9200 Serial Communications Protocol and ION / Modbus Register Map This document explains the Modbus protocol on the 9200 meter. The 9200 meter performs Modbus RTU communications according to the Modicon Standard. Refer to www.modicon.com for Modbus/TCP standard and Modicon Modbus Serial Communications Protocol documentation. This document describes the Modbus communications protocol employed by the meter and how to pass information into and out of the meter in a Modbus network. It is assumed that the reader is familiar with the Modbus protocol and serial communications in general. In This Document Purpose of the Communications Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Modbus Implementation on the Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Modes of Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description of the Modbus Packet Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Exception Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Broadcast Packets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Packet Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Function 03: Read Holding Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Function 16: Preset Multiple Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Invalid Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Meter Modbus Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Metered Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Control Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Setup Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Appendix A: CRC-16 Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pseudocode For CRC-16 Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Appendix B: ION / Modbus Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Read-Write Configuration Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Read-Write Control Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 © 2005 Siemens Energy & Automation. All rights reserved. The information in this document is believed to be accurate at the time of publication, however, Siemens Energy & Automation assumes no responsibility for errors which may appear here and reserves the right to make changes without notice. ION is a registered trademark of Power Measurement Ltd. All other trademarks are property of their respective owners. Revision Date: Jan. 27, 2005 Purpose of the Communications Protocol 9200 Modbus Protocol Purpose of the Communications Protocol The 9200 meter Modbus communications protocol allows measured data and setup information to be efficiently transferred between a Modbus master station and a meter. This includes: Interrogation of all data measured by the meter Configuration and interrogation of the meter Interrogation and control of the meter’s digital outputs Clearing of accumulated demand and energy parameters Page 2 9200 Modbus Protocol Modbus Implementation on the Meter Modbus Implementation on the Meter Ground Rules The meter is capable of communicating via the RS-485 serial communication standard. The RS-485 medium allows for multiple devices on a multi-drop network. The points below follow the Modicon standard: All communications on the communications loop conforms to a master/slave scheme. In this scheme, information and data is transferred between a Modbus master device and up to 32 slave monitoring devices (more, if repeaters are used). The master initiates and controls all information transfer on the communications loop. A slave device never initiates a communications sequence. All communications activity on the loop occurs in the form of “packets.” A packet is a serial string of 8-bit bytes. The maximum number of bytes contained within one packet is 255. All packets transmitted by the master are requests. All packets transmitted by a slave device are responses. At most one slave can respond to a single request from a master. Modes of Transmission The Modbus protocol uses ASCII and RTU modes of transmission. The meter supports only the RTU mode of transmission, with 8 data bits, no parity, and one stop bit. Description of the Modbus Packet Structure Every Modbus packet consists of four fields: Slave Address Field Function Field Data Field Error Check Field (Checksum) Slave Address Field The slave address field of a Modbus packet is one byte in length and uniquely identifies the slave device involved in the transaction. Valid addresses range between 1 and 247. A slave device performs the command specified in the packet when it receives a request packet with the slave address field matching its own address. A response packet generated by the slave has the same value in the slave address field. Page 3 Description of the Modbus Packet Structure 9200 Modbus Protocol Function Field The function field of a Modbus request packet is one byte in length and tells the addressed slave which function to perform. Similarly, the function field of a response packet tells the master what function the addressed slave has just performed. “Table 1: Modbus Functions Supported by the Meters” lists the Modbus functions supported by the meter. Table 1: Modbus Functions Supported by the Meters Function Meaning Action 03 Read Holding registers Obtains the current value in one or more holding registers of the meter. 