Omron NT-series Operation Manual
PDF
Dokument
Annonce
Annonce
Cat No. V042-E1-1 PC CONNECTION Programmable Terminal OPERATION MANUAL PLC CONNECTION Programmable Terminal Operation Manual Produced April 1997 iii OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. The abbreviation “Host” means PC that controls NT20S. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note 1, 2, 3... Indicates information of particular interest for efficient and convenient operation of the product. 1. Indicates lists of one sort or another, such as procedures, checklists, etc. F Names of Devices and Tools PT Refers to an OMRON NT series programmable terminal. PC Refers to a Mitsubishi A series or FX series programmable controller. System installer Refers to an OMRON NT series system installer. Model NT30-ZS3AT-EMV1 NT620-ZS3AT-EMV1 Applicable PC Mitsubishi A series Mitsubishi FX series Mitsubishi A series © OMRON, 1997 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. v TABLE OF CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHAPTER 1 Connectable Hardware Combinations . . . . . . . . . . . . . . . . 1-1 1-2 1-3 Possible Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the System Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Usable Support Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHAPTER 2 Use with Mitsubishi A Series Computer Link Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-3 2-4 2-5 Usable PTs and PCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allocation Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specific Errors and Their Remedies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHAPTER 3 Use with Mitsubishi FX . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-4 Applicable PTs and PCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allocation Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X xi xi xi 1-1 1-2 1-3 1-4 2-1 2-2 2-4 2-10 2-17 2-21 3-1 3-2 3-3 3-6 3-8 APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APP-1 INDEX vii Related Manuals and Their Contents: The related manuals are indicated below. The * symbol at the end of the manual number is the revision history symbol. [Connections between the programmable terminal (PT) and programmable controllers (PC), etc.] This manual S PC Connection, Operation Manual . . . . . . . . . . . . . . . . . . . . . . V042-E1-j This Operation manual describes how to connect the programmable terminal (PT) to programmable controllers and other equipment, and how to make the settings required for these connections. [For information on NT series PT functions, operations, and restrictions] S NT20S Programmable Terminal Operation Manual . . . . . . . . V020-E1-j S NT600S Programmable Terminal Operation Manual . . . . . . . V022-E1-j S NT30/NT30C Programmable Terminal Operation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V034-E1-j S NT620S/NT620C Programmable Terminal Operation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V033-E1-j These manuals contain full descriptions of NT series PT functions, operations, and restrictions. viii How to Use the Manual This Operation Manual comprises the following Chapters. CHAPTER 1 Connectable Hardware Combinations This chapter describes the combinations of PT and programmable controller that can be connected. CHAPTER 2 Use with Mitsubishi A Series Computer Link Systems This chapter describes how to make the connections and settings when a PT is connected to a Mitsubishi A series programmable controller in a computer link system. CHAPTER 3 Use with Mitsubishi FX This chapter describes how to make the connections and settings when a PT is connected to a Mitsubishi FX series programmable controller. Appendix This chapter describes the specifications of the connectors of OMRON products used for communications. ix PRECAUTIONS This section provides general precautions for using the Programmable Terminal. The information contained in this section is important for the safe and reliable application of the Programmable Terminal. You must read this section and understand the information contained before attempting to set up or operate a Programmable Terminal. 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi x 1 Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). S Personnel in charge of installing FA systems. S Personnel in charge of designing FA systems. S Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and preformance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for using the Programmable Terminal. Be sure to read this manual before attempting to use the software and keep this manual close at hand for reference during operation. WARNING It is extremely important that Programmable Terminals related devices be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying Programmable Terminals to the abovementioned applications. WARNING Do not use input functions such as PT touch swiches for applications where danger to human life or serious damage is possible, or for emergency switch applications. 3 Safety Precautions In order to use this product safely and correctly, you must read and fully understand the “Safety Precautions” in the NT series Operation Manual before using it. Caution After connecting a communication cable, always secure it with the screws. Otherwise the cable may disconnect, causing operation to fail. xi CHAPTER 1 Connectable Hardware Combinations This chapter describes the connectable hardware combinations for each type of PT and each connection method. It also describes the types of system program used with NT30/NT30C, NT620S/NT620C. 1-1 Possible Combinations 1-1 Chapter 1-1 Possible Combinations The table below shows the combinations that can be connected. PT Type Model Connector Connection to Mitsubishi A (Computer Link) RS-232C RS-422A Connection to Mitsubishi FX (Programming console) NT20S NT20S-ST121-EV3 RS-232C f f NT600S NT600S-ST121-EV3 NT600S-ST211-EV3 RS-232C f NT30/NT30C (*1) NT30-ST131-E NT30C-ST141-E NT620S/NT620C (*1) NT620S-ST211-E NT620C-ST141-E RS-232C f f f RS-422A RS-232C f f: Direct connection Via RS-232C/RS-422A convertor unit : Connection not possible (*1) In order to use NT30/NT30C, NT620S/NT620C in multi-vendor systems, a dedicated system program must be installed in the PT using the “NT series system installer”. The relationship between the PCs that can be connected and the direct connection version is shown in the table below. 1-2 Connection to Mitsubishi A (Computer Link) Connection to Mitsubishi FX (Programming console) NT20S V4, V5 V4, V5 NT600S V4, V5 NT30/NT30C V4 NT620S/NT620C V1 to V4 V4 Installing the System Program 1-2 Chapter 1-2 Installing the System Program In order to use an NT30/NT30C or NT620S/NT620C in a multi-vendor system, a dedicated system program must be installed in the PT using the “NT series system installer” shown in the table below. Model Applicable PC NT30-ZS3AT-EMV1 Mitsubishi A series Mitsubishi FX series NT620-ZS3AT-EMV1 Mitsubishi A series For details on how to operate the system installer, refer to its instruction manual, or the PT Operation manual. Reference: Since NT20S and NT600S already have a dedicated system program written into them, this installation is not required for them. However, some PT models cannot be used in multi-vendor systems: check the situation for the model used by referring to “1-1 Possible Combinations” (page 1-2). 1-3 Usable Support Tools 1-3 Chapter 1-3 Usable Support Tools When using the PT in a multi-vendor system, one of the following support tools must be used. NT-ZA3AT-EV2 (Ver.2.3j) The programmable controllers (PC) that can be connected to the PT are determined by the “Direct Macn Type” data set in the screen data memory board. Accordingly, screen data complying with the programmable controller to be connected must be transferred to the PT in advance. The “Direct Macn Type” is set with the support tool. The applicable programmable controllers (PCs) depending on the “Direct Macn Type” setting are as follows. Direct Macn Type 1-4 Applicable Programmable Controller (PLC) NONE For connections without direct connection (e.g. RS-232C) OMRON For connection to an OMRON C series or CVM1/CV series PC, or for a memory link connection. MEL-A For connection to a Mitsubishi Electric MELSEC A series PC MEL-FX For connection to a Mitsubishi Electric FX series PC CHAPTER 2 Use with Mitsubishi A Series Computer Link Systems This chapter describes how to make the connections and settings when a PT is connected to a Mitsubishi A series programmable controller in a computer link system. 2-1 Usable PTs and PCs 2-1 Chapter 2-1 Usable PTs and PCs The PT, PC, and computer link module models that can be used in a computer link system that uses Mitsubishi A series PCs are indicated here. Usable PT Models The PT models that can be used with a computer link system that uses Mitsubishi A series PCs are tabled below. When using NT30/NT30C, NT620S/NT620C, install the system program for Mitsubishi A computer links in advance with the “NT series system installer”. PT Type Model NT20S NT20S-ST121j-EV3 NT600S NT600S-ST121j-EV3 NT600S-ST211j-EV3 NT30 NT30-ST131j-E NT30C NT30C-ST141j-E NT620S NT620S-ST211j-E NT620C NT620C-ST141j-E Reference: For the versions of the direct connection function that can be used, refer to “1-1 Possible Combinations” (page 1-2). For details on the direct connection function, refer to the Operation manual for the PT model used. 2-2 Usable PTs and PCs Chapter 2-1 Modules Mounted at the Connected PC Connections to a Mitsubishi A series PC are made at a computer link module. The table below lists the computer link modules to which the connection can be made with each type of connector. Series A series CPU Module A0J2CPU A0J2HCPU A1SCPU A1SJCPU A2SCPU A2USCPU A2USCPU-S1 A1NCPU A2NCPU A2NCPU-S1 A3NCPU A3HCPU A3MCPU A2ACPU A2ACPU-S1 A3ACPU A2UCPU A2UCPU-S1 A3UCPU Computer Link Module Used RS-232C RS-422 A0J2-C214S1 A1SJ71C24-R2 A1SJ71UC24-R2 A1SJ71C24-R4 A1SJ71UC24-R4 AJ71C24-S8 AJ71UC24 When the computer link module used is an AJ71C24-S8, A1SJ71C24-R2, or A1SJ71C24-R4, the device range is restricted to that usable with AnA models even if an AnU is used as the CPU module. To use an extended device range with AnU, an A1SJ71UC24-R2, A1SJ71UC24-R4, or AJ71UC24 must be used. 2-3 Connection 2-2 Chapter 2-2 Connection The NT20S, NT600S and NT620S/NT620C have an RS-232C connector, while the NT30/NT30C have an RS-232C connector and an RS-422A terminal block; some computer link modules have an RS-232C connector and some have an RS-422A terminal block. This section describes the methods for connection with these connectors and terminal block. Make cables that are suitable for the conditions of use, following the wiring details given in this section. Parts Required for Connection The connectors, connector covers, crimp terminals, and recommended cables for use with OMRON products are described here. For details on the connectors, connector covers, and crimp terminals used at the computer link module side, refer to the manual for the computer link module. F Parts for RS-232C (Common to PT and NT-AL001) Part Connector Connector cover Cable Model Remarks XM2A-0901 9-pin type, made by OMRON DE-9P 9-pin type, made by JAE XM2S-0911 9-pin type, made by OMRON DE-CI-J6 9-pin type, made by JAE AWG285P IFVV-SB Multi-core shielded cable, made by Fujikura, Ltd CO-MA-VV-SB 5P28AWG Multi-core shielded cable, made by Hitachi Cable, Ltd F Recommended Parts for RS-422A Terminal Block (for NT30/NT30C) <Appropriate crimp terminals> Fork type Round type 6.2 mm or less 6.2 mm or less Part Crimp terminal (M3.5) Cable 2-4 Model Remarks 2-YS3A Fork type, made by Japan Solderless Terminal MFG 2-YAS3.5 Fork type, made by Fuji Terminal 2Y-3.5 Fork type, made by Nichifu Terminal 2-3.5 Round type, made by Japan Solderless Terminal MFG V2-S3.5 Round type, made by Fuji Terminal 2-3.5 Round type, made by Nichifu Terminal H-9293A (CO-HC-ESV-3P7/0.2) Made by Hirakawa Hewtech corp. Connection Chapter 2-2 F Recommended Parts for RS-422A Terminal Blocks (For NTAL001) <Appropriate crimp terminals> Fork type Round type 6.2 mm or less 6.2 mm or less Part Crimp terminal (M3) (*1) Model Remarks Y1.25-3.5L Fork type, made by molex 1.25-N3A Fork type, made by Japan Solderless Terminal MFG (*1) Appropriate wire size: 0.3 to 0.75 mm2 Connection Between RS-232C (PT) and RS-232C (Computer Link) Computer link module PT Mitsubishi A series PC Host interface connector (RS-232C, 9-pin type) 9-pin connector 25-pin connector/ 9-pin connector Cable with RS-232C connector (maximum length: 15 m) Caution: After connecting a communication cable, always secure it with the screws. Otherwise the cable may disconnect, causing operation to fail. F Wiring When Computer Link Module has a 25-pin Connector There is a shielding wire at the computer link module side only: connect it to the connector cover and to the No.1 pin (FG). PT RS-232C interface Mitsubishi computer link module Abbrev. Pin No. Pin No. Abbrev. FG SD RD RS CS +5V 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 FG SD RD RS CS DR SG CD ER SG (9-pin) Shielding wire RS-232C interface (25-pin) 2-5 Connection Chapter 2-2 F Wiring When Computer Link Module has a 9-pin Connector PT RS-232C interface Mitsubishi computer link module Abbrev. Pin No. Pin No. Abbrev. FG SD RD RS CS +5V 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 CD RD SD ER SG DR RS CS SG Shielding wire (9-pin) RS-232C interface (9-pin) Connection Between RS-232C (PT) and RS-422A (Computer Link Module) Computer link module PT Mitsubishi A series PC 9-pin connector RS-232C/RS-422A convertor unit (NT-AL001) Host interface connector (RS-232C, 9-pin type) Cable with RS-232C connector (maximum length: 15 m) RS-422A terminal block RS-422A cable (maximum length: 500 m) 9-pin connector Caution: Note: After connecting a communication cable, always secure it with the screws. Otherwise the cable may disconnect, causing operation to fail. When connecting to a terminal block, always use crimp terminals. F Wiring Between PT and NT-AL001 PT Abbrev. RS-232C interface FG SD RD RS CS +5V SG (9-pin) 2-6 NT-AL001 RS-232C connector Pin No. 1 2 3 4 5 6 7 8 9 Pin No. Abbrev. Shielding wire Connector cover 2 3 4 5 6 7 8 9 SD RD RS CS +5V DR ER SG (9-pin) RS-232C interface Connection Chapter 2-2 F Wiring Between NT-AL001 and Computer Link Module Make the connections between SDB and SDA, and RDB and RDA, with twisted pair wires NT-AL001 RS-422A terminal block RS-422A interface Computer link module Abbrev. Pin No. Abbrev. CSA (–) CSB (+) RDA (–) RDB (+) SDA (–) SDB (+) SG GND 8 7 6 5 4 3 2 1 SDA (+) SDB (–) RDA (+) RDB (–) SG FG RS-422A interface Shielding wire Connection Between RS-422A (PT) and RS-422A (Computer Link Module) Computer link module PT Mitsubishi A series PC RS-422A terminal block RS-422A terminal block RS-422A cable (maximum length: 500 m) Note: When connecting to a terminal block, always use crimp terminals. F Wiring Make the connections between SDB and SDA, and RDB and RDA, with twisted pair wires. PT RS-422A terminal block RS-422A interface Computer link module Abbrev. Abbrev. SDA (–) SDB (+) RDA (–) RDB (+) SDA (+) SDB (–) RDA (+) RDB (–) SG FG Shielding wire RS-422A interface 2-7 Connection Chapter 2-2 Connection Between RS-422A (PT) and RS-232C (Computer Link) Computer link module PT Mitsubishi A series PC RS-422A terminal block RS-232C/RS-422A convertor unit (NT-AL001) RS-422A cable (maximum length: 500 m) 25-pin connector/ 9-pin connector Cable with RS-232C connector (maximum length: 15 m) 9-pin cable Caution: Note: After connecting a communication cable, always secure it with the screws. Otherwise the cable may disconnect, causing operation to fail. When connecting to a terminal block, always use crimp terminals. F Wiring Between PT and NT-AL001 Make the connections between SDB and SDA, and RDB and RDA, with twisted pair wires. PT RS-422A terminal block RS-422A interface NT-AL001 RS-422A terminal block Abbrev. Pin No. Abbrev. SDA (–) SDB (+) RDA (–) RDB (+) 8 7 6 5 4 3 2 1 CSA (–) CSB (+) RDA (–) RDB (+) SDA (–) SDB (+) SG GND Shielding wire 2-8 RS-422A interface Connection Chapter 2-2 F Wiring to NT-AL001 when Computer Link Module has 25-pin Connector Connect the power supply to the NT-AL001 (5 VDC) at pin No.6 (+5V) and pin No.9 (SG) of the RS-232C connector. NT-AL001 RS-232C connector Abbrev. Mitsubishi computer link module Pin No. Connector cover RS-232C interface SD RD RS CS +5V DR ER SG 2 3 4 5 6 7 8 9 Shielding wire (9-pin) Pin No. Abbrev. 1 2 3 4 5 6 7 8 9 FG SD RD RS CS DR SG CD ER RS-232C interface (25-pin) +5V 0V F Wiring to NT-AL001 when Computer Link Module has 9-pin Connector Connect the power supply to the NT-AL001 (5 VDC) at pin No.6 (+5V) and pin No.9 (SG) of the RS-232C connector. NT-AL001 RS-232C connector Abbrev. Mitsubishi computer link module Pin No. Connector cover RS-232C interface SD RD RS CS +5V DR ER SG (9-pin) 2 3 4 5 6 7 8 9 Shielding wire Pin No. Abbrev. 1 2 3 4 5 6 7 8 9 CD RD SD ER SG DR RS CS RS-232C interface (9-pin) +5V 0V 2-9 Setting 2-3 Chapter 2-3 Setting This chapter describes the settings required at each device in order to use a computer link system that uses Mitsubishi A series PCs. Settings at the PT Make the following settings in the PT’s maintenance mode by using the memory switches. When using NT30/NT30C or NT620S/NT620C, install the system program for Mitsubishi A computer links in advance using the “NT series system installer”. Reference: Set the other memory switches in accordance with the conditions of use. Item Setting Port select (NT30/NT30C only) RS-232C or RS-422 Comm. Type (*) Computer link Baud Rate 9600 bps or 19200 bps PC type AnN, AnA, or AnU *: The screen representation of the items to be set differs a little according to the PT model. For the “PC type” item, set the type of CPU module as follows. Setting AnN 2-10 CPU Module A0J2CPU A1SCPU A2SCPU A3NCPU A0J2HCPU A1SJCPU A2NCPU A3HCPU AnA A2ACPU A3ACPU A2ACPU-S1 AnU A2UCPU A2USCPU A3UCPU A2UCPU-S1 A2USCPU-S1 A2NCPU-S1 A3MCPU Setting Chapter 2-3 NT30/NT30C DIP switch settings When using RS-422A with NT30/NT30C, set DIP switches 2 to 8 to “ON” (terminal resistor used). Reference: Set the other DIP switches in accordance with the conditions