Attention New Spa Owner!
Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa. These functions are listed below in an attempt to alleviate any operational concerns you may have during the first 24 hours of ownership! Also listed below are important maintenance recommendations you should observe on a regular basis to protect your new investment.
Automated Operations
Your new spa is equipped with an automated “clean-up” cycle that clears all plumbing lines daily to promote maximum water sanitation. Each day at 12:00
PM (noon), each pump will activate and run for one minute. If either pump has just finished a 20 minute time out, it will not automatically activate for the clean-up cycle.
Note: Turning off the corresponding jets pump that is running can deactivate the feature.
Maintain Healthy Spa Water
Always maintain your spa’s water chemistry within the following parameters:
With CLEARRAY® Without CLEARRAY® pH
Free Chlorine
Free Bromine
Total Alkalinity
Calcium Hardness
7.4-7.6
no less than 1.0 ppm no less than 2.0 ppm
100-150 ppm
150-250 ppm
7.4-7.6
3.0-4.0 ppm
2.0-4.0 ppm
100-150 ppm
150-250 ppm
IMPORTANT: CLEARRAY® Water Purification System is factory installed. If the CLEAR RAY® system is altered or is not operating efficiently then follow the
“without CLEAR RAY®” water chemistry parameters as defined by the Association of Pool and Spa Professionals. CLEAR RAY® requires an annual bulb replacement to properly sanitize your water.
!
TO DECREASE RISK OF INFECTION OR DISEASE! Always maintain
your spas filter as outlined below to ensure healthy spa water. Refer page 46
“Water Quality Maintenance” for additional information.
Required Filter Maintenance
Your new spa is equipped with an advanced water filtration system that provides unsurpassed water quality! To ensure maximum water quality at all times, you should clean both filter cartridges every month, or earlier as necessary. See page
39 for detailed filter cartridge cleaning/replacement instructions.
Required Water Replacement
!
TO DECREASE RISK OF INFECTION OR DISEASE! You should replace the spa’s water every 3 months. The frequency depends on a number of variables including frequency of use, number of users, and attention paid to water quality maintenance. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water, even though the key water balance measurements are all within the proper
parameters. See page 46 for additional information.
**Specifications and operations subject to change without notice.**
J-300
Table of Contents
1.0 Important Spa Owner Information ...................................1
2.0 FCC Notice ........................................................................1
3.0 Important Safety Instructions for all Spa Owners .........2
3.1 Entrapment Risk .................................................................6
3.2 Hyperthermia ......................................................................7
3.3 Important Additional CSA Safety Instructions
(Canada Only) ....................................................................8
3.4 General Electrical Safety Instructions .................................8
4.0 Choosing A Location ........................................................9
4.1 Outdoor Location ..............................................................10
4.2 Indoor Location .................................................................10
4.3 Location for the Optional ProLink™
Remote Monitoring System ..............................................11
5.0 General Electrical Safety Instructions ..........................12
6.0 Power Requirements ......................................................13
7.0 Electrical Wiring Instructions ........................................15
8.0 Spa Fill Up Procedure ....................................................20
9.0 Control Functions ...........................................................25
9.1 Control Panel ....................................................................25
9.2 General Spa Features And Controls .................................26
10.0 Operating Instructions ...................................................27
10.1 Register Your New Spa ....................................................27
10.2 Completing Your Registration ...........................................28
10.3 Setting Water Temperature ...............................................28
10.4 Activate Jet Pumps ...........................................................29
10.5 Light On/Off Button ...........................................................29
10.6 Light Mode Button .............................................................29
10.7 Jets ...................................................................................30
10.8 Selecting Desired Massage Action ...................................30
10.9 Waterfall Feature ..............................................................30
10.10 CLEAR RAY on Demand ...................................................30
10.11 Air Controls .......................................................................31
10.12 Optional BLUEWAVE® Spa Stereo System .....................31
10.13. Blow-Out Cycle .................................................................31
10.14 Cleanup Cycle ..................................................................31
©Jacuzzi Hot Tubs. All Rights Reserved
J-300
11.0 Menu Features and Programming Instructions ...........32
11.1 Primary Filtration Menu .....................................................32
11.2 Secondary Filtration Menu ................................................33
11.3 Programming the Heating Mode .......................................34
11.4 Programming the Change Filter Timer .............................35
11.5 Programming the CLEAR RAY Timer ................................35
11.6 Programming the Water Refresh Timer ............................36
11.7 Programming the Time .....................................................36
11.8 Programming the Date ......................................................37
11.9 Programming the Temperature Format ............................37
11.10 Programming the Language .............................................37
11.11 Programming the Lock Feature ........................................38
11.12 Resetting the Wi-Fi Connection (optional feature) ............38
12.0 Spa Maintenance ............................................................39
12.1 Cleaning The Filters ..........................................................39
12.2 Draining and Refilling ........................................................42
12.3 Pillow Care ........................................................................43
12.4 Cleaning The Spa Interior .................................................43
12.5 Cover Care and Maintenance ...........................................43
12.6 Tool Free Access Door .....................................................44
12.7 Maintaining The Synthetic Cabinet ...................................45
12.8 Winterizing ........................................................................45
12.9 Restarting Your Spa in Cold Weather ...............................46
13.0 Water Quality Maintenance ............................................46
13.1 pH Control .........................................................................47
13.2 Sanitizing ..........................................................................47
13.3 CLEAR RAY® (Ultraviolet) Water Purification System ......48
13.4 CLEAR RAY® Bulb Replacement and
Quartz Tube Maintenance ................................................49
14.0 Error Conditions/Error Messages .................................51
14.1 Summer Logic ...................................................................51
14.2 Panel Displays COOL .......................................................51
14.3 Panel Displays ICE ...........................................................52
14.4 Panel Displays SN--1 ........................................................52
14.5 Panel Displays SN--2 ........................................................52
14.6 Panel Displays Change CLEAR RAY Bulb ........................52
14.7 Panel Displays Change Filter ...........................................52
14.8 Panel Displays Change Water ..........................................52
14.9 Panel Displays FL--1 ........................................................53
14.10 Panel Displays FL--2 ........................................................53
14.11 Panel Displays OH ............................................................53
14.12 Panel Displays (-- -- -- --) ..................................................53
J-300
15.0 Troubleshooting Procedures .........................................54
15.1 FL--1 and FL--2 .................................................................54
15.2 None of the Components Operate (e.g. Pump, Light) ......54
15.3 Pump Does Not Operate ..................................................54
15.4 Poor Jet Action .................................................................55
15.5 Water is Too Hot ...............................................................55
15.6 No Heat .............................................................................55
16.0 Circuit Board Diagrams ..................................................56
16.1 North American J-335, J-345, J-355, J-365,
J-375 and J-385 Dedicated Power Models (60 Hz) ..........56
16.2 North American J-315 and J-325 Convertible Power
Models (For a 3-wire 120V 60 Hz connection) .................57
16.3 North American J-315 and J-325 Convertible Power
Models (For a 4-wire 240V 60 Hz connection) .................58
16.4 Export J-335, J-345, J-355, J-365, J-375 and
J-385 Models (50 Hz) .......................................................59
16.5 Export J-315 and J-325 Models (50 Hz) ...........................60
17.0 Dip Switch Settings and Wiring .....................................61
17.1 Switch settings for Domestic 60Hz Models .......................61
17.2 Switch settings for Export 50Hz Models ...........................62
17.3 Single Service 50Hz Connection ......................................64
17.4 Dual Service 50Hz Connection .........................................64
17.5 Three Service 50Hz Connection .......................................65
18.0 Optional BLUEWAVE® Spa Stereo System ..................66
18.1 Pairing the Remote and Stereo ........................................67
18.2 Audio Settings ...................................................................67
18.3 Wireless Remote Control Functions .................................69
18.4 Electronic Device Connections and Functions .................70
18.5 Wireless Remote Battery Replacement Procedure ..........72
18.6 BLUEWAVE® Spa Stereo System Specifications ............73
18.7 Stereo Cautions ................................................................73
J-300
J-300
1.0 Important Spa Owner Information
Your Jacuzzi J-300 Collection spa is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the spa for efficient operation, an uncovered spa surface and wall fittings directly exposed to sunlight and high temperatures for an extended period are subject to permanent damage. Damage caused by exposing the spa to this abuse is not covered under warranty. We recommend that you always keep the spa full of water when it is exposed to direct sunlight and that you keep the Jacuzzi premium insulating cover in place at all times when the spa is not in use. Read and carefully follow the requirements for your spa’s support base found in Section 4.0 titled,
“Choosing A Location” (page 9).
Jacuzzi constantly strives to offer the finest spas available, therefore modifications and enhancements may be made which affect the specifications, illustrations and/or instructions contained herein.
2.0 FCC Notice
This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Rearrange or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from the circuit connected.
4. Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate this equipment.
1
J-300
3.0 Important Safety Instructions for all Spa Owners
READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY!
This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB
Safety Act). When installing and using this spa, basic safety precautions should always be followed, including:
1.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
• Extreme caution must be exercised to prevent unauthorized access by children.
• To avoid accidents, ensure that children do not use this spa unless supervised at all times. Adult supervision is a critical safety factor in preventing children from drowning.
• Use the straps and clip tie downs to secure the spa cover when not in use. This will help discourage unsupervised children from entering the spa. Keep the spa cover secure in high-wind conditions.
• There is no representation that the cover, clip tie-downs, or actual locks will prevent access to the spa.
2.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
• Keep hair, loose articles of clothing or hanging jewelry away from suction fittings, rotating jets or other moving components to avoid entrapment that could lead to drowning or severe injury.
• Never use the spa unless all suction guards, filter, filter lid, or skimmer assembly are installed to prevent body and/or hair entrapment.
• Never operate or use the spa if the filter, filter lid, or skimmer assembly are broken or any part of the skimmer assembly is missing.
Please contact your dealer or nearest service center for service.
• The suction fittings and suction covers in this spa are sized to match the specific water flow created by the pump(s). If it is necessary to replace the suction fittings, suction covers or pump(s), be sure that the flow rates are compatible and are in compliance with the VGB
Safety Act.
• Never replace a suction fitting or suction cover with one rated less than the flow rate marked on the original suction fitting. Using improper suction fittings or suction covers can create a body or hair suction entrapment hazard that may lead to drowning or severe injury.
3.
!
DANGER:
RISK OF SEVERE INJURY FROM ELECTRIC
SHOCK OR DEATH FROM ELECTROCUTION!
• Install the spa at least 5 feet (1.5m), from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected (bonded) by a minimum No. 8 AWG (8.4 mm²) solid copper conductor attached to the wire connector on the grounding lug, inside the equipment compartment on the equipment box.
2
J-300
• A grounding wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.
• Never permit any electrical appliance, such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a spa unless such appliances are built-in by the manufacturer.
• Never bring any electrical appliances into or near the spa.
• Never operate any electrical appliances from inside the spa or when you are wet.
• The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with section 422-20 of the National Electrical Code/USA,
ANSI/NFPA 70. The disconnecting means must be readily accessible and visible to the spa occupant but installed at least 5 feet (1.5m), from the spa.
• The electrical circuit supplied for the hot tub must include a suitable ground fault circuit interrupter (GFCI) as required by NEC Article
680-42.
4.
!
WARNING: RISK OF SEVERE INJURY OR DEATH!
• Extreme caution must be exercised to prevent diving or jumping into the spa or slipping and falling, which could result in unconsciousness, drowning, or serious injury. Remember that wet surfaces can be very slippery.
• Never stand, walk or sit on the top railing of the spa.
5.
!
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, WELTS OR DEATH!
• Water temperature in excess of 104°F (40°C) may be injurious to your health.
• Refer to Section 3.2 Hyperthermia for specific causes and symptoms of this condition.
• The water in the spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.
• Lower water temperatures are recommended for young children
(children are especially sensitive to hot water) and when spa use may exceed 10 minutes.
• The Consumer Products Safety Commission/USA has stated that the water temperature in a spa should not exceed 104°F (40°C).
• Always test the spa water temperature before entering the spa.
The user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices may vary as much as +/- 5°F (2°C).
3
J-300
6.
!
WARNING: RISK OF SEVERE INJURY OR DEATH!
• Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, if pregnant or possibly pregnant, consult your physician before using a spa.
• Pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
• Persons suffering from obesity or a medical history of heart disease, low or high blood pressure, circulatory system problems, diabetes, infectious diseases or immune deficiency syndromes should consult a physician before using a spa.
• If you experience breathing difficulties in association with using or operating your spa, discontinue use and consult your physician.
• Persons using medication should consult a physician before using a spa since some medication may induce drowsiness, while other medication may affect heart rate, blood pressure, and circulation.
• Persons suffering from any condition requiring medical treatment, the elderly, or infants should consult with a physician before using a spa.
• The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
7.
!
WARNING: RISK OF SEVERE INJURY OR DEATH!
• Prolonged immersion in a spa may be injurious to your health.
• Observe a reasonable time limit when using the spa. Exposures at higher temperatures can cause high body temperature (overheating). Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly result in drowning or serious injury.
• Never use a spa immediately following strenuous exercise. Enter and exit the spa slowly. Wet surfaces can be slippery.
8.
!
WARNING: TO DECREASE RISK OF INFECTION OR DIS-
EASE!
• To reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water chemistry within the parameters listed on the inside cover of this manual and consult with a licensed engineer regarding proper ventilation if installed indoors or in an enclosed area.
• People with infectious diseases should not use a spa to avoid water contamination, which could result in spreading infections to others.
• Always shower before and after using your spa. Maintain water chemistry in accordance with manufacturer’s instructions. Failure to do so may result in contracting a waterborne illness (e.g. an infection, bacteria or virus).
4
9.
J-300
!
WARNING: In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments that could be present in the air or water.
Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.
10.
CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE.
• Maintain water chemistry in accordance with manufacturer’s instructions.
• Proper chemical maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components.
11.
!
WARNING: RISK OF SEVERE INJURY OR DEATH! The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
12. NOTE: This spa is not intended nor designed to be used in a commercial or public application. The spa buyer shall determine whether there are any code restrictions on the use or installation of this spa since local code requirements vary from one locality to another.
Hot Tub Safety Literature
To ensure you have a safe and enjoyable hot tub experience, learn all you can about hot tub safety and emergency procedures.
Especially useful are the brochures listed below:
• Children Aren’t Waterproof
• Pool and Spa Emergency Procedures For Infants and
Children
• Layers of Protection
• The Sensible Way to Enjoy Your Spa or Hot Tub
The Association of Pool and Spa Professionals publishes these brochures. To acquire a brochure:
• Ask your hot tub dealer (they may have copies)
• Go to http://apsp.org
• Conduct your own search on the internet
• Write to the following address:
The Association of Pool and Spa Professionals
2111 Eisenhower Avenue
Alexandria VA 22314
703.838.0083
5
J-300
3.1 Entrapment Risk
The Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drain and/or suction fittings causing death, drowning, or serious injury (see diagram below). This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act”
(VGB Safety Act). Entrapment risk can be minimized if proper precautions are taken.
!
DANGER:
RISK OF PERSONAL INJURY OR DEATH!
Never operate the spa if a suction fitting, suction cover, filter, filter lid or skimmer assembly are broken, damaged or missing.
Filter, Filter Lid,
Skimmer Assembly (location and style vary by models)
Note: Suction covers must be replaced every 5 years.
1.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
Hair entrapment: May occur if hair is entangled, knotted or snagged in a drain suction or skimmer assembly. This has been reported in persons who when submerge themselves underwater, allowing hair to come close and/or within the reach of the suction fittings, suction covers or skimmer assembly.
• Keep hair away from suction fittings, suction covers, filter, filter lid or skimmer assembly.
• Children are at risk for hair entrapment if swimming under water.
• Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.
2.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
Limb entrapment: May occur when a limb becomes entrapped, inserted or sucked into a suction or outlet opening.
• Always keep suction fittings, suction covers, filter, filter lid or skimmer assembly in place when operating to avoid limb entrapment.
• Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.
6
Suction Fittings,
Suction Covers
(locations vary by models)
J-300
3.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
Body entrapment: May occur when part of the torso becomes entrapped, inserted or sucked into a suction or outlet opening.
• Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.
4.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
Evisceration (disembowelment) entrapment: May occur when the buttocks becomes entrapped, inserted or sucked into a suction or outlet opening.
• Never sit on suction fittings, suction covers, filter, filter lid or skimmer assembly.
• Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.
5.
!
DANGER:
RISK OF SEVERE INJURY OR DROWNING!
Mechanical entrapment: May occur when jewelry, swimsuit, or hair accessories become entangled, knotted or snagged in a drain suction or skimmer assembly.
• Never allow your jewelry, swimsuit, or hair accessories to come close to the suction fittings, suction covers or skimmer assembly.
• Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.
3.2 Hyperthermia
Prolonged immersion in hot water may induce hyperthermia (overheating). The use of alcohol or drugs can greatly increase the risk of fatal hyperthermia in spas. A description of the causes, symptoms, and effects of hyperthermia are as follows:
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F
(37°C). The symptoms of hyperthermia include drowsiness, lethargy
(fatigue), and an increase in the internal temperature of the body (feeling of being too hot). The effects of hyperthermia include:
• Unawareness of impending hazard;
• Failure to perceive heat;
• Failure to recognize the need to exit spa;
• Physical inability to exit spa;
• Fetal damage in pregnant women; and
• Unconsciousness and DANGER of drowning.
A Warning Sign is provided in your warranty packet. Please install at a location near your spa, where it is visible to users of the spa. For additional or replacement Warning Signs please contact your local
Jacuzzi dealer and reference item number #6530-082.
7
J-300
3.3 Important Additional CSA Safety Instructions (Canada Only)
When using this electrical equipment, basic safety precautions should always be followed, including the following:
1.
READ AND FOLLOW ALL INSTRUCTIONS.
2. A green colored terminal or a terminal marked G, Gr, Ground,
Grounding or the symbol* is located inside the supply terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors that supply this equipment (*IEC Publication
417, Symbol 5019).
3. At least two lugs marked “Bonding Lugs” are provided on the external surface or on the inside of the supply terminal box/ compartment. To reduce the risk of electric shock, connect the local common bonding grid in the area of the spa to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG
(10 mm²).
4. All field installed metal components such as rails, ladders, drains or other similar hardware within 10 feet (3m) of the spa shall be bonded to the equipment grounding buss with copper conductors not smaller than No. 6 AWG (10 mm 2 ).
5.
SAVE THESE INSTRUCTIONS.
3.4 General Electrical Safety Instructions
Your new Jacuzzi spa is equipped with a “state-of-the-art” equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this spa must be installed properly to ensure dependable usage. Please contact your local Jacuzzi dealer or local building department should you have any questions regarding your installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with a current collector system. A pressure wire connector is provided on the surface of the control box, located outside the equipment door (Figure
B, page 17) to permit connection of a bonding wire between this point
and any ground metal equipment, metal water pipe or conduit within 5 feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²) solid copper wire. This is a most important safety assurance feature.
Before installing your spa, check with your local building department to insure installation conforms to local building codes.
8
J-300
4.0 Choosing A Location
IMPORTANT: Because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is in place. If the spa is placed on a surface which does not meet these requirements, damage to the skirt and/or the spa shell may result.
Damage caused by improper support is not covered under warranty.
It is the responsibility of the spa owner to assure the integrity of the support over time. We recommend a poured, reinforced concrete slab with a minimum thickness of 4 inches (10 cm). Wood decking is also acceptable provided it is constructed so that it meets the requirements outlined above.
!
WARNING: For spas that are to rest on balconies, roofs or other platforms not specifically tied into main struc-
tural support, consult a professional Structural Engineer with experience in this type of application.
The spa must be installed in such a manner as to provide drainage away from it. Placing the spa in a depression without provisions for proper drainage could allow rain, overflow and other casual water to flood the equipment and create a wet condition in which it would sit in. For spas which will be recessed into a floor or deck, install so as to permit access to the equipment, either from above or below, for servicing. Make certain that there are no obstructions which would prevent removal of all side cabinet side panels and access to the jet components, especially on the side with the equipment bay.
CAUTION:
If the spa is indoors or located in an enclosed area, proper ventilation should be discussed with an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and air associated with chemical odors outdoors. When the spa is in use considerable amounts of
moisture will escape potentially causing mold and mildew. This can cause health risk. Over time, this can damage certain surfaces, surroundings, and equipment.
9
J-300
4.1 Outdoor Location
In selecting the ideal outdoor location for your spa, we suggest that you take into consideration:
• The proximity to changing area and shelter (especially in colder weather).
• The pathway to and from your spa (this should be free of debris so that dirt and leaves are not easily tracked into the spa).
• The closeness to trees and shrubbery (remember that leaves and birds could create extra work in keeping the spa clean).
• A sheltered environment (less wind and weather exposure can result in lowered operation and maintenance costs).
• The overall enhancement of your environment. It is preferable not to place the spa under an unguttered roof overhang since run-off water will shorten the life expectancy of the spa cover.
• For spas that are to rest on balconies, roofs or other platforms not specifically tied into main structural support, consult a professional
Structural Engineer with experience in this type of application.
• In the unlikely event that you should ever need to access or gain entry to any portion of the spa for servicing, it is highly recommended that you plan your outdoor installation to provide full access to the entire spa. Please take this into consideration when placing the spa in a deck or enclosed by a surrounding.
• Consider locating your spa away from any reflective surface or glass to prevent any damage to the synthetic skirt.
• Do not shim the spa. To ensure proper support the spa must sit flat on the intended foundation.
4.2 Indoor Location
For indoor installations many factors need to be considered before installing a spa indoors:
!
WARNING: In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments that could be present in the air or water. Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.
• Proper Foundation: Consult a Structural Engineer when considering a foundation that will adequately support the spa
the entire time it is in place. Proper support is critical especially if the spa is to rest on a second story or higher. For spas that are to rest on balconies, roofs or other platforms not specifically tied into the main structural support, you should consult a professional
Structural Engineer with experience in this type of application.
10
J-300
• Proper Drainage: It is extremely important to have in place
measures to sufficiently handle excessive water spillage. Be sure the flooring in which the spa rests on has adequate drainage and can handle the entire contents of the spa. Be sure to make provisions for ceilings and other structures that may be below the spas installation. Areas around your spa can become wet or moist so all flooring and subsequent furniture, walls and adjacent structures should be able to withstand or resist water and moisture.
• Proper Ventilation: Proper ventilation should be discussed with an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and air
associated with chemical odors outdoors. When the spa is in use considerable amounts of moisture will escape, potentially causing mold and mildew over time which can damage certain surfaces and/ or surroundings.
• Sufficient Access: In the unlikely event that you should ever need to access or gain entry to any portion of the spa for servicing, it is highly recommended that you plan your indoor installation to provide full access to the entire spa.
• Warranty: Damage caused by not following these guidelines or any improper installation not in accordance to local codes or authorities is not covered under the spas warranty. Please consult your local state or city building ordinances.
• Do not shim the spa. To ensure proper support the spa must sit flat on the intended foundation.
4.3 Location for the Optional ProLink™ Remote Monitoring
System
IMPORTANT! Choose an installation site with the front control panel side pointing towards your home’s Wi-Fi router.
CAUTION: You must make sure that the spa control panel side has a clear unobstructed line-of-site of the home Wi-Fi router. This action ensures maximum signal strength between the spa and your home’s
Wi-Fi router.
Verify your home router’s Wi-Fi strength at the proposed spa location.
Front control panel side of spa must point towards your home’s Wi-Fi router in your home as illustrated, Figure 4.3a. Stand near the proposed front control panel side of the spa with your cell phone, then login to the internet using your home Wi-Fi router signal (not 3G or 4G) and verify results as follows:
11
J-300
If the home Wi-Fi router signal is strong (3-4 bars) and Internet access is stable, the proposed installation site is a good choice.
If the home router’s Wi-Fi signal is weak and Internet access is slow or produces an error, the proposed installation site is not a good choice.
• It may be necessary to choose another spa installation site.
• Relocate your home Wi-Fi
Home WiFi
Router router closer to the spa.
• Install a “repeater” device in the room closest to the spa to boost the home’s router Wi-Fi signal at the proposed spa installation site.
Figure 4.3
5.0 General Electrical Safety Instructions
Your new Jacuzzi spa is equipped with a “state-of-the-art” equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this spa must be installed properly to insure dependable usage. Please contact your dealer or local building department should you have any questions regarding your installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with a current collector system. A pressure wire connector is provided on the surface of the control box, located outside the equipment door (Figure
B, page 17) to permit connection of a bonding wire between this point
and any ground metal equipment, metal water pipe or conduit within 5 feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²) solid copper wire. This is a most important safety assurance feature.
Before installing this spa, check with the local building department to insure installation conforms to local building codes.
120/240 Volt Convertible Models
A spa connected to a 120 VAC electrical service must be located close enough to a grounded, grounding-type electrical outlet so that the included 10 feet (3m) power cord can be plugged directly into it. DO NOT
USE AN EXTENSION CORD as this could cause damage to the spa’s equipment due to insufficient voltage. The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.
12
J-300
6.0 Power Requirements
Jacuzzi spas are designed to provide optimum performance and flexibility of use when connected to the maximum electrical service listed below. Minor circuit board modifications can be performed to allow your new spa to accept an electrical service other than the factory operation setting.
Note: Refer to pages 56-60 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
North American J-335, J-345, J-355, J-365, J-375 and J-385 Models
(60 Hz)
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:
240V/40A* 240V/50A** 240V/60A***
40A 50A 60A
3
60 Hz
26A
3
60 Hz
37A
3
60 Hz
48A pumps are running. This is the factory setting.
are running.
North American J-315 and J-325 Convertible Models (60 Hz)
Circuit Breaker:
Number of Wires:
120V/15A* 240V/30A* 240V/40A**
15A, 1-Pole 30A, 2-Pole 40A , 2-Pole
3 (15A GFCI
Cord US
Only*)
4 (Hard Wire
Only)
4 (Hard Wire
Only)
Frequency:
Current Draw:
60 Hz
12A
60 Hz
20A
60 Hz
31A
* In 15A/30A configuration, the heater will not operate while the jets pump is running. The factory setting is 120V/15A.
** In 40A configuration, the heater will operate while the jets pump is running.
**CAUTION: (For a 4-wire 240 VAC Heater Operation): Make
certain wires are connected exactly as shown in Figure D (page 18)
before applying power. Failure to do so will result in damage to the circuit board and/or related components and void the manufacturer's warranty.
13
J-300
Export Models (50 Hz) Service
Single Breaker
Service 1
(including Heater)*
230 VAC
Single Breaker
Service 1 (including
Heater)**
230 VAC Voltage:
Max. Current Draw:
1-Pump System
2-Pump System
15A
17A
22A
29A
Wattage:
1-Pump System:
2-Pump System:
Frequency:
Number of Wires:
3.5 kW
3.9 kW
50 Hz
3
5.1 kW
6.7 kW
50 Hz
3
Single Breaker is the factory default.
* For this service, the heater will not operate while either jets pump is running. The service 1 breaker will include connection for all components.
** For this service, the heater will operate while two jets pump are running.
The service 1 breaker will include connection for all components.
Export Models (50 Hz) Service
Dual Breaker
Service 1/
Service 2***
230 VAC
Three Phase Service
Service 1/
Service 2/Service 3***
230 VAC Voltage:
Max. Current Draw:
1-Pump System
2-Pump System
Wattage:
1-Pump System:
2-Pump System:
12A/10A
12A/17A
N/A
12A/10A/7A
2.8kW/2.3kW
2.8kW/3.9kW
N/A
2.8kW/2.3kW/1.6kW
Frequency: 50 Hz 50 Hz
Number of Wires: 5
Single Breaker is the factory default.
5
*** For this service, the heater will operate while two jets pump are running.
The service 1 breaker will include connections for the heater and transformer. The service 2 breaker is for all other components.
running. The service 1 breaker will include connections for the heater and transformer. Service 2 breaker is for pump 1 and other components.
Service 3 breaker is for pump 2.
14
J-300
7.0 Electrical Wiring Instructions
IMPORTANT NOTICE: The electrical wiring of this spa must meet the requirements of the National Electrical
Code/USA (NEC) and any applicable state or local codes.
The electrical circuit must be installed by a qualified electrician and approved by a local building/electrical inspection authority.
1. Convertible 120/240V Power Models:
•
!
DANGER:
TO DECREASE THE RISK OF SHOCK,
PRODUCT DAMAGE OR ELECTRICAL FIRE.
120V “Plug-in” Operation: This spa must operate on the supplied
10 foot (3m) GFCI cord at its original length or must be hard-wired for longer runs. NEVER USE AN EXTENSION CORD FOR ANY
REASON!
• Convertible 120/240V Operation: The included 120V GFCI cord must be discarded for 240V operation. This spa must be hard wired. Supplying power to either configuration above which is not in accordance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty.
2. Dedicated 240V models must be permanently connected (hard-
wired) to the power supply. No plug-in connections or extension cords are to be used in conjunction with the operation of this spa.
Supplying power to the spa which is not in accordance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty.
3. The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.
4. To determine the current, voltage and wire size required, refer to
Section 6.0 “Power Requirements” (page 13).
• Wire size must be appropriate per NEC/USA and/or local codes.
• We recommend type THHN wire.
• All wiring must be copper to ensure proper connections. Do not use aluminum wire.
5. When using wire larger than #6 (10 mm²), add a junction box near the spa and reduce to short lengths of #6 (10 mm²) wire to connect to the spa.
6. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422-20 of the National Electrical Code/USA,
ANSI/NFPA 70. The disconnecting means must be readily accessible to the spa’s occupant but installed at least 5 feet (1.5m) from spa water.
7. The electrical circuit supplied for the spa must include a suitable ground fault circuit interrupter (GFCI) as required by NEC/USA Article
680-42.
15
J-300
8. The electrical supply for this product must include a suitably rated isolating switch and circuit breaker to comply with local electrical regulations. This RCD/GFCI circuit breaker must be installed at the power supply in the house electrical box.
9. For Australia/New Zealand, the spa should be supplied through a residual current device (RCD) with a rated tripping current not exceeding 30mA (IEC 60335-2-60).
10. To gain access to the spa’s power terminal block, press the release button securing the synthetic cabinet panel under the control panel
(Figure A). Then remove the control box door screws and door
(Figure B).
11. Select the power supply inlet you want to use (Figure A). Make sure to install a 3/4" electrical fitting and conduit through the large opening provided in the side of the control box so you can feed the cable through to the terminal block.
12. Connect wires to terminal blocks TB1 and TB3 (Figure C, page
17). TIGHTEN SECURELY! All wires must be hooked up securely
or damage could result.
13. Install control box door and screws and reinstall the cabinet panels.
Figure A
Equipment Area
9
11
8
10
7
1
3
2 2
6 4 6
5
Note: Equipment location (such as pumps, CLEAR RAY system, drain, heater etc.) varies by model.
1. Control Box
2. Power Supply Entrance(s)
3. 1-Speed Jets Pump
4. Heater
5. Spa Drain Valve
6. Pump Drain Plugs(s)
7. 1-Speed Jets Pump
8. Circulation Pump
9. Control Panel
10. CLEAR RAY® (Ultraviolet) Water
Purification System
11. Optional ProLink™ Monitoring
System
16
Figure B Control Box
STEP LIGHT
(OPTIONAL)
J59 J51
TB3
J33
J41
J36
J47
J46
J38
J53
TB1
F3 0.125A 240V
2 3 1
1. Main Terminal
2. Bonding Lug/Grounding Terminal
3. Power wires entrance (electrical fitting and conduit must be installed)
J-300
Figure C Connections
(North American 60 Hz
240 VAC Connection Models)
STEP LIGHT
(OPTIONAL)
J59 J51
TB3
J33
J41
J36
J47
J46
J38
J53
TB1
F3 0.125A 240V
TB3
Green
J41
J36
J47
J46
TB1
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
Turn power off before servicing. This task should only be performed by a qualified technician.
17
J-300
TB3
Green
Figure D
(North American 60 Hz
STEP LIGHT
(OPTIONAL)
120/240 VAC Convertible Models)
J59 J51
TB3
J33
J41
J36
J47
J46
J38
J53
TB1
F3 0.125A 240V
J41
J36
J47
J46
J22 240V
OR
TB3
Green
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
J41
J36
J47
J38 Wht J22 240V
TB1
Turn power off before servicing. This task should only be performed by a qualified technician.
120 VAC 3-Wire connection 60 Hz 240 VAC 4-Wire connection 60 Hz
120V 3-WIRE CONNECTION
J37 J59 120V 120V
240V
J22
D
C
B
BLK
WHT
A
TB1 GRN
120V 120V
240V
J22
Jumper Wires
FROM TO
J37 J36
J51
J59
J33
J22
J46
J41
J47
2 jumpers
18
240V 4-WIRE CONNECTION
J37 J59 120V 120V
D
C
B
J22
240V
WHT
BLK
RED
A
TB1 GRN
120V 120V
240V
J22
FROM
J37
J51
Jumper Wires
TO
J38
J46
J59
J33
J22
J53
J47
1 jumper
CAUTION: (FOR A 4-WIRE 240 VAC HEATER OPERA-
TION.) The jumper at location J22 must be changed from a 120V to a 240V configuration. Make sure to connect the wires as shown at TB1, for a 240V connection, before applying power. Jumper wires MUST be changed. Failure to follow these steps will result in damage to the circuit board and/or related components and void the manufactures warranty.
J-300
Figure E
(Export 50 Hz
230 VAC Connection*)
TB3 TB1
Blu Brn
(N1) (L1)
Green
BREAKER TERMINAL
CONNECTIONS
L1 = Heater & Transformer
L2 = All other components
Service 1
Blu (N1)
Brn (L1)
Service 2
Brn (L2)
Blu (N2)
Service 1
Brn (L1)
Blu (N1)
BREAKER TERMINAL
CONNECTIONS
L1 = All components
Factory Default
TB3 TB1
Brn
Blu
(L2)
(N1) (L1)
Blu
Brn
(N2)
Green
TB3 TB1
Green
Brn
(L2)
Blu
(N1)
Brn
Brn
(L1)
(L3)
Service 1
Blu (N1)
Brn (L1)
Service 2
Brn (L2)
Service 3
Brn (L3)
BREAKER TERMINAL
CONNECTIONS
L1 = Heater & Transformer
L2 = Pump 1 and other components
L3 = Pump 2
19
J-300
8.0 Spa Fill Up Procedure
For best results, read each step in its entirety before proceeding with that
step. Make sure all drains are closed before you begin, page 16.
1. Prepare The Spa For Filling
• Clear all debris from the spa. (Although the spa shell has been polished at the factory, you may want to treat it with a specially formulated spa cleaner.) Consult your authorized Jacuzzi dealer for additional information prior to filling spa.
• Remove filter cover, then remove filter cartridge as outlined in
2. Fill Spa
• Place the end of your garden hose into the empty filter fitting.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is extremely
“hard,” it is preferable to fill half-way with hard water and the rest of the way with softened water. Water that is too soft can be corrosive to metal components.
•
!
WARNING: TO DECREASE RISK OF INFECTION OR
DISEASE.
Fill hot tub with clean tap water from garden hose, to reduce risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments. Fill until water covers all jets but does not touch the bottom of the lowest headrest. (DO NOT OVERFILL!)
IMPORTANT: Always fill your spa through the filter fitting after draining. Failure to do so may cause air to be trapped the pumps, preventing the pumps from circulating water. Remove the hose and replace the filter cartridge. Note: DO NOT overtighten filter cartridge, finger tight only!
3. Turn On Power
Turn on power to spa at the home’s circuit breaker to start boot up
sequence (Sec. 10.0, page 27). The heater and filter pump will
automatically activate after several seconds. If the control panel LCD
displays “COOL” or “ICE” this is normal, refer to page 51 for additional
information.
4. Activate Jets Pumps
Turn on jets pump(s) to ensure proper mixing when adding start-up chemicals in step 5.
1
2
20
J-300
5. Add Start-Up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See “Water Quality Maintenance” (page 46) for general
guidance.
!
WARNING: RISK OF POISONING OR DEATH.
Never leave chemicals opened and accessible to anyone. Use chemicals according to the vendors instructions. Always store chemicals in a safe and/or locked location. Keep away from and out of reach of children.
6. Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading of no less than 1.0 ppm free chlorine or 2.0 ppm bromine. To ensure healthy water conditions, always maintain a constant sanitizer reading within the levels recommended on the inside cover of this manual. If sanitizer levels cannot be stabilized, perform the decontamination procedure steps 9-15 on the following page.
Note: The “decontamination procedure” steps 9-16 should also be used
after the spa has been “Winterized” (page 45) or has been sitting with-
out power for an extended period.
7. Set Spa To Heat
To warm spa water to a comfortable temperature, follow these steps:
• The LCD display on the control panel displays the actual temperature of the spa water. Press either the COOLER ( ) or
WARMER ( ) button once to display the “set” temperature for 5 seconds. If you want the water to heat to a different temperature, simply press COOLER ( ) or WARMER ( ) within 5 seconds.
The set temperature increases or decreases by one degree each time one of these buttons is pressed.
• The heater will turn off when the temperature corresponding to the thermostat setting is achieved.
• To access the overtemp feature refer to Section 10.3, page 28.
Important Heater Details:
• The maximum water temperature setting for your spa is 104°F
(40°C) and the minimum setting is 65°F (18°C).
• For North American spas connected to a 40 amp service, jets pump
#1 and jets pump #2 must be turned off to operate the heater.
• For Export spas connected to a 20 amp service, jets pump #1 and jets pump #2 must be turned off to operate the heater.
• Setting the thermostat at maximum will not accelerate the heating process. This will only result in a higher ultimate temperature.
• The heater operates until the water reaches the programmed “set temperature,” then turns off. The heater will reactivate after the water cools to approximately 2° below the set temperature.
21
J-300
8. Place Cover On Spa
• Keeping the insulating cover in place anytime the spa is not in use will reduce the time required for heating, thereby minimizing operating costs.
• The time required for initial heat-up will vary depending on the starting water temperature.
!
DANGER:
RISK OF PERSONAL INJURY.
Check water temperature carefully before entering hot tub!
Excessive water temperature can cause burns, welts and body temperature to rise, hyperthermia (over-heating).
Decontamination Procedure (Steps 9-16)
Steps 9-16 below are only required when sanitizer levels are unstable after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer levels remain stable after performing steps 1-6 above (refer to the inside cover of the manual).
9. Add 2.5 ounces (71 g) of sodium dichlor for every 100 gallons (378
Liters) of water. Refer to the table below for approximate water fill volume by model.
!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemicals may damage components within your hot tub, burn or irritate your skin, create a rash, and void the manufacturer warranty for your spa.
Water Fill Volume by Model
Spa Model Average Fill Volume*
J-385 500 Gal (1,893 L)
J-375
J-365
470 Gal (1,779 L)
440 Gal (1,666 L)
J-355
J-345
J-335
J-325
400 Gal (1,514 L)
370 Gal (1,401 L)
360 Gal (1,363 L)
360 Gal (1,363 L)
J-315 230 Gal (871 L)
*Use average fill volume for chemical maintenance
Sodium Dichlor
12.5 oz
11.75 oz
11.0 oz
10.0 oz
9.25 oz
9.0 oz
9.0 oz
5.75 oz
22
J-300
10. Leave spa cover open during this step to allow excessive chemical vapors to exit spa, protecting pillows and plastic knobs from chemical attack. If spa is indoors, open doors and windows for proper ventilation. Turn on all jet pumps for one hour, then place the massage selector knob in the center “combo” position and open all air controls.
Note: You will need to press the jets pump button(s) every 20 minutes since these functions have an automatic 20 minute time-out function that turns them off.
!
WARNING: RISK OF PERSONAL INJURY!
• To decrease the risk of injury, drowning or entrapment, never leave your hot tub unattended for any reason while the cover is open and accessible, especially to small children and animals!
• Precautions should be taken to minimize your exposure to chemical vapors (that could cause lung, brain, or skin damage).
11. Turn off power to the spa at the circuit breaker, then drain spa as
outlined in “Draining and Refilling” (page 42).
12. Fill spa until water covers all jets but does not touch the bottom of the lowest headrest. DO NOT OVERFILL.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is extremely
“hard,” it is preferable to fill half-way with hard water and the rest of the way with softened water. Water that is too soft can be corrosive to metal components.
13. Consult your authorized Jacuzzi dealer for chemical recommendations, then add chemicals to hot tub water to achieve a constant sanitizer reading within the levels recommended on the inside cover of this manual.
14. Turn on all jets pump(s) when adding chemicals to ensure proper mixing and leave your hot tub cover open until the sanitizer level becomes stable to protect pillows and plastic knobs from chemical attack. Refer to the inside cover of the manual.
23
J-300
!
WARNING: RISK OF PERSONAL INJURY.
• To decrease the risk of injury, entrapment or drowning, never leave your hot tub unattended for any reason, especially if while the cover is open and accessible to small children and animals!
• To decrease the risk of contracting a waterborne illness
(e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water chemistry within 6 step parameters.
If you or other bathers experience such a condition, discontinue use and seek immediate medical attention.
15. Establish a sanitizer reading no less than 1.0 ppm free chlorine or 2.0 ppm bromine, then allow the hot tub to set undisturbed for
8 hours. Retest water after 8 hours to determine if sanitizer levels are stable. If sanitizer levels are stable, your spa is ready for use.
To ensure healthy water conditions, always maintain a constant sanitizer reading within the levels recommended on the inside cover of this manual. If sanitizer levels are not stable at this time, it will be necessary to repeat this procedure in its entirety (steps 1-15) until stable sanitizer readings are achieved.
IMPORTANT: If the CLEARRAY® water purification system is removed from the hot tub or is not operating effectively follow the “without CLEAR-
RAY” water chemistry parameters as defined by the Association of Pool and Spa Professionals.
16. After adequate sanitizer levels are achieved, close all spa air controls to maximize heat retention when spa is not in use.
24
J-300
9.0 Control Functions
9.1 Control Panel
A. CLEAR RAY ( )Button:
Manually activates the
CLEAR RAY system for a onehour period.
C
B
D
A
E
J
F
2-Pump Control Panel Shown
I
1
G
2
H
B. CLEAR RAY Indicator: Lit when the CLEARRAY is on.
C. Light On/Off ( ) Button Options: Turns waterfall light, footwell light, lighted cup holders and backlit pillows on in unison. Press once for high intensity; press a second time for medium intensity; press a third time for low intensity; press a fourth time to turn off. The displayed color is changed using the light mode button (D) below.
D. Light Mode ( ) Button: Selects one of 4 light color modes for waterfall, footwell, cup holders, and pillow lights. See page 29 for additional information.
E. Cooler ( ) Button: Decreases water temperature set point. Also used to navigate through the programming menus.
F. Warmer ( ) Button: Increases water temperature set point. Also used to navigate through the programming menus.
G. Jets 1 (
1
) Button: Turns jets pump #1 on and off.
H. Jets 2 ( off.
2
) Button (J-335 to J-385): Turns jets pump #2 on and
I. Menu ( ) Button: Allows access to the programming menus.
J. LCD Display: Can display current water temperature (default display), water temperature set point, selected menu functions, and error messages.
Operation Details
• Temperature Adjustment: 65 to 104°F (18 to 40°C). Factory default setting is 100°F (38°C).
• CLEAR RAY Operation: System runs for 1 hour (when manually activated), then automatically shuts off.
• Light Operation: All LED lights run for 2 hours, then automatically shut off.
• Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when activated, then turn off automatically to conserve energy. Simply press either jets button to continue operation for an additional 20 minutes.
25
J-300
9.2 General Spa Features And Controls
4 16
2
7
2
4
21 21
17
16
15
13
14
18
15
5 11
6
16
8
16
16
14
8
19
15
19
8
18
3
19 19
6
10
9
5
5
15
4
13
12
4
15
21 21
17
2 2
20
1
1. Control Panel
2. Toggle Air Controls
3. Filter/Skimmer Grill
4. Backlit Pillows
5. Lighted Cup Holders*
*Light features not offered on J-315/J-325 Models.
6. Massage Selector Valves
7. Waterfall Feature
8. Footwell Suction Fittings
9. Spa Light
10. Heater Return Fitting
11. Waterfall overflow
J-385 model illustrated - Location of features varies by model. Specifications/features subject to change without notice.
12. PowerPro MX2 Jets
13. PowerPro FX Large Rotational Jets
14. PowerPro FX Large Jets
15. PowerPro FX Jets
16. PowerPro FX Rotational Jets
17. PowerPro NX2 Jets
18. PowerPro BX Jets
19. PowerPro Mini FX Jets
20. Optional BLUEWAVE® Spa
Stereo System
21. Optional Stereo System
Speakers
Specifications Subject to Change Without Notice.
26
J-300
10.0 Operating Instructions
The spa control system has automatic functions that operate upon start-up and normal operation to protect the system. Upon the first power up, the readout displays the following information:
1. Control panel displays all lit indicators, permitting visual inspection of all display segments and indicator lights for proper operation.
2. Control panel displays the controller and control panel software versions.
3. Control panel scrolls the message, “ WELCOME TO JACUZZI.”
4. Control panel scrolls the message, “ PLEASE REGISTER YOUR
SPA AT WWW_JACUZZI_COM.”
Note: It is common for the heater to turn on after the spa is first filled because tap water is often very cold. If water temperature, at this time, is less than the factory default temperature setting of 100°F (38°C) the heater will turn on and run until the water temperature rises to the factory setting, then turn off.
10.1 Register Your New Spa
Registering your spa is important in order to validate your warranty. To register you will need to have the spa serial number, Figure 10.1, then you will need to register online in order to receive a passcode (not applicable to export models). A passcode is only given for North American models only.
The passcode must be entered on the control panel in order to unlock the registration lockout.
If this option is skipped (North American models only), you will be able to activate components, but, after 10 minutes, the screen will revert back to the registration screen. This process will continue until the spa is registered and the passcode is entered.
Note: The spa will still protect itself if an error is detected.
To register your spa you need to have your spa serial number. The best time to retrieve the serial number is when the spa is being connected. You must register your spa via the internet at www.Jacuzzi.com.
Follow these steps to register your spa.
Serial
Nameplate
1. Using your home computer or other device, connect to
Figure 10.1
the internet.
2. Go to www.Jacuzzi.com website to register your spa.
Outdoor Hot Tubs
4. Click For Owners
Warranty and Manuals
6. Click Warranty Registration
7. Enter your serial number.
8. Once registered, you will be given a passcode that will need to be entered into the control panel, North American models only, (Section
27
J-300
Keep a record of your serial number and passcode for any future reference. Write that information below.
Serial Number:
Passcode:
10.2 Completing Your Registration
Once the spa is registered online, you will continue the process at the spa control panel. You will need to enter the serial number and passcode given when you registered online. Follow the steps below.
Note: The control panel does not have a back button. If an incorrect number is entered you must complete the entire registration steps. At that point, the system will return an “INCORRECT PASSCODE” message.
A. Entering the Serial Number and Passcode
1. Press until you get to the “S\N” Menu. The display will scroll
“SET SERIAL NUMBER.”
Note: Once a valid serial number and passcode have been entered, this screen will not appear again.
2. Press
1
to prepare the system.
3. Enter the serial number. Using the or buttons you can cycle through the numbers 0 to 9. If your serial number begins with a letter, use the or buttons until the letter is displayed.
4. Once you reach a desired number release the button. Press
1
after selecting each of the numbers and allow the cursor to move to the next selection. After the last number is saved, proceed to enter the passcode (not applicable to export models).
6. Using or you can cycle through the numbers 0 to 9.
7. Once you reach a desired number release the button. Press
1
after selecting each of the numbers and allow the cursor to move to the next selection.
8. If the passcode is correct, the display will scroll “PASSCODE
ACCEPTED.” If there was error, the display will scroll “INCORRECT
PASSCODE.” You will need to re-enter the passcode.
10.3 Setting Water Temperature
Press (or press and hold) either or to adjust the current temperature setting. Once the desired temperature is reached, do not press any buttons on the control panel for about 3 seconds. The new temperature setting will saved. When the spa is heating the heat icon will be displayed.
To access the overtemp feature that allows the spa to reach 106°F
(41°C) continue to the next steps.
!
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, WELTS OR DEATH!
Water temperature in excess of 104°F (40°C) may be injurious to your health.
28
J-300
1. Press and hold then;
2. Press and hold the
1
at the same time for 2 seconds. You will see the temperature change to 105°F (40.5°C)
1 2 on the LCD display. Press to raise the temperature to 106°F (41°C) To Figure 10.3a
lower the temperature, press .
3. When the overtemp has been activated, the asterisk after the last digit will appear as an indicator for being in the overtemp mode,
Figure 10.3a.
Note: Once the temperature goes below 104°F (40°C) and you would like to raise the temperature to 106°F (41°C) again, you will have to repeat the steps.
10.4 Activate Jet Pumps
The JETS 1 (
1
) button activates jets pump 1. The first press turns jets pump 1 on; the second press turns jets pump 1 off.
The JETS 2 (
1
2
) button activates jets pump 2 (if equipped).
The first press turns jets pump 2 on; the second press turns
2 jets pump 2 off. When manually activated, either pump will automatically turn off after 20 minutes.
10.5 Light On/Off Button
Pressing this button activates the waterfall light, footwell light, lighted cup holders, and backlit pillows lights in unison as follows: high - medium - low - off.
Note: Lights automatically turn off after 2 hours.
10.6 Light Mode Button
This button offers 4 light modes for your enjoyment. Press this button to select your favorite lighting effect as follows:
1st press
2nd press
3rd press
4th press
5th press
6th press
7th press
8th press
9th press
10th press
11th press high speed blend mode low speed blend mode freezes low speed blend mode solid Blue color solid Violet color solid Red color solid Amber color solid Green color solid Aqua color solid Near White color goes back to high speed blend mode
29
J-300
10.7 Jets
The water flow through individual jets in your spa can be adjusted or turned off by rotating the outside jet ring. Some jets offer an adjustable center nozzle that allows you to change the water discharge angle. Simply tilt the center nozzle in these jets to the desired angle to customize your personal massage. Other jets offer a spiral action that produces a surging stream of air and water that provides a vigorous massage.
Note: Always keep at least 6 adjustable jets open at all times to ensure proper filtration characteristics within the spa.
10.8 Selecting Desired Massage Action
All models incorporate a massage selector valve that allows you to customize the massage and performance by diverting water between various jet systems within the spa. Simply turn
B
A
C valve to positions A, B or C to divert water pressure to various jet groups.
Note: The valve is intended to operate in positions A (Combo), B, or C for optimum performance. It is considered normal for sound levels within the valve to increase between these positions due to the large amounts of water flowing through it. For optimum filtration benefits, always leave this valve in position A when the spa is covered and select positions B or
C for maximum jet performance during spa use.
10.9 Waterfall Feature
The waterfall feature allows you to independently control it for a customized soothing effect.
For J335-J385
The waterfall is on when the circulation pump is on. The JETS 1 (
1
) or
CLEAR RAY ( ) buttons will also activate the waterfall feature.
For J315 and J325
The waterfall is on when the jets pump 1 is on.
Waterfall Operation Details:
A. Push thumb wheel on top of waterfall to the left (while in spa) to start or increase flow.
B. Push thumb wheel on top of waterfall to the right (while in spa) to slow or turn flow off.
Note: When the waterfall is in the OFF position, some water may still flow through. This is considered normal.
10.10 CLEARRAY on Demand
The CLEAR RAY on demand feature activates the water purification system for a period of 1-hour. Press the button to turn the system on. During this time the circulation pump and the CLEAR RAY unit are on.
Note: When the CLEARRAY system is on, due to a programmed or scheduled setting, the feature cannot be turned off.
30
J-300
10.11 Air Controls
Certain jet systems have their own “toggle” on/off air control.
Each control introduces air into the water lines that supply specific jet groups. Simply press any air control button
Jacuzzi logo side down to open or press the opposite side of button to close.
Note: To minimize heat loss, close all air controls (Jacuzzi logo up) when spa is not in use. Certain jets may draw air even though they are closed.
This is considered normal.
10.12 Optional BLUEWAVE® Spa Stereo System
Spas equipped with the optional audio system offer enhanced enjoyment. These models include a high-quality FM/USB/AUX/Bluetooth® stereo receiver with four high-quality marine speakers for unsurpassed sound quality and long-life.
Note: Digital rights management (DRM) files cannot be played. Personal files (MP3, WMA, iTunes or AAC) can be played as long as they are not
DRM encrypted files.
AUDIO MODE
1
DIR -
2 3
REPEAT DIR + RANDOM
10.13. Blow-Out Cycle
This cycle will purge the air from the plumbing lines normally caused by draining and filling the spa. The Jets Pump 1 and the Circulation Pump will turn on for 1 minute and then shut off. Then Jets Pump 2 will turn on and run for 1 minute then shut off. This cycle will only occur at start up.
Note: Turning off the corresponding jets pump that is running can deactivate the feature.
10.14 Cleanup Cycle
The cleanup cycle occurs once per day at 12:00 PM (noon) for 2 minutes. This is not user programmable. The Jets Pump 1 and the
Circulation Pump will turn on for one minute and then shut off. Then Jets
Pump 2 will turn on and run for 1 minute then shut off.
Note: Turning off the corresponding jets pump that is running can deactivate the feature.
31
J-300
11.0 Menu Features and Programming Instructions
Your spa is equipped with menus that allow you to program additional features. By continually pressing the Menu ( ) button you will cycle through the menus as follows (Figure 1):
Current temperature (Main Menu)
Secondary Filtration (page 33)
Figure 1
11.1 Primary Filtration Menu
During the primary filtration cycle, the circulation pump and CLEAR RAY are activated. The spa is programmed with a default setting starting at
12:00 AM and lasting for 8 hours, but this can be changed. This cycle allows the circulation pump to run for a preset amount of time per day, in addition to the normal operation.
Note: Any time the circulation pump runs outside of a program cycle, e.g. for heating, that run time will be deducted from the next primary filter cycle. For example, the primary filter cycle is set to 8 hours every 24 hours but the circulation pump comes on for 2 hours to heat the water after the cycle has finished. The next primary filter cycle will only be for 6 hours not 8 hours.
32
J-300
A. Programming the Primary Filtration Cycle
To change the programmed Primary Filtration Cycle:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ PF” Menu. The display will scroll
“ PRIMARY FILTER.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to display the current start time and prepare the system for changes.
3. Press or to adjust the start time, in 1-hour increments. To switch from “AM” to “PM” you must round a 12-hour period.
4. Press
1
to confirm and save the start time.
5. Press or to adjust the duration of cycle, in 1-hour increments.
6. Press
1
to confirm and save the duration time. The system will return to the “ PRIMARY FILTER” Menu.
In extreme bitter cold weather, where freezing can occur, we recommend you program the primary filtration cycle to run 24
hours. Refer to the “Winterizing” section on page 45.
11.2 Secondary Filtration Menu
The jets pump 1 activates during the secondary filtration to provide additional skimming. The spa is programmed with a default setting of
Holiday Mode, but can be programmed to other modes. There are 3 different modes, Holiday, Light and Heavy Mode.
Note: During the secondary filtration the jets pump 1, circulation pump and CLEAR RAY are activated.
• Holiday Mode disables the Secondary Filtration.
• Light Mode will activate two 10-minute cycles every other day; one at 8:00 AM and the other at 8:00 PM.
• Heavy Mode will activate two 10-minute cycles every day; one at 8:00 AM and the other at 8:00 PM.
A. Programming the Secondary Filtration Cycle
To change the programmed Secondary Filtration Cycle:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ SF” Menu. The display will scroll
“ SECONDARY FILTER.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to enter the Secondary Filtration programming.
Continually press to scroll through the following modes:
• Holiday Mode: The screen will display “HOL” and scroll
“HOLIDAY MODE.”
33
J-300
• Light Mode: The screen will display “LT” and scroll “LIGHT
MODE.”
• Heavy Mode: The screen will display “HVY” and scroll “HEAVY
MODE.”
3. Once a selection is made, press
1
to confirm and activate the setting. The system will return to the “ SECONDARY FILTER” Menu.
11.3 Programming the Heating Mode
Your Jacuzzi spa is equipped with 3 modes of heating. An automatic mode called “AUTO,” where the spa’s temperature is maintained at all times. An energy saving heating cycle called “ECO.” A mode that will only activate the heater during the daytime called “DAY” mode.
Note: The heater will activate when the temperature drops 2° from the set temperature.
• Economy Mode is an energy savings program. The spa is allowed to heat between 5:00 PM and 7:00 AM every day. The hours are not programmable.
• Day Mode allows the spa to heat during the day, between 7:00
AM to 5:00 PM. The hours are not programmable.
• Auto Mode allows the heater to heat, at all times, in order to maintain the preset temperature.
A. Programming the Heating Mode
To change the programmed heating mode:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ HEAT” Menu. The display will scroll
“ HEATER MODE.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to prepare the system for changes. Continually press to scroll through the following modes:
• Economy Mode: The screen will display “ECO” and scroll
“ECONOMY MODE.”
• Day Mode: The screen will display “DAY” and scroll “DAY
MODE.”
• Auto Mode: The screen will display “AUTO” and scroll “AUTO
MODE.”
3. Once a selection is made, press
1
to confirm and activate the setting. The system will return to the “ HEATER MODE” Menu.
34
J-300
11.4 Programming the Change Filter Timer
A programmable filter timer can be set to remind you when to clean or replace the filters.
• The default setting is for 180 days.
• The timer range is from OFF to 180 days, in increments of 10 days.
Note: It is not recommended that this feature be turned OFF. In order to continually maintain clean and working filters, it should be program as instructed.
A. Programming or resetting the timer.
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ FC” Menu. The display will scroll
“ FILTER CHANGE.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to prepare the system for changes. Continually press to adjust the length of time for the timer.
3. Once you select the number of days, press
1
to confirm this selection. The system will return to the “ FILTER CHANGE” Menu.
4. Once the timer expires the display will alternate between the water temperature and “
11.5 Programming the CLEARRAY Timer
A programmable change bulb timer can be set to remind you when to when it is time to replace the UV bulb for the CLEAR RAY system.
• The default setting is for 365 days.
• The timer range is from OFF to 365 days, in increments of 10 days.
Note: It is not recommended that this feature be turned OFF. In order to continually have the CLEAR RAY system effectively preform its function, it should be program as instructed.
A. Programming or resetting the timer.
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ UV” Menu. The display will scroll
“ CLEARRAY BULB.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to prepare the system for changes. Continually press to adjust the length of time for the timer.
3. Once you select the number of days, press
1
to confirm this selection. The system will return to the “ CLEARRAY BULB” Menu.
4. Once the timer expires the display will alternate between the water temperature and “
CHANGE CLEARRAY BULB” page 52.
35
J-300
11.6 Programming the Water Refresh Timer
A programmable water refresh timer can be set to remind you when to when it is time to drain and refill your spa.
• The default setting is for 180 days.
• The timer range is from OFF to 180 days, in increments of 30 days.
Note: It is not recommended that this feature be turned OFF. In order to continually maintain the water healthy and clean, in addition to chemical maintenance, it should be program as instructed.
A. Programming or resetting the timer.
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ H2O” Menu. The display will scroll
“ WATER REFRESH.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to prepare the system for changes. Continually press to adjust the length of time for the timer.
3. Once you select the number of days, press
1
to confirm this selection. The system will return to the “ WATER REFRESH” Menu.
4. Once the timer expires the display will alternate between the water temperature and “
11.7 Programming the Time
To program the time, follow the steps below:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ TIME” Menu. The display will scroll
“ SET TIME.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to display the current time.
3. Press or to prepare the system for changes.
4. Press or to adjust and program the correct hour. Press
1
to save the change and move on to program the minutes.
5. The current minutes will blink as an indication that it is ready. Press
or to adjust and program the minutes. Press
1
to save the change and move on to program either AM or PM.
6. The current setting will blink as an indication that it is ready. Press
or to toggle between AM and PM. Once selected, press
1
to save the change. The system will return to the “ SET TIME” Menu.
36
J-300
11.8 Programming the Date
To program the date, follow the steps below:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ DATE” Menu. The display will scroll
“ SET DATE.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or and the current date will scroll. For example “ JAN 01
2016.”
3. Press or to display the year.
4. Press or to adjust and program the correct year. Press
1
to save the change and move on to program the month.
5. The current month will blink as an indication that it is ready. Press or to adjust and program the month. Press
1
to save the change and move on to program the day.
6. The current day will blink as an indication that it is ready. Press or
to scroll through the days. When the day is selected, press
1
to save the change. The system will return to the “ SET DATE” Menu.
11.9 Programming the Temperature Format
To program the temperature format, follow the steps below:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ TEMP” Menu. The display will scroll
“ TEMPERATURE FORMAT.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to switch between °F or °C. Once selected press
1 to save the change. The system will return to the “ TEMPERATURE
FORMAT” Menu.
11.10 Programming the Language
Your new spa comes with four language display options. To program the display language, follow the steps below:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
1. Press until you get to the “ LANG” Menu. The display will scroll
“ LANGUAGE MENU.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to display the current language.
3. Press or to scroll through the languages available. The choices are English, French, German and Spanish. Once a selection is made, press
1
to save the change. The system will return to the
“ LANGUAGE MENU.”
37
J-300
11.11 Programming the Lock Feature
You can prevent users from changing certain features of the spa. There are two lock modes to choice from:
Note: If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
• Access Lock will disable the ability to manually activate or adjust any feature of the spa. All scheduled operations will still be preformed.
• Settings Lock will disable the ability to change any of the user settings. You can still activate the jet pumps and lighting. All scheduled operations will still be preformed.
A. Activating a lock feature.
1. Press until you get to the “ LOCK” Menu. The display will scroll
“ LOCK MENU.” After the second scroll, if no action is taken, the system will revert back to the Main Menu.
2. Press or to switch from “ AL” (“ACCESS LOCK”) to “SL”
(“ SETTINGS LOCK”). Once a selection is made, press
1
to save the change. The system will return to the “ LOCK MENU.”
B. Deactivating a lock feature.
To deactivate a lock mode, press and hold for 10 seconds.
11.12 Resetting the Wi-Fi Connection (optional feature)
If there is a need to reset the Wi-Fi connection, follow the steps below:
Note:
• If no button is pressed within 5 seconds of each selection the screen will revert back to the Main Menu and the current settings will remain active.
• Any time the spa is connected to the Wi-Fi the Wi-Fi icon will be displayed.
1. Press until you get to the “ WIFI” Menu.
2. Press
1
to enter the reset menu. The display will read “ RSET” and scroll “ RESET WI-FI.”
3. Press
1
to reset the system.
38
J-300
12.0 Spa Maintenance
Proper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Jacuzzi dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this.
!
DANGER: RISK OF SEVERE INJURY OR DROWNING BY
ENTRAPMENT!
• Keep hair, loose articles of clothing or hanging jewelry away from suction fittings, rotating jets or other moving components to avoid entrapment that could lead to drowning or severe injury.
• Never use the spa unless all suction guards, filter, filter lid, or skimmer assembly are installed to prevent body and/or hair entrapment.
• Never operate or use the spa if the filter, filter lid, or skimmer assembly are broken or any part of the skimmer assembly is missing. Please contact your dealer or nearest service center for service.
• The suction fittings and suction covers in this spa are sized to match the specific water flow created by the pump(s). If it is necessary to replace the suction fittings, suction covers or pump(s), be sure that the flow rates are compatible and are in
compliance with the VGB Safety Act, page 2.
• Never replace a suction fitting or suction cover with one rated less than the flow rate marked on the original suction fitting.
Using improper suction fittings or suction covers can create a body or hair suction entrapment hazard that may lead to drowning or severe injury.
• Owners must alert all spa users to the potential risk of Hair,
Limb, Body, Evisceration (disembowelment), and Mechanical
12.1 Cleaning The Filters
Your Jacuzzi spa is equipped with a skimmer bag and two high performance pleated filter cartridges located under the filter cover. The circulation pump drawing water through the skimmer bag and filter cartridge filters fine debris. Large debris is filtered by jets pump 1 drawing water through the skimmer bag and second filter cartridge during an automated Secondary Filtration Cycle or when jets pump 1 is manually activated during spa use. Combined, both filters provide unsurpassed water quality by trapping surface oils and suspended particles. The filter cartridge should be cleaned once a month or as necessary, depending on use, for optimum performance.
39
J-300
An optional chemical feeder is available through your authorized Jacuzzi dealer that installs under the filter cap
(#2472-673). Always remove the chemical feeder cap and feeder (when used) during the filter cleaning process by turning the cap handle counterclockwise. Reinstall the cap and feeder back onto the filter cartridge after the filter cleaning process is complete. It is recommended that latex gloves be used to avoid touching the chemical feeder during the filter cleaning process.
Note: When used, the chemical feeder MUST remain on the circulation pump filter cartridge! This filter cartridge is the one with the grid across the wall fitting as shown (right).
TO DECREASE RISK OF DEATH, DROWNING OR ENTRAPMENT,
ALWAYS TURN POWER TO SPA OFF BEFORE CLEANING THE
FILTER CARTRIDGES!
Note: Refer to steps on following page for complete filter cleaning/replacement instructions.
A
DANGER:
TURN POWER TO SPA OFF! TO DECREASE
RISK OF DEATH, DROWNING, OR ENTRAPMENT, NEVER
OPERATE SPA WHEN FILTER IS NOT PROPERLY INSTALLED
OR IF SKIMMER ASSEMBLY IS DAMAGED OR ALTERED!
B C D
(Filter Cover Back View)
Lift upward on filter cover to remove it from the mating retaining clips. Then tilt forward to access filter cartridges.
Remove skimmer bag from clips, then clean out debris.
Rotate each filter cartridge handle counterclockwise to unthread from mating wall fitting.
40
E F G
Cartridge 1
J-300
Trapped
Air
Bubbles
Cartridge 2
Lift unthreaded filter cartridge from skimmer well.
If used, remove the chemical feeder as instructed prior to rinsing the filter cartridges.
Rinse debris from filter pleats on each cartridge using a garden hose and high pressure nozzle.
Start at the top and work downward towards handle. Repeat until all pleats are clean.
Submerge both filter cartridges in spa. Tilt threaded end upward to remove trapped air bubbles, then keep cartridges submerged to prevent air entrapment during installation (step
H).
H I J
(Filter Cover Back View)
Place each cartridge back into skimmer well, then rotated each cartridge handle clockwise to thread back into wall fitting. DO NOT
OVERTIGHTEN!
Install clean skimmer bag back onto the filter cover clips as shown.
Tilt filter cover back then gently press down to latch against retaining clips. Turn power to spa back on.
41
J-300
Periodically, the filter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning followed by soaking the filter overnight in a plastic container filled with a solution of water and specially formulated filter cleanser available from your authorized Jacuzzi dealer. The average life expectancy of each filter is approximately two years with proper care and water quality maintenance. Replacement cartridges may be purchased from your authorized Jacuzzi dealer.
12.2 Draining and Refilling
About every 3 months, you will want to replace the spa’s water. The frequency depends on a number of variables including the amount of use, attention paid to water quality maintenance, etc. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water even though the key water balance measurements are all within the proper parameters.
CAUTION! READ THIS BEFORE DRAINING: To prevent damage to the spa’s components, turn off power to the spa at the circuit breaker before draining it. Do not turn the power back on until your spa has been refilled.
CAUTION: There are certain precautions to keep in mind when draining your spa. If it is extremely cold, and the spa is outdoors, freezing could occur in the lines or the equipment, see “WINTERIZING” (page
45). On the other hand, if it is hot outdoors, do not leave the spa’s
surface exposed to direct sunlight.
To drain your spa, perform the following steps:
1. Turn off power to spa at breaker.
2. Locate the drain valve on the front/lower plastic pan. Hold the larger (rear) body to prevent it from turning, then loosen and remove the front cap to expose the underlying male hose threads.
3. Attach a garden hose to the exposed threads.
4. Gently rotate the larger (rear) valve body 1/3 turn counterclockwise to unlock the drain valve.
5. Pull the larger (rear) body outward to open drain.
6. After the spa drains, perform steps 2-5 in
1. Turn off power to spa.
2.
3.
4.
Unlock
Drain reverse order to close the drain prior to refilling the spa.
5.
Open Drain
After refilling, turn on power to the spa and follow
the steps listed under “Spa Fill Up Procedure” (page 20). Always fill
your spa through both filter wall fittings.
42
J-300
12.3 Pillow Care
Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. Always remove the pillows when adding chemical shock treatment to the spa water. The pillows can be returned to the spa when the sanitizer reading is stable as recommended on the inside cover of the manual.
To remove pillows:
1. Grasp pillow insert (A) with finger tips and gently pry outward from pillow base (B).
2. Grasp pillow base (B) with finger tips and gently pry outward from spa shell (C).
3. Assemble in reverse order after cleaning.
A
B
C
12.4 Cleaning The Spa Interior
To preserve the sheen of your spa’s surface, it is crucial that you avoid using abrasive cleaners or cleaners which have adverse chemical effect on the surface. If you are not certain as to the suitability of a particular cleanser, consult your authorized Jacuzzi dealer. Regardless of the cleanser used, use extreme care to assure that no soap residue is left on the surface. This could cause severe sudsing when the spa is refilled.
12.5 Cover Care and Maintenance
Certain hot tub covers distributed by Jacuzzi Hot Tubs have a vinyl or PROLAST™/PROLAST™ Extreme encasement. This vinyl or
PROLAST™/PROLAST™ Extreme encasement also referred to as the cover “skin” is attractive and durable. Regular monthly cleaning and conditioning (vinyl) is strongly recommended and may increase the longevity of your cover. Jacuzzi chemicals are for use in the U.S. only.
A. To Clean and Condition the Cover
1. Use a garden hose to loosen debris and dirt.
2. Using a large sponge or a soft bristle brush, use diluted or mild soap and scrub the vinyl top.
3. Rinse clean and do not allow soap to dry on cover. Do not use soap on the underside of the cover.
4. Please check with your Jacuzzi Dealer for recommended cover care and conditioning products. Condition using non-petroleum based conditioners to keep the vinyl supple and threads/stitching from drying out.
5. Do not use solvents, abrasive cleaners or strong detergents. Do not use products that contain silicone or alcohol.
B. Additional Care and Maintenance Instructions:
1. Debris can accumulate on the spa cover. Removal of snow or other debris will help to avoid breakage of the foam cores.
2. Be sure to lock the cover straps to secure the cover from unwanted or accidental entry.
3. Do not place heavy objects on the vinyl.
43
J-300
4. Do not walk, sit or stand on the cover.
5. Do not drag or use the flaps/skirt or the cover lock straps to remove the cover.
6. Use only recommended cover lift systems.
7. Use only chemicals and cleaners recommended by Jacuzzi.
8. Remember to keep spa covered when not in use. Maintaining proper water levels assures efficient operation and efficient electrical usage.
9. Do not expose your spa to the sun for extended periods of time as
UV rays can damage the interior surface.
10. Use caution when removing cover. Before removing cover, assure all locks have been released to avoid lock breakage and or cover strap damage.
12.6 Tool Free Access Door
The Tool Free Access door provides fast access to the equipment bay and components without the need of tools. To remove the door, follow the steps below.
Note: To avoid any injuries, more than one individual must perform these steps.
1. Locate the door’s retractable push button on the top of the front panel, Figure A.
2. Press the retractable push button to release the panel door from the spa frame, Figure B.
3. Slowly and gently tilt the panel forward to remove, Figure C. This will expose the equipment bay for easy access to the components. Place the panel in a safe location to prevent from damaging it.
4. To reinstall the panel just follow the steps above in reverse order.
Figure A
Figure B
Figure C
44
J-300
12.7 Maintaining The Synthetic Cabinet
Your new spa’s synthetic cabinet requires little or no maintenance of any kind. To clean, simply wipe cabinet with a clean towel and mild soap solution.
CAUTION: Never spray cabinet with a garden hose for any reason since this action may induce an electrical short in the spa’s electrical equipment.
12.8 Winterizing
Your Jacuzzi spa is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the electrical supply to the spa has not been interrupted. In extreme bitter cold weather, less than 32°F (0°C), program the primary
filtration cycle to run for 24 hours to prevent freezing (page 32).
If you do not intend to use your spa, or if there is a prolonged power outage during periods of severe freezing temperatures, it is important that all water be removed from the spa and equipment to protect against damage from freezing.
Expert winterization of your spa is highly recommended, contact
your authorized Jacuzzi dealer. In emergency situations, damage can be minimized by taking the following steps:
CAUTION: TURN OFF POWER TO HOT TUB!
1. Turn off power to the spa.
2. Follow the directions on page 42 for draining the spa.
3. Turn the massage/diverter selector(s) into the middle combo position
to allow the water in the plumbing lines to drain, page 30.
4. Turn the waterfall valve(s) to the open position to allow the water in
the plumbing lines to drain, page 30.
5. Open all the air controls and leave them open until you resume use of the spa, page 31.
6. As the water level drops below the seats, use whatever means necessary to get the water out of the recessed seating areas and into the footwell, such as a wet/dry vacuum.
7. When the water level ceases to drop, use whatever means available to remove any remaining water from the foot well, such as a wet/dry vacuum.
8. Remove the synthetic cabinet panel under the control panel and locate the drain plugs on the front of the pump(s), (Figure A, page
16). Remove plugs to allow water to drain out of pumps and
heater.
Note: Approximately one to two gallons will be released during this procedure. Use a wet/dry vacuum or other means to keep this from flooding the equipment compartment. Replace the drain plugs.
45
J-300
9. Loosen the hose clamp on the circulation pump intake behind the
control box (Figure A, page 16) and pull the hose off (twist hose
back and forth while pulling outward). Tip hose down and allow to drain, then reinstall hose and clamp.
10. Loosen hose clamp at bottom of CLEAR RAY® system and pull hose off of CLEAR RAY fitting (twist the hose back and forth while pulling downward). Tip hose down and allow to drain. Then reinstall hose and clamp. Remove the cover of the CLEAR RAY system to access the UV bulb and quartz tube. Remove and store the UV bulb in a safe location. Remove and dry off the quartz tube then reinstall it.
Depending on the length of time, consider replacing the UV bulb when you resume use of your hot tub.
11. Reinstall synthetic cabinet side panel and cover spa so that no casual moisture can enter into it.
Consult your authorized Jacuzzi dealer if you have any questions regarding winter use or winterizing.
12.9 Restarting Your Spa in Cold Weather
If you want to start up your spa after it has sat empty for a time in freezing temperatures, be aware that the water remaining in certain sections of the piping may still be frozen. This situation will block water flow preventing the spa from operating properly and possibly damaging the equipment. We recommend you consult your authorized Jacuzzi dealer for guidance before attempting to restart your spa under these conditions.
13.0 Water Quality Maintenance
To decrease the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water quality within specified limits. This will enhance your enjoyment and prolong the life of the hot tub’s equipment. Doing so requires regular attention because the water chemistry involved is a balance of several factors.
Procrastination in regard to water maintenance will result in poor and potentially unhealthful conditions for soaking and even damage to your hot tub investment. For specific guidance on maintaining water quality, consult your Authorized Jacuzzi dealer who can recommend appropriate chemical products for sanitizing and maintaining your hot tub.
!
WARNING: FAILURE TO MAINTAIN WATER QUALITY
WILL:
• Increase risk of contracting a waterborne illness (e.g. an infection bacteria or virus) and/or respiratory ailments.
• Damage the equipment, components and spa shell, which are not covered under the hot tub’s warranty.
46
J-300
CAUTION: Never store hot tub chemicals inside the hot tub’s equipment bay. The equipment bay may reach elevated temperatures, this is where high voltage electronic devices are located. This area is not intended for storage of any kind.