16 Preset Multiple registers Places specific values into a series of consecutive holding registers of the meter. The holding registers that can be written to the meter are shown in the register map. Data Field The data field of a Modbus request is of variable length, and depends upon the function. This field contains information required by the slave device to perform the command specified in a request packet or data being passed back by the slave device in a response packet. Data in this field are contained in 16-bit registers. Registers are transmitted in the order of high-order byte first, low-order byte second. This ordering of bytes is called “Big Endian” format. Example: A 16-bit register contains the value 12AB Hex. This register is transmitted: High order byte = 12 Hex Low order byte = AB Hex This register is transmitted in the order 12 AB. Error Check Field (Checksum) The checksum field lets the receiving device determine if a packet is corrupted with transmission errors. In Modbus RTU mode, a 16-bit Cyclic Redundancy Check (CRC-16) is used. The sending device calculates a 16-bit value, based on every byte in the packet, using the CRC-16 algorithm. The calculated value is inserted in the error check field. The receiving device performs the calculation, without the error check field, on the entire packet it receives. The resulting value is compared to the error check field. Transmission errors occur when the calculated checksum is not equal to the checksum stored in the incoming packet. The receiving device ignores a bad packet. The CRC-16 algorithm is detailed in appendix A of this document. Page 4 9200 Modbus Protocol Exception Responses Exception Responses If a Modbus master device sends an invalid command to a meter or attempts to read an invalid holding register, an exception response is generated. The exception response follows the standard packet format. The high order bit of the function code in an exception response is set to 1. The data field of an exception response contains the exception error code. “Table 2: Exception Codes Supported by the Meter” on page 5 describes the exception codes supported by the meter and the possible causes. Table 2: Exception Codes Supported by the Meter Code Name Meaning 01 Illegal Function An invalid command is contained in the function field of the request packet. The meter only supports Modbus functions 3 and 16. 02 Illegal Address The address referenced in the data field is an invalid address for the specified function. This could also indicate that the registers requested are not within the valid register range of the meter. 03 Illegal Value The value referenced in the data field is not allowed for the referenced register on the meter. Broadcast Packets The 9200 Modbus protocol supports broadcast request packets. The purpose of a broadcast request packet is to allow all slave devices to receive the same command from the master station. A broadcast request packet is the same as a normal request packet, except the slave address field is set to zero (0). All Modbus slave devices receive and execute a broadcast request command, but no device will respond. The Preset Multiple registers command (function 16) is the only command supporting broadcast packets. Page 5 Packet Communications 9200 Modbus Protocol Packet Communications This section illustrates the Modbus functions supported by the meter. Function 03: Read Holding Registers To read meter parameter values, a master station must send the slave device a Read Holding registers request packet. The Read Holding registers request packet specifies a start register and a number of registers to read. The start register is numbered from zero (40001 = zero, 40002 = one, etc.). The meter responds with a packet containing the values of the registers in the range defined in the request. Read Holding Registers Read Registers Request Packet (master station to meter) Read Registers Response Packet (meter to master station) Unit ID/Slave Address (1 byte) Unit ID/Slave Address (1 byte) 03 (Function code) (1byte) 03 (Function code) (1 byte) Start Register (sr) (2 bytes) Byte Count (2 x nr) (1 byte) # of Registers to Read (nr) (2 bytes) First Register in range (2 bytes) CRC Checksum Second Register in range (2 bytes) ... CRC Checksum (2 bytes) Example: A meter in 4-wire WYE volts mode is configured as a Modbus slave device with slave address 100. The master station requests to read realtime volts on all three phases (A, B, C). These three parameters are available in Modbus registers 40100, 40101 and 40102, with a user programmable scaling factor (default 10). In accordance with the Modbus protocol, register 40100 is numbered as 99 when transmitted. The request must read 3 registers starting at 99. Slave address: 100 = 64 (hex) Start register 99= 0063 (hex) Request Packet Page 6 Slave Function Start Register # of Registers (3) CRC Checksum 64* 03 00 00 FC 63 03 20 9200 Modbus Protocol Function 16: Preset Multiple Registers Response Packet Slave Function Byte Count Register 1 64 03 06 2E Register 2 CE 2E Register 3 E8 2F CRC Checksum 13 58 0D The master station retrieves the data from the response: Register 40100: 2ECE (hex) = 11982 (scaled: 1198.2) Register 40101: 2EE8 (hex) = 12008 (scaled: 1200.8) Register 40102: 2F13 (hex) = 12051 (scaled: 1205.1) * The values shown in illustrated packets are represented in hexadecimal format. Function 16: Preset Multiple Registers The Preset Multiple registers command packet allows a Modbus master to configure or control the meter. A Preset Multiple registers data-field request packet contains a definition of a range of registers to write to, and the values that write to those registers. The meter responds with a packet indicating that a write was performed to the range of registers specified in the request. The table below, shows the Preset Multiple registers request and response packet formats, and an example transaction. Preset Multiple Registers Preset Registers Request Packet (master station to meter) Preset Registers Response Packet (meter to master station) Unit ID/Slave Address (1 byte) Unit ID/Slave Address (1 byte) 16 (Function code) (1byte) 16 (Function code) (1 byte) Start Register (sr) (2 bytes) Start Register (sr) (2 bytes) # of Registers to Write (nr) (2 bytes) # of Registers Written (nr) (2 bytes) Byte Count (2 x nr) (1 byte) CRC Checksum (2 bytes) First Register in range (2 bytes) Second Register in range (2 bytes) ... CRC Checksum (2 bytes) Page 7 Invalid Registers 9200 Modbus Protocol Example: A meter is configured as a Modbus slave device with slave address 200. The master station requests to set the PT ratio to 1200:120. From the register map, the Power Meter PT Primary and Secondary setup registers are Modbus registers 44002 and 44003. Register 44002 is numbered 4001 when transmitted. The request must write two registers starting at 4001. Slave address: 200 = C8 (hex) Start register 4001 = 0FA1 (hex) Value 1: 1200 = 04B0 (hex) Value 2: 120 = 0078 (hex) Request Packet Slave Function Start Register # of Registers (4) Byte Count Register 1 Register 2 CRC Checksum C8* 10 0F 00 04 04 00 EE A1 02 B0 78 3F Response Packet Slave Function Start Register C8 10 0F * A1 # of Registers (4) CRC Checksum 00 01 02 E0 The values shown in illustrated packets are represented in hexadecimal format. Invalid Registers In the meter Modbus register map, there are reserved sections. For example, registers before 40500 are reserved. When a reserved register is read, the value returned is FFFF (hex). When a reserved register is written, the value supplied is not stored. The meter does not reject the request. Page 8 9200 Modbus Protocol Meter Modbus Registers Meter Modbus Registers The 9200 meter supports Modbus Holding registers (address range 4xxxx). There are three types of parameters: Metered Parameters External Control/Reset Parameters Setup Parameters Enumerated Setup Parameters Numeric Bounded Parameters Metered Parameters All the values measured by the meter are available through the Modbus protocol. The majority of these parameters have fixed scaling. However, the scaling of voltage, current and power values is configurable via a numeric setup register. There are three blocks. Factory registers such as serial number, firmware revision, etc. are located between addresses 40001 and 40099. Measured quantities such as voltage, current, power and energy are located between addresses 40100 and 40499. The register addresses for the first Feature Pack start at 40500; the register addresses for the second Feature Pack start at 40600. Consult the Feature Pack documentation for the contents of these registers. The 9200 supports 4 data formats: Unsigned 16-bit Integer Format Signed 16-bit Integer Format Unsigned 32-bit Integer Format Signed 32-bit Integer Format 16-bit Integer Format Unsigned and Signed 16-bit Integer Formats are the simplest formats. If the format is unsigned the value range for the output registers is 0 to 65535. If the format is signed, the value range is -32767 to +32767 (two’s-complement). 32-bit Integer Format To accommodate values that can reach beyond the 16-bit limitation, the 9200 provides 32-bit integer format. In Signed and Unsigned 32-bit Integer Formats, the 32-bit value is split into two consecutive 16-bit registers. The first register is the low-order word and the second register is the high-order word. To interpret the value, take the second register (high-order word) and multiply by 65536. Then add the first register (low-order word). The formula is: value = (second register x 65536) + first register Page 9 Control Parameters 9200 Modbus Protocol In Unsigned 32-bit Integer Format, both the high-order and low-order registers are unsigned 16-bit integers. Example: Value 12345678 is passed in unsigned 32-bit integer format: 12345678 = 00BC614E Hex First Register = 614E Hex (unsigned) = 24910 Second Register = 00BC Hex (unsigned) = 188 value = (188 x 65536) + 24910 = 12345678 In Signed 32-bit Integer Format, the high-order register is a signed 16-bit number, but the low-order register is unsigned. Example: Value -12345678 is passed in signed 32-bit integer format: -12345678 = FF439EB2 Hex First Register = 9EB2 Hex (unsigned) = 40626 Second Register = FF43 Hex (signed) = -189 value = (-189 x 65536) + 40626 = -12345678 Control Parameters There are two types of control parameters in the meter which can be accessed via Modbus. This section describes how the parameters appear to the Modbus protocol. The two control parameters types are: Digital Output Control registers Accumulation Reset registers Digital Output Control Registers 42004 and 42005 are available to remotely control the meter’s digital outputs. A non-zero value written to these registers places the corresponding digital output in an asserted state. Conversely, a logic zero written to one of these registers de-asserts the output. To use the Read-Write Control Map, it is recommended that your 9200 meter has firmware version 202 or later. For detailed information contact Technical Services. Reset Accumulation Registers 42001 to 42003 are available to remotely reset energy accumulation and maximum demand values. Writing any value to one of these registers causes the corresponding parameter to reset. If read, these registers will return an error. Page 10 9200 Modbus Protocol Setup Parameters Setup Parameters Meters can be configured remotely via Modbus communications. Registers 4400 to 44029 offer enumerated or numeric parameters. Enumerated Setup Enumerated registers are used where a list of options are available. For example, the Volts Mode register has five options: 4W-WYE, DELTA, SINGLE, DEMO, 3W-WYE and DELTA DIRECT. These options are represented by a numeric relationship; for example, the following relationship is defined for the Volts Mode register: 0 = 4W-WYE 1 = DELTA 2 = SINGLE 3 = DEMO 4 = 3W-WYE 5 = DELTA DIRECT For example, to set the meter to 3W-WYE mode, you write a 4 into the Volts Mode setup register (44001). See the register map for details. Numeric Setup The numeric setup parameters include: PT/CT ratios, demand intervals, digital output pulse values, unit ID, password, and RTS delay. All 9200 numeric parameters are represented in Unsigned 16-bit Integer Format. See the register map for details. Note that all parameters have bounds. For example, unit IDs must be in the range 1 to 247; any attempt to write a value outside this range will fail. See the introduction to Appendix B for a discussion on scaling. Page 11 Appendix A: CRC-16 Calculation 9200 Modbus Protocol Appendix A: CRC-16 Calculation This appendix describes the procedure for obtaining the CRC-16 error check field for a Modbus RTU frame. Procedure A frame can be considered as a continuous, serial stream of binary data (ones and zeros). The 16-bit checksum is obtained by multiplying the serial data stream by 216 (10000000000000000) and then dividing it by the generator polynomial x16+x15+x2+1, which can be expressed as the 16-bit binary number 11000000000000101. The quotient is ignored and the 16-bit remainder is the checksum, which is appended to the end of the frame. In calculating the CRC, all arithmetic operations (additions and subtractions) are performed using MODULO TWO, or EXCLUSIVE OR operation. A step-by-step example shows how to obtain the checksum for a simple Modbus RTU frame. Steps for generating the CRC-16 checksum: 1. Drop the MSB (Most Significant Bit) of the generator polynomial and reversing the bit sequence to form a new polynomial. This yields the binary number 1010 0000 0000 0001, or A0 01 (hex). 