of use. Settings for NT-AL001 When using the RS-232C/RS-422 convertor unit (NT-AL001), set the RS-422A communication conditions with the DIP switches as shown in the figure below. (Factory setting) [SW1-1] Not used (always ON) [SW1-2] ON Setting for built-in terminal resistor Terminal resistor used [SW1-3, 4] Selection of 2-wire type/4-wire type SW1-3 SW1-4 OFF 4-wire type ON [SW1-5, 6] Selection of RS-422A transmission mode SW1-5 SW1-6 OFF Transmission at any time ON 2-11 Setting Chapter 2-3 Computer Link Module Settings After connecting the PT and PC, set the conditions in the table below at the computer link module at the PC side. Set these conditions using the switches provided on each type of module by following the instructions given below. For a detailed explanation of the setting method, refer to the Operation Manual for each module. Item I/O port Baud rate Setting When using an RS-232C connector When using an RS-422A terminal block RS-232C RS-422A Set the same baud rate as set at the PT. ASCII 7 bits, 2 stop bits Transmission format Even Parity Control protocol Type 1 Unit No. (Station number) Type 5 00 <A0J2-C214S1> Unit No. (Station number) setting (SW3/SW4) Set both SW3 and SW4 to “0”. Transmission control protocol setting (SW5) When using an RS-232C connector, set to “1”. When using an RS-422A terminal block, set to “5”. Computer link/multidrop link selection (SW10) Set to “ON” (computer link). Main channel setting (SW11) When using an RS-232C connector, set to “OFF” (RS-232C). When using an RS-422A terminal block, set to “ON” (RS-422A). “Write during run” enable/disable setting (SW12) Set to “ON” (enabled). Transmission speed setting (SW13 to SW15) SW13 SW14 SW15 9,600bps ON OFF ON 19,200bps OFF ON ON Data length setting (SW16) Set to “OFF” (7 bits). Parity check yes/no setting (SW17) Set to “ON” (yes). Parity (odd/even) setting (SW18) Set to “ON” (even). Stop bit setting (SW19) Set to “ON” (2 bits). Sum check yes/no setting (SW20) Set to “ON” (yes). Transmission side terminal resistor present/absent setting (SW22) Set to “ON” (present) (setting invalid when RS-232C is used). Receiving side terminal resistor present/absent setting (SW23) Set to “ON” (present) (setting invalid when RS-232C is used). 2-12 Setting Chapter 2-3 <AJ71C24-S8> Unit No. (Station number) setting Set both switches to “0”. Transmission control protocol setting When using an RS-232C connector, set to “1”. When using an RS-422A terminal block, set to “5“. Main channel setting (SW11) When using an RS-232C connector, set to “OFF” (RS-232C). When using an RS-422A terminal block, set to “ON” (RS-422A). Data length setting (SW12) Set to “OFF” (7 bits). Transmission speed setting (SW13 to SW15) SW13 SW14 SW15 9,600bps ON OFF ON 19,200bps OFF ON ON Parity check yes/no setting (SW16) Set to “ON” (yes). Parity (odd/even) setting (SW17) Set to “ON” (even). Stop bit setting (SW18) Set to “ON” (2 bits). Sum check yes/no setting (SW21) Set to “ON” (yes). “Write during run” enable/disable setting (SW22) Set to “ON” (enabled). Transmission side terminal resistor present/absent setting (SW23) Set to “ON” (present) (setting invalid when RS-232C is used). Receiving side terminal resistor present/absent setting (SW24) Set to “ON” (present) (setting invalid when RS-232C is used). 2-13 Setting Chapter 2-3 <AJ71UC24> Transmission control protocol setting When using an RS-232C connector, set to “1”. When using an RS-422A terminal block, set to “5”. Unit No. (Station number) setting Set both switches to “0”. Main channel setting (SW11) When using an RS-232C connector, set to “OFF” (RS-232C). When using an RS-422A terminal block, set to “ON” (RS-422A). Data length setting (SW12) Set to “OFF” (7 bits). Transmission speed setting (SW13 to SW15) SW13 SW14 SW15 9,600bps ON OFF ON 19,200bps OFF ON ON Parity check yes/no setting (SW16) Set to “ON” (yes). Parity (odd/even) setting (SW17) Set to “ON” (even). Stop bit setting (SW18) Set to “ON” (2 bits). Sum check yes/no setting (SW21) Set to “ON” (yes). “Write during run” enable/disable setting (SW22) Set to “ON” (enabled). Computer link/multidrop link selection (SW23) Set to “ON” (computer link). 2-14 Setting Chapter 2-3 <A1SJ71UC24-R2, A1SJ71C24-R2> (RS-232C dedicated) Transmission control protocol setting Set to “1”. “Write during run” enable/disable setting (SW04) Set to “ON” (enabled). Transmission speed setting (SW05 to SW07) SW05 SW06 SW07 9,600bps ON OFF ON 19,200bps OFF ON ON Data length setting (SW08) Set to “OFF” (7 bits). Parity check yes/no setting (SW09) Set to “ON” (yes). Parity (odd/even) setting (SW10) Set to “ON” (even). Stop bit setting (SW11) Set to “ON” (2 bits). Sum check yes/no setting (SW12) Set to “ON” (yes). 2-15 Setting Chapter 2-3 <A1SJ71UC24-R4, A1SJ71C24-R4> (RS-422A dedicated) Unit No. (Station number) setting Set both switches to “0”. Transmission control protocol setting Set to “5”. Computer link/multidrop link selection (SW02) Set to “ON” (computer link). “Write during run” enable/disable setting (SW04) Set to “ON” (enabled). Transmission speed setting (SW05 to SW07) SW05 SW06 SW07 9,600bps ON OFF ON 19,200bps OFF ON ON Data length setting (SW08) Set to “OFF” (7 bits). Parity check yes/no setting (SW09) Set to “ON” (yes). Parity (odd/even) setting (SW10) Set to “ON” (even). Stop bit setting (SW11) Set to “ON” (2 bits). Sum check yes/no setting (SW12) Set to “ON” (yes). 2-16 Allocation Areas 2-4 Chapter 2-4 Allocation Areas This chapter describes the types of area to which bits and words can be allocated, and the ranges of these areas for each PC. Bits and Words Allocated to the PC Bits and words can be allocated to Mitsubishi A series PCs as follows. Word Symbol Area Name Bit Numeric Value Character String(*) D Data registers ✓ ✓ ✓ M Internal relays ✓ ✓ ✓ T Timers C Counters L Latching relays ✓ ✓ ✓ B Link relays (hexadecimal input) ✓ ✓ ✓ W Link registers (hexadecimal input) ✓ ✓ ✓ X Input relays (hexadecimal input) ✓ ✓ ✓ Y Output relays (hexadecimal input) ✓ ✓ ✓ R File registers ✓ ✓ ✓ (*) Includes the PT status control area and PT status notify area ✓ : Possible Possible (1 word only) : Not possible F Restrictions on Use The restrictions and cautions that apply specifically when using a PT with a computer link system that uses Mitsubishi A series PCs are presented here. For details on other, general restrictions, refer to the Operation manual for the PT. Screen switching To switch screens by specifying a screen number in the “screen switch setting” of the PT status control area, specify the screen number in BCD (binary coded decimal). Specifying memory table numbers When specifying memory table numbers in the PT status control area, and when specifying memory table numbers by indirect specification, use BCD (binary coded decimal). 2-17 Allocation Areas Chapter 2-4 Setting the PT Clock function When setting the time with the PT’s internal clock function, specify the value in BCD (binary coded decimal). Bit notification When elements for which statuses are notified by bits - such as touch switches, extended I/O inputs, bit memory tables, etc. - are allocated to word devices (D, W, R), since the notification is in word units, all bits other than those used for the notification will be set to “0” (OFF). 2-18 Allocation Areas Chapter 2-4 Mitsubishi A Series PC Allocation Areas Bit Devices (Bit Units) Area PC Input Relays (X) Output Relays (Y) A0J2CPU 0000 to 01DF 0000 to 01DF A0J2HCPU 0000 to 01DF 0000 to 01DF A1SCPU 0000 to 00FF 0000 to 00FF A1SJCPU 0000 to 00FF 0000 to 00FF A2SCPU 0000 to 01FF 0000 to 01FF A2NCPU 0000 to 01FF 0000 to 01FF A2NCPU-S1 0000 to 03FF 0000 to 03FF A3NCPU 0000 to 07FF 0000 to 07FF A3HCPU 0000 to 07FF 0000 to 07FF A3MCPU 0000 to 07FF 0000 to 07FF A2ACPU 0000 to 01FF 0000 to 01FF A2ACPU-S1 0000 to 03FF 0000 to 03FF A3ACPU 0000 to 07FF 0000 to 07FF A2UCPU 0000 to 01FF 0000 to 01FF A2UCPU-S1 0000 to 03FF 0000 to 03FF A2USCPU 0000 to 01FF 0000 to 01FF A2USCPU-S1 0000 to 03FF 0000 to 03FF A3UCPU 0000 to 07FF Notes: 0000 to 07FF Link Relays (B) Internal Relays (M) Latch Relays (L) Special Internal Relays (M) B0000 to B03FF M0000 to M2047 L0000 to L2047 M9000 to M9255 B0000 to B0FFF M0000 to M8191 L0000 to L8191 B0000 to B1FFF S The values indicated in the table above are the ranges that can actually be set with the support tool and used by the PT. S The ranges actually usable differ according to the system configuration. 2-19 Allocation Areas Chapter 2-4 Word Devices Area Data Registers (D) PC Timers (T) Counters (C) Link Registers (W) File Registers (R) Special Data Registers (D) – D9000 to D9127 A0J2CPU A0J2HCPU A1SCPU A1SJCPU A2SCPU D0000 to D1023 A2NCPU T0000 to T0255 C0000 to C0255 W0000 to W03FF R0000 to R4095 A2NCPU-S1 A3NCPU A3HCPU A3MCPU D9000 to D9255 A2ACPU A2ACPU-S1 D0000 to D6143 T0000 to T2047 C0000 to C1023 W0000 to W0FFF A3ACPU A2UCPU R0000 to R8191 A2UCPU-S1 A2USCPU D0000 to D8191 T0000 to T2047 C0000 to C1023 W0000 to W1FFF A2USCPU-S1 A3UCPU Notes: S The values indicated in the table above are the ranges that can actually be set with the support tool and used by the PT. S The ranges actually usable differ according to the system configuration. S The values accessed with timers and counters are the timer and counter present values. 2-20 Specific Error and Their Remedies 2-5 Chapter 2-5 Specific Errors and Their Remedies This chapter describes the specific errors that may occur when using the PT in a computer link system that uses Mitsubishi A series PCs, and the remedies to employ when they occur. Setting Errors If an area that does not exist in the PC is specified when creating a PT screen with the support tool, the screen shown below is displayed during PT operation. Confirm Setting error XXXXX YYYYY XXXXX: YYYYY : Device type Device number If this happens, first check that the area at the PC being used has been secured, then set the correct device. Reception Errors If a reception error occurs during PT operation, the screen shown below is displayed. Receive error <Error details> SCI. parity error SCI. overrun error SCI. framing error Buffer overflow Time out NAK reception error PC No. error Station No. error Sum value error 2-21 Specific Error and Their Remedies Chapter 2-5 The errors that occur specifically with computer link systems that use Mitsubishi A series PCs are described below. For details on errors other than those indicated below, refer to the Operation manual for the PT. Message 2-22 Cause Corrective Action PC Number error S Due to noise, the data has S If the system is used at a site been changed on the transmissubject to a lot of noise, use sion line. cables with protection against noise on the transmission route. Exchange No. error S The station No. at the PC side S Set the station No. at the PC has been changed. side to “0”. S The PC has sent erroneous S Check the operation at the PC data. side. S Due to noise, the data has S If the system is used at a site been changed on the transmissubject to a lot of noise, use sion route. cables with protection against noise on the transmission route. Sum check error S The PC has sent erroneous S Check the operation at the PC data. side. S Due to noise, the data has S If the system is used at a site been changed on the transmissubject to a lot of noise, use sion line. cables with protection against noise on the transmission route. CHAPTER 3 Use With Mitsubishi FX This chapter describes how to make the connections and settings when a PT is connected to a Mitsubishi FX series programmable controller. 3-1 Applicable PTs and PCs 3-1 Chapter 3-1 Applicable PTs and PCs The PT and PC models that can be used with Mitsubishi FX series PCs are indicated here. Usable PT Models The PT models that can be used with the Mitsubishi FX series are tabled below. When using NT30/NT30C, install the system program for Mitsubishi FX in advance using the “NT series system installer”. PT Type Model NT20S NT20S-ST121j-EV3 NT30 (*) NT30-ST131j-E NT30C (*) NT30C-ST141j-E (*) Only an RS-232C connector can be used. Reference: For the versions of the direct connection function that can be used, refer to “1-1 Possible Combinations” (page 1-2). For details on the direct connection function, refer to the Operation manual for the PT model used. Modules mounted at the Connected PC When the connection is to a Mitsubishi FX series PC, the programming console connector of the main base unit is used. The table below lists main base units to which connection is possible. Type FX0-14MR FX0-14MR-D FX0-20MR FX0-20MR-D FX0-30MR FX0-30MR-D FX0-14MT FX0-20MT FX0-14MT-D FX0-20MT-D FX0N FX0N-40MR FX0N-60MR FX0N-40MT FX0N-60MT FX1 FX1-16MR FX1-16MT FX1-24MR FX1-24MT FX1-32MR FX1-32MT FX1-48MR FX1-48MT FX1-64MR FX1-64MT FX1-80MR FX1-80MT FX2 FX2-16MR FX2-128MR FX2-16MS FX2-16MT FX2-128MT FX2-24MR-A1 FX2-24MR-D FX2-48MT-D FX2-32MT-C FX2-24MR FX2-32MR FX2-48MR FX2-64MR FX2-80MR FX2-24MS FX2-24MT FX2-32MS FX2-32MT FX2-48MS FX2-48MT FX2-64MS FX2-64MT FX2-80MS FX2-80MT FX2-48MR-A1 FX2-48MR-D FX2-80MT-D FX2-64MT-C FX2-64MR-A1 FX2-64MR-D FX2-80MR-D FX2C-64MT FX2C-96MT FX2C-128MT FX2C-160MT FX2C 3-2 Mode FX0 FX0-30MT FX0-30MT-D Connection 3-2 Chapter 3-2 Connection The connection is made between the RS-232C connector of the PT to the Mitsubishi FX series PC via an RS-232C/RS-422A convertor unit (type NT-AL001). Make the cables in accordance with the wiring schemes shown in this section, and in accordance with the conditions of use. Parts Required for Connection The connectors, connector covers, crimp terminals, and recommended cables for use with OMRON products are described here. For details on the connectors, connector covers, and crimp terminals used with Mitsubishi products, refer to the manual for the Mitsubishi product. F Parts for RS-232C connector (Common to PT and NT-AL001) Part Connector Connector cover Cable Model Remarks XM2A-0901 9-pin type, made by OMRON DE-9P 9-pin type, made by JAE XM2S-0911 9-pin type, made by OMRON DE-CI-J6 9-pin type, made by JAE AWG28X5P IFVV-SB Multi-core shielded cable, made by Fujikura, Ltd CO-MA-VV-SB 5PX28AWG Multi-core shielded cable, made by Hitachi Cable, Ltd F Recommended Parts for RS-422A Terminal Blocks (For NT-AL001) <Appropriate crimp terminals> Fork type Round type 6.2 mm or less 6.2 mm or less Part Model Crimp terminal (M3) Y1.25-3.5L (*1) 1.25-N3A Remarks Fork type, made by Molex Fork type, made by Japan Solderless Terminal MFG (*1) Appropriate wire size: 0.3 to 0.75 mm2 3-3 Connection Chapter 3-2 Connection Method NT20S Main base unit Mitsubishi FX series PC RS-232C/RS-422A convertor unit (NT-AL001) 9-pin connector RS-232C cable (maximum length: 15 m) 9-pin connector Caution: Note: 25-pin connector RS-422A cable (maximum length: 500 m) After connecting a communication cable, always secure it with the screws. Otherwise the cable may disconnect, causing operation to fail. When connecting to a terminal block, always use crimp terminals. F Wiring Between PT and NT-AL001 PT RS-232C interface NT-AL001 RS-232C connector Abbrev. Pin No. Pin No. FD SD RD RS CS +5V 1 2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9 SG Connector cover (9-pin) SD RD RS CS +5V DR ER SG (9-pin) Shielding wire 3-4 Abbrev. RS-232C interface Connection Chapter 3-2 F Wiring Between NT-AL001 and PC When using FX1, FX2, and FX2C, connect a cable with the wiring scheme shown below directly to the programming console connector of the PC. The programming console connectors of FX0 and FX0N have a different shape; with these types connect a cable with the wiring scheme shown below to an FX-20P-CADP cable made by Mitsubishi, then connect the FX-20P-CADP to the programming console connector of the PC. NT-AL001 RS-422A terminal block RS-422A interface FX series PC Abbrev. Pin No. Pin No. FG SG SDB SDA RDB RDA RSB RSA 1 2 3 4 5 6 7 8 1 2 3 4 RS-422A interface 15 16 17 8-pin terminal block 25-pin Shielding wire Make the connections between SDB and SDA, RDB and RDA, and RSB and RSA, with twisted pair wires. 3-5 Setting 3-3 Chapter 3-3 Setting This chapter describes the settings required at each device in order to use the programming console connector of a Mitsubishi FX series PC. Settings at the PT Make the following settings in the PT’s maintenance mode by using the memory switches. When using NT30/NT30C, install the system program for Mitsubishi FX in advance using the “NT series system installer”. Reference: Set the other memory switches in accordance with the conditions of use. F When using NT20S Item Setting Comm. Type With FX0 With FX0N With FX1 With FX2, FX2C :MELSEC-FX0 :MELSEC-FX0N :MELSEC-FX1 :MELSEC-FX2 F When using NT30/NT30C 3-6 Item Setting Port select RS-232C Comm. Type With FX0 With FX0N With FX1 With FX2, FX2C :MELSEC-FX0 :MELSEC-FX0N :MELSEC-FX1 :MELSEC-FX2 Setting Chapter 3-3 Settings at the NT-AL001 When using the RS-232C/RS-422 convertor unit (NT-AL001), set the RS-422A communication conditions with the DIP switches as shown in the figure below. (Factory setting) [SW1-1] Not used (always ON) [SW1-2] ON Setting for built-in terminal resistor Terminal resistor used [SW1-3, 4] Selection of 2-wire type/4-wire type SW1-3 SW1-4 OFF 4-wire type ON [SW1-5, 6] Selection of RS-422A transmission mode SW1-5 SW1-6 OFF Transmission at any time ON PC Settings No particular settings have to be made at the PC in order to use the PT with a programming console connector. 3-7 Allocation Areas 3-4 Chapter 3-4 Allocation Areas This chapter describes the types of area to which bits and words can be allocated, and the ranges of these areas for each PC. Bits and Words Allocated to the PC Bits and words can be allocated to Mitsubishi FX series PCs as follows. Word Symbol Area Name Bit Numeric Value Character String(*) D Data registers ✓ ✓ M Internal relays ✓ ✓ ✓ T Timers C Counters S State relays ✓ ✓ ✓ X Input relays ✓ ✓ ✓ Y Output relays ✓ ✓ ✓ (*) Includes the PT status control area and PT status notify area ✓ : Possible : Possible (1 word only) : For C0 to C199, 1 word possible; for C200 and higher, 2 words possible : Not possible Reference: Allocations cannot be made to the special use areas for data registers (D) and auxiliary registers (M). F Restrictions on Use The restrictions and cautions that apply specifically when using a PT with the programming console connector of a Mitsubishi FX series PC are presented here. For details on other, general restrictions, refer to the Operation manual for the PT. Screen switching To switch screens by specifying a screen number in the “screen switch setting” of the PT status control area, specify the screen number in BCD (binary coded decimal). Specifying memory table numbers When specifying memory table numbers in the PT status control area, and when specifying memory table numbers by indirect specification, use BCD (binary coded decimal). Setting the PT Clock function When setting the time with the PT’s internal clock function, specify the value in BCD (binary coded decimal). 3-8 Allocation Areas Chapter 3-4 Bit notification When elements for which statuses are notified by bits - such as touch switches, extended I/O inputs, bit memory tables, etc. since the notification is in word units, all bits other than those used for the notification will be set to “0” (OFF). Bit and Word Allocations to Bit Devices (M, S, X, Y) The allocation of bits and words to bit devices (M, S, X, Y) is described here. For details on the ranges of the areas within which specification is possible, refer to “Mitsubishi FX Series PC Allocation Areas” (page 3-11). F Bit Allocations When allocating bits to bit devices, any number not outside the range for the area can be specified. However, since host link access is in word (16 bit) units, the following points must be observed when allocating bits. S Points to note when allocating to M (special relays) and S (state relays) M and S devices are bit devices expressed in decimal in the case of Mitsubishi FX series PCs. However, in the host link, data is written in word (16-bit) units. Therefore, when data is written, all other bits in the same word are cleared to “0” (“other bits in the same word” here means bits which have the same quotient when divided by 16). S Points to note when allocating to X (input relays) and Y (output relays) X and Y devices are bit devices expressed in octal in the case of Mitsubishi FX series PCs. However, host link writing is in word (16-bit) units. Therefore, when data is written, all other bits in the same word are cleared to “0” (since one word is 16 bits, each of the following sequences of bits (least significant two digits) is contained within one word: 00 to 17, 20 to 37, 40 to 57, and 60 to 77). 3-9 Allocation Areas Chapter 3-4 F Word Allocations When allocating bits to bit devices, the following points relating to the method of specification must be observed. S Points to note when allocating to M (special relays) and S (state relays) M and S devices are bit devices expressed in decimal in the case of Mitsubishi FX series PCs. However, inside the PC, the bits are actually managed in units of 16. Therefore, when accessing words using word allocation, make the specification so that the first bit number is a multiple of 16. S Points to note when allocating to X (input relays) and Y (output relays) X and Y devices are bit devices expressed in octal in the case of Mitsubishi FX series PCs. Therefore, when accessing words using word allocation, ensure that the least significant two digits of the first bit number are “00”, “20”, “40”, or “60”. The area used for word allocation is as follows. Number of allocated words 15 14 2 1 First word First + 15 bits First + 14 bits First + 2 bits First + 1 bit First + 0 bits First + 1 word First + 31 bits First + 30 bits First + 18 bits First + 17 bits First + 16 bits 1 word 0 Bit Word Allocations to Word Devices (D, T, C) Word allocations to word devices (D, T, C) are described here. It is impossible to make bit allocations to word devices. Normally one word device occupies one word (16 bits). Therefore, when allocating a word to a word device, any number not outside the range for the area can be specified. However, in the case of counters C200 and higher, one word device is 32 bits, i.e., it occupies 2 words. For details on the ranges of the areas within which specification is possible, refer to “Mitsubishi FX Series PC Allocation Areas” (page 3-11). The area used for word specification is as follows. S Normal device 15 Number of allocated words 3-10 14 13 12 11 10 9 8 7 6 5 First word First word device (lower 16 bits) First + 1 word First word device (upper 16 bits) 4 3 2 1 0 Bit Allocation Areas Chapter 3-4 S 32-bit devices from C200 onward 15 Number of allocated words 14 13 12 First word 11 10 9 8 7 6 5 4 3 2 1 0 Bit First word device First + 1 word device First + 1 word Mitsubishi FX Series PC Allocation Areas Type Unit Data Registers (D) Auxiliary Relays (M) Timers (T) Counters (C) State Relays (S) Input Relays (X) Output Relays (Y) FX0 Bit ––– M0 to M511 ––– ––– S0 to S63 X0 to X177 X0 to X177 FX0N Word D0 to D31 M0 to M496 T0 to T55 C0 to C254 S0 to S48 X0 to X17 Y0 to Y17 FX1 Bit ––– M0 to M1023 ––– ––– S0 to S999 X0 to X177 X0 to X177 Word D0 to D127 M0 to M1008 T0 to T245 C0 to C254 S0 to S984 X0 to X17 Y0 to Y17 Bit ––– M0 to M1023 ––– ––– S0 to S999 X0 to X177 X0 to X177 Word D0 to D511 M0 to M1008 T0 to T255 C0 to C255 S0 to S984 X0 to X17 Y0 to Y17 FX2 FX2C Notes: S The values indicated in the table above are the ranges that can actually be set with the support tool and used by the PT. S The ranges actually usable differ according to the system configuration. 3-11 + APPENDIX This chapter describes the specifications of the connectors of OMRON products used for communications. APP-1 OMRON Product Connector Specifications Appendix A APPENDIX A OMRON Product Connector Specifications PT Connectors F RS-232C connector specifications S Connector type : RS-232C connector (9-pin) S Electrical characteristics : Conform to EIA RS-232C S Connection signals Connector Pin No. Signal Name Abbreviation Signal Direction PT ↔ External Device – – 1 Not used 2 Send data SD (TXD) 3 Receive data RD (RXD) 4 Request to send RS (RTS) 5 Clear to send CS (CTS) 6 +5V for convertor (max. 150 mA) +5V 9 Signal ground SG – F RS-422A terminal block specifications (NT30/NT30C only) S Connected terminal block : RS-422A terminal block (M3.5 screw) S Electrical characteristics : Conform to EIA RS-422A S Connection signals Signal Name Send data (–) APP-2 Abbreviation SDA Send data (+) SDB Receive data (–) RDA Receive data (+) RDB Signal Direction PT ↔ External Device OMRON Product Connector Specifications Appendix A RS-232C/RS-422 Convertor Unit (NT-AL001) F RS-232C connector specifications S Connector type : RS-232C connector (9-pin) S Electrical characteristics : Conform to EIA RS-232C S Connection signals Connector Pin No. Connector cover Signal Name Grounding or earth for safety purposes Abbreviation Signal Direction PT ↔ External Device FG – – 1 Not used – 2 Send data SD (TXD) 3 Receive data RD (RXD) 4 Receive dataRequest to send (shorted to CS internally) RS (RTS) 5 Clear to send (shorted to RS internally) CS (CTS) 6 +5V for convertor (150 mA) 7 Data set ready (shorted to ER internally) * DR (DSR) –* 8 Data terminal ready (shorted to DR internally) * ER (DTR) –* 9 Signal ground SG (GND) – +5V - The connector cover is connected to the functional ground terminal (pin No.1) of the RS-422A terminal block. * Pins No.7 and No.8 are connected internally to each other and do not have the function as the control lines. F RS-422A terminal block specifications S Connected terminal block : RS-422A terminal block (M3 screw) S Electrical characteristics : Conform to EIA RS-422A S Connection signals Connector Pin No. Signal Name Abbreviation Signal Direction PT ↔ External Device FG – SG (GND) – 1 Functional ground 2 Signal ground 3 Send data (+) 4 Send data (–) SDA 5 Receive data (+) RDB 6 Receive data (–) RDA 7 Request to send (+) CSB 8 Request to send (–) CSA Note: SDB The CSB and CSA signals are for special applications. APP-3 INDEX B Mitsubishi A Series PC Allocation Areas . . . . . 2-19 Bit Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Mitsubishi FX Series PC Allocation Areas . . . . 3-11 Bit and Word Allocations to Bit Devices (M, S, X, Y) (for Mitsubishi FX) . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Modules Mounted at the Connected PC for Mitsubishi A computer links . . . . . . . 2-3 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-2 Bit notification for Mitsubishi A computer links . . . . . . 2-18 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-9 P Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 Bits and Words Allocated to the PC for Mitsubishi A computer links . . . . . . 2-17 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-8 C Clock function for Mitsubishi A computer links . . . . . . 2-18 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-8 Computer link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Computer Link Module Settings <A0J2-C214S1> . . . . . . . . . . . . . . . . . . . <A1SJ71UC24-R2, A1SJ71C24-R2> (RS-232C dedicated) . . . . . . . . . . . . . . . <A1SJ71UC24-R4, A1SJ71C24-R4> (RS-422 dedicated) . . . . . . . . . . . . . . . . <AJ71C24-S8> . . . . . . . . . . . . . . . . . . . . <AJ71UC24> . . . . . . . . . . . . . . . . . . . . . 2-12 2-15 2-16 2-13 2-14 Connection Method (for Mitsubishi FX) . . . . . . . 3-4 Parts for RS-232C (Common to PT and NT-AL001) for Mitsubishi A Computer links . . . . . . . 2-4 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-3 Parts Required for Connection for Mitsubishi A computer links . . . . . . . 2-4 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-3 PC Settings for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-7 PC that can be connected . . . . . . . . . . . . . . . . . . 1-2 Possible Combinations . . . . . . . . . . . . . . . . . . . . . 1-2 R Recommended Parts for RS-422A Terminal Block (for NT30/NT30C) for Mitsubishi A Computer links . . . . . . . 2-4 Recommended Parts for RS-422A Terminal Blocks (for NT-AL001) for Mitsubishi A computer links . . . . . . . 2-5 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-3 Direct connection version . . . . . . . . . . . . . . . . . . . 1-2 RS-232C connector specifications OMRON PT . . . . . . . . . . . . . . . . . . . . APP-2 NT-AL001 . . . . . . . . . . . . . . . . . . . . . . APP-3 M RS-232C/RS-422 Convertor Unit (NT-AL001) . . . . . . . . . . . . . . . . . . . . . . . . . . . . APP-3 D Methods for connection (for Mitsubishi A computer links) RS-232C (PT)-RS-232C (Computer Link) . . . . . . . . . . . . . . . . . . . . RS-232C (PT)-RS-422A (Computer Link) . . . . . . . . . . . . . . . . . . . . RS-422A (PT)-RS-232C (Computer Link) . . . . . . . . . . . . . . . . . . . . RS-422A (PT)-RS-422A (Computer Link) . . . . . . . . . . . . . . . . . . . . RS-422A terminal block specifications NT30/NT30C only . . . . . . . . . . . . . . . APP-2 NT-AL001 . . . . . . . . . . . . . . . . . . . . . . APP-3 2-5 S 2-6 2-8 2-7 Screen switching for Mitsubishi A computer links . . . . . . 2-17 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-8 Setting for Mitsubishi A computer links . . . . . . 2-10 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-6 Setting for NT-AL001 for Mitsubishi A computer links . . . . . . 2-11 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-7 Specifying memory table numbers for Mitsubishi A computer links . . . . . . 2-17 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-8 System installer . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 U Usable PT Models for Mitsubishi A computer links . . . . . . . 2-2 for Mitsubishi FX . . . . . . . . . . . . . . . . . . . 3-2 W Word Allocations . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 Word Allocations to Word Devices (D, T, C) (for Mitsubishi FX) . . . . . . . . . . . . . . . . . . . . . . . . 3-10 Words . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. V042-E1-1 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code 1 Date April Revised content 1997 Original production ">
/
Download
Bare en venlig påmindelse. Du kan se dokumentet lige her. Men vigtigst af alt har vores AI allerede læst det. Den kan forklare komplekse ting i enkle vendinger, besvare dine spørgsmål på ethvert sprog og hjælpe dig med hurtigt at navigere selv de længste eller mest komplicerede dokumenter.
Annonce