Juniper T4000 - Hardware Manual
Annonce
Annonce
T4000 Core Router
Hardware Guide
Published: 2013-08-28
Copyright © 2013, Juniper Networks, Inc.
Juniper Networks, Inc.
1194 North Mathilda Avenue
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
This product includes the Envoy SNMP Engine, developed by Epilogue Technology, an Integrated Systems Company. Copyright © 1986-1997,
Epilogue Technology Corporation. All rights reserved. This program and its documentation were developed at private expense, and no part of them is in the public domain.
This product includes memory allocation software developed by Mark Moraes, copyright © 1988, 1989, 1993, University of Toronto.
This product includes FreeBSD software developed by the University of California, Berkeley, and its contributors. All of the documentation and software included in the 4.4BSD and 4.4BSD-Lite Releases is copyrighted by the Regents of the University of California. Copyright ©
1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994. The Regents of the University of California. All rights reserved.
GateD software copyright © 1995, the Regents of the University. All rights reserved. Gate Daemon was originated and developed through release 3.0 by Cornell University and its collaborators. Gated is based on Kirton’s EGP, UC Berkeley’s routing daemon (routed), and DCN’s
HELLO routing protocol. Development of Gated has been supported in part by the National Science Foundation. Portions of the GateD software copyright © 1988, Regents of the University of California. All rights reserved. Portions of the GateD software copyright © 1991, D.
L. S. Associates.
This product includes software developed by Maker Communications, Inc., copyright © 1996, 1997, Maker Communications, Inc.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United
States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312,
6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.
T4000 Core Router Hardware Guide
Copyright © 2013, Juniper Networks, Inc.
All rights reserved.
Revision History
May 2013—For Junos OS Release 13.1, added support for a new rear fan tray (model number FAN-R-TXP-3D-LCC) and TXP-LCC-3D SIB
(model number SIB-TXP-3D-LCC) for connection to TX Matrix Plus routers.
January 2013—Updated DC power connections, power configuration, and power management information.
October 2012—Added registering your upgrade.
September 2012—For Junos OS Release 12.1R2, added support of graceful routing engine switchover (GRES) and nonstop active routing
(NSR). For Junos OS Release 12.2, added support for upgrading from a T640 or T1600 router without a reboot.
March 2012—Initial release.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at http://www.juniper.net/support/eula.html
. By downloading, installing or using such software, you agree to the terms and conditions of that EULA.
ii Copyright © 2013, Juniper Networks, Inc.
Table of Contents
Part 1
Chapter 1
Chapter 2
Chapter 3
About the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Junos OS Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii
Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii
Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv
T4000 Router Overview
T4000 Router Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
T4000 Router Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
T4000 Router System Architecture Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 7
System Architecture Description for T Series Routers . . . . . . . . . . . . . . . . . . . . . . . 7
Routing Engine Functions for T Series Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Packet Forwarding Engine Architecture for T Series Routers . . . . . . . . . . . . . . . . . . 9
Packet Forwarding Engine Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
T4000 Hardware Components Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
T4000 Hardware Component Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
T4000 Component Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
T4000 Chassis Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
T4000 Midplane Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
T4000 Cable Management System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
T4000 Cooling System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Power Supply Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
T4000 Craft Interface Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
T4000 Craft Interface Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Craft Interface Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Craft Interface LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
T4000 Craft Interface LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Alarm LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
FPC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Host Subsystem LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Copyright © 2013, Juniper Networks, Inc.
iii
T4000 Router Hardware Guide iv
SIB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
T4000 Connector Interface Panel (CIP) Overview . . . . . . . . . . . . . . . . . . . . . . . . . 27
T4000 Connector Interface Panel (CIP) Description . . . . . . . . . . . . . . . . . . . 27
T4000 Connector Interface Panel (CIP) Components . . . . . . . . . . . . . . 27
Management Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
T4000 Alarm Relay Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
T4000 Connector Interface Panel (CIP) LEDs . . . . . . . . . . . . . . . . . . . . . . . . 29
T4000 FPC Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
T4000 FPC Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
T4000 FPC Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
T4000 FPC Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
T4000 FPC Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Identifying the FPCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
FPC Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
T4000 FPCs Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
T4000 Host Subsystem Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
T4000 Host Subsystem Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
T4000 Control Board Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
T4000 Control Board Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
T4000 LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
T4000 LCC-CB Control Board LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
T4000 Routing Engine Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
T4000 Routing Engine Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
T4000 RE-C1800 Routing Engine Description . . . . . . . . . . . . . . . . . . . . 40
T4000 RE-C1800 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
T4000 PIC Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
T4000 Power System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
T4000 Power System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Power Supply Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Power Supply Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Supported Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Power Supply Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
T4000 Six-Input DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
T4000 Switch Interface Board (SIB) Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
T4000 Switch Interface Board (SIB) Description . . . . . . . . . . . . . . . . . . . . . . 46
T4000-SIB Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
T4000 TXP-LCC-3D SIB Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
T4000 SIB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
T4000 SONET Clock Generators (SCGs) Overview . . . . . . . . . . . . . . . . . . . . . . . 49
T4000 SONET Clock Generators (SCGs) Description . . . . . . . . . . . . . . . . . . 49
SCG Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SCG Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SCG Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Supported SCGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SCG Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
T4000 SONET Clock Generators (SCGs) LEDs . . . . . . . . . . . . . . . . . . . . . . . . 51
Copyright © 2013, Juniper Networks, Inc.
Table of Contents
Part 2
Chapter 4
Chapter 5
Chapter 6
Chapter 7
Chapter 8
Chapter 9
Chapter 10
T4000 Router Initial Installation
T4000 Router Installation Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Overview of Installing the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Preparing for T4000 Router Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Overview of Preparing the Site for the T4000 Router . . . . . . . . . . . . . . . . . . . . . . 57
Rack Requirements for the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
T4000 Clearance Requirements for Airflow and Hardware Maintenance . . . . . . 59
Unpacking the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Overview of Unpacking the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Tools and Parts Required to Unpack the T4000 Router . . . . . . . . . . . . . . . . . . . . . 61
Unpacking the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Verifying the T4000 Router Parts Received . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Installing the T4000 Router Mounting Hardware . . . . . . . . . . . . . . . . . . . . . 67
Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet . . . . . 67
Installing Cage Nuts, if Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Installing the Large Mounting Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Installing the Small Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Installing the Spacer Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Installing the T4000 Mounting Hardware for an Open-Frame Rack . . . . . . . . . . . 70
Installing the Cage Nuts, if Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Installing the Large Mounting Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Removing the Center-Mounting Brackets from the Chassis . . . . . . . . . . . . . . 72
Removing the Spacer Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Installing the T4000 Router into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Overview of Installing the T4000 Router into a Rack . . . . . . . . . . . . . . . . . . . . . . . 75
Installing the T4000 Router Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . 77
Overview of Installing a T4000 Router Using a Mechanical Lift . . . . . . . . . . . . . . 77
Tools Required to Install the T4000 Router Using a Mechanical Lift . . . . . . . . . . . 77
Installing the T4000 Router Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . . 78
Removing the T4000 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Attaching the T4000 Installation Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Installing the T4000 Chassis in a Rack or Cabinet Using a Mechanical
Lift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Removing the T4000 Installation Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Reinstalling the T4000 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Installing the T4000 Router Without a Mechanical Lift . . . . . . . . . . . . . . . . 85
Overview of Installing a T4000 Router Without a Mechanical Lift . . . . . . . . . . . . 85
Tools Required to Install the T4000 Router Without a Mechanical Lift . . . . . . . . 86
Removing T4000 Components from the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . 86
Removing the T4000 DC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Removing the T4000 SIBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Removing the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Removing the T4000 SCGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Removing the T4000 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Removing the T4000 Front Cable Management System . . . . . . . . . . . . . . . . 94
Copyright © 2013, Juniper Networks, Inc.
v
T4000 Router Hardware Guide vi
Chapter 11
Chapter 12
Chapter 13
Chapter 14
Removing the T4000 Front Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Removing the T4000 FPCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Installing the T4000 Chassis in a Rack or Cabinet Manually . . . . . . . . . . . . . . . . 98
Reinstalling the T4000 Components in the Chassis . . . . . . . . . . . . . . . . . . . . . . . 101
Reinstalling the Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Reinstalling the T4000 SCGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Reinstalling the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Reinstalling the T4000 SIBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Reinstalling the Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Reinstalling the FPCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Reinstalling T4000 Front Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Reinstalling the T4000 Front Cable Management System . . . . . . . . . . . . . 108
Grounding the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Overview of Grounding the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Tools and Parts Required to Ground the T4000 Router . . . . . . . . . . . . . . . . . . . . 109
Connecting the T4000 Grounding Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Connecting the T4000 Router to External Devices . . . . . . . . . . . . . . . . . . . . 111
Overview of Connecting the T4000 Router to External Devices . . . . . . . . . . . . . . 111
Tools and Parts Required to Connect the T4000 Router to External Devices . . . 112
Connecting the T4000 Router to a Management Console or Auxiliary Device . . . 112
Connecting the T4000 Router to an External Alarm-Reporting Device . . . . . . . . 114
Connecting the T4000 Router to an External Clocking Device . . . . . . . . . . . . . . . 115
Connecting PIC Cables to the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Connecting the T4000 Router to a Management Ethernet Device . . . . . . . . . . . 118
Providing Power to the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Tools and Parts Required to Provide Power to the T4000 Router . . . . . . . . . . . . . 121
Connecting Power to the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Connecting DC Power to the T4000 Router (Six 60-A Inputs) . . . . . . . . . . . 122
Connecting DC Power to the T4000 Router (Five 60-A Inputs) . . . . . . . . . . 126
Connecting DC Power to the T4000 Router (Four 60-A Inputs) . . . . . . . . . 130
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A Inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Powering On the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Powering Off the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Configuring Junos OS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Initially Configuring the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Preparing to Configure the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Entering Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Configuring User Accounts and Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Configuring System Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Committing the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Configuring DC Power on a T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Configuring DC Power on a T4000 Router (Five 60-A Cables on a Six-Input
DC Power Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Configuring DC Power on a T4000 (Four 60-A Cables on a Six-Input DC
Power Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Copyright © 2013, Juniper Networks, Inc.