2. Load a 16-bit register with initial value FF FF (hex). 3. Exclusive OR the first data byte with the low-order byte of the 16-bit register. Store the result in the 16-bit register. 4. Shift the 16-bit register one bit to the right. 5. If the bit shifted out to the right is one, Exclusive OR the 16-bit register with the new generator polynomial, store the result in the 16-bit registers. Return to step 4. 6. If the bit shifted out to the right is zero, return to step 4. 7. Repeat steps 4 and 5 until 8 shifts have been performed. 8. Exclusive OR the next data byte with the 16-bit register. 9. Repeat steps 4 through 7 until all bytes of the frame are Exclusive Ored with the 16-bit register and shifted 8 times. 10. The content of the 16-bit register is the checksum and is appended to the end of the frame. Page 12 9200 Modbus Protocol Procedure Example: A Modbus master node requests to read register 40011 from a Modbus slave with address 100 (64 hex). As per the Modbus protocol, reading register 40011 means using the READ HOLDING REGISTERS function (03 hex) with start register 10. Initial frame: Slave Address Function Start Register 64 03 00 Step 2 Byte Bits Shifted 1 3 4 1 5a # of Registers 0A 00 Error Check (CRC-16) 01 Action 16-Bit Register Initial Value Load First Data Byte 1111 1111 1111 1111 0000 0000 0110 0100 Exclusive OR 1111 1111 1001 1011 Shift 1 bit to the Right Generator Polynomial 0111 1111 1100 1101 1010 0000 0000 0001 Exclusive OR 1101 1111 1100 1100 To be calculated Bit Shifted Out 1 4 2 Shift 1 bit to the Right 0110 1111 1110 0110 0 4 3 Shift 1 bit to the Right 0011 0111 1111 0011 0 4 4 Shift 1 bit to the Right Generator Polynomial 0001 1011 1111 1001 1010 0000 0000 0001 1 Exclusive OR 1011 1011 1111 1000 5a 4 5 Shift 1 bit to the Right 0101 1101 1111 1100 0 4 6 Shift 1 bit to the Right 0010 1110 1111 1110 0 4 7 Shift 1 bit to the Right 0001 0111 0111 1111 0 4 8 Shift 1 bit to the Right Generator Polynomial 0000 1011 1011 1111 1010 0000 0000 0001 1 Exclusive OR 1010 1011 1011 1110 Load 2nd Data Byte Exclusive OR 0000 0000 0000 0011 1010 1011 1011 1101 Shift 1 bit to the Right Generator Polynomial 0101 0101 1101 1110 1010 0000 0000 0001 Exclusive OR 1111 0101 1101 1111 Shift 1 bit to the Right Generator Polynomial 0111 1010 1110 1111 1010 0000 0000 0001 Exclusive OR 1101 1010 1110 1110 5a 7 4 2 1 5a 4 2 5a 1 1 4 3 Shift 1 bit to the Right 0110 1101 0111 0111 0 4 4 Shift 1 bit to the Right Generator Polynomial 0011 0110 1011 1011 1010 0000 0000 0001 1 Exclusive OR 1001 0110 1011 1010 5a Page 13 Procedure Step 9200 Modbus Protocol Byte Bits Shifted Action 16-Bit Register Bit Shifted Out 4 5 Shift 1 bit to the Right 0100 1011 0101 1101 0 4 6 Shift 1 bit to the Right Generator Polynomial 0010 0101 1010 1110 1010 0000 0000 0001 1 Exclusive OR 1000 0101 1010 1111 Shift 1 bit to the Right Generator Polynomial 0100 0010 1101 0111 1010 0000 0000 0001 Exclusive OR 1110 0010 1101 0110 Shift 1 bit to the Right 0111 0001 0110 1011 Load 3rd Data Byte Exclusive OR 0000 0000 0000 0000 0111 0001 0110 1011 Shift 1 bit to the Right Generator Polynomial 0011 1000 1011 0101 1010 0000 0000 0001 Exclusive OR 1001 1000 1011 0100 5a 4 7 5a 4 7 8 3 4 1 5a 1 0 1 4 2 Shift 1 bit to the Right 0100 1100 0101 1010 0 4 3 Shift 1 bit to the Right 0010 0110 0010 1101 0 4 4 Shift 1 bit to the Right Generator Polynomial 0001 0011 0001 0110 1010 0000 0000 0001 1 Exclusive OR 1011 0011 0001 0111 Shift 1 bit to the Right Generator Polynomial 0101 1001 1000 1011 1010 0000 0000 0001 Exclusive OR 1111 1001 1000 1010 5a 4 5 5a 1 4 6 Shift 1 bit to the Right 0111 1100 1100 0101 0 4 7 Shift 1 bit to the Right Generator Polynomial 0011 1110 0110 0010 1010 0000 0000 0001 1 Exclusive OR 1001 1110 0110 0011 Shift 1 bit to the Right Generator Polynomial 0100 1111 0011 0001 1010 0000 0000 0001 Exclusive OR 1110 1111 0011 0000 Load 4th Data Byte Exclusive OR 0000 0000 0000 1010 1110 1111 0011 1010 5a 4 8 5a 7 4 1 4 1 Shift 1 bit to the Right 0111 0111 1001 1101 0 4 2 Shift 1 bit to the Right Generator Polynomial 0011 1011 1100 1110 1010 0000 0000 0001 1 Exclusive OR 1001 1011 1100 1111 Shift 1 bit to the Right Generator Polynomial 0100 1101 1110 0111 1010 0000 0000 0001 Exclusive OR 1110 1101 1110 0110 Shift 1 bit to the Right 0111 0110 1111 0011 5a 4 3 5a 4 Page 14 4 1 0 9200 Modbus Protocol Step Byte 4 Procedure Bits Shifted Action 16-Bit Register Bit Shifted Out 5 Shift 1 bit to the Right Generator Polynomial 0011 1011 0111 1001 1010 0000 0000 0001 1 Exclusive OR 1001 1011 0111 1000 5a 4 6 Shift 1 bit to the Right 0100 1101 1011 1100 0 4 7 Shift 1 bit to the Right 0010 0110 1101 1110 0 4 8 Shift 1 bit to the Right 0001 0011 0110 1111 0 Load 5th Data Byte Exclusive OR 0000 0000 0000 0000 0001 0011 0110 1111 Shift 1 bit to the Right Generator Polynomial 0000 1001 1011 0111 1010 0000 0000 0001 Exclusive OR 1010 1001 1011 0110 7 5 4 1 5a 1 4 2 Shift 1 bit to the Right 0101 0100 1101 1011 0 4 3 Shift 1 bit to the Right Generator Polynomial 0010 1010 0110 1101 1010 0000 0000 0001 1 Exclusive OR 1000 1010 0110 1100 5a 4 4 Shift 1 bit to the Right 0100 0101 0011 0110 0 4 5 Shift 1 bit to the Right 0010 0010 1001 1011 0 4 6 Shift 1 bit to the Right Generator Polynomial 0001 0001 0100 1101 1010 0000 0000 0001 1 Exclusive OR 1011 0001 0100 1100 5a 4 7 Shift 1 bit to the Right 0101 1000 1010 0110 0 4 8 Shift 1 bit to the Right 0010 1100 0101 0011 0 Load 6th Data Byte Exclusive OR 0000 0000 0000 0001 0010 1100 0101 0010 7 6 4 1 Shift 1 bit to the Right 0001 0110 0010 1001 0 4 2 Shift 1 bit to the Right Generator Polynomial 0000 1011 0001 0100 1010 0000 0000 0001 1 Exclusive OR 1010 1011 0001 0101 Shift 1 bit to the Right Generator Polynomial 0101 0101 1000 1010 1010 0000 0000 0001 Exclusive OR 1111 0101 1000 1011 Shift 1 bit to the Right Generator Polynomial 0111 1010 1100 0101 1010 0000 0000 0001 Exclusive OR 1101 1010 1100 0100 5a 4 3 5a 4 4 5a 1 1 4 5 Shift 1 bit to the Right 0110 1101 0110 0010 0 4 6 Shift 1 bit to the Right 0011 0110 1011 0001 0 Page 15 Pseudocode For CRC-16 Generation Step Byte 4 Bits Shifted Action 16-Bit Register Bit Shifted Out 7 Shift 1 bit to the Right Generator Polynomial 0001 1011 0101 1000 1010 0000 0000 0001 1 Exclusive OR 1011 1011 0101 1001 Shift 1 bit to the Right Generator Polynomial 0101 1101 1010 1100 1010 0000 0000 0001 Exclusive OR 1111 1101 1011 1100 RESULT Hex FD 5a 4 9200 Modbus Protocol 8 5a 1 Hex AD The frame completed with the CRC-16 checksum is as follows: Slave Address Function Start Register 64 03 00 # of Registers 0A 00 Error Check (CRC-16) 01 AD FD Pseudocode For CRC-16 Generation For users familiar with computer programming, the following is the pseudocode for calculating the 16-bit Cyclic Redundancy Check. Initialize a 16-bit register to FFFF Hex Initialize the generator polynomial to A001 Hex FOR n=1 to # of bytes in packet BEGIN XOR nth data byte with the 16-bit register FOR bits_shifted = 1 to 8 BEGIN SHIFT 1 bit to the right IF (bit shifted out EQUAL 1) XOR generator polynomial with the 16-bit register and store result in the 16-bit register END END The resultant 16-bit register contains the CRC-16 checksum. Page 16 9200 Modbus Protocol Appendix B: ION / Modbus Map Appendix B: ION / Modbus Map This appendix contains the ION/Modbus register map for the 9200 meter. In the following Modbus map many numeric measurements are scaled. Scaling is either fixed or programmable. For an example of fixed scaling, suppose that the frequency register 40115 contains the value 5987. Since this register is scaled by “x100” the actual measured value is 59.87 Hz. For an example of programmable scaling, suppose that the meter Vln a value is 480.1. If the PVS scaling is set to “x10” (default), then register 40100 will contain a value of 4801. If the PVS scaling is set to “0.1,” then register 40100 will contain a value of 48. The meter supports programmable scaling for voltage (PVS), current (PCS), neutral current (PnS), and power (PPS). Modbus Addr Measurement (9200 Megawatt meters) Measurement (all other 9200 meters) Format Scale 40001 serial number serial number UINT32 x1 40003 firmware revision firmware revision UINT16 x1 40004 oem identification oem identification UINT16 x1 See note 2. 40005 meter options meter options UINT32 x1 See note 3. 40007 # meter power ups # meter power ups UINT16 x1 40008 # peak demand resets # peak demand resets UINT16 x1 40009 meter on-time meter on-time UINT32 x1 40011 # flash erase cycles # flash erase cycles UINT32 x1 40013 device type device type UINT16 x1 40014 Reserved Reserved 40015 demand interval down counter demand interval down counter UINT16 x1 40016 40099 Reserved Reserved 40100 kVln a Vln a UINT16 PVS x10 See notes 6 & 7. 40101 kVln b Vln b UINT16 PVS x10 See note 6. 40102 kVln c Vln c UINT16 PVS x10 See note 6. 40103 kVln avg Vln avg UINT16 PVS x10 See note 6. 40104 kVll ab Vll ab UINT16 PVS x10 40105 kVll bc Vll bc UINT16 PVS x10 40106 kVll ca Vll ca UINT16 PVS x10 40107 kVll avg Vll avg UINT16 PVS x10 40108 Ia Ia UINT16 PCS x10 Default Scale Description See note 1. See note 4. See note 5. See note 8. Page 17 Appendix B: ION / Modbus Map 9200 Modbus Protocol Modbus Addr Measurement (9200 Megawatt meters) Measurement (all other 9200 meters) Format Scale Default Scale 40109 Ib Ib UINT16 PCS x10 40110 Ic Ic UINT16 PCS x10 40111 I avg I avg UINT16 PCS x10 40112 I demand I demand UINT16 PCS x10 40113 I peak demand I peak demand UINT16 PCS x10 40114 I4 I4 UINT16 PnS x10 See note 9. 40115 Frequency Frequency INT16 x100 40116 PF sign total PF sign total INT16 x100 40117 PF sign a PF sign a INT16 x100 40118 PF sign b PF sign b INT16 x100 40119 PF sign c PF sign c INT16 x100 40120 MW total kW total INT16 PPS x1 See note 10. 40121 MVAR total kVAR total INT16 PPS x1 40122 MVA total kVA total INT16 PPS x1 40123 MW a kW a INT16 PPS x1 40124 MW b kW b INT16 PPS x1 40125 MW c kW c INT16 PPS x1 40126 MVAR a kVAR a INT16 PPS x1 40127 MVAR b kVAR b INT16 PPS x1 40128 MVAR c kVAR c INT16 PPS x1 40129 MVA a kVA a INT16 PPS x1 40130 MVA b kVA b INT16 PPS x1 40131 MVA c kVA c INT16 PPS x1 40132 MW demand kW demand INT16 PPS x1 40133 MW peak demand kW peak demand INT16 PPS x1 40134 MVAR demand kVAR demand INT16 PPS x1 40135 MVA demand kVA demand INT16 PPS x1 40136 MVAR peak demand kVAR peak demand INT16 PPS x1 40137 MVA peak demand kVA peak demand INT16 PPS x1 40138 MWh del kWh del UINT32 x1 40140 MWh rec kWh rec UINT32 x1 40142 MVARh del kVARh del UINT32 x1 40144 MVARh rec kVARh rec UINT32 x1 40146 MVAh del+rec kVAh del+rec UINT32 x1 Page 18 Description See note 11. 9200 Modbus Protocol Appendix B: ION / Modbus Map Modbus Addr Measurement (9200 Megawatt meters) Measurement (all other 9200 meters) Format Scale 40148 V1 THD V1 THD UINT16 x10 40149 V2 THD V2 THD UINT16 x10 40150 V3 THD V3 THD UINT16 x10 40151 I1 THD I1 THD UINT16 x10 40152 I2 THD I2 THD UINT16 x10 40153 I3 THD I3 THD UINT16 x10 40154 I a demand I a demand UINT16 PCS x10 40155 I b demand I b demand UINT16 PCS x10 40156 I c demand I c demand UINT16 PCS x10 40157 I a peak demand I a peak demand UINT16 PCS x10 40158 I b peak demand I b peak demand UINT16 PCS x10 40159 I c peak demand I c peak demand UINT16 PCS x10 40160 MWh a del kWh a del UINT32 x1 40162 MWh b del kWh b del UINT32 x1 40164 MWh c del kWh c del UINT32 x1 40166 MWh a rec kWh a rec UINT32 x1 40168 MWh b rec kWh b rec UINT32 x1 40170 MWh c rec kWh c rec UINT32 x1 40172 MVARh a del kVARh a del UINT32 x1 40174 MVARh b del kVARh b del UINT32 x1 40176 MVARh c del kVARh c del UINT32 x1 40178 MVARh a rec kVARh a rec UINT32 x1 40180 MVARh b rec kVARh b rec UINT32 x1 40182 MVARh c rec kVARh c rec UINT32 x1 40184 MVAh a kVAh a UINT32 x1 40186 MVAh b kVAh b UINT32 x1 40188 MVAh c kVAh c UINT32 x1 40189 40499 Reserved Reserved 40500 Expansion, SnapOn 1, 25 regs Expansion, SnapOn 1, 25 regs UINT16 x1 40700 Expansion, SnapOn 2, 25 regs Expansion, SnapOn 2, 25 regs UINT16 x1 Default Scale Description See note 11. Page 19 Appendix B: ION / Modbus Map 9200 Modbus Protocol Modbus Addr Measurement (9200 Megawatt meters) Measurement (all other 9200 meters) Format Scale 41138 MWh del kWh del UINT32 x1 41140 MWh rec kWh rec UINT32 x1 41142 MVARh del kVARh del UINT32 x1 41144 MVARh rec kVARh rec UINT32 x1 41146 MVAh del+rec kVAh del+rec UINT32 x1 41160 MWh a del kWh a del UINT32 x1 41162 MWh b del kWh b del UINT32 x1 41164 MWh c del kWh c del UINT32 x1 41166 MWh a rec kWh a rec UINT32 x1 41168 MWh b rec kWh b rec UINT32 x1 41170 MWh c rec kWh c rec UINT32 x1 41172 MVARh a del kVARh a del UINT32 x1 41174 MVARh b del kVARh b del UINT32 x1 41176 MVARh c del kVARh c del UINT32 x1 41178 MVARh a rec kVARh a rec UINT32 x1 41180 MVARh b rec kVARh b rec UINT32 x1 41182 MVARh c rec kVARh c rec UINT32 x1 41184 MVAh a kVAh a UINT32 x1 41186 MVAh b kVAh b UINT32 x1 41188 MVAh c kVAh c UINT32 x1 Page 20 Default Scale Description See note 12. 9200 Modbus Protocol Read-Write Configuration Map Read-Write Configuration Map Modbus Addr Configuration Parameter (all 9200 meters) Format Scale Default Description 44000 Configuration via display password UINT16 x1 0 0 – 9999 5= Delta direct 0 = 4W (4-Wire WYE) 1 = dELt (Delta) 2 = 2W (Single Phase) 3 = dEM (Demonstration) 4 = 3W (3-Wire WYE) 5 = dELd (Delta direct) 44001 Volts Mode Enumerated 44002 PT Primary UINT16 x1 480 44003 PT Secondary UINT16 x1 480 44004 CT Primary UINT16 x1 400 44005 CT Secondary UINT16 x1 5 44006 V1 Polarity 44007 V2 Polarity 44008 V3 Polarity 44009 I1 Polarity 44010 I2 Polarity 44011 I3 Polarity 44012 Programmable Voltage Scale (PVS) 44013 Programmable Current Scale (PIS) Enumerated 0 = Normal 1 – 65535 0 = nor (Normal) 1 = inv (Inverted) 3=1 0 = 0.001 1 = 0.01 2 = 0.1 3=1 4 = 10 5 = 100 6 = 1000 x1 15 1 – 60 minutes UINT16 x1 1 1–5 Kt, Digital Output #1 UINT16 x10 44019 Kt, Digital Output #2 UINT16 x10 1.0 0.1 - 999.9 44021 Output Mode, Digital Output #1 0 = kWh 44022 Output Mode, Digital Output #2 0 = kWh Del. 1 = kVAh 2 = kVARh Del. 3 = Ext1 4 = Ext2 5 = kWh Rec. 6 = kVARh Rec. See note 13. 4 = 10 Enumerated 44014 Programmable Neutral Current Scale (PnS) 44015 Programmable Power Scale (PPS) 44016 Demand Sub Interval UINT16 44017 Demand #Sub Intervals 44018 Enumerated 2 = kVARh 44024 Baud Rate Enumerated 3 = 9600bps 0 = 1200bps 1 = 2400bps 2 = 4800bps 3 = 9600bps 4 = 19200bps 44025 Protocol Enumerated 1= MODBUS 0 = PML 1 = MODBUS See note 14. Page 21 Read-Write Control Map 9200 Modbus Protocol Modbus Addr Configuration Parameter (all 9200 meters) Format Scale Default Description 44026 Unit ID UINT16 x1 100 plus the last 2 digits of the Serial Number 1 – 247 44027 RTS Delay UINT16 x1 20 0 – 1000 milliseconds See note 15. 44028 Display Scroll Time UINT16 x1 0 0 – 30 seconds See note 16. 44029 Display Refresh Period UINT16 x1 2 1 – 6 seconds See note 17. 44030 PT Scale Enumerated 0 = x1 0 = x1 1 = x1000 Read-Write Control Map Modbus Addr18 Control Parameter (all 9200 meters) Format Scale Description 42001 Energy Reset UINT16 x1 Reset MWh, MVAh, and MVARh to 0 (Megawatt meters) Reset kWh, kVAh, and kVARh to 0 (all other models) 42002 Peak Power Demand Reset UINT16 x1 Reset MW, MVA, and MVAR peak demand to 0 (Megawatt meters) Reset kW, kVA, and kVAR peak demand to (all other models) 42003 Peak Current Demand Reset UINT16 x1 Reset I peak demand. 42004 Digital Output #1 UINT16 x1 42005 Digital Output #2 UINT16 x1 Refer to “Digital Output Control” on page 10. Notes 1 Format is YYMM##### where YY and MM represent the manufacture date. 2 Identifies the Original Equipment Manufacturer (OEM). 3 Options codes that identify meter options. To see a table that cross-references Options Cards and options codes, refer to the 9200 Options Card Retrofit Instructions. 4 Number of seconds that the meter has been powered up. 5 Device identification. 6 When Volts Mode is set to Delta or Delta Direct, these registers are invalid. 7 PVS = Programmable Voltage Scale. Ensure that scaling is compatible with the expected register value; this provides maximum resolution and prevents register overflow. 8 PCS = Programmable Current Scale. Ensure that scaling is compatible with the expected register value; this provides maximum resolution and prevents register overflow. 9 PnS = Programmable Neutral Current Scale. Ensure that scaling is compatible with the expected register value; this provides maximum resolution and prevents register overflow. 10 PPS = Programmable Power Scale. Ensure that scaling is compatible with the expected register value; this provides maximum resolution and prevents register overflow. Page 22 11 When it is read from that address the Low Order Word is fetched first. 12 These registers are duplicate of other UINT32 read-only registers differing only in that the High Order Word is fetched first. 9200 Modbus Protocol Read-Write Control Map 13 Digital output modes are: MW pulsing, MVAR pulsing, MVA pulsing, and digital control (Megawatt meters) or kW pulsing, kVAR pulsing, kVA pulsing, and digital control (all other models). For digital output control information, refer to “Digital Output Control” on page 10. 14 The PML protocol is an ION compatible protocol used when other ACCESS devices are sharing a RS485 network. 15 The RTS Delay parameter defines the delay between the 9200 becoming ready to transmit data on the serial port, and the 9200 transmitting the data. 16 Number of seconds that a display is shown before scrolling to the next, 0 = no scrolling (disabled). 17 Number of seconds that a measurement value is held on the display before being refreshed; limited to 1-6 seconds. 18 To use the Read-Write Control Map, it is recommended that your meter has firmware version 202 or later. For detailed information, contact Customer Service. Page 23 ">
/
Preuzimanje
Samo prijateljski podsetnik. Dokument možete pogledati ovde. Ali što je najvažnije, naš AI ga je već pročitao. Može da objasni složene stvari jednostavnim rečima, odgovori na vaša pitanja na bilo kom jeziku i pomogne vam da brzo navigirate čak i najdužim ili najkomplikovanijim dokumentima.
Reklama