Dell OpenManage Server Administrator Version 7.4 software Reference Guide


Add to my manuals
204 Pages

advertisement

Dell OpenManage Server Administrator Version 7.4 software Reference Guide | Manualzz

Dell OpenManage Server Administrator

Version 7.4 Command Line Interface Guide

Notes, Cautions, and Warnings

NOTE: A NOTE indicates important information that helps you make better use of your computer.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell ™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

2014 - 03

Rev. A00

Contents

1 Introduction.........................................................................................................10

What's New In This Release

................................................................................................................ 10

Accessing The Windows Command Prompt To Run CLI Commands

............................................. 12

Primary CLI Commands

...................................................................................................................... 12

CLI Error Checking And Error Messages

.............................................................................................13

Success Messages

..........................................................................................................................13

Failure Messages

............................................................................................................................ 13

Scripting And Comparing Using CLI

...................................................................................................14

Command Syntax Overview

................................................................................................................15

2 Using The omhelp Command...........................................................................16

Example Help Commands

.................................................................................................................. 16

3 omreport: Viewing System Status Using The Instrumentation Service... 18

Conventions For Parameter Tables

.................................................................................................... 18

Command Summary Of The omreport Command

........................................................................... 19

Help With The omreport Command

.................................................................................................. 22 omreport modularenclosure

.............................................................................................................. 22

omreport about

...................................................................................................................................23

Omreport Chassis Or Omreport Mainsystem Commands

............................................................... 24

Omreport Chassis Acswitch Or Omreport Mainsystem Acswitch

.............................................. 25

Omreport Chassis Batteries Or Omreport Mainsystem Batteries

............................................... 25

Omreport Chassis Bios Or Omreport Mainsystem Bios

.............................................................. 26

Omreport Chassis Biossetup Or Omreport Mainsystem Biossetup

............................................26

BIOS Setup Parameters On Systems Prior To PowerEdge 12G Systems

....................................26

BIOS Setup Groups On PowerEdge yx2x Systems

...................................................................... 29

Omreport Chassis Currents Or Omreport Mainsystem Currents

............................................... 29

Omreport Chassis Fans Or Omreport Mainsystem Fans

.............................................................30

Omreport Chassis Firmware Or Omreport Mainsystem Firmware

............................................. 30

Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel

........................................ 30

Omreport Chassis Fru Or Omreport Mainsystem Fru

..................................................................31

Omreport Chassis Hwperformance Or Omreport Mainsystem Hwperformance

...................... 31

Omreport Chassis Info Or Omreport Mainsystem Info

............................................................... 31

Omreport Chassis Intrusion

..........................................................................................................32

Omreport Chassis Leds Or Omreport Mainsystem Leds

.............................................................32

Omreport Chassis Memory Or Omreport Mainsystem Memory

.................................................33

Omreport Chassis Nics Or Omreport Mainsystem Nics

..............................................................35

Omreport Chassis Ports Or omreport Mainsystem Ports

............................................................36

Omreport Chassis Processors Or Omreport Mainsystem Processors

........................................36

Omreport Chassis Pwrmanagement Or Omreport Mainsystem Pwrmanagement

...................39

Omreport Chassis Pwrmonitoring Or Omreport Mainsystem Pwrmonitoring

..........................40

Omreport Chassis Pwrsupplies Or Omreport Mainsystem Pwrsupplies

.................................... 42

Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess

........................... 42

Omreport Chassis Removableflashmedia Or Omreport Mainsystem

Removableflashmedia

...................................................................................................................43

Omreport Chassis Slots Or Omreport Mainsystem Slots

............................................................ 44

Omreport Chassis Temps Or Omreport Mainsystem Temps

..................................................... 44

Omreport Chassis Volts Or Omreport Mainsystem Volts

............................................................45

Omreport Licenses

..............................................................................................................................45

Omreport System Commands Or Omreport Servermodule Commands

........................................46

Omreport System Or Omreport Servermodule

...........................................................................46

Commands For Viewing Logs

...................................................................................................... 46

Omreport System Alertaction Or Omreport Servermodule Alertaction

..................................... 47

Omreport System Assetinfo Or Omreport Servermodule Assetinfo

...........................................48

Omreport System Events Or Omreport Servermodule Events

................................................... 49

Omreport System Events Type Or Omreport Servermodule Events Type

.................................49

Omreport System Operatingsystem Or Omreport Servermodule Operatingsystem

................ 50

Omreport System Pedestinations Or Omreport Servermodule Pedestinations

......................... 51

Omreport System Platformevents Or Omreport Servermodule Platformevents

....................... 52

Omreport System Recovery Or Omreport Servermodule Recovery

.......................................... 52

Omreport System Shutdown Or Omreport Servermodule Shutdown

....................................... 53

Omreport System Summary Or Omreport Servermodule Summary

..........................................53

Omreport System Thrmshutdown Or Omreport Servermodule Thrmshutdown

......................58

Omreport System Version Or Omreport Servermodule Version

................................................ 58

Omreport Preferences Commands

....................................................................................................59

Omreport Preferences Messages

................................................................................................. 59

Omreport Preferences Webserver

................................................................................................59

4 Omconfig: Managing Components Using The Instrumentation

Service......................................................................................................................61

Conventions For Parameter Tables

.................................................................................................... 61

omconfig Command Summary

..........................................................................................................62

Help With The Omconfig Command

.................................................................................................64

Omconfig About

................................................................................................................................. 65

Omconfig Chassis Or Omconfig Mainsystem

................................................................................... 66

Omconfig Chassis Biossetup Or Omconfig Mainsystem Biossetup

........................................... 66

Omconfig Chassis Currents Or Omconfig Mainsystem Currents

...............................................83

Omconfig Chassis Fans Or Omconfig Mainsystem Fans

............................................................ 83

Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel

....................................... 84

Omconfig Chassis Info Or Omconfig Mainsystem Info

.............................................................. 85

Omconfig Chassis Leds Or Omconfig Mainsystem Leds

............................................................86

Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode

............................ 87

Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem Pwrmanagement

.................. 88

Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring

......................... 90

Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess

........................... 91

Omconfig Chassis Temps Or Omconfig Mainsystem Temps

...................................................102

Omconfig Chassis Volts Or Omconfig Mainsystem Volts

.........................................................103

Omconfig Preferences

......................................................................................................................103

Omconfig Preferences Cdvformat

............................................................................................. 103

Omconfig Preferences Dirservice

.............................................................................................. 104

Omconfig Preferences Messages

...............................................................................................104

Omconfig Preferences Useraccess

............................................................................................ 105

Omconfig Preferences Webserver

............................................................................................. 105

Omconfig System Or Omconfig Servermodule

.............................................................................. 106

Omconfig System Alertaction Or Omconfig Servermodule Alertaction

.................................. 106

Commands For Clearing Logs

.................................................................................................... 110

Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations

.......................111

Omconfig System Platformevents Or Omconfig Servermodule Platformevents

..................... 111

Omconfig System Events Or Omconfig Servermodule Events

................................................. 114

Omconfig System Webserver Or Omconfig Servermodule Webserver

....................................116

Omconfig System Recovery Or Omconfig Servermodule Recovery

........................................116

Omconfig System Shutdown Or Omconfig Servermodule Shutdown

..................................... 117

Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown

....................118

5 Omconfig System Or Servermodule Assetinfo: Editing Cost Of

Ownership Values................................................................................................ 119

Adding Acquisition Information

........................................................................................................ 119

Example Command For Adding Acquisition Information

.......................................................... 121

Adding Depreciation Information

..................................................................................................... 121

Example Command For Adding Depreciation Information

.......................................................122

Adding Extended Warranty Information

...........................................................................................122

Example Command For Adding Extended Warranty Information

.............................................123

Adding Lease Information

.................................................................................................................123

Example Command For Adding Lease Information

...................................................................124

Adding Maintenance Information

.....................................................................................................124

Example Command For Adding Maintenance Information

.......................................................125

Adding Outsource Information

.........................................................................................................125

Example Command For Adding Outsource Information

.......................................................... 126

Adding Owner Information

...............................................................................................................126

Example Command For Adding Owner Information

.................................................................127

Adding Service Contract Information

...............................................................................................127

Example Command For Adding Service Information

................................................................ 127

Adding Support Information

.............................................................................................................128

Example Command For Adding Support Information

...............................................................128

Adding System Information

.............................................................................................................. 129

Example Command For Adding System Information

................................................................ 129

Adding Warranty Information

........................................................................................................... 129

Example Command For Adding Warranty Information

.............................................................130

6 Using The Storage Management Service......................................................131

CLI Command Syntax

........................................................................................................................131

Syntax Of Command Elements

........................................................................................................ 132

User Privileges For Omreport Storage And Omconfig Storage

...................................................... 133

7 Omreport Storage Commands.......................................................................134

Omreport Physical Disk Status

..........................................................................................................135

omreport Virtual Disk Status

............................................................................................................. 136

Omreport Controller Status

..............................................................................................................136

Omreport Enclosure Status

...............................................................................................................137

Omreport Temperature Probe Status

.........................................................................................137

Omreport Fan Status

................................................................................................................... 138

Omreport Power Supply Status

.................................................................................................. 138

Omreport EMM Status

.................................................................................................................139

Omreport Enclosure Slot Occupancy Report

............................................................................140

Omreport Battery Status

...................................................................................................................140

Omreport Global Information

.......................................................................................................... 140

Omreport Connector Status

............................................................................................................. 141

Omreport Cachecade Status

............................................................................................................ 141

Omreport PCIe SSD Status

............................................................................................................... 142

Omreport Fluid Cache Status

........................................................................................................... 142

Omreport Fluid Cache Pool Status

...................................................................................................142

omreport Partition Status

..................................................................................................................143

Omreport Fluid Cache Disk Status

................................................................................................... 143

Omreport Storage Tape

....................................................................................................................143

8 Omconfig Storage Commands......................................................................144

Omconfig Physical Disk Commands

................................................................................................145

Omconfig Blink Physical Disk

..................................................................................................... 146

Omconfig Unblink Physical Disk

................................................................................................ 146

Omconfig Prepare To Remove Physical Disk

.............................................................................147

Omconfig Instant Erase Secured Physical Disk

..........................................................................147

Omconfig Cryptographic Erase Secured Physical Disk

.............................................................148

Omconfig Initialize Physical Disk

................................................................................................148

Omconfig Offline Physical Disk

..................................................................................................149

Omconfig Online Physical Disk

.................................................................................................. 149

Omconfig Assign Global Hot Spare

............................................................................................150

Omconfig Rebuild Physical Disk

.................................................................................................150

Omconfig Cancel Rebuild Physical Disk

.....................................................................................151

Omconfig Cancel Replace Member

........................................................................................... 151

Omconfig Clear Physical Disk

.....................................................................................................152

Omconfig Cancel Clear Physical Disk

........................................................................................ 152

Omconfig Enable Device Write Cache

.......................................................................................153

Omconfig Disable Device Write Cache

......................................................................................153

Omconfig Export Reliability Log

.................................................................................................154

Omconfig Convert RAID To Non-RAID

......................................................................................154

Omconfig Convert Non-RAID To RAID

......................................................................................155

Omconfig Virtual Disk Commands

...................................................................................................155

Omconfig Check Consistency

....................................................................................................156

Omconfig Cancel Check Consistency

....................................................................................... 157

Omconfig Pause Check Consistency

......................................................................................... 157

Omconfig Resume Check Consistency

..................................................................................... 158

Omconfig Blink Virtual Disk

........................................................................................................ 158

Omconfig Unblink Virtual Disk

................................................................................................... 158

Omconfig Initialize Virtual Disk

...................................................................................................159

Omconfig Fast Initialize Virtual Disk

........................................................................................... 159

Omconfig Slow Initialize Virtualize Disk

.....................................................................................159

Omconfig Cancel Initialize Virtual Disk

......................................................................................160

Omconfig Cancel Background Initialize

.................................................................................... 160

Omconfig Assign Dedicated Hot Spare

...................................................................................... 161

Omconfig Delete Virtual Disk

......................................................................................................161

Omconfig Format Virtual Disk

.................................................................................................... 162

Omconfig Reconfiguring Virtual Disks

....................................................................................... 162

Omconfig Secure Virtual Disk

.....................................................................................................163

Omconfig Clear Virtual Disk Bad Blocks

.................................................................................... 163

Omconfig Change Virtual Disk Policy

........................................................................................ 164

Omconfig Replace Member Virtual Disk

....................................................................................164

Omconfig Rename Virtual Disk

.................................................................................................. 165

Omconfig Enable Fluid Cache on Virtual Disk

........................................................................... 165

Omconfig Disable Fluid Cache on Virtual Disk

.......................................................................... 165

Omconfig Reactivate Fluid Cache on Virtual Disk

.....................................................................166

Omconfig Controller Commands

.................................................................................................... 166

Omconfig Rescan Controller

......................................................................................................168

Omconfig Enable Controller Alarm

............................................................................................168

Omconfig Disable Controller Alarm

...........................................................................................169

Omconfig Quiet Controller Alarm

..............................................................................................169

omconfig Test Controller Alarm

.................................................................................................169

Omconfig Reset Controller Configuration

.................................................................................170

omconfig Create Virtual Disk

......................................................................................................170

Omconfig Set Controller Rebuild Rate

....................................................................................... 177

omconfig Change Controller Properties

....................................................................................178

Omconfig Discard Preserved Cache

.......................................................................................... 178

Omconfig Create Encryption Key

...............................................................................................179

Omconfig Change Encryption Key

.............................................................................................179

Omconfig Delete Encryption Key

............................................................................................... 179

Omconfig Set Background Initialization Rate

............................................................................180

Omconfig Set Reconstruct Rate

.................................................................................................180

Omconfig Set Check Consistency Rate

.....................................................................................180

Omconfig Export The Controller Log

.........................................................................................181

Omconfig Import Secure Foreign Configuration

.......................................................................181

Omconfig Import Foreign Configuration

................................................................................... 181

Omconfig Import Or Recover Foreign Configuration

...............................................................182

Omconfig Clear Foreign Configuration

..................................................................................... 182

Omconfig Physical Disk Power Management

............................................................................182

Omconfig Set Patrol Read Mode

................................................................................................183

Omconfig Start Patrol Read

........................................................................................................ 183

Omconfig Stop Patrol Read

........................................................................................................ 183

Omconfig Create Cachecade

.....................................................................................................184

Omconfig Enable LKM Controller

.............................................................................................. 184

Omconfig Rekey LKM Controller

............................................................................................... 184

Omconfig Convert Multiple RAID To Non-RAID

....................................................................... 185

Omconfig Convert Multiple Non-RAID To RAID

....................................................................... 185

Omconfig Enclosure Commands

.....................................................................................................185

Omconfig Enable Enclosure Alarm

............................................................................................ 186

Omconfig Disable Enclosure Alarm

........................................................................................... 186

Omconfig Set Enclosure Asset Tag

............................................................................................ 187

Omconfig Set Enclosure Asset Name

.........................................................................................187

Omconfig Set Temperature Probe Thresholds

..........................................................................187

Omconfig Reset Temperature Probe Thresholds

......................................................................188

Omconfig Set All Temperature Probe Thresholds

.....................................................................188

Omconfig Reset All Temperature Probe Thresholds

.................................................................189

Omconfig Blink

............................................................................................................................189

Omconfig Battery Commands

......................................................................................................... 190 omconfig Start Battery Learn Cycle

........................................................................................... 190

Omconfig Delay Battery Learn Cycle

.........................................................................................190

Omconfig Global Commands

...........................................................................................................191

Omconfig Global Enable Smart Thermal Shutdown

..................................................................191

Omconfig Global Disable Smart Thermal Shutdown

.................................................................191

Omconfig Global Rescan Controller

..........................................................................................192

Omconfig Set Hot Spare Protection Policy

................................................................................192

Omconfig Connector Commands

................................................................................................... 193

Omconfig Rescan Connector

.....................................................................................................193

Omconfig Cachecade Commands

.................................................................................................. 193

Omconfig Blink Cachecade

........................................................................................................194

Omconfig Unblink Cachecade

................................................................................................... 194

Omconfig Delete Cachecade

.....................................................................................................194

Omconfig Resize Cachecade

..................................................................................................... 195

Omconfig Rename Cachecade

.................................................................................................. 195

Omconfig PCIe SSD Commands

......................................................................................................195

omconfig Add PCIe SSD Device To Cachepool

........................................................................ 196

Omconfig Add PCIe SSD Device To Cachepool

........................................................................196

Omconfig Reactivate PCIe SSD Device

......................................................................................196

Omconfig Fluid Cache Commands

..................................................................................................197

Omconfig Applying Or Updating License To The Fluid Cache

................................................. 197

Omconfig Conecting To The Fluid Cache

................................................................................. 197

Omconfig Partition Command

.........................................................................................................197

Omconfig Refreshing Partition List

............................................................................................ 198

Omconfig Fluid Cache Disk Command

........................................................................................... 198

Omconfig Discarding Data And Disabling Caching

...................................................................198

9 Working With CLI Command Results........................................................... 199

Output Options For Command Results

........................................................................................... 199

Controlling Command Output Display

............................................................................................199

Writing Command Output To A File

................................................................................................200

Saving Command Results To A File That Is Overwritten

...........................................................200

Append Command Results To An Existing File

..........................................................................201

Selecting A Format For The CLI Command Output

........................................................................202

List (lst)

.........................................................................................................................................203

Table (tbl)

.....................................................................................................................................203

Semicolon-Separated Values (ssv)

............................................................................................. 203

Custom Delimited Format (cdv)

.................................................................................................204

10

1

Introduction

Dell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution through either an integrated Web browser-based graphical user interface (GUI) or a command line interface (CLI). Server Administrator is designed for system administrators to manage systems locally and remotely on a network. It allows system administrators to manage their entire network by providing a comprehensive one-to-one systems management.

In the context of Server Administrator, a system refers to a stand-alone system, a system with attached network storage units in a separate chassis, or a Blade system consisting of one or more server modules in a modular enclosure.

Server Administrator provides easy-to-use management and administration of local and remote systems through a comprehensive set of integrated management services. Server Administrator is the sole installation on the system being managed and is accessible both locally and remotely from the Server

Administrator home page. Server Administrator enables you to access remotely monitored systems by dial-in, LAN, or wireless connections.

The configuration features enable Server Administrator to perform essential tasks described in detail in the following sections. This CLI guide documents all the commands that apply to Server Administrator and Storage Management.

The reporting and viewing features enable retrieval of the overall health status for systems on the network. You can view information about voltage, temperature, fan's revolutions per minute (RPM), memory functioning, and many other critical details at the component level. You can also see a detailed account of the cost of ownership (COO) about the system, retrieve version information about the BIOS, firmware, operating system, and all installed software.

NOTE: The CLI does not use the Server Administrator Web server. For concerns on encryption, from the CLI, run the omconfig system webserver action=stop command to turn off the Web server. The

Web server starts automatically after a reboot, so you must run this command each time the system

is rebooted. . For more information, see omconfig system webserver or omconfig servermodule webserver .

NOTE: After installing Dell OpenManage Server Administrator, ensure that you log out and log in to reset the path to access Dell OpenManage CLI utilities.

NOTE: For information on terms used in this document, see the Glossary at dell.com/support/ manuals.

What's New In This Release

The release highlights of OpenManage Server Administrator are:

• Added support for the following operating system:

– Microsoft Windows Server 2012 R2 Datacenter, Foundation, Essentials, and Standard editions

– Novell SUSE Linux Enterprise Server 11 SP3 (64–bit)

– Red Hat Enterprise Linux 6.5 (64–bit)

– VMware ESXi 5.0 U3 and ESXi 5.1 U2

– VMware vSphere 5.5

• Added support for the following browsers:

– Mozilla Firefox 22 and 23

– Internet Explorer 11

– Safari 6.0

– Google Chrome 27, 28, and 30

• Support for a new license format for Citrix XenServer 6.1.

• Added support for the following Adapter cards:

– Mellanox ConnectX-3 Dual Port 40 GbE QSFP+ Network Adapter

– Mellanox ConnectX-3 Dual Port 10 GbE DA/SFP+ Network Adapter

– Mellanox ConnectX-3 Dual Port 10 GbE KR Blade Mezzanine Card

– Emulex OCe14102-UX-D Dual Port 10Gb SFP+ CNA

– Emulex OCm14102-U3-D Dual Port 10Gb KR Blade Mezz

– Emulex OCm14102-U2-D Dual Port 10Gb KR Blade NDC

– Emulex OCm14104-UX-D Quad Port 10Gb DA/SFP+ Rack NDC

• Added support for Dell PERC 9 controllers (H730P Adapter) on R920 with the following features:

– RAID 10 virtual disk with uneven span.

– Advanced 4K sector hard disk drives.

– T10 Protection Information (PI) for data integrity.

NOTE: For more information, see the Server Administrator Storage Management guide at dell.com/openmanagemanuals.

• Support for displaying and setting the JRE version. See

Omreport Preferences Commands and

Omconfig Preferences Webserver

.

• Support for displaying Node Id in System/Server Module Summary information. See omreport system summary or omreport servermodule summary .

• Support for new values for form factor aligning to iDRAC values. See omreport system summary or omreport servermodule summary .

• Added support for Software RAID controllers (PERC S110) on systems running the Windows Server

2012 R2 operating system.

• Added support for Non-Volatile Memory Express (NVMe) Peripheral Component Interconnect Express

(PCIe) solid-state drives (SSDs). See the Server Administrator Storage Management guide at dell.com/ openmanagemanuals.

NOTE: Dell PowerEdge Express Flash NVMe PCIe SSD devices support only the Dell-provided

Windows Server 2012 R2 (64–bit) drivers.

• Added support for the following LSI Serial Attached SCSI (SAS) Host Bus Adapters (HBAs) on supported

12G systems:

– LSI SAS 9207–8e

11

– LSI SAS 9300–8e

– LSI SAS 9206–16e

• Added support for the following Dell PowerEdge servers:

– R920

– R220

– M820VRTX

• Deprecated support for the following operating systems:

– SUSE Linux Enterprise Server 10 SP4

– SUSE Linux Enterprise Server 11 SP2

– Red Hat Enterprise Linux 6.4 (64–bit)

– VMware ESXi 5.1 U1 HDD and Flash

– VMware ESXi 5.0 U2 HDD and Flash

NOTE: For the list of supported operating systems and Dell servers, see the Dell Systems Software

Support Matrix in the required version of OpenManage Software at dell.com/openmanagemanuals.

NOTE: CLI commands are not supported on systems running the VMware ESXi operating system.

Accessing The Windows Command Prompt To Run CLI

Commands

If you are running the Microsoft Windows operating system, use the 32-bit command prompt to run a

Server Administrator CLI command. Access the 32-bit command prompt using one of the following methods:

• Click Start → Programs → Accessories → Command Prompt.

• Click Start → Run and type cmd.exe.

NOTE: Do not type command in the Run dialog box to launch a command line window; this activates the MS-DOS emulator command.com, which has environment variable limitations that can cause subtle problems with CLI.

Primary CLI Commands

The commands that carry out the functions of Server Administrator are:

• omconfig

• omhelp

• omreport

The omconfig command writes values that you assign to an object's properties. You can specify values for warning thresholds on components or prescribe actions that the system must perform when a certain warning or failure event occurs. You can also use the omconfig command to assign specific values to the system's asset information parameters, such as the purchase price of the system, the system's asset tag, or the system's location.

12

The omhelp command displays short-text help for CLI commands. The shorthand equivalent of omhelp is the command for which you want help followed by -?. For example, to display help for the omreport command, type one of the following commands:

• omhelp omreport

• omreport -?

The omreport command displays reports of the management information of the system.

NOTE: For an overall summary of the CLI commands, type omhelp.

NOTE: The omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or the Server Update Utility commands. To update the different components, download the Dell Update Package and run the <package name> /s [/f command. For more information on the corresponding CLI syntax, see the Dell Update Packages

for Operating Systems User’s Guide or the Dell OpenManage Server Update Utility User’s Guide at dell.com/support/manuals.

Related Links: Working With CLI Command Results

CLI Error Checking And Error Messages

When you type CLI commands, the CLI checks these commands for the correct syntax. If you type a command and the command is executed successfully, a message is displayed, stating that the command is successful.

Success Messages

When you type a successful omconfig command, data for that component is displayed.

The following omconfig command examples displays valid CLI commands and their success messages:

Table 1. Commands And Messages

Command omconfig chassis temps index=0 warnthresh= default omconfig chassis biossetup attribute=numlock setting=on omconfig system assetinfo info=depreciation duration=6

Message

Temperature probe warning threshold value(s) set successfully.

BIOS setup configured successfully.

Change will take effect after the next reboot.

omconfig system assetinfo info=depreciation duration=6

NOTE: Due to limitations, some commands do not alter the system settings even though the commands are executed successfully. This is an expected behavior.

Failure Messages

CLI failure messages provide reasons why some commands do not succeed. Some common reasons why commands fail include syntax errors and components that are not present. Many error messages provide syntax information required to execute the command successfully.

13

If you execute a command for a component or feature that is not present in the system configuration, the error message states that the component is not present.

The following are examples of some failure messages:

Command

Message omconfig chassis volts index=3 minwarnthresh=3.3000

Error! Number with up to 3 digits after decimal point expected, read 3.3000

The value given by the command specifies more than 3 digits after the decimal point. A valid minimum warning threshold value for volts contains up to 3 digits after the decimal point.

Revised command omconfig chassis volts index=3 minwarnthresh=3.300

When you type the revised command with three decimal points, you receive another error message:

Message Error! This voltage probe min warning threshold must be between 11.400 and 12.480.

Revised command omconfig chassis volts index=3 minwarnthresh=11.500

Message

Voltage probe warning threshold(s) set successfully.

Scripting And Comparing Using CLI

The Server Administrator CLI allows administrators to write batch programs for the operating system. For an enterprise with many systems, an administrator could write a configuration script that specifies the warning thresholds for each major component of a system and also specifies a set of actions that the administrator wants each system to take in case of a warning or failure event. In most critical cases, the administrator could write a script so that the system shuts down to prevent damage. The administrator could then distribute and execute the script to many managed systems at the same time. Such a scenario facilitates configuring any number of new systems acquired by a company and makes implementation of new system administration policies easier across many existing systems that require re-configuration.

A similar scenario is used to populate a large number of newly acquired systems with detailed asset information. Much of the information are the same, such as the manufacturer or lessor of the system, whether support for the system is outsourced, name of the company providing insurance for the system, method of depreciation, and so on. Any variable that is common to all systems is scripted, sent to all managed systems, and executed. Asset information that is unique to a system is scripted as a group and sent to that managed node for execution. For example, a script could specify values for all unique variables such as the owner, primary user phone number, asset tag, and so on. Scripts to populate unique values would set all unique variables at once rather than one by one through the system's command line.

In many cases, the CLI allows a user with a very well-defined task in mind to retrieve information about the system rapidly. If a user wants to review a comprehensive summary of all system components and save that summary information to a file for comparison with later system states, the CLI is ideal.

Using CLI commands, administrators can write batch programs or scripts to execute at specific times.

When these programs are executed, they can capture reports on components of interest, such as fan

RPMs during periods of highest system usage compared with the same measurements at times of lowest system usage. Command results are routed to a file for later analysis. Reports can help administrators

14

gain information that are used to adjust usage patterns, to justify purchasing new system resources, or to focus on the health of a problem component.

Command Syntax Overview

Commands vary in complexity. The simplest command has only command level 1. The omhelp command is a simple command. When you type omhelp, a list of the main CLI commands is displayed.

The next level of complexity includes commands that contain command levels 1 and 2. All of the about commands are examples of command level 2 complexity. The omconfig about and omreport about commands display a very brief summary. The summary shows version information for the systems management software installed on the system; for example, Server Administrator 1.x.

Some commands have command level 1 and command level 2 and one name=value pair. Consider the following example command that instructs Server Administrator for more details about the environment for Server Administrator: omreport about details=true

In this example, command level 1 is omreport, command level 2 is about, and the name= value pair is details=true.

Many commands use command level 1, command level 2, and command level 3, but do not require any parameters (name=value pairs). Most omreport commands are of this type. For example, the following command displays a list of alert actions that are configured for components on a system.

omreport system alertaction

The most complex commands have all three command levels and can have multiple name=value pairs.

The following is an example of two name=value pairs: omconfig system assetinfo info=depreciation duration=3

The following is an example of nine name=value pairs: omconfig system assetinfo info=acquisition purchasecost=<n> waybill=<n> installdate=<mmddyy> purchasedate=<mmddyy> ponum=<n> signauth=<text> expensed=<yes>|no> costcenter=<text>

In each chapter of this document, command syntax and other information about the commands are formatted using any of the following fields as appropriate: command level 1 command level 2 command level 3 name=value pair 1 name=value pair 2

15

16

2

Using The omhelp Command

The omhelp command and its equivalent, <command> -?, accesses the detailed help-text interface of

Command Line Interface (CLI). You can get help at several levels of detail.

Each fully-qualified CLI command may have a variable number of distinct parts: the command

(command level 1), one or more subcommands (command level 2 and command level 3, if present), and one or more name= value pair(s).

By appending -?(space-dash-question mark) to any command, you can get help for that command.

Example Help Commands

When you type omconfig -?, you get general help about the omconfig command. The help at this level lists the available subcommands for omconfig:

• about

• preferences

• chassis

• system

When you type omconfig system -?, the CLI help lists all the subcommands available for omconfig system:

• alertaction

• alertlog

• assetinfo

• cmdlog

• esmlog

• events

• platformevents

• pedestinations

• recovery

• shutdown

• thrmshutdown

• webserver

Also parse the omconfig system assetinfo command as follows:

<command level 1 command level 2 command level 3> <name=value pair 1>

[name=value pair 2]

where command levels 1, 2, and 3 are represented by omconfig system assetinfo, name=value pair 1 is represented by info=depreciation , and name=value pair 2 is represented by method=straightline.

To set the depreciation method to straight line, type: omconfig system assetinfo info=depreciation method=straightline

The CLI responds with the following message:

Asset information set successfully.

When you type omconfig system assetinfo -?, the help that displays provides information about assigning values for the name and option fields. Partial results for the request omconfig system assetinfo

-? are as follows: assetinfo Set asset information.

For one info value, specify one or more optional parameter(s).

The following table displays the optional parameters for info=acquisition:

Table 2. Optional Parameters

Info Value

Info=acquisition

Optional parameters purchasecost=<num> waybill <num>installdate

=<mmddyy> purchasedate=<mmddyy> ponum=<num> signauth=<text> expensed=<yes|

no> costcenter=<text> info=depreciation method=<text> duration= <num> percent=<percent> unit=<months | years |

unknown>

17

18

omreport: Viewing System Status Using

The Instrumentation Service

3

The omreport command allows you to see detailed information about the system components. You can also retrieve summaries for many system components at one time, or get details about a specific component. This chapter shows you how to get reports with the level of detail that you want.

Commands documented in this chapter vary in whether they define the fields that appear in the results of a particular omreport command. The fields are defined only if they have a special or less familiar use.

As with all other components, use omreport to view component status, and omconfig to manage a

component. For information on configuring components for management, see omconfig: Managing

Components Using The Instrumentation Service

.

Use the omreport commands to get information you need to execute an omconfig command. For example, to edit the minimum temperature for a warning event on a temperature probe, you must know the index of the probe you want to configure. Use omreport chassis temps to display a list of probes and their indexes.

The omreport commands available on the system depend on the system configuration. The following table lists the systems on which the omreport commands are applicable:

Table 3. System Availability For The omreport Command

Command

Level 1 omreport

Command

Level 2 modularenclos ure

Applicable To servermodule Blade systems mainsystem Blade systems system chassis preferences

Blade systems

Rack and Tower systems

Rack and Tower systems

Blade or Rack, and Tower systems

Conventions For Parameter Tables

When listing the parameters that a command can take, the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface.

The symbol |, often called pipe, is the logical exclusive or operator. For example, enable | disable means you can enable or disable the component or feature, but you cannot simultaneously enable and disable the component or feature.

Command Summary Of The omreport Command

Depending on the system configuration, the results of the omreport command vary from one system to another. Data displays for installed components only.

NOTE: When a system includes an external chassis, the displayed results vary by operating system.

On SUSE Linux Enterprise Server and Red Hat Enterprise Linux systems, the omreport commands display external chassis information in a separate section after the main chassis information. On

Microsoft Windows systems, data about the external chassis does not appear in the omreport output.

The following table provides a high-level summary of the omreport command. The column titled

Command level 1 displays the omreport command at its most general use. Command level 2 shows the major objects or components that you can view using omreport (about, chassis, storage, and system).

Command level 3 lists the specific objects and components to view reports. User privilege required refers to the type of privilege you need to run the command, where U = User, P = Power User, and A =

Administrator. Use is a very general statement about the actions performed using omreport.

The following table lists the omreport commands available for about, system, and main system chassis.

Table 4. Command Level 1, Level 2, And Level 3 For omreport

Command

Level 1 omreport

Command Level

2

Command

Level 3

User

Privilege

Required

U, P, A

Use modularenclosu re about chassis or mainsystem details=true acswitch batteries bios biossetup fans

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

A

U, P, A

Displays the information for all the modular chassis.

Displays the version number and properties for Server Administrator.

Displays the information for all the Server

Administrator programs installed.

Displays the general status of all the main components.

Displays the failover settings where redundant AC power lines are supported in a system.

Displays the properties set for batteries.

Displays the BIOS information such as manufacturer, version, and release date.

Displays the BIOS setup properties configured during system boot.

Displays the status and thresholds for system fans.

19

Command

Level 1

Command Level

2

Command

Level 3 firmware frontpanel fru hwperforman ce info intrusion leds memory nics ports processors pwrmanagem ent

User

Privilege

Required

U, P, A

Use

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A pwrmonitorin g

U, P, A pwrsupplies U, P, A

Displays the name and version of the firmware.

Displays whether the front panel button settings, such as the Power button and/or

Nonmasking Interrupt (NMI) button (if present on the system), are enabled or disabled. It also displays the front panel encryption access information and the front panel LCD information.

Displays the Field Replaceable Unit (FRU) information.

Displays the status and cause for the system’s performance degradation.

Displays a status summary for main system chassis components.

Displays the status of the system’s intrusion sensor(s).

Displays the properties you have set for light-emitting diodes to flash under various alert conditions.

Displays properties of the system's memory arrays.

Displays the NIC and Team interface properties.

Displays the properties for the system’s parallel and serial ports, such as I/O address, IRQ level, connector type, and maximum speed.

Displays properties of the system’s processors, including speed, manufacturer, and processor family.

Displays power inventory details such as system idle power, system maximum potential power, and power budget information.

Displays properties of power consumption.

Displays the properties of power supplies.

20

Command

Level 1

Command Level

2

Command

Level 3

User

Privilege

Required remoteaccess U, P, A

Use licenses storage system or servermodule slots temps volts removableflas hmedia alertaction alertlog assetinfo cmdlog esmlog events operatingsyst em pedestination s

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A

U, P, A platformevent s

U, P, A

Displays general information on remote access.

Displays the properties of the system’s expansion slots and other slot types.

Displays the status and thresholds for the system temperature sensors.

Displays the status and thresholds for the system voltage sensors.

Displays the system’s virtual flash (vFlash) and secure digital (SD) card details.

Displays the digital licenses of the installed hardware devices of the system.

See

Using The Storage Management

Service

.

Displays a high-level summary of system components.

Displays the warning and failure threshold values, as well as actions configured when an essential component detects a warning or failure state.

Allows the administrator to display the alert log.

Displays the cost of ownership information for the system.

Allows the administrator to display the command log.

Allows the administrator to display the hardware log.

Displays the system’s Simple Network

Management Protocol (SNMP) event settings.

Displays the name and version of the operating system.

Displays the destinations to send the configured alerts for platform events.

Displays the system’s response for each listed platform event

21

Command

Level 1

Command Level

2 preferences

Command

Level 3 recovery shutdown summary thrmshutdow n version webserver messages

User

Privilege

Required

P, A

Use

P, A

U, P, A

P, A

U, P, A

U, P, A

A

Displays how the system is configured to respond to a hung operating system.

Displays how to perform the shutdown action.

Displays the key facts for all system components, including main system chassis, software, and storage.

Displays how to perform the shutdown action, if any, when a temperature warning or failure condition is detected.

Displays a summary for all updatable components on the system.

Displays the URL information of the Server

Administrator Web server.

Displays the configured alert message format.

Related Links: omreport: Viewing System Status Using The Instrumentation Service

Help With The omreport Command

Use the omreport -? command to get a list of the available commands for omreport.

Use omreport <command level 2> -? to get help on the level 2 about, chassis, and system commands.

The following information on omreport system -? also applies to get help for the omreport chassis command.

To see a list of valid commands for omreport system, type: omreport system -? | more

omreport modularenclosure

Use the omreport modularenclosure command to view details of the Blade system. Type: omreport modularenclosure

NOTE: This CLI command is available when Dell OpenManage Server Administrator is installed on

Dell Blade systems.

Server Administrator displays information related to the modular enclosure and chassis management controller CMC (if available):

NOTE: The output varies depending on the configuration of the system.

22

Modular Chassis Information

Chassis Information

Attribute

Value

Attribute

Value

Attribute

Value

Attribute

Value

CMC Information

Attribute

Value

Attribute

Value

: Model

: Modular Server Enclosure

: Lock

: true

: Service Tag

: 8RLNB1S

: Express Service Code

: 18955029124

Attribute

Value

Attribute

Value

Attribute

Value

Attribute

Value

Attribute

Value

: Product

: Chassis Management Controller (CMC)

: Description

: The system component provides a complete set of remote managementfunctions for Dell systems.

: Version

: 3.20

: IP Address

: 101.102.103.104

: IP Address Source

: Dynamic Source

: IP Address Type

: IPv4

: Remote Connect Interface

: Launch CMC Web Interface

omreport about

Use the omreport about command to learn the product name and version number of the systems management application installed on the system. The following is an example output from the omreport about command:

Product name

Version

: Dell OpenManage Server Administrator

: x.x.x

23

Copyright

Company

: Copyright (C) Dell Inc. xxxx-xxxx. All rights reserved.

: Dell Inc.

For details about the environment for Server Administrator, type: omreport about details=true

Server Administrator includes a number of services, each of which has a version number of its own. The

Contains field reports version numbers for the services as well as other useful details. The following output is an example, and can change depending on the system’s configuration and the version of Server

Administrator installed on the system:

Contains:

Instrumentation Service 7.x.x

Storage Management 4.x.x

Sun Java Runtime Environment 1.x.x_xx

Secure Port Server 7.x.x

Server Administrator Core Files 7.x.x

Instrumentation Service Integration Layer 7.x.x

Server Administrator Common Framework 7.x.x

Common Storage Module 4.x.x

Data Engine 7.x.x

Instrumentation Service 7.x.x

Omreport Chassis Or Omreport Mainsystem Commands

Use the omreport chassis or omreport mainsystem commands to view details for the entire chassis or for a particular component. Type: omreport chassis or omreport mainsystem

Server Administrator displays a general status for the main system chassis or main system components.

Health

Main System Chassis

SEVERITY

Ok

Critical

Ok

Ok

Ok

Ok

: COMPONENT

: Fans

: Intrusion

: Memory

: Power Supplies

: Temperatures

: Voltages

24

Omreport Chassis Acswitch Or Omreport Mainsystem Acswitch

Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that are configured in a failover arrangement. Type: omreport chassis acswitch or omreport mainsystem acswitch

Server Administrator displays the following output:

AC Failover Switch

AC Switch Redundancy

Redundancy Status

Number of devices required for full redundancy

Redundancy Mode

Redundancy Configuration

: Full

: 2

:

: Input Source Line 1, upon redundancy restoration, return to Line 1

AC Power Lines

Status

Location

AC Present

Active Source

Status

Location

AC Present

Active Source

: Ok

: AC Power Line 1

: Power Present

: Active

: Ok

: AC Power Line 2

: Power Present

: Not Active

Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.

Omreport Chassis Batteries Or Omreport Mainsystem Batteries

Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties. Type: omreport chassis batteries or omreport mainsystem batteries

25

Omreport Chassis Bios Or Omreport Mainsystem Bios

Use the omreport chassis bios or omreport mainsystem bios command to view the current BIOS information. Type: omreport chassis bios or omreport mainsystem bios

Server Administrator displays the summary of the BIOS information for the system.

Omreport Chassis Biossetup Or Omreport Mainsystem Biossetup

Use the omreport chassis biossetup or omreport mainsystem biossetup command to view BIOS setup parameters that are normally available only during system boot. Type: omreport chassis biossetup or omreport mainsystem biossetup

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

To view the BIOS Setup parameters in short form, type: omreport chassis biossetup display=shortnames

To view all available boot devices, alias names, and boot order sequences, type: omreport chassis biossetup attribute=bootorder

NOTE: The bootorder attribute is applicable only on systems prior to 12G. To list the device boot order, type omreport chassis biossetup and serach the list under BIOS Boot Settings or UEFI

Boot Settings depending on the BIOS boot setting.

NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot view the boot order sequence.

BIOS Setup Parameters On Systems Prior To PowerEdge 12G Systems

The following table displays the available BIOS setup parameters on systems prior to PowerEdge 12G systems.

NOTE: All the BIOS Setup parameters are not displayed. Only those BIOS setup properties configured during system boot are displayed.

Table 5. BIOS Setup Parameters On Systems Prior To Dell PowerEdge 12G Systems

Parameter

Bootsequence

Numlock

Embedded Video

Controller

Description

Displays the device used to boot the system.

Displays whether the keypad is used as number keys.

Displays whether the Embedded Video Controller option is enabled or disabled.

26

Parameter

Boot Mode

Description

Displays whether the boot mode is configured to BIOS or Unified

Extensible Firmware Interface (UEFI).

Processor C1-E

CPU Execute Disable

Displays the Processor C1-E status.

Displays whether the Execute Disable (XD) option is enabled or disabled.

Processor C State Control Displays whether the Processor C State Control option is enabled or disabled.

Processor CMP Displays the number of cores enabled per processor.

User accessible USB Ports Displays whether the user-accessible USB port is enabled or disabled.

CPU Virtualization

Technology

Displays the additional hardware capabilities provided by Virtualization

Technology.

AC Power Recovery Mode Displays the system state when input power is restored after an outage.

Embedded SATA Controller Displays whether the embedded SATA controller is set to ATA mode, RAID mode, or is disabled.

SATA Port 0

SATA Port 1

Displays the state of SATA port 0.

Displays the state of SATA port 1.

Dual NIC (1/2)

Dual NIC (3/4)

NIC 1

NIC 2

Displays whether NIC 1 and NIC 2 with PXE/iSCSI is enabled or disabled.

Displays whether NIC 3 and NIC 4 with PXE/iSCSI is enabled or disabled.

Displays whether the first NIC is enabled (with or without PXE/iSCSI) or disabled during system boot.

Displays whether the second NIC is enabled (with or without PXE/iSCSI) or disabled during system boot.

NIC 3

NIC 4

Displays whether the third NIC is enabled (with or without PXE/iSCSI) or disabled during system boot.

Displays whether the fourth NIC is enabled (with or without PXE/iSCSI) or disabled during system boot.

Displays whether TCM is on or off.

Trusted Cryptographic

Module (TCM)

Trusted Platform Module

(TPM) Security

Displays whether TPM is off, on with pre-boot measurements, or on without pre-boot measurements.

Internal USB Port (number) Displays whether the internal USB is enabled or disabled.

NOTE: Server Administrator may not display the USB sequence number if there is only one USB port on the system.

Operating System

Watchdog Timer

HT Assist

Internal SD Card

Displays whether the operating system watchdog timer is enabled or disabled.

Displays the status of the probe filter chipset option.

Displays whether the internal SD card is enabled or disabled.

27

Parameter

Bezel

Console Redirection

Diskette

Demand Based Power

Management (DBS)

Embedded Hypervisor

IDE

IDE Primary Drive 0

IDE Primary Drive 1

Intrusion

Mouse

Optical Drive Controller

Parallel port address

Parallel port mode

Primary SCSI

RAID on motherboard

RAID Channel A

RAID Channel B

Serial Port 1

Serial Port 2

Speaker

USB or USBB

Secondary SCSI

Serial Communications

Description

Displays whether the bezel removal intrusion check during system reboot is enabled or disabled.

Displays whether the BIOS screen is redirected over a particular serial port or if it is turned off.

Displays whether the diskette is disabled, auto enabled, or read-only.

Displays whether DBS is enabled or disabled on the system.

Displays whether the embedded hypervisor is enabled or disabled.

Displays whether the drive is enabled or disabled.

Displays whether the device is automatically detected and enabled or if the device is disabled.

Displays whether the device is automatically detected and enabled or if the device is disabled.

Displays whether the intrusion check is enabled or disabled during system boot.

Displays whether the mouse is enabled or disabled.

Displays whether the optical drive controller is enabled or disabled.

Displays whether the address is located on LPT1, LPT2, and LPT3, or if it is disabled.

Displays the setting associated with the parallel port.

Displays whether the device is on or off.

Displays whether RAID-on-motherboard is detected as a RAID device, a

SCSI device, or if the device is disabled during system boot.

Displays whether RAID-on-motherboard Channel A is detected as a RAID device or a SCSI device.

Displays whether RAID-on-motherboard Channel B is detected as a RAID device or a SCSI device.

Displays whether serial port 1 is mapped to a COM port, COM port 1, COM port 3, COM1 BMC, BMC Serial, BMC NIC, BMC RAC, or is disabled.

Displays whether serial port 2 is mapped to a COM port, COM port 2, COM port 4, or is disabled.

Displays whether the speaker is on or off.

Displays whether the USB port is enabled or disabled.

Displays whether the device is enabled or disabled.

Displays whether COM port 1 and COM port 2 are off or on with or without console redirection.

28

Parameter

Console Redirection After

Boot

Description

Displays whether console redirection after system reboot is enabled or disabled.

External Serial Connector Displays whether the external serial connector is mapped to Serial Device

1, Serial Device 2, or a Remote Access Device.

Console Redirection

Failsafe Baud Rate

Displays the setting for console redirection failsafe baud rate.

Serial Address Select Displays port address for the serial devices.

BIOS Setup Groups On PowerEdge yx2x Systems

The following table lists the available groups of the BIOS setup parameters on PowerEdge yx2x systems.

NOTE: Based on the hardware configuration, the attributes may vary in a specific group.

Table 6. BIOS Setup Groups On PowerEdge yx2x Systems

Group

BIOS Boot Settings

Boot Settings

Embedded Server

Management

Integrated Devices

Memory Settings

Miscellaneous Settings

One-Time Boot

Processor Settings

SATA Settings

Serial Communication

Slot Disablement

System Information

System Profile Settings

System Security

UEFI Boot Settings

Description

Controls the system boot settings when bootmode is set to bios.

Controls the system boot settings when bootmode is set to bios.

Sets up the Embedded Server Management options.

Controls the devices integrated on the system board.

Controls the system memory settings.

Controls some miscellaneous system settings.

Supports one-time boot to a specified device.

Controls the processor(s) settings of the system.

Control the embedded SATA ports settings.

Controls the Serial Communication options.

Controls the system slots that are present on the system.

Displays the information that uniquely identifies the system.

Controls the power management settings.

Controls the security features of the system.

Controls the system boot settings when boot mode is set to uefi.

Omreport Chassis Currents Or Omreport Mainsystem Currents

This command is no longer available through Server Administrator.

29

Omreport Chassis Fans Or Omreport Mainsystem Fans

Use the omreport chassis fans or omreport mainsystem fans command to view the fan probe status and settings. Type: omreport chassis fans index=n or omreport mainsystem fans index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any fan probes that are present on the system. If you specify the index, Server Administrator displays a summary for a specific fan probe.

Omreport Chassis Firmware Or Omreport Mainsystem Firmware

Use the omreport chassis firmware or omreport mainsystem firmware command to view current firmware properties. When you type: omreport chassis firmware or omreport mainsystem firmware

Server Administrator displays a summary of the system’s firmware properties.

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server Administrator displays the Unified Server Configurator (USC) version.

Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel

Use the omreport chassis frontpanel or omreport mainsystem frontpanel command to view if the front panel button control settings, such as the Power button and/or Nonmasking Interrupt (NMI) button (if present on the system), are enabled or disabled.

If the Power button override is present on the system, check whether the Power button override is enabled or not. If enabled, the Power button turns the power to the system On and Off.

If the NMI button is present on the system, check whether the NMI button is enabled or not. Use the NMI button to troubleshoot software and device errors when using certain operating systems.

The Front Panel LCD Security Access displays if the front panel encryption access information is set to

View, Modify, or Disable.

The Front Panel LCD Information displays information such as service tag, remote indication status, and so on.

30

Omreport Chassis Fru Or Omreport Mainsystem Fru

Use the omreport chassis fru or omreport mainsystem fru command to view FRU information. When you type: omreport chassis fru or omreport mainsystem fru

Server Administrator displays a summary of the system’s FRU information. This information is available in the Server Administrator GUI, SNMP, and Common Information Model and is primarily used to support troubleshooting activities.

Omreport Chassis Hwperformance Or Omreport Mainsystem

Hwperformance

Use the omreport chassis hwperformance or omreport mainsystem hwperformance command to view the status and cause for the system’s performance degradation. When you type: omreport chassis hwperformance or omreport chassis hwperformance

Server Administrator displays a summary of the system’s hardware performance degradation information.

NOTE: This command is applicable only to selected Dell 10G systems that support PMBus.

Depending on the system’s configuration, you may notice the following output:

Hardware Performance

Index

Probe Name

: 0

: System Board Power Optimized

Status

Cause

: Normal

: [N/A]

Omreport Chassis Info Or Omreport Mainsystem Info

Use the omreport chassis info or omreport mainsystem info command to see a summary of installed component versions. Type: omreport chassis info index=n or omreport mainsystem info index=n

The index parameter specifies a chassis number and is optional. If you do not specify the index, Server

Administrator displays summary chassis information for each chassis. If you specify the index, Server

Administrator displays summary information for a specific chassis.

NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server Administrator displays the USC version.

31

Depending on the system’s configuration, you may notice the following output:

Index

Chassis Name

Host Name iDRAC7 Version

Chassis Model

Chassis Lock

Chassis Service Tag

Express Service Code

Chassis Asset Tag

: 0

: Main System Chassis

: WIN-27C02UQFV6L

: 1.00

: PowerEdge R720

: Present

: 7654321

: 15608862073

: c

Omreport Chassis Intrusion

Use the omreport chassis intrusion command to find out whether the cover of the system is open or not.

Server Administrator tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component, or to perform unauthorized maintenance on the system. Type: omreport chassis intrusion

A message that resembles the following is displayed:

Intrusion Information

Health

Index

Status

Probe Name

State

: Ok

: 0

: OK

: Intrusion

: Chassis is closed

Omreport Chassis Leds Or Omreport Mainsystem Leds

Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard drive fault is supported and what severity level lights up the LED. Type: omreport chassis leds index=n or omreport mainsystem leds index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of LED information for chassis 0. If you specify the index, Server Administrator displays a summary for a specific chassis.

The following is an example output:

32

Main System Chassis

Flash chassis identify LED state : Off

Flash chassis identify LED timeout value : 300

Omreport Chassis Memory Or Omreport Mainsystem Memory

Use the omreport chassis memory or omreport mainsystem memory to view details for each memory module slot in the system. If the system supports redundant memory, this command also displays the status, state, and type of memory redundancy implemented on the system. Type: omreport chassis memory index=n or omreport mainsystem index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays information for all memory modules on the system as follows:

The following is an example output:

Memory Information

: Ok Health

Attributes of Memory Array(s)

Location

Use

Installed Capacity

Maximum Capacity

Slots Available

Slots Used

Error Correction

Total of Memory Array(s)

Total Installed Capacity

Total Installed Capacity Available to the OS

Total Maximum Capacity

Details of Memory Array 1

Index

Status

Status

: System Board or Motherboard

: System memory

: 65536 MB

: 786432 MB

: 24

: 8

: Multibit ECC

: 65536 MB

: 64386 MB

: 786432 MB

: 0

: Ok

: Ok

33

Status

Connector Name

Type

Size

Index

Status

Connector Name

Type

Size

Index

Status

Connector Name

Type

Size

Index

Status

Connector Name

Type

: Ok

: DIMM_A1

: DDR3 - Synchronous Registered

(Buffered)

: 8192 MB

: 1

: Ok

: DIMM_A2

: DDR3 - Synchronous Registered

(Buffered)

: 8192 MB

: 2

: Ok

: DIMM_A3

: DDR3 - Synchronous Registered

(Buffered)

: 8192 MB

: 3

: Ok

: DIMM_A4

: DDR3 - Synchronous Registered

(Buffered)

: 8192 MB Size

If you specify the index, Server Administrator displays a summary for a specific memory module displaying the health, status, device name, type, speed, rank, and failures. A rank is a row of dynamic random access memory (DRAM) devices comprising 64 bits of data per Dual Inline Memory Module

(DIMM). The possible values of rank are single, dual, quad, octal, and hexa. The rank displays the rank of the DIMM and helps in the easy service of DIMMs on the server.

The following is an example output if you specify the index:

Memory Device Information

Health : Ok

Status

Device Name

: Ok

: DIMM_A1

34

Size

Type

Speed

Rank

Failures

: 8192 MB

: DDR3 Synchronous Registered (Buffered)

: 0.75 ns

: Dual

: None

NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. Change the user scripts as applicable.

Omreport Chassis Nics Or Omreport Mainsystem Nics

Use the omreport chassis nics or omreport mainsystem nics command to view NIC and Team interface details. On XenServer, the command displays all the installed NICs, regardless of driver installation.

NOTE: The order in which devices are detected is not guaranteed to match the physical port ordering of the device.

To view NIC properties, type: omreport chassis nics index=n or omreport chassis nics index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays properties of all NICs on the system and the values for the following fields: Index (NIC card number), Interface

Name, Vendor, Description, Connection Status, and Slot.

If you specify the index, Server Administrator displays properties for a specific NIC and the values for the following fields: Physical Interface, Interface name, IPv4 Addresses, IPv6 Addresses, Physical Interface

Receive Statistics, Physical Interface Transmit Statistics, Interface Receive Statistics, and Interface

Transmit Statistics.

NOTE: The Fibre Channel over Ethernet (FCoE) and iSCSI over Ethernet (iSoE) features of Converged

Network Adapter (CNA) cards are not supported on VMware ESX and VMware ESXi systems.

To view Team interface properties, type: omreport chassis nics config=team index=n or omreport mainsystem nics config=team index=n

NOTE: This command is applicable only if Team interface is configured in the system. Team interface is configured using NIC vendor tools, such as Broadcom.

The index parameter is optional. If you do not specify the index, Server Administrator displays details of all the Team interfaces on the system and the values for the following fields: Index (NIC card number),

Interface Name, Vendor, Description, and Redundancy Status.

If you specify the index, Server Administrator displays the Team interface details for the specific NIC and the values for the following fields: Team Interface, Interface, IPv4 Addresses, IPv6 Addresses , Team

35

Interface Receive Statistics , Team Interface Transmit Statistics , Interface Receive Statistics, and Interface

Transmit Statistics.

Omreport Chassis Ports Or omreport Mainsystem Ports

Use the omreport chassis ports or omreport mainsystem ports command to view properties of the system’s parallel and serial ports.

NOTE: CMC USB ports attached with blade servers are not enumerated by OMSA.

Server Administrator displays values for the following fields: Port Type, External Name, Base I/O Address,

IRQ Level, Connector Type, and Maximum Speed. The following table provides the description of the fields:

Table 7. Fields and Description

Field Description

Port Type Detailed type of each system port, from the more general serial, parallel, and USB ports to the names of ports by device type connected to it, for example, pointing device or keyboard.

Name of the port, such as serial or parallel, USB, mouse, keyboard, and so on.

External

Name

Base I/O

Address

Starting I/O address expressed in hexadecimal.

IRQ Level Hardware interrupt on a system. The hardware interrupt signals the system's CPU that an event has started or ended in a peripheral component such as a modem or printer. When communicated over a peripheral component interconnect card, the IRQ level is a standard way to identify the type of device that is sending the interrupt request.

Connector

Type

Type of plug or cable and plug that connects two devices together, in this case, the type of connector that attaches an external device to a system. There are many connector types, each designed to connect a different device type to a system. Examples include DB-9

Male, AT, Access Bus, PS/2, and so on.

Maximum

Speed

Port speed. Port speed refers to the data transmission rate of an input/output channel, measured in numbers of bits per second. Serial ports usually have a maximum speed of 115

Kbps and USB version 1.x ports have a maximum speed of 12 Kbps.

Omreport Chassis Processors Or Omreport Mainsystem Processors

Use the omreport chassis processors or omreport mainsystem processors command to view properties of the system’s processors.

Server Administrator displays values for the following fields: Index, Status, Connector Name, Processor

Brand, Processor Version, Current Speed, State, and Core Count.

The following table provides the description of the fields.

36

Table 8. Fields and Description

Field

Index

Status

Connector

Name

Description

Processor number

Current status of the processor.

Name or number of the device that occupies the processor slot in the system.

Processor Brand Type of processor made by a manufacturer such as Intel Itanium, Intel Pentium III,

Intel Xeon, or AMD Opteron.

Processor

Version

Model and stepping number of the processor.

Current Speed Actual processor speed in MHz at system boot time.

State Whether the processor slot is enabled or disabled.

Core Count Number of processors integrated into one chip.

Capabilities And Cache Properties Of A Specific Processor

To view the cache properties of a processor on a given connector, type: omreport chassis processors index=n or omreport mainsystem processors index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all processors. If you specify the index, Server Administrator displays properties for a specific processor.

The following table lists the fields that are defined for the capabilities present on a particular microprocessor:

Table 9. Microprocessors and Fields

Microprocessor

Intel Processor

Fields

• 64-bit Support

• Hyperthreading (HT)

• Virtualization Technology (VT)

• Demand-Based Switching (DBS)

• Execute Disable (XD)

• Turbo Mode

AMD Processor • 64-bit Support

• AMD-V

• AMD PowerNow!

• No Execute (NX)

The following fields are defined for a cache present on a particular microprocessor. If the cache is internal to the processor, the fields do not appear in the cache report:

37

• Speed

• Cache Device Supported Type

• Cache Device Current Type

• External Socket Name

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

The following table displays the fields that are displayed for each cache on a particular processor:

Table 10. Fields And Description

Field

Status

Level

Speed

Max Size

Installed Size

Type

Location

Write Policy

Description

Reports whether a specific cache on the processor is enabled or disabled.

Refers to a primary or secondary cache. Primary-level cache is a memory bank built into the processor. Secondary-level cache is a staging area that feeds the primary cache. A secondary-level cache is built into the processor or resides in a memory chipset outside the processor. The internal processor cache is referred to as a Level 1 (or

L1). L2 cache is the external cache in a system with an Intel Pentium processor, and it is the second level of cache that is accessed. The names L1 and L2 are not indicative of where the cache is physically located (internal or external), but describe which cache is accessed first

(L1, therefore internal).

Refers to the rate at which the cache can forward data from the main memory to the processor.

Maximum amount of memory that the cache can hold in kilobytes.

Actual size of the cache.

Indicates whether the cache is primary or secondary.

Location of the cache on the processor or on a chipset outside the processor.

Describes how the cache deals with a write cycle. In a write-back policy, the cache acts like a buffer. When the processor starts a write cycle, the cache receives the data and stops the cycle. The cache then writes the data back to the main memory when the system bus is available.

In a write-through policy, the processor writes through the cache to the main memory. The write cycle does not complete until the data is stored into the main memory.

Associativity

Refers to the way in which main memory content is stored on the cache.

• A fully associative cache allows any line in main memory to store at any location in the cache.

• A n-way set-associative cache directly maps n specific lines of memory to the same n lines of cache. For example, line 0 of any page in memory is stored in line 0 of cache memory.

38

Field

Cache Device Supported

Type

Cache Device Current Type

External Socket Name Silk

Screen Name

Error Correction Type

Description

Type of static random access memory (SRAM) that the device can support.

Type of the currently installed SRAM that the cache is supporting.

Name printed on the system board next to the socket.

Identifies the type of error checking and correction (ECC) that this memory can perform. Examples are correctable ECC or uncorrectable

ECC.

Omreport Chassis Pwrmanagement Or Omreport Mainsystem

Pwrmanagement

Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view the power budget cap and power management profiles of the system. The values display either in Watts or BTU/Hr based on the configuration. Type: omreport chassis pwrmanagement or omreport mainsystem pwrmanagement

NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.

NOTE: The omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command is applicable on PowerEdge 11G systems that support Power Management Bus (PMBus) and that have hot-swappable power supplies and not systems that have a fixed, non-redundant power supply installed.

The output of the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command lists each of the valid parameters. The following table lists the available settings.

Table 11. Valid Parameters Of Omreport Chassis Pwrmanagement Or Omreport Mainsystem

Pwrmanagement name=value pair unit=<watt | btuphr>

Description

Displays power in the user-specified units.

config=budget config=profile

Displays power budget information.

Displays power profiles information.

NOTE: On PowerEdge 12G systems, profile option is SysProfile and is grouped under

System Profile Settings of the BIOS setup group. For more information, see

BIOS Setup

Settings on PowerEdge 12G systems

.

39

For each power management profile in the system, values display for the following fields: Maximum

Performance, Active Power Controller, OS Control, and Custom.

The Custom attributes are: CPU Power and Performance Management, Memory Power and Performance

Management, and Fan Power and Performance Management.

The following is an example output:

Power Inventory and Budget

Power Inventory

System Idle Power

System Maximum Potential Power

: 92 W

: 344 W

Power Budget

Attribute

Values

Attribute

Values

: Enable Power Cap

: Enabled

: Power Cap

: 400 W (56%)

NOTE: Power budget requires license to report the details. If the appropriate license is not installed or has expired, the system does not display the power budget details. For more information, see the

Dell License Manager Guide at dell.com/support/manuals.

Omreport Chassis Pwrmonitoring Or Omreport Mainsystem Pwrmonitoring

Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the properties of the system’s power consumption. The values display either in Watts or BTU/Hr based on the configuration. Type: omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring

For each power monitoring profile in the system, values display for the following fields:

• Power Consumption Status

• Probe Name

• Reading

• Warning Threshold

• Failure Threshold

• Amperage: Location and Reading

• Power Tracking Statistics

• Energy Consumption

• Measurement Start Time

• Measurement Finish Time

40

• Reading

• System Peak Power

• System Peak Amperage

NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system onwards that support PMBus and that have hot-swappable power supplies and not systems that have a fixed, non-redundant power supply installed.

NOTE: Power monitoring requires license to report the details. If the appropriate license is not installed or has expired, the system does not display the power consumption details of the system.

For more information, see the Dell License Manager Guide at dell.com/openmanagemanuals.

NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.

An example output reporting power statistics in Watts is as follows:

Power Consumption Information

Power Consumption

Index

Status

Probe Name

Reading

Warning Threshold

Failure Threshold

Amperage

PS1 Current 1

Power Headroom

System Instantaneous Headroom

System Peak Headroom

Power Tracking Statistics

Statistic

Measurement Start Time

Measurement Finish Time

Reading

Statistics

Measurement Start Time

Peak Time

Peak Reading

: 1

: Ok

: System Board Pwr Consumption

: 539W

: 994W

: 1400 W

: 1.2 A

: 300 W

: 340 W

: Energy consumption

: Thu May 28 11:03:20 2011

: Fri May 28 11:05:46 2011

: 5.9 KWH

: System Peak Power

: Mon May 18 16:03:20 2011

: Wed May 27 00:23:46 2011

: 630 W

41

Statistics

Measured Since

Read Time

Peak Reading

: System Peak Amperage

: Mon May 18 16:03:20 2011

: Tue May 19 04:06:32 2011

: 2.5 A

NOTE: Power Management features are only available for PowerEdge systems that have hotswappable power supplies and not systems that have a fixed, non-redundant power supply installed.

Omreport Chassis Pwrsupplies Or Omreport Mainsystem Pwrsupplies

Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties of the system’s power supplies. Type: omreport chassis pwrsupplies or omreport mainsystem pwrsupplies

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

For each power supply profile in the system, the values for the following fields are displayed:

• Status

• Location

• Type

• Rated Input Wattage (in Watts)

• Maximum Output Wattage

• Online Status

• Power Monitoring Capable

Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess

Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information on baseboard management controller or integrated Dell remote access controller

(BMC/iDRAC) and remote access controller if DRAC is installed. Type: omreport chassis remoteaccess or omreport mainsystem remoteaccess

NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.

The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists each of the valid parameters as displayed in the following table:

42

Table 12. Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess name=value pair config=additional config=advsol config=nic config=serial config=serialoverla n config=terminalmo de config=user

Description

Reports the current state of IPv4 and IPv6 addresses on iDRAC.

Reports advanced BMC/iDRAC or remote access information on a serial over local area network (LAN) connection.

Reports BMC/iDRAC or remote access information for the LAN.

Reports serial port information for BMC or remote access.

Reports BMC/iDRAC or remote access information on a serial over LAN connection.

Reports terminal mode settings for the serial port.

Reports information on BMC/iDRAC or remote access users.

Omreport Chassis Removableflashmedia Or Omreport Mainsystem

Removableflashmedia

Use the omreport chassis removableflashmedia or omreport mainsystem removableflashmedia to view the removable flash media details on the system along with its health status. Type: omreport chassis removableflashmedia or omreport mainsystem removableflashmedia

Server Administrator displays a summary of the system’s removable flash media information.

NOTE: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.

Depending on the configuration of the system, you may notice the following output:

Removable Flash Media Information

Health

Internal Dual SD Module Redundancy

Attribute

Value

Internal SD Modules Status

Status

Connector Name

State

: Critical

: Critical

: Redundancy

: Lost

: OK

: System Board SD Status 1

: Present

Storage Size

Status

: 512 MB

: OK

43

Connector Name

State

Storage Size

VFlash Media Details

Connector Name

Type

State

Available Size

Storage Size

: System Board SD Status 2

: Present

: 512 MB

: System Board SD Status 1

: vFlash SD Card

: Present

: 472 MB

: 512 MB

Omreport Chassis Slots Or Omreport Mainsystem Slots

Use the omreport chassis slots or omreport mainsystem slots command to view properties of the system’s slots. Type: omreport chassis slots index=n or omreport mainsystem slots index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all of the slots in the system. If you specify the index, Server Administrator displays properties for a specific slot.

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

For each slot in the system, values display for the following fields given in the following table:

Table 13. Valid Parameters Of Omreport Chassis Slots Or Omreport Mainsystem Slots

Field

Index

Slot ID

Adapter

Data Bus

Width

Description

Number of the slot in the system.

Silk screen name printed on the system's motherboard next to the slot. Alphanumeric text uniquely identifies each slot in the system.

Name and/or type of the card that fits into the slot, for example, a storage array controller,

SCSI adapter, iDRAC Enterprise, or HBA.

Width, in bits, of the information pathway between the components of a system. The range of the data bus width is from 16 to 64 bits.

Omreport Chassis Temps Or Omreport Mainsystem Temps

Use the omreport chassis temps or omreport mainsystem temps command to view properties of the system’s temperature probes. Type: omreport chassis temps index=n

44

or omreport mainsystem temps index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any temperature probes that are present on the system. If you specify the index, Server Administrator displays the summary for a specific temperature probe.

Omreport Chassis Volts Or Omreport Mainsystem Volts

Use the omreport chassis volts or omreport mainsystem volts command to view properties of the system’s voltage probes. Type: omreport chassis volts index=n or omreport mainsystem volts index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any voltage probes that are present on the system. If you specify the index, Server Administrator displays a summary for a specific voltage probe.

Omreport Licenses

Use the omreport licenses command to view the digital licenses of the hardware devices installed on the system. Type: omreport licenses

The following is an example output from the omreport licenses command:

Device Index

Device Status

Device

Device Description

Device ID

License Index

Description

Status

Recommended Action

License Type

EntitlementID

Expiry Date

: 0

: Ok

: iDRAC7

: iDRAC

: xxxx

: 0

: iDRAC7 Enterprise Evaluation License

: OK

: N/A

: Evaluation

: xxxx

: yyyy-mm-dd hh:mm:ss

45

Omreport System Commands Or Omreport

Servermodule Commands

Use the omreport system or omreport servermodule commands to view logs, threshold values, cost of ownership information, and information about how shutdown actions and recovery actions are configured.

Omreport System Or Omreport Servermodule

Use the omreport system or omreport servermodule command to see a general status of the components of the system. When you specify a level 3 command, such as omreport system shutdown or omreport servermodule shutdown, you get detailed information for one system component rather than the high-level status obtained with omreport system or omreport servermodule. Type: omreport system or omreport servermodule

If the system has both a main system chassis or main system and at least one direct attached storage device, Server Administrator may display a summary that resembles the following example:

SEVERITY : COMPONENT

Ok : Main System Chassis

Critical : Storage

Commands For Viewing Logs

Use the omreport system or omreport servermodule command to view the following logs: the alert log, the command log, and the hardware or ESM log.

NOTE: If the Alert log or Command log displays invalid XML data (such as when XML data generated for the selection is not well-formed), you must clear the log and resolve the issue. To clear the log, type: omconfig system alertlog action=clear or omconfig system cmdlog action=clear. If you need to retain the log information for future reference, save a copy of the

log before clearing. For more information about clearing logs, see Commands For Clearing Logs .

To view the contents of the alert log, type: omreport system alertlog or omreport servermodule alertlog

To view the contents of the command log, type: omreport system cmdlog or omreport servermodule cmdlog

46

To view the contents of the ESM log, type: omreport system esmlog or omreport servermodule esmlog

Overall Health Status Of The ESM Log

When you run the omreport system esmlog or omreport servermodule esmlog command, the ESM log is displayed. The first line of the report reflects the overall health of the system hardware. For example,

Health: OK means that less than 80 percent of the space allotted for the ESM log is occupied by messages. If 80 percent or more of the allotted space for the ESM log is occupied, the following caution is displayed:

Health: Non-Critical

If a caution is displayed, resolve all warning and critical severity conditions, and then clear the log.

