QuickSpecs HP ProLiant DL560 Overview 1. Dual 550W Hot Plug Redundant Power 2. 2U (3.5" Height) rack form factor 3. PCI-X Riser Cage, Three 64-bit PCI-X slots 4. Six memory DIMM slots 5. Tool-less "Snap in" Rail Solution 6. Hood 7. LEDs 8. Slimline Removable media Bay with 24x CD-ROM installed 9. Hood latch (accesses processors and fans) 10. 1.44 MB Diskette Drive 11. Wide Ultra3 SCSI drive cage for two hot plug hard drives or one DAT hot plug tape drive (plus 1 hard drive) 12. Hot Plug Fans 13. DC Power Converter Module What's New Intel® Xeon® Processors MP at 3.0 GHz/4MB, 2.7 GHz/2MB, or 2.2 GHz/2MB (Expandable to 4 processors) DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 1 QuickSpecs HP ProLiant DL560 Overview At a Glance Intel Xeon Processors MP at 3.0 GHz/4MB, 2.7 GHz/2MB, 2.2 GHz/2MB, 2.8 GHz/2MB, 2.5 GHz/1MB, 2.0 GHz/1MB (Expandable to 4 processors) The HP ProLiant DL560 delivers extraordinary performance and maximum power efficiency in an ultra dense, rack optimized form factor ServerWorks Grand Champion-LE chipset 2x1 interleaved memory, 200MHz DDR SDRAM Memory (PC2100 Registered SDRAM with Advanced ECC functionality) 1024 MB or 512 MB (depending on model) standard memory, expandable to 12 GB HP Advanced Memory Protection Two, full length 64-bit/100 MHz Non-Hot Pluggable PCI slots, one full length 64-bit/133 MHz Non-Hot Pluggable Integrated Lights-Out Standard Management (iLO) on system board Two NC7781 PCI-X Gigabit NICs (embedded) Integrated Smart Array 5i Plus Controller (Ultra3) with 64-MB total memory on 5i Plus Memory Module Battery-Backed Write Cache Enabler module on all 2P models (optional on 1P model) Internal Hot Plug Drive Storage of up to 600 GB (2 x 300 GB 1" Ultra320 hard drives) Redundant Cooling Zones for major subsystems (Memory, I/O, CPUs) assure 7x24 cooling Toolless and virtually cable-less internal design Rapid Deployment racking solution (rack rails and cable management) Protected by HP Services and a worldwide network of resellers and service providers. Three-year Next Business Day, on-site limited global warranty. Certain restrictions and exclusions apply. Pre-Failure Notification on processors, memory, and SCSI hard drives. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 2 QuickSpecs HP ProLiant DL560 Standard Features Processor One of the following depending on Model (2P) Intel Xeon Processor MP 3.0 GHz/4MB (Expandable to 4 processors) (2P) Intel Xeon Processor MP 2.7 GHz/2MB (Expandable to 4 processors) (1P) Intel Xeon Processor MP 2.2 GHz/2MB (Expandable to 4 processors) (1P) Intel Xeon Processor MP 2.0 GHz/1MB (Expandable to 4 processors) Cache Memory One of the following depending on Model 4MB Integrated Level 3 Cache NOTE: 3.0 GHz Models only. 2MB Integrated Level 3 Cache NOTE: 2.7 GHz and 2.2 GHz Models only. 1MB Integrated Level 3 Cache NOTE: 2.0 GHz Models only. Upgradability Upgradable to quad processing Chipset ServerWorks Grand Champion-LE chipset NOTE: For more information regarding ServerWorks, please see the following URL: http://www.serverworks.com/products/overview.html. Memory One of the following depending on Model Type 200-MHz (DDR) SDRAM PC2100 Registered SDRAM Memory with Advanced ECC functionality Standard 1024 MB Maximum 12 GB NOTE: Advanced ECC Memory Technology protects the data even in the event of an entire SDRAM component failure. Embedded in the chipset design, this feature allows the use of Industry-Standard Registered DIMMs. Network Controller Two NC7781 PCI-X Gigabit NICs (embedded) Expansion Slots I/O (3 Total, 3 Available) 64-bit/100-MHz PCI Non-Hot Plug 64-bit/133-MHz PCI-X Non-Hot Plug Manageability PCI Voltage: 2 and 3 3.3 Volt only 1 3.3 Volt only Integrated Lights-Out (iLO) Standard Management (ASIC on the System Board) DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 3 QuickSpecs HP ProLiant DL560 Standard Features Storage Controllers Smart Array 5i Plus Controller, Ultra3 (supports RAID 0, 1, across internal hard disk drives) with 64 MB of memory 64-MB total memory for code, transfer buffers, and read/write cache on the 5i Plus Memory Module Connector for Battery Backed Write Cache (BBWC) Enable NOTE: The Smart Array 5i Plus Controller is integrated on the system board and is designed to support the simplex drive cage. An external SCSI port is not available on the HP ProLiant DL560. External SCSI solutions require the addition of a PCI or PCI-X option card. Storage Data Protection The Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory from hard boot, power, controller, or system board failures. Standard on HP ProLiant DL560 2P Models, optional on 1P Models Battery charge/life: Up to 72 hours/ 3 years Transportable data protection Increases overall controller performance NOTE: Safely transport your write cache data to another HP ProLiant DL560 in the data center be removing the BBWC Enabler and 5i Plus Memory Module simultaneously (connected by short cable). Storage Diskette Drive Optical Drive Hard Drives Maximum Internal Storage Hard Disk Drive Backplane 1.44 MB Diskette Drive 24x IDE CD-ROM Drive (slimline) – ejectable for security and serviceability None 600 GB (2 x 300 GB Ultra320 1" SCSI drives) (internal hot plug Ultra3 drive cage) Internal Wide Ultra3 backplane supports up to two 1" hard disk drives Interfaces Serial Pointing Device (Mouse) Graphics Keyboard Rear USB Ports iLO Remote Management Network RJ-45 USB 1.0 1 1 1 1 2 1 2 1 Graphics Integrated 1280 x 1024, 16M color on PCI local bus, 8-MB of SDRAM video memory Form Factor Rack (2U = 3.5 inches), ships with sliding rails and cable management system Space saving form factor (2U) provides space efficiencies while providing maximum deployment flexibility ProLiant Essentials Foundation Pack Software DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 4 QuickSpecs HP ProLiant DL560 Standard Features ProLiant Essentials Foundation Pack Software HP Systems Insight Manager HP's new HP Systems Insight Manager (HP SIM) helps maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM are both easy to set up work with the Insight Management Agents, integrated Lights-Out and Remote Insight Lights-Out Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP SIM customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP SIM visit http://www.hp.com/go/hpsim. SmartStart SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 6.20. Management Agents The Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to indepth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from HP, please visit the management Web site at http://www.hp.com/servers/manage. Subscriber's Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides automatic delivery of software and driver change notifications for ProLiant products. Sign up at http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. ROMPaq, support software, and configuration utilities The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options available in SmartStart or downloadable from Software and Drivers download pages, linked from the SmartStart website at www.hp.com/servers/smartstart. Survey Utility and diagnostics utilities The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in SmartStart. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 5 QuickSpecs HP ProLiant DL560 Standard Features Optional ProLiant Essentials Value Packs Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs: Rapid Deployment Pack - an automated solution for multi-server deployment and provisioning, enabling companies to quickly and easily adapt to changing business demands. Workload Management Pack - provides easier management of complex environments, improving overall server utilization and enabling Windows® 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server. Integrated Lights-Out Advanced Pack - upgrades the Integrated LightsOut processor to full virtual presence and control with graphical console and virtual media. Performance Management Pack - a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources. Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages and steers traffic to the optimum route based on network conditions, plus it provides an extra layer of protection. The virus throttle feature of the solution slows the propagation of fast spreading virus Vulnerability and Patch Management Pack - identifies and remediates software security vulnerabilities due to missing patches as well operating system configurations that can be exploited by viruses, worms, and other blended threats Virtual Machine Management Pack - provides central management and control of virtual machines from Microsoft and VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management console. NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials Industry Standard Compliance ACPI 2.0 Compliant PCI 2.2 Compliant PXE Support WOL Support Physical Address Extension (PAE) Support Microsoft® Logo certifications DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 6 QuickSpecs HP ProLiant DL560 Standard Features Intelligent Manageability Integrated Lights-Out (iLO) Standard Management Virtual Text Remote Console Virtual Power Button Control Dedicated LAN Connectivity Automatic IP Configuration via DHCP/DNS/WINS Industry Standard 128-bit Secure Sockets Layer (SSL) Security IML and iLO Event Logging Support for 12 user accounts with customizable access privileges Integrated Lights-Out (iLO) Advanced Pack (supports Advanced features such as Graphical Remote Console and Virtual Floppy - available as a separate option) Automatic Server Recovery-2 (ASR-2) HP Systems Insight Manager Redundant ROM Remote Flash ROM ROM-Based Setup Utility (RBSU) Integrated Management Log (IML) Hot Spare Boot NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s). Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Redundant/adaptive load balancing NIC Support Availability Standard Advanced ECC functionality detects and corrects single bit and specific multi-bit memory errors (4bit and 8bit) while using industry standard registered DIMMS. Functionality is embedded in the chipset design. HP Advanced Memory Protection Technology – delivers unsurpassed memory protection and server availability: Online Spare Memory: Offers a higher level of memory protection than Advanced ECC alone. If the number of single-bit correctable errors on a bank exceeds the pre-defined error threshold, that bank will fail over to the online spare bank without intervention or server interruption. The failed memory can then be replaced at the user's convenience during a scheduled maintenance window. NOTE: All HP Advanced Memory Protection modes are user configurable through the ROM-Based Setup Utility (RBSU) and viewable through Insight Manager 7 and the Integrated Management Log (IML.). Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler provides transportable data protection and increases overall controller performance. Up to 64MB Battery Backed Write Cache protection available on 2P HP ProLiant DL560 models (BBWC Enabler is optional on 1P model). Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide 7x24 cooling. Each zone is independent of each other and is able to support N+1 redundancy, as indicated below. This zone configuration enables the server to withstand up to three fan failures, provided that they are not within the same zone. Each fan is hot plug redundant and individually removable. Up to two Hot Plug Ultra3 Drive Bays Simplex SCSI Backplane Dual Hot Plug Redundant Power Supplies (standard on 2P Models, one ships standard on 1P Models) DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 7 QuickSpecs HP ProLiant DL560 Standard Features Serviceability Innovative Diagnostic Lighting LED display on front panel indicates power, internal health, external health, Unit ID light. Tool-less, virtually cable-less interior design Tool-less access to interior of server Lift up hood access to processors and primary fans Ejectable, slimline media drives (and CD-ROM standard with support for optional DVDROM drives) is removable without the use of tools. Also has fixed floppy drive. PCI Card Guides locks full length PCI cards in place during transit Up to ten individually removable fans connect without cables to the system board Processor/VRM Retention mechanism securely locks both processor and VRM into their respective sockets Tool-less removal of system board Quick Deploy Rails Tool-less design "snap in" rail Security Power-on password Keyboard password Diskette drive control Diskette boot control Network Server Mode Security Provision Serial interface control Administrator's password Disk configuration lock Hot plug access security Removable Diskette drive Removable CD-ROM drive UPS and PDU Power Cord Matrix Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications for UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. Power Supply 550-Watt (low line or high line) Hot Plug Power Supply NOTE: One 550-Watt Hot Plug Power Supply ships standard with 1P Models (optional Redundant Hot Plug Power Supply Option Kit). NOTE: Two 550-Watt Hot Plug Power Supplies ship standard with 2P Models. System Fans Standard 5 Hot plug, redundant fans on 1P models (individually removable) Maximum 10 Hot plug, redundant fans on 2P models (individually removable) Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide 7x24 cooling. Each zone is independent of each other and is able to support n+ 1 redundancy, as indicated below: PCI-X expansion zone is 1+ 1 redundant (fans 1 and 2) System can run fully loaded with five fans. This zone configuration enables the server to withstand up to three fan failures, provided that they are not within the same zone. Each fan is hot plug redundant and individually removable. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 8 QuickSpecs HP ProLiant DL560 Standard Features Required Cabling For required cabling information, refer to the HP Web site at http://h18000.www1.hp.com/products/servers/proliantDL560/. OS Support Microsoft Windows 2000 Windows Server 2003 Novell NetWare LINUX (Red Hat, SuSE) UnitedLinux VMware Virtualization Software NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL560, please see: http://www.HP.com/support/files/server/us/index.html. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux website at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. Rack Airflow Requirements Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm). CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://www5.HP.com/products/servers/proliantdl560/index.html. Rack Mounting Requirements Tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and H9 series), with an adjustment range of 24"– 36". DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 9 QuickSpecs HP ProLiant DL560 Standard Features Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. Custom Builder Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. Service and Support This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year on-site support. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including: Installation and start up Education courses Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWare-based IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours. System Management, Performance Services and Mission Critical Support Solution HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3KVA. 22" and smaller external monitors will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 10 QuickSpecs HP ProLiant DL560 Standard Features NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack NOTE:For more complete information on HP Services offerings, customers and resellers, please visit us NOTE: at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 11 QuickSpecs HP ProLiant DL560 Models DL560R01 X3.0GHz4MB, 1024MB (2P) 346921-xx1 Processor(s) Cache Memory Memory Network Controller Storage Controller Manageability Hard Drives Internal Storage Power Supply Optical Drive Diskette Drive Form Factor DL560R01 X2.7-2MB, 1024MB (2P) 346920-xx1 Processor(s) Cache Memory Memory Network Controller Storage Controller Manageability Hard Drives Internal Storage Power Supply Optical Drive Diskette Drive Form Factor DA - 11595 (2) Intel Xeon Processors MP at 3.0 GHz standard (up to 4 supported) 4MB Integrated Level 3 Cache 1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum) Two NC7781 PCI-X Gigabit NICs (embedded) Smart Array 5i Plus Controller (Ultra3) with Battery-Backed Write Cache Enabler (integrated on system board) Integrated Lights-Out (iLO) Standard management (integrated on system board) None ship standard 293.6 GB maximum (with optional hard drives) Two 550W Hot Plug Redundant Power Supplies (low line or high line) 24x IDE slimline CD-ROM Drive 1.44 MB Diskette Drive Rack 2U (2) Intel Xeon Processors MP at 2.7 GHz standard (up to 4 supported) 2MB Integrated Level 3 Cache 1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum) Two NC7781 PCI-X Gigabit NICs (embedded) Smart Array 5i Plus Controller (Ultra3) with Battery-Backed Write Cache Enabler (integrated on system board) Integrated Lights-Out (iLO) Standard management (integrated on system board) None ship standard 293.6 GB maximum (with optional hard drives) Two 550W Hot Plug Redundant Power Supplies (low line or high line) 24x IDE slimline CD-ROM Drive 1.44 MB Diskette Drive Rack 2U Worldwide — Version 46 — December 16, 2005 Page 12 QuickSpecs HP ProLiant DL560 Models DL560R01 X2.2-2MB, 1024MB (1P) 346919-xx1 Processor(s) Cache Memory Memory Network Controller Storage Controller Manageability Hard Drives Internal Storage Power Supply Optical Drive Diskette Drive Form Factor DL560R01 X2.0-1MB, 1024MB (1P) 246638-xx2 Processor(s) Cache Memory Memory Network Controller Storage Controller Manageability Hard Drives Internal Storage Power Supply Optical Drive Diskette Drive Form Factor Country Code Key XX=00 XX=01 XX=03 XX=20 XX=29 XX=37 XX=42 XX=AA (1) Intel Xeon Processor MP at 2.2 GHz standard (up to 4 supported) 2MB Integrated Level 3 Cache 1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum) Two NC7781 PCI-X Gigabit NICs (embedded) Smart Array 5i Plus Controller (Ultra3) (integrated on system board) Integrated Lights-Out (iLO) Standard management (integrated on system board) None ship standard 293.6 GB maximum (with optional hard drives) One 550W Hot Plug Redundant Power Supplies (low line or high line) 24x IDE slimline CD-ROM Drive 1.44 MB Diskette Drive Rack 2U (1) Intel Xeon Processor MP at 2.0 GHz standard (up to 4 supported) 1MB Integrated Level 3 Cache 1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum) Two NC7781 PCI-X Gigabit NICs (embedded) Smart Array 5i Plus Controller (Ultra3) (integrated on system board) Integrated Lights-Out (iLO) Standard management (integrated on system board) None ship standard 293.6 GB maximum (with optional hard drives) One 550W Hot Plug Redundant Power Supplies (low line or high line) 24x IDE slimline CD-ROM Drive 1.44 MB Diskette Drive Rack 2U US Australia UK Brazil EURO APD Int'l, Europe, Germany, France PRC DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 13 QuickSpecs HP ProLiant DL560 Options ProLiant Essentials Value Pack Software ProLiant Essentials Integrated Lights-Out Advanced Pack ProLiant Essentials Integrated Lights-Out Advanced Pack, 1 server Featuring: sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. NOTE: For additional ProLiant Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.HTML ProLiant Essentials Intelligent Networking Pack ProLiant Essentials Intelligent Networking Pack - Windows Edition, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. NOTE: For additional ProLiant Intelligent Networking Pack - Windows License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.HTML ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License NOTE: For additional ProLiant Intelligent Networking Pack - Linux License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.HTML ProLiant Essentials Performance Management Pack ProLiant Essentials Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.HTML ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition Release Rapid Deployment Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. Rapid Deployment Pack, Single-Server License (Japan) NOTE: This license allows 1 server to be deployed and managed via RDP. NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.HTML http://h18000.www1.hp.com/products/quickspecs/11713_div/11713_div.HTML ProLiant Essentials Workload Management Pack ProLiant Essentials Workload Management Pack, Single Server License NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.HTML ProLiant Essentials Virtualization Management Software ProLiant Essentials Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. DA - 11595 Worldwide — Version 46 — December 16, 2005 263825-B21 372906-B21 397004-B21 306696-B21 267196-B21 267196-291 303284-B21 372214-B21 Page 14 QuickSpecs HP ProLiant DL560 Options ProLiant Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.HTML ProLiant Essentials Vulnerability and Patch Management Pack ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. 375345-B21 371645-B21 NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.HTML NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. Processor Intel Xeon MP X3.0/4MB Processor Option Kit Intel Xeon MP X2.70/2MB Processor Option Kit Intel Xeon MP X2.20/2MB Processor Option Kit Intel Xeon MP X2.80/2MB Processor Option Kit Intel Xeon MP X2.50/1MB Processor Option Kit Intel Xeon MP X2.0/1MB Processor Option Kit 346990-B21 346989-B21 346988-B21 331004-B21 331003-B21 331002-B21 Memory (DIMMs) 4 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB) 2 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB) 1 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB) 512 MB of PC2100 ECC DDR DIMM Memory Kit (2 x 256 MB) 300682-B21 300680-B21 300679-B21 300678-B21 Optical Drives Slimline CD-RW/DVD-ROM Combo Drive Option Kit Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers) HP DVD+R/RW 8X Slim 331903-B21 264007-B21 383975-B21 DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 15 QuickSpecs HP ProLiant DL560 Options Hard Drives Storage Controller Ultra320 SCSI - Universal Hot Plug 300-GB 10,000 rpm U320 Universal Hard Drive (1") 146.8-GB 10,000 rpm U320 Universal Hard Drive (1") 72.8-GB 10,000 rpm U320 Universal Hard Drive (1") 146.8-GB 15,000 rpm U320 SCSI Hard Drive (1") 72.8-GB 15,000 rpm U320 Universal Hard Drive (1") 36.4-GB 15,000 rpm U320 Universal Hard Drive (1") NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: U320 Hard Drive QS: http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.HTML (North America) 350964-B22 286716-B22 286714-B22 347708-B22 286778-B22 286776-B22 Smart Array 6402/128 Controller Smart Array 6404/256 Controller 512MB DDR BBWC Upgrade Smart Array 641 Controller Smart Array 642 Controller 256-MB Battery-Backed Cache Module NOTE: This 256-MB Battery-Backed Cache Module supports the Smart Array 5300 series controllers, HP StorageWorks Modular Smart Array 1000 and the HP StorageWorks Modular Array 500. Battery-Backed Write Cache Enabler Option Kit NOTE: This Battery-Backed Write Cache Enable Option Kit (PN 255514-xx1) is optional for the HP ProLiant DL560 1P Model only. Battery-Backed Write Cache Enabler Option Kit (Japan) NOTE: NOTE This Battery-Backed Write Cache Enable Option Kit (PN 255514-xx1) is optional for the HP ProLiant DL560 1P Model only. 128MB Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS Ultra320 Expansion Module for SA-6402 273915-B21 273914-B21 372538-B21 291966-B21 291967-B21 254786-B21 DA - 11595 Worldwide — Version 46 — December 16, 2005 255514-B21 255514-291 351580-B21 268351-B21 284688-B21 273911-B21 Page 16 QuickSpecs HP ProLiant DL560 Options NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional information: http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.HTML (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/12067_div/12067_div.HTML (Smart Array 641) http://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.HTML (Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML (SCSI Adapter) http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML (U320 Adapter) Communications HP NC310F PCI-X 1000SX Gigabit Server Adapter HP NC1020 PCI 1000T Gigabit Server Adapter HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter HP NC7771 PCI-X 1000T Gigabit Server Adapter NOTE: Any NIC on the option list can be used for redundancy with the embedded NC7781 Network Controller 368169-B21 353377-B21 313881-B21 290563-B21 Redundant Options Hot Plug Redundant Power Supply Option Kit Hot Plug Redundant Power Supply Option Kit (EMEA) Hot Plug Redundant Fan Option Kit 267555-001 267555-B21 288635-B21 Management Options Remote Insight Lights-Out Edition II (NA, LA) Remote Insight Lights-Out Edition II (EMEA) Remote Insight Lights-Out Edition II (ROW) 227251-001 227251-021 227251-371 Tape Drives NOTE: For the complete listing of Tape Drive offerings for this server, please visit: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For recommended tape drive offerings for this ProLiant server see the following: Hot Plug Tape Drives HP StorageWorks DAT 72 SCSI Hot-plug Tape Drive (Carbon) USB Tape Drives HP StorageWorks DAT 72 USB External Tape Drive (Carbonite) External and Rack-Mount Ultrium Tape Drives HP StorageWorks Ultrium 232 Internal Tape Drive (Carbonite) NOTE: No internal tape drives fit inside this HP ProLiant server (except hot plug tape). The internal drive shown here is for the 1U and 3U Rack-mount Kit. HP StorageWorks Ultrium 232 External Tape Drive (Carbonite) HP StorageWorks Ultrium 232 External Tape Drive (Carbonite) HP StorageWorks 1U Rack-mount kit with one Ultrium 448 (Carbonite) DA - 11595 Worldwide — Version 46 — December 16, 2005 Q1529A DW027A DW064A DW065B DW065B DW028A Page 17 QuickSpecs HP ProLiant DL560 Options HP StorageWorks Ultrium 960 External Tape Drive (Carbonite) HP StorageWorks 3U Rack-mount kit with one Ultrium 960 (Carbonite) NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional options such as controllers, media, and other related items: http://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html (Worldwide) http://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html (North America) For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect. Rack-Mount Tape Drive Enclosures HP StorageWorks 1U Rack-Mount Kit NOTE: The 1U Rack-mount Kit can support up to (2) half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including the DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232 and Ultrium 448 tape drives. HP StorageWorks 1U USB Rack-Mount Kit 1U USB Cable Option Kit NOTE: Converts a 1U SCSI rack-mount kit to a USB interface to support the USB tape drives. HP StorageWorks 3U Rack-Mount Kit NOTE: The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, SDLT 320, SDLT 600, Ultrium 215, Ultrium 230, Ultrium 232, Ultrium 460, Ultrium 448 and Ultrium 960 tape drives. NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional information regarding these kits: http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.HTML (North America) Tape Autoloaders DAT Autoloader HP StorageWorks DAT 72x6 External Autoloader NOTE: Please see the DAT Tape Autoloader QuickSpecs for additional options such as host bus adapters, controllers and media: http://h18000.www1.hp.com/products/quickspecs/11985_div/11985_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.HTML (North America) HP StorageWorks 1/8 Tape Autoloader HP StorageWorks 1/8 Ultrium 960 Tape Autoloader HP StorageWorks 1/8 Ultrium 448 Tape Autoloader HP StorageWorks 1/8 SDLT 320 Tape Autoloader HP StorageWorks 1/8 Ultrium 232 Tape Autoloader 1/8 Tape Autoloader Rackmount Kit NOTE: Required to install the unit in a standard 19-inch rack; includes rails and rackmount instructions DA - 11595 Worldwide — Version 46 — December 16, 2005 Q1539B Q1595A A7445B A8007A 396114-B21 274338-B23 Q1567A AF204A AF203A AA926A AF202A C9268R Page 18 QuickSpecs HP ProLiant DL560 Options NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs HP StorageWorks SSL1016 Tape Autoloader HP StorageWorks SSL1016 Ultrium 460 Tape Autoloader HP StorageWorks SSL1016 SDLT 320 Tape Autoloader NOTE: Please reference the SSL1016 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs Tape Libraries Magneto-Optical Jukeboxes HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 1 Ultrium 960 Drive Library HP StorageWorks MSL2024 1 Ultrium 448 Drive Library HP StorageWorks MSL2024 2 Ultrium 448 Drive Library HP StorageWorks MSL6000 Tape Library Ultrium 960 technology HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library Ultrium 460 technology HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library NOTE: Please reference the MSL2024 and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. 330821-B21 330816-B21 AG115A AG116A AG117A AD606A AD608A AD607A AD609A AD598A AD600A AD599A AD601A HP StorageWorks 9.1 GB Optical Jukeboxes 600mx, 4 drive, 64 slot jukebox 1200mx, 4 drive, up to 128 slots 2200mx, 6 drive, up to 238 slots NOTE: Please see the HP StorageWorks Magneto-Optical Products data sheet for a complete listing of available jukeboxes at: http://www.hp.com/products1/storage/products/archivalprod/brochures/ MO_family_pb.pdf NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution. DA - 11595 Worldwide — Version 46 — December 16, 2005 C1160M C1104M C1107M Page 19 QuickSpecs HP ProLiant DL560 Options Ultra Density Optical Jukeboxes 1900ux, 4 drive, 64 slot jukebox 3800ux, 4 drive, 128 slot jukebox 7100ux, 6 drive, 238 slot jukebox NOTE: Please see the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs for a complete listing of available jukeboxes at: http://h18006.www1.hp.com/products/quickspecs/11944_div/11944_div.html NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at http://www.hp.com/go/optical for additional information needed to create a complete solution Cluster Options ProLiant Cluster Starter Kit NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html (Worldwide) ProLiant Cluster Kit with OpenView Storage Mirroring NOTE: For additional information regarding the ProLiant Cluster Kit with OpenView Storage Mirroring please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11934_na/11934_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11934_div/11934_div.html (Worldwide) HP HA/F200 for Entry SAN Cluster HP HA/F200 for Entry SAN Cluster (Japan) NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html (Worldwide) ProLiant Cluster HA/F500 for the Enterprise SAN NOTE: For additional information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11933_div/11933_div.html (Worldwide) HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and Red Hat EL 3 (2 node license cluster kit) HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL & 4 (2 node license cluster kit) HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and Red Hat EL 3 (single license version) HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 & 4 (single license version) DA - 11595 Worldwide — Version 46 — December 16, 2005 AA966A AA969A AA971A 364023-B21 364025-B21 364026-B22 364026-292 364024-B21 305199-B24 305199-B26 307754-B24 307754-B26 Page 20 QuickSpecs HP ProLiant DL560 Options NOTE: For additional information regarding the HP Serviceguard for Linux License, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) HP StorageWorks Modular Smart Array 20 HP StorageWorks Modular Smart Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. HP StorageWorks Modular Smart Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. 335921-B21 366172-B21 NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1" Hot Plug Hard Drives. HP StorageWorks Modular Smart Array 30 HP StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies HP StorageWorks Modular Smart Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 1" Hot Plug Hard Drives. 302969-B21 302970-B21 HP StorageWorks HP StorageWorks Modular Smart Array 500 Generation 2 Modular Smart Array 500 NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.HTML (North America) http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.HTML (Worldwide) 335880-B21 HP StorageWorks Modular Smart Array 1000 HP StorageWorks Modular Smart Array 1000 NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options and configuration information at http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML (North America) http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide) 201723-B22 HP StorageWorks Modular Smart Array 1500 cs Modular Smart Array 1500 Controller Shelf NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options and configuration information at: http://www.hp.com/go/MSA1500cs DA - 11595 Worldwide — Version 46 — December 16, 2005 AA986A Page 21 QuickSpecs HP ProLiant DL560 Options StorageWorks Options StorageWorks SAN Switch 2/16 StorageWorks SAN Switch 2/16-EL Upgrade Kit StorageWorks Director 2/64 NOTE: Please see the StorageWorks Director 2/64 QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/11003_na/11003_na.HTML (North America) http://h18000.www1.hp.com/products/quickspecs/11003_div/11003_div.HTML (Worldwide) 322118-B21 325889-B21 286809-B21 Uninterruptible Power Systems – Rack HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA) HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int’l) HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan) HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA) HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA) HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan) HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan) HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int’l - detachable cord) HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug) HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO Plug) HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug) HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage (NA/Jpn) HP UPS R5500 XR, (6000VA, 5400 Watt), High Voltage (Int'l) UPS R12000 XR N+x (200-240V) (WW-hardwired) NOTE: The UPS R12000 XR has a hardwired input and output connection. 204404-001 204404-B31 204404-291 192186-001 192186-002 192186-291 192186-292 192186-B31 192186-B32 192186-B33 HP Monitored Power Distribution Unit (PDU) HP Monitored Power Distribution Unit: Full Rack Version HP PDU with Power Monitoring, Model S2324 - dual input, 3-phase, 24A (NA/JPN) HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3 phase, 24A (NA/JPN) HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1 phase, 40A (NA/JPN) HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1 phase, 40A (NA/JPN) HP Power Distribution Unit with Power Monitoring Model S2316 - dual input, 3 phase, 16A (INTL) HP Power Distribution Unit with Power Monitoring Model S1316 - single input, 3 phase, 16A (INTL) HP Power Distribution Unit with Power Monitoring Model S2132 - dual input, 1 phase, 32A (INTL) HP Power Distribution Unit with Power Monitoring Model S1132 - single input, 1 phase, 32A (INTL) HP Monitored Power Distribution Unit: Half Rack Version HP PDU with Power Monitoring, Model S1348 - single input, 3-phase, 60A (NA/JPN) DA - 11595 Worldwide — Version 46 — December 16, 2005 192186-AR1 326529-D71 326529-B31 207552-B22 370959-D71 370960-D71 370961-D71 370962-D71 370963-B31 370964-B31 370965-B31 370966-B31 AF916A Page 22 QuickSpecs HP ProLiant DL560 Options HP PDU with Power Monitoring, Model S1332 - single input, 3-phase, 32A (INTL) Modular Power Distribution Units 1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). AF917A HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan) HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int’l) HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC) (WW) NOTE: This mPDU (252663-B21), 40A model has a hardwired input. 252663-D71 HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC) (WW) NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000 For North America, need to order cable PN 340653-001 NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs for additional options including shorter jumper cables and country specific power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML (North America) http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML (Worldwide) 252663-B24 USB Options USB 2-Button Optical Scroll Mouse (Carbonite/Silver) USB 1.44-MB External Diskette Drive (Carbonite) Third Party Rack Kit Rack Adapter Kit NOTE: This kit allows HP rack servers to fit in racks that are 24" wide. DA - 11595 Worldwide — Version 46 — December 16, 2005 252663-D72 252663-B31 252663-B21 DC172B DC141B 332815-B21 Page 23 QuickSpecs HP ProLiant DL560 Options HP Rack 10000 Series (Graphite Metallic) 10642 (42U) Infrastructure Rack (Low Voltage) 10642 (42U) Infrastructure Rack (High Voltage) HP Rack S10614 (14U) Rack Cabinet – Shock Pallet HP Rack 10842 (42U, 800mm wide) – Pallet HP Rack 10842 (42U, 800mm wide) – Shock Pallet HP Rack 10647 (47U) – Pallet HP Rack 10647 (47U) – Crated HP Rack 10642 (42U) – Pallet HP Rack 10642 (42U) – Shock Pallet HP Rack 10642 (42U) – Crated HP Rack 10636 (36U) – Pallet HP Rack 10636 (36U) – Shock Pallet HP Rack 10636 (36U) – Crated HP Rack 10622 (22U) – Pallet HP Rack 10622 (22U) – Shock Pallet HP Rack 10622 (22U) – Crated NOTE: -B21 (pallet) used to ship empty racks shipped on a truck NOTE -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as NOTE height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML (North America) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rackoptions/index.html. 379006-001 379005-001 292302-B22 257415-B21 257415-B22 245160-B21 245160-B23 245161-B21 245161-B22 245161-B23 245162-B21 245162-B22 245162-B23 245163-B21 245163-B22 245163-B23 Rack Options for HP Rack 10000 Series HP Rack Light Kit (Neon) HP Rack Plinth Kit (Carbon) 42U Side Panel – Graphite Metallic 36U Side Panel – Graphite Metallic 47U Side Panel – Graphite Metallic TFT7210R Rack Mounted 17" Monitor NOTE: For a complete list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/. TFT5600 Rack Keyboard Monitor NOTE: For a complete list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/. 1U Rack Keyboard & Drawer (Carbon) Country Code Key (for TFT5600 Rack Keyboard Monitor (PN 221546-xx1 and for 1U Rack Keyboard & Drawer (PN 257054-xx1) 361589-B21 251960-B21 246099-B21 246102-B21 255486-B21 348373-B21 DA - 11595 Worldwide — Version 46 — December 16, 2005 221546-xx1 257054-xx1 Page 24 QuickSpecs HP ProLiant DL560 Options XX = 001 XX = 031 XX = 041 XX = 051 XX = 061 XX = 071 XX = 081 US UK Germany France Italy Spain Denmark XX = 091 XX = 101 XX = 111 XX = 131 XX = 181 XX = 291 XX = B31 Norway Sweden/Finland Switzerland Portugal Belgium Japan International NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rackoptions/index.html. HP KVM Switch Options IP Console Switch Box (KVM/IP), 3 x 1 x 16 IP Console Switch Box (KVM/IP), 1 x 1 x 16 Server Console Switch (KVM), 0 x 1 x 8 port Server Console Switch (KVM), 0 x 2 x 16 port PS/2 Interface Adapter, 1 pack PS/2 Interface Adapter, 8 pack USB Interface Adapter, 1 pack Serial Interface adapter - 1 Pack with power supply NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. HP 1x 4 USB/PS2 KVM Switch, TT (NA/JPN) HP 1x 4 USB/PS2 KVM Switch, TT (AU/NZ) HP 1x 4 USB/PS2 KVM Switch, TT (UK) HP 1x 4 USB/PS2 KVM Switch, TT (EU) HP 1x 4 USB/PS2 KVM Switch, RM (ALL) HP PS2 KVM Cable with audio, 6', 2-pack HP USB KVM Cable with audio, 6', 2-pack NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. HP Serial Console Server HP 16 Port Serial Console Server (worldwide) Options HP 48 Port Serial Console Server (worldwide) Serial Adapter, RJ45-DB9 DCE Female, 1 Pack Serial Adapter, RJ45-DB9 DCE Female, 8 Pack NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. DA - 11595 Worldwide — Version 46 — December 16, 2005 AF101A AF102A AF103A AF110A Page 25 QuickSpecs HP ProLiant DL560 Options Rack Options for Third party Cabinet Racks Round hole rack cabinet rail kit NOTE: Support for racks with round mounting holes (include HP Rack System /E and HP Systems) with and adjustment range of 24 inches to 36 inches (60.96 cm to 91.44 cm). Service and Support Hardware Services On-site Service Offerings (HP Care Pack 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic Services) 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic Installation & Start-up Services Hardware Installation, Electronic Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am5pm, M-F, excl. HP holidays, Electronic Support Plus Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic Onsite HW support, 8am-9pm, M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic Support Plus 24 Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic Onsite HW support 24x7, 4hr response and Linux O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic 293052-B21 U4697E U4698E U4699E U4707E U4708E U4709E U4711E U4710E U4712E NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 26 QuickSpecs HP ProLiant DL560 Memory HP ProLiant DL560 Standard Memory 1024 MB PC2100 Registered DDR SDRAM DIMM Memory comes installed (2 x 512 MB SDRAM) Standard Memory Plus Optional Memory Up to 9216 MB memory is available with the optional installation of PC2100 Registered DDR SDRAM DIMM Memory Option Kit Standard Memory Replaced with Optional Memory Up to 12,288 MB of memory is available with the removal of the standard 1024 MB of memory, the optional installation of PC2100 Registered DDR SDRAM DIMM Memory Option Kit NOTE: This chart does not represent all possible memory configurations. Memory Standard 1024 MB Optional 9,216 MB Maximum 12,288 MB 1 512 MB 512 MB 2048 MB 2 512 MB 512 MB 2048 MB Standard Memory Board (Slots) 3 4 Empty Empty 2048 MB 2048 MB 2048 MB 2048 MB The following memory options are available from HP: 512 MB of PC2100 ECC DDR DIMM Memory Kit (2 x 256 MB) 1 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB) 2 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB) 4 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB) DA - 11595 Worldwide — Version 46 — December 16, 2005 5 Empty 2048 MB 2048 MB 6 Empty 2048 MB 2048 MB 300678-B21 300679-B21 300680-B21 300682-B21 Page 27 QuickSpecs HP ProLiant DL560 Storage A 1.44-MB Diskette Drive B Ejectable: 24x IDE CD-ROM (Slimline) 0-1 Wide Ultra3/Ultra320 Drive Cage Drive Support Quantity Supported Slim Line Drives 1.44-MB slim-line Diskette Up to 1 Drive Ejectable IDE slim-line Up to 1 CD-ROM Drive Slimline DVD-ROM Drive Up to 1 (8X/24X) Option Kit (ejectable) Position Supported Controller A Integrated B Integrated IDE B Integrated IDE Hard Drives Ultra320 Hot Pluggable Drives Position Quantity Supported Supported Controller 1-inch 300-GB 10,000 rpm Up to 2 0-1 Integrated Dual Channel Wide Ultra3 SCSI Adapter 146.8-GB 10,000 rpm Smart Array 6402/128Controller 72.8-GB 10,000 rpm Smart Array 641 Controller 146.8-GB 15,000 rpm Smart Array 642 Controller 72.8-GB 15,000 rpm 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 36.4-GB 15,000 rpm NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 28 QuickSpecs HP ProLiant DL560 Storage External Storage Modular Smart Array 20 Modular Smart Array 30 Family Quantity Supported 1 per SCSI VHDCI connector Up to 13 Position Supported External External Host Controller or Adapter Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS Please see the Modular Smart Array 500 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500 Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs Modular Smart Array 500 1 External G2 System Modular Smart Array Please see the External 1000 Modular Smart Array 1000 QuickSpecs below to determine configuration requirements Modular Smart Array Please see the External Please see the Modular Smart Array 1500 cs QuickSpecs (URL 1500 cs Modular Smart below) for the latest list of supported HBAs Array 1500 cs QuickSpecs below to determine configuration requirements Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML (North America) Modular Smart Array 1500: http://www.hp.com/go/MSA1500cs Maximum Storage Capacity – (External Enclosure Attached) Internal 600 GB (2 x 300 GB Ultra320 SCSI 1" Drives) External 50.40 TB (12 x (14 x 300 GB Ultra320 SCSI 1" Drives)) Total 51.00 TB Tape Drives, Tape Autoloaders, & Tape Libraries DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 29 QuickSpecs HP ProLiant DL560 Storage NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/North_America/10233.html (North America) http://h18000.www1.hp.com/products/quickspecs/Division/10233.html (Worldwide) NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/North_America/10809.html (North America) http://h18000.www1.hp.com/products/quickspecs/Division/10809.html (Worldwide) NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For details on connecting tape drives to this server, see the following: Quantity Supported 1 Position Supported 0, 1 HP StorageWorks Tape Drives, USB External DAT 24 USB DAT 40 USB DAT 72 USB 1 per USB port External USB port HP StorageWorks Tape Drives, External Ultrium 215 Ultrium 230 Ultrium 232 Ultrium 448 Ultrium 460 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 Up to 2 External 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS HP StorageWorks Tape Drives, External Ultrium 960 SDLT 600 1 drive per SCSI External channel 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS HP StorageWorks DAT Tape Drives, Internal Hot Plug DAT 40 Tape Drive DAT 72 Tape Drive DA - 11595 Controller Smart Array 5i Plus Controller (integrated on system board) 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS Worldwide — Version 46 — December 16, 2005 Page 30 QuickSpecs HP ProLiant DL560 Storage HP StorageWorks Autoloaders, External DAT 72x6 Tape Autoloader 1/8 Tape Autoloader SSL1016 Tape Autoloader 1 autoloader per External SCSI channel 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS HP StorageWorks Rackmount Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit 5U Rack-Mount Kit 1 per SCSI channel 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS HP StorageWorks Tape Libraries, External MSL2024 (Ultrium 960based) MSL2024 (Ultrium 448based) MSL6000 (Ultrium 960based) MSL6000 (SDLT 600based) MSL6000 (Ultrium 460based) MSL5026S2 (SDLT 320based) MSL5052S2 (SDLT 320based) Please reference External the MSL Tape Library QuickSpecs to determine configuration requirements DA - 11595 External Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. Worldwide — Version 46 — December 16, 2005 Page 31 QuickSpecs HP ProLiant DL560 Power Specifications Part Number Spare Kit Operational Input Voltage Range (V rms) Frequency Range (Nominal) (Hz) 280126-001 280126-B21 90 to 264 47 to 63 (50/60) Nominal Input Voltage (Vrms) Max Rated Output Wattage Rating Nominal Input Current (A rms) Max Rated Input Wattage Rating (Watts) Max. Rated VA (Volt-Amp) Efficiency (%) Power Factor Leakage Current (mA) Maximum Inrush Current (A peak) Maximum Inrush Current duration 100 550 7.1 696 710 79 0.98 .87 100 20 115 550 6.1 688 702 80 0.98 1.00 100 20 208 550 3.3 679 693 81 0.98 1.81 100 20 220 550 3.1 671 684 82 0.98 1.91 100 20 230 550 3.0 667 680 82.5 0.98 2.00 100 20 240 550 2.8 663 676 83 0.98 2.09 100 20 System Specifications HP ProLiant DL560 Fully Configured Up to 4 Processors, 6 Memory Slots, 2 Hard Drives, 3 PCI Slots, and 2 Hot Plug Power Supplies Nominal Input Voltage (Vrms) Fully Loaded System Input Wattage (W) Fully Loaded System Input Current (A rms) Fully Loaded System Thermal (BTU- Hr) Fully Loaded System VA (Volt-Amp) System Leakage with all power supplies loaded (mA) System Inrush Current with all power supplies loaded (A) Power cord requirements 100 534 5.4 1820 545 .87 115 527 4.7 1707 538 1.00 208 520 2.6 1774 531 1.81 220 514 2.4 1752 524 1.91 230 507 2.3 1730 518 2.00 240 501 2.1 1709 511 2.09 200 200 200 200 200 200 Nema 5-15P to IEC320-C13 IEC320-C13 to IEC320-C14 Option no./Spare no: 163719-002 Option no./Spare no: 142259-001/ 142258-B21 NOTES: NOTES ActiveAnswers Power Calculation Power calculator is LIVE on ActiveAnswers Web site. This is an external link. Follow this link: http://h30099.www3.hp.com/configurator/powercalcs.asp. To drill down to calculators: - Click on: "ProLiant Servers" Click on the Server of interest. Example: DL560 Click on: "Power Calculator" link (You may need to scroll down to see it.) DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 32 QuickSpecs HP ProLiant DL560 Technical Specifications System Unit Rack Chassis Footprint (HxWxD) Weight 3.38 x 17.50 x 25.75 in (8.59 x 44.45 x 65.41 cm) Maximum (2 Power 60 lb (27 kg) Supplies, 2 Hard Drives) Minimum (No hard drives 35 lb (16 kg) installed, one power supply) Input Requirements Rated Input Voltage 100 to 120 VAC/200 to 240 VAC Rated Input Frequency 50 to 60 Hz Input Power 690W @ 115 VAC/675W @ 230 VAC Rated Input Current 7A (100 VAC), 6A (115 VAC), 3A (230 VAC) Max BTU Rating 2375 BTU (550 Watts) Power Supply Output Rated Steady-State Power 550W/550W (lowline/highline) Power (per power supply) Maximum Peak Power 550W/550W (lowline/highline) Temperature Range Operating 50° to 95° F (10° to 35° C) Non-operating -20° to 140° F (-29° to 60° C) Shipping -22° to 122° F (-30° to 50° C) Relative Humidity Operating 10% to 70% (non-condensing) Non-operating 5% to 95% Maximum Wet Bulb 101.7° F (38.7° C) Temperature Acoustic Noise NOTE: Listed are the declared A-weighted sound power levels LWAd and the declared average bystander position sound pressure levels LpAm when operating in a 23° C ambient environment. Noise emissions were measured in accordance with ECMA 74 and declared in accordance with ECMA 109. Idle (Fixed Disk Drives Spinning) L WAd (BELS) 6.0 L pAm (dBA) 46 NOTE: These values apply to 2U rack configuration. Configuration tested included 2 processors, two 10, 000 rpm hard drive, 1 power supplies, 1 power supply fan and 4 CPU fans. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 33 QuickSpecs HP ProLiant DL560 Technical Specifications 24X Max (or higher) IDE CD-ROM Drive Slimline Disk Applicable Disk Capacity Block Size Interface Access Times (typical) Data Transfer Rate Cache Buffer Start-up Time (typical) Stop Time Laser Parameters Operating Conditions Dimensions Slimline CD-RW/DVDROM 24X Combo Drive (Multibay) Shipping Dimensions Shipping Weight Disk DA - 11595 Diameter Rotational Speed Center Hole Thickness Track Pitch Mode 1 Mode 2 CD-DA CD-XA IDE (ATAPI) Random Full-Stroke Sustained Burst 128 KB < 7seconds < 4seconds Type Wave Length Divergence Angle Output Power Temperature Humidity (HxWxD, maximum) Weight CD-DA, CD-ROM (Mode 1 and 2) CD-XA, CD-I (Mode 2, Form 1 and 2) Photo CD (Single and Multi-session) Mixed Mode (Audio and Data combined) 540 MB (Mode 1, 12 cm) 650 MB (Mode 2, 12 cm) 4.7 x 3.15 in/12 x 8 cm 4200 rpm maximum 0.6 in/15 mm diameter 1.2 mm 1.6 µm 2,048 2,340, 2,336, 1,024 bytes 2,352 bytes 2,328 bytes 100 ms 2000 ms 150 KB/s (sustained 1X) 2100 to 3600 KB/s Semiconductor Laser GaA1As 780 ± 25 nm 53.5° ± 1.5° 0.14 mW 41° to 113° F (5° to 45° C) 10% to 80% 1.69 x 5.75 x 8.19 in (4.29 x 15 x 20.8 cm) 2.66 lb (1.2 kg) 13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm) 5 lb (2.27 kg) DVD-ROM Applicable Disk DVD-R (Read Only) 2.6 GB/side DVD-RAM (Read Only) 5.2 GB/side DVD-RAM (Read Only) CD-ROM Mode-1 data disc CD-ROM Mode-2 data disc CD Audio disc CD-Extra CD-RW Worldwide — Version 46 — December 16, 2005 Page 34 QuickSpecs HP ProLiant DL560 Technical Specifications Capacity CD-R CD Text PhotoCD CD-I (mode 2) CD-I Ready CD-Bridge DVD-ROM DVD-SL DVD-DL Double Sided 4.7 GB/side 8.5 GB/side 9.40 GB/side DVD-R DVD-RAM Block Size Diameter Loading Mechanism Interface Access Times (typical) Audio Output Level (typical) Data Transfer Rate (sustained) Cache Buffer Spin-up Time (typical) MTBF Ambient Temperature Relative Humidity Dimensions Option Kit Contents DA - 11595 Tray type EIDE (ATAPI) Random Full-Stroke Line-out 3.95 GB/side 2.6 GB/side and 5.2 GB/ CD-ROM Mode-1 650 MB (550 MB) Mode-2 742 MB (640 MB) DVD 2,048 bytes CD 2,352 (Mode-0) 2352, 2340, 2336, 2048 bytes (Mode-1) 2352, 2340, 2336, 2048 bytes (Mode-2) 120 mm, 80 mm (with adapter at vertical mounting mode) DVD-ROM < 120 ms, CD-ROM < 110 ms DVD-ROM < 240 ms, CD-ROM < 160 ms CD 0.7 Vrms at 47 Kohms Load DVD-ROM Single Layer 10.8 MB/sec. Max. DVD-RAM 2.77 MB/sec. Max CD-ROM 7.2 MB/sec. Max. 2 MB less than 10 seconds 120,000 Power On Hours (POH) Operating -22° to 140° F (-30° to 60° C) Operating 10% to 80% Storage/Transportation 5% to 95% (HxWxD, maximum) 0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm) DVD-ROM drive with installation guide, warranty card, registration card Worldwide — Version 46 — December 16, 2005 Page 35 QuickSpecs HP ProLiant DL560 Technical Specifications Integrated Lights-Out Standard (integrated on system board) Architecture Processor Upgradability Video Support Interfaces Memory Operating System Support Client Browser Support iLO Standard Features iLO Advanced Features (optional) 32-bit PCI-based health and remote management ASIC (Application Specific Integrated Circuit) 32-bit RISC processor core running at 66 MHz Option firmware upgradable via flash ROM. Utilizes the host server's embedded video chip. Supports VGA/SVGA, 640 x 480 (256 to 16.7M colors), 800 x 600 (256 to 16.7M colors), 1024 x 768 (256 to 65K colors), 1280 x 1024 (256 colors) One Ethernet network connection (10/100 Mb/s) 2-MB Flash ROM 8-MB SDRAM United Linux 1.0 Windows 2000 Server Windows 2000 Advanced Server Red Hat 7.x SLES8 Novell NetWare 5.x, 6.x Microsoft Internet Explorer 5.5 or later. Virtual Text Remote Console Virtual Power Button Control Dedicated LAN Connectivity Automatic IP Configuration via DHCP/DNS/WINS Industry Standard 128-bit Secure Sockets Layer (SSL) Security IML and iLO Event Logging Support for up to 12 user accounts with customizable access privileges Virtual Graphical Remote Console Virtual Floppy Drive Integrated Smart Array 5i Data Compatible with all Yes Plus Controller Smart Array Controllers Instant Upgrades to other Yes Smart Array Controllers Yes Consistent Software Manageability Tools 64-bit, 100 MHz (integrated on system board) PCI-X Bus PCI-X Peak Data Transfer 800 MB/s Rate SCSI Protocols Supported Ultra3, Ultra2 SCSI Peak Data Transfer 160 MB/s per channel Rate 2 (only one connected) Channels 0/1 SCSI Ports (external/internal) 2 Drives Supported (maximum) NOTE: Maximum is the total number of internal drives on each specific ProLiant server. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 36 QuickSpecs HP ProLiant DL560 Technical Specifications Cache Battery-Backed Write Cache RAID Support Logical Drives (maximum) Online Configuration Online Capacity Expansion Logical Drive Capacity Extension Online Stripe Size Migration 64 MB Read and/or Write Cache Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB Online RAID Level Migration Online Spare Support Automatic Data Recovery Drive Roaming Redundant Controllers Yes Two NC7781 PCI-X Network Interface Gigabit NICs (embedded) Compatibility Server Adapter Data Transfer Method Network Transfer Rate Connector Cable Support 0, 1 Maximum = total number of drives Yes Yes Yes Yes Yes Yes Yes No 10/100/1000-T IEEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX 64-bit/133MHz PCI-X 10Base-T (Half-Duplex) 10 Mb/s 10Base-T (Full-Duplex) 20 Mb/s 100Base-TX (Half-Duplex) 100 Mb/s 100Base-TX (Full-Duplex) 200 Mb/s 1000Base-T (Full and 2000 Mb/s Half-Duplex) RJ-45 10Base-T Category 3,4 or 5 UTP up to 328 ft (100 m) 10/100/1000Base-T Category 5 UTP (2 pair); up to 328 ft (100 m) © Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 11595 Worldwide — Version 46 — December 16, 2005 Page 37 ">
/
Scarica
Solo un promemoria. Puoi visualizzare il documento qui. Ma soprattutto, la nostra IA l''ha già letto. Può spiegare cose complesse in termini semplici, rispondere alle tue domande in qualsiasi lingua e aiutarti a navigare rapidamente anche nei documenti più lunghi o complicati.
Pubblicità