Juniper Networks M20 Internet Backbone Router Quick reference
PDF
مستند
إعلان
إعلان
M20 Internet Backbone Router Fan tray assemblies (3) Cable management system Routing Engines Rear Routing Engine panel SSB0 SSB1 Craft interface FPC0 1112 FPC1 FPC2 1111 PICs (on FPCs) FPC3 Cable management system Power supplies Front View Rear View M20 Router Major Hardware Components Component Flexible PIC Concentrators (FPCs) Physical Interface Cards (PICs) System and Switch Boards (SSBs) Routing Engine Power supplies Cooling system Craft interface Quantity 1–4 1–4 per FPC 1–2 1–2 2 AC or 2 DC 3 fan trays and 1 rear Routing Engine fan 1 Function Connects PICs to router components, houses shared memory Provides interfaces to various network media Redundant – – Performs route lookups, manages shared memory, – transfers control packets Handles routing protocols, maintains – routing tables Distributes voltages to components Yes Cools router components Yes Displays status and allows you to perform control functions – Field-replaceable Hot-removable Hot-insertable From removed FPC Hot-pluggable Offline Button Yes Yes – Hot-pluggable Yes Hot-removable Hot-insertable Hot-removable Hot-insertable – Hot-removable Hot-insertable – – Hot-removable and hot-insertable—Can remove and replace without powering down the router or disrupting routing functions. Hot-pluggable—Can remove without powering down the router, but forwarding is interrupted, or router switches to warm shutdown mode, until replacement is installed. M 2 0 R o u t e r P h ys i c a l S p e c i f i c a t i o n s Dimensions Weight Required clearances Hardware 14 in. (36 cm) high x 19 in. (48.3) wide x 21 in. (54 cm) deep 80 lb (36 kg) minimum configuration 134 lb (61 kg) maximum configuration 19 in. (48 cm) front and rear; 6 in. (15.2 cm) each side JUNOS Release 4.3 M20 Internet Backbone Router M20 Router Power Supply Specifications Specification Maximum power consumption Input voltage Input line frequency Input current rating Output voltages Power and grounding cords and cables AC 750 W 90 through 264 VAC operating range 47–63 Hz, autoranging 13 A @ 90 V +3.3 V; +5 V; +2.5 V; +12 V; +24 V Country-specific; see M20 Internet Backbone Router Hardware Installation Guide DC 750 W –40 through –72 VDC operating range – 24 A @ –48 V (typical) +3.3 V; +5 V; +2.5 V; +12 V; +24 V 4 or 6 AWG wire cables with dual hole 1/4 –20 UNC terminal studs @ 15.86 mm (0.625 in.) centers M20 Router LEDs Component FPCs PICs SSBs Routing Engine Power supplies Alarm LEDs Red alarm Yellow alarm LED Green OK Amber FAIL 1 LED per port, with 4 states: Red, Green, Amber, Off Blue MASTER Green ONLINE Amber OFFLINE 2 Green STATUS Blue MASTER Green ONLINE Amber OFFLINE Green OK Red FAIL Large circular red Large triangular amber Location Craft interface PIC faceplate SSB faceplate Craft interface and Routing Engine panel Power supply faceplate Craft interface Craft interface Ta k i n g C o m p o n e n t s O f f l i n e Component FPC PIC SSB Routing Engine Procedure 1. Press the FPC offline button, located on the right side of the craft interface, for the appropriate FPC. 2. Press and hold the button until the amber FAIL LED lights (about 5 seconds). Remove the FPC containing the PIC (this will take all interfaces on the removed FPC offline). 1. Press the SSB offline button on the SSB faceplate. 2. Press and hold the button until the amber SSB OFFLINE LED lights (about 5 seconds). 1. Press the Routing Engine (RE0 or RE1) offline button on the craft interface or on the Routing Engine panel. 2. Press and hold the button until the amber OFFLINE LED lights. You can take the backup Routing Engine offline without interrupting the functioning of the router. If you take the master Routing Engine offline, the router reboots with the other Routing Engine functioning as master. The routing and forwarding functions are interrupted during this process. M20 Internet Backbone Router System Architecture Routing Engine The router has two major architectural components: the Routing Engine, which provides Layer 3 routing services and network management; and the Packet Forwarding Engine, which provides packet switching, route lookups, and packet forwarding. The Routing Engine and Packet Forwarding Engine operate independently, but constantly communicate through a 100-Mbps link, as illustrated in the figure at the right. Packets in Packet Forwarding Engine PIC Packet Flow through the Packet Forwarding Engine To ensure efficient packet flow through the system, data packet forwarding is handled by ASICs on the hardware components. The figure at the right shows the sequence of packet flow through the Packet Forwarding Engine. PIC Controller Controller SSB FPC FPC Internet processor Packet in Packets out 1244 100-Mbps link I/O manager Distributed Buffer Manager I/O manager Packet out = ASIC Midplane Routing Engine Architecture The Routing Engine handles all the routing protocol processes as well as processes controlling interfaces, router components, system management, and user access. These processes run on top of a kernel that interacts with the Packet Forwarding Engine. JUNOS software System management processes Routing protocols Kernel 1243 Routing Engine Control functions System processes Operating system 1164 Intel-based PCI platform Routing protocol process Control Packet Handling Forwarding table updates Routing Engine Routing protocol packets from network Forwarding table Packets in Packet Forwarding Engine Packets out 1240 The Routing Engine constructs and maintains routing tables, and derives a table of active routes, called the forwarding table, from the routing tables. The forwarding table is then copied into the Packet Forwarding Engine. M20 Internet Backbone Router General Safety Guidelines ■ Only trained and qualified personnel should install or replace the router. ■ Perform only the procedures described in the M20 Internet Backbone Router Hardware Installation Guide. Other services should be performed by authorized service personnel only. ■ For protection against shock hazard, verify that all power cables are disconnected before servicing the router. ■ Before installing the router, read the guidelines in the “Prepare the Site” section of the M20 Internet Backbone Router Hardware Installation Guide to make sure that the site meets power, environmental, and clearance requirements for the router. ■ Manually installing the router requires two people to lift the chassis and a third person to secure the mounting screws. Before lifting the chassis, and remove components as described in the M20 Internet Backbone Router Hardware Installation Guide. To prevent injury, keep your back straight and lift with your legs, not your back. Do not attempt to lift the chassis with the handles on the power supplies. ■ Do not work on the router or connect or disconnect cables during electrical storms. ■ Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments. ■ Operate the router only when the grounding wire is connected. ■ Use copper conductors only. ■ Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Doing so could cause electrical shock. ■ Do not open or remove chassis covers or sheet metal parts when instructions are not provided in the M20 Internet Backbone Router Hardware Installation Guide. Doing so could cause severe electrical shock. ■ Do not push or force any objects through any of the openings in the chassis frame. Doing so could result in electrical shock or fire. ■ Avoid spilling liquid into the router chassis or onto any router components. Doing so could cause electrical shock or damage the router. ■ Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. ■ Failure to observe these safety warnings could result in serious physical injury. Agency Approvals Category Safety EMI Immunity NEBS ETSI Approval CSA C22.2 No. 950 ■ UL 1950 ■ EN 60950, Safety of Information Technology Equipment ■ EN 60825-1 Safety of Laser Products–Part 1: Equipment Classification, Requirements and User’s Guide ■ EN 60825-2 Safety of Laser Products–Part 2: Safety of Optical Fibre Communication Systems ■ AS 3548 Class A (Australia) ■ EN 55022 Class A emissions (Europe) ■ FCC Class A (USA) ■ VCCI Class A (Japan) ■ EN 61000-3-2 Power Line Harmonics ■ EN 61000-4-2 ESD ■ EN 61000-4-3 Radiated Immunity ■ EN 61000-4-4 EFT ■ EN 61000-4-5 Surge ■ EN 61000-4-6 Low Frequency Common Immunity ■ EN 61000-4-11 Voltage Dips and Sags The router has been tested to meet the following standards: ■ GR-63-Core: NEBS, Physical Protection ■ GR-1089-Core: EMC and Electrical Safety for Network Telecommunications Equipment ■ SR-3580 NEBS Criteria Levels (Level 3 Compliance) ■ ETS-300386-2 Switching Equipment ■ w w w. j u n i p e r. n e t For support issues, contact the Juniper Networks Technical Assistance Center (JTAC) at 1-888-314-JTAC (within the United States) or 408-745-2121 (from outside the United States). For other contact information, refer to www.juniper.net/contactus.html. Juniper Networks is a registered trademark of Juniper Networks, Inc. Internet Processor, Internet Processor II, JUNOS, JUNOScript, M5, M10, M20, M40, and M160 are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks may be the property of their respective owners. All specifications are subject to change without notice. Copyright © 2001, Juniper Networks, Inc. All rights reserved. Printed in USA. ">
/
تنزيل
مجرد تذكير ودي. يمكنك عرض المستند هنا. ولكن الأهم من ذلك، أن الذكاء الاصطناعي لدينا قد قرأه بالفعل. يمكنه شرح الأشياء المعقدة بعبارات بسيطة، والإجابة على أسئلتك بأي لغة، ومساعدتك في التنقل بسرعة حتى في أطول المستندات أو أكثرها تعقيدًا.
إعلان