

17/10/00

IBM Netfinity 6000R Configurator

21RYMxx

1

22RYMxx

1

-

-

700 1/4 1024 512MB(R)/16GB Rack(4U) 1/3

700 1/4 2048 512MB(R)/16GB Rack(4U) 1/3

P, S,

H,F

P, S,

H,F

S-Fans

O-Power

4

S-Fans

O-Power

4

Y 10/100 D,U160 2/0

Y 10/100 D,U160 2/0

0/218.4

GB

0/218.4

GB

40X-17X 8/6

6

40X-17X 8/6

6

6/6

6/6

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 6000R Power, Monitor & Accessories” for supported IBM racks.

2. Intel Pentium III Xeon processor with full speed ECC L2 cache and 100 MHz access to memory and I/O buses. IBM intends to make available a Netfinity 6000R model containing an Intel 800 MHz/2 MB

L2 Cache Pentium II Xeon processor when Intel makes this processor generally available to the marketplace.

3. Advanced Chipkill ECC memory corrects two-, three-, and four-bit memory errors.

4. N+1 power supply redundancy requires a minimum of one optional Netfinity 270 W Hot-Swap Redundant Power Supply P/N 37L6879. Robust configurations may require two. See “Power” under

“Netfinity 6000R Power, Monitors, Accessories” for additional information.

5. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

6. Netfinity 6000R includes three hot-swap bays. Optional Netfinity 3-Pack Ultra 160 Hot-Swap Expansion Kit P/N 33L5050 expands the total hot-swap bays to six.

Netfinity 6000R Processor Upgrades

Part Number Processor Upgrades with Full Speed Cache SMP

Support

1

Processor Speed

Upgrade

2

00N7946

00N7944

Netfinity 700 MHz/1 MB Upgrade with Pentium III Xeon Processor

Netfinity 700 MHz/2 MB Upgrade with Pentium III Xeon Processor

1RY

2RY

-

1RY

1. Three additional processors may be installed, providing a maximum of four. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of four processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

1. Netfinity 6000R is housed in a 19” rack mountable drawer and requires one of the racks listed here. See “IBM Netfinity Rack Cabinet and Options” section for IBM rack supported devices.

2. Netfinity 6000R ships without a keyboard or mouse.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

5. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

6. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N

19K3831=Switzerland, 19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

7. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

76

Updated

17/10/00

77

Updated

17/10/00

Netfinity 6000R Memory Configurator

Total

Memory

1

Quantity of RDIMMs Added

2

128 MB

(P/N 33L3113)

256 MB

(P/N 33L3115)

512 MB

(P/N 33L3117)

1 GB

(P/N 33L3119)

Se t 1- J1

Set 2- J2

Set 3- J3

Set 4- J4

Set 1- J5

Set 2- J6

Set 3- J7

Set 4- J8

Std. RDIMM

Std. RDIMM

Set 1- J9

Set 2- J10

Set 3- J11

Set 4- J12

Set 1- J13

Set 2- J14

Set 3- J15

Set 4- J16

Std. RDIMM

Std. RDIMM

All RDIMMs installed in each set must be the same size, but all the sets do not have to contain RDIMMs of the same size. Install RDIMM sets in numerical sequence from 1 to 4.

512 MB

1.0 GB

1.5 GB

2.0 GB

2.5 GB

4 x 128 RDIMMs standard

4

-

4

-

-

-

4

4

8

-

-

-

-

-

-

-

-

-

-

3.0 GB

4 GB

4

4

-

4

4

4

-

-

5 GB

6 GB

3

7 GB

3

8 GB

3

9 GB

10 GB

3

12 GB

3

14 GB

3

16 GB

3

(max)

4

-

-

-

4

-

-

-

-

-

8

4

-

-

-

-

-

-

8

8

12

16

-

12

8

4

-

-

-

-

-

8

4

8

12

16

This table does not represent all possible memory configurations. Memory modules may vary in price per MB.

Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. To obtain the quantity of memory identified in the “Total Memory” column, select the appropriate row and order the quantity of RDIMMs identified in all columns for that row. Example: For 2.0 GB, order 4 x 33L3113 plus 4 x

33l3115.

3. Requires removal of standard RDIMMs.

Part Memory Description

1

Number

33L3113

33L3115

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 256 MB, 100 MHz ECC SDRAM RDIMM

33L3117

33L3119

Netfinity 512 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 1 GB 100 MHz ECC SDRAM RDIMM

1. Due to four-way interleaving all RDIMMs installed in each set must be the same size, but all the sets do not have to contain RDIMMs of the same size. Install RDIMM sets in numerical sequence from 1 to 4. Chipkill support is provided on the memory card.

Netfinity 6000R Internal Hard Disk Drive Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

18.2 GB

(P/N 37L7202)

36.4 GB

(P/N 37L7203)

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7204)

18.2 GB

(P/N 37L7205)

36.4 GB

(P/N 37L7206)

0 GB

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

54.6 GB

72.8 GB

91 GB

109.2 GB

145.6GB

182GB

3

4

2

5

2

6

2

-

1

2

-

-

-

-

Standard on Base Models

-

1

-

2

-

-

-

1

-

1

2

3

4

2

5

2

6

2

-

-

-

-

-

Standard on Base Models

-

1

-

2

-

-

-

1

-

3

4

2

5

6

-

-

-

2

2

4

5

-

2

-

3

2

2

-

3

4

2

5

2

6

2

-

-

-

2

-

3

4

2

5

2

218.4GB

(max)

6

2

6

2

This table does not represent all possible hard drive configurations.

1. Select a total storage row and then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

2. Requires Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050.

Bay Form Factor Height Front

Access

Usage Part

Number

Description RPM Height Bays

Supported

1

Max.

Qty.

-

89 mm

(3.5”)

SL Yes Diskette

Ultra160 Hard Disk Drives (HDD)

-

1...3

4...6

2

133 mm (5.25”)

HS

HS

1. Half-high (HH) devices are NOT supported.

2. To enable Bays 4...6, optional Netfinity 3-Pack Utra160 Hot-Swap Expansion Kit

P/N 33L5050 is required.

Diskette

CD-ROM

HH

SL

1

SL

1

Bay 1

Bay 2

Bay 3

Yes

Yes

Yes

Bay 4

Bay 5

Bay 6

IDE CD-

ROM

Open

Open

To enable Bays 4...6, optional Netfinity 3-Pack Ultra160 Hot-

Swap Expansion Kit (P/N 33L5050) is required.

37L7201

37L7202

37L7203

37L7204

37L7205

37L7206

19K0655

19K0656

33L5050

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap SL

HDD

36.4 GB Ultra160 SCSI Hot-Swap SL

HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

9.1 GB 15K-rpm Ultra160 SCSI Hot-

Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

7200

7200

7200

10,000

10,000

10,000

15000

15000

Associated Options

Netfinity 3-Pack Ultra160 Hot-Swap

Expansion Kit

2

-

SL

SL

SL

SL

SL

SL

SL

SL

3 x SL

1...6

1...6

1...6

1...6

1...6

1...6

1...6

1...6

4...6

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

-

00N6xxx

8

37L0xxx

9

External Storage Expansion

Units

3

EXP200 Storage Expansion Unit

4,7

EXP200 350 W Redundant Power

Supply

7

EXP300 Storage Expansion Unit

5,7

Form Factor

Rack (3U)

-

19K11xx

10

Rack (3U)

00N71xx

11

94G7448

FAStT EXP500 Storage Expansion

Unit

6,7

Rack Power Cable Type C12

(3.7m, 12 ft.)

7

Rack (3U)

-

1. Netfinity 6000R ships with bays 1...3 enabled. To enable installation of greater than three HDDs requires Netfinity 3-

Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050.

2. Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050 includes a hot-swap backplane and associated components for two cabling options. Within the option are two 16-bit LVD SCSI cables. One can be attached from the 3pack Ultra160 Hot-Swap backplane to the second connector of the dual-channel Ultra160 SCSI controller, the other, through the use of a repeater card included with the option, can be cabled directly to the standard backplane. Utilising the second channel will eliminate the possibility of attaching external devices to that channel.

3. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-

Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

4. EXP200 includes a single 2 M Ultra2 SCSI cable and single hot-swap 350W power supply. Optional hot-swap EXP200

350W Power Supply (P/N 37L0xxx) provides redundancy.

5. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies.

6. FAStT EXP500 Storage Expansion Unit includes dual hot-swap 350W power supplies.

7. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

8. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

9. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/

English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

10.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

11. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

Internal SCSI Cabling

The Netfinity 6000R contains a DASD backplane supporting three hot-swap, SCA-2 compliant drive bays. The backplane is connected to one of the internal connectors of the integrated dual-channel Ultra160 SCSI controller through a 16-bit LVD SCSI cable. An optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit

(P/N 33L5050) can be installed to provide additional internal HDD storage capacity. Within this option are two 16-bit LVD SCSI cables. One can be attached from the 3-Pack Ultra

Hot-Swap backplane to the second connector of the dual-channel Ultra160 SCSI controller, the other, through the use of a repeater card included with the option, can be cabled directly to the standard backplane.

In configurations where external SCSI device attachment is required instead of additional internal HDD storage, a second 16-bit LVD SCSI cable is included with the server. One end of the cable can be attached to the second Ultra160 connector and the other is attached to the external 0.8-mm VHDCI connector on the back of the chassis. This provides an external connection to support LVDS devices.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

78

Updated

17/10/00

79

Updated

17/10/00

Netfinity 6000R I/O Options

Part

Number

Description

Storage Controllers

3

19K0564 Netfinity ServeRAID-3L Ultra2 SCSI Adapter II

5

37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

6

37L6091 Netfinity ServeRAID-4L Ultra160 SCSI Controller

7

37L6080 Netfinity ServeRAID-4M Ultra160 SCSI Controller

8

37L6889 Netfinity ServeRAID-4H Ultra160 SCSI Controller

9

02K3454 PCI Fast/Wide Ultra SCSI Adapter

19K4646 PCI Wide Ultra160 SCSI Adapter

10

Fibre Storage Controller and Options

11

00N6881 Netfinity FAStT Host Adapter

19K11xx

22

FAStT200 Storage Server

19K11xx

23

FAStT200 HA Storage Server

19K1121 FAStT200 Redundant RAID Controller

Networking

12

Adapter

Length

Full

Full

Full

Full

Full

Half

Half

Half

-

-

-

PCI

Support

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32/64-bit

32/64-bit

-

-

-

Slots

Supported

1, 5...6

1, 5...6

1...6

4

1...6

4

1...6

4

1, 5...6

1...6

1...6

-

-

-

1

Hot-

Plug

X

-

-

X

X

X

X

-

-

X

-

2

PCI Voltage

Key

5

5

Universal

Universal

Universal

5

Universal

Universal

-

-

-

MHz

-

-

66

-

Ethernet

09N9901 Netfinity 10/100 EtherLink Server Adapter by 3Com

34L1501 Netfinity 10/100 Ethernet PCI Adapter 2

34L0301 Netfinity Gigabit Ethernet SX Adapter

Half

Half

Half

32-bit

32-bit

32/64-bit

1...6

4

1...6

4

1...6

4

X

X

X

Universal

Universal

Universal

33

33

33

Token Ring

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

13

Communications

14

37L14xx Serial I/O SST 8, 16, and 128 port adapters

15

Systems Management

16

36L96xx

21

36L9654

Netfinity Advanced System Management PCI Adapter

17, 18

03K9309 Netfinity Advanced System Management Interconnect Cable Kit

19

Netfinity Advanced System Management Token-RIng Connection

20

Half

Half

Full

-

-

32-bit

32-bit

32-bit

-

-

1...6

4

1, 5...6

1, 5...6

-

-

18

X

-

-

-

-

Universal

5

5

-

-

33

33

33

-

-

1.The 5 V - 33 MHz slots support Universal or 5 V adapters. A universal voltage-66 MHz adapter plugged into these slots will operate at 33 MHz.The 3.3 V slots support universal or 3.3 V adapters. A universal voltage-33 MHz adapter plugged into these slots limits a 66 MHz PCI adapter installed on the same bus to 33 MHz.

2. All 6 slots are full length hot-plug capable using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat

3. Netfinity 6000R includes a dual-port, dual-channel Ultra160 SCSI controller. See “Internal SCSI Cabling” for cabling alternatives.

4. Installation of a 33 MHz adapter into a Bus B 66 MHz slot will slow operation of all Bus B slots to 33 MHz.

5. Netfinity ServeRAID-3L Ultra2 SCSI Adapter II (P/N 19K0564) provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

6. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086 provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8mm VHDCI) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

7. Netfinity ServeRAID-4L Ultra160 SCSI controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and either one internal or one external Ultra160 connection. External connector is 0.8-mm VHDCI.

8. Netfinity ServeRAID-4M Ultra160 SCSI controller is powered by a 100MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external

Ultra160 connectors (only two connectors may be utilized). External connectors are 0.8-mm VHDCI.

9. Netfinity ServeRAID-4H Ultra160 SCSI controller is powered by a 266MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external Ultra160 connectors (only four connectors may be utilized). External connectors are 0.8-mm VHDCI.

10. PCI Wide Ultra160 SCSI Adapter (P/N 19K4646) provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8mm VHDCI connector. Only one of the two connectors may be utilised.

11. See Fibre Array Solutions section for additional configuration information.

12. Netfinity 6000R has an integrated 10/100 PCI Ethernet Controller.

13. The Wake on LAN function of this option is not supported by Netfinity servers.

14. Netfinity 6000R includes two USB ports, two serial and one parallel port.

15. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416) may be installed.

16. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 6000R works with Netfinity Director to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter P/N 36L96xx and Netfinity Advanced System Management Interconnect Cable Kit P/N 03K9309 additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.

17. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter which requires a separate power source. Provides an integrated 10/100

Ethernet port and PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection P/N 36L9654.

18. A maximum quantity of one is supported.

19. Required for all xSeries and Netfinity servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 1xX to 4xX are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.

20. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter, and a PC Card to 9-pin D-Shell cable which is routed to an available adapter slot opening (reduces available slots by one). The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System

Management Token-Ring Connection cannot be connected or used together.

21. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi Arabia.

22.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English 31=South

Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

23.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South

Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

33

33

66

33

33

33

33

Exterior Connector Access

Netfinity 6000R Power, Monitors, Accessories

Part Number Description

Power

1,9

37L6879

94G7448

270 W Hot-Swap Redundant Power Supply

2,9

Rack Power Cable Type C12 (3.7m, 12 ft.)

9

Uninterruptible Power Supply (UPS)

3

14RIxxx

11

30RIxxx

11

APC Smart-UPS 1400RMB

APC Smart-UPS 3000RMB

4

4

37L6862 APC Smart-UPS 5000RMB

5

Monitors

6

T3347xx

10

31H2Nxx

10

T32N3xx

10

T274Axx

10

11AG1xx

10

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image

Size), stealth black

7

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image

Size), stealth black

7

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image

Size), stealth black

7

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image

Size), stealth black

7

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0”

Viewable), stealth black

8

Part Number

930842P

930842X

9306900

9306910

36L9703

9306200

36L9702

37L6888

94G7448

28L36xx

6

28L36xx

7

Description

Rack and NetBAY

1,8

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (includes perforated front door)

Netfinity Rack Extension Kit

Netfinity NetBAY22

Netfinity NetBAY22 Rack Extension Kit

Netfinity Flat Panel Monitor Rack Mount Kit

Rack Power Cable Type C12 (3.7m)

8

Keyboard and Mouse

Space Saver II Keyboard

3, 4

Preferred Keyboard (stealth black)

5

2

28L3675 Sleek 2-Button Stealth Black Mouse

1. Netfinity 6000R systems include a single 270 W, hot-swap power supply. N+1 power supply redundancy may be achieved with the addition of optional 270 W Hot-Swap Redundant

Power Supply P/N 37L6879. Redundancy for configurations of greater than 270 W requires installation of a second optional supply. To assist in determining when an additional power supply is required to preserve redundancy, a “Non-Redundant LED” is a standard feature of the

Netfinity 6000R. The following table is provided as a reference.

Number of Power

Supplies

1

System Configuration Supported

Non-Redundant

Up to two processors

Up to three PCI adapters

Up to three HDDs

Up to eight memory RDIMMs

1. Netfinity 6000R is housed in a 19” rack mountable drawer and requires one of the racks listed here. See

“IBM Netfinity Rack Cabinet and Options” section for IBM rack supported devices.

2. Netfinity 6000R ships without a keyboard or mouse.

3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

4. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

5. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

6. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian,

50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland,

19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

7. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English,

31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

8. The Netfinity 6000R ships with a standard country power cord. For connection to a high voltage UPS or

PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

2. Netfinity 270 W Hot-Swap Redundant Power Supply P/N 37L6879 includes a single standard country power cord.

3. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

4. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

5. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

6. Netfinity 6000R uses an SVGA controller (S3 Savage4 chipset) with 8 MB of video memory.

7. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).

8. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit

P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

9. Rack Power Cable P/N 94G7448 (type C12 - one for each power supply), must be ordered for power connection to a high voltage UPS or PDU.

10. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy,

SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

11. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark,

ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,

UKM=United Kingdom, EUR=Europe

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

80

Updated

17/10/00

81

Updated

17/10/00

Netfinity 6000R Tape Options

Part

Number

Tape Drives

01K1325 20/40GB 8-mm Internal SCSI Tape Drive

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

09N4040 20/40 GB DLT Internal SCSI Tape Drive

00N7990 40/80 GB DLT Internal SCSI Tape Drive

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

Bays

Supported

N/A

1

N/A

1

N/A

1

N/A

1

N/A

1

SCSI

Interface

(bit)

16

16 Ultra2

LVD

8

16 Ultra2

LVD

16 Ultra2

LVD

Form Factor

133 mm (5.25”) HH

89 mm (3.5”) HH or

133 mm (5.25”) HH

133 mm (5.25”) FH

133 mm (5.25”) FH

133 mm (5.25”) HH

Termination

Included

N

Y

N

N

N

68/50-pin

Converter

Incl.

N

N/A

Y

N/A

N/A

Ext. Tape

Enclosures

03K8756

03K8756

2

03K8756

03K8756

2

03K8756

2

Tape Autoloaders

00N7992 120/240GB DDS/4 Tape Autoloader N/A

1

16 Ultra2

LVD

133 mm (5.25”) FH N N/A 03K8756

2

00N79xx

7

External Tape Libraries

3

DLT Tape Library

External Tape Enclosures

03K8756 NetMEDIA Storage Expansion Unit EL

4

10L7113 NetMEDIA Systems Management Adapter

5

-

-

-

16

16

16 LVD

Rack

Rack

-

Y

Y

N

N/A

N

N

-

-

03K8756

Associated Options

10K2340 Media Bay Tray and LVD Cable Kit

2,6

16 LVD Int.

Y N -

1. Netfinity 6000R does not support internal tape drives. An external tape or tape enclosure must be used. If not used internally, the second integrated Ultra160 connector may be routed to an external 0.8mm VHDCI connector with a cable included with the server. All tape drives and enclosures are supported by PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which has an external 0.8-mm VHDCI connector. Select tape drive, enclosure and supported adapter then use Appendix D: Cables-Storage Units-Controllers to select an appropriate external cable.

2.LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL P/N 03K8756 requires replacement of the standard single-ended internal cables with one or more (depending on configuration) cables from Media Bay Tray and LVD Cable Kit P/N 10K2340 which contains a single two-drop mult-mode terminated cable. If the standard cables are used for attachment to LVD devices, single-ended SCSI rules and bus speeds apply.

3. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

4. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack-mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm (5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

5. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

6. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

7 . Where ‘xx’ represents a country specific power cord code: Rack versions - 81=EU1,82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

NOTE: Additional tape drive information can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

Netfinity 6000R Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Internet Server

Part Number Description

21RYMxx

19K0564

33L5050

37L7201

01K1325

03K8756

03K9310

31H2Nxx

14RIxxx

Netfinity 6000R 700/1 MB Xeon, 512 MB(R) ECC, Open, 40X, PCI (Rack 4U)

Netfinity ServeRAID-3L Ultra2 SCSI Adapter II

Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

1

20/40 GB 8-mm Internal SCSI Tape Drive

NetMEDIA Storage Expansion Unit EL

Netfinity 2 M Ultra2 SCSI Cable

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 1400RMB

Industry Standard 19” Rack, EIA-310D, min. depth of 28” (711 mm)

9306200

28L36xx

Netfinity NetBAY22

Space Saver II Keyboard

94G6670 Blank Filler Panel Kit

1. For a total of 18.2 GB of RAID protected, hot-swap, hot-spare internal storage.

Quantity

1

1

1

1

1

4

1

1

1

1

1

2

An Internet server is a server that handles all requests from the Internet (intranet or extranet). Usually, this type of server has the same characteristics as a file server. The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (firewall). In the case of an Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.

With this in mind, the IBM Netfinity 6000R was selected to provide an affordable price point for the growing internet server market, 512 MB of system memory (expandable to 16

GB), and availability features such as RAID protected internal hot-swap storage and power protection with an APC Smart-UPS.

The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods are used, you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.

Application Server

Part Number Description

22RYMxx

00N7944

33L3113

33L3115

33L5050

37L7203

37L6086

00N7990

03K8756

10L7113

03K9310

31H2Nxx

14RIxxx

37L6879

Netfinity 6000R 700/2 MB Xeon, 512 MB(R) ECC, Open, 40X, PCI (Rack 4U)

Netfinity 700 MHz/2 MB Upgrade with Pentium III Xeon Processor

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

1

Netfinity 256 MB, 100 MHz ECC SDRAM RDIMM

1

Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit

36.4 GB Ultra160 SCSI Hot-Swap SL HDD

2

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

40/80 GB DLT Internal SCSI Tape Drive

NetMEDIA Storage Expansion Unit EL

NetMEDIA Systems Management Adapter

Netfinity 2 M Ultra2 SCSI Cable

E54 Color Monitor 15” (350 mm, 13.8” Viewable Image Size), stealth black

APC Smart-UPS 1400RMB

Netfinity 270 W Hot-Swap Redundant Power Supply

Industry Standard 19” Rack, EIA-310D, min. depth of 28” (711 mm)

9306200

28L36xx

Netfinity NetBAY22

Space Saver II Keyboard

94G6670 Blank Filler Panel Kit

1. For a total of 2 GB of system memory.

2. For a total of 109.2 GB usable RAID 5 storage.

Quantity

1

1

2

1

1

1

1

4

1

4

1

1

3

4

1

1

2

An application server is designed to handle a high workload while providing application serving requirements for users. With this in mind, the IBM Netfinity 6000R was selected to provide an affordable price point for an application server, with four-way Pentium III Xeon processing, 2 GB of system memory (expandable to 16 GB), and availability features such as battery-backed cache RAID protected internal hot-swap storage and power protection with an APC Smart-UPS.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

82

Updated

17/10/00

83

Updated

17/10/00

IBM Netfinity 7100 Configurator

611YExx 24/10/00 550 1/4 512

61RYExx

1

24/10/00 550 1/4 512

62RYExx

1

24/10/00 550 1/4 1024 256MB(R)/16GB Rack(8U) 2/4 P, H,F

63RYMxx

1

64RYMxx

1

256MB(R)/16GB

256MB(R)/16GB Rack(8U) 2/4 P, H,F

621YExx 24/10/00 550 1/4 1024 256MB(R)/16GB

631YMxx

641YMxx

-

-

-

-

700 1/4 1024 256MB(R)/16GB

700 1/4 1024 256MB(R)/16GB Rack(8U) 2/4 P, H,F

700 1/4 2048 256MB(R)/16GB

Tower

Tower

Tower

Tower

2/4 P, H,F

2/4 P, H,F

2/4 P, H,F

2/4 P, H,F

700 1/4 2048 256MB(R)/16GB Rack(8U) 2/4 P, H,F

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

S-Fans

S-Power

Y 10/100 D,U2

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

4/2 0/364GB 40X-17X 14/12 6/6

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 7100 Power, Monitor & Accessories” for supported IBM racks.

2. Intel Pentium III Xeon processor with advanced transfer (full speed) L2 cache and 100 MHz access to memory and I/O buses.

3. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

4. Not available from IBM after this date. Business Partner inventory may be available.

Netfinity 7100 Processor Upgrades

Part Number Processor Upgrades with Full Speed Cache SMP

Support

1

Processor Speed

Upgrade

2

33L5056

33L5057

10K2331

Netfinity 550 MHz/512 KB Upgrade II with Pentium III Xeon Processor

Netfinity 550 MHz/1 MB Upgrade II with Pentium III Xeon Processor

Netfinity 700 MHz/1 MB Upgrade II with Pentium III Xeon Processor

1xY

2xY

3xY

-

All 1xY

All 1...2xY

10K2332 Netfinity 700 MHz/2 MB Upgrade II with Pentium III Xeon Processor 4xY All 1...3xY

1. Three additional processors may be installed, providing a maximum of four. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of four processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

84

Updated

17/10/00

85

Updated

17/10/00

Netfinity 7100 Memory Configurator

Total

Memory

1

Quantity of RDIMMs Added

2

64 MB

(P/N 33L3067)

128 MB

(P/N 33L3113)

256 MB

(P/N 33L3115)

512 MB

(P/N 33L3117)

1 GB

(P/N 33L3119)

Se t 1- J1

Set 2- J2

Set 3- J3

Set 4- J4

Set 1- J5

Set 2- J6

Set 3- J7

Set 4- J8

Std. RDIMM

Std. RDIMM

Set 1- J9

Set 2- J10

Set 3- J11

Set 4- J12

Set 1- J13

Set 2- J14

Set 3- J15

Set 4- J16

Std. RDIMM

Std. RDIMM

All RDIMMs installed in each set must be the same size, but all the sets do not have to contain RDIMMs of the same size. Install RDIMM sets in numerical sequence from 1 to 4.

256 MB

512 MB

768 MB

1.0 GB

1.2 GB

1.7 GB

2.0 GB

2.7 GB

3.0 GB

3.2 GB

3.7 GB

4 GB

3

5 GB

3

6 GB

3

7 GB

3

8 GB

3

9 GB

3

10 GB

3

12 GB

3

14 GB

3

16 GB

3

(max)

-

-

-

-

-

-

-

-

4 x 64 RDIMMs

Standard

4

-

4

-

-

4

-

-

-

-

4

-

-

4

8

-

4

4

-

-

4

4

-

4

4

-

-

-

-

-

-

-

-

-

4

4

12

-

-

4

4

4

4

-

-

-

4

-

-

-

-

8

4

-

-

4

4

4

4

4

4

-

-

-

-

-

-

8

12

8

8

12

16

4

-

-

This table does not represent all possible memory configurations. Memory modules may vary in price per MB. Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. To obtain the quantity of memory identified in the “Total Memory” column, select the appropriate row and order the quantity of RDIMMs identified in all columns for that row. Example: For 1.0 GB, order 4 x 33L3067 and 4 x 33L3113.

3. Requires removal of standard memory DIMMs.

Part Memory Description

1

Upgrade

Number 10K2169

Compatible

2

33L3067

33L3113

Netfinity 64 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

-

X

33L3115

33L3117

33L3119

10K2169

Netfinity 256 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 512 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 1 GB 100 MHz ECC SDRAM RDIMM

3

Netfinity Active PCI/Chipkill Upgrade Kit

3

X

X

X

X

1. Due to four-way interleaving all RDIMMs installed in each set must be the same size, but all the sets do not have to contain RDIMMs of the same size. Install RDIMM sets in numerical sequence from 1 to 4.

2. Memory designated by an “X” may be used with NetfinityActive PCI/Chipkill Upgrade Kit P/N 10K2169.

3. Netfinity Active PCI/Chipkill Upgrade Kit P/N 10K2169 provides an upgrade to hot-swap PCI slots and “Chipkill” ECC memory.

-

-

-

-

-

-

-

-

-

-

-

-

4

4

8

12

16

-

-

-

Netfinity 7100 Internal Hard Disk Drive Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

2

18.2 GB

(P/N 37L7202)

2

36.4 GB

(P/N 37L7203)

2

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7204)

2

18.2 GB

(P/N 37L7205)

2

36.4 GB

(P/N 37L7206)

2

0 GB

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

54.6 GB

63.7GB

72.8 GB

81.9GB

91 GB

109.2 GB

127.4GB

145.6GB

163.8GB

182GB

7 -

8 4

9 -

2

-

3

10

-

-

-

-

-

218.4GB

-

254.8GB -

291.2 GB -

3

4

5

6

1

2

Standard on Base Models

-

1

-

-

-

-

-

-

-

1

-

-

5

6

7

8 4

9 -

10 5

-

3

-

-

2

-

6

7

8

1

2

3

4

5

6

8

9

10

-

-

-

-

-

-

-

-

Standard on Base Models

-

1

-

2

-

3

4

-

5

6

7

8

9

10

-

-

-

-

1

-

-

-

-

-

3

-

-

2

-

327.6 GB

364 GB (max)

-

-

-

-

9

10

-

-

-

-

9

10

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.