Omreport System Alertaction Or Omreport Servermodule Alertaction

Use the omreport system alertaction or omreport servermodule alertaction command to view a summary of alert actions that have been configured for warning and failure events on the system components.

Alert actions determine how Server Administrator responds when a component has a warning or failure event.

The omreport system alertaction or omreport servermodule alertaction command is useful for viewing which alert actions have been specified for components. To set an alert action for a component, use the omconfig system alertaction or omconfig servermodule alertaction command. For more information, see

omconfig: Managing Components Using The Instrumentation Service .

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

Components And Events Having View Alert Actions

View alert action properties for the following components and events, if the components or events are present on the system:

• Battery Warning

• Battery Failure

• Chassis Intrusion

• Current Probe Warning

• Current Probe Failure

• Fan Warning

• Fan Failure

• Memory Pre-failure

• Memory Failure

• System Power Probe Warning

• System Power Probe Detects a Failure

47

• System Peak Power

• Power Supply Warning

• Power Supply Failure

• Degraded Redundancy

• Lost Redundancy

• Temperature Warning

• Temperature Failure

• Voltage Warning

• Voltage Failure

• Processor Warning

• Processor Failure

• Hardware Log Warning

• Hardware Log Full

• Watchdog Asr

• Storage System Warning

• Storage System Failure

• Storage Controller Warning

• Storage Controller Failure

• Physical Disk Warning

• Physical Disk Failure

• Virtual Disk Warning

• Virtual Disk Failure

• Enclosure Warning

• Enclosure Failure

• Storage Controller Battery Warning

• Storage Controller Battery Failure

• Removable Flash Media Present

• Removable Flash Media Removed

• Removable Flash Media Failure

NOTE: Storage Controller Battery Warning and Storage Controller Battery Failure events are not available on blade systems.

NOTE: System Power Probe Warning is not applicable to blade systems.

Omreport System Assetinfo Or Omreport Servermodule Assetinfo

Use the omreport system assetinfo or omreport servermodule assetinfo command to see cost of ownership data for the system, such as acquisition, depreciation, and warranty information. To set any of these fields, use the omconfig system assetinfo or omconfig servermodule assetinfo command. For more information, see

Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership Values .

48

Omreport System Events Or Omreport Servermodule Events

Use the omreport system events or omreport servermodule events command to view the currently enabled or disabled SNMP traps. Type: omreport system events or omreport servermodule events

This command displays a summary of each component in the system for which events are generated. For each component, the report shows which severities are set to report and which severities are set not to report. The following is an example output for a few components:

Current SNMP Trap Configuration

-----------

System

-----------

Settings

Enable: Informational, Warning and Critical

Disable: None

---------------

Power Supplies

----------------

Settings

Enable: Informational, Warning and Critical

Disable: None

-----------

Fans

-----------

Settings

Enable: Critical

Disable: Informational, Warning, and Critical

---------------------

Removable Flash Media

---------------------

Settings

Enable: Informational, Warning and Critical

Disable: None

The full report lists the settings for all components in the system for which events are generated.

Omreport System Events Type Or Omreport Servermodule Events Type

To view the status for components of a specific type, use the omreport system events type=<component name> or omreport servermodule event type=<component name> command. Type: omreport system events type=fans or omreport servermodule events type=fans

This command displays a summary of each component in the system for which events are generated.

The following table displays the events displayed for various component types.

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

49

Table 14. Valid Parameters Of Omreport System Events Type Or Omreport Servermodule Events Type name=value pair type=accords type=battery type=fanenclosures type=fans type=intrusion type=log type=memory type=powersupplies type=redundancy type=systempower type=temps type=removableflashmedia type=volts

Description

Reports events for AC power cords

Reports events for batteries

Reports events for fan enclosures

Reports events for fans

Reports events for chassis intrusion

Reports events for logs

Reports events for memory

Reports events for power supplies

Reports events for redundancy

Reports events for system power

Reports events for temperatures

Reports events for removable flash media

Reports events for voltages

The following is an example output:

Current SNMP Trap Configuration

-------

System

-------

Settings

Enable: Informational, Warning, and Critical

Disable: None

-----------

Fans Group

----------

Settings

Enable: Informational, Warning, and Critical

Disable: None

-----------

Individual Objects

-----------

System Board Fan1 RPM Settings

Index:0

Enable: Informational, Warning, and Critical

Disable: None

System Board Fan2 RPM Settings

Index:1

Enable: Informational, Warning, and Critical

Disable: None

Omreport System Operatingsystem Or Omreport Servermodule

Operatingsystem

Use the omreport system operatingsystem or omreport servermodule operatingsystem command to display information about the operating system.

50

Omreport System Pedestinations Or Omreport Servermodule Pedestinations

Use the omreport system pedestinations or omreport servermodule pedestinations command to view destinations where alerts are sent for platform events. Depending on the number of destinations displayed, configure a separate IP address for each destination address. Type: omreport system pedestinations or omreport servermodule pedestinations

The output of the omreport system pedestinations or omreport servermodule pedestinations command lists each of the valid parameters.

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

Destination Configuration Settings For The Omreport System Pedestinations Or Omreport

Servermodule Pedestinations

The actual number of destinations that you can configure on a system using omreport system pedestinations or omreport servermodule pedestinations may differ.

The following table displays the available settings.

Table 15. Settings For The Omreport System Pedestinations Or Omreport Servermodule Pedestinations

Output

Destination List

Attributes Description

Destination Number:

Destination1 destination 1: Displays the first destination.

Example:

101.102.103.104: IPv4 address of the first destination.

Destination Number:

Destination 2

Destination Number:

Destination 3

Destination Number:

Destination 4 destination 2: Displays the second destination.

Example:

110.120.130.140: IPv4 address of the second destination.

destination 3: Displays the third destination.

Example:

201:202:203:204: IPv4 address of the third destination.

destination 4: Displays the fourth destination.

Example:

210.211.212.213: IPv4 address of the fourth destination.

51

Output Attributes

Destination Number:

Destination 5

Destination Number:

Destination 6

Destination Number:

Destination 7

Destination Number:

Destination 8

Description destination 5: Displays the fifth destination.

Example:

2001:0db8:85a3:0000:0000:8a2e:0370:7334: IPv6 address of the fifth destination.

destination 6: Displays the sixth destination.

Example:

2001:0db8:85a3:0000:0000:8a2e:0370:7334: IPv6 address of the sixth destination.

destination 7: Displays the seventh destination.

Example:

210.211.212.213: IP address of the seventh destination.

destination 8: Displays the eighth destination.

Example:

210.211.212.213: IP address of the eighth destination.

Destination

Configuration Settings attribute=communityst ring communitystring: Displays the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station

.

NOTE: On 12G systems with iDRAC7 specific versions, ipaddress can also be a Fully Qualified

Domain Name (FQDN).

Omreport System Platformevents Or Omreport Servermodule

Platformevents

Use the omreport system platformevents or omreport servermodule platformevents command to view how the system responds for each listed platform event.

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.

Omreport System Recovery Or Omreport Servermodule Recovery

Use the omreport system recovery or omreport servermodule recovery command to see whether there is an action configured for a hung operating system. You can also view the number of seconds that must elapse before an operating system is considered hung.

52

Omreport System Shutdown Or Omreport Servermodule Shutdown

Use the omreport system shutdown or omreport servermodule shutdown command to view any pending shutdown actions for the system. If properties for shutdown are configured, executing this command displays these properties.

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

Omreport System Summary Or Omreport Servermodule Summary

Use the omreport system summary or omreport servermodule summarycommand to view a comprehensive summary of software and hardware components currently installed on the system. Type: omreport system summary or omreport servermodule summary

NOTE: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.

NOTE: If iDRAC is installed, Server Administrator displays the LCC version. If BMC is installed, Server

Administrator displays the USC version.

The output that is displayed in the CLI window depends on the systems management software, operating system, and hardware components and options installed on the system. The following partial command results are unique and may not resemble the hardware and software configuration of the system:

System Summary

-----------------

Software Profile

-----------------

Systems Management

Name

Version

Description

Contains

: Dell OpenManage Systems Management Software (64–

Bit)

: x.x.x

: Systems Management Software

Apache Tomcat Webserver x.x.x

: Common Storage Module x.x.x

: Data Engine x.x.x

: Hardware Application Programming Interface x.x.x

: Instrumentation Servicex.x.x

: Instrumentation Service Integration Layer x.x.x

Intel SNMP Agent x.x.x

53

Operating System

Name

Version

System Time

System Bootup Time

-------

Server Module

-------

Information

Host Name

System Location

Model

Asset Tag

Service Tag

Express Service Code

Slot Number

Slot Name

Form Factor

Node Id

: Inventory Collector x.x.x

: OMACS x.x.x

: Operating System Loggingx.x.x

: Oracle Java Runtime Environment x.x.x

: Remote Access Controller Managed Node x.x.x

: Server Administrator Common Framework x.x.x

: Server Administrator Core files x.x.x

: Server Administrator Instrumentation files x.x.x

: Server Administrator Core files x.x.x

: Server Instrumentation SNMP Module x.x.x

: Server Instrumentation WMI Module x.x.x

: Storage Management x.x.x

: Microsoft Windows Server 2008 R2, Enterprise x64

Edition

: Version 6.1 (Build 7601 : Service Pack 1) (x64)

Server Full Installation

: Fri May 20 18:02:52 2XXX

: Wed May 18 18:37:58 2XXX

: WIN-GSFCCED6N2D

: Please set the value

: PowerEdge FM120

SST,3,4,S

CB2DX1S

26790524560

Slot =8

SLOT-02

1U Half Width

CB2DX1Sc

54

Remote Access Information

Remote Access Device vFlash Media

: iDRAC7 Express

: Absent

Processor 1

Processor Brand

Processor Version

Voltage

: Genuine Intel (R) CPU 4000 @ 2.41GHz

: Model 77

: 1000 mV

Memory

Total Installed Capacity :4096 MB

Memory Available to the OS :4096 MB

Total Maximum Capacity

Memory Array Count

:32768 MB

: 1

Memory Array 1

Location

Use

Installed Capacity

Maximum Capacity

Slots Available

Slots Used

ECC Type

: System Board or Motherboard

: System Memory

: 4096 MB

: 32768 MB

: 24

: 1

: Multibit ECC

BIOS Information

Manufacturer

Version

Release Date

Firmware Information

Name

Version

Firmware Information

Name

Version

---------------

: Dell Inc.

: 0.1.10

: 07/31/2013

: iDRAC7

: 1.50.50 (Build 3)

: Lifecycle Controller 2

: 1.3.0.518

55

Remote Access Controller

---------------

Remote Access Controller

Information

Product

IP Address

IP Subnet

IP Gateway

IPv6 Address 1

IPv6 Address 2

IPv6 Gateway

---------------

Network Data

---------------

Network Interface 0

IP Address

Subnet Mask

Default Gateway

MAC Address

Network Interface 1

IP Address

Subnet Mask

Default Gateway

MAC Address

: iDRAC7 Express

: 10.94.146.217

: 255.255.255.0

: 10.94.146.1

: ::

: ::

: ::

: xx.xx.xx.xx

: xx.xx.xx.xx

: xx.xx.xx.xx

: : xx-xx-xx-xx-xx-xx

: xx.xx.xx.xx

: xx.xx.xx.xx

: xx.xx.xx.xx

: : xx-xx-xx-xx-xx-xx

Hardware Information Using Omreport System Summary Or Omreport Servermodule

Summary

The system summary hardware information includes data values for installed components of the following types present in the system:

System Attributes

• Host Name

• System Location

• Life Cycle Controller

Main System Chassis Or Main System

56

Chassis

Remote Access

Information

Processor

• Remote Access Device

• vFlash Media

• vFlash Media Size

The following are listed for each processor in the system:

• Processor Brand

• Processor Family

• Processor Version

• Current Speed

• Maximum Speed

• External Clock Speed

• Voltage

Memory

• Chassis Model

• Chassis Service Tag

• Express Service Code

• Chassis Lock

• Chassis Asset Tag

Memory Array

• Total Installed Capacity

• Memory Available to the Operating System

• Total Maximum Capacity

• Memory Array Count

The following details are listed for each memory board or module in the system

(for example, the system board or the memory module in a given slot number):

• Location

• Use

• Installed Capacity

• Maximum Capacity

• Slots Available

• Slots Used

• ECC Type

BIOS

• Manufacturer

• BIOS Version

• Release Date

Firmware

• Name

57

• Version

Network Data

The following details are listed for each NIC and Team interface, if Team interface is configured in the system:

• IP Address

• Subnet Mask

• Default Gateway

• MAC Address

Storage Enclosures

The following details are listed for each storage enclosure attached to the system:

• Name

• Service Tag

Omreport System Thrmshutdown Or Omreport Servermodule

Thrmshutdown

Use the omreport system thrmshutdown or omreport servermodule thrmshutdown command to view the properties configured for a thermal shutdown action.

The three properties that display for thermal shutdown are disabled, warning, or failure. If the CLI displays the following message, the thermal shutdown feature has been disabled:

Thermal protect shutdown severity: disabled

If the system is configured to shutdown when a temperature probe detects a warning or failure event, one of the following messages is displayed:

Thermal protect shutdown severity: warning

Thermal protect shutdown severity: failure

Omreport System Version Or Omreport Servermodule Version

Use the omreport system version or omreport servermodule version command to list the version numbers of the BIOS, firmware, systems management software, and operating system installed on the system. Type: omreport system version or omreport servermodule version

NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server Administrator displays the USC version.

The output that is displayed in the CLI window depends on the version of the BIOS, RAID controllers, and firmware installed on the system. The following partial command results are unique and may not resemble the results for the configuration of the system:

Version Report

---------------------

58

Main System Chassis

---------------------

Name : BIOS

Version : 0.3.5

Name : iDRAC7

Version : 1.00

---------------------

Software

---------------------

Name : Microsoft Windows Server 2008 R2, Enterprise x64 edition

Version : Version 6.1 (Build 7600) (x64) Server Full Installation

Name : Dell Server Administrator

Version : 7.x.x

------------------------------------

Storage Controller Firmware

------------------------------------

Name : PERC H310 Mini

Version : 20.10.1-0025

Omreport Preferences Commands

Use the omreport preferences command to view the URL details of the Server Administrator Web server, key sign algorithm, JRE, and message format.

Omreport Preferences Messages

Use the omreport preferences messages to view the configured alert message format.

The following table lists the available attributes of omreport preferences messages.

Table 16. Valid Parameters Of Omreport Preferences Messages name=value pair attribute=format

Description

Reports the currently configured alert message format.

Type: omreport preferences messages attribute=format

The output that is displayed is as follows:

Event Message Format : enhanced

Omreport Preferences Webserver

Use the omreport preferences webserver command to view the URL details, current key sign algorithm, and the JRE details.

The following table lists the available attributes of omreport preferences webserver.

59

Table 17. Valid Parameters Of Omreport Preferences Webserver name=value pair attribute=geturl attribute=getsignalgorithm attribute=getjre attribute=getjrelist

Description

Reports the URL information of the Web server.

Reports the current key sign algorithm.

Displays JRE currently being used.

Displays the Server Administrator supported JRE versions installed in the system.

Type: omreport preferences webserver attribute=getjrelist

The output that is displayed is as follows:

Version: 1.7.0_05 (Bundled)

Path : C:\Program Files <x86>\Dell|SysMgt\jre

Version:1.7.0_03

Path:C:\Program Files <x86>\Java\jre7

60

4

Omconfig: Managing Components Using

The Instrumentation Service

The omconfig command allows you to provide values that define warning events, configure alert actions, clear logs, and configure system shutdown, as well as perform other systems management tasks.

Examples of omconfig capabilities include:

• Administrator privilege to clear command, alert, and hardware logs

• Administrator privilege to configure and execute system shutdown

• Power user and administrator privilege to specify values for warning events on fans, voltage probes, and temperature probes

• Power user and administrator privilege to set alert actions in case of a warning or failure event from intrusion, fans, voltage probes, and temperature probes

For more information on using the omconfig command to view and manage cost of ownership information (assetinfo), see

Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership

Values

.

Often, you must use the omreport commands to get the information required to execute an omconfig command. For example, to edit the minimum temperature for a warning event on a temperature probe, you must know the index of the probe. Use the omreport chassis temps or omreport mainsystem temp command to display a list of probes and their indexes. For more information on using the omreport command, see

Omreport: Viewing System Status Using The Instrumentation Service .

The following table displays the system availability for the omconfig command:

Table 18. System Availability For The Omconfig Command

Command Level 1 omconfig

Command Level 2 servermodule mainsystem system chassis

Applicable to

Blade systems

Blade systems

Rack and Tower systems

Rack and Tower systems

Conventions For Parameter Tables

When listing the parameters that a command can take, the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface.

61

The symbol |, often called pipe, is the logical exclusive or operator. For example, enable | disable means you can enable or disable the component or feature, but you cannot simultaneously enable and disable the component or feature.

omconfig Command Summary

The following table provides a high-level summary of the omconfig command. The columns titled

Command level 2 and Command level 3 list the major arguments that are used with omconfig. User

privilege required refers to the type of privilege you need to run the command, where U = User, P =

Power User, and A = Administrator. Use is a very general statement about the actions that are performed using omconfig.

NOTE: Although the following table lists all possible omconfig commands, the commands available on the system depend on the system configuration. If you try to get help or run a command for a component not installed on the system, Server Administrator displays a message that the component or feature is not found on the system.

NOTE: When CSIOR (Collect System Inventory on Restart) is disabled, omconfig does not allow to configure the BIOS settings.

Table 19. omconfig Command Level 1, Level 2, and Level 3

Comman d Level 1

Command

Level 2

Command

Level 3

User

Privilege

Required

Use omconfig about details=true

U, P, A

U, P, A

Shows the version number and properties for the Server Administrator program.

Displays information for all Server Administrator programs that are installed.

preferences cdvformat dirservice messages useraccess webserver

A

A

A

A

A

Specifies the delimiter for separating data fields reported in custom delimited format (cdv).

Configures the Microsoft Active Directory service.

Displays the configured alert message format.

Determines whether users below the administrator level are allowed to use Server

Administrator or not.

Allows the administrator to set the encryption levels of the Web server and configure the URL launch point in the Server Administrator Web server environment.

system or servermodule

62

Comman d Level 1

Command

Level 2

Command

Level 3 alertaction alertlog assetinfo cmdlog esmlog events

P, A

P, A pedestinations P, A platformevent s

A recovery shutdown thrmshutdow n webserver

User

Privilege

Required

P, A

Use

P, A

P, A

P, A

P, A

A

A

A

Determines in advance the actions taken for warning or failure events on intrusion, fans, temperatures, voltages, power supplies, memory, and redundancy.

Allows the administrator to clear the alert log.

Enters and edits cost of ownership information for the system, including values for depreciation, lease, maintenance, service, and support.

Allows the administrator to clear the command log.

Allows the administrator to clear the ESM log.

Enables or disables SNMP traps.

Sets IP addresses for alert destinations.

Determines the shutdown action, if any, taken for a specific platform event. Also, enables or disables platform events filter alert generation.

Determines in advance how the system responds to a hung operating system.

Allows the administrator to select from several options when shutting down the system.

Sets the severity level at which a thermal event triggers a system shutdown.

Starts or stops the Web server.

chassis or mainsystem biossetup fans frontpanel info

A

P, A

A

P, A

Configures the behavior of specific system components controlled by the BIOS.

Configures fan probe warning thresholds to the default or a specific value.

NOTE: You cannot change threshold values on embedded server management (ESM3) and Dell PowerEdge x8xx systems.

Configures the Power button, Non-Masking

Interrupt (NMI) button, encryption access, and

LCD display of the system.

Allows you to set an initial value, or to edit the value of the asset tag or chassis name.

63

Comman d Level 1

Command

Level 2 storage

Command

Level 3 leds memorymode A pwrmanagem ent pwrmonitorin g

User

Privilege

Required

P, A

Use

P, A

P, A remoteaccess A temps P, A

Specifies when to flash a chassis fault LED or chassis identification LED, and allows you to clear the LED for the system's hard drive.

Enables or disables the spare bank, mirroring, raid, and Double Device Data Correction

(DDDC) memory modes, and also specify which mode to use.

Allows you to choose between maximum power, economy, and optimized performance of the system.

Configures power consumption information and thresholds.

Configures remote access information.

Sets warning threshold values to the default or a specific value.

NOTE: You cannot change threshold values on ESM3 and PowerEdge x8xx systems.

volts P, A

Sets warning threshold values to the default or a specific value.

NOTE: You cannot change threshold values on ESM3 and PowerEdge x8xx systems.

For more information, see

Using The Storage

Management Service .

Help With The Omconfig Command

The following table lists the usage of omconfig commands.

Table 20. Usage Of Omconfig Commands

Command Usage omconfig -?

omconfig <command level 2> -?

omconfig chassis -?

omconfig system -?

Description

To display the list of the available commands for omconfig.

To display the help for about, chassis, preferences, and system’s level 2 commands.

To display the help for omconfig chassis command.

To display the help for omconfig system command.

omconfig preferences

-?

To display the available commands for omconfig preferences, such as cdvformat, which is the custom delimiter format (cdv).

omconfig preferences cdvformat -?

To display the list of delimiter values for the cdv.

64

Command Usage omconfig system

<command level 3> -?

Description

To display the list of the parameters you must use to execute a particular omconfig system command.

To display the list of valid parameters for omconfig system alertaction.

omconfig system alertaction -?

omconfig system shutdown -?

To display the list of valid parameters for omconfig system shutdown.

omconfig system alertaction -? | more omconfig system alertaction -? -outa alert.txt

more alert.txt

To display the list of valid parameters for omconfig system alertaction and to scroll the command output one screen at a time. Here, | more allows you to press the spacebar to see the next screen of the CLI help output.

To create a file that contains all the help for the omconfig system alertaction -? command. Here, -outa directs the output of the command to a file called alert.txt .

To read the help for the alertaction command on Microsoft Windows, Red Hat

Enterprise Linux, or SUSE Linux Enterprise Server operating systems.

Omconfig About

Use the omconfig about command to learn the product name and version number of the systems management application installed on the system. The following is an example output of the omconfig about command:

Product name

: Dell OpenManage Server Administrator

Version : 7.x.x

Copyright : Copyright (C) Dell Inc. xxxx-xxxx. All rights reserved.

Company : Dell Inc.

For more details about the environment for Server Administrator, type: omconfig about details=true

Server Administrator includes a number of services, each having a version number of its own. The

Contains field reports version numbers for the services and provides other useful details. The output may change depending on the configuration of the system and the version of Server Administrator.

Contains: Broadcom SNMP Agent 10.xx.xx

Common Storage Module 3.x.x

Data Engine 5.x.x

Hardware Application Programming Interface 5.x.x

Instrumentation Service 6.x.x

Instrumentation Service Integration Layer 1.x.x

Intel SNMP Agent 1.xx.x

65

OpenManage Inventory Collector 6.x.x

OpenManage Tools 6.x.x

Remote Access Controller 4 Data Populator 4.x.x

Remote Access Controller 4 Managed Node 4.6.3

Secure Port Server 1.x.x

Server Administrator Framework 6.x.x

Agent for Remote Access 1.x.x

Storage Management 3.x.x

Sun Java Runtime Environment 1.x.xx

Omconfig Chassis Or Omconfig Mainsystem

Use the omconfig chassis or omconfig mainsystem commands to:

• Set to default or assign specific values for fan, voltage, and temperature probes

• Configure BIOS behavior during system start up

• Clear memory error counts

• Enable or disable power button control features if the system configuration permits

Use the omconfig chassis -? or omconfig mainsystem -? command to view a list of all omconfig chassis or omconfig mainsystem commands.

Omconfig Chassis Biossetup Or Omconfig Mainsystem Biossetup

Use the omconfig chassis biossetup or omconfig mainsystem biossetup command to configure system

BIOS settings that are normally available only in the BIOS setup boot time settings of the system.

CAUTION: Changing certain BIOS setup options may disable the system or require you to reinstall the operating system.

NOTE: Reboot the system for the BIOS setup options to take effect.

NOTE: Not all BIOS setup options are available on every system.

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

NOTE: When CSIOR (Collect System Inventory on Restart) is disabled, you cannot configure the

BIOS settings using omconfig command.

BIOS Setup Settings On Systems Prior To PowerEdge 12G Systems

The following table displays the name=value pairs that you can use with omconfig chassis biossetup or omconfig mainsystem biossetup command on systems prior to PowerEdge12G systems.

66

Table 21. BIOS Setup Settings on systems prior to PowerEdge 12G systems name=value pair 1 attribute= attribute=acpwrrecovery name=value pair 2 setting= setting=off | last| on

Description

• off: System is turned off.

• last: System returns to the previous state.

• on: System is turned on.

delay=random | immediate | timedelay <value> attribute=bezel attribute=bootsequence setting=enabled | disabled setting=diskettefirst | hdonly | devicelist | cdromfirst | opticaldrive

• random: System is turned on with random delay.

• immediate: System returns to previous state immediately.

• timedelay <value>: System is turned on based on the user specified time delay.

• enabled: Enables the bezel removal intrusion check during system boot.

• disabled: Disables the bezel removal intrusion check during system boot.

Instructs the BIOS which device is used to boot the system, and the order in which the boot routine checks each device.

NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting.

attribute=bootmode attribute=bootorder setting=uefi | bios sequence=aliasname1, aliasname2,..... aliasnameN

• uefi: Enables the system to boot to operating systems that support Unified

Extensible Firmware Interface

(UEFI).

• bios: Enables the system to boot to operating systems that do not support UEFI.

Configures the boot sequence according to the set aliasnames.

To view the set alias names, run the command omreport chassis biossetup attribute=bootorder

NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting.

67

name=value pair 1 attribute= attribute=hddorder name=value pair 2 setting= sequence=aliasname1, aliasname2,..... aliasnameN attribute=cstates attribute=conredirect attribute=crab attribute=cpucle attribute=cpuht attribute=cpuvt setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled setting=enabled | disabled

Description

Configures the BIOS setup hard disk sequence according to the set aliasnames. Changes takes effect after rebooting the system.

To view the set alias names, run the command omreport chassis biossetup attribute=bootorder

NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting.

• enabled: Enables the processor to go into a deep sleep state when the system is not utilized.

• disabled: Disables the processor to go into a deep sleep state when the system is not utilized.

• enabled: Redirects the BIOS screen output over serial port

1. Keyboard and text output are redirected over serial port

2.

• disabled: Turns off the BIOS console redirection.

• enabled: Enables BIOS console redirection after system reboot.

• disabled: Disables BIOS console redirection.

NOTE: The attribute crab is valid for Dell PowerEdge 9G systems only.

• enabled: Enables processor

C1-E after system reboot.

• disabled: Disables processor

C1-E after system reboot.

• enabled: Enables logical processor hyperthreading.

• disabled: Disables logical processor hyperthreading.

• enabled: Enables virtualization.

68

name=value pair 1 attribute= attribute=cpuxdsupport attribute=cpucore attribute=dbs attribute=diskette attribute=dualnic name=value pair 2 setting= setting=enabled | disabled

Description

• disabled: Disables virtualization.

• enabled: Enables Execute

Disable (XD) support on the system.

• disabled: Disables XD support on system.

setting=1 | 2 | 4 | 6 | 8 | 10 | 12 |all • 1: Enables one core per processor.

• 2: Enables two cores per processor.

• 4: Enables four cores per processor.

• 6: Enables six cores per processor.

• 8: Enables eight cores per processor.

• 10: Enables ten cores per processor.

• 12: Enables twelve cores per processor.

• all: Enables the maximum cores per processor.

setting=enable | disable • enable: Enables Demand

Based Switching (DBS) on the system.

• disable: Disables DBS on the system.

setting=off | auto | writeprotect

• off: Disables the diskette drive.

• auto: Auto-enables the diskette drive.

• writeprotect: The diskette drive is available in read-only format only. Makes the diskette drive read-only.

setting=off | on | pxeboth | nic1pxe |nic2pxe | isciboth | nic1isci | nic2isci | nic1pxenic2isci

| nic1iscinic2pxe | onpxeboth | onpxenone | onpxenic1 | onpxenic2

• off: Disables the Network

Interface Controllers (NICs).

• on: Enables the network interface (PXE or iSCSI is not enabled on either of the

NICs).

• pxeboth: Enables PXE on both NICs.

• nic1pxe: Enables PXE on the first NIC and none (no PXE or iSCSI) on the second NIC.

• nic2pxe: Enables none (no

PXE or iSCSI) on first NIC and

PXE on the second NIC.

69

name=value pair 1 attribute= attribute=embhypvisor attribute=embvideoctrl attribute=esataport attribute=extserial attribute=fbr name=value pair 2 setting= setting=enabled | disabled setting=enabled | disabled setting=off | auto setting=com1 | com2 | rad setting=9600 | 19200 | 57600 |

115200

Description

• isciboth: Enables iSCSI on both the NICs.

• nic1isci: Enables iSCSI on the first NIC and none (no PXE or iSCSI) on the second NIC.

• nic2isci: Enables none (no

PXE or iSCSI) on the first NIC and iSCSI on the second NIC.

• nic1pxenic2isci: Enables PXE on the first NIC and iSCSI on second NIC.

• nic1iscinic2pxe: Enables iSCSI on the first NIC and PXE on second NIC.

The following options are deprecated:

• onpxeboth: Enables PXE on both the NICs.

• onpxenone: PXE is not enabled on either of the NICs.

• onpxenic1: Enables PXE on

NIC 1.

• onpxenic2: Enables PXE on

NIC 2.

• enabled: Enables the embedded hypervisor.

• disabled: Disables the embedded hypervisor.

• enabled: Enables the embedded video controller as the primary video device.

• disabled: Disables the embedded video controller as the primary video device.

• off: Sets the embedded SATA port value to off.

• auto: Sets the embedded

SATA port value to auto.

• com1: Maps the external serial connector to COM 1.

• com2: Maps the external serial connector to COM 2.

• rad: Maps the external serial connector to the remote access device.

• 9600: Sets the console redirection failsafe baud rate to 9600 bits per second.

70

name=value pair 1 attribute= attribute=htassist attribute=ide attribute=idepridrv name=value pair 2 setting= setting=enabled | disabled setting=on | off force=true setting=off | auto

Description

• 19200: Sets the console redirection failsafe baud rate to 19200 bits per second.

• 57600: Sets the console redirection failsafe baud rate to 57600 bits per second.

• 115200: Sets the console redirection failsafe baud rate to 115200 bits per second.

• enabled: Enables the probe filter chipset option.

• disabled: Disables the probe filter chipset option.

NOTE: Certain applications do not function fully if you enable or disable this option.

• on: Enables IDE.

• off: Disables IDE.

• force=true: Verification of setting change.

• off: Disables the device.

• auto: Detects and enables the device automatically.

attribute=intrusion setting=enabled | disabled • enabled: Enables the intrusion check during system boot. If the system also has bezel intrusion checking, then the intrusion option checks for removal of the bezel of the system.

• disabled: Disables the intrusion check during system boot.

• enabled: Enables the internal

USB port.

• disabled: Disables the internal

USB port.

attribute=intusb[1..2]

NOTE: The following option is deprecated: attribute=intusb setting=enabled | disabled attribute=mouse attribute=nic1 setting=on | off

• on: Enables the mouse.

• off: Disables the mouse.

setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi

• enabled: Enables the first NIC during system boot.

• enabledwithpxe: Enables the first NIC during system boot

(with PXE on if the system has

PXE).

71

name=value pair 1 attribute= attribute=nic2 attribute=nic3 name=value pair 2 setting= Description

• disabled: Disables the first

NIC during system boot.

• enabledonly: Enables the first

NIC during system boot (with

PXE off if the system has PXE).

• enablednonepxe: Enables the first NIC during system boot

(with PXE off if the system has

PXE).

• enabledwithiscsi: Enables the first NIC during system boot

(with iSCSI on if the system has iSCSI).

setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi

• enabled: Enables the second

NIC during system boot.

• enabledwithpxe: Enables the second NIC during system boot (with PXE on if the system has PXE).

• disabled: Disables the second

NIC during system boot.

• enabledonly: Enables the second NIC during system boot (with PXE off if the system has PXE).

• enablednonepxe: Enables the second NIC during system boot (with PXE off if the system has PXE).

• enabledwithiscsi: Enables the second NIC during system boot (with iSCSI on if the system has iSCSI).

setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi

• enabled: Enables the third

NIC during system boot.

• enabledwithpxe: Enables the third NIC during system boot

(with PXE on if the system has

PXE).

• disabled: Disables the third

NIC during system boot.

• enabledonly: Enables the third NIC during system boot

(with PXE off if the system has

PXE).

• enablednonepxe: Enables the third NIC during system boot

(with PXE off if the system has

PXE).

• enabledwithiscsi: Enables the third NIC during system boot

(with iSCSI on if the system has iSCSI).

72

name=value pair 1 attribute= attribute=nic4 attribute=numlock attribute=NodeInterleave

NOTE: Use

NodeInterleave instead of numa as numa will be deprecated in future releases.

name=value pair 2 setting= setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi

Description

• enabled: Enables the fourth

NIC during system boot.

• enabledwithpxe: Enables the fourth NIC during system boot (with PXE on if the system has PXE).

• disabled: Disables the fourth

NIC during system boot.

• enabledonly: Enables the fourth NIC during system boot (with PXE off if the system has PXE).

• enablednonepxe: Enables the fourth NIC during system boot (with PXE off if the system has PXE).

• enabledwithiscsi: Enables the fourth NIC during system boot (with iSCSI on if the system has iSCSI).

setting=on | off setting=enabled | disabled

• on: Uses the keypad as number keys.

• off: Uses the keypad as arrow keys.

• enabled: Enables Node

Interleaving and disables Non-

Uniform Memory Access.

• disabled: Disables Node

Interleaving and enables Non-

Uniform Memory Access.

attribute=ppaddress setting=off | lpt1 | lpt2 | lpt3 attribute=ppmode setting=at | ps2 | ecp | epp

• off: Disables the parallel port address.

• lpt1: Locates the device on

LPT1.

• lpt2: Locates the device on

LPT2.

• lpt3: Locates the device on

LPT3.

• at: Sets the parallel port mode to AT.

• ps2: Sets the parallel port mode to PS/2.

• ecp: Sets the parallel port mode to ECP (extended capabilities port).

• epp: Sets the parallel port mode to EPP (enhanced parallel port).

73

name=value pair 1 attribute= attribute=primaryscsi attribute=romb attribute=romba attribute=rombb attribute=sata name=value pair 2 setting= setting=on | off force=true setting=raid | off | scsi force=true • raid: Instructs the BIOS to detect RAID-on-motherboard as a RAID device.

• off: Disables RAID-onmotherboard during system boot.

• scsi:Instructs the BIOS to detect the RAID-onmotherboard device as a SCSI device.

• force=true: Verification of setting change.

setting=raid | scsi force=true

• raid: Instructs the BIOS to detect RAID-on-motherboard channel A as a RAID device.

• scsi: Instructs the BIOS to detect the RAID-onmotherboard device as a SCSI device.

• force=true: Verification of setting change.

setting=raid | scsi force=true setting=off | ata | raid attribute=sataport (0...7) or (a...h) setting=off | auto

Description

CAUTION: If you modify the setting for primary scsi, romb, romba, or rombb, the system becomes inoperable until you reinstall the operating system.

• on: Enables this device.

• off: Disables this device.

• force=true: Verification of setting change.

• raid: Instructs the BIOS to detect RAID-on-motherboard channel B as a RAID device.

• scsi: Instructs the BIOS to detect the RAID-onmotherboard device as a SCSI device.

• force=true: Verification of setting change.

• off: Disables the SATA controller.

• ata: Sets the onboard SATA controller to ATA mode.

• raid: Sets the onboard SATA controller to RAID mode.

• off: Disables the SATA port.

74

name=value pair 1 attribute= attribute=secondaryscsi attribute=serialportaddr attribute=serialcom attribute=serialport1 name=value pair 2 setting= setting=on | off

Description

• auto: Automatically enables the SATA port.

• on: Enables secondary SCSI.

• off: Disables this device.

setting=default | alternate | com1

| com2

• default: Maps to Serial device1=COM1, Serial device2=COM2.

• alternate: Maps to Serial device1=COM2, Serial device2=COM1

• com1: Sets serial port address to COM1.

• com2: Sets serial port address to COM2.

setting=off | on | com1 | com2 | onwithconsole

• off: Disables serial communication setting.

• on: Enables serial communication setting without console redirection.

• com1: Enables serial communication setting with console redirection through

COM1.

• com2: Enables serial communication setting with console redirection through

COM2.

• onwithconsole: Enables serial communication with console redirection through COM1 and COM2.

NOTE: The setting onwithconsole is supported only on Dell blade systems.

setting=off | auto | com1 | com3 | bmcserial | bmcnic | rac | com1bmc

• off: Disables serial port 1.

• auto: Maps serial port 1 to a

COM port.

• com1: Maps serial port 1 to

COM port 1.

• com3: Maps serial port 1 to

COM port 3.

• bmcserial: Maps serial port 1 to BMC Serial.

• bmcnic: Maps serial port 1 to the Baseboard Management

Controller (BMC) NIC.

• rac: Maps serial port 1 to the

Remote Access Controller

(RAC.)

75

name=value pair 1 attribute= attribute=serialport2 attribute=speaker attribute=cputurbomode attribute=uausb attribute=usb attribute=usbb name=value pair 2 setting= Description

• com1bmc: Maps serial port 1 to COM port 1 bmc.

NOTE: This command is applicable only on selected

x8xx systems.

setting=off | auto | com2 | com4 • off: Disables serial port 2.

• auto: Maps serial port 2 to a

COM port.

• com2: Maps serial port 2 to

COM port 2.

• com4: Maps serial port 2 to

COM port 4.

setting=on | off setting=enabled | disabled

• on: Enables the speaker.

• off: Disables the speaker.

CPU turbo mode can increase the CPU frequency when the system is operating below the thermal, power, or current limits.

• enabled: Enables CPU Turbo

Mode.

• disabled: Disables CPU Turbo

Mode.

setting=on | backonly | off setting=enabled | disabled setting=enabled | enabledwithbios | disabled

• on: Enables the useraccessible USB port(s).

• backonly: Enables only the user-accessible USB port(s) located at the back of the system.

• off: Disables the useraccessible USB port(s).

• enabled: Enables the USB port(s).

• disabled: Disables the USB port(s).

NOTE: Depending on the system's hardware you can configure either usb or usbb.

• enabled: Enables the USB port(s) during system boot, without BIOS support.

• enabledwithbios: Enables the

USB port(s) during system boot, with BIOS support.

• disabled: Disables the USB port(s) during system boot.

76

name=value pair 1 attribute= attribute=cstates name=value pair 2 setting= setting=enabled | disabled

Description

NOTE: Depending on the system's hardware you can configure either usb or usbb.

• enabled: Enables the processor to go into a deep sleep state when the system is not utilized.

• disabled: Disables the processor from going into a deep sleep state when the system is not utilized.

BIOS Setup Settings On PowerEdge 12G systems

The following table lists the BIOS setup attributes supported on PowerEdge 12G systems. On PowerEdge

12G systems, the attributes are grouped. Based on the hardware configuration, the possible attributes may vary in a specific group. The omconfig chassis biossetup command does not display the read-only attributes.

NOTE: If you have configured the setup password, then, always set the same when you configure any BIOS settings.

Table 22. BIOS Setup Settings On PowerEdge 12G Systems

Group

BIOS Boot

Settings name=value pair 1 attribute= attribute=BootSeq

Boot Settings

Integrated

Devices attribute=HddSeq attribute=BootMode attribute=BootSeqRetry

Embedded Server

Management attribute=FrontLcd attribute=UserLcdStr attribute=EmbVideo attribute=IntegratedNetwork1 attribute=IntegratedNetwork2 attribute=IntegratedRaid attribute=IntegratedSas attribute=InternalSdCard attribute=InternalSdCardRedun dancy attribute=InternalUsb name=value pair 2 setting= sequence=aliasname1, aliasname2,..... aliasnameN sequence=aliasname1, aliasname2,..... aliasnameN setting=Bios | Uefi setting=Enabled | Disabled setting=None | UserDefined | ModelNum |

Advanced setting=<string> setting=Enabled | Disabled setting=Enabled | DisabledOs setting=Enabled | DisabledOs setting=Enabled | Disabled setting=Enabled | Disabled setting=On | Off setting=Mirror | Disabled setting=On | Off

77

Group name=value pair 1 attribute= attribute=InternalUsb1 attribute=InternalUsb2 attribute=IoatEngine attribute=OsWatchdogTimer attribute=SriovGlobalEnable attribute=UsbPorts

Memory Settings attribute=MemOpMode attribute=MemOpVoltage name=value pair 2 setting= setting=On | Off setting=On | Off setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled setting=AllOn | OnlyBackPortsOn | AllOff setting=OptimizerMode | SpareMode | MirrorMode

|AdvEccMode | SpareWithAdvEccMode setting=AutoVolt | Volt15V

NOTE: Volt15V represents 1.5 Volt.

Miscellaneous

Settings

One-Time Boot attribute=MemTest attribute=NodeInterleave attribute=SerialDbgOut attribute=SysMemSize attribute=SysMemSpeed attribute=SysMemType attribute=SysMemVolt attribute=VideoMem attribute=AssetTag attribute=Characterization attribute=ErrPrompt attribute=NumLock attribute=ReportKbdErr attribute=SystemUefiShell attribute=OneTimeBootMode setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled setting=<string> setting=<string> setting=<string> setting=<string> setting=<string> setting=<string> setting=Enabled | Disabled setting=Enabled | Disabled setting=On | Off setting=Report | NoReport setting=Enabled | Disabled setting=Disabled | OneTimeBootSeq |

OneTimeHddSeq | OneTimeUefiBootSeq |

OneTimeCustomBootSeqStr |

OneTimeCustomHddSeqStr |

OneTimeCustomUefiBootSeqStr attribute=OneTimeBootSeqDev sequence=aliasname1, aliasname2,..... aliasnameN attribute=OneTimeHddSeqDev sequence=aliasname1, aliasname2,..... aliasnameN attribute=OneTimeUefiBootSeq

Dev sequence=aliasname1, aliasname2,..... aliasnameN

78

Group

Processor

Settings name=value pair 1 attribute= attribute=DataReuse name=value pair 2 setting= setting=Enabled | Disabled attribute=DcuIpPrefetcher attribute=DcuStreamerPrefetch er attribute=LogicalProc attribute=Proc1Brand attribute=Proc1Id attribute=Proc1L2Cache attribute=Proc1L3Cache attribute=Proc1NumCores attribute=Proc2Brand attribute=Proc2Id attribute=Proc2L2Cache attribute=Proc2L3Cache attribute=Proc2NumCores attribute=Proc3Brand attribute=Proc3Id attribute=Proc3L2Cache attribute=Proc3L3Cache attribute=Proc3NumCores attribute=Proc4Brand attribute=Proc4Id attribute=Proc4L2Cache attribute=Proc4L3Cache attribute=Proc4NumCores attribute=Proc64bit attribute=ProcAdjCacheLine attribute=ProcBusSpeed attribute=ProcCores attribute=ProcCoreSpeed attribute=ProcExecuteDisable setting=Enabled | Disabled setting=Enabled | Disabled setting=Enabled | Disabled setting=<string> setting=<string> setting=<string> setting=<string> setting=<integer> setting=<string> setting=<string> setting=<string> setting=<string> setting=<integer> setting=<string> setting=<string> setting=<string> setting=<string> setting=<integer> setting=<string> setting=<string> setting=<string> setting=<string> setting=<integer> setting=<string> setting=Enabled | Disabled setting=<string> setting=Single | All | Dual | Quad | 1 | 2 | 4 | 6 | 8 |

10 | 12 | 14 | 16 setting=<string> setting=Enabled | Disabled

79

Group name=value pair 1 attribute= attribute=ProcHwPrefetcher name=value pair 2 setting= setting=Enabled | Disabled attribute=ProcVirtualization setting=Enabled | Disabled attribute=QpiBandwidthPriority setting=InputOutput | Compute attribute=QpiSpeed attribute=RtidSetting setting=MaxDataRate | 8GTps | 7GTps | 6GTps setting=Enabled | Disabled attribute=EmbSata attribute=eSataPort1 setting=Off | AtaMode | RaidMode | AhciMode setting=Off | Auto attribute=eSataPort1Capacity setting=<string> attribute=eSataPort1DriveType setting=<string> attribute=eSataPort1Model attribute=SataPortA attribute=SataPortACapacity attribute=SataPortADriveType attribute=SataPortAModel attribute=SataPortB attribute=SataPortBCapacity attribute=SataPortBDriveType setting=<string> setting=Off | Auto setting=<string> setting=<string> setting=<string> setting=Off | Auto setting=<string> setting=<string> attribute=SataPortBModel attribute=SataPortC attribute=SataPortCCapacity attribute=SataPortCDriveType attribute=SataPortCModel attribute=SataPortD attribute=SataPortDCapacity attribute=SataPortDDriveType attribute=SataPortDModel attribute=SataPortE attribute=SataPortECapacity attribute=SataPortEDriveType attribute=SataPortEModel attribute=SataPortF attribute=SataPortFCapacity setting=<string> setting=Off | Auto setting=<string> setting=<string> setting=<string> setting=Off | Auto setting=<string> setting=<string> setting=<string> setting=Off | Auto setting=<string> setting=<string> setting=<string> setting=Off | Auto setting=<string>

80

Group name=value pair 1 attribute= attribute=SataPortFDriveType attribute=SataPortFModel attribute=SataPortG attribute=SataPortGCapacity attribute=SataPortGDriveType attribute=SataPortGModel attribute=SataPortH attribute=SataPortHCapacity attribute=SataPortHDriveType attribute=SataPortHModel attribute=ConTermType name=value pair 2 setting= setting=<string> setting=<string> setting=Off | Auto setting=<string> setting=<string> setting=<string> setting=Off | Auto setting=<string> setting=<string> setting=<string> setting=Vt100Vt220 | Ansi Serial

Communication attribute=ExtSerialConnector attribute=FailSafeBaud attribute=RedirAfterBoot attribute=SerialComm attribute=SerialPortAddress

Slot Disablement attribute=Slot1 attribute=Slot2 attribute=Slot3 attribute=Slot4

System

Information attribute=Slot5 attribute=Slot6 attribute=Slot7 attribute=SysMfrContactInfo

System Profile

Settings setting=Serial1 | Serial2 | RemoteAccDevice setting=115200 | 57600 | 19200 | 9600 setting=Enabled | Disabled setting=OnNoConRedir | OnConRedirCom1 |

OnConRedirCom2 | Off setting=Serial1Com1Serial2Com2 |

Serial1Com2Serial2Com1 | Com1 | Com2 setting=Enabled | Disabled | BootDriverDisabled setting=Enabled | Disabled | BootDriverDisabled setting=Enabled | Disabled | BootDriverDisabled setting=Enabled | Disabled | BootDriverDisabled setting=Enabled | Disabled | BootDriverDisabled setting=Enabled | Disabled | BootDriverDisabled setting=Enabled | Disabled | BootDriverDisabled setting=<string> attribute=SystemBiosVersion setting=<string> attribute=SystemManufacturer setting=<string> attribute=SystemModelName attribute=SystemServiceTag attribute=MemFrequency setting=<string> setting=<string> setting=MaxPerf | 1600MHz | 1333MHz |1067MHz

| 800MHz | MaxReliability

81

Group name=value pair 1 attribute= attribute=MemPatrolScrub attribute=MemRefreshRate attribute=MemVolt name=value pair 2 setting= setting=Standard | Extended | Disabled setting=1x | 2x setting=AutoVolt | Volt15V | Volt135V

NOTE: Volt15V represents 1.5 Volt and

Volt135V represents 1.35 Volt attribute=ProcC1E attribute=ProcCStates attribute=ProcPwrPerf attribute=ProcTurboMode attribute=SysProfile setting=Enabled | Disabled setting=Enabled | Disabled setting=MaxPerf | MinPwr | SysDbpm | OsDbpm setting=Enabled | Disabled setting=PerfPerWattOptimizedOs |

PerfPerWattOptimizedDapc | PerfOptimized |

Custom | DenseCfgOptimized

System Security attribute=AcPwrRcvry attribute=AcPwrRcvryDelay setting=On | Off | Last setting=Immediate | User | Random attribute=AcPwrRcvryUserDelay setting=<integer> attribute=AesNi setting=Enabled | Disabled attribute=BiosUpdateControl attribute=IntelTxt attribute=NmiButton attribute=PasswordStatus attribute=PwrButton attribute=SetupPassword attribute=SysPassword attribute=TcmActivation attribute=TcmClear setting=Unlocked | Limited | Locked setting=On | Off setting=Enabled | Disabled setting=Locked | Unlocked setting=Enabled | Disabled setting=<string> setting=<string> setting=NoChange | Activate | Deactivate

CAUTION: Clearing the TCM will cause loss of all keys in the TCM. This could affect booting of the operating system.

attribute=TcmSecurity attribute=TpmActivation attribute=TpmClear setting=Yes | No setting=On | Off setting=NoChange | Activate | Deactivate

CAUTION: Clearing the TPM will cause loss of all keys in the TPM. This could affect booting of the operating system.

setting=Yes | No

82

Group name=value pair 1 attribute= attribute=TpmSecurity attribute=UefiBootSeq name=value pair 2 setting= setting=Off | OnPbm | OnNoPbm sequence=aliasname1, aliasname2,..... aliasnameN UEFI Boot

Settings

Omconfig Chassis Currents Or Omconfig Mainsystem Currents

NOTE: This command is no longer available through Server Administrator.

Omconfig Chassis Fans Or Omconfig Mainsystem Fans

Use the omconfig chassis fans or omconfig mainsystem fans command to set fan probe warning thresholds. As with other components, you can view both warning and failure threshold values, but you cannot set failure thresholds. The system manufacturer sets the minimum and maximum failure thresholds.

Valid Parameters For Fan Warning Thresholds

The following table shows the valid parameters for setting fan warning thresholds:

Table 23. omconfig chassis fans or omconfig chassis fans name=value pair index= <n> warnthresh=default minwarnthresh=<n> maxwarnthresh=<n>

Description

Number of the probe or probe index (must specify).

Sets minimum and maximum warning thresholds to default.

Minimum warning threshold.

Maximum warning threshold.

Default Minimum And Maximum Warning Thresholds

NOTE: Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to set warning threshold values to default values.

To set both the upper and lower fan warning threshold values to the recommended default value, type: omconfig chassis fans index=0 warnthresh=default or omconfig mainsystem fans index=0 warnthresh=default

You cannot default one value and set another. In other words, if you default the minimum warning threshold value, you are also selecting the default value for the maximum warning threshold value.

Specifying A Value For Minimum And Maximum Warning Thresholds

If you prefer to specify values for the fan probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values. In the following

83

example, the probe that is being configured is probe 0. The first command sets only the minimum threshold; the second sets the minimum and maximum thresholds: omconfig chassis fans index=0 minwarnthresh=4580 or omconfig mainsystem fans index=0 minwarnthresh=4580 omconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160 or omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160

When you issue the command and the system sets the values you specify, the following message is displayed:

Fan probe warning threshold(s) set successfully.

NOTE: You cannot set the minimum and maximum warning thresholds for the fan probe on

PowerEdge 9G system.

Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel

Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to:

• configure the power button and the Nonmasking Interrupt (NMI) button

• configure the LCD to display:

– No information

– Custom information

– Default system information

– Service tag, system name

– Remote access MAC addresses

– System power

– Remote access IP address

– Ambient temperature of the system

– Remote access IPv4 address

– Remote access IPv6 address

• Specify and configure the LCD line number

• View the encryption state report of the LCD

• Configure LCD to indicate an active remote session when the Kernel-based Virtual Machine (KVM) is available

NOTE: You can configure the Power and NMI buttons only if they are present on the system.

The following table displays the valid parameters for the command:

84

Table 24. Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel name=value pair 1 lcdindex=<index> config=none | default | custom name=value pair 2

NA

NA

Description

Specifies the LCD line number.

• none: Sets the LCD text to none.

• default: Sets the LCD text to default.

• custom: Sets the LCD text to custom.

text=<custom text> nmibutton=enable | disable powerbutton=enable | disable

NA

NA

NA

Sets the custom text for LCD when config=custom.

• enable: Enables the NMI button on the system.

• disable: Disables the NMI button on the system.

• true: Enables the Power button on the system.

• false: Disables the Power button on the system.

config=sysname config=syspower config=servicetag config=remoteaccessip v4 config=remoteaccessip v6 config=remoteaccessm ac

NA

NA config=ipv4idrac config=ipv6idrac config=macidrac config=ambienttemp security=modify security=view security=disabled NA remoteindication=true NA

NA

NA

NA

NA

NA

NA

NA

NA

Sets the name of the system.

Sets the system power information.

Sets the system service tag information.

Sets the remote access IPv4 information.

Sets the remote access IPv6 information.

Sets the remote access MAC address.

Sets IPv4 DRAC information.

Sets IPv6 DRAC information.

Sets the DRAC’s MAC address.

Sets the system temperature in centigrade.

Allows you to modify the LCD text.

Provides read-only access to the LCD text.

Provides limited access to the LCD text.

LCD flashes when the system detects an active remote session.

NOTE: The options ipv4idrac, ipv6idrac, and macidrac are deprecated.

Omconfig Chassis Info Or Omconfig Mainsystem Info

Use the omconfig chassis info or omconfig mainsystem info command to enter an asset tag name and a chassis name for the system. For a blade systems, enter asset tag names for modular components as well.

The following table displays the valid parameters for the command:

85

Table 25. Valid Parameters Of Omconfig Chassis Info Or Omconfig Mainsystem Info name=value pair index=<n> tag=<text> name=<text>

Description

Number of the chassis whose asset tag or name you are setting.

Asset tag in the form of alphanumeric text. Letters or numbers should not exceed

10 characters.

Name of the chassis.

In the following example, the asset tag for the main system chassis is being set to buildsys: omconfig chassis info index=0 tag=buildsys or omconfig mainsystem info index=0 tag=buildsys

Index 0 always defaults to the main system chassis. The following command omits index=n, but accomplishes the same: omconfig chassis info tag=buildsys or omconfig mainsystem info tag=buildsys

An acceptable command, when executed, results in the following message:

Chassis info set successfully.

For some chassis, you can assign a different name. You cannot rename the main system chassis. In the following example, the command renames chassis 2 from storscsi1 to storscsia: omconfig chassis info index=2 name=storscsia or omconfig mainsystem info index=2 name=storscsia

As with other commands, the CLI issues an error message if you do not have a chassis 2 (the main chassis=0). The CLI allows you to issue commands only for the system configuration you have.

Omconfig Chassis Leds Or Omconfig Mainsystem Leds

Use the omconfig chassis leds or omconfig mainsystem leds command to specify when to flash a chassis fault LED or chassis identification LED. This command also allows you to clear the LED of the system hard drive. The following table displays the valid parameters for the command.

Table 26. Valid Parameters Of Omconfig Chassis Leds Or Omconfig Mainsystem Leds name=value pair 1 name=value pair 2 index=<n> NA led=fault led=hdfault severity=warning | critical action=clear

Description

Number of the chassis where the LED resides

(defaults to chassis 0, main system chassis).

Select to flash the LED either when a warning event occurs or when a critical event occurs.

Sets the number of faults for the hard drive back to zero (0).

86

name=value pair 1 name=value pair 2 led=identify flash=off | on time-out=<n>

Description

Sets the chassis identification LED to off or on.

Set the time-out value for the LED to flash to a number of seconds.

Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode

Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify the redundancy mode to use for the system memory in case of memory errors.

Redundant memory enables a system to switch to other available memory modules if unacceptable errors are detected in the modules that the system is currently using. The omconfig chassis memorymode or omconfig mainsystem memorymode command allows you to disable redundancy; when you disable redundancy, you instruct the system not to switch to other available memory modules when the memory module the system is using begins to encounter errors. To enable redundancy, choose among spare, mirror, raid, and DDDC.

Spare mode disables a bank of system memory in which a correctable memory event is detected, enables the spare bank, and copies all the data from the original bank to the spare bank. Spare bank requires at least three banks of identical memory; the operating system does not recognize the spare bank.

Mirror mode switches to a redundant copy of memory when an uncorrectable memory event is detected.

After switching to the mirrored memory, the system does not switch back to the original system memory until the next reboot. The operating system does not recognize half of the installed system memory in this mode.

RAID mode provides an extra level of memory checking and error recovery at the expense of some memory capacity.

The DDDC mode enables double device data correction. This ensures data availability after hard failure of x4 DRAM.

NOTE: This command is applicable only on systems prior to PowerEdge 12G systems. On

PowerEdge 12G systems, memorymode is grouped under Memory Settings of the BIOS setup

group. For more information, see BIOS Setup Groups on PowerEdge 12G Systems .

To configure the attribute on systems prior to PowerEdge 12G, see the following table. The table displays the valid parameters for the command.

Table 27. Valid Parameters Of Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode name=value pair 1 index=<n>

Description

Number of the chassis where the memory module resides (the default is chassis 0, the main system chassis).

redundancy=spare | mirror | disabled | raid5 | dddc spare: Disables the memory module that has a correctable memory event and copies the failing module’s data to a spare bank.

mirror: Switches the systems to a mirrored copy of the memory if the failing module has an

87

name=value pair 1 opmode=mirror | optimizer | advecc

Description uncorrectable memory event. In the mirror mode, the operating system does not switch back to the original module until the system reboot.

disabled: Indicates that the system is not to use other available memory modules if uncorrectable memory events are detected.

raid5: Method of system memory configuration.

This is logically similar to the RAID-5 mode used in hard drive storage systems. This memory mode provides an extra level of memory checking and error recovery at the expense of some memory capacity. The RAID mode supported is RAID level 5 striping with rotational parity.

dddc: The dddc mode enables double device data correction. This ensures data availability after hard failure of x4 DRAM.

mirror: Switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event. In the mirror mode, the operating system does not switch back to the original module until the system reboots.

optimizer: Enables the DRAM controllers to operate independently in 64-bit mode and provide optimized memory performance.

advanced ECC (advecc): Enables the two DRAM controllers to combine in 128-bit mode and provide optimized reliability. Memory that are not teamed by the controllers is not reported to the operating system.

Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem

Pwrmanagement

Use the omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement command to configure power cap and manage profiles that control power utilization.

NOTE: This command is valid only on systems prior to PowerEdge 12G systems.

The following table displays the valid parameters for the command:

Table 28. Valid Parameters Of Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem

Pwrmanagement name=value pair 1 config=budget name=value pair 2 cap=<value>

Description

Sets the threshold value for power budget.

88

name=value pair 1 name=value pair 2 setting=enable | disable cpupowermode=min | max | systemdbpm | osdbpm

Description

NOTE: From PowerEdge

12G system onwards, power budget requires license to configure power cap. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License

Manager at dell.com/ support/manuals.

enable: Enables powercap settings.

disable: Disables powercap settings.

unit=watt | btuphr | percent config=profile

NOTE: This option is supported on systems prior to PowerEdge 12G systems.

profile=maxperformance | apc | osctrl | custom watt: Configure the unit in Watts.

btuphr: Configure the unit in

BTU/hr.

percent: Configure the unit in percentage.

maxperformance: Sets the processor to the highest supported processor state. It offers maximum performance mode with minimal power economy.

apc: Active Power Control (apc) enables the demand-based power management controlled by BIOS.

osctrl: OS Control (osctrl) enables the demand-based power management controlled by the operating system.

custom: This profile allows you to configure individual BIOS settings. It offers added control by displaying the underlying BIOS settings.

min: Sets the CPU power consumption to minimum.

max: Sets the CPU power consumption to maximum.

89

name=value pair 1 name=value pair 2 Description systemdbpm: Sets the mode to system demand based power management.

osdbpm: Sets the mode to operating system demand based power management.

NOTE: These options are applicable only when a custom profile is selected.

memorypowermode=min | 800 |

1067 | 1333 | max min: Sets the mode to minimum power utilization.

800 | 1067 | 1333: Set the mode to 800, 1067, or 1333 MHz.

max: Sets the mode to maximum performance.

NOTE: These options are applicable only when a custom profile is selected.

fanmode=min | max min: Sets the fanmode to minimum power utilization.

max: Sets the fanmode to maximum power utilization.

NOTE: These options are applicable only when a custom profile is selected.

NOTE: Reboot the system for the power profiles setup options to take effect.

Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring

Use the omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring command to configure power consumption information.

The following table displays the valid parameters for the command:

Table 29. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring name=value pair 1 index=<n> config=probe name=value pair 2

NA warnthresh=settodefault

Description

Number of the probe or probe index (must specify).

Sets the minimum and maximum warning thresholds values to default.

90

name=value pair 1 config=resetreading name=value pair 2 warnthresh=<n > unit=watt | btuphr type=energy | peakpower

Description

Sets a value for the warning threshold.

watt: Displays the unit in Watts.

btuphr: Displays the unit in

BTU/hr.

energy: Resets the system energy reading.

peakpower: Resets the system peak power.

NOTE: This command is applicable only on selected Dell 10G systems that support PMBus.

NOTE: Power monitoring requires license to configure the power budget information. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License Manager at dell.com/openmanagemanuals.

Default Warning Thresholds

NOTE: Sensor managing capabilities vary across systems.

To set both the upper and lower power consumption probe warning threshold values to the recommended default value, type: omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefault or omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault

You cannot default one value and set another. If you default the minimum warning threshold value, you are also selecting the default value for the maximum warning threshold value.

Specify A Value For Warning Thresholds

If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the probe you are configuring and the warning threshold value. Configure the values to display either in BTU/hr or Watts. In the following example, the probe that is being configured is probe 4: omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt or omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325 unit=btuphr

When you issue the command and the system sets the values you specify, the following message is displayed:

Power consumption probe warning threshold(s) set successfully.

Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess

Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to configure:

91

• Remote access on a local area network (LAN).

• The serial port for BMC or RAC, whichever is installed.

• The BMC or RAC on a serial over LAN connection.

• Terminal settings for the serial port.

• Advanced settings for a serial over LAN connection.

• Information on a BMC or RAC user.

• Information on IPv6 and IPv4 interfaces.

NOTE: Enter the user ID to configure user information.

Type: omconfig chassis remoteaccess or omconfig mainsystem remoteaccess

The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the available configurations. The following table displays the valid parameters:

Table 30. Valid Parameters Of Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess name=value pair 2 Description name=value pair 1 config= config=additional ipv4=enable | disable enable: IPv4 stack to load on iDRAC.

disable: IPv4 stack to flush on iDRAC.

ipv6=enable | disable enable: Enables IPv6 stack to load on iDRAC.

disable: Disables IPv6 stack to unload on iDRAC.

NOTE: This option requires license to enable or disable ipv6. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License

Manager at dell.com/ openmanagemanuals.

config=advsol characcuminterval=number charsendthreshold=number enableipmi= true | false enablenic=true | false number: Sets the character accumulate interval in 5 millisecond intervals.

number: Sets the number of characters. BMC automatically sends a serial over LAN data packet that contains the number of characters as soon as this number of characters (or greater) has been accepted from the baseboard serial controller into the BMC.

true: Enables IPMI over LAN.

false: Disables IPMI over LAN.

true: Enables DRAC NIC.

92

name=value pair 1 config= name=value pair 2 Description false: Disables DRAC NIC

NOTE: The enablenic option is supported on PowerEdge 9G systems that have

DRAC 5 installed.

nicselection=sharedwithfailover onall | nic1 |teamednic1nic2 | dracnic sharedwithfailoveronall: Configures the new

NIC selection option.

nic1: Enables NIC 1.

teamednic1nic2: Enables NIC teaming functionality.

dracnic: Enables DRAC NIC if DRAC 5 is installed.

NOTE: The nicselection option is supported only on PowerEdge 9G to 11G systems. From PowerEdge 12G systems onwards, primarynw and failovernw replaces nicselection.

primarynw=dedicated | lom1 | lom2 | lom3 | lom4 dedicated: Configures dedicated port as primary network for remote access.

NOTE: This option requires license to configure primarynw as dedicated. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell

License Manager at dell.com/ openmanagemanuals.

lom 1: Configures lom1 port as the primary network for remote access.

lom 2: Configures lom2 port as the primary network for remote access.

lom 3: Configures lom3 port as the primary network for remote access.

lom 4: Configures lom4 port as the primary network for remote access.

NOTE: The primarynw option is supported from PowerEdge12G systems onward. If the primarynw is set to dedicated, then set failovernw to none.

failovernw=none | lom1 | lom2 | lom3 | lom4 | all none: Configures the failover network to none.

lom 1:Configures the failover network to lom 1.

lom 2: Configures the failover network to lom

2.

93

name=value pair 1 config= name=value pair 2 ipaddress=IP subnet=Subnet gateway=Gateway ipsource=static | dhcp | systemsoftware ipaddressv6=<IPv6 address> prefixlength= length gatewayv6=<value> ipsourcev6=static | auto

Description lom 3: Configures the failover network to lom

3.

lom 4: Configures the failover network to lom

4.

all: Configures the failover network to all loms.

NOTE: The failovernw option is supported on PowerEdge12G systems onward.

Configure both primarynw and failovernw to set the nicselection. The primarynw and failovernw options cannot have the same value.

NOTE: Failovernw requires license to configure the ports. If the appropriate license is not installed or has expired, the system displays an error message. For more information, see Dell License

Manager at dell.com/ openmanagemanuals.

Sets the IP address if you have selected static as the IP address source for the BMC LAN interface.

Sets a subnet mask if you have selected static as the IP address source for the BMC LAN interface.

Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface.

static: Static if the IP address of the BMC LAN interface is a fixed, assigned IP address.

dhcp: DHCP if the source of the IP address of the BMC LAN interface is the dynamic host configuration protocol.

systemsoftware: System software if the source of the IP address of the BMC LAN interface is from the system software.

NOTE: All commands may not be supported on the system.

Validates the IPv6 address for configuration.

Validates the IPv6 gateway.

static: IPv6 address source is set to static.

94

name=value pair 1 config= name=value pair 2 config=serial

Description altdnsserverv6 dnssourcev6=static | auto vlanenable=true | false vlanid=number vlanpriority=number privilegelevel=administrator | operator | user encryptkey=text confirmencryptkey=text auto: IPv6 address source is set to auto.

Validates the address of the alternate DNS server for configuration.

static: DNS source is set to static.

auto: DNS source is set to auto.

true: Enables the virtual LAN identification.

false: Disables the virtual LAN identification.

number: Virtual LAN identification in the range of 1 to 4094.

number: Priority of virtual LAN identification in the range of 0 to 7.

administrator: Sets the maximum privilege level that is accepted on a LAN channel, to

Administrator.

operator: Sets the maximum privilege level that is accepted on a LAN channel, to

Operator.

user: Sets the maximum privilege level that is accepted on a LAN channel, to User.

text: Text used for encryption and confirmation of encryption.

NOTE: The text option is supported only on PowerEdge 9G systems.

prefdnsserverv6=<value> baudrate=9600 | 19200 | 38400

| 57600 | 115200

Validates the preferred DNS server for configuration.

9600: Sets the connection speed to 9600 bits per second.

19200: Sets the connection speed to 19200 bits per second.

NOTE: Baud rates of 9600 and 19200 are supported on PowerEdge 1800, 1850,

2800, and 2850 systems.

38400: Sets the volatile and non-volatile connection speed to 38400 bits per second.

57600: Sets the volatile and non-volatile connection speed to 57600 bits per second.

95

name=value pair 1 config= name=value pair 2 Description privilegelevel=administrator | operator | user

NOTE: Baud rates of 19200, 38400, and

57600 are supported on PowerEdge 9G systems.

115200: Sets the volatile and non-volatile connection speed to 115200 bits per second.

NOTE: Baud rate of 115200 is supported on certain systems that have a DRAC 5 installed.

NOTE: Baud rate of 19200, 57600, and

115200 are supported on 10G systems that have iDRAC installed.

flowcontrol=none | rtscts none: No control over the flow of communication through the serial port.

rtscts: RTS is ready to send and CTS is clear to send.

mode=directbasic | directterminal | directbasicterminal | modembasic | modemterminal | modembasicterminal directbasic: Type of messaging used for IPMI messaging over a serial connection.

directterminal: Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a serial connection.

directbasicterminal: Both basic and terminal mode messaging over a serial connection.

modembasic: Type of messaging used for IPMI messaging over a modem.

modemterminal: Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a modem.

modembasicterminal: Both basic and terminal messaging over a modem.

NOTE: All commands may not be supported on the system.

administrator: Sets the maximum privilege level that are accepted on a serial connection, to Administrator.

operator: Sets the maximum privilege level that are accepted on a serial connection, to

Operator.

user: Sets the maximum privilege level that are accepted on a serial connection, to User.

96

name=value pair 1 config= name=value pair 2 config=serialoverlan enable=true | false

Description true: Enables serial over LAN for the BMC.

false: Disables serial over LAN for the BMC.

baudrate=9600 | 19200 | 38400

| 57600 | 115200

9600: Sets the volatile and nonvolatile connection speed to 9600 bits per second.

19200: Sets the volatile and non-volatile connection speed to 19200 bits per second.

NOTE: Baud rates of 9600 and 19200 are supported on PowerEdge 1800, 1850,

2800, and 2850 systems.

38400: Sets the volatile and non-volatile connection speed to 38400 bits per second.

57600: Sets the volatile and non-volatile connection speed to 57600 bits per second.

NOTE: Baud rates of 19200, and 57600 are supported on PowerEdge 9G systems.

115200: Sets the volatile and non-volatile connection speed to 115200 bits per second.

NOTE: Baud rate of 115200 is supported on certain systems that have a DRAC 5 installed.

