Mitsubishi GOT1000 GT15-J71E71-100 Ethernet communication unit User's Manual
تبلیغات
تبلیغات
GT15 Ethernet communication unit
User's Manual
GT15-J71E71-100
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.
MODEL
MODEL
CODE
GT15-J71E71-100-U
1D7M29
IB(NA)-0800314-I(1202)MEE
lSAFETY PRECAUTIONSl
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
DANGER
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the CAUTION level may lead to a serious accident according to the circumstances.
Always follow the precautions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
[DESIGN PRECAUTIONS]
DANGER
Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100mm
(3.94 inches) otherwise malfunctions may occur due to noise.
[INSTALLATION PRECAUTIONS]
DANGER
Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the
GOT.
Not doing so can cause a unit failure or malfunction.
Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.
CAUTION
Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used.
Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to screw or unit damage.
[WIRING PRECAUTIONS]
DANGER
Be sure to shut off all phases of the external power supply used by the system before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
CAUTION
Use crimp-contact, pressure-displacement or soldering to wire the connectors for external connections properly using the manufacturer-specified tools.
If the connection is incomplete, it may cause the module to short circuit, catch fire, or malfunction.
Connect the connectors to the unit securely.
Always secure the cables connected to the unit, e.g. run them in conduits or clamp them.
Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.
[STARTUP AND MAINTENANCE PRECAUTIONS]
DANGER
Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction.
CAUTION
Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
Do not touch the conductive areas and electronic parts of this unit directly.
Doing so can cause a unit malfunction or failure.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
Do not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.
Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
[DISPOSAL PRECAUTIONS]
CAUTION
Dispose of this product as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION
Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User's Manual for the GOT used, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Manuals
The following shows manuals relevant to this product.
Detailed Manual
Manual name
GT15 User's Manual
(Sold separately)
GOT1000 Series Connection Manual
(Mitsubishi Products) for GT Works3
(Sold separately)
Manual number
(Model code)
SH-080528ENG
(1D7M23)
SH-080868ENG
(1D7MC2)
Relevant Manuals
For relevant manuals, refer to the PDF manuals stored in the CD-
ROM for the drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
To configure a system meeting the requirements of the EMC and
Low Voltage Directives when incorporating the Mitsubishi GOT
(EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the General Description included with the GOT used.
The CE mark, indicating compliance with the EMC and Low
Voltage Directives, is printed on the rating plate of the GOT.
Compliance with the Radio Waves Act (South
Korea)
This product complies with the Radio Waves Act (South Korea).
Note the following when using the product in South Korea.
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이 점을
주의하시기 바라며 , 가정외의 지역에서 사용하는 것을 목적으 로 합니다 .
(The product is for business use (Class A) and meets the electromagnetic compatibility requirements.
The seller and the user must note the above point, and use the product in a place except for home.)
Packing List
The following items are included.
Model
GT15-J71E71-
100
Product
Ethernet communication unit
Mounting screw set (2 screws, 2 stickers)
Quantity
1
1
1. OVERVIEW
This User's Manual describes the GT15 Ethernet communication unit(hereinafter referred to as the Ethernet communication unit).
The GT15-J71E71-100 is required for the operations such as the
Ethernet connection or Gateway function with GOT.
For attachable GOTs, the User's Manual for the GOT used.
When using the Ethernet connection, make the communication settings to perform communication between the GOT and PLC.
Refer to GOT1000 Series Connection Manual for details of Ethernet connection.
For information concerning necessary OS in case of using GT15-
J71E71-100,refer to GOT 1000 Series Connection Manual.
2. SPECIFICATIONS
2.1 Performance Specifications
The performance specifications of the Ethernet communication unit are indicated below.
The general specifications of the Ethernet communication unit are the same as those of the GOT.
Refer to the User's Manual for the GOT used for the general specifications of the GOT.
Transmission specifications
Item Specification
Data transfer method 10BASE-T 100BASE-TX
Transmission method
Maximum node to mode distance
Maximum segment length
Base band
200m
100m
Base band
200m
100m
Maximum number of cascade connection*1
4 steps 2 steps
Number of units mounted to GOT
Connecting condition
Number of GOTs connected
GOT placing distance
Only 1 unit can be mounted to the extension unit interface.
128 (Recommend 16 or less)*2*3
100m*2
Internal current consumption (5VDC) 0.224A
Weight 0.09kg (0.20lb)
*1 Maximum number of connectable nodes when a repeater hub is used
For the details, refer to the manual of Ethernet module of connected PLC.
*2 This depends on the specifications of the Ethernet network system to which the GOT is connected.
For the details, refer to the manual of Ethernet module of connected PLC.
*3 If multiple network equipments (including GOT) are connected within a segment, the network load would increase.
In such condition, the communication performance between GOT and PLC may be declined.
The decline of the communication performance may be improved by the following measures.
• Using switching hubs.
• Reducing the number of monitoring devices of the GOT.
2.2 Specifications of the related devices
Use the connection cable and the hub which meet the IEEE802.3
10BASE-T/100BASE-TX standard.
Item
Cable
10BASE-T
Non-shielded twisted pair wire (UTP cable)
(category3(4, 5))
Connector RJ45jack
Hub 10Mbps hub
Specifications
100BASE-TX
Shielded twisted pair wire
(STP cable)
(category5)
RJ45jack
100Mbps hub
See the "List of valid devices applicable for GOT1000 series" (GOT-
A-0010) for information about models whose operations have been confirmed.
For technical documents, please contact your local Mitsubishi representative.
When using any model not mentioned in the "List of valid devices applicable for GOT1000 series", the model may not work normally.
The Technical News above is available as a reference at the information site for Mitsubishi industrial automation products.
(MELFANSweb website: http://wwwf2.mitsubishielectric.co.jp/ english/index.html)
3. PART NAMES AND EXTERNAL
DIMENSIONS
63 (2.48) GOT main unit
3 (0.12)
3)
2.5
(0.10)
5) 6)
1)
7)
X
2)
No.
Name
1) Mounting screw
5) 100M LED
6) SD/RD LED
7) Rating plate
21
4) (0.83)
Dimensions of X when the Ethernet communication unit is mounted to the GOT.
15”, 10.4” 21 (0.83)
12.1” 18 (0.71)
8.4”, 5.7” 23 (0.91)
2) Interface connector
3) Extension connector
4) Ethernet connector unit: mm (inch)
Description
Mounting screws fixed with a front extension unit or GOT
Extension connector installed to a front extension unit or the GOT
Extension connector to which a back extension unit is installed
Connector to which Ethernet cable is connected
It lights up during 100 Mbps transmission.
It blinks during data sending/receiving.
-
4. INSTALLATION PROCEDURE
The installation procedure for the Ethernet communication unit is explained using the GT1575.
(1) Power off the GOT.
(2) Remove one extension unit cover of the GOT.
(3) Fit the Ethernet communication unit in the GOT case.
(4) Fasten the Ethernet communication unit by tightening its mounting screws (2 places) with tightening torque 0.36 to 0.48
N•m.
(5) When installing an extension unit on the unit that has been installed, remove the connector cover and the sticker.
When not installing an extension unit on the unit that has been installed, in order to avoid receiving electrostatic, stick accessory stickers to cover the top of mounting screws (2 places).
Keep the connector cover fixed.
Keep the sticker stuck as it is.
Accessory stickers
Connector cover
Sticker
Point
(1) Grounding work for the 10BASE-T and 100BASE-TX requires appropriate safety measures.
Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables.
(2) If you remove the Ethernet unit, detach it from specified direction (shown PULL) so as not to break a connector.
Ethernet is a registered trademark of Xerox Corporation, U.S.
Other business or product names mentioned herein are a trademark or registered trademark of each company.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control.
However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc.
Brazil
500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A.
Tel : +1-847-478-2100
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Germany
U.K
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K.
Tel : +44-1707-276100
Italy
Spain
France
South Africa
Hong Kong
Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy
Tel : +39-039-60531
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80,
E-08190 Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France
Tel : +33-1-5568-5568
Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando, South Africa
Tel : +27-11-928-2000
Mitsubishi Electric Automation (Hong Kong) Ltd.
10th Floor, Manulife Tower, 169 Electric
China
Taiwan
Road, North Point, Hong Kong
Tel : +852-2887-8870
Mitsubishi Electric Automation (China) Ltd.
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
Shanghai 200003, China
Tel : +86-21-6120-0808
Setsuyo Enterprise Co., Ltd.
6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang,
Taipei
Tel : +886-2-2299-2499
Korea Mitsubishi Electric Automation Korea Co., Ltd.
1480-6, Gayang-dong, Gangseo-ku Seoul
157-200,
Tel : +82-2-3660-9552
Singapore Mitsubishi Electric Asia Pte, Ltd.
307
Mitsubishi Electric Building, Singapore 159943
Tel : +65-6470-2460
Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd.
Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd,
T.Kannayao,
Tel : +66-2-517-1326
Indonesia P.T. Autoteknindo Sumber Makmur
Muara Karang Selatan, Block A/Utara
No.1 Kav. No.11 Kawasan Industri Pergudangan
Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia
India
Tel : +62-21-6630833
Messung Systems Pvt, Ltd.
Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari,
India
Australia
Tel : +91-20-2712-3130
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan, February 2012.
دانلود