2. Netfinity 7100 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

4

-

5

6

7

8

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

86

Updated

17/10/00

87

Updated

17/10/00

Bay

-

-

RM 1

RM 2

Form

Factor

89 mm

(3.5”)

133 mm

(5.25”)

133 mm

(5.25”)

133 mm

(5.25”)

Height

SL

HH

HH

1

HH

1

Front

Access

Yes

Yes

Yes

Yes

Usage

Diskette

IDE CD-

ROM

Open

Open

Part

Number

37L7201

37L7202

37L7203

Description

Ultra160 Hard Disk Drives (HDD)

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap

SL HDD

36.4 GB Ultra160 SCSI Hot-Swap

SL HDD

RPM

7200

7200

7200

Height

SL

SL

SL

1

Bays

Supported

See diagram

See diagram

See diagram

Max.

Qty.

10

10

10

1...10 or

1...7

HS SL or HH

2

Yes Open 37L7204

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

10,000 SL See diagram 10

NB3

3

Diskette

Bay 1

Bay 2

19” Rack

1. Two half-high (HH) bays can be combined to support a single full-high

(FH) device drive can be installed in the same group. For clarity, the SCSI IDs are identified.

3. Tower configured systems support installation of up to 3 NetBAY3s. See

IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.

Removable

Media (RM)

Bays

CD-ROM

5

9

SL

0

1

3

4

10

11

13

14

3U

2

4

8

10

12

14

Open

2. The top bay is HH; all others are configured in groups of 3 SL bays. When a HH drive is installed in one of these groups, only another HH or a single SL

HH

0

Yes

Netfinity NetBAY3 (NB3)

(Optional on Tower Configurations)

Hot-Swap (HS)

Bays 10 x SL

-or-

7 x HH

(SCSI IDs

shown)

1. The top bay is HH; all others are configured in groups of three SL bays.

When a HH drive is installed in one of these groups, only another HH or a single SL drive can be installed in the same group. For clarity, the SCSI IDs are identified.

37L7205

37L7206

19K0655

19K0656

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

9.1 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

External Storage Expansion

Units

2

10,000

10,000

15,000

15,000

SL

SL

SL

SL

See diagram

See diagram

See diagram

See diagram

10

10

10

10

Form

Factor

00N6xxx

37L5857

37L0xxx

7

8

Netfinity EXP200 Storage

Expansion Unit

3, 6

Netfinity EXP200 Rack-to-Tower

Conversion Kit

Netfinity EXP200 350 W Redundant

Power Supply

6

Rack

(3U)

-

-

19K11xx

9

EXP300 Storage Expansion Unit

4, 6

Rack

(3U)

09N7296

00N71xx

10

94G7448

EXP300 Rack-to-Tower Conversion

Kit

FAStT EXP500 Storage Expansion

Unit

5, 6

Rack Power Cable Type C12

(3.7m, 12 ft.)

6

-

Rack

(3U)

-

1. Netfinity 7100 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-

Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

3. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350 W power supply. Optional hotswap Netfinity EXP200 350W Power Supply (P/N 37L0xxx) provides redundancy. To convert an EXP200 to a tower form factor, Netfinity EXP200 Rack-to-Tower Conversion Kit (P/N 37L5857) is required.

4. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500 W power supplies. To convert an EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit P/N 09N7296 is required.

5. FAStT EXP500 Storage Expansion Unit includes dual hot-swap 350 W power supplies.

6. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

7. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

8. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,

079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

9.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

10. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

Internal SCSI Cabling

The Netfinity 7100 contains a DASD backplane supporting ten hot-swap, SCA-2 compliant drive bays. The backplane is connected to Channel B of the integrated dual-channel,

Wide Ultra2 SCSI controller through a 16-bit LVD SCSI cable. Channel A only supports external SCSI attachment and is cabled directly to the external 0.8mm VHDCI SCSI connector. To support devices in the internal 133/89-mm (5.25/3.5-inch) half-high bays, a two-drop, 16-bit LVD SCSI cable with integrated terminator is included with the server.

This cable can be used to connect to an optional SCSI adapter or, in the case of RAID configurations where the backplane cable is attached to an optional RAID adapter, it can be connected to the Channel B connector.

Netfinity 7100 I/O Options

Part

Number

Description Adapter

Length

PCI Support Slots

Supported

1

Hot-

Plug

2

PCI

Voltage

Key

MHz

Storage Controllers

3

01K7364 Netfinity ServeRAID-3L Ultra2 SCSI Adapter

4

37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

5

37L6091 Netfinity ServeRAID-4L Ultra160 SCSI Controller

6

37L6080 Netfinity ServeRAID-4M Ultra160 SCSI Controller

7

37L6889 Netfinity ServeRAID-4H Ultra160 SCSI Controller

8

19K4646 PCI Wide Ultra160 SCSI Adapter

18

02K3454 PCI Fast/Wide Ultra SCSI Adapter

Fibre Storage Controller

9

00N6881 Netfinity FAStT Host Adapter

19K11xx

22

FAStT200 Storage Server

19K11xx

23

FAStT200 HA Storage Server

19K1121 FAStT200 Redundant RAID Controller

Networking

10

Ethernet

34L1501 Netfinity 10/100 Ethernet PCI Adapter 2

34L0301 Netfinity Gigabit Ethernet SX Adapter

Full

Full

Full

Full

Full

Half

Half

Half

-

-

-

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

32/64-bit

-

-

-

3...6

3...6

1...6

1...6

1...6

1...6

3...6

1...6

-

-

-

X

X

X

-

-

X

X

X

-

-

-

5

5

Universal

Universal

Universal

Universal

5

Universal

-

-

-

66

-

-

-

Half

Half

32-bit

32/64-bit

1...6

1...6

X

X

Universal

Universal

33

33

Token Ring

34L5001 16/4 Token-Ring PCI Management Adapter

11

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

11

34L5201 High speed 100/16/4 Token Ring PCI Management Adapter

Communications

12

Systems Management

13

36L96xx

21

Netfinity Advanced System Management PCI Adapter

14,15

03K9309 Netfinity Advanced System Management Interconnect Cable Kit

16

36L9654 Netfinity Advanced System Management Token-Ring Connection

17

Host Attach

10L7368 Netfinity ESCON Adapter

19,20

Half

Half

Half

Full

-

-

Full

32-bit

32-bit

32-bit

32-bit

-

-

32-bit

1...6

1...6

1...6

3...6

15

-

-

3...6

20

-

-

-

X

X

X

-

Universal

Universal

Universal

5

-

-

5

33

-

-

33

33

33

33

Other

10K2169 Netfinity Active PCI/Chipkill Upgrade Kit

2

3...6

X -

1.The 5 V slots support Universal or 5 V adapters. The 3.3 V slots support 3.3 V adapters. A Universal Keyed 66 MHz adapter plugged into a 33 MHz slot will operate at 33 MHz. A Universal Keyed 33 MHz adapter plugged into a 66 MHz slot limits other adapters installed on the same bus to 33 MHz.

2. Netfinity 7100 does not ship with hot-plug PCI slots. The addition of optional Netfinity Active PCI/Chipkill Upgrade Kit P/N 10K2169 provides slots 3-6 with hot-plug capability using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat

3.Netfinity 7100 includes a dual-port, dual-channel, 64-bit Wide Ultra2 SCSI controller with one internal connector and one external port with a 0.8-mm Very High Density Connection Interface (VHDCI).

4. Netfinity ServeRAID-3L Ultra2 SCSI Adapter P/N 01K7364 provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

5. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086 provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8mm VHDCI connector) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

6. Netfinity ServeRAID-4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel, 16 MB of ECC cache and one internal or one external Ultra160 connection.

External connectors are 0.8-mm VHDCI.

7. Netfinity ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external

Ultra160 connectors (only two connectors may be utilised). External connectors are 0.8-mm VHDCI.

8. Netfinity ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external Ultra160 connectors (only four connectors may be utilised). External connectors are 0.8-mm VHDCI.

9. See Netfinity Fibre Array Solutions section for additional configuration information.

10. Netfinity 7100 includes a full-duplex, 10/100 Mbps Ethernet PCI Controller.

11. The Wake on LAN function of this option is not supported by Netfinity servers.

12. Netfinity 7100 includes two USB ports, two high-speed serial/asynchronous ports, (NS16550A compatible), and one high-speed (up to 2 MB/sec. data transfer speed) bi-directional parallel port supporting devices using ECP/EPP/SSP protocols adhering to the IEEE 1284 standard.

13. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 7100 works with Netfinity Director to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter P/N 36L96xx and Netfinity Advanced System Management Interconnect Cable Kit P/N 03K9309 additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.

14. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter which requires a separate power source. Provides an integrated 10/100

Ethernet port and PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection P/N 36L9654.

15. A maximum quantity of one is supported.

16. Required for all xSeries and Netfinity servers containing a standard Advanced System Management Processor that is to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 1xX...4xX are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.

17. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter), and a PC Card to 9-pin D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management Token-Ring Connection cannot be connected or used together. To download the latest firmware access URL www.pc.ibm.com/us/netfinity. Select “Server Support”, “Family”, “Model”, “Downloadable files”, and finally “Advanced Systems

Management”.

18. PCI Wide Ultra160 SCSI Adapter P/N 19K4646 provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm

VHDCI connector. Only one of the two connectors may be utilised.

19. Provides an ESCON MIC and a DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.

20. A maximum of two ESCON adapters (installed in non-adjacent slots) are supported in a single server.

21. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi Arabia.

22.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English 31=South

Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

23.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South

Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

33

33

33

33

33

66

33

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

88

Updated

17/10/00

89

Updated

17/10/00

Slot 1- Bus A- 66 MHz- 3.3 V or Universal

Slot 2- Bus A- 66 MHz- 3.3 V or Universal

Slot 3- Bus B- 33 MHz- 5 V or Universal

Slot 4- Bus B- 33 MHz- 5 V or Universal

Slot 5- Bus B- 33 MHz- 5 V or Universal

Slot 6- Bus B- 33 MHz- 5 V or Universal

All Slots- Full Length, 64-bit

Netfinity 7100 Power, Monitors, Accessories

Part Number

33L37xx

10

94G7448

Description

Power

1,9

250 W Hot-Swap Redundant Power Supply

9

Rack Power Cable Type C12 (3.7m, 12 ft.)

9

Uninterruptable Power Supply (UPS)

2

SUP102Y

SUP142Y

14RIxxx

12

30RIxxx

12

37L6862

T3347xx

11

31H2Nxx

11

T32N3xx

11

T274Axx

11

11AG1xx

11

APC Smart-UPS 1000

APC Smart-UPS 1400

APC Smart-UPS 1400RMB

3

APC Smart-UPS 3000RMB

3

APC Smart-UPS 5000RMB

4

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image

Size), stealth black

6

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image

Size), stealth black

6

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image

Size), stealth black

6

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image

Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0”

Viewable), stealth black

7

1. Netfinity 7100 includes two 250W hot-swap redundant power supplies, with the ability to accept up to two additional 250 W Hot-Swap Redundant Power Supplies P/N 33L37xx. To assist in determining when an additional power supply is required to preserve redundancy, a

“Non-Redundant LED” is a standard feature of the Netfinity 7100. Predicting whether or not a particular configuration will require an additional power supply for redundancy is very complex. However, once the system is installed, the “Non-Redundant LED” will indicate when an additional power supply is required. The following sample configuration is provided as a reference.

Power Supply Quan.

2

System Configuration Supported

Typical Non-Redundant Configuration

2 x Processors

3 x PCI Adapters

4 x Half-High or 5 Slim-Line HDDs

8 x 512 MB RDIMMs

Typical Redundant Configuration

3

4

8

4 x Processors

6 x PCI Adapters

7 x Half-High or 10 Slim-Line HDDs

16 x 512 MB RDIMMs

Full Configuration with Redundancy

Part Number

37L6860

37L6859

930842P

930842X

9306900

9306910

9306200

10L6912

10L6913

37L6888

94G7448

Netfinity Caster Set

Description

Conversion Kits

8Ux24D Rack-to-Tower Kit

1

8Ux24D Tower-to-Rack Kit

Rack and NetBAY

2,10

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (includes perforated door)

Netfinity NetBAY22

Netfinity NetBAY3

3

Netfinity Flat Panel Monitor Rack Mount Kit

Rack Power Cable Type C12 (3.7m)

10

Keyboard and Mouse

4

28L36xx

8

Space Saver II Keyboard

5, 7

28L36xx

9

28L3675

Preferred Keyboard (stealth black)

6

Sleek 2-Button Stealth Black Mouse

1. Includes one Netfinity NetBAY3 with casters.

2. Netfinity 7100 rack models are housed in a 19” rack mountable drawer and require one of the racks listed here. Tower models require Netfinity 8Ux24D Tower-to-Rack Kit P/N 37L6859 for installation in a rack.

3. Netfinity 7100 tower models require Netfinity 8Ux24D Rack-to-Tower Kit P/N 37L6860 for use with a

NetBAY3. A maximum of three NetBAY3 enclosures, including the one which ships with the conversion kit, may be stacked beneath a supported Netfinity tower server. Optional NetBAY3s must be shipped separately and not while attached to the base configuration. See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.

4. Tower models includes both a mouse and keyboard. Rack models include neither.

5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

6. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

8. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian,

50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland,

19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.

9. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English,

31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

10. The Netfinity 7100 ships with a standard country power cord. For connection of a Rack model to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. Netfinity 7100 uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.

6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit P/N

37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

8. The addition of a DLT tape drive may require a fourth power supply to preserve redundancy.

9. Rack Power Cable P/N 94G7448 (type C12) - one for each Power Supply, must be ordered for power connection to a high voltage UPS or PDU.

10. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark,

63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United Kingdom&Arabia.

11. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy,

SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

12. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark,

ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,

UKM=United Kingdom, EUR=Europe

Netfinity 7100 Tape Options

Part

Number

Tape Drives

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

1

01K1325 20/40 GB 8-mm Internal SCSI Tape Drive

1

00N7990 40/80 GB DLT Internal SCSI Tape Drive

1

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

1

00N79xx

10

Tape Autoloaders

DLT Tape Autoloader

00N7992 120/240GB DDS/4 Tape Autoloader

1

External Tape Libraries

4

00N79xx

11

DLT Tape Library

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

5

03K8705 DLT External SCSI Enclosure

6

03K8756 NetMEDIA Storage Expansion Unit EL

7

10L7113 NetMEDIA Systems Management Adapter

8

Associated Options

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

10K2340 Media BayTray and LVD Cable Kit

2,9

Note: Netfinity 7100 includes an external 0.8-mm VHDCI connector.

Bays

Supported

1, 2

1, 2

1/2

1, 2

N/A

1/2

-

-

-

-

-

-

SCSI

Interface

(bit)

Form

Factor

16 Ultra2 LVD

16

16 Ultra2 LVD

16 Ultra2 LVD

89 mm

(3.5”) HH or 133 mm

(5.25”)HH

133 mm

(5.25”) HH

133-mm

(5.25”) FH

133 mm

(5.25”) HH

16

16 Ultra2 LVD

Desktop

133 mm

(5.25”) FH

16

8/16

16

16

16 LVD

16 LVD/SE

16 LVD

Desktop or

Rack

Desktop

Desktop

Rack

-

Ext.

Int.

Termination

Included

Y

N

N

N

Y

N

Y

Y

Y

N

N

Y

N

68/50-pin

Converter Incl.

N/A

N/A

N/A

N/A

N/A

N/A

-

N

N

N

N

N

N

Ext. Tape

Enclosures

10L7440,

03K8756

2

10L7440

3

,

03K8756

03K8705

3

03K8756

2

10L7440

03K8756

3

2

,

-

03K8756

2

-

-

-

-

03K8756

10L7440,

03K8705

-

1

1. Non-RAID Configurations require PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which contains a five-drop multi-mode terminated LVD SCSI cable. RAID configurations where the hot-swap backplane is cabled to a RAID controller, utilise the included two-drop multi-mode terminated LVD SCSI cable ito attach internal tapes to the onboard controller.

2. LVD support for LVD devices requires installation of the 16-bit multi-mode terminated, two-drop, SCSI cable included with optional Media Bay Tray and LVD Cable Kit P/N 10K2340.

3. Requires 68-pin External Multimode LVD/SE SCSI terminator P/N 00N7956.

4. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

5. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin External

Multimode LVD/SE SCSI Terminator P/N 00N7956.

6. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of an External Multimode LVD/SE SCSI terminator P/

N 00N7956.

7. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack or NetBAY3/3E mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm

(5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

8. NetMEDIA Systems Management Adapter (P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

9. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

10 . Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

11 . Where ‘xx’ represents a country specific power cord code: Tower versions - 74=EU1, 75=Denmark, 76=India/South Africa, 77=UK, 78=Swiss, 79=Italy, 80=Israel: Rack versions - 81=EU1,

82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

90

Updated

17/10/00

91

Updated

17/10/00

Netfinity 7100 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Part Number

641YMxx

33L3067

33L3113

33L3115

10K2332

37L7201

37L7202

00N7990

37L6086

33L37xx

T274Axx

14RIxxx

High Availability Application Server

Description

Netfinity 7100 700/2 MB Xeon, 256 MB(R) ECC, Open, 40X, PCI

Netfinity 64 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 256 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 700 MHz/2 MB Upgrade II with Pentium III Xeon Processor

9.1 GB Wide Ultra160 SCSI Hot-Swap SL HDD

18.2 GB Wide Ultra160 SCSI Hot-Swap SL HDD

40/80 GB DLT Internal SCSI Tape Drive

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

250 W Hot-Swap Redundant Power Supply

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

APC Smart-UPS 1400

Quantity

1

2

6

1

4

2

4

4

1

1

1

1

Usage

-

-

-

2 GB Total System Memory

Total of 3 SMP processors

9.1 GB mirrored for NOS

72 GB RAID 5 with hot-spare

-

RAID 1 for NOS, RAID 5 for data

Full power redundancy

UPS

This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and UPS for power even during a blackout, this server represents the leading edge in high availability. An internal tape drive is included to back up that all important asset...data. A modem could be included to allow out-of-band (non-

LAN) system management utilizing the integrated Netfinity Advanced System Management Processor.

Server Consolidation

Part Number

631YMxx

33L3113

10K2331

37L7204

3L7205

37L6086

34L1501

00N7990

33L37xx

T274Axx

14RIxxx

Description

Netfinity 7100 700 MHz/1 MB Xeon, 256 MB(R) ECC, Open, 40X, PCI (Rack 8U)

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 700 MHz/1 MB Upgrade II with Pentium III Xeon Processor

9.1 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

Netfinity 10/100 Ethernet PCI Adapter 2

40/80 GB DLT Internal SCSI Tape Drive

250 W Hot-Swap Redundant Power Supply

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

APC Smart-UPS 1400

Quantity

1

1

1

1

2

1

1

2

8

4

1

Usage

-

768 MB Total System Memory

Total of 2 SMP processors

9.1 GB mirrored for NOS

109 GB RAID 5 with hot-spare

RAID 1 for NOS, RAID 5 for data

Total of 3 Ethernet connections

-

Full Power Redundancy

-

UPS

This tower model is configured to meet the need of server consolidation. Many businesses are trying to get their arms around the dispersed departmental servers that have grown up around the enterprise. By moving multiple servers onto one platform there is only one system to manage, both hardware and software. There is potentially less expense for service, software licenses, etc., and there is no need to worry about putting all your eggs in one basket because the Netfinity 7100 is designed for high availability. This configuration includes

109 GB of internal HDD storage, features a third power supply which provides fully redundant power, a UPS to help protect the system against a momentary electricity loss, and an internal tape drive that backs up, up to 80 GB per tape...in addition to all the standard features of the Netfinity 7100.

IBM Netfinity 7600 Configurator

51RYExx

1

24/10/00 550 1/4 1024 512MB(R)/16GB Rack(8U) 3/4

52RYExx

1

24/10/00 550 1/4 2048 512MB(R)/16GB Rack(8U) 3/4

53RYExx

1

K54RYxx

1

K55RYxx

1

-

-

-

700 1/4 2048 512MB(R)/16GB Rack(8U) 3/4

700 1/4 1024 512MB(R)/16GB Rack(8U) 3/4

700 1/4 2048 512MB(R)/16GB Rack(8U) 3/4

P, S,

H,F

P, S,

H,F

P, S,

H,F

P, S,

H,F

P, S,

H,F

S-Fans

S-Power

4

S-Fans

S-Power

4

Y 10/100 D,U2,R

5

4/2 0/364GB 40X-17X 14/12 6/5

Y 10/100 D,U2,R

5

4/2 0/364GB 40X-17X 14/12 6/5

S-Fans

S-Power

4

S-Fans

S-Power

4

Y 10/100 D,U2,R

5

4/2 0/364GB 40X-17X 14/12 6/5

Y 10/100 D,U2,R

6

4/2 0/364GB 40X-17X 14/12 6/5

S-Fans

S-Power

4

Y 10/100 D,U2,R

6

4/2 0/364GB 40X-17X 14/12 6/5

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 7600 Power, Monitor & Accessories” for supported IBM racks.

2. Intel Pentium III Xeon processor with advanced transfer (full speed) L2 cache and 100 MHz access to memory and I/O buses.

3. Advanced Chipkill ECC memory - corrects two-bit, three-bit, and four-bit memory errors.

4. Robust configurations may require optional Netfinity 250 W Hot-Swap Redundant Power Supply P/N 33L37xx for redundancy. See “Power” under Netfinity 7600 Power, Monitor & Accessories” for additional information.

5. RAID adapter is equivalent to Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086.

6. RAID adapter is equivalent to ServeRAID-4M Ultra160 SCSI Controller P/N 37L6080.

7. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

8. Not available from IBM after this date. Business Partner inventory may be available.

Netfinity 7600 Processor Upgrades

Part Number Processor Upgrades with Full Speed Cache SMP

Support

1

Processor Speed

Upgrade

2

33L5057

33L5058

Netfinity 550 MHz/1 MB Upgrade II with Pentium III Xeon Processor

Netfinity 550 MHz/2 MB Upgrade II with Pentium III Xeon Processor

1RY

2RY

-

1RY

10K2331

10K2332

Netfinity 700 MHz/1 MB Upgrade II with Pentium III Xeon Processor

Netfinity 700 MHz/2 MB Upgrade II with Pentium III Xeon Processor

-

3RY

1RY, 2RY

1RY, 2RY

1. Three additional processors may be installed, providing a maximum of four. All processors must be identical in type, speed, and cache size.

2. Requires removal of the standard processor. A maximum of four processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

92

Updated

17/10/00

Netfinity 7600 Memory Configurator

Total

Memory

1

Quantity of RDIMMs Added

2

128 MB

(P/N 33L3113)

256 MB

(P/N 33L3115)

512 MB

(P/N 33L3117)

1 GB

(P/N 33L3119)

512 MB

Se t 1- J1

Set 2- J2

Set 3- J3

Set 4- J4

Set 1- J5

Set 2- J6

Set 3- J7

Set 4- J8

Std. RDIMM

Std. RDIMM

Set 1- J9

Set 2- J10

Set 3- J11

Set 4- J12

Set 1- J13

Set 2- J14

Set 3- J15

Set 4- J16

Std. RDIMM

Std. RDIMM

All RDIMMs installed in each set must be the same size , but all the sets do not have to contain RDIMMs of the same size . Install RDIMM sets in numerical sequence from 1 to 4.

1.0 GB

1.5 GB

2.0 GB

2.5 GB

3.0 GB

4 GB

5 GB

6 GB

3

7 GB

3

8 GB

3

9 GB

10 GB

3

12 GB

3

14 GB

3

16 GB

3

(max)

4 x 128 RDIMMs standard

4

-

4

-

4

4

-

4

-

4

-

-

-

-

-

-

-

-

-

-

8

4

-

-

-

8

-

4

-

4

4

-

16

-

12

8

8

12

8

4

-

-

4

4

-

-

-

-

This table does not represent all possible memory configurations. Memory modules may vary in price per MB.

Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.

2. To obtain the Quantity of memory identified in the “Total Memory” column, select the appropriate row and order the quantity of RDIMMs identified in all columns for that row. Example: For 2.0 GB, order 4 x 33L3113 plus 4 x

33l3115.

3. Requires removal of standard RDIMMs.

Part Memory Description

1

Number

33L3113

33L3115

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 256 MB, 100 MHz ECC SDRAM RDIMM

33L3117

33L3119

Netfinity 512 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 1 GB 100 MHz ECC SDRAM RDIMM

1. Due to four-way interleaving all RDIMMs installed in each set must be the same size, but all the sets do not have to contain RDIMMs of the same size. Install RDIMM sets in numerical sequence from 1 to 4. Chipkill support is provided on the memory card.

-

8

4

-

-

-

8

12

16

-

-

-

-

-

-

93

Updated

17/10/00

Netfinity 7600 Internal Hard Disk Drive Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

2

18.2 GB

(P/N 37L7202)

2

36.4 GB

(P/N 37L7203)

2

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7204)

2

18.2 GB

(P/N 37L7205)

2

36.4 GB

(P/N 37L7206)

2

0 GB

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

54.6 GB

63.7GB

72.8 GB

81.9GB

91 GB

109.2 GB

127.4GB

145.6GB

163.8GB

182GB

218.4GB

-

-

8

9

10

-

-

-

-

1

2

3

4

Standard on Base Models

-

5

6

7 -

-

3

1

-

2

4

-

5

6

7

-

-

-

-

-

-

1

2

-

-

3

-

8 4

9

10

-

-

5

6

5

6

1

2

3

4

8

9

10

-

-

-

-

-

-

Standard on Base Models

-

-

3

1

-

2

4

-

5

6

7

8

9

10

-

-

-

-

1

-

-

-

2

-

-

3

-

4

-

5

6

254.8GB -

291.2 GB -

327.6 GB

364 GB (max)

-

-

-

-

-

7

8

9

10

-

-

-

-

-

-

-

-

7

8

9

10

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.

2. Netfinity 7600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

Bay

-

-

RM 1

RM 2

1...10 or

1...7

NB3

3

Form

Factor

89 mm

(3.5”)

133 mm

(5.25”)

133 mm

(5.25”)

133 mm

(5.25”)

HS

19” Rack

Height

SL

HH

HH

1

HH

1

SL or HH

2

3U

Front

Access

Yes

Yes

Yes

Yes

Yes

Yes

Usage

Diskette

IDE CD-

ROM

Open

Open

Open

Open

Part

Number

Description RPM Height

Ultra160 Hard Disk Drives (HDD)

1

37L7201

37L7202

37L7203

37L7204

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap

SL HDD

36.4 GB Ultra160 SCSI Hot-Swap

SL HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

7200

7200

7200

10,000

37L7205

37L7206

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

10,000

10,000

SL

SL

SL

SL

SL

SL

Bays

Supported

See diagram

See diagram

See diagram

See diagram

See diagram

See diagram

Max.

Qty.

10

10

10

10

10

10

1. Two half-high (HH) bays can be combined to support a single full-high

(FH) device

2. The top bay is HH; all others are configured in groups of 3 SL bays. When a

HH drive is installed in one of these groups, only another HH or a single SL drive can be installed in the same group. For clarity, the SCSI IDs are identified.

3. Tower configured systems (Netfinity 8Ux24D Rack-to-Tower Kit, P/N

37L6860 is required and includes a single NetBAY3) support installation of up to three NetBAY3s. See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

94

Updated

17/10/00

SL

0

HH

0

19K0655

19K0656

00N6xxx

7

37L5857

37L0xxx

8

19K11xx

9

09N7296

00N71xx

10

94G7448

9.1 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

External Storage Expansion

Units

2

Netfinity EXP200 Storage

Expansion Unit

3, 6

Netfiinity EXP200 Rack-to-Tower

Conversion Kit

Netfinity EXP200 350 W Redundant

Power Supply

6

EXP300 Storage Expansion Unit

4, 6

EXP300 Rack-to-Tower Conversion

Kit

FAStT EXP500 Storage Expansion

Unit

5, 6

Rack Power Cable Type C12

(3.7m, 12 ft.)

6

15,000

15,000

Form Factor

Rack (3U)

-

-

-

SL

SL

Rack (3U)

See diagram

See diagram

10

10

Removable

Media (RM)

Bays

Diskette

CD-ROM

Bay 1

Bay 2

1

3

4

5

9

10

11

13

14

2

4

8

10

12

14

Netfinity NetBAY3 (NB3)

(Optional on Tower Configurations)

1. The top bay is HH; all others are configured in groups of three SL bays.

When a HH drive is installed in one of these groups, only another HH or a single SL drive can be installed in the same group. For clarity, the SCSI IDs are identified.

Rack (3U)

-

Hot-Swap (HS)

Bays 10 x SL

-or-

7 x HH

(SCSI IDs

shown)

1. Netfinity 7600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-

Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

3. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply. Optional hotswap Netfinity EXP200 350W Power Supply P/N 37L0xxx provides redundancy. To convert an EXP200 to a tower form factor, Netfinity EXP200 Rack-to-Tower Conversion Kit P/N 37L5857 is required.

4. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500 W power supplies. To convert an EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit P/N 09N7296 is required.

5. FAStT EXP500 Storage Expansion Unit includes dual hot-swap 350 W power supplies.

6. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

7. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

8. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,

079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

9.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

10. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

Internal SCSI Cabling

The Netfinity 7600 contains a DASD backplane supporting ten hot-swap, SCA-2 compliant drive bays. The backplane is connected to the internal connector of the standard Netfinity

ServeRAID-3HB Ultra2 SCSI Adapter through a 16-bit LVD SCSI cable. External RAID support is provided through the two external 0.8-mm VHDCI connectors on the back of the adapter. To support SCSI devices in the internal 133/89-mm (5.25/3.5-inch) half-high bays, a two-drop, 16-bit LVD SCSI cable with integrated terminator is included with the server.

This cable can be used to connect Channel B of the integrated Wide Ultra2 SCSI controller to SCSI devices in one or both of the removable media bays. Channel A, of the dualchannel, Wide Ultra2 SCSI controller, only supports external SCSI attachment and is cabled directly to an external 0.8-mm VHDCI SCSI connector.

95

Updated

17/10/00

Part

Number

Description

Storage Controllers

3

37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

4

02K3454 PCI Fast/Wide Ultra SCSI Adapter

37L6080 Netfinity ServeRAID-4M Ultra160 SCSI Controller

5

37L6889 Netfinity ServeRAID-4H Ultra160 SCSI Controller

6

19K4646 PCI Wide Ultra160 SCSI Adapter

16

Fibre Storage Controller

7

00N6881 Netfinity FAStT Host Adapter

19K11xx

20

FAStT200 Storage Server

19K11xx

21

FAStT200 HA Storage Server

19K1121 FAStT200 Redundant RAID Controller

Networking

8

Ethernet

34L1501 Netfinity 10/100 Ethernet PCI Adapter 2

09N9901 10/100 EtherLink Server Adapter by 3Com

34L0301 Netfinity Gigabit Ethernet SX Adapter

Token Ring

34L5001 16/4 Token-Ring PCI Management Adapter

9

34L0701 Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

9

34L5201 High speed 100/16/4 Token Ring PCI Management Adapter

Communications

10

Netfinity 7600 I/O Options

Adapter

Length

PCI Support Slots

Supported

1

Hot-

Plug

2

PCI

Voltage

Key

MHz

Full

Half

Full

Full

Half

Half

-

-

-

Half

Half

Half

Half

Half

Half

32/64-bit

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

-

-

-

32-bit

32-bit

32/64-bit

32-bit

32-bit

32-bit

3...6

3...6

1...6

1...6

1...6

1...6

-

-

-

1...6

1...6

1...6

1...6

1...6

1...6

X

X

-

X

-

X

X

X

X

X

X

-

-

X

-

5

5

Universal

Universal

Universal

Universal

-

-

-

Universal

Universal

Universal

Universal

Universal

Universal

33

33

33

33

33

33

-

-

66

-

33

33

33

33

66

Systems Management

11

36L96xx

19

Netfinity Advanced System Management PCI Adapter

12, 13

03K9309 Netfinity Advanced System Management Interconnect Cable Kit

14

36L9654 Netfinity Advanced System Management Token-RIng Connection

15

10L7368 Netfinity ESCON Adapter

17,18

Host Attach

Full

-

-

32-bit

-

-

3...6

13

-

-

-

-

-

5

-

-

Full 32-bit 3...6

18

5

1.The 5 V slots support Universal or 5 V adapters. The 3.3 V slots support universal or 3.3 V adapters. A Universal keyed 66 MHz adapter plugged into a 33 MHz slot will operate at 33 MHz. A

Universal keyed 33 MHz adapter plugged into a 66 MHz slot limits other adapters installed on the same bus to 33 MHz.

2. Slots 3-6 include hot-plug capability using IBM’s Active PCI technology.

3. Models P/N 51RYExx, 52RYExx and 53RYExx include a single ServeRAID-3HB Ultra2 SCSI controller as standard. Models P/N K54RYxx and K55RYxx include a single ServeRAID-4M

Ultra160 controller. One channel of these adapters is attached to the internal hot-swap backplane. Remaining channels are available for external usage just as the option would be. All models include a dual-port, dual-channel, 64-bit Wide Ultra2 SCSI controller with one internal connector and one external port with a 0.8-mm Very High Density Connection Interface (VHDCI).

4. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086 provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8-mm VHDCI connector) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in writeback cache mode in the event of a power outage or adapter maintenance.

5. Netfinity ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external Ultra160 connectors (only two connectors may be utilized). External connectors are 0.8-mm VHDCI.

6. Netfinity ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external Ultra160 connectors (only four connectors may be utilized). External connectors are 0.8-mm VHDCI.

7. See Fibre Array Solutions section for additional configuration information.

8. Netfinity 7600 includes a full-duplex, 10/100 Mbps Ethernet PCI Controller.

9. The Wake on LAN function of this option is not supported by Netfinity servers.

10. Netfinity 7600 includes two USB ports, two high-speed serial/asynchronous ports (NS16550A compatible), and one high-speed (up to 2 MB/sec. data transfer speed) bi-directional parallel port supporting devices using ECP/EPP/SSP protocols adhering to the IEEE 1284 standard.

11. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 7600 works with Netfinity Director to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter P/N 36L96xx and Netfinity Advanced System Management Interconnect Cable Kit P/N 03K9309 additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.

12. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter which requires a separate power source. Provides an integrated

10/100 Ethernet port and PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection P/N 36L9654.

13. A maximum quantity of one is supported.

14. Required for all xSeries and Netfinity servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 1...4xX are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.

15. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter, and a PC Card to 9-pin D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management Token-Ring

Connection cannot be connected or used together. To download the latest firmware access URL www.pc.ibm.com/us/netfinity. Select “Server Support”, “Family”, “Model”, “Downloadable files”, and finally “Advanced Systems Management”.

16. PCI Wide Ultra160 SCSI Adapter P/N 19K4646 provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm VHDCI connector. Only one of the two connectors may be utilised.

17. Provides an ESCON MIC and a DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.

18. A maximum of two ESCON adapters (installed in non-adjacent slots) are supported in a single server.

19. Where ‘xx’ represents a country specific code: 57=Denmark, 58=South Africa/India, 59=UK, 60=Switzerland, 61=Italy, 62=Israel, 01K7310=Europe, 01K7209=US/Saudi Arabia.

20.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English

31=South Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

21.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English,

45=South Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

33

33

-

-

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

96

Updated

17/10/00

Slot 1- Bus A- 66 MHz- 3.3 V or Universal

Slot 2- Bus A- 66 MHz- 3.3 V or Universal

Slot 3- Bus B- 33 MHz- 5 V or Universal, Active PCI

Slot 4- Bus B- 33 MHz- 5 V or Universal, Active PCI

Slot 5- Bus B- 33 MHz- 5 V or Universal, Active PCI

Slot 6- Bus B- 33 MHz- 5 V or Universal, Active PCI

RAID Adapter

All Slots- Full Length, 64-bit

Netfinity 7600 Power, Monitors, Accessories

Part Number

33L37xx

10

94G7448

Description

Power

1,9

250 W Hot-Swap Redundant Power Supply

9

Rack Power Cable Type C12 (3.7m, 12 ft.)

9

Uninterruptable Power Supply (UPS)

2

SUP102Y

SUP142Y

14RIxxx

12

30RIxxx

12

37L6862

T3347xx

11

31H2Nxx

11

T32N3xx

11

T274Axx

11

11AG1xx

11

APC Smart-UPS 1000

APC Smart-UPS 1400

APC Smart-UPS 1400RMB

3

APC Smart-UPS 3000RMB

3

APC Smart-UPS 5000RMB

4

Monitors

5

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image

Size), stealth black

6

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image

Size), stealth black

6

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image

Size), stealth black

6

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image

Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0”

Viewable), stealth black

7

1. Netfinity 7600 includes three 250W hot-swap redundant power supplies, with the ability to accept one additional 250 W Hot-Swap Redundant Power Supply P/N 33L37xx. To assist in determining when an additional power supply is required to preserve redundancy, a “Non-

Redundant LED” is a standard feature of the Netfinity 7600. Predicting whether or not a particular configuration will require an additional power supply for redundancy is very complex. However, once the system is installed, the“Non-Redundant LED” will indicate when an additional power supply is required. The following sample configuration is provided as a reference.

Number of Power

Supplies

3

8

4

System Configuration Supported

Typical Redundant Configuration

4 x Processors

6 x PCI Adapters

7 x Half-High or 10 Slim-Line HDDs

16 x 512 MB RDIMMs

Full Configuration with Redundancy

Part Number

37L6860

930842P

930842X

9306900

9306910

9306200

10L6912

37L6888

94G7448

28L36xx

8

28L36xx

9

28L3675

Description

Conversion Kits

8Ux24D Rack-to-Tower Kit

1

Rack and NetBAY

2,10

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

Netfinity Rack (includes perforated door)

Netfinity NetBAY22

Netfinity NetBAY3

3

Netfinity Flat Panel Monitor Rack Mount Kit

Rack Power Cable Type C12 (3.7m)

10

Keyboard and Mouse

4

Space Saver II Keyboard

5, 7

Preferred Keyboard (stealth black)

6

Sleek 2-Button Stealth Black Mouse

1. Includes one Netfinity NetBAY3 with casters.

2. Netfinity 7600 rack models are housed in a 19” rack mountable drawer and require one of the racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported devices.

3. Netfinity 7600 requires 8Ux24D Rack-to-Tower Kit (P/N 37L6860) for use with a NetBAY3. A maximum of three NetBAY3 enclosures, including the one which ships with the conversion kit, may be stacked beneath a supported Netfinity tower server. Optional NetBAY3s must be shipped separately and not while attached to the base configuration. See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.

4. Netfinity 7600 ships without a keyboard or mouse.

5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

6. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.

8. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian,

50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland,

19K3833=Portugal, 19L3834=Belgium, 19K3836=Russia, 19K3837=Poland.

9. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English,

31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

10. The Netfinity 7600 ships with a standard country power cord. For connection of a Rack model to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. Netfinity 7600 uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.

6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit

P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

8. The addition of a DLT tape drive may require a 4th power supply to preserve redundancy.

9. Rack Power Cable P/N 94G7448 (type C12 - one for each Power Supply), must be ordered for power connection to a high voltage UPS or PDU.

10. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark,

63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United Kingdom&Arabia.

11. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy,

SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

12. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark,

ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,

UKM=United Kingdom, EUR=Europe.

97

Updated

17/10/00

Netfinity 7600 Tape Options

Part

Number

Tape Drives Bays

Supported

SCSI

Interface

(bit)

Form

Factor

Termination

Included

68/50-pin

Converter Incl.

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

01K1325 20/40 GB 8-mm Internal SCSI Tape Drive

00N7990 40/80 GB DLT Internal SCSI Tape Drive

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

1, 2

1, 2

1/2

1, 2

16 Ultra2 LVD

16

16 Ultra2 LVD

16 Ultra2 LVD

89 mm

(3.5”) HH or 133 mm

(5.25”) HH

133 mm

(5.25”) HH

133 mm

(5.25”) FH

133 mm

(5.25”) HH

Y

N

N

N

N/A

N/A

N/A

N/A

00N79xx

9

Tape Autoloaders

DLT Tape Autoloader

00N7992 120/240GB DOS/4 Tape Autoloader

N/A

1/2

16

16 Ultra2 LVD

Desktop

133 mm

(5.25”) FH

Y

N

N/A

N/A

External Tape Libraries

3

00N79xx

10

DLT Tape Library 16

Desktop or

Rack

Y -

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

4

03K8705 DLT External SCSI Enclosure

5

03K8756 NetMEDIA Storage Expansion Unit EL

6

10L7113 NetMEDIA Systems Management Adapter

7

Associated Options

-

-

-

8/16

16

16

16 LVD

Desktop

Desktop

Rack

-

N

N

Y

N

00N7956

10K2340

68-pin External Multimode LVD/SE SCSI

Terminator

Media BayTray and LVD Cable Kit

1,8

-

-

16 LVD/SE

16 LVD

Ext.

Int.

Y

Y

N

N

Note: Netfinity 7600 includes a two-drop multimode terminated LVD SCSI cable, an available internal Ultra2 SCSI port and an external Ultra2 0.8-mm VHDCI connector.

N

N

N

N

Ext. Tape

Enclosures

10L7440,

03K8756

1

10L7440

2

,

03K8756

03K8705

03K8756

2

1

,

10L7440

03K8756

2

1

,

-

03K8756

1

-

-

-

-

03K8756

10L7440,

03K8705

-

1

1. LVD support for LVD devices requires installation of the 16-bit multi-mode terminated, two-drop, SCSI cable included with optional Media Bay Tray and LVD Cable Kit P/N 10K2340.

2. Requires 68-pin External Multimode LVD/SE SCSI terminator P/N 00N7956.

3. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

4. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin External

Multimode LVD/SE SCSI Terminator P/N 00N7956.

5. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of an External Multimode LVD/SE SCSI terminator

P/N 00N7956.

6. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack or NetBAY3/3E mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm

(5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

7. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

8. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

9. Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

10. Where ‘xx’ represents a country specific power cord code: Rack versions - 81=EU1, 82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

98

Updated

17/10/00

Netfinity 7600 Sample Configurations

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements.

Part Number

53RYExx

33L3113

33L3115

33L3117

10K2332

37L7201

37L7202

00N7990

33L37xx

T274Axx

28L36xx

14RIxxx

00N6xxx

37L0xxx

36L9750

9306200

28L0542

94G7448

94G7447

94G6670

High Availability Application Server

Description

Netfinity 7600 700/2 MB Xeon, 512 MB(R) ECC,RAID, Open, 40X, PCI (Rack 8U)

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 256 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 512 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 700 MHz/2 MB Upgrade II with Pentium III Xeon Processor

9.1 GB Wide Ultra160 SCSI Hot-Swap SL HDD

18.2 GB Wide Ultra160 SCSI Hot-Swap SL HDD

40/80 GB DLT Internal SCSI Tape Drive

250 W Hot-Swap Redundant Power Supply

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

Space Saver II Keyboard

APC Smart-UPS 1400RMB

External Storage

Netfinity EXP200 Storage Expansion Unit

Netfinity EXP200 350 W Redundant Power Supply

Netfinity 36.4 GB 10K-3 Wide Ultra2 SCSI Hot-Swap HDD

Rack

Netfinity NetBAY22

Netfinity Console Server Selector Switch (4-port)

Power Cable - Type C12

12ft Console Cable Set

Blank Filler Panel Kit

Quantity

1

1

10

1

1

1

1

6

1

3

2

4

4

1

4

1

1

1

1

1

Usage

-

-

-

4 GB Total System Memory

Total of 4 SMP processors

9.1 GB mirrored for NOS

72 GB RAID 5 with Hot-Spare

-

Full Power Redundancy

-

-

-

Includes 2-m Ultra2 cable

-

RAID 5 Data Storage with Hot-

Spare

This rack server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and UPS for power even during a blackout, this server represents the leading edge in high availability. An internal tape drive is included to back up that all important asset...data. A modem could be included to allow out-of-band (non-

LAN) system management utilizing the integrated Netfinity Advanced System Management Processor.

Server Consolidation

Part Number

53RYExx

33L3113

10K2332

37L7204

37L7205

34L1501

00N7990

T274Axx

28L36xx

14RIxxx

9306200

28L0542

94G7448

94G7447

94G6670

Description

Netfinity 7600 700/2 MB Xeon, 512 MB(R) ECC, RAID, Open, 40X, PCI (Rack 8U)

Netfinity 128 MB, 100 MHz ECC SDRAM RDIMM

Netfinity 700 MHz/2 MB Upgrade II with Pentium III Xeon Processor

9.1 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

Netfinity 10/100 Ethernet PCI Adapter 2

40/80 GB DLT Internal SCSI Tape Drive

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

Space Saver II Keyboard

APC Smart-UPS 1400RMB

Rack

Netfinity NetBAY22

Netfinity Console Server Selector Switch (4-port)

Power Cable - Type C12

12ft Console Cable Set

Blank Filler Panel Kit

Quantity

1

1

1

3

1

2

8

4

1

1

1

1

1

1

2

Usage

-

1 GB Total System Memory

Total of 2 SMP processors

9.1 GB mirrored for NOS

109 GB RAID 5 with Hot-Spare

Total of 4 Ethernet connections

-

-

-

-

-

-

Attaches to monitor

-

-

This rack server is configured to meet the need of server consolidation. Many businesses are trying to get their arms around the dispersed departmental servers that have grown up around the enterprise. By moving multiple servers on to one platform there is only one system to manage, both hardware and software. There is potentially less expense for service, software licenses, etc., and there is no need to worry about putting all your eggs in one basket because the Netfinity 7600 is designed for high availability. This configuration includes

109 GB of internal HDD storage, features three power supplies which provide fully redundant power, a UPS to help protect the system against a momentary electricity loss, and an internal tape drive that backs up, up to 80 GB per tape...in addition to all the standard features of the Netfinity 7600.

99

Updated

17/10/00

IBM Netfinity 8500R Configurator

15RYNxx

16RYNxx

1

1

24/10/00

24/10/00

550

550

1/8

1/8

1024

2048

512 MB

512 MB

R

R

/32 GB

/32 GB

Rack

(8U)

Rack

(8U)

Rack

(8U)

3/3

3/3

P, S, H,

F

P, S, H,

F

S-Fans,

S-Power

S-Fans,

S-Power

Y

Y

-

-

D, U2

D, U2

2/0

2/0

0/72.8 GB

0/72.8 GB

40X-17X

40X-17X

4/2

4/2

12/12

12/12

17RYNxx

1

700 1/8 1024 512 MB

R

/32 GB 3/3

P, S, H,

F

S-Fans,

S-Power

Y D, U2 2/0 0/72.8 GB 40X-17X 4/2 12/12

18RYNxx

1

700 1/8 2048 512 MB

R

/32 GB

Rack

(8U)

3/3

P, S, H,

F

S-Fans,

S-Power

Y D, U2 2/0 0/72.8 GB 40X-17X 4/2 12/12

* For IBM ServicePacs see Appendix F: IBM ServicePacs for Hardware Maintenance.

1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 8500R Power, Monitor & Accessories” for supported IBM racks.

2. Intel Pentium III Xeon processor.

3. Netfinity 8500R includes a systems management adapter equivalent to the one shipped with Netfinity Advanced System Management PCI Adapter P/N 36L96xx (Advanced System Management PCI

Adapter).

4. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.

5. Not available from IBM after this date. Business Partner inventory may be available.

Netfinity 8500R Processor Upgrades

Part Number Processor Upgrades with 512 KB, 1 MB or 2 MB Cache

1

SMP Support

2

Processor Speed/Cache Upgrade

3

33L5104

33L5105

28L4730

28L4727

10K2330

Netfinity 8500R 550 MHz/1 MB Upgrade with Pentium III Xeon Processor

Netfinity 8500R 550 MHz, 2 MB Upgrade with Pentium III Xeon Processor

Netfinity 8500R>4-Way Enablement Kit (1X SRAM)

5

Netfinity 8500R>4-Way Enablement Kit (4X SRAM)

5

Netfinity 8500R 700 MHz/1 MB Upgrade with Pentium III Xeon Processor

3

Netfinity 8500R 700 MHz, 2 MB Upgrade with Pentium III Xeon Processor

3

5RY

6RY

4...6RY

4

4...6RY

4

7RY

4RY

4...5RY

4...6RY

4...6RY

4...6RY

5

4...7RY

5

10K2166

10K2335

10K2337

Netfinity 4X Accelerator Filter

Netfinity Mezzanine Expansion Kit

8RY

7...8RY

4

7...8RY

4

4...7RY

4...7RY

1. Netfinity 8500R architecture optimises memory and bus performance using a 100 MHz, five-port crossbar core chipset. Up to eight Pentium III Xeon processors are supported on two 100 MHz P-6

CPU buses. The recommended order of processor installation is: Sockets A1, A3, A2, A4, B1, B3, B2, B4.

2. Up to seven additional processors may be installed, providing a maximum of eight. All processors must be identical in type, speed, and cache size.

3. Requires removal of the standard processor(s). A maximum of eight processors may be installed. Installation of greater than four processors requires the addition of a mezzanine board and two cache coherency filters. Required options which provide the board and filters vary by model. For more information refer to “Processor Upgrade Requirements”. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.

4. See “Processor Upgrade Requirements” to determine when this option is required.

5. Replacement of the standard processor mezzanine board and the mezzanine board from any installed enablement kit of 550 MHz models is required. See “Processor Upgrade Requirements” to determine specific model upgrade requirements.

Processor Upgrade Requirements

1,2

Upgrade To

Upgrade From

< 4 x 550 MHz processors

> 4 x 550 MHz processors

< 4 x 700 MHz processors

< 4 x 550 MHz processors

n/a n/a

> 4 x 550 MHz processors

1 x 28L4730 or 1 x 28L4727

n/a

< 4 x 700 MHz processors

1 x 10K2337

3

1 x 10K2337

-

3, 4

> 4 x 700 MHz processors

1 x 10K2335, 2 x 10K2337

3

2 x 10K2337

3, 5

1 x 10K2335, 1 x 10K2337

1. This table does not address the processor part numbers required. It does address the optional Enablement Kit, Filters, and Mezzanine Board part numbers required.

2. All processors must be identical in type, speed, and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in

Quick Path. Select “Downloadable files” then “BIOS”.

3. Remove the standard processor mezzanine board.

4. Remove all optional Enablement Kit components.

5. Remove Enablement Kit mezzanine board. The Enablement Kit 4X cache coherency filters are supported for use with Netfinity Mezzanine Expansion Kit P/N 10K2337.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

100

Updated

17/10/00

101

Updated

17/10/00

Netfinity 8500R ships with a single mezzanine board containing four Pentium III Xeon processor sockets with terminators in the unoccupied sockets. An additional mezzanine board may be added, expanding the number of processor sockets to eight. The two mezzanine boards are then linked through two cache coherency filter cards, one for each mezzanine board.

Netfinity 8500R > 4-Way Enablement Kits

(P/N 28L4730 and P/N 28L4727)

•Support for 550 MHz models only

•Required for installation of processors 5...8.

•One Processor Mezzanine Board

•Two cache coherency filter modules

•28L4730 economical 1X (256 K entries)

•28L4727 high performance 4X (1 M entries)

•Filters may be used with Mezzanine Expansion

Kit (P/N 10K2337)

Option Content

Netfinity 4X Accelerator Filter (P/N 10K2335)

• Two cache coherency filter modules

• Requires Mezzanine Kit 10K2337

Netfinity Mezzanine Expansion Kit (P/N 10K2337)

• One Processor Mezzanine Board

• Supports cache coherency filters from

the following options:

• P/N 10K2335

• P/N 28L4730

• P/N 28L4727

• Supports 700 MHz and above processors

only

• Required when upgrading models

8681-4RY...6RY to 700 MHz or above

Standard Mezzanine Board Optional Mezzanine Board

All installed processors must be identical in type, speed and cache size.

Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in

Quick Path. Select “Downloadable files” then “BIOS”.

A1 A2 A3 A4 B1 B2 B3 B4

Optional Cache

Coherency Filter

Cards

A B

Recommended order of processor installation is:

Sockets A1, A3, A2, A4,

B1, B3, B2, B4

Netfinity 8500R Memory Configurator

Total System

Memory

1

Quantity of RDIMMs Added

Standard Models

256 MB

(2 x 128)

384

512

512 MB

(4 x 128)

640

768

128 MB

(P/N 20L0245)

1

2 or

256 MB

(P/N 20L0247)

-

1

512 MB

(P/N 20L0249)

-

-

1 GB

(P/N 33L3056)

-

-

Memory Card A- Std.

A1 Socke

A2 Socket

A3 Socket t

Memory Card B- Optional

Std. RDIMM B1 Socket

B2 Socket

B3 Socket

A4 Socket

B4 Socket

768

1024

1280

1536

1024

1280

1536

1792

4 or

6 or

8 or

10 or

2 or

3

4 or

5

1

-

2 or

-

1

-

-

-

A5 Socket

A6 Socket

A7 Socket

A8 Socket

Std. RDIMM

B5 Socket

B6 Socket

B7 Socket

B8 Socket

1792

2304

2560

2816

3072

3328

3840

4096

4352

4864

5376

5888

6400

7424

8192

8448

9472

10496

11520

12544

13568

14592

15488

16384

16640

18688

20736

22784

24832

26880

28928

30720

32768

2048

2560

2816

3072

3328

3584

4096

-

4608

5120

5632

6144

6656

7680

8192

8704

9728

10752

11776

12800

13824

14848

15488

16384

16896

18944

20992

23040

25088

27136

29184

30720

32768

12 or

16

2 or

18

2

or

20

2

or

22

2

or

24

2

or

28

2

or

30

2 or

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

6 or

8 or

9

10 or

11

12 or

14

4

or

16

3

16

2

or

18

2

or

20

2

or

22

2

or

24

2

or

28

2

or

32

2, 3 or

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

32

3

4 or

-

5

-

6 or

7

-

8 or

9

10 or

11

12 or

14

4

or

16

3 or

16

2

or

18

2

or

20

2

or

22

2

or

24

2

or

26

2

or

28

2

or

-

2, 3

-

-

-

-

-

-

-

-

-

-

2

-

-

-

3

-

-

4

-

5

-

6

7

8

3

8

9

10

11

12

16

2

18

2

20

2

22

2

24

2

26

2

13

14

4

15

6

16

3

28

2

30

5

32

3

A9 Socket

A10 Socket

A11 Socket

A12 Socket

A13 Socket

A14 Socket

A15 Socket

A16 Socket

(J1-J16)

Std. RDIMM

Std. RDIMM

B9 Socket

B10 Socket

B11 Socket

B12 Socket

B13 Socket

B14 Socket

B15 Socket

B16 Socket

(J1-J16)

Recommended order of RDIMM population for optimum cooling: 1, 5, 9, 13, 3, 7, 11, 15, 2, 6, 10, 14, 4, 8, 12, 16.

This table does not represent all possible memory configurations. Memory modules may vary in price per MB. Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger RDIMMs.

NOTE: Cache line interleaving may be enabled by installing Netfinity 8500R Memory Expansion Card P/N 28L4454 with as few as two RDIMMs. Matched pairs must be installed if the memory expansion card is present.

1. Network Operating Systems may limit the maximum amount of addressable memory. See the operating system specifications for further information.

2. Netfinity 8500R Memory Expansion Card (P/N 28L4454) is required for installation of greater than 16 RDIMMs.

3. Requires removal of standard memory.

4. Models with 4 x 128 RDIMMs standard require Netfinity 8500R Memory Expansion Card (P/N 28L4454) for installation of greater than 16 RDIMMs.

5. Requires removal of all but two of the standard RDIMMs.

6. Requires removal of all but one of the standard RDIMMs.

Part Number Memory Description

1

20L0245

20L0247

20L0249

28L4454

Netfinity 128 MB SDRAM ECC RDIMM II

Netfinity 256 MB SDRAM ECC RDIMM II

Netfinity 512 MB SDRAM ECC RDIMM II

Netfinity 8500R Memory Expansion Card

2

33L3056 Netfinity 1 GB SDRAM ECC RDIMM II

1. Netfinity 8500R includes a single memory card with the ability to support up to 16 GB of memory. Model 14RYNxx contains two RDIMMs standard, other models contain four. For memory installation of greater than 16 GB, Netfinity 8500R Memory Expansion Card (P/N 28L4454) is required. Installation of memory on systems containing a single memory card (standard on all models) has no restrictions on size or placement. When Netfinity 8500R Memory Expansion Card (P/N 28L4454) is installed, the memory RDIMM in each socket of Card A must match the RDIMM in the same socket on Card B. To enable cache line interleaving, both memory cards must be installed and configured identically.

2. Required for enablement of cache line interleaving or installation of greater than 16 RDIMMs. Configuration of the standard memory card (Card A) and optional 28L4454 (Card B) must be identical.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

102

Updated

17/10/00

Netfinity 8500R Internal Hard Disk Drive Configurator

Total Internal

Storage

1

9.1 GB

7200 RPM Hard Disk Drives (HDDs)

(P/N 37L7201)

2

18.2 GB

(P/N 37L7202)

2

36.4 GB

(P/N 37L7203)

2

9.1 GB

(P/N 37L7204)

2

10,000 RPM HDDs

18.2 GB

(P/N 37L7205)

2

36.4 GB

(P/N 37L7206)

2

0 GB

9.1 GB

18.2 GB

1

2

Standard on Base Models

-

1

-

-

1

2

Standard on Base Models

-

1

-

-

36.4 GB

72.8 GB (max)

-

-

2

-

1

2

-

-

2

-

1

2

This table does not represent all possible hard drive configurations.

1. Select a total storage row and then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.

2. Netfinity 8500R contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

Bay

-

-

1...2

NB3E

1

Form

Factor

133 mm

(5.25”)

89 mm

(3.5”)

HS

19” Rack

Height

HH

SL

HH

3U

Front

Access

Yes

Usage

IDE CD-ROM

Yes

Yes

Yes

1. A total of three optional 3U NetBAY3Es can be stacked beneath a Netfinity

8500R which has Netfinity 8Ux28D Rack-to-Tower Kit (P/N 28L4705) installed. See IBM Netfinity NetBAY3x Stackable Enclosure section for supported devices.

CD-ROM

Diskette

Hot-Swap (HS)

Bay 1 Bay 2

Netfinity NetBAY3E (NB3E)

(Optional)

(Requires Rack to

Tower Kit)

Diskette

Open

Open

Part

Number

Description RPM Height Bays

Supported

Max

Qty.

Ultra160 Hard Disk Drives (HDD)

1

37L7201

37L7202

37L7203

37L7204

37L7205

37L7206

19K0655

19K0656

9.1 GB Ultra160 SCSI Hot-Swap SL

HDD

18.2 GB Ultra160 SCSI Hot-Swap SL

HDD

36.4 GB Ultra160 SCSI Hot-Swap SL

HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10-K Ultra160 SCSI Hot-

Swap SL HDD

9.1 GB 15K-rpm Ultra160 SCSI Hot-

Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

External Storage Expansion Units

2

7200

7200

7200

10,000

10,000

10,000

15,000

15,000

SL

SL

SL

SL

SL

SL

SL

SL

1, 2

1, 2

1, 2

1, 2

1, 2

1, 2

1, 2

1, 2

2

2

2

2

2

2

2

2

Form Factor

00N6xxx

37L5857

37L0xxx

19K11xx

7

8

09N7296

9

Netfinity EXP200 Storage Expansion

Unit

3, 6

Netfinity EXP200 Rack-to-Tower

Conversion Kit

Netfinity EXP200 350 W Redundant

Power Supply

6

EXP300 Storage Expansion Unit

4, 6

EXP300 Rack-to-Tower Conversion

Kit

Rack (3U)

Tower

-

Rack (3U)

-

00N71xx

10

94G7448

FAStT EXP500 Storage Expansion

Unit

5, 6

Rack Power Cable Type C12

(3.7m, 12 ft.)

6

Rack (3U)

-

1. Netfinity 8500R contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.

2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-

Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.

3. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply. Optional hotswap Netfinity EXP 350W Power Supply P/N 37L0xxx provides redundancy. To convert an EXP200 to a tower form factor, Netfinity EXP200 Rack-to-Tower Conversion Kit P/N 09N7296 is required.

4. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies. To convert an

EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit P/N 09N7296 is required.

5. FAStT EXP500 Storage Expansion Unit includes dual hot-swap 350 W power supplies.

6. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

7. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,

902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South

Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

8. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,

079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are included throughout.

9.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

10. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/

Language Line Cords/Publications are included as indicated.

103

Updated

17/10/00

Internal SCSI Cabling

Netfinity 8500R systems contains an LVDS backplane supporting two hot-swap drive bays that support installation of up to two 3.5-inch, slim-high or half-high HDDs. The backplane is connected to the internal Wide Ultra2 SCSI controller through a 16-bit LVD SCSI cable. RAID support for the internal hot-swap drive bays is provided by adding a supported RAID adapter and moving the standard SCSI cable from the onboard controller to the optional RAID controller. The standard external Wide Ultra2 SCSI port uses a 0.8-mm Very High Density Connector Interface (VHDCI).

.

Netfinity 8500R I/O Options

Part

Number

Description Adapter

Length

PCI

Support

Slots

Supported

1

Hot-

Plug

2

PCI Voltage

Key

MHz

01K7364

37L6086

37L6080

37L6889

19K4646

02K3454

Storage Controllers

3

Netfinity ServeRAID-3L Ultra2 SCSI Adapter

4

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

5

ServeRAID-4M Ultra160 SCSI Controller

6

ServeRAID-4H Ultra160 SCSI Controller

7

PCI Wide Ultra160 SCSI Adapter

10

PCI Fast/Wide Ultra SCSI Adapter

Fibre Storage Controller

9

Netfinity FAStT Host Adapter

FAStT200 Storage Server

FAStT200 HA Storage Server

Full

Full

Full

Full

Half

Half

32-bit

32/64-bit

32/64-bit

32/64-bit

32/64-bit

32-bit

(1...5, 10...12)

8

(1...5, 10...12)

8

1...12

1...12

1...12

1...5, 10...12

X

X

X

X

-

-

5

5

Universal

Universal

Universal

5

33

33

33

33

66

33

00N6881

19K11xx

22

19K11xx

23

19K1121

Half

-

-

-

32/64-bit

-

-

-

1...12

-

-

-

X

-

-

-

Universal

-

-

-

66

-

-

-

34L1501

09N9901

34L0301

FAStT200 Redundant RAID Controller

Networking

11

Ethernet

Netfinity 10/100 Ethernet PCI Adapter 2

10/100 EtherLink Server Adapter by 3Com

Netfinity Gigabit Ethernet SX Adapter

Half

Half

Half

32-bit

32-bit

32/64-bit

1...12

1...12

1...12

X

X

X

Universal

Universal

Universal

33

33

33

34L5001

34L0701

34L5201

37L14xx

03K9309

36L9654

02K65xx

21

Token Ring

16/4 Token-Ring PCI Management Adapter

12

Token-Ring 16/4 PCI Adapter 2 with Wake on LAN

12

High speed 100/16/4 Token Ring PCI Management Adapter

Communications

13

Serial I/O SST 8, 16 and 128 Port Adapters

14

Systems Management

15

Netfinity Advanced System Management Interconnect Cable Kit

16

Netfinity Advanced System Management Token-Ring Connection

17

UltraSlim 56W AC Adapter

18

Half

Half

Half

32-bit

32-bit

32-bit

Half 32-bit

-

-

-

-

-

-

-

-

-

1...12

1...12

1...12

10...12)

14

X

X

-

-

-

-

-

Universal

Universal

Universal

5

-

-

-

-

-

-

33

33

33

33

10L7368

Host Attach

Netfinity ESCON Adapter

19, 20

Full 32-bit (1...5, 10...12)

20

5 33

1. The P-6 I/O bus supports four independent 64-bit PCI buses, two of which drive eight 33 MHz, 5.0 V slots (1-5, 10-12), while the other two buses drive four 66 MHz, 3.3 V slots (6-9). The 5 V slots support

Universal or 5 V adapters. A 66 MHz adapter plugged into these slots will operate at 33 MHz. The 3.3 V slots support Universal or 3.3 V adapters. A 33 MHz adapter plugged into these slots limits a 66 MHz

PCI adapter installed on the same bus to 33 MHz.

2. All 12 Slots are hot-plug capable using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat.

3. Netfinity 8500R includes a dual-port, dual-channel, 64-bit Wide Ultra2 SCSI controller which supports either Single Ended (SE) or Low Voltage Differential SCSI (LVDS) modes. One internal connector and one external port with a 0.8-mm Very High Density Connection Interface (VHDCI) are standard. The internal LVD SCSI cable has sufficient length to attach to an adapter located in slots 10...12. If a boot device (internal or external) is to be attached to an adapter, the adapter must reside in slots 10...12 due to BIOS scanning sequences.

4. Netfinity ServeRAID-3L Ultra2 SCSI Adapter P/N 01K7364 provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.

5. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter P/N 37L6086 provides one internal and two external (0.8 mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external usage (0.8 mm VHDCI) providing a total of three external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache, which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintenance.

6. ServeRAID-4M Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides two channels, 64 MB of battery-backed ECC cache and two internal and two external Ultra160 connectors (only two connectors may be utilised). External connectors are 0.8-mm VHDCI.

7. ServeRAID-4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery-backed ECC cache with two internal and up to four external Ultra160 connectors (only four connectors may be utilised). External connectors are 0.8-mm VHDCI.

8. A total quantity of eight, in any combination of 01K7364 and 37L6086 is supported.

9. See Fibre Channel Solutions section for additional configuration information.

10. PCI Wide Ultra160 SCSI Adapter P/N 19K4646 provides a single channel with one internal connector and a five-drop multi-mode terminated LVD SCSI cable and one external connector with a 0.8-mm

VHDCI connector. Only one of the two connectors may be utilised.

11. Netfinity 8500R does not include an onboard network controller.

12. The Wake on LAN function of this option is not supported by Netfinity servers.

13. Netfinity 8500R includes two USB ports, two high-speed serial/asynchronous ports, (NS 16550A compatible), and one high-speed (up to 2 MBps data transfer speed) bi-directional parallel port supporting devices using ECP/EPP/SSP protocols adhering to the IEEE 1284 standard.

14. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416) may be installed.

15. Netfinity 8500R ships standard with a Netfinity Advanced System Management PCI Adapter.

16. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection

(Netfinity 5500 models 1xX...4xX are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft). A customer-supplied Ethernet cable is required for each interconnection.

17. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter and a PC Card to 9-pin D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management Token-Ring Connection cannot be connected or used together. To download the latest firmware, access URL www.ibm.com/pc/us/netfinity. Select “Server Support”, “Family”, “Model”, “Downloadable Files” and finally “Advanced System Management”.

18. Although the 8500R integrated Netfinity Advanced System Management PCI Adapter is powered continuously through the redundant power supply subsystem, an even higher level of availability is offered with the addition of UltraSlim 56W AC Adapter by allowing an independent power source or connection to a separate optional UPS.

19. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.

20. A maximum of two ESCON adapters (installed in non-adjacent slots) are supported in a single Netfinity server. Where possible, install in a minimally loaded bus.

21. Where ‘xx’ represents a country specific code: 84=Denmark, 89=Israel, 88=Italy, 85=South Africa/India, 87=Switzerland, 86=UK, 83=EU1.

22.Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English 31=South

Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

23.Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South

Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

104

Updated

17/10/00

Full Length, 64-bit, Hot-Plug PCI Slots

Netfinity 8500R Power, Monitors, Accessories

Part

Number

Description

94G7448

30RIxxx

10

37L6862

Power

1

Rack Power Cable Type C12 (3.7m, 12 ft.)

8

Uninterruptible Power Supply (UPS)

2

APC Smart-UPS 3000RMB

3

APC Smart-UPS 5000RMB

4

Monitors

5

T3347xx

31H2Nxx

9

9

E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

6

E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black

6

T32N3xx

9

E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black

6

T274Axx

11AG1xx

9

9

G78 Color Monitor 17” (454-mm, 17.9” Viewable Image Size), stealth black

6

T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable), stealth black

7

1.Netfinity 8500R systems contain three 750 W (at 220 V), hot-swap power supplies which handle robust configurations while providing full redundancy. Even though multiple UPSs may provide redundant power sources, systems management software does not currently take advantage of its power outage alerts.

2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimates.

3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.

4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.

5. Netfinity 8500R uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.

6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.

7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit

P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist within the same keyboard tray.

8. Rack Power Cable P/N 94G7448 (type C12 - one for each Power Supply), must be ordered for power connection to a high voltage UPS or PDU.

9. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi

Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.

10. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel,

ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom,

EUR=Europe.

Part Number

28L4705

930842P

930842X

9306900

9306910

36L9703

9306200

8Ux28D Rack-to-Tower Kit

1

Rack and NetBAY

2,12

Netfinity Enterprise Rack

Netfinity Enterprise Expansion Cabinet

Netfinity Rack

3

Netfinity Rack

3

(includes perforated front door)

Netfinity NetBAY22

4

Description

Conversion Kits

Netfinity Rack Extension Kit

36L9702 NetBAY22 Rack Extension Kit

36L9701 Netfinity NetBAY3E

5

37L6888

94G7448

28L36xx

10

28L36xx

11

Netfinity Flat Panel Monitor Rack Mount Kit

Rack Power Cable Type C12 (3.7m)

12

Keyboard and Mouse

6

Space Saver Keyboard

7, 8

Preferred Keyboard (stealth black)

9

28L3675 Sleek 2-Button Stealth Black Mouse

1. Includes one Netfinity NetBAY3E with casters.

2. Netfinity 8500R is housed in a 19” rack mountable drawer and requires one of the racks listed here. See “IBM Netfinity Rack Cabinet and Options” section for IBM rack supported devices.

3. Netfinity Rack Extension Kit P/N 36L9703 is required for proper rear door closure clearance.

4. NetBAY22 Rack Extension Kit P/N 36L9702 is required for proper rear door closure clearance.

5. A maximum of three NetBAY3E enclosures may be stacked beneath a supported Netfinity tower server (conversion kit P/N 28L4705 required). See IBM Netfinity NetBAY3X Stackable Enclosure section for supported devices.

6.Netfinity 8500R ships without a keyboard or mouse.

7. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).

8. Advanced TrackPoint IV features are not available on IBM Netfinity sy.stems.

9. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.

10. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany,

49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland,

19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia,

19K3837=Poland.

11. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian,

29=English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.

12. The Netfinity 8500R ships with a standard country power cord. For connection to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.

105

Updated

17/10/00

.

Netfinity 8500R Tape Options

Part

Number

Description

00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive

01K1325 20/40 GB 8-mm Internal SCSI Tape Drive

09N4040 20/40 GB DLT Internal SCSI Tape Drive

00N7990 40/80 GB DLT Internal SCSI Tape Drive

00N8017 60/120GB 8-mm M2 SCSI Tape Drive

Bays

Supported

N/A

N/A

N/A

N/A

N/A

SCSI

Interface

(bit)

16 Ultra2

LVD

16

8

16 Ultra2

LVD

16 Ultra2

LVD

Form Factor

89 mm (3.5”) HH or

133 mm (5.25”) HH

133 mm (5.25”) HH

133 mm (5.25”) FH

133 mm (5.25”) FH‘

133 mm (5.25”) HH

Termination

Included

Y

N

N

N

N

68/50-pin

Converter

Incl.

N/A

N/A

Y

N/A

N/A

Ext. Tape

Encl.

10L7440

03K8756

1

10L7440

2

03K8756

03K8705

2

,

03K8756

03K8705

03K8756

2

1

,

10L7440

03K8756

2

1

,

00N79xx

9

Tape Autoloaders

DLT Tape Autoloader

00N7992 120/240GB DDS/4 Tape Autoloader

-

N/A

16

16 Ultra2

LVD

Desktop

133 mm (5.25”) FH

Y

N

N/A

N/A

-

03K8756

1

External Tape Libraries

3

00N79xx

10

DLT Tape Library

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

4

03K8705 DLT External SCSI Enclosure

5

03K8756 NetMEDIA Storage Expansion Unit EL

6

10L7113 NetMEDIA Systems Management Adapter

7

Associated Options

-

-

-

-

-

16

8/16

16

16

16 LVD

Desktop or Rack

Desktop

Desktop

Rack

-

Y

N

N

Y

N

-

N

N

N

N

-

-

-

-

03K8756

00N7956

68-pin External Multimode LVD/SE SCSI

Terminator

10K2340 Media BayTray and LVD Cable Kit

1,8

16 LVD/SE Ext.

Y N

10L7440,

03K8705

16 LVD Int.

Y N

Note: Netfinity 8500R does not support internal tape drives but does include an external Ultra2 0.8-mm VHDCI SCSI connector for attachment of an external tape or tape enclosure. All tape drives and enclosures are also supported by PCI Wide Ultra160 SCSI Adapter P/N 19K4646 which has an external 0.8-mm VHDCI connector. Select tape drive, enclosure and controller then use Appendix D: Cables-

Storage Units-Controllers to select an appropriate external cable

1. LVD support for LVD devices requires installation of the 16-bit multi-mode terminated, two-drop, SCSI cable included with optional Media Bay Tray and LVD Cable Kit P/N 10K2340.

2. Requires 68-pin External Multimode LVD/SE SCSI terminator P/N 00N7956.

3. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.

4. Provides a black desktop 133 mm (5.25”) half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or 68-pin External

Multimode LVD/SE SCSI Terminator P/N 00N7956.

5. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of an External Multimode LVD/SE SCSI terminator

P/N 00N7956.

6. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack or NetBAY3/3E mountable tape enclosure which includes two full high (FH) or four half high (HH) extended length 133 mm

(5.25”) bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two power cords are also included.

7. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

8. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

9. Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

10. Where ‘xx’ represents a country specific power cord code: Tower versions - 74=EU1, 75=Denmark, 76=India/South Africa, 77=UK, 78=Swiss, 79=Italy, 80=Israel: Rack versions - 81=EU1,

82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

Note: Additional tape attributes can be found in Appendix A: Tape Drive Attributes.

Note: For a complete list of all IBM and non-IBM options compatibility with Network Operating Systems and IBM xSeries and Netfinity Servers, access the IBM Proven compatibility pages on the Web at URL http://www.pc.ibm.com/us/compat

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

106

Updated

17/10/00

Netfinity 8500R Sample Configurations

The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing

Representative for assistance with your specific configuration requirements.

High Availability-Rack

Part Number

18RYNxx

10K2166

10K2335

10K2337

20L0247

28L4454

37L7201

37L6086

34L1501

31H2Nxx

28L36xx

30RIxxx

03K8756

00N7990

00N6xxx

37L0xxx

03K9311

37L7204

9306200

36L9702

94G7448

94G6670

Description

Netfinity 8500R (PIII Xeon 700/2MB 512 MB/Rack) (8U)

Netfinity 8500R 700 MHz/2MB Upgrade with Pentium III Xeon Processor

Netfinity 4X Accelerator Filter

Netfinity Mezzanine Expansion Kit

Netfinity 256 MB SDRAM ECC RDIMM II

Netfinity 8500R Memory Expansion Card

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

Netfinity 10/100 Ethernet PCI Adapter 2

E54 Color Monitor 15” (13.8” Viewable Image Size), stealth black

Space Saver Keyboard

APC Smart-UPS 3000RMB

External Storage

NetMEDIA Storage Expansion Unit EL

40/80 GB DLT Internal SCSI Tape Drive

Netfinity EXP200 Storage Expansion Unit

Netfinity EXP200 350 W Redundant Power Supply

Netfinity 4.2 M Ultra2 SCSI Cable

9.1 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

Rack Options

Netfinity NetBAY22

NetBAY22 Rack Extension Kit

Power Cable - Type C12

Blank Filler Panel Kit

Quantity

1

5

1

1

1

5

1

2

6

1

1

1

2

1

8

1

1

1

2

1

1

1

Usage

Power Redundancy standard

Total of 6 SMP processors

Required for greater than 4 processors in this model

Required for greater than 4 processors in this model

Total of over 2 GB of memory

Enables cache line interleaving

NOS mirroring

RAID Controller - NOS plus EXP200

-

-

-

-

External Tape Drive Enclosure

Installs in 03K8756

Provides additional 10 bays

-

Tape to Onboard SCSI, 3-HB to EXP200

RAID 5 with Hot-Spare in EXP200

Monitor and keyboard mount on top

Required for rear door closure

-

-

This high availability server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. The configuration includes enough disk drives to mirror the operating system and provide a RAID 5 data environment, power supply redundancy by the server and EXP200 and a UPS for power even during a blackout. A rack mounted tape drive is included to back up that all important asset...data. This server represents the leading edge in high availability.

Part Number

17RYNxx

10K2330

10K2335

10K2337

20L0249

28L4454

37L7201

34L1501

37L6086

31H2Nxx

28L36xx

30RIxxx

03K8756

00N7990

03K9310

00N6xxx

37L0xxx

3L7205

28L4705

36L9701

Notes/Exchange-Stack

Description

Netfinity 8500R (PIII Xeon 700/1 MB 512 MB/Rack) (8U)

Netfinity 8500R 700 MHz/1 MB Upgrade with Pentium III Xeon Processor

Netfinity 4x Accelerator Filter

Netfinity Mezzanine Expansion Kit

Netfinity 512 MB SDRAM ECC RDIMM II

Netfinity 8500R Memory Expansion Card

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

Netfinity 10/100 Ethernet PCI Adapter 2

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

E54 Color Monitor 15” (13.8” Viewable Image Size), stealth black

Space Saver Keyboard

APC Smart-UPS 3000RMB

External Storage

NetMEDIA Storage Expansion Unit EL

40/80 GB DLT Internal SCSI Tape Drive

Netfinity 2M Ultra2 SCSI Cable

Netfinity EXP200 Storage Expansion Unit

Netfinity EXP200 350 W Redundant Power Supply

18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

Stack Options

8Ux28D Rack-to-Tower Kit

Netfinity NetBAY3E

Quantity

2

1

3

1

1

1

1

5

1

1

1

1

1

1

1

2

1

10

1

3

Usage

Power redundancy standard

Total of 6 SMP processors

Required for greater than 4 processors

Required for greater than 4 processors

Total of 2 GB of memory

Enables cache line interleaving

NOS Mirroring

-

NOS plus EXP200

-

-

-

External Tape Enclosure - Install in NetBAY3E

Installs in 03K8756

Tape to Onboard SCSI

Provides additional 10 Bays, 1 x 2M cable

-

RAID 5 with Hot-Spare in EXP200

-

3 x 3U enclosure for UPS, EXP200, Tape

107

Updated

17/10/00

Two Node High Availability Cluster

Public LAN

Server Node A

CH3

ServeRAID-3HB

(37L6086)

CH2 CH1

10/100 Ethernet (34L1501)

10/100 Ethernet (34L1501)

(2 m cable std.

(03K9311) on EXP200)

Netfinity EXP200

Ethernet Crossover

Cable

1

CH3 CH2 CH1

Server Node B

10/100 Ethernet (34L1501)

ServeRAID-3HB

(37L6086)

10/100 Ethernet (34L1501)

Public LAN

1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25 feet (7.6 m).

Part Number

18RYNxx

10K2166

10K2335

10K2337

20L0247

28L4454

34L1501

37L6086

37L7201

30RIxxx

03K8756

03K9311

00N7990

00N6xxx

37L0xxx

03K9311

37L7204

Two Node High Availability Cluster

Description

Server Nodes A & B

Netfinity 8500R (PIII Xeon 700/2 MB 512 MB/Rack) (8U)

Netfinity 8500R 700 MHz/2 MB Upgrade with Pentium III Xeon Processor

Netfinity 4X Accelerator Filter

Netfinity Mezzanine Expansion Kit

Netfinity 256 MB SDRAM ECC RDIMM II

Netfinity 8500R Memory Expansion Card

Netfinity 10/100 Ethernet Adapter 2

1

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

2

9.1 GB Ultra160 SCSI Hot-Swap SL HDD

APC Smart-UPS 3000RMB (3U)

External Storage

NetMEDIA Storage Expansion Unit EL (3U)

Netfinity 4.2 M Ultra2 SCSI Cable

3

40/80 GB DLT Internal SCSI Tape Drive

Netfinity EXP200 Storage Expansion Unit (3U)

2

Netfinity EXP200 350 W Redundant Power Supply

2

Netfinity 4.2 M Ultra2 SCSI Cable

2, 3

Quantity

2

16

2

4

2

10

2

2

4

2

1

2

1

1

1

1

10

Usage

Power redundancy standard

Total of 6 SMP processors per node

Required for greater than 4 processors

Required for greater than 4 processors

Total of over 2 GB of memory per node

Enables cache line interleaving

1 for crossover, 1 for public LAN/node

RAID controller - NOS plus EXP200

NOS mirroring

-

External Tape Drive Enclosure

03K8756 to onboard SCSI

Installs in 03K8756

Provides additional 10 bays

-

3-HB to EXP200

RAID 5 shared storage in EXP200

11AG1xx

28L36xx

9.1 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

Shared (or single occurrence) Resources

T54A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth black

Space Saver Keyboard

Rack Options

1

1

Mounts in keyboard tray

-

930842P

37L6888

28L4707

28L0542

Netfinity Enterprise Rack

Netfinity Flat Panel Monitor Rack-Mount Kit (3U)

Netfinity Rack Keyboard Tray

Netfinity Console Server Selector Switch (4-port)

1

1

1

1

-

Mounts in keyboard tray

-

-

94G7448

94G7447

Power Cable-Type C12

12 ft. Console Cable Set

4

2

-

-

94G6670 Blank Filler Panel Kit 1 -

1. Requires customer supplied Ethernet Crossover Cable which may vary in length up to a maximum of 25 feet (7.6 m).

2. By replicating this item, up to a total quantity of four ServeRAID-3HB Adapters (plus options) and eleven EXP200s can provide over 2 Terabytes of storage. Additional power and rack space will be required.

3. Cable length requirements are dependent on component placement within the rack or rack suite. To determine specific configuration requirements use the Netfinity Rack and/or Spreadsheet Configurators which can be downloaded from Web site www.pc.ibm.com/europe/configurators

Clustering is a group of interconnected computers used as a single, unified computing resource. Clustering Netfinity servers, like the IBM Netfinity 8500R, provides a high availability solution to keep you in touch with the key applications you need to run your business.

This sample configuration consists of paired IBM Netfinity 8500R cluster nodes equipped with eight-way SMP capability and redundant power supplies. Microsoft Cluster Service (MSCS) has been validated on

IBM Netfinity 8500R servers, using the Netfinity ServeRAID-3HB with the EXP200 Storage Expansion Unit. MSCS allows two configured servers, referred to as nodes, to be connected together to form a cluster. Providing system redundancy means that a complete server can fail and client access to server resources is largely unaffected. MSCS extends this theme by also allowing for software failures at an application level as well as an operating system level. If the operating system fails, all applications and services can be restarted on another server, and if just one application fails, it can be managed by MSCS individually. An additional independent network connection is used to perform monitoring within the cluster. One or more disk subsystems are attached to both nodes. In the above example, a Netfinity EXP200 was selected and the Netfinity ServeRAID-3HB Ultra2 SCSI Adapters provide the I/O control. Netfinity ServeRAID-3HB handles the “SCSI heartbeat” connection without the need for a dedicated SCSI connection and logically attaches the quorum disk, which allows arbitration when a failure occurs. Additional information on IBM Netfinity and IBM PC Server Clustering Solutions may be found on the World

Wide Web by accessing URL www.ibm.com/pc/us/netfinity/clustering.html.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

108

Updated

17/10/00

109

Updated

17/10/00

IBM Netfinity EXP200 Configurator

Netfinity EXP200 Hard Disk Drive Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

2

18.2 GB

(P/N 37L7202)

2

36.4 GB

(P/N 37L7203)

2

10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7204)

2

18.2 GB

(P/N 37L7205)

2

36.4 GB

(P/N 37L7206)

2

0 GB

9.1 GB

18.2 GB

27.3 GB

36.4 GB

45.5 GB

1

2

3

4

5

Standard on Base Models

-

1

-

2

-

-

-

-

1

5

6

1

2

3

4

Standard on Base Models

-

1

-

3

-

2

-

-

-

1

-

54.6 GB

63.7GB

72.8 GB

81.9GB

91 GB

109.2 GB

127.4GB

145.6GB

163.8GB

182GB

218.4GB

6

8

9

10

-

-

-

-

-

-

254.8GB -

3

7 -

4

-

5

6

7

10

-

-

-

-

2

-

-

3

-

8 4

9 -

5

6

7

-

-

8

9

10

-

-

-

-

-

4

-

5

6

7

8

9

10

-

-

-

-

3

-

-

2

291.2 GB

327.6 GB

-

-

-

-

8

9

-

-

-

-

8

9

364 GB (max) 10 10

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.

2. Ultra160 HDDs are limited to a maximum of Ultra2 bus speeds.

-

4

-

5

6

7

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

110

Updated

17/10/00

Bay Form

Factor

HS Odd #s

Even

#s

HS

Height

Netfinity EXP200

P/N 00N6xxx

HH

HH

Front

Access yes yes

On - 2 x 5 bay bus

Switch

Off - 1 x 10 bay bus

External: LVD or SE SCSI

Internal: LVD SCSI

Auto Termination

Usage open open

2 x 0.8mm VHDCI

Connectors

1. Housed in a 19” rack-mountable drawer and ships standard with a single power supply, power cord and 2 meter Ultra2 SCSI cable.

Requires IBM Netfinity Enterprise Rack (P/N 930842P) or

Expansion Cabinet (P/N 9308842X), Rack (P/N 9306900),

NetBAY22 (P/N 9306200), NetBAY3 (P/N 10L6912) or NetBAY3E

(P/N 36L9701).

External Storage Expansion Unit requires storage controllers and external cables. Select a supported controller from the system configurator and cables from Appendix D: Cables-Storage Units-

Controllers.

Bus

1

2

Part

Number

Description RPM Height Bays

Supported

Max.

Qty.

Ultra160 Hard Disk Drives (HDD)

1

37L7201

37L7202

9.1 GB Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB Ultra160 SCSI Hot-

Swap SL HDD

37L7203

37L7204

36.4 GB Ultra160 SCSI Hot-

Swap SL HDD

9.1 GB 10K-4 Ultra160

SCSI Hot-Swap SL HDD

37L7205 18.2 GB 10K-4 Ultra160

37L7206

19K0655

36.4 GB 10K-4 Ultra160

SCSI Hot-Swap SL HDD

9.1 GB 15K-rpm Ultra160

SCSI Hot-Swap HDD

19K0656

18.2 GB 15K-rpm Ultra160

SCSI Hot-Swap HDD

External Storage

Expansion Unit

7200

7200

7200

10,000

10,000

10,000

15,000

15,000

SL

SL

SL

SL

SL

SL

SL

SL

Form Factor

1...10

1...10

1...10

1...10

1...10

1...10

1...10

1...10

10

10

10

10

10

10

10

10

00N6xxx

37L5857

4

Netfinity EXP200 Storage

Expansion Unit

2, 3

Netfinity EXP200 Rack-to-

Tower Conversion Kit

Rack (3U)

-

37L0xxx

5

94G7448

Netfinity EXP200 350 W

Redundant Power Supply

3

Rack Power Cable Type C12

(3.7m)

3

-

-

1. Ultra160 HDDs are limited to a maximum of Ultra2 bus speeds.

2. Netfinity EXP200 Storage Expansion Unit ships with 10 half-high hot-swap bays which can be configured as a single bus, two independent buses or twintailed single bus. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350 W power supply. Optional hot-swap Netfinity EXP200 350W Power Supply (P/

N 37L0xxx) provides redundancy. To convert an EXP200 to a tower form factor, Netfinity EXP200 Rack-to-

Tower Conversion Kit (P/N 37L5857) is required.

3. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage

UPS or PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of power supplies.

4. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/

Spanish, 902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/

Italian, 907=South Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/

English:- Line Cords/ Publication Country Kits are included throughout.

5. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,

079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication

Kits are included throughout.

Limitations

Netfinity EXP200 hot-swapping of HDDs is restricted to a HDD that is inactive or where a lighted fault LED is indicated. The EXP200 is not supported when the SCSI channel of the SCSI adapter to which it is attached is split between internal devices and external devices. Each EXP200 must be attached to a dedicated SCSI channel of a supported SCSI adapter. The standard EXP200 configuration is supported as a rack drawer and is not currently supported for stacking directly on one another. It can be installed in a Netfinity NetBAY3 or NetBAY3E storage unit and stacked up to three units high, with a supported server on top. In addition, it can be converted to a tower with the addition of a Netfinity EXP200 Rack-to-Tower Conversion Kit (37L5857). See Appendix D:

Cables- Storage Units- Controllers for supported controllers and cables. A single two meter cable is included with the EXP200.

111

Updated

17/10/00

Cables and Controllers:

See Appendix D: Cables - Storage Units - Controllers

Sample Configurations

The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing

Representative for assistance with your specific configuration requirements.

Netfinity EXP200 One Independent SCSI Bus

To configure as a single 10 drive SCSI channel, attach one external cable from the SCSI adapter to either the 1 IN or 2 IN connectors in the EXP200. Set switch

1 to “Off” position.

External cable

(or)

SERVER

Server SCSI

Adapter

Order:

1 x 00N6xxx

1 x External Cable*

See Cables - Storage Units -

Controllers section

Up to 10 Disk Drives

19” Rack Space

* One 2M Ultra2 cable is included with each EXP200.

Netfinity EXP200 Two Independent SCSI Buses

To configure as two independent 5 drive SCSI channels, attach one external cable from the SCSI adapter to the SCSI bus 1 IN connector in the EXP200.

Attach a second External SCSI cable from another SCSI adapter, in the same or separate server, to the 2 IN connector in the unit. Set switch 1 to “On” position.

SERVER

Server SCSI

Adapter

Server SCSI

Adapter

Order:

1 x 00N6xxx

2 x External Cables*

See Cables - Storage Units -

Controllers section

Up to 10 Disk Drives

19” Rack Space

External cables

* One 2M Ultra2 cable is included with each EXP200.

Switch 1

Off

Standard Repeater Card

Operational mode (SCSI F/

W, Ultra SCSI, Ultra2 SCSI) may be limited by controller, cable or cable length. See

Appendix D for additional information.

Switch 1

On

Standard Repeater Card

Operational mode (SCSI F/

W, Ultra SCSI, Ultra-2

SCSI) may be limited by controller, cable or cable length, or hard disk drive type. See Appendix D for additional information.

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

Netfinity EXP200 One Independent SCSI Bus

High Availability Configuration

To configure a single 10 drive SCSI channel for clustering, attach one external cable from the SCSI adapter in Node A to the 1 IN connector in the EXP200.

Connect a second external cable to a SCSI adapter in Node B and to the 2 IN connector in the EXP200.

Node B

Server SCSI

Adapter

Node A

Server SCSI

Adapter

Order:

1 x 00N6xxx

2 x External Cables*

See Cables - Storage Units -

Controllers section

Up to 10 Disk Drives

19” Rack Space

* One 2M Ultra2 cable is included with each EXP200.

External cables

Switch1

Off

Standard Repeater Card

Operational mode (SCSI F/

W, Ultra SCSI, Ultra-2

SCSI) may be limited by controller, cable, or cable length. See Appendix D for additional information.

1 2 3 4 5 6 7 8 9 10

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

112

Updated

17/10/00

113

Updated

17/10/00

IBM EXP300 Configurator

Total Int.

Storage

1

7200RPM Hard Disk Drives (HDDs) 10,000RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L7201)

2

18.2 GB

(P/N 37L7202)

2

36.4 GB

(P/N 37L7203)

2

9.1 GB

(P/N 37L7204)

2

18.2 GB

(P/N 37L7205)

2

36.4 GB

(P/N 37L7206)

2

0 GB

18.2 GB

36.4 GB

54.6 GB

72.8 GB

91 GB

109.2 GB

127.4 GB

145.6GB

182 GB

218.4 GB

254.8 GB

291.2 GB

2

4

6

8

10

12

14

-

-

-

-

-

Standard on Base Models

1

2

3

4

5

6

7

8

10

12

14

-

-

1

-

-

-

2

3

4

5

6

7

8

2

4

6

8

10

12

14

-

-

-

-

-

Standard on Base Models

1

2

3

4

5

6

7

8

10

12

14

-

364.0 GB

436.8 GB

-

-

-

-

10

12

-

-

-

-

10

12

509.6 GB

(max.)

14 14

This table does not represent all possible hard drive configurations.

1. Select a total storage row then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.

2. When combined with a ServeRAID-4x controller, Ultra2 and Ultra160 HDD’s may be mixed on the same bus and operate up to their maximum respective speeds.

2

-

3

-

1

-

6

7

8

-

4

5

SCSI ID

0...6

8...14

Cable

Length

(Meters

2

Form

Factor

HS

HS

80

Height

SL

SL

Front

Access

Yes

Yes

Maximum MB/s

Ultra2 Controller

160

Usage open open

Ultra160

Controller

EXP300 Hard Disk Drive Configurator

4.2

80 160

1. The EXP300 ships with a single Ultra2 SCSI cable similar to Netfinity

2M Ultra2 SCSI Cable (P/N 03K9310).

Part

Number

Description RPM Height

37L7201

37L7202

37L7203

37L7204

37L7205

37L7206

19K0655

19K0656

Ultra 160 Hard Disk Drives

(HDD)

2

9.1 GB Wide Ultra2 SCSI Hot-Swap

SL HDD

18.2 GB Ultra160 SCSI Hot-Swap

SL HDD

36.4 GB Ultra160 SCSI Hot-Swap

SL HDD

9.1 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

18.2 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

36.4 GB 10K-4 Ultra160 SCSI Hot-

Swap SL HDD

9.1 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

18.2 GB 15K-rpm Ultra160 SCSI

Hot-Swap HDD

RPM

7200

7200

7200

10,000

10,000

10,000

15,000

15,000

Height

SL

SL

SL

SL

SL

SL

SL

SL

Bays

Supported

1

Bays

Supported

1...14

1...14

1...14

1...14

1...14

1...14

1...14

1...14

Max.

Qty.

14

3

14

3

14

3

14

3

14

3

14

3

14

3

14

3

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

114

Updated

17/10/00

115

Updated

17/10/00

EXP300

1

P/N 19K11xx

2 x 0.8mm VHDCI

Connectors

Selectable Bus Configuration

2 x 7 bays

1 x 14

2

bays

Ultra2 and/or Ultra160 HDDs

3

Auto Termination

SCSI IDs 0...6

SCSI IDs 8...14

External Storage Expansion

Unit

EXP300 Storage Expansion Unit

4, 5

Form

Factor

19K11xx

6

Rack (3U)

09N7296

EXP300 Rack-to-Tower Conversion

Kit

-

94G7448

Rack Power Cable Type C12

(3.7m)

5

-

1. EXP300 Storage Expansion Unit ships with 14 slim-line hot-swap bays which can be configured as a single bus, two independent buses or a twintailed single bus.

2. When combined with a ServeRAID-4x controller, Ultra2 and Ultra160 HDDs may be mixed on the same bus and operate at up to their maximum respective speeds.

3.Twintailing reduces the maximum number of HDDs on a single bus to 13.

4. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies.

5. This unit does not include a Rack Power Cable P/N 94G7448 when shipped (for attachment to high voltage UPS or

PDU). A standard country power cord only is included. If required, order a Rack Power Cable.

6. Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/

English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication

Country Kits are included throughout.

1. Housed in a 19” rack mountable drawer and ships standard with redundant 500 W hot-swap power supplies, two power cords and a single 2M Ultra2 SCSI cable capable of supporting Ultra160 speeds.

2. Twintailing reduces the maximum number of HDDs on a single bus to 13.

3. When combined with a ServeRAID-4x controller, Ultra2 and

Ultra160 HDDs may be mixed on the same bus and operate at up to their maximum respective speeds.

Requires IBM Netfinity Enterprise Rack (930842P) or

Expansion Cabinet (930842X), Rack (9306900), NetBAY22

(9306200), NetBAY3 (10L6912), NetBAY3E (36L9701) or Rackto-Tower Conversion Kit (09N7296).

External Storage Expansion Units require storage controllers and external cables. Select a supported controller from the system configurator and cables from Appendix D: Cables-Storage Units-

Controllers.

Cables and Controllers:

See Appendix D: Cables - Storage Units - Controllers

EXP300 One Independent SCSI Bus

SERVER

ServeRAID

3x or 4x

Cable Group A

1

OR

Selectable Bus Configuration

1 x 14 bays

SCSI IDs 0...14

Order:

• 1 x P/N 19K11xx

• 1 x External Cable from Group A

1

• Up to 14 Ultra2 and/or Ultra160 HDDs

1. One 2 M Ultra2 cable is included with each EXP300. If a longer cable is desired, select one from cable group A.

EXP300 One Independent Twintail SCSI Bus

High Availability Configuration

To configure as one independent twintailed 13 bay SCSI bus, attach two external cables from two ServeRAID adapters, in the same or separate servers, to the two external ports of the EXP300. The EXP300 must be set for 1 x 14

2 bays.

SERVER

ServeRAID

3x or 4x

OR

SERVER

ServeRAID

3x or 4x

ServeRAID

3x or 4x

Cable Group A

1

Selectable Bus Configuration

1 x 14

2

bays

EXP300 Sample Configurations

EXP300 Two Independent SCSI Buses

To configure as two independent 7 bay SCSI buses, attach two external cables from two ServeRAID adapters, in the same or separate servers, to the two external ports of the EXP300. The EXP300 must be set for 2 x 7 bays.

SERVER

ServeRAID

3x or 4x

OR

SERVER

ServeRAID

3x or 4x

ServeRAID

3x or 4x

Cable Group A

1

Selectable Bus Configuration

2 x 7 bays

SCSI IDs 0...6

SCSI IDs 8...14

Order:

• 1 x P/N 19K11xx

• 2 x External Cables from Group A

1

• Up to 14 Ultra2 and/or Ultra160 HDDs

1. One 2 M Ultra2 cable is included with each EXP300. If a longer cable is desired, select one from cable droup A.

SCSI IDs 0...5, 8...14

Order:

• 1 x P/N 19K11xx

• 2 x External Cables from Group A

1

• Up to 13 Ultra2 and/or Ultra160 HDDs

1. One 2 M Ultra2 cable is included with each EXP300. If a longer cable is desired, select one from cable droup A.

2. Twintailing reduces the maximum number of HDDs on a single bus to 13.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

116

Updated

17/10/00

117

Updated

17/10/00

IBM FAStT200 (HA) Configurator

FAStT200 Storage Server - Hard Disk Drive Configurator

Total Internal

Storage

1

10,000 RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L6209)

18.2 GB

(P/N 37L6210 or

P/N 19K0652)

36.4 GB

(P/N 37L6211 or

P/N 19K0653)

0 GB

18.2 GB

36.4 GB

54.6 GB

72.8 GB

73.4 GB

91.0 GB

109.2 GB

145.6 GB

146.8 GB

182.0 GB

218.4 GB

220.2 GB

254.8 GB

291.2 GB

-

-

-

-

10 or

-

-

-

-

2 or

4 or

6 or

8 or

-

5

6 or

8 or

-

10 or

-

-

-

-

1

Standard on all Base Models

-

2 or

3

4 or

-

1

-

2

-

6

-

-

5

7

8

-

3

4

293.6 GB

327.6 GB

364.0 GB

367.0 GB

440.4 GB

513.8 GB

-

-

-

-

-

-

-

-

-

-

-

-

-

9

10

-

-

-

587.2GB

660.6 GB

-

-

-

-

-

-

734.0 GB (max) -

This table does not represent all valid hard drive configurations.

1. Select a total storage row and then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +- 0.2 GB unless otherwise noted.

73.4 GB

(P/N 19K0654)

Part

Number

Description

37L6209 9.1 GB 10K-3 FC Hot-Swap HDD

37L6210 18.2 GB 10K-3 FC Hot-Swap HDD

37L6211 36.4 GB 10K-3 FC Hot-Swap HDD

19K0652 18.2 GB 10K-4 FC Hot-Swap HDD

19K0653 36.4 GB 10K-4 FC Hot-Swap HDD

19K0654 73.4GB 10K-4 FC Hot-Swap HDD

RPM

10,000

10,000

10,000

10,000

10,000

10,000

Height

SL

SL

HH

SL

SL

HH

Bays

Supported

1...10

1...10

1...10

1...10

1...10

1...10

Max. Qty

Supported

10

10

10

10

10

10

External Storage Expansion Unit

19K11xx

4

19K11xx

5

FAStT200 Storage Server

1,2,3

FAStT200 HA Storage Server

1,2

19K1121 FAStT200 Redundant RAID Controller

3

94G7448 Rack Power Cable Type C12 (3.7m)

2

Form Factor

Rack (3U)

Rack (3U)

-

-

1. The FAStT200 Storage Server and HA Storage Server include two hot-swap, 350 W auto-ranging redundant power supplies.

2. These units do not include a Rack Power Cable P/N 94G7448 when shipped (for attachment to high voltage UPS or PDU). A standard country power cord only is included. If required, order a Rack Power Cable.

3. Can be upgraded to a FAStT200 HA Storage Server through the addition of a FAStT200 Redundant RAID Controler P/N 19K1121.

4. Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German,

28=Denmark/English, 29=Israel/English, 30=Italy/English, 31=South Africa/English, 32=Switzerland/English, 34=Switzerland/German,

36=UK/English. Country/Language - Line Cords/Publications are included as indicated

5. Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German,

42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South Africa/English, 46=Switzerland/English, 48=Switzerland/German,

50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

5

6

7

4

-

-

8

9

10

-

3

2

-

-

-

-

-

-

-

-

1

-

-

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

118

Updated

17/10/00

119

Updated

17/10/00

IBM FAStT200 Storage Server P/N 19K11xx

1,2,3,5

IBM FAStT200 HA Storage Server P/N 19K11xx

1,2,4,5

Fibre Channel

Connectors

6

IN OUT

External: Fibre Channel

Internal: Fibre Channel

Auto Termination

Loop A

OUT IN

Loop B

1. Housed in a 19" Rack mountable drawer and ships standard with redundant power supplies and two standard country power cables requiring separate power sources. Requires IBM industry standard 19" rack, EIA-310D, with a minimum depth of 24"

(711.2 mm) or NetBAY3/3E.

Note: External Storage Expansion Units require storage controllers and external cables. Select a supported controller from the system configurator and cables from Appendix D: Cables-Storage-Units-Controllers.

2. The FAStT200 Storage Server includes a single loop only. The second loop (shown in the diagram) is available with the addition of a FAStT200 Redundant RAID Controller P/N 19K1121. This configuration then becomes equivalent to the

FAStT200 HA Storage Server.

3. Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/

German, 28=Denmark/English, 29=Israel/English, 30=Italy/English, 31=South Africa/English, 32=Switzerland/English,

34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated.

4. Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/

German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South Africa/English, 46=Switzerland/English,

48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

5. This unit does not include a Rack Power Cable P/N 94G7448 when shipped (for attachment to high voltage UPS or PDU).

A standard country power cord only is included. If required, order a Rack Power Cable.

6. GBICs are not included. Either Fibre Channel Long or Short-Wave GBICs (P/N 03K9307 or 03K9308 respectively) may be used.

IBM FAStT EXP500 Configurator

FAStT EXP500 Storage Expansion Unit - Hard Disk Drive Configurator

Total Internal

Storage

1

10,000 RPM Hard Disk Drives (HDDs)

9.1 GB

(P/N 37L6209)

18.2 GB

(P/N 37L6210 or

P/N 19K0652)

36.4 GB

(P/N 37L6211 or

P/N 19K0653)

0 GB

18.2 GB

36.4 GB

54.6 GB

72.8 GB

73.4 GB

91.0 GB

109.2 GB

145.6 GB

146.8 GB

182.0 GB

218.4 GB

220.2 GB

254.8 GB

291.2 GB

-

-

-

-

10 or

-

-

-

-

2 or

4 or

6 or

8 or

-

5

6 or

8 or

-

10 or

-

-

-

-

1

Standard on all Base Models

-

2 or

3

4 or

-

1

-

2

-

6

-

-

5

7

8

-

3

4

293.6 GB

327.6 GB

364.0 GB

367.0 GB

440.4 GB

513.8 GB

-

-

-

-

-

-

-

-

-

-

-

-

-

9

10

-

-

-

587.2GB

660.6 GB

-

-

-

-

-

-

734.0 GB (max) -

This table does not represent all valid hard drive configurations.

1. Select a total storage row and then select the quantity of HDDs from a column corresponding to the hard disk drive of choice. Total Internal Storage listed is within +- 0.2 GB unless otherwise noted.

73.4 GB

(P/N 19K0654)

Part

Number

Description

37L6209 9.1 GB 10K-3 FC Hot-Swap HDD

37L6210 18.2 GB 10K-3 FC Hot-Swap HDD

37L6211 36.4 GB 10K-3 FC Hot-Swap HDD

19K0652 18.2 GB 10K-4 FC Hot-Swap HDD

19K0653 36.4 GB 10K-4 FC Hot-Swap HDD

19K0654 73.4GB 10K-4 FC Hot-Swap HDD

RPM

10,000

10,000

10,000

10,000

10,000

10,000

Height

SL

SL

HH

SL

SL

HH

Bays

Supported

1...10

1...10

1...10

1...10

1...10

1...10

Max. Qty

Supported

10

10

10

10

10

10

External Storage Expansion Unit

00N71xx

3

FAStT EXP500 Storage Expansion Unit

1,2

94G7448 Rack Power Cable Type C12 (3.7m)

2

Form Factor

Rack (3U)

-

1. The FAStT EXP500 Storage Expansion Unit includes two hot-swap, 350 W auto-ranging redundant power supplies.

2. This unit does not include a Rack Power Cable P/N 94G7448 when shipped (for attachment to high voltage UPS or PDU). A standard country power cord only is included. If required, order a Rack Power Cable.

3. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English, 42=Israel/English,

43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/Language Line Cords/Publications are included as indicated.

5

6

7

4

-

-

8

9

10

-

3

2

-

-

-

-

-

-

-

-

1

-

-

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

120

Updated

17/10/00

121

Updated

17/10/00

IBM FAStT EXP500 Storage Expansion Unit

1

P/N 00N71xx

3,4

Fibre Channel

Connectors

2

IN OUT Switch

External: Fibre Channel

Internal: Fibre Channel

Auto Termination

Loop A

OUT IN

Loop B

1. Housed in a 19" Rack mountable drawer and ships standard with redundant power supplies and two standard country power cables requiring separate power sources. Requires IBM industry standard 19" rack, EIA-310D, with a minimum depth of 24"

(711.2 mm) or NetBAY3/3E.

Note: External Storage Expansion Units require storage controllers and external cables. Select a supported controller from the system configurator and cables from Appendix D: Cables-Storage-Units-Controllers.

2. GBICs are not included. Either Fibre Channel Long or Short-Wave GBICs (P/N 03K9307 or 03K9308 respectively) may be used.

3. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,

42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/Language

Line Cords/Publications are included as indicated.

4. This unit does not include a Rack Power Cable P/N 94G7448 when shipped (for attachment to high voltage UPS or PDU).

Fibre Array Solutions

Fibre Interconnection Guidelines

00N6881

00N6882

01K7296

19K1121

2108R3S

2109S08

2109S16

SFCU1xx

3

FAStT Host Adapter

FAStT500 Mini Hub

FC Failsafe RAID Controller

FAStT200 Redundant RAID Controller

SAN Data Gateway Router

SAN FC Switch, 8-Port

SAN FC Switch, 16-Port

FC RAID Controller Unit

-

-

-

S

S

S

S

S

-

E

-

-

-

E

E

-

S

-

-

-

-

S

S

H

S

E

-

E

E

-

-

-

S

-

-

-

-

S

S

-

S

E

S

E

S

E

E

S

S

E

S

E

S

E

E

S

S

-

H

-

-

E

E

-

35L1647

19K11xx

5

19K11xx

6

00N69xx

2

00N71xx

4

03K9307

03K9308

SAN FC Managed Hub

FAStT200 Storage Server

FAStT200 HA Storage Server

FAStT500 Storage Server

FAStT EXP500 Storage Expansion Unit

FC Long-Wave GBIC

FC Short-Wave GBIC

S

S

S

-

-

-

-

E

-

-

H

E

H

H

S

-

-

-

-

-

-

E

H

-

-

E

H

H

S

-

-

-

-

-

-

-

E

E

E

-

H

H

-

E

E

E

-

H

H

E

-

-

-

-

H

H

E

E

E

E

-

H

H

S Short-wave connection only. See Fibre Device Ports Reference section for GBIC/Integrated port information.

L Long-wave connection only. See Fibre Device Ports Reference section for GBIC/Integrated port information

E Either Short-wave or Long-wave connections allowed. See Fibre Device Ports Reference section for GBIC/Integrated pinformation.

H Hardware connection. One of these devices installs directly into the other. i.e.: The FAStT500 Mini Hub (P/N 00N6882) installs directly into the FAStT500 Storage Server

(P/N 00N69xx

5

) to provide GBIC availability

S

E

S

-

-

-

S

-

S

-

-

H

-

E

E

-

E

-

-

-

E

H

H

S

-

-

-

-

-

E

E

-

E

-

-

E

H

H

S

H

-

-

-

E

E

-

E

-

-

-

E

H

H

1. This device requires the use of GBICs. Purchase of GBICs may be needed in order to make connections to this device. See the Fibre Device Ports Reference section for

GBIC/Integrated port information.

2. Where ‘xx’ represents a country specific code as follows:- 13=US/English, 14=Euro/English, 18=Denmark/English, 19=Israel/English, 20=Italy/English, 21=South Africa/English, 22=Switzerland/

English, 26=UK/English. Country/Language - Line Cords/Publications are included as indicated

3.

Where ’xx’ = country publication and power cord codes as follows:- UK=United Kingdom and Arabia, DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, SE=Switzerland/

English, EU=countries not covered previously.

4. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English, 42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/

English, 49=UK/English. Country/Language - Line Cords/Publications are included as indicated

5. Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish, 27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English,

31=South Africa/English, 32=Switzerland/English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated

6. Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish, 41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English,

45=South Africa/English, 46=Switzerland/English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.

E

H

H

-

E

E

E

E

-

-

E

-

-

-

E

123

Updated

17/10/00

Fibre Device Ports Reference

Part

Number

Description Total

Connections

Possible

Integrated

Ports

Mini Hubs

Possible

Mini Hubs

Installed

GBIC

Ports

00N6881

00N6882

01K7296

03K9307

03K9308

19K1121

2108R3S

2109S08

2109S16

SFCU1xx

35L1647

FAStT Host Adapter

FAStT500 Mini Hub

1

FC Failsafe RAID Controller

FC Long-Wave GBIC

FC Short-Wave GBIC

FAStT200 Redundant RAID Controller

SAN Data Gateway Router

2

SAN FC Switch, 8-Port

SAN FC Switch, 16-Port

FC RAID Controller Unit

SAN FC Managed Hub

1

2

1

1

1

2

1

8

16

1

8

1

-

1

1

1

-

-

1

1

-

7

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

19K11xx

19K11xx

00N69xx

FAStT200 Storage Server

FAStT200 HA Storage Server

FAStT500 Storage Server

2

4

16

4

-

-

-

-

-

8

-

-

4

00N71xx FAStT EXP500 Storage Expansion Unit 5 -

1. Each FAStT500 Mini Hub provides two GBIC ports.

2. Single-ended SCSI.

3. Included GBICs and integrated optical ports are short-wave.

4. FAStT500 Storage Server supports up to eight non-redundant or four redundant host connections and up to eight non-redundant or four redundant storage

connections.

4

2

4

8

1

-

8

16

-

1

-

2

-

-

-

2

Supported Cable Groups

Cable Group A (0.8 mm to 0.8 mm)

03K9310

03K9311

Netfinity 2 M Ultra2 SCSI Cable

Netfinity 4.2 M Ultra2 SCSI Cable

37L7101 Netfinity 20 M Ultra2 SCSI Cable

Cable Group D (Short-Wave Fibre)

36L9973

03K9306

03K9305

Netfinity Fibre Channel 1 M Cable

Netfinity Fibre Channel 5 M Cable

Netfinity Fibre Channel 25 M Cable

Customer supplied short-wave cable of up to 500 meters

(0.31 miles)

Cable Group E (Long-Wave Fibre)

Customer supplied long-wave cable of up to 10 kilometers

(6.2 miles)

GBIC

03K9308

03K9307

Netfinity Fibre Channel Short-Wave

GBIC

1

Netfinity Fibre Channel Long-Wave

GBIC

1. Four Netfinity Fibre Channel Short-Wave GBIC’s (P/N 03K9308) are included with SAN Fibre Channel Switches (P/Ns 2109508 and

2109516).

GBICs

Included

-

-

-

-

-

-

4

3

4

3

-

-

-

-

-

-

-

FAStT Host Adapter

P/N 00N6881

Netfinity FAStT

Host Adapte

• PCI to FCAL 64/32-bit host adapter.

• Supported Attachments (use cable group D):

FAStT500 Storage Server

• Integrated short-wave optical port. No GBICs required.

•Full Fibre Channel Fabric support.

FAStT500 Storage Server

P/N 00N69xx

Mini Hub Mini Hub

Expansion Bays for

Additional Mini Hubs

GBIC Ports

GBIC Ports

FAStT500 Mini Hub

P/N 00N6882

GBIC Ports

GBIC

• Provides additional connections to the Netfinity FAStT500 Storage

Server - supports complex clustering or advanced storage applications.

• All connections to FAStT500 Mini Hubs require the use of GBICs.

GBICs are not included.

FAStT200 Storage Server P/N 19K11xx

GBIC Port

10/100 Ethernet Port RS-232

Power Supplies

• Dual high-performance, RAID controller cards-supports up to 100 MB/sec data transfer rate per controller.

• Two 175 W auto-ranging, hot-swap, redundant power supplies.

• Attach directly to FAStT Host Adapter(s) (P/N 00N6881) with shortwave cables and GBICs or indirectly through SAN Fibre Channel Managed Hub

(P/N 35L1647) using cables from cable group D or E with corresponding

GBICs.

• Height is 4U (1 U = 1.75 in. or 44.45 mm)

• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity Rack,

Netfinity NetBAY22 or 19-inch EIA-D Industry-Standard Rack. Mounting rails are included with the controller.

• For optimum performance no more than two FAStT500 Storage Servers

(P/N 00N69xx) should be attached to a single hub (P/N 35L1647)

• Includes four FAStT500 Mini Hubs (P/N 00N6882), two for host and two for storage.

• FAStT500 256 MB Cache (P/N 00N6883) expansion is required in installations where a large number of devices are supported.

• All connections to FAStT500 Mini Hubs require the use of GBICs. GBICs not included.

Fibre Channel RAID Controller Unit

P//N SFCU1xx)

Standard Fibre Channel RAID

Controller

Netfinity Fibre Channel Failsafe

RAID Controller Opt. (P/N

01K7296)

Hot-swap Fan

Hot-swap Power GBIC Port

Hot-swap Fan

Supplies

• Contains a single hot-plug, RAID controller which provides a single host

Fibre Channel arbitrated loop and a single storage Fibre Channel arbitrated loop.

• Can be upgraded to a FAStT200 HA Storage Server through the addition of a FAStT200 Redundant RAID Controller (P/N 19K1121).

• Integrated 10/100 Mbps Ethernet connector and RS-232 service support port.

• Performance optimised for 30 disk drives - supports optional FAStT

EXP500 Storage Expansion Units (P/N 00N71xx).

• Two hot-swap 350 W auto-ranging, redundant power supplies.

• Redundant fans - two hot-swap, dual-fan units.

• LED indicators on all critical components warn of faults, over temperature, and other abnormalities.

• Ten drive bays - supports slim-high or half-high Fibre Channel hot-swap hard disk drives.

• Height is 3U (1U= 1.75 in or 44.45 mm.

•Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity Rack,

Netfinity NetBAY22 or 19-inch EIA-D industry standard rack. Mounting rails are included with the controller.

• Support long- and short-wave connections. Requires optional GBICs for each connection. GBICs not included.

FAStT200 HA Storage Server P/N 19K11xx

GBIC Port 10/100 Ethernet Port

RS-232

• Contains a single Short-Wave Fibre Connection (use cable group D) and six female 0.8 mm Very High Density Connection Interface (VHDCI) SCSI connectors

• Hot-Swap Redundant Fans and Power Supplies

• Optional Netfinity Fibre Channel Failsafe RAID Controller (P/N 01K7296) provides a redundant RAID controller and second Short-Wave Fibre Connection

(use cable group D)

• Attach directly to FAStT Host Adapter(s) (P/N 00N6881) or indirectly through

SAN Fibre Channel Managed Hub (P/N 35L1647) using cables from cable group

D.

• Height is 4 U (1 U=1.75 in. or 44.45 mm)

• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity Rack,

Netfinity NetBAY22 or 19-inch EIA-D Industry-Standard Rack. Mounting rails are included with the controller.

• For optimum performance no more than two RAID controller units

P/N SFCU1xx should be attached to a single hub

Hot-swap Fan

Hot-swap Power GBIC Port

Hot-swap Fan

• Contains two hot-plug, RAID controllers. Each controller provides a single host Fibre Channel arbitrated loop and a single storage Fibre

Channel arbitrated loop.

• Integrated 10/100 Mbps Ethernet connector and RS-232 service support port.

• Performance optimised for 30 disk drives- supports optional FAStT

EXP500 Storage Expansion Units (P/N 00N71xx).

• Two hot-swap 350 W auto-ranging, redundant power supplies.

• Redundant fans - two hot-swap, dual-fan units.

• LED indicators on all critical components warn of faults, over temperature, and other abnormalities.

• Ten drive bays - supports slim-high or half-high Fibre Channel hot-swap hard disk drives.

• Height is 3U (1U= 1.75 in or 44.45 mm.

•Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity Rack,

Netfinity NetBAY22 or 19-inch EIA-D industry standard rack. Mounting rails are included with the controller.

• Support long- and short-wave connections. Requires optional GBICs for each connection. GBICs not included.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

124

Updated

17/10/00

125

Updated

17/10/00

FAStT EXP500 Storage Expansion Unit

P/N 00N71xx

GBIC Ports

Hot-swap

Fan

Hot-swap

Power Supplies

Hot-swap

Fan

• Two hot-swap, 350 W auto-ranging, redundant power supplies.

• Redundant fans - two hot-swap, dual-fan units.

• LED indicators on all critical components warn of faults, over temperature, and other abnormalities.

• Ten drive bays - supports slim-high or half-high Fibre Channel hotswap hard disk drives.

• Height is 3U (1 U = 1,75 in. or 44.45 mm)

• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity

Rack, Netfinity NetBAY22 or 19-inch EIA-D Industry-Standard

Rack. Mounting rails are included with the controller.

• Requires optional GBICs for each connection. GBICs not included.

EXP300 Storage Expansion Unit P/N 19K11xx

SCSI Connectors

Hot-swap Power Supplies with

Integrated Fan

• Fourteen slim-high drive bays.

• Supports Ultra160 SCSI data transfer speeds - up to 160 MB/s.

• Single or dual SCSI bus configurations.

• Dual hot-swap 500 W redundant power supplies with integrated

fan assemblies.

• Height is 3 U (1 U=1.75 in. or 44.45 mm).

• Tower capability through optional Rack-to-Tower Conversion Kit.

• Requires Netfinity Enterprise Rack or Expansion Cabinet,

Netfinity Rack, Netfinity NetBAY22 or 19-inch EIA-D

Industry-Standard Rack. Mounting rails are included with

the controller.

SAN Fibre Channel Switch, 8 or 16 Ports

P/Ns 2109S08, 2109S16

8 port switch

GBIC Ports with GBICs GBIC Ports

16 port switch

GBIC Ports with GBICs

GBIC Ports

P/N 2019S08

P/N 2019S16

GBIC Ports with GBICs

GBIC Ports

• Each port delivers up to 100 MB/sec, full-duplex data transfer.

• Comes with 4 Short-Wave GBICs installed.

• Embedded Web browser configuration, management and

service.

• Support for Public Fibre Channel Arbitrated Loops.

• Optional power supply (P/N 09L5403) available.

• The 8 port switch is 1 U (1 U=1.75 in. or 44.45 mm) high and

the 16 port switch is 2 U (1 U=1.75 in. or 44,45 mm) high.

SAN Fibre Channel Managed Hub

P/N 35L1647

Serial Port 10/100 Ethernet Port

Power

Integrated Short-Wave

Optical Ports

GBIC Port

• High-speed performance utilising nonblocking switch-based technology.

• Simultaneous 100 MB/sec full duplex data transfers across all ports.

• Eight ports, one that is configurable with either a short-wave or longwave optical GBIC.

• Support for industry standard MIBs enabling standard SNMP management.

• Height is 1 U (1 U=1.75 in. or 44.45 mm) high.

Fibre / Fibre Configuration Examples

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing

Representative for assistance with your specific configuration requirements.

Fibre Channel

Adapter

1

(D)

FAStT500 Storage Server

(P/N 00N69xx)

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

(D)

(D)

FAStT500 Storage Server

(P/N 00N69xx)

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

(D)

(D)

(D)

Switch/Hub

(D or E)

Switch/Hub

Switch/Hub

(D or E)

Switch/Hub

(D or E)

(D)

FAStT500 Storage Server

(P/N 00N69xx)

FAStT500 Storage Server

(P/N 00N69xx)

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

(D)

Switch/Hub

(D or E)

FAStT500 Storage Server

(P/N 00N69xx)

Shaded boxes represent separate hosts.

1. FAStT Host Adapter (P/N 00N6881) supports shortwave connections only.

P = Primary path, S = Secondary/Redundant path

All storage connections require a secondary/redundant pathway in order to function properly.

(D), (E) = Cable Groups used, refer to chart on earlier page in this section for more information

P

FAStT EXP500

(D or E)

P

FAStT EXP500

(D or E)

P

FAStT EXP500

(D or E)

FAStT EXP500

P

P

FAStT EXP500

(D or E)

P

P

FAStT EXP500

FAStT EXP500

P

FAStT EXP500

(D or E)

S

S

S

S

S

S

S

S

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

126

Updated

17/10/00

127

Updated

17/10/00

Fibre / SCSI Configuration Examples

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing

Representative for assistance with your specific configuration requirements.

Fibre Channel

Adapter

1

(D)

RAID Unit (P/N SFCU1xx)

Std. RAID Controller

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

(D)

(D)

RAID Unit (P/N SFCU1xx)

Std. RAID Controller Opt. Failsafe

Controller

Fibre Channel

Adapter

1

(D)

(D)

(D or E)

RAID Unit (P/N SFCU1xx)

Std. RAID Controller

Switch/Hub

Switch/Hub

RAID Unit (P/N SFCU1xx)

Std. RAID Controller

Fibre Channel

Adapter

1

(D)

Switch/Hub (D or E)

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

(D or E)

(D)

Switch/Hub

(D or E)

RAID Unit (P/N SFCU1xx)

Std. RAID Controller Opt. Failsafe

Controller

Fibre Channel

Adapter

1

Fibre Channel

Adapter

1

(D)

Switch/Hub

Shaded boxes represent separate hosts.

1. Configured as two independent 5 HDD buses.

(D), (E) = Cable Groups used, refer to chart on earlier page in this section for more information

(A)

EXP200

(A)

EXP200

(A)

EXP200

(A)

EXP200

(A)

EXP200

IBM Netfinity Fibre Array Solutions

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM

Marketing Representative for assistance with your specific configuration requirements

High-speed single-node Netfinity Fibre Channel Storage configuration offering performance, bandwidth & capacity

Netfinity Rack (P/N 9306900)

Tape Library Support

Netfinity Rack (P/N 9306900)

Monitor Compartment

(P/N 94G7444)

E74 Monitor

(P/N T32N3xx) (10U)

Four Port Console Selector Switch

(P/N 28L0542)

Keyboard Tray (P/N 28L4707) (2U)

Space Saver Keyboard

(P/N 28L36xx)

Short Wave

Fibre Cable

(Cable Group D)

Short Wave GBIC

(P/N 03K9308

Netfinity FAStT500 Storage

Server (P/N 00N69xx)

- Height (4U)

- Includes 19" Rack Installation

Hardware

Cable Selection

EXP500 - Cable Group D

Other Components

(Quantities will vary based on specific configurations)

FAStT Host Adapter

(P/N 00N6881)

EXP500 Storage Expansion Unit

(P/N 00N71xx)

- Height (3U)

- Up to 10 HDDs

- Cable Group D

(Up to 22 per FAStT500 Storage

Server P/N 00N69xx. Above 11 requires additional Mini Hubs to be installed in the Storage Server).

Server Node A

APC Smart-UPS 1400RMB

(P/N 14RIxxx) (3U)

Short Wave

Fibre Cable

(Cable Group D)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

Connector Types

68-pin - High Density Connector

0.8 mm - Very High Density Connection Interface VHDCI

Cable Group A (0.8 mm to 0.8 mm)

03K9310 - Netfinity 2 M Ultra2 SCSI Cable

03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable

37L7101- Netfinity 20 M Ultra2 SCSI Cable

Cable Group D (Short-Wave Fibre)

36L9973 - Netfinity Fibre Channel 1 M Cable

03K9306 - Netfinity Fibre Channel 5 M Cable

03K9305 - Netfinity Fibre Channel 25 M Cable

Customer supplied short-wave cable of up to 500 meters (0.31 miles)

Cable Group E (Long-Wave Fibre)

Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)

GBIC

03K9308 - Netfinity Fibre Channel Short-Wave GBIC

1

03K9307 - Netfinity Fibre Channel Long-Wave GBIC

1. Four Netfinity Fibre channel Short-Wave GBIC’s (P/N 03K9308)

are included with SAN Fibre Channel Managed Hub (P/N 35L1647)

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

128

Updated

17/10/00

129

Updated

17/10/00

IBM Netfinity Fibre Array Solutions

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements

High-speed single-node Netfinity Fibre Channel Storage configuration with Microsoft NT failover support and RAID redundancy for availability, performance, capacity

Netfinity Rack (P/N 9306900)

Monitor Compartment

(P/N 94G7444)

E74 Monitor

(P/N T32N3xx) (10U)

Four Port Console Selector Switch

(P/N 28L0542)

Keyboard Tray (P/N 28L4707) (2U)

Space Saver Keyboard

(P/N 28L36xx)

Short Wave

Fibre Cable

(Cable Group D)

Netfinity Rack (P/N 9306900)

Tape Library Support

Short Wave GBIC

(P/N 03K9308

Netfinity FAStT500 Storage

Server (P/N 00N69xx)

- Height (4U)

- Includes 19" Rack Installation

Hardware

Cable Selection

EXP500 - Cable Group D

Other Components

(Quantities will vary based on specific configurations)

Rack

- Blank Filler Kits (P/N 94G6670)

- Power Cable (P/N 94G7448)

- Console Cable (P/N 94G7447)

- Side Panel Kit (P/N 94G6669)

- Rack Attachment Kit

(P/N 94G7446)

FAStT Host Adapter

(P/N 00N6881)

FAStT Host Adapter

(P/N 00N6881)

Server Node A

)

Netfinity EXP500 Storage

Expansion Unit (P/N 00N71xx)

- Height (3U)

- Up to 10 HDDs

- Cable Group D

(Up to 22 per FAStT500 Storage

Server P/N 00N69xx. Above 11 requires additional Mini Hubs to be installed in the Storage Server).

APC Smart-UPS 1400RMB

(P/N 14RIxxx) (3U)

Short Wave

Fibre Cable

(Cable Group D)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

Connector Types

68-pin - High Density Connector

0.8 mm - Very High Density Connection Interface VHDCI

Cable Group A (0.8 mm to 0.8 mm)

03K9310 - Netfinity 2 M Ultra2 SCSI Cable

03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable

37L7101 - Netfinity 20 M Ultra2 SCSI Cable

Cable Group D (Short-Wave Fibre)

36L9973 - Netfinity Fibre Channel 1 M Cable

03K9306 - Netfinity Fibre Channel 5 M Cable

03K9305 - Netfinity Fibre Channel 25 M Cable

Customer supplied short-wave cable of up to 500 meters (0.31 miles)

Cable Group E (Long-Wave Fibre)

Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)

GBIC

03K9308 - Netfinity Fibre Channel Short-Wave GBIC

03K9307 - Netfinity Fibre Channel Long-Wave GBIC

1. Four Netfinity Fibre channel Short-Wave GBIC’s (P/N 03K9308)

are included with SAN Fibre Channel Managed Hub (P/N 35L1647).

IBM Netfinity Fibre Array Solutions

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements

Cluster Solution

High speed multiple node Microsoft Cluster Service (MSCS) and Netfinity Fibre Channel Storage configuration offering data protection and RAID redundancy.

Public Lan

Netfinity Rack (P/N 9306900)

Monitor Compartment

(P/N 94G7444)

E74 Monitor

(P/N T32N3xx) (10U)

Four Port Console Selector Switch

(P/N 28L0542)

Keyboard Tray (P/N 28L4707) (2U)

Space Saver Keyboard

(P/N 28L36xx)

Short Wave

Fibre Cable

(Cable Group D)

Netfinity Rack (P/N 9306900)

Tape Library Support

Standard Fibre

Channel RAID

Controller

Netfinity Fibre Channel

Failsafe RAID Controller

(P/N 01K7296)

- SAN Fibre Channel Managed

Hub (P/N 35L1647).Qty. 1

- Height (1U)

25 ft. Ethernet

Crossover Cable

1

Onboard or

Supported LAN

Adapter

Netfinity 10/100

Ethernet Adapter

(P/N 34L1501)

FAStT Host

Adapter

(P/N 00N6881)

Onboard RAID or

ServeRAID-3x

(NOS Mirroring)

Cable Selection

EXP200 - Cable Group A

Mirrored Quorum Disks

Netfinity Fibre Channel RAID

Controller Unit (P/N SFCU1xx)

- Height (4U)

- Six 0.8 mm VHDCI

Female Connectors

- LVDS

- Includes 19" Rack Installation

Hardware

Server Node B

Netfinity 10/100

Ethernet Adapter

(P/N 34L1501)

FAStT Host

Adapter

(P/N 00N6881)

Supported Storage Expansion Units

In Any Combination

(Up to six per Controller

P/N SFCU1xx)

Netfinity EXP200 (P/N 00N6xxx)

- Height (3U)

- Up to 10 HDDs

- Two 0.8 mm VHDCI

Female Connectors

- Cable Group A

- Switch 1 "off"

Other Components

(Quantities may vary based on specific configurations)

Rack

- Blank Filler Kits (P/N 94G6670)

- Power Cable (P/N 94G7448)

- Console Cable (P/N 94G7447)

- Side Panel Kit (P/N 94G6669)

- Rack Attachment Kit

(P/N 94G7446)

Server

- Each server requires two

identical HDDs for NOS

mirroring

Onboard or

Supported LAN

Adapter

Onboard RAID or

ServeRAID-3x

(NOS Mirroring)

Server Node A

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

Connector Types

68-pin - High Density Connector

0.8 mm - Very High Density Connection Interface VHDCI

Cable Group A (0.8 mm to 0.8 mm)

03K9310 - Netfinity 2 M Ultra2 SCSI Cable

03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable

37L7101 - Netfinity 20 M Ultra2 SCSI Cable

Cable Group D (Short-Wave Fibre)

36L9973 - Netfinity Fibre Channel 1 M Cable

03K9306 - Netfinity Fibre Channel 5 M Cable

03K9305 - Netfinity Fibre Channel 25 M Cable

Customer supplied short-wave cable of up to 500 meters (0.31 miles)

Cable Group E (Long-Wave Fibre)

Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)

GBIC

03K9308 - Netfinity Fibre Channel Short-Wave GBIC

1

03K9307 - Netfinity Fibre Channel Long-Wave GBIC

1. Microsoft Cluster Server (MSCS) requires a private interconnect

between clustered nodes. A 25 ft. Ethernet crossover cable is

shown but not available from IBM as a separate option. Contact

your IBM Business Partner for assistance.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

130

Updated

17/10/00

131

Updated

17/10/00

IBM Netfinity Fibre Array Solutions

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements

Advanced high-speed high-availability multiple node Microsoft Cluster Service (MSCS) and fully redundant Netfinity Fibre

Channel Storage configuration offering the highest levels of data protection and availability and access to data

Public Lan

See Other Components-

Server

25 ft. Ethernet

Crossover

Cable

1

Netfinity Rack (P/N 9306900)

Monitor Compartment

(P/N 94G7444)

E74 Monitor

(P/N T32N3xx) (10U)

Four Port Console Selector Switch

(P/N 28L0542)

Keyboard Tray (P/N 28L4707) (2U)

Space Saver Keyboard

(P/N 28L36xx)

Netfinity 10/100

Ethernet PCI Adapter 2

(P/N 34L1501)

Onboard RAID or

ServeRAID-3x

(NOS Mirroring)

FAStT Host Adapter

(P/N 00N6881)

Server Node B

FAStT Host

Adapter

(P/N 00N6881)

Short Wave

Fibre Cable

(Cable Group D)

Netfinity Rack (P/N 9306900)

Tape Library Support

Standard Fibre

Channel RAID

Controller

Netfinity Fibre Channel

Failsafe RAID Controller

(P/N 01K7296)

Cable Selection

EXP200 - Cable Group A

Mirrored Quorum Disks

- SAN Fibre Channel Managed

Hub (P/N 35L1647).Qty. 2

- Height (1U)

Netfinity Fibre Channel RAID

Controller Unit (P/N SFCU1xx)

- Height (4U)

- Six 0.8 mm VHDCI

Female Connectors

- LVDS

- Includes 19" Rack Installation

Hardware

Supported Storage Expansion Units

In Any Combination

(Up to six per Controller

P/N SFCU1xx)

Netfinity EXP200 (P/N 00N6xxx)

- Height (3U)

- Up to 10 HDDs

- Two 0.8 mm VHDCI

Female Connectors

- Cable Group A

- Switch 1 "off"

Netfinity 10/100

Ethernet PCI Adapter 2

(P/N 34L1501)

FAStT Host Adapter

(P/N 00N6881)

Other Components

(Quantities may vary based on specific configurations)

Rack

- Blank Filler Kits (P/N 94G6670)

- Power Cable (P/N 94G7448)

- Console Cable (P/N 94G7447)

- Side Panel Kit (P/N 94G6669)

- Rack Attachment Kit

(P/N 94G7446)

Server

- Each server requires two

identical HDDs for NOS

mirroring

- Public LAN access through an

onboard or supported LAN

adapter

Onboard RAID or

ServeRAID-3x

(NOS Mirroring)

FAStT Host

Adapter

(P/N 00N6881)

Server Node A

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U))

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

APC Smart-UPS 3000RMB

(P/N 30RIxxx) (3U)

Connector Types

68-pin - High Density Connector

0.8 mm - Very High Density Connection Interface VHDCI

Cable Group A (0.8 mm to 0.8 mm)

03K9310 - Netfinity 2 M Ultra2 SCSI Cable

03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable

37L7101 - Netfinity 20 M Ultra2 SCSI Cable

Cable Group D (Short-Wave Fibre)

36L9973 - Netfinity Fibre Channel 1 M Cable

03K9306 - Netfinity Fibre Channel 5 M Cable

03K9305 - Netfinity Fibre Channel 25 M Cable

Customer supplied short-wave cable of up to 500 meters (0.31 miles)

Cable Group E (Long-Wave Fibre)

Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)

GBIC

03K9308 - Netfinity Fibre Channel Short-Wave GBIC

1

03K9307 - Netfinity Fibre Channel Long-Wave GBIC

1. Microsoft Cluster Server (MSCS) requires a private interconnect

between clustered nodes. A 25 ft. Ethernet crossover cable is

shown but not available from IBM as a separate option. Contact

your IBM Business Partner for assistance.

Netfinity Availability Extensions for NT 4.0

MSCS Four Node Cluster

Note: - The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Customer specific

MSCS configurations require IBM approval. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.

CISCO Ethernet LAN Switch

4

AdditionalPower Supply

(P/N 09L5403)

SAN Fibre Channel Switch(P/N 2109S08)

Cluster Interconnect

Node 1

Node 2

Node 3

Node 4

Node 1

Node 2

Node 3

Node 4

Onboard Advanced

System Management

Adapter

PCI Slot 7

Netfinity 10/100

Ethernet PCI Adapter 2

(P/N 34L1501)

PCI Slot 6

Netfinity 10/100

Ethernet PCI Adapter 2

(P/N 34L1501)

Memory: 2 x (P/N 20L0247)

1 x Expansion Card (P/N

28L4454

PCI Slot 4

Netfinity FAStTHost

Processors

7 X (P/N 10K2166),

1 X Kit (10K2337, PCI Slot 3

Adapter

(P/N 00N6881)

1 X Filter (10K2335)

Netfinity FAStTHost

Adapter

(P/N 00N6881)

PCI Slot 1

Mirrored Hot-Swap HDD

2 x P/N 37L7206

ServeRAID-3HB

Ultra2 SCSI Adapter

(P/N 36L6086)

Server Nodes 1... 4

Netfinity 8500R (P/N 18RYNxx)

Single Occurrence Options

(Any node 1...4)

PCI tape controller included with library

Rack B

Tape

FC Switch

FC Switch

EXP200

EXP200

EXP200

8500R

8500R

5000 UPS

5000 UPS

Public

LAN

AdditionalPower

Supply (P/N

09L5403)

Node 1

Node 2

Node 3

Node 4

RAID 5

Minimum 3 HDDs

plus

1 Hot-spare

IBM

Cable Group D

2

(Short-Wave

Fibre)

Mirrored

Quorum

Disks

SAN Fibre Channel Switch (P/N 2109S08)

Standard Fibre

Channel RAID

Controller

SAN Fibre Channel Switch

2109-S08- Qty. 2

- Height (2U)

-- Includes Four Short Wave

- GBICs per Switch

- Includes 19" Rack

Installation Hardware

- Optional Short Wave

GBICs (P/N 03K9308).

-Optional Additional Power

Supply (P/N 09L5403

Cable Group D

2

(Short-Wave Fibre)

Netfinity Fibre Channel

Failsafe RAID Controller

(P/N 01K7296)

Fibre Channel RAID

Controller Unit

(P/N SFCU1xx)

- Height (4U)

- Six 0.8 mm VHDCI

Female Connectors

- Ultra2 SCSI

- Includes 19" Rack

Installation Hardware

Cable Group A

2

Rack A

RAID Controller

EXP200

EXP200

EXP200

8500R

Flat Panel Monitor

Keyboard

Console Switch

8500R

5000 UPS

5000 UPS

Optional

DLT Tape Library

Netfinity EXP200

(P/N 00N6xxx)

- Height (3U)

- Up to 10 HDDs

(Example: 10 x 18.2 GB P/N

37L7205)

- Two 0.8 mm VHDCI Female

Connectors

- Up to six (>1 Terabyte) per

Controller P/N SFCU1xx

- Cable Group A

(Ultra2 0.8 - 0.8mm)

Connector Types

0.8 mm - Very High Density Connection Interface VHDCI

Cable Group A (0.8 mm to 0.8 mm)

03K9310 - Netfinity 2 M Ultra2 SCSI Cable

03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable

037L7101 - Netfinity 20 M Ultra2 SCSI Cable

Cable Group D (Short-Wave Fibre)

03K9306 - Netfinity Fibre Channel 5 M Cable

03K9305 - Netfinity Fibre Channel 25 M Cable

Customer supplied short-wave cable of up to 500 meters (0.31 miles)

.

GBIC

03K9308 - Netfinity Fibre Channel Short-Wave GBIC

1

03K9307 - Netfinity Fibre Channel Long-Wave GBIC

(1) Four Fibre Channel Short-Wave GBICs are included with SAN

Fibre Channel Switch P/N 2109S08

(2) Cable length requirements are dependant on component placement within the rack suite. The parts list for this example reflects requirements for the illustrated configuration only. Cable length requirements for other configurations are best determined by using the Netfinity Rack Configurator which is downloadable from

Web site www.ibm.com/pc/us/products/server/download.html

(3) A tape library is optional and attaches to any one of the nodes within the cluster.

(4) Please contact your NAE Specialist in Advanced Technical

Support about the most up-to-date Cluster interconnect requirements.

Additional Information and Configuration

Tools Available

See "Information Sources" section for Clustering, Server Paper

Configurator, ConfigXpert and Netfinity Rack Configurator URLs

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

132

Updated

17/10/00

133

Updated

17/10/00

Netfinity Availability Extensions for NT4.0

MSCS Four Node Cluster - Parts List

1

Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Customer specific MSCS configurations require IBM approval. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.

Part

Number

Description

18RYNxx Netfinity 8500R-700 MHz/2 Mb L2, 512k Mb RAM

10K2335 Netfinity 4x Accelerator Filter

10K2337 Netfinity Mezzanine Expansion Kit

10K2166

Netfinity 8500R 700 MHz/ 2 Mb Upgrade with Pentium III Xeon

Processor

37L7206 36.4 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD

36L6086 IBM Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

34L1501 Netfinity 10/100 Ethernet PCI Adapter 2

00N6881 Netfinity FAStT Host Adapter

37L0xxx Netfinity EXP200 350 W Redundant Power Supply II

20L0247 256 MB ECC SDRAM RDIMM II Memory

28L4454 Netfinity Memory Expansion Card

02K65xx UltraSlim 56 W AC Adapter

Storage Subsystems

Qty.

28 7 per node, total of 8 SMP processors per node

8

8

4

8

4

4

8

4

4

4

4

Cluster Nodes

Allows expansion to 8 SMP processors.

Usage

2 per node, mirrored NOS, attached to ServeRAID

1 per node for NOS HDDs. Install in PCI slot 1

Public LAN - slot 6/ interconnect slot 7

2 per node, each attaches to one of the two Fibre Hubs. Install in PCI slots 3 and 4.

1 per node, provides power supply redundancy for each node

2 per node to increase memory to 1GB

1 per node, to expand for additional memory

Provides an independent backup power source for systems management

2109S08 SAN Fibre Channel 8 Port Switch

09L5403 Additional Power Supply

03K9308 Netfinity Fibre Channel Short-Wave GBIC

SFCU1xx Netfinity Fibre Channel RAID Controller Unit

01K7296 Netfinity Fibre Channel Failsafe RAID Controller

00N6xxx Netfinity EXP200 Storage Expansion Unit

37L7206 Netfinity EXP 36,4 GB 10K-4 Ultra160 SCSI Hot-Swap HDD

37L7204 Netfinity EXP 9.1 GB 10K-4 Ultra160 SCSI Hot-Swap HDD

00N79xx DLT Tape Library

37L6862 APC Smart-UPS 5000RMB

2

Storage Cables

03K9306 Netfinity Fibre Channel 5 M Cable

03K9310 Netfinity 2 M Ultra2 SCSI Cable

03K9311 Netfinity 4.2 M Ultra2 SCSI Cable

-

-

Internet Components

CISCO Ethernet Switch

4

Standard CAT5 Cables

4

Other Non-Rack

Customer

Supplied

Ethernet System Management Cables

28L36xx Space Saver II Keyboard (1U)

11AG1xx Flat Panel Monitor

37L6888 Flat Panel Monitor Adapter

1

1

1

2

Redundant short-wave (SW) connections from each of four nodes to Netfinity Fibre

Channel RAID Controller Unit. Each switch includes four standard SW BBICs

Hot-Swap redundant power supply for SAN Fibre Channel Switch 2

10 8 for adapters and 2 for switches

1 Attaches to 6 EXP200s, with Failsafe Controller - two attachments to the hubs

1 Installs in Controller Unit, providesredundant path to EXP200s

6 One LVDS attachment to RAID Controller Unit per EXP200, max, of 60 HDDs

58 A minimum of four RAID 5 HDDs( 3 plus a hot-spare) with a maximum of 58

2

1

4

Mirrored Quorum HDDs

Tape subsystems are optional. The 3502R14 includes a 3 M cable and PCI controller

Power connections are intra-rack only

2

10 2 x 4 nodes to hub, 2 hub to RAID controllers

3

3

RAID controller to EXP200s

RAID controller to EXP200s

1

8

8

Standard configuration supports interconnection up to 4 nodes

2 per node for cluster interconnect/network access

Provides interconnection between Advanced System Management Adapters.

Includes TrackPoint

Rack / Related

930842P Netfinity Enterprise Rack

930842X Netfinity Enterprise Expansion Cabinet

28L4707 Netfinity Rack Keyboard Tray

28L0542 Netfinity Console Selector Switch (4-port)

1

1

1

1

Provides 42U of mounting space per rack

Provides 42U of additional mounting space

Allows keyboard 28L3640 to be stowed in a ready-to-use position

Connects 4 nodes to 4-port switch

94G7448 Power Cable - TypeC12

94G7447 NetBAY 12ft. Console Cable Set

Netfinity Availability Extensions for MSCS

3

36L9891 Netfinity Availability Extensions for MSCS (3 node)

5

36L9892 Netfinity Availabilty Extensions for MSCS (1 additional node)

5

1

1

15 Provides power cables for UPS attachment to installed components

4 Attaches each node to the console switch.

License for first 3 nodes

License for last additional node (4th)

1. Cable, power, cooling and weight are dependent on component placement within the rack and rack suite. This parts list reflects one possible configuration of the listed components. Prior to ordering, you should configure your specific environment using the Netfinity Rack Configurator. The Netfinity Rack Configurator is downloadable from URL: www.ibm.com/pc/us/products/server/download.html.

2. Pre-installation site planning information: P/N 34L6862 contains four L6-30P, 220V 30 amp circuitry.

3. Consists of Netfinity Availability Extensions for MSCS software licenses (support for up to four nodes) and installation services for the complete Netfinity solution being installed. Netfinity Availabilty

Extensions for MSCS is available through IBM Direct as a solution offering and is designed for installation by trained service personnel. Please contact your IBM representative for ordering information.

4. Please contact your IBM representative about the most up-to-date Cluster Interconnect requirements.

5. Netfinity Availability Extensions for MSCS(NAE) require NAE Service Pack 3.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

134

Updated

17/10/00

135

Updated

17/10/00

IBM Netfinity NetBAY3/NetBAY3E Stackable

Enclosur e

Sample

Configuration

Installation Guidelines:

1) Locate power units with line cords in the bottom enclosure.

2) Install components starting from the bottom; start with the heaviest device.

3) If nothing is installed in the enclosure, attach the rear blank panel for stability.

Netfinity 7600

Networking

EXP200

UPS

NetBAY3

19 in.

36 in.

914 mm

36 in.

6 in.

36 in.

914 mm

3.2 ft

2

19 in x 24 in.

483 mm x 610mm

26 in.

Service clearance

Front

6 in.

20 in.

152 mm

508 mm

Operational clearance

(1.7 ft.X 3 ft.= 5 ft.

2

)

(508 mm x 914 mm = 0.46 m

2

(7.6 ft. X 8.2 ft.= 62.3ft

2

)

)

(2316 mm x 2499 mm = 5.79 m

2

)

36 in.

914 mm

Netfinity 7600

1

Supported Devices

Servers

Netfinity 7100

Netfinity 7000-M10

2

Netfinity 5500

Netfinity 5500-Mxx

Netfinity 8500R

3

Expansion

4

Netfinity EXP200

Tape Units

4

NetMEDIA

Power

4

APC Smart-UPS 1400RMiB

APC Smart-UPS 3000RMiB

200-240V PDU

Networking

4

2210 Multiprotocol Router

8230 T-R Controlled Access Unit

8235 Dial-in Access to LANs

8237 Ethernet Hub

8238 Nways T-R Hub

8271 Ethernet Switch

8272 T-R Switch

8285 ATM Switch

NetBAY3

X

X

-

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

NetBAY3E

-

-

X

-

-

-

X

X

X

X

X

X

X

X

X

X

X

X

X

Size (U)

-

-

-

-

-

3

3

3

3

1

1, 2

2

1

2

2

2

2

3

Weight(lb/kg)

120/54.4

120/54.4

160/72.6

120/54.4

123.4/56.0

170/77.1

80/36

37/17

55/24.9

112/50.8

8/3.6

7/3.2, 20/9.1

15/6.8

8/3.6

10/4.5

11/5.0

16/7.3

16/7.3

70/31.8

Max/Enclosure n/a n/a n/a n/a n/a n/a

1

1

1

1

1

3, 1

1

3

1

1

1

1

1

Max/Stack

1

1

1

1

1

1

3

3

1

1

1

9, 3

3

9

3

3

3

3

3

1. Netfinity 7600 systems are rack mountable and ship without a keyboard or mouse. In order to be utilised with a NetBAY3 or in a tower configuration, optional 8Ux28D Rack-to-Tower Kit

(P/N 28L4705) must be installed.

2. Netfinity 7000-M10 systems are rack mountable and ship without a keyboard. In order to be utilized with a NetBAY3 or in a tower configuration, optional Rack-to-Tower Conversion Kit

(P/N 01K8005) must be installed.

3. Netfinity 8500R systems are rack mountable and ship without a keyboard. In order to be utilized with a NetBAY3E or in a tower configuration, optional Rack-to-Tower Kit (P/N 28L4705) must be installed.

4. NetBAY3 and NetBAY3E do not contain a top cover and therefore require a supported server as the top component in a stack

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

136

Updated

17/10/00

137

Updated

17/10/00

IBM Netfinity NetBAY3/3E Stackable Enclosure

Tower Models

Monitor/

Keyboard

1

Add Options

Single NetBay and Casters

Add Options

Max Configurations

Monitor/

Keyboard

1

Netfinity 5500,

5500 Mxx

Std. NetBAY3

2

Skid Pads

Monitor/

Keyboard

1

Netfinity 7100

Casters

(P/N 10L6913)

NetBAY3

(P/N 10L6912)

- and -

Casters

(P/N 10L6913)

Netfinity 5500,

5500 Mxx

Std. NetBAY3

Netfinity 7100

NetBAY3

Up to Two Additional

NetBAY3s

(P/N 10L6912)

Up to Two Additional

NetBAY3s

(P/N 10L6912)

Netfinity 5500,

5500 Mxx, 7100

5

,

7000 M10

NetBAY3

NetBAY3

NetBAY3

Caster Stabiliser

Monitor/

Keyboard

1

Glide Feet

Rack Models

Netfinity 7000

M10

Netfinity 7000 M10

Rack-to-Tower

Conversion Kit

2

(P/N 01K8005)

- and -

NetBAY3

(P/N 10L6912)

Netfinity 7000

M10

NetBAY3

Netfinity 5500,

5500 Mxx, 7100,

7600

Glide Feet

Monitor/

Keyboard

1

Netfinity 5500,

5500 Mxx

Netfinity 7100,

7600

Netfinity 8Ux24D

Rack-to-Tower Kit

3

(P/N 37L6860)

-OR-

Netfinity 5500,

5500 Mxx, 7100,

7600

Up to Two Additional

NetBAY3s

(P/N 10L6912)

Netfinity 5500,

5500 Mxx, 7100

5

,

7600

5

NetBAY3

NetBAY3

NetBAY3

NetBAY3

Caster Stabiliser

Monitor/

Keyboard

1

Netfinity 8500R

Netfinity 8500R

Netfinity 8Ux28D

Rack-to-Tower Kit

4

P/N (28L4705)

Up to Two Additional

NetBAY3Es

(P/N 36L9701)

Netfinity 8500R

5

NetBAY3E

NetBAY3E

NetBAY3E

NetBAY3E

1. Netfinity rack models ship without a keyboard or mouse. Those supported for stacking on a NetBAY3 or NetBAY3E must have a rack-to-tower kit installed.

2. Netfinity 7000 M10 Rack-to-Tower Conversion Kit P/N 01K8005 includes casters which can also be used with a NetBAY3.

3. Netfinity 8Ux24D Rack-to-Tower Kit P/N 37L6860 includes casters, caster stabiliser, glide feet and a single NetBAY3.

Either NetBAY3 or the glide feet may be utilised but not both.

4. Netfinity 8Ux28D Rack-to-Tower Kit (P/N 28L4705) includes casters, caster stabiliser, and a single NetBAY3E.

5. Netfinity 7100, 7600 and 8500R are not supported for installation with three empty NetBAY enclosures without a caster stabiliser. The caster stabiliser is included in Rack-to-Tower Kits P/N 37L6860 and P/N 28L4705 and is recommended for use with any quantity of NetBAY enclosures.

Caster Stabiliser

IBM Netfinity Rack Cabinet and Options

Note: For a robust rack configurator application access URL http://www.pc.ibm.com/europe/configurators

Rack Enclosure

P/N 9306900

1

,

P/N 9306910

1

1st Console

Switch, if no monitor compartment

C

2nd PDU

14

13

12

11

10

9

8

7

6

20

19

18

17

16

15

5

4

3

2

1

30

29

28

27

A 26

25

24

23

22

21

34

33

32

31

38

37

36

35

42

41

40

39

B

42U

Vertical Rack Mount Area

22U

D

Special Side Wall

Compartments

1st PDU

1st Console

Switch, if no monitor compartment, or 2nd PDU

A 14

13

12

11

10

9

8

7

6

22

21

20

19

18

17

16

15

5

4

3

2

1

1. P/N 9306900 includes a glass front door and no side panels.

P/N 9306910 includes a perforated front door and side panels.

NetBAY22

P/N 9306200

Mounting Location for Display and

Keyboard

E

D

1st PDU

Direct Rack Mount

1

: Units Supported Examples

IBM Servers

Netfinity 4000R xSeries 330 xSeries 340 / Netfinity 4500R xSeries 230 / Netfinity 5100 xSeries 240 / Netfinity 5600

Netfinity 6000R

Netfinity 7100

Netfinity 7600

Netfinity 8500R

All Models

All Models

All Models

Rack Models

Rack Models

All Models

Rack Models

All Models

All Models

IBM Storage Expansion Units

1U

3

1U

4

3U

5U

5U

5U

8U

8U

8U

2

Netfinity EXP15

Netfinity EXP200

Netfinity EXP300

P/N SE2RXxx

P/N 00N6xxx

P/N 19K11xx

IBM Fibre Solutions

3U

3U

3U

RAID Controller Unit

FAStT500 Storage Server

FAStT500 EXP500 Expansion Unit

SAN FC Managed Hub

8-port Switch

16-port Switch

FAStT200 Storage Server

P/N SFCU1xx

P/N 00N69xx

P/N 00N71xx

P/N 35L1647

P/N 2109S08

P/N 2109S16

P/N 19K11xx

IBM Tape Unit Enclosures

NetMEDIA Enclosure P/N 03K8756

IBM Networking Products

1U

2U

3U

4U

4U

3U

1U

3U

Dial-in Access to LANS 8235-03x 1U

New Rack Options

09N4290

09N4291

09N4293

37L68xx

1

37L68xx

2

37L6885

NetBAY 1x4 Console Switch

NetBAY 2x8 Console Switch

NetBAY 7-foot Console Cable Set

NetBAY Server Dual Cord Power Distribution Unit

NetBAY Rack Power Distribution Unit

NetBAY Single Phase Front-End Power Distribution Unit

37L6883

37L6887

NetBAY Single Phase Front-End Power Distribution Unit with 120V Line Cord

NetBAY Three Phase Front-End Power Distribution Unit

1. Where xx provides a country line cord: 65=US, 67=EUR, 69=Den/Switz, 71=Israel, 73=Italy,

65=Saudi Arabia, 75=S/Africa, and P/N 06P6027=UK.

2. Where xx provides a country line cord: 66=US, 68=EUR, 70=Den/Switz, 72=Israel, 74=Italy,

66=Saudi Arabia, 76=S/Africa, and P/N 06P6028=UK.

1. Mounting hardware provided with product

2. Netfinity 8500R requires installation of extension kit P/N 36L9703 or 36L9702 when installed in a Rack 9306900/910 or NetBAY22

P/N 9306200 respectively for proper rear door closure clearance.

3. To provide adequate cooling, a blank filler panel should be placed on the front of any unused rack space. If non-IBM racks are to be used, assure that both front and rear doors offer approximately 60% open area uniformly distributed and in line with installed servers. A clearance of 51 to 64-mm (2 to 2-1/2 inches) must be maintained between the front door and the system unit’s front bezel. The rear door must maintain the same or greater distance. Clearance between the EIA mounting rails and rack side covers must be less than 13-mm (1/2-inch) to prevent air recirculation from back to front. Non-rack installations are not supported.

4. To provide adequate cooling, Blank Filler Panel Kit (P/N 94G6670) should be placed on the front of any unused rack space. If non-IBM racks are to be used, assure that both front and rear doors offer a minimum of

48% open area uniformly distributed and in line with installed servers. A clearance of 51 to 64-mm (2 to 2-1/2 inches) must be maintained between the front door and the system unit’s front bezel. The rear door must maintain the same or greater clearance. Clearance between the EIA mounting rails and the rack side covers must be less than 13-mm (1/2 inch) to prevent air re-circulation from back to front. Non-rack or

NetBAY3E installations are not supported.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

138

Updated

17/10/00

139

Updated

17/10/00

Keyboard/Pointer/Monitor & Switch ... all in 3U

Console Switch

• Mounts to rear flanges

• Shares 3U space with display, keyboard and tray

Keyboard Tray Components

• P/N 28L4707 Rack Keyboard Tray

• P/N 37L6888 Flat Panel Monitor Rack Mount Kit II

• P/N 28L36xx Space Saver Keyboard

• P/N 11AG1xx T54A Flat Panel Color Monitor

Front

Keyboard Tray

Mounting Flanges

Slide-Out and Flip-Up

Optional Accessories

Part

Number

Mounting Support

94G7442

36L9702

36L9703

06P6010

Fixed Shelf: width x depth= (439 mm x 663mm) 17.3 in. x

26.1 in max. weight= (45 kg)100lbs.

Netfinity NetBAY22 Rack Extension Kit installs on the rear of a 9306200

1

.

Netfinity Rack Extension Kit installs on the rear of a Rack P/N 9306900 or 9306910

1

.

2 to xx U

Netfinity Rack Front Door Kit

Rack Space

-

-

-

Units Supported

IBM Networking Products

8222-008, 016

8225-003

Nways Enet Wkgp Hub

Ethernet Hub

Netfinity NetBAY22 9306200

Netfinity Rack 9306900, 9306910

Netfinity Rack 9306900

2U

2U

Part

Number

Description Console Support Devices Supported

Devices Height Part Number

Monitors

94G7444 Monitor compartment One monitor and one console

E51 Color Monitor

E54 Color Monitor

E74 Color Monitor

G78 Color Monitor

9U

9U

10U

10U

T3347xx

31H2Nxx

T32N3xx

T274Axx

11AG1xx T54A TFT LCD Color Monitor 3U

Keyboards/Mouses

2

28L4707 Netfinity Rack Keyboard Tray

One flat panel display and one space saver keyboard, and one keyboard mouse

Space Saver Keyboard

3, 4

TrackPoint IV 104-Key 3

Tower Model Keyboards

5

1U

1U

1 to 2U

28L36xx

01K1260

-

Monitors

T54A flat panel monitor

6

Flat Panel Monitor Mount Kit II

7

3U

11AG1xx

37L6888

37L6888

94G7445

28L0542

Flat Panel Monitor Rack Mount Kit

Supports installation of a flat panel monitor into tray 28L4707

T54A Flat Panel Monitor

6

Console Server Selector Switch (8-port, Tier up to 64)

Netfinity Console Server Selector Switch (4port)

Mounts behind monitor compartment or in rack side

When used with keyboard tray 28L4707 and flat panel kit 37L6857 it can also be installed behind the keyboard tray.

Console Cable Set - 12ft. (366 m)

Monitors

-

11AG1xx

94G7447

94G7447 NetBay Console Cable Set- (3.66 m) 12 ft.

Attaches server to console switch

Console Server Selector Switch (8-port)

Netfinity Console Server Selector Switch (4-port) -

94G7445

28L0542

1.Expands current racks for better cable management or to accomodate systems requiring greater installation depth.

2. Check system sections for support of desired keyboards, mouse and monitors.

3. Advanced TrackPoint IV features are not supported by Netfinity servers or rack console switches.

4. Space saver keyboards may be stowed in a ready-to-use position within tray 28L4707.

5. Tower models of Netfinity servers includes keyboards, which are supported by both keyboard trays and console switches. These are not space saver keyboards.

6. Installation in a Netfinity Rack Keyboard Tray P/N 28L4707 requires Netfinity Flat Panel Monitor Rack Mount Kit P/N 37L6888. A space saver keyboard may coexist within keyboard tray P/N 28L4707.

7. When installed in Netfinity Rack Keyboard Tray P/N 28L4707 a flat panel monitor and space saver keyboard may coexist in the tray. Hardware is included for mounting a console selector switch to the rack directly to the rear of the tray thus sharing the same 3U space. See the Keyboard/Pointer/Monitor & Switch diagram above.

Part

Number

Power Support Rack Space Comments

2PDUxxx

1

14RIxxx

30RIxxx

94G7448

1

1

200-240V 16a Power Distribution Unit

1400VA UPS 220-240V EMEA/

AP

3000VA UPS 220-240V EMEA/

AP

Power Cable

Type Connectors

C12 IEC 320-C13 to IEC 320-C14

--

3U

3U

-

10 IEC 320-C13 outlets

Mounts in rack side wall D,C

4 IEC 320-C13 outlets

8 IEC 320-C13 and 1 C19

Length

(3.66 m) 12 ft.

Part

Number

Miscellaneous Rack Space Comments

94G6670

Blank Filler Panel Kit

1U panel (qty. = 2)

3U panel (qty. =1)

5U panel (qty. = 1)

1U + 1U

3U

5U

Use as required to fill empty space in the vertical rack mount area.

Note: You can select up to two power units per rack. Select the optional Power Cables when the standard cable is not long enough or has incompatible power plug.

1. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,

UKM=United Kingdom, EUR=Europe.

Single Cabinet or Multi-Rack Suite Options using Rack Cabinet P/N 9306900

Side Panel Kit (94G6669)

1

Single Stand-alone

IBM Netfinity Rack Cabinet

2 Locking Side

Panels

Rack Attachment Kit (94G7446)

2

Bolts, Brackets, and Trim Pieces front and side stabilisers required

Multi-Rack Suites -- 2 to 8 racks

1. Supported on Rack Cabinet P/N 9306900 only. Included with Rack

Cabinet P/N 9306910.

2. Supported on P/Ns 9306900 and 9306910 side stabilisers not required

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

140

Updated

17/10/00

141

Updated

17/10/00

36 in.

914 mm

Dimensions for

NetBAY22

P/N 9306200

90 in.

2286 mm

Side Stabilizers not required on a

NetBAY22

P/N 9306200

Netfinity Rack Cabinet P/Ns 9306900, 9306910 and NetBAY22 P/N 9306200 Dimensions

42 in.

1067 mm

23.6 in.

600 mm

26 in.

660 mm

30 in.

762 mm

36 in.

914 mm Front View

25.5 in.

648 mm

42U

22U

Top View

5.6 ft.

.52m

2

2

(23.5 in. x 34.in.)

(597mm x 864mm)

34.5 in.

876 mm

30 in.

762 mm

60 in.

1524 mm

Side Stabilisers not required on a

NetBAY22

P/N 9306200 Service Clearance

(8 ft. x 10.4 ft. = 83.2 ft.

2 )

(2438 mm x 3170 mm = 7.73 m 2 )

Front

Operational Clearance

(3.5 ft. x 7.5 ft. = 26.25 ft.

2

)

(1067 mm x 2286 mm = 2.44 m

2

)

12 in.

305 mm

Dimensions for

NetBAY22

P/N 9306200

81.5 in.

2070 mm

46.25 in.

1175 mm

EIA 310-D standard 19-inch, type A cabinet

1U = (44.45 mm)1.75 inches

Weight (lb/kg)

Empty rack

Max load

Total

31.8 in. (807.7 mm)

(surface to surface)

Rack Cabinet P/Ns 9306900,

9306910

Moveable Stationary

276/125

824/374

1100/499

276/125

1424/646

1700/771

NetBAY22 P/N 9306200

Moveable or Stationary

182/83

746/338

928/421

Internal Dimensions

Top View

Front to lock = 1.4 in.

(35.6 mm) to door = 2.3 in.

(58.4 mm)

28.125 in.

(714.4 mm)

(inside flange to inside flange) to frame = 2.2 in.

(55.9 mm) to glass = 3.0 in.

(76.2 mm)

Switch Arrangements

Tiering

Console

Mounting flange dimensions and universal hole spacing defined by

EIA 310 for 19-inch racks

Single Switch

Console

Primary Switch

Switch

Secondary Switch Secondary Switch console cable set console cable set

Up to 4 or 8 Servers

(depending on switch type)

Up to 64 Servers

(depending on switch type)

Appendix A: Tape Drive Attributes

Form Factor

LEGEND

HH: Half High - approx. height of 1.6”

SL: Slim Line - approx. height of 1”

FH: Full High

Description

01K1282

09N4041

00N7991

01K1319

09N4042

31/08/00 12/24GB DDS/3 4mm Internal Tape Drive

-

-

31/08/00 10/20GB NS Internal SCSI Tape Drive

-

12/24GB DDS/3 4mm Internal Tape Drive

20/40 GB DDS/4 4-mm Internal Tape Drive

10/20GB NS Internal SCSI Tape Drive

01K1325 20/40GB 8mm Internal SCSI Tape Drive

01K1320 25/08/00 20/40GB DLT SCSI Tape Drive

09N4040 20/40GB DLT Internal SCSI Tape Drive

00N7990

00N8017

00N8016

00N7956

94G7587

36L9636

10K2340

00N79xx

14

00N7992

-

-

-

-

-

-

-

-

-

40/80 GB DLT Internal SCSI Tape Drive

60/120 GB 8mm M2 SCSI Tape Drive

100/200 GB LTO Tape Drive

Associated Options

68-pin External Multimode LVD/SE

SCSI Terminator

PC Server SCSI Terminator Kit

Netfinity Two-Drop Internal SCSI Cable

6

Media Bay Tray and LVD Cable Kit

7

Tape Autoloaders

DLT Tape Autoloader

120/240 GB DDS/4 Tape Autoloader

8

8

16 Ultra2

LVD

8

8

16

8

8

16 Ultra2

LVD

16 Ultra2

LVD

16 Ultra2

LVD

89 mm (3.5”)

HH or 133 mm

(5.25”)HH

89 mm (3.5”)

HH or 133 mm

(5.25”)HH

89 mm (3.5”)

HH or 133 mm

(5.25”)HH

89 mm (3.5”) SL or 133 mm

(5.25”)HH

89 mm (3.5”) SL or 133 mm

(5.25”)HH

133 mm

(5.25”)HH

133 mm

(5.25”)FH

133 mm

(5.25”)FH

133 mm

(5.25”)FH

133 mm

(5.25”)HH

133 mm

(5.25”)FH

12/24

12/24

20/40

10/20

10/20

20/40

20/40

20/40

40/80

60/120

100/200

1.1/2.2

1.1/2.2

2.75/5.5

1/2

1/2

3/6

1.5/3

1.5/3

6/10

12/24

15/30

Y

3

Y

Y

Y

Y

N

Y

N

N

N

N

Y

Y

N/A

Y

Y

N/A

Y

Y

N/A

N/A

N/A

-

-

-

-

-

-

-

-

-

-

-

16 LVD/SE

8/16

16

16 LVD

16

16 Ultra2

LVD

Ext.

Int.

Int.

Int.

Desktop

133 mm

(5.25”)FH

-

-

-

-

280/560

120/240

-

-

-

-

5/10

3/6

1/1

1/1

1/1

1/0

1/0

1/1

1/1

1/1

1/1

1

12

1/1

10L7440

03K8756

10L7440

03K8756

10L7440,

03K8756

3

10L7440,

03K8756

10L7440,

03K8756

10L7440

4,

03K8756

03K8705,

03K8756

03K8705

4

,

03K8756

03K8705

03K8756

4

3

,

10L7440

03K8756

4

3

,

03K8756

3

Y

N

Y

Y

Y

Y

N

N

N

N

-

-

16-bit,

2-drop

16-bit

2-drop

-

-

-

-

-

N

-

-

1/1

5/1

10L7440,

03K8705

-

-

03K8756

-

03K8756

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

142

Updated

17/10/00

Form Factor

LEGEND

HH: Half High - approx. height of 1.6”

SL: Slim Line - approx. height of 1”

FH: Full High

Description

External Tape Enclosures

10L7440 External Half High SCSI Storage Enclosure

8

8/16 Desktop N N

8-bit or

16-bit

-

03K8756 NetMEDIA Storage Expansion Unit EL

9

16 Rack Y N

16-bit,

4-drop

-

10L7113

03K8705

-

-

NetMEDIA Systems Management Adapter

10

DLT External SCSI Enclosure

11

16

16

-

Desktop

-

-

-

-

N

N

N

N

N

16-bit

-

-

03K8756

-

1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section and the desired enclosure then refer to Appendix D: Cables-

Storage Units-Controllers.

2. Data compression typically provides a 2X improvenent in capacity and transfer rate, bur since data compression is affected by many factors, actual improvements may be more or less than 2X.

3. LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL P/N 03K8756 requires replacement of the standard single-ended internal cables with one or more (depending on configuration) cables from Media Bay Tray and LVD Cable Kit P/N 10K2340 which contains a single two-drop multi-mode terminated cable. If the standard cables are used for attachment to LVD devices, single-ended SCSI rules and bus speeds apply.

4. Requires 68-pin External Multimode LVD/SE SCSI Terminator P/N 00N7956.

5. Requires installation of the multi-mode terminated LVD cable from Media Bay Tray and LVD Cable Kit P/N 10K2340.

6. Netfinity Two-Drop Internal SCSI Cable P/N 36L9636 is a single-ended wide two-drop terminated cable.

7. Media Bay Tray and LVD Cable Kit P/N 10K2340 includes an internal two-drop multi-mode terminated LVD SCSI cable.

8. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2 16-bit Active

Termination P/N 32G3918.

9. NetMEDIA Storage Expansion Unit EL P/N 03K8756 is a black 3U, 19” rack or NetBAY3/3E mountable tape enclosure which includes two full high (FH) or four half-high (HH) extended length 5.25” bays, two external 68-pin high density connectors and two internal four-drop single-ended terminated 16-bit SCSI cables for device attachment. Two power supplies and two standard country power cords are also included.

10. NetMEDIA Systems Management Adapter P/N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and auto-termination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

11. Provides a black desktop DLT tape enclosure, with a 68-pin high density external connector. Requires termination by the tape drive or by installation of 68-pin External Multimode LVD/SE SCSI

Terminator P/N 00N7956.

12. A combination data/cleaning cartridge cleans the drive each time the data cartridge is used.

13. Not available from IBM after this date. Business Partner inventory may be available.

14. Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

Note: Tape support varies by system depending on internal bay availability, SCSI cabling type, number of cable drops, existence of a RAID controller and availability of a suitable external enclosure. The following general rules should be followed.

a) Tapes are not supported for attachment to RAID controllers.

b) Single-ended (non-LVD) devices may be attached to internal multi-mode terminated cables. The entire SCSI bus will be limited to single-ended operation with a maximum bus speed of Ultra-SCSI.

c) LVD devices attached to single-ended terminated cables will operate in single-ended mode with a maximum bus speed of Ultra-SCSI.

Internal SCSI Cables and Optional SCSI Adapters

Most systems support the following SCSI adapters for use with tape. Consult the I/O Options table in the system sections for specific system support. Where tapes are supported internal to the system, the cables which ship with the adapters are supported for tape attachment. Some restrictions may apply based on cable and tape type which are explaned in the note above.

Part Number

02K3454

19K4646

36L9636

10K2340

Description Cable Description

PCI Fast/Wide Ultra SCSI Adapter

PCI Wide Ultra160 SCSI Adapter

Four-drop, single-ended terminated, 16-bit

Five-drop, multi-mode terminated

Netfinity Two-Drop Internal SCSI Cable Two-drop, single-ended terminated, 16-bit

Media Bay Tray and LVD Cable Kit Two-drop, multi-mode terminated

143

Updated

17/10/00

Appendix B: Tape Library Attributes

SCSI INTERFACE

LEGEND

F: Female - External

M: Male - External

68: 16-bit, 68-pin High Density connector

0.8: 16-bit, 68-pin Very High Density Connection

Interface (VHDCI) 0.8 mm connector

Diff: Differential SCSI

Description

00N79xx

4

DLT Tape Autoloader M68 Desktop Y

M0.8mm - F68

Converter

Y 1/7 1 1/1 1/1 280/560 5/10

00N79xx

5

00N79xx

5

33L4979

DLT Tape Library - Tower

DLT Tape Library - Rack

2

DLT Library Drive Upgrade

3

M68

M68

Desktop

4U Rack

Y

Y

M68-M68 (3)

M68-M68 (3)

Y

Y

1/14

1/14

1

1

2/2

2/2

1/3

1/3

490/980

490/980

5/10

5/10

M68 N Jumper N 5/10

1. Transfer rates are for single SCSI Channel configurations. Tape Libraries utilizing split library or dual host configurations may obtain higher rates. Data compression typically provides a 2X improvement in capacity and transfer rate, bur since data compression is affected by many factors , actual improvements may be more or less than 2X.

2. Includes Fixed Shelf P/N 94G7442 for installation in an IBM Rack or NetBAY22.

3. Upgrade 33L4979 is an additional drive for DLT Tape Libraries. Up to two tape drives may be installed for a maximum of three drives per DLT Tape Library

4. Where ‘xx’ represents a country specific power cord code: 70=UK, 71=Swiss, 72=Italy, 73=Israel, 33L4981=EU1, 33L4982=Denmark, 33L4983=South Africa/India.

5. Where ‘xx’ represents a country specific power cord code: Tower versions - 74=EU1, 75=Denmark, 76=India/South Africa, 77=UK, 78=Swiss, 79=Italy, 80=Israel: Rack versions - 81=EU1,

82=Denmark, 83=India/South Africa, 84=UK, 85=Swiss, 86=Italy, 87=Israel.

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

144

Updated

17/10/00

145

Updated

17/10/00

Appendix C: UPS Runtime Estimate (minutes)

Servers

Netfinity 1000

2

Netfinity 3000

2

Netfinity 3500 M20

2

Netfinity 4000R xSeries 200

2 xSeries 220

2 xSeries 230 / Netfinity 5100

2 xSeries 240 / Netfinity 5600

2 xSeries 330

2 xSeries 340 / Netfinity 4500R

2

Netfinity 6000R

2

Netfinity 7100

2

Netfinity 7600

2

Netfinity 8500R

2

Other Devices

Fibre Channel RAID Controller Unit (P/N SFCU1xx)

2

FAStT500 Storage Server (P/N 00N69xx)

2

FAStT EXP500 Storage Expansion Unit (P/N 00N71xx)

2

FAStT200 Storage Server (P/N 19K11xx)

2

FAStT200 HA Storage Server (P/N 19K11xx)

2

EXP200 Storage Expansion Unit

2

EXP300 Storage Expansion Unit

2

SAN Fibre Channel Switch 8-port (P/N 2109S08)

SAN Fibre Channel Switch 16-port (P/N 2109S16)

# Pwr. Cords Std/Max

2/2

2/2

2/2

2/2

2/2

1/1

1/3

2/3

1/1

1/2

1/4

2/4

3/4

3/3

1/1

1/1

1/1

1/1

1/1

1/2

2/2

1/2

1/2

Watts Load Max./Typ.

225/160

225/160

430/300

150/105

350/245

350/245

375/250

450/315

220/160

390/270

525/395

475/330

475/330

1450/1015

160/105

200/140

350/245

390/275

390/275

350/280

360/285

200/140

200/140

1

SAN Data Gateway Router (P/N 2108R3S)

DLT Tape Autoloader and Library (P/N 00N79xx)

1/1

1/1

90/60

135/100

NetMEDIA Storage Expansion Unit EL (P/N 03K8756) 2/2 185/130

1. This table represents general guidelines for selecting the appropriate UPS based on minimum and typical runtime estimates. A ‘maximum configuration’ load will result in ‘minimum’

UPS runtime. ‘Typical’ loads are based on a production system running at approximately 70% of maximum capacity. The ‘typical’ loads represent a more likely configuration and, therefore, a more likely estimate of runtime. Customer environments are unique and are unlikely to be precisely represented by any of the specific entries in the table.

2. Power-Factor Corrected (PFC) power supply.

UPS Attributes

1

Communications Links to Servers

Color

EIA Height

EMEA Models

50 or 60 Hz, single phase, VAC:

EMEA

P/N

SU-700iNET

P/N

SUP072Y

US

P/N

SU-

700NET

94G3134

1 black

-

220-240 (208)

2

Tower

SU-1000iNET

P/N

SUP102Y

SU-

1000NET

94G3135

SU-1400iNET

P/N

SUP142Y

SU-

1400NET

94G3136

SU-2200iNET

P/N

06P60xx

6

Not Available

1 black

-

220-240 (208)

2

1 black

-

220-240 (208)

2

1 beige

-

220-240 (208)

2

SU-

1400RMiB

P/N 14RIxxx

7

Rack Mounted

SU-

3000RMiB

P/N 30RIxxx

7

SU-

1400RMB

94G6674

SU-

3000RMB

94G6676

SU-

5000RMiB

P/N 37L6862

SU-

5000RMB

37L6861

1 black

3U

220-240 (208)

2

3 black

3U

3 black

5U

220-240 (208)

2

220-240 (xxx)

2,

3

10 Amp, IEC 320-C13

(Device) receptacles

16 Amp, IEC 320-C19

(PDU P/N 2PDUxxx) receptacles

Line Cord Receptacle (IEC 320- )

US Models

50 or 60 Hz, single phase, VAC:

Receptacles (NEMA 5-15R)

10 Amp, IEC 320-C13

(Device) receptacles

16 Amp, IEC 320-C19

(PDU 94G7450) receptacles

Line Cord Length, NEMA Plug

4

-

C14

120 (120)

2

4

-

-

6 ft., 5-15P

4

-

C14

120 (120)

2

6

-

-

6 ft., 5-15P

4

-

C20

120 (120)

2

6

-

-

6 ft., 5-15P

8

1

C20

-

-

-

-

-

4

-

C14

120 (120)

2

6

-

-

6 ft., L5-15P

8

1

C20

120 (120)

2

8

-

-

6 ft., L5-30P

8

2

TB

5

200-220 (208)

2

-

8

2

4

8 ft., L5-30P

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

146

Updated

17/10/00

147

Updated

17/10/00

1. Data provided by APC.

2. How-to-Read example for 220-240(208): Input VAC is 220- 240 as is the UPS output when electric service is active. When electriic service is interupted and the UPS is on battery the UPS output is 208 VAC.

3. Battery output may be set to 220, 225, 230, or 240 VAC.

4. Two PDU jumper cables ship with the UPS for attachment from the IEC 320-C19 receptacles to Power Distribution Units (PDU) (P/N 2PDUxxx).

5. SU-5000RMiB (P/N 37L6862) contains a Terminal Block (TB) for direct attachment to an electrical source by qualified personnel.

6.Where ‘xx’ represents the appropriate country code as follows:- 14=UK, 15=Denmark/Switzerland, 16=EUR, 17=Israel, 18=Italy, 19=South Africa.

7. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom, EUR=Europe.

Total Configuration Runtime Estimator (Time in minutes)

1

Tower Rack Mount

EMEA

Part Number

US

Part Number

SU-700iNET

P/N SUP072Y

SU-700NET

94G3134

SU-1000iNET

P/N SUP102Y

SU-1000NET

94G3135

SU-1400iNET

P/N SUP144Y

SU-1400NET

94G3136

SU-2200iNET

P/N 06P60xx

5

Not Available

SU-1400RMiB

P/N 14RIxxx

94G6674

6

SU-1400RMB

SU-3000RMiB

P/N 30RIxxx

6

SU-3000RMB

94G6676

SU-5000RMiB

P/N 37L6862

SU-5000RMB

37L6861

Total Load (Watts) Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes

-

-

-

-

-

-

9

7

5

22

17

12

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1900

2000

2100

2200

2300

2400

1300

1400

1500

1600

1700

1800

2500

2600

2700

2800

1. Data provided by APC.

500

550

600

650

700

750

200

250

300

350

400

450

800

850

900

950

1000

1100

1200

7

6

-

11

9

8

18

14

12

38

28

22

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

12

11

10

18

16

13

29

23

20

62

43

34

-

-

6

-

9

8

7

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

31

28

25

43

38

34

130

104

85

71

65

52

18

17

15

13

23

21

19

-

-

-

-

-

-

-

-

-

-

8

-

-

11

9

9

9

8

8

13

11

10

22

18

15

45

34

25

-

-

5

-

7

7

6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

29

26

24

38

35

31

58

52

45

104

84

70

17

16

14

12

22

20

18

8

7

-

10

9

8

-

-

-

-

-

-

-

68

63

59

97

87

76

240

200

166

145

125

110

43

39

34

31

55

51

47

11

10

10

14

12

11

8

8

9

9

20

18

17

28

25

22

Steps:

1. Identify the devices contained in the configuration.

2. Sum the load (watts) of all devices in the configuration. Use either Maximum Load for minimum runtime, or Typical Load for typical runtime.

3. Find the Total Configuration Load in the table above.

4. Select the most appropriate UPS model to achieve the desired runtime.

5. Where ‘xx’ represents the appropriate country code as follows:- 14=UK, 15=Denmark/Switzerland, 16=EUR, 17=Israel, 18=Italy, 19=South Africa.

6. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom, EUR=Europe.

NOTE: If the Total Configuration Load is greater than the entries above, split the load across two or more UPS units.

Appendix D: Cables - Storage Units - Controllers

F: Female - External

M: Male - External

I: Internal

68: 16-bit, 68-pin High Density connector

50: 8-bit, 50-pin Centronix Connector

0.8: 16-bit, 68-pin Very HighDensity Connection

Interface (VHDCI) 0.8 mm connector

16: 16-bit, 68-pin connector

8: 8-bit, 50-pin connector

Description

RAID Storage Controllers

Netfinity Fibre Channel RAID Controller Unit

Netfinity ServeRAID-4L Ultra160 SCSI Controller

Netfinity ServeRAID-4M Ultra160 SCSI Controller

Netfinity ServeRAID-4H Ultra160 SCSI Controller

Netfinity ServeRAID-3HB Ultra2 SCSI Adapter

Netfinity ServeRAID-3L Ultra2 SCSI Adapter

Netfinity ServeRAID-3L Ultra2 SCSI Adapter II

Ultra160 SCSI Controllers

PCI Wide Ultra160 SCSI Adapter

Netfinity 6000R - Ultra160 SCSI

Ultra2 SCSI Controllers

Netfinity 3000 - Model P/Ns 780UExx and up xSeries 240 / Netfinity 5600

Netfinity 7100

Netfinity 7600

Netfinity 8500R

Ultra SCSI Controllers

PCI Fast/Wide Ultra SCSI Adapter

Netfinity 3000 - Model P/Ns 771UExx and before

Netfinity 4000R - non-RAID models

No Onboard External Port

22

Netfinity 1000 Value Model (IDE)

Netfinity 3500 M20

Netfinity 4000R - RAID models xSeries 200 xSeries 220 xSeries 330 xSeries 340 / Netfinity 4500R xSeries 230 / Netfinity 5100

Related Options

0.8mm to 68-pin SCSI Adapter

Cable Group A (M0.8-M0.8)

Netfinity 2M Ultra2 SCSI Cable

Netfinity 4.2M Ultra2 SCSI Cable

Netfinity 20 M Ultra2 SCSI Cable

Cable Group B (M68-M0.8)

IBM 2M External .8mm SCSI Cable

Cable Group C (M68-M68)

PC Server F/W to F/W External SCSI Cable-1m

SFCU1xx

37L6091

37L6080

37L6889

37L6086

01K7364

19K0564

19K4646

Onboard

Adapter

Onboard

Onboard

Onboard

Onboard

02K3454

Adapter

Adapter

N/A

Onboard

Adapter

Onboard

Onboard

Onboard

Onboard

Onboard

Part

Number

Instructions: Identify Desired Controller Row and Storage Unit Column. The intersection of row and column contains the cable group letter which supports the connection. Go to the cable group under the corresponding storage unit for specific support. Read all Notes for row, column, and any cable group footnotes.

Storage Enclosure Unit

EXP15

SE2RXxx

EXP200

00N6xxx

19

EXP300

19K11xx

External HH

SCSI

10L7440

DLT Ext.

SCSI

03K8705

NetMEDIA

03K8756

NetMEDIA

Adapter

10L7113

Max.MB/sec.)

1

LVDS

Connector Type

40

X

F0.8

80

X

F0.8

160

X

F0.8

-

-

F68 or F50

-

-

F68

-

X

F0.8

-

-

F0.8

Max./

Channel

(MB/sec)

1

LVDS

Connector

Type/ Max

Note # 2, 3 2, 4 2, 5 6 6, 7 2, 6 2, 6, 8

160

160

80

80

80

80

80

40

40

40

80

160

160

160

80

80

80

-

-

80

-

-

-

-

-

X

X

X

X

X

X

X

-

-

-

X

X

X

X

X

X

X

X

-

-

-

-

-

-

-

F0.8/1

F0.8/1

F68/1

F0.8/1

F0.8/1

F0.8/1

F0.8/1

F68/1

F68/1

F68/1

F0.8/6

F0.8/1

F0.8/2

F0.8/4

F0.8/3

F0.8/1

F0.8/1

N/A

N/A

F0.8/1

N/A

N/A

N/A

N/A

N/A

-

-

-

-

-

B

11

-

-

-

-

-

-

-

-

-

-

A

A

A

A

A

A

A

-

-

-

-

-

-

-

B

11

-

-

-

-

-

-

-

-

-

-

A

A

A

A

A

A

A

-

-

-

14

-

-

-

-

-

-

-

-

9

13

13

13

-

-

-

15

-

21

-

-

-

-

-

B

B

C

B

B

B

-

C

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

B

B

C

B

B

-

-

C

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

A

A

-

A

A

A

A

-

-

-

-

-

-

-

-

A

A

-

A

A

A

A

B

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

B

B

-

B

B

C

23

-

B

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

B

B

01K8017 M0.8-F68 16 -

03K9310

03K9311

37L7101

01K8027

SS2C02Y

-

-

-

-

-

X

X

X

-

-

M0.8-M0.8

M0.8-M0.8

M0.8-M0.8

M68-M0.8

M68-M68

15

15

10

-

23

X

X

X

10

X

-

-

X

18

X

X

10

X

-

-

X

18

X

X

X

-

-

-

-

X

X

-

-

-

X

X

X

X

23

X

X

-

X

X

-

X

-

F: Female - External

M: Male - External

I: Internal

68: 16-bit, 68-pin High Density connector

50: 8-bit, 50-pin Centronix Connector

0.8: 16-bit, 68-pin Very HighDensity Connection

Interface (VHDCI) 0.8 mm connector

16: 16-bit, 68-pin connector

8: 8-bit, 50-pin connector

Part

Number

Instructions: Identify Desired Controller Row and Storage Unit Column. The intersection of row and column contains the cable group letter which supports the connection. Go to the cable group under the corresponding storage unit for specific support. Read all Notes for row, column, and any cable group footnotes.

Storage Enclosure Unit

EXP15

SE2RXxx

EXP200

00N6xxx

19

EXP300

19K11xx

External HH

SCSI

10L7440

DLT Ext.

SCSI

03K8705

NetMEDIA

03K8756

NetMEDIA

Adapter

10L7113

Max.MB/sec.)

1

40 80 160 -

LVDS X X X X -

Connector Type F0.8

F0.8

F0.8

F68 or F50 F68 F0.8

F0.8

Max./

Channel

(MB/sec)

1

LVDS

Connector

Type/ Max

Note # 2, 3 2, 4 2, 5 6 6, 7 2, 6 2, 6, 8 Description

Cable Group D (Short Wave Fibre)

19

Netfinity Fibre Channel 1 M Cable

Netfinity Fibre Channel 5 M Cable

Netfinity Fibre Channel 25 M Cable

Customer supplied cables <500M (0.31 miles)

Cable Group E (Long Wave Fibre)

19

Customer supplied cables < 10 KM (6.2 miles)

Cable Group G (Other)

68-pin External Multimode LVD/SE SCSI Terminator

GBIC

19

Netfinity Fibre Channel Short-Wave GBIC

Netfinity Fibre Channel Long-Wave GBIC

36L9973

03K9306

03K9305

**********

**********

00N7956

-

-

-

-

-

-

N/A

N/A

N/A

N/A

N/A

-

S/W Fibre

S/W Fibre

S/W Fibre

S/W Fibre

L/W Fibre

M68

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

X

-

-

-

-

-

X

-

-

-

-

-

-

-

-

-

-

-

-

03K9308

03K9307

-

-

N/A

N/A

S/W Fibre

L/W Fibre

20

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1. Maximum supported speeds may be limited by installation of lower speed devices, controllers or cable lengths greater than 2 meters.

2. Rack installation cable management requires devices to have a minimum cable length of 2 meters. Cable length requirements will vary based on placement within a single or multiple rack suite.

3. Attachment to wide ultra SCSI controllers limits operational speeds to Ultra SCSI (40 MB/s) for cables up to 2 meters in length and Fast/Wide SCSI (20 MB/s) for cable lengths between 2 meters and 4.3 meters. Ultra2 SCSI controllers and cables allow cable lengths of up to twenty meters at up to 40 MB/s.

4. Attachment to wide ultra SCSI controllers limits operational speeds to Ultra SCSI (40 MBps) for cables up to two meters in length and Fast Wide (20 MBps) for cable lengths between 2 meters and 4.3 meters. Ultra2 SCSI controllers and cables allow cable lengths up to 20 meters at up to 80 MBps.

5. Maximum speeds may be limited by the installed devices or SCSI controller.

6. Daisy chaining tape enclosures is not supported at this time.

7. Requires 68-pin External Multimode LVD/SE SCSI Terminator (P/N 00N7956).

8. NetMEDIA Systems Management Adapter (P/N 10L7113) may be installed in a NetMEDIA Storage Expansion Unit to provide repeater function, LVDS interface, aggregate cable lengths up to 12 meters when attached to an LVD SCSI controller, and autotermination when the Expansion Unit is powered off. External connector is 0.8-mm VHDCI.

9. Connection to either IBM SAN Fibre Channel Managed Hub (P/N 35L1647) or Netfinity Fibre Channel PCI Adapter (P/N 01K7297) requires short wave fibre cables from Cable Group D.

10. Cable lengths exceeding 4.3 meters are NOT supported for attachment to non-Ultra-2 controllers.

11. Installations with cable lengths greater than 2 meters are limited to SCSI Fast/Wide speeds of 20MB/S .

12. RAID support for tape drives is limited to Non-RAID functions and utilisation of a dedicated channel.

13. Maximum speeds may be limited by the enclosure or installed devices.

14. Netfinity 7600 also includes a Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086). See ServeRAID-3HB for connectivity requirements.

15. Does not support external attachment of SCSI devices attached to optional controllers.

16. Converts a F0.8mm into a F68-pin connector for attachment of an external M68 cable .

17. Supports attachment to Ultra-2 or single-ended SCSI controllers with operational speeds of up to Ultra-2. Controller, storage unit, cable length or storage device limitations may apply (see Max. MB/sec row and column above).

18. Netfinity EXP200 (P/N 00N6xxx) and EXP300 (P/N 19K11xx) include a single 2 metre Ultra2 SCSI cable similar to Netfinity 2 M Ultra2 SCSI Cable (P/N 03K9310).

19. See Fibre Array Solutions section for device attachment.

20. Short wave GBICs are included with various devices. See Fibre Array Solutions section for specific details.

21. The RAID adapter has both an internal and external port. Only one of the two ports may be used. The internal HDDs are attached to the RAID adapter therefore the external port must not be used.

22. No external SCSI port is available on these systems. A supported optional controller must be installed. See the systems section to determine which controllers and external storage units are supported then refer back to this table for cable requirements using the controller row. The Netfinity 4000R does not support customer installation of adapters that must be installed inside the server. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.

23. Not supported for use in a rack. Rack installations require a minimum cable length of two meters.

CABLES - STORAGE UNITS -

CONTROLLERS

Appendix E: IBM Serial I/O

IBM Serial I/O Adapters

IBM Serial I/O SST8P

DB Adapter

(P/N 37L1414)

IBM Serial I/O Port Module

Serial I/O

PM16DB Port

Module

(P/N 37L1418)

Serial I/O

PM16RJ Port

Module

(P/N 37L1417)

IBM Serial I/O SST16P

RJ Adapter

(P/N 37L1415)

IBM Serial I/O SST128P

Expandable Adapter

(P/N 37L1416)

Includes two

4’ (1.2 m)

Cables

IBM Serial I/O Power Supply

Serial I/O PS4

Power Supply

(P/N 37L1421)

IBM Serial I/O Multiplexer Sets

Serial I/O 16RJ Multiplexer Set

(P/N 37L1419)

•Multiplexer Interface Unit

•RJ Expansion Module

•Power Supply

•Test Cable

Customer Supplied

Unshielded

Two-Twisted Pair

Cable < 3500’ (1km)

Serial I/O 16DB Multiplexer Set

(P/N 37L1420)

•Multiplexer Interface Unit

•DB Expansion Module

•Power Supply

•Test Cable

Customer Supplied

Unshielded

Two-Twisted Pair

Cable < 3500’ (1km)

SST128P

(P/N 37L1416)

Sample Configurations

PS4

(P/N 37L1421)

37L1414

37L1415

37L1416

37L1417

37L1418

37L1419

37L1420

37L1421

Serial I/O SST8P DB Adapter

1, 5

Serial I/O SST16P RJ Adapter

2, 5

Serial I/O SST128P Expandable Adapter

3, 5

Serial I/O PM16RJ Port Module

4

Serial I/O PM16DB Port Module

4

Serial I/O 16RJ Multiplexer Set

4, 6

Serial I/O 16DB Multiplexer Set

4, 6

Serial I/O PS4 Power Supply

4

4’ (1.2 m)

Cables

Four PM16DB

(P/N 37L1418)

PS4

(P/N 37L1421)

PM16RJ

(P/N 37L1417)

PM16DB

(P/N 37L1418)

Customer

Supplied

Unshielded

Two-Twisted Pair

Cable < 3500’ (1km)

16DB

Multiplexer Set

(P/N 37L1420)

16RJ

Multiplexer Set

(P/N 37L1419)

1. Intelligent serial I/O interface card providing eight DB-25 RS232 serial connections using an octopus cable. Support for all ports at 921.6 Kbps simultaneously.

2. Intelligent serial I/O interface card providing sixteen RJ-45 RS232 serial connections in a breakout box. Support for all ports at 115.2 Kbps simultaneously.

3. Intelligent interface card providing up to 128 RS232 serial connections

(DB25 or RJ45) configured in 16 port increments utilizing any combination of

Port Modules and Multiplexer Sets. Includes two 4' (1.2 m) bus cables. Each 4' cable supports attachment of 1 to 4 Port Modules and/or Multiplexer Interface

Units for a total of 8 per adapter. The first Port Module or Multiplexer Set attached to a cable requires a Serial I/O PS4 Power Supply (P/N 37L1421).

Support for all ports at 115.2 Kbps simultaneously.

4. Port Modules and Multiplexer Sets attach directly to one the two standard 4'

(1.2m) bus cables of the Serial I/O SST128P Expandable Adapter (P/N

37L1416) or directly to 1 or more Port Modules or Multiplexer Sets already attached to one of the cables. A maximum of 4 Port Modules or Multiplexer

Sets may be attached to single cable. The first Port Module or Multiplexer Set attached to a cable requires a Serial I/O PS4 Power Supply (P/N 37L1421).

5. Serial I/O Adapters are 32-bit PCI half length cards. A maximum of four

Serial I/O adapters (in any combination) may be installed in a single host system.

6. Requires a customer supplied Unshielded Two-Twisted Pair (Catagory 3 minimum) cable with a maximum length of 3,500 feet (1 Km).

To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com

150

Updated

17/10/00

Appendix F: IBM ServicePacs for Hardware

Maintenance

IBM Netfinity 24 hour by 7 days cover - 4 hour response target

Model Type Part No xSeries 130 / 135 xSeries 150 xSeries 200 xSeries 220 xSeries 330

Netfinity 1000

Netfinity 3000

Netfinity 3500 M10

Netfinity 3500 M20 xSeries 340 / Netfinity 4500R

Netfinity 5000 xSeries 230 / Netfinity 5100

Netfinity 5500

Netfinity 5500 M10

Netfinity 5500 M20 xSeries 240 / Netfinity 5600

Netfinity 6000R

Netfinity 7000 M10

Netfinity 7100

Netfinity 7600

Netfinity 8500R

14J1468

14J1470

14J1466

14J1466

14J1468

14J1225

72H9988

72H9988

14J1466

14J1468

72H9989

14J1470

72H9989

72H9989

72H9989

14J1316

14J1472

72H9991

14J1330

14J1318

14J1315

IBM Netfinity 9 hour by 5 days cover - 4 hour response target

Model Type Part No xSeries 130 / 135 14J1467 xSeries 150 xSeries 200 xSeries 220 xSeries 330

Netfinity 1000

Netfinity 3000

Netfinity 3500 M10

Netfinity 3500 M20 xSeries 340 / Netfinity 4500R

Netfinity 5000 xSeries 230 / Netfinity 5100

Netfinity 5500

Netfinity 5500 M10

Netfinity 5500 M20 xSeries 240 / Netfinity 5600

Netfinity 6000R

Netfinity 7000 M10

Netfinity 7100

Netfinity 7600

Netfinity 8500R

14J1469

14J1465

14J1465

14J1467

14J1224

14J0528

14J0528

14J1465

14J1467

14J0528

14J1469

14J0528

14J0528

14J0528

14J1317

14J1471

14J0528

14J1320

14J1319

14J1329

151

Updated

17/10/00

Important Notes

IBM reserves the right to change product specifications and to discontinue marketing products without notice.

MHz only measures microprocessor internal clock speed, not application performance. Many factors affect application performance.

When referring to hard drive capacity, MB stands for million bytes and GB stands for one thousand million bytes.Total user-accessible capacity may vary depending on operating environments.

Tape Drives which utilise data compression technology have storage capacity that will vary depending upon whether the drive is operating in native mode

(without compression) or compressed mode. Actual storage capacity will vary based upon many factors and may be less than the maximum possible.

Maximum internal hard disk drive capacities assume the replacement of any hard disk drives and the population of all hard disk drive bays with the largest currently supported drives available from IBM.

The information contained in this document has not been submitted to any formal IBM test and is distributed AS IS. The use of this information or the implementation of any of these techniques is a customer responsibility and depends on the customer’s ability to evaluate and integrate them into the customer’s operational environment. While each item may have been reviewed by IBM for accuracy in a specific situation, there is no guarantee that the same or similar results will be obtained elsewhere. Customers attempting to adapt these techniques to their own environments do so at their own risk.

For more information on IBM’s statement of Limited Warranty, please contact your IBM representative or reseller. Copies are available upon request.

Unless otherwise stated, IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM.

Applications included in IBM products may vary from retail versions and may not include all documentation or functions. Not all products are sold separately.

This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information is subject to change without notice. Consult your local IBM representative for more information on the products, services and features available in your area.

©IBM Personal Systems Group

Department 2W6A

3039 Cornwallis Rd.

Research Triangle Park, NC 27709

Printed in the United States of America

All the part numbers referenced in this publication are product part numbers and not service part numbers.

This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of this publication. IBM may make improvements and/or changes in the product(s) and/or program(s) described in this publication at any time. IBM reserves the right to alter specifications and other product information without notice. It is your responsibility to obtain the latest information.

Other part numbers in addition to those listed in this document may be required to support a specific device or function.

Data on competitive products is obtained from publicly obtained information and is subject to change without notice. Please contact the manufacturer for the most recent information.

This IBM equipment is subject to applicable rules and regulations of the United States Federal Communication Commission (FCC).

The following items are trademarks or registered trademarks of IBM Corporation in the United States or other countries or both: AT, Flo Thru, HelpWare,

IBM, IntelliStation, LANStreamer, MWave, Netfinity, OS/2, Predictive Failure Analysis, SurePath, TechConnect,

WIN-OS/2, 800-CALL-IBM, ServerProven™.

TME 10 Netfinity is a trademark of Tivoli Systems, an IBM Company. Lotus, Lotus Notes and Lotus SmartSuite are trademarks of Lotus Development

Corporation.

Intel, Pentium Pro and Pentium II and MMX are trademarks or registered trademarks of Intel Corporation. Microsoft, Windows and Windows NT are trademarks or registered trademarks of the Microsoft Corporation. UNIX is a registered trademark in the United States and other countries or registered trademarks licensed exclusively through X/Open Company Limited. Trinitron is a trademark of the Sony Corporation. Java and HotJava are trademarks of

Sun MicroSystems, Inc. Adobe and PostScript are trademarks of Adobe Systems, Inc., APC is a trademark of American Power Conversion, Inc. All other registered trademarks and trademarks are properties of their respective owners.

152

Updated

17/10/00

To access information on the World Wide Web, use address: http://www.pc.ibm.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project