ASCON TECNOLOGIC KM1 Temperature Controller Quick Guide
PDF
Dokument
Reklama
Reklama
TEMPERATURE CONTROLLER 1/16 DIN - 48 x 48 KM1 model ube Manual mode www.ascontecnologic.com Output LEDs Once connected to the web-site, search: KM1 then click on KM1. In the lower part of the product page (in any language) is present the download area with links to the documents available for the controller (in the available languages). Operator Mode Access to: - Operator Commands (Timer, Setpoint selection ...) - Parameters - Configuration Warning! MODEL CODE Overall dimensions (L x H x D): 48 x 48 x 63 mm (1.89 x 1.89 x 2.48 in.) Panel Cut-out (L x H): 45+0.6 x 45+0.6 mm (1.78+0.023 x 1.78+0.023 in.) MOUNTING Editing Mode 3 2 Confirm and go to Next parameter Increase the displayed Access to: value or select the - Operator additional information next element of the (Output value, running time ...) parameters list Decrease the displayed Access to: value or select the - Set Point previous element Exit from Operator Programmable key: commands/Parameter Start the programmed function setting/Configuration (Autotune, Auto/Man, Timer ...) - Whenever a failure or a malfunction of the device may cause dangerous situations for persons, things or animals, please remember that the plant must be equipped with additional devices which will guarantee safety. - We warrant that the products will be free from defects in material and workmanship for 18 months from the date of delivery. Products and components that are subject to wear due to conditions of use, service life and misuse are not covered by this warranty. viale Indipendenza 56, 27029 - Vigevano (PV) - ITALY Tel.: +39 0381 698 71, Fax: +39 0381 698 730 internet site: www.ascontecnologic.com E-mail: [email protected] Process Value (in eng. units) Autotune in progress (flashing) Set Point (auto mode) Output Value (manual mode) Param. value or State/Function (Editing mode) Unit (°C/°F) Alarm active KM1 is a panel mounting, Class II instrument. It has been designed with compliance to the European Directives. All information about the controller use can be found in the Engineering Manual: ISTR-MKM_-ENG0x (“x” is the revision). The Declaration of Conformity and the manual of the controller can be downloaded (free of charge) from the web-site: Quick Guide • ISTR-FKM1ENG03 DIMENSIONS DISPLAY AND KEYS DECLARATION OF CONFORMITY AND MANUAL RETRIEVAL 1 2 1 ELECTRICAL CONNECTIONS TERMINALS The Hardware resources are identified by the following Model Code. Model: KM 1 A B C D E F G H I - 0 0 0 0 DI1 OP1 KM Line 1 Optional functions A None - Timer T Power Supply B 100... 240Vac (-15... +10%) H 24Vac (-25... +12%) or 24Vdc (-15... +25%) L Input C TC, PT100, PT1000, mA, mV, V + Digital Input 1 C TC, NTC, PTC, mA, mV, V + Digital Input 1 E Output OP1 D Relay (1 SPST NO, 4 A/250 Vac) R VDC for SSR (12 Vdc/20 mA) O Output OP2 E None - Relay (1 SPST NO, 2 A/250 Vac) R VDC for SSR VDC (12 Vdc/20 mA) O None - Relay (1 SPST NO, 2 A/250 Vac) R VDC for SSR (12 Vdc/20 mA) O Output OP4 G Digital I/O (see the Electrical Connections paragraph for details) D Serial Communications H TTL - RS485 Modbus S Terminal Type I Standard (screw type non removable terminal blocks) - With plug-in screw type terminal blocks E With plug-in clamp type terminal blocks M With plug-in terminal blocks (fixed part only) N q RS485 F Output OP3 Pin connector 1.4 mm max. (0.055 in.) OP2 L DI2 (note) OP4 OP3 (note) Analogue input PV Line 100... 240 Vac/ 20... 30 Vdc/ Neutral 18... 28 Vac 12 VDC (note) 4... 20 mA 2 wire transmitter mV, V Thermocouple mA Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 16; - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 16; - 12 Vdc (20 mA) transmitter power supply connecting the 2 wire transmitter between terminals 4 and 1; for 3 wire transmitter connect terminal 4 to transmitter power supply input and terminal 1 and 2 to transmitter signal output. 12 VDC (note) PV Model Code example: KM1-HCRRRD-Controller KM1, no timer, 100... 240 Vac, TC/PT100/PT1000/mV/V + Digital Input 1, 3 Relay Outputs, Output 4, TTL, non removable screw type terminals. Stripped wire L: 5.5 mm (0.21 in.) 4... 20 mA 3 wire transmitter Pt1000/NTC/PTC Pt100 CONFIGURATION CODE The KM1 can be easily configured by the “Code Configuration” method for the most common requirements, just entering two 4-digit codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. For complete controller configuration see the Engineering Manual. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: HOW TO SET THE CONFIGURATION CODE L M N L MN O User c%d1 AT Press for 3 seconds to access the configuration mode PV AT Press and to enter the configuration Password 4 (default 300) PV L M TC J -50... +1000°C 0 0 OP1 OP2 OP3 OP4 N O H AL1 AL2 AL3 0 TC K -50... +1370°C 0 1 0 NU AL1 AL2 H 0 TC S -50... 1760°C 0 2 1 C AL1 AL2 AL3 0 2 TC R -50... +1760°C 0 3 TC T -70... +400°C 0 4 NU AL1 AL2 C 0 3 H C AL2 AL3 0 4 Infrared J -50... +785°C 0 5 H AL1 AL2 C 0 5 Infrared K -50... +785°C 0 6 PT 100/PTC KTY81-121 -200... +850°C/-55... +150°C 0 7 C H AL2 AL3 0 6 NU H AL2 C 0 PT 1000/NTC 103-AT2 -200... +850°C/-50... +110°C 0 7 8 C AL1 AL2 H 0 8 Linear 0... 60 mV 0 9 NU C AL2 H 0 9 Linear 12... 60 mV 1 0 H AL1 AL2 AL3 1 0 Linear 0... 20 mA (this selection forces Out 4 = TX) 1 1 NU AL1 AL2 H 1 1 Linear 4... 20 mA (this selection forces Out 4 = TX) 1 2 C AL1 AL2 AL3 1 2 Linear 0... 5 V 1 3 NU AL1 AL2 C 1 3 Linear 1... 5 V 1 4 H C AL2 AL3 1 4 Linear 0... 10 V 1 5 H AL1 AL2 C 1 5 C H AL2 AL3 1 6 NU H AL2 C 1 7 Press and to enter c%d1 (Input Type and Control Mode) PV PID heating = H PID cooling = C 6 7 TC K -58... +2498°F 1 8 C AL1 AL2 H 1 8 TC S -58... 3200°F 1 9 NU C AL2 H 1 9 TC R -58... +3200°F 2 0 TC T -94... +752°F 2 1 Infrared J -58... +1445°F 2 2 Infrared K -58... +1445°F 2 3 PT 100/PTC KTY81-121 -328... +1562°F/-67... +302°F 2 4 PT 1000/NTC 103-AT2 -328... +1562°F/-58... +230°F 2 5 P Q R R Q P Not used 0 0 Sensor break 1 1 Absolute Absolute High/Low Deviation Band ON ON Absolute High-Low Alarm PV Time ON Absolute External Absolute Internal Note: As default, when the alarms are active, only AL1 threshold is available at “Operator Command” level to perform non critical tasks. To protect the AL2 and AL3 thresholds against undesired changes, they are available only at “Parameters list” level (password: 20). For different configurations, see the Engineering Manual. ON ON ON Deviation Alarm PV Time P Q R S Alarm 1 AT PID double action (H/C) Time ON Absolute High Absolute Low c%d2 S Alarm 2 Note: To leave the Configuration session without saving the settings made, press the button ON/OFF with neutral zone (H/C) 1 Alarm 3 Press to store the Configuration code ON/OFF cooling = C 1 User c%d2 PV ON/OFF heating = H -58... +1832°F AT Press and to enter c%d2 (Alarms and Service Functions) Control mode TC J Linear 2... 10 V AT Absolute Alarm PV Input Type and Range PV ALARM TYPES (Cod2 digits: P, Q, R) c%d1 O Service functions activation S None 0 Wattmeter (instantaneous power expressed in kW) (note 1) 1 0 Wattmeter (Power consuption expressed in kWh/h) (note 2) 2 1 Absolute worked time (expressed in days) (note 3) 3 Absolute worked time (expressed in hours) (note 3) 4 High 2 2 2 Low 3 3 3 External High/Low 4 4 4 Internal High/Low 5 5 5 Deviation high 6 6 6 Deviation low 7 7 7 External band 8 8 8 Internal band 9 9 9 ON Deviation High Notes: 1. Wattmeter Instantaneous power is continuously computed as multiplication of the Load Voltage, Load Current parameter values and the controller output instantaneous value. 2.Wattmeter power consumption is the estimated hourly energy consumption (using Load Voltage and Load Current parameter values), computed on the previous 15 minutes period. The readout is updated every 15 minutes. 3.Worked Time counter is continuously increased when the controller is turned ON. ON Deviation Low ON Band Alarm PV Band Internal Band External ON ON ON ON Time ON Parameters List (PASS: 20) (in gray the parameters related to optional features) PARAMETERS SETTING Group Param. Description Range value or selection list elements Default tr.St Timer status Password 2 (default: 20) Commands a.sp Access to parameters Press the key for 3 seconds Password 4 (default: 300) To Code configuration mode (cod1, cod2 tables on the front page) Control To exit the parameter setting procedure press the key (for 3 s) or wait until the timeout expiration (about 30 seconds). Set Point CONTROLLER OPERATION Additional Information 248.0 H035 248.0 Heating 248.0 Timer remaining time Cooling C045 Output Value % (e.g. heating = 35%, cooling = 45%) Depending on Cod2 digit S setting 248.0 U854 Power (kW) 248.0 or Energy (Wh) Worked time (days) d854 248.0 t04.8 h854 Worked time (hours) If active key for 3 seconds or wait for the 10s timeout To return to the Normal Mode, press the Set Point Selection tune Start Auto Tune Parameters setting Confirm and go to Next parameter Increase the displayed value or select the next element Decrease the displayed value or select the previous element oPEr Operative Mode Selection 20 ti Integral Time 0... 10000 s 200 td Derivative Time 0... 1000 s 50 0... 9999 (E.U.) 1 Cod1 Digit N = 0 0.1... 130 s 20.0 rcg Relative Cooling Gain 0.01... 99.99 1.00 tcc Cooling output cycle time 0.1... 130 s 20.0 Cod1 Digit N = 1 Cod1 Digit N = 1 Cod1 Digit O > 4 Cod1 Digit N = 1 Cod1 Digit O > 1 SP Set Point 1 -1999... +9999 (E.U.) SP2 Set Point 2 SP3 Set Point 3 SP4 Set Point 4 248.0 250.0 Operative Set Point Changed operative Set Point SPLL... 9999 (E.U.) nSP No. of Set Points 1... 4 AL1 Alarm 1 threshold AL1L... AL1H Alarm 2 threshold al2l Alarm 2 low threshold/Low limit al2H Alarm 2 high threshold/High limit HAL2 AL2 hysteresis Input EVOTUNE is a fast and fully automatic proceDot flashes dure that can be started in any while the condition, regardless the deviation Auto-tune from SP. is in progress The controller selects automatically the best tune method and computes the optimum PID parameters. Start 248.0 248.0. Auto-tune started Auto-tune in progress tunE Press the key for 3 s 248.0 Alarm 3 threshold tr.st run a.sp 1 Active Set Point selection Confirm/Next sp sp2 If more than 1 Set Point active (nsp > 1) 120.0 Confirm/Next AL1 Back to the first parameter To return to the Normal Mode, press the 250 If AL1 is active 9999 1... 9999 (E.U.) 1 -1999 -1999... +9999 (E.U.) 9999 1 Sst Soft Start Time 0.00... 8.00 (hh.mm) 0 ssc Low Scale readout -1999... 9999 -1999 fsc High Scale readout -1999... 9999 9999 dP Number of decimals 0... 3 (linear inputs); 0... 1 (other inputs) 0 FiL Measured value Digital filter OFF; 0.1... 20.0 s nonE = Timer not used i.d.A = Delayed ON at start command i.uP.d = Activation ON at Power ON i.d.d = At start command i.P.L = Asymmetrical oscillator, start in OFF i.L.P = Asymmetrical oscillator, start in ON 0 = hh.mm 1 = mm.ss 2 = sss.d 00.01... 995.9 0 = OFF Timer Type tr.u Timer Units none 1= mm.ss 1.00 diF.1 Digital Input 1 Function Digital Inputs diF.2 Digital Input 2 Function 0... 21 0 nonE, tunE, oplo, aac, asi, chsp, st.by, str.t 0 = Change 1 = Red 2 = Green 3 = Orange tunE usrb Key Function Display ade Display change color threshold (when di.Cl = 0) Confirm/Next Password Uolt Load Voltage cur Load Current 1.00 If digit R of Cod2 is > 1 For linear Input types only Timer management (Start, Stop, Reset) can be done using the tr.St command or the key (if programmed) or by the DI1/DI2 digital inputs (if programmed). ON 0 2 0 (OFF)... 9999 (e.u.) dis.t Display Power OFF time (mm.ss) oFF (display ON) 0.1... 99.59 Add Instrument Address Serial communibAud Baud rate cations If digit Q of Cod2 is > 1 AL3L... AL3H io4.F I/O 4 Function Wattmeter key for 3 seconds or wait for the 10s timeout -1999 -1999... +9999 (E.U.) I/O sp4 340.0 1 0 tr.F If digit P of Cod2 is > 1 AL2L... AL2H -100... 100% di.cl Colour of the Process Value display nsp > 3 225.0 1... 9999 (E.U.) 00.00... 995.9 ON = Transmitter Power Supply OUT4 = SSR out Di2C = Dig. In. from contact Di2U = 24 VDC Digital Input 0... 21 nsp > 2 sp3 9999 1... 9999 (E.U.) tr.t2 Time 2 st Increase 1 SP value Decrease change 248.0 Confirm/Next nsp > 1 run: Start If timer hold: Hold activated res: Reset ( tr.F ) Confirm/Next -1999 -1999... +9999 (E.U.) Soft Start Output value tr.t1 Time 1 Operator Command 1 stp Timer key could be assigned by the user to Note: The other functions using the Usrb parameter setting If nSP > 3 SPHL Set Point max. Value AL2 If nSP > 2 -1999... +9999 (E.U.) -1999... SPHL (E.U.) HAL1 AL1 hysteresis Soft Start If nSP > 1 SPLL Set Point min. Value HAL3 AL3 hysteresis Press the key (3 s) or wait for the 10s time out to store the new Set Point and return to Normal Mode Cod1 Digit N = 1 Heating output cycle time al3H Alarm 3 high threshold/High limit sp evoTUNE tc.H HSEt Hysteresis ON/OFF Control al3l Alarm 3 low threshold/Low limit Increase value Decrease value 0 = OFF 1... 9999 (Engineering Units = E.U.) AL3 sp 0 = SP 0 = oFF, 1 = start Proportional Band al1H Alarm 1 high threshold/High limit Set Point Change Note Option reg = Auto, oplo = Manual, stdy = Standby 0 = SP, 1 = SP2, 2 = SP3, 3 = SP4 Pb al1l Alarm 1 low threshold/Low limit Alarms User value See the DI1, DI2 functions table See the Key function table If Change, the colour is green if PV differs from SP less than Ade, red if higher than Ade and orange if is lower than Ade oFF 1... 254 1200, 2400, 9600 baud, 19.2, 38.4 kbaud 1 1... 999 (V) 230 9600 1... 9999 (A) PAS4 Configuration access Password 0... 999 300 PAS2 Parameters access Password 0... 999 20 Modbus RTU slave protocol If digit S of Cod2 is > 1 Note: To access all the instrument features, please see the “Complete configuration procedure” in the “Engineering Manual”. Complete Configuration and Parameter setting can be easily uploaded from the controller and downloaded to other controllers using the: Configuration Key and Communication Adapter model: A-01. FUNCTION SELECTION Timer Types (selected by tr.f) (option) i.d.a Delayed ON at Start command Start OUT i.p.l Asymmetrical oscillator with start in OFF Tr.t1 Tr.t2 off ON off PWR ON i.up.d Delayed ON at Power ON OUT i.d.d Tr.t1 Tr.t2 off ON ON PWR ON OUT Reset off ON Tr.t1 off ON Tr.t2 Tr.t1 off ON Start off OUT Reset Tr.t1 ON Tr.t2 off Tr.t1 ON Tr.t2 off Tr.t1 ON Tr.t2 off usrb Key Function Code displayed 0 1 2 3 4 5 6 7 8 9 10 11 Code displayed nonE tune oplo aac asi chsp st.by str.t Description 12 Tr.t1 OUT Reset Tr.t1 Tr.t2 i.L.p Asymmetrical oscillator with start in ON PWR ON At Start command Start Start Tr.t2 dif$ Digital Inputs DI1 and DI2 Functions off 18 19 20 21 Description Disabled (OFF) (default) Alarm Reset Alarm Acknowledge (ACK) Hold of the measured value Stand by mode Manual Mode Heat with “SP” and CooL with “SP2” Timer Run/Hold/Reset [on transition] Timer Run [on transition] Available only if Timer Reset [on transition] timer option and Timer Run/Hold tr.F is NOT set to Timer Run/Reset nonE Timer Run/Reset with lock at the end of the time count Sequential Set Point selection [on transition] SP/SP2 selection Binary coding for Set Point selection on DI1 and DI2 (00 = SP, 01 = SP2, 10 = SP3, 11 = SP4) Digital inputs in parallel to the UP and Down keys (DI1 = UP key, DI2 = DOWN key) Not used Starts auto tuning functions (default) Manual mode Alarm Reset Alarm Acknowledge Circular Set Point Selection (shows SP, SP2, SP3) Stand-by mode Starts/Stop/Reset timer ">
/
Preuzimanje
Samo prijateljski podsetnik. Dokument možete pogledati ovde. Ali što je najvažnije, naš AI ga je već pročitao. Može da objasni složene stvari jednostavnim rečima, odgovori na vaša pitanja na bilo kom jeziku i pomogne vam da brzo navigirate čak i najdužim ili najkomplikovanijim dokumentima.
Reklama