American Standard Freedom 95 Gas-Fired Furnace User Manual
Below you will find brief information for Freedom 95 AUH2B060A9V3VA, Freedom 95 ADH2B060A9V3VA, Freedom 95 AUH2B080A9V3VA, Freedom 95 ADH2B080A9V3VA, Freedom 95 AUH2C100A9V4VA, Freedom 95 ADH2C100A9V4VA, Freedom 95 AUH2D120A9V5VA, Freedom 95 ADH2D120A9V5VA. This gas-fired furnace features a variable-speed blower motor, a silicon nitride igniter, and a variable-speed induced draft blower. It offers direct/non-direct vent options and is convertible to horizontal on left side.
Advertisement
Advertisement
Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace Freedom 95 AUH2B060A9V3VA, ADH2B060A9V3VA AUH2B080A9V3VA, ADH2B080A9V3VA AUH2C100A9V4VA, ADH2C100A9V4VA AUH2D120A9V5VA, ADH2D120A9V5VA Direct Vent with Variable Speed Blower Variable Speed Inducer *DH-A9V-V *UH-A9V-V DOWNFLOW UPFLOW UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL PUB. NO. 12-1272-03 General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./ Humidifier. © 2008 Trane All Rights Reserved 2 AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. SECONDARY HEAT EXCHANGER The Freedom 95 has a special type 29-4C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost instead. STYLING Heavy gauge steel and “wraparound” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The Freedom 95 High Efficiency Gas Furnaces utilize an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. Pub. No. 12-1272-03 Contents General Features Features and Benefits 2 4 Standard Equipment Optional Equipment 4 4 General Data 6-7 AUH2B060A9V3VA AUH2B080A9V3VA AUH2C100A9V4VA AUH2D120A9V5VA ADH2B060A9V3VA ADH2B080A9V3VA ADH2C100A9V4VA ADH2D120A9V5VA Performance Data Venting Tables Electrical Data Field Wiring Dimensions Pub. No. 12-1272-03 3 8-9 16 17-18 19-20 21-22 Features and Benefits FREEDOM 95 STANDARD EQUIPMENT • Variable Speed Blower Motor • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blower • Direct/Non-Direct vent option • Fused 24 volt control circuit • Manual reset burner safety switches • Power supply 115/1/60 • Convertible to horizontal on left side • 2-stage gas valve • PVC venting-1 or 2 pipe option • Accessory hook-up capability • Integrated solid state control with self-diagnostics • Attractive color accents • Heavy gauge aluminized steel heat exchanger • Multi-port In-shot burners • Quiet induced draft blower • Lite Port™ extended system diagnostics • Stored fault code history in micro processor nonvocatile memory 4 • Cleanable high velocity filters (upflow only) • Hinged blower door * • Perfect fit door latches* • Insulated blower door* • Gasketed blower door* • Complete front service access • Left/right gas connection • Adjustable fan off times • Optional L.P conversion kit • Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit • Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) • 5 Year limited parts warranty * (Upflow only) Pub. No. 12-1272-03 Features and Benefits FREEDOM 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ............................................................................................................. TAYSTAT241 [ Thermostat, Media Programmable 2-Stage Heating .............................................................................................. TAYSTAT302C [ Thermostat, Mechanical Heating Only With Fan Switch .......................................................................................... TAYSTAT303C [ Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................ AY28X092 [ Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................ BAYSTAT305 [ Thermostat, Media Programmable 1-Stage Heating/1-Stage Cooling ................................................................... TAYSTAT300C [ Propane Conversion Kit ........................................................................................................................................ BAYLPKT210A [ Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ...................................................... TFE145A9FR0 [ Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ...................................................... TFE175A9FR0 [ Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................ TFE210A9FR0 [ Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ...................................................... TFE245A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .............................................................. TFM145A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .............................................................. TFM175A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) .................................................................... TFM210A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .............................................................. TFM245A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ....................................................... TFP145A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ....................................................... TFP175A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ............................................................. TFP210A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ....................................................... TFP245A9FR0 [ Coil Enclosure (14-1/2" Wide Cabinets) ......................................................................................................... BAYCLE14A1422A [ Coil Enclosure (17-1/2" Wide Cabinets) ......................................................................................................... BAYCLE17A1722A [ Coil Enclosure (21" Wide Cabinets) ............................................................................................................... BAYCLE21A2130A [ Coil Enclosure (24-1/2" Wide Cabinets) ......................................................................................................... BAYCLE24A2430A [ Downflow Subbase ................................................................................................................................................. BAYBASE205 [ Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [ Filter Kit/Horizontal Conversion AUH2-060,080 ....................................................................................................... BAYFLTR203 [ Filter Kit/Horizontal Conversion AUH2-100 .............................................................................................................. BAYFLTR204 [ Filter Kit/Horizontal Conversion AUH2-120 .............................................................................................................. BAYFLTR205 [ High Altitude Pressure Switch Kit AUH2B060 ............................................................................................ BAYSWT10AHALTA1 [ High Altitude Pressure Switch Kit AUH2B080,C100,D120 ........................................................................ BAYSWT08AHALTA1 [ Concentric Vent Kit AUH2 Furnaces ............................................................................................................... BAYAIR30AVENTA [ Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces ............................................................................. BAYVENT200B [ Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces ........................................................................ BAYMFGH100A [ Cleanable Filter (14.5"/17.5" wide Upflow models) .................................................................................................. BAYFLTR317 [ Cleanable Filter (21" wide Upflow models) .............................................................................................................. BAYFLTR321 [ Cleanable Filter (24.5" wide Upflow models) ........................................................................................................... BAYFLTR324 [ AccuClean™, Whole House Air Cleaner (Upflow 14-1/2" Wide Gas Furnace) ........................................ AFD145ALFR000B [ AccuClean™, Whole House Air Cleaner (Upflow 17-1/2" Wide Gas Furnace) ......................................... AFD175ALFR000B [ AccuClean™, Whole House Air Cleaner (Upflow 21" Wide Gas Furnace) ................................................ AFD210ALFR000B [ AccuClean™, Whole House Air Cleaner (Upflow 24-1/2" Wide Gas Furnace) ......................................... AFD245ALFR000B [ AccuClean™, Whole House Air Cleaner (Downflow 14-1/2" Wide Gas Furnace) .................................... AFD14DALFR000B [ AccuClean™, Whole House Air Cleaner (Downflow 17-1/2" Wide Gas Furnace) .................................... AFD17DALFR000B [ AccuClean™, Whole House Air Cleaner (Downflow 21" Wide Gas Furnace) .......................................... AFD21DALFR000B [ AccuClean™, Whole House Air Cleaner (Downflow 24-1/2" Wide Gas Furnace) .................................... AFD24DALFR000B [ AccuClean™, Whole House Upgrade Kit (Upflow 14-1/2" Wide Gas Furnace) ...................................... AFD145ALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Upflow 17-1/2" Wide Gas Furnace) ...................................... AFD175ALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Upflow 21" Wide Gas Furnace) ............................................. AFD210ALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Upflow 24-1/2" Wide Gas Furnace) ...................................... AFD245ALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Downflow 14-1/2" Wide Gas Furnace) ................................. AFD14DALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Downflow 17-1/2" Wide Gas Furnace) ................................. AFD17DALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Downflow 21" Wide Gas Furnace) ....................................... AFD21DALUPGRDA [ AccuClean™, Whole House Upgrade Kit (Downflow 24-1/2" Wide Gas Furnace) ................................. AFD24DALUPGRDA [ AccuClean™, Whole House Transformer Kit (120 to 24 Volt - all TFD Air Cleaners) .................................. BAYTRANS12024 [ 1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. Pub. No. 12-1272-03 5 ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] General Data AUH2 PRODUCT SPECIFICATIONS1 Product Specifications 1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUH2B060A9V3VA Upflow / Horizontal AUH2B080A9V3VA Upflow / Horizontal AUH2C100A9V4VA Upflow / Horizontal AUH2D120A9V5VA Upflow / Horizontal 39,000 37,700 60,000 58,000 96.7 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 17x25 - 1 in. 2 Round 52,000 49,500 80,000 76,000 95 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 17x25 - 1 in. 2 Round 65,000 61,750 100,000 95,000 95 35 - 65 DIRECT 10 x 10 1 Variable See Fan Performance Table 3/4 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 20x25 - 1 in. 3 Round 78,000 74,500 120,000 114,700 95.6 40 - 70 DIRECT 10 x 10 1 Variable See Fan Performance Table 1 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 24x25 - 1 in. 3 Round Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I 20 20 20 20 3 — 45 3 — 56 Redundant - Two Stage 4 — 45 4 — 56 Redundant - Two Stage 5 — 45 5 — 56 Redundant - Two Stage 6 — 45 6 — 56 Redundant - Two Stage Hot Surface Igniter Multiport Inshot 3 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 4 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 5 115/1/60 13.5 20 1/2 HxWxD 41-3/4 x 23 x 30-1/2 Hot Surface Igniter Multiport Inshot 6 115/1/60 15.2 20 1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 158 / 146 168 / 156 197 / 185 206 / 193 1 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No. 12-1272-03 General Data ADH2 PRODUCT SPECIFICATIONS1 PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) 1 ADH2B060A9V3VA Downflow / Horizontal ADH2B080A9V3VA Downflow / Horizontal ADH2C100A9V4VA Downflow / Horizontal ADH2D120A9V5VA Downflow / Horizontal 39,000 37,000 60,000 57,000 95 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 14x20 - 1 in. 2 Round 52,000 49,400 80,000 76,000 95 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 14x20 - 1 in. 2 Round 65,000 61,750 100,000 95,000 95 35 - 65 DIRECT 10 x 10 1 Variable See Fan Performance Table 3/4 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 16x20 - 1 in. 3 Round 78,000 74,000 120,000 114,000 95 40 - 70 DIRECT 10 x 10 1 Variable See Fan Performance Table 1 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 16x20 - 1 in. 3 Round Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I 20 20 20 20 3 — 45 3 — 56 Redundant - Two Stage 4 — 45 4 — 56 Redundant - Two Stage 5 — 45 5 — 56 Redundant - Two Stage 6 — 45 6 — 56 Redundant - Two Stage Hot Surface Igniter Multiport Inshot 3 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 4 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 5 115/1/60 13.5 20 1/2 HxWxD 41-3/4 x 23 x 30-1/2 Hot Surface Igniter Multiport Inshot 6 115/1/60 15.2 20 1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 160/ 146 168 / 158 185 / 175 206 / 196 1 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub. No. 12-1272-03 7 Upflow Performance Data *UH2B060 FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 37,700 2nd Stage Capacity = 58,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 600 600 600 600 57 57 57 57 85 110 155 190 0.9 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 700 49 90 700 49 130 700 49 175 700 49 210 - NORMAL ** ON OFF CFM TEMP. RISE WATTS 775 44 105 775 44 155 775 44 195 775 44 240 - HIGH OFF OFF CFM TEMP. RISE WATTS 870 39 135 870 39 185 870 39 235 870 39 290 - LOW ON ON CFM TEMP. RISE WATTS 860 61 140 920 57 200 920 57 245 920 57 300 670 79 245 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1000 53 190 1000 53 255 1000 53 305 1000 53 340 700 75 255 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1125 47 250 1125 47 315 1125 47 370 1025 51 355 775 68 285 HIGH OFF OFF CFM TEMP. RISE WATTS 1250 42 340 1250 42 405 1250 42 445 1100 48 390 1000 53 355 - NOTES: *UH2B060 FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING LOW (350 CFM/TON) 1.5 2.0 2.5 3 DIP SWITCH SETTING SW 1 ON SW 2 ON SW 3 OFF EXTERNAL STATIC PRESSURE SW 4 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 575 65 575 90 575 125 550 155 - 70 110 140 175 NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 700 85 700 125 160 200 700 100 700 130 700 170 700 210 - - LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 800 115 800 155 800 200 800 250 - 900 140 900 195 900 240 900 290 - HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 875 130 875 180 875 230 875 270 - 1000 175 1000 235 1000 285 1000 335 900 310 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1125 235 1125 295 1125 345 1100 370 925 318 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1050 195 1050 260 1050 305 1050 350 920 315 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1200 275 1200 330 1200 385 1100 385 940 330 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1325 360 1325 425 1300 460 1175 425 1000 365 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. & HUMID CLIMATE setting; etting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 8 Pub. No. 12-1272-03 Upflow Performance Data *UH2B080FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 49,500 2nd Stage Capacity = 76,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 800 56 105 800 56 140 800 56 180 800 56 220 800 56 265 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 860 52 115 880 51 165 890 50 215 920 48 265 910 49 320 NORMAL ** ON OFF CFM TEMP. RISE WATTS 960 46 150 990 45 200 1000 44 230 1020 44 310 1010 44 350 HIGH OFF OFF CFM TEMP. RISE WATTS 1080 41 195 1110 40 255 1120 40 315 1120 40 365 1080 41 390 LOW ON ON CFM TEMP. RISE WATTS 1100 62 205 1100 62 260 1120 61 320 1120 61 370 1090 63 400 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1210 57 265 1240 55 340 1260 54 410 1260 54 470 1130 61 430 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1360 50 365 1390 49 445 1400 49 500 1360 50 535 1210 57 475 HIGH OFF OFF CFM TEMP. RISE WATTS 1360 50 355 1390 49 450 1400 49 520 1350 51 535 1180 58 465 S: *UH2B080 FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.0 2.5 3.0 3.5 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 0.1 0.3 0.5 0.7 0.9 750 84 750 122 750 154 720 185 710 221 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 840 109 840 146 840 181 840 226 820 264 HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 940 136 940 177 940 215 940 274 940 318 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 850 113 850 150 870 200 890 250 890 295 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 960 150 990 200 1000 230 1020 305 1010 350 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1080 195 1110 255 1120 315 1120 365 1080 390 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1020 175 1020 225 1040 280 1050 330 1050 375 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1170 240 1180 300 1200 365 1200 415 1130 420 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1290 310 1320 410 1350 470 1340 520 1150 440 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1170 250 1190 315 1210 370 1210 435 1100 405 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1360 365 1390 445 1400 500 1360 535 1210 475 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1360 355 1390 450 1400 520 1350 535 1180 460 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. & HUMID CLIMATE setting; TE setting. Pub. No. 12-1272-03 9 Upflow Performance Data *UH2C100 FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 61,750 2nd Stage Capacity = 95,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 873 893 900 899 64 63 62 62 100 145 195 240 0.9 902 62 290 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 971 58 115 997 56 170 1006 56 220 1022 55 280 1029 54 335 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1136 49 160 1146 49 230 1165 48 295 1180 47 365 1184 47 425 HIGH OFF OFF CFM TEMP. RISE WATTS 1258 44 225 1298 43 300 1319 42 390 1328 42 450 1286 44 490 LOW ON ON CFM TEMP. RISE WATTS 1260 68 213 1304 66 305 1329 65 380 1334 65 460 1317 65 510 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1464 59 315 1471 59 405 1478 58 485 1478 58 560 1350 64 540 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1631 53 450 1678 51 570 1690 51 670 1579 55 645 1419 61 585 HIGH OFF OFF CFM TEMP. RISE WATTS 1846 47 640 1867 46 760 1794 48 770 1644 52 700 1498 57 650 S: *UH2C100 FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4.0 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 808 75 824 125 840 170 835 210 830 250 OFF OFF CFM WATTS 938 100 963 160 959 205 964 255 975 310 ON ON OFF CFM WATTS 1058 150 1100 200 1121 265 1136 330 1142 395 OFF ON OFF ON CFM WATTS 1004 120 1010 175 1027 230 1044 285 1050 345 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1141 170 1190 245 1214 310 1229 380 1234 450 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1336 250 1375 330 1387 410 1388 480 1384 545 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1153 180 1206 250 1230 320 1239 395 1244 460 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1390 285 1418 465 1439 445 1441 515 1373 540 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1575 400 1606 495 1632 590 1596 645 1445 590 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1388 290 1423 360 1444 440 1444 515 1390 540 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1610 415 1641 515 1666 635 1607 650 1449 595 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1847 630 1863 735 1816 780 1687 720 1532 665 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 ately 50% of selected cooling value. & HUMID CLIMATE setting; etting; 10 Pub. No. 12-1272-03 Upflow Performance Data *UH2D120 FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 74,500 2nd Stage Capacity = 114,700 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 1090 1120 1080 1070 62 60 63 63 165 225 270 310 0.9 1010 67 380 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1210 56 220 1200 56 280 1200 56 330 1180 57 395 1160 58 455 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1340 50 295 1360 50 350 1370 49 425 1380 49 495 1330 51 535 HIGH OFF OFF CFM TEMP. RISE WATTS 1430 47 390 1570 43 490 1580 43 565 1570 43 625 1390 49 565 LOW ON ON CFM TEMP. RISE WATTS 1660 63 485 1690 62 590 1680 62 640 1640 64 675 1460 72 600 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1870 56 675 1870 56 745 1810 58 770 1680 62 715 1490 70 625 NORMAL ** ON OFF CFM TEMP. RISE WATTS 2060 51 880 1990 53 890 1850 57 810 1710 61 750 1530 68 665 HIGH OFF OFF CFM TEMP. RISE WATTS 2200 48 1030 2090 50 965 1940 54 895 1790 58 830 1640 64 750 S: *UH2D120 FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4.0 5 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 1210 220 1210 270 1220 325 1230 400 1230 445 OFF OFF CFM WATTS 1400 305 1440 390 1450 465 1450 510 1410 560 ON ON OFF CFM WATTS 1590 425 1600 520 1610 600 1600 645 1380 575 ON OFF OFF ON CFM WATTS 1390 305 1400 375 1430 445 1440 515 1420 565 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1620 420 1650 530 1670 595 1640 660 1480 600 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1840 600 1830 690 1820 765 1670 700 1490 620 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1800 570 1780 630 1780 705 1700 695 1530 615 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 2050 845 2010 875 1860 805 1710 735 1530 655 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2160 995 2040 935 1920 875 1780 805 1620 730 LOW (350 CFM/TON) OFF ON OFF NORMAL (400 CFM/TON) OFF ON HIGH (450 CFM/TON) OFF LOW (350 CFM/TON) SW 4 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; etting; TE setting. Pub. No. 12-1272-03 11 Downflow Performance Data *DH2B060 FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 1st STAGE CAPACITY = 37,000 2nd STAGE CAPACITY = 57,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 600 600 600 600 56 56 56 56 55 85 120 150 0.9 600 56 185 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 675 50 65 675 50 105 675 50 140 675 50 175 675 50 205 NORMAL ** ON OFF CFM TEMP. RISE WATTS 750 45 85 750 45 125 750 45 160 750 45 210 750 45 260 HIGH OFF OFF CFM TEMP. RISE WATTS 850 40 115 850 40 155 850 40 205 850 40 260 850 40 320 LOW ON ON CFM TEMP. RISE WATTS 900 58 125 900 58 165 900 58 220 900 58 270 900 58 315 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1000 52 170 1050 50 230 1050 50 295 1050 50 335 1050 50 370 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1100 47 215 1150 45 285 1150 45 340 1150 45 395 1100 47 440 HIGH OFF OFF CFM TEMP. RISE WATTS 1300 40 330 1325 39 385 1325 39 455 1250 42 465 1200 43 470 NOTES: *DH2B060 FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 1.5 2.0 2.5 3 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 0.1 0.3 0.5 0.7 0.9 525 45 525 70 525 100 525 135 525 160 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 600 55 600 85 600 120 600 150 600 185 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 675 65 675 105 625 140 675 175 675 205 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 700 70 700 115 700 145 700 185 700 220 NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 800 100 800 135 800 175 800 225 800 280 HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 900 125 900 165 900 220 900 270 900 330 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 875 115 875 160 875 210 875 260 875 310 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1000 150 1000 207 1000 265 1000 320 1000 380 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1125 215 1125 285 1125 340 1125 395 1125 440 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1050 175 1050 240 1050 305 1050 345 1050 380 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1200 240 1200 315 1200 385 1200 440 1100 410 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1350 330 1350 410 1350 500 1275 485 1170 450 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. & HUMID CLIMATE setting; TE setting. 12 Pub. No. 12-1272-03 Downflow Performance Data *DH2B080 FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE 1st STAGE CAPACITY = 49,400 2nd STAGE CAPACITY = 76,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 DIP SWITCH SETTING SW 7 SW 8 0.9 LOW ON ON CFM TEMP. RISE WATTS 800 56 130 800 56 170 800 56 210 790 56 245 - MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 900 49 162 900 49 210 900 49 260 900 49 295 - NORMAL ** ON OFF CFM TEMP. RISE WATTS 1000 44 205 1000 44 265 1000 44 310 1000 44 345 800 56 295 HIGH OFF OFF CFM TEMP. RISE WATTS 1170 38 305 1170 38 350 1170 38 400 1020 44 360 830 54 310 LOW ON ON CFM TEMP. RISE WATTS 1150 60 285 1150 60 345 1150 60 385 1020 67*** 360 830 83*** 305 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1275 54 380 1275 54 445 1200 57 425 1040 66*** 380 900 76*** 350 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1430 48 515 1340 51 490 1220 56 455 1090 63 410 930 74*** 380 HIGH OFF OFF CFM TEMP. RISE WATTS 1430 48 515 1340 51 490 1220 56 455 1090 63 410 930 74*** 380 NOTES: * - First letter may be "A" or "T" *** Above MAX Temperature change value *DH2B080 - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.0 2.5 3.0 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 700 95 700 105 700 115 680 200 670 235 OFF OFF CFM WATTS 800 130 800 160 800 205 790 245 740 265 ON ON OFF CFM WATTS 900 160 900 215 900 255 900 300 750 270 OFF ON OFF ON CFM WATTS 875 145 875 185 875 240 875 280 760 270 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1000 205 1000 265 1000 310 1000 340 800 295 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1150 295 1150 340 1150 385 1020 350 800 300 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1050 235 1050 295 1050 340 1010 350 800 290 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1200 335 1200 385 1200 410 1040 365 840 310 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1350 455 1350 480 1210 435 1070 390 900 345 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 12-1272-03 13 Downflow Performance Data *DH2C100 - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE 1st STAGE CAPACITY = 61,750 2nd STAGE CAPACITY = 95,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 DIP SWITCH SETTING SW 7 SW 8 0.9 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1020 55 145 1047 53 190 1053 53 250 1042 54 295 1029 54 350 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1156 48 185 1166 48 240 1172 48 300 1177 48 350 1178 48 420 HIGH OFF OFF CFM TEMP. RISE WATTS 1275 44 225 1305 43 290 1328 42 365 1328 42 445 1328 42 510 LOW ON ON CFM TEMP. RISE WATTS 1298 66 235 1320 65 305 1335 65 380 1343 64 445 1343 64 520 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1439 60 310 1459 59 390 1482 58 470 1483 58 550 1470 59 610 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1639 53 430 1650 52 525 1650 52 600 1644 52 680 1496 58 640 HIGH OFF OFF CFM TEMP. RISE WATTS 1790 18 570 1818 47 670 1813 47 770 1708 50 750 1535 56 675 923 61 110 955 59 165 960 58 210 958 58 265 947 59 310 ** Factory setting *** Above MAX temperature change *DH2C100 - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 AIRFLOW SETTING LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) 3.5 4.0 NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF 0.1 0.3 0.5 0.7 0.9 CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS 870 100 989 120 1124 175 1053 145 1186 195 1336 255 885 140 1018 180 1139 225 1075 200 1205 255 1366 340 887 185 1016 230 1130 275 1070 245 1220 310 1383 405 881 230 1012 285 1135 335 1070 295 1220 370 1385 470 876 270 999 325 1135 390 1049 350 1216 440 1381 545 CFM WATTS 1216 190 1225 255 1235 320 1240 385 1243 445 CFM WATTS CFM WATTS CFM WATTS CFM WATTS 1394 270 1579 395 1377 270 1599 425 1422 360 1604 475 1412 355 1624 510 1436 430 1610 555 1426 430 1636 585 1437 505 1599 645 1433 510 1618 670 1430 580 1517 640 1428 575 1512 635 CFM WATTS 1801 580 1818 690 1815 775 1694 735 1525 660 mately 50% of selected cooling value. & HUMID CLIMATE setting; TE setting. 14 Pub. No. 12-1272-03 Downflow Performance Data *DH2D120 - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 8 SW 7 1st STAGE CAPACITY = 74,000 2nd STAGE CAPACITY = 114,000 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 1025 1025 1000 1000 65 65 67 67 150 200 240 290 0.9 1000 67 340 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1200 56 230 1200 56 270 1200 56 330 1200 56 390 1200 56 450 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1350 49 280 1350 49 340 1350 49 490 1350 49 470 1350 49 530 HIGH OFF OFF CFM TEMP. RISE WATTS 1550 43 400 1550 43 490 1550 43 560 1550 43 620 1450 46 600 LOW ON ON CFM TEMP. RISE WATTS 1550 66 380 1550 66 470 1550 66 540 1550 66 610 1450 71*** 690 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1850 56 660 1850 56 750 1850 56 780 1700 60 720 1500 69 640 NORMAL ** ON OFF CFM TEMP. RISE WATTS 2050 50 860 2000 51 880 1850 56 810 1700 60 750 1550 66 670 HIGH OFF OFF CFM TEMP. RISE WATTS 2105 49 1000 2050 50 940 1900 54 880 1775 58 820 1625 63 750 S: *DH2D120 - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4.0 5 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 0.1 0.3 0.5 0.7 0.9 1225 240 1225 280 1225 340 1225 400 1225 450 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1400 310 1400 390 1400 470 1400 520 1400 570 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1600 450 1600 520 1600 590 1600 640 1450 600 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1400 300 1400 380 1400 450 1400 520 1400 570 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1600 460 1600 530 1600 610 1600 670 1450 600 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1800 610 1800 700 1800 760 1650 690 1500 630 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1750 580 1750 640 1750 720 1650 680 1450 610 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 2000 830 2000 860 1850 800 1700 740 1550 660 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2100 970 2000 910 1900 850 1650 780 1600 710 NOTES: * - First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 12-1272-03 15 Maximum Vent Length Table VENT LENGTH TABLE WITH BAYHALT KIT (HIGH ALTITUDE KIT) MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET ALTITUDE FOR VENT AND INLET AIR (SEE NOTES) 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE 5,000 - 12,000 Feet Natural Gas - All models Liquid Propane Gas - All models except *UH3, *DH3 *UY060R, *UH2B060A9V3V *UX060R, *UX2B060A9362 *UX2B060AFV3V *DY060R, *DH2B060A9V3V *DX060R, *DX2B060A9362 *UY080R, *UH2B080A9V3V *UH3B060ACV3V *DH3B060ACV3V 200 200 200 *UX080R, *UX2B080A9422 *UX2B080AFV3V *DY080R, *DH2B080A9V3V *DX080R, *DX2B080A9422 *UH3B080ACV3V *DH3B080ACV3V 50 120 200 Not Allowed 60 200 Not Allowed Not Allowed 200 *UY100R, *UH2C100A9V4V *UX100R, *UX2C100A9482 *UX2C100AFV4V *DY100R, *DH2C100A9V4V *DX100R, *DX2C100A9482 *UH3C100ACV4V *DH3C100ACV4V *UY120R, *UH2D120A9V5V *UX120R, *UX2D120A9602 *UX2D120AFV5V *DY120R, *DH2D120A9V5V *DX120R, *DX2D120A9602 *UH3D120ACV5V *DH3D120ACV5V Liquid Propane Gas - *UH3, *DH3 models ONLY *UH/DH3B060ACV3V *UH/DH3B080ACV3V *UH/DH3C100ACV4V Not Allowed Not Allowed 150 *UH/DH3D120ACV5V Not Allowed Not Allowed 100 NOTES: *First letter may be "A", "C" or "T" 1. Minimum vent length for all models: 3' horizontal and vertical. 2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET, (Except adapters at the top of the furnace). 3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or inlet air pipes). o 4. One SHORT radius 90 elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe. One 90o elbow is equivalent to 7-1/2' of 2-1/2" pipe or 5' of 2' pipe. Two 45o elbows equal one 90o elbow. 5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENT termination kit is used, the equivalent length is 0 feet. 6. Pipe adapters are field supplied (except 100,120,UX1C06A960 & all downflow models). 16 Pub. No. 12-1272-03 Electrical Data *UH2 SCHEMATIC DIAGRAM Pub. No. 12-1272-03 17 Electrical Data *DH2 Schematic Diagram 18 Pub. No. 12-1272-03 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY Pub. No. 12-1272-03 19 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) 20 Pub. No. 12-1272-03 (ALL DIMENSIONS ARE IN INCHES) *UH2 UPFLOW / HORIZONTAL OUTLINE DRAWING Dimensions Pub. No. 12-1272-03 21 22 Pub. No. 12-1272-03 (ALL DIMENSIONS ARE IN INCHES) *DH2 DOWNFLOW / HORIZONTAL OUTLINE DRAWING Notes Pub. No. 12-1272-03 23 6200 Troup Highway Tyler, TX 75707 www.trane.com American Standard has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. ">
Download
Advertisement
Key features
Variable Speed Blower Motor
Silicon Nitride Igniter
Two-Stage Gas Valve
Direct/Non-Direct Vent Option
Convertible to Horizontal
Stainless Steel Secondary Heat Exchanger
Frequently asked questions
The furnace is certified for both natural and L.P. gas. All models can be converted to L.P. gas without changing burners.
The furnace has an Integrated System Control that monitors for flame presence and a dual solenoid combination gas valve and regulator for additional safety.
The Integrated System Control contains connection points for E.A.C./Humidifier.
It utilizes an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, and a stainless steel secondary heat exchanger reclaims heat from flue gases.