NOTE: Baud rate of 19200, 57600, and

115200 are supported on 10G systems that have iDRAC installed.

privilegelevel=administrator | operator | user administrator: Sets the maximum privilege level that are accepted on a serial over LAN channel, to Administrator.

operator: Sets the maximum privilege level that are accepted on a serial over LAN channel, to Operator.

user: Sets the maximum privilege level that are accepted on a serial over LAN channel, to User.

config=settodefault config=terminalmo de deletecontrol=outputdel | outputbkspspbksp handshakingcontrol=enabled | disabled

Takes the default configuration settings.

utputdel: BMC outputs a <del> character when

<bksp> or <del> is received.

outputbkspspbksp: BMC outputs a

<bksp><sp><bksp> character when <bksp> or

<del> is received.

enabled: Directs the BMC to output a character sequence that indicates when its

97

name=value pair 1 config= name=value pair 2 config=user

Description inputlinesequence=cr | null lineediting=enabled | disabled newlinesequence=none| crlf | null | cr | lfcr | lf id=number enable=true | false id=number enableserialoverlan=true | false input buffer is ready to accept another command.

disabled: Does not direct the BMC to output a character sequence that indicates when its input buffer is ready to accept another command.

cr: The console uses <CR> as a new line sequence.

null: The console uses <NULL> as a new line sequence.

enabled: Enables line editing as a line is typed.

disabled: Disables line editing as a line is typed.

none: BMC does not use a termination sequence.

crlf: BMC uses <CR-LF> as a new line sequence when the BMC writes a new line to the console.

null: BMC uses <Null> as a new line sequence when the BMC writes a new line to the console.

cr: BMC uses <CR> as a new line sequence when the BMC writes a new line to the console.

lfcr: BMC uses <LF-CR> as a new line sequence when the BMC writes a new line to the console.

lf: BMC uses <LF> as a new line sequence when the BMC writes a new line to the console.

id=number: ID (in numeric format) of the user being configured.

enable=true: Enables the user.

enable=false: Disables the user.

id=number: ID (in numeric format) of the user being configured.

enableserialoverlan=true: Enables serial over

LAN.

98

name=value pair 1 config= name=value pair 2 Description id=number name=text id=number lanaccesslevel=administrator | operator | user| none enableserialoverlan=false: Disables serial over

LAN.

NOTE: The enableserialoverlan option is supported only on PowerEdge 9G systems.

id=number: ID (in numeric format) of the user being configured.

name=text: Name of the user.

id=number newpw=text confirmnewpw=text id=number: ID (in numeric format) of the user being configured.

newpw=text: New password of the user.

confirmnewpw=text: Confirm the new password.

id=number serialaccesslevel=administrator | operator | user | none id=number: ID (in numeric format) of the user being configured.

serialaccesslevel=administrator: User with an

ID has access privileges of an Administrator for the serial port channel.

serialaccesslevel=operator: User with an ID has access privileges of an Operator for the serial port channel.

serialaccesslevel=user: User with an ID has access privileges of a User for the serial port channel.

serialaccesslevel=none: User with an ID does not have access privileges for the serial port channel.

id=number: ID number of the user being configured.

lanaccesslevel=administrator: User with an ID has access privileges of an Administrator for the LAN channel.

lanaccesslevel=operator: User with an ID has access privileges of an Operator for the LAN channel.

lanaccesslevel=user: User with an ID has access privileges of a user for the LAN channel.

lanaccesslevel=none: User with an ID does not have access privileges for the LAN channel.

99

name=value pair 1 config= name=value pair 2 Description id=user id dracusergroup=admin

| poweruser | guest | custom | none id=user id: User ID of the user being configured.

dracusergroup=admin: Enables the

Administrator user privileges.

dracusergroup=poweruser: Enables the Power

User privileges.

dracusergroup=guest: Enables the Guest user privileges.

dracusergroup=custom: Enables the Custom

User privileges.

NOTE: For more information on

dracusergroup=custom, see Usage of

Dracusergroup=custom .

dracusergroup=none: Does not enable user privileges.

id=user id extipmiusergroup=admin | operator | readonly | custom | none

NOTE: extipmiusergroup user group is available only on Dell yx0x blade systems.

id=user id: User ID of the user being configured.

extipmiusergroup=admin: Enables the

Administrator user privileges.

extipmiusergroup=operator: Enables the

Operator privileges.

extipmiusergroup=readonly: Enables the Read

Only privileges.

extipmiusergroup=custom: Enables the

Custom User privileges.

NOTE: It is recommended that you use the operator and readonly options for systems with iDRAC Enterprise. For more

information, see Usage of

Extipmiusergroup=custom

.

extipmiusergroup=none: Does not enable user privileges.

Usage Of Dracusergroup=custom

The following table displays the usage of dracusergroup=custom.

100

Table 31. Valid Parameters of omconfig chassis remoteaccess config=user id=<user id> dracusergroup=custom or omconfig mainsystem remoteaccess config=user id=<user id> dracusergroup=custom name=value pair 3 Description name=valu e pair 1 name=value pair 2 config=user id=user id dracusergroup=custo m logindrac=true | false true or false: Enables or disables logging into DRAC.

configuredrac=true | false true or false: Enables or disables configuration of DRAC.

configure users=true | false clearlogs=true | false true or false: Enables or disables configuration of users.

true or false: Enables or disables log clearance.

executeservercommands=tru e | false true or false: Enables or disables execution of server commands.

accessconsoleredir=true | false true or false: Enables or disables access to console redirection.

accessvirtualmedia=true | false testalerts=true | false true or false: Enables or disables access to virtual media.

true or false: Enables or disables test alerts.

Usage of Extipmiusergroup=custom

The following table displays the usage of extipmiusergroup=custom:

Table 32. Usage Of extipmiusergroup=custom name=value pair 1 config=user name=value pair 2 id=user id extipmiusergroup=custo m

NOTE: extipmiusergroup user group is available only on the Dell10G blade systems.

name=value pair 3 loginidrac=true | false configureidrac=true | false

Description true or false: Enables or disables logging into iDRAC.

true or false: Enables or disables configuration of iDRAC.

101

Omconfig Chassis Temps Or Omconfig Mainsystem Temps

Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for temperature probes. As with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. The system manufacturer sets the minimum and maximum failure threshold values.

NOTE: Threshold values that you can set vary from one system configuration to another.

Valid Parameters For Temperature Warning Thresholds

The following table displays the valid parameters for setting temperature warning thresholds:

Table 33. Valid Parameters For Omconfig Chassis Temps Or Omconfig Mainsystem Temps name=value pair index=<n> warnthresh=default minwarnthresh=<n> maxwarnthresh=<n>

Description

Number of the probe or probe index (specify).

Sets the minimum and maximum warning threshold values to default.

Sets the minimum warning threshold values (one decimal place).

Sets the maximum warning threshold values (one decimal place).

Setting Minimum And Maximum Warning Threshold Values

To set both the upper and lower temperature warning threshold values to the recommended default value, type: omconfig chassis temps index=0 warnthresh=default or omconfig mainsystem temps index=0 warnthresh=default

You cannot default one value and set another. In other words, if you set the minimum warning threshold value to the default value, you are also selecting the default value for the maximum warning threshold value.

NOTE: The capabilities for managing sensors vary by systems.

Specify A Value For Minimum And Maximum Warning Thresholds

To specify values for the temperature probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold value. In the following example, the probe that is being configured is probe 4: omconfig chassis temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7

or omconfig mainsystem temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7

When you issue the command and the system sets the values you specify, the following message is displayed:

Temperature probe warning threshold(s) set successfully.

102

NOTE: On PowerEdge 9G system, you can set the temperature probe warning threshold only for ambient temperature.

Omconfig Chassis Volts Or Omconfig Mainsystem Volts

Use the omconfig chassis volts or omconfig mainsystem volts command to set voltage probe warning thresholds. As with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. The system manufacturer sets the minimum and maximum values for the failure thresholds.

Valid Parameters For Voltage Warning Thresholds

The following table displays the valid parameters for setting voltage warning threshold values.

NOTE: Threshold values that you can set vary from one system configuration to another.

Table 34. Valid Parameters Of Omconfig Chassis Volts Or Omconfig Mainsystem Volts name=value pair index=<n> warnthresh=default minwarnthresh=<n> maxwarnthresh=<n>

Description

Probe index (specify).

Sets minimum and maximum warning threshold values to default.

Sets minimum warning threshold value (three decimal places).

Sets maximum warning threshold value (three decimal places).

Specify A Value For Minimum And Maximum Warning Thresholds

To specify values for the voltage probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values.

In the following example, the probe being configured is probe 0: omconfig chassis volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250

or omconfig mainsystem volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250

When you issue the command and the system sets the values you specify, the following message is displayed:

Voltage probe warning threshold(s) set successfully.

Omconfig Preferences

Use the omconfig preferences command to set system preferences. Use the command line to specify the user levels to access Server Administrator and to configure the Active Directory service.

Omconfig Preferences Cdvformat

Use the omconfig preferences cdvformat to specify the delimiters for separating data fields reported in the custom delimited format. The valid values for delimiters are: exclamation, semicolon, at, hash, dollar, percent, caret, asterisk, tilde, question, colon, comma, and pipe.

103

The following example shows how to set the delimiter for separating data fields to asterisk: omconfig preferences cdvformat delimiter=asterisk

Omconfig Preferences Dirservice

Use the omconfig preferences dirservice command to configure the Active Directory service. The

<productname>oem.ini file is modified to reflect these changes. If the "adproductname" is not present in the <productname>oem.ini file then a <computername>-<computername> refers to the name of the computer running Server Administrator and <productname> refers to the name of the product defined in omprv32.ini. For Server Administrator, the product name is "omsa".

Therefore, for a computer named "myOmsa" running Server Administrator, the default name is

"myOmsa–omsa". This is the name of Server Administrator defined in Active Directory by using the snapin tool. This name must match the name for the application object in Active Directory in order to find user privileges.

NOTE: This command is applicable only on systems running the Windows operating system.

The following table displays the valid parameters for the command:

Table 35. Valid Parameters Of Omconfig Preferences Dirservice name=value pair Description prodname=<text> Specifies the product to which you want to apply the Active Directory configuration changes. prodname refers to the name of the product defined in omprv32.ini. For

Server Administrator, it is "omsa".

enable=<true | false> true: Enables Active Directory service authentication support and the Active

Directory Login option on the login page.

false: Disables Active Directory service authentication support and the Active

Directory Login option on the login page. If the Active Directory Login option is not present, you can only login to the local machine accounts.

adprodname=<tex t>

Specifies the name of the product as defined in the Active Directory service. This name links the product with the Active Directory privilege data for user authentication.

Omconfig Preferences Messages

Use the omconfig preferences messages command to select the format of alert messages. The default format is traditional, which is the legacy format.

The following table lists the parameters you can use with this command.

Table 36. Valid Parameters Of Configuring Preferences Messages name=value pair 1 name=value pair 2 attribute=format setting=traditional | enhanced

Description traditional: Sets the alert message to traditional format.

104

name=value pair 1 name=value pair 2 Description enhanced: Sets the alert message to Enhanced

Event Messaging format. This is similar to the format available in iDRAC7.

For example, to set the message format to traditional use the following command: omconfig preferences messages format=traditional

Omconfig Preferences Useraccess

Depending on the policies of your organization, you may want to restrict the access that some user levels have to Server Administrator. The omconfig preferences useraccess command allows you to grant or withhold the right of users and power users to access Server Administrator.

The following table displays the valid parameters for the command:

Table 37. Enabling User Access For Administrators, Power Users, And Users

Command omconfig preferences useraccess enable=user omconfig preferences useraccess enable=poweruser omconfig preferences useraccess enable=admin

Result

Grants Server Administrator access to Users, Power Users, and Administrators.

Grants Server Administrator access to Power Users and

Administrators.

Grants Server Administrator access to Administrators only.

Description

Least restrictive form of user access.

Excludes user level access only.

Most restrictive form of user access.

Omconfig Preferences Webserver

Use the omconfig preferences webserver command to set the encryption levels of the Server

Administrator Web server, configure the URL launch point in the Server Administrator Web server environment, and to set the JRE version for the Server Administrator.

The following table displays the name=value pairs you can use with this command:

Table 38. Valid Parameters Of Omconfig Preferences Webserver name=value pair 1 attribute=sslencryption name=value pair 2 setting=autonegotiate |

128bitorhigher

Description autonegotiate: Sets the encryption levels automatically based on your Web browser settings.

128bitorhigher: Sets the encryption levels to 128-bit or higher.

attribute=seturl host=<string> port=<value> Enables you to configure the URL launch point in the Server

105

name=value pair 1 attribute=signalgorithm attribute=setjre name=value pair 2 algorithm=MD5 | SHA1 | SHA256

| SHA512

Description

Administrator Web server environment.

MD5: Sets the key signing algorithm to MD5.

SHA1: Sets the key signing algorithm to SHA1.

SHA256: Sets the key signing algorithm to SHA256.

SHA512: Sets the key signing algorithm to SHA512.

jreversion=bundled |value bundled: Sets the OMSA bundled version as default.

value: Sets the version which user inputs and available on the system.

For example, to set the URL launch point use the following command: omconfig preferences webserver attribute=seturl host=<name>, ip, fqdn> port=<number>

The host input must contain a valid IPv4 or IPv6 address, or a valid hostname.

To set the signing algorithm value, use the following command: omconfig preferences webserver attribute=signalgorithm algorithm=MD5

To set the JRE versions, use the following command: omconfig preferences webserver attribute=setjre jreversion=<bundled | value>

Omconfig System Or Omconfig Servermodule

Use the omconfig system or omconfig servermodule commands to clear logs, determine how various shutdown actions occur, set initial values or edit values for cost of ownership information, and determine how to respond to a hung operating system.

Omconfig System Alertaction Or Omconfig Servermodule Alertaction

You can use the omconfig system alertaction or omconfig servermodule alertaction command to determine how Server Administrator responds when a component has a warning or failure event.

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

106

Defining Alert Actions

An alert action is an action that you specify for the system to take when specified conditions are met.

Alert actions determine in advance what actions to take for warning or failure events on intrusion, fans, temperatures, voltages, power supplies, memory, and redundancy.

For example, if a fan probe on the system reads a fan RPM of 300 and your minimum warning threshold value for that fan probe is 600 RPM, then the system generates a fan probe warning. Alert action settings determine how users are notified of this event. You can also configure alert actions for temperature, voltage, and probe readings that fall within the warning or failure range.

Syntax For Setting Alert Actions

Setting an alert action requires two name=value pairs. The first name=value pair is the event type. The second name=value pair is the action to take for this event. For example, in the command: omconfig system alertaction event=powersupply broadcast=true or omconfig servermodule alertaction event=powersupply broadcast=true

The event is a power supply failure and the action is to broadcast a message to all Server Administrator users.

Available Alert Actions

The following table displays the alert actions for each component that allows you to configure an alert action:

Table 39. Valid Parameters of Alert Actions For Warning and Failure Events

Alert Action Setting alert=true | false

Description true: Enables the system's console alert. When enabled, the monitor attached to the system from which you are running Server Administrator displays a visual alert message.

false: Disables the system's console alert.

broadcast=true | false true: Enables a message or alert to broadcast to all users who have an active terminal (or Remote

Desktop) session (Windows) or to operators that have an active shell on the local system (Linux.) false: Disables alert broadcasts.

clearall=true execappath=<string>

Clears all actions for this event.

Sets the fully qualified path and file name of the application you want to execute in case of an event for the component described in this window.

107

Alert Action Setting Description

NOTE: On Linux systems, user or user groups upgraded to administrator or administrator groups cannot configure this alert action setting.

Disables the executable application.

execapp=false

Components And Events For Alert Actions

The following table provides the events for which you can set alert actions. Components are listed in alphabetical order, except that warning events always precede failure events for a component.

Table 40. Valid Parameters Of Events for Alert Actions

Event Name event=batterywarn event=batteryfail event=fanwarn

Description

Sets actions when a battery probe detects a warning value.

Sets actions when a battery probe detects a failure value.

Sets actions when a fan probe detects a warning value.

event=fanfail Sets actions when a fan probe detects a failure value.

event=hardwarelogwarn Sets actions when a hardware log detects a warning value.

event=hardwarelogfull event=intrusion

Sets actions when a hardware log is full.

Sets actions when a chassis intrusion event is detected.

event=memprefail event=memfail

Sets actions when a memory probe detects a prefailure value.

Sets actions when a memory probe detects a failure value.

event=systempeakpower Sets actions when a power consumption probe detects peak power value.

event=systempowerwarn Sets actions when a power consumption probe detects a warning value.

event=systempowerfail event=powersupply

Sets actions when a power consumption probe detects a failure value.

Sets actions when a power supply probe detects a failure value.

event=powersupplywarn Sets actions when a power supply probe detects a warning value.

event=processorwarn Sets actions when a processor probe detects a warning value.

event=processorfail event=redundegrad

Sets actions when a processor probe detects a failure value.

Sets actions when a redundant component becomes inoperative, resulting in less than full redundancy for that component.

event=redunlost event=tempwarn event=tempfail event=voltwarn

Sets actions when one or more redundant components become inoperative, resulting in a lost or a "no redundant components working" condition for that component.

Sets actions when a temperature probe detects a warning value.

Sets actions when a temperature probe detects a failure value.

Sets actions when a voltage probe detects a warning value.

108

Event Name event=voltfail

Description

Sets actions when a voltage probe detects a failure value.

event=watchdogasr event=removableflashme diapresent event=removableflashme diaremoved event=removableflashme diafail event=storagesyswarn event=storagesysfail event=storagectrlwarn event=storagectrlfail event=pdiskwarn event=pdiskfail

Sets actions that Server Administrator performs on the next system startup after a watchdog Automatic System Recovery (ASR) is performed for a hung operating system.

Sets actions that Server Administrator performs when the system detects a removable flash media.

Sets actions that Server Administrator performs when a removable flash media is removed.

Sets actions that Server Administrator performs when a removable flash media fails.

Sets actions when a storage system detects a warning value.

Sets actions when a storage system detects a failure value.

Sets actions when a storage controller detects a warning value.

Sets actions when a storage controller detects a failure value.

Sets actions when a physical disk detects a warning value.

Sets actions when a physical disk detects a failure value.

event=vdiskwarn event=vdiskfail

Sets actions when a virtual disk detects a warning value.

Sets actions when a virtual disk detects a failure value.

event=enclosurewarn Sets actions when an enclosure detects a warning value.

event=enclosurefail event=storagectrlbatteryw arn

Sets actions when an enclosure detects a failure value.

Sets actions when a storage controller battery detects a warning value.

NOTE: This event is not available on blade systems.

event=storagectrlbatteryf ail

Sets actions when a storage controller battery detects a failure value.

NOTE: This event is not available on blade systems.

Example Set Alert Action Commands

The following are examples of valid example commands. For each successful command issued, the following message is displayed:

Alert action(s) configured successfully.

Example Current Probe Actions

To disable system console alert if a current probe detects a warning event, type: omconfig system alertaction event=currentwarn alert=false or omconfig servermodule alertaction event=currentwarn alert=false

109

To enable broadcast messages if a current probe detects a failure event, type: omconfig system alertaction event=currentfail broadcast=true or omconfig servermodule alertaction event=currentfail broadcast=true

Example Fan Probe Actions

To generate alerts when a fan probe detects a failure value, type: omconfig system alertaction event=fanfail alert=true or omconfig servermodule alertaction event=fanfail alert=true

Example Chassis Intrusion Actions

To clear all alert actions for chassis intrusion, type: omconfig system alertaction event=intrusion clearall=true or omconfig servermodule alertaction event=intrusion clearall=true

Commands For Clearing Logs

You can use the omconfig system or omconfig servermodule command to clear the following logs: the alert log, command log, and hardware or ESM log.

To clear the contents of the alert log, type: omconfig system alertlog action=clear or omconfig servermodule alertlog action=clear

NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing the command log resolves this condition.

To clear the contents of the command log, type: omconfig system cmdlog action=clear or omconfig servermodule cmdlog action=clear

To clear the contents of the ESM log, type: omconfig system esmlog action=clear or omconfig servermodule esmlog action=clear

NOTE: For more information about alert messages, see the Dell OpenManage Server Administrator

Messages Reference Guide at dell.com/support/manuals.

110

Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations

Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP addresses for alert destinations.

The following table displays the valid parameters for the command.

NOTE: You can either specify the index and IP address as parameters together or you can set only the community string as a parameter.

NOTE: Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address. On 12G systems with iDRAC7 specific versions, the index can accept IPv4, IPv6, or FQDN.

Table 41. Valid Parameters Of Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations name=Value Pair Description destenable=true | false true: Enables an individual platform event filter destination after a valid IP address has been set.

false: Disables an individual platform event filter.

index=number Sets the index for the destination.

ipaddress=<ipv4 address

| ipv6 address | fqdn>

Sets the IP address for the destination.

NOTE: On 12G systems with iDRAC7 specific versions, ipaddress can also be a Fully Qualified Domain Name (FQDN).

communitystr=text Sets the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station.

Omconfig System Platformevents Or Omconfig Servermodule

Platformevents

Use the omconfig system platformevents or omconfig servermodule platformevents command to configure shutdown action, if any, taken for a specific platform event. You can also enable or disable platform event filter alert generation.

CAUTION: If you set a platform event shutdown action to anything other than none or power

reduction, the system is forcefully shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first shutting down the operating system or any of the applications running on your system.

The following table displays the valid parameters for the command.

NOTE: Alert settings are mutually exclusive and you can set one at a time only. The action settings are also mutually exclusive and you can set one at a time only. However, alert and action settings are not mutually exclusive of each other.

111

Table 42. Parameters For Alert Action Command

Action action=disable action=enable action=none

Description

Disables the SNMP alert.

Enables the SNMP alert.

Takes no action when the system is hung or has crashed.

action=powercycle Turns off the electrical power to the system, pauses, turns the power on, and reboots the system.

action=poweroff action=powerreduc tion

Turns off the electrical power to the system.

Reduces the processor speed until the power consumption comes down and reaches below the warning threshold. If the system power consumption stays below the warning threshold, increases the processor speed.

NOTE: This action is applicable only for PowerEdge Rack and Tower systems earlier than PowerEdge 11G systems.

action=reboot Forces the operating system to shut down and initiates system startup, performs

BIOS checks, and reloads the operating system.

Components And Events Of Platform Events

The following table lists the components and the events for which you can set platform events.

Components are listed in alphabetical order, except that warning events always precede failure events for a component.

Table 43. Valid Parameters Of Omconfig System Platformevents

Event Name alertsenable=true | false

Description true: Enables generation of platform event filter alerts.

false: Disables generation of platform event filter alerts.

NOTE: This setting is independent of the individual platform event filter alert settings. For a platform event filter to generate an alert, both the individual alert and the global event alert are enabled.

event=batterywarn event=batteryfail event=discretevolt event=fanfail event=hardwarelogfail event=intrusion

Sets action or enables or disables alert generation when a battery device detects that the battery is pending a failure condition.

Sets action or enables or disables alert generation when a battery device detects that the battery has failed.

Sets action or enables or disables alert generation when a discrete voltage probe detects that the voltage is too low for proper operation.

Sets action or enables or disables alert generation when a fan probe detects that the fan is running too slow or not at all.

Enables or disables alert generation when a hardware log detects a failure value.

Sets action or enables or disables alert generation when a chassis is opened.

112

Event Name event=powerwarn event=powerabsent event=powerfail event=processorwarn event=processorfail event=processorabsent

Description

Sets action or enables or disables alert generation when a power device probe detects that the power supply, voltage regulator module, or DC to DC converter is pending a failure condition.

Sets action or enables or disables alert generation when a processor probe detects that the power supply is absent.

Sets action or enables or disables alert generation when a power device probe detects that the power supply, voltage regulator module, or DC to DC converter has failed.

Sets action or enables or disables alert generation when a processor probe detects that the processor is running at less than peak performance or speed.

Sets action or enables or disables alert generation when a processor probe detects that the processor has failed.

Sets action or enables or disables alert generation when a processor probe detects that the processor is absent.

event=redundegrad event=redunlost

Sets action or enables or disables alert generation when the system fans and/or power supplies become inoperative, resulting in less than full redundancy for that component.

Sets action or enables or disables alert generation when the system fans and/or power supplies become inoperative, resulting in a lost or a

no redundant components working condition for that component.

event=systempowerwarn Sets actions when a power consumption probe detects a warning value.

Sets actions when a power consumption probe detects a failure value.

event=systempowerfail event=tempwarn Sets action or enables or disables alert generation when a temperature probe detects that the temperature is approaching the maximum high or low limits.

event=removableflashmediapre sent

Sets actions that Server Administrator performs when the system detects a removable flash media.

event=removableflashmediawa rn

Sets actions that Server Administrator performs when a removable flash media warning is displayed.

event=removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails.

event=tempfail Sets action or enables or disables alert generation when a temperature probe detects that the temperature is either too high or low for proper operation.

event=voltfail event=intdualsdcardcritical

Sets action or enables or disables alert generation when a voltage probe detects that the voltage is too low for proper operation.

Sets actions that Server Administrator performs when an internal dual

SD card critical event occurs.

113

Event Name event=intdualsdcardwarn

Description

Sets actions that Server Administrator performs when an internal dual

SD card warning is displayed.

event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual

SD card is not available.

event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual SD card is lost.

event=watchdogasr Enables or disables alert generation configured by the ASR when the system has hung or is not responding.

Omconfig System Events Or Omconfig Servermodule Events

Use the omconfig system events or omconfig servermodule events command to enable and disable

SNMP traps for the components on your system.

NOTE: Not all event types are present on the system.

There are four parameters in the name=value pair component of the omconfig system events command:

• Source

• Type

• Severity

• Index

Source

At present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event notification for the system’s components.

omconfig system events source=snmptraps or omconfig servermodule events source=snmptraps

Type

Type refers to the name of the component(s) involved in the event. The following table displays the valid parameters for system event types.

Table 44. System Event Type Parameters name=value pair type=accords type=battery type=all type=fanenclosures type=fans type=intrusion

Description

Configures events for AC power cords.

Configures events for battery.

Configures events for all device types.

Configures events for fan enclosures.

Configures events for fans.

Configures events for chassis intrusion.

114

name=value pair type=log type=memory type=powersupplies type=redundancy type=systempower type=temps type=volts

Description

Configures events for logs.

Configures events for memory.

Configures events for power supplies.

Configures events for redundancy.

Configures events for system power.

Configures events for temperatures.

Configures events for voltages.

type=systempeakpower Configures events for system peak power.

type=removableflashme dia

Configures events for removable flash media.

Severity

In the context of configuring events, severity determines how severe an event is, before Server

Administrator notifies you of the event for a component type. When there are multiple components of the same type in the same system chassis, you can specify whether you want notification for event severity according to the number of the component by using the index=<n> parameter. The following table displays the valid severity parameters.

Table 45. System Event Severity Parameters

Command Result Description

Enables notification for informational, warning, and critical events.

Least restrictive form of event notification.

omconfig system events type=<component name> severity=info or omconfig servermodule events type=<component name> severity=info omconfig system events type=<component name> severity=warning or omconfig servermodule events type=<component name> severity=warning omconfig system events type=<component name> severity=critical or omconfig servermodule events type=<component name> severity=critical omconfig system events type=<component name> severity=none or omconfig

Enables notification for warning and critical events.

Enables notification for critical events only.

Disables event notification.

Omits informational event notification, for example, when a component returns to normal status.

Restrictive form of event notification.

No event notification.

115

Command servermodule events type=<component name> severity=none

Result Description

Index

Index refers to the number of an event for a particular component. Index is an optional parameter. When you omit the index parameter, events are configured for all components of the specified type, such as all fans. For example, when a system contains more than one fan, you can enable or disable event notification for a particular fan. An example command is as follows: omconfig system events type=fan index=0 severity=critical or omconfig servermodule events type=fan index=0 severity=critical

As a result of the example command, Server Administrator sends an SNMP trap only when the first fan in the system chassis (index 0) has reached critical fan RPMs.

Omconfig System Webserver Or Omconfig Servermodule Webserver

Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the

Web server. The following table displays the valid parameters for the command.

Table 46. Valid Parameters Of Web Server Configuration name=value pair Description action=start Starts the Web server.

action=stop action=restart

Stops the Web server.

Restarts the Web server.

Omconfig System Recovery Or Omconfig Servermodule Recovery

Use the omconfig system recovery or omconfig servermodule recovery command to set the action when the operating system hangs or crashes. You can also set the number of seconds that must pass before the system is considered to have a hung operating system. The following table lists the valid parameters for the command

NOTE: The upper and lower limits for the timer are dependent on the system model and configuration.

Table 47. Valid Parameters Of Omconfig System Recovery Or Omconfig Servermodule Recovery name=value pair action=none action=reboot action=poweroff

Description

Takes no action when the operating system is hung or has crashed.

Shuts down the operating system and initiates system startup, performing BIOS checks, and reloading the operating system.

Turns off electrical power to the system.

116

name=value pair Description action=powercycle Turns off electrical power to the system, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to re-initialize system components such as hard drives.

timer=<n> Number of seconds that must pass before the system is considered to have a hung operating system (from 20 seconds to 480 seconds).

Example Recovery Commands

To set the action on hung operating system detection to powercycle, type: omconfig system recovery action=powercycle or omconfig servermodule recovery action=powercycle

To set the system to hang for 120 seconds, before a recovery action is initiated, type: omconfig system recovery timer=120 or omconfig servermodule recovery timer=120

Omconfig System Shutdown Or Omconfig Servermodule Shutdown

Use the omconfig system shutdown or omconfig servermodule shutdown command to determine the way in which the system shuts down. During system shutdown, the default is to shut down the operating system before powering off the system. Shutting down the operating system first closes down the file system before powering the system down. If you do not want to shut down the operating system first, use the osfirst=false parameter. The following table displays the valid parameters for the command.

NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.

Table 48. Valid Parameters Of System Shutdown name=value pair Description action=reboot Shuts down the operating system and initiates system startup, performing BIOS checks and reloading the operating system.

action=poweroff Turns off the electrical power to the system.

action=powercycl e

Turns off the electrical power to the system, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to re-initialize system components such as hard drives.

osfirst=true | false true: Closes the file system and exits the operating system before shutting down the system.

false: Does not close the file system or shut down the operating system before shutting down the system.

117

Example Shutdown Commands

To set the shutdown action to reboot, type: omconfig system shutdown action=reboot or omconfig servermodule shutdown action=reboot

To bypass operating system shutdown before the system is powered off, type: omconfig system shutdown action=reboot osfirst=false or omconfig servermodule shutdown action=reboot osfirst=false

Omconfig System Thrmshutdown Or Omconfig Servermodule

Thrmshutdown

Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure a thermal shutdown action. You can configure the system for a thermal shutdown when a temperature probe detects a temperature probe warning or failure event.

The following table displays the valid parameters for the command:

Table 49. Valid Parameters Of Thermal Shutdown name=value pair severity=disabled | warning | failure

Description disabled: Disable thermal shutdown. An administrator must intervene.

warning: Perform a shutdown when a temperature warning event is detected. A warning event occurs when any temperature probe inside a chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature warning threshold value.

failure: Perform a shutdown when a temperature failure event is detected. A failure event occurs when any temperature probe inside a chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature failure threshold value.

Example Thermal Shutdown Commands

To trigger a thermal shutdown when a temperature probe detects a failure event, type: omconfig system thrmshutdown severity=failure or omconfig servermodule thrmshutdown severity=failure

To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown, type: omconfig system thrmshutdown severity=disabled or omconfig servermodule thrmshutdown severity=disabled

118

5

Omconfig System Or Servermodule

Assetinfo: Editing Cost Of Ownership

Values

The omconfig system assetinfo or omconfig servermodule assetinfo command helps you to edit a comprehensive set of parameters that make up the total cost of ownership of the system. This section explains the parameters that are reported and configured under the omconfig system assetinfo or omconfig servermodule assetinfo command.

Using the omconfig system assetinfo or omconfig servermodule assetinfo command, you can set governing values for configurable objects. Examples of assetinfo configuration capabilities include setting values for system owner, purchase price, details of any lease that is in effect, depreciation methods and rates, and location of the system, warranty and extended warranty duration, outsourcing details, and service level agreement.

NOTE: Power Users and Administrators can add and edit asset information.

The following table lists the systems on which omconfig commands are applicable:

Table 50. System Availability for the omconfig Command

Command Level 1 omconfig

Command Level 2 servermodule mainsystem system chassis

Applicable to

Blade systems

Blade systems

Rack and Tower systems

Rack and Tower systems

Adding Acquisition Information

Acquisition refers to the facts about a business entity's purchase or lease of a system. Use the omconfig system assetinfo info=acquisition or omconfig servermodule assetinfo info=acquisition command to add detailed information about the purchase or lease of a system. The following table displays the valid parameters for the command:

119

Table 51. Valid Parameters Of omconfig system assetinfo info=acquisition or omconfig servermodule assetinfo info=acquisition

Command

Level 1 omconfig

Command

Level 2 system or servermodule

Command

Level 3 assetinfo

Name= Value

Pair 1 info=acquisiti on

Name= Value Pair 2 costcenter=<text> expensed=yes | no installdate=<mmddyy

> ponum=<n> purchasecost=<n> purchasedate=<mmd

dyy> signauth=<text> waybill=<n>

Description

The name or code for the business entity that acquired the system.

Whether the system is charged to a specific purpose or department such as research and development or sales.

Date the system was put to service.

Number of the document that authorized payment for the system.

Price the owner paid for the system.

Date the owner purchased the system.

Name of the person who approved the purchase or the service call on the system.

Receipt from the carrier for the goods received.

120

Example Command For Adding Acquisition Information

To provide a value for an acquisition parameter, type a command of the form: omconfig system assetinfo info=acquisition <name=value pair 2> or omconfig servermodule assetinfo info=acquisition

<name=value pair 2>. For example, type: omconfig system assetinfo info=acquisition purchasedate=122101 or omconfig servermodule assetinfo info=acquisition purchasedate=122101

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all of the parameters for name=value pair 2 belong to the same name=value pair 1. For example, to type more than one parameter value for info=acquisition, use the following example as a syntax guide: omconfig system assetinfo info=acquisition purchasecost=5000 waybill=123456 installdate=120501 purchasedate=050601 ponum=9999 signauth="John

Smith" expensed=yes costcenter=finance or omconfig servermodule assetinfo info=acquisition purchasecost=5000 waybill=123456 installdate=120501 purchasedate=050601 ponum=9999 signauth="John

Smith" expensed=yes costcenter=finance

The following message is displayed:

Asset information set successfully.

Adding Depreciation Information

Depreciation is a set of methods for computing the devaluation of the asset over time. For example, the depreciation of a system that is expected to have a useful life of 5 years is 20 percent. Use the omconfig system assetinfo info=depreciation or omconfig servermodule assetinfo info=depreciation command to add details about how the system's depreciation is computed. The following table shows the valid parameters for the command.

Table 52. Valid Parameters Of omconfig system assetinfo info=depreciation or omconfig servermodule assetinfo info=depreciation

Command

Level 1 omconfig

Command

Level 2 system or servermodule

Command

Level 3 assetinfo

Name= Value

Pair 1 info=depreciati on

Name= Value

Pair 2 duration=<n>

Description

Number of years or months over which a system is depreciated.

method=<text> Steps and assumptions used to compute the

121

Command

Level 1

Command

Level 2

Command

Level 3

Name= Value

Pair 1

Name= Value

Pair 2

Description percent=<n> unit=months | years system's depreciation.

Portion of 100 that an asset is devalued or depreciated.

Unit is months or years.

Example Command For Adding Depreciation Information

To provide a value for a depreciation parameter, type a command of the form: omconfig system assetinfo info=depreciation <name=value pair 2> or omconfig servermodule assetinfo info=depreciation

<name=value pair 2>. For example, type: omconfig system assetinfo info=depreciation method=straightline or omconfig servermodule assetinfo info=depreciation method=straightline

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Commands For Adding Acquisition Information

.

Adding Extended Warranty Information

Use the omconfig system extwarranty or omconfig servermodule extwarranty command to assign values for extended warranty information. A warranty is a contract between the manufacturer or dealer and the purchaser of a system. The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage. The extended warranty comes into force after the original warranty expires. For details on how to edit warranty values, see

Adding Warranty Information

.

The following table displays the valid parameters for the command

Table 53. Valid Parameters Of omconfig system assetinfo info=extwarranty Or omconfig servermodule assetinfo info=extwarranty

Command

Level 1 omconfig

Command

Level 2 system or servermodule

Command

Level 3

Name= Value

Pair 1 assetinfo info=extwarran ty

Name= Value Pair 2 Description cost=<cost> Cost of the extended warranty service.

enddate=<enddate> Date the extended warranty agreement ends.

122

Command

Level 1

Command

Level 2

Command

Level 3

Name= Value

Pair 1

Name= Value Pair 2 Description provider=<provider

> startdate=<startdate

>

Business entity that provides the extended warranty service.

Date the extended warranty service begins.

Example Command For Adding Extended Warranty Information

To provide a value for an extended warranty parameter, type a command of the form: omconfig system assetinfo info=extwarranty <name=value pair 2> or omconfig servermodule assetinfo info=extwarranty

<name=value pair 2>. For example, type: omconfig system assetinfo info=extwarranty enddate=012503 or omconfig servermodule assetinfo info=extwarranty enddate=012503

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Command For Adding Acquisition Information

.

Adding Lease Information

A lease is an agreement to pay for the use of a system for a specified period of time. The lessor retains ownership of the system. The following table displays the valid parameters for the command.

Table 54. Valid Parameters Of omconfig system assetinfo info=lease Or omconfig servermodule assetinfo info=lease

Command

Level 1 omconfig

Command

Level 2 system or servermodule

Command

Level 3 assetinfo

Name=

Value

Pair 1 info=leas e

Name= Value Pair 2 Description buyout=<amount> Amount of money paid to purchase a system from a lessor.

lessor=<lessor> Business entity that is leasing the system out.

multischedule=true

| false

Whether cost of leasing the system is computed by more than one rate schedule.

123

Command

Level 1

Command

Level 2

Command

Level 3

Name=

Value

Pair 1

Name= Value Pair 2 Description ratefactor=<factor> Factor used to calculate the lease payment.

value=<residual> Fair market value of the system at the end of the lease period.

Example Command For Adding Lease Information

To provide a value for a lease parameter, type a command of the form: omconfig system assetinfo info=lease <name=value pair 2> or omconfig servermodule assetinfo info=lease <name=value pair 2>.

For example, type: omconfig system assetinfo info=lease value=4500 or omconfig servermodule assetinfo info=lease value=4500

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfocommand at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1.

For an example, see Example Command For Adding Acquisition Information .

Adding Maintenance Information

Maintenance refers to activities required to keep the system in good working order. The following table displays the valid parameters for adding maintenance information.

Table 55. Valid Parameters Of omconfig system assetinfo info=maintenance Or omconfig servermodule assetinfo info=maintenance

Description Command

Level 1 omconfig

Command

Level 2 system or servermodule

Command

Level 3 assetinfo

Name= Value

Pair 1

Name= Value Pair

2 info=mainten ance enddate=<enddate

> provider=<provider

> startdate=<startdat

e>

Date the extended warranty agreement ends.

Business entity providing the maintenance service.

Date the maintenance begins.

124

Command

Level 1

Command

Level 2

Command

Level 3

Name= Value

Pair 1

Name= Value Pair

2 restrictions=<string

>

Description

Activities not covered by the maintenance contract.

Example Command For Adding Maintenance Information

To provide a value for a maintenance parameter, type a command of the form: omconfig system assetinfo info=maintenance <name=value pair 2> or omconfig system assetinfo info=maintenance

<name=value pair 2>.

For example, type: omconfig system assetinfo info=maintenance startdate=012504 or omconfig servermodule assetinfo info=maintenance startdate=012504

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Commands For Adding Acquisition Information

.

Adding Outsource Information

Outsourcing is the practice of contracting with another business to maintain the system in good working order. The following table displays the valid parameters for adding outsource information.

Table 56. Valid Parameters Of omconfig system assetinfo info=outsource Or omconfig servermodule assetinfo info=outsource

Description Comman d Level 1

Command

Level 2 omconfig system or servermodul e

Command

Level 3

Name=

Value Pair 1 assetinfo info=outsour ce

Name= Value Pair 2 levels=<n> problemcomponent=<comp

onent> providerfee=<providerfee> servicefee=<servicefee>

Levels of service that the provider offers.

System component that requires maintenance.

Amount of money charged for maintenance.

Amount of money charged for service.

125

Comman d Level 1

Command

Level 2

Command

Level 3

Name=

Value Pair 1

Name= Value Pair 2 signauth=<name>

Description

Person who signed or authorized the service.

Example Command For Adding Outsource Information

To provide a value for an outsource parameter, type a command of the form: omconfig system assetinfo info=outsource <name=value pair 2> or omconfig servermodule assetinfo info=outsource <name=value pair 2>. For example, type: omconfig system assetinfo info=outsource providerfee=75 or omconfig servermodule assetinfo info=outsource providerfee=75

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1.

For an example, see Example Command For Adding Acquisition Information .

Adding Owner Information

The owner is the party that holds legal property title to the system. The following table displays the valid parameters for adding owner information.

Table 57. Valid Parameters Of omconfig system assetinfo info=owner Or omconfig servermodule assetinfo info=owner

Name= Value Pair 2 Description Comman d Level 1

Command

Level 2

Comman d Level 3

Name=

Value Pair

1 omconfig system or servermodul e assetinfo info=owne r insuranceco=<company> ownername=<business> type=owned | leased | rented

Name of the insurance company that insures the system.

Business entity that owns the system.

Whether the user of the system owns, leases, or rents the system.

126

Example Command For Adding Owner Information

To provide a value for an owner parameter, type a command of the form omconfig system assetinfo info=owner <name=value pair 2> or omconfig servermodule assetinfo info=owner <name=value pair 2>.

For example, type: omconfig system assetinfo info=owner type=rented or omconfig servermodule assetinfo info=owner type=rented

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Command For Adding Acquisition Information

.

Adding Service Contract Information

A service contract is an agreement that specifies fees for preventive maintenance and repair of the system. The following table displays the valid parameters for adding contract information.

Table 58. Valid Parameters Of omconfig system assetinfo info=service Or omconfig servermodule assetinfo info=service

Comman d Level 1

Command

Level 2 omconfig system or servermodul e

Comman d Level 3

Name=

Value Pair 1

Name= Value Pair

2 assetinfo info=service renewed=true | false

Description

Whether the service agreement has been renewed.

type=<string> vendor=<business

>

Type of service that the contract covers.

Business entity that offers service on the system.

Example Command For Adding Service Information

To provide a value for a service parameter, type a command of the form omconfig system assetinfo info=service <name=value pair 2> or omconfig system assetinfo info=service <name=value pair 2>. For example, type: omconfig system assetinfo info=service vendor=fixsystemco or omconfig servermodule assetinfo info=service vendor=fixsystemco

The following message is displayed:

Asset information set successfully.

127

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Command For Adding Acquisition Information

.

Adding Support Information

Support refers to technical assistance that the system user can seek when the user seeks guidance on the proper use of a system to perform tasks. The following table displays the valid parameters for adding support information.

Table 59. Valid Parameters Of omconfig system assetinfo info=support Or omconfig servermodule assetinfo info=support

Description Comman d Level 1

Command

Level 2 omconfig system or servermodu le

Command

Level 3 assetinfo

Name=

Value Pair 1

Name= Value Pair 2 info=support automaticfix=<programna me> helpdesk=<text> outsourced=true | false type=network | storage

Name of any application used to fix a problem automatically.

The help desk name or contact information such as a phone number, email address, or website address.

Whether an external business entity provides technical support or the system owner's employees provide technical support.

Whether support is for network attached devices or for storage devices.

.

Example Command For Adding Support Information

To provide a value for a support parameter, type a command of the form omconfig system assetinfo info=support <name=value pair 2> or omconfig servermodule assetinfo info=support <name=value pair

2>. For example, type: omconfig system assetinfo info=support outsourced=true or omconfig servermodule assetinfo info=support outsourced=true

128

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Command For Adding Acquisition Information

.

Adding System Information

System information includes the primary user of the system, the phone number for the primary user, and the location of the system. The following table displays the valid parameters for adding system information.

Table 60. Valid Parameters Of omconfig system assetinfo info=system Or omconfig servermodule assetinfo info=system

Comman d Level 1

Command

Level 2 omconfig system or servermodu le

Comman d Level 3

Name=

Value Pair

1 assetinfo info=syste m

Name= Value Pair 2 location=<text>

Description

Location of the system.

primaryphone=<n> primaryuser=<user>

Phone number of the primary user of the system.

Primary user of the system.

Example Command For Adding System Information

To provide a value for a system parameter, type a command of the form omconfig system assetinfo info=system <name=value pair 2> or omconfig servermodule assetinfo info=system <name=value pair

2>. For example, type: omconfig system assetinfo info=system location=firstfloor or omconfig servermodule assetinfo info=system location=firstfloor

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Command For Adding Acquisition Information

.

Adding Warranty Information

Use the omconfig system warranty or omconfig servermodule warranty command to assign values for warranty information. A warranty is a contract between the manufacturer or dealer and the purchaser of a system. The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage. For details on editing extended warranty values, see

Adding Extended

Warranty Information . The following table displays the valid parameters for adding warranty information.

129

Table 61. Valid Parameters Of omconfig system assetinfo info=warranty Or omconfig servermodule assetinfo info=warranty

Description Command

Level 1

Command

Level 2 omconfig system or servermodul e

Command

Level 3 assetinfo

Name=

Value Pair 1 info=warrant y

Name= Value Pair 2 cost=<cost> Cost of the warranty service.

duration=<duration> enddate=<enddate> unit=days | months

Number of days or months that the warranty is in force.

Date the warranty agreement ends.

Whether the number for duration refers to days or months.

Example Command For Adding Warranty Information

To provide a value for a warranty parameter, type a command of the form omconfig system assetinfo info=warranty <name=value pair 2> or omconfig servermodule assetinfo info=warranty <name=value pair 2>. For example, type: omconfig system assetinfo info=warranty unit=days or omconfig servermodule assetinfo info=warranty unit=days

The following message is displayed:

Asset information set successfully.

You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see

Example Command For Adding Acquisition Information

.

130

Using The Storage Management Service

6

The CLI of Storage Management enables you to perform reporting, configuration, and management functions of Storage Management from an operating system command shell. The Storage Management

CLI also enables you to script command sequences.

The Storage Management CLI provides expanded options for the Dell OpenManage Server Administrator omreport and omconfig commands.

NOTE: For more information, see the Dell OpenManage Server Administrator Installation Guide and

Dell OpenManage Management Station Software Installation Guide. For more information on

Storage Management, see the Storage Management online Help or the Dell OpenManage Server

Administrator Storage Management User’s Guide .

CLI Command Syntax

Like all Server Administrator commands, the omreport and omconfig command syntax consists of specifying command levels. The first command level is the command name: omreport or omconfig.

Subsequent command levels provide a greater degree of specification regarding the type of object on which the command operates or the information that the command displays.

For example, the following omconfig command syntax has three levels: omconfig storage pdisk

The following table describes these command levels.

Table 62. Example Command Levels

Command level 1 omconfig

Command level 2 Command level 3 storage pdisk

Use

Specifies the command

Indicates the Server

Administrator service (in this case, Storage

Management) that implements the command

Specifies the type of object on which the command operates

131

Following the command levels, the omreport and omconfig command syntax may require one or more name=value pairs. The name=value pairs specify exact objects (such as a specific physical disk) or options

(such as blink or unblink) that the command implements.

For example, the following omconfig command syntax for blinking a physical disk has three levels and three name=value pairs: omconfig storage pdisk action=blink controller=id pdisk=<PDISKID> where PDISKID=<onnector:enclosureID:targetID | connector:targetID>

In this example, the id in controller=idis the controller number such that controller 1 is specified as controller=1.

Syntax Of Command Elements

The omreport and omconfig commands have multiple name=value pairs. These name=value pairs may include required, optional, and variable parameters. The following table describes the syntax used to indicate these parameters.

Table 63. Syntax For Name=Value Pairs

Syntax controller=id

Description

Indicates the controller ID as reported by the omreport storage controller command. To obtain these values, type omreport storage controller to display the controller

IDs and then type omreport storage pdisk controller=id to display the IDs for the physical disks attached to the controller.

For example, the controller=id parameter is specified as controller=1.

connector=id

Indicates the connector ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage connector controller=id to display the IDs for the connectors attached to the controller.

For example, the connector=id parameter is specified as connector=2.

vdisk=id enclosure=<ENCLOSUREID>

Indicates the virtual disk ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=id to display the

IDs for the virtual disks on the controller.

For example, the vdisk=id parameter is specified as vdisk=3.

Indicates a particular enclosure by specifying either enclosure=connector or enclosure=connector:enclosureID.

To obtain these values, type omreport storage controller to display the controller IDs and then type

132

|

Syntax pdisk=<PDISKID> battery=id

< >

[ ]

Description omreport storage enclosure controller=id to display the IDs for the enclosures attached to the controller.

Indicates a particular physical disk by specifying either connector:targetID or connector:enclosureID:targetID.

To obtain the values for the connector, enclosure, and physical disk (targetID), type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=id to display the

IDs for the physical disks attached to the controller.

Indicates the battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=id to display the ID for the controller battery.

The caret symbols (< >) enclose variable elements that you must specify.

For example, the name=<string>parameter is specified as name=VirtualDisk1.

The bracket symbols ([ ]) indicate optional elements that you can choose whether or not to specify.

For example, when creating a virtual disk, the [name=<string>] parameter indicates that you have the option of specifying the virtual disk name. If you omit this parameter from the syntax, then a default name for the virtual disk is chosen for you.

The pipe symbol (|) separates two or more options from which only one is selected.

For example, when creating a virtual disk, the cachepolicy=d | c indicates that the cache policy is specified as either cachepolicy=d or cachepolicy=c.

User Privileges For Omreport Storage And Omconfig

Storage

Storage Management requires Administrator privileges to use the omconfig storage command. User and

Power User privileges are sufficient to use the omreport storage command.

133

7

Omreport Storage Commands

The omreport command allows you to view storage component information for disks, controllers, enclosures, batteries, global storage properties, connectors and cachecades that are part of the storage system. The omreport command helps to get reports with the level of detail that you want.

The commands may vary in, whether they define the fields that appear in the results of a particular omreport command. Fields are defined only if they have a special or less familiar use.

The following sections provide the omreport command syntax required to display the information of various storage components.

To see a list of valid commands for omreport storage, type: omreport storage -?

The following table provides the omreport storage command syntax.

Table 64. Omreport Storage Help

Command

Level 1 omreport

Command

Level 2 storage

Command

Level 3

Use pdisk vdisk controller enclosure battery globalinfo connector cachecade

Displays a list of storage components for which omreport commands are available.

Displays a list of the omreport storage pdisk parameters for displaying physical disk information.

Displays a list of omreport storage vdisk parameters for displaying virtual disk information.

Displays a list of the omreport storage controller parameters for displaying controller information.

Displays a list of the omreport storage enclosure parameters for displaying enclosure information.

Displays a list of the omreport storage battery parameters for displaying battery information.

Displays a list of the omreport storage globalinfo parameters for displaying global storage property information.

Displays a list of the omreport storage connector parameters for displaying connector information.

Displays a list of the omreport storage cachecade parameters for displaying cachecade properties.

134

Command

Level 1

Command

Level 2

Command

Level 3 pciessed

Use

Displays the properties of the PCIe SSD subsystem.

fluidcache Displays the fluid cache properties and the associated fluid cache disks.

fluidcachepool Displays fluid cache pool properties.

partition Displays the partition details of the specified virtual disk.

fluidcachedisk Displays the fluid cache disk properties.

Omreport Physical Disk Status

The following table describes the syntax for the omreport Physical Disk commands.

Table 65. Omreport Physical Disk Commands

Required Command Levels (1, 2,

3) And name=value pair

Optional name=value pairs Use omreport storage pdisk controller=id, where id is the controller number. For example, controller=0

Displays all physical disks attached to the specified controller.

NOTE: If a physical disk was replaced by another disk as part of the replace member operation, the state of the physical disk is displayed as

Replacing.

vdisk=id, where id is the virtual disk number. For example, vdisk=1

Displays all physical disks included in the specified virtual disk on the controller.

cachecade=id where id is the cachecade number. For example, cachecade=1

Displays all physical disks included in the specified cachecade on the controller.

connector=id where id is the connector number. For example, connector=1

Displays all physical disks attached to the specified connector on the controller.

pdisk=connectorID : targetID | connectorID : enclosureID : slotID, where

connectorID:targetID is the connector number and the physical disk number and

connectorID:enclosureID:slotID

is the connector number,

Displays the specified physical disk on the specified connector on the controller.

135

Required Command Levels (1, 2,

3) And name=value pair

Optional name=value pairs enclosure number, and slot number. For example, pdisk=0:2 or pdisk=0:1:2

Use

omreport Virtual Disk Status

The following table describes the syntax for the omreport Virtual Disk commands:

Table 66. omreport Virtual Disk Commands

Required Command Levels (1, 2,

3) omreport storage vdisk

Optional name=value pairs Use controller=id, where id is the controller number. For example, controller=0.

controller=id vdisk=id, where id is the controller number and the virtual disk number. For example, controller=0 vdisk=1.

Displays property information for all virtual disks on all controllers.

Displays all virtual disks on the specified controller.

Displays the specified virtual disk on the controller.

Omreport Controller Status

The following table describes the syntax for the omreport Controller commands

Table 67. Omreport Controller Commands

Required Command

Levels (1, 2, 3)

Optional name=value pairs Use omreport storage controller

Displays property information for all controllers attached to the system.

controller=id, where id is the controller number. For example, controller=0 controller=id info=foreignkeyids controller=id info=pdslotreport

Displays the specified controller and all attached components such as enclosures, virtual disks, physical disks, and so on.

Displays the locked foreign configuration information for import or clear operations.

Displays the empty and occupied slot details of enclosures in the controller.

NOTE: This command is not supported on

Blackplane, SCSI, and SWRAID controllers.

136

Omreport Enclosure Status

The following sections provide the omreport storage enclosure command syntax required to execute the enclosure commands. The following table describes the syntax for the omreport Enclosure commands.

Table 68. Omreport Enclosure Commands

Required Command

Levels (1, 2, 3)

Optional name=value pairs Use omreport storage enclosure

Displays property information for all enclosures attached to the system.

controller=id, where id is the controller number

Displays all enclosures connected to the controller.

controller=id enclosure=<ENCLOSUREID>, where id is the controller number and

<ENCLOSUREID>is the enclosure ID.

Example for SCSI controllers: controller=0 enclosure=2. Example for

SAS controllers: controller=0 enclosure=1:2.

Displays the specified enclosure and its components.

Omreport Temperature Probe Status

The following table describes the syntax for the omreport Probe commands

Table 69. Omreport Temperature Probe Commands

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs Use omreport storage enclosure Displays property information for all enclosures attached to the system.

controller=id enclosure=<ENCLOSUREID> info=temps where id is the controller number and

<ENCLOSUREID> is the enclosure

ID. Example for SCSI controllers: controller=0 enclosure=2 info=temps. Example for SAS controllers: controller=0 enclosure=1:2 info=temps

Displays the temperature probes for the specified enclosure.

controller=id enclosure=<ENCLOSUREID> info=temps index=n where id is the controller number and

<ENCLOSUREID> is the enclosure

Displays the temperature probes for the specified enclosure.

137

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs number and n is the number of a temperature probe. For example: controller=0 enclosure=2 info=temps index=1

Use

Omreport Fan Status

The following table describes the syntax for the omreport Fan commands

Table 70. Omreport Fan Status

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs omreport storage enclosure

Use

Displays property information for all enclosures attached to the system.

controller=id enclosure=<ENCLOSUREID> info=fans where id is the controller number and

ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2

NOTE: For SCSI controllers, the ID specified in enclosure=<ENCLOSUREID> is the connector number and for Serial Attached SCSI (SAS) controllers, ID is the connectorNumber:Enclosur eIndex.

Displays the fans for the specified enclosure.

controller=id enclosure=<ENCLOSUREID> info=fans index=n where id is the controller number and

ENCLOSUREID is the enclosure number and n is the number of a fan. For example: controller=0 enclosure=2 info=fans index=1

Displays the specified fan.

Omreport Power Supply Status

The following table describes the syntax for the omreport Power Supply commands

138

Table 71. Omreport Power Supply Commands

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs omreport storage enclosure

Use controller=id enclosure=<ENCLOSUREID> info=pwrsupplies where id is the controller number and

ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2 controller=id enclosure=<ENCLOSUREID> info=pwrsupplies index=n where id is the controller number and

ENCLOSUREID is the enclosure number and n is the number of a power supply. For example: controller=0 enclosure=2 info=pwrsupplies index=1

Displays property information for all enclosures attached to the system.

Displays the power supplies for the specified enclosure.

Displays the specified power supply.

Omreport EMM Status

The following table describes the syntax for the omreport EMM commands

NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.

Table 72. Omreport EMM Commands

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs omreport storage enclosure

Use

Displays property information for all enclosures attached to the system.

Displays the enclosure management modules (EMMs) for the specified enclosure.

controller=id enclosure=<ENCLOSUREID> info=emms where id is the controller number and

ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2 controller=id enclosure=<ENCLOSUREID> info=emms index=n where id is the controller number and

Displays the specified EMMs.

139

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs

ENCLOSUREID is the enclosure number and n is the number of an EMM. For example: controller=0 enclosure=2 info=emms index=1

Use

Omreport Enclosure Slot Occupancy Report

The following table describes the syntax for the omreport Enclosure Slot Occupancy Report commands

Table 73. Omreport Enclosure Slot Occupancy Report Commands

Required Command Levels (1, 2,

3) and name=value pair

Optional name=value pairs Use omreport storage enclosure Displays property information for all enclosures attached to the system.

controller=id enclosure=<ENCLOSUREID> info=pdslotreport, where id is the controller number and

ENCLOSUREID is the enclosure number. For example: controller=0 enclosure=2

Displays the empty and occupied slot details for the specified enclosure.

NOTE: This command is not supported on Blackplane,

SCSI, and SWRAID controllers.

Omreport Battery Status

The following table describes the syntax for the omreport Battery commands

Table 74. Omreport Battery Commands

Required Command Levels (1, 2,

3)

Optional name=value pairs Use omreport storage battery Displays all batteries present on all controllers on the system

(Some controllers do not have batteries).

Displays the battery on the specified controller.

controller=id, where id is the controller number. For example: controller=0 controller=id battery=id, where id is the controller number. For example: controller=0

Displays the specified battery.

Omreport Global Information

The following table describes the syntax for the omreport Global Information commands.

140

Table 75. Omreport Global Information Commands

Required Command Levels (1,

2, 3) omreport storage globalinfo

Optional name=value pairs Use

Displays whether smart thermal shutdown is enabled or disabled.

For more information, see

Omconfig Global Enable Smart

Thermal Shutdown

.

Displays the hot spare protection policy that you have set. For more information on setting hot spare protection policy, see the Dell

OpenManage Server Administrator

Storage Management User’s Guide

at dell.com/support/manuals.

Omreport Connector Status

The following table describes the syntax for the omreport Connector commands

Table 76. Omreport Connector Commands

Required Command Levels (1, 2,

3) omreport storage connector

Optional name=value pairs Use

Displays all connectors present on all controllers on the system.

NOTE: This command works only when the controller ID is specified.

controller=id, where id is the controller number. For example: controller=0

Displays the connectors on the specified controller.

controller=id connector=id, where id is the connector number. For example, connector=0

Displays the specified connector.

NOTE: When the connectors are connected to the enclosure in redundant path mode, the Name of the connector is displayed as

Logical Connector.

Omreport Cachecade Status

The following table describes the syntax for the omreport Cachecade commands

141

Table 77. Omreport Cachecade Commands

Required Command Levels

(1, 2, 3)

Optional name=value pairs omreport storage cachecade controller=id, where id is the controller number. For example, controller=0.

controller=id cachecade=id, where id is the controller number and the cachecade number. For example, controller=0 cachecade=1.

Use

Displays property information for all cachecades on all controllers.

Displays all cachecades on the specified controller.

Displays the specified cachecade on the controller.

Omreport PCIe SSD Status

The following table describes the syntax for the omreport pciessd commands.

Table 78. omreport PCIe SSD Command

Use Required Command Levels (1, 2,

3) And name=value pair omreport storage pciessd

Optional name=value pairs

Displays the properties of the

PCIe SSD subsystem.

subsystem=id Displays the properties of the specified PCIe subsystem.

Omreport Fluid Cache Status

The following table describes the syntax for the omreport fluidcache commands.

Table 79. omreport Fluid Cache Command

Use Required Command Levels (1, 2, 3) And name=value pair omreport storage fluidcache

Displays fluid cache properties and the associated fluid cache disks.

Omreport Fluid Cache Pool Status

The following table describes the syntax for the omreport fluidcachepool commands.

Table 80. omreport Fluid Cache Pool Command

Use Required Command Levels (1, 2, 3) And name=value pair omreport storage fluidcachepool

Displays the properties of the fluid cache pool.

142

omreport Partition Status

The following table describes the syntax for the omreport partition commands.

Table 81. omreport Partition Command

Use Required Command Levels (1, 2,

3) And name=value pair omreport storage partition

Optional name=value pairs

Displays the partition details of the specified virtual disk.

controller=id vdisk=id, where id is the controller number and the virtual disk number. For example: controller=0 vdisk=1.

Displays all the partitions in the specified virtual disk on the controller.

Omreport Fluid Cache Disk Status

The following table describes the syntax for the omreport fluidcachedisk commands.

Table 82. omreport Fluid Cache Disk Command

Use Required Command Levels (1, 2, 3) And name=value pair omreport storage fluidcachedisk

Displays the properties of the fluid cache disks.

Omreport Storage Tape

The following table describes the syntax for the omreport storage tape command.

Table 83. Omreport Storage Tape Commands

Use Required Command Levels

(1, 2, 3)

Optional name=value pairs omreport storage tape controller=id, where id is the controller number. For example: controller=0.

connector=id

Display tape drive properties.

Displays all tape drives.

tape=<tape id>, where tapeid=id=<connector:targetID>

Displays all the tape drives on the specified connector.

Displays the specified tape drive.

143

8

Omconfig Storage Commands

The omconfig commands allows you to configure physical disks, virtual disks, controllers, enclosures, batteries, global information, connectors, and cachecades.

To see a list of valid commands for omconfig storage, type: omconfig storage -?

The following table provides the omconfig storage command syntax:

Table 84. Omconfig Storage Help

Command

Level 1 omconfig

Command

Level 2

Command

Level 3

Use storage pdisk vdisk controller enclosure battery globalinfo connector

Sets the storage component properties for which omconfig commands are available.

Displays the list of omconfig storage pdisk parameters for configuring physical disks.

Displays the list of omconfig storage vdisk parameters for configuring virtual disks.

Displays a list of the omconfig storage controller parameters for configuring controllers.

Displays a list of the omconfig storage controller parameters for configuring enclosures.

Displays a list of the omconfig storage battery parameters for configuring batteries.

Displays a list of the omconfig storage globalinfo parameters for configuring global storage properties.

Displays a list of the omreport storage connector parameters for configuring connectors.

cachecade fluidcache

Displays a list of the omconfig storage cachecade parameters for configuring cachecades.

Displays the fluid cache properties and the associated fluid cache disks.

fluidcachepool Displays the fluid cache pool properties.

partition Displays the partition details of the specified controller and virtual disk.

144

Command

Level 1

Command

Level 2

Command

Level 3

Use fluidcachedisk Displays the fluid cache disk properties.

Omconfig Physical Disk Commands

The following sections provide the omconfig command syntax required to execute physical disk tasks

Table 85. Omconfig Physical Disk Commands

Optional name=value pairs Required Command Levels (1,

2, 3) omconfig storage pdisk action=blink controller=id pdisk=<PDISKID> action=unblink controller=id pdisk=<PDISKID> action=remove controller=id pdisk=<PDISKID> action=instantsecureerase controller=id pdisk=<PDISKID> action=cryptographicerase controller=id pdisk=<PDISKID> action=initialize controller=id pdisk=<PDISKID> action=offline controller=id pdisk=<PDISKID> action=online controller=id pdisk=<PDISKID> action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=<yes | no> action=rebuild controller=id pdisk=<PDISKID> action=cancelrebuild controller=id pdisk=<PDISKID> action=cancelreplacemember controller=id pdisk=<PDISKID> action=clear controller=id pdisk=<PDISKID> action=cancelclear controller=id pdisk=<PDISKID> action=enabledevicewritecache controller=id pdisk=<PDISKID> action=disabledevicewritecache controller=id pdisk=<PDISKID> action=exportreliabilitylog controller=id pdisk=<PDISKID> action=convertraidtononraid controller=id pdisk=<PDISKID> action=convertnonraidtoraid controller=id pdisk=<PDISKID>

145

Omconfig Blink Physical Disk

Description

Syntax

Example to

Example for SCSI, SATA, and ATA controllers

Example for SAS controllers

Blinks the light (light emitting diode or LED display) on one or more physical disks attached to a controller.

omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Blink physical disk 0 on connector 0 of controller

1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=blink controller=1 pdisk=0:0 omconfig storage pdisk action=blink controller=1 pdisk=0:2:0

Omconfig Unblink Physical Disk

Description

Syntax

Example to

Example for SCSI, SATA, and ATA controllers

Example for SAS controllers

Unblinks the light (light emitting diode or LED display) on one or more physical disks attached to a controller.

omconfig storage pdisk action=unblink controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Unblink physical disk 0 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=unblink controller=1 pdisk=0:0 omconfig storage pdisk action=unblink controller=1 pdisk=0:2:0

146

Omconfig Prepare To Remove Physical Disk

Table 86. Omconfig Prepare To Remove Physical Disk

Description

Prepares a physical disk for removal.

Syntax omconfig storage pdisk action=remove controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to

Example for SCSI, SATA, and ATA controllers

Prepares physical disk 3 on connector 0 of controller 1 for removal. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=remove controller=1 pdisk=0:3

Example for SAS controllers omconfig storage pdisk action=remove controller=1 pdisk=0:2:3

Omconfig Instant Erase Secured Physical Disk

Description Erases the given encrypted disk.

NOTE: This command is applicable only on

Micron devices.

Syntax

Example to

Example for SCSI, SATA, and ATA controllers omconfig storage pdisk action=instantsecureerase controller=id pdisk=<PDISKID>, where id is the controller ID.

The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Erase physical disk 3 on connector 0 of controller

1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=instantsecureerase controller=1 pdisk=0:3

147

Example for SAS controllers omconfig storage pdisk action=instantsecureerase controller=1 pdisk=0:2:3

Omconfig Cryptographic Erase Secured Physical Disk

Description Erases the given encrypted disk.

NOTE: This command is applicable only on

Non-Volatile Memory Express (NVMe) devices.

Syntax

Example to

Example for SCSI, SATA, and ATA controllers omconfig storage pdisk action=cryptographicerase controller=id pdisk=<PDISKID>, where id is the controller ID.

The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Erase physical disk 3 on connector 0 of controller

1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=cryptographicerase controller=1 pdisk=0:3

Example for SAS controllers omconfig storage pdisk action=cryptographicerase controller=1 pdisk=0:2:3

Omconfig Initialize Physical Disk

Description

Syntax

Example to

Initializes a physical disk.

omconfig storage pdisk action=initialize controller=id pdisk=id, where id is the controller ID and physical disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Initialize physical disk 4 on controller 1

148

Example omconfig storage pdisk action=initialize controller=1 pdisk=4

Omconfig Offline Physical Disk

Description

Syntax

Example to

Example for SCSI, SATA, and ATA controllers

Example for SAS controllers

Makes a physical disk offline.

omconfig storage pdisk action=offline controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Offline physical disk 3 on connector 0 of controller

1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=offline controller=1 pdisk=0:3 omconfig storage pdisk action=offline controller=1 pdisk=0:2:3

Omconfig Online Physical Disk

Description

Syntax

Example to

Example for SCSI, SATA, and ATA controllers

Example for SAS controllers

Brings an offline physical disk back online.

omconfig storage pdisk action=online controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Bring physical disk 3 on connector 0 of controller 1 back online. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=online controller=1 pdisk=0:3 omconfig storage pdisk action=online controller=1 pdisk=0:2:30

149

Omconfig Assign Global Hot Spare

Description

Syntax

Example to

Example for SCSI, SATA, and ATA controllers

Example for SAS controllers

Assigns a physical disk as a global hot spare.

omconfig storage pdisk action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=yes, where id is the controller ID. The

<PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Assign physical disk 3 on connector 0 of controller

1 as a global hot spare. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:3 assign=yes omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:2:3 assign=yes

Omconfig Rebuild Physical Disk

Description

Syntax

Example to

Example for SCSI, SATA, and ATA controllers

Rebuilds a failed physical disk. Rebuilding a disk may take several hours. If you need to cancel the rebuild, use the Cancel Rebuild task. For more information about Rebuild Physical Disk, see the

Dell OpenManage Online Help .

omconfig storage pdisk action=rebuild controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Rebuild physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=rebuild controller=1 pdisk=0:3

150

Example for SAS controllers omconfig storage pdisk action=rebuild controller=1 pdisk=0:2:3

Omconfig Cancel Rebuild Physical Disk

Description

Syntax

Cancels a rebuild that is in progress. If you cancel a rebuild, the virtual disk remains in a degraded state.

For more information about Cancel Rebuild

Physical Disk, see the Dell OpenManage Online

Help .

omconfig storage pdisk action=cancelrebuild controller=id pdisk=<PDISKID>, where id is the controller ID.

The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to Cancel the rebuild of physical disk 3 on connector

0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

Example for SCSI, SATA, and ATA controllers

Example for SAS controllers omconfig storage pdisk action=cancelrebuild controller=1 pdisk=0:3 omconfig storage pdisk action=cancelrebuild controller=1 pdisk=0:2:3

Omconfig Cancel Replace Member

Description

Syntax

Example to

Cancels a replace member operation.

omconfig storage pdisk action=cancelreplacemember controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Cancel replace member operation on disk 0:0:1 which is connected to controller 0

151

Example omconfig storage pdisk action=cancelreplacemember controller=0 pdisk=0:0:1

Omconfig Clear Physical Disk

Description

Syntax

Example to

Example for SAS controllers

Clears data or a configuration from a physical disk.

omconfig storage pdisk action=clear controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Clear physical disk 3 on connector 0 of controller

1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=clear controller=1 pdisk=0:2:3

Omconfig Cancel Clear Physical Disk

Description

Syntax

Cancels a clear operation in progress on a physical disk.

omconfig storage pdisk action=cancelclear controller=id pdisk=<PDISKID>, where id is the controller ID.

The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to

Example for SCSI, SATA, and ATA controllers

Cancel the clear of physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=cancelclear controller=1 pdisk=0:2:3

152

Omconfig Enable Device Write Cache

Description

Syntax

Enables write cache on a physical disk for the PCIe

SSD controller.

omconfig storage pdisk action=enabledevicewritecache controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to

Example for SAS controllers

Enable write cache on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=enabledevicewritecache controller=1 pdisk=0:2:3

Omconfig Disable Device Write Cache

Description

Syntax

Disables write cache on a physical disk for the PCIe

SSD controller.

omconfig storage pdisk action=disabledevicewritecache controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to

Example for SAS controllers

Disable write cache on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=disabledevicewritecache controller=1 pdisk=0:2:3

153

Omconfig Export Reliability Log

Description

Syntax

Example to

Example for SAS controllers

Exports log on a physical disk or the PCIe SSD controller.

omconfig storage pdisk action=exportreliabilitylog controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Export log on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=exportreliabilitylog controller=1 pdisk=0:2:3

Omconfig Convert RAID To Non-RAID

Description

Converts RAID to non-RAID on a physical disk.

Syntax omconfig storage pdisk action=convertraidtononraid controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

NOTE: To convert multiple RAID to non-RAID on a given controller, use omconfig storage controller action=convertraidtononraid command. For more information, see

omconfig Convert Multiple RAID To Non-

RAID

.

Example to Convert RAID to non-RAID on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

154

Example for SAS controllers omconfig storage pdisk action=raidtononraid controller=1 pdisk=0:2:3

Omconfig Convert Non-RAID To RAID

Description

Converts non-RAID to RAID on a physical disk.

Syntax omconfig storage pdisk action=convertnonraidtoraid controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

NOTE: To convert multiple non-RAID to RAID on a given controller, use omconfig storage controller action=convertnonraidtoraid command. For more information, see

omconfig Convert Multiple Non-RAID To

RAID

.

Example to

Example for SAS controllers

Convert non-RAID to RAID on physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

omconfig storage pdisk action=nonraidtoraid controller=1 pdisk=0:2:3

Omconfig Virtual Disk Commands

The following table provides the omconfig command syntax required to execute virtual disk tasks.

CAUTION: The omconfig storage vdisk action=deletevdisk controller=id vdisk=id command deletes a virtual disk. Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk.

Table 87. Omconfig Manage Virtual Disk Commands

Required Command

Levels (1, 2, 3)

Optional name=value pairs omconfig storage vdisk action=checkconsistency controller=id vdisk=id action=cancelcheckconsistency controller=id vdisk=id action=pausecheckconsistency controller=id vdisk=id action=resumecheckconsistency controller=id vdisk=id

155

Required Command

Levels (1, 2, 3)

Optional name=value pairs action=checkconsistency controller=id vdisk=id action=blink controller=id vdisk=id action=unblink controller=id vdisk=id action=initialize controller=id vdisk=id action=fastinit controller=id vdisk=id [force=yes] action=slowinit controller=id vdisk=id [force=yes] action=cancelinitialize controller=id vdisk=id action=cancelbginitialize controller=id vdisk=id action=assigndedicatedhotspare controller=id vdisk=id pdisk=<PDISKID> assign=<yes | no> action=deletevdisk controller=id vdisk=id [force=yes] action=format controller=id vdisk=id action=reconfigure controller=id vdisk=id raid=<c | r0 | r1 | r1c | r5 | r10> pdisk=<PDISKID> [size=<size> vdcapacityexpansion=yes sizeinpercent=<1 to

100>] action=securevd controller=id vdisk=id action=clearvdbadblocks controller=id vdisk=id ction=changepolicy controller=id vdisk=id [readpolicy=<ra | nra | ara | rc | nrc> | writepolicy=<wb | wt | wc | nwc | fwb> | cachepolicy=<d | c> diskcachepolicy=<enabled | disabled>] action=replacememberdisk controller=id vdisk=id source=<PDISKID> destination=<PDISKID> action=rename controller=id vdisk=id action=enablefluidcache controller=id vdisk=id devicename=<string> cachepolicy=<wb | wt> action=disablefluidcache controller=id vdisk=id devicename=<string> action=reactivate controller=id vdisk=id devicename=<string>

Omconfig Check Consistency

Description

Syntax

Initiates a check consistency on a virtual disk. The check consistency task verifies the virtual disk’s redundant data.

omconfig storage vdisk action=checkconsistency controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

156

Example to

Example

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Run a check consistency on virtual disk 4 on controller 1.

omconfig storage vdisk action=checkconsistency controller=1 vdisk=4

Omconfig Cancel Check Consistency

Description

Cancels a check consistency while in progress.

Syntax omconfig storage vdisk action=cancelcheckconsistency controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Example to Cancel a check consistency on virtual disk 4 on controller 1.

Example omconfig storage vdisk action=cancelcheckconsistency controller=1 vdisk=4

Omconfig Pause Check Consistency

Description

Syntax

Pauses a check consistency while in progress. For more information, see the Dell OpenManage Online Help.

omconfig storage vdisk action=pausecheckconsistency controller=id vdisk=id , where id is the controller ID and virtual disk

ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Example to Pause a check consistency on virtual disk 4 on controller 1

Example omconfig storage vdisk action=pausecheckconsistency controller=1 vdisk=4

157

Omconfig Resume Check Consistency

Description

Resumes a check consistency after it has been paused.

Syntax omconfig storage vdisk action=resumecheckconsistency controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Example to Resume a check consistency on virtual disk 4 on controller 1.

Example omconfig storage vdisk action=resumecheckconsistency controller=1 vdisk=4

Omconfig Blink Virtual Disk

Description

Blinks the physical disks included in a virtual disk.

Syntax omconfig storage vdisk action=blink controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Example to

Example

Blink the physical disks in virtual disk 4 on controller 1.

omconfig storage vdisk action=blink controller=1 vdisk=4

Omconfig Unblink Virtual Disk

Description

Unblinks the physical disks included in a virtual disk.

Syntax omconfig storage vdisk action=unblink controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to Unblink the physical disks in virtual disk 4 on controller 1.

Example omconfig storage vdisk action=unblink controller=1 vdisk=4

158

Omconfig Initialize Virtual Disk

Description

Initializes a virtual disk.

Syntax omconfig storage vdisk action=initialize controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Example to Initialize virtual disk 4 on controller 1

Example omconfig storage vdisk action=initialize controller=1 vdisk=4

Omconfig Fast Initialize Virtual Disk

Description Fast initializes a virtual disk.

CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.

Syntax

Example to

Example omconfig storage vdisk action=fastinit controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

NOTE: In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage vdisk action=fastinit controller=id vdisk=id force=yes

Fast initialize virtual disk 4 on controller 1.

omconfig storage vdisk action=fastinit controller=1 vdisk=4

Omconfig Slow Initialize Virtualize Disk

Description Slow initializes a virtual disk.

159

Syntax

Example to

Example

CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.

omconfig storage vdisk action=slowinit controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

NOTE: In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage vdisk action=slowinit controller=id vdisk=id force=yes

Slow initialize virtual disk 4 on controller 1.

omconfig storage vdisk action=slowinit controller=1 vdisk=4

Omconfig Cancel Initialize Virtual Disk

Description Cancels the initialization of a virtual disk.

Syntax

Example to omconfig storage vdisk action=cancelinitialize controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Cancels the initialization of virtual disk 4 on controller 1.

Example omconfig storage vdisk action=cancelinitialize controller=id vdisk=id

Omconfig Cancel Background Initialize

Description Cancels the background initialization process on a virtual disk.

Syntax omconfig storage vdisk action=cancelbginitialize controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

160

Example to

Example

Cancel background initialization on virtual disk 4 on controller 1.

omconfig storage vdisk action=cancelbginitialize controller=1 vdisk=4

Omconfig Assign Dedicated Hot Spare

Description Assigns one or more physical disks to a virtual disk as a dedicated hot spare.

Syntax

Example to omconfig storage vdisk action=assigndedicatedhotspare controller=id vdisk=id pdisk=<PDISKID> assign=yes, where id is the controller ID and virtual disk ID as reported by the omreport command. The

<PDISK>variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks and physical disks attached to the controller.

Assign physical disk 3 on connector 0 of controller 1 as a dedicated hot spare to virtual disk 4. On a Serial Attached SCSI (SAS) controller, the physical disk resides in enclosure 2.

Example for SCSI,

SATA, and ATA controllers

Example for SAS controllers omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:3 assign=yes omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:2:3 assign=yes

Omconfig Delete Virtual Disk

Description Deletes a virtual disk.

CAUTION: Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk. You may receive a warning message if you attempt to delete the system or boot partition.

However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.

Syntax omconfig storage vdisk action=deletevdisk controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

161

Example to

Example

NOTE: In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage vdisk action=deletevdisk controller=id vdisk=id force=yes

Delete virtual disk 4 on controller 1 omconfig storage vdisk action=deletevdisk controller=1 vdisk=4

Omconfig Format Virtual Disk

Description Formats a virtual disk.

Syntax

Example to omconfig storage vdisk action=format controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Format virtual disk 4 on controller 1

Example omconfig storage vdisk action=format controller=1 vdisk=4

Omconfig Reconfiguring Virtual Disks

Description Reconfigures a virtual disk to change the virtual disk’s RAID level or increase its size by either adding physical disks or using the available free space. On some controllers, you can also remove physical disks.

NOTE: If you want to reconfigure with an additional physical disk, the physical disk must be of the supported bus protocol, media type, sector size, T10 Protection Information capability, and encryption capability.

Syntax

Example to omconfig storage vdisk action=reconfigure controller=id vdisk=id raid=<c| r0| r1| r1c| r5| r6| r10> pdisk=<PDISK>

[size=<size> vdcapacityexpansion=yes sizeinpercent=<1 to

100>], where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Reconfigure virtual disk 4 to a size of 800 MB, use RAID-5 and physical disks 0 through 3 on connector 0 of controller 1. On a SAS controller, the physical disks reside in enclosure 2.

162

Example for SCSI,

SATA, and ATA controllers

Example for SAS controllers

Example to

Example omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 size=800m pdisk=0:0,0:1,0:2,0:3 omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 pdisk=0:2:0,0:2:1,0:2:2,0:2:3

Increase the size of the virtual disk by 20 percent using the available free space, use RAID-5 and physical disks 0 through 3 on connector 0 of controller 1. On a

SAS controller, the physical disks reside in enclosure 2.

omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 pdisk=0:2:0,0:2:1,0:2:2,0:2:3 vdcapacityexpansion=yes sizeinpercent=20

NOTE: vdcapacityexpansion parameter is supported only on PERC H700 and PERC H800 controllers. If you set vdcapacityexpansion=yes, specify sizeinpercent. If you do not set vdcapacityexpansion, specify size.

Omconfig Secure Virtual Disk

Description Encrypts a virtual disk.

Syntax

Example to omconfig storage vdisk action=securevd controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Encrypt virtual disk 4 on controller 1.

Example omconfig storage vdisk action=securevd controller=1 vdisk=4

Omconfig Clear Virtual Disk Bad Blocks

Description Clears virtual disk bad blocks.

Syntax

Example to

Example omconfig storage vdisk action=clearvdbadblocks controller=id vdisk=id, where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Clear bad blocks on virtual disk 4 on controller 1.

omconfig storage vdisk action=clearvdbadblocks controller=1 vdisk=4

163

Omconfig Change Virtual Disk Policy

Description Changes a virtual disk’s read, write, or cache policy.

Syntax

Example to omconfig storage vdisk action=changepolicy controller=id vdisk=id [diskcachepolicy=<enabled|disabled> | readpolicy=<ra| nra| ara| rc|nrc> | writepolicy=<wb| wt| wc| nwc> | fwb> cachepolicy=<d | c>], where id is the controller ID and virtual disk ID as reported by the omreport command.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

For more information about the controller-specific diskcache, read, write, and cache policy, see the Dell OpenManage Online Help. For information on specifying these parameters using the omconfig command, see the following:

• [readpolicy=<ra | nra | ara | rc | nrc>] parameter (optional)

• [writepolicy=<wb | wt | wc | nwc | fwb>] parameter (optional)

• [cachepolicy=<d | c>] Parameter (optional)

• [diskcachepolicy=<enabled|disabled>] parameter (optional)

Change the read policy of virtual disk 4 on controller 1 to no-read-ahead.

Example omconfig storage vdisk action=changepolicy controller=1 vdisk=4 readpolicy=nra

Omconfig Replace Member Virtual Disk

Description Replaces the member of a given virtual disk with the destination disk.

Syntax

Example to

Example for SCSI,

SATA, and ATA

Ccntrollers

Example for SAS controllers omconfig storage vdisk action=replacememberdisk controller=id vdisk=id source=<PDISKID> destination=<PDISKID>, where id is the controller ID and virtual disk ID as reported by the omreport command. The

<PDISK> variable specifies the physical disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Replace physical disk 3 on connector 0 of controller 1 of virtual disk 4 with physical disk 5. On a Serial Attached SCSI (SAS) controller, the physical disk resides in enclosure 2.

omconfig storage vdisk action=replacememberdisk controller=1 vdisk=4 source=0:3 destination=0:5 omconfig storage vdisk action=replacememberdisk controller=1 vdisk=4 source=0:2:3 destination=0:2:5

164

Omconfig Rename Virtual Disk

Description Renames a virtual disk.

Syntax

Example to omconfig storage vdisk action=rename controller=id vdisk=id name=<string>, where id is the controller ID and virtual disk ID as reported by the omreport command and <string> is the new name for the virtual disk.

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Rename virtual disk 4 on controller 1 to vd4.

Example omconfig storage vdisk action=rename controller=1 vdisk=4 name=vd4

Omconfig Enable Fluid Cache on Virtual Disk

Description Enables fluid cache for the specified virtual disk.

NOTE: Enabling fluid cache creates a new fluid cache disk. You must use only the new fluid cache disk for all future data access. Data access to any of the corresponding virtual disk or caching its partitions may lead to data corruption.

Syntax

Example to

Example omconfig storage vdisk action=enablefluidcache controller=id vdisk=id devicename=<string> cachepolicy=<wb|wt>, where id is the controller ID and virtual disk ID as reported by the omreport command and

<string> is the device name of the virtual disk, wb is writeback, and wt is writethrough. To obtain the values for controller ID and virtual disk ID, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Enable fluid cache on virtual disk 4 on controller 1.

omconfig storage vdisk action=enablefluidcache controller=1 vdisk=4 devicename=/dev/sdb cacachepolicy=wb

Omconfig Disable Fluid Cache on Virtual Disk

Description Disables fluid cache for the specified virtual disk.

Syntax omconfig storage vdisk action=disablefluidcache controller=id vdisk=id devicename=<string>, where id is the controller ID and virtual disk ID as reported by the omreportcommand and <string> is the device name of the virtual disk. To obtain the values for controller ID and virtual disk ID, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

165

Example to

Example

Disable fluid cache on virtual disk 4 on controller 1.

omconfig storage vdisk action=disablefluidcache controller=1 vdisk=4 devicename=/dev/sdb

Omconfig Reactivate Fluid Cache on Virtual Disk

Description Reactivates the fluid cache for the specified virtual disk.

Syntax omconfig storage vdisk action=reactivate controller=id vdisk=id devicename=<string>, where id is the controller ID and virtual disk ID as reported by the omreportcommand and <string> is the device name of the virtual disk. To obtain the values for controller ID and virtual disk ID, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.

Example to

Example

Reactivate fluid cache on virtual disk 4 on controller 1 omconfig storage vdisk action=reactivate controller= 1 vdisk=4 devicename=/dev/sdb

Omconfig Controller Commands

The following table provides the omconfig command syntax required to execute controller tasks.

CAUTION: The omconfig storage controller action=resetconfig controller=id resets the controller configuration. Resetting the controller configuration permanently destroys all data on all virtual disks attached to the controller. System or boot partition residing on these virtual disks is destroyed.

Table 88. Omconfig Controller Commands

Required Command Levels

(1, 2, 3)

Optional name=value pairs omconfig storage controller action=rescan controller=id action=enablealarm controller=id action=disablealarm controller=id action=quietalarm controller=id action=testalarm controller=id action=resetconfig controller=id [force=yes] action=createvdisk controller=id raid=<c | r0 | r1| r1c | r5 | r6 | r10 | r50 | r60> size=<number | b | m | g | max | min> pdisk=<PDISKID> [stripesize=<

2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb | 256kb | 512kb | 1mb >]

[cachepolicy=<d | c>] [readpolicy=<ra | nra | ara | rc | nrc>]

[writepolicy=<wb | wt | wc | nwc | fwb>] [diskcachepolicy=<disabled |

166

Required Command Levels

(1, 2, 3)

Optional name=value pairs enabled>] [name=<string>] [spanlength=<n>] | [secureflag=yes]

[vdpienabled=yes]

NOTE: For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is an optional parameter (default=2).

action=setrebuildrate controller=id rate=<0 to 100> action=setchangecontrollerproperties controller=<id> [bgirate=<rate>]

[reconstructrate=<rate>][checkconsistencyrate=<rate>]

[rebuildrate=<rate>][clearredundantpath=clear]

[abortcheckconsistencyonerror=<enabled/disabled>][loadbalance=<auto/ disabled>][allowrevertibilehotspareandreplacemember=enabled/disabled]

[autoreplacememberonpredictivefailure=<enabled/disabled>]

[persistenthotspare=enabled/disabled]rate=<0 to 100> action=discardpreservedcache controller=id force=<enabled/disabled> action=createsecuritykey controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes] [filepath=<Absolute path to the escrow file>]

NOTE: If you set escrow=yes, specify the escrow file path.

action=changesecuritykey controller=id keyid=<keyid> passphrase=<passphrase string> oldpassphrase=<oldpassphrase string>

[escrow=yes] [filepath=<Absolute path to the escrow file>]

NOTE: If you set escrow=yes, specify the escrow file path.

action=deletesecuritykey controller=id action=setbgirate controller=id rate=<0 to 100 > action=setreconstructrate controller=id rate=<0 to 100> action=setcheckconsistencyrate controller=id rate=<0 to 100> action=exportlog controller=id action=importsecureforeignconfig controller=id passphrase=<passphrase for imported foreign configuration> action=importforeignconfig controller=id action=importrecoverforeignconfig controller=id action=clearforeignconfig controller=id action=setpdiskpwrmanagement controller=id spindownunconfigureddrives=<enabled/disabled> spindownhotspares=<enabled/disabled> spindownconfigureddrives=<enabled/disabled> idlec=<enabled/disabled> spindowntimeinterval=<30 to 1440>(minutes) spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval=<1 to 24>(hours)

167

Required Command Levels

(1, 2, 3)

Optional name=value pairs

NOTE: Specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives=enabled.

action=setpatrolreadmode controller=id mode=<manual | auto | disable> action=startpatrolread controller=id action=stoppatrolread controller=id action=createcachecade controller=id pdisk=<PDISKID> [name=<string>] action=enablelkm controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes] [filepath=<Absolute path to the escrow file>]

NOTE: If you set escrow=yes, specify the escrow file path.

action=switchtolkm controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes] [filepath=<Absolute path to the escrow file>]

NOTE: If you set escrow=yes, specify the escrow file path.

action=rekeylkm controller=id action=convertraidtononraid controller=id pdisk=<PDISKID> action=convertnonraidtoraid controller=id pdisk=<PDISKID>

Omconfig Rescan Controller

Description Rescans a controller. For more information, see the Dell OpenManage Online

Help .

Syntax

Example to omconfig storage controller action=rescan controller=id, where id is the controller ID as reported by the omreport storage controller command.

Rescan controller 1.

Example omconfig storage controller action=rescan controller=1

NOTE: The rescan controller is not supported on non-RAID SCSI and SAS controllers. Reboot the system to make the configuration changes visible on non-RAID SCSI controllers.

Omconfig Enable Controller Alarm

Description Enables the controller alarm. For more information, see the Dell OpenManage

Online Help .

Syntax omconfig storage controller action=enablealarm controller=id, where id is the controller ID as reported by the omreport storage controller command.

168

Example to

Example

Enable the alarm on controller 1.

omconfig storage controller action=enablealarm controller=1

Omconfig Disable Controller Alarm

Description Disables the controller alarm. For more information, see the Dell OpenManage

Online Help .

Syntax

Example to omconfig storage controller action=enablealarm controller=id, where id is the controller ID as reported by the omreport storage controller command.

Disable the alarm on controller 1.

Example omconfig storage controller action=disablealarm controller=1

Omconfig Quiet Controller Alarm

Table 89. omconfig Quiet Controller Alarm

Description Silences an activated controller alarm. For more information, see the Dell

OpenManage Online Help.

Syntax

Example to omconfig storage controller action=quietalarm controller=id, where id is the controller ID as reported by the omreport storage controller command.

Quiet the alarm on controller 1.

Example omconfig storage controller action=quietalarm controller=1

omconfig Test Controller Alarm

Table 90. omconfig Test Controller Alarm

Description Tests the functionality of the controller alarm. The alarm sounds for about two seconds. For more information, see Dell OpenManage Online Help.

Syntax

Example to omconfig storage controller action=testalarm controller=id , where id is the controller ID as reported by the omreport storage controller command.

Test the alarm on controller 1.

Example omconfig storage controller action=testalarm controller=1

169

Omconfig Reset Controller Configuration

Description Resets the controller configuration.

CAUTION: Resetting a configuration permanently destroys all data on all virtual disks attached to the controller. System or boot partition residing on these virtual disks is destroyed. You may receive a warning message if this command results in deleting the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.

Syntax

Example to omconfig storage controller action=resetconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.

In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage controller action=resetconfig controller=id force=yes

Reset the configuration on controller 1.

Example omconfig storage controller action=resetconfig controller=1

omconfig Create Virtual Disk

The Dell OpenManage Online Help provides additional information about creating virtual disks.

The omconfig syntax for creating a virtual disk has several parameters. You must specify the following parameters:

• Controller (controller=id)

• RAID level (raid=<c| r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>

• Size (size=<number | max | min>)>

Physical disk is specified as either:

• For SCSI, SATA, and ATA controllers: pdisk=connector:enclosureID:targetID where connector:enclosureID:targetID is the connector number, enclosure number, and slot number.

• For SAS controllers: pdisk=connector:targetID where connectorID:targetID is the connector number and the slot number. For example, pdisk=0:2

Storage Management supplies default values for any of the other parameters that you do not specify.

170

For creating an encrypted virtual disk, specify secureflag=yes. You can create encrypted virtual disks only with SED drives.

Complete Syntax: omconfig storage controller action=createvdisk controller=id raid=<c| r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>size=<number | max | min> pdisk=<PDISKID>

[stripesize=stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb | 128kb>]

[cachepolicy=<d | c>] [diskcachepolicy=<disabled | enabled>][readpolicy=<ra | nra | ara | rc | nrc>] [writepolicy=<wb| wt| wc| nwc | fwb>] [name=<string>]

[spanlength=<n>] | [secureflag=yes][vdpienabled=yes]

NOTE: If you are configuring RAID for SAS controllers with firmware version 6.1 and later, spanlength is an optional parameter (default=2). Spanlength is an even number and is lesser than or equal to half the number of physical disks specified in size.

NOTE: The vdpienabled is an optional argument and is valid only on PERC9 controllers. If set to yes a T10 Protection Information (PI) enabled virtual disk is created.

NOTE: For RAID 10 creation, PERC 9 firmware suggests the layout (number of array disks) with uneven span (spans with unequal number of array disks), though in a span the number of disks remains even. For example, for 32 disks, RAID 10 gets created with all the disks in one span and for

34 disks, RAID 10 gets created with 16 disks in one span and 18 disks in the other span.

Example Syntax:

You can create a RAID-5 virtual disk of 500 MB with a stripe size of 16 KB on a PERC 3/QC controller. The name of the virtual disk is vd1 and it resides on connector 0 of controller 1. Because the virtual disk is a

RAID-5, it requires at least three physical disks. In this example, you specify four physical disks. These are physical disks 0 through 3. The virtual disk has read-ahead, write–through caching, and cache I/O policies.

To create a virtual disk: omconfig storage controller action=createvdisk controller=1 raid=r5 size=500m pdisk= 0:0,0:1,0:2,0:3 stripesize=16kb cachepolicy=c readpolicy=ra writepolicy=wt

The only parameters that require specification are for the controller, RAID level, virtual disk size, and physical disk selection. Storage Management supplies default values for all other unspecified parameters.

For more information on read, write, and cache policies that are supported by the controller, see the Dell

OpenManage Online Help.

Parameter Specification For Creating And Reconfiguring Virtual Disk

The following table displays how to specify the omconfig storage controller action=createvdisk parameters:

Table 91. Parameters And Types

Parameters controller=id raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> size=<number | max | min>

Type

Required

Required

Required

171

Parameters pdisk=<connector:targetID,connector:targetID,.....

>

[stripesize=<2k b| 4kb | 8kb | 16kb | 32kb | 64kb |

128kb>]

[cachepolicy=<d | c>]

[readpolicy=<ra | nra | ara | rc | nrc>]

[writepolicy=<wb | wt | wc | nwc | fwb>]

[name=<string>]

[spanlength=<n>] parameter

Type

Required

Optional

Optional

Optional

Optional

Optional

Optional controller=id parameter

Specify the controller ID as reported by the omreport storage controller command. For example,controller=2 raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>

Use the raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> parameter to specify concatenation or a RAID level for a virtual disk. Different controllers support different RAID levels. For more information about RAID levels a controller supports and for general information about RAID levels and concatenation, see the Dell

OpenManage Online Help. The following table displays how to specify the raid=n parameter for each

RAID level and concatenation.

Table 92. Raid Level And Concatenation

RAID Level or Concatenation

RAID-0

RAID-1

RAID-5

RAID-6

RAID-10

RAID-50

RAID-60

RAID-1-concatenated

Concatenation raid=n Parameter Specification raid=r0 raid=r1 raid=r5 raid=r6 raid=r10 raid=r50 raid=r60 raid=r1c raid=c size=<number | max | min>

The following table displays how to specify the size=<number | max | min>

172

Table 93. Size Parameter size=<number | max | min> Parameter

Specification size=<n>

Description size=max size=min

Use this specification to indicate a specific size for the virtual disk. The virtual disk size is specified in b

(bytes), m (megabytes), or g (gigabytes). For example, size=500m indicates that the virtual disk is 500 MB.

To create a virtual disk that is the maximum size possible, specify size=max. When creating a

RAID-50 virtual disk, this parameter is specified as size=max.

To create a virtual disk that is the minimum size possible, specify size=min.

PDISKID=<connector:enclosureID:targetID | connector:targetID>

Use this parameter to specify the physical disks to be included in the virtual disk.

When reconfiguring a virtual disk, you must specify all physical disks to include in the reconfigured virtual disk. The physical disk specification applies to physical disks in the original virtual disk and continues in the reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk.

Some controllers allow you to remove a physical disk from a virtual disk. In this case, do not specify to remove the physical disk.

The pdisk=<PDISKID> parameter indicates a physical disk by specifying either connector:enclosureID:targetID or connector:targetID.

stripesize=<2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb>

Different controllers support different stripe sizes. For more information on stripe sizes supported for a controller, see the Dell OpenManage Online Help. All stripe sizes are specified in kilobytes. For example, when specifying 128 KB as the stripe size, type: stripesize=128kb cachepolicy=<d | c>] parameter

Different controllers support different cache policies. The following table displays how to specify the

[cachepolicy=<d | c>] parameter for each of the cache policies.

Table 94. Cache Policy Parameters

Cache Policy

Direct I/O

Cache I/O cachepolicy=d | c Parameter Specification cachepolicy=d cachepolicy=c diskcachepolicy=<disabled | enabled>

Different controllers support different disk cache policies. The following table indicates how to specify the [diskcachepolicy=<disabled | enabled>] parameter for each of the cache policies.

173

Table 95. Disk Cache Policy Parameters

Disk Cache Policy

Disabled

Enabled diskcachepolicy=disabled | enabled Parameter

Specification diskcachepolicy=disabled diskcachepolicy=enabled readpolicy=ra | nra | ara | rc | nrc>

Different controllers support different read policies. The following table displays how to specify the readpolicy=<ra | nra | ara | rc | nrc> parameter for each of the read policies.

Table 96. Read Policy Parameters

Read Policy

Read ahead

Adaptive read ahead

No read ahead

Read cache

No read cache readpolicy=ra | ara | nra | rc | nrc Parameter

Specification readpolicy=ra readpolicy=ara readpolicy=nra readpolicy=rc readpolicy=nrc writepolicy=<wb | wt | wc | nwc>]

Different controllers support different write policies. The following table displays how to specify the writepolicy=<wb | wt | wc | nwc | fwb> parameter for each of the write policies.

Table 97. Write Policy Parameters

Write Policy

Write-back cache

Write-through cache

Write cache

Force write back

No write cache writepolicy=wb | wt | wc | fwb | nwc Parameter

Specification writepolicy=wb writepolicy=wt writepolicy=wc writepolicy=fwb writepolicy=nwc

Controller=id

Specify the controller ID as reported by the omreport storage controller command. For example, controller=2

Raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60>

Use the raid=<c| r0 | r1| r1c | r5 | r6 | r10 | r50 | r60> parameter to specify concatenation or a RAID level for a virtual disk. Different controllers support different RAID levels. For more information about RAID levels a controller supports and for general information about RAID levels and concatenation, see the Dell

OpenManage Online Help. The following table displays how to specify the raid=n parameter for each

RAID level and concatenation.

174

Table 98. Raid Level And Concatenation

RAID Level or Concatenation

RAID-0

RAID-1

RAID-5

RAID-6

RAID-10

RAID-50

RAID-60

RAID-1-concatenated

Concatenation raid=n Parameter Specification raid=r0 raid=r1 raid=r5 raid=r6 raid=r10 raid=r50 raid=r60 raid=r1c raid=c size=<number | max | min> Parameter

The following table displays how to specify the size=<number | max | min>

Table 99. Size Parameter size=<number | max | min> Parameter

Specification size=<n>

Description size=max size=min

Use this specification to indicate a specific size for the virtual disk. The virtual disk size is specified in b

(bytes), m (megabytes), or g (gigabytes). For example, size=500m indicates that the virtual disk is 500 MB.

To create a virtual disk that is the maximum size possible, specify size=max. When creating a

RAID-50 virtual disk, this parameter is specified as size=max.

To create a virtual disk that is the minimum size possible, specify size=min.

stripesize=< 2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb> stripesize=<2kb | 4kb | 8kb | 16kb | 32kb | 64kb | 128kb>

Different controllers support different stripe sizes. For more information on stripe sizes supported for a controller, see the Dell OpenManage Online Help. All stripe sizes are specified in kilobytes. For example, when specifying 128 KB as the stripe size, type: stripesize=128kb

PDISKID=<connector:enclosureID:targetID | connector:targetID>

PDISKID=<connector:enclosureID:targetID | connector:targetID>

Use this parameter to specify the physical disks to be included in the virtual disk.

175

When reconfiguring a virtual disk, you must specify all physical disks to include in the reconfigured virtual disk. The physical disk specification applies to physical disks in the original virtual disk and continues in the reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk.

Some controllers allow you to remove a physical disk from a virtual disk. In this case, do not specify to remove the physical disk.

The pdisk=<PDISKID> parameter indicates a physical disk by specifying either connector:enclosureID:targetID or connector:targetID.

Cachepolicy=<d | c> cachepolicy=<d | c>] Parameter

Different controllers support different cache policies. The following table displays how to specify the

[cachepolicy=<d | c>] parameter for each of the cache policies.

Table 100. Cache Policy Parameters

Cache Policy

Direct I/O

Cache I/O cachepolicy=d | c Parameter Specification cachepolicy=d cachepolicy=c

Diskcachepolicy=<disabled | enabled>

Different controllers support different disk cache policies. The following table indicates how to specify the [diskcachepolicy=<disabled | enabled>] parameter for each of the cache policies.

Table 101. Disk Cache Policy Parameters

Disk Cache Policy

Disabled

Enabled diskcachepolicy=disabled | enabled Parameter

Specification diskcachepolicy=disabled diskcachepolicy=enabled

Readpolicy=<ra | nra | ara | rc | nrc>]

Different controllers support different read policies. The following table displays how to specify the readpolicy=<ra | nra | ara | rc | nrc> parameter for each of the read policies.

Table 102. Read Policy Parameters

Read Policy

Read ahead

Adaptive read ahead

No read ahead

Read cache

No read cache readpolicy=ra | ara | nra | rc | nrc Parameter

Specification readpolicy=ra readpolicy=ara readpolicy=nra readpolicy=rc readpolicy=nrc

176

Writepolicy=<wb | wt | wc | nwc>

Different controllers support different write policies. The following table displays how to specify the writepolicy=<wb | wt | wc | nwc | fwb> parameter for each of the write policies.

Table 103. Write Policy Parameters

Write Policy

Write-back cache

Write-through cache

Write cache

Force write back

No write cache writepolicy=wb | wt | wc | fwb | nwc Parameter

Specification writepolicy=wb writepolicy=wt writepolicy=wc writepolicy=fwb writepolicy=nwc name=<string>

Use this parameter to specify a name for the virtual disk. For example:name=VirtualDisk1 spanlength=<n> (Required For RAID 50 And RAID 60 And Optional For RAID 10)

Use this parameter to specify the number of physical disks in each stripe. This parameter applies only to

RAID-50 virtual disks. If you are not creating a RAID-50 virtual disk, do not specify this parameter. For example: spanlength=3

For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is optional. Also, you can now specify the spanlength as an even number with a maximum of 8 spans with 32 physical disks each.

For example: omconfig storage controller action=createvdisk controller=1 raid=r10 size=min pdisk= 1:1:0,1:1:1,1:1:3,1:1:4,1:1:6,1:1:7,1:1:8,1:1:9 spanlength=4

Omconfig Set Controller Rebuild Rate

Descriptio n

Sets the controller rebuild rate.

Syntax omconfig storage controller action=setrebuildrate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.

Example to

Set the rebuild rate to 50 on controller 1.

Example omconfig storage controller action=setrebuildrate controller=1 rate=50

177

omconfig Change Controller Properties

Table 104. omconfig Change Controller Properties

Description

Changes any or all of the controller properties.

Syntax omconfig storage controller action= setchangecontrollerproperties controller=<id> bgirate=<rate> reconstructrate=<rate> checkconsistencyrate=<rate> rebuildrate=<rate> clearredundantpath=clear abortcheckconsistencyonerror=<enabled | disabled> loadbalance=<auto | disabled> allowrevertiblehotspareandreplacemember

=<enabled | disabled> autoreplacememberonpredictivefailure=

<enabled | disabled> persistenthotspare=<enabled | disabled>

Example to Enable allow revertible hot spare and replace member operation.

Example omconfig storage controller action= setchangecontrollerproperties allowrevertiblehotspare andreplacemember=enabled controller=1

Omconfig Discard Preserved Cache

Descriptio n

Discards the preserved cache on the controller.

NOTE: To check if the controller has a preserved cache, type omreport storage controller controller=id. If the system displays Preserved Cache=yes, it indicates the presence of the preserved cache.

Syntax omconfig storage controller action= discardpreservedcache controller=id force=enabled | disabled

If you set force=enabled, the cache is discarded irrespective of whether the controller detects a foreign or an offline virtual disk.

Example to

Discard the preserved cache.

Example omconfig storage controller action= discardpreservedcache controller=1 force=enabled

CAUTION: Discarding the preserved cache can result in data loss. It is recommended that you run this command using the force=disabled option.

178

NOTE: If a foreign configuration is detected, then the preceding command using force=disabled option fails. To avoid data loss, import the foreign configuration and flush the preserved cache to disk. To discard preserved cache forcefully, either clear the foreign configuration and run the proceeding command, or run the proceeding command using force=enabled option.

Omconfig Create Encryption Key

Descriptio n

Creates the encryption key for the controller.

Syntax omconfig storage controller action= createsecuritykey controller=id keyid=<keyid string> passphrase=<passphrase string>[escrow= yes]

[filepath=<Absolute path to the escrow file>]

Example to

Create the encryption key for the controller.

Example omconfig storage controller action= createsecuritykey controller=1 keyid=Dell_123 passphrase=Dell_123 escrow=yes filepath= C:/escrow.xml

NOTE: If you set escrow=yes, specify the escrow file path.

Omconfig Change Encryption Key

Descriptio n

Changes the encryption key for the controller, if passphrase is provided.

Syntax omconfig storage controller action= changesecuritykey controller=id keyid=<keyid string> passphrase=passphrase string> oldpassphrase=<old passphrase string>[escrow=yes] [filepath=<Absolute path to the escrow file>]>

Example to

Change the encryption key for the controller.

Example omconfig storage controller action= changesecuritykey controller=1 keyid=Dell_123 passphrase=Dell_123 oldpassphrase=Dell_321 escrow= yes filepath=C:/escrow.xml

NOTE: If you set escrow=yes, specify the escrow file path.

Omconfig Delete Encryption Key

Descriptio n

Deletes the encryption key for the controller.

Syntax omconfig storage controller action= deletesecuritykey controller=id, where id is the controller ID as reported by the omreport storage controller command.

179

Example to

Change the encryption key for the controller.

Example omconfig storage controller action= deletesecuritykey controller=1

Omconfig Set Background Initialization Rate

Descriptio n

Sets the background initialization rate.

Syntax

Example to omconfig storage controller action=setbgirate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.

Sets the background initialization rate to 50 on controller 1.

Example omconfig storage controller action=setbgirate controller=1 rate=50

Omconfig Set Reconstruct Rate

Descriptio n

Sets the reconstruct rate.

Syntax omconfig storage controller action= setreconstructrate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.

Example to

Set the reconstruct rate to 50 on controller 1.

Example omconfig storage controller action= setreconstructrate controller=1 rate=50

Omconfig Set Check Consistency Rate

Descriptio n

Sets the check consistency rate.

Syntax omconfig storage controller action= setcheckconsistencyrate controller=id rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller command.

Example to

Sets the check consistency rate to 50 on controller 1.

Example omconfig storage controller action= setcheckconsistencyrate controller=1 rate=50

180

Omconfig Export The Controller Log

Descriptio n

Exports the controller log to a text file. For more information about the exported log file, see the Dell OpenManage Online Help.

Syntax

Example to omconfig storage controller action=exportlog controller=id, where id is the controller ID as reported by the omreport storage controller command.

Export the log on controller 1.

Example omconfig storage controller action=exportlog controller=1

By default, the log file is exported to C:\WINNT or C:\Windows on Microsoft Windows systems (based on the Windows version used) and /var/logon all Linux systems.

Depending on the controller, the log file name is afa_<mmdd>.log or lsi_<mmdd>.log where <mmdd> is the month and date. For more information on the controller log file, see the Dell OpenManage Online Help .

NOTE: The export log file command is not supported on the 4/IM, CERC ATA, and

100/4ch controllers.

Omconfig Import Secure Foreign Configuration

Descriptio n

Unlocks the encrypted Local Key Management (LKM) foreign configuration drives.

Syntax omconfig storage controller action= importsecureforeignconfig controller=id passphrase=<passphrase string for the foreign configuration>, where id is the controller ID as reported by the omreport storage controller command.

Example to

Unlock the ecncrypted LKM configuration drives on controller 1

Example omconfig storage controller action= importsecureforeignconfig controller=1 passphrase= Dell_123

Omconfig Import Foreign Configuration

Descriptio n

Imports all virtual disks that reside on physical disks newly attached to the controller.

Syntax omconfig storage controller action= importforeignconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.

NOTE: This command is supported only in firmware version 5.0.x.

Example to

Import foreign configurations on controller 1.

181

Example omconfig storage controller action= importforeignconfig controller=1

Omconfig Import Or Recover Foreign Configuration

Descriptio n

Imports and recovers all virtual disks that reside on physical disks newly attached to the controller.

Syntax omconfig storage controller action= importrecoverforeignconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.

NOTE: This command is supported only in firmware version 5.1.1.

Example to

Import foreign configurations on controller 1.

Example omconfig storage controller action= importrecoverforeignconfig controller=1

Omconfig Clear Foreign Configuration

Descriptio n

Clears or deletes all virtual disks that reside on physical disks newly attached to the controller.

Syntax omconfig storage controller action= clearforeignconfig controller=id, where id is the controller ID as reported by the omreport storage controller command.

NOTE: This command is supported only in firmware version 5.0.x.

Example to

Clear foreign configurations on controller 1.

Example omconfig storage controller action= clearforeignconfig controller=1

Omconfig Physical Disk Power Management

Descriptio n

Manages the power of physical disks in a controller by spinning down hot spares, configured drives, and unconfigured drives.

Syntax omconfig storage controller action= setpdiskpwrmanagement spindownunconfigureddrives= <enabled | disabled> spindownhotspares=<enabled | disabled> spindownconfigureddrives=<enabled | disabled> idlec=<enabled | disabled> spindowntimeinterval=<30 to 1440>(minutes) spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval= <1 to 24>(hours), where id is the controller ID as reported by the omreport storage controller command.

NOTE: On PERC 7 controllers, only spindownunconfigureddrives, spindownhotspares, and spindowntimeinterval parameters are supported.

182

NOTE: You can specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives=enabled.

Spin down drives that are not configured or hot spares that are unattended for 30 minutes Example to

Example omconfig storage controller action= setpdiskpwrmanagement spindownunconfigureddrives= enabled spindownhotspares=enabled spindowntimeinterval=30 controller=1

Omconfig Set Patrol Read Mode

Descriptio n

Sets the patrol read mode for the controller.

Syntax

Example to omconfig storage controller action= setpatrolreadmode controller=id mode= manual|auto|disable, where id is the controller ID as reported by the omreport storage controller command.

Sets the patrol read on controller 1 to manual mode

Example omconfig storage controller action= setpatrolreadmode controller=1 mode=manual

Omconfig Start Patrol Read

Descriptio n

Starts the patrol read task on the controller.

Syntax omconfig storage controller action=startpatrolread controller=id, where id is the controller ID as reported by the omreport storage controller command.

Start the patrol read task on controller 1.

Example to

Example omconfig storage controller action=startpatrolread controller=1

NOTE: To start patrol read, the current patrol read mode is set to Manual.

Omconfig Stop Patrol Read

Descriptio n

Stops the patrol read task on the controller.

Syntax omconfig storage controller action=stoppatrolread controller=id, where id is the controller ID as reported by the omreport storage controller command.

Example to

Stop the patrol read task on controller 1.

183

Example omconfig storage controller action=stoppatrolread controller=1

NOTE: To stop patrol read, the current patrol read mode is set to Manual.

Omconfig Create Cachecade

Descriptio n

Creates a cachecade on the given controller.

Syntax omconfig storage controller action=createcachecade controller=id pdisk=<PDISKID> [name=<string>] where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as: pdisk=connector:enclosureID:targetID | connector:targetID

Example to

Create a cachecade on controller 0.

Example omconfig storage controller action=createcachecade controller=0 pdisk=0:2:3 name=Cachecade1

Omconfig Enable LKM Controller

Descriptio n

Enables the LKM mode and creates the encryption key for the controller.

Syntax

Example to omconfig storage controller action=enablelkm controller=id keyid=<keyid string> passphrase= <passphrase string> [escrow=yes]

[filepath= <Absolute path to the escrow file>, where id is the controller ID as reported by the omreport storage controller command.

Create the encryption key for the controller.

Example omconfig storage controller action=enablelkm controller=1 keyid=Dell_123 passphrase=Dell_123 escrow= yes filepath=C:/escrow.xml

NOTE: If you set escrow=yes, specify the escrow file path.

Omconfig Rekey LKM Controller

Descriptio n

Re-keys the encryption key in LKM mode for the controller.

Syntax

Example to omconfig storage controller action=rekeylkm controller=id keyid=<keyid> passphrase=<passphrase string> escrow=yes filepath=<Absolute path to the escrow file>, where id is the controller ID as reported by the omreport storage controller command.

Re-key the encryption key for the controller.

184

Example omconfig storage controller action=rekeylkm controller=1

Omconfig Convert Multiple RAID To Non-RAID

Description Converts multiple RAID to non-RAID on the given controller.

Syntax

Example to

Example omconfig storage controller action=convertraidtononraid controller=id pdisk=<PDISKID>, where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk=connector:enclosureID:targetID | connector:targetID.

Convert multiple non-RAID to RAID on controller 0.

omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3

Omconfig Convert Multiple Non-RAID To RAID

Description Converts multiple non-RAID to RAID on the given controller.

Syntax

Example to

Example omconfig storage controller action=convertnonraidtoraid controller=id pdisk=<PDISKID>, where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk=connector:enclosureID:targetID | connector:targetID.

Convert multiple non-RAID to RAID on controller 0, omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3

Omconfig Enclosure Commands

The following table provides the omconfig command syntax required to execute enclosure tasks.

Table 105. Omconfig Enclosure Commands

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage enclosure action=enablealarm controller=id enclosure=<ENCLOSUREID> action=disablealarm controller=id enclosure=<ENCLOSUREID> action=setassettag controller=id enclosure=<ENCLOSUREID> assettag=<string> action=setassetname controller=id enclosure=<ENCLOSUREID> assetname=<string> action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n

185

Required Command

Levels (1, 2, 3)

Optional name=value pairs action=resettempprobes controller=id enclosure=<ENCLOSUREID> index=id action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n action=resetalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n action=blink controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n

Omconfig Enable Enclosure Alarm

Description Enables the enclosure alarm

Example to Enable the alarm on the enclosure attached to connector 2 on controller 1.

Example for SCSI,

SATA, and ATA controllers

Example for SAS controllers omconfig storage enclosure action=enablealarm controller=1 enclosure=2 omconfig storage enclosure action=enablealarm controller=1 enclosure=1:2

Omconfig Disable Enclosure Alarm

Table 106. Omconfig Disable Enclosure Alarm

Description Disables the enclosure alarm.

Syntax omconfig storage enclosure action=disablealarm controller=id enclosure=<ENCLOSUREID>, where idis the controller ID. The

<ENCLOSUREID> variable specifies the enclosure.

Disables the alarm on enclosure 2 attached to connector 1 on controller 1.

Example to

Example for SCSI,

SATA, and ATA controllers

Example for SAS controllers omconfig storage enclosure action=disablealarm controller=1 enclosure=2 omconfig storage enclosure action=disablealarm controller=1 enclosure=1:2

186

Omconfig Set Enclosure Asset Tag

Table 107. Omconfig Set Enclosure Asset Tag

Description Specifies the enclosure’s asset tag.

Syntax

Example to omconfig storage enclosure action=setassettag controller=id enclosure=<ENCLOSUREID> assettag=<string>, where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, <string> is a user-specified alphanumeric string.

Specify the asset tag to encl20 on the enclosure attached to connector 2 on controller.

Example for SCSI,

SATA, and ATA controllers

Example for SAS controllers omconfig storage enclosure action=setassettag controller=1 enclosure=2 assettag=encl20 omconfig storage enclosure action=setassettag controller=1 enclosure=1:2 assettag=encl20

Omconfig Set Enclosure Asset Name

Table 108. Omconfig Set Enclosure Asset Name

Description Specifies the asset name for an enclosure.

Syntax

Example to omconfig storage enclosure action=setassetname controller=id enclosure=<ENCLOSUREID> assetname=<string>, where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, <string> is a user-specified alphanumeric string.

Specify the asset name to encl43 for the enclosure attached to connector 2 on controller 1.

Example for SCSI,

SATA, and ATA controllers

Example for SAS controllers omconfig storage enclosure action=setassetname controller=1 enclosure=2 assetname=encl43 omconfig storage enclosure action=setassetname controller=1 enclosure=1:2 assetname=encl43

Omconfig Set Temperature Probe Thresholds

Table 109. Omconfig Set Temperature Probe Thresholds

Description Sets the minimum and maximum warning temperature thresholds for a specified temperature probe.

187

Syntax

Example to

Example for SCSI,

SATA, and ATA controllers

NOTE: This command is not supported on SAS controllers.

omconfig storage enclosure action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n, where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Set the temperature probe thresholds to 10 and 40 degree Celsius.

omconfig storage enclosure action=settempprobes controller=1 enclosure=2 index=3 minwarn=10 maxwarn=40

NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.

Omconfig Reset Temperature Probe Thresholds

Table 110. Omconfig Reset Temperature Probe Thresholds

Description Resets the minimum and maximum warning temperature thresholds back to their default values.

NOTE: This command is not supported on SAS controllers.

Syntax

Example to

Example for SCSI,

SATA, and ATA controllers omconfig storage enclosure action=resettempprobes controller=id enclosure=<ENCLOSUREID> index=id, where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Reset the thresholds for temperature probe 3, residing in the enclosure attached to connector 2 on controller 1, to the default values.

omconfig storage enclosure action=resettempprobes controller=1 enclosure=2 index=3

NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.

Omconfig Set All Temperature Probe Thresholds

Table 111. Omconfig Set All Temperature Probe Thresholds

Description Sets the minimum and maximum warning temperature thresholds for all temperature probes in the enclosure.

NOTE: This command is not supported on SCSI RAID controllers.

Syntax omconfig storage enclosure action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n,

188

Example to

Example for SAS controllers where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on controller 1, to 10 and 40 degree Celsius.

omconfig storage enclosure action=setalltempprobes controller=1 enclosure=2:3 minwarn=10 maxwarn=40

Omconfig Reset All Temperature Probe Thresholds

Table 112. oOmconfig Reset All Temperature Probe Thresholds

Description Resets the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure.

NOTE: This command is not supported on SCSI RAID controllers.

Syntax

Example to

Example for SAS controllers omconfig storage enclosure action=resetalltempprobes controller=id enclosure=<ENCLOSUREID>, where id is the controller ID.

The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1.

omconfig storage enclosure action= resetalltempprobes controller=1 enclosure=2:3

Omconfig Blink

Table 113. omconfig Blink

Description Blinks the light-emitting diodes (LEDs) on the enclosure.

Syntax omconfig storage enclosure action=blink controller=id enclosure=<ENCLOSUREID>, where id is the controller ID. The

<ENCLOSUREID> variable specifies the enclosure.

Example to

Example for SAS controllers

Example for SCSI,

SATA, and ATA controllers

Blink the LEDs for enclosure 3 attached to connector 2 on controller 1.

omconfig storage enclosure action=blink controller=1 enclosure=2:3 omconfig storage enclosure action=blink controller=1 enclosure=2

189

Omconfig Battery Commands

The following table displays the omconfig command syntax required to execute battery tasks.

Table 114. Omconfig Battery Commands

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage battery action=startlearn controller=id battery=id action=delaylearn controller=id battery=id days=d hours=h

omconfig Start Battery Learn Cycle

Table 115. Omconfig Start Battery Learn Cycle

Description Starts the battery learn cycle.

Syntax omconfig storage battery action=startlearn controller=id battery=id, where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=ID to display the ID for the controller battery.

Example to

Example

Start the learn cycle on controller 1.

omconfig storage battery action=startlearn controller=1 battery=0

Omconfig Delay Battery Learn Cycle

Table 116. Omconfig Delay Battery Learn Cycle

Description Delays the battery learn cycle for a specified period of time. You can delay the battery learn cycle for a maximum of seven days or 168 hours.

Syntax

Example to

Example omconfig storage battery action=delaylearn controller=id battery=id days=d hours=h, where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=ID to display the ID for the controller battery.

Delay the learn cycle for three days and 12 hours on controller 1.

omconfig storage battery action=delaylearn controller=1 battery=0 days=3 hours=12

190

Omconfig Global Commands

The following table displays the omconfig command syntax required to execute the global commands.

When executed, these commands apply to all controllers. These global commands also correspond to the global tasks provided by the Storage tree view object’s Information/Configuration subtab.

Table 117. Omconfig Global Commands

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage globalinfo action=enablests action=disablests action=globalrescan action=setprotectionpolicies type=ghs or dhs

Omconfig Global Enable Smart Thermal Shutdown

By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius. However, if you have implemented connector redundancy on the PV220S and PV221S enclosures you can specify that only the enclosure and not the operating system and server are shut down when the enclosure reaches a critical temperature of 0 or 50 degree

Celsius. Specifying that only the enclosure is shut down during excessive temperatures is known as Smart

Thermal Shutdown. For more information about Smart Thermal Shutdown, see the Dell OpenManage

Online Help.

Description

Syntax

Example to

Example

Enables smart thermal shutdown.

omconfig storage globalinfo action=enablests

Enable thermal shutdown. The omconfig command syntax for enabling thermal shutdown does not require a controller or enclosure ID.

NOTE: You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is also displayed by the

Server Administrator graphical user interface (GUI). To locate this status, select the Storage object and the Information/Configuration tab.

omconfig storage globalinfo action=enablests

Omconfig Global Disable Smart Thermal Shutdown

If you have previously enabled smart thermal shutdown using the omconfig command, you can disable smart thermal shutdown and return the system to its default setting. When smart thermal shutdown is disabled, the operating system and the server shuts down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius.

191

Description

Syntax

Example to

Example

Disables smart thermal shutdown for all controllers.

omconfig storage globalinfo action=disablests

Disable thermal shutdown. The omconfig command syntax for disabling thermal shutdown does not require a controller or enclosure ID.

NOTE: You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is also displayed in the GUI of Server Administrator. To locate this status, select the Storage object and the Information/Configuration tab.

omconfig storage globalinfo action=disablests

Omconfig Global Rescan Controller

Description Rescans all the controllers on the system. For more information about Global

Rescan Controller, see the Dell OpenManage Online Help.

Syntax omconfig storage globalinfo action=globalrescan

Example to

Example

Do a global rescan of all controllers. The omconfig command syntax for rescanning all controllers on the system does not require a controller or enclosure ID.

NOTE: Global rescan is not supported on non-RAID SCSI and SAS controllers. Reboot the system to make visible the configuration changes on non-RAID SCSI controllers.

omconfig storage globalinfo action=globalrescan

Omconfig Set Hot Spare Protection Policy

Table 118. Omconfig Set Hot Spare Protection Policy

Description Sets the hot spare protection policy for dedicated or global hot spares. For more information, see the Dell OpenManage Server Administrator Storage

Management User’s Guide at dell.com/support/manuals.

Syntax

Example for

Example omconfig storage globalinfo action= setprotectionpolicies type=dhs raid=<r1 | r5 | r6 | r10 | r50 | r60 | all> hscount=<1-16> warnlevel=<0-3> includeghsinvdstate=<yes | no>, where hscount is the number of hot spares assigned to the virtual disk and warnlevel is the severity level you want to assign to the generated alert, if this policy is violated. Use hscount=0 warnlevel=0 to reset the dedicated hot spare protection policy for the RAID level.

Global hot spare protection policy omconfig storage globalinfo action=setprotectionpolicies type=dhs hscount=1 warnlevel=1 includeghsinvdstate=yes

192

Omconfig Connector Commands

The following table displays the omconfig command syntax required to execute connector tasks.

Table 119. omconfig Connector Commands

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage connector action=rescan controller=id connector=id

Omconfig Rescan Connector

Description Rescans a controller connector. This command rescans all connectors on the controller and is therefore similar to performing a controller rescan.

NOTE: This command is not supported on SAS controllers.

Syntax

Example to

Example omconfig storage connector action=rescan controller=id connector=id, where id is the controller ID and the connector ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage connector controller=ID to display the IDs for the connectors attached to the controller.

Rescan connector 2 on controller 1.

omconfig storage connector action=rescan controller=1 connector=2

Omconfig Cachecade Commands

The following table displays the omconfig command syntax required to execute cachecade tasks.

Table 120. omconfig Cachecade Commands

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage cachecade action=blink controller=id cachecade=id action=unblink controller=id cachecade=id action=deletecachecade controller=id cachecade=id [force=yes] action=resize controller=id cachecade=id pdisk= <PDISKID> action=rename controller=id cachecade=id name=<string>

193

Omconfig Blink Cachecade

Description Blinks the physical disks included in a cachecade.

Syntax omconfig storage cachecade action=blink controller=id cachecade=id, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Example to

Example

Blinks the physical disk in cachecade 4 on controller 1 omconfig storage cachecade action=blink controller=1 cachecade=4

Omconfig Unblink Cachecade

Description Unblinks the physical disks included in a cachecade.

Syntax omconfig storage cachecade action=unblink controller=id cachecade=id, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Example to

Example

Unblinks the physical disk in cachecade 4 on controller 1 omconfig storage cachecade action=unblink controller=1 cachecade=4

Omconfig Delete Cachecade

Description Deletes a cachecade.

Syntax

Example to omconfig storage cachecade action=deletecachecade controller=id cachecade=id, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

In some circumstances, you may receive a warning message. You can override this warning by using the force=yes parameter. In this case, the syntax is as follows: omconfig storage cachecade action=deletecachecade controller=id cachecade=id force=yes

Delete cachecade 4 on controller 1.

194

Example omconfig storage cachecade action=deletecachecade controller=1 cachecade=4

Omconfig Resize Cachecade

Description Resizes a cachecade by adding or removing physical disks.

Syntax

Example to

Example for SAS controllers

Example for SCSI,

SATA, and ATA controllers omconfig storage cachecade action=resize controller=id cachecade=id pdisk=<PDISKID>, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Resize cachecade 4, use physical disks 0 through 3 on connector 0 of controller

1.

omconfig storage cachecade action=resize controller=1 cachecade=4 pdisk= 0:2:0,0:2:1,0:2:2,0:2:3 omconfig storage cachecade action=resize controller=1 cachecade=4 pdisk=0:0,0:1,0:2,0:3

Omconfig Rename Cachecade

Description Renames a cachecade.

Syntax

Example to

Example omconfig storage cachecade action=rename controller=id cachecade=id name=<string>, where id is the controller ID and the cachecade ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Rename cachecade 4 on controller 1 to cc4.

omconfig storage cachecade action=rename controller=1 cachecade=4 name=cc4

Omconfig PCIe SSD Commands

The following table displays the omconfig command syntax required to execute PCIe SSD tasks.

195

Table 121. omconfig PCIe SSD Commands

Required Command

Levels (1, 2, 3) omconfig storage pciessd

Optional name=value pairs action=addtocachepool subsystem=id pciedevice= <PDISKID> force=yes action=removefromcachepool subsystem=id pciedevice=<PDISKID> force=yes action=reactivate subsystem=id pciedevice= <PDISKID> force=yes

omconfig Add PCIe SSD Device To Cachepool

Description Adds the specified PCIe SSD device to the cache pool.

Syntax

Example to

Example omconfig storage pciessd action=addtocachepool subsystem=id pciedevice=<PDISKID>, where id is the subsystem ID and <PDISKID> variable specifies the physical disk. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Adds the specified PCIe SSD device to the cachepool.

omconfig storage pciessd action=addtocachepool subsystem=2 pciedevice=0:2:0 force=yes

Omconfig Add PCIe SSD Device To Cachepool

Description Removes the specified PCIe SSD device from the cache pool.

Syntax

Example to omconfig storage pciessd action=removefromcachepool subsystem=id pciedevice=<PDISKID>, where id is the subsystem ID and

<PDISKID> variable specifies the physical disk. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Remove the specified PCIe SSD device from the cachepool.

Example omconfig storage pciessd action=removefromcachepool subsystem=2 pciedevice=0:2:0 force=yes

Omconfig Reactivate PCIe SSD Device

Description Reactivates the specified PCIe SSD device that was part of the cache pool.

Syntax omconfig storage pciessd action=reactivate subsystem=id pciedevice=<PDISKID>, where id is the subsystem ID and <PDISKID> variable specifies the physical disk. To obtain these values, type omreport storage

196

Example to

Example controller to display the controller IDs and then type omreport storage cachecade controller=ID to display the IDs for the cachecades of the controller.

Reactivate the specified PCIe SSD device.

omconfig storage pciessd action=reactivate subsystem=2 pciedevice=0:2:0 force=yes

Omconfig Fluid Cache Commands

The following sections provide the omconfig command syntax required to execute fluid cache tasks.

Table 122. Omconfig Fluid Cache Commands

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage fluidcache action=applylicense licensefile=<filename> action=connect

Omconfig Applying Or Updating License To The Fluid Cache

Description Applies or upgrades the fluid cache license.

Syntax

Example to

Example omconfig storage fluidcache action=applylicense licensefile=<filename with absolute path>

Apply the fluid cache license.

omconfig storage fluidcache action=applylicense licensefile=/ root/key/licensefile.xml

Omconfig Conecting To The Fluid Cache

Description Connects to the fluid cache system and updates the cache configuration details of the storage subsystem.

Syntax omconfig storage fluidcache action=connect

Omconfig Partition Command

The following section provide the omconfig command syntax required to execute partition task.

197

Table 123. Omconfig Partition Command

Required Command

Levels (1, 2, 3) omconfig storage partition

Optional name=value pairs action=refresh

Omconfig Refreshing Partition List

Description Refreshes the partition list maintained in the storage subsytem.

Syntax omconfig storage partition action=refresh

Omconfig Fluid Cache Disk Command

The following section provide the omconfig command syntax required to execute the fluid cache disk task.

Table 124. Omconfig Fluid Cache Disk Command

Optional name=value pairs Required Command

Levels (1, 2, 3) omconfig storage fluidcachedisk action=disablewithdiscard fluidcachedisk= <string>

Omconfig Discarding Data And Disabling Caching

Description Discards the data on the cache and disable caching on the specified fluid cache disk.

Syntax

Example to

Example omconfig storage fluidcachedisk action= disablewithdiscard fluidcachedisk=<string>

Discard the data on the cache and disable caching on the fluid cache disk fcd1.

omconfig storage fluidcachedisk action= disablewithdiscard fluidcachedisk=fcd1

198

9

Working With CLI Command Results

Server Administrator Command Line Interface (CLI) users can use the command output in various ways.

This chapter explains how to save command output to a file and how to select a format for the command results that fits different objectives. The following table displays the systems on which omreport commands are applicable.

Table 125. System Availability For The omreport Command

Command Level 1 omreport

Command Level 2 modularenclosure servermodule mainsystem system chassis

Applicable To

Blade systems

Blade systems

Blade systems

Rack and Tower systems

Rack and Tower systems

Output Options For Command Results

CLI command output displays to standard output on the system in a command window, in an X-terminal, or on a screen, depending on the type of the operating system.

You can redirect command results to a file instead of displaying them to standard output. Saving command output to a file allows you to use the command output for later analysis or comparison.

Whether you display command results to standard output or have the command results written to a file, you can format the results. The format you select determines the way the command output is displayed and the way the command output is written to a file.

Controlling Command Output Display

Each operating system provides a means of controlling the way that command results display to standard output. The following is a useful command for ensuring that command results do not scroll by before you can view them. The same command syntax works for the Microsoft Windows command prompt, the

Red Hat Enterprise Linux terminal, and the SUSE Linux Enterprise Server terminal. To display command output with control over scrolling, type the CLI command and append the pipe symbol followed by more.

For example, type: omreport system summary | more or omreport servermodule summary | more

199

The multiscreen system summary displays the first screen. When you want to see the next screen of command output, press the spacebar.

Writing Command Output To A File

When redirecting command results to a file, you can specify a filename (and a directory path if necessary) to which you want to write the command result. When specifying the path to which you want to write the file, use the appropriate syntax for the operating system.

You can save command results in two ways. You can overwrite any file that has the same name as the output file you specify, or you can keep adding results of commands to a file of the same name.

Saving Command Results To A File That Is Overwritten

Use the -outc option when you want to overwrite data stored in previously written files. For example, at

11:00 A.M. you capture fan probe RPM readings for fan probe 0 on the system and write the results to a file called fans.txt. You type: omreport chassis fans index=0 -outc fans.txt

or omreport mainsystem fans index=0 -outc fans.txt

Partial results written to the file are:

Index

Status

Probe Name

Reading

Minimum Warning Threshold

Maximum Warning Threshold

Minimum Failure Threshold

Maximum Failure Threshold

: 0

: OK

: System Board Fan 1 RPM

: 2380RPM

: 600RPM

: 5700RPM

: 500RPM

: 6000RPM

Four hours later, you repeat the command. You have no interest in the 11:00 A.M. snapshot as written to fans.txt. You type the same command: omreport chassis fans index=0 -outc fans.txt

or omreport mainsystem fans index=0 -outc fans.txt

The 3:00 P.M. data overwrites the 11:00 A.M. data in the fans.txt file.

Fans.txt now reads as follows:

Index

Status

: 0

: OK

200

Probe Name

Reading

Minimum Warning Threshold

Maximum Warning Threshold

Minimum Failure Threshold

Maximum Failure Threshold

: System Board Fan 1 RPM

: 3001RPM

: 700RPM

: 5500RPM

: 500RPM

: 6000RPM

You cannot refer to the previous command results to compare the earlier fan probe 0 output with the present output because in using the -outc option, you overwrote the fans.txt file.

Append Command Results To An Existing File

Use the -outa option when you want to append new command results to data stored in a previously written file. For example, at 11:00 A.M. you capture fan probe RPM readings for fan probe 0 on the system and write the results to a file called fans.txt. To compare these results with output for the same probe obtained four hours later, you can use the -outa command to append the new output to fans.txt.

Type: omreport chassis fans index=0 -outa fans.txt

or omreport mainsystem fans index=0 -outa fans.txt

Fans.txt now reads as follows:

Index

Status

Probe Name

Reading

Minimum Warning

Threshold

Maximum Warning

Threshold

Minimum Failure

Threshold

Maximum Failure

Threshold

: 0

: OK

: System Board Fan 1 RPM

: 2380RPM

: 600RPM

: 5700RPM

: 500RPM

: 6000RPM

Index

Status

Probe Name

Reading

: 0

: OK

: System Board Fan 1 RPM

: 3622RPM

201

Minimum Warning

Threshold

Maximum Warning

Threshold

Minimum Failure

Threshold

Maximum Failure

Threshold

: 900RPM

: 3500RPM

: 500RPM

: 6000RPM

You can use a text editor to insert the time that each block of data was captured. In comparing the two snapshots for fan probe 0, you can see that the second report shows several changes. The reading of fan

RPM has increased by 621 RPM but is still within normal range. Someone has raised the minimum warning threshold by 200 RPM and has decreased the maximum warning threshold by 2000 RPM.

Selecting A Format For The CLI Command Output

You can specify a format for the CLI command results. The format determines how the command output is displayed. If the command results are directed to a file, the format is captured by the file to which you write the command results.

The available formats include:

• List (lst)

• Semicolon-separated values (ssv)

• Table (tbl)

• Custom delimited format (cdv)

The syntax for the formatting option is:

<command> -fmt <format option>

For example, type: omreport system summary -fmt tbl or omreport servermodule summary -fmt tbl where -fmt tbl specifies table format.

You can combine the formatting option with the option to direct output to a file. For example, type: omreport system summary -fmt tbl -outa summary.txt

or omreport servermodule summary -fmt tbl -outa summary.txt

where -fmt tbl specifies table format and -outa specifies that you append the command results to a file named summary.txt .

202

List (lst)

The default format is lst or list format. Use this format when you want to optimize output for simple readability. You need to specify a format for the command output only if you want a format other than the lst format.

To see the following example command output in lst format, type: omreport system summary or omreport servermodule summary

No special formatting option is required because list format is the default display format. The network data part of the example system summary is displayed as follows:

--------------

Network Data

--------------

Network Interface 0

IP Address : 143.166.152.108

Subnet Mask : 255.255.255.0

Default Gateway : 143.166.152.1

MAC Address : 00-02-b3-23-d2-ca

Table (tbl)

Use the tbl or table formatting option to have the data formatted in table rows and columns. To see the following example command output in table format, type: omreport system summary -fmt tbl or omreport servermodule summary -fmt tbl

The example output displays as follows:

------------------------------

Network Interface 0

------------------------------

| ATTRIBUTE | VALUE

| IP Address | 143.166.152.108

| Subnet Mask | 255.255.255.0

| Default Gateway | 143.166.152.1

| MAC Address | 00-02-b3-23-d2-ca

Semicolon-Separated Values (ssv)

Use the ssv formatting option to deliver output formatted in semicolon-separated value format. This format also allows you to import the command output results into a spreadsheet program such as

Microsoft Excel, or into a database program. To see the following example command output in semicolon-separated value format, type: omreport system summary -fmt ssv or omreport servermodule summary -fmt ssv

203

The example output displays as follows:

------------------------------

Network Data

------------------------------

Network Interface 0

IP Address;143.166.152.108

Subnet Mask;255.255.255.0

Default Gateway;143.166.152.1

MAC Address;00-02-b3-23-d2-ca

Custom Delimited Format (cdv)

Use the cdv formatting option to report exported data in custom delimited format. You can specify this option with any omreport command. For example, to generate a system summary in custom delimited format, type: omreport system summary -fmt cdv or omreport servermodule summary -fmt cdv

You can also set preferences for the custom delimited format with the omconfig command. The valid values for delimiters are: exclamation, semicolon, at, hash, dollar, percent, caret, asterisk, tilde, question, colon, comma, and pipe.

The following example shows how to set the delimiter for separating data fields to asterisk: omconfig preferences cdvformat delimiter=asterisk

204

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents