TSX P57 processors: diagnostics Changing the RAM memory backup battery on TSX P57 At a Glance This battery, which is in the TSX PSY … power supply module (See Supply modules: description, p. 292), ensures that the internal RAM memory of the processor and the real-time clock are saved in case of a voltage power outage. It is delivered in the same packaging as the power supply module and must be installed by the user. Installing the battery Carry out the following steps: Step Action 1 Open the access flap on the front of the power supply module. 2 Place the battery in its slot, taking care to respect polarities as marked on the module. 3 Close the access flap. Illustration 171 TSX P57 processors: diagnostics Changing the battery The battery can be changed every year as a preventative measure or when the BAT LED is lit. To do this, use the same procedure as for installation, and carry out the following steps: Step Action 1 Open the access flap for the battery. 2 Remove the defective battery from its slot. 3 Put the new battery into place. 4 Close and lock the access flap. Illustration If there is a power outage while the battery is being changed, the processor ensures the RAM memory is saved, as it has its own offline independent save function. Note: so as not to forget to change the battery, you are advised to note the date of the next change in the space provided on the inside of the flap. 172 TSX P57 processors: diagnostics How often must the battery be changed? Period of battery backup The length of time during which the battery ensures backup of the processor’s internal RAM memory and the real-time clock depends on two factors: l the percentage of time for which the PLC is switched off and therefore the battery is being used, l the ambient temperature when the PLC is switched off. Summary table: ≤ 30°C 40°C 50°C 60°C PLC off for 12 hours 5 years per day 3 years 2 years 1 year PLC off for 1 hour per day 5 years 4.5 years 4 years Ambient temperature when inoperative Backup time 5 years Independent saving by the processor The processors have their own offline independent save function to save the processor’s internal RAM memory and the real-time clock, which allows the removal of: l the battery, the power supply or the TSX P57 processor. The backup time depends on the ambient temperature. Assuming that the processor was switched on previously, the guaranteed time varies in the following way: Ambient temperature when switching off 20°C 30°C 40°C 50°C Backup time 2h 45mn 20mn 8mn 173 TSX PSY … supply modules: diagnostics Back-up battery on TSX PSY ... power supply modules At a Glance Each power supply module has a slot for the installation of a battery which supplies the internal RAM memory of the processors in order to save the data when the PLC is switched off. This battery is delivered in the same packaging as the power supply module. When inserting it, you must respect the polarities. Note: If a Atrium processor which can be integrated into a PC is being used, the back-up battery is built into the processor and its characteristics are the same as those described below. Data on the backup battery Battery characteristics: thyonile lithium chloride battery, 3.6V/0.8 Ah, 1/2AA size. Spare part product reference: TSX PLP 01. Period for which data is stored: the data storage time depends on two factors: l the percentage of time for which the PLC is switched off and as a result the battery is being used, l the ambient temperature when the PLC is switched off. Table of the ambient temperatures when switched off: Ambient temperature when inoperative ≤ 30°C 40°C 50°C 60°C Backup time PLC off for 12 hours per day 5 years 3 years 2 years 1 year PLC off for 1 hour per day 5 years 5 years 4.5 years 4 years Monitoring the battery status: when the power is on, it monitors the status of the battery. If there are problems, the user is informed visually by the BAT (red) LED which lights up. If this happens, the battery must be changed immediately. The %S68 system bit gives the status of the backup battery (0 = battery OK). Changing the battery: the battery can be changed when the power supply module is on, or immediately after switching it off. In the latter case, the time for intervention is limited. The backup time depends on the ambient temperature. Assuming that the processor was switched on previously, the guaranteed time varies in the following way. Ambient temperature when switching off 20°C 30°C 40°C 50°C Backup time 2h 45mn 20mn 8mn 315 ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات