Mitsubishi GT15 J71E71-100 Ethernet communication unit User's Manual
Below you will find brief information for Ethernet communication unit GT15 J71E71-100. The GT15 J71E71-100 is an ethernet communication unit required for connecting a GOT (Graphic Operator Terminal) to an ethernet network. This enables communication between the GOT and a PLC (Programmable Logic Controller) using ethernet protocols.
Advertisement
Advertisement
GT15 Ethernet communication unit
User's Manual
GT15-J71E71-100
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.
MODEL
MODEL
CODE
GT15-J71E71-100-U
1D7M29
IB(NA)-0800314-C(0507)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
DANGER
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the CAUTION level may lead to a serious accident according to the circumstances.
Always follow the precautions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
[DESIGN PRECAUTIONS]
DANGER z Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100 mm
(3.94 inch) otherwise malfunctions may occur due to noise.
[INSTALLATION PRECAUTIONS]
DANGER z Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the
GOT.
Not doing so can cause a unit failure or malfunction.
z Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.
CAUTION z Use this unit in the environment given in the general specifications of the GT15 User's Manual.Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
z When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to screw or unit damage.
[WIRING PRECAUTIONS]
DANGER z Be sure to shut off all phases of the external power supply used by the system before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
CAUTION z Use crimp-contact, pressure-displacement or soldering to wire the connectors for external connections properly using the manufacturer-specified tools.
If the connection is incomplete, it may cause the module to short circuit, catch fire, or malfunction.
z Connect the connectors to the unit securely.
z Always secure the cables connected to the unit, e.g. run them in conduits or clamp them.
Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.
[STARTUP AND MAINTENANCE PRECAUTIONS]
DANGER z Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction.
CAUTION z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this unit directly.
Doing so can cause a unit malfunction or failure.
z Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
z Do not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
[DISPOSAL PRECAUTIONS]
CAUTION z Dispose of this product as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION z Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Manuals
The following shows manuals relevant to this product.
Detailed Manual
Manual name
GT15 User's Manual
(Option)
GOT1000 Series Connection Manual
(Option)
Manual Number
(Type code)
SH-080528ENG
(1D7M23)
SH-080532ENG
(1D7M26)
Relevant Manuals
For relevant manuals, refer to the PDF manual stored within the drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives, refer to Chapter 4, "EMC Directives and Low Voltage
Directives" of the manual (GT15 General Description) included with the GOT used.
The CE logo is printed on the rating plate of the GOT, indicating compliance with the EMC and low voltage directives.
By making this product conform to the EMC directive and low voltage instruction,it is not necessary to make those steps individually.
1. Overview
This User's Manual describes the GT15 Ethernet communication unit.
The GT15-J71E71-100 is required when performing Ethernet connection or Gateway function with GOT.
After unpacking the box of GT15-J71E71-100, please check if the following items are contained.
Product name
Ethernet communication unit
Mounting screw set (2 pieces of screw,2 pieces of label)
Model name
GT15-J71E71-100
-
Quantity
1
1
For information concerning necessary OS in case of using GT15-
J71E71-100,refer to GOT 1000 Series Connection Manual.
2. Specifications
2.1 Performance Specifications
The performance specifications of the Ethernet communication unit are indicated below.
Refer to the used GT15 User's Manual for the general specifications of the Ethernet communication unit.
Item Specification
Data transfer method 10BASE-T 100BASE-TX
Transmission method
Transmission specifications
Maximum node to mode distance
Maximum segment length
Base band
200m
100m
Base band
200m
100m
Maximum number of cascade connection
4 steps
Number of units mounted to GOT
2 steps
Only 1 unit can be mounted to the extension unit interface.
Number of GOTs connected
128 (Recommend 16 or less)*1*2
Connecting condition
GOT placing distance
100m*1
Internal current consumption(DC5V) 0.22A
Weight 0.09kg
*1 This depends on the specifications of the Ethernet network system to which the GOT is connected.
For the details, refer to the manual of Ethernet module of connected PLC.
*2 If multiple network equipments (including GOT) are connected within a segment, the network load would increase.
In such condition, the communication performance between GOT and PLC may be declined.
The decline of the communication performance may be improved by the following measures.
• Using switching hubs.
• Reducing the number of monitoring devices of the GOT.
2.2 Specifications of the related devices
Use the connection cable and the hub which meet the
IEEE802.3 10BASE-T/100BASE-TX standard.
Item
Cable
Specifications
10BASE-T 100BASE-TX
Non-shielded twisted pair wire (UTP cable)
(category3(4, 5))
Shielded twisted pair wire
(STP cable)
(category5)
Connector RJ45jack
Hub 10Mbps hub
RJ45jack
100Mbps hub
3. Name of the Parts
5) 6)
1)
3)
7)
2)
4)
No.
1)
2) Interface connector
3) Extension connector
4)
5)
6)
7)
Name
Mounting screw
Ethernet connector
100M LED
SD/RD LED
Rating plate
Description
Mounting screws fixed with the front communication unit or GOT.
Connector connected to the front communication unit or GOT.
Connector with which the back communication unit is fixed.
Connector to which Ethernet cable is connected.
It lights up during 100 Mbps transmission.
It blinks during data sending/ receiving.
-
4. Installation Procedure
(1) Power off the GOT.
(2) Remove the one extension unit covers of the GOT.
(3) Fit the Ethernet communication unit along the groove of the GOT case.
(4) Fasten the Ethernet communication unit by tightening its mounting screws (2 places) with tightening torque
0.36 to 0.48 N•m.
(5) When mounting an Ethernet communication unit on the outer layer, remove the connector cover and the seal.
When not mounting any communication unit on the outer layer, stick accessory labels on the top of mounting screws (2 places) to cover the top of them in order to avoid receiving electrostatic.
Keep the connector cover fixed.
Keep the seal stuck as it is.
Accessory labels
Connector cover
Seal
Point
(1) Grounding work for the 10BASE-T and 100BASE-TX requires appropriate safety measures.
Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables.
(2) If you remove the Ethernet unit, detach it from specified direction (shown PULL) so as not to break a connector.
5. External Dimensions
63 (2.48) GOT main unit
3 (0.12)
0.5
(0.02)
2.5
(0.10)
X
21
(0.83)
Dimensions of X when mounted to the GOT.
8.4”
10.4”, 12.1”, 15”
23 (0.91)
21 (0.83)
Unit: mm (inch)
Ethernet is a registered trademark of Xerox Corporation, U.S.
Other business or product names mentioned herein are a trademark or registered trademark of each company.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control.
However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
U.S.A
Brazil
Germany
U.K
Italy
Spain
France
South Africa
Hong Kong
China
Taiwan
Korea
Singapore
Thailand
Indonesia
India
Australia
Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Tel : +1-847-478-2100
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
Mitsubishi Electric Europe B.V. French Branch
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China
Tel : +86-21-6120-0808
Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel : +65-6473-2308
F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3
Road, Bangkpongpang, Yannawa, Bangkok 10120
Tel : +66-2-682-6522
P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan
Industri/Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,
PUNE-411026, India
Tel : +91-20-712-2807
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.
Download
Advertisement
Key features
Ethernet communication
GOT1000 series compatibility
Remote monitoring
Data logging
Data exchange
Frequently asked questions
The maximum distance is 100m for both 10BASE-T and 100BASE-TX communication.
Only 1 unit can be mounted to the extension unit interface.
The unit supports both 10BASE-T and 100BASE-TX communication.