SmartPro 120V 750VA 600W Line-Interactive Sine Rack/Tower, USB, RB9 Serial


Add to my manuals
5 Pages

advertisement

SmartPro 120V 750VA 600W Line-Interactive Sine Rack/Tower, USB, RB9 Serial | Manualzz

SmartPro 120V 750VA 600W Line-Interactive Sine

Wave UPS, Extended Run, SNMP, Webcard, 2U

Rack/Tower, USB, RB9 Serial

MODEL NUMBER: SMART750RMXL2U

Highlights

.75kVA / 750VA / 600W line interactive 2U rack/tower UPS,

Sine wave output

120V output, Corrects brownouts and overvoltages from 83V to

147V

0.8 Power Factor, Interactive

LCD interface

Extended runtime options up to

450W

4 post compatible mounting accessories

95% line-mode efficiency, 2 switched load banks

USB, RS232, EPO and slot for

SNMPWEBCARD option

120V NEMA 5-15P input, 6

NEMA 5-15R outlets

Description

Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for

Applications

Distributed Server Rooms critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels

Network Closets

Small Business Networks while maintaining a full battery charge in case of power failure. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options.

Voice over IP (VoIP) Phone

Systems

Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 95% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and optional

SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in power

Package Includes

SMART750RMXL2U UPS

System management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert

PowerAlert software with USB,

Serial & EPO cabling monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily

4 post installation kit

Owner's manual rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.

Features

Tripp Lite SMART750RMXL2U line interactive 2U rack/tower UPS with 750VA / .75kVA / 600W capacity and extended runtime options

Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 147V

NEMA 5-15P input plug; 6 NEMA 5-15R output receptacles, Two independently switched output load banks

Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages

High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions

Internal batteries offer 20.7minutes at 50% load (300W) and 8.5 minutes at 100% load (600W)

Extended runtime is available with optional BP24V15RT2U (limit 1), BP24V28-2U (limit 1), BP24V70-3U (multi-pack compatible) and BP24V36-2US

1 / 5

(multi-pack compatible); Output is reduced to 450 watts maximum with external battery packs

External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment

Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information

LCD interface also supports a number of advanced user setup and operating preferences

Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement

Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X

Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable

Specifications

OUTPUT

Output Capacity Details

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Nominal Output Voltage(s)

Supported

Frequency Compatibility

Output Voltage Regulation (Line

Mode)

Output derates to 450 watts in all external battery pack configurations

750

.75

600

.6

0.8

120V

60 Hz

-21%, +8%

Output Voltage Regulation (Battery

Mode)

Output Receptacles

Load Management Receptacles

+/- 5%

(6) 5-15R

Two switchable two-outlet 5-15R load banks

Output AC Waveform (AC Mode) Sine wave

Output AC Waveform (Battery Mode) Pure Sine wave

INPUT

Rated input current (Maximum Load) 7.5A

Nominal Input Voltage(s) Supported 120V AC

UPS Input Connection Type 5-15P

Input Circuit Breakers

UPS Input Cord Length (ft.)

10A

10

2 / 5

UPS Input Cord Length (m)

Recommended Electrical Service

Input Phase

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

3.05

15A 120V

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Internal UPS Replacement Battery

Cartridge

Battery Access

Battery Replacement Description

8.5 min. (600w)

20.7 min. (300w)

Extended runtime supported via optional external battery packs

BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible); BP24V36-2US (multi-pack compatible)

24

Less than 4.5 hours from 10% to 90% (typical, full load discharge)

See Tripp Lite UPS Replacement battery selector

Front panel battery access door

Hot-swappable, user replaceable batteries

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147

Input voltages between 128 and 147 are reduced by 12%

Input voltages between 83 and 107 are boosted by 14%

LEDS ALARMS & SWITCHES

LED Indicators

Audible Alarm

Alarm Cancel Operation

Switches

Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available

3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

EMI / RFI AC Noise Suppression

570 joules

Yes

PHYSICAL

Included Mounting Accessory

Description

4 post rackmount installation accessories included

3 / 5

Installation Form Factors Supported with Optional Accessories

Primary Form Factor

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)

Rackmount

3.45 x 17.35 x 13.15

8.8 x 44.1 x 33.4

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

2

35.4

UPS Power Module Weight (kg) 16.1

UPS Shipping Dimensions (hwd / in.) 7.9 x 22.85 x 19.3

UPS Shipping Dimensions (hwd / cm)

20.1 x 58 x 49

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

UPS Housing Material

46.4

21.1

Fan

Steel

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

AC Mode BTU / Hr. (Full Load)

AC Mode Efficiency Rating (100%

Load)

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

0 to 95%, non-condensing

109

95%

COMMUNICATIONS

Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

Communications Cable

WatchDog Compatibility

Included

USB and DB9 cabling included

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

4 milliseconds (AC to battery mode), 2 milliseconds (Battery to AC mode)

83

147

4 / 5

SPECIAL FEATURES

Grounding Lug

Cold Start (Startup in Battery Mode

During a Power Failure)

High Availability UPS Features

Green Energy-Saving Features

Back panel grounding lug

Cold-start operation supported

Hot swappable batteries

Individually controllable load banks

CERTIFICATIONS

UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)

WARRANTY

Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.

Connected Equipment Insurance

(U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

5 / 5

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals