Safety Instructions

. . . . . . . . . . .2

Operating Instructions

Air Direction . . . . . . . . . . . . . . . . .4

Auxiliary Controls . . . . . . . . . . .5–9

Controls . . . . . . . . . . . . . . . . . . . . .3

To Remove the Room Cabinet . .4

Vent Control . . . . . . . . . . . . . . . . .4

Care and Cleaning

Air Filters . . . . . . . . . . . . . . . . . . .11

Base Pan . . . . . . . . . . . . . . . . . . .10

Outdoor Coils . . . . . . . . . . . . . . .10

Room Cabinet and Case . . . . . . .10

Vent Filter . . . . . . . . . . . . . . . . . .10

Installation Instructions

Electrical Connection . . . . . .14–17

Installing the Zoneline . . . . .18, 19

Optional Drain Kit . . . . . . . . . . .20

Preparation . . . . . . . . . . . . . . . . .12

Replacing an Existing Unit? . . .13

Troubleshooting Tips

. . . . .21, 22

Normal Operating Sounds . . . . .23

Consumer Support

Consumer Support . . . .Back Cover

Warranty . . . . . . . . . . . . . . . . . . .27

ge.com

Owner’s Manual and

Installation Instructions

Heat/Cool Model 2800

Heat Pump Model 3800

Español

For a Spanish version of this manual, visit our Website at ge.com.

Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet ge.com.

Française

For a French version of this manual, visit our Website at www.electromenagersge.ca.

Pour une version française de ce manuel d'utilisation, veuillez visiter notre site web à l’adresse www.electromenagersge.ca.

Write the model and serial numbers here:

Model # ____________________

Serial # ____________________

Find these numbers on a label behind the room cabinet on the base pan.

TINSEA471JBRZ 49-7559-1

12-08 JR

2

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

SAFETY PRECAUTIONS

■ This Zoneline must be properly installed in accordance with the

Installation Instructions before it is used. See the Installation Instructions in the back of this manual.

■ Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired.

Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

■ Unplug or disconnect the Zoneline at the fuse box or circuit breaker before making any repairs.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

Replacing an existing unit?

For details, see the Installation

Instructions in this manual.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

About the controls on your Zoneline.

ge.com

TEMP CONTROL MODE CONTROL

Controls

Temp Control

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same comfort level. When you turn the knob to COOLER (blue), the indoor air will become cooler. Turn the knob to

WARMER (red) and the indoor air will become warmer.

3800 Series only

When the outdoor temperature is lower than 20°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump.

Mode Control

HIGH COOL and LOW COOL provide cooling with different fan speeds.

HIGH HEAT and LOW HEAT provide heating with different fan speeds.

LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating.

NOTE: If you move the switch from a cool or heat setting to STOP or to a fan setting, the unit has an automatic 3-minute delay before allowing the compressor to restart in the cool or heat mode.

About Your Heat Pump (3800 Series only)

Heat pumps can save money by removing heat from the outside air—even when the outside temperature is below freezing—and releasing that heat indoors.

To get the best performance from your heat pump, don’t change the room thermostat very often. Raising the heat setting 2–3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature setting quickly.

There is a three minute minimum compressor run time at any setting to prevent short cycling.

The indoor fan motor starts before the compressor and stops after the compressor cycles off.

The electric heating elements use much more electricity than heat pumps and cost more to operate.

Quick Heat Recovery

Activates each time the thermostat is switched from STOP or a COOL mode to a HEAT mode. Electric heaters are energized until the thermostat set point is reached. On heat pump models, the heat pump operation will resume at the next call for heat.

3

Other features of your Zoneline.

Ventilation Control

The ventilation control lever is located at the upper left side of the Zoneline unit, behind the room cabinet.

When set at the closed position, only the air inside the room is circulated and filtered.

When set at the open position, some outdoor air will be drawn into the room. This will reduce the heating or cooling efficiency.

Energy Tip: Keep the vent control at the closed position. The room air will be filtered and circulated.

NOTE: Two shipping screws must be removed from the vent door before use. See the Installation Instructions in the back of this manual.

Open position

Vent control

(shown in middle position)

Closed position

To Remove the Room Cabinet

Additional controls are located behind the room cabinet.

To remove: Pull out at the bottom to release it from the tabs (1). Then lift up (2).

To replace: Place the tabs over the top rail (1).

Push inward at the bottom until it snaps into place (2).

4

Air Direction

To adjust the air direction, remove the room cabinet. Remove the 7 louver screws that hold the louver insert in place. Flip the louver insert

180°, replace the screws and the room cabinet.

Louver screws

Remove the room cabinet and flip the louver insert to change the air direction.

Louver screws

Auxiliary Controls on your Zoneline.

Auxiliary Controls—Dip Switches

The auxiliary dip switch controls are located behind the room cabinet, through an opening in the control panel.

Remove the room cabinet. See the To Remove the

Room Cabinet section.

The owner is responsible for checking switches and ensuring they are in the desired position.

ge.com

Dip Switches

Access Cover

ALLI 2 R (All Electric Heat)

(3800 Series models only)

C: FAN CN (Cooling–Smart Fan)

H: FAN CY (Heating–Smart Fan)

CLASS 2 (Remote Thermostat)

LOAD SHEDDING (CDC)

FREEZ Sen (Freeze Sentinel)

CONST FAN (Constant ON Fan)

No Function (Reserved for future use)

UP

DOWN

1 2 3 4 5 6 7 8 1 2 3

HIGH

COOL

6 7 8

UP

DOWN

HEAT BOOST

(3800 Series models only)

Heat Sentinel

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)

TL3 (H) (Temp. Limit 3–Heat)

TL1 (C) (Temp. Limit 1–Cool)

TL2 (C) (Temp. Limit 2–Cool)

TL3 (C) (Temp. Limit 3–Cool)

All Electric Heat

This electric heat option functions only on the

3800 Series models. When this switch is enabled

(UP), heat pump operation is locked out, causing the unit to provide only electric resistance heat.

ALLI 2 R (All Electric Heat)

Cooling—Smart Fan

When this switch is enabled (UP), it allows the indoor fan to cycle on/off with the compressor.

When this switch is disabled (DOWN), it allows the indoor fan to run continuously.

Heating—Smart Fan

When this switch is enabled (UP), it allows the indoor fan to run continuously. When this switch is disabled (DOWN), it allows the indoor fan to cycle on/off with the heat pump or heater operation.

C: FAN CN (Cooling–Smart Fan)

H: FAN CY (Heating–Smart Fan)

5

Auxiliary controls on your Zoneline.

Remote Thermostat—Class 2

When this switch is enabled (UP), it allows the unit to operate with a Class 2 Remote Control

Wall Thermostat. The unit controls are disabled.

Load Shedding (Central Desk Control)

This feature is active only if the unit is in

CDC mode. When this switch is enabled (UP), the indoor fan can be turned ON or OFF with the unit controls.

Freeze Sentinel

When this switch is enabled (UP), it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN), the freeze sentinel is activated, which automatically provides heat without user interface. This helps to prevent plumbing damage by turning the heater and indoor fan ON at 41°F and OFF at 46°F.

Constant ON Fan

When this switch is enabled (UP), it allows the indoor fan to run continuously, at high speed, even if the unit is in the STOP position.

CLASS 2 (Remote Thermostat)

LOAD SHEDDING (CDC)

FREEZE Sen (Freeze Sentinel)

CONST FAN (Constant

ON Fan)

6

ge.com

Temperature Limiting

Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. Temperature limiting is controlled by the second six auxiliary switches.

The first three switches are used to select the cooling limits, and the remaining three switches are used to control the heating limits. This feature is not available with the Remote

Thermostat—Class 2.

UP

DOWN

1 2 3 4 5 6 7 8

TL1 (C) (Temp. Limit 1–Cool)

TL2 (C) (Temp. Limit 2–Cool)

TL3 (C) (Temp. Limit 3–Cool)

1 2 3

HIGH

COOL

6 7 8

UP

DOWN

UP

DOWN

1 2 3 4 5 6 7 8 1 2 3

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)

TL3 (H) (Temp. Limit 3–Heat)

HIGH

COOL

6 7 8

UP

DOWN

Temperature limiting during COOL mode

(all temperatures shown in °F)

UP

NONE

DOWN

1, 2, 3

Minimum

60°

Maximum

85°

1

1, 2

2

2, 3

2, 3

3

1, 3

1

64°

66°

68°

70°

85°

85°

85°

85°

1, 2, 3

1, 3

3

NONE

2

1, 2

72°

74°

76°

85°

85°

85°

Temperature limiting during HEAT mode

(all temperatures shown in °F)

UP

NONE

DOWN

4, 5, 6

Minimum

60°

Maximum

85°

4

4, 5

5

5, 6

5, 6

6

4, 6

4

60°

60°

60°

60°

80°

78°

76°

74°

4, 5, 6

4, 6

6

NONE

5

4, 5

60°

60°

60°

72°

70°

65°

Heat Sentinel

When this switch is enabled (UP), it turns ON the heat sentinel protection feature. With the switch disabled (DOWN), the heat sentinel is de-activated. This feature automatically provides cooling without user interface. This helps to prevent an excessively hot room by turning the air conditioner ON at 85°F and OFF at 80°F.

Heat Boost

(AZ3800 only)

When this switch is enabled (UP) and outdoor temperatures are between 20°F and 46°F, heat pump only operation is locked out. This setting is used to provide supplementary heat to the heat pump operation in conditions where the heat pump only operation is not sufficient to maintain a consistent, comfortable room temperature.

NOTE: This is an auxiliary switch for AZ2800 models and must remain in the (DOWN) position.

Heat Sentinel

BOOST (Heat Boost Operation)

7

Auxiliary controls on your Zoneline.

Auxiliary Controls—Terminal Connections

The auxiliary controls are located behind the room cabinet beneath the access cover.

1

Remove the room cabinet. See the

To Remove the Room Cabinet section.

2

3

Remove the screw from the access cover.

To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely.

4

After all desired connections have been made, replace the access cover and room cabinet.

The owner is responsible for making all connections and setting the appropriate dip switches.

CAUTION:

Improper wiring may damage the Zoneline electronics. No common busing is permitted.

Damage or erratic operation may result.

A separate wire pair must be run from each separate controlling switch to each individual

Zoneline.

External Fan

Central Desk Control

Common - Ground

White - Heater

Yellow - Compressor

Black - Solenoid

Green - High Speed Fan

Green - Low Speed Fan

Red - 24 V AC only

8

ge.com

External Fan (Obtained locally)

When connected, an auxiliary or external fan can be controlled with the indoor fan motor on the Zoneline. Connections provide 24 V AC to energize a remote relay, turning on the external fan.

External Fan

Central Desk Control

When connected, the unit can be turned ON or OFF with a switch located at the Central

Control Panel. A separate wire pair must be run from each separate controlling switch to each individual Zoneline.

Central Desk Control

Remote Thermostat

When connected, the unit will be controlled by a remote thermostat.

NOTE: The number 4 dip switch must be in the enabled (UP) position to activate the remote thermostat. (See the installation instructions supplied with the remote thermostat).

IMPORTANT:

The Zoneline thermostat connections provide 24 V AC only.

If using a digital/electronic wall thermostat, you must set it to the 24 V AC setting.

See the Installation Instructions for the wall thermostat.

Red - 24 V AC only

Green - Low Speed Fan

Green - High Speed Fan

Black - Solenoid

Yellow - Compressor

White - Heater

Common - Ground

CAUTION:

Damage to a wall thermostat or to the

Zoneline electronics can result from improper connections. Special care must be used in connecting the wires. No line voltage connections should be made to any circuit.

Isolate all wires in building from line voltage.

9

Care and cleaning.

Room Cabinet and Case

Turn the Zoneline off and disconnect the power supply.

To clean, use water and a mild detergent.

Do not use bleach or abrasives. Some commercial cleaners may damage the plastic parts.

Outdoor Coils

The coils on the outdoor side of the Zoneline should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your

GE service outlet. You will need to remove the unit to inspect the coils because the dirt buildup occurs on the inside.

Coils

Grille

Clean the outside coils regularly.

Base Pan

In some installations, dirt or other debris may be blown into the unit from the outside and settle in the base pan (the bottom of the unit).

In some areas of the United States, a “gel-like” or

“slime-like” substance may be seen in the base pan.

Check it periodically and clean, if necessary.

Ventilation Filter

If the vent door is open, clean the vent filter twice a year or as required.

Turn the Zoneline off before cleaning.

To remove the vent filter:

■ Remove the room cabinet. See the To Remove the Room Cabinet section.

■ Remove the four screws securing the unit flanges to the case.

■ Slide the unit from the wall case.

■ Grasp the vent filter tab and pull the filter out by sliding it to the right.

To clean the vent filter:

■ Run water through the filter from the back side.

■ Dry thoroughly before replacing.

10

ge.com

To maintain optimum performance, clean the filters at least every 30 days.

Air Filters

To remove the air filters:

FRONT

FRONT

2 Air filters

Pull up

Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow.

Turn the Zoneline off before cleaning.

The most important thing you can do to maintain the Zoneline is to clean the filter at least every 30 days. Clogged filters reduce cooling, heating and air flow.

Keeping these filters clean will:

■ Decrease cost of operation.

■ Save energy.

■ Prevent clogged heat exchanger coils.

■ Reduce the risk of premature component failure.

To clean the air filters:

■ Vacuum off the heavy soil.

■ Run water through the filters from the back side.

■ Dry thoroughly before replacing.

NOTE: The air filters are interchangeable and will fit in either the right or left side.

To replace the air filters:

Push down

CAUTION:

Do not operate the

Zoneline without the filters in place. If a filter becomes torn or damaged, it should be replaced immediately.

Operating without the filters in place or with damaged filters will allow dirt and dust to reach the indoor coil and reduce the cooling, heating, airflow and efficiency of the unit.

Replacement filters are available from your salesperson, GE dealer, GE Service and Parts

Center or authorized Customer Care ® servicers.

11

Installation

Instructions

Zoneline Air

Conditioners

Questions? Call 800.GE.CARES (800.432.2737) or

visit our Website at:

ge.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT –

Save these instructions for local inspector’s use.

IMPORTANT –

Observe all governing codes and ordinances.

Note to Installer –

Be sure to leave these instructions with the owner.

Note to Owner –

Keep these instructions for future reference.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

TOOLS YOU WILL NEED

Phillips screwdriver

IMPORTANT ELECTRICAL

SAFETY—READ CAREFULLY

CAUTION:

• Follow the National Electrical Code (NEC) or local codes and ordinances.

• For personal safety, this Zoneline must be properly grounded.

• Protective devices (fuses or circuit breakers) acceptable for Zoneline installations are specified on the nameplate of each unit.

• Do not use an extension cord with this unit.

• Aluminum building wiring may present special problems—consult a qualified electrician.

• When the unit is in the OFF position, there is still voltage to the electrical controls.

• Disconnect the power to the unit before servicing by:

1 Removing the power cord (if it has one) from the wall receptacle.

OR

2 Removing the branch circuit fuses or turning the circuit breakers off at the panel.

ZONELINE COMPONENTS

Zoneline unit

Room cabinet*

Power supply kit**

Exterior grille/louver**

Wall case**

* * Shipped with the Zoneline unit

** Check the “Essential Elements” list on the unit

12

Installation Instructions

REPLACING AN EXISTING UNIT?

Check the “Essential

Elements” label for important information.

Replacing a ducted unit

New ducted installation:

If this unit is to be installed in a new ducted application using a duct adapter kit, the kit must be installed before the unit is placed in the wall case. The installation instructions are packed with the kit.

Mounting plate

Duct

Use the correct wall case

This unit is designed to be installed in a GE plastic or insulated metal wall case. This minimizes condensation from forming on the room side of the case.

If the current wall case is not insulated, you can reduce the possibility of condensation forming by installing insulation kit RAK901L, available where you purchased the unit.

NOTE:

There are several extra holes in the unit side flanges for installation in wall cases other than GE.

To avoid damaging the flange insulation, the installer should use an awl or other sharp tool to puncture the insulation in the appropriate holes before installing the attachment screws.

Use the correct outdoor grille

You should use the outdoor grilles shown on the

“Essential Elements” label on the top of the unit.

If an existing grille is not replaced, capacity and efficiency will be reduced and the unit may fail to operate properly or fail prematurely. A deflector kit,

RAK40, may be used with grilles that were not designed for your new GE Zonelines. The RAK40 contains air deflectors and gaskets that mount to the unit to direct the hot exhaust air away from the air intake to allow the unit to function properly. The grille must have a 65% minimum free area.

Any vertical deflectors in the existing rear grille should be removed to decrease condenser air recirculation that can cause the unit to “short-cycle” and lead to premature component failure.

Use the correct power cord

Local codes may require the use of arc fault or leakage current detection devices on 230/208 volt installations.

Case

Existing ducted installation:

Replacement of an existing ducted unit may require different components. Request this information from your sales representative.

• Replacing 230/208 volt units:

See page 14.

• Replacing 265 volt units:

See pages 15 and 16.

13

Installation Instructions

230/208 VOLT ELECTRICAL CONNECTION OPTIONS

HOW TO CONNECT

1 Remove the room cabinet.

2 Connect to electrical power.

3 Review the following steps for applicable supply voltages.

4 Reinstall the room cabinet.

Power cords may include an arc fault interruption or a leakage current detection interruption device. A test and reset button is provided on the plug case or the inline case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the Zoneline and contact a qualified service technician.

POWER CORD

CONNECTION

A power supply kit must be used to supply power to the

Zoneline unit. The appropriate kit is determined by the voltage, the means of electrical connection and the amperage of the branch circuit.

Power supply kit

Connections of 208 or 230 volt circuits may be with a power supply kit or a junction box kit.

All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations. Local codes may require the use of an arc fault or leakage current detection device on the power cord. Be sure to select the correct cord for your installation.

ELECTRICAL SUBBASE

CONNECTION

230/208 volt models may be installed using one of the following electrical subbases:

Branch Circuit and

Unit Amperage Rating

15

20

30

Proper GE

Subbase Kit

RAK204D15P

RAK204D20P

RAK204D30P*

*Not approved for use on 7000 BTU models.

Electrical subbases provide an enclosure for direct connection or enclosed receptacles. The subbase kit includes the power cord.

The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.

Tandem

15 Amp.

Perpendicular

20 Amp.

Large Tandem

30 Amp.

230/208 volt receptacle configuration.

Branch Circuit and

Unit Amperage Rating

15

20

30

Proper GE Power Cord with LCDI Device

RAK3153

RAK3203

RAK3303*

*Not approved for use on 7000 BTU models.

DIRECT CONNECTION

Order the following Kit for 230/208 volt direct connection as required:

Branch Circuit and

Unit Amperage Rating

15

20

30

Power Supply

Accessory

RAK4002A

RAK4002A

RAK4002A

Power

Supply Kit

RAK4157

RAK4207

RAK4307

Skip to the “MAKE ELECTRICAL CONNECTION TO

THE UNIT” section.

14

Installation Instructions

265 VOLT ELECTRICAL CONNECTION OPTIONS

WARNING:

Connection of this 265 V AC product to a branch circuit

MUST

be done by direct connection in accordance with the National Electrical Code. Plugging this unit into a building mounted exposed receptacle is not permitted by code.

These models must be installed using the appropriate

GE power supply kit for the branch circuit amperage and the electrical resistance heater wattage desired.

Use the POWER CONNECTION CHART on page 17 to determine the correct kit required. One of the following installation methods (A or B) must be used.

B. FOR DIRECT CONNECT

INSTALLATION

If an electrical subbase is not used, direct connection to branch circuit wiring inside the provided junction box must be done in accordance with the following steps.

Order the following Kit for 265 volt direct connection as required:

Branch Circuit and

Unit Amperage Rating

15

20

30

Power

Supply Kit

RAK5157

RAK5207

RAK5307

Proceed to the “MAKE ELECTRICAL CONNECTION

TO THE UNIT” section.

A. FOR SUBBASE INSTALLATION

Electrical subbase kits are available to provide a flexible enclosure for direct connection.

Branch Circuit and

Unit Amperage Rating

15

20

30

Proper GE

Subbase Kit

RAK204E15

RAK204E20

RAK204E30

Power

Supply Kit

RAK5172

RAK5202

RAK5302

The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.

15

Installation Instructions

MAKE ELECTRICAL CONNECTION TO THE UNIT

1

REMOVE JUNCTION BOX

1 Remove the junction box cover by removing the front two screws.

2 Remove the junction box by removing the top and bottom rear screws. Note how the tabs on the lower left side of the junction box serve to hold the side in place. This will help when the box is being reinstalled.

Unit connector

3

ATTACH CONDUIT

1 Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout, attach the conduit and bring wires into the junction box.

Leave 6

″ of wire free at the end of the conduit to allow connections to be made.

Junction box cover

Junction box

2

CONNECT THE CORDSET

Plug the connector, provided in the Direct Connect

Kit, fully into place in the unit mating connector.

Be sure the locking tabs at the sides are engaged.

Connector

NOTE:

Order Kit RAK4002CW to enable a quick disconnect inside the junction box.

Conduit

2 If a fuse and fuseholder are to be used, the knockout at the top of the box is for mounting a Buss Fuseholder. Be sure the fuse and fuseholder are of the same rating as the branch circuit.

Leadwires at the fuse can be either soldered in place or attached using UL-listed 1/4

″ female

(receptacle) crimp connectors.

4

REINSTALL JUNCTION BOX

Reinstall the junction box by engaging the left tabs on the lower right face of the unit, aligning the screw holes at the top and bottom and driving the two screws until secure. Be sure that all wire leads are inside the box and not pinched between the box and the unit. The green insulated ground wire from the unit MUST be connected to the branch circuit ground wire.

Make all wire connections by using appropriate

UL-listed electrical connectors and techniques

(black to black, white to white and green to green).

5

REINSTALL JUNCTION BOX COVER

1 Carefully tuck all wires and connections back inside the junction box. Be sure there are no loose connections or stray uninsulated wires exposed.

2 Place the junction box cover in place. Replace the two screws removed earlier and tighten securely.

16

Installation Instructions

POWER CONNECTION CHART

Power Cord Connections

230/208 Volt

Power Supply Kits with Current Leakage

Detection Device

RAK3153

RAK3203

RAK3303*

Wall Plug

Configuration

Tandem

Perpendicular

Large Tandem

Circuit Protective Device

15 Amp Time-Delay Fuse or Breaker

20 Amp Time-Delay Fuse or Breaker

30 Amp Time-Delay Fuse or Breaker

Heater Wattage

@ 230/208 Volts

2.55/2.09 KW

3.45/2.82 KW

5.00/4.10 KW

230/208 Volt

Power Supply Kits

RAK4157

RAK4207

RAK4307

265 Volt

Power Supply Kits

RAK5172

RAK5202

RAK5302*

* Not approved for use on 7000 BTUH units.

Direct Connections

Heater Wattage

@ 230/208 Volts

2.55 KW/2.09 KW

3.45 KW/2.82 KW

5.00 KW/4.10 KW

Heater Wattage

@ 265 Volts

2.55 KW

3.45 KW

5.00 KW

Circuit Protective Device

15 Amp Time-Delay Fuse or Breaker

20 Amp Time-Delay Fuse or Breaker

30 Amp Time-Delay Fuse or Breaker

Circuit Protective Device

15 Amp Time-Delay Fuse or Breaker

20 Amp Time-Delay Fuse or Breaker

30 Amp Time-Delay Fuse or Breaker

17

Installation Instructions

INSTALLING THE ZONELINE

1

INSTALL THE WALL CASE AND

EXTERIOR GRILLE

The RAB71 series or RAB77 wall case must be properly installed per instructions packed with the case.

Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out.

Protective panel

Slit

2

PREPARE THE UNIT

Carefully remove shipping tape and foam shipping blocks from the room cabinet, compressor and vent door. There may be multiple blocks and pieces of shipping tape that need to be removed.

Shipping tape

(Locations may vary)

Remove the room cabinet by pulling it out at the bottom to release it (1), then lift it up to clear the rail along the unit top (2).

Stiffener

Install the exterior grille from the room side following instructions packed with the grille.

Insulated Wall Case

This unit is designed to be installed in a GE plastic or an insulated steel wall case. This minimizes condensation from forming on the room side of the case.

The RAB71 series wall cases are insulated. Insulation kit RAK901L is available for use with RAB77 or existing uninsulated wall cases when needed.

NOTE:

For installation with a subbase or duct adapter, see the instructions packed with those kits.

If vent door is to be operational, remove shipping screws from the front side of the vent door, if present.

Remove two shipping screws

18

Installation Instructions

3

INSTALL THE UNIT INTO THE

WALL CASE

Slide the unit into the wall case and secure with four screws through the unit flange holes.

4

REPLACE THE ROOM CABINET

Reinstall the room cabinet by hooking the top over the rail along the unit top (1), then pushing it in at the bottom (2).

NOTE:

There are several extra holes in the unit side flanges for installation in wall cases other than GE.

To avoid damaging the flange insulation, the installer should use an awl or other sharp tool to puncture the insulation in the appropriate holes before installing the attachment screws.

19

Installation Instructions

OPTIONAL—DRAIN KIT INSTALLATION

Dry Air 25 Series models are designed to improve dehumidification by 25%. Since more moisture will be removed from the air, there is a greater possibility that water will drip from the wall case than with a standard unit. To prevent this water from dripping onto external building walls, we recommend the use of RAD10 Drain Kit.

External Drain

See the Installation Instructions in the RAD10 kit.

Alternate:

6

″ long, 1/2″ O.D. straight copper tube

Internal Drain

See the Installation Instructions in the RAD10 kit.

Square drain holes

1/2

″ O.D. drain tube

Neoprene sponge gasket

Steel mounting plate

Type “A” screw for metal case or

Type “B” screw for molded case

Square drain holes

Neoprene sponge gasket

Steel mounting plate

Type “A” screw for metal case or

Type “B” screw for molded case

20

Before you call for service…

Troubleshooting Tips

Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem

Zoneline does not start

Possible Causes

The unit is unplugged.

The power cord is not firmly attached.

The fuse is blown/circuit breaker is tripped.

The unit is waiting for the compressor overload protector to reset.

Power failure.

The current interrupter device is tripped.

Zoneline does not cool or heat as it should

Indoor airflow is restricted.

Outdoor airflow is restricted or recirculated.

The temp control may not be set properly.

The air filter is dirty.

The room may have been hot or cold.

Outdoor air is entering the room.

Burning odor at the start

Dust is on the surface of heating operation of the heating element.

ge.com

What To Do

• Make sure the Zoneline plug is pushed completely into the outlet.

• Remove the room cabinet and make sure that the yellow connector on the end of the power cord is firmly engaged.

• Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.

• This is normal. The Zoneline will start again after it resets.

• If power failure occurs, set the mode control to STOP.

When power is restored, set the mode control to the desired setting.

• There is a protective time delay (up to 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal heating or cooling for 3 minutes after it is turned back on.

• Press the RESET button located on the power cord plug or the box near the plug.

• If the RESET button will not stay engaged, discontinue use of the Zoneline and contact a qualified service technician.

• Make sure there are no curtains, blinds or furniture blocking the front of the Zoneline.

• Make sure the rear grille is not restricted. This can cause the unit to cycle off due to the compressor overload protector.

• Outdoor grille must have a minimum of 65% free area.

Non-GE grilles may be too restrictive for proper performance. Consult your salesperson for assistance.

• Turn the control to a lower or higher setting.

NOTE: The temperature limiter may be limiting the temperature range.

• Clean the filter at least every 30 days.

See the Operating Instructions section.

• When the Zoneline is first turned on you need to allow time for the room to cool down or warm up.

• Set the vent control to the closed position.

• This can cause a “burning” odor at the beginning of the heating operation. This odor should quickly fade.

21

Before you call for service…

Problem

The air is not always cool or hot during operation

Possible Causes

The heat pump is not producing hot air.

The fan switches may be set at continuous fan.

The air does not feel warm enough during heating operation

The heat pump alone produces air that feels cooler than desired.

The unit is not blowing out air

The fan dip switch may be set to CYCLE.

The electric heating

The power cord is not feature does not work firmly attached.

What To Do

• This is normal. The heat pump will produce warm air but not as hot as air produced when the higher-cost electric heat is used.

• This causes the fan to blow room temperature air even when the compressor or heater cycles off.

The continuous air movement provides better overall temperature control in the cool mode.

• There is one switch for cooling and one switch for heating.

• Use the Electric Heat Option. This turns off the heat pump and warms with electric heat only.

NOTE: Use of this option will result in increased energy consumption.

• See the Auxiliary Controls section.

• Remove the room cabinet and make sure that the yellow connector on the end of the power cord is firmly engaged.

22

Things that are normal.

ge.com

Normal Operating Sounds

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

“CLICK”

You may hear relays click when the controls cycle on and off or are adjusted to change the room temperature.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

The indoor fan runs continuously when the unit is operating in the cooling mode, unless the fan switch behind the room cabinet is set at fan cycle (up).

This will cause the fan to cycle on and off with the compressor. You may also hear a fan noise stop and start.

S

I L E N C E

You may notice a few minutes delay in starting if you try to restart the Zoneline too soon after turning it off or if you adjust the thermostat right after the compressor has shut off. This is due to a built-in restart protector for the compressor that causes a 3-minute delay.

During the defrost cycle, both indoor and outdoor fans stop and the compressor will operate in the cooling mode to remove frost from the outdoor coil.

After defrost, the unit will restart in electric heat to quickly warm the room to the desired comfort level.

COMPRESSOR

PROTECTION

To protect the compressor and prevent short cycling, the unit is designed to run for a minimum of 3 minutes after the compressor starts at any thermostat setting.

23

Notes.

24

Notes.

ge.com

25

Notes.

26

Zoneline Warranty.

All warranty service provided by our Factory Service Centers, or an authorized Customer Care

® technician. To schedule service, on-line, visit us at ge.com, or call 800.GE.CARES

(800.432.2737). For service in Canada, contact Gordon Williams

Corp. at 1.888.209.0999. Please have serial number and model number availa ble when calling for service.

For The Period Of: GE Will Replace:

One Year

From the date of the original purchase

Five Years

From the date of the original purchase

Five Years

From the date of the original purchase

Staple your receipt here.

Proof of the original purchase date is needed to obtain service under the warranty.

Any part of the Zoneline which fails due to a defect in materials or workmanship. During this

limited one-year warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.

Any part of the sealed refrigerating system (the compressor, condenser, evaporator and all connecting tubing) which fails due to a defect in materials or workmanship. During this

four-year limited additional warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.

For the second through the fifth year from the date of original purchase, GE will replace

certain parts that fail due to a defect in materials or workmanship. Parts covered are fan motors, switches, thermostats, heater, heater protectors, compressor overload, solenoids, circuit boards, auxiliary controls, thermistors, frost controls, ICR pump, capacitors, varistors and indoor blower bearing. During this four-year limited additional warranty, you will be responsible for any labor or on-site service costs.

What GE Will Not Cover:

Service trips to your site to teach you how to use

the product.

Improper installation, delivery or maintenance.

If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

In commercial locations, labor necessary to move the

unit to a location where it is accessible for service by an individual technician.

Failure or damage resulting from corrosion due to

installation in an environment containing corrosive chemicals.

Replacement of fuses or resetting of circuit breakers.

Failure of the product resulting from modifications

to the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance.

Failure or damage resulting from corrosion due to

installation in a coastal environment, except for models treated with special factory-applied anti-corrosion protection as designated in the model number.

Damage to product caused by improper power supply

voltage, accident, fire, floods or acts of God.

Incidental or consequential damage to personal property

caused by possible defects with this air conditioner.

Damage caused after delivery.

Product not accessible to provide required service.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited

Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for use within the USA and Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an

Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your site.

Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province. To know what your legal rights are, consult your local, state or provincial consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

27

Consumer Support.

GE Appliances Website

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.

ge.com

Schedule Service

ge.com

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

Real Life Design Studio

ge.com

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call

800.TDD.GEAC (800.833.4322).

Parts and Accessories

ge.com

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Contact Us

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Appliances, Appliance Park

Louisville, KY 40225

ge.com

Register Your Appliance

Register your new appliance on-line—at your convenience!

Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise.

You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner’s Manual.

ge.com

Printed in China

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals