Compaq ALPHASERVER DS10 User Reference Manual
Compaq ALPHASERVER DS10 is a high-performance server designed for demanding business applications. It features a compact design, making it ideal for space-constrained environments. With its powerful processors, ample memory capacity, and support for various storage options, the Compaq ALPHASERVER DS10 can handle complex workloads efficiently. It also offers advanced management capabilities, allowing for remote monitoring and control, making it a reliable choice for businesses seeking a robust and versatile server solution.
Реклама
Реклама
EK–DS10S–UR. A01
A
LPHA
S
ERVER
DS10
USER REFERENCE CARD
This document is intended as a quick reference for the user. Additional information can be found in the AlphaServer DS10 / AlphaStation VS10 Console
Reference guide, EK-DS10S-CR.
Overview
•
Environmental Specifications
•
Mechanical Specifications
•
Electrical Specifications
•
Front Buttons and LEDs
•
Ethernet LEDs
•
Beep Codes
•
PCI Slots
•
Memory Configuration
•
SRM Console Commands
•
Remote Management Console
(RMC) Commands
•
Acoustics
WARNING: To prevent injury, access is limited to persons who have appropriate technical training and experience. Such persons are expected to understand the hazards of working within this equipment and take measures to minimize danger to themselves or others.
CPU modules and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before touching any module. Wear an antistatic wrist strap when working on this system.
© Digital Equipment Corporation 1999.
All rights reserved.
1
To reduce the risk of electrical shock or damage to the equipment: Do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. Disconnect power by unplugging the power cord from the electrical outlet or the workstation.
Environmental Specifications
Storage temperature range
Operating temperature range
–40º C to 66º C
(–40º F to 151º F)
10º C to 40º C
(50º F to 104º F)
Max. rate of change 11º C (20º F) per hour
Storage humidity range
(noncondensing)
10% to 90% relative humidity; maximum wet bulb 65º C
(149º F)
Operating humidity range
(noncondensing)
10% to 90% relative humidity
(without removable media) or
20% to 80% relative humidity
(with removable media); maximum wet bulb 2º C (36º F)
Max. altitude Nonoperating–4867 m (16,000 ft.);
Operating—2400 m (8,000 ft.)
Nonoperating shock 30 G, 25 ms halfsine
Mechanical Specifications
Leave ventilation room at the front and rear of the system.
PK1015
Height 13 cm (5 in.)
Width 43 cm (17 in.)
Depth 46 cm (18 in.)
Weight 14.5 kg (32 lb)
Electrical Specifications
•
Check your power supply setting.
•
Secure the power cord by turning the safety latch clockwise over the power cord. Secure the latch by tightening it with a screwdriver.
PK1047a
Front Buttons and LEDs
The LEDs are located in the lower right corner on the front of the system.
PK1043a
Symbol Function
Halt button . Open VMS, Tru64
UNIX: suspends the operating system and returns control to the SRM console.
Windows NT: resets the system.
Environmental amber LED. On indicates Temperature or Fan LEDs are on. Flashes when operating system invokes it as an alert.
Temperature amber LED. On indicates internal temperature exceeds operating conditions. The system shuts down 30 seconds after this LED lights.
Fan amber LED . On indicates at least one of the three fans in the system has failed. The system shuts down 30 seconds after this LED lights.
Disk Activity green LED. Flashes when internal system disks are accessed.
Power Present green LED. On when power is present in the system.
Power button. Push in to start the system and connect power. Push again to remove power and stop the system.
Ethernet LEDs
The Ethernet LEDs are on the back of the system, lower right corner.
PCI Slots
For OpenVMS and Tru64 UNIX systems, the SRM console command show config will display PCI information. For Windows NT system, see the
AlphaBIOS PCI Configuration screen.
Link
Speed/Activity
PCI Slot 4
PCI Slot 3
PCI Slot 2
PCI Slot 1
64 Bit
32 Bit
64 Bit
64 Bit
PK1050-99
LED Meaning
Link Steady green indicates Ethernet connection
Speed Green for Ethernet speed of 100
Amber for Ethernet speed of 10
Activity LED blinks with Ethernet activity
Beep Codes
The speaker in the front of the system reports errors using a series of beeps.
Beeps Meaning
1-2-3 Valid firmware image not found
4 Valid ROM header not found
6 Memory error (or bad checksum) detected
7 DIMMs in a memory bank do not match
PK1045-99
Memory Configuration
For OpenVMS and Tru64 UNIX systems, the SRM console command show memory displays the memory configura- tion. For Windows NT system, see the AlphaBIOS Memory Configuration screen.
DIMM
BANKS
1
0
1
0
DIMM CONFIGURATION RULES:
• Always fill at least one bank (0 or 1).
• Use the same two DIMMs within a bank (size and vendor).
PK1046a
2
SRM Console Commands alphabios Loads and starts the AlphaBIOS console.
boot Loads and starts the operating system.
clear envar Resets an environment variable to its default value.
clear password Sets the password to zero.
continue Resumes program execution.
crash Forces a crash dump at the operating system level.
deposit Writes data to the specified address.
edit Invokes the console line editor on a RAM file or on the nvram file (power-up script).
examine Displays the contents of a memory location, register, or device.
help Displays information about the specified console command.
initialize Resets the system to a known state.
lfu Runs the Loadable Firmware Update
Utility.
login Turns off secure mode, enabling access to all SRM console commands during the current session.
more Displays a file one screen at a time.
prcache Utility that initializes and displays status of the optional PCI NVRAM device.
set envar Sets or modifies the value of an environment variable.
set host Connects to an MSCP DUP server on a
DSSI device.
set password Sets the console password for the first time or changes an existing password.
set secure Enables secure mode without requiring a restart of the console.
show envar Displays the state of the specified environment variable.
show config Displays the configuration at the last system initialization.
show cpu Displays the state of each processor in the system.
show device Displays a list of controllers and their devices in the system.
show memory Displays memory module information.
show pal Displays the version of the privileged architecture library code (PALcode).
show power Displays information about the power supplies, system fans, CPU fans, and temperature.
show version Displays the version of the console program.
stop Halts the specified processor. (Same as
halt.) test Runs firmware diagnostics for the system.
Remote Management Console (RMC)
Commands alert_clr Clears alert flag, stopping dial-out alert cycle.
alert_dis Disables the dial-out alert function.
alert_ena Enables the dial-out alert function.
disable Disables remote access to the modem port.
enable Enables remote access to the modem port.
halt Halts the server.
haltin Causes a halt assertion.
haltout Terminates a halt assertion created with
haltin.
hangup Terminates the modem connection.
help or ? Displays the list of commands.
poweroff Turns off power.
poweron Turns on power.
quit Exits console mode and returns to system console port.
reset Resets the server. Emulates pressing the
Reset button.
setesc Changes the escape sequence for invoking command mode.
setpass Changes the modem access password.
status Displays system status and sensors.
3
4
Acoustics
Preliminary declared values per ISO 9296 and ISO 7779:
L
WAd
, B L pAm
, dBA
(bystander positions)
Idle Operate Idle Operate
with 0xHDD with RZ1DF
5.3
5.4
5.3
5.5
38
38
38
41
Current values for specific configurations are available from Compaq representatives. 1 B = 10 dBA.
Schallemissionswerte — Vorläufige Werteangaben nach
ISO 9296 und ISO 7779/DIN EN27779:
Schalleistungspegel
L
Wad
Leerlauf
, B
Schalldruckpege
L pAm
, dBA
( Zuschauerpositionen)
Betrieb Leerlauf Betrieb mit 0xHDD mit RZ1DF
5,3
5,4
5,3
5,5
38
38
38
41
Aktuelle Werte für speziele Ausrüstungsstufen sind uber die Compaq
Computer Vertretungen erhältelich. 1 B = 10 dBA.
For More Information
•
AlphaServer DS10 / AlphaStation VS10
Console Reference (EK-DS10S-CR)
•
AlphaServer DS10 Quick Setup
(EK-DS10S-CP)
•
Using a Web browser, follow links to the appropriate documentation from the URL: http://www.compaq.com/showroom/
Изтегляне
Реклама