Dell OpenManage Server Administrator Version 8.3 software Owner's Manual
Add to my manuals
215 Pages
advertisement
Dell OpenManage Server Administrator
Version 8.3 Command Line Interface Guide
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2016 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2016 - 3
Rev. A00
Contents
1 Introduction.........................................................................................................10
2 Using The omhelp Command...........................................................................15
3 omreport: Viewing System Status Using The Instrumentation Service....17
Omreport chassis hwperformance or omreport mainsystem hwperformance .........................28
3
Omreport chassis pwrmanagement or omreport mainsystem pwrmanagement .....................36
Omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring .............................37
Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess ............................39
Omreport Chassis Removableflashmedia Or Omreport Mainsystem
Omreport System Events Type Or Omreport Servermodule Events Type .................................46
Omreport System snmptrapdest Or Omreport Servermodule snmptrapdest ............................47
Omreport System Operatingsystem Or Omreport Servermodule Operatingsystem ................ 48
Omreport System Pedestinations Or Omreport Servermodule Pedestinations ........................ 48
Omreport System Platformevents Or Omreport Servermodule Platformevents .......................49
Omreport System Shutdown Or Omreport Servermodule Shutdown .......................................50
Omreport System Thrmshutdown Or Omreport Servermodule Thrmshutdown ...................... 55
4 Omconfig: Managing Components Using The Instrumentation
Service......................................................................................................................58
4
Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode ............................ 86
Omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement .................... 87
Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring ......................... 89
Omconfig chassis remoteaccess or omconfig mainsystem remoteaccess ............................... 91
Omconfig system pedestinations or omconfig servermodule pedestinations ........................ 123
Omconfig system platformevents or omconfig servermodule platformevents .......................123
Omconfig system snmptraptest or omconfig servermodule snmptraptest .............................126
Omconfig System Webserver Or Omconfig Servermodule Webserver ................................... 128
Omconfig System Shutdown Or Omconfig Servermodule Shutdown .................................... 129
Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown ................... 130
5 Omconfig System Or Servermodule Assetinfo: Editing Cost Of
Ownership Values................................................................................................ 132
5
6 Using The Storage Management Service.....................................................144
7 Omreport storage commands........................................................................147
8 Omconfig storage commands....................................................................... 157
6
7
8
9 Working With CLI Command Results...........................................................210
9
10
1
Introduction
Dell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution through either an integrated Web browser-based graphical user interface (GUI) or a command line interface (CLI). Server Administrator is designed for system administrators to manage systems locally and remotely on a network. It allows system administrators to manage their entire network by providing a comprehensive one-to-one systems management.
In the context of Server Administrator, a system refers to a stand-alone system, a system with attached network storage units in a separate chassis, or a Blade system consisting of one or more server modules in a modular enclosure.
Server Administrator provides easy-to-use management and administration of local and remote systems through a comprehensive set of integrated management services. Server Administrator is the sole installation on the system being managed and is accessible both locally and remotely from the Server
Administrator home page. Server Administrator enables you to access remotely monitored systems by dial-in, LAN, or wireless connections.
The configuration features enable Server Administrator to perform essential tasks described in detail in the following sections. This CLI guide documents all the commands that apply to Server Administrator and Storage Management.
The reporting and viewing features enable retrieval of the overall health status for systems on the network. You can view information about voltage, temperature, fan's revolutions per minute (RPM), memory functioning, and many other critical details at the component level. You can also see a detailed account of the cost of ownership (COO) about the system, retrieve version information about the BIOS, firmware, operating system, and all installed software.
NOTE: The CLI does not use the Server Administrator Web server. For concerns on encryption, from the CLI, run the omconfig system webserver action=stop command to turn off the Web server. The
Web server starts automatically after a reboot, so you must run this command each time the system
NOTE: After installing Dell OpenManage Server Administrator, ensure that you log out and log in to reset the path to access Dell OpenManage CLI utilities.
NOTE: For information on terms used in this document, see the Glossary at dell.com/support/ manuals.
What is new in this release
The release highlights of OpenManage Server Administrator are:
• Added support for the following feature in Server Administrator:
– New CLI commands for configuring and displaying the SNMP Test Trap: omconfig system
snmptraptest and omreport system snmptrapdest. For more details, see Omconfig system snmptratest and
.
• Added support for the following features in Storage Administrator:
– New CLI command for configuring the Disk Cache Policy for Non-RAID Hard disk drives: omconfig storage controller action=setchangecontrollerproperties controller=<value> nrdiskcachepolicy=<attribute>. For more information, see
.
– New CLI command for configuring the Disk Cache for physical disk: omconfig storage pdisk
Controller=<value> action=setarraydiskcache cache=<attribute> pdisk=<value>. For more information, see
Omconfig physical disk commands
• Added support for the following operating systems:
– Red Hat Enterprise Linux 7.2
– SUSE Linux Enterprise Server 12 SP1
– VMware vSphere 6.0 U1
• Added support for the following browsers:
– Google Chrome 45
– Mozilla Firefox 40
NOTE: For the list of supported operating systems and Dell servers, see the Dell Systems Software
Support Matrix in the required version of OpenManage Software at dell.com/openmanagemanuals.
NOTE: CLI commands are not supported on systems running the VMware ESXi operating system.
Accessing the windows command prompt to run CLI commands
If you are running the Microsoft Windows operating system, use the 32-bit command prompt to run a
Server Administrator CLI command. Access the 32-bit command prompt using one of the following methods:
• Click Start → Programs → Accessories → Command Prompt.
• Click Start → Run and type cmd.exe.
NOTE: Do not type command in the Run dialog box to launch a command line window; this activates the MS-DOS emulator command.com, which has environment variable limitations that can cause subtle problems with CLI.
Primary CLI Commands
The commands that carry out the functions of Server Administrator are:
• omconfig
• omhelp
• omreport
The omconfig command writes values that you assign to an object's properties. You can specify values for warning thresholds on components or prescribe actions that the system must perform when a certain warning or failure event occurs. You can also use the omconfig command to assign specific values to the
11
system's asset information parameters, such as the purchase price of the system, the system's asset tag, or the system's location.
The omhelp command displays short-text help for CLI commands. The shorthand equivalent of omhelp is the command for which you want help followed by -?. For example, to display help for the omreport command, type one of the following commands:
• omhelp omreport
• omreport -?
The omreport command displays reports of the management information of the system.
NOTE: For an overall summary of the CLI commands, type omhelp.
NOTE: The omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or the Server Update Utility commands. To update the different components, download the Dell Update Package and run the <package name> /s [/f command. For more information on the corresponding CLI syntax, see the Dell Update Packages
for Operating Systems User’s Guide or the Dell OpenManage Server Update Utility User’s Guide at dell.com/support/manuals.
Related Links: Working With CLI Command Results
CLI error checking and error messages
When you type CLI commands, the CLI checks these commands for the correct syntax. If you type a command and the command is executed successfully, a message is displayed, stating that the command is successful.
Success Messages
When you type a successful omconfig command, data for that component is displayed.
The following omconfig command examples displays valid CLI commands and their success messages:
Table 1. Commands And Messages
Command omconfig chassis temps index=0 warnthresh= default omconfig chassis biossetup attribute=numlock setting=on omconfig system assetinfo info=depreciation duration=6
Message
Temperature probe warning threshold value(s) set successfully.
BIOS setup configured successfully.
Change will take effect after the next reboot.
omconfig system assetinfo info=depreciation duration=6
Failure Messages
CLI failure messages provide reasons why some commands do not succeed. Some common reasons why commands fail include syntax errors and components that are not present. Many error messages provide syntax information required to execute the command successfully.
12
If you execute a command for a component or feature that is not present in the system configuration, the error message states that the component is not present.
The following are examples of some failure messages:
Command
Message omconfig chassis volts index=3 minwarnthresh=3.3000
Error! Number with up to 3 digits after decimal point expected, read 3.3000
The value given by the command specifies more than 3 digits after the decimal point. A valid minimum warning threshold value for volts contains up to 3 digits after the decimal point.
Revised command omconfig chassis volts index=3 minwarnthresh=3.300
When you type the revised command with three decimal points, you receive another error message:
Message Error! This voltage probe min warning threshold must be between 11.400 and 12.480.
Revised command omconfig chassis volts index=3 minwarnthresh=11.500
Message Voltage probe warning threshold(s) set successfully.
Scripting And Comparing Using CLI
The Server Administrator CLI allows administrators to write batch programs for the operating system. For an enterprise with many systems, an administrator could write a configuration script that specifies the warning thresholds for each major component of a system and also specifies a set of actions that the administrator wants each system to take in case of a warning or failure event. In most critical cases, the administrator could write a script so that the system shuts down to prevent damage. The administrator could then distribute and execute the script to many managed systems at the same time. Such a scenario facilitates configuring any number of new systems acquired by a company and makes implementation of new system administration policies easier across many existing systems that require re-configuration.
A similar scenario is used to populate a large number of newly acquired systems with detailed asset information. Much of the information are the same, such as the manufacturer or lessor of the system, whether support for the system is outsourced, name of the company providing insurance for the system, method of depreciation, and so on. Any variable that is common to all systems is scripted, sent to all managed systems, and executed. Asset information that is unique to a system is scripted as a group and sent to that managed node for execution. For example, a script could specify values for all unique variables such as the owner, primary user phone number, asset tag, and so on. Scripts to populate unique values would set all unique variables at once rather than one by one through the system's command line.
In many cases, the CLI allows a user with a very well-defined task in mind to retrieve information about the system rapidly. If a user wants to review a comprehensive summary of all system components and save that summary information to a file for comparison with later system states, the CLI is ideal.
Using CLI commands, administrators can write batch programs or scripts to execute at specific times.
When these programs are executed, they can capture reports on components of interest, such as fan
RPMs during periods of highest system usage compared with the same measurements at times of lowest system usage. Command results are routed to a file for later analysis. Reports can help administrators
13
gain information that are used to adjust usage patterns, to justify purchasing new system resources, or to focus on the health of a problem component.
Command syntax overview
Commands vary in complexity. The simplest command has only command level 1. The omhelp command is a simple command. When you type omhelp, a list of the main CLI commands is displayed.
The next level of complexity includes commands that contain command levels 1 and 2. All of the about commands are examples of command level 2 complexity. The omconfig about and omreport about commands display a very brief summary. The summary shows version information for the systems management software installed on the system; for example, Server Administrator 1.x.
Some commands have command level 1 and command level 2 and one name=value pair. Consider the following example command that instructs Server Administrator for more details about the environment for Server Administrator: omreport about details=true
In this example, command level 1 is omreport, command level 2 is about, and the name= value pair is details=true.
Many commands use command level 1, command level 2, and command level 3, but do not require any parameters (name=value pairs). Most omreport commands are of this type. For example, the following command displays a list of alert actions that are configured for components on a system.
omreport system alertaction
The most complex commands have all three command levels and can have multiple name=value pairs.
The following is an example of two name=value pairs: omconfig system assetinfo info=depreciation duration=3
The following is an example of nine name=value pairs: omconfig system assetinfo info=acquisition purchasecost=<n> waybill=<n> installdate=<mmddyy> purchasedate=<mmddyy> ponum=<n> signauth=<text> expensed=<yes>|no> costcenter=<text>
In each chapter of this document, command syntax and other information about the commands are formatted using any of the following fields as appropriate: command level 1 command level 2 command level 3 name=value pair 1 name=value pair 2
14
2
Using The omhelp Command
The omhelp command and its equivalent, <command> -?, accesses the detailed help-text interface of
Command Line Interface (CLI). You can get help at several levels of detail.
Each fully-qualified CLI command may have a variable number of distinct parts: the command
(command level 1), one or more subcommands (command level 2 and command level 3, if present), and one or more name= value pair(s).
By appending -?(space-dash-question mark) to any command, you can get help for that command.
Example Help Commands
When you type omconfig -?, you get general help about the omconfig command. The help at this level lists the available subcommands for omconfig:
• about
• preferences
• chassis
• system
When you type omconfig system -?, the CLI help lists all the subcommands available for omconfig system:
• alertaction
• alertlog
• assetinfo
• cmdlog
• esmlog
• events
• platformevents
• pedestinations
• recovery
• shutdown
• thrmshutdown
• webserver
Also parse the omconfig system assetinfo command as follows:
<command level 1 command level 2 command level 3> <name=value pair 1>
[name=value pair 2]
15
where command levels 1, 2, and 3 are represented by omconfig system assetinfo, name=value pair 1 is represented by info=depreciation , and name=value pair 2 is represented by method=straightline.
To set the depreciation method to straight line, type: omconfig system assetinfo info=depreciation method=straightline
The CLI responds with the following message:
Asset information set successfully.
When you type omconfig system assetinfo -?, the help that displays provides information about assigning values for the name and option fields. Partial results for the request omconfig system assetinfo
-? are as follows: assetinfo Set asset information.
For one info value, specify one or more optional parameter(s).
The following table displays the optional parameters for info=acquisition:
Table 2. Optional Parameters
Info Value
Info=acquisition
Optional parameters purchasecost=<num> waybill <num>installdate
=<mmddyy> purchasedate=<mmddyy> ponum=<num> signauth=<text> expensed=<yes|
no> costcenter=<text> info=depreciation method=<text> duration= <num> percent=<percent> unit=<months | years |
unknown>
16
omreport: Viewing System Status Using
The Instrumentation Service
3
The omreport command allows you to see detailed information about the system components. You can also retrieve summaries for many system components at one time, or get details about a specific component. This chapter shows you how to get reports with the level of detail that you want.
Commands documented in this chapter vary in whether they define the fields that appear in the results of a particular omreport command. The fields are defined only if they have a special or less familiar use.
As with all other components, use omreport to view component status, and omconfig to manage a
component. For information on configuring components for management, see omconfig: Managing
Components Using The Instrumentation Service
.
Use the omreport commands to get information you need to execute an omconfig command. For example, to edit the minimum temperature for a warning event on a temperature probe, you must know the index of the probe you want to configure. Use omreport chassis temps to display a list of probes and their indexes.
The omreport commands available on the system depend on the system configuration. The following table lists the systems on which the omreport commands are applicable:
Table 3. System Availability For The omreport Command
Command
Level 1 omreport
Command
Level 2 modularenclos ure
Applicable To servermodule Blade systems mainsystem Blade systems system chassis preferences
Blade systems
Rack and Tower systems
Rack and Tower systems
Blade or Rack, and Tower systems
Conventions for parameter tables
When listing the parameters that a command can take, the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface.
17
The symbol |, often called pipe, is the logical exclusive or operator. For example, enable | disable means you can enable or disable the component or feature, but you cannot simultaneously enable and disable the component or feature.
Command summary of the omreport command
Depending on the system configuration, the results of the omreport command vary from one system to another. Data displays for installed components only.
NOTE: When a system includes an external chassis, the displayed results vary by operating system.
On SUSE Linux Enterprise Server and Red Hat Enterprise Linux systems, the omreport commands display external chassis information in a separate section after the main chassis information. On
Microsoft Windows systems, data about the external chassis does not appear in the omreport output.
The following table provides a high-level summary of the omreport command. The column titled
Command level 1 displays the omreport command at its most general use. Command level 2 shows the major objects or components that you can view using omreport (about, chassis, storage, and system).
Command level 3 lists the specific objects and components to view reports. User privilege required refers to the type of privilege you need to run the command, where U = User, P = Power User, and A =
Administrator. Use is a very general statement about the actions performed using omreport.
The following table lists the omreport commands available for about, system, and main system chassis.
Table 4. Command Level 1, Level 2, And Level 3 For omreport
Command
Level 1
CommandLevel
2 omreport modularenclosur e about chassis or mainsystem
Command Level 3 User
Privilege
Required
U, P, A
Use
Displays the information for all the modular chassis.
U, P, A details=true U, P, A
Displays the version number and properties for Server Administrator.
Displays the information for all the
Server Administrator programs installed.
acswitch
U, P, A
U, P, A
Displays the general status of all the main components.
Displays the failover settings where redundant AC power lines are supported in a system.
batteries bios biossetup fans
U, P, A
U, P, A
A
U, P, A
Displays the properties set for batteries.
Displays the BIOS information such as manufacturer, version, and release date.
Displays the BIOS setup properties configured during system boot.
Displays the status and thresholds for system fans.
18
Command
Level 1
CommandLevel
2
Command Level 3 User
Privilege
Required firmware U, P, A
Use
Displays the name and version of the firmware.
frontpanel U, P, A Displays whether the front panel button settings, such as the Power button and/or Nonmasking Interrupt (NMI) button (if present on the system), are enabled or disabled. It also displays the front panel encryption access information and the front panel LCD information.
fru U, P, A hwperformance info intrusion leds
U, P, A
U, P, A
U, P, A
U, P, A
Displays the Field Replaceable Unit (FRU) information.
Displays the status and cause for the system’s performance degradation.
Displays a status summary for main system chassis components.
Displays the status of the system’s intrusion sensor(s).
Displays the properties you have set for light-emitting diodes to flash under various alert conditions.
memory U, P, A nics ports processors pwrmanagement pwrmonitoring pwrsupplies
U, P, A
U, P, A
U, P, A
U, P, A
U, P, A
U, P, A
Displays properties of the system's memory arrays.
Displays the NIC and Team interface properties.
Displays the properties for the system’s parallel and serial ports, such as I/O address, IRQ level, connector type, and maximum speed.
Displays properties of the system’s processors, including speed, manufacturer, and processor family.
Displays power inventory details such as system idle power, system maximum potential power, and power budget information.
Displays properties of power consumption.
Displays the properties of power supplies.
19
Command
Level 1
CommandLevel
2 licenses storage system or servermodule
Command Level 3 User
Privilege
Required remoteaccess U, P, A
Use
Displays general information on remote access.
slots U, P, A temps U, P, A
Displays the properties of the system’s expansion slots and other slot types.
Displays the status and thresholds for the system temperature sensors.
volts U, P, A removableflashme dia
U, P, A
U, P, A
U, P, A
Displays the status and thresholds for the system voltage sensors.
Displays the system’s virtual flash (vFlash) and secure digital (SD) card details.
Displays the digital licenses of the installed hardware devices of the system.
See
U, P, A alertaction alertlog assetinfo cmdlog esmlog events
U, P, A
U, P, A
U, P, A
U, P, A
U, P, A
U, P, A
Displays a high-level summary of system components.
Displays the warning and failure threshold values, as well as actions configured when an essential component detects a warning or failure state.
Allows the administrator to display the alert log.
Displays the cost of ownership information for the system.
Allows the administrator to display the command log.
Allows the administrator to display the hardware log.
Displays the system’s Simple Network
Management Protocol (SNMP) event settings.
operatingsystem U, P, A pedestinations platformevents
U, P, A
U, P, A
Displays the name and version of the operating system.
Displays the destinations to send the configured alerts for platform events.
Displays the system’s response for each listed platform event
20
Command
Level 1
CommandLevel
2 preferences
Command Level 3 User
Privilege
Required recovery P, A
Use
Displays how the system is configured to respond to a hung operating system.
shutdown P, A summary U, P, A
Displays how to perform the shutdown action.
Displays the key facts for all system components, including main system chassis, software, and storage.
thrmshutdown P, A version webserver messages
U, P, A
U, P, A
A
Displays how to perform the shutdown action, if any, when a temperature warning or failure condition is detected.
Displays a summary for all updatable components on the system.
Displays the URL information of the
Server Administrator Web server.
Displays the configured alert message format.
Related Links: omreport: Viewing System Status Using The Instrumentation Service
Help With The omreport Command
Use the omreport -? command to get a list of the available commands for omreport.
Use omreport <command level 2> -? to get help on the level 2 about, chassis, and system commands.
The following information on omreport system -? also applies to get help for the omreport chassis command.
To see a list of valid commands for omreport system, type: omreport system -? | more
omreport modularenclosure
Use the omreport modularenclosure command to view details of the Blade system. Type: omreport modularenclosure
NOTE: This CLI command is available when Dell OpenManage Server Administrator is installed on
Dell Blade systems.
Server Administrator displays information related to the modular enclosure and chassis management controller CMC (if available):
NOTE: The output varies depending on the configuration of the system.
21
Modular Chassis Information
Chassis Information
Attribute
Value
Attribute
Value
Attribute
Value
Attribute
Value
CMC Information
Attribute
Value
Attribute
Value
: Model
: Modular Server Enclosure
: Lock
: true
: Service Tag
: 8RLNB1S
: Express Service Code
: 18955029124
Attribute
Value
Attribute
Value
Attribute
Value
Attribute
Value
Attribute
Value
: Product
: Chassis Management Controller (CMC)
: Description
: The system component provides a complete set of remote managementfunctions for Dell systems.
: Version
: 3.20
: IP Address
: 101.102.103.104
: IP Address Source
: Dynamic Source
: IP Address Type
: IPv4
: Remote Connect Interface
: Launch CMC Web Interface
omreport about
Use the omreport about command to learn the product name and version number of the systems management application installed on the system. The following is an example output from the omreport about command:
Product name
Version
: Dell OpenManage Server Administrator
: x.x.x
22
Copyright
Company
: Copyright (C) Dell Inc. xxxx-xxxx. All rights reserved.
: Dell Inc.
For details about the environment for Server Administrator, type: omreport about details=true
Server Administrator includes a number of services, each of which has a version number of its own. The
Contains field reports version numbers for the services as well as other useful details. The following output is an example, and can change depending on the system’s configuration and the version of Server
Administrator installed on the system:
Contains: Instrumentation Service 7.x.x
Storage Management 4.x.x
Sun Java Runtime Environment 1.x.x_xx
Secure Port Server 7.x.x
Server Administrator Core Files 7.x.x
Instrumentation Service Integration Layer 7.x.x
Server Administrator Common Framework 7.x.x
Common Storage Module 4.x.x
Data Engine 7.x.x
Instrumentation Service 7.x.x
Omreport Chassis Or Omreport Mainsystem Commands
Use the omreport chassis or omreport mainsystem commands to view details for the entire chassis or for a particular component. Type: omreport chassis or omreport mainsystem
Server Administrator displays a general status for the main system chassis or main system components.
Health
Main System Chassis
SEVERITY
Ok
Critical
Ok
Ok
Ok
Ok
: COMPONENT
: Fans
: Intrusion
: Memory
: Power Supplies
: Temperatures
: Voltages
23
Chassis management
On servers with Dell PowerEdge FX2 series chassis, when Chassis Management at Server Mode is set to
Monitor or Manage and Monitor in CMC, OMSA displays Chassis Management at Server Mode as
Enabled and displays the Fans, Power Supplies, and Temperature sensor details. The sensor details are read-only. When Chassis Management at Server Mode is set to None in CMC, OMSA displays Chassis
Management at Server Mode as Disabled and displays only the server temperature sensors (not chassis temperature sensors).
Related Links
•
omreport chassis fans or omreport mainsystem fans
•
omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
•
omreport chassis temps or omreport mainsystem temps
Omreport chassis acswitch or omreport mainsystem acswitch
Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that are configured in a failover arrangement. Type: omreport chassis acswitch or omreport mainsystem acswitch
Server Administrator displays the following output:
AC Failover Switch
AC Switch Redundancy
Redundancy Status
Number of devices required for full redundancy
Redundancy Mode
Redundancy Configuration
: Full
: 2
:
: Input Source Line 1, upon redundancy restoration, return to Line 1
AC Power Lines
Status
Location
AC Present
Active Source
Status
Location
AC Present
: Ok
: AC Power Line 1
: Power Present
: Active
: Ok
: AC Power Line 2
: Power Present
24
Active Source : Not Active
Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.
Omreport Chassis Batteries Or Omreport Mainsystem Batteries
Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties. Type: omreport chassis batteries or omreport mainsystem batteries
Omreport Chassis Bios Or Omreport Mainsystem Bios
Use the omreport chassis bios or omreport mainsystem bios command to view the current BIOS information. Type: omreport chassis bios or omreport mainsystem bios
Server Administrator displays the summary of the BIOS information for the system.
Omreport chassis biossetup or omreport mainsystem biossetup
Use the omreport chassis biossetup or omreport mainsystem biossetup command to view BIOS setup parameters that are normally available only during system boot. Type: omreport chassis biossetup or omreport mainsystem biossetup
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
To view the BIOS Setup parameters in short form, type: omreport chassis biossetup display=shortnames
To view all available boot devices, alias names, and boot order sequences, type: omreport chassis biossetup attribute=bootorder
NOTE: The bootorder attribute is applicable only on systems prior to 12G. To list the device boot order, type omreport chassis biossetup and serach the list under BIOS Boot Settings or UEFI
Boot Settings depending on the BIOS boot setting.
NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot view the boot order sequence.
To list the device boot order, type omreport chassis biossetup and search the list under BIOS
Boot Settings or UEFI Boot Settings depending on the BIOS boot setting.
25
NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot view the boot order sequence.
BIOS setup groups
The following table lists the available groups of the BIOS setup parameters on PowerEdge systems.
NOTE: Based on the hardware configuration, the attributes may vary in a specific group.
Table 5. BIOS Setup Groups
Group
BIOS Option Settings
Boot Settings
Integrated Devices
Memory Settings
Miscellaneous Settings
Network Settings
One-Time Boot
NOTE: This group is not supported on 13G systems.
Description
Controls the BIOS start settings when bootmode is set to bios.
Controls the system boot settings when bootmode is set to bios.
Controls the devices integrated on the system board.
Controls the system memory settings.
Controls some miscellaneous system settings.
Controls the network settings of the system.
Supports one-time boot to a specified device.
Processor Settings
SATA Settings
Serial Communication
Slot Disablement
System Information
System Profile Settings
System Security
UEFI Boot Settings
Controls the processor settings of the system.
Control the embedded SATA ports settings.
Controls the Serial Communication options.
Controls the system slots that are present on the system.
Displays the information that uniquely identifies the system.
Controls the power management settings.
Controls the security features of the system.
Controls the system boot settings when boot mode is set to uefi.
Omreport Chassis Currents Or Omreport Mainsystem Currents
This command is no longer available through Server Administrator.
Omreport chassis fans or omreport mainsystem fans
Use the omreport chassis fans or omreport mainsystem fans command to view the fan probe status and settings. Type: omreport chassis fans index=n or omreport mainsystem fans index=n
26
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any fan probes that are present on the system. If you specify the index, Server Administrator displays a summary for a specific fan probe.
NOTE: On servers in the Dell PowerEdge FX2 series chassis, this command is supported only if the
Chassis Management at Server Mode is set to either Monitor or Manage and Monitor in the CMC, and Server Administrator displays the Chassis Management at Server Mode as Enabled. For more
details, see Chassis Management
.
Omreport Chassis Firmware Or Omreport Mainsystem Firmware
Use the omreport chassis firmware or omreport mainsystem firmware command to view current firmware properties. When you type: omreport chassis firmware or omreport mainsystem firmware
Server Administrator displays a summary of the system’s firmware properties.
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server Administrator displays the Unified Server Configurator (USC) version.
Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel
Use the omreport chassis frontpanel or omreport mainsystem frontpanel command to view if the front panel button control settings, such as the Power button and/or Nonmasking Interrupt (NMI) button (if present on the system), are enabled or disabled.
If the Power button override is present on the system, check whether the Power button override is enabled or not. If enabled, the Power button turns the power to the system On and Off.
If the NMI button is present on the system, check whether the NMI button is enabled or not. Use the NMI button to troubleshoot software and device errors when using certain operating systems.
The Front Panel LCD Security Access displays if the front panel encryption access information is set to
View, Modify, or Disable.
The Front Panel LCD Information displays information such as service tag, remote indication status, and so on.
Omreport Chassis Fru Or Omreport Mainsystem Fru
Use the omreport chassis fru or omreport mainsystem fru command to view FRU information. When you type: omreport chassis fru or omreport mainsystem fru
27
Server Administrator displays a summary of the system’s FRU information. This information is available in the Server Administrator GUI, SNMP, and Common Information Model and is primarily used to support troubleshooting activities.
Omreport chassis hwperformance or omreport mainsystem hwperformance
Use the omreport chassis hwperformance or omreport mainsystem hwperformance command to view the status and cause for the system’s performance degradation. When you type: omreport chassis hwperformance or omreport chassis hwperformance
Server Administrator displays a summary of the system’s hardware performance degradation information.
NOTE: This command is applicable only to selected Dell 10G systems that support PMBus.
Depending on the system’s configuration, you may notice the following output:
Hardware Performance
Index
Probe Name
Status
Cause
: 0
: System Board Power Optimized
: Normal
: [N/A]
Omreport Chassis Info Or Omreport Mainsystem Info
Use the omreport chassis info or omreport mainsystem info command to see a summary of installed component versions. Type: omreport chassis info index=n or omreport mainsystem info index=n
The index parameter specifies a chassis number and is optional. If you do not specify the index, Server
Administrator displays summary chassis information for each chassis. If you specify the index, Server
Administrator displays summary information for a specific chassis.
NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server Administrator displays the USC version.
Depending on the system’s configuration, you may notice the following output:
Index
Chassis Name
Host Name iDRAC7 Version
Chassis Model
: 0
: Main System Chassis
: WIN-27C02UQFV6L
: 1.00
: PowerEdge R720
28
Chassis Lock
Chassis Service Tag
Express Service Code
Chassis Asset Tag
: Present
: 7654321
: 15608862073
: c
Omreport Chassis Intrusion
Use the omreport chassis intrusion command to find out whether the cover of the system is open or not.
Server Administrator tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component, or to perform unauthorized maintenance on the system. Type: omreport chassis intrusion
A message that resembles the following is displayed:
Intrusion Information
Health
Index
Status
Probe Name
State
: Ok
: 0
: OK
: Intrusion
: Chassis is closed
Omreport Chassis Leds Or Omreport Mainsystem Leds
Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard drive fault is supported and what severity level lights up the LED. Type: omreport chassis leds index=n or omreport mainsystem leds index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of LED information for chassis 0. If you specify the index, Server Administrator displays a summary for a specific chassis.
The following is an example output:
Main System Chassis
Flash chassis identify LED state : Off
Flash chassis identify LED timeout value : 300
29
Omreport Chassis Memory Or Omreport Mainsystem Memory
Use the omreport chassis memory or omreport mainsystem memory to view details for each memory module slot in the system. If the system supports redundant memory, this command also displays the status, state, and type of memory redundancy implemented on the system. Type: omreport chassis memory index=n or omreport mainsystem index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays information for all memory modules on the system as follows:
The following is an example output:
Memory Information
: Ok Health
Attributes of Memory Array(s)
Location
Use
Installed Capacity
Maximum Capacity
Slots Available
Slots Used
Error Correction
Total of Memory Array(s)
Total Installed Capacity
Total Installed Capacity Available to the OS
Total Maximum Capacity
Details of Memory Array 1
Index
Status
Status
Status
Connector Name
: System Board or Motherboard
: System memory
: 65536 MB
: 786432 MB
: 24
: 8
: Multibit ECC
: 65536 MB
: 64386 MB
: 786432 MB
: 0
: Ok
: Ok
: Ok
: DIMM_A1
30
Type
Size
Index
Status
Connector Name
Type
Size
Index
Status
Connector Name
Type
Size
Index
Status
Connector Name
Type
: DDR3 - Synchronous Registered
(Buffered)
: 8192 MB
: 1
: Ok
: DIMM_A2
: DDR3 - Synchronous Registered
(Buffered)
: 8192 MB
: 2
: Ok
: DIMM_A3
: DDR3 - Synchronous Registered
(Buffered)
: 8192 MB
: 3
: Ok
: DIMM_A4
: DDR3 - Synchronous Registered
(Buffered)
: 8192 MB Size
If you specify the index, Server Administrator displays a summary for a specific memory module displaying the health, status, device name, type, speed, rank, and failures. A rank is a row of dynamic random access memory (DRAM) devices comprising 64 bits of data per Dual Inline Memory Module
(DIMM). The possible values of rank are single, dual, quad, octal, and hexa. The rank displays the rank of the DIMM and helps in the easy service of DIMMs on the server.
The following is an example output if you specify the index:
Memory Device Information
Health : Ok
Status
Device Name
Size
Type
: Ok
: DIMM_A1
: 8192 MB
: DDR3 Synchronous Registered (Buffered)
31
Speed
Rank
Failures
: 0.75 ns
: Dual
: None
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. Change the user scripts as applicable.
Omreport chassis nics or omreport mainsystem nics
Use the omreport chassis nics or omreport mainsystem nics command to view NIC and Team interface details. On XenServer, the command displays all the installed NICs, regardless of driver installation.
NOTE: The order in which devices are detected is not guaranteed to match the physical port ordering of the device.
To view NIC properties, type: omreport chassis nics index=n or omreport chassis nics index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays properties of all NICs on the system and the values for the following fields: Index (NIC card number), Interface
Name, Vendor, Description, Connection Status, and Slot.
If you specify the index, Server Administrator displays properties for a specific NIC and the values for the following fields: Physical Interface, Interface, IPv4 Addresses, IPv6 Addresses, Physical Interface Receive
Statistics, Physical Interface Transmit Statistics, Interface Receive Statistics, and Interface Transmit
Statistics.
NOTE: The Fibre Channel over Ethernet (FCoE) and iSCSI over Ethernet (iSCSI Offload Engine) features of Converged Network Adapter (CNA) cards are not supported on VMware ESX and
VMware ESXi systems.
To view Team interface properties, type: omreport chassis nics config=team index=n or omreport mainsystem nics config=team index=n
NOTE: This command is applicable only if Team interface is configured in the system. Team interface is configured using NIC vendor tools, such as Broadcom.
NOTE: On systems running Linux operating systems with kernel versions earlier than 3.10, Team
Interface speed is not displayed.
The index parameter is optional. If you do not specify the index, Server Administrator displays details of all the Team interfaces on the system and the values for the following fields: Index (NIC card number),
Interface Name, Vendor, Description, and Redundancy Status.
If you specify the index, Server Administrator displays the Team interface details for the specific NIC and the values for the following fields: Team Interface, Interface, IPv4 Addresses, IPv6 Addresses , Team
32
Interface Receive Statistics , Team Interface Transmit Statistics , Interface Receive Statistics, and Interface
Transmit Statistics.
Omreport Chassis Ports Or omreport Mainsystem Ports
Use the omreport chassis ports or omreport mainsystem ports command to view properties of the system’s parallel and serial ports.
NOTE: CMC USB ports attached with blade servers are not enumerated by OMSA.
Server Administrator displays values for the following fields: Port Type, External Name, Base I/O Address,
IRQ Level, Connector Type, and Maximum Speed. The following table provides the description of the fields:
Table 6. Fields and Description
Field Description
Port Type Detailed type of each system port, from the more general serial, parallel, and USB ports to the names of ports by device type connected to it, for example, pointing device or keyboard.
Name of the port, such as serial or parallel, USB, mouse, keyboard, and so on.
External
Name
Base I/O
Address
Starting I/O address expressed in hexadecimal.
IRQ Level Hardware interrupt on a system. The hardware interrupt signals the system's CPU that an event has started or ended in a peripheral component such as a modem or printer. When communicated over a peripheral component interconnect card, the IRQ level is a standard way to identify the type of device that is sending the interrupt request.
Connector
Type
Type of plug or cable and plug that connects two devices together, in this case, the type of connector that attaches an external device to a system. There are many connector types, each designed to connect a different device type to a system. Examples include DB-9
Male, AT, Access Bus, PS/2, and so on.
Maximum
Speed
Port speed. Port speed refers to the data transmission rate of an input/output channel, measured in numbers of bits per second. Serial ports usually have a maximum speed of 115
Kbps and USB version 1.x ports have a maximum speed of 12 Kbps.
Omreport Chassis Processors Or Omreport Mainsystem Processors
Use the omreport chassis processors or omreport mainsystem processors command to view properties of the system’s processors.
Server Administrator displays values for the following fields: Index, Status, Connector Name, Processor
Brand, Processor Version, Current Speed, State, and Core Count.
The following table provides the description of the fields.
33
Table 7. Fields and Description
Field
Index
Status
Connector
Name
Description
Processor number
Current status of the processor.
Name or number of the device that occupies the processor slot in the system.
Processor Brand Type of processor made by a manufacturer such as Intel Itanium, Intel Pentium III,
Intel Xeon, or AMD Opteron.
Processor
Version
Model and stepping number of the processor.
Current Speed Actual processor speed in MHz at system boot time.
State Whether the processor slot is enabled or disabled.
Core Count Number of processors integrated into one chip.
Capabilities and cache properties of a specific processor
To view the cache properties of a processor on a given connector, type: omreport chassis processors index=n or omreport mainsystem processors index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all processors. If you specify the index, Server Administrator displays properties for a specific processor.
The following table lists the fields that are defined for the capabilities present on a particular microprocessor:
Table 8. Microprocessors and Fields
Microprocessor
Intel Processor
Fields
• 64-bit Support
• Hyperthreading (HT)
• Virtualization Technology (VT)
• Demand-Based Switching (DBS)
• Execute Disable (XD)
• Turbo Mode
AMD Processor • 64-bit Support
• AMD-V
• AMD PowerNow!
• No Execute (NX)
The following fields are defined for a cache present on a particular microprocessor. If the cache is internal to the processor, the fields do not appear in the cache report:
34
• Speed
• Cache Device Supported Type
• Cache Device Current Type
• External Socket Name
The following table displays the fields that are displayed for each cache on a particular processor:
Table 9. Fields And Description
Field
Status
Level
Speed
Max Size
Installed Size
Type
Location
Write Policy
Description
Reports whether a specific cache on the processor is enabled or disabled.
Refers to a primary or secondary cache. Primary-level cache is a memory bank built into the processor. Secondary-level cache is a staging area that feeds the primary cache. A secondary-level cache is built into the processor or resides in a memory chipset outside the processor. The internal processor cache is referred to as a Level 1 (or
L1). L2 cache is the external cache in a system with an Intel Pentium processor, and it is the second level of cache that is accessed. The names L1 and L2 are not indicative of where the cache is physically located (internal or external), but describe which cache is accessed first
(L1, therefore internal).
Refers to the rate at which the cache can forward data from the main memory to the processor.
Maximum amount of memory that the cache can hold in kilobytes.
Actual size of the cache.
Indicates whether the cache is primary or secondary.
Location of the cache on the processor or on a chipset outside the processor.
Describes how the cache deals with a write cycle. In a write-back policy, the cache acts like a buffer. When the processor starts a write cycle, the cache receives the data and stops the cycle. The cache then writes the data back to the main memory when the system bus is available.
In a write-through policy, the processor writes through the cache to the main memory. The write cycle does not complete until the data is stored into the main memory.
Associativity Refers to the way in which main memory content is stored on the cache.
• A fully associative cache allows any line in main memory to store at any location in the cache.
• A n-way set-associative cache directly maps n specific lines of memory to the same n lines of cache. For example, line 0 of any page in memory is stored in line 0 of cache memory.
Cache Device Supported
Type
Type of static random access memory (SRAM) that the device can support.
35
Field
Cache Device Current Type
External Socket Name Silk
Screen Name
Error Correction Type
Description
Type of the currently installed SRAM that the cache is supporting.
Name printed on the system board next to the socket.
Identifies the type of error checking and correction (ECC) that this memory can perform. Examples are correctable ECC or uncorrectable
ECC.
Omreport chassis pwrmanagement or omreport mainsystem pwrmanagement
Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view the power budget cap and power management profiles of the system. The values display either in Watts or BTU/Hr based on the configuration. Type: omreport chassis pwrmanagement or omreport mainsystem pwrmanagement
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.
NOTE: The omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command is applicable on PowerEdge 11G systems that support Power Management Bus (PMBus) and that have hot-swappable power supplies and not systems that have a fixed, non-redundant power supply installed.
The output of the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command lists each of the valid parameters. The following table lists the available settings.
Table 10. Valid Parameters Of Omreport Chassis Pwrmanagement Or Omreport Mainsystem
Pwrmanagement name=value pair unit=<watt | btuphr>
Description
Displays power in the user-specified units.
config=budget config=profile
Displays power budget information.
Displays power profiles information.
NOTE: On PowerEdge 12G systems, profile option is SysProfile and is grouped under
System Profile Settings of the BIOS setup group. For more information, see
Settings on PowerEdge 12G systems
.
For each power management profile in the system, values display for the following fields: Maximum
Performance, Active Power Controller, OS Control, and Custom.
36
The Custom attributes are: CPU Power and Performance Management, Memory Power and Performance
Management, and Fan Power and Performance Management.
The following is an example output:
Power Inventory and Budget
Power Inventory
System Idle Power
System Maximum Potential Power
: 92 W
: 344 W
Power Budget
Attribute
Values
Attribute
Values
: Enable Power Cap
: Enabled
: Power Cap
: 400 W (56%)
NOTE: Power budget requires license to report the details. If the appropriate license is not installed or has expired, the system does not display the power budget details. For more information, see the
Dell License Manager Guide at dell.com/support/manuals.
Omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring
Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the properties of the system’s power consumption. The values display either in Watts or BTU/Hr based on the configuration. Type: omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring
For each power monitoring profile in the system, values display for the following fields:
• Power Consumption Status
• Probe Name
• Reading
• Warning Threshold
• Failure Threshold
• Amperage: Location and Reading
• Power Tracking Statistics
• Energy Consumption
• Measurement Start Time
• Measurement Finish Time
• Reading
• System Peak Power
37
• System Peak Amperage
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system onwards that support PMBus and that have hot-swappable power supplies and not systems that have a fixed, non-redundant power supply installed.
NOTE: Power monitoring requires license to report the details. If the appropriate license is not installed or has expired, the system does not display the power consumption details of the system.
For more information, see the Dell License Manager at Guide dell.com/openmanagemanuals.
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.
An example output reporting power statistics in Watts is as follows:
Power Consumption Information
Power Consumption
Index
Status
Probe Name
Reading
Warning Threshold
Failure Threshold
Amperage
PS1 Current 1
Power Headroom
System Instantaneous Headroom
System Peak Headroom
Power Tracking Statistics
Statistic
Measurement Start Time
Measurement Finish Time
Reading
Statistics
Measurement Start Time
Peak Time
Peak Reading
Statistics
Measured Since
: 1
: Ok
: System Board Pwr Consumption
: 539W
: 994W
: 1400 W
: 1.2 A
: 300 W
: 340 W
: Energy consumption
: Thu May 28 11:03:20 2011
: Fri May 28 11:05:46 2011
: 5.9 KWH
: System Peak Power
: Mon May 18 16:03:20 2011
: Wed May 27 00:23:46 2011
: 630 W
: System Peak Amperage
: Mon May 18 16:03:20 2011
38
Read Time
Peak Reading
: Tue May 19 04:06:32 2011
: 2.5 A
NOTE: Power Management features are only available for PowerEdge systems that have hotswappable power supplies and not systems that have a fixed, non-redundant power supply installed.
Omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties of the system’s power supplies. Type: omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
NOTE: On servers in the Dell PowerEdge FX2 series chassis, this command is supported only if the
Chassis Management at Server Mode is set to either Monitor or Manage and Monitor in the CMC, and Server Administrator displays the Chassis Management at Server Mode as Enabled. For more
details, see Chassis Management
.
For each power supply profile in the system, the values for the following fields are displayed:
• Status
• Location
• Type
• Rated Input Wattage (in Watts)
• Maximum Output Wattage
• Online Status
• Power Monitoring Capable
Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information on baseboard management controller or integrated Dell remote access controller
(BMC/iDRAC) and remote access controller if DRAC is installed. Type: omreport chassis remoteaccess or omreport mainsystem remoteaccess
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.
The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists each of the valid parameters as displayed in the following table:
39
Table 11. Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess name=value pair config=additional config=advsol config=nic config=serial config=serialoverla n config=terminalmo de config=user
Description
Reports the current state of IPv4 and IPv6 addresses on iDRAC.
Reports advanced BMC/iDRAC or remote access information on a serial over local area network (LAN) connection.
Reports BMC/iDRAC or remote access information for the LAN.
Reports serial port information for BMC or remote access.
Reports BMC/iDRAC or remote access information on a serial over LAN connection.
Reports terminal mode settings for the serial port.
Reports information on BMC/iDRAC or remote access users.
Omreport Chassis Removableflashmedia Or Omreport Mainsystem
Removableflashmedia
Use the omreport chassis removableflashmedia or omreport mainsystem removableflashmedia to view the removable flash media details on the system along with its health status. Type: omreport chassis removableflashmedia or omreport mainsystem removableflashmedia
Server Administrator displays a summary of the system’s removable flash media information.
NOTE: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.
Depending on the configuration of the system, you may notice the following output:
Removable Flash Media Information
Health
Internal Dual SD Module Redundancy
Attribute
Value
Internal SD Modules Status
Status
Connector Name
State
: Critical
: Critical
: Redundancy
: Lost
: OK
: System Board SD Status 1
: Present
Storage Size
Status
: 512 MB
: OK
40
Connector Name
State
Storage Size
VFlash Media Details
Connector Name
Type
State
Available Size
Storage Size
: System Board SD Status 2
: Present
: 512 MB
: System Board SD Status 1
: vFlash SD Card
: Present
: 472 MB
: 512 MB
Omreport Chassis Slots Or Omreport Mainsystem Slots
Use the omreport chassis slots or omreport mainsystem slots command to view properties of the system’s slots. Type: omreport chassis slots index=n or omreport mainsystem slots index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all of the slots in the system. If you specify the index, Server Administrator displays properties for a specific slot.
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
For each slot in the system, values display for the following fields given in the following table:
Table 12. Valid Parameters Of Omreport Chassis Slots Or Omreport Mainsystem Slots
Field
Index
Slot ID
Adapter
Data Bus
Width
Description
Number of the slot in the system.
Silk screen name printed on the system's motherboard next to the slot. Alphanumeric text uniquely identifies each slot in the system.
Name and/or type of the card that fits into the slot, for example, a storage array controller,
SCSI adapter, iDRAC Enterprise, or HBA.
Width, in bits, of the information pathway between the components of a system. The range of the data bus width is from 16 to 64 bits.
Omreport chassis temps or Omreport mainsystem temps
Use the omreport chassis temps or omreport mainsystem temps command to view properties of the system’s temperature probes. Type: omreport chassis temps index=n
41
or omreport mainsystem temps index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any temperature probes that are present on the system. If you specify the index, Server Administrator displays the summary for a specific temperature probe.
NOTE: On servers in the Dell PowerEdge FX2 series chassis, this command is supported only if the
Chassis Management at Server Mode is set to either Monitor or Manage and Monitor in the CMC, and Server Administrator displays the Chassis Management at Server Mode as Enabled. For more
details, see Chassis Management
.
Omreport Chassis Volts Or Omreport Mainsystem Volts
Use the omreport chassis volts or omreport mainsystem volts command to view properties of the system’s voltage probes. Type: omreport chassis volts index=n or omreport mainsystem volts index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any voltage probes that are present on the system. If you specify the index, Server Administrator displays a summary for a specific voltage probe.
Omreport Licenses
Use the omreport licenses command to view the digital licenses of the hardware devices installed on the system. Type: omreport licenses
The following is an example output from the omreport licenses command:
Device Index
Device Status
Device
Device Description
Device ID
License Index
Description
Status
Recommended Action
License Type
EntitlementID
: 0
: Ok
: iDRAC7
: iDRAC
: xxxx
: 0
: iDRAC7 Enterprise Evaluation License
: OK
: N/A
: Evaluation
: xxxx
42
Expiry Date : yyyy-mm-dd hh:mm:ss
Omreport System Commands Or Omreport
Servermodule Commands
Use the omreport system or omreport servermodule commands to view logs, threshold values, cost of ownership information, and information about how shutdown actions and recovery actions are configured.
Omreport System Or Omreport Servermodule
Use the omreport system or omreport servermodule command to see a general status of the components of the system. When you specify a level 3 command, such as omreport system shutdown or omreport servermodule shutdown, you get detailed information for one system component rather than the high-level status obtained with omreport system or omreport servermodule. Type: omreport system or omreport servermodule
If the system has both a main system chassis or main system and at least one direct attached storage device, Server Administrator may display a summary that resembles the following example:
SEVERITY : COMPONENT
Ok : Main System Chassis
Critical : Storage
Commands for viewing logs
Use the omreport system or omreport servermodule command to view the following logs: the alert log, the command log, and the hardware or ESM log.
NOTE: If the Alert log or Command log displays invalid XML data (such as when XML data generated for the selection is not well-formed), you must clear the log and resolve the issue. To clear the log, type: omconfig system alertlog action=clear or omconfig system cmdlog action=clear. If you need to retain the log information for future reference, save a copy of the
log before clearing. For more information about clearing logs, see Commands For Clearing Logs .
To view the contents of the alert log, type: omreport system alertlog or omreport servermodule alertlog
To view the contents of the command log, type: omreport system cmdlog
43
or omreport servermodule cmdlog
To view the contents of the ESM log, type: omreport system esmlog or omreport servermodule esmlog
Overall Health Status Of The ESM Log
When you run the omreport system esmlog or omreport servermodule esmlog command, the ESM log is displayed. The first line of the report reflects the overall health of the system hardware. For example,
Health: OK means that less than 80 percent of the space allotted for the ESM log is occupied by messages. If 80 percent or more of the allotted space for the ESM log is occupied, the following caution is displayed:
Health: Non-Critical
If a caution is displayed, resolve all warning and critical severity conditions, and then clear the log.
Omreport System Alertaction Or Omreport Servermodule Alertaction
Use the omreport system alertaction or omreport servermodule alertaction command to view a summary of alert actions that have been configured for warning and failure events on the system components.
Alert actions determine how Server Administrator responds when a component has a warning or failure event.
The omreport system alertaction or omreport servermodule alertaction command is useful for viewing which alert actions have been specified for components. To set an alert action for a component, use the omconfig system alertaction or omconfig servermodule alertaction command. For more information, see
omconfig: Managing Components Using The Instrumentation Service .
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
Components and events having view alert actions
View alert action properties for the following components and events, if the components or events are present on the system:
• Battery Warning
• Battery Failure
• Chassis Intrusion
• Current Probe Warning
• Current Probe Failure
• Fan Warning
• Fan Failure
• Memory Pre-failure
• Memory Failure
• System Power Probe Warning
• System Power Probe Detects a Failure
44
• System Peak Power
• Power Supply Warning
• Power Supply Failure
• Degraded Redundancy
• Lost Redundancy
• Temperature Warning
• Temperature Failure
• Voltage Warning
• Voltage Failure
• Processor Warning
• Processor Failure
• Hardware Log Warning
• Hardware Log Full
• Watchdog Asr
• Storage System Warning
• Storage System Failure
• Storage Controller Warning
• Storage Controller Failure
• Physical Disk Warning
• Physical Disk Failure
• Virtual Disk Warning
• Virtual Disk Failure
• Enclosure Warning
• Enclosure Failure
• Storage Controller Battery Warning
• Storage Controller Battery Failure
• Removable Flash Media Present
• Removable Flash Media Removed
• Removable Flash Media Failure
NOTE: Storage Controller Battery Warning and Storage Controller Battery Failure events are not available on blade systems.
NOTE: System Power Probe Warning is not applicable to blade systems.
Omreport System Assetinfo Or Omreport Servermodule Assetinfo
Use the omreport system assetinfo or omreport servermodule assetinfo command to see cost of ownership data for the system, such as acquisition, depreciation, and warranty information. To set any of these fields, use the omconfig system assetinfo or omconfig servermodule assetinfo command. For more information, see
Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership Values .
45
Omreport system events or omreport servermodule events
Use the omreport system events or omreport servermodule events command to view the currently enabled or disabled SNMP traps. Type: omreport system events or omreport servermodule events
This command displays a summary of each component in the system for which events are generated. For each component, the report shows which severities are set to report and which severities are set not to report. The following is an example output for a few components:
Current SNMP Trap Configuration
-----------
System
-----------
Settings
Enable: Informational, Warning and Critical
Disable: None
---------------
Power Supplies
----------------
Settings
Enable: Informational, Warning and Critical
Disable: None
-----------
Fans
-----------
Settings
Enable: Critical
Disable: Informational, Warning, and Critical
---------------------
Removable Flash Media
---------------------
Settings
Enable: Informational, Warning and Critical
Disable: None
The full report lists the settings for all components in the system for which events are generated.
Omreport System Events Type Or Omreport Servermodule Events Type
To view the status for components of a specific type, use the omreport system events type=<component name> or omreport servermodule event type=<component name> command. Type: omreport system events type=fans or omreport servermodule events type=fans
This command displays a summary of each component in the system for which events are generated.
The following table displays the events displayed for various component types.
46
Table 13. Valid Parameters Of Omreport System Events Type Or Omreport Servermodule Events Type name=value pair type=accords type=battery type=fanenclosures type=fans type=intrusion type=log type=memory type=powersupplies type=redundancy type=systempower type=temps type=removableflashmedia type=volts
Description
Reports events for AC power cords
Reports events for batteries
Reports events for fan enclosures
Reports events for fans
Reports events for chassis intrusion
Reports events for logs
Reports events for memory
Reports events for power supplies
Reports events for redundancy
Reports events for system power
Reports events for temperatures
Reports events for removable flash media
Reports events for voltages
The following is an example output:
Current SNMP Trap Configuration
-------
System
-------
Settings
Enable: Informational, Warning, and Critical
Disable: None
-----------
Fans Group
----------
Settings
Enable: Informational, Warning, and Critical
Disable: None
-----------
Individual Objects
-----------
System Board Fan1 RPM Settings
Index:0
Enable: Informational, Warning, and Critical
Disable: None
System Board Fan2 RPM Settings
Index:1
Enable: Informational, Warning, and Critical
Disable: None
Omreport System snmptrapdest Or Omreport Servermodule snmptrapdest
Use the omreport system snmptrapdest or omreport servermodule snmptrapdest command to view the configured SNMP trap destinations.
47
When the system is configured with the IP destinations, the following list of IP address is displayed:
Destination1 : <ip address1>
Destination2 : <ip address2>
Destination3 : <ip address3>
Omreport System Operatingsystem Or Omreport Servermodule
Operatingsystem
Use the omreport system operatingsystem or omreport servermodule operatingsystem command to display information about the operating system.
Omreport System Pedestinations Or Omreport Servermodule Pedestinations
Use the omreport system pedestinations or omreport servermodule pedestinations command to view destinations where alerts are sent for platform events. Depending on the number of destinations displayed, configure a separate IP address for each destination address. Type: omreport system pedestinations or omreport servermodule pedestinations
The output of the omreport system pedestinations or omreport servermodule pedestinations command lists each of the valid parameters.
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
Destination configuration settings for the Omreport system pedestinations or Omreport servermodule pedestinations
The actual number of destinations that you can configure on a system using omreport system pedestinations or omreport servermodule pedestinations may differ.
The following table displays the available settings.
Table 14. Settings For The Omreport System Pedestinations Or Omreport Servermodule Pedestinations
Output
Destination List
Attributes Description
Destination Number:
Destination1 destination 1: Displays the first destination.
Example:
101.102.103.104: IPv4 address of the first destination.
Destination Number:
Destination 2
Destination Number:
Destination 3 destination 2: Displays the second destination.
Example:
110.120.130.140: IPv4 address of the second destination.
destination 3: Displays the third destination.
Example:
48
Output Attributes
Destination Number:
Destination 4
Destination Number:
Destination 5
Destination Number:
Destination 6
Destination Number:
Destination 7
Destination Number:
Destination 8
Description
201:202:203:204: IPv4 address of the third destination.
destination 4: Displays the fourth destination.
Example:
210.211.212.213: IPv4 address of the fourth destination.
destination 5: Displays the fifth destination.
Example:
2001:0db8:85a3:0000:0000:8a2e:0370:7334: IPv6 address of the fifth destination.
destination 6: Displays the sixth destination.
Example:
2001:0db8:85a3:0000:0000:8a2e:0370:7334: IPv6 address of the sixth destination.
destination 7: Displays the seventh destination.
Example:
210.211.212.213: IP address of the seventh destination.
destination 8: Displays the eighth destination.
Example:
210.211.212.213: IP address of the eighth destination.
Destination
Configuration Settings attribute=communityst ring communitystring: Displays the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station
.
NOTE: On 12G systems with iDRAC7 specific versions, ipaddress can also be a Fully Qualified
Domain Name (FQDN).
Omreport System Platformevents Or Omreport Servermodule
Platformevents
Use the omreport system platformevents or omreport servermodule platformevents command to view how the system responds for each listed platform event.
49
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.
Omreport System Recovery Or Omreport Servermodule Recovery
Use the omreport system recovery or omreport servermodule recovery command to see whether there is an action configured for a hung operating system. You can also view the number of seconds that must elapse before an operating system is considered hung.
Omreport System Shutdown Or Omreport Servermodule Shutdown
Use the omreport system shutdown or omreport servermodule shutdown command to view any pending shutdown actions for the system. If properties for shutdown are configured, executing this command displays these properties.
Omreport System Summary Or Omreport Servermodule Summary
Use the omreport system summary or omreport servermodule summarycommand to view a comprehensive summary of software and hardware components currently installed on the system. Type: omreport system summary or omreport servermodule summary
NOTE: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.
NOTE: If iDRAC is installed, Server Administrator displays the LCC version. If BMC is installed, Server
Administrator displays the USC version.
The output that is displayed in the CLI window depends on the systems management software, operating system, and hardware components and options installed on the system. The following partial command results are unique and may not resemble the hardware and software configuration of the system:
System Summary
-----------------
Software Profile
-----------------
Systems Management
Name
Version
Description
Contains
: Dell OpenManage Systems Management Software (64–
Bit)
: x.x.x
: Systems Management Software
Apache Tomcat Webserver x.x.x
: Common Storage Module x.x.x
: Data Engine x.x.x
50
Operating System
Name
Version
System Time
System Bootup Time
-------
Server Module
-------
Information
Host Name
System Location
Model
Asset Tag
Service Tag
Express Service Code
: Hardware Application Programming Interface x.x.x
: Instrumentation Servicex.x.x
: Instrumentation Service Integration Layer x.x.x
Intel SNMP Agent x.x.x
: Inventory Collector x.x.x
: OMACS x.x.x
: Operating System Loggingx.x.x
: Oracle Java Runtime Environment x.x.x
: Remote Access Controller Managed Node x.x.x
: Server Administrator Common Framework x.x.x
: Server Administrator Core files x.x.x
: Server Administrator Instrumentation files x.x.x
: Server Administrator Core files x.x.x
: Server Instrumentation SNMP Module x.x.x
: Server Instrumentation WMI Module x.x.x
: Storage Management x.x.x
: Microsoft Windows Server 2008 R2, Enterprise x64
Edition
: Version 6.1 (Build 7601 : Service Pack 1) (x64)
Server Full Installation
: Fri May 20 18:02:52 2XXX
: Wed May 18 18:37:58 2XXX
: WIN-GSFCCED6N2D
: Please set the value
: PowerEdge FM120
SST,3,4,S
CB2DX1S
26790524560
51
Slot Number
Slot Name
Form Factor
Node Id
Slot =8
SLOT-02
1U Half Width
CB2DX1Sc
Remote Access Information
Remote Access Device vFlash Media
: iDRAC7 Express
: Absent
Processor 1
Processor Brand
Processor Version
Voltage
: Genuine Intel (R) CPU 4000 @ 2.41GHz
: Model 77
: 1000 mV
Memory
Total Installed Capacity :4096 MB
Memory Available to the OS :4096 MB
Total Maximum Capacity
Memory Array Count
:32768 MB
: 1
Memory Array 1
Location
Use
Installed Capacity
Maximum Capacity
Slots Available
Slots Used
ECC Type
: System Board or Motherboard
: System Memory
: 4096 MB
: 32768 MB
: 24
: 1
: Multibit ECC
BIOS Information
Manufacturer
Version
Release Date
Firmware Information
Name
Version
: Dell Inc.
: 0.1.10
: 07/31/2013
: iDRAC7
: 1.50.50 (Build 3)
52
Firmware Information
Name
Version
---------------
Remote Access Controller
---------------
Remote Access Controller
Information
Product
IP Address
IP Subnet
IP Gateway
IPv6 Address 1
IPv6 Address 2
IPv6 Gateway
---------------
Network Data
---------------
Network Interface 0
IP Address
Subnet Mask
Default Gateway
MAC Address
Network Interface 1
IP Address
Subnet Mask
Default Gateway
MAC Address
: Lifecycle Controller 2
: 1.3.0.518
: iDRAC7 Express
: 10.94.146.217
: 255.255.255.0
: 10.94.146.1
: ::
: ::
: ::
: xx.xx.xx.xx
: xx.xx.xx.xx
: xx.xx.xx.xx
: : xx-xx-xx-xx-xx-xx
: xx.xx.xx.xx
: xx.xx.xx.xx
: xx.xx.xx.xx
: : xx-xx-xx-xx-xx-xx
Hardware Information Using Omreport System Summary Or Omreport Servermodule
Summary
The system summary hardware information includes data values for installed components of the following types present in the system:
System Attributes
53
• Host Name
• System Location
• Life Cycle Controller
Main System Chassis Or Main System
Chassis
• Chassis Model
• Chassis Service Tag
• Express Service Code
• Chassis Lock
• Chassis Asset Tag
Remote Access
Information
Processor
• Remote Access Device
• vFlash Media
• vFlash Media Size
The following are listed for each processor in the system:
• Processor Brand
• Processor Family
• Processor Version
• Current Speed
• Maximum Speed
• External Clock Speed
• Voltage
Memory
• Total Installed Capacity
• Memory Available to the Operating System
• Total Maximum Capacity
• Memory Array Count
Memory Array
The following details are listed for each memory board or module in the system
(for example, the system board or the memory module in a given slot number):
• Location
• Use
• Installed Capacity
• Maximum Capacity
• Slots Available
• Slots Used
• ECC Type
BIOS
• Manufacturer
• BIOS Version
54
• Release Date
Firmware
• Name
• Version
Network Data
The following details are listed for each NIC and Team interface, if Team interface is configured in the system:
• IP Address
• Subnet Mask
• Default Gateway
• MAC Address
Storage Enclosures
The following details are listed for each storage enclosure attached to the system:
• Name
• Service Tag
Omreport System Thrmshutdown Or Omreport Servermodule
Thrmshutdown
Use the omreport system thrmshutdown or omreport servermodule thrmshutdown command to view the properties configured for a thermal shutdown action.
The three properties that display for thermal shutdown are disabled, warning, or failure. If the CLI displays the following message, the thermal shutdown feature has been disabled:
Thermal protect shutdown severity: disabled
If the system is configured to shutdown when a temperature probe detects a warning or failure event, one of the following messages is displayed:
Thermal protect shutdown severity: warning
Thermal protect shutdown severity: failure
Omreport System Version Or Omreport Servermodule Version
Use the omreport system version or omreport servermodule version command to list the version numbers of the BIOS, firmware, systems management software, and operating system installed on the system. Type: omreport system version or omreport servermodule version
NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server Administrator displays the USC version.
55
The output that is displayed in the CLI window depends on the version of the BIOS, RAID controllers, and firmware installed on the system. The following partial command results are unique and may not resemble the results for the configuration of the system:
Version Report
---------------------
Main System Chassis
---------------------
Name : BIOS
Version : 0.3.5
Name : iDRAC7
Version : 1.00
---------------------
Software
---------------------
Name : Microsoft Windows Server 2008 R2, Enterprise x64 edition
Version : Version 6.1 (Build 7600) (x64) Server Full Installation
Name : Dell Server Administrator
Version : 7.x.x
------------------------------------
Storage Controller Firmware
------------------------------------
Name : PERC H310 Mini
Version : 20.10.1-0025
Omreport Preferences Commands
Use the omreport preferences command to view the URL details of the Server Administrator Web server, key sign algorithm, JRE, and message format.
Omreport Preferences Messages
Use the omreport preferences messages to view the configured alert message format.
The following table lists the available attributes of omreport preferences messages.
Table 15. Valid Parameters Of Omreport Preferences Messages name=value pair Description attribute=format Reports the currently configured alert message format.
Type: omreport preferences messages attribute=format
The output that is displayed is as follows:
Event Message Format : enhanced
Omreport preferences logging
Use the omreport preferences logging command to view the log details.
The following table lists the available attributes of omreport preferences logging.
56
Table 16. Valid Parameters Of Omreport Preferences Logging name=value pair attribute=oslogfilter attribute=archiveesmlog
Description
Displays the settings configured for OS logging filter.
Displays the settings for Auto Archive ESM Log preference.
Type: omreport preferences logging attribute=oslogfilter
The output that is displayed is as follows:
Log Critical : false
Log Warning : true
Log Informational : true
Omreport preferences webserver
Use the omreport preferences webserver command to view the URL details, current key-sign algorithm, and the JRE details.
The following table lists the available attributes of omreport preferences webserver.
Table 17. Valid Parameters Of Omreport Preferences Webserver name=value pair attribute=geturl attribute=getsignalgorithm attribute=getjre attribute=getjrelist attribute=getciphers attribute=getsslprotocol attribute=getport attribute=getipaddress attribute=getsessiontimeout
Description
Reports the URL information of the web server. This command helps to access the Server Administrator GUI using a remote web server (management system).
Reports the current key-sign algorithm.
Displays the version of the currently used JRE.
Displays the supported JRE versions installed in the system.
Displays the current cipher values configured.
Displays the current SSL Protocol values set.
Displays the information of the configured port value.
Reports the configured IP Address value.
Displays the configured session time-out value.
Type: omreport preferences webserver attribute=getjrelist
The output that is displayed is as follows:
Version: 1.7.0_05 (Bundled)
Path : C:\Program Files <x86>\Dell|SysMgt\jre
Version:1.7.0_03
Path:C:\Program Files <x86>\Java\jre7
57
58
4
Omconfig: Managing Components Using
The Instrumentation Service
The omconfig command allows you to provide values that define warning events, configure alert actions, clear logs, and configure system shutdown, as well as perform other systems management tasks.
Examples of omconfig capabilities include:
• Administrator privilege to clear command, alert, and hardware logs
• Administrator privilege to configure and execute system shutdown
• Power user and administrator privilege to specify values for warning events on fans, voltage probes, and temperature probes
• Power user and administrator privilege to set alert actions in case of a warning or failure event from intrusion, fans, voltage probes, and temperature probes
For more information on using the omconfig command to view and manage cost of ownership information (assetinfo), see
Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership
.
Often, you must use the omreport commands to get the information required to execute an omconfig command. For example, to edit the minimum temperature for a warning event on a temperature probe, you must know the index of the probe. Use the omreport chassis temps or omreport mainsystem temp command to display a list of probes and their indexes. For more information on using the omreport command, see
Omreport: Viewing System Status Using The Instrumentation Service .
The following table displays the system availability for the omconfig command:
Table 18. System Availability For The Omconfig Command
Command Level 1 omconfig
Command Level 2 servermodule mainsystem system chassis
Applicable to
Blade systems
Blade systems
Rack and Tower systems
Rack and Tower systems
Conventions for parameter tables
When listing the parameters that a command can take, the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface.
The symbol |, often called pipe, is the logical exclusive or operator. For example, enable | disable means you can enable or disable the component or feature, but you cannot simultaneously enable and disable the component or feature.
omconfig Command Summary
The following table provides a high-level summary of the omconfig command. The columns titled
Command level 2 and Command level 3 list the major arguments that are used with omconfig. User
privilege required refers to the type of privilege you need to run the command, where U = User, P =
Power User, and A = Administrator. Use is a very general statement about the actions that are performed using omconfig.
NOTE: Although the following table lists all possible omconfig commands, the commands available on the system depend on the system configuration. If you try to get help or run a command for a component not installed on the system, Server Administrator displays a message that the component or feature is not found on the system.
NOTE: When CSIOR (Collect System Inventory on Restart) is disabled, omconfig does not allow to configure the BIOS settings.
Table 19. omconfig Command Level 1, Level 2, and Level 3
Comman d Level 1
Command
Level 2
Command
Level 3
User
Privilege
Required
Use omconfig about details=true
U, P, A
U, P, A
Shows the version number and properties for the Server Administrator program.
Displays information for all Server Administrator programs that are installed.
preferences cdvformat dirservice messages useraccess webserver
A
A
A
A
A
Specifies the delimiter for separating data fields reported in custom delimited format (cdv).
Configures the Microsoft Active Directory service.
Displays the configured alert message format.
Determines whether users below the administrator level are allowed to use Server
Administrator or not.
Allows the administrator to set the encryption levels of the Web server and configure the URL launch point in the Server Administrator Web server environment.
system or servermodule
59
Comman d Level 1
Command
Level 2
Command
Level 3 alertaction alertlog assetinfo cmdlog esmlog events
P, A
P, A pedestinations P, A platformevent s
A recovery shutdown thrmshutdow n webserver
User
Privilege
Required
P, A
Use
P, A
P, A
P, A
P, A
A
A
A
Determines in advance the actions taken for warning or failure events on intrusion, fans, temperatures, voltages, power supplies, memory, and redundancy.
Allows the administrator to clear the alert log.
Enters and edits cost of ownership information for the system, including values for depreciation, lease, maintenance, service, and support.
Allows the administrator to clear the command log.
Allows the administrator to clear the ESM log.
Enables or disables SNMP traps.
Sets IP addresses for alert destinations.
Determines the shutdown action, if any, taken for a specific platform event. Also, enables or disables platform events filter alert generation.
Determines in advance how the system responds to a hung operating system.
Allows the administrator to select from several options when shutting down the system.
Sets the severity level at which a thermal event triggers a system shutdown.
Starts or stops the Web server.
chassis or mainsystem biossetup fans frontpanel info
A
P, A
A
P, A
Configures the behavior of specific system components controlled by the BIOS.
Configures fan probe warning thresholds to the default or a specific value.
NOTE: You cannot change threshold values on embedded server management (ESM3) and Dell PowerEdge x8xx systems.
Configures the Power button, Non-Masking
Interrupt (NMI) button, encryption access, and
LCD display of the system.
Allows you to set an initial value, or to edit the value of the asset tag or chassis name.
60
Comman d Level 1
Command
Level 2 storage
Command
Level 3 leds memorymode A pwrmanagem ent pwrmonitorin g
User
Privilege
Required
P, A
Use
P, A
P, A remoteaccess A temps P, A
Specifies when to flash a chassis fault LED or chassis identification LED, and allows you to clear the LED for the system's hard drive.
Enables or disables the spare bank, mirroring, raid, and Double Device Data Correction
(DDDC) memory modes, and also specify which mode to use.
Allows you to choose between maximum power, economy, and optimized performance of the system.
Configures power consumption information and thresholds.
Configures remote access information.
Sets warning threshold values to the default or a specific value.
NOTE: You cannot change threshold values on ESM3 and PowerEdge x8xx systems.
volts P, A Sets warning threshold values to the default or a specific value.
NOTE: You cannot change threshold values on ESM3 and PowerEdge x8xx systems.
For more information, see
Help With The Omconfig Command
The following table lists the usage of omconfig commands.
Table 20. Usage Of Omconfig Commands
Command Usage omconfig -?
omconfig <command level 2> -?
omconfig chassis -?
omconfig system -?
Description
To display the list of the available commands for omconfig.
To display the help for about, chassis, preferences, and system’s level 2 commands.
To display the help for omconfig chassis command.
To display the help for omconfig system command.
omconfig preferences
-?
To display the available commands for omconfig preferences, such as cdvformat, which is the custom delimiter format (cdv).
omconfig preferences cdvformat -?
To display the list of delimiter values for the cdv.
61
Command Usage omconfig system
<command level 3> -?
Description
To display the list of the parameters you must use to execute a particular omconfig system command.
To display the list of valid parameters for omconfig system alertaction.
omconfig system alertaction -?
omconfig system shutdown -?
To display the list of valid parameters for omconfig system shutdown.
omconfig system alertaction -? | more omconfig system alertaction -? -outa alert.txt
more alert.txt
To display the list of valid parameters for omconfig system alertaction and to scroll the command output one screen at a time. Here, | more allows you to press the spacebar to see the next screen of the CLI help output.
To create a file that contains all the help for the omconfig system alertaction -? command. Here, -outa directs the output of the command to a file called alert.txt .
To read the help for the alertaction command on Microsoft Windows, Red Hat
Enterprise Linux, or SUSE Linux Enterprise Server operating systems.
Omconfig About
Use the omconfig about command to learn the product name and version number of the systems management application installed on the system. The following is an example output of the omconfig about command:
Product name
: Dell OpenManage Server Administrator
Version : 7.x.x
Copyright : Copyright (C) Dell Inc. xxxx-xxxx. All rights reserved.
Company : Dell Inc.
For more details about the environment for Server Administrator, type: omconfig about details=true
Server Administrator includes a number of services, each having a version number of its own. The
Contains field reports version numbers for the services and provides other useful details. The output may change depending on the configuration of the system and the version of Server Administrator.
Contains: Broadcom SNMP Agent 10.xx.xx
Common Storage Module 3.x.x
Data Engine 5.x.x
Hardware Application Programming Interface 5.x.x
Instrumentation Service 6.x.x
Instrumentation Service Integration Layer 1.x.x
Intel SNMP Agent 1.xx.x
62
OpenManage Inventory Collector 6.x.x
OpenManage Tools 6.x.x
Remote Access Controller 4 Data Populator 4.x.x
Remote Access Controller 4 Managed Node 4.6.3
Secure Port Server 1.x.x
Server Administrator Framework 6.x.x
Agent for Remote Access 1.x.x
Storage Management 3.x.x
Sun Java Runtime Environment 1.x.xx
Omconfig Chassis Or Omconfig Mainsystem
Use the omconfig chassis or omconfig mainsystem commands to:
• Set to default or assign specific values for fan, voltage, and temperature probes
• Configure BIOS behavior during system start up
• Clear memory error counts
• Enable or disable power button control features if the system configuration permits
Use the omconfig chassis -? or omconfig mainsystem -? command to view a list of all omconfig chassis or omconfig mainsystem commands.
Omconfig Chassis Biossetup Or Omconfig Mainsystem Biossetup
Use the omconfig chassis biossetup or omconfig mainsystem biossetup command to configure system
BIOS settings that are normally available only in the BIOS setup boot time settings of the system.
CAUTION: Changing certain BIOS setup options may disable the system or require you to reinstall the operating system.
NOTE: Reboot the system for the BIOS setup options to take effect.
NOTE: Not all BIOS setup options are available on every system.
NOTE: When CSIOR (Collect System Inventory on Restart) is disabled, you cannot configure the
BIOS settings using omconfig command.
BIOS setup settings on systems prior to PowerEdge 12G systems
The following table displays the name=value pairs that you can use with omconfig chassis biossetup or omconfig mainsystem biossetup command on systems prior to PowerEdge 12G systems.
Table 21. BIOS Setup Settings on systems prior to PowerEdge 12G systems name=value pair 1 attribute= attribute=acpwrrecovery name=value pair 2 setting= setting=off | last| on
Description
• off: System is turned off.
• last: System returns to the previous state.
63
name=value pair 1 attribute= attribute=bezel attribute=bootsequence attribute=bootmode attribute=bootorder attribute=hddorder name=value pair 2 setting= delay=random | immediate | timedelay <value> setting=enabled | disabled setting=diskettefirst | hdonly | devicelist | cdromfirst | opticaldrive setting=uefi | bios sequence=aliasname1, aliasname2,..... aliasnameN sequence=aliasname1, aliasname2,..... aliasnameN
Description
• on: System is turned on.
• random: System is turned on with random delay.
• immediate: System returns to previous state immediately.
• timedelay <value>: System is turned on based on the user specified time delay.
• enabled: Enables the bezel removal intrusion check during system boot.
• disabled: Disables the bezel removal intrusion check during system boot.
Instructs the BIOS which device is used to boot the system, and the order in which the boot routine checks each device.
NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting.
• uefi: Enables the system to boot to operating systems that support Unified
Extensible Firmware Interface
(UEFI).
• bios: Enables the system to boot to operating systems that do not support UEFI.
Configures the boot sequence according to the set aliasnames.
To view the set alias names, run the command omreport chassis biossetup attribute=bootorder
NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting.
Configures the BIOS setup hard disk sequence according to the set aliasnames. Changes takes effect after rebooting the system.
64
name=value pair 1 attribute= attribute=cstates attribute=conredirect attribute=cpucle attribute=cpuht attribute=cpuvt attribute=cpuxdsupport attribute=cpucore name=value pair 2 setting= setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled
Description
To view the set alias names, run the command omreport chassis biossetup attribute=bootorder
NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting.
• enabled: Enables the processor to go into a deep sleep state when the system is not utilized.
• disabled: Disables the processor to go into a deep sleep state when the system is not utilized.
• enabled: Redirects the BIOS screen output over serial port
1. Keyboard and text output are redirected over serial port
2.
• disabled: Turns off the BIOS console redirection.
• enabled: Enables processor
C1-E after system reboot.
• disabled: Disables processor
C1-E after system reboot.
• enabled: Enables logical processor hyperthreading.
• disabled: Disables logical processor hyperthreading.
• enabled: Enables virtualization.
• disabled: Disables virtualization.
• enabled: Enables Execute
Disable (XD) support on the system.
• disabled: Disables XD support on system.
setting=1 | 2 | 4 | 6 | 8 | 10 | 12 |all • 1: Enables one core per processor.
• 2: Enables two cores per processor.
• 4: Enables four cores per processor.
65
name=value pair 1 attribute= attribute=dbs attribute=diskette attribute=dualnic name=value pair 2 setting= Description
• 6: Enables six cores per processor.
• 8: Enables eight cores per processor.
• 10: Enables ten cores per processor.
• 12: Enables twelve cores per processor.
• all: Enables the maximum cores per processor.
setting=enable | disable • enable: Enables Demand
Based Switching (DBS) on the system.
• disable: Disables DBS on the system.
setting=off | auto | writeprotect • off: Disables the diskette drive.
• auto: Auto-enables the diskette drive.
• writeprotect: The diskette drive is available in read-only format only. Makes the diskette drive read-only.
setting=off | on | pxeboth | nic1pxe |nic2pxe | isciboth | nic1isci | nic2isci | nic1pxenic2isci
| nic1iscinic2pxe | onpxeboth | onpxenone | onpxenic1 | onpxenic2
• off: Disables the Network
Interface Controllers (NICs).
• on: Enables the network interface (PXE or iSCSI is not enabled on either of the
NICs).
• pxeboth: Enables PXE on both NICs.
• nic1pxe: Enables PXE on the first NIC and none (no PXE or iSCSI) on the second NIC.
• nic2pxe: Enables none (no
PXE or iSCSI) on first NIC and
PXE on the second NIC.
• isciboth: Enables iSCSI on both the NICs.
• nic1isci: Enables iSCSI on the first NIC and none (no PXE or iSCSI) on the second NIC.
• nic2isci: Enables none (no
PXE or iSCSI) on the first NIC and iSCSI on the second NIC.
• nic1pxenic2isci: Enables PXE on the first NIC and iSCSI on second NIC.
• nic1iscinic2pxe: Enables iSCSI on the first NIC and PXE on second NIC.
66
name=value pair 1 attribute= attribute=embhypvisor attribute=embvideoctrl attribute=esataport attribute=extserial attribute=fbr attribute=htassist name=value pair 2 setting= setting=enabled | disabled setting=enabled | disabled setting=off | auto setting=com1 | com2 | rad setting=9600 | 19200 | 57600 |
115200 setting=enabled | disabled
Description
The following options are deprecated:
• onpxeboth: Enables PXE on both the NICs.
• onpxenone: PXE is not enabled on either of the NICs.
• onpxenic1: Enables PXE on
NIC 1.
• onpxenic2: Enables PXE on
NIC 2.
• enabled: Enables the embedded hypervisor.
• disabled: Disables the embedded hypervisor.
• enabled: Enables the embedded video controller as the primary video device.
• disabled: Disables the embedded video controller as the primary video device.
• off: Sets the embedded SATA port value to off.
• auto: Sets the embedded
SATA port value to auto.
• com1: Maps the external serial connector to COM 1.
• com2: Maps the external serial connector to COM 2.
• rad: Maps the external serial connector to the remote access device.
• 9600: Sets the console redirection failsafe baud rate to 9600 bits per second.
• 19200: Sets the console redirection failsafe baud rate to 19200 bits per second.
• 57600: Sets the console redirection failsafe baud rate to 57600 bits per second.
• 115200: Sets the console redirection failsafe baud rate to 115200 bits per second.
• enabled: Enables the probe filter chipset option.
• disabled: Disables the probe filter chipset option.
67
name=value pair 1 attribute= attribute=ide attribute=idepridrv attribute=intrusion attribute=mouse attribute=nic1 attribute=nic2 name=value pair 2 setting= setting=on | off force=true
Description
NOTE: Certain applications do not function fully if you enable or disable this option.
• on: Enables IDE.
• off: Disables IDE.
• force=true: Verification of setting change.
setting=off | auto setting=enabled | disabled setting=on | off
• off: Disables the device.
• auto: Detects and enables the device automatically.
• enabled: Enables the intrusion check during system boot. If the system also has bezel intrusion checking, then the intrusion option checks for removal of the bezel of the system.
• disabled: Disables the intrusion check during system boot.
• on: Enables the mouse.
• off: Disables the mouse.
setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi
• enabled: Enables the first NIC during system boot.
• enabledwithpxe: Enables the first NIC during system boot
(with PXE on if the system has
PXE).
• disabled: Disables the first
NIC during system boot.
• enabledonly: Enables the first
NIC during system boot (with
PXE off if the system has PXE).
• enablednonepxe: Enables the first NIC during system boot
(with PXE off if the system has
PXE).
• enabledwithiscsi: Enables the first NIC during system boot
(with iSCSI on if the system has iSCSI).
setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi
• enabled: Enables the second
NIC during system boot.
• enabledwithpxe: Enables the second NIC during system boot (with PXE on if the system has PXE).
• disabled: Disables the second
NIC during system boot.
68
name=value pair 1 attribute= attribute=nic3 attribute=nic4 name=value pair 2 setting= Description
• enabledonly: Enables the second NIC during system boot (with PXE off if the system has PXE).
• enablednonepxe: Enables the second NIC during system boot (with PXE off if the system has PXE).
• enabledwithiscsi: Enables the second NIC during system boot (with iSCSI on if the system has iSCSI).
setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi
• enabled: Enables the third
NIC during system boot.
• enabledwithpxe: Enables the third NIC during system boot
(with PXE on if the system has
PXE).
• disabled: Disables the third
NIC during system boot.
• enabledonly: Enables the third NIC during system boot
(with PXE off if the system has
PXE).
• enablednonepxe: Enables the third NIC during system boot
(with PXE off if the system has
PXE).
• enabledwithiscsi: Enables the third NIC during system boot
(with iSCSI on if the system has iSCSI).
setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi
• enabled: Enables the fourth
NIC during system boot.
• enabledwithpxe: Enables the fourth NIC during system boot (with PXE on if the system has PXE).
• disabled: Disables the fourth
NIC during system boot.
• enabledonly: Enables the fourth NIC during system boot (with PXE off if the system has PXE).
• enablednonepxe: Enables the fourth NIC during system boot (with PXE off if the system has PXE).
• enabledwithiscsi: Enables the fourth NIC during system boot (with iSCSI on if the system has iSCSI).
69
name=value pair 1 attribute= attribute=numlock name=value pair 2 setting= setting=on | off attribute=NodeInterleave
NOTE: Use
NodeInterleave instead of numa as numa will be deprecated in future releases.
setting=enabled | disabled attribute=ppaddress attribute=ppmode attribute=primaryscsi attribute=romb
Description
• on: Uses the keypad as number keys.
• off: Uses the keypad as arrow keys.
• enabled: Enables Node
Interleaving and disables Non-
Uniform Memory Access.
• disabled: Disables Node
Interleaving and enables Non-
Uniform Memory Access.
setting=off | lpt1 | lpt2 | lpt3 setting=at | ps2 | ecp | epp
• off: Disables the parallel port address.
• lpt1: Locates the device on
LPT1.
• lpt2: Locates the device on
LPT2.
• lpt3: Locates the device on
LPT3.
• at: Sets the parallel port mode to AT.
• ps2: Sets the parallel port mode to PS/2.
• ecp: Sets the parallel port mode to ECP (extended capabilities port).
• epp: Sets the parallel port mode to EPP (enhanced parallel port).
setting=on | off force=true
CAUTION: If you modify the setting for primary scsi, romb, romba, or rombb, the system becomes inoperable until you reinstall the operating system.
• on: Enables this device.
• off: Disables this device.
• force=true: Verification of setting change.
setting=raid | off | scsi force=true • raid: Instructs the BIOS to detect RAID-on-motherboard as a RAID device.
• off: Disables RAID-onmotherboard during system boot.
• scsi: Instructs the BIOS to detect the RAID-on-
70
name=value pair 1 attribute= attribute=romba attribute=rombb attribute=sata name=value pair 2 setting= setting=raid | scsi force=true setting=raid | scsi force=true setting=off | ata | raid
Description motherboard device as a SCSI device.
• force=true: Verification of setting change.
• raid: Instructs the BIOS to detect RAID-on-motherboard channel A as a RAID device.
• scsi: Instructs the BIOS to detect the RAID-onmotherboard device as a SCSI device.
• force=true: Verification of setting change.
• raid: Instructs the BIOS to detect RAID-on-motherboard channel B as a RAID device.
• scsi: Instructs the BIOS to detect the RAID-onmotherboard device as a SCSI device.
• force=true: Verification of setting change.
• off: Disables the SATA controller.
• ata: Sets the onboard SATA controller to ATA mode.
• raid: Sets the onboard SATA controller to RAID mode.
attribute=sataport (0...7) or (a...h) setting=off | auto attribute=secondaryscsi attribute=serialportaddr attribute=serialcom setting=on | off
• off: Disables the SATA port.
• auto: Automatically enables the SATA port.
• on: Enables secondary SCSI.
• off: Disables this device.
setting=default | alternate | com1
| com2
• default: Maps to Serial device1=COM1, Serial device2=COM2.
• alternate: Maps to Serial device1=COM2, Serial device2=COM1
• com1: Sets serial port address to COM1.
• com2: Sets serial port address to COM2.
setting=off | on | com1 | com2 | onwithconsole
• off: Disables serial communication setting.
71
name=value pair 1 attribute= attribute=serialport1 attribute=serialport2 attribute=speaker name=value pair 2 setting= Description
• on: Enables serial communication setting without console redirection.
• com1: Enables serial communication setting with console redirection through
COM1.
• com2: Enables serial communication setting with console redirection through
COM2.
• onwithconsole: Enables serial communication with console redirection through COM1 and COM2.
NOTE: The setting onwithconsole is supported only on Dell blade systems.
setting=off | auto | com1 | com3 | bmcserial | bmcnic | rac | com1bmc
• off: Disables serial port 1.
• auto: Maps serial port 1 to a
COM port.
• com1: Maps serial port 1 to
COM port 1.
• com3: Maps serial port 1 to
COM port 3.
• bmcserial: Maps serial port 1 to BMC Serial.
• bmcnic: Maps serial port 1 to the Baseboard Management
Controller (BMC) NIC.
• rac: Maps serial port 1 to the
Remote Access Controller
(RAC.)
• com1bmc: Maps serial port 1 to COM port 1 bmc.
NOTE: This command is applicable only on selected
x8xx systems.
setting=off | auto | com2 | com4 • off: Disables serial port 2.
• auto: Maps serial port 2 to a
COM port.
• com2: Maps serial port 2 to
COM port 2.
• com4: Maps serial port 2 to
COM port 4.
setting=on | off • on: Enables the speaker.
• off: Disables the speaker.
72
name=value pair 1 attribute= attribute=cputurbomode attribute=uausb attribute=usb attribute=usbb attribute=cstates name=value pair 2 setting= setting=enabled | disabled setting=on | backonly | off setting=enabled | disabled setting=enabled | enabledwithbios | disabled setting=enabled | disabled
Description
CPU turbo mode can increase the CPU frequency when the system is operating below the thermal, power, or current limits.
• enabled: Enables CPU Turbo
Mode.
• disabled: Disables CPU Turbo
Mode.
• on: Enables the useraccessible USB port(s).
• backonly: Enables only the user-accessible USB port(s) located at the back of the system.
• off: Disables the useraccessible USB port(s).
• enabled: Enables the USB port(s).
• disabled: Disables the USB port(s).
NOTE: Depending on the system's hardware you can configure either usb or usbb.
• enabled: Enables the USB port(s) during system boot, without BIOS support.
• enabledwithbios: Enables the
USB port(s) during system boot, with BIOS support.
• disabled: Disables the USB port(s) during system boot.
NOTE: Depending on the system's hardware you can configure either usb or usbb.
• enabled: Enables the processor to go into a deep sleep state when the system is not utilized.
• disabled: Disables the processor from going into a deep sleep state when the system is not utilized.
BIOS setup settings
The following table lists the BIOS setup attributes supported on Dell’s 12 th generation and later
PowerEdge systems. The attributes are grouped based on the hardware configuration. The possible attributes may vary in a specific group. The omconfig chassis biossetup command does not display the read-only attributes.
73
NOTE: If you have configured the setup password, then, always set the same password when you configure any BIOS settings.
Table 22. BIOS Setup Settings on PowerEdge12G and later systems
Group
BIOS Option
Settings name=value pair 1 attribute= attribute=BootSeq name=value pair 2 setting= sequence=aliasname1, aliasname2,..... aliasnameN
Boot Settings attribute=HddSeq attribute=BootMode attribute=BootSeqRetry attribute=HddFailover
NOTE: The option is supported only on 13G and later systems.
sequence=aliasname1, aliasname2,..... aliasnameN setting=Bios | Uefi setting=Enabled | Disabled setting=Enabled | Disabled
Integrated
Devices attribute=SetBootOrderFqdd1–
SetBootOrderFqdd16
NOTE: The option is supported only on 13G and later systems.
setting=<string> attribute=SetLegacyHddOrder
Fqdd1–
SetLegacyHddOrderFqdd16
NOTE: The option is supported only on 13G and later systems.
setting=<string> attribute=EmbVideo setting=Enabled | Disabled attribute=IntegratedNetwork1 attribute=IntegratedNetwork2 attribute=IntegratedRaid attribute=IntegratedSas attribute=InternalSdCard attribute=InternalSdCardRedun dancy attribute=InternalUsb attribute=IoatEngine attribute=OsWatchdogTimer attribute=SriovGlobalEnable setting=Enabled | DisabledOs setting=Enabled | DisabledOs setting=Enabled | Disabled setting=Enabled | Disabled setting=On | Off setting=Mirror | Disabled setting=On | Off setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled
74
Group name=value pair 1 attribute= attribute=UsbPorts name=value pair 2 setting= setting=AllOn | OnlyBackPortsOn | AllOff attribute=Usb3Setting
NOTE: The option is supported only on 13G and later systems.
setting=Auto | Enabled | Disabled attribute=InternalSdCardPrimary
Card setting=SdCard1 | SdCard2
NOTE: The option is supported only on 13G and later systems.
attribute=CurrentEmbVideoStat e
NOTE: The option is supported only on 13G and later systems.
setting=Enabled | Disabled
Memory Settings attribute=MemOpMode attribute=MemTest attribute=NodeInterleave attribute=SysMemSize attribute=SysMemSpeed attribute=SysMemType attribute=SysMemVolt attribute=VideoMem attribute=ClusterOnDie
NOTE: The option is supported only on 13G and later systems.
setting=OptimizerMode | SpareMode | MirrorMode
| AdvEccMode | SpareWithAdvEccMode setting=Enabled | Disabled setting=Enabled | Disabled setting=<string> setting=<string> setting=<string> setting=<string> setting=<string> setting=Enabled | Disabled
Miscellaneous
Settings attribute=AssetTag setting=<string> attribute=NumLock attribute=ErrPrompt attribute=SysMgmtNVByte1 attribute=SysMgmtNVByte1 attribute=CorrEccSmi setting=On | Off setting=Enabled | Disabled setting=<string> setting=<string> setting=Enabled | Disabled
75
Group name=value pair 1 attribute= attribute=InSystemCharacterizat ion name=value pair 2 setting= setting=FastBoot | OptimizedBoot | Disabled
NOTE: The option is supported only on 13G and later systems.
attribute=ReportKbdErr attribute=SystemUefiShell setting=Report | NoReport setting=Enabled | Disabled attribute=ForceInt10
NOTE: The option is supported only on 13G and later systems.
setting=Enabled | Disabled
Network Settings
NOTE: The option is supported only on 13G and later systems.
attribute=PxeDev1EnDis -
PxeDev4EnDis setting=Enabled | Disabled attribute=PxeDev1Interface -
PxeDev4Interface attribute=PxeDev1Protocol -
PxeDev4Protocol attribute=PxeDev1VlanEnDis -
PxeDev4VlanEnDis attribute=PxeDev1VlanId -
PxeDev4VlanId
One-Time Boot
NOTE: The option is not supported on Dell
PowerEdge
13G and later systems.
attribute=PxeDev1VlanPriority -
PxeDev4VlanPriority attribute=OneTimeBootMode setting=Enabled | Disabled setting=IPv4 | IPv6 setting=Enabled | Disabled setting=<integer> setting=<integer> setting=Disabled | OneTimeBootSeq |
OneTimeHddSeq | OneTimeUefiBootSeq |
OneTimeCustomBootSeqStr |
OneTimeCustomHddSeqStr |
OneTimeCustomUefiBootSeqStr attribute=OneTimeBootSeqDev sequence=aliasname1, aliasname2,..... aliasnameN attribute=OneTimeHddSeqDev sequence=aliasname1, aliasname2,..... aliasnameN
76
Group
Processor
Settings name=value pair 1 attribute= attribute=OneTimeUefiBootSeq
Dev attribute=ControlledTurbo name=value pair 2 setting= sequence=aliasname1, aliasname2,..... aliasnameN setting=Enabled | Disabled | Custom attribute=DataReuse attribute=DcuIpPrefetcher attribute=DcuStreamerPrefetch er attribute=LogicalProc attribute=Proc1Brand attribute=Proc1Id attribute=Proc1L2Cache attribute=Proc1L3Cache attribute=Proc1NumCores attribute=Proc2Brand attribute=Proc2Id attribute=Proc2L2Cache attribute=Proc2L3Cache attribute=Proc2NumCores attribute=Proc64bit attribute=ProcAdjCacheLine attribute=ProcBusSpeed attribute=ProcCores setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled setting=<string> setting=<string> setting=<string> setting=<string> setting=<integer> setting=<string> setting=<string> setting=<string> setting=<string> setting=<integer> setting=<string> setting=Enabled | Disabled setting=<string> setting=Single | All | Dual | Quad | 1 | 2 | 4 | 6 | 8 |
10 | 12 | 14 | 16 attribute=ProcCoreSpeed attribute=ProcExecuteDisable attribute=ProcHwPrefetcher attribute=ProcVirtualization setting=<string> setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled attribute=QpiBandwidthPriority setting=InputOutput | Compute attribute=QpiSpeed setting=MaxDataRate | 8GTps | 7GTps | 6GTps attribute=RtidSetting setting=Enabled | Disabled attribute=Proc1ControlledTurbo
– Proc4ControlledTurbo setting=Disabled | ControlledTurboLimit |
ControlledTurboLimitMinus1 |
ControlledTurboLimitMinus2 |
ControlledTurboLimitMinus3
77
Group
SATA Settings
Serial
Communication name=value pair 1 attribute=
NOTE: The option is supported only on 13G and later systems.
name=value pair 2 setting= attribute=ProcConfigTdp
NOTE: The option is supported only on 13G and later systems.
setting=Nominal | Level1 | Level2 attribute=ProcATS setting=Enabled | Disabled
NOTE: The option is read-only if
ProcVirtualization is set to Disabled.
attribute=ProcX2Apic
NOTE: The option is supported only on 13G and later systems.
setting=Enabled | Disabled
NOTE: The option is read-only if
ProcVirtualization is set to Disabled.
attribute=EmbSata attribute=eSataPort1 setting=Off | AtaMode | RaidMode | AhciMode setting=Off | Auto attribute=eSataPort1Capacity setting=<string> attribute=eSataPort1DriveType setting=<string> attribute=eSataPort1Model setting=<string> attribute=SataPortA - SataPortJ setting=Off | Auto setting=<string> attribute=SataPortACapacity -
SataPortJCapacity attribute=SataPortADriveType -
SataPortJDriveType setting=<string> setting=<string> attribute=SataPortAModel -
SataPortJModel attribute=SecurityFreezeLock attribute=WriteCache attribute=ConTermType setting=Enabled | Disabled setting=Enabled | Disabled setting=Vt100Vt220 | Ansi attribute=ExtSerialConnector attribute=FailSafeBaud attribute=RedirAfterBoot attribute=SerialComm setting=Serial1 | Serial2 | RemoteAccDevice setting=115200 | 57600 | 19200 | 9600 setting=Enabled | Disabled setting=OnNoConRedir | OnConRedirCom1 |
OnConRedirCom2 | Off
78
Group name=value pair 1 attribute= attribute=SerialPortAddress
Slot Disablement attribute=Slotn
System
Information attribute=SysMfrContactInfo name=value pair 2 setting= setting=Serial1Com1Serial2Com2 |
Serial1Com2Serial2Com1 | Com1 | Com2 setting=Enabled | Disabled | BootDriverDisabled setting=<string> attribute=SystemBiosVersion setting=<string> attribute=SystemManufacturer setting=<string> attribute=SystemModelName attribute=SystemServiceTag setting=<string> setting=<string> attribute=SystemMeVersion
NOTE: The option is supported only on 13G and later systems.
setting=<string> attribute=UefiComplianceVersio n setting=<string>
NOTE: The option is supported only on 13G and later systems.
System Profile
Settings attribute=SystemCpldVersion attribute=MemFrequency attribute=MemPatrolScrub attribute=MemRefreshRate attribute=MemVolt setting=<string> setting=MaxPerf |1866MHz | 1600MHz | 1333MHz
|1067MHz | 800MHz | MaxReliability setting=Standard | Extended | Disabled setting=1x | 2x setting=AutoVolt | Volt15V | Volt135V
NOTE: Volt15V represents 1.5 Volt and
Volt135V represents 1.35 Volt attribute=ProcC1E attribute=ProcCStates attribute=ProcPwrPerf attribute=ProcTurboMode setting=Enabled | Disabled setting=Enabled | Disabled setting=MaxPerf | MinPwr | SysDbpm | OsDbpm setting=Enabled | Disabled attribute=SysProfile setting=PerfPerWattOptimizedOs |
PerfPerWattOptimizedDapc | PerfOptimized |
Custom | DenseCfgOptimized attribute=EnergyEfficientTurbo setting=Enabled | Disabled
79
Group name=value pair 1 attribute=
NOTE: The option is supported only on 13G and later systems.
name=value pair 2 setting= attribute=EnergyPerformanceBi as
NOTE: The option is supported only on 13G and later systems.
setting=MaxPower | BalancedPerformance |
BalancedEfficiency | LowPower attribute=UncoreFrequency
NOTE: The option is supported only on 13G and later systems.
setting=DynamicUFS | MaxUFS | MinUFS attribute=ProcNTurboCoreNum
(N= 0-3) , where the value of N is 0–3.
setting=All | 1 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18
NOTE: The option is supported only on 13G and later systems.
attribute=MonitorMwait attribute=CollaborativeCpuPerf
Ctrl setting=Enabled | Disabled setting=Enabled | Disabled
System Security attribute=AcPwrRcvry attribute=AcPwrRcvryDelay setting=On | Off | Last setting=Immediate | User | Random attribute=AcPwrRcvryUserDelay setting=<integer> attribute=AesNi setting=Enabled | Disabled attribute=IntelTxt attribute=NmiButton attribute=PasswordStatus attribute=PwrButton attribute=SetupPassword attribute=SysPassword attribute=TpmActivation
NOTE: The option is not supported on Dell
PowerEdge 13G and later systems.
setting=On | Off setting=Enabled | Disabled setting=Locked | Unlocked setting=Enabled | Disabled setting=<string> setting=<string> setting=NoChange | Activate | Deactivate
80
Group name=value pair 1 attribute= attribute=TpmClear
NOTE: The option is not supported on Dell
PowerEdge 13G and later systems.
name=value pair 2 setting=
CAUTION: Clearing the TPM will cause loss of all keys in the TPM. This could affect booting of the operating system.
setting=Yes | No attribute=TpmSecurity attribute=TpmInfo
NOTE: The option is supported only on 13G and later systems.
setting=Off | OnPbm | OnNoPbm setting=<string> attribute=TpmCommand
NOTE: The option is supported only on 13G and later systems.
setting=None | Activate | Deactivate | Clear attribute=TpmStatus attribute=TcmActivation
NOTE: The option is not supported on Dell
PowerEdge 13G and later systems.
setting=<string> setting=NoChange | Activate | Deactivate attribute=TcmClear
NOTE: The option is not supported on Dell
PowerEdge 13G and later systems.
attribute=TcmSecurity
NOTE: The option is not supported on Dell
PowerEdge 13G and later systems.
CAUTION: Clearing the TCM will cause loss of all keys in the TCM. This could affect booting of the operating system.
setting=Yes | No setting=Off | OnPbm | OnNoPbm attribute=SecureBoot
NOTE: The option is supported only on 13G and later systems.
setting=Enabled | Disabled attribute=SecureBootPolicy
NOTE: The option is supported only on 13G and later systems.
setting=Enabled | Disabled
81
Group name=value pair 1 attribute= attribute=UefiVariableAccess attribute=UefiBootSeq name=value pair 2 setting= setting=Standard | Controlled sequence=aliasname1, aliasname2,..... aliasnameN UEFI Boot
Settings
Omconfig Chassis Currents Or Omconfig Mainsystem Currents
NOTE: This command is no longer available through Server Administrator.
Omconfig Chassis Fans Or Omconfig Mainsystem Fans
Use the omconfig chassis fans or omconfig mainsystem fans command to set fan probe warning thresholds. As with other components, you can view both warning and failure threshold values, but you cannot set failure thresholds. The system manufacturer sets the minimum and maximum failure thresholds.
Valid Parameters For Fan Warning Thresholds
The following table shows the valid parameters for setting fan warning thresholds:
Table 23. omconfig chassis fans or omconfig chassis fans name=value pair index= <n> warnthresh=default minwarnthresh=<n> maxwarnthresh=<n>
Description
Number of the probe or probe index (must specify).
Sets minimum and maximum warning thresholds to default.
Minimum warning threshold.
Maximum warning threshold.
Default minimum and maximum warning thresholds
NOTE: Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to set warning threshold values to default values.
To set both the upper and lower fan warning threshold values to the recommended default value, type: omconfig chassis fans index=0 warnthresh=default or omconfig mainsystem fans index=0 warnthresh=default
You cannot default one value and set another. In other words, if you default the minimum warning threshold value, you are also selecting the default value for the maximum warning threshold value.
Specifying a value for minimum and maximum warning thresholds
If you prefer to specify values for the fan probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values. In the following
82
example, the probe that is being configured is probe 0. The first command sets only the minimum threshold; the second sets the minimum and maximum thresholds: omconfig chassis fans index=0 minwarnthresh=4580 or omconfig mainsystem fans index=0 minwarnthresh=4580 omconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160 or omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the following message is displayed:
Fan probe warning threshold(s) set successfully.
Omconfig chassis frontpanel or omconfig mainsystem frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to:
• configure the power button and the Nonmasking Interrupt (NMI) button
• configure the LCD to display:
– No information
– Custom information
– Default system information
– Service tag, system name
– Remote access MAC addresses
– System power
– Remote access IP address
– Ambient temperature of the system
– Remote access IPv4 address
– Remote access IPv6 address
• Specify and configure the LCD line number
• View the encryption state report of the LCD
• Configure LCD to indicate an active remote session when the Kernel-based Virtual Machine (KVM) is available
NOTE: You can configure the Power and NMI buttons only if they are present on the system.
The following table displays the valid parameters for the command:
Table 24. Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel name=value pair 1 Description lcdindex=<index> config=none | default | custom name=value pair 2
NA
NA
Specifies the LCD line number.
• none: Sets the LCD text to none.
• default: Sets the LCD text to default.
• custom: Sets the LCD text to custom.
83
name=value pair 1 text=<custom text> nmibutton=enable | disable powerbutton=enable | disable
NA config=sysname config=syspower config=servicetag config=remoteaccessip v4 config=remoteaccessip v6 config=remoteaccessm ac
NA
NA config=ipv4idrac config=ipv6idrac config=macidrac config=ambienttemp security=modify security=view security=disabled NA remoteindication=true NA
NA
NA
NA
NA
NA
NA
NA
NA name=value pair 2
NA
NA
Description
Sets the custom text for LCD when config=custom.
• enable: Enables the NMI button on the system.
• disable: Disables the NMI button on the system.
• true: Enables the Power button on the system.
• false: Disables the Power button on the system.
Sets the name of the system.
Sets the system power information.
Sets the system service tag information.
Sets the remote access IPv4 information.
Sets the remote access IPv6 information.
Sets the remote access MAC address.
Sets IPv4 DRAC information.
Sets IPv6 DRAC information.
Sets the DRAC’s MAC address.
Sets the system temperature in centigrade.
Allows you to modify the LCD text.
Provides read-only access to the LCD text.
Provides limited access to the LCD text.
LCD flashes when the system detects an active remote session.
NOTE: The options ipv4idrac, ipv6idrac, and macidrac are deprecated.
Omconfig Chassis Info Or Omconfig Mainsystem Info
Use the omconfig chassis info or omconfig mainsystem info command to enter an asset tag name and a chassis name for the system. For a blade systems, enter asset tag names for modular components as well.
The following table displays the valid parameters for the command:
Table 25. Valid Parameters Of Omconfig Chassis Info Or Omconfig Mainsystem Info name=value pair index=<n> tag=<text>
Description
Number of the chassis whose asset tag or name you are setting.
Asset tag in the form of alphanumeric text. Letters or numbers should not exceed
10 characters.
84
name=value pair name=<text>
Description
NOTE: The parameter is not supported on 13G and later systems. For setting the asset tag, use omconfig chassis biossetup attribute=assetag seting=<value>.
Name of the chassis.
In the following example, the asset tag for the main system chassis is being set to buildsys: omconfig chassis info index=0 tag=buildsys or omconfig mainsystem info index=0 tag=buildsys
Index 0 always defaults to the main system chassis. The following command omits index=n, but accomplishes the same: omconfig chassis info tag=buildsys or omconfig mainsystem info tag=buildsys
An acceptable command, when executed, results in the following message:
Chassis info set successfully.
For some chassis, you can assign a different name. You cannot rename the main system chassis. In the following example, the command renames chassis 2 from storscsi1 to storscsia: omconfig chassis info index=2 name=storscsia or omconfig mainsystem info index=2 name=storscsia
As with other commands, the CLI issues an error message if you do not have a chassis 2 (the main chassis=0). The CLI allows you to issue commands only for the system configuration you have.
Omconfig Chassis Leds Or Omconfig Mainsystem Leds
Use the omconfig chassis leds or omconfig mainsystem leds command to specify when to flash a chassis fault LED or chassis identification LED. This command also allows you to clear the LED of the system hard drive. The following table displays the valid parameters for the command.
Table 26. Valid Parameters Of Omconfig Chassis Leds Or Omconfig Mainsystem Leds name=value pair 1 name=value pair 2 index=<n> NA led=fault led=hdfault severity=warning | critical action=clear
Description
Number of the chassis where the LED resides
(defaults to chassis 0, main system chassis).
Select to flash the LED either when a warning event occurs or when a critical event occurs.
Sets the number of faults for the hard drive back to zero (0).
85
name=value pair 1 name=value pair 2 led=identify flash=off | on time-out=<n>
Description
Sets the chassis identification LED to off or on.
Set the time-out value for the LED to flash to a number of seconds.
Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode
Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify the redundancy mode to use for the system memory in case of memory errors.
Redundant memory enables a system to switch to other available memory modules if unacceptable errors are detected in the modules that the system is currently using. The omconfig chassis memorymode or omconfig mainsystem memorymode command allows you to disable redundancy; when you disable redundancy, you instruct the system not to switch to other available memory modules when the memory module the system is using begins to encounter errors. To enable redundancy, choose among spare, mirror, raid, and DDDC.
Spare mode disables a bank of system memory in which a correctable memory event is detected, enables the spare bank, and copies all the data from the original bank to the spare bank. Spare bank requires at least three banks of identical memory; the operating system does not recognize the spare bank.
Mirror mode switches to a redundant copy of memory when an uncorrectable memory event is detected.
After switching to the mirrored memory, the system does not switch back to the original system memory until the next reboot. The operating system does not recognize half of the installed system memory in this mode.
RAID mode provides an extra level of memory checking and error recovery at the expense of some memory capacity.
The DDDC mode enables double device data correction. This ensures data availability after hard failure of x4 DRAM.
NOTE: This command is applicable only on systems prior to PowerEdge 12G systems. On
PowerEdge 12G systems, memorymode is grouped under Memory Settings of the BIOS setup
group. For more information, see BIOS Setup Groups on PowerEdge 12G Systems .
To configure the attribute on systems prior to PowerEdge 12G, see the following table. The table displays the valid parameters for the command.
Table 27. Valid Parameters Of Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode name=value pair 1 index=<n>
Description
Number of the chassis where the memory module resides (the default is chassis 0, the main system chassis).
redundancy=spare | mirror | disabled | raid5 | dddc spare: Disables the memory module that has a correctable memory event and copies the failing module’s data to a spare bank.
mirror: Switches the systems to a mirrored copy of the memory if the failing module has an
86
name=value pair 1 opmode=mirror | optimizer | advecc
Description uncorrectable memory event. In the mirror mode, the operating system does not switch back to the original module until the system reboot.
disabled: Indicates that the system is not to use other available memory modules if uncorrectable memory events are detected.
raid5: Method of system memory configuration.
This is logically similar to the RAID-5 mode used in hard drive storage systems. This memory mode provides an extra level of memory checking and error recovery at the expense of some memory capacity. The RAID mode supported is RAID level 5 striping with rotational parity.
dddc: The dddc mode enables double device data correction. This ensures data availability after hard failure of x4 DRAM.
mirror: Switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event. In the mirror mode, the operating system does not switch back to the original module until the system reboots.
optimizer: Enables the DRAM controllers to operate independently in 64-bit mode and provide optimized memory performance.
advanced ECC (advecc): Enables the two DRAM controllers to combine in 128-bit mode and provide optimized reliability. Memory that are not teamed by the controllers is not reported to the operating system.
Omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement
Use the omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement command to configure power cap and manage profiles that control power utilization.
NOTE: This command is valid only on systems prior to PowerEdge 12G systems.
The following table displays the valid parameters for the command:
Table 28. Valid Parameters Of Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem
Pwrmanagement name=value pair 1 config=budget name=value pair 2 cap=<value>
Description
Sets the threshold value for power budget.
87
name=value pair 1 name=value pair 2 setting=enable | disable
Description
NOTE: From PowerEdge
12G system onwards, power budget requires license to configure power cap. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License
Manager at dell.com/ support/manuals.
NOTE: Power budget requires license to configure power cap. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License
Manager at dell.com/ support/manuals.
enable: Enables powercap settings.
disable: Disables powercap settings.
unit=watt | btuphr | percent config=profile
NOTE: This option is supported on systems prior to PowerEdge 12G systems.
profile=maxperformance | apc | osctrl | custom watt: Configure the unit in Watts.
btuphr: Configure the unit in
BTU/hr.
percent: Configure the unit in percentage.
maxperformance: Sets the processor to the highest supported processor state. It offers maximum performance mode with minimal power economy.
apc: Active Power Control (apc) enables the demand-based power management controlled by BIOS.
osctrl: OS Control (osctrl) enables the demand-based power management controlled by the operating system.
custom: This profile allows you to configure individual BIOS
88
name=value pair 1 name=value pair 2 fanmode=min | max
Description settings. It offers added control by displaying the underlying BIOS settings.
cpupowermode=min | max | systemdbpm | osdbpm min: Sets the CPU power consumption to minimum.
max: Sets the CPU power consumption to maximum.
systemdbpm: Sets the mode to system demand based power management.
osdbpm: Sets the mode to operating system demand based power management.
NOTE: These options are applicable only when a custom profile is selected.
memorypowermode=min | 800 |
1067 | 1333 | max min: Sets the mode to minimum power utilization.
800 | 1067 | 1333: Set the mode to 800, 1067, or 1333 MHz.
max: Sets the mode to maximum performance.
NOTE: These options are applicable only when a custom profile is selected.
min: Sets the fanmode to minimum power utilization.
max: Sets the fanmode to maximum power utilization.
NOTE: These options are applicable only when a custom profile is selected.
NOTE: Reboot the system for the power profiles setup options to take effect.
Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring
Use the omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring command to configure power consumption information.
The following table displays the valid parameters for the command:
89
Table 29. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring name=value pair 1 index=<n> config=probe name=value pair 2
NA warnthresh=settodefault warnthresh=<n > unit=watt | btuphr
Description
Number of the probe or probe index (must specify).
Sets the minimum and maximum warning thresholds values to default.
Sets a value for the warning threshold.
watt: Displays the unit in Watts.
btuphr: Displays the unit in
BTU/hr.
config=resetreading type=energy | peakpower energy: Resets the system energy reading.
peakpower: Resets the system peak power.
NOTE: This command is applicable only on selected Dell 10G systems that support PMBus.
NOTE: Power monitoring requires license to configure the power budget information. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License Manager at dell.com/openmanagemanuals.
Default warning thresholds
NOTE: Sensor managing capabilities vary across systems.
To set both the upper and lower power consumption probe warning threshold values to the recommended default value, type: omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefault or omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum warning threshold value, you are also selecting the default value for the maximum warning threshold value.
Specify A Value For Warning Thresholds
If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the probe you are configuring and the warning threshold value. Configure the values to display either in BTU/hr or Watts. In the following example, the probe that is being configured is probe 4: omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt or omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325 unit=btuphr
90
When you issue the command and the system sets the values you specify, the following message is displayed:
Power consumption probe warning threshold(s) set successfully.
Omconfig chassis remoteaccess or omconfig mainsystem remoteaccess
Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to configure:
• Remote access on a local area network (LAN).
• The serial port for BMC or RAC, whichever is installed.
• The BMC or RAC on a serial over LAN connection.
• Terminal settings for the serial port.
• Advanced settings for a serial over LAN connection.
• Information on a BMC or RAC user.
• Information on IPv6 and IPv4 interfaces.
NOTE: Enter the user ID to configure user information.
Type: omconfig chassis remoteaccess or omconfig mainsystem remoteaccess
The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the available configurations. The following table displays the valid parameters:
Table 30. Valid Parameters Of Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess name=value pair 2 Description name=value pair 1 config= config=additional ipv4=enable | disable enable: IPv4 stack to load on iDRAC.
disable: IPv4 stack to flush on iDRAC.
config=advsol ipv6=enable | disable characcuminterval=number charsendthreshold=number enable: Enables IPv6 stack to load on iDRAC.
disable: Disables IPv6 stack to unload on iDRAC.
NOTE: This option requires license to enable or disable ipv6. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License
Manager at dell.com/ openmanagemanuals.
number: Sets the character accumulate interval in 5 millisecond intervals.
number: Sets the number of characters. BMC automatically sends a serial over LAN data
91
name=value pair 1 config= name=value pair 2 Description enableipmi= true | false primarynw=dedicated | lom1 | lom2 | lom3 | lom4 packet that contains the number of characters as soon as this number of characters (or greater) has been accepted from the baseboard serial controller into the BMC.
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false true: Enables DRAC NIC.
false: Disables DRAC NIC nicselection=sharedwithfailover onall | nic1 |teamednic1nic2 | dracnic sharedwithfailoveronall: Configures the new
NIC selection option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming functionality.
dracnic: Enables DRAC NIC if DRAC 5 is installed.
NOTE: The nicselection option is supported only on PowerEdge 10G and
11G systems. From PowerEdge 12G systems onwards, primarynw and failovernw replaces nicselection.
dedicated: Configures dedicated port as primary network for remote access.
NOTE: This option requires license to configure primarynw as dedicated. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell
License Manager at dell.com/ openmanagemanuals.
lom 1: Configures lom1 port as the primary network for remote access.
lom 2: Configures lom2 port as the primary network for remote access.
lom 3: Configures lom3 port as the primary network for remote access.
lom 4: Configures lom4 port as the primary network for remote access.
92
name=value pair 1 config= name=value pair 2 Description
NOTE: The primarynw option is supported from PowerEdge12G systems onward. If the primarynw is set to dedicated, then set failovernw to none.
NOTE: If the primarynw is set to dedicated, then set failovernw to none.
failovernw=none | lom1 | lom2 | lom3 | lom4 | all none: Configures the failover network to none.
lom 1: Configures the failover network to lom
1.
lom 2: Configures the failover network to lom
2.
lom 3: Configures the failover network to lom
3.
lom 4: Configures the failover network to lom
4.
all: Configures the failover network to all loms.
NOTE: The failovernw option is supported on PowerEdge12G systems onward.
Configure both primarynw and failovernw to set the nicselection. The primarynw and failovernw options cannot have the same value.
NOTE: Configure both primarynw and failovernw to set the nicselection. The primarynw and failovernw options cannot have the same value.
NOTE: Failovernw requires license to configure the ports. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License
Manager at dell.com/ openmanagemanuals.
ipaddress=IP Sets the IP address if you have selected static as the IP address source for the BMC LAN interface.
subnet=Subnet gateway=Gateway
Sets a subnet mask if you have selected static as the IP address source for the BMC LAN interface.
Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface.
93
name=value pair 1 config= name=value pair 2 ipsource=static | dhcp | systemsoftware ipaddressv6=<IPv6 address> prefixlength= length gatewayv6=<value> ipsourcev6=static | auto altdnsserverv6 dnssourcev6=static | auto vlanenable=true | false vlanid=number vlanpriority=number privilegelevel=administrator | operator | user encryptkey=text confirmencryptkey=text
Description static: Static if the IP address of the BMC LAN interface is a fixed, assigned IP address.
dhcp: DHCP if the source of the IP address of the BMC LAN interface is the dynamic host configuration protocol.
systemsoftware: System software if the source of the IP address of the BMC LAN interface is from the system software.
NOTE: All commands may not be supported on the system.
Validates the IPv6 address for configuration.
Validates the IPv6 gateway.
static: IPv6 address source is set to static.
auto: IPv6 address source is set to auto.
Validates the address of the alternate DNS server for configuration.
static: DNS source is set to static.
auto: DNS source is set to auto.
true: Enables the virtual LAN identification.
false: Disables the virtual LAN identification.
number: Virtual LAN identification in the range of 1 to 4094.
number: Priority of virtual LAN identification in the range of 0 to 7.
administrator: Sets the maximum privilege level that is accepted on a LAN channel, to
Administrator.
operator: Sets the maximum privilege level that is accepted on a LAN channel, to
Operator.
user: Sets the maximum privilege level that is accepted on a LAN channel, to User.
text: Text used for encryption and confirmation of encryption.
94
name=value pair 1 config= name=value pair 2 config=serial
Description prefdnsserverv6=<value> Validates the preferred DNS server for configuration.
baudrate=9600 | 19200 | 38400
| 57600 | 115200
9600: Sets the connection speed to 9600 bits per second.
19200: Sets the connection speed to 19200 bits per second.
38400: Sets the volatile and non-volatile connection speed to 38400 bits per second.
57600: Sets the volatile and non-volatile connection speed to 57600 bits per second.
115200: Sets the volatile and non-volatile connection speed to 115200 bits per second.
flowcontrol=none | rtscts none: No control over the flow of communication through the serial port.
rtscts: RTS is ready to send and CTS is clear to send.
mode=directbasic | directterminal | directbasicterminal | modembasic | modemterminal | modembasicterminal directbasic: Type of messaging used for IPMI messaging over a serial connection.
directterminal: Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a serial connection.
directbasicterminal: Both basic and terminal mode messaging over a serial connection.
modembasic: Type of messaging used for IPMI messaging over a modem.
modemterminal: Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a modem.
modembasicterminal: Both basic and terminal messaging over a modem.
NOTE: All commands may not be supported on the system.
privilegelevel=administrator | operator | user administrator: Sets the maximum privilege level that are accepted on a serial connection, to Administrator.
operator: Sets the maximum privilege level that are accepted on a serial connection, to
Operator.
95
name=value pair 1 config= name=value pair 2 Description config=serialoverlan enable=true | false user: Sets the maximum privilege level that are accepted on a serial connection, to User.
true: Enables serial over LAN for the BMC.
false: Disables serial over LAN for the BMC.
baudrate=9600 | 19200 | 38400
| 57600 | 115200
9600: Sets the volatile and nonvolatile connection speed to 9600 bits per second.
19200: Sets the volatile and non-volatile connection speed to 19200 bits per second.
38400: Sets the volatile and non-volatile connection speed to 38400 bits per second.
57600: Sets the volatile and non-volatile connection speed to 57600 bits per second.
115200: Sets the volatile and non-volatile connection speed to 115200 bits per second.
privilegelevel=administrator | operator | user administrator: Sets the maximum privilege level that are accepted on a serial over LAN channel, to Administrator.
operator: Sets the maximum privilege level that are accepted on a serial over LAN channel, to Operator.
user: Sets the maximum privilege level that are accepted on a serial over LAN channel, to User.
config=settodefault config=terminalmo de deletecontrol=outputdel | outputbkspspbksp handshakingcontrol=enabled | disabled inputlinesequence=cr | null
Takes the default configuration settings.
utputdel: BMC outputs a <del> character when
<bksp> or <del> is received.
outputbkspspbksp: BMC outputs a
<bksp><sp><bksp> character when <bksp> or
<del> is received.
enabled: Directs the BMC to output a character sequence that indicates when its input buffer is ready to accept another command.
disabled: Does not direct the BMC to output a character sequence that indicates when its input buffer is ready to accept another command.
cr: The console uses <CR> as a new line sequence.
96
name=value pair 1 config= name=value pair 2 config=user
Description lineediting=enabled | disabled newlinesequence=none| crlf | null | cr | lfcr | lf id=number enable=true | false id=number id=number enableserialoverlan=true | false id=number name=text id=number newpw=text confirmnewpw=text null: The console uses <NULL> as a new line sequence.
enabled: Enables line editing as a line is typed.
disabled: Disables line editing as a line is typed.
none: BMC does not use a termination sequence.
crlf: BMC uses <CR-LF> as a new line sequence when the BMC writes a new line to the console.
null: BMC uses <Null> as a new line sequence when the BMC writes a new line to the console.
cr: BMC uses <CR> as a new line sequence when the BMC writes a new line to the console.
lfcr: BMC uses <LF-CR> as a new line sequence when the BMC writes a new line to the console.
lf: BMC uses <LF> as a new line sequence when the BMC writes a new line to the console.
id=number: ID (in numeric format) of the user being configured.
enable=true: Enables the user.
enable=false: Disables the user.
id=number: ID (in numeric format) of the user being configured.
id=number: ID (in numeric format) of the user being configured.
name=text: Name of the user.
id=number: ID (in numeric format) of the user being configured.
newpw=text: New password of the user.
confirmnewpw=text: Confirm the new password.
97
name=value pair 1 config= name=value pair 2 Description id=number serialaccesslevel=administrator | operator | user | none id=number: ID (in numeric format) of the user being configured.
serialaccesslevel=administrator: User with an
ID has access privileges of an Administrator for the serial port channel.
serialaccesslevel=operator: User with an ID has access privileges of an Operator for the serial port channel.
serialaccesslevel=user: User with an ID has access privileges of a User for the serial port channel.
serialaccesslevel=none: User with an ID does not have access privileges for the serial port channel.
id=number lanaccesslevel=administrator | operator | user| none id=number: ID number of the user being configured.
lanaccesslevel=administrator: User with an ID has access privileges of an Administrator for the LAN channel.
lanaccesslevel=operator: User with an ID has access privileges of an Operator for the LAN channel.
lanaccesslevel=user: User with an ID has access privileges of a user for the LAN channel.
lanaccesslevel=none: User with an ID does not have access privileges for the LAN channel.
id=user id dracusergroup=admin
| poweruser | guest | custom | none id=user id: User ID of the user being configured.
dracusergroup=admin: Enables the
Administrator user privileges.
dracusergroup=poweruser: Enables the Power
User privileges.
dracusergroup=guest: Enables the Guest user privileges.
dracusergroup=custom: Enables the Custom
User privileges.
NOTE: For more information on
dracusergroup=custom, see Usage of
98
name=value pair 1 config= name=value pair 2 Description dracusergroup=none: Does not enable user privileges.
id=user id extipmiusergroup=admin | operator | readonly | custom | none
NOTE: extipmiusergroup user group is available only on Dell 10G blade systems.
id=user id: User ID of the user being configured.
extipmiusergroup=admin: Enables the
Administrator user privileges.
extipmiusergroup=operator: Enables the
Operator privileges.
extipmiusergroup=readonly: Enables the Read
Only privileges.
extipmiusergroup=custom: Enables the
Custom User privileges.
NOTE: It is recommended that you use the operator and readonly options for systems with iDRAC Enterprise. For more
.
extipmiusergroup=none: Does not enable user privileges.
Usage Of Dracusergroup=custom
The following table displays the usage of dracusergroup=custom.
Table 31. Valid Parameters of omconfig chassis remoteaccess config=user id=<user id> dracusergroup=custom or omconfig mainsystem remoteaccess config=user id=<user id> dracusergroup=custom name=valu e pair 1 name=value pair 2 config=user id=user id dracusergroup=custo m name=value pair 3 logindrac=true | false
Description true or false: Enables or disables logging into DRAC.
configuredrac=true | false true or false: Enables or disables configuration of DRAC.
configure users=true | false true or false: Enables or disables configuration of users.
clearlogs=true | false true or false: Enables or disables log clearance.
executeservercommands=tru e | false true or false: Enables or disables execution of server commands.
99
name=valu e pair 1 name=value pair 2 name=value pair 3 accessconsoleredir=true | false accessvirtualmedia=true | false testalerts=true | false
Description true or false: Enables or disables access to console redirection.
true or false: Enables or disables access to virtual media.
true or false: Enables or disables test alerts.
Usage of Extipmiusergroup=custom
The following table displays the usage of extipmiusergroup=custom:
Table 32. Usage Of extipmiusergroup=custom name=value pair 1 config=user name=value pair 2 id=user id extipmiusergroup=custo m
NOTE: extipmiusergroup user group is available only on the Dell 10G blade systems.
name=value pair 3 loginidrac=true | false id=user id configureidrac=true | false
Description true or false: Enables or disables logging into iDRAC.
true or false: Enables or disables configuration of iDRAC.
Omconfig Chassis Temps Or Omconfig Mainsystem Temps
Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for temperature probes. As with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. The system manufacturer sets the minimum and maximum failure threshold values.
NOTE: Threshold values that you can set vary from one system configuration to another.
Valid Parameters For Temperature Warning Thresholds
The following table displays the valid parameters for setting temperature warning thresholds:
Table 33. Valid Parameters For Omconfig Chassis Temps Or Omconfig Mainsystem Temps name=value pair index=<n> warnthresh=default
Description
Number of the probe or probe index (specify).
Sets the minimum and maximum warning threshold values to default.
100
name=value pair minwarnthresh=<n> maxwarnthresh=<n>
Description
Sets the minimum warning threshold values (one decimal place).
Sets the maximum warning threshold values (one decimal place).
Setting Minimum And Maximum Warning Threshold Values
To set both the upper and lower temperature warning threshold values to the recommended default value, type: omconfig chassis temps index=0 warnthresh=default or omconfig mainsystem temps index=0 warnthresh=default
You cannot default one value and set another. In other words, if you set the minimum warning threshold value to the default value, you are also selecting the default value for the maximum warning threshold value.
NOTE: The capabilities for managing sensors vary by systems.
Specify a value for minimum and maximum warning thresholds
To specify values for the temperature probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold value. In the following example, the probe that is being configured is probe 4: omconfig chassis temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7
or omconfig mainsystem temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7
When you issue the command and the system sets the values you specify, the following message is displayed:
Temperature probe warning threshold(s) set successfully.
Omconfig Chassis Volts Or Omconfig Mainsystem Volts
Use the omconfig chassis volts or omconfig mainsystem volts command to set voltage probe warning thresholds. As with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. The system manufacturer sets the minimum and maximum values for the failure thresholds.
Valid parameters for voltage warning thresholds
The following table displays the valid parameters for setting voltage warning threshold values.
NOTE: Threshold values that you can set vary from one system configuration to another.
Table 34. Valid Parameters Of Omconfig Chassis Volts Or Omconfig Mainsystem Volts name=value pair index=<n> warnthresh=default
Description
Probe index (specify).
Sets minimum and maximum warning threshold values to default.
101
name=value pair minwarnthresh=<n> maxwarnthresh=<n>
Description
Sets minimum warning threshold value (three decimal places).
Sets maximum warning threshold value (three decimal places).
Specify A Value For Minimum And Maximum Warning Thresholds
To specify values for the voltage probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values.
In the following example, the probe being configured is probe 0: omconfig chassis volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250
or omconfig mainsystem volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250
When you issue the command and the system sets the values you specify, the following message is displayed:
Voltage probe warning threshold(s) set successfully.
Omconfig Preferences
Use the omconfig preferences command to set system preferences. Use the command line to specify the user levels to access Server Administrator and to configure the Active Directory service.
Omconfig Preferences Cdvformat
Use the omconfig preferences cdvformat to specify the delimiters for separating data fields reported in the custom delimited format. The valid values for delimiters are: exclamation, semicolon, at, hash, dollar, percent, caret, asterisk, tilde, question, colon, comma, and pipe.
The following example shows how to set the delimiter for separating data fields to asterisk: omconfig preferences cdvformat delimiter=asterisk
Omconfig Preferences Dirservice
Use the omconfig preferences dirservice command to configure the Active Directory service. The
<productname>oem.ini file is modified to reflect these changes. If the "adproductname" is not present in the <productname>oem.ini file then a <computername>-<computername> refers to the name of the computer running Server Administrator and <productname> refers to the name of the product defined in omprv32.ini. For Server Administrator, the product name is "omsa".
Therefore, for a computer named "myOmsa" running Server Administrator, the default name is
"myOmsa–omsa". This is the name of Server Administrator defined in Active Directory by using the snapin tool. This name must match the name for the application object in Active Directory in order to find user privileges.
NOTE: This command is applicable only on systems running the Windows operating system.
The following table displays the valid parameters for the command:
102
Table 35. Valid Parameters Of Omconfig Preferences Dirservice name=value pair Description prodname=<text> Specifies the product to which you want to apply the Active Directory configuration changes. prodname refers to the name of the product defined in omprv32.ini. For
Server Administrator, it is "omsa".
enable=<true | false> true: Enables Active Directory service authentication support and the Active
Directory Login option on the login page.
false: Disables Active Directory service authentication support and the Active
Directory Login option on the login page. If the Active Directory Login option is not present, you can only login to the local machine accounts.
adprodname=<tex t>
Specifies the name of the product as defined in the Active Directory service. This name links the product with the Active Directory privilege data for user authentication.
Omconfig Preferences Messages
Use the omconfig preferences messages command to select the format of alert messages. The default format is traditional, which is the legacy format.
The following table lists the parameters you can use with this command.
Table 36. Valid Parameters Of Configuring Preferences Messages name=value pair 1 name=value pair 2 attribute=format setting=traditional | enhanced
Description traditional: Sets the alert message to traditional format.
enhanced: Sets the alert message to Enhanced
Event Messaging format. This is similar to the format available in iDRAC7.
For example, to set the message format to traditional use the following command: omconfig preferences messages format=traditional
Omconfig Preferences Useraccess
Depending on the policies of your organization, you may want to restrict the access that some user levels have to Server Administrator. The omconfig preferences useraccess command allows you to grant or withhold the right of users and power users to access Server Administrator.
The following table displays the valid parameters for the command:
103
Table 37. Enabling User Access For Administrators, Power Users, And Users
Command omconfig preferences useraccess enable=user omconfig preferences useraccess enable=poweruser omconfig preferences useraccess enable=admin
Result
Grants Server Administrator access to Users, Power Users, and Administrators.
Grants Server Administrator access to Power Users and
Administrators.
Grants Server Administrator access to Administrators only.
Description
Least restrictive form of user access.
Excludes user level access only.
Most restrictive form of user access.
Omconfig Preferences Logging
Use the omconfig preferences logging command for filtering the OS logs using the attributes.
Table 38. Valid Parameters Of Omconfig Preferences Logging name=value pair 1 attribute=oslogfilter name=value pair 2 logcrit=true|false logwarn=true| false loginfo=true|false attribute=archiveesmlog setting=Enable|Disable
Description
Specify at least one of the three attributes (critical, warning or informational), else an error message is displayed. A command log entry is created after running the omconfig command. The OS logging settings persist on Server
Administrator restart and upgrade.
omconfig preferences logging attribute=oslogfilter logcrit=<true|false> logwarn=<true|false> loginfo=<true|false>
NOTE: The OS logging filter command is applicable when the OS logging filter component is installed.
Enabling the command allows you to create an automatic backup of
ESM Logs. After the backup is created, ESM logs of the Server
Administrator and the SEL entries of iDRAC/BMC are cleared. The process is repeated whenever the logs are full.
The backup files are:
Windows: <Install_root>\omsa\log
\omsellog.xml
104
name=value pair 1 name=value pair 2 Description
Linux and ESXi:
<Install_root>/var/log/ openmanage/omsellog.xml
NOTE: This command is applicable only on 10th and
11th generation of
PowerEdge servers. On Dell’s
12th generation of
PowerEdge servers and later, iDRAC provides capability of automatic clear of log entries and file backup. Only latest version of the backup XML file is available in the mentioned locations.
An example command set only to remove the critical severities is as follows: omconfig preferences logging attribute=oslogfilter logcrit=false
An example command set to enable the automatic backup of ESM logs.
omconfig preferences logging attribute=archiveesmlog setting=Enable
Omconfig preferences webserver
Use the omconfig preferences webserver command to set the encryption levels of the Server
Administrator web server, configure the URL launch point in the Server Administrator web server environment, and to set the JRE version for the Server Administrator.
The following table displays the name=value pairs you can use with this command:
Table 39. Valid Parameters Of Omconfig Preferences Webserver name=value pair 1 attribute=sslencryption name=value pair 2 setting=autonegotiate |
128bitorhigher
Description autonegotiate: Sets the encryption levels automatically based on your web browser settings.
128bitorhigher: Sets the encryption levels to 128-bit or higher.
attribute=seturl host=<string> port=<value>
NOTE: This attribute is deprecated in the future releases, use ciphers instead.
Enables you to configure the
Distributed Web Server (DWS) URL
105
name=value pair 1 attribute=signalgorithm attribute=setjre attribute=exportcsr attribute=gennewcert name=value pair 2 setting=MD5 | SHA1 | SHA256 |
SHA512 jreversion=bundled | value
Description launch point, for accessing the management node. This command is used when Server
Administrator Instrumentation
Service and Remote Enablement are installed on the same system and the Server Administrator GUI is accessed using the DWS URL.
NOTE: This command is not supported if the web server is present on the same system.
MD5: Sets the key signing algorithm to MD5.
SHA1: Sets the key signing algorithm to SHA1.
SHA256: Sets the key signing algorithm to SHA256.
SHA512: Sets the key signing algorithm to SHA512.
bundled: Sets the version bundled with Server Administrator. This is the default value.
value: Sets the provided version, which is available on the system.
To obtain the available versions on the system, type omreport preferences webserver attribute=getjrelist. For
more details, see omreport preferences webserver .
N/A Exports a Certificate Signing
Request (CSR) file. The exported .csr file is saved at
<Server Administrator installation directory>\apache-tomcat\temp.
cn=<common name> org=<organization name> ou=<organization unit name> location=<location name> state=<state name> country=<country name> validity=<validity> keysize=<512 |
1024 | 2048> algorithm=<MD5 |
SHA1 | SHA256 | SHA512> webserverrestart=<true | false>
Creates a new self-signed certificate for the SSL communication between the server running Server
Administrator and the web server.
106
name=value pair 1 attribute=uploadcert name=value pair 2 Description
NOTE: The country name
(country name) must be of two characters, and validity
(validity) must be in days.
For country names, see the table, Country names and codes, provided later in this section. The validity, keysize, and algorithm parameters are optional. If you do not set any value for the optional parameters,
Server Administrator assigns default values to the optional parameters. The default values of validity, keysize, and algorithm are 1095, 2048, and SHA512 respectively. Restarting Server
Administrator web server is optional, but the generated certificate comes to effect only after restarting the web server.
certfile=<path of the certificate
file> type=<pkcs12> password=<password of the
certificate file> webserverrestart=true | false
Allows you to import a PKCS#12 keystore that replaces the private key and certificate used in Server
Administrator web server.
PKCS#12 is public keystore that contains a private key and the certificate for a web server. Server
Administrator uses the Java
KeyStore (JKS) format to store the
SSL certificates and its private key.
Importing a PKCS#12 keystore to
Server Administrator deletes the keystore entries, and imports a private key and certificate entries to the Server Administrator JKS.
NOTE: If you are importing a
PKCS#12 keystore, specify the type and password of the certificate. Restarting Server
Administrator web server is optional, but the uploaded certificate comes to effect only after restarting the web server.
NOTE: An error message is displayed if you either type an invalid PKCS file name or an incorrect password.
107
name=value pair 1 attribute=<ciphers> attribute=<sslprotocol> attribute=<port> attribute=<ipaddress> attribute=<sessiontimeout> name=value pair 2 setting=<valid ciphers text value>
Description
Allows you to choose the ciphers that support the web server while configuring. SSL provides a secure connection between the web server and the browser. The connection service does not start if an invalid cipher suite is set.
NOTE: If an incorrect cipher value is set and the connection service fails to start, use the CLI command prompt or manually set the valid ciphers and restart the connection service.
setting=<valid sslprotocol values are TLSv1| TLSv1.1| TLSv1.2|
TLSv1, TLSv1.1| TLSv1.1, TLSv1.2|
TLSv1, TLSv1.1, TLSv1.2
Allows you to set the web server
SSL protocols configuration from the valid values. The changes to take effect after web server restart.
setting=<valid port value> Sets the number of secure ports that you want Server Administrator to use. The port value range from
1024 to 65535. The default port for Server Administrator is 1311.
setting=<valid Binding IPAddress value>
Sets by default the web server to incoming browser requests on ALL
IP addresses. However, for increased security you can specify a single IP address or, ALL IP addresses. An error message is displayed on an invalid entry of the configurable Bind List of IP
Address. For the changes to take effect, restart the web server.
setting=<valid Session Timeout value between 1– 30>
Allows Server Administrator to time-out if there is no user input for a specified number of minutes.
Users whose sessions time-out must log in again to continue.
An example command to set the URL launch point is as follows: omconfig preferences webserver attribute=seturl host=<name, ip, fqdn> port=<number>
The host input must contain a valid IPv4 or IPv6 address, or a valid host name.
An example command to set the signing algorithm value is as follows: omconfig preferences webserver attribute=signalgorithm setting=MD5
108
An example command to set the JRE versions is as follows: omconfig preferences webserver attribute=setjre jreversion=<bundled | value>
An example command to export a Certificate Signing Request (CSR) is as follows: omconfig preferences webserver attribute=exportcsr
The command creates a file of the format xxxx.csr in the <Server Administrator installation directory>
\apache-tomcat\temp folder.
An example command to create a web server certificate is as follows: omconfig preferences webserver attribute=gennewcert cn=HostName org=dell ou=ESG location=RoundRock state=TX country=US validity=300 keysize=2048 algorithm=SHA512 webserverrestart=true
An example command to upload a certificate on the Server Administrator web server is as follows: omconfig preferences webserver attribute=uploadcert certfile=C:/xyz.crt webserverrestart=true
An example command to upload a certificate with a PKCS#12 keystore on the Server Administrator web server is as follows: omconfig preferences webserver attribute=uploadcert certfile=C:/xyz.pfx type=pkcs12 password=abc webserverrestart=true
Table 40. Country names and codes
Country Names
AFGHANISTAN
Codes
AF
ALBANIA
ALGERIA
AL
DZ
AMERICAN SAMOA
ANDORRA
ANGOLA
ANGUILLA
AS
AD
AO
AI
ANTARCTICA
ANTIGUA AND BARBUDA
ARGENTINA
ARMENIA
ARUBA
AUSTRALIA
AQ
AG
AR
AM
AW
AU
109
Country Names
AUSTRIA
AZERBAIJAN
BAHAMAS
BAHRAIN
BANGLADESH
BARBADOS
BELARUS
BELGIUM
BELIZE
BENIN
BERMUDA
BHUTAN
BOLIVIA
BOSNIA AND HERZEGOWINA
BOTSWANA
BOUVET ISLAND
BRAZIL
BRITISH INDIAN OCEAN TERRITORY
BRUNEI DARUSSALAM
BULGARIA
BURKINA FASO
BURUNDI
CAMBODIA
CAMEROON
CANADA
110
BT
BO
BA
BW
BE
BZ
BJ
BM
BH
BD
BB
BY
Codes
AT
AZ
BS
BG
BF
BI
KH
BV
BR
IO
BN
CM
CA
Country Names
CAPE VERDE
CAYMAN ISLANDS
CENTRAL AFRICAN REPUBLIC
CHAD
CHILE
CHINA
CHRISTMAS ISLAND
COCOS (KEELING) ISLANDS
COLOMBIA
COMOROS
CONGO
CONGO, THE DEMOCRATIC REPUBLIC OF THE
COOK ISLANDS
COSTA RICA
COTE D'IVOIRE
CROATIA (local name: Hrvatska)
CYPRUS
CZECH REPUBLIC
DENMARK
DJIBOUTI
DOMINICA
DOMINICAN REPUBLIC
EAST TIMOR
ECUADOR
EGYPT
CD
CK
CR
CI
CC
CO
KM
CG
TD
CL
CN
CX
Codes
CV
KY
CF
DJ
DM
DO
TP
HR
CY
CZ
DK
EC
EG
111
GAMBIA
GEORGIA
GERMANY
GHANA
GIBRALTAR
GREECE
GREENLAND
GRENADA
GUADELOUPE
GUAM
Country Names
EL SALVADOR
EQUATORIAL GUINEA
ERITREA
ESTONIA
ETHIOPIA
FALKLAND ISLANDS (MALVINAS)
FAROE ISLANDS
FIJI
FINLAND
FRANCE
FRANCE, METROPOLITAN
FRENCH GUIANA
FRENCH POLYNESIA
FRENCH SOUTHERN TERRITORIES
GABON
112
GF
PF
TF
GA
FR
FX
FJ
FI
EE
ET
FK
FO
Codes
SV
GQ
ER
GI
GR
GL
GD
GM
GE
DE
GH
GP
GU
Country Names
GUATEMALA
GUINEA
GUINEA-BISSAU
GUYANA
HAITI
HEARD AND MC DONALD ISLANDS
HOLY SEE (VATICAN CITY STATE)
HONDURAS
HONG KONG
HUNGARY
ICELAND
INDIA
INDONESIA
IRAQ
IRELAND
ISRAEL
ITALY
JAMAICA
JAPAN
JORDAN
KAZAKHSTAN
KENYA
KIRIBATI
KOREA, REPUBLIC OF
KUWAIT
IQ
IE
IN
ID
HN
HK
HU
IS
GY
HT
HM
VA
Codes
GT
GN
GW
JO
KZ
KE
KI
IL
IT
JM
JP
KR
KW
113
Country Names
KYRGYZSTAN
LAO PEOPLE'S DEMOCRATIC REPUBLIC
LATVIA
LEBANON
LESOTHO
LIBERIA
LIBYAN ARAB JAMAHIRIYA
LIECHTENSTEIN
LITHUANIA
LUXEMBOURG
MACAU
MACEDONIA, THE FORMER YUGOSLAV REPUBLIC OF
MADAGASCAR
MALAWI
MALDIVES
MALTA
MARSHALL ISLANDS
MARTINIQUE
MAURITANIA
MAURITIUS
MAYOTTE
MEXICO
MICRONESIA, FEDERATED STATES OF
MOLDOVA, REPUBLIC OF
MONACO
114
MK
MG
MW
MV
LI
LT
LU
MO
LR
LY
LB
LS
Codes
KG
LA
LV
MY
YT
MX
FM
MT
MH
MQ
MR
MD
MC
Country Names
MONGOLIA
MONTSERRAT
MOROCCO
MOZAMBIQUE
MYANMAR
NAMIBIA
NAURU
NEPAL
NETHERLANDS
NETHERLANDS ANTILLES
NEW CALEDONIA
NEW ZEALAND
NICARAGUA
NIGER
NIGERIA
NIUE
NORFOLK ISLAND
NORTHERN MARIANA ISLANDS
NORWAY
OMAN
PAKISTAN
PALAU
PALESTINIAN TERRITORY, OCCUPIED
PANAMA
PAPUA NEW GUINEA
NZ
NI
NE
NG
NP
ML
AN
NC
MZ
MM
NA
NR
Codes
MN
MS
MA
OM
PK
PW
PS
NU
NF
MP
NO
PA
PG
115
Country Names
PARAGUAY
PERU
PHILIPPINES
PITCAIRN
POLAND
PORTUGAL
PUERTO RICO
QATAR
REUNION
ROMANIA
RUSSIAN FEDERATION
RWANDA
SAINT KITTS AND NEVIS
SAINT LUCIA
SAINT VINCENT AND THE GRENADINES
SAMOA
SAN MARINO
SAO TOME AND PRINCIPE
SAUDI ARABIA
SENEGAL
SEYCHELLES
SIERRA LEONE
SINGAPORE
SLOVAKIA (Slovak Republic)
SLOVENIA
116
RW
KN
LC
VC
QA
RE
RO
RU
PN
PL
PT
PR
Codes
PY
PE
PH
SK
SI
SN
SC
SL
SG
WS
SM
ST
SA
Country Names
SOLOMON ISLANDS
SOMALIA
SOUTH AFRICA
SOUTH GEORGIA AND THE SOUTH SANDWICH ISLANDS
SPAIN
SRI LANKA
ST. HELENA
ST. PIERRE AND MIQUELON
SURINAME
SVALBARD AND JAN MAYEN ISLANDS
SWAZILAND
SWEDEN
SWITZERLAND
TAIWAN
TAJIKISTAN
TANZANIA, UNITED REPUBLIC OF
THAILAND
TOGO
TOKELAU
TONGA
TRINIDAD AND TOBAGO
TUNISIA
TURKEY
TURKMENISTAN
TURKS AND CAICOS ISLANDS
SE
CH
TW
TJ
SJ
SZ
PM
SR
GS
ES
LK
SH
Codes
SB
SO
ZA
TO
TT
TN
TR
TZ
TH
TG
TK
TM
TC
117
Country Names
TUVALU
UGANDA
UKRAINE
UNITED ARAB EMIRATES
UNITED KINGDOM
UNITED STATES
UNITED STATES MINOR OUTLYING ISLANDS
URUGUAY
UZBEKISTAN
VANUATU
VENEZUELA
VIETNAM
VIRGIN ISLANDS (BRITISH)
VIRGIN ISLANDS (U.S.)
WALLIS AND FUTUNA ISLANDS
WESTERN SAHARA
YEMEN
YUGOSLAVIA
ZAMBIA
ZIMBABWE
Omconfig System Or Omconfig Servermodule
Use the omconfig system or omconfig servermodule commands to clear logs, determine how various shutdown actions occur, set initial values or edit values for cost of ownership information, and determine how to respond to a hung operating system.
VN
VG
VI
WF
UY
UZ
VU
VE
EH
YE
YU
ZM
ZW
AE
GB
US
UM
Codes
TV
UG
UA
118
Omconfig System Alertaction Or Omconfig Servermodule Alertaction
You can use the omconfig system alertaction or omconfig servermodule alertaction command to determine how Server Administrator responds when a component has a warning or failure event.
Defining alert actions
An alert action is an action that you specify for the system to take when specified conditions are met.
Alert actions determine in advance what actions to take for warning or failure events on intrusion, fans, temperatures, voltages, power supplies, memory, and redundancy.
For example, if a fan probe on the system reads a fan RPM of 300 and your minimum warning threshold value for that fan probe is 600 RPM, then the system generates a fan probe warning. Alert action settings determine how users are notified of this event. You can also configure alert actions for temperature, voltage, and probe readings that fall within the warning or failure range.
Syntax For Setting Alert Actions
Setting an alert action requires two name=value pairs. The first name=value pair is the event type. The second name=value pair is the action to take for this event. For example, in the command: omconfig system alertaction event=powersupply broadcast=true or omconfig servermodule alertaction event=powersupply broadcast=true
The event is a power supply failure and the action is to broadcast a message to all Server Administrator users.
Available alert actions
The following table displays the alert actions for each component that allows you to configure an alert action:
Table 41. Valid Parameters of Alert Actions For Warning and Failure Events
Alert Action Setting alert=true | false
Description true: Enables the system's console alert. When enabled, the monitor attached to the system from which you are running Server Administrator displays a visual alert message.
false: Disables the system's console alert.
broadcast=true | false true: Enables a message or alert to broadcast to all users who have an active terminal (or Remote
Desktop) session (Windows) or to operators that have an active shell on the local system (Linux.) false: Disables alert broadcasts.
clearall=true Clears all actions for this event.
119
Alert Action Setting execappath=<string>
Description
Sets the fully qualified path and file name of the application you want to execute in case of an event for the component described in this window.
NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this alert action setting.
Disables the executable application.
execapp=false
Components and events for alert actions
The following table provides the events for which you can set alert actions. Components are listed in alphabetical order, except that warning events always precede failure events for a component.
Table 42. Valid Parameters Of Events for Alert Actions
Event Name event=batterywarn event=batteryfail event=fanwarn
Description
Sets actions when a battery probe detects a warning value.
Sets actions when a battery probe detects a failure value.
Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull event=intrusion
Sets actions when a hardware log is full.
Sets actions when a chassis intrusion event is detected.
event=memprefail event=memfail
Sets actions when a memory probe detects a prefailure value.
Sets actions when a memory probe detects a failure value.
event=systempeakpower Sets actions when a power consumption probe detects peak power value.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail event=powersupply
Sets actions when a power consumption probe detects a failure value.
Sets actions when a power supply probe detects a failure value.
event=powersupplywarn Sets actions when a power supply probe detects a warning value.
event=processorwarn Sets actions when a processor probe detects a warning value.
event=processorfail event=redundegrad event=redunlost event=tempwarn
Sets actions when a processor probe detects a failure value.
Sets actions when a redundant component becomes inoperative, resulting in less than full redundancy for that component.
Sets actions when one or more redundant components become inoperative, resulting in a lost or a "no redundant components working" condition for that component.
Sets actions when a temperature probe detects a warning value.
120
Event Name event=tempfail event=voltwarn event=voltfail event=watchdogasr event=removableflashme diapresent event=removableflashme diaremoved event=removableflashme diafail event=storagesyswarn event=storagesysfail event=storagectrlwarn event=storagectrlfail event=pdiskwarn event=pdiskfail
Description
Sets actions when a temperature probe detects a failure value.
Sets actions when a voltage probe detects a warning value.
Sets actions when a voltage probe detects a failure value.
Sets actions that Server Administrator performs on the next system startup after a watchdog Automatic System Recovery (ASR) is performed for a hung operating system.
Sets actions that Server Administrator performs when the system detects a removable flash media.
Sets actions that Server Administrator performs when a removable flash media is removed.
Sets actions that Server Administrator performs when a removable flash media fails.
Sets actions when a storage system detects a warning value.
Sets actions when a storage system detects a failure value.
Sets actions when a storage controller detects a warning value.
Sets actions when a storage controller detects a failure value.
Sets actions when a physical disk detects a warning value.
Sets actions when a physical disk detects a failure value.
event=vdiskwarn event=vdiskfail
Sets actions when a virtual disk detects a warning value.
Sets actions when a virtual disk detects a failure value.
event=enclosurewarn Sets actions when an enclosure detects a warning value.
event=enclosurefail event=storagectrlbatteryw arn
Sets actions when an enclosure detects a failure value.
Sets actions when a storage controller battery detects a warning value.
NOTE: This event is not available on blade systems.
event=storagectrlbatteryf ail
Sets actions when a storage controller battery detects a failure value.
NOTE: This event is not available on blade systems.
Example Set Alert Action Commands
The following are examples of valid example commands. For each successful command issued, the following message is displayed:
Alert action(s) configured successfully.
Example Current Probe Actions
To disable system console alert if a current probe detects a warning event, type: omconfig system alertaction event=currentwarn alert=false
121
or omconfig servermodule alertaction event=currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type: omconfig system alertaction event=currentfail broadcast=true or omconfig servermodule alertaction event=currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type: omconfig system alertaction event=fanfail alert=true or omconfig servermodule alertaction event=fanfail alert=true
Example chassis intrusion actions
To clear all alert actions for chassis intrusion, type: omconfig system alertaction event=intrusion clearall=true or omconfig servermodule alertaction event=intrusion clearall=true
Commands for clearing logs
You can use the omconfig system or omconfig servermodule command to clear the following logs: the alert log, command log, and hardware or ESM log.
To clear the contents of the alert log, type: omconfig system alertlog action=clear or omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing the command log resolves this condition.
To clear the contents of the command log, type: omconfig system cmdlog action=clear or omconfig servermodule cmdlog action=clear
To clear the contents of the ESM log, type: omconfig system esmlog action=clear or omconfig servermodule esmlog action=clear
NOTE: For more information about alert messages, see the Dell OpenManage Server Administrator
Messages Reference Guide at dell.com/support/manuals.
122
Omconfig system pedestinations or omconfig servermodule pedestinations
Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP addresses for alert destinations.
The following table displays the valid parameters for the command.
NOTE: You can either specify the index and IP address as parameters together or you can set only the community string as a parameter.
NOTE: Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address. On 12G systems with iDRAC7 specific versions, the index can accept IPv4, IPv6, or FQDN.
Table 43. Valid Parameters Of Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations name=Value Pair Description destenable=true | false true: Enables an individual platform event filter destination after a valid IP address has been set.
false: Disables an individual platform event filter.
index=number Sets the index for the destination.
ipaddress=<ipv4 address
| ipv6 address | fqdn>
Sets the IP address for the destination.
NOTE: On 12G systems with iDRAC7 specific versions, ipaddress can also be a Fully Qualified Domain Name (FQDN).
communitystr=text Sets the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station.
Omconfig system platformevents or omconfig servermodule platformevents
Use the omconfig system platformevents or omconfig servermodule platformevents command to configure shutdown action, if any, taken for a specific platform event. You can also enable or disable platform event filter alert generation.
CAUTION: If you set a platform event shutdown action to anything other than none or power
reduction, the system is forcefully shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first shutting down the operating system or any of the applications running on your system.
The following table displays the valid parameters for the command.
NOTE: Alert settings are mutually exclusive and you can set one at a time only. The action settings are also mutually exclusive and you can set one at a time only. However, alert and action settings are not mutually exclusive of each other.
Table 44. Parameters For Alert Action Command
Action action=disable action=enable
Description
Disables the SNMP alert.
Enables the SNMP alert.
123
Action action=none
Description
Takes no action when the system is hung or has crashed.
action=powercycle Turns off the electrical power to the system, pauses, turns the power on, and reboots the system.
action=poweroff action=powerreduc tion
Turns off the electrical power to the system.
Reduces the processor speed until the power consumption comes down and reaches below the warning threshold. If the system power consumption stays below the warning threshold, increases the processor speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems earlier than PowerEdge 11G systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs
BIOS checks, and reloads the operating system.
Components and events of platform events
The following table lists the components and the events for which you can set platform events.
Components are listed in alphabetical order, except that warning events always precede failure events for a component.
Table 45. Valid Parameters Of Omconfig System Platformevents
Event Name alertsenable=true | false
Description true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual platform event filter alert settings. For a platform event filter to generate an alert, both the individual alert and the global event alert are enabled.
event=batterywarn event=batteryfail event=discretevolt event=fanfail event=hardwarelogfail event=intrusion event=powerwarn
Sets action or enables or disables alert generation when a battery device detects that the battery is pending a failure condition.
Sets action or enables or disables alert generation when a battery device detects that the battery has failed.
Sets action or enables or disables alert generation when a discrete voltage probe detects that the voltage is too low for proper operation.
Sets action or enables or disables alert generation when a fan probe detects that the fan is running too slow or not at all.
Enables or disables alert generation when a hardware log detects a failure value.
Sets action or enables or disables alert generation when a chassis is opened.
Sets action or enables or disables alert generation when a power device probe detects that the power supply, voltage regulator module, or DC to DC converter is pending a failure condition.
124
Event Name event=powerabsent event=powerfail event=processorwarn event=processorfail event=processorabsent
Description
Sets action or enables or disables alert generation when a processor probe detects that the power supply is absent.
Sets action or enables or disables alert generation when a power device probe detects that the power supply, voltage regulator module, or DC to DC converter has failed.
Sets action or enables or disables alert generation when a processor probe detects that the processor is running at less than peak performance or speed.
Sets action or enables or disables alert generation when a processor probe detects that the processor has failed.
Sets action or enables or disables alert generation when a processor probe detects that the processor is absent.
event=redundegrad event=redunlost
Sets action or enables or disables alert generation when the system fans and/or power supplies become inoperative, resulting in less than full redundancy for that component.
Sets action or enables or disables alert generation when the system fans and/or power supplies become inoperative, resulting in a lost or a
no redundant components working condition for that component.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
Sets actions when a power consumption probe detects a failure value.
event=systempowerfail event=tempwarn Sets action or enables or disables alert generation when a temperature probe detects that the temperature is approaching the maximum high or low limits.
event=removableflashmediapre sent
Sets actions that Server Administrator performs when the system detects a removable flash media.
event=removableflashmediawa rn
Sets actions that Server Administrator performs when a removable flash media warning is displayed.
event=removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails.
event=tempfail Sets action or enables or disables alert generation when a temperature probe detects that the temperature is either too high or low for proper operation.
event=voltfail event=intdualsdcardcritical
Sets action or enables or disables alert generation when a voltage probe detects that the voltage is too low for proper operation.
Sets actions that Server Administrator performs when an internal dual
SD card critical event occurs.
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual
SD card warning is displayed.
125
Event Name event=intdualsdcardabsent
Description
Sets actions that Server Administrator performs when an internal dual
SD card is not available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual SD card is lost.
event=watchdogasr Enables or disables alert generation configured by the ASR when the system has hung or is not responding.
Omconfig system snmptraptest or omconfig servermodule snmptraptest
Use the omconfig system snmptraptest or omconfig servermodule snmptraptest command to send the snmp test trap to the destination address if Server Administrator SNMP component is configured in the configuration file.
The following table displays the valid parameters for the command:
Table 46. Parameters For Alert Action Command
Action dest=<ipv4 address
| ipv6 address |
fqdn>
Description
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMWare ESXi.
Omconfig System Events Or Omconfig Servermodule Events
Use the omconfig system events or omconfig servermodule events command to enable and disable
SNMP traps for the components on your system.
NOTE: Not all event types are present on the system.
There are four parameters in the name=value pair component of the omconfig system events command:
• Source
• Type
• Severity
• Index
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event notification for the system’s components.
omconfig system events source=snmptraps or omconfig servermodule events source=snmptraps
Type
Type refers to the name of the component(s) involved in the event. The following table displays the valid parameters for system event types.
126
Table 47. System Event Type Parameters name=value pair type=accords type=battery type=all type=fanenclosures type=fans type=intrusion type=log
Description
Configures events for AC power cords.
Configures events for battery.
Configures events for all device types.
Configures events for fan enclosures.
Configures events for fans.
Configures events for chassis intrusion.
Configures events for logs.
type=memory type=powersupplies type=redundancy type=systempower
Configures events for memory.
Configures events for power supplies.
Configures events for redundancy.
Configures events for system power.
type=temps type=volts
Configures events for temperatures.
Configures events for voltages.
type=systempeakpower Configures events for system peak power.
type=removableflashme dia
Configures events for removable flash media.
Severity
In the context of configuring events, severity determines how severe an event is, before Server
Administrator notifies you of the event for a component type. When there are multiple components of the same type in the same system chassis, you can specify whether you want notification for event severity according to the number of the component by using the index=<n> parameter. The following table displays the valid severity parameters.
Table 48. System Event Severity Parameters
Command omconfig system events type=<component name> severity=info or omconfig servermodule events type=<component name> severity=info omconfig system events type=<component name> severity=warning or omconfig servermodule events type=<component name> severity=warning
Result
Enables notification for informational, warning, and critical events.
Enables notification for warning and critical events.
Description
Least restrictive form of event notification.
Omits informational event notification, for example, when a component returns to normal status.
127
Command omconfig system events type=<component name> severity=critical or omconfig servermodule events type=<component name> severity=critical omconfig system events type=<component name> severity=none or omconfig servermodule events type=<component name> severity=none
Result
Enables notification for critical events only.
Disables event notification.
Description
Restrictive form of event notification.
No event notification.
Index
Index refers to the number of an event for a particular component. Index is an optional parameter. When you omit the index parameter, events are configured for all components of the specified type, such as all fans. For example, when a system contains more than one fan, you can enable or disable event notification for a particular fan. An example command is as follows: omconfig system events type=fan index=0 severity=critical or omconfig servermodule events type=fan index=0 severity=critical
As a result of the example command, Server Administrator sends an SNMP trap only when the first fan in the system chassis (index 0) has reached critical fan RPMs.
Omconfig System Webserver Or Omconfig Servermodule Webserver
Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the
Web server. The following table displays the valid parameters for the command.
Table 49. Valid Parameters Of Web Server Configuration name=value pair Description action=start Starts the Web server.
action=stop action=restart
Stops the Web server.
Restarts the Web server.
Omconfig System Recovery Or Omconfig Servermodule Recovery
Use the omconfig system recovery or omconfig servermodule recovery command to set the action when the operating system hangs or crashes. You can also set the number of seconds that must pass before the system is considered to have a hung operating system. The following table lists the valid parameters for the command
NOTE: The upper and lower limits for the timer are dependent on the system model and configuration.
128
Table 50. Valid Parameters Of Omconfig System Recovery Or Omconfig Servermodule Recovery name=value pair action=none
Description
Takes no action when the operating system is hung or has crashed.
action=reboot Shuts down the operating system and initiates system startup, performing BIOS checks, and reloading the operating system.
Turns off electrical power to the system.
action=poweroff action=powercycle Turns off electrical power to the system, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to re-initialize system components such as hard drives.
timer=<n> Number of seconds that must pass before the system is considered to have a hung operating system (from 20 seconds to 480 seconds).
Example Recovery Commands
To set the action on hung operating system detection to powercycle, type: omconfig system recovery action=powercycle or omconfig servermodule recovery action=powercycle
To set the system to hang for 120 seconds, before a recovery action is initiated, type: omconfig system recovery timer=120 or omconfig servermodule recovery timer=120
Omconfig System Shutdown Or Omconfig Servermodule Shutdown
Use the omconfig system shutdown or omconfig servermodule shutdown command to determine the way in which the system shuts down. During system shutdown, the default is to shut down the operating system before powering off the system. Shutting down the operating system first closes down the file system before powering the system down. If you do not want to shut down the operating system first, use the osfirst=false parameter.
NOTE: The parameter osfirst=false is not available on 13G and later systems. By default, on 13G and later systems, the operating system shuts down before turning off the server during a remote shutdown.
The following table displays the valid parameters for the command.
Table 51. Valid Parameters Of System Shutdown name=value pair Description action=reboot Shuts down the operating system and initiates system startup, performing BIOS checks and reloading the operating system.
action=poweroff Turns off the electrical power to the system.
129
name=value pair Description action=powercycl e
Turns off the electrical power to the system, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to re-initialize system components such as hard drives.
osfirst=true | false true: Closes the file system and exits the operating system before turning off the server.
false: Does not close the file system or shuts down the operating system before turning off the server.
NOTE: This command osfirst=false is not available on 13G and later systems.
By default, on 13G and later systems, the operating system shuts down before turning off the server during a remote shutdown.
Example Shutdown Commands
To set the shutdown action to reboot, type: omconfig system shutdown action=reboot or omconfig servermodule shutdown action=reboot
To bypass operating system shutdown before the system is powered off, type: omconfig system shutdown action=reboot osfirst=false or omconfig servermodule shutdown action=reboot osfirst=false
NOTE: The parameter osfirst=false is not available on 13G and later systems. By default, on 13G and later systems, the operating system shuts down before turning off the server during a remote shutdown.
Omconfig System Thrmshutdown Or Omconfig Servermodule
Thrmshutdown
Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure a thermal shutdown action. You can configure the system for a thermal shutdown when a temperature probe detects a temperature probe warning or failure event.
The following table displays the valid parameters for the command:
Table 52. Valid Parameters Of Thermal Shutdown name=value pair severity=disabled | warning | failure
Description disabled: Disable thermal shutdown. An administrator must intervene.
warning: Perform a shutdown when a temperature warning event is detected. A warning event occurs when any temperature probe inside a chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature warning threshold value.
130
name=value pair Description failure: Perform a shutdown when a temperature failure event is detected. A failure event occurs when any temperature probe inside a chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature failure threshold value.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure event, type: omconfig system thrmshutdown severity=failure or omconfig servermodule thrmshutdown severity=failure
To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown, type: omconfig system thrmshutdown severity=disabled or omconfig servermodule thrmshutdown severity=disabled
131
5
Omconfig System Or Servermodule
Assetinfo: Editing Cost Of Ownership
Values
The omconfig system assetinfo or omconfig servermodule assetinfo command helps you to edit a comprehensive set of parameters that make up the total cost of ownership of the system. This section explains the parameters that are reported and configured under the omconfig system assetinfo or omconfig servermodule assetinfo command.
Using the omconfig system assetinfo or omconfig servermodule assetinfo command, you can set governing values for configurable objects. Examples of assetinfo configuration capabilities include setting values for system owner, purchase price, details of any lease that is in effect, depreciation methods and rates, and location of the system, warranty and extended warranty duration, outsourcing details, and service level agreement.
NOTE: Power Users and Administrators can add and edit asset information.
The following table lists the systems on which omconfig commands are applicable:
Table 53. System Availability for the omconfig Command
Command Level 1 omconfig
Command Level 2 servermodule mainsystem system chassis
Applicable to
Blade systems
Blade systems
Rack and Tower systems
Rack and Tower systems
Adding acquisition information
Acquisition refers to the facts about a business entity's purchase or lease of a system. Use the omconfig system assetinfo info=acquisition or omconfig servermodule assetinfo info=acquisition command to add detailed information about the purchase or lease of a system. The following table displays the valid parameters for the command:
132
Table 54. Valid Parameters Of omconfig system assetinfo info=acquisition or omconfig servermodule assetinfo info=acquisition
Command
Level 1 omconfig
Command
Level 2 system or servermodule
Command
Level 3 assetinfo
Name= Value
Pair 1 info=acquisiti on
Name= Value Pair 2 costcenter=<text> expensed=yes | no installdate=<mmddyy
> ponum=<n> purchasecost=<n> purchasedate=<mmd
dyy> signauth=<text> waybill=<n>
Description
The name or code for the business entity that acquired the system.
Whether the system is charged to a specific purpose or department such as research and development or sales.
Date the system was put to service.
Number of the document that authorized payment for the system.
Price the owner paid for the system.
Date the owner purchased the system.
Name of the person who approved the purchase or the service call on the system.
Receipt from the carrier for the goods received.
133
Example command for adding acquisition information
To provide a value for an acquisition parameter, type a command of the form: omconfig system assetinfo info=acquisition <name=value pair 2> or omconfig servermodule assetinfo info=acquisition
<name=value pair 2>. For example, type: omconfig system assetinfo info=acquisition purchasedate=122101 or omconfig servermodule assetinfo info=acquisition purchasedate=122101
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all of the parameters for name=value pair 2 belong to the same name=value pair 1. For example, to type more than one parameter value for info=acquisition, use the following example as a syntax guide: omconfig system assetinfo info=acquisition purchasecost=5000 waybill=123456 installdate=120501 purchasedate=050601 ponum=9999 signauth="John
Smith" expensed=yes costcenter=finance or omconfig servermodule assetinfo info=acquisition purchasecost=5000 waybill=123456 installdate=120501 purchasedate=050601 ponum=9999 signauth="John
Smith" expensed=yes costcenter=finance
The following message is displayed:
Asset information set successfully.
Adding depreciation information
Depreciation is a set of methods for computing the devaluation of the asset over time. For example, the depreciation of a system that is expected to have a useful life of 5 years is 20 percent. Use the omconfig system assetinfo info=depreciation or omconfig servermodule assetinfo info=depreciation command to add details about how the system's depreciation is computed. The following table shows the valid parameters for the command.
Table 55. Valid Parameters Of omconfig system assetinfo info=depreciation or omconfig servermodule assetinfo info=depreciation
Command
Level 1 omconfig
Command
Level 2 system or servermodule
Command
Level 3 assetinfo
Name= Value
Pair 1 info=depreciati on
Name= Value
Pair 2 duration=<n>
Description
Number of years or months over which a system is depreciated.
method=<text> Steps and assumptions used to compute the system's depreciation.
134
Command
Level 1
Command
Level 2
Command
Level 3
Name= Value
Pair 1
Name= Value
Pair 2 percent=<n>
Description unit=months | years
Portion of 100 that an asset is devalued or depreciated.
Unit is months or years.
Example command for adding depreciation information
To provide a value for a depreciation parameter, type a command of the form: omconfig system assetinfo info=depreciation <name=value pair 2> or omconfig servermodule assetinfo info=depreciation
<name=value pair 2>. For example, type: omconfig system assetinfo info=depreciation method=straightline or omconfig servermodule assetinfo info=depreciation method=straightline
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Commands For Adding Acquisition Information
.
Adding extended warranty information
Use the omconfig system extwarranty or omconfig servermodule extwarranty command to assign values for extended warranty information. A warranty is a contract between the manufacturer or dealer and the purchaser of a system. The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage. The extended warranty comes into force after the original warranty expires. For details on how to edit warranty values, see
.
The following table displays the valid parameters for the command
Table 56. Valid Parameters Of omconfig system assetinfo info=extwarranty Or omconfig servermodule assetinfo info=extwarranty
Command
Level 1 omconfig
Command
Level 2 system or servermodule
Command
Level 3
Name= Value
Pair 1 assetinfo info=extwarran ty
Name= Value Pair 2 Description cost=<cost> Cost of the extended warranty service.
enddate=<enddate> Date the extended warranty agreement ends.
provider=<provider
>
Business entity that provides the
135
Command
Level 1
Command
Level 2
Command
Level 3
Name= Value
Pair 1
Name= Value Pair 2 Description startdate=<startdate
> extended warranty service.
Date the extended warranty service begins.
Example command for adding extended warranty information
To provide a value for an extended warranty parameter, type a command of the form: omconfig system assetinfo info=extwarranty <name=value pair 2> or omconfig servermodule assetinfo info=extwarranty
<name=value pair 2>. For example, type: omconfig system assetinfo info=extwarranty enddate=012503 or omconfig servermodule assetinfo info=extwarranty enddate=012503
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Command For Adding Acquisition Information
.
Adding lease information
A lease is an agreement to pay for the use of a system for a specified period of time. The lessor retains ownership of the system. The following table displays the valid parameters for the command.
Table 57. Valid Parameters Of omconfig system assetinfo info=lease Or omconfig servermodule assetinfo info=lease
Command
Level 1 omconfig
Command
Level 2 system or servermodule
Command
Level 3 assetinfo
Name=
Value
Pair 1 info=leas e
Name= Value Pair 2 Description buyout=<amount> Amount of money paid to purchase a system from a lessor.
lessor=<lessor> Business entity that is leasing the system out.
multischedule=true
| false
Whether cost of leasing the system is computed by more than one rate schedule.
136
Command
Level 1
Command
Level 2
Command
Level 3
Name=
Value
Pair 1
Name= Value Pair 2 Description ratefactor=<factor> Factor used to calculate the lease payment.
value=<residual> Fair market value of the system at the end of the lease period.
Example command for adding lease information
To provide a value for a lease parameter, type a command of the form: omconfig system assetinfo info=lease <name=value pair 2> or omconfig servermodule assetinfo info=lease <name=value pair 2>.
For example, type: omconfig system assetinfo info=lease value=4500 or omconfig servermodule assetinfo info=lease value=4500
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfocommand at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1.
For an example, see Example Command For Adding Acquisition Information .
Adding maintenance information
Maintenance refers to activities required to keep the system in good working order. The following table displays the valid parameters for adding maintenance information.
Table 58. Valid Parameters Of omconfig system assetinfo info=maintenance Or omconfig servermodule assetinfo info=maintenance
Description Command
Level 1 omconfig
Command
Level 2 system or servermodule
Command
Level 3 assetinfo
Name= Value
Pair 1
Name= Value Pair
2 info=mainten ance enddate=<enddate
> provider=<provider
> startdate=<startdat
e>
Date the extended warranty agreement ends.
Business entity providing the maintenance service.
Date the maintenance begins.
137
Command
Level 1
Command
Level 2
Command
Level 3
Name= Value
Pair 1
Name= Value Pair
2 restrictions=<string
>
Description
Activities not covered by the maintenance contract.
Example command for adding maintenance information
To provide a value for a maintenance parameter, type a command of the form: omconfig system assetinfo info=maintenance <name=value pair 2> or omconfig system assetinfo info=maintenance
<name=value pair 2>.
For example, type: omconfig system assetinfo info=maintenance startdate=012504 or omconfig servermodule assetinfo info=maintenance startdate=012504
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Commands For Adding Acquisition Information
.
Adding outsource information
Outsourcing is the practice of contracting with another business to maintain the system in good working order. The following table displays the valid parameters for adding outsource information.
Table 59. Valid Parameters Of omconfig system assetinfo info=outsource Or omconfig servermodule assetinfo info=outsource
Description Comman d Level 1
Command
Level 2 omconfig system or servermodul e
Command
Level 3
Name=
Value Pair 1 assetinfo info=outsour ce
Name= Value Pair 2 levels=<n> problemcomponent=<comp
onent> providerfee=<providerfee> servicefee=<servicefee>
Levels of service that the provider offers.
System component that requires maintenance.
Amount of money charged for maintenance.
Amount of money charged for service.
138
Comman d Level 1
Command
Level 2
Command
Level 3
Name=
Value Pair 1
Name= Value Pair 2 signauth=<name>
Description
Person who signed or authorized the service.
Example command for adding outsource information
To provide a value for an outsource parameter, type a command of the form: omconfig system assetinfo info=outsource <name=value pair 2> or omconfig servermodule assetinfo info=outsource <name=value pair 2>. For example, type: omconfig system assetinfo info=outsource providerfee=75 or omconfig servermodule assetinfo info=outsource providerfee=75
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1.
For an example, see Example Command For Adding Acquisition Information .
Adding owner information
The owner is the party that holds legal property title to the system. The following table displays the valid parameters for adding owner information.
Table 60. Valid Parameters Of omconfig system assetinfo info=owner Or omconfig servermodule assetinfo info=owner
Name= Value Pair 2 Description Comman d Level 1
Command
Level 2 omconfig system or servermodul e
Comman d Level 3
Name=
Value Pair
1 assetinfo info=owne r insuranceco=<company> ownername=<business> type=owned | leased | rented
Name of the insurance company that insures the system.
Business entity that owns the system.
Whether the user of the system owns, leases, or rents the system.
139
Example command for adding owner information
To provide a value for an owner parameter, type a command of the form omconfig system assetinfo info=owner <name=value pair 2> or omconfig servermodule assetinfo info=owner <name=value pair 2>.
For example, type: omconfig system assetinfo info=owner type=rented or omconfig servermodule assetinfo info=owner type=rented
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Command For Adding Acquisition Information
.
Adding service contract information
A service contract is an agreement that specifies fees for preventive maintenance and repair of the system. The following table displays the valid parameters for adding contract information.
Table 61. Valid Parameters Of omconfig system assetinfo info=service Or omconfig servermodule assetinfo info=service
Comman d Level 1
Command
Level 2 omconfig system or servermodul e
Comman d Level 3
Name=
Value Pair 1
Name= Value Pair
2 assetinfo info=service renewed=true | false
Description
Whether the service agreement has been renewed.
type=<string> vendor=<business
>
Type of service that the contract covers.
Business entity that offers service on the system.
Example command for adding service information
To provide a value for a service parameter, type a command of the form omconfig system assetinfo info=service <name=value pair 2> or omconfig system assetinfo info=service <name=value pair 2>. For example, type: omconfig system assetinfo info=service vendor=fixsystemco or omconfig servermodule assetinfo info=service vendor=fixsystemco
The following message is displayed:
Asset information set successfully.
140
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Command For Adding Acquisition Information
.
Adding support information
Support refers to technical assistance that the system user can seek when the user seeks guidance on the proper use of a system to perform tasks. The following table displays the valid parameters for adding support information.
Table 62. Valid Parameters Of omconfig system assetinfo info=support Or omconfig servermodule assetinfo info=support
Description Comman d Level 1
Command
Level 2 omconfig system or servermodu le
Command
Level 3 assetinfo
Name=
Value Pair 1
Name= Value Pair 2 info=support automaticfix=<programna me> helpdesk=<text> outsourced=true | false type=network | storage
Name of any application used to fix a problem automatically.
The help desk name or contact information such as a phone number, email address, or website address.
Whether an external business entity provides technical support or the system owner's employees provide technical support.
Whether support is for network attached devices or for storage devices.
.
Example command for adding support information
To provide a value for a support parameter, type a command of the form omconfig system assetinfo info=support <name=value pair 2> or omconfig servermodule assetinfo info=support <name=value pair
2>. For example, type: omconfig system assetinfo info=support outsourced=true or omconfig servermodule assetinfo info=support outsourced=true
141
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Command For Adding Acquisition Information
.
Adding system information
System information includes the primary user of the system, the phone number for the primary user, and the location of the system. The following table displays the valid parameters for adding system information.
Table 63. Valid Parameters Of omconfig system assetinfo info=system Or omconfig servermodule assetinfo info=system
Name= Value Pair 2 Description Comman d Level 1
Command
Level 2 omconfig system or servermodu le
Comman d Level 3
Name=
Value Pair
1 assetinfo info=syste m location=<text> Location of the system.
primaryphone=<n> primaryuser=<user>
Phone number of the primary user of the system.
Primary user of the system.
Example command for adding system information
To provide a value for a system parameter, type a command of the form omconfig system assetinfo info=system <name=value pair 2> or omconfig servermodule assetinfo info=system <name=value pair
2>. For example, type: omconfig system assetinfo info=system location=firstfloor or omconfig servermodule assetinfo info=system location=firstfloor
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Command For Adding Acquisition Information
.
Adding warranty information
Use the omconfig system warranty or omconfig servermodule warranty command to assign values for warranty information. A warranty is a contract between the manufacturer or dealer and the purchaser of a system. The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage. For details on editing extended warranty values, see
142
Table 64. Valid Parameters Of omconfig system assetinfo info=warranty Or omconfig servermodule assetinfo info=warranty
Description Command
Level 1
Command
Level 2 omconfig system or servermodul e
Command
Level 3 assetinfo
Name=
Value Pair 1 info=warrant y
Name= Value Pair 2 cost=<cost> Cost of the warranty service.
duration=<duration> enddate=<enddate> unit=days | months
Number of days or months that the warranty is in force.
Date the warranty agreement ends.
Whether the number for duration refers to days or months.
Example command for adding warranty information
To provide a value for a warranty parameter, type a command of the form omconfig system assetinfo info=warranty <name=value pair 2> or omconfig servermodule assetinfo info=warranty <name=value pair 2>. For example, type: omconfig system assetinfo info=warranty unit=days or omconfig servermodule assetinfo info=warranty unit=days
The following message is displayed:
Asset information set successfully.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see
Example Command For Adding Acquisition Information
.
143
Using The Storage Management Service
6
The CLI of Storage Management enables you to perform reporting, configuration, and management functions of Storage Management from an operating system command shell. The Storage Management
CLI also enables you to script command sequences.
The Storage Management CLI provides expanded options for the Dell OpenManage Server Administrator omreport and omconfig commands.
NOTE: For more information, see the Dell Server Administrator Installation Guide and Dell
Management Station Software Installation Guide available at dell.com/openmanagemanuals. For more information on Storage Management, see the Storage Management online Help or the Dell
Server Administrator Storage Management User’s Guide available at dell.com/openmanagemanuals.
CLI command syntax
Like all Server Administrator commands, the omreport and omconfig command syntax consists of specifying command levels. The first command level is the command name: omreport or omconfig.
Subsequent command levels provide a greater degree of specification regarding the type of object on which the command operates or the information that the command displays.
For example, the following omconfig command syntax has three levels: omconfig storage pdisk
The following table describes these command levels.
Table 65. Example Command Levels
Command level 1 omconfig
Command level 2 Command level 3 storage pdisk
Use
Specifies the command
Indicates the Server
Administrator service (in this case, Storage
Management) that implements the command
Specifies the type of object on which the command operates
144
Following the command levels, the omreport and omconfig command syntax may require one or more name=value pairs. The name=value pairs specify exact objects (such as a specific physical disk) or options
(such as blink or unblink) that the command implements.
For example, the following omconfig command syntax for blinking a physical disk has three levels and three name=value pairs: omconfig storage pdisk action=blink controller=id pdisk=<PDISKID> where PDISKID=<onnector:enclosureID:targetID | connector:targetID>
In this example, the id in controller=idis the controller number such that controller 1 is specified as controller=1.
Syntax Of Command Elements
The omreport and omconfig commands have multiple name=value pairs. These name=value pairs may include required, optional, and variable parameters. The following table describes the syntax used to indicate these parameters.
Table 66. Syntax For Name=Value Pairs
Syntax controller=id
Description
Indicates the controller ID as reported by the omreport storage controller command. To obtain these values, type omreport storage controller to display the controller
IDs and then type omreport storage pdisk controller=id to display the IDs for the physical disks attached to the controller.
For example, the controller=id parameter is specified as controller=1.
connector=id vdisk=id enclosure=<ENCLOSUREID>
Indicates the connector ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage connector controller=id to display the IDs for the connectors attached to the controller.
For example, the connector=id parameter is specified as connector=2.
Indicates the virtual disk ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=id to display the
IDs for the virtual disks on the controller.
For example, the vdisk=id parameter is specified as vdisk=3.
Indicates a particular enclosure by specifying either enclosure=connector or enclosure=connector:enclosureID.
To obtain these values, type omreport storage controller to display the controller IDs and then type
145
|
Syntax pdisk=<PDISKID> battery=id
< >
[ ]
Description omreport storage enclosure controller=id to display the IDs for the enclosures attached to the controller.
Indicates a particular physical disk by specifying either connector:targetID or connector:enclosureID:targetID.
To obtain the values for the connector, enclosure, and physical disk (targetID), type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=id to display the
IDs for the physical disks attached to the controller.
Indicates the battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=id to display the ID for the controller battery.
The caret symbols (< >) enclose variable elements that you must specify.
For example, the name=<string>parameter is specified as name=VirtualDisk1.
The bracket symbols ([ ]) indicate optional elements that you can choose whether or not to specify.
For example, when creating a virtual disk, the [name=<string>] parameter indicates that you have the option of specifying the virtual disk name. If you omit this parameter from the syntax, then a default name for the virtual disk is chosen for you.
The pipe symbol (|) separates two or more options from which only one is selected.
For example, when creating a virtual disk, the cachepolicy=d | c indicates that the cache policy is specified as either cachepolicy=d or cachepolicy=c.
User Privileges For Omreport Storage And Omconfig
Storage
Storage Management requires Administrator privileges to use the omconfig storage command. User and
Power User privileges are sufficient to use the omreport storage command.
146
7
Omreport storage commands
The omreport command allows you to view storage component information for disks, controllers, enclosures, batteries, global storage properties, connectors and cachecades that are part of the storage system. The omreport command helps to get reports with the level of detail that you want.
The commands may vary in, whether they define the fields that appear in the results of a particular omreport command. Fields are defined only if they have a special or less familiar use.
The following sections provide the omreport command syntax required to display the information of various storage components.
To see a list of valid commands for omreport storage, type: omreport storage -?
The following table provides the omreport storage command syntax.
Table 67. Omreport Storage Help
Command
Level 1 omreport
Command
Level 2 storage
Command
Level 3
Use pdisk vdisk controller enclosure battery globalinfo connector cachecade
Displays a list of storage components for which omreport commands are available.
Displays a list of the omreport storage pdisk parameters for displaying physical disk information.
Displays a list of omreport storage vdisk parameters for displaying virtual disk information.
Displays a list of the omreport storage controller parameters for displaying controller information.
Displays a list of the omreport storage enclosure parameters for displaying enclosure information.
Displays a list of the omreport storage battery parameters for displaying battery information.
Displays a list of the omreport storage globalinfo parameters for displaying global storage property information.
Displays a list of the omreport storage connector parameters for displaying connector information.
Displays a list of the omreport storage cachecade parameters for displaying cachecade properties.
147
Command
Level 1
Command
Level 2
Command
Level 3 pciessed
Use
Displays the properties of the PCIe SSD subsystem.
nvmeadapter Displays the list of NVMe adapters.
Omreport Physical Disk Status
The following table describes the syntax for the omreport Physical Disk commands.
Table 68. Omreport Physical Disk Commands
Use Required Command Levels (1, 2,
3) And name=value pair omreport storage pdisk
Optional name=value pairs controller=id, where id is the controller number. For example, controller=0
Displays all physical disks attached to the specified controller.
NOTE: If a physical disk was replaced by another disk as part of the replace member operation, the state of the physical disk is displayed as
Replacing.
vdisk=id, where id is the virtual disk number. For example, vdisk=1
Displays all physical disks included in the specified virtual disk on the controller.
cachecade=id where id is the cachecade number. For example, cachecade=1
Displays all physical disks included in the specified cachecade on the controller.
connector=id where id is the connector number. For example, connector=1
Displays all physical disks attached to the specified connector on the controller.
pdisk=connectorID : targetID | connectorID : enclosureID : slotID, where
connectorID:targetID is the connector number and the physical disk number and connectorID:enclosureID:slotID is the connector number, enclosure number, and slot number. For example, pdisk=0:2 or pdisk=0:1:2
Displays the specified physical disk on the specified connector on the controller.
148
omreport Virtual Disk Status
The following table describes the syntax for the omreport Virtual Disk commands:
Table 69. omreport Virtual Disk Commands
Required Command Levels (1, 2,
3) omreport storage vdisk
Optional name=value pairs Use controller=id, where id is the controller number. For example, controller=0.
controller=id vdisk=id, where id is the controller number and the virtual disk number. For example, controller=0 vdisk=1.
Displays property information for all virtual disks on all controllers.
Displays all virtual disks on the specified controller.
Displays the specified virtual disk on the controller.
Omreport controller status
The following table describes the syntax for the omreport Controller commands.
Table 70. Omreport controller commands
Required command levels (1, 2, 3) omreport storage controller
Optional name=value pairs Use controller=id, where id is the controller number. For example, controller=0 controller=id info=foreignkeyids controller=id info=pdslotreport
Displays property information for all controllers attached to the system.
Displays the specified controller and all attached components such as enclosures, virtual disks, physical disks, HHHL cards, and so on.
Displays the locked foreign configuration information for import or clear operations.
Displays the empty and occupied slot details of enclosures in the controller.
NOTE: This command is not supported on
Blackplane, SCSI, and SWRAID controllers.
Omreport Enclosure Status
The following sections provide the omreport storage enclosure command syntax required to execute the enclosure commands. The following table describes the syntax for the omreport Enclosure commands.
149
Table 71. Omreport Enclosure Commands
Required Command
Levels (1, 2, 3)
Optional name=value pairs omreport storage enclosure
Use
Displays property information for all enclosures attached to the system.
controller=id, where id is the controller number
Displays all enclosures connected to the controller.
controller=id enclosure=<ENCLOSUREID>, where id is the controller number and
<ENCLOSUREID>is the enclosure ID.
Example for SCSI controllers: controller=0 enclosure=2. Example for
SAS controllers: controller=0 enclosure=1:2.
Displays the specified enclosure and its components.
Omreport Temperature Probe Status
The following table describes the syntax for the omreport Probe commands
Table 72. Omreport Temperature Probe Commands
Required Command Levels (1, 2,
3) and name=value pair
Optional name=value pairs omreport storage enclosure
Use
Displays property information for all enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> info=temps where id is the controller number and
<ENCLOSUREID> is the enclosure
ID. Example for SCSI controllers: controller=0 enclosure=2 info=temps. Example for SAS controllers: controller=0 enclosure=1:2 info=temps
Displays the temperature probes for the specified enclosure.
controller=id enclosure=<ENCLOSUREID> info=temps index=n where id is the controller number and
<ENCLOSUREID> is the enclosure number and n is the number of a temperature probe. For example: controller=0 enclosure=2 info=temps index=1
Displays the temperature probes for the specified enclosure.
150
Omreport Fan Status
The following table describes the syntax for the omreport Fan commands
Table 73. Omreport Fan Status
Required Command Levels (1, 2,
3) and name=value pair
Optional name=value pairs Use omreport storage enclosure Displays property information for all enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> info=fans where id is the controller number and
ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2
NOTE: For SCSI controllers, the ID specified in enclosure=<ENCLOSUREID> is the connector number and for Serial Attached SCSI (SAS) controllers, ID is the connectorNumber:Enclosur eIndex.
Displays the fans for the specified enclosure.
controller=id enclosure=<ENCLOSUREID> info=fans index=n where id is the controller number and
ENCLOSUREID is the enclosure number and n is the number of a fan. For example: controller=0 enclosure=2 info=fans index=1
Displays the specified fan.
Omreport Power Supply Status
The following table describes the syntax for the omreport Power Supply commands
Table 74. Omreport Power Supply Commands
Required Command Levels (1, 2,
3) and name=value pair
Optional name=value pairs Use omreport storage enclosure Displays property information for all enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> info=pwrsupplies where id is the controller number and
ENCLOSUREID is the enclosure
Displays the power supplies for the specified enclosure.
151
Required Command Levels (1, 2,
3) and name=value pair
Optional name=value pairs number. For example: controller=0 enclosure=2
Use controller=id enclosure=<ENCLOSUREID> info=pwrsupplies index=n where id is the controller number and
ENCLOSUREID is the enclosure number and n is the number of a power supply. For example: controller=0 enclosure=2 info=pwrsupplies index=1
Displays the specified power supply.
Omreport EMM Status
The following table describes the syntax for the omreport EMM commands
NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.
Table 75. Omreport EMM Commands
Required Command Levels (1, 2,
3) and name=value pair omreport storage enclosure
Optional name=value pairs Use
Displays property information for all enclosures attached to the system.
Displays the enclosure management modules (EMMs) for the specified enclosure.
controller=id enclosure=<ENCLOSUREID> info=emms where id is the controller number and
ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2 controller=id enclosure=<ENCLOSUREID> info=emms index=n where id is the controller number and
ENCLOSUREID is the enclosure number and n is the number of an EMM. For example: controller=0 enclosure=2 info=emms index=1
Displays the specified EMMs.
Omreport Enclosure Slot Occupancy Report
The following table describes the syntax for the omreport Enclosure Slot Occupancy Report commands
152
Table 76. Omreport Enclosure Slot Occupancy Report Commands
Required Command Levels (1, 2,
3) and name=value pair omreport storage enclosure
Optional name=value pairs Use
Displays property information for all enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> info=pdslotreport, where id is the controller number and
ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2
Displays the empty and occupied slot details for the specified enclosure.
NOTE: This command is not supported on Blackplane,
SCSI, and SWRAID controllers.
Omreport Battery Status
The following table describes the syntax for the omreport Battery commands
Table 77. Omreport Battery Commands
Use Required Command Levels (1, 2,
3) omreport storage battery
Optional name=value pairs
Displays all batteries present on all controllers on the system
(Some controllers do not have batteries).
Displays the battery on the specified controller.
controller=id, where id is the controller number. For example: controller=0 controller=id battery=id, where id is the controller number. For example: controller=0
Displays the specified battery.
Omreport Global Information
The following table describes the syntax for the omreport Global Information commands.
Table 78. Omreport Global Information Commands
Optional name=value pairs Use Required Command Levels (1,
2, 3) omreport storage globalinfo Displays whether smart thermal shutdown is enabled or disabled.
For more information, see
.
153
Required Command Levels (1,
2, 3)
Optional name=value pairs Use
Displays the hot spare protection policy that you have set. For more information on setting hot spare protection policy, see the Dell
OpenManage Server Administrator
Storage Management User’s Guide at dell.com/support/manuals.
Omreport Connector Status
The following table describes the syntax for the omreport Connector commands
Table 79. Omreport Connector Commands
Required Command Levels (1, 2,
3)
Optional name=value pairs Use omreport storage connector Displays all connectors present on all controllers on the system.
NOTE: This command works only when the controller ID is specified.
controller=id, where id is the controller number. For example: controller=0
Displays the connectors on the specified controller.
controller=id connector=id, where id is the connector number. For example, connector=0
Displays the specified connector.
NOTE: When the connectors are connected to the enclosure in redundant path mode, the Name of the connector is displayed as
Logical Connector.
Omreport Cachecade Status
The following table describes the syntax for the omreport Cachecade commands
Table 80. Omreport Cachecade Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs Use omreport storage cachecade
Displays property information for all cachecades on all controllers.
controller=id, where id is the controller number. For example, controller=0.
controller=id cachecade=id, where id is the controller number and the
Displays all cachecades on the specified controller.
Displays the specified cachecade on the controller.
154
Required Command Levels
(1, 2, 3)
Optional name=value pairs cachecade number. For example, controller=0 cachecade=1.
Use
Omreport PCIe SSD Status
The following table describes the syntax for the omreport pciessd commands.
Table 81. omreport PCIe SSD Command
Use Required Command Levels (1, 2,
3) And name=value pair omreport storage pciessd
Optional name=value pairs
Displays the properties of the
PCIe SSD subsystem.
subsystem=id Displays the properties of the specified PCIe subsystem.
Omreport Storage Tape
The following table describes the syntax for the omreport storage tape command.
Table 82. Omreport Storage Tape Commands
Use Required Command Levels
(1, 2, 3)
Optional name=value pairs omreport storage tape controller=id, where id is the controller number. For example: controller=0.
connector=id
Display tape drive properties.
Displays all tape drives.
tape=<tape id>, where tapeid=id=<connector:targetID>
Displays all the tape drives on the specified connector.
Displays the specified tape drive.
Omreport NVMe adapter
The following table describes the syntax for the omreport nvmeadapter commands.
155
Table 83. omreport NVMe adapter command
Required Command Levels (1, 2,
3) And name=value pair omreport storage nvmeadapter
Optional name=value pairs Use
Displays the properties of the
NVMe adapters.
controller=id, where id is the controller number. For example, controller=0.
Displays the properties of all the
NVMe adapters on the specified controller.
controller=id, nvmeid=id, where id is the controller number and the NVMe adapter respectively.
For example, controller=0 nvmeid=1.
Displays the properties of the specified NVMe adapter on the specified controller.
156
Omconfig storage commands
The omconfig commands allows you to configure physical disks, virtual disks, controllers, enclosures, batteries, global information, connectors, and cachecades.
To see a list of valid commands for omconfig storage, type: omconfig storage -?
The following table provides the omconfig storage command syntax:
Table 84. Omconfig Storage Help
Command
Level 1 omconfig
Command
Level 2
Command
Level 3
Use storage pdisk vdisk controller enclosure battery globalinfo connector
Sets the storage component properties for which omconfig commands are available.
Displays the list of omconfig storage pdisk parameters for configuring physical disks.
Displays the list of omconfig storage vdisk parameters for configuring virtual disks.
Displays a list of the omconfig storage controller parameters for configuring controllers.
Displays a list of the omconfig storage controller parameters for configuring enclosures.
Displays a list of the omconfig storage battery parameters for configuring batteries.
Displays a list of the omconfig storage globalinfo parameters for configuring global storage properties.
Displays a list of the omreport storage connector parameters for configuring connectors.
cachecade Displays a list of the omconfig storage cachecade parameters for configuring cachecades.
nvmeadapter Displays a list of the omconfig storage nvmeadapter parameters for configuring the NVMe adapters.
8
157
Omconfig Physical Disk Commands
The following sections provide the omconfig command syntax required to execute physical disk tasks
Table 85. Omconfig Physical Disk Commands
Optional name=value pairs Required Command Levels (1,
2, 3) omconfig storage pdisk action=blink controller=id pdisk=<PDISKID> action=unblink controller=id pdisk=<PDISKID> action=remove controller=id pdisk=<PDISKID> action=instantsecureerase controller=id pdisk=<PDISKID> action=cryptographicerase controller=id pdisk=<PDISKID> action=initialize controller=id pdisk=<PDISKID> action=offline controller=id pdisk=<PDISKID> action=online controller=id pdisk=<PDISKID> action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=<yes | no> action=rebuild controller=id pdisk=<PDISKID> action=cancelrebuild controller=id pdisk=<PDISKID> action=cancelreplacemember controller=id pdisk=<PDISKID> action=clear controller=id pdisk=<PDISKID> action=cancelclear controller=id pdisk=<PDISKID> action=enabledevicewritecache controller=id pdisk=<PDISKID> action=disabledevicewritecache controller=id pdisk=<PDISKID> action=exportlog controller=id pdisk=<PDISKID>
[filename=<filename>], the filename mentioned here is optional.
action=convertraidtononraid controller=id pdisk=<PDISKID> action=convertnonraidtoraid controller=id pdisk=<PDISKID> action=setarraydiskcache controller=id pdisk=<PDISKID>
Omconfig Blink Physical Disk
Description
Syntax
Blinks the light (light emitting diode or LED display) on one or more physical disks attached to a controller.
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>, where id is
158
Example to
Example for SCSI, SATA, and ATA controllers
Example for SAS controllers the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Blink physical disk 0 on connector 0 of controller
1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=blink controller=1 pdisk=0:0 omconfig storage pdisk action=blink controller=1 pdisk=0:2:0
Omconfig Unblink Physical Disk
Description
Syntax
Example to
Example for SCSI, SATA, and ATA controllers
Example for SAS controllers
Unblinks the light (light emitting diode or LED display) on one or more physical disks attached to a controller.
omconfig storage pdisk action=unblink controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Unblink physical disk 0 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=unblink controller=1 pdisk=0:0 omconfig storage pdisk action=unblink controller=1 pdisk=0:2:0
159
Omconfig Prepare To Remove Physical Disk
Table 86. Omconfig Prepare To Remove Physical Disk
Description Prepares a physical disk for removal.
Syntax omconfig storage pdisk action=remove controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example to
Example for SCSI, SATA, and ATA controllers
Prepares physical disk 3 on connector 0 of controller 1 for removal. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=remove controller=1 pdisk=0:3
Example for SAS controllers omconfig storage pdisk action=remove controller=1 pdisk=0:2:3
Omconfig Instant Erase Secured Physical Disk
Description Erases the given encrypted disk.
NOTE: This command is applicable only on
Micron devices.
Syntax
Example to
Example for SCSI, SATA, and ATA controllers omconfig storage pdisk action=instantsecureerase controller=id pdisk=<PDISKID>, where id is the controller ID.
The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Erase physical disk 3 on connector 0 of controller
1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=instantsecureerase controller=1 pdisk=0:3
160
Example for SAS controllers omconfig storage pdisk action=instantsecureerase controller=1 pdisk=0:2:3
Omconfig Cryptographic Erase Secured Physical Disk
Description Erases the given encrypted disk.
NOTE: This command is applicable only on
Non-Volatile Memory Express (NVMe) devices.
Syntax
Example to
Example for SCSI, SATA, and ATA controllers omconfig storage pdisk action=cryptographicerase controller=id pdisk=<PDISKID>, where id is the controller ID.
The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Erase physical disk 3 on connector 0 of controller
1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=cryptographicerase controller=1 pdisk=0:3
Example for SAS controllers omconfig storage pdisk action=cryptographicerase controller=1 pdisk=0:2:3
Omconfig Initialize Physical Disk
Description
Syntax
Example to
Initializes a physical disk.
omconfig storage pdisk action=initialize controller=id pdisk=id, where id is the controller ID and physical disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Initialize physical disk 4 on controller 1
161
Example omconfig storage pdisk action=initialize controller=1 pdisk=4
Omconfig Offline Physical Disk
Description
Syntax
Example to
Example for SCSI, SATA, and ATA controllers
Example for SAS controllers
Makes a physical disk offline.
omconfig storage pdisk action=offline controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Offline physical disk 3 on connector 0 of controller
1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=offline controller=1 pdisk=0:3 omconfig storage pdisk action=offline controller=1 pdisk=0:2:3
Omconfig Online Physical Disk
Description
Syntax
Example to
Example for SCSI, SATA, and ATA controllers
Example for SAS controllers
Brings an offline physical disk back online.
omconfig storage pdisk action=online controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Bring physical disk 3 on connector 0 of controller 1 back online. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=online controller=1 pdisk=0:3 omconfig storage pdisk action=online controller=1 pdisk=0:2:30
162
Omconfig Assign Global Hot Spare
Description
Syntax
Example to
Example for SCSI, SATA, and ATA controllers
Example for SAS controllers
Assigns a physical disk as a global hot spare.
omconfig storage pdisk action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=yes, where id is the controller ID. The
<PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Assign physical disk 3 on connector 0 of controller
1 as a global hot spare. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:3 assign=yes omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:2:3 assign=yes
Omconfig Rebuild Physical Disk
Description
Syntax
Example to
Example for SCSI, SATA, and ATA controllers
Rebuilds a failed physical disk. Rebuilding a disk may take several hours. If you need to cancel the rebuild, use the Cancel Rebuild task. For more information about Rebuild Physical Disk, see the
Dell OpenManage Online Help .
omconfig storage pdisk action=rebuild controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Rebuild physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=rebuild controller=1 pdisk=0:3
163
Example for SAS controllers omconfig storage pdisk action=rebuild controller=1 pdisk=0:2:3
Omconfig Cancel Rebuild Physical Disk
Description
Syntax
Cancels a rebuild that is in progress. If you cancel a rebuild, the virtual disk remains in a degraded state.
For more information about Cancel Rebuild
Physical Disk, see the Dell OpenManage Online
Help .
omconfig storage pdisk action=cancelrebuild controller=id pdisk=<PDISKID>, where id is the controller ID.
The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example to Cancel the rebuild of physical disk 3 on connector
0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
Example for SAS controllers omconfig storage pdisk action=cancelrebuild controller=1 pdisk=0:3 omconfig storage pdisk action=cancelrebuild controller=1 pdisk=0:2:3
Omconfig Cancel Replace Member
Description
Syntax
Example to
Cancels a replace member operation.
omconfig storage pdisk action=cancelreplacemember controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Cancel replace member operation on disk 0:0:1 which is connected to controller 0
164
Example omconfig storage pdisk action=cancelreplacemember controller=0 pdisk=0:0:1
Omconfig Clear Physical Disk
Description
Syntax
Example to
Example for SAS controllers
Clears data or a configuration from a physical disk.
omconfig storage pdisk action=clear controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Clear physical disk 3 on connector 0 of controller
1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=clear controller=1 pdisk=0:2:3
Omconfig cancel clear physical disk
Description
Syntax
Example to
Example for SCSI, SATA, and ATA controllers
Cancels a clear operation in progress on a physical disk.
omconfig storage pdisk action=cancelclear controller=id pdisk=<PDISKID>, where id is the controller ID.
The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Cancel the clear of physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=cancelclear controller=1 pdisk=0:2:3
165
Omconfig Enable Device Write Cache
Description
Syntax
Enables write cache on a physical disk for the PCIe
SSD controller.
omconfig storage pdisk action=enabledevicewritecache controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example to
Example for SAS controllers
Enable write cache on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=enabledevicewritecache controller=1 pdisk=0:2:3
Omconfig Disable Device Write Cache
Description
Syntax
Disables write cache on a physical disk for the PCIe
SSD controller.
omconfig storage pdisk action=disabledevicewritecache controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example to
Example for SAS controllers
Disable write cache on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=disabledevicewritecache controller=1 pdisk=0:2:3
166
Omconfig Export Reliability Log
Description
Syntax
Example to
Example for SAS controllers
Exports log on a physical disk or the NVMe adapter.
The reliability log for the device PCIe SSD device or
NVMe device is exported to the Windows folder on systems running Windows, and to /var/log directory on systems running Linux.
omconfig storage pdisk action=exportlog controller=id pdisk=<PDISKID> filename=<filename>, where id is the controller
ID . The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
NOTE: The <filename> is optional. If
<filename> is not present, a default filename is assigned.
NOTE: Depending on the PCIe SSD or NVMe device the log file name will be
PCIeSSD_<device name>_<timestamp>.log or
NVMe_<device name>_<timestamp>.log where the <device name> is the name of the device and timestamp is month, day, hour, minute and second during which the command is executed.
Export log on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=exportlog controller=1 pdisk=0:2:3
Omconfig Convert RAID To Non-RAID
Description Converts RAID to non-RAID on a physical disk.
Syntax omconfig storage pdisk action=convertraidtononraid controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
167
Example to
Example for SAS controllers
NOTE: To convert multiple RAID to non-RAID on a given controller, use omconfig storage controller action=convertraidtononraid command. For more information, see
omconfig Convert Multiple RAID To Non-
.
Convert RAID to non-RAID on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=raidtononraid controller=1 pdisk=0:2:3
Omconfig Convert Non-RAID To RAID
Description Converts non-RAID to RAID on a physical disk.
Syntax omconfig storage pdisk action=convertnonraidtoraid controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
NOTE: To convert multiple non-RAID to RAID on a given controller, use omconfig storage controller action=convertnonraidtoraid command. For more information, see
omconfig Convert Multiple Non-RAID To
.
Example to Convert non-RAID to RAID on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SAS controllers omconfig storage pdisk action=nonraidtoraid controller=1 pdisk=0:2:3
Omconfig Set array disk cache
Description Setting the disk cache policy on the given physical disk.
Syntax omconfig storage pdisk action=setarraydiskcache controller=id pdisk=<PDISKID>, where PDISKID=<connector:enclosureID:portID | connector:targetID>.
168
Example to
Example
Set the disk cache policy on the physical disk.
omconfig storage pdisk action=setarraydiskcache controller=0 pdisk=0:2:3
Omconfig virtual disk commands
The following table provides the omconfig command syntax required to execute virtual disk tasks.
CAUTION: The omconfig storage vdisk action=deletevdisk controller=id vdisk=id command deletes a virtual disk. Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk.
Table 87. Omconfig Manage Virtual Disk Commands
Required Command
Levels (1, 2, 3)
Optional name=value pairs omconfig storage vdisk action=checkconsistency controller=id vdisk=id action=cancelcheckconsistency controller=id vdisk=id action=pausecheckconsistency controller=id vdisk=id action=resumecheckconsistency controller=id vdisk=id action=checkconsistency controller=id vdisk=id action=blink controller=id vdisk=id action=unblink controller=id vdisk=id action=initialize controller=id vdisk=id action=fastinit controller=id vdisk=id [force=yes] action=slowinit controller=id vdisk=id [force=yes] action=cancelinitialize controller=id vdisk=id action=cancelbginitialize controller=id vdisk=id action=assigndedicatedhotspare controller=id vdisk=id pdisk=<PDISKID> assign=<yes | no> action=deletevdisk controller=id vdisk=id [force=yes] action=reconfigure controller=id vdisk=id raid=<c | r0 | r1 | r1c | r5 | r10> pdisk=<PDISKID> [size=<size> vdcapacityexpansion=yes sizeinpercent=<1 to
100>] action=securevd controller=id vdisk=id action=clearvdbadblocks controller=id vdisk=id ction=changepolicy controller=id vdisk=id [readpolicy=<ra | nra | ara | rc | nrc> | writepolicy=<wb | wt | wc | nwc | fwb> | cachepolicy=<d | c> diskcachepolicy=<enabled | disabled>]
169
Required Command
Levels (1, 2, 3)
Optional name=value pairs action=replacememberdisk controller=id vdisk=id source=<PDISKID> destination=<PDISKID> action=rename controller=id vdisk=id action=enablefluidcache controller=id vdisk=id devicename=<string> cachepolicy=<wb | wt> action=disablefluidcache controller=id vdisk=id devicename=<string> action=reactivate controller=id vdisk=id devicename=<string>
Omconfig Check Consistency
Description
Syntax
Initiates a check consistency on a virtual disk. The check consistency task verifies the virtual disk’s redundant data.
omconfig storage vdisk action=checkconsistency controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to
Example
Run a check consistency on virtual disk 4 on controller 1.
omconfig storage vdisk action=checkconsistency controller=1 vdisk=4
Omconfig cancel check consistency
Description Cancels a check consistency while in progress.
Syntax omconfig storage vdisk action=cancelcheckconsistency controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to Cancel a check consistency on virtual disk 4 on controller 1.
Example omconfig storage vdisk action=cancelcheckconsistency controller=1 vdisk=4
170
Omconfig Pause Check Consistency
Description
Syntax
Pauses a check consistency while in progress. For more information, see the Dell OpenManage Online Help.
omconfig storage vdisk action=pausecheckconsistency controller=id vdisk=id , where id is the controller ID and virtual disk
ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to
Example
Pause a check consistency on virtual disk 4 on controller 1 omconfig storage vdisk action=pausecheckconsistency controller=1 vdisk=4
Omconfig Resume Check Consistency
Description Resumes a check consistency after it has been paused.
Syntax omconfig storage vdisk action=resumecheckconsistency controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to Resume a check consistency on virtual disk 4 on controller 1.
Example omconfig storage vdisk action=resumecheckconsistency controller=1 vdisk=4
Omconfig blink virtual disk
Description Blinks the physical disks included in a virtual disk.
Syntax omconfig storage vdisk action=blink controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to
Example
Blink the physical disks in virtual disk 4 on controller 1.
omconfig storage vdisk action=blink controller=1 vdisk=4
171
Omconfig Unblink Virtual Disk
Description Unblinks the physical disks included in a virtual disk.
Syntax omconfig storage vdisk action=unblink controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example to Unblink the physical disks in virtual disk 4 on controller 1.
Example omconfig storage vdisk action=unblink controller=1 vdisk=4
Omconfig Initialize Virtual Disk
Description Initializes a virtual disk.
Syntax omconfig storage vdisk action=initialize controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to
Example
Initialize virtual disk 4 on controller 1 omconfig storage vdisk action=initialize controller=1 vdisk=4
Omconfig Fast Initialize Virtual Disk
Description Fast initializes a virtual disk.
CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.
Syntax omconfig storage vdisk action=fastinit controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
172
Example to
Example
NOTE: In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage vdisk action=fastinit controller=id vdisk=id force=yes
Fast initialize virtual disk 4 on controller 1.
omconfig storage vdisk action=fastinit controller=1 vdisk=4
Omconfig Slow Initialize Virtualize Disk
Description Slow initializes a virtual disk.
CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.
Syntax
Example to omconfig storage vdisk action=slowinit controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
NOTE: In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage vdisk action=slowinit controller=id vdisk=id force=yes
Slow initialize virtual disk 4 on controller 1.
Example omconfig storage vdisk action=slowinit controller=1 vdisk=4
Omconfig cancel initialize virtual disk
Description Cancels the initialization of a virtual disk.
Syntax
Example to omconfig storage vdisk action=cancelinitialize controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Cancels the initialization of virtual disk 4 on controller 1.
173
Example omconfig storage vdisk action=cancelinitialize controller=id vdisk=id
Omconfig cancel background initialize
Description Cancels the background initialization process on a virtual disk.
Syntax
Example to
Example omconfig storage vdisk action=cancelbginitialize controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Cancel background initialization on virtual disk 4 on controller 1.
omconfig storage vdisk action=cancelbginitialize controller=1 vdisk=4
Omconfig Assign Dedicated Hot Spare
Description Assigns one or more physical disks to a virtual disk as a dedicated hot spare.
Syntax
Example to omconfig storage vdisk action=assigndedicatedhotspare controller=id vdisk=id pdisk=<PDISKID> assign=yes, where id is the controller ID and virtual disk ID as reported by the omreport command. The
<PDISK>variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks and physical disks attached to the controller.
Assign physical disk 3 on connector 0 of controller 1 as a dedicated hot spare to virtual disk 4. On a Serial Attached SCSI (SAS) controller, the physical disk resides in enclosure 2.
Example for SCSI,
SATA, and ATA controllers
Example for SAS controllers omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:3 assign=yes omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:2:3 assign=yes
Omconfig Delete Virtual Disk
Description Deletes a virtual disk.
174
Syntax
Example to
Example
CAUTION: Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk. You may receive a warning message if you attempt to delete the system or boot partition.
However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.
omconfig storage vdisk action=deletevdisk controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
NOTE: In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage vdisk action=deletevdisk controller=id vdisk=id force=yes
Delete virtual disk 4 on controller 1 omconfig storage vdisk action=deletevdisk controller=1 vdisk=4
Omconfig reconfiguring virtual disks
Description Reconfigure a virtual disk to change the virtual disk’s RAID level or increase its size by either adding physical disks or using the available free space. On some controllers, you can also remove physical disks.
NOTE: If you want to reconfigure with an extra physical disk, the physical disk must be of the supported bus protocol, media type, sector size, T10
Protection Information capability, and encryption capability.
Syntax omconfig storage vdisk action=reconfigure controller=id vdisk=id raid=<c| r0| r1| r1c| r5| r6| r10> pdisk=<PDISK>
[size=<size> vdcapacityexpansion=yes sizeinpercent=<1 to
100>], where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: When you perform the virtual disk reconfiguration operation using the sizeinpercent/vdcapacityexpansion argument, Storage
Management does not allow addition of physical disks to the existing reconfigured disk group. On successful operation, the virtual disk capacity is expanded, but the additional physical disk is not considered.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example to Reconfigure virtual disk 4 to a size of 800 MB, use RAID-5 and physical disks 0 through 3 on connector 0 of controller 1. On a SAS controller, the physical disks reside in enclosure 2.
175
Example for SCSI,
SATA, and ATA controllers
Example for SAS controllers
Example to
Example omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 size=800m pdisk=0:0:0,0:1:1,0:2:0,0:3:2 omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 pdisk=0:2:0,0:2:1,0:2:2,0:2:3
Increase the size of the virtual disk by 20 percent using the available free space, use RAID-5 and physical disks 0 through 3 on connector 0 of controller 1. On a
SAS controller, the physical disks reside in enclosure 2.
omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 pdisk=0:2:0,0:2:1,0:2:2,0:2:3 vdcapacityexpansion=yes sizeinpercent=20
NOTE: The vdcapacityexpansion parameter is supported only on PERC
H700 and PERC H800 controllers. If you set vdcapacityexpansion=yes, specify sizeinpercent. If you do not set vdcapacityexpansion, specify size.
NOTE: The sizeinpercent parameter is not supported on PERC S130 controller.
Omconfig Secure Virtual Disk
Description Encrypts a virtual disk.
Syntax
Example to omconfig storage vdisk action=securevd controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Encrypt virtual disk 4 on controller 1.
Example omconfig storage vdisk action=securevd controller=1 vdisk=4
Omconfig Clear Virtual Disk Bad Blocks
Description Clears virtual disk bad blocks.
Syntax
Example to omconfig storage vdisk action=clearvdbadblocks controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Clear bad blocks on virtual disk 4 on controller 1.
176
Example omconfig storage vdisk action=clearvdbadblocks controller=1 vdisk=4
Omconfig Change Virtual Disk Policy
Description Changes a virtual disk’s read, write, or cache policy.
Syntax
Example to
Example omconfig storage vdisk action=changepolicy controller=id vdisk=id [diskcachepolicy=<enabled|disabled> | readpolicy=<ra| nra| ara| rc|nrc> | writepolicy=<wb| wt| wc| nwc> | fwb> cachepolicy=<d | c>], where id is the controller ID and virtual disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
For more information about the controller-specific diskcache, read, write, and cache policy, see the Dell OpenManage Online Help. For information on specifying these parameters using the omconfig command, see the following:
• [readpolicy=<ra | nra | ara | rc | nrc>] parameter (optional)
• [writepolicy=<wb | wt | wc | nwc | fwb>] parameter (optional)
• [cachepolicy=<d | c>] Parameter (optional)
• [diskcachepolicy=<enabled|disabled>] parameter (optional)
Change the read policy of virtual disk 4 on controller 1 to no-read-ahead.
omconfig storage vdisk action=changepolicy controller=1 vdisk=4 readpolicy=nra
Omconfig Replace Member Virtual Disk
Description Replaces the member of a given virtual disk with the destination disk.
Syntax
Example to omconfig storage vdisk action=replacememberdisk controller=id vdisk=id source=<PDISKID> destination=<PDISKID>, where id is the controller ID and virtual disk ID as reported by the omreport command. The
<PDISK> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Replace physical disk 3 on connector 0 of controller 1 of virtual disk 4 with physical disk 5. On a Serial Attached SCSI (SAS) controller, the physical disk resides in enclosure 2.
Example for SCSI,
SATA, and ATA
Ccntrollers omconfig storage vdisk action=replacememberdisk controller=1 vdisk=4 source=0:3 destination=0:5
177
Example for SAS controllers omconfig storage vdisk action=replacememberdisk controller=1 vdisk=4 source=0:2:3 destination=0:2:5
Omconfig Rename Virtual Disk
Description Renames a virtual disk.
Syntax
Example to
Example omconfig storage vdisk action=rename controller=id vdisk=id name=<string>, where id is the controller ID and virtual disk ID as reported by the omreport command and <string> is the new name for the virtual disk.
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Rename virtual disk 4 on controller 1 to vd4.
omconfig storage vdisk action=rename controller=1 vdisk=4 name=vd4
Omconfig controller commands
The following table provides the omconfig command syntax required to execute controller tasks.
CAUTION: The omconfig storage controller action=resetconfig controller=id resets the controller configuration. Resetting the controller configuration permanently destroys all data on all virtual disks attached to the controller. System or boot partition residing on these virtual disks is destroyed.
NOTE: If the PERC hardware controller is running in HBA mode, you can perform only one action, exporting the log (action=exportlog).
Table 88. Omconfig Controller Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs omconfig storage controller action=rescan controller=id action=enablealarm controller=id action=disablealarm controller=id action=quietalarm controller=id action=testalarm controller=id action=resetconfig controller=id [force=yes] action=createvdisk controller=id raid=<c | r0 | r1| r1c | r5 | r6 | r10 | r50 | r60> size=<number | b | m | g | max | min> pdisk=<PDISKID> [stripesize=<
2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb | 256kb | 512kb | 1mb >]
[cachepolicy=<d | c>] [readpolicy=<ra | nra | ara | rc | nrc>]
[writepolicy=<wb | wt | wc | nwc | fwb>] [diskcachepolicy=<default |
178
Required Command Levels
(1, 2, 3)
Optional name=value pairs disabled | enabled>] [name=<string>] [spanlength=<n>] | [secureflag=yes]
[vdpienabled=yes]
NOTE: For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is an optional parameter (default=2).
action=setrebuildrate controller=id rate=<0 to 100> action=setchangecontrollerproperties controller=<id> [bgirate=<rate>]
[reconstructrate=<rate>][checkconsistencyrate=<rate>]
[rebuildrate=<rate>][clearredundantpath=clear] [rate=<0 to 100>]
[abortcheckconsistencyonerror=<enabled/disabled>][loadbalance=<auto/ disabled>][allowrevertiblehotspareandreplacemember=enabled/disabled]
[autoreplacememberonpredictivefailure=<enabled/disabled>]
[persistenthotspare=enabled/disabled][nrdiskcachepolicy=<enabled/ disabled/unchanged>] action=discardpreservedcache controller=id force=<enabled/disabled> action=createsecuritykey controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
NOTE: If you set escrow=yes, specify the escrow file path.
action=changesecuritykey controller=id keyid=<keyid> passphrase=<passphrase string> oldpassphrase=<oldpassphrase string>
[escrow=yes] [filepath=<Absolute path to the escrow file>]
NOTE: If you set escrow=yes, specify the escrow file path.
action=deletesecuritykey controller=id action=setbgirate controller=id rate=<0 to 100 > action=setreconstructrate controller=id rate=<0 to 100> action=setcheckconsistencyrate controller=id rate=<0 to 100> action=exportlog controller=id action=importsecureforeignconfig controller=id passphrase=<passphrase for imported foreign configuration> action=importforeignconfig controller=id action=importrecoverforeignconfig controller=id action=clearforeignconfig controller=id action=setpdiskpwrmanagement controller=id spindownunconfigureddrives=<enabled/disabled> spindownhotspares=<enabled/disabled> spindownconfigureddrives=<enabled/disabled> idlec=<enabled/disabled> spindowntimeinterval=<30 to 1440>(minutes) spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval=<1 to 24>(hours)
179
Required Command Levels
(1, 2, 3)
Optional name=value pairs
NOTE: Specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives=enabled.
action=setcontrollermode controller=id mode=<raid | hba> action=autoconfigureRAID0 controller=id action=setpatrolreadmode controller=id mode=<manual | auto | disable> action=startpatrolread controller=id action=stoppatrolread controller=id action=createcachecade controller=id pdisk=<PDISKID> [name=<string>] action=enablelkm controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
NOTE: If you set escrow=yes, specify the escrow file path.
action=switchtolkm controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
NOTE: If you set escrow=yes, specify the escrow file path.
action=rekeylkm controller=id action=convertraidtononraid controller=id pdisk=<PDISKID> action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Omconfig Rescan Controller
Description Rescans a controller. For more information, see the Dell OpenManage Online
Help .
Syntax
Example to omconfig storage controller action=rescan controller=id, where id is the controller ID as reported by the omreport storage controller command.
Rescan controller 1.
Example omconfig storage controller action=rescan controller=1
NOTE: The rescan controller is not supported on non-RAID SCSI and SAS controllers. Reboot the system to make the configuration changes visible on non-RAID SCSI controllers.
180
Omconfig Enable Controller Alarm
Description Enables the controller alarm. For more information, see the Dell OpenManage
Online Help .
Syntax
Example to omconfig storage controller action=enablealarm controller=id, where id is the controller ID as reported by the omreport storage controller command.
Enable the alarm on controller 1.
Example omconfig storage controller action=enablealarm controller=1
Omconfig Disable Controller Alarm
Description Disables the controller alarm. For more information, see the Dell OpenManage
Online Help .
Syntax
Example to
Example omconfig storage controller action=enablealarm controller=id, where id is the controller ID as reported by the omreport storage controller command.
Disable the alarm on controller 1.
omconfig storage controller action=disablealarm controller=1
Omconfig Quiet Controller Alarm
Table 89. omconfig Quiet Controller Alarm
Description Silences an activated controller alarm. For more information, see the Dell
OpenManage Online Help.
Syntax
Example to
Example omconfig storage controller action=quietalarm controller=id, where id is the controller ID as reported by the omreport storage controller command.
Quiet the alarm on controller 1.
omconfig storage controller action=quietalarm controller=1
181
omconfig Test Controller Alarm
Table 90. omconfig Test Controller Alarm
Description Tests the functionality of the controller alarm. The alarm sounds for about two seconds. For more information, see Dell OpenManage Online Help.
Syntax
Example to omconfig storage controller action=testalarm controller=id , where id is the controller ID as reported by the omreport storage controller command.
Test the alarm on controller 1.
Example omconfig storage controller action=testalarm controller=1
Omconfig Reset Controller Configuration
Description Resets the controller configuration.
CAUTION: Resetting a configuration permanently destroys all data on all virtual disks attached to the controller. System or boot partition residing on these virtual disks is destroyed. You may receive a warning message if this command results in deleting the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.
Syntax
Example to
Example omconfig storage controller action=resetconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.
In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage controller action=resetconfig controller=id force=yes
Reset the configuration on controller 1.
omconfig storage controller action=resetconfig controller=1
omconfig Create Virtual Disk
The Dell OpenManage Online Help provides additional information about creating virtual disks.
The omconfig syntax for creating a virtual disk has several parameters. You must specify the following parameters:
• Controller (controller=id)
• RAID level (raid=<c| r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>
182
• Size (size=<number | max | min>)>
Physical disk is specified as either:
• For SCSI, SATA, and ATA controllers: pdisk=connector:enclosureID:targetID where connector:enclosureID:targetID is the connector number, enclosure number, and slot number.
• For SAS controllers: pdisk=connector:targetID where connectorID:targetID is the connector number and the slot number. For example, pdisk=0:2
Storage Management supplies default values for any of the other parameters that you do not specify.
For creating an encrypted virtual disk, specify secureflag=yes. You can create encrypted virtual disks only with SED drives.
Complete Syntax: omconfig storage controller action=createvdisk controller=id raid=<c| r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>size=<number | max | min> pdisk=<PDISKID>
[stripesize=stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb | 128kb>]
[cachepolicy=<d | c>] [diskcachepolicy=<disabled | enabled>][readpolicy=<ra | nra | ara | rc | nrc>] [writepolicy=<wb| wt| wc| nwc | fwb>] [name=<string>]
[spanlength=<n>] | [secureflag=yes][vdpienabled=yes]
NOTE: If you are configuring RAID for SAS controllers with firmware version 6.1 and later, spanlength is an optional parameter (default=2). Spanlength is an even number and is lesser than or equal to half the number of physical disks specified in size.
NOTE: The vdpienabled is an optional argument and is valid only on PERC9 controllers. If set to yes a T10 Protection Information (PI) enabled virtual disk is created.
NOTE: For RAID 10 creation, PERC 9 firmware suggests the layout (number of array disks) with uneven span (spans with unequal number of array disks), though in a span the number of disks remains even. For example, for 32 disks, RAID 10 gets created with all the disks in one span and for
34 disks, RAID 10 gets created with 16 disks in one span and 18 disks in the other span.
Example Syntax:
You can create a RAID-5 virtual disk of 500 MB with a stripe size of 16 KB on a PERC 3/QC controller. The name of the virtual disk is vd1 and it resides on connector 0 of controller 1. Because the virtual disk is a
RAID-5, it requires at least three physical disks. In this example, you specify four physical disks. These are physical disks 0 through 3. The virtual disk has read-ahead, write–through caching, and cache I/O policies.
To create a virtual disk: omconfig storage controller action=createvdisk controller=1 raid=r5 size=500m pdisk= 0:0,0:1,0:2,0:3 stripesize=16kb cachepolicy=c readpolicy=ra writepolicy=wt
The only parameters that require specification are for the controller, RAID level, virtual disk size, and physical disk selection. Storage Management supplies default values for all other unspecified parameters.
For more information on read, write, and cache policies that are supported by the controller, see the Dell
OpenManage Online Help.
183
Parameter specification for creating and reconfiguring virtual disk
The following table displays how to specify the omconfig storage controller action=createvdisk parameters:
Table 91. Parameters And Types
Parameters Type controller=id Required raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> size=<number | max | min> pdisk=<connector:targetID,connector:targetID,.....
>
[stripesize=<2k b| 4kb | 8kb | 16kb | 32kb | 64kb |
128kb>]
[cachepolicy=<d | c>]
[readpolicy=<ra | nra | ara | rc | nrc>]
[writepolicy=<wb | wt | wc | nwc | fwb>]
[name=<string>]
[spanlength=<n>] parameter
Required
Required
Required
Optional
Optional
Optional
Optional
Optional
Optional controller=id parameter
Specify the controller ID as reported by the omreport storage controller command. For example,controller=2 raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>
Use the raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> parameter to specify a RAID level for a virtual disk.
Different controllers support different RAID levels. For more information about RAID levels a controller supports and for general information about RAID levels, see the Dell OpenManage Online Help. The following table displays how to specify the raid=n parameter for each RAID level.
Table 92. Raid level and parameter specification
RAID Level
RAID-0 raid=n Parameter Specification raid=r0
RAID-1
RAID-5 raid=r1 raid=r5
RAID-6
RAID-10
RAID-50
RAID-60 raid=r6 raid=r10 raid=r50 raid=r60 size=<number | max | min>
184
The following table displays how to specify the size=<number | max | min>
Table 93. Size Parameter
Description size=<number | max | min> Parameter
Specification size=<n> size=max size=min
Use this specification to indicate a specific size for the virtual disk. The virtual disk size is specified in b
(bytes), m (megabytes), or g (gigabytes). For example, size=500m indicates that the virtual disk is 500 MB.
To create a virtual disk that is the maximum size possible, specify size=max. When creating a
RAID-50 virtual disk, this parameter is specified as size=max.
To create a virtual disk that is the minimum size possible, specify size=min.
PDISKID=<connector:enclosureID:targetID | connector:targetID>
Use this parameter to specify the physical disks to be included in the virtual disk.
When reconfiguring a virtual disk, you must specify all physical disks to include in the reconfigured virtual disk. The physical disk specification applies to physical disks in the original virtual disk and continues in the reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk.
Some controllers allow you to remove a physical disk from a virtual disk. In this case, do not specify to remove the physical disk.
The pdisk=<PDISKID> parameter indicates a physical disk by specifying either connector:enclosureID:targetID or connector:targetID.
stripesize=<2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb>
Different controllers support different stripe sizes. For more information on stripe sizes supported for a controller, see the Dell OpenManage Online Help. All stripe sizes are specified in kilobytes. For example, when specifying 128 KB as the stripe size, type: stripesize=128kb cachepolicy=<d | c>] parameter
Different controllers support different cache policies. The following table displays how to specify the
[cachepolicy=<d | c>] parameter for each of the cache policies.
Table 94. Cache Policy Parameters
Cache Policy
Direct I/O
Cache I/O cachepolicy=d | c Parameter Specification cachepolicy=d cachepolicy=c diskcachepolicy=<disabled | enabled>
Different controllers support different disk cache policies. The following table indicates how to specify the [diskcachepolicy=<disabled | enabled>] parameter for each of the cache policies.
185
Table 95. Disk Cache Policy Parameters
Disk Cache Policy
Disabled
Enabled diskcachepolicy=disabled | enabled Parameter
Specification diskcachepolicy=disabled diskcachepolicy=enabled readpolicy=ra | nra | ara | rc | nrc>
Different controllers support different read policies. The following table displays how to specify the readpolicy=<ra | nra | ara | rc | nrc> parameter for each of the read policies.
Table 96. Read Policy Parameters
Read Policy
Read ahead
Adaptive read ahead
No read ahead
Read cache
No read cache readpolicy=ra | ara | nra | rc | nrc Parameter
Specification readpolicy=ra readpolicy=ara readpolicy=nra readpolicy=rc readpolicy=nrc writepolicy=<wb | wt | wc | nwc>]
Different controllers support different write policies. The following table displays how to specify the writepolicy=<wb | wt | wc | nwc | fwb> parameter for each of the write policies.
Table 97. Write Policy Parameters
Write Policy
Write-back cache
Write-through cache
Write cache
Force write back
No write cache writepolicy=wb | wt | wc | fwb | nwc Parameter
Specification writepolicy=wb writepolicy=wt writepolicy=wc writepolicy=fwb writepolicy=nwc
Controller=id
Specify the controller ID as reported by the omreport storage controller command. For example, controller=2
Raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>
Use the raid=<c| r0 | r1| r1c | r5 | r6 | r10 | r50 | r60> parameter to specify a RAID level for a virtual disk.
Different controllers support different RAID levels. For more information about RAID levels a controller supports and for general information about RAID levels, see the Dell OpenManage Online Help. The following table displays how to specify the raid=n parameter for each RAID level.
186
Table 98. Raid level and parameter specification
RAID level
RAID-0
RAID-1
RAID-5
RAID-6
RAID-10
RAID-50
RAID-60 raid=n parameter specification raid=r0 raid=r1 raid=r5 raid=r6 raid=r10 raid=r50 raid=r60 size=<number | max | min> Parameter
The following table displays how to specify the size=<number | max | min>
Table 99. Size Parameter size=<number | max | min> Parameter
Specification
Description size=<n> Use this specification to indicate a specific size for the virtual disk. The virtual disk size is specified in b
(bytes), m (megabytes), or g (gigabytes). For example, size=500m indicates that the virtual disk is 500 MB.
size=max size=min
To create a virtual disk that is the maximum size possible, specify size=max. When creating a
RAID-50 virtual disk, this parameter is specified as size=max.
To create a virtual disk that is the minimum size possible, specify size=min.
stripesize=< 2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb> stripesize=<2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb>
Different controllers support different stripe sizes. For more information on stripe sizes supported for a controller, see the Dell OpenManage Online Help. All stripe sizes are specified in kilobytes. For example, when specifying 128 KB as the stripe size, type: stripesize=128kb
PDISKID=<connector:enclosureID:targetID | connector:targetID>
PDISKID=<connector:enclosureID:targetID | connector:targetID>
Use this parameter to specify the physical disks to be included in the virtual disk.
When reconfiguring a virtual disk, you must specify all physical disks to include in the reconfigured virtual disk. The physical disk specification applies to physical disks in the original virtual disk and continues in the reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk.
Some controllers allow you to remove a physical disk from a virtual disk. In this case, do not specify to remove the physical disk.
187
The pdisk=<PDISKID> parameter indicates a physical disk by specifying either connector:enclosureID:targetID or connector:targetID.
Cachepolicy=<d | c> cachepolicy=<d | c>] Parameter
Different controllers support different cache policies. The following table displays how to specify the
[cachepolicy=<d | c>] parameter for each of the cache policies.
Table 100. Cache Policy Parameters
Cache Policy
Direct I/O
Cache I/O cachepolicy=d | c Parameter Specification cachepolicy=d cachepolicy=c
Diskcachepolicy=<disabled | enabled>
Different controllers support different disk cache policies. The following table indicates how to specify the [diskcachepolicy=<disabled | enabled>] parameter for each of the cache policies.
Table 101. Disk Cache Policy Parameters
Disk Cache Policy
Disabled
Enabled diskcachepolicy=disabled | enabled Parameter
Specification diskcachepolicy=disabled diskcachepolicy=enabled
Readpolicy=<ra | nra | ara | rc | nrc>]
Different controllers support different read policies. The following table displays how to specify the readpolicy=<ra | nra | ara | rc | nrc> parameter for each of the read policies.
Table 102. Read Policy Parameters
Read Policy
Read ahead
Adaptive read ahead
No read ahead
Read cache
No read cache readpolicy=ra | ara | nra | rc | nrc Parameter
Specification readpolicy=ra readpolicy=ara readpolicy=nra readpolicy=rc readpolicy=nrc
Writepolicy=<wb | wt | wc | nwc>
Different controllers support different write policies. The following table displays how to specify the writepolicy=<wb | wt | wc | nwc | fwb> parameter for each of the write policies.
Table 103. Write Policy Parameters
Write Policy
Write-back cache writepolicy=wb | wt | wc | fwb | nwc Parameter
Specification writepolicy=wb
188
Write-through cache
Write cache
Force write back
No write cache writepolicy=wt writepolicy=wc writepolicy=fwb writepolicy=nwc name=<string>
Use this parameter to specify a name for the virtual disk. For example:name=VirtualDisk1 spanlength=<n> (Required For RAID 50 And RAID 60 And Optional For RAID 10)
Use this parameter to specify the number of physical disks in each stripe. This parameter applies only to
RAID-50 virtual disks. If you are not creating a RAID-50 virtual disk, do not specify this parameter. For example: spanlength=3
For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is optional. Also, you can now specify the spanlength as an even number with a maximum of 8 spans with 32 physical disks each.
For example: omconfig storage controller action=createvdisk controller=1 raid=r10 size=min pdisk= 1:1:0,1:1:1,1:1:3,1:1:4,1:1:6,1:1:7,1:1:8,1:1:9 spanlength=4
Omconfig Set Controller Rebuild Rate
Descriptio n
Sets the controller rebuild rate.
Syntax omconfig storage controller action=setrebuildrate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.
Example to
Set the rebuild rate to 50 on controller 1.
Example omconfig storage controller action=setrebuildrate controller=1 rate=50
omconfig Change Controller Properties
Table 104. omconfig Change Controller Properties
Description Changes any or all of the controller properties.
Syntax omconfig storage controller action= setchangecontrollerproperties controller=<id> bgirate=<rate> reconstructrate=<rate> checkconsistencyrate=<rate> rebuildrate=<rate>
189
Example to
Example
Example to
Example clearredundantpath=clear abortcheckconsistencyonerror=<enabled | disabled> loadbalance=<auto | disabled> allowrevertiblehotspareandreplacemember
=<enabled | disabled> autoreplacememberonpredictivefailure=
<enabled | disabled> persistenthotspare=<enabled | disabled> nrdiskcachepolicy=<enabled | disabled | unchanged>
Enable revertible hot spare and replace member operation.
omconfig storage controller action= setchangecontrollerproperties allowrevertiblehotspare andreplacemember=enabled controller=1
Allows to enable, disable, or not to change the
Non-RAID Hard Disk Drives. This is applicable only to Disk Cache Policy.
omconfig storage controller action= setchangecontrollerproperties controller=1 nrdiskcachepolicy=enabled
Omconfig Discard Preserved Cache
Descriptio n
Discards the preserved cache on the controller.
NOTE: To check if the controller has a preserved cache, type omreport storage controller controller=id. If the system displays Preserved Cache=yes, it indicates the presence of the preserved cache.
Syntax omconfig storage controller action= discardpreservedcache controller=id force=enabled | disabled
If you set force=enabled, the cache is discarded irrespective of whether the controller detects a foreign or an offline virtual disk.
Example to
Discard the preserved cache.
Example omconfig storage controller action= discardpreservedcache controller=1 force=enabled
CAUTION: Discarding the preserved cache can result in data loss. It is recommended that you run this command using the force=disabled option.
190
NOTE: If a foreign configuration is detected, then the preceding command using force=disabled option fails. To avoid data loss, import the foreign configuration and flush the preserved cache to disk. To discard preserved cache forcefully, either clear the foreign configuration and run the proceeding command, or run the proceeding command using force=enabled option.
Omconfig Create Encryption Key
Descriptio n
Creates the encryption key for the controller.
Syntax omconfig storage controller action= createsecuritykey controller=id keyid=<keyid string> passphrase=<passphrase string>[escrow= yes]
[filepath=<Absolute path to the escrow file>]
Example to
Create the encryption key for the controller.
Example omconfig storage controller action= createsecuritykey controller=1 keyid=Dell_123 passphrase=Dell_123 escrow=yes filepath= C:/escrow.xml
NOTE: If you set escrow=yes, specify the escrow file path.
Omconfig Change Encryption Key
Descriptio n
Changes the encryption key for the controller, if passphrase is provided.
Syntax omconfig storage controller action= changesecuritykey controller=id keyid=<keyid string> passphrase=passphrase string> oldpassphrase=<old passphrase string>[escrow=yes] [filepath=<Absolute path to the escrow file>]>
Example to
Change the encryption key for the controller.
Example omconfig storage controller action= changesecuritykey controller=1 keyid=Dell_123 passphrase=Dell_123 oldpassphrase=Dell_321 escrow= yes filepath=C:/escrow.xml
NOTE: If you set escrow=yes, specify the escrow file path.
Omconfig Delete Encryption Key
Descriptio n
Deletes the encryption key for the controller.
Syntax omconfig storage controller action= deletesecuritykey controller=id, where id is the controller ID as reported by the omreport storage controller command.
191
Example to
Change the encryption key for the controller.
Example omconfig storage controller action= deletesecuritykey controller=1
Omconfig Set Background Initialization Rate
Descriptio n
Sets the background initialization rate.
Syntax
Example to omconfig storage controller action=setbgirate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.
Sets the background initialization rate to 50 on controller 1.
Example omconfig storage controller action=setbgirate controller=1 rate=50
Omconfig Set Reconstruct Rate
Descriptio n
Sets the reconstruct rate.
Syntax omconfig storage controller action= setreconstructrate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.
Example to
Set the reconstruct rate to 50 on controller 1.
Example omconfig storage controller action= setreconstructrate controller=1 rate=50
Omconfig Set Check Consistency Rate
Descriptio n
Sets the check consistency rate.
Syntax omconfig storage controller action= setcheckconsistencyrate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.
Example to
Sets the check consistency rate to 50 on controller 1.
Example omconfig storage controller action= setcheckconsistencyrate controller=1 rate=50
192
Omconfig Export The Controller Log
Descriptio n
Exports the controller log to a text file. For more information about the exported log file, see the Dell OpenManage Online Help.
Syntax
Example to omconfig storage controller action=exportlog controller=id, where id is the controller ID as reported by the omreport storage controller command.
Export the log on controller 1.
Example omconfig storage controller action=exportlog controller=1
By default, the log file is exported to C:\WINNT or C:\Windows on Microsoft Windows systems (based on the Windows version used) and /var/logon all Linux systems.
Depending on the controller, the log file name is afa_<mmdd>.log or lsi_<mmdd>.log where <mmdd> is the month and date. For more information on the controller log file, see the Dell OpenManage Online Help .
NOTE: The export log file command is not supported on the 4/IM, CERC ATA, and
100/4ch controllers.
Omconfig Import Secure Foreign Configuration
Descriptio n
Unlocks the encrypted Local Key Management (LKM) foreign configuration drives.
Syntax omconfig storage controller action= importsecureforeignconfig controller=id passphrase=<passphrase string for the foreign configuration>, where id is the controller ID as reported by the omreport storage controller command.
Example to
Unlock the ecncrypted LKM configuration drives on controller 1
Example omconfig storage controller action= importsecureforeignconfig controller=1 passphrase= Dell_123
Omconfig Import Foreign Configuration
Descriptio n
Imports all virtual disks that reside on physical disks newly attached to the controller.
Syntax omconfig storage controller action= importforeignconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.
NOTE: This command is supported only in firmware version 5.0.x.
Example to
Import foreign configurations on controller 1.
193
Example omconfig storage controller action= importforeignconfig controller=1
Omconfig Import Or Recover Foreign Configuration
Descriptio n
Imports and recovers all virtual disks that reside on physical disks newly attached to the controller.
Syntax omconfig storage controller action= importrecoverforeignconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.
NOTE: This command is supported only in firmware version 5.1.1.
Example to
Import foreign configurations on controller 1.
Example omconfig storage controller action= importrecoverforeignconfig controller=1
Omconfig Clear Foreign Configuration
Descriptio n
Clears or deletes all virtual disks that reside on physical disks newly attached to the controller.
Syntax omconfig storage controller action= clearforeignconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.
NOTE: This command is supported only in firmware version 5.0.x.
Example to
Clear foreign configurations on controller 1.
Example omconfig storage controller action= clearforeignconfig controller=1
Omconfig physical disk power management
Descriptio n
Manages the power of physical disks in a controller by spinning down hot spares, configured drives, and unconfigured drives.
Syntax omconfig storage controller action= setpdiskpwrmanagement spindownunconfigureddrives= <enabled | disabled> spindownhotspares=<enabled | disabled> spindownconfigureddrives=<enabled | disabled> idlec=<enabled | disabled> spindowntimeinterval=<30 to 1440>(minutes) spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval= <1 to 24>(hours), where id is the controller ID as reported by the omreport storage controller command.
NOTE: On PERC 7 controllers, only spindownunconfigureddrives, spindownhotspares, and spindowntimeinterval parameters are supported.
194
NOTE: You can specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives=enabled.
Spin down drives that are not configured or hot spares that are unattended for 30 minutes Example to
Example omconfig storage controller action= setpdiskpwrmanagement spindownunconfigureddrives= enabled spindownhotspares=enabled spindowntimeinterval=30 controller=1
Omconfig set controller mode
Descriptio n
Sets the mode of the controller to RAID or HBA.
Syntax
Example to omconfig storage controller action=setcontrollermode controller=id mode=raid|hba, where id is the controller ID as reported by the omreport storage controller command.
NOTE: If a virtual disk, hotspare, or encryption key is enabled on the controller, the controller mode cannot be changed to HBA. Reboot the system for the change to take effect.
Set the controller mode to HBA.
Example omconfig storage controller action=setcontrollermode controller=1 mode=hba
Omconfig autoconfigure RAID-0
Descriptio n
Automatically configures RAID–0 with all disks that are in ready state.
Syntax omconfig storage controller action=autoconfigureRAID0 controller=id , where id is the controller ID as reported by the omreport storage controller command.
Automatically configure RAID–0 with other disks.
Example to
Example omconfig storage controller action=autoconfigureRAID0 controller=1
Omconfig Set Patrol Read Mode
Descriptio n
Sets the patrol read mode for the controller.
Syntax omconfig storage controller action= setpatrolreadmode controller=id mode= manual|auto|disable, where id is the controller ID as reported by the omreport storage controller command.
195
Example to
Sets the patrol read on controller 1 to manual mode
Example omconfig storage controller action= setpatrolreadmode controller=1 mode=manual
Omconfig Start Patrol Read
Descriptio n
Starts the patrol read task on the controller.
Syntax omconfig storage controller action=startpatrolread controller=id, where id is the controller ID as reported by the omreport storage controller command.
Start the patrol read task on controller 1.
Example to
Example omconfig storage controller action=startpatrolread controller=1
NOTE: To start patrol read, the current patrol read mode is set to Manual.
Omconfig Stop Patrol Read
Descriptio n
Stops the patrol read task on the controller.
Syntax omconfig storage controller action=stoppatrolread controller=id, where id is the controller ID as reported by the omreport storage controller command.
Example to
Stop the patrol read task on controller 1.
Example omconfig storage controller action=stoppatrolread controller=1
NOTE: To stop patrol read, the current patrol read mode is set to Manual.
Omconfig Create Cachecade
Descriptio n
Creates a cachecade on the given controller.
Syntax omconfig storage controller action=createcachecade controller=id pdisk=<PDISKID> [name=<string>] where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as: pdisk=connector:enclosureID:targetID | connector:targetID
Example to
Create a cachecade on controller 0.
196
Example omconfig storage controller action=createcachecade controller=0 pdisk=0:2:3 name=Cachecade1
Omconfig Enable LKM Controller
Descriptio n
Enables the LKM mode and creates the encryption key for the controller.
Syntax omconfig storage controller action=enablelkm controller=id keyid=<keyid string> passphrase= <passphrase string> [escrow=yes]
[filepath= <Absolute path to the escrow file>, where id is the controller ID as reported by the omreport storage controller command.
Example to
Create the encryption key for the controller.
Example omconfig storage controller action=enablelkm controller=1 keyid=Dell_123 passphrase=Dell_123 escrow= yes filepath=C:/escrow.xml
NOTE: If you set escrow=yes, specify the escrow file path.
Omconfig Rekey LKM Controller
Descriptio n
Re-keys the encryption key in LKM mode for the controller.
Syntax
Example to omconfig storage controller action=rekeylkm controller=id keyid=<keyid> passphrase=<passphrase string> escrow=yes filepath=<Absolute path to the escrow file>, where id is the controller ID as reported by the omreport storage controller command.
Re-key the encryption key for the controller.
Example omconfig storage controller action=rekeylkm controller=1
Omconfig Convert Multiple RAID To Non-RAID
Description Converts multiple RAID to non-RAID on the given controller.
Syntax
Example to
Example omconfig storage controller action=convertraidtononraid controller=id pdisk=<PDISKID>, where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk=connector:enclosureID:targetID | connector:targetID.
Convert multiple non-RAID to RAID on controller 0.
omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3
197
Omconfig Convert Multiple Non-RAID To RAID
Description Converts multiple non-RAID to RAID on the given controller.
Syntax omconfig storage controller action=convertnonraidtoraid controller=id pdisk=<PDISKID>, where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk=connector:enclosureID:targetID | connector:targetID.
Example to
Example
Convert multiple non-RAID to RAID on controller 0, omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3
Omconfig Enclosure Commands
The following table provides the omconfig command syntax required to execute enclosure tasks.
Table 105. Omconfig Enclosure Commands
Optional name=value pairs Required Command
Levels (1, 2, 3) omconfig storage enclosure action=enablealarm controller=id enclosure=<ENCLOSUREID> action=disablealarm controller=id enclosure=<ENCLOSUREID> action=setassettag controller=id enclosure=<ENCLOSUREID> assettag=<string> action=setassetname controller=id enclosure=<ENCLOSUREID> assetname=<string> action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n action=resettempprobes controller=id enclosure=<ENCLOSUREID> index=id action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n action=resetalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n action=blink controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
Omconfig Enable Enclosure Alarm
Description Enables the enclosure alarm
Example to Enable the alarm on the enclosure attached to connector 2 on controller 1.
198
Example for SCSI,
SATA, and ATA controllers
Example for SAS controllers omconfig storage enclosure action=enablealarm controller=1 enclosure=2 omconfig storage enclosure action=enablealarm controller=1 enclosure=1:2
Omconfig Disable Enclosure Alarm
Table 106. Omconfig Disable Enclosure Alarm
Description Disables the enclosure alarm.
Syntax omconfig storage enclosure action=disablealarm controller=id enclosure=<ENCLOSUREID>, where idis the controller ID. The
<ENCLOSUREID> variable specifies the enclosure.
Disables the alarm on enclosure 2 attached to connector 1 on controller 1.
Example to
Example for SCSI,
SATA, and ATA controllers
Example for SAS controllers omconfig storage enclosure action=disablealarm controller=1 enclosure=2 omconfig storage enclosure action=disablealarm controller=1 enclosure=1:2
Omconfig Set Enclosure Asset Tag
Table 107. Omconfig Set Enclosure Asset Tag
Description Specifies the enclosure’s asset tag.
Syntax
Example to omconfig storage enclosure action=setassettag controller=id enclosure=<ENCLOSUREID> assettag=<string>, where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
In this syntax, <string> is a user-specified alphanumeric string.
Specify the asset tag to encl20 on the enclosure attached to connector 2 on controller.
Example for SCSI,
SATA, and ATA controllers
Example for SAS controllers omconfig storage enclosure action=setassettag controller=1 enclosure=2 assettag=encl20 omconfig storage enclosure action=setassettag controller=1 enclosure=1:2 assettag=encl20
199
Omconfig Set Enclosure Asset Name
Table 108. Omconfig Set Enclosure Asset Name
Description Specifies the asset name for an enclosure.
Syntax
Example to omconfig storage enclosure action=setassetname controller=id enclosure=<ENCLOSUREID> assetname=<string>, where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
In this syntax, <string> is a user-specified alphanumeric string.
Specify the asset name to encl43 for the enclosure attached to connector 2 on controller 1.
Example for SCSI,
SATA, and ATA controllers
Example for SAS controllers omconfig storage enclosure action=setassetname controller=1 enclosure=2 assetname=encl43 omconfig storage enclosure action=setassetname controller=1 enclosure=1:2 assetname=encl43
Omconfig Set Temperature Probe Thresholds
Table 109. Omconfig Set Temperature Probe Thresholds
Description Sets the minimum and maximum warning temperature thresholds for a specified temperature probe.
NOTE: This command is not supported on SAS controllers.
Syntax
Example to
Example for SCSI,
SATA, and ATA controllers omconfig storage enclosure action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n, where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Set the temperature probe thresholds to 10 and 40 degree Celsius.
omconfig storage enclosure action=settempprobes controller=1 enclosure=2 index=3 minwarn=10 maxwarn=40
NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.
Omconfig Reset Temperature Probe Thresholds
Table 110. Omconfig Reset Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default values.
200
Syntax
Example to
Example for SCSI,
SATA, and ATA controllers
NOTE: This command is not supported on SAS controllers.
omconfig storage enclosure action=resettempprobes controller=id enclosure=<ENCLOSUREID> index=id, where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Reset the thresholds for temperature probe 3, residing in the enclosure attached to connector 2 on controller 1, to the default values.
omconfig storage enclosure action=resettempprobes controller=1 enclosure=2 index=3
NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.
Omconfig Set All Temperature Probe Thresholds
Table 111. Omconfig Set All Temperature Probe Thresholds
Description Sets the minimum and maximum warning temperature thresholds for all temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax
Example to
Example for SAS controllers omconfig storage enclosure action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n, where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on controller 1, to 10 and 40 degree Celsius.
omconfig storage enclosure action=setalltempprobes controller=1 enclosure=2:3 minwarn=10 maxwarn=40
Omconfig Reset All Temperature Probe Thresholds
Table 112. oOmconfig Reset All Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax omconfig storage enclosure action=resetalltempprobes controller=id enclosure=<ENCLOSUREID>, where id is the controller ID.
The <ENCLOSUREID> variable specifies the enclosure.
201
Example to
In this syntax, n is a user-specified alphanumeric string.
Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1.
omconfig storage enclosure action= resetalltempprobes controller=1 enclosure=2:3
Example for SAS controllers
Omconfig Blink
Table 113. omconfig Blink
Description Blinks the light-emitting diodes (LEDs) on the enclosure.
Syntax omconfig storage enclosure action=blink controller=id enclosure=<ENCLOSUREID>, where id is the controller ID. The
<ENCLOSUREID> variable specifies the enclosure.
Example to
Example for SAS controllers
Example for SCSI,
SATA, and ATA controllers
Blink the LEDs for enclosure 3 attached to connector 2 on controller 1.
omconfig storage enclosure action=blink controller=1 enclosure=2:3 omconfig storage enclosure action=blink controller=1 enclosure=2
Omconfig Battery Commands
The following table displays the omconfig command syntax required to execute battery tasks.
Table 114. Omconfig Battery Commands
Optional name=value pairs Required Command
Levels (1, 2, 3) omconfig storage battery action=startlearn controller=id battery=id action=delaylearn controller=id battery=id days=d hours=h
omconfig Start Battery Learn Cycle
Table 115. Omconfig Start Battery Learn Cycle
Description Starts the battery learn cycle.
Syntax omconfig storage battery action=startlearn controller=id battery=id, where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=ID to display the ID for the controller battery.
202
Example to
Example
Start the learn cycle on controller 1.
omconfig storage battery action=startlearn controller=1 battery=0
Omconfig Delay Battery Learn Cycle
Table 116. Omconfig Delay Battery Learn Cycle
Description Delays the battery learn cycle for a specified period of time. You can delay the battery learn cycle for a maximum of seven days or 168 hours.
Syntax
Example to
Example omconfig storage battery action=delaylearn controller=id battery=id days=d hours=h, where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=ID to display the ID for the controller battery.
Delay the learn cycle for three days and 12 hours on controller 1.
omconfig storage battery action=delaylearn controller=1 battery=0 days=3 hours=12
Omconfig Global Commands
The following table displays the omconfig command syntax required to execute the global commands.
When executed, these commands apply to all controllers. These global commands also correspond to the global tasks provided by the Storage tree view object’s Information/Configuration subtab.
Table 117. Omconfig Global Commands
Optional name=value pairs Required Command
Levels (1, 2, 3) omconfig storage globalinfo action=enablests action=disablests action=globalrescan action=setprotectionpolicies type=ghs or dhs action=setremainingratedwriteendurancethreshold type=sassata | pcie threshold=<1-100>
Omconfig Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius. However, if you have implemented connector redundancy on the PV220S and PV221S enclosures you can specify that only the enclosure and not the operating system and server are shut down when the enclosure reaches a critical temperature of 0 or 50 degree
203
Celsius. Specifying that only the enclosure is shut down during excessive temperatures is known as Smart
Thermal Shutdown. For more information about Smart Thermal Shutdown, see the Dell OpenManage
Online Help.
Description
Syntax
Example to
Example
Enables smart thermal shutdown.
omconfig storage globalinfo action=enablests
Enable thermal shutdown. The omconfig command syntax for enabling thermal shutdown does not require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is also displayed by the
Server Administrator graphical user interface (GUI). To locate this status, select the Storage object and the Information/Configuration tab.
omconfig storage globalinfo action=enablests
Omconfig Global Disable Smart Thermal Shutdown
If you have previously enabled smart thermal shutdown using the omconfig command, you can disable smart thermal shutdown and return the system to its default setting. When smart thermal shutdown is disabled, the operating system and the server shuts down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius.
Description
Syntax
Example to
Example
Disables smart thermal shutdown for all controllers.
omconfig storage globalinfo action=disablests
Disable thermal shutdown. The omconfig command syntax for disabling thermal shutdown does not require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is also displayed in the GUI of Server Administrator. To locate this status, select the Storage object and the Information/Configuration tab.
omconfig storage globalinfo action=disablests
Omconfig Global Rescan Controller
Description Rescans all the controllers on the system. For more information about Global
Rescan Controller, see the Dell OpenManage Online Help.
Syntax omconfig storage globalinfo action=globalrescan
Example to Do a global rescan of all controllers. The omconfig command syntax for rescanning all controllers on the system does not require a controller or enclosure ID.
204
NOTE: Global rescan is not supported on non-RAID SCSI and SAS controllers. Reboot the system to make visible the configuration changes on non-RAID SCSI controllers.
omconfig storage globalinfo action=globalrescan Example
Omconfig Set Hot Spare Protection Policy
Table 118. Omconfig Set Hot Spare Protection Policy
Description Sets the hot spare protection policy for dedicated or global hot spares. For more information, see the Dell OpenManage Server Administrator Storage
Management User’s Guide at dell.com/support/manuals.
Syntax
Example for omconfig storage globalinfo action= setprotectionpolicies type=dhs raid=<r1 | r5 | r6 | r10 | r50 | r60 | all> hscount=<1-16> warnlevel=<0-3> includeghsinvdstate=<yes | no>, where hscount is the number of hot spares assigned to the virtual disk and warnlevel is the severity level you want to assign to the generated alert, if this policy is violated. Use hscount=0 warnlevel=0 to reset the dedicated hot spare protection policy for the RAID level.
Global hot spare protection policy
Example omconfig storage globalinfo action=setprotectionpolicies type=dhs hscount=1 warnlevel=1 includeghsinvdstate=yes
Omconfig Global threshold for remaining rated write endurance
Description Sets the threshold value for Remaining Rated Write Endurance (RRWE) SMART attribute for SSDs. When the remaining rate write endurance threshold drops below the configured threshold, an alert is logged. For more information about
Global Threshold for Remaining Rated Write Endurance, see the Dell
OpenManage Online Help.
Syntax
Example to omconfig storage globalinfo action=setremainingratedwriteendurancethreshold type=<sassata| pcie> threshold=<1-100>
Settings supported for different threshold values for SAS, SATA and PCIe SSDs.
The omconfig command syntax for Threshold RRWE value is set between 0 to
100.
NOTE: The RRWE SMART attribute is not supported for SSDs connected to software RAID Controllers.
Example omconfig storage globalinfo action=setremainingratedwriteendurancethreshold type=sassata threshold=0.
205
Omconfig Connector Commands
The following table displays the omconfig command syntax required to execute connector tasks.
Table 119. omconfig Connector Commands
Optional name=value pairs Required Command
Levels (1, 2, 3) omconfig storage connector action=rescan controller=id connector=id
Omconfig Rescan Connector
Description Rescans a controller connector. This command rescans all connectors on the controller and is therefore similar to performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Syntax
Example to
Example omconfig storage connector action=rescan controller=id connector=id, where id is the controller ID and the connector ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage connector controller=ID to display the IDs for the connectors attached to the controller.
Rescan connector 2 on controller 1.
omconfig storage connector action=rescan controller=1 connector=2
Omconfig cachecade commands
The following table displays the omconfig command syntax required to execute cachecade tasks.
Table 120. omconfig Cachecade Commands
Optional name=value pairs Required Command
Levels (1, 2, 3) omconfig storage cachecade action=blink controller=id cachecade=id action=unblink controller=id cachecade=id action=deletecachecade controller=id cachecade=id [force=yes] action=resize controller=id cachecade=id pdisk= <PDISKID> action=rename controller=id cachecade=id name=<string>
206
Omconfig Blink Cachecade
Description Blinks the physical disks included in a cachecade.
Syntax omconfig storage cachecade action=blink controller=id cachecade=id, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.
Example to
Example
Blinks the physical disk in cachecade 4 on controller 1 omconfig storage cachecade action=blink controller=1 cachecade=4
Omconfig Unblink Cachecade
Description Unblinks the physical disks included in a cachecade.
Syntax omconfig storage cachecade action=unblink controller=id cachecade=id, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.
Example to
Example
Unblinks the physical disk in cachecade 4 on controller 1 omconfig storage cachecade action=unblink controller=1 cachecade=4
Omconfig Delete Cachecade
Description Deletes a cachecade.
Syntax
Example to omconfig storage cachecade action=deletecachecade controller=id cachecade=id, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.
In some circumstances, you may receive a warning message. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage cachecade action=deletecachecade controller=id cachecade=id force=yes
Delete cachecade 4 on controller 1.
207
Example omconfig storage cachecade action=deletecachecade controller=1 cachecade=4
Omconfig Resize Cachecade
Description Resizes a cachecade by adding or removing physical disks.
Syntax
Example to
Example for SAS controllers
Example for SCSI,
SATA, and ATA controllers omconfig storage cachecade action=resize controller=id cachecade=id pdisk=<PDISKID>, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.
Resize cachecade 4, use physical disks 0 through 3 on connector 0 of controller
1.
omconfig storage cachecade action=resize controller=1 cachecade=4 pdisk= 0:2:0,0:2:1,0:2:2,0:2:3 omconfig storage cachecade action=resize controller=1 cachecade=4 pdisk=0:0,0:1,0:2,0:3
Omconfig Rename Cachecade
Description Renames a cachecade.
Syntax
Example to
Example omconfig storage cachecade action=rename controller=id cachecade=id name=<string>, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.
Rename cachecade 4 on controller 1 to cc4.
omconfig storage cachecade action=rename controller=1 cachecade=4 name=cc4
Omconfig NVMe adapter configuration commands
The following table displays the omconfig command syntax required to configure NVMe device properties.
208
Table 121. omconfig NVMe adapter commands
Required Command
Levels (1, 2, 3) omconfig storage nvmeadapter
Optional name=value pairs action=exportlog controller=id nvmeid=id action=cryptographicerase controller=id nvmeid=id
Omconfig exporting controller log
Description Exports the NVMe PCIeSSD adapter reliability log of the Samsung NVMe adapter.
The controller log is exported to the Windows folder on systems running
Windows, and to /var/log directory on systems running Linux.
NOTE: Depending on the device, the log file name for the NVMe PCIeSSD adapter NVME_<device name>_<timestamp>.log where <device name> is the name of the device and timestamp is month, day, hour, minute and second during which the command is executed.
Syntax omconfig storage nvmeadapter action=exportlog controller=id nvmeid=<NVMe adapter>
Example to
Example
Export the log of controller 1 on the NVMe adapter 1.
omconfig storage nvmeadapter action=exportlog controller=1 nvmeid=1
Omconfig cryptographic erase
Description Erases the specified NVMe device.
NOTE: This option is supported only on NVMe devices.
Syntax
Example to
Example omconfig storage nvmeadapter action=cryptographicerase controller=id nvmeid=<PCI slot>
Erase the NVMe device on the PCI slot 1 of controller 1.
omconfig storage nvmeadapter action=cryptographicerase controller=1 nvmeid=1
209
9
Working With CLI Command Results
Server Administrator Command Line Interface (CLI) users can use the command output in various ways.
This chapter explains how to save command output to a file and how to select a format for the command results that fits different objectives. The following table displays the systems on which omreport commands are applicable.
Table 122. System Availability For The omreport Command
Command Level 1 omreport
Command Level 2 modularenclosure servermodule mainsystem system chassis
Applicable To
Blade systems
Blade systems
Blade systems
Rack and Tower systems
Rack and Tower systems
Output Options For Command Results
CLI command output displays to standard output on the system in a command window, in an X-terminal, or on a screen, depending on the type of the operating system.
You can redirect command results to a file instead of displaying them to standard output. Saving command output to a file allows you to use the command output for later analysis or comparison.
Whether you display command results to standard output or have the command results written to a file, you can format the results. The format you select determines the way the command output is displayed and the way the command output is written to a file.
Controlling command output display
Each operating system provides a means of controlling the way that command results display to standard output. The following is a useful command for ensuring that command results do not scroll by before you can view them. The same command syntax works for the Microsoft Windows command prompt, the
Red Hat Enterprise Linux terminal, and the SUSE Linux Enterprise Server terminal. To display command output with control over scrolling, type the CLI command and append the pipe symbol followed by more.
For example, type: omreport system summary | more or omreport servermodule summary | more
210
The multiscreen system summary displays the first screen. When you want to see the next screen of command output, press the spacebar.
Writing Command Output To A File
When redirecting command results to a file, you can specify a filename (and a directory path if necessary) to which you want to write the command result. When specifying the path to which you want to write the file, use the appropriate syntax for the operating system.
You can save command results in two ways. You can overwrite any file that has the same name as the output file you specify, or you can keep adding results of commands to a file of the same name.
Saving Command Results To A File That Is Overwritten
Use the -outc option when you want to overwrite data stored in previously written files. For example, at
11:00 A.M. you capture fan probe RPM readings for fan probe 0 on the system and write the results to a file called fans.txt. You type: omreport chassis fans index=0 -outc fans.txt
or omreport mainsystem fans index=0 -outc fans.txt
Partial results written to the file are:
Index
Status
Probe Name
Reading
Minimum Warning Threshold
Maximum Warning Threshold
Minimum Failure Threshold
Maximum Failure Threshold
: 0
: OK
: System Board Fan 1 RPM
: 2380RPM
: 600RPM
: 5700RPM
: 500RPM
: 6000RPM
Four hours later, you repeat the command. You have no interest in the 11:00 A.M. snapshot as written to fans.txt. You type the same command: omreport chassis fans index=0 -outc fans.txt
or omreport mainsystem fans index=0 -outc fans.txt
The 3:00 P.M. data overwrites the 11:00 A.M. data in the fans.txt file.
Fans.txt now reads as follows:
Index
Status
: 0
: OK
211
Probe Name
Reading
Minimum Warning Threshold
Maximum Warning Threshold
Minimum Failure Threshold
Maximum Failure Threshold
: System Board Fan 1 RPM
: 3001RPM
: 700RPM
: 5500RPM
: 500RPM
: 6000RPM
You cannot refer to the previous command results to compare the earlier fan probe 0 output with the present output because in using the -outc option, you overwrote the fans.txt file.
Append command results to an existing file
Use the -outa option when you want to append new command results to data stored in a previously written file. For example, at 11:00 A.M. you capture fan probe RPM readings for fan probe 0 on the system and write the results to a file called fans.txt. To compare these results with output for the same probe obtained four hours later, you can use the -outa command to append the new output to fans.txt.
Type: omreport chassis fans index=0 -outa fans.txt
or omreport mainsystem fans index=0 -outa fans.txt
Fans.txt now reads as follows:
Index
Status
Probe Name
Reading
Minimum Warning
Threshold
Maximum Warning
Threshold
Minimum Failure
Threshold
Maximum Failure
Threshold
: 0
: OK
: System Board Fan 1 RPM
: 2380RPM
: 600RPM
: 5700RPM
: 500RPM
: 6000RPM
Index
Status
Probe Name
Reading
: 0
: OK
: System Board Fan 1 RPM
: 3622RPM
212
Minimum Warning
Threshold
Maximum Warning
Threshold
Minimum Failure
Threshold
Maximum Failure
Threshold
: 900RPM
: 3500RPM
: 500RPM
: 6000RPM
You can use a text editor to insert the time that each block of data was captured. In comparing the two snapshots for fan probe 0, you can see that the second report shows several changes. The reading of fan
RPM has increased by 621 RPM but is still within normal range. Someone has raised the minimum warning threshold by 200 RPM and has decreased the maximum warning threshold by 2000 RPM.
Selecting A Format For The CLI Command Output
You can specify a format for the CLI command results. The format determines how the command output is displayed. If the command results are directed to a file, the format is captured by the file to which you write the command results.
The available formats include:
• List (lst)
• Semicolon-separated values (ssv)
• Table (tbl)
• Custom delimited format (cdv)
The syntax for the formatting option is:
<command> -fmt <format option>
For example, type: omreport system summary -fmt tbl or omreport servermodule summary -fmt tbl where -fmt tbl specifies table format.
You can combine the formatting option with the option to direct output to a file. For example, type: omreport system summary -fmt tbl -outa summary.txt
or omreport servermodule summary -fmt tbl -outa summary.txt
where -fmt tbl specifies table format and -outa specifies that you append the command results to a file named summary.txt .
213
List (lst)
The default format is lst or list format. Use this format when you want to optimize output for simple readability. You need to specify a format for the command output only if you want a format other than the lst format.
To see the following example command output in lst format, type: omreport system summary or omreport servermodule summary
No special formatting option is required because list format is the default display format. The network data part of the example system summary is displayed as follows:
--------------
Network Data
--------------
Network Interface 0
IP Address : 143.166.152.108
Subnet Mask : 255.255.255.0
Default Gateway : 143.166.152.1
MAC Address : 00-02-b3-23-d2-ca
Table (tbl)
Use the tbl or table formatting option to have the data formatted in table rows and columns. To see the following example command output in table format, type: omreport system summary -fmt tbl or omreport servermodule summary -fmt tbl
The example output displays as follows:
------------------------------
Network Interface 0
------------------------------
| ATTRIBUTE | VALUE
| IP Address | 143.166.152.108
| Subnet Mask | 255.255.255.0
| Default Gateway | 143.166.152.1
| MAC Address | 00-02-b3-23-d2-ca
Semicolon-Separated Values (ssv)
Use the ssv formatting option to deliver output formatted in semicolon-separated value format. This format also allows you to import the command output results into a spreadsheet program such as
Microsoft Excel, or into a database program. To see the following example command output in semicolon-separated value format, type: omreport system summary -fmt ssv or omreport servermodule summary -fmt ssv
214
The example output displays as follows:
------------------------------
Network Data
------------------------------
Network Interface 0
IP Address;143.166.152.108
Subnet Mask;255.255.255.0
Default Gateway;143.166.152.1
MAC Address;00-02-b3-23-d2-ca
Custom delimited format (cdv)
Use the cdv formatting option to report exported data in custom delimited format. You can specify this option with any omreport command. For example, to generate a system summary in custom delimited format, type: omreport system summary -fmt cdv or omreport servermodule summary -fmt cdv
You can also set preferences for the custom delimited format with the omconfig command. The valid values for delimiters are: exclamation, semicolon, at, hash, dollar, percent, caret, asterisk, tilde, question, colon, comma, and pipe.
The following example shows how to set the delimiter for separating data fields to asterisk: omconfig preferences cdvformat delimiter=asterisk
215
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Dell OpenManage Server Administrator Version 8.3 Command Line Interface Guide
- 10 Introduction
- 10 What is new in this release
- 11 Accessing the windows command prompt to run CLI commands
- 11 Primary CLI Commands
- 12 CLI error checking and error messages
- 12 Success Messages
- 12 Failure Messages
- 13 Scripting And Comparing Using CLI
- 14 Command syntax overview
- 15 Using The omhelp Command
- 15 Example Help Commands
- 17 omreport: Viewing System Status Using The Instrumentation Service
- 17 Conventions for parameter tables
- 18 Command summary of the omreport command
- 21 Help With The omreport Command
- 21 omreport modularenclosure
- 22 omreport about
- 23 Omreport Chassis Or Omreport Mainsystem Commands
- 24 Chassis management
- 24 Omreport chassis acswitch or omreport mainsystem acswitch
- 25 Omreport Chassis Batteries Or Omreport Mainsystem Batteries
- 25 Omreport Chassis Bios Or Omreport Mainsystem Bios
- 25 Omreport chassis biossetup or omreport mainsystem biossetup
- 26 BIOS setup groups
- 26 Omreport Chassis Currents Or Omreport Mainsystem Currents
- 26 Omreport chassis fans or omreport mainsystem fans
- 27 Omreport Chassis Firmware Or Omreport Mainsystem Firmware
- 27 Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel
- 27 Omreport Chassis Fru Or Omreport Mainsystem Fru
- 28 Omreport chassis hwperformance or omreport mainsystem hwperformance
- 28 Omreport Chassis Info Or Omreport Mainsystem Info
- 29 Omreport Chassis Intrusion
- 29 Omreport Chassis Leds Or Omreport Mainsystem Leds
- 30 Omreport Chassis Memory Or Omreport Mainsystem Memory
- 32 Omreport chassis nics or omreport mainsystem nics
- 33 Omreport Chassis Ports Or omreport Mainsystem Ports
- 33 Omreport Chassis Processors Or Omreport Mainsystem Processors
- 36 Omreport chassis pwrmanagement or omreport mainsystem pwrmanagement
- 37 Omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring
- 39 Omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
- 39 Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
- 40 Omreport Chassis Removableflashmedia Or Omreport Mainsystem Removableflashmedia
- 41 Omreport Chassis Slots Or Omreport Mainsystem Slots
- 41 Omreport chassis temps or Omreport mainsystem temps
- 42 Omreport Chassis Volts Or Omreport Mainsystem Volts
- 42 Omreport Licenses
- 43 Omreport System Commands Or Omreport Servermodule Commands
- 43 Omreport System Or Omreport Servermodule
- 43 Commands for viewing logs
- 44 Omreport System Alertaction Or Omreport Servermodule Alertaction
- 45 Omreport System Assetinfo Or Omreport Servermodule Assetinfo
- 46 Omreport system events or omreport servermodule events
- 46 Omreport System Events Type Or Omreport Servermodule Events Type
- 47 Omreport System snmptrapdest Or Omreport Servermodule snmptrapdest
- 48 Omreport System Operatingsystem Or Omreport Servermodule Operatingsystem
- 48 Omreport System Pedestinations Or Omreport Servermodule Pedestinations
- 49 Omreport System Platformevents Or Omreport Servermodule Platformevents
- 50 Omreport System Recovery Or Omreport Servermodule Recovery
- 50 Omreport System Shutdown Or Omreport Servermodule Shutdown
- 50 Omreport System Summary Or Omreport Servermodule Summary
- 55 Omreport System Thrmshutdown Or Omreport Servermodule Thrmshutdown
- 55 Omreport System Version Or Omreport Servermodule Version
- 56 Omreport Preferences Commands
- 56 Omreport Preferences Messages
- 56 Omreport preferences logging
- 57 Omreport preferences webserver
- 58 Omconfig: Managing Components Using The Instrumentation Service
- 58 Conventions for parameter tables
- 59 omconfig Command Summary
- 61 Help With The Omconfig Command
- 62 Omconfig About
- 63 Omconfig Chassis Or Omconfig Mainsystem
- 63 Omconfig Chassis Biossetup Or Omconfig Mainsystem Biossetup
- 82 Omconfig Chassis Currents Or Omconfig Mainsystem Currents
- 82 Omconfig Chassis Fans Or Omconfig Mainsystem Fans
- 83 Omconfig chassis frontpanel or omconfig mainsystem frontpanel
- 84 Omconfig Chassis Info Or Omconfig Mainsystem Info
- 85 Omconfig Chassis Leds Or Omconfig Mainsystem Leds
- 86 Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode
- 87 Omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement
- 89 Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring
- 91 Omconfig chassis remoteaccess or omconfig mainsystem remoteaccess
- 100 Omconfig Chassis Temps Or Omconfig Mainsystem Temps
- 101 Omconfig Chassis Volts Or Omconfig Mainsystem Volts
- 102 Omconfig Preferences
- 102 Omconfig Preferences Cdvformat
- 102 Omconfig Preferences Dirservice
- 103 Omconfig Preferences Messages
- 103 Omconfig Preferences Useraccess
- 104 Omconfig Preferences Logging
- 105 Omconfig preferences webserver
- 118 Omconfig System Or Omconfig Servermodule
- 119 Omconfig System Alertaction Or Omconfig Servermodule Alertaction
- 122 Commands for clearing logs
- 123 Omconfig system pedestinations or omconfig servermodule pedestinations
- 123 Omconfig system platformevents or omconfig servermodule platformevents
- 126 Omconfig system snmptraptest or omconfig servermodule snmptraptest
- 126 Omconfig System Events Or Omconfig Servermodule Events
- 128 Omconfig System Webserver Or Omconfig Servermodule Webserver
- 128 Omconfig System Recovery Or Omconfig Servermodule Recovery
- 129 Omconfig System Shutdown Or Omconfig Servermodule Shutdown
- 130 Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown
- 132 Omconfig System Or Servermodule Assetinfo: Editing Cost Of Ownership Values
- 132 Adding acquisition information
- 134 Example command for adding acquisition information
- 134 Adding depreciation information
- 135 Example command for adding depreciation information
- 135 Adding extended warranty information
- 136 Example command for adding extended warranty information
- 136 Adding lease information
- 137 Example command for adding lease information
- 137 Adding maintenance information
- 138 Example command for adding maintenance information
- 138 Adding outsource information
- 139 Example command for adding outsource information
- 139 Adding owner information
- 140 Example command for adding owner information
- 140 Adding service contract information
- 140 Example command for adding service information
- 141 Adding support information
- 141 Example command for adding support information
- 142 Adding system information
- 142 Example command for adding system information
- 142 Adding warranty information
- 143 Example command for adding warranty information
- 144 Using The Storage Management Service
- 144 CLI command syntax
- 145 Syntax Of Command Elements
- 146 User Privileges For Omreport Storage And Omconfig Storage
- 147 Omreport storage commands
- 148 Omreport Physical Disk Status
- 149 omreport Virtual Disk Status
- 149 Omreport controller status
- 149 Omreport Enclosure Status
- 150 Omreport Temperature Probe Status
- 151 Omreport Fan Status
- 151 Omreport Power Supply Status
- 152 Omreport EMM Status
- 152 Omreport Enclosure Slot Occupancy Report
- 153 Omreport Battery Status
- 153 Omreport Global Information
- 154 Omreport Connector Status
- 154 Omreport Cachecade Status
- 155 Omreport PCIe SSD Status
- 155 Omreport Storage Tape
- 155 Omreport NVMe adapter
- 157 Omconfig storage commands
- 158 Omconfig Physical Disk Commands
- 158 Omconfig Blink Physical Disk
- 159 Omconfig Unblink Physical Disk
- 160 Omconfig Prepare To Remove Physical Disk
- 160 Omconfig Instant Erase Secured Physical Disk
- 161 Omconfig Cryptographic Erase Secured Physical Disk
- 161 Omconfig Initialize Physical Disk
- 162 Omconfig Offline Physical Disk
- 162 Omconfig Online Physical Disk
- 163 Omconfig Assign Global Hot Spare
- 163 Omconfig Rebuild Physical Disk
- 164 Omconfig Cancel Rebuild Physical Disk
- 164 Omconfig Cancel Replace Member
- 165 Omconfig Clear Physical Disk
- 165 Omconfig cancel clear physical disk
- 166 Omconfig Enable Device Write Cache
- 166 Omconfig Disable Device Write Cache
- 167 Omconfig Export Reliability Log
- 167 Omconfig Convert RAID To Non-RAID
- 168 Omconfig Convert Non-RAID To RAID
- 168 Omconfig Set array disk cache
- 169 Omconfig virtual disk commands
- 170 Omconfig Check Consistency
- 170 Omconfig cancel check consistency
- 171 Omconfig Pause Check Consistency
- 171 Omconfig Resume Check Consistency
- 171 Omconfig blink virtual disk
- 172 Omconfig Unblink Virtual Disk
- 172 Omconfig Initialize Virtual Disk
- 172 Omconfig Fast Initialize Virtual Disk
- 173 Omconfig Slow Initialize Virtualize Disk
- 173 Omconfig cancel initialize virtual disk
- 174 Omconfig cancel background initialize
- 174 Omconfig Assign Dedicated Hot Spare
- 174 Omconfig Delete Virtual Disk
- 175 Omconfig reconfiguring virtual disks
- 176 Omconfig Secure Virtual Disk
- 176 Omconfig Clear Virtual Disk Bad Blocks
- 177 Omconfig Change Virtual Disk Policy
- 177 Omconfig Replace Member Virtual Disk
- 178 Omconfig Rename Virtual Disk
- 178 Omconfig controller commands
- 180 Omconfig Rescan Controller
- 181 Omconfig Enable Controller Alarm
- 181 Omconfig Disable Controller Alarm
- 181 Omconfig Quiet Controller Alarm
- 182 omconfig Test Controller Alarm
- 182 Omconfig Reset Controller Configuration
- 182 omconfig Create Virtual Disk
- 189 Omconfig Set Controller Rebuild Rate
- 189 omconfig Change Controller Properties
- 190 Omconfig Discard Preserved Cache
- 191 Omconfig Create Encryption Key
- 191 Omconfig Change Encryption Key
- 191 Omconfig Delete Encryption Key
- 192 Omconfig Set Background Initialization Rate
- 192 Omconfig Set Reconstruct Rate
- 192 Omconfig Set Check Consistency Rate
- 193 Omconfig Export The Controller Log
- 193 Omconfig Import Secure Foreign Configuration
- 193 Omconfig Import Foreign Configuration
- 194 Omconfig Import Or Recover Foreign Configuration
- 194 Omconfig Clear Foreign Configuration
- 194 Omconfig physical disk power management
- 195 Omconfig set controller mode
- 195 Omconfig autoconfigure RAID-0
- 195 Omconfig Set Patrol Read Mode
- 196 Omconfig Start Patrol Read
- 196 Omconfig Stop Patrol Read
- 196 Omconfig Create Cachecade
- 197 Omconfig Enable LKM Controller
- 197 Omconfig Rekey LKM Controller
- 197 Omconfig Convert Multiple RAID To Non-RAID
- 198 Omconfig Convert Multiple Non-RAID To RAID
- 198 Omconfig Enclosure Commands
- 198 Omconfig Enable Enclosure Alarm
- 199 Omconfig Disable Enclosure Alarm
- 199 Omconfig Set Enclosure Asset Tag
- 200 Omconfig Set Enclosure Asset Name
- 200 Omconfig Set Temperature Probe Thresholds
- 200 Omconfig Reset Temperature Probe Thresholds
- 201 Omconfig Set All Temperature Probe Thresholds
- 201 Omconfig Reset All Temperature Probe Thresholds
- 202 Omconfig Blink
- 202 Omconfig Battery Commands
- 202 omconfig Start Battery Learn Cycle
- 203 Omconfig Delay Battery Learn Cycle
- 203 Omconfig Global Commands
- 203 Omconfig Global Enable Smart Thermal Shutdown
- 204 Omconfig Global Disable Smart Thermal Shutdown
- 204 Omconfig Global Rescan Controller
- 205 Omconfig Set Hot Spare Protection Policy
- 205 Omconfig Global threshold for remaining rated write endurance
- 206 Omconfig Connector Commands
- 206 Omconfig Rescan Connector
- 206 Omconfig cachecade commands
- 207 Omconfig Blink Cachecade
- 207 Omconfig Unblink Cachecade
- 207 Omconfig Delete Cachecade
- 208 Omconfig Resize Cachecade
- 208 Omconfig Rename Cachecade
- 208 Omconfig NVMe adapter configuration commands
- 209 Omconfig exporting controller log
- 209 Omconfig cryptographic erase
- 210 Working With CLI Command Results
- 210 Output Options For Command Results
- 210 Controlling command output display
- 211 Writing Command Output To A File
- 211 Saving Command Results To A File That Is Overwritten
- 212 Append command results to an existing file
- 213 Selecting A Format For The CLI Command Output
- 214 List (lst)
- 214 Table (tbl)
- 214 Semicolon-Separated Values (ssv)
- 215 Custom delimited format (cdv)