13.1 pH Control pH is a measure of relative acidity or alkalinity of water and is measured on a scale of 0 to 14. The midpoint of 7 is said to be neutral, above which is alkaline and below which is acidic. In spa water, it is very important to maintain a slightly alkaline condition of 7.4 to 7.6 pH. Problems become proportionately severe the further outside of this range the water gets.
A low pH will be corrosive to metals in the spa equipment. A high pH will cause minerals to deposit on the interior surface (scaling). In addition, the ability of the sanitation agents to keep the spa clean is severely affected as the pH moves beyond the ideal range. That is why almost all spa water test kits contain a measure for pH as well as the sanitizer.
13.2 Sanitizing
To destroy bacteria and organic compounds in the spa water, a sanitizer must be used regularly. Chlorine and bromine are the two most popular sanitizers used to date. The “Proclear Mineral Spa Clarifier” designed especially for your hot tub is a beneficial product for water maintenance.
Many other additives are available for your spa. Some are necessary to compensate for out-of-balance water; some aid in cosmetic water treatment and others simply alter the feel or smell of the water. Your authorized Jacuzzi dealer can advise you on the use of these additives.
When adding spa shock (chlorine or non-chlorine) or pH balancing chemicals activate the jets pump(s) and leave the spa cover open for a minimum of 20 minutes. By doing this you will allow excessive chemical vapors to exit the spa, protecting pillows and plastic knobs from chemical attack.
!
WARNING: RISK OF PERSONAL INJURY, DROWNING
OR ENTRAPMENT!
Never leave your hot tub unattended for any reason while the cover is open and accessible, especially to small children and animals!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemicals may damage components within your hot tub, burn or irritate your skin, create a rash and void the manufacturer warranty for your spa.
47
J-300
13.3 CLEARRAY® (Ultraviolet) Water Purification System
CLEAR RAY Water Purification System is exclusive DANGER!
TURN POWER
OFF! DO NOT
LOOK AT LIT BULB.
SEVERE EYE
DAMAGE OR BLINDNESS
CAN OCCUR!
technology utilizing natural ultraviolet technology to eliminate waterborne bacteria, viruses, and algae in portable spas. The ultraviolet light otherwise known as
UV-C or germicidal light inactivates the microorganisms
Power on
Lamp on disrupting the DNA so that it cannot reproduce and is considered lifeless. CLEAR RAY is plumbed in-line with your filtration system. After the water is drawn from the pump, filter, and heater it is then directed though the CLEAR RAY system. Water passes through an ultraviolet light energy that treats and disinfects the water. The water is then pumped back into the spa giving you crystal clear water instantly.
The system has a ballast that is the power supply for the purification system; it has two LED indicator lights. The “Power On” (red color) indicating incoming power flow and the “Lamp on” (green color) indicating the system is properly working. CLEAR RAY is standard for all models.
After a year the bulb must be replaced. If the UV timer has been programmed correctly a message will appear on the LCD display when the time allotted has expired. In order to clear the message a new UV
bulb needs to be installed and the timer must be reset (page 35).
!
WARNINGS:
• Do not operate the UV-C emitter when it is removed from the appliance enclosure.
• This appliance contains a UV-C emitter.
• Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin.
• Appliances that are obviously damaged must not be operated.
• Read the maintenance instructions before opening the appliance.
48
J-300
13.4 CLEARRAY® Bulb Replacement and Quartz Tube
Maintenance
Important: It is MANDATORY that the UV bulb is replaced and the quartz tube be cleaned every 12 months to maintain optimum performance.
10
11
1
2
3
9
5
7
8
6
4
#3 shown as reference only.
It is attached to the #10 metal plate.
12
Figure 1
!
DANGER:
TURN THE SPA BREAKER TO THE OFF
!
!
!
WARNING
:
DRAIN THE SPA IF YOU ARE REPLACING OR
CLEANING THE QUARTZ TUBE!
WARNING: ALLOW BULB TO COOL DOWN PRIOR TO
REMOVING FROM QUARTZ TUBE.
DANGER:
NEVER LOOK AT THE LIT BULB. THIS CAN
CAUSE SEVERE EYE DAMAGE OR BLINDNESS.
UV BULB REPLACEMENT AND QUARTZ TUBE MAINTENANCE:
Note: Location of CLEARRAY System and connection may vary by model.
1. Turn the breaker to the spa OFF. DRAIN YOUR SPA.
Note: If you are only replacing the UV bulb then the spa does not have to be drained. You will need to drain it if you are replacing or cleaning the quartz tube.
2. Once the UV bulb has cooled off remove the
CLEAR RAY System enclosure cover (2) by removing the four screws (1). This will expose the UV bulb and connections, Figure 2.
Figure 2
!
DANGER:
NEVER REMOVE COVER WITHOUT FIRST
TURNING OFF AT POWER SOURCE AND DRAINING THE
SPA.
49
J-300
Figure 3 Figure 4 Figure 5 Figure 6
9
7
Power Lamp
On
4 6
3. Disconnect UV bulb socket (6) from the power cord socket (4),
Figure 3.
4. Slowly remove the UV bulb (7) out of the quartz tube, Figure 4.
5. Remove the quartz seal compression nut (9) by turning it
counterclockwise, Figure 5. Use a pair of channel-lock pliers if needed, Figure 6.
6. Now you are ready to clean or replace the quartz tube (8). For cleaning the quartz tube, follow steps 7 and 8 then proceed from step 9.
For replacing quartz tube, skip steps 7 and 8 and proceed from step 9.
7. Cleaning quartz tube: Clean the quartz tube by wiping, until clear, using a paper towel or a dry cotton cloth. If needed, a household tub and shower lime removal product can be used.
!
WARNING: Do not use abrasive cleaners as they can scratch the quartz tube surface.
8. Rinse the quartz tube with clean water to completely remove any cleaning products that were used in step 7.
9. Replacing quartz tube: Remove the black o-ring from the quartz tube and place it on the new tube. Place the new quartz tube (8) into the water chamber (12) with the domed end first making sure it is inserted and seated inside the quartz end holder (11).
10. Reinstall and hand tighten the quartz seal compression nut (9) by turning it clockwise.
11. Refill your spa.
12. System Test 1: Assure there is no water dripping from the seal compression nut (9). If water is visible, STOP and tighten the compression nut (9) using a pair of channel lock pliers to a maximum of 1/4 turn. If that does not fix the leak, then repeat quartz tube maintenance process from step 1 through step 11. Make sure there is no water leaking before proceeding to step 13.
13. System Test 2: Reconnect the CLEARRAY unit to the controller.
Turn breaker back ON. Turn on the pump to circulate the water through the CLEAR RAY System. Wait for 5 minutes and assure no water is dripping. If water is visible, STOP, fix the leak by repeating quartz tube maintenance process from step 1 through step 12. Make sure there is no water visible. Turn the pump and breaker OFF
BEFORE proceeding to step 14.
14. Reconnect the UV bulb socket (6) to the power cord socket (4) make sure you use the latex glove provided when handling the UV bulb.
50
!
J-300
WARNING: DO NOT TOUCH THE NEW UV BULB WITH
YOUR BARE HAND. Oil on your skin will cause hot spot on the UV bulb and shorten the life of your UV bulb. Use the provided latex glove to handle the UV bulb.
15. Slide the new UV bulb (7) back inside the quartz tube.
16. Reinstall the black bulb boot (5) back over the quartz seal compression nut (9).
17. Reinstall the enclosure cover (2) and secure with the screws.
18. Properly dispose of the old UV bulb.
!
WARNING: This CLEAR RAY System includes a UV bulb, which contains mercury. Dispose of the bulb in accordance with disposal laws. See www.lamprecycle.org.
19. Once power is activated you can check the ballast,
Figure 7, to see if the CLEAR RAY System is
DANGER!
TURN POWER
OFF! DO NOT
LOOK AT LIT BULB.
SEVERE EYE
DAMAGE OR BLINDNESS
CAN OCCUR!
functioning. The power on (red) light indicates that the
CLEAR RAY System is being provided power and should always be on. The lamp on (green) light indicates that UV bulb is activated.
Figure 7
14.0 Error Conditions/Error Messages
Your spa has a self-diagnostic control system. The system will automatically display the following if a problem is detected. Always insist on genuine Jacuzzi replacement parts.
14.1 Summer Logic
When the actual spa water temperature reaches 2°F (1°C) above the set temperature, the spa goes into “summer logic.” The circulation pump will turn off automatically, if running, to avoid adding additional heat to the water, eventually creating an overheat condition. This setting is not user-programmable.
Note: Summer logic does not take effect until the spa water temperature reaches 95°F (35°C). This condition is more likely in excessively hot weather. Remember, the spa’s ability to cool is directly affected by the ambient temperature. An excessively hot ambient temperature may prevent the spa from cooling down because it’s fully insulated construction is designed to retain heat and minimize operating costs.
14.2 Panel Displays COOL
Cool Condition - Temperature has dropped 20°F (11°C) below the current set temperature. The circulation pump and the heater have been activated to bring the temperature within 15°F
(8°C) of the set temperature. No corrective action is required!
Note: This condition is common during first time fill ups or during refills since tap water is often very cold.
51
J-300
14.3 Panel Displays ICE
Freeze Protection - A potential freeze condition has been detected. No action is required. Water temperature is below
55°F (12.78°C). Jets Pump 1, Jets Pump 2 and the circulation pump will activate for 10 minutes, then turn off. Then the circulation pump and the heater will activate for 10 minutes. The two cycles shall repeat until the
water temperature reaches 65°F (18.33°C). See “Winterizing” (page 45).
14.4 Panel Displays SN--1
Open sensor (heater is disabled) or shorted sensor (spa is deactivated). The high-limit temperature sensor is not functioning. Contact your authorized Jacuzzi dealer or qualified service technician. The display will alternate between “SN--1”, scrolling message “HI-LIMIT SENSOR ERROR” and the current water temperature.
14.5 Panel Displays SN--2
Open or shorted sensor (heater disabled). The temperature sensor is not functioning. Contact your authorized Jacuzzi dealer or qualified service technician. The display will alternate between
“SN--2” and the current water temperature. The display will alternate between “SN--2”, scrolling message “WATER SENSOR ERROR” and the current water temperature.
14.6 Panel Displays Change CLEARRAY Bulb
The CLEAR RAY bulb timer has expired. UV bulb needs to be replaced.
The display will alternate between the current temperature reading and the scrolling message “CHANGE CLEARRAY BULB” as long as the error exists. The countdown timer for the UV bulb needs to be reset (page
35). A new UV bulb can be purchased from a local Jacuzzi dealer.
14.7 Panel Displays Change Filter
The filter change timer has expired. The spa filters need to be cleaned or replaced. The display will alternate between the current temperature reading and the scrolling message “CHANGE FILTER” as long as the error exists. The countdown timer for the Change Filter feature needs to
be reset (page 35). New filters can be purchased from a local Jacuzzi
dealer.
14.8 Panel Displays Change Water
The water refresh timer has expired. The spa needs to be drained and refilled. The display will alternate between the current temperature reading and the scrolling message “CHANGE WATER” as long as the error exists. The countdown timer for the Change Filter feature needs to
be reset (page 36). New filters can be purchased from a local Jacuzzi
dealer.
52
J-300
14.9 Panel Displays FL--1
An “FL--1” display means the flow switch is malfunctioning open, the filter cartridge is excessively dirty or an “air lock” condition has occurred at the circulation pump intake. The spa heater will deactivate and jets pump #1 may also deactivate. Contact your authorized Jacuzzi dealer or qualified service technician. The display will alternate between “FL--1,” scrolling message “FLOW ERROR OPEN” and the current water temperature.
14.10 Panel Displays FL--2
An “FL--2” display means the flow switch is malfunctioning closed. The spa heater will deactivate and jets pump #1 may also deactivate. Contact your authorized Jacuzzi dealer or qualified service technician. The display will alternate between “FL--2,” scrolling message “FLOW ERROR CLOSED” and the current water temperature.
14.11 Panel Displays OH
!
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
Water temperature is above acceptable limits. DO NOT
ENTER SPA! Water temperature has reached 112°F (44°C).
The circulation pump has activated to circulate water through heater. Contact your authorized Jacuzzi dealer or qualified service technician. The display will alternate between “*OH*” and the current water temperature.
Note: As a safety measure, the red lights of the spa will flash on and off as an indication that the spa is an overheat condition.
To correct condition:
• Remove the spa’s cover and allow your spa to cool down.
• Program the heater settings for Economy Mode (page 34). Raise
water temperature setting to cancel Summer Logic condition (page
• If the condition persists, contact your authorized Jacuzzi dealer.
14.12 Panel Displays (-- -- -- --)
!
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
Water temperature is above acceptable limits. DO NOT
ENTER SPA! The safety “Watchdog” software has been triggered and the spa is deactivated. A problem has been detected which could cause damage to the spa or its components. The display will alternate between “-- -- -- --” and the scrolling message
“WATCHDOG CALL FOR SERVICE” as long as the error exists.
Contact your authorized Jacuzzi dealer or qualified service technician.
Note: As a safety measure, the red lights of the spa will flash on and off as an indication that the spa is in watchdog condition.
53
J-300
15.0 Troubleshooting Procedures
In the event your Jacuzzi spa is not working the way it should, please first review all the installation and operating instructions in this manual and check for messages on the panel display. If you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions below. Always insist on genuine Jacuzzi replacement parts.
Note: If any of the supply cords to accessories are damaged, they must be replaced by authorized service personnel. Contact your authorized
Jacuzzi dealer or qualified service technician.
15.1 FL--1 and FL--2
To try an correct an FL--1 and FL--2 condition perform the following:
1. Turn power off!
2. Verify water level is above all jets but below lowest pillow. Add water if necessary.
3. Check for clogged or dirty filter cartridge (Sec. 12.1, page 39).
4. Purge “air lock” from circulation pump intake by removing filter cartridge. Hold your garden hose over the filter cartridge wall fitting while using a rag as a seal around hose end. Ask a helper to turn on water for 30 seconds, then turn off. Reinstall filter cartridge and
check spa (Sec. 12.1, page 39).
5. If the circulation pump is not running, turn power off at the main breaker, then turn power back on.
6. If problem persists, contact your authorized Jacuzzi dealer.
15.2 None of the Components Operate (e.g. Pump, Light)
Check the following:
1. Is there power to the spa?
2. Is the household circuit breaker tripped?
3. Contact your authorized Jacuzzi dealer or qualified service technician.
15.3 Pump Does Not Operate
Press the JETS 1 button. If no water movement is detected, make sure power is going to the spa and check the water level. If this does not solve the problem, contact your authorized Jacuzzi dealer or qualified service technician. The main jets pump 1 operates but no water flows to jets.
Check the following:
1. Jets may all be closed. Verify all jets are in the open “on” position
2. Pump may not be properly primed. This can happen after the spa is drained and refilled. Press the JETS 1 button on the control panel several times, never leaving the motor running for more than 5 to 10 seconds at a time. Turn power off and let the air out of spa plumbing
system by removing the filter cartridge (Sec. 12.1, page 39). Make
certain you reinstall the filter cartridge before turning on spa power and restarting the jets pump 1.
54
J-300
15.4 Poor Jet Action
• Make sure all jets are in the full open “on” position (page 30).
• Press the JETS 1 button to make certain pump #1 is on.
• Verify all air controls are in the “on” position by pressing down on their Jacuzzi Logo (page 31).
• Check for dirty filter. Clean, if necessary (Section 12.1, page 39).
15.5 Water is Too Hot
Reduce thermostat setting.
15.6 No Heat
1. Check thermostat setting.
2. Keep the spa cover in place while heating.
3. Check the settings to see if your spa is in economy mode (page 34).
Should checking the above steps fail to correct the problem, please call your Jacuzzi Hot Tub dealer so that they may arrange service. We build the best spas in the industry. Nonetheless, we are always striving to improve the quality and features of our products.
Your input as a Jacuzzi spa owner is a cherished part of this process. If you have any comments or suggestions, or if you wish to be informed on any new products for your spa, please write to us.
CONGRATULATIONS on your good taste and welcome to the happiest and most relaxed family in the world!
55
J-300
16.0 Circuit Board Diagrams
16.1 North American J-335, J-345, J-355, J-365, J-375 and J-385
Dedicated Power Models (60 Hz)
This wiring diagram is used for all North American, 240V (60 Hz) dedicated power models.
CLEAR RAY
STEREO POWER
SUPPLY (OPTIONAL)
CONTROL
PANEL
WI-FI
(OPTIONAL)
FLOW
SENSOR
WATER
SENSOR
LIGHTING
EXPANSION
1 2 3 4 5 6 7 8 9 10
S1
J18
ON
J17
J50
J59
J56 J57
J51
J14
1 2 3 4 5 6 7 8 9 10
S1
J9
ZONE 2
J24
See Section 17.0
for Dip Switch
Settings
ZONE 1
PUMP 2
F4
J29 J34
J27
J33
J41
J36
J47
J46
J38
J53
5A
5AT~250V
240VAC, 26A/37A/48A
3-WIRE CONNECTION
60HZ 1-PHASE SERVICE
THERMAL
CUTOFF
CIRC PUMP
PUMP 1
5.5KW HEATER
RISK OF SHOCK OR ELECTROCUTION!
Turn power off before servicing. This task should only be performed by a quali
56
J-300
16.2 North American J-315 and J-325 Convertible Power Models
(For a 3-wire 120V 60 Hz connection)
This wiring diagram is used for all North American
120V 60 Hz convertible power models.
Note: Refer to Section 16.3 for a 4-wire 240V connection.
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
1 2 3 4 5 6 7 8 9 10
Turn power off before servicing. This task should only be performed by a qualified technician.
CLEAR
STEREO POWER
SUPPLY (OPTIONAL)
RAY CONTROL
PANEL
WI-FI
(OPTIONAL)
FLOW
SENSOR
WATER
SENSOR
S1
J17 J18
ON
J59
J56 J57
J51
J14
1 2 3 4 5 6 7 8 9 10
S1
J9
ZONE 2 STEP LIGHT
(OPTIONAL)
J24
See Section 17.0
for Dip Switch
Settings
ZONE 1
LIGHTING
EXPANSION
F4
J41
J33 J36
J47
J46
J38
J53
J29 J34
J27
G-GRN
CIRC PUMP
PUMP 1
120 VAC, 12A
3-WIRE CONNECTION
60HZ 1-PHASE SERVICE
240 VAC, 24A/32A
4-WIRE CONNECTION
60HZ 1-PHASE SERVICE
5A
5AT~250V
1.0KW
G-GRN
57
J-300
16.3 North American J-315 and J-325 Convertible Power Models
(For a 4-wire 240V 60 Hz connection)
This wiring diagram is used for all North American 240V 60 Hz convertible power models. Dedicated 240V models must be permanently connected (hard-wired) to the power supply.
Note: 240 VAC 4-wire connection enhances heater output from 1kW to
4kW.
120V 120V
240V
J22
F3
WHT
Location J22 remove one logic jumper and place the other across the
240V pins, as shown
G-GRN
BLK
J22
4A
J49
F2
See Section 17.0
for Dip Switch
Settings
A/V
30A (PMP 2)
F6
UV
FROM
J37
J51
J59
J33
J22
TO
J38
J46
J53
J47
1 jumper
A
TB1
30A (PMP 1)
P1 2SPD
J44
J35
J37
OZONE
J72 CIRC PUMP
L-BLK
J73
N-WHT
D
C
B
G-GRN
4.0KW
WHT
BLK
RED
G-GRN
D
240 VAC, 20A/31A
C
B
A
TB1
G-GRN
WHT
BLK
RED
G-GRN
PUMP 1
TB1 terminal
White wire must be connected to location D and
CIRC PUMP a second hot wire connected
( RED), as shown
Jumper wires
The sequence of the jumper wires must be changed, as shown
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
Turn power off before servicing. This task should only be performed by a qualified technician.
58
J-300
16.4 Export J-335, J-345, J-355, J-365, J-375 and J-385 Models
(50 Hz)
This wiring diagram is used for all Export 230 VAC 50 Hz spa models.
1 2 3 4 5 6 7 8 9 10
CLEAR
STEREO POWER
SUPPLY (OPTIONAL)
RAY
CONTROL
PANEL
WI-FI
(OPTIONAL)
FLOW
SENSOR
LIGHTING
EXPANSION
WATER
SENSOR
S1
ON J17 J18
J50
J59
J56 J57
J51
J14
ZONE 2
1 2 3 4 5 6 7 8 9 10
S1
J9
ZONE 1
See Section 17.0
for Dip Switch
Settings
PUMP 2
F4
J41
J33 J36
J47
J46
J38
J53
J29 J34
J27
5A
5AT~250V
THERMAL
CUTOFF
CIRC PUMP
PUMP 1
230VAC, 50HZ
SINGLE SERVICE 29A
DUAL SERVICE 12A/17A
THREE SERVICE 12A/10A/7A
2.7KW HEATER
RISK OF SHOCK OR ELECTROCUTION!
Turn power off before servicing. This task should only be performed by a quali
59
J-300
16.5 Export J-315 and J-325 Models (50 Hz)
This wiring diagram is used for all Export 230 VAC 50 Hz spa models.
CLEAR RAY
STEREO POWER
SUPPLY (OPTIONAL)
CONTROL
PANEL
WI-FI
(OPTIONAL)
FLOW
SENSOR
LIGHTING
EXPANSION
1 2 3 4 5 6 7 8 9 10
S1
WATER
SENSOR
ON
J17 J18
J59
J56 J57
J51
J14
1 2 3 4 5 6 7 8 9 10
S1
J9
ZONE 2 STEP LIGHT
(OPTIONAL)
J24
ZONE 1
See Section 17.0
for Dip Switch
Settings
F4
J41
J33 J36
J47
J46
J38
J53
J29 J34
J27
5A
5AT~250V
CIRC PUMP
PUMP 1
230VAC, 50HZ
SINGLE SERVICE 22A
DUAL SERVICE 10A/12A
2.7KW
G-GRN
RISK OF SHOCK OR ELECTROCUTION!
Turn power off before servicing. This task should only be performed by a quali
60
J-300
17.0 Dip Switch Settings and Wiring
17.1 Switch settings for Domestic 60Hz Models
The dip switches are at the S1 location on the board.
OFF
40A
240V DOMESTIC
DIP SWITCH SETTINGS
S1 LOCATION
ON
50A
(factory default)
OFF ON OFF
60A
ON
7
8
5
6
3
4
1
2
9
10
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
7
8
5
6
3
4
1
2
9
10
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
7
8
5
6
3
4
1
2
9
10
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
BREAKER
1 2 3 4
DIP SWITCH NUMBER
5 6 7 8 9 10
40A OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
50A*
60A
OFF OFF ON
*50A is the factory default setting
OFF OFF OFF OFF OFF OFF OFF
OFF OFF OFF ON OFF OFF OFF OFF OFF OFF
120V/240V CONVERTIBLE
DOMESTIC DIP SWITCH SETTINGS
S1 LOCATION
15A
(factory default) 30A 40A
OFF ON OFF ON OFF ON
6
7
4
5
1
2
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
4
5
1
2
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
5
1
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
BREAKER
1 2 3 4
DIP SWITCH NUMBER
5 6 7 8 9 10
15A* OFF ON OFF OFF ON OFF OFF OFF OFF OFF
30A
40A
OFF ON
OFF ON
ON ON OFF OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF OFF OFF OFF
*15A is the factory default setting (GFCI Cord)
61
J-300
17.2 Switch settings for Export 50Hz Models
EXPORT DIP SWITCH SETTINGS
S1 LOCATION
1x16A
OFF ON
7
8
5
6
3
4
1
2
9
10
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1x20A
7
8
5
6
3
4
1
2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
2x16A
ON
7
8
5
6
3
4
1
2
9
10
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EXPORT DIP SWITCH SETTINGS
S1 LOCATION
OFF
1x32A
6
7
4
5
1
2
ON
9
10
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
1x40A or
1x16A/1x32A
OFF ON
ON
OFF
7
8
5
6
3
4
1
2
9
10
OFF
ON
OFF
OFF
OFF
OFF
OFF
1x16A/1x20A
OFF
7
8
5
6
3
4
1
2
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3x16A
7
8
5
6
3
4
1
2
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
BREAKER
1 2 3 4
DIP SWITCH NUMBER
5 6 7 8 9 10
1x16A ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
1x20A
2x16A
1x32A
1x40A or
1x16A/1x32A
ON OFF OFF ON
ON OFF ON
ON OFF ON
OFF OFF OFF OFF OFF OFF OFF
ON
ON OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF OFF
ON OFF OFF OFF ON OFF OFF OFF OFF OFF
1x16A/1x20A ON OFF ON OFF ON OFF OFF OFF OFF OFF
3x16A ON OFF OFF ON OFF OFF OFF OFF OFF OFF
62
J-300
Single Service (default setting)
1x16A (J315/J325 Only) This setting will turn the heater off any time the jets pump is activated.
1x20A
1x32A
This setting will turn the heater off any time either one of the pumps are activated on two pump models.
This setting is for all two pump model spas. Both pumps and the heater will be allowed to operate at the same time.
Dual Service
2x16A (J315/J325 Only) Both the jets pump and the heater will be allowed to operate at the same time.
1x16A/1x20A This setting is for all two pump model spas. Both pumps and the heater will be allowed to operate at the same time.
Three Phase Service
3x16A This setting is for all two pump model spas. Both pumps and the heater will be allowed to operate at the same time.
63
J-300
17.3 Single Service 50Hz Connection
Wiring for export models with a single service breaker. The jumper wiring is shown below.
The included extra White wire (1*) must be installed.
ALL MODELS
Single Service Jumper Wiring
Wire
1*
From
J33
To
J47
2
3
4
J59
J37
J46
J41
J36
J51
*Extra connection must be made
BREAKER TERMINAL
CONNECTIONS
L1 = All components
4
A/V
30A (PMP 2)
F6
UV
J49
1*
2
30A (PMP 1)
P1 2SPD
3
J37
J44
J35
D
C
B
A
L1 BRN
N1 BLU
G-GRN
17.4 Dual Service 50Hz Connection
Wiring for export models with dual service breakers. The jumper wiring is shown below.
ALL MODELS
Dual Service Jumper Wiring
Wire From
1 J33
To
J51
2
3
J59
J37
J38
J53
BREAKER TERMINAL
CONNECTIONS
L1 = Heater & Transformer
L2 = All other components
2
1
A/V
30A (PMP 2)
F6
UV
J49
30A (PMP 1)
P1 2SPD
J44
J35
3 J37
D
C
B
A
N2 BLU
L1 BRN
N1 BLU
L2 BRN
GRN
64
J-300
17.5 Three Service 50Hz Connection
Wiring for export models with a three service breaker. The jumper wiring is shown below.
ALL MODELS
Three Service Jumper Wiring
(except the J315 and J325)
Wire
1
From
J38
To
J51
2
3
J59
J37
J41
J36
1
A/V
30A (PMP 2)
F6
UV
2
J49
D
C
B
A
L3 BRN
L1 BRN
N1 BLU
L2 BRN
GRN
30A (PMP 1)
P1 2SPD
3 J37
J44
J35
BREAKER TERMINAL
CONNECTIONS
L1 = Heater & Transformer
L2 = Pump 1 and other components
L3 = Pump 2
65
J-300
18.0 Optional BLUEWAVE® Spa Stereo System
To start enjoying your new stereo receiver, please read the following operation instructions in their entirety.
3.5 mm cable
30-pin
Connector
2
6 7
1
AUX
USB
3 4
5
USB connector
1. Media Locker Handle
Slide the handle to lock and unlock the protective door.
2. Power Button
Press power button once to turn “ON” stereo system. Press a second time to place the stereo in “Standby” mode and the red light will remain illuminated.
3. Auxiliary Input Jack Connector
Allows you to connect an auxiliary device by using a 3.5 mm cable.
4. Universal Serial Bus (USB) Device Connector
Allows you to connect your device via a USB port and a USB cable compatible with your device.
5. Auxiliary Device Holding Base
The removable base securely holds the Auxiliary device, such as an iPod®/MP3/iPhone®, in place. It can be removed for larger devices.
6. 3.5 mm Cable (purchased separately)
Use this cable to connect your Auxiliary or MP3 device to the stereo via the “AUX” connection.
7. Apple 30-pin to USB Cable (purchased separately)
Use this cable to connect your compatible iPod, iPhone or MP3 device to the stereo via the “USB” connection.
66
J-300
WARNING: RISK OF ELECTRICAL SHOCK HAZARD
EXISTS AND EQUIPMENT DAMAGE! Never install or remove electrical devices (e.g. Apple device/MP3/USB/AUX/
Bluetooth) while hands are wet or while sitting partially or fully immersed in the spa!
CAUTION: Never leave electrical devices in the Media Locker when spa is not is use to prevent damage from outdoor elements! Never spray Media Locker with a pressurized water hose for any reason! Damage to the device or spa stereo system caused by water intrusion is not covered under the manufacturer's warranty! Damage to Media Locker port or electrical devices due to excessive force or improper alignment during installation or removal from Media Locker is not covered under warranty.
18.1 Pairing the Remote and Stereo
In order for the remote to operate the stereo, you need to pair them using the following method:
1. Make sure the stereo unit is in "Standby" mode.
LED power light will be red, Figure A.
2. Press any button on the remote to turn it ON.
The remote LCD display will read “No Link.”
3. Press and hold the “Mode” button on the remote (Figure B).
At the same time, press and hold the power button on the stereo for 2 seconds (Figure A).
4. The remote LCD display will read “Welcome,” “Load” and
“Radio” if the pairing sequence was successful.
AUDIO
Figure A
MODE
1
DIR -
2 3
REPEAT DIR + RANDOM
Figure B
18.2 Audio Settings
The Audio button, Figure C, provides access to many of the stereo’s settings. By continually pressing the Audio button you can scroll and adjust the following functions: BAS-TRE-BAL-FAD-
DSP-AREA-LOUD-DX-STEREO (respectively).
Note: You can adjust the settings by pressing the Audio button, making your adjustments and pressing the Audio button to go the next feature. If you exit the setting menus continually press the Audio button until you reach the setting you would like to adjust.
AUDIO MODE
1
DIR -
2 3
REPEAT DIR + RANDOM
Figure C
1. Bass Setting: Press the Audio button once to access the bass setting. The LCD display will change to “BAS 0,”
Figure D. Press the Up button to adjust the setting to a maximum of +5. Press the Down button to adjust the setting
Figure D down to -5.
Note: The default setting is “0.” This feature is disabled when a “Digital
Sound Processor” (DSP) setting is active such as “Rock,” “Classic,” or
“Pop.”
67
J-300
2. Treble Setting: Press the Audio button 2 times to access the treble setting. The LCD display will change to “TRE 0,”
Figure E. Press the Up button to adjust the setting to a maximum of +5. Press the Down button to adjust the setting
Figure E down to -5.
Note: The default setting is “0.” This feature is disabled when a “Digital
Sound Processor” (DSP) setting is active such as “Rock,” “Classic,” or
“Pop.”
3. Balance Setting: Press the Audio button 3 times to access the balance setting. The LCD display will change to “BAL L=R,” Figure F. Press the Up button to adjust the setting to a maximum of 10R (only the right side speakers will have volume). Press the Down button to adjust the setting down to 10L (only the left side speakers will have volume).
Figure F
4. Fade Setting: Press the Audio button 4 times to access the fade setting. The LCD display will change to “FAD
F=R,” Figure G. Press the Up button to adjust the setting to a maximum of 10F (only the front speakers will have volume).
Figure G
Press the Down button to adjust the setting down to 10R
(only the rear speakers will have volume).
5. Digital Sound Processor (DSP) Setting: Press the Audio button 5 times to access the DSP setting. The LCD display will change to “DSP OFF,” Figure H. Press the Up button to select one of the preset settings such as Rock,
Classic or Pop. If a preset setting is select a small icon will appear on the LCD display, Figure I.
Figure H
ROCK
Figure I
6. Area Setting: Press the Audio button 6 times to access the Area setting. The LCD display will change to “AREA
USA,” Figure J. Press the Up button to select either USA or
EUR setting.
7. Loud Setting: Press the Audio button 7 times to access the Loud setting. The LCD display will change to “LOUD
OFF,” Figure K. Press the Up button to select either OFF or
ON.
Figure J
Figure K
8. Distant Setting: Press the Audio button 8 times to access the Distant setting. The LCD display will change to “DX,”
Figure L. Press the Up button to select either Distant (DX) or Local for station frequency. The “LOCAL” setting allows for better FM reception when a local station is too strong. Leave the setting to “DX” if this condition does not exist.
Figure L
9. Stereo Setting: Press the Audio button 9 times to access the Stereo setting. The LCD display will change to
“STEREO,” Figure M. Press the Up button to select either
Stereo or Mono.
68
Figure M
J-300
18.3 Wireless Remote Control Functions
A wireless radio frequency (RF) remote control is supplied on all spas with the optional audio system. This remote provides control of the radio and over some media device functions.
AUDIO MODE
A.
External Media Device Playback
The supplied remote control provides no control over external
1
DIR -
2 3
REPEAT
Auxiliary player operation except for volume control and source selection. The Auxiliary player performs all external Auxiliary playback operations.
DIR +
Button
AUDIO
MODE
RANDOM
Operation
Power Button: Press once to turn remote “ON” (remote LCD display will read “No Link”; Press a second time to turn stereo “ON” (remote
LCD display will read “Welcome”); Press a third time to place the stereo in “Standby” mode.
Audio Button: Allows access to most of the stereo sound functions.
Press continuously to scroll through the following settings (if applicable): Bas-Tre-Bal-Fad-DSP-Area-Loud-DX-Stereo.
Mode Button: Press continuously to switch between “RADIO,”
“USB” and “AUX IN” modes. “BT AUDIO” appears when a Bluetooth device is paired with the stereo.
Volume Up Button: Used to increase volume between 0 to 30.
Volume Down Button: Used to decrease volume between 30 to 0.
Button Device Mode (USB)
Play/Pause Button: Press to pause track, press again to resume playing
Track Down Button: Press to rewind tracks.
Track Up Button: Press to move forward tracks.
1
DIR -
2
REPEAT
3
DIR +
Press the button to change music folders.
Apple Device: Press once to repeat song. Press again to repeat entire album. Press again to turn off.
USB Mode: Press once to turn on. Press again to turn off.
Press the buttons to change music folders.
RANDOM
Press to play songs in a random order.
Radio Mode
Mute Button: Press to mute sound, press again to reactivate sound
Seek Down Button: Seeks down for stations.
Seek Forward Button: Seeks forward for stations.
Preset 1: Press to access a preset station.
Preset 2: Press to access a preset station.
Preset 3: Press to access a preset station.
Not used
69
J-300
18.4 Electronic Device Connections and Functions
IMPORTANT:
• If stereo unit is “ON” (blue light is illuminated on the stereo power button) then press the power button on the remote once.
• If stereo unit is in “Standby” (red light is illuminated on the stereo power button) then press the power button on the remote once to activate the remote (remote LCD display will read “NO LINK”).
Press the button again to activate the stereo unit (remote LCD display will read “WELCOME”).
A. Operating the Radio:
1. Turn power “ON” to the stereo unit. Press the power button on the remote.
2. The LCD screen on the remote will display the following:
Figure A
“Welcome,” “Load,” “Radio” and the station number, Figure A.
3. You can use the seek button to search for frequencies.
4. You can save up to 3 stations as presets. Follow the steps below to set a station: a. Find a station you want to save.
b. Press and hold one of the three preset buttons. The station preset number (1, 2 or 3) on the display will quickly flash to confirm the setting. To set the additional two stations, conduct this step again.
B. Connecting Your Apple Device and MP3 Player Using the USB:
1. Locate the USB port in the stereo locker (Figure B).
2. Use a 30-pin cable for compatible devices (Figure C) or a cable provided with your device.
3. Connect the USB end of the cable into the USB connection on stereo.
4. Connect the 30-pin end of the cable to the Apple device/MP3 Player
(purchased separately), Figure D.
5. After connecting the cable to both devices, set the player into the rubber holding base, Figure E.
Note: This also charges most compatible Apple devices when connected.
AUX USB AUX USB
ACCESSORY CONNECTED
70
Figure B
Figure C
(purchased separately)
Figure D
(device purchased separately)
Figure E
J-300
CAUTION: RISK OF ELECTRICAL SHOCK OR EQUIPMENT
DAMAGE!
Never install, remove or operate any electrical device (e.g.
Apple device/MP3/USB/AUX/Bluetooth) while hands are wet or while sitting partially or fully immersed in the spa!
Note: The DRM (Digital Rights Management) Files cannot be played on this deck. Personal files (MP3, WMA, iTunes or
AAC) can be played as long as they are not DRM encrypted.
C. Operating USB/MP3/Apple device
1. Turn power “ON” to the stereo unit. Turn power “ON” to the remote.
2. The LCD screen on the remote will display the following: “Welcome,”
“USB,” “Load,” “Apple” (final display will vary depending on the device connected). All functions are performed through the remote.
3. While the music is playing the remote screen will display and continually scroll through the following: Artist, Album, Song and Track information.
4. For operational functions refer to the “External Media Device
Playback” section.
D. Operating the USB drive:
1. Plug in your USB device into the “USB” connection on the stereo,
Figure A.
2. Turn power “ON” to the stereo unit and the stereo remote.
3. The LCD screen on the remote will display the following: “Welcome,”
“USB,” “Load,” “TOL XX” (final display will vary depending on the whether the USB holds folders or files). All functions are performed through the remote.
4. While the music is playing the remote screen will display and continually scroll through the following: Title, Song, Artist, Album, Dir,
Music and Track information.
5. For operational functions refer to the “External Media Device
Playback” section.
E. Connecting Your Auxiliary Player Using the 3.5 mm Cable:
1. Plug one end of the cable to “Aux” connection on the stereo, Figure F.
2. Plug the other end of the cable into the phone jack
AUX USB connection on the Apple device/MP3 Player.
3. Press the Mode button on the remote to “AUX IN.”
4. All playback operations are conducted via the
Auxiliary Player. The stereo remote functions do not work on the external Auxiliary Player (except volume control).
Figure F
71
J-300
F. Connecting Your Bluetooth Device:
1. Turn power “ON” to the stereo unit.
2. From your Bluetooth device, make sure the Bluetooth setting is “ON.”
3. Follow the pairing instructions for your Bluetooth device and connect to the “BLUEWAVE” device that appears on your screen.
4. If asked for a password, enter the code “0000.”
5. The remote LCD screen will display, “BT AUDIO” if the process was successful.
G. Operating Your Bluetooth Device:
1. Press the seek up or down buttons to scroll through the tracks (on the remote).
2. Press the volume up or down buttons to adjust volume level between
0 to 30 (on the remote).
3. Any other playback operations are conducted via the Bluetooth device.
CAUTION : RISK OF ELECTRICAL SHOCK OR EQUIP-
MENT DAMAGE!
Never install, remove or operate any electrical device (e.g.
Apple device/MP3/USB/AUX/Bluetooth) while hands are wet or while sitting partially or fully immersed in the spa!
18.5 Wireless Remote Battery Replacement Procedure
1. Turn the remote unit over and locate the battery door
(Figure A).
Battery
Door
OPEN CLOSED
2. Rotate the battery door, with a coin, counterclockwise to the Open position (Figure B). When the door is unlocked it will pop up slightly.
OPEN
Fig. A
CLOSED
Fig. B
3. Remove battery door by lifting the door upward (Figure C).
OPEN CLOSED
OPEN
Fig. C
CLOSED
4. Replace battery using an equivalent battery (Figure D).
Fig. D
72
5. Reinstall the battery cover, using the coin rotate the door to the Close position (Figure E).
J-300
OPEN CLOSED
Note: Remote unit is water resistant not waterproof. Although it is
Fig. E designed for use while in the spa, it should never be left in the spa while the cover is on and spa is not in use. The remote should be stored in a dry location such as the stereo remote pouch (if applicable) located on the outside of the spa cover or within your home. Extreme weather can affect the remote control battery. In extreme hot or cold environments store the remote control indoors to prolong battery life.
18.6 BLUEWAVE® Spa Stereo System Specifications
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.7-14.4V DC
Tuner
FM radio sensitivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8uV
FM radio reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stereo
18.7 Stereo Cautions
1. “ CAUTION - Risk of Electric Shock. Do not leave compartment door open.”
2. “ CAUTION - Risk of Electric Shock. Replace components only with identical components.”
3. “Do not operate the audio/video controls while inside in the spa.”
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
4. “ WARNING - Risk of Electrocution. Do not connect any auxiliary components (for example cables, additional speakers, headphones, additional audio/video components, etc.) to the system.”
5. These units are not provided with an outdoor antennae; when provided, it should be installed in accordance with Article 810 of the
National Electrical Code, ANSI/NFPA 70.
6. Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel.
7. When the power supply connections or power supply cord(s) are damaged; if water is entering the audio/video compartment or any electrical equipment compartment area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the unit, turn off the unit and refer servicing to a qualified service personnel.
73
J-300
8. This unit should be subjected to periodic routine maintenance
(for example, once every 3 months) to make sure that the unit is operating properly.
74
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 Important Spa Owner Information
- 7 FCC Notice
- 8 Important Safety Instructions for all Spa Owners
- 12 Entrapment Risk
- 13 3.2 Hyperthermia
- 14 (Canada Only)
- 14 General Electrical Safety Instructions
- 15 Choosing A Location
- 16 Outdoor Location
- 16 Indoor Location
- 17 Remote Monitoring System
- 18 General Electrical Safety Instructions
- 19 Power Requirements
- 21 Electrical Wiring Instructions
- 26 Spa Fill Up Procedure
- 31 Control Functions
- 31 Control Panel
- 32 General Spa Features And Controls
- 33 10.0 Operating Instructions
- 33 10.1 Register Your New Spa
- 34 10.2 Completing Your Registration
- 34 10.3 Setting Water Temperature
- 35 10.4 Activate Jet Pumps
- 35 10.5 Light On/Off Button
- 35 10.6 Light Mode Button
- 36 10.7 Jets
- 36 10.8 Selecting Desired Massage Action
- 36 10.9 Waterfall Feature
- 36 RAY on Demand
- 37 10.11 Air Controls
- 37 10.12 Optional BLUEWAVE® Spa Stereo System
- 37 10.13. Blow-Out Cycle
- 37 10.14 Cleanup Cycle
- 38 11.0 Menu Features and Programming Instructions
- 38 11.1 Primary Filtration Menu
- 39 11.2 Secondary Filtration Menu
- 40 11.3 Programming the Heating Mode
- 41 11.4 Programming the Change Filter Timer
- 41 RAY Timer
- 42 11.6 Programming the Water Refresh Timer
- 42 11.7 Programming the Time
- 43 11.8 Programming the Date
- 43 11.9 Programming the Temperature Format
- 43 11.10 Programming the Language
- 44 11.11 Programming the Lock Feature
- 44 11.12 Resetting the Wi-Fi Connection (optional feature)
- 45 12.0 Spa Maintenance
- 45 12.1 Cleaning The Filters
- 48 12.2 Draining and Refilling
- 49 12.3 Pillow Care
- 49 12.4 Cleaning The Spa Interior
- 49 12.5 Cover Care and Maintenance
- 50 12.6 Tool Free Access Door
- 51 12.7 Maintaining The Synthetic Cabinet
- 51 12.8 Winterizing
- 52 12.9 Restarting Your Spa in Cold Weather
- 52 13.0 Water Quality Maintenance
- 53 13.1 pH Control
- 53 13.2 Sanitizing
- 54 RAY® (Ultraviolet) Water Purification System
- 55 Quartz Tube Maintenance
- 57 14.0 Error Conditions/Error Messages
- 57 14.1 Summer Logic
- 57 14.2 Panel Displays COOL
- 58 14.3 Panel Displays ICE
- 58 14.4 Panel Displays SN
- 58 14.5 Panel Displays SN
- 58 RAY Bulb
- 58 14.7 Panel Displays Change Filter
- 58 14.8 Panel Displays Change Water
- 59 14.9 Panel Displays FL
- 59 14.10 Panel Displays FL
- 59 14.11 Panel Displays OH
- 59 14.12 Panel Displays (-- -- -- --)
- 60 15.0 Troubleshooting Procedures
- 60 15.1 FL--1 and FL
- 60 15.2 None of the Components Operate (e.g. Pump, Light)
- 60 15.3 Pump Does Not Operate
- 61 15.4 Poor Jet Action
- 61 15.5 Water is Too Hot
- 61 15.6 No Heat
- 62 16.0 Circuit Board Diagrams
- 62 J-375 and J-385 Dedicated Power Models (60 Hz)
- 63 Models (For a 3-wire 120V 60 Hz connection)
- 64 Models (For a 4-wire 240V 60 Hz connection)
- 65 J-385 Models (50 Hz)
- 66 16.5 Export J-315 and J-325 Models (50 Hz)
- 67 17.0 Dip Switch Settings and Wiring
- 67 17.1 Switch settings for Domestic 60Hz Models
- 68 17.2 Switch settings for Export 50Hz Models
- 70 17.3 Single Service 50Hz Connection
- 70 17.4 Dual Service 50Hz Connection
- 71 17.5 Three Service 50Hz Connection
- 72 18.0 Optional BLUEWAVE® Spa Stereo System
- 73 18.1 Pairing the Remote and Stereo
- 73 18.2 Audio Settings
- 75 18.3 Wireless Remote Control Functions
- 76 18.4 Electronic Device Connections and Functions
- 78 18.5 Wireless Remote Battery Replacement Procedure
- 79 18.6 BLUEWAVE® Spa Stereo System Specifications
- 79 18.7 Stereo Cautions