Table of Contents
Part 3
Chapter 15
Chapter 16
Part 4
Chapter 17
Configuring DC Power on a T4000 (Three 80-A Cables on a Six-Input DC
Power Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Upgrading to a T4000 Router from a T640 or T1600 Router
Preparing to Upgrade to a T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Overview of Preparing to Upgrade to a T4000 Router . . . . . . . . . . . . . . . . . . . . . 155
Checking the Hardware Version of T640 or T1600 Components . . . . . . . . . . . . 156
Checking the Hardware Version of the Control Boards . . . . . . . . . . . . . . . . . 156
Checking the Hardware Version of the Routing Engines . . . . . . . . . . . . . . . . 158
Checking the Hardware Version of the Rear Fan Tray . . . . . . . . . . . . . . . . . . 160
Checking the Hardware Version of the FPCs . . . . . . . . . . . . . . . . . . . . . . . . . 162
T4000 Upgrade Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
Upgrading to a T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Overview of Upgrading to a T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Upgrading Hardware Components on the T640 or T1600 Router . . . . . . . . . . . 168
Preparing to Upgrade the T640 or T1600 Components . . . . . . . . . . . . . . . . 168
Upgrade to the Six-Input DC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . 169
Upgrade the Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Upgrading the Host Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Removing Unsupported FPCs and PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Verify That Components Supported by the T4000 Router Are Installed . . . . 171
Upgrading to T4000 SIBs with Junos OS Release 12.1 . . . . . . . . . . . . . . . . . . . . . . 172
Upgrading to T4000 SIBs Online with Junos OS Release 12.2 and Later . . . . . . . 173
Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router . . . . 175
Registering Your T4000 Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Maintenance, Troubleshooting, and Replacement Procedures
Maintaining T4000 Router Hardware Components . . . . . . . . . . . . . . . . . . . 179
Tools and Parts Required to Maintain the T4000 Hardware Components . . . . . 179
Routine Maintenance Procedures for the T4000 Router . . . . . . . . . . . . . . . . . . . 179
Maintaining T4000 Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . 180
Maintaining the T4000 Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Maintaining the T4000 Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Maintaining the T4000 Routing Engine and Control Boards . . . . . . . . . . . . . . . . 182
Maintaining the T4000 Host Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Maintaining the T4000 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Maintaining the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Maintaining T4000 FPCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Maintaining T4000 PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Maintaining PIC Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Maintaining the T4000 Power System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Maintaining the T4000 SIBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Maintaining the T4000 SCGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Copyright © 2013, Juniper Networks, Inc.
vii
T4000 Router Hardware Guide viii
Chapter 18
Chapter 19
Troubleshooting T4000 Router Hardware Components . . . . . . . . . . . . . . 189
T4000 Troubleshooting Resources Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
T4000 LED Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Craft Interface LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Component LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
T4000 Alarm Messages Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Chassis Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Interface Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Troubleshooting the T4000 Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Troubleshooting the T4000 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Troubleshooting the T4000 Host Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Troubleshooting the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Troubleshooting the T4000 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Troubleshooting the T4000 FPCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Troubleshooting the T4000 Power System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Troubleshooting the T4000 PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Troubleshooting the T4000 SCGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Troubleshooting the T4000 SIBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Replacing T4000 Router Hardware Components . . . . . . . . . . . . . . . . . . . . 215
T4000 Field-Replaceable Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Tools and Parts Required for Replacing T4000 Hardware Components . . . . . . . 217
Replacing a T4000 Front Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Removing the T4000 Front Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Installing the T4000 Front Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Replacing a T4000 Rear Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Removing a Rear T4000 Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Installing the T4000 Rear Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Replacing the T4000 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Removing the T4000 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Installing the T4000 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Replacing a T4000 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Removing a T4000 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . 224
Installing a T4000 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . 226
Replacing a T4000 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . 226
Removing a T4000 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . 226
Installing a T4000 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . 227
Replacing a T4000 LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Removing a T4000 LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Installing a T4000 LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Replacing a T4000 CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Removing a T4000 CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Installing a T4000 CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
Replacing a T4000 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Removing the T4000 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Installing the T4000 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Replacing a T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Removing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . 236
Installing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Copyright © 2013, Juniper Networks, Inc.
Table of Contents
Replacing a T4000 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Removing the T4000 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . 238
Installing the T4000 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Replacing a T4000 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Removing the T4000 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Installing the T4000 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Replacing a T4000 FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Removing a T4000 FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Installing a T4000 FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Replacing T4000 Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . 248
Taking the T4000 Host Subsystem Offline . . . . . . . . . . . . . . . . . . . . . . . . . 248
Replacing a Control Board or Routing Engine Component . . . . . . . . . . . . . . 252
Replacing a T4000 PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Removing a T4000 PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Installing a T4000 PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Replacing a T4000 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Removing a T4000 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . 258
Installing a T4000 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . 260
Replacing a T4000 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Removing a T4000 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . 262
Installing a T4000 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . 263
Replacing a T4000 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . . . . 264
Removing a T4000 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . 265
Installing a T4000 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . 265
Replacing a T4000 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . . . . 265
Removing a T4000 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . 265
Installing a T4000 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . 266
Replacing a T4000 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Removing a T4000 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Installing a T4000 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine . . . . . . 270
Preparing to Replace a CompactFlash Card in a T4000 RE-C1800 Routing
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Removing a CompactFlash Card from a T4000 RE-C1800 Routing
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
Installing a CompactFlash Card into a T4000 RE-C1800 Routing Engine . . 271
Copying Junos OS to the CompactFlash Card in a T1600 RE-C1800 Routing
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine . . . . . . . . . . 273
Preparing to Replace a Solid-State Disk from a T4000 RE-C1800 Routing
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Removing a Solid-State Disk from a T4000 RE-C1800 Routing Engine . . . 274
Installing a Solid-State Disk From a T4000 RE-C1800 Routing Engine . . . . 275
Copying Junos OS to the Solid-State Disk in a T4000 RE-C1800 Routing
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine . . . . . . . . . . . 276
Removing a DIMM Module from a T4000 RE-C1800 Routing Engine . . . . . 276
Installing a DIMM Module into a T4000 RE-C1800 Routing Engine . . . . . . . 276
Copyright © 2013, Juniper Networks, Inc.
ix
T4000 Router Hardware Guide
Part 5
Appendix A
Replacing a T4000 SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Removing a T4000 SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Installing a T4000 SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Replacing a T4000-SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Removing a T4000-SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Installing a T4000-SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Replacing a T4000 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Removing a T4000 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Installing a T4000 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Appendixes
Router Safety and Regulatory Compliance Information . . . . . . . . . . . . . . . 291
Definition of Safety Warning Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
General Safety Guidelines for Juniper Networks Devices . . . . . . . . . . . . . . . 293
General Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . 294
Qualified Personnel Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Restricted Access Area Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Preventing T4000 Electrostatic Discharge Damage . . . . . . . . . . . . . . . . . . 296
Fire Safety Requirements for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . 299
General Fire Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Fire Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Fire Suppression Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
T4000 Installation Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
General Installation Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Chassis Lifting Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Installation Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . 301
Installation Instructions Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
Rack-Mounting Requirements and Warnings . . . . . . . . . . . . . . . . . . . . . . . . 301
Ramp Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
Laser and LED Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 305
T4000 General Laser Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Laser Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . . 306
Class 1 Laser Product Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Class 1 LED Product Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Laser Beam Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Radiation from Open Port Apertures Warning . . . . . . . . . . . . . . . . . . . . 308
T4000 Maintenance and Operational Safety Guidelines and Warnings . . . . . . 309
Maintenance and Operational Safety Warnings for Juniper Networks
Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Battery Handling Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Jewelry Removal Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
Lightning Activity Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Operating Temperature Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
Product Disposal Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 x Copyright © 2013, Juniper Networks, Inc.
Table of Contents
Appendix B
Appendix C
Appendix D
T4000 Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . 314
T4000 General Electrical Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . 314
General Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . 315
Grounded Equipment Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Midplane Energy Hazard Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . 316
Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Site Electrical Wiring Guidelines for Juniper Networks Devices . . . . . . . . . . . 318
Distance Limitations for Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Radio Frequency Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Electromagnetic Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
DC Power Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . 319
T4000 DC Power Electrical Safety Guidelines . . . . . . . . . . . . . . . . . . . 320
DC Power Electrical Safety Warnings for Juniper Networks Devices . . . 321
Agency Approvals and Compliance Statements . . . . . . . . . . . . . . . . . . . . . . . . . 324
T4000 Agency Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
T4000 Compliance Statements for NEBS . . . . . . . . . . . . . . . . . . . . . . . . . . 326
T4000 Compliance Statements for EMC Requirements (European
Community) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
Compliance Statements for EMC Requirements for Juniper Networks Devices
(Canada) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
Compliance Statements for EMC Requirements for Juniper Networks Devices
(Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
Compliance Statements for EMC Requirements for Juniper Networks Devices
(United States) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
Compliance Statements for Environmental Requirements for Juniper
Networks Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
T4000 Compliance Statements for Acoustic Noise . . . . . . . . . . . . . . . . . . . 329
T4000 Router Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
T4000 Router Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
T4000 Router Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . 333
T4000 Router Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Power Guidelines, Requirements, and Specifications . . . . . . . . . . . . . . . . . 335
T4000 Chassis Grounding Cable and Lug Specifications . . . . . . . . . . . . . . . . . . 335
T4000 DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . 336
T4000 DC Power Supply Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
T4000 DC Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power
Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power
Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
T4000 DC Power Cable and Lugs Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 341
DC Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
DC Power Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
T4000 DC Power Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Copyright © 2013, Juniper Networks, Inc.
xi
T4000 Router Hardware Guide
Appendix E
Appendix F
Part 6
T4000 Router Cable and Wire Specifications, Pinouts, and Guidelines . . 345
T4000 Network Cable Specifications and Guidelines . . . . . . . . . . . . . . . . . . . . . 345
Network Cable and Transceiver Overview for T Series Routers . . . . . . . . . . 345
Ethernet Cables and Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
SONET/SDH Cables and Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . 346
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and
Dispersion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable . . . . . . . 347
Attenuation and Dispersion in Fiber-Optic Cable . . . . . . . . . . . . . . . . . . 347
Calculating Power Budget and Power Margin for Fiber-Optic Cables . . . . . 348
Calculating Power Budget for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . 348
Calculating Power Margin for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . 348
T4000 Routing Engine Interface Cable Specifications . . . . . . . . . . . . . . . . . . . . 350
T4000 Alarm Relay Contact Wire Specifications . . . . . . . . . . . . . . . . . . . . . . . . 350
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port . . . . . . . 351
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Contacting Customer Support and Returning Router Hardware . . . . . . . . 353
Contacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
Returning a Hardware Component to Juniper Networks, Inc. . . . . . . . . . . . . . . . 354
Tools and Parts Required to Remove Components from a T4000 Router . . . . . 355
Packing the T4000 Router for Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Packing the T4000 Router Components for Shipment . . . . . . . . . . . . . . . . . . . . 356
Displaying T4000 Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . 357
T4000 Component Serial Number Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
CIP Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
Control Board Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
Craft Interface Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
FPC Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
PIC Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
SCG Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
SIB Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Index
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367 xii Copyright © 2013, Juniper Networks, Inc.
List of Figures
Part 1
Chapter 1
Chapter 2
Chapter 3
Part 2
Chapter 5
T4000 Router Overview
T4000 Router Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 1: Front View of the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Figure 2: Rear View of the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
T4000 Router System Architecture Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 3: Router Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4: Control Packet Handling for Routing and Forwarding Table
Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 5: Data Flow Through the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
T4000 Hardware Components Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 6: Front View of Router Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 7: Rear View of Router Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 8: Midplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 9: Front Cable Management System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 10: Airflow Through the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 11: Front Panel of the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 12: LCD in Idle Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 13: LCD in Alarm Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 14: Front Panel of the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 15: CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 16: Enhanced Scaling T1600-FPC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 17: FPC5 Supported by the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 18: FPC Edges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 19: LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 20: LCC-CB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 21: RE-C1800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 22: RE-C1800 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 23: DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 24: T4000-SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 25: TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 26: TXP-3D-LCC SIB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 27: SCG with DB-9 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 28: SCG with RJ-48 ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 29: SCG with RJ-48 ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
T4000 Router Initial Installation
Preparing for T4000 Router Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 30: Typical Open-Frame Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Copyright © 2013, Juniper Networks, Inc.
xiii
T4000 Router Hardware Guide xiv
Chapter 6
Chapter 7
Chapter 9
Chapter 10
Chapter 11
Chapter 12
Figure 31: Chassis Dimensions and Clearance Requirements . . . . . . . . . . . . . . . . 60
Unpacking the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 32: Contents of the Shipping Crate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Installing the T4000 Router Mounting Hardware . . . . . . . . . . . . . . . . . . . . . 67
Figure 33: Installing the Mounting Hardware for a Four-Post Rack or Cabinet . . . 69
Figure 34: Positioning the Spacer Bar on the Rack . . . . . . . . . . . . . . . . . . . . . . . . . 70
Figure 35: Installing the Mounting Hardware for an Open-Frame Rack . . . . . . . . . 72
Figure 36: Removing the Center-Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . 73
Installing the T4000 Router Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . 77
Figure 37: Removing a DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 38: Attaching the Installation Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 39: Lifting the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 40: Installing the Router in a Four-Post Rack . . . . . . . . . . . . . . . . . . . . . . . 82
Figure 41: Reinstalling the Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Installing the T4000 Router Without a Mechanical Lift . . . . . . . . . . . . . . . . 85
Figure 42: Components to Remove from the Rear of the T4000 Router . . . . . . . 87
Figure 43: Components to Remove from the Front of the T4000 Router . . . . . . . 88
Figure 44: Removing a Six-Input DC Power Supply Before Installing the
Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 45: Removing a SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 46: Removing a Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 47: Removing the SCGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Figure 48: Removing the Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Figure 49: Removing an Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Figure 50: Removing a Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Figure 51: Removing an FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Figure 52: Attaching the Installation Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 53: Installing the Router in the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Figure 54: Reinstalling the Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Figure 55: Reinstalling an SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Figure 56: Reinstalling an LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Figure 57: Reinstalling a T4000 SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Figure 58: Reinstalling a Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . 106
Figure 59: Reinstalling an FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Figure 60: Reinstalling an Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Figure 61: Reinstalling a Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Grounding the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Figure 62: Grounding Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Figure 63: Connecting the Grounding Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Connecting the T4000 Router to External Devices . . . . . . . . . . . . . . . . . . . . 111
Figure 64: Console and Auxiliary Serial Port Connector . . . . . . . . . . . . . . . . . . . . . 113
Figure 65: Console and Auxiliary Ports on the CIP . . . . . . . . . . . . . . . . . . . . . . . . . 114
Figure 66: Attaching a Cable to a PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Figure 67: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . 118
Figure 68: ETHERNET Port on the CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Copyright © 2013, Juniper Networks, Inc.
List of Figures
Chapter 13
Part 4
Chapter 17
Chapter 19
Providing Power to the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Figure 69: Connecting DC Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Figure 70: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
INPUT 3, and INPUT 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Figure 71: Connecting Negative (–) DC Power Cables to INPUT 2 and
INPUT 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Figure 72: Connecting Positive (+) DC Power Cables to RTN 2, RTN 5, RTN 0,
RTN 1, RTN 3, and RTN 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Figure 73: Connecting DC Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Figure 74: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
INPUT 3, and INPUT 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Figure 75: Connecting Negative (–) DC Power Cable to INPUT 2 . . . . . . . . . . . . . 128
Figure 76: Connecting Positive (+) DC Power Cable to RTN 2, RTN 0, RTN 1,
RTN 3, RTN 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Figure 77: Connecting DC Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Figure 78: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1. INPUT
3, and INPUT 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Figure 79: Connecting Positive (+) DC Power Cables to RTN 0, RTN 1, RTN 3, and RTN 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Figure 80: Incorrect Cable Connection to INPUT 1 . . . . . . . . . . . . . . . . . . . . . . . . 134
Figure 81: Terminal Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Figure 82: Connecting DC Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Figure 83: Negative (–) DC Power Cables Connected to INPUT 1 and
INPUT 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Figure 84: Connecting Negative (–) DC Power Cable to INPUT 5 . . . . . . . . . . . . 138
Figure 85: Positive (+) DC Power Cables Connected to RTN 1, RTN 3, and RTN
5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Figure 86: Power Supply Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Figure 87: Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Maintenance, Troubleshooting, and Replacement Procedures
Maintaining T4000 Router Hardware Components . . . . . . . . . . . . . . . . . . . 179
Figure 88: Airflow Through the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Replacing T4000 Router Hardware Components . . . . . . . . . . . . . . . . . . . . 215
Figure 89: Removing the Front Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Figure 90: Replacing the Front Filter Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Figure 91: Installing the Front Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Figure 92: Removing the Rear Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Figure 93: Removing the Rear Air Filter Element . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Figure 94: Installing the Rear Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Figure 95: DB-9 Port on the CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Figure 96: Ethernet Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
Figure 97: Ethernet Port on CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
Figure 98: Removing an LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Figure 99: Installing an LCC-CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Figure 100: Removing the CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
Figure 101: Installing the CIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Copyright © 2013, Juniper Networks, Inc.
xv
T4000 Router Hardware Guide xvi
Part 5
Appendix A
Figure 102: Removing the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Figure 103: Installing a Replacement Craft Interface . . . . . . . . . . . . . . . . . . . . . . 236
Figure 104: Removing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . 237
Figure 105: Installing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . 238
Figure 106: Removing an Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Figure 107: Installing an Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Figure 108: Removing the FAN-R-TXP-3D-LCC Rear Fan Tray . . . . . . . . . . . . . . . 241
Figure 109: Installing the Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Figure 110: Removing an FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Figure 111: Installing an FPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Figure 112: Removing a PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Figure 113: Installing a PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Figure 114: DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
Figure 115: Disconnecting Power Cables from the DC Power Supply . . . . . . . . . . 258
Figure 116: Removing a DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Figure 117: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . . 260
Figure 118: Inserting the DC Power Supply into the Chassis . . . . . . . . . . . . . . . . . 260
Figure 119: Attaching the DC Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
Figure 120: Disconnecting the DC Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Figure 121: Connecting the DC Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Figure 122: Removing the Power Supply Side Air Filter . . . . . . . . . . . . . . . . . . . . . 266
Figure 123: Installing the Power Supply Side Air Filter . . . . . . . . . . . . . . . . . . . . . 266
Figure 124: Removing the Routing Engine Cover . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Figure 125: Removing a T4000 C1800 Routing Engine . . . . . . . . . . . . . . . . . . . . 268
Figure 126: Installing a Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Figure 127: Reinstalling the Routing Engine Cover . . . . . . . . . . . . . . . . . . . . . . . . 269
Figure 128: Removing a CompactFlash Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
Figure 129: Installing a CompactFlash Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Figure 130: Removing an SSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Figure 131: Installing an SSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Figure 132: Removing an SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Figure 133: Installing an SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Figure 134: Removing a T4000 SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Figure 135: Installing a T4000 SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Figure 136: CXP Cable and Dust Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Figure 137: CXP Transceiver and Dust Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Figure 138: AOC Transceiver and Dust Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Figure 139: Removing a TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Figure 140: Installing a TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Figure 141: Connecting a CXP Cable to a CXP Transceiver . . . . . . . . . . . . . . . . . . 287
Figure 142: Installing an AOC Transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Appendixes
Router Safety and Regulatory Compliance Information . . . . . . . . . . . . . . . 291
Figure 143: ESD Point on Front of the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
Figure 144: ESD Point on Rear of the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
Figure 145: Placing a Component into an Electrostatic Bag . . . . . . . . . . . . . . . . . 298
Figure 146: Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
Copyright © 2013, Juniper Networks, Inc.
List of Figures
Appendix D
Appendix F
Power Guidelines, Requirements, and Specifications . . . . . . . . . . . . . . . . . 335
Figure 147: Grounding Cable Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
Figure 148: DC Power Cable Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Figure 149: Typical DC Source Cabling to the Router . . . . . . . . . . . . . . . . . . . . . . 343
Contacting Customer Support and Returning Router Hardware . . . . . . . . 353
Figure 150: Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
Figure 151: CIP Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
Figure 152: LCC-CB Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
Figure 153: Craft Interface Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . 360
Figure 154: Serial Number Label on a T1600 Type 4 FPC . . . . . . . . . . . . . . . . . . 360
Figure 155: Type 5 FPC Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Figure 156: PIC Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
Figure 157: DC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . 362
Figure 158: Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Figure 159: SCG Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Figure 160: SIB Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
Copyright © 2013, Juniper Networks, Inc.
xvii
T4000 Router Hardware Guide xviii Copyright © 2013, Juniper Networks, Inc.
List of Tables
Part 1
Chapter 3
Part 2
Chapter 6
Chapter 7
About the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Table 1: Notice Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Table 2: Text and Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii
T4000 Router Overview
T4000 Hardware Components Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 3: T4000 Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 4: T4000 Supported Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 5: Alarm LEDs and Alarm Cutoff/Lamp Test Button . . . . . . . . . . . . . . . . . . 26
Table 6: FPC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 7: T4000 Host Subsystem LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 8: SIB LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 9: CIP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 10: Identifying the FPCs Supported by the Router . . . . . . . . . . . . . . . . . . . . . 31
Table 11: FPCs Supported by the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 12: T4000 Supported Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 13: LCC-CB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 14: T4000 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 15: Routing Engine C1800 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 16: Number of PICs Supported in Each FPC . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 17: Supported Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 18: Components Powered by Each Six-Input DC Power Supply Input . . . . . 44
Table 19: Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 20: T4000 Supported SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 21: T4000 and TXP-LCC-3D SIB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 22: TXP-LCC-3D SIB Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 23: Supported SCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Table 24: SCG LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
T4000 Router Initial Installation
Unpacking the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 25: Router Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 26: Accessory Box Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Installing the T4000 Router Mounting Hardware . . . . . . . . . . . . . . . . . . . . . 67
Table 27: Four-Post or Cabinet Rack Mounting Hole Locations . . . . . . . . . . . . . . . 67
Table 28: Open-Frame Rack Mounting Hole Locations . . . . . . . . . . . . . . . . . . . . . . 71
Copyright © 2013, Juniper Networks, Inc.
xix
T4000 Router Hardware Guide
Part 4
Chapter 18
Chapter 19
Part 5
Appendix B
Appendix C
Appendix D
Appendix E
Maintenance, Troubleshooting, and Replacement Procedures
Troubleshooting T4000 Router Hardware Components . . . . . . . . . . . . . . 189
Table 29: SONET/SDH Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . 192
Table 30: T4000 Cooling System Fan Tray Alarms . . . . . . . . . . . . . . . . . . . . . . . 193
Table 31: T4000 Temperature Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Table 32: Chassis Alarm Messages for the Craft Interface . . . . . . . . . . . . . . . . . . 196
Table 33: Chassis Alarm Messages for Host Subsystems . . . . . . . . . . . . . . . . . . . 197
Table 34: T4000 Chassis Alarm Messages for the Control Boards . . . . . . . . . . . 198
Table 35: Chassis Alarm Messages for the FPCs . . . . . . . . . . . . . . . . . . . . . . . . . 200
Table 36: Power System Chassis Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Table 37: Troubleshooting PDU LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Table 38: Chassis Alarm Messages for the SCGs . . . . . . . . . . . . . . . . . . . . . . . . . 209
Table 39: T4000 Chassis Alarm Messages for SIBs . . . . . . . . . . . . . . . . . . . . . . . 210
Replacing T4000 Router Hardware Components . . . . . . . . . . . . . . . . . . . . 215
Table 40: Field-Replaceable Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Table 41: Tools and Parts Required for Component Replacement . . . . . . . . . . . . 217
Table 42: Effect of Taking the Host Subsystem Offline . . . . . . . . . . . . . . . . . . . . 249
Appendixes
T4000 Router Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
Table 43: Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
T4000 Router Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . 333
Table 44: Router Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Power Guidelines, Requirements, and Specifications . . . . . . . . . . . . . . . . . 335
Table 45: Grounding Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
Table 46: DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . 336
Table 47: Power Supply Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 337
Table 48: Typical DC Power Requirements for T4000 Components . . . . . . . . . 338
Table 49: DC Power Cables Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
T4000 Router Cable and Wire Specifications, Pinouts, and Guidelines . . 345
Table 50: Ethernet Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
Table 51: SONET/SDH Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
Table 52: Estimated Values for Factors Causing Link Loss . . . . . . . . . . . . . . . . . . 349
Table 53: Cable Specifications for Routing Engine Management . . . . . . . . . . . . 350
Table 54: RJ-45 Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Table 55: DB-9 Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 xx Copyright © 2013, Juniper Networks, Inc.
About the Documentation
• Junos OS Documentation and Release Notes on page xxi
• Documentation Conventions on page xxi
• Documentation Feedback on page xxiii
• Requesting Technical Support on page xxiii
Junos OS Documentation and Release Notes
For a list of related Junos OS documentation, see http://www.juniper.net/techpubs/software/junos/ .
If the information in the latest release notes differs from the information in the documentation, follow the Junos OS Release Notes.
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at http://www.juniper.net/techpubs/ .
Documentation Conventions
Table 1 on page xxi defines the notice icons used in this guide.
Table 1: Notice Icons
Icon Meaning
Informational note
Description
Indicates important features or instructions.
Caution Indicates a situation that might result in loss of data or hardware damage.
Warning
Laser warning
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Copyright © 2013, Juniper Networks, Inc.
xxi
T4000 Router Hardware Guide
Table 2 on page xxii defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Italic text like this
Italic text like this
Text like this
< > (angle brackets)
| (pipe symbol)
Represents text that you type.
To enter configuration mode, type the configure command: user@host> configure
Represents output that appears on the terminal screen.
user@host> show chassis alarms
No alarms currently active
• Introduces or emphasizes important new terms.
•
•
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Enclose optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Enclose a variable for which you can substitute one or more values.
Identify a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions xxii Copyright © 2013, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions
(continued)
Convention Description
Bold text like this
> (bold right angle bracket)
Examples
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can send your comments to [email protected]
, or fill out the documentation feedback form at https://www.juniper.net/cgi-bin/docbugreport/ . If you are using e-mail, be sure to include the following information with your comments:
• Document or topic name
• URL or page number
• Software release version (if applicable)
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or JNASC support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit http://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: http://www.juniper.net/customers/support/
• Search for known bugs: http://www2.juniper.net/kb/
Copyright © 2013, Juniper Networks, Inc.
xxiii
T4000 Router Hardware Guide
• Find product documentation: http://www.juniper.net/techpubs/
• Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/
• Download the latest versions of software and review release notes: http://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: https://www.juniper.net/alerts/
• Join and participate in the Juniper Networks Community Forum: http://www.juniper.net/company/communities/
• Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
• Use the Case Management tool in the CSC at http://www.juniper.net/cm/ .
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see http://www.juniper.net/support/requesting-support.html
.
xxiv Copyright © 2013, Juniper Networks, Inc.
PART 1
T4000 Router Overview
• T4000 Router Overview on page 3
• T4000 Router System Architecture Overview on page 7
• T4000 Hardware Components Overview on page 13
Copyright © 2013, Juniper Networks, Inc.
1
T4000 Router Hardware Guide
2 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 1
T4000 Router Overview
• T4000 Router Description on page 3
T4000 Router Description
The Juniper Networks T4000 Core Router is a complete routing system that provides
Gigabit Ethernet, SONET/SDH, and other high-speed interfaces for large networks and network applications, such as those supported by Internet service providers (ISPs). The
T4000 router accommodates up to eight Flexible PIC Concentrators (FPCs), each of which can be configured with a variety of network media types. The router provides up to 2.0 terabits per second (Tbps), full duplex (4.0 Tbps of any-to-any, nonblocking, half-duplex) switching.
The router architecture cleanly separates control operations from packet forwarding operations. This design eliminates processing and traffic bottlenecks, permitting the router to achieve high performance.
• Control operations in the router are performed by the host subsystem, which runs the
Junos operating system (Junos OS) to handle routing protocols, traffic engineering, policy, policing, monitoring, and configuration management.
• Forwarding operations in the router are performed by the Packet Forwarding Engines, which consist of hardware, including ASICs, designed by Juniper Networks.
Application-specific integrated circuits (ASICs) are a definitive part of the router design; they enable the router to achieve data forwarding rates that match current fiber-optic capacity. The T4000 router provides up to a total of 2.4 billion packets per second
(Mpps) of forwarding.
Figure 1 on page 4 and Figure 2 on page 5 illustrate the front and rear of a T4000 router.
Copyright © 2013, Juniper Networks, Inc.
3
T4000 Router Hardware Guide
Figure 1: Front View of the T4000 Router
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
T Series
FANTRAY-T4000
ESD point
Air filter
Fan tray
Air intake
FANTRA
Y-T4000
4 Copyright © 2013, Juniper Networks, Inc.
Figure 2: Rear View of the T4000 Router
Fan tray
Air exhaust
SCGs
Control board 0
RE 0
RE 1
Control board 1
SIBs
Air filter
Power supply 0
Power supply 1
ESD point
Grounding points
Related
Documentation
• T4000 Chassis Description on page 15
• Overview of Installing the T4000 Router on page 55
Chapter 1: T4000 Router Overview
Copyright © 2013, Juniper Networks, Inc.
5
T4000 Router Hardware Guide
6 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 2
T4000 Router System Architecture
Overview
• System Architecture Description for T Series Routers on page 7
• Routing Engine Functions for T Series Routers on page 8
• Packet Forwarding Engine Architecture for T Series Routers on page 9
System Architecture Description for T Series Routers
The T Series Core Routers have two main architectural components:
• Routing Engine—One or more Routing Engines provide Layer 3 routing services and network management.
• Packet Forwarding Engines—These high-performance, ASIC-based components provide
Layer 2 and Layer 3 packet switching, route lookups, and packet forwarding.
The Routing Engines and the Packet Forwarding Engines perform their primary tasks independently, although they constantly communicate through multiple 100 millions of packets per second (Mbps) links. This arrangement streamlines forwarding and routing control and runs Internet-scale backbone networks at high speeds.
Figure 3 on page 7 shows the relationship between the Routing Engine and the Packet Forwarding Engines.
Figure 3: Router Architecture
Related
Documentation
• Routing Engine Functions for T Series Routers on page 8
• Packet Forwarding Engine Architecture for T Series Routers on page 9
Copyright © 2013, Juniper Networks, Inc.
7
T4000 Router Hardware Guide
Routing Engine Functions for T Series Routers
The Routing Engine handles all routing protocol processes, as well as the software processes that control the router's interfaces, the chassis components, system management, and user access to the router. The routing and software processes run on top of a kernel that interacts with the Packet Forwarding Engine.
The Routing Engine constructs and maintains one or more routing tables (see
Figure 4 on page 8 ). From the routing tables, the Routing Engine derives a table of active routes, called the forwarding table, which is then copied into the Packet Forwarding
Engine. The design of the ASICs allow the forwarding table in the Packet Forwarding
Engine to be updated without interrupting forwarding performance.
Figure 4: Control Packet Handling for Routing and Forwarding Table
Updates
8
The Routing Engine includes the following functions and features:
• Processing of routing protocol packets—The Routing Engine handles all packets that concern routing protocols, freeing the Packet Forwarding Engine to handle only packets that represent Internet traffic.
• Software modularity—Because each software process is devoted to a different function and uses a separate process space, the failure of one process has little or no effect on the others.
• In-depth Internet functionality—Each routing protocol is implemented with a complete set of Internet features and provides full flexibility for advertising, filtering, and modifying routes. Routing policies are set according to route parameters (for example, prefix, prefix lengths, and BGP attributes).
• Scalability—Junos OS routing tables have been designed to hold all the routes in current networks with ample capacity for expansion. Additionally, Junos OS can efficiently support large numbers of interfaces and virtual circuits.
• Management interface—Different levels of system management tools are provided, including the Junos OS command-line interface (CLI), the Junos XML management protocol, the craft interface, and SNMP.
Copyright © 2013, Juniper Networks, Inc.
Chapter 2: T4000 Router System Architecture Overview
• Storage and change management—Configuration files, system images, and microcode can be held and maintained in primary and secondary storage systems, permitting local or remote upgrades.
• Monitoring efficiency and flexibility—The router supports functions such as alarm handling and packet counting on every port, without degrading packet-forwarding performance.
Related
Documentation
• System Architecture Description for T Series Routers on page 7
• Packet Forwarding Engine Architecture for T Series Routers on page 9
Packet Forwarding Engine Architecture for T Series Routers
The Packet Forwarding Engines provide the Layer 2 and Layer 3 packet switching, forwarding, and route lookup functions. The Packet Forwarding Engines are implemented in ASICs that are physically located on the FPCs and the PICs. To ensure the efficient movement of data, the router is designed so that ASICs on the hardware components handle the forwarding of data.
• Packet Forwarding Engine Components on page 9
• Data Flow on page 9
Packet Forwarding Engine Components
Each Packet Forwarding Engine consists of the following components:
• Layer 2/Layer 3 Packet Processing ASIC, which performs Layer 2 and Layer 3 encapsulation and decapsulation, and manages the division and reassembly of packets within the router.
• Queuing and Memory Interface ASICs, which manage the buffering of data cells in memory and the queueing of notifications.
• T Series Internet Processor, which provides the route lookup function.
• Switch Interface ASICs, which extract the route lookup key and manage the flow of data cells across the switch fabric.
Media-specific ASICs on the PICs perform control functions tailored to the PIC media types.
Data Flow
To ensure the efficient movement of data, the router is designed so that ASICs on the hardware components handle the forwarding of data. Data flows through the router in the following sequence (see Figure 5 on page 10 ):
Copyright © 2013, Juniper Networks, Inc.
9
T4000 Router Hardware Guide
Figure 5: Data Flow Through the Router
10
1.
Packets arrive at an incoming PIC interface.
2.
The PIC passes the packets to the FPC, where the Layer 2/Layer 3 Packet Processing
ASIC performs Layer 2 and Layer 3 parsing and divides the packets into 64-byte cells.
3.
The Switch Interface ASIC extracts the route lookup key, places it in a notification, and passes the notification to the T Series Internet Processor. The Switch Interface
ASIC also passes the data cells to the Queuing and Memory Interface ASICs for buffering.
4.
The Queuing and Memory Interface ASICs pass the data cells to memory for buffering.
5.
The T Series Internet Processor performs the route lookup and forwards the notification to the Queuing and Memory Interface ASIC.
6.
The Queuing and Memory Interface ASIC sends the notification to the Switch Interface
ASIC facing the switch fabric, unless the destination is on the same Packet Forwarding
Engine. In this case, the notification is sent back to the Switch Interface ASIC facing the outgoing ports, and the packets are sent to the outgoing port without passing through the switch fabric (see Step 13 ).
7.
The Switch Interface ASIC sends bandwidth requests through the switch fabric to the destination port. The Switch Interface ASIC also issues read requests to the Queuing and Memory Interface ASIC to begin reading data cells out of memory.
8.
The destination Switch Interface ASIC sends bandwidth grants through the switch fabric to the originating Switch Interface ASIC.
Copyright © 2013, Juniper Networks, Inc.
Chapter 2: T4000 Router System Architecture Overview
9.
On receipt of each bandwidth grant, the originating Switch Interface ASIC sends a cell through the switch fabric to the destination Packet Forwarding Engine.
10.
The destination Switch Interface ASIC receives cells from the switch fabric. It extracts the route lookup key from each cell, places it in a notification, and forwards the notification to the T Series Internet Processor.
11.
The T Series Internet Processor performs the route lookup, and forwards the notification to the Queuing and Memory Interface ASIC.
12.
The Queuing and Memory Interface ASIC forwards the notification, including next-hop information, to the Switch Interface ASIC.
13.
The Switch Interface ASIC sends read requests to the Queuing and Memory Interface
ASIC to read the data cells out of memory, and passes the cells to the Layer 2/Layer
3 Packet Processing ASIC.
14.
The Layer 2/Layer 3 Packet Processing ASIC reassembles the data cells into packets, adds Layer 2 encapsulation, and sends the packets to the outgoing PIC interface.
15.
The outgoing PIC sends the packets out into the network.
Related
Documentation
• System Architecture Description for T Series Routers on page 7
• Routing Engine Functions for T Series Routers on page 8
Copyright © 2013, Juniper Networks, Inc.
11
T4000 Router Hardware Guide
12 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 3
T4000 Hardware Components Overview
• T4000 Hardware Component Overview on page 13
• T4000 Component Redundancy on page 15
• T4000 Chassis Description on page 15
• T4000 Midplane Description on page 18
• T4000 Cable Management System on page 20
• T4000 Cooling System Description on page 21
• T4000 Craft Interface Overview on page 23
• T4000 Connector Interface Panel (CIP) Overview on page 27
• T4000 FPC Overview on page 30
• T4000 Host Subsystem Overview on page 35
• T4000 PIC Description on page 42
• T4000 Power System Overview on page 43
• T4000 Switch Interface Board (SIB) Overview on page 45
• T4000 SONET Clock Generators (SCGs) Overview on page 49
T4000 Hardware Component Overview
The T4000 Core Router supports the components in Table 3 on page 13 , listed in alphabetic order.
Table 3: T4000 Hardware Components
Component Hardware Model Number CLI Name Description
Cable management system N/A N/A
Chassis N/A N/A
“T4000 Cable Management
System” on page 20
“T4000 Chassis Description” on page 15
Copyright © 2013, Juniper Networks, Inc.
13
T4000 Router Hardware Guide
Table 3: T4000 Hardware Components
(continued)
Component Hardware Model Number CLI Name
Cooling system, including fan trays and air filters
Front fan trays FANTRAY-T4000 Front Top Fan Tray
Front Bottom Fan Tray
Rear fan tray
Air filter kit
Control board
FAN-REAR-TXP-LCC
FAN-R-TXP-3D-LCC
FLTR-KIT-T640
CB-LCC
Rear Fan Tray
N/A
LCC Control Board
Description
“T4000 Cooling System
Description” on page 21
Craft interface
FPC
CRAFT-T-SERIES T4000 FPM Display
See “T4000 FPCs Supported” on page 34
“T4000 Control Board Description” on page 36
“T4000 Craft Interface Description” on page 23
“T4000 FPC Description” on page 30
Host subsystem
Midplane
See control board and Routing Engine.
N/A T-series Backplane
“T4000 Host Subsystem
Description” on page 35
“T4000 Midplane Description” on page 18
PIC
Power system
See the T4000 Interface
Module Reference .
See show chassis hardware “T4000 PIC Description” on page 42
PWR-T-6-60-DC Power Entry Module 6x60
Routing Engine
8G C1800 Routing Engine RE-DUO-C1800-8G RE-DUO-1800
RE-DUO-1800-16G
“T4000 Power System Description” on page 43
“T4000 Routing Engine
Description” on page 39
“T4000 RE-C1800 Routing Engine
Description” on page 40
16G C1800 Routing Engine RE-DUO-C1800-16G
SONET Clock Generator (SCG)
SCG with RJ-48 ports SCG-T-EC
“T4000 SONET Clock Generators
(SCGs) Description” on page 49
T640 Sonet Clock Gen.
T640 Sonet Clock Gen.
SCG with DB-9 ports
Switch Interface Board
(SIB)
SCG-T
SIB-I-T4000
SIB-TXP-3D-LCC
SIB-HC-3D “T4000 Switch Interface Board
(SIB) Description” on page 46
14 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
Related
Documentation
• T4000 Router Description on page 3
• T4000 Component Redundancy on page 15
T4000 Component Redundancy
The T4000 Core Router is designed so that no single point of failure can cause the entire system to fail. The following major hardware components are redundant:
• Switch Interface Boards (SIBs)—The router has five SIBs. For more information, see
“T4000 Switch Interface Board (SIB) Description” on page 46 .
• Host subsystem—The host subsystem consists of a Routing Engine functioning together with a control board. The router can have one or two host subsystems. If two host subsystems are installed, one functions as the master and the other functions as the backup. If the master host subsystem (or either of its components) fails, the backup can take over as the master. To operate, each host subsystem requires a Routing Engine installed in an adjacent slot to a control board. For more information, see “T4000
RE-C1800 Routing Engine Description” on page 40 , “T4000 LCC-CB” on page 37 , and
“T4000 Host Subsystem Description” on page 35 .
If the Routing Engines are configured for nonstop active routing, the backup Routing
Engine automatically synchronizes its configuration and state with the master Routing
Engine. Any update to the master Routing Engine state is replicated on the backup
Routing Engine. If the backup Routing Engine assumes mastership, packet forwarding continues through the router without interruption. For more information about nonstop active routing, see the Junos OS High Availability Library for Routing Devices .
• SONET Clock Generators (SCGs)—The router has a standard configuration of one
SCG. A second can be purchased to function as backup. If one SCG fails, the other becomes the master SCG. Mastership of the SCGs is independent of the host subsystem, so routing functions are not affected. For more information, see “T4000 SONET Clock
Generators (SCGs) Description” on page 49 .
• Power supplies—The router has two power supplies, which share the load evenly. If one power supply fails, the other power supply can provide full power to the router indefinitely. For more information, see “T4000 Power System Description” on page 43 .
• Cooling system—The cooling system has redundant components, which are controlled by the host subsystem. If one of the fans fails, the host subsystem increases the speed of the remaining fans to provide sufficient cooling for the router indefinitely. For more information, see “T4000 Cooling System Description” on page 21 .
Related
Documentation
• T4000 Router Description on page 3
T4000 Chassis Description
The T4000 Core Router chassis is a rigid sheet metal structure that houses all the other router components (see Figure 6 on page 17 and Figure 7 on page 18 ). The chassis
Copyright © 2013, Juniper Networks, Inc.
15
T4000 Router Hardware Guide measures 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide. The chassis can be installed into many types of racks or cabinets.
The chassis includes the following features (see Figure 6 on page 17 and
Figure 7 on page 18 ):
• Front-mounting flanges for mounting in a four-post rack or cabinet or front-mounting in an open-frame rack.
• Center-mounting metal brackets for center-mounting in an open-frame rack.
• Handles on each side to facilitate positioning the router in the rack. Do not use the handles to lift the router.
• Two electrostatic discharge (ESD) points (banana plug receptacles), one front and one rear.
CAUTION: Before removing or installing components of a router, attach an ESD strap to an ESD point, and place the other end of the strap around your bare wrist. Failure to use an ESD strap could result in damage to the router.
WARNING: The router must be connected to earth ground during normal operation.
16 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
Figure 6: Front View of Router Chassis
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
T Series
FANTRAY-T4000
ESD point
Air filter
Fan tray
Air intake
FANTRA
Y-T4000
Copyright © 2013, Juniper Networks, Inc.
17
T4000 Router Hardware Guide
Figure 7: Rear View of Router Chassis
Fan tray
Air exhaust
SCGs
Control board 0
RE 0
RE 1
Control board 1
SIBs
Air filter
Power supply 0
Power supply 1
ESD point
Grounding points
Related
Documentation
• T4000 Router Description on page 3
• T4000 Router Physical Specifications on page 331
• T4000 Component Serial Number Locations on page 358
T4000 Midplane Description
The midplane is located in the center of the chassis and forms the rear of the FPC card cage (see Figure 8 on page 19 ). The FPCs install into the midplane from the front of the chassis, and the SIBs, Routing Engines, and control boards and SCGs install into the midplane from the rear of the chassis. The power supplies and cooling system components also connect to the midplane.
The midplane performs the following major functions:
18 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
• Data path—Data packets are transferred across the midplane from the Packet
Forwarding Engine on the originating FPC to the SIBs, and from the SIBs across the midplane to the Packet Forwarding Engine on the destination FPC.
• Power distribution—The router power supplies are connected to the midplane, which distributes power to all the router components.
• Signal path—The midplane provides the signal path to the FPCs, SIBs, Routing Engines,
CB, and other system components for monitoring and control of the system.
Figure 8: Midplane
Midplane
FPC card cage
Related
Documentation
• T4000 Router Description on page 3
• T4000 Chassis Description on page 15
• T4000 Component Redundancy on page 15
Copyright © 2013, Juniper Networks, Inc.
19
T4000 Router Hardware Guide
T4000 Cable Management System
The front cable management system (see Figure 9 on page 20 ) consists of a row of nine semicircular plastic bobbins mounted on the front of the router below the FPC card cage.
The PIC cables pass between the bobbins and into the tray, keeping the cables organized and securely in place. The curvature of the bobbins also helps maintain the proper bend radius for optical PIC cables.
You can pull the front cable management system up and outward to lock it into the maintenance position. This allows you to access the lower fan tray and the front air filter.
Figure 9: Front Cable Management System
20
For T4000 routers connected to a TX Matrix Plus router, you can use the optional rear cable management system (model number CBL-MGR-TXP-3D-LCC) to organize, support, and provide strain relief for the cables connected to the TXP-LCC-3D SIBs and the cables connected to the LCC-CBs. The rear cable management system consists of one cable management arm. The cables are routed to the left side of the T4000 router, and then toward the top of the chassis, where you can route the cables to the TX Matrix Plus router.
The cable management system adds 9.5 in. (24.1 cm) to the depth of the T4000 chassis, and 2.4 in. (6.2 cm) to the left side of the chassis.
The LCC rear cable management system can be used for any configuration including,
TXP-T1600 configuration, TXP-T1600-3D configuration, TXP-T4000-3D configuration, and TXP-Mixed-LCC-3D configuration.
See the TX Matrix Plus Router Hardware Guide for instructions on installing and using the
T4000 rear cable management system.
Related
Documentation
• T4000 Chassis Description on page 15
• T4000 FPC Description on page 30
• T4000 PIC Description on page 42
Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
T4000 Cooling System Description
The cooling system components work together to keep all router components within the acceptable temperature range. The host subsystem monitors the temperature of the router components. When the router is operating normally, the fans function at normal speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is set to full speed. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down some or all of the hardware components.
In additions to the fans, the front fan trays are equipped with a fan tray controller (FTC) board. The FTC board is a transition board that distributes the fan-related signals between the Routing Engine and the fans, and controls the speed as required.
• Airflow on page 21
• Fan Trays on page 22
• Air Filters on page 22
• Power Supply Cooling System on page 22
Airflow
Figure 10 on page 21 shows the airflow through the router.
Figure 10: Airflow Through the Chassis
Copyright © 2013, Juniper Networks, Inc.
21
T4000 Router Hardware Guide
Fan Trays
The cooling system contains the following fan trays:
• One upper front fan tray and one lower front fan tray that cool the components installed in the front card cage (the FPCs, PICs, CIP, and the midplane).
• Rear fan tray containing eight fans.
NOTE: FAN-R-TXP-3D-LCC contains sixteen fans.
The upper and lower front fan trays contain six fans. Both fan trays are interchangeable with each other.
One rear fan tray cools the components installed in the rear card cage (the Routing
Engines, control boards, SCGs, and the SIBs). The rear fan tray is not interchangeable with the front fan trays.
All fan trays are hot-insertable and hot-removable.
CAUTION: To maintain proper cooling, do not operate the routing node with the rear fan tray removed for more than one minute.
The T4000 router supports the fan trays listed in Table 4 on page 22 .
Table 4: T4000 Supported Fan Trays
Name Model Number
First Supported Junos OS
Release
Front Upper Fan Tray
Front Lower Fan Tray
FANTRAY-T4000
FANTRAY-T4000
12.1
12.1
Rear Fan Tray
Rear Fan Tray
FAN-REAR-TXP-LCC
FAN-R-TXP-3D-LCC
12.1
13.1
Air Filters
The cooling system contains a front air filter and a rear air filter. All air filters are hot-insertable and hot-removable.
Power Supply Cooling System
Each DC power supply contains two blowers that cool that power supply.
Related
Documentation
• T4000 Router Description on page 3
22 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
• Maintaining the T4000 Fan Trays on page 181
• Troubleshooting the T4000 Cooling System on page 193
• T4000 Router Environmental Specifications on page 333
T4000 Craft Interface Overview
• T4000 Craft Interface Description on page 23
• T4000 Craft Interface LEDs on page 25
T4000 Craft Interface Description
The craft interface allows you to view status and troubleshooting information at a glance and to perform many system control functions. It is hot-insertable and hot-removable.
The craft interface is located on the front of the T4000 Core Router above the FPCs (see
Figure 11 on page 23 ).
Figure 11: Front Panel of the Craft Interface
Red alarm
LED
Yellow alarm
LED
LCD display
Host subsystem
LEDs
SIB
LEDs
FAIL
FPC 0
OK
ACO/LT
FAIL
FPC 1
OK
MENU
ENTER
FAIL
FPC 2
OK FAIL
FPC 3
OK FAIL
FPC 4
OK FAIL
FPC 5
OK
FAIL
FAIL
OK MASTER
HOST0
OK MASTER
HOST1
FAIL
FPC 6
OK
SP0
SP1
SP2
SP3
SP4
FAIL OK
FAIL
FPC 7
OK
FPC LEDs and online/offline buttons
• Craft Interface Front Panel on page 23
• Craft Interface LCD on page 24
Craft Interface Front Panel
The front panel of the craft interface contains:
• A four-line LCD display, along with six navigation buttons. The LCD display operates in Idle mode or alarm mode.
• ONLINE/OFFLINE button for each FPC that you use to take the FPC offline and bring it online. The button is located next to the FPC LEDs on the bottom of the craft interface.
• LEDs
• Yellow Minor Alarm LED, Red Major Critical Alarm LED, and alarm cutoff/lamp test
ACO/LT button
• Host subsystem Master , OK , and FAIL LEDs
• SIB OK and FAIL LEDs
• FPC OK and FAIL LEDs for the fans
Copyright © 2013, Juniper Networks, Inc.
23
T4000 Router Hardware Guide
Craft Interface LCD
A four-line LCD is located in the craft interface, along with six navigation buttons. The
LCD operates in two modes:
• LED idle mode
• LED alarm mode
During normal operation, the LCD operates in idle mode and reports current status information, as shown in Figure 12 on page 24 .
Figure 12: LCD in Idle Mode
The lines in the display report the following information:
• First line—Router name.
• Second line—Length of time the router has been running, reported in the following form:
Up days + hours:minutes
• Third and fourth lines—Status messages, which rotate at 2-second intervals. Some conditions, such as removal or insertion of a system component, can interrupt the messages.
To add a message that alternates every 2 seconds with the default status messages, use the set chassis display message command.
When a red or yellow alarm occurs, the LCD switches to alarm mode and reports the alarm condition, as shown in Figure 13 on page 24 .
Figure 13: LCD in Alarm Mode
24
The lines in the display report the following information:
• First line—Router name.
• Second line—Number of active alarms.
Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
• Third and fourth lines—Individual alarm messages, with the most severe condition shown first. The prefix on each line indicates whether the alarm is a red ( R ) or yellow ( Y ) alarm.
Related
Documentation
• T4000 Craft Interface LEDs on page 25
• T4000 Alarm Messages Overview on page 191
• Chassis Operational Mode Commands
T4000 Craft Interface LEDs
Figure 14 on page 25 shows the LEDs on the craft interface.
Figure 14: Front Panel of the Craft Interface
Red alarm
LED
Yellow alarm
LED
LCD display
Host subsystem
LEDs
SIB
LEDs
FAIL
FPC 0
OK
ACO/LT
FAIL
FPC 1
OK
MENU
ENTER
FAIL
FPC 2
OK FAIL
FPC 3
OK FAIL
FPC 4
OK FAIL
FPC 5
OK
FAIL
FAIL
OK MASTER
HOST0
OK MASTER
HOST1
FAIL
FPC 6
OK
SP0
SP1
SP2
SP3
SP4
FAIL OK
FAIL
FPC 7
OK
FPC LEDs and online/offline buttons
• Alarm LEDs on page 25
• FPC LEDs on page 26
• Host Subsystem LEDs on page 26
• SIB LEDs on page 27
Alarm LEDs
Two large alarm LEDs are located at the upper left of the craft interface. The circular red
LED lights to indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously.
A condition that causes an LED to light also activates the corresponding alarm relay contact on the Connector Interface Panel (CIP). The LCD on the craft interface reports the cause of the alarm.
To deactivate red and yellow alarms, press the button labeled ACO/LT (for “alarm cutoff/lamp test”), which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates the device attached to the corresponding alarm relay contact on the CIP. However, the LCD continues to report the alarm message until you clear the condition that caused the alarm.
Table 5 on page 26 describes the alarm LEDs and alarm cutoff button in more detail.
Copyright © 2013, Juniper Networks, Inc.
25
T4000 Router Hardware Guide
26
Table 5: Alarm LEDs and Alarm Cutoff/Lamp Test Button
Shape Color State Description
Red
Yellow
—
On steadily Critical alarm LED—Indicates a critical condition that can cause the router to stop functioning. Possible causes include component removal, failure, or overheating.
On steadily Warning alarm LED—Indicates a serious but nonfatal error condition, such as a maintenance alert or a significant increase in component temperature.
— Alarm cutoff/lamp test button—Deactivates red and yellow alarms. Causes all LEDs on the craft interface to light (for testing purposes), when pressed and held.
FPC LEDs
Each FPC slot has two LEDs that indicate its status. The FPC LEDs, labeled FPC0 through
FPC7 , are located along the bottom of the craft interface.
Table 6 on page 26 describes the functions of the FPC LEDs.
Table 6: FPC LEDs
Label Color State Description
Red On steadily FPC has failed.
FAIL
OK Green On steadily FPC is functioning normally.
Blinking FPC is starting up.
Host Subsystem LEDs
Each host subsystem has three LEDs, located on the upper right of the craft interface, that indicate its status. The LEDs labeled HOST0 show the status of the Routing Engine in slot RE0 and the CB in slot CB0 . The LEDs labeled HOST1 show the status of the Routing
Engine in slot RE1 and the CB in slot CB1 .
Table 7 on page 26 describes the functions of the host subsystem LEDs.
Table 7: T4000 Host Subsystem LEDs
Label Color State Description
FAIL Red
Green
On steadily Host is offline.
On steadily Host is online and is functioning normally.
OK
MASTER Green On steadily Host is functioning as the master.
Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
SIB LEDs
Each SIB has two LEDs on the craft interface that indicate its status. The SIB LEDs, labeled
SIB0 through SIB4 , are located on the upper right of the craft interface. The ACTIVE LED on the SIB faceplate is not replicated on the craft interface.
Table 8 on page 27 describes the functions of the SIB LEDs.
Table 8: SIB LEDs on the Craft Interface
Label Color State Description
FAIL
OK
Red
Green
On steadily SIB has failed.
On steadily SIB is functioning normally.
Related
Documentation
• T4000 Craft Interface Description on page 23
• T4000 LED Overview on page 190
• T4000 Alarm Messages Overview on page 191
T4000 Connector Interface Panel (CIP) Overview
• T4000 Connector Interface Panel (CIP) Description on page 27
• T4000 Connector Interface Panel (CIP) LEDs on page 29
T4000 Connector Interface Panel (CIP) Description
• T4000 Connector Interface Panel (CIP) Components on page 27
• Management Ports on page 28
• T4000 Alarm Relay Contacts on page 29
T4000 Connector Interface Panel (CIP) Components
The Connector Interface Panel (CIP) consists of Ethernet, console, and auxiliary ports for the Routing Engines and alarm relay contacts (see Figure 15 on page 28 ). The CIP is located at the left side of the FPC card cage, above the front electrostatic discharge point.
The CIP is hot-pluggable.
Copyright © 2013, Juniper Networks, Inc.
27
T4000 Router Hardware Guide
Figure 15: CIP
28
Management Ports
The CIP has two sets of management ports (see Figure 15 on page 28 ) that you use to connect the Routing Engines to external management devices. The upper set of ports, labeled HOST 0 , connects to the Routing Engine in slot RE0 ; and the lower set, labeled
HOST 1 , connects to the Routing Engine in slot RE1 . From these management devices, you can use the CLI to configure the router.
Each set includes the following ports:
• ETHERNET —Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support
Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview both 10- and 100-Mbps connections. Two small LEDs on the left edge of the port indicate the connection in use: the yellow LED lights for a 10-Mbps connection, and the green LED lights for a 100-Mbps connection.
• CONSOLE —Connects the Routing Engine to a system console through an RS-232
(EIA-232) serial cable.
• AUXILIARY — Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable.
T4000 Alarm Relay Contacts
The CIP has two alarm relay contacts for connecting the router to external alarm devices
(see Figure 15 on page 28 ). Whenever a system condition triggers either the red or yellow alarm on the craft interface, the alarm relay contacts are also activated. The alarm relay contacts are located below the Routing Engine ports. The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
Related
Documentation
• Overview of Connecting the T4000 Router to External Devices on page 111
• Tools and Parts Required to Connect the T4000 Router to External Devices on page 112
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
• Connecting the T4000 Router to an External Alarm-Reporting Device on page 114
• Connecting the T4000 Router to a Management Ethernet Device on page 118
T4000 Connector Interface Panel (CIP) LEDs
Two small LEDs on the left edge of the ETHERNET port indicate activity and the speed of the connection in use.
Table 9 on page 29 describes the functions of the LEDs.
NOTE: For routers with RE-C1800 Routing Engines, see the release notes for your router regarding more information about the LED behavior for the
ETHERNET port.
Table 9: CIP LEDs
LED Color
ACT 0 and ACT 1 Green
--
State
On steadliy
Off
Description
Traffic is passing through the port.
No traffic is passing through the port.
Copyright © 2013, Juniper Networks, Inc.
29
T4000 Router Hardware Guide
Table 9: CIP LEDs
(continued)
LED Color
GRN = 100M
YEL= 10M
Green
Yellow
--
State
On steadily
On steadily
Off
Description
100-Mbps connection
10-Mbps connection
NOTE: When RE-C1800 Routing Engines are installed, the yellow LED indicates a 100-Mbps connection.
Control board is offline.
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
T4000 FPC Overview
• T4000 FPC Description on page 30
• T4000 FPCs Supported on page 34
T4000 FPC Description
FPCs are hot-removable and hot-insertable.
• T4000 FPC Slots on page 30
• T4000 FPC Function on page 30
• T4000 FPC Components on page 31
• Identifying the FPCs on page 31
• FPC Terminology on page 33
T4000 FPC Slots
Up to eight FPCs install vertically in the front of the router. The FPC slots are numbered
FPC0 through FPC7 , left to right. If a slot is not occupied by an FPC, an FPC blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
T4000 FPC Function
FPCs house the PICs that connect the T4000 Core Router to network media. The main function of an FPC is to connect the PICs installed in it to the other T4000 router components. The Packet Forwarding Engine receives incoming packets from the PICs installed on the FPC and forwards them through the switch planes to the appropriate destination port. In a maximum configuration with eight Type 5 FPCs installed, the Packet
Forwarding Engines can forward up to 4000 million packets per second (Mpps) for all packet sizes. The T4000 Core Router provides up to 2000 gigabits per second (Gbps), full duplex switching (4000 Gbps of any-to-any, nonblocking, half-duplex switching).
30 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
When you install an FPC into a functioning router, the Routing Engine downloads the
FPC software, the FPC runs its diagnostics, and the PICs housed on the FPC are enabled.
Forwarding on other FPCs continues uninterrupted during this process.
T4000 FPC Components
Each FPC consists of the following components:
• FPC card carrier
• One or two Packet Forwarding Engines
• Each T1600-FPC4-ES has two Packet Forwarding Engines. Each Packet Forwarding
Engine consists of Layer 2/Layer 3 Packet Processing ASICs, Switch Interface ASICs,
T Series Internet Processor ASICs, and a Memory Mezzanine Board (MMB) which includes the Queuing and Memory Interface ASICs.
• Each T4000-FPC5-3D or T4000-FPC5-LSR has two Packet Forwarding Engines.
Each Packet Forwarding Engine consists of a Packet Processing ASIC, Interface ASIC, and Switch Interface ASIC.
• Processor Mezzanine Board (PMB), which includes a 1.2-GHz CPU, system controller,
4 GB of DDR3 RAM, and two 10/100/1000Mbps three-speed Ethernet interfaces
• Two LEDs— OK and FAIL —located on the craft interface above the FPC, that display the status of the FPC
• FPC online/offline button, located on the craft interface above the FPC
Identifying the FPCs
Check the label on the faceplate to identify the FPC. See Table 10 on page 31 .
Table 10: Identifying the FPCs Supported by the Router
FPC Label on the FPC Faceplate
T1600 Enhanced Scaling FPC4
T4000 FPC5
T1600-FPC4
•
•
T4000-FPC5-3D
T4000-FPC5-LSR
Copyright © 2013, Juniper Networks, Inc.
31
T4000 Router Hardware Guide
The enhanced scaling T1600-FPC4 is shown in Figure 16 on page 32 .
Figure 16: Enhanced Scaling T1600-FPC4
32 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
The T4000 FPC5 (T4000-FPC5-3D and T4000-FPC5-LSR) is shown in
Figure 17 on page 33 .
Figure 17: FPC5 Supported by the Router
12V
300W
FPC Terminology
Regardless of whether you are holding an FPC vertically or horizontally, this document uses the same terms for all four edges of the FPC (see Figure 18 on page 34 ):
• Faceplate—Edge of the FPC that has slots into which you insert the PICs
• Connector edge—Edge opposite the faceplate; this edge has the connectors that attach to the midplane
• Top edge—Edge at the top of the FPC when it is vertical
• Bottom edge—Edge at the bottom of the FPC when it is vertical
Copyright © 2013, Juniper Networks, Inc.
33
T4000 Router Hardware Guide
Figure 18: FPC Edges
Related
Documentation
• T4000 FPCs Supported on page 34
• T4000 Craft Interface LEDs on page 25
• Maintaining T4000 FPCs on page 184
• Troubleshooting the T4000 FPCs on page 200
T4000 FPCs Supported
T4000 Core Routers support the FPCs listed in Table 11 on page 34 . You can install any combination of the following FPCs. The First Junos OS Release Supported column indicates the first release that the FPC is supported in the T4000 router.
Table 11: FPCs Supported by the T4000 Router
FPC
Type FPC Name
FPC Model
Number CLI Name
Maximum
Number of PICs
Maximum
Throughput per
FPC
First Junos OS
Release
Supported
1 FPC Type 1-ES 4 4 Gbps 12.1R2
2
3
4
Enhanced
Scaling FPC1
Enhanced
Scaling FPC2
T640-FPC1-E2
T640-FPC2-ES
Enhanced
Scaling FPC3
T640-FPC3-ES
T1600
Enhanced
Scaling FPC4
T1600-FPC4-ES
FPC Type 2-ES
FPC Type 3-ES
FPC Type 4-ES
4
4
2
16 Gbps
40 Gbps
100 Gbps
12.2
12.1R2
12.1
34 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
Table 11: FPCs Supported by the T4000 Router
(continued)
FPC
Type FPC Name
FPC Model
Number CLI Name
Maximum
Number of PICs
Maximum
Throughput per
FPC
First Junos OS
Release
Supported
5
Enhanced
Scaling
FPC4-1P
T4000 FPC5
T640-FPC4-1P-ES FPC Type 4.1-ES
NOTE: T640-FPC4-ES is not supported.
1
T4000-FPC5-3D FPC Type 5-3D 2
T4000-FPC5-LSR FPC Type 5 -LSR 2
100 Gbps
240 Gbps
240 Gbps
12.1R2
12.1
12.3R2
13.1
Related
Documentation
• T4000 FPC Description
• T4000 PIC/FPC Compatibility
• T4000 Interface Module Reference
T4000 Host Subsystem Overview
• T4000 Host Subsystem Description on page 35
• T4000 Control Board Overview on page 36
• T4000 Routing Engine Overview on page 39
T4000 Host Subsystem Description
The host subsystem provides the routing and system management functions of the router. The host subsystem consists of a Routing Engine and an adjacent control board.
To operate, each host subsystem functions as a unit; the Routing Engine requires the corresponding control board, and vice versa.
NOTE: You can install one or two host subsystems on the router. We recommend that you install two host subsystems for redundant protection.
If you install only one host subsystem, we recommend that you install it in slots RE0 and CB0 .
Each host subsystem has three LEDs, located on the upper right of the craft interface, that display its status. In addition, there are LEDs on each Routing Engine and control board.
Related
Documentation
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 LCC-CB on page 37
Copyright © 2013, Juniper Networks, Inc.
35
T4000 Router Hardware Guide
• T4000 Craft Interface LEDs on page 25
• T4000 RE-C1800 LEDs on page 41
• T4000 LCC-CB Control Board LEDs on page 37
T4000 Control Board Overview
• T4000 Control Board Description on page 36
• T4000 LCC-CB on page 37
• T4000 LCC-CB Control Board LEDs on page 37
T4000 Control Board Description
The T4000 chassis supports up to two control boards. The Routing Engine requires an adjacent control board to provide control and monitoring functions for the router. These functions include determining Routing Engine mastership, controlling power and reset for the other router components, monitoring and controlling fan speed, and monitoring system status.
You can install up to two control boards in the chassis. Control boards install into the upper rear of the chassis in the slots labeled CB0 and CB1 (referred to as CB-0 and CB-1 , top to bottom). If two control boards are installed, one functions as the master and the other as its backup. If the master fails or is removed, the backup restarts and becomes the master.
Each control board requires a Routing Engine to be installed in the adjacent slot.
CB0 installs above RE0 , and CB1 installs below RE1 . Control boards cannot function if a Routing
Engine is not present in the adjacent slot.
If the host system is redundant, the backup control board is hot-removable and hot-insertable, but the master control board is hot-pluggable. A control board that is not redundant is hot-pluggable.
The T4000 router supports the control board listed in Table 12 on page 36
Table 12: T4000 Supported Control Board
Name Model Number
First Supported Junos OS
Release
Line-card chassis control board
(LCC-CB)
CB-LCC 12.1
Related
Documentation
• T4000 LCC-CB on page 37
• T4000 Craft Interface LEDs on page 25
• T4000 LCC-CB Control Board LEDs on page 37
36 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
T4000 LCC-CB
Each LCC-CB consists of the following components:
• 100-MB Ethernet switch for intermodule communication.
• PCI bus to the Routing Engines.
• Switch processor mezzanine board (SPMB).
Figure 19: LCC-CB
The following components are located on the LCC-CB faceplate:
• Two configuration switches:
• The M/S configuration switch must be set to S .
• The CHASSIS ID configuration switch must be set to 0 .
• Three LEDs labeled MASTER , FAIL , and OK , which indicate the control board status.
• The online/offline button.
• Six RJ-45 ports labeled SFC0 through SFC5 , which is currently not supported. The two
LEDs for each port labeled LINK and ACT are also not currently supported.
• One JCS port, which is not currently supported. The LINK LED for this port is also not currently supported.
Related
Documentation
• T4000 Control Board Description on page 36
• T4000 Craft Interface LEDs on page 25
• T4000 LCC-CB Control Board LEDs on page 37
T4000 LCC-CB Control Board LEDs
Status LEDs and port LEDs are located on the faceplate of the LCC-CB (see
Figure 20 on page 38 ).
Copyright © 2013, Juniper Networks, Inc.
37
T4000 Router Hardware Guide
Figure 20: LCC-CB LEDs
Link
LED
Activity
LED
38
• LCC-CB LEDs on page 38
• LCC-CB Port LEDs on page 38
LCC-CB LEDs
The LEDs located in the middle of the LCC-CB indicate its status.
Table 13 on page 38 describes the functions of the LCC-CB LEDs.
Table 13: LCC-CB LEDs
Label Color State Description
MASTER
FAIL
Blue
–
Yellow
On steadily LCC-CB is functioning as the master.
Off LCC-CB is functioning as the backup.
On steadily LCC-CB has failed.
OK
–
Green
–
Off No faults have been detected on the LCC-CB.
On steadily LCC-CB is online and is functioning normally.
Blinking
Off
LCC-CB is powering up, but not online.
LCC-CB is offline.
LCC-CB Port LEDs
The six RJ-45 ports labeled SFC0 through SFC4 , the port labeled JCS , and the LEDs for each port labeled LINK or ACT are not currently supported.
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Control Board Description on page 36
• T4000 Craft Interface LEDs on page 25
Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
T4000 Routing Engine Overview
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
T4000 Routing Engine Description
The Routing Engine runs Junos OS. The software processes that run on the Routing Engine maintain the routing tables, manage the routing protocols used on the router, control the router interfaces and some chassis components, and provide the interface for system management and user access to the router.
You can install one or two Routing Engines in the router. The Routing Engines install into the upper rear of the chassis in the slots labeled RE0 and RE1 . Each Routing Engine requires a control board to be installed in the adjacent slot.
RE0 installs below CB0 , and RE1 installs above CB1 . A Routing Engine does not power up without a control board present in the adjacent slot.
If two Routing Engines are installed, one functions as the master and the other acts as the backup. If the master Routing Engine fails or is removed and the backup is configured appropriately, the backup takes over as the master. If the host system is redundant, the backup Routing Engine is hot-removable and hot-insertable, but the master Routing
Engine is hot-pluggable. A Routing Engine that is not redundant requires that you power down the router before replacement.
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show chassis routing-engine command.
The ports for connecting the Routing Engine to external management devices are located on the Connector Interface Panel (CIP).
The T4000 router supports the Routing Engine in Table 14 on page 39 .
Table 14: T4000 Supported Routing Engines
Name Model Number
First Supported Junos OS
Release
RE-C1800
RE-C1800
RE-DUO-C1800-8G
RE-DUO-C1800-8G
12.1
12.1R2
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Control Board Description on page 36
• T4000 Craft Interface LEDs on page 25
Copyright © 2013, Juniper Networks, Inc.
39
T4000 Router Hardware Guide
• T4000 Connector Interface Panel (CIP) Description on page 27
T4000 RE-C1800 Routing Engine Description
• RE-C1800 Routing Engine Components on page 40
• RE-C1800 Boot Order on page 41
RE-C1800 Routing Engine Components
Each RE-C1800 Routing Engine ( Figure 21 on page 40 ) consists of the following components:
• CPU—Runs Junos OS to maintain the routing tables and routing protocols.
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• EEPROM—Stores the serial number of the Routing Engine.
• Interfaces for management access—Provide information about Routing Engine status to devices (console, laptop, or terminal server) connected to the management ports located on the CIP.
Figure 21: RE-C1800
The faceplate of the RE-C1800 contains the following:
• USB port—Provides a removable media interface through which you can install Junos
OS manually. Junos OS supports USB version 1.1 and version 2.0 devices.
• CompactFlash card slot—Provides primary storage for software images, configuration files, and microcode.
• Two solid-state disk (SSD) slots—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
NOTE: DISK2 is not currently supported.
• Reset button—Reboots the Routing Engine when pressed.
• Offline button—Takes the Routing Engine offline when pressed.
• Four LEDs— CF , DISK1 , DISK2 , and ONLINE .
• Extractor clips—Control the locking system that secures the Routing Engine.
40 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
RE-C1800 Boot Order
The RE-C1800 Routing Engine boots from the storage media in this order: the USB device, then the CompactFlash card (if present), then DISK1 , then the LAN.
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Routing Engine Description on page 39
• T4000 Control Board Description on page 36
• T4000 Craft Interface LEDs on page 25
T4000 RE-C1800 LEDs
Figure 22 on page 41 shows the RE-C1800 LEDs.
Table 15 on page 41 describes the functions of the LEDs on the faceplate of the Routing Engine.
Figure 22: RE-C1800 LEDs
CF
D
I
S
K
1
D
I
S
K
2
USB
Online
CF
S
K
D
I
1
S
K
D
I
2
USB
Offline
Online
Reset
Reset
NOTE: The LEDs on the Routing Engine do not necessarily indicate routing-related activity.
Table 15: Routing Engine C1800 LEDs
Label Color State Description
CF Green On steadily Indicates disk activity on the CompactFlash card.
DISK1
—
Green
—
Off
On steadily
Off
There is no disk activity on the CompactFlash card.
Indicates activity for the disk.
There is no activity for the disk.
Copyright © 2013, Juniper Networks, Inc.
41
T4000 Router Hardware Guide
Table 15: Routing Engine C1800 LEDs
(continued)
Label Color State Description
DISK2
ONLINE
Green
—
Green
On steadily
Off
On steadily
Not applicable.
NOTE: DISK2 is not currently supported.
Routing Engine is functioning normally.
USB
Red
—
Green
—
On steadily
Off
On steadily
Off
Routing Engine is not functioning normally.
Routing Engine is not online or not functioning normally.
Indicates activity on the USB port.
There is no activity on the USB port.
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 Craft Interface LEDs on page 25
T4000 PIC Description
PICs provide the physical connection to various network media types, receiving incoming packets from the network and transmitting outgoing packets to the network. During this process, each PIC performs framing and line-speed signaling for its media type. Before transmitting outgoing data packets, the PICs encapsulate the packets received from the
FPCs. Each PIC is equipped with an ASIC that performs control functions specific to the media type of that PIC.
The router supports various PICs, including ATM, Ethernet, and SONET/SDH interfaces.
Blank PICs resemble other PICs but do not provide any physical connection or activity.
When a slot is not occupied by a PIC, you must insert a blank PIC to fill the empty slot and ensure proper cooling of the system.
PICs are hot-removable and hot-insertable. Type 2 PICs have captive screws at their upper and lower corners. Type 3 PICs have an upper ejector handle and a lower captive screw. Type 4 and Type 5 PICs have an upper ejector handle and a lower ejector handle.
Table 16 on page 42 indicates the number of PICs supported by each FPC.
Table 16: Number of PICs Supported in Each FPC
FPC Name FPC Model Number Maximum Number of PICs
Enhanced Scaling FPC2 T640-FPC2-ES 4
42 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
Table 16: Number of PICs Supported in Each FPC
(continued)
FPC Name FPC Model Number Maximum Number of PICs
Enhanced Scaling FPC3
T1600 Enhanced Scaling FPC4
Enhanced Scaling FPC4-1P
T4000 FPC5
T640-FPC3-ES
T1600-FPC4-ES
T640-FPC4-1P-ES
NOTE: T640-FPC4-ES is not supported.
1
T4000-FPC5-3D 2
4
2
Related
Documentation
• T4000 PICs Supported
• Maintaining T4000 PICs
• Troubleshooting T4000 PICs
T4000 Power System Overview
• T4000 Power System Description on page 43
• T4000 Six-Input DC Power Supply LEDs on page 45
T4000 Power System Description
• Power Supply Slots on page 43
• Power Supply Function on page 43
• Supported Power Supplies on page 43
• Power Supply Components on page 44
• Redundancy on page 44
Power Supply Slots
The T4000 router has two redundant, load-sharing power supplies, located at the lower rear of the chassis in slots PEM0 and PEM1 (top to bottom). Power supplies are hot-removable and hot-insertable.
Power Supply Function
The power supplies connect to the midplane, which distributes the different output voltages produced by the power supplies to the T4000 router components, depending on their voltage requirements.
Supported Power Supplies
The T4000 router supports the power supply in Table 17 on page 44 .
Copyright © 2013, Juniper Networks, Inc.
43
T4000 Router Hardware Guide
Table 17: Supported Power Supplies
Name
Six-input DC power supply
Model Number
PWR-T-6-60-DC
First Supported Junos OS
Release
12.1
Power Supply Components
Each six-input DC power supply weighs approximately 39.7 lb (18.0 kg) and consists of six inputs, two blowers, a front and side air filter, and LEDs to monitor the status of the power supply. Each power supply is cooled by its own internal cooling system.
Figure 23 on page 44 shows the six-input DC power supply.
The six-input DC power supply inputs are labeled INPUT 0 , INPUT 1 , INPUT 2 , INPUT 3 ,
INPUT 4 , and INPUT 5 , from top to bottom. Each 60 A input consists of –48 VDC and return.
NOTE: There are no circuit breakers or passive fuses in the router.
Figure 23: DC Power Supply
44
Table 18 on page 44 describes which components are powered by each input.
Table 18: Components Powered by Each Six-Input DC Power Supply Input
Input Components
INPUT 0
INPUT 1 through INPUT 5
Fan trays
FPCs, Routing Engines, control boards, SIBs, craft interface, SCGs, and other components in the router.
Redundancy
When the T4000 router is operating normally and both power supplies are switched on, load sharing between them occurs automatically. When one power supply fails or is turned off, the other power supply immediately assumes the entire electrical load for
Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview the system. A single power supply can provide full power for as long as the router is operational.
Related
Documentation
• T4000 Six-Input DC Power Supply LEDs on page 45
• Maintaining the T4000 Power System on page 186
• Troubleshooting the T4000 Power System on page 204
T4000 Six-Input DC Power Supply LEDs
The LEDs on the faceplate of each power supply (see Table 19 on page 45 ) indicate the status of the power supply. The DC OK , OVERTEMP , and INPUT PRESENT LEDs are located on the faceplate of the power supply. A power supply failure also triggers the red alarm
LED on the craft interface.
Table 19 on page 45 describes the six-input DC power supply LEDs on the faceplate.
Table 19: Power Supply LEDs
LED Color State Description
INPUT
PRESENT —One per input
Green
–
On steadily
Off
DC OK —One per power supply
Blue
–
OVERTEMP —One per power supply
Yellow
–
On steadily
Off
On steadily
Off
Input is receiving voltage within the required range of –40 V through
–72 V.
Input voltage is not present, or the voltage is not within the required range of –40 V through –72 V.
When input 0 and at least one other input is properly energized and the power switch is ON, this input indicates that the power supply is functioning normally.
Power supply is starting up or is not receiving any input voltage.
The power switch on the power supply faceplate or the customer site external circuit breakers might be off. A fault might have occurred.
Power supply has exceeded the recommended temperature and has been powered off.
The power supply is within the recommended temperature, or the power supply is not receiving any input voltage.
Related
Documentation
• T4000 Power System Description on page 43
• Maintaining the T4000 Power System on page 186
• Troubleshooting the T4000 Power System on page 204
T4000 Switch Interface Board (SIB) Overview
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000-SIB Description on page 46
Copyright © 2013, Juniper Networks, Inc.
45
T4000 Router Hardware Guide
• T4000 TXP-LCC-3D SIB Description on page 47
• T4000 SIB LEDs on page 48
T4000 Switch Interface Board (SIB) Description
SIBs create the switch fabric for the T4000 Core Router. Each T4000 router contains five SIBs, located at the center rear of the chassis in the slots labeled SIB0 through SIB4
(top to bottom). One of the five SIBs acts as a backup to the remaining four SIBs. If a SIB fails, the backup SIB becomes active, and traffic forwarding continues without any degradation. When the failed SIB is replaced, it becomes the new backup. SIBs are hot-insertable and hot-removable.
The T4000 router supports the SIB listed in Table 20 on page 46 .
Table 20: T4000 Supported SIB
Name Model Number First Supported Junos OS Release
T4000-SIB
NOTE: This SIB is required for a standalone T4000 router.
SIB-I-T4000 12.1
TXP-LCC-3D SIB
NOTE: This SIB is required for a
T4000 line-card chassis connected to a TX Matrix Plus Router.
SIB-TXP-3D-LCC 13.1
Related
Documentation
• T4000-SIB Description on page 46
• T4000 TXP-LCC-3D SIB Description on page 47
• T4000 Router Description on page 3
T4000-SIB Description
Figure 24 on page 46 shows a T4000-SIB that is required for a standalone T4000 router.
Figure 24: T4000-SIB
Each T4000-SIB consists of the following components:
• Switch fabric ASICs.
• High-speed links to each FPC.
46 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
• SIB online/offline button, located on the SIB faceplate. The button is to signal a removal request by a user.
• Three LEDs— ACTIVE , OK , and FAIL —located on the SIB faceplate that display the status of the T4000-SIB. The OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000 SIB LEDs on page 48
• Maintaining the T4000 SIBs on page 186
• Replacing a T4000-SIB on page 279
T4000 TXP-LCC-3D SIB Description
Figure 25 on page 47 shows a TXP-LCC-3D SIB (model number SIB-TXP-3D-LCC) that is required to connect a T4000 line card chassis (LCC) to TXP-F13-3D SIBs in a TX Matrix
Plus router. See TX Matrix Plus Router Hardware Guide .
Figure 25: TXP-LCC-3D SIB
SIB status
LEDs
ONLINE/
OFFLINE button
ONLINE/
OFFLINE
OK
FAIL
ACTIVE
Ports: 0 1 2 3 4 5 6 7 Port LEDs
Each TXP-LCC-3D SIB consists of the following components:
• Eight ports labeled 0 through 7 . Each port has a CBL and LINK LED.
• Switch fabric ASICs.
• High-speed links to each FPC.
• SIB online/offline button, located on the SIB faceplate. The button is to signal a removal request by a user.
• Three LEDs— OK , FAIL , and ACTIVE —located on the SIB faceplate that display the status of the TXP-LCC-3D SIB. The OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000 SIB LEDs on page 48
• Maintaining the T4000 SIBs on page 186
• Replacing a T4000-SIB on page 279
Copyright © 2013, Juniper Networks, Inc.
47
T4000 Router Hardware Guide
T4000 SIB LEDs
Table 21 on page 48 describes the functions of the T4000-SIB LEDs and TXP-LCC-3D
SIB LEDs. If all three LEDs are off, the SIB is not receiving power. The craft interface has three additional LEDs that show the status of each SIB.
Table 21: T4000 and TXP-LCC-3D SIB LEDs
Label Color State Description
ACTIVE Green On steadily
Off
SIB is in active mode.
SIB is in standby mode.
NOTE: This LED has significance only if the ONLINE LED is lit.
OK
FAIL
Green
Red
On steadily
Blinking
Off
On steadily
Off
SIB is functioning normally.
SIB is starting up.
SIB has been inserted or is ready for removal.
SIB has failed.
SIB is functioning normally.
The TXP-LCC-3D SIB port LEDs are located beneath each port (see Figure 26 on page 48 ).
Each port has a Link and CBL LED.
Table 22 on page 49 describes the functions of these
LEDs.
Figure 26: TXP-3D-LCC SIB LEDs
OK
FAIL
ACTIVE
OK
FAIL
ACTIVE
ONLINE/
OFFLINE
48 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
Table 22: TXP-LCC-3D SIB Port LEDs
Label Color State Description
LINK Green On steadily
Yellow
Blinking
On steadily
Blinking
The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port has been established successfully.
The link between the TXP-LCC-3D SIB port and the loopback connector has been established successfully.
The link is being established.
The switching plane cable might be connected to either the wrong TXP-LCC-3D
SIB port or the wrong TXP-FI3-3D port.
Red On steadily
CBL
–
Green
Yellow
Red
Off
Off
On steadily
On steadily
Off
–
The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port failed.
There might be a hardware problem, or the fiber-optic port or cable might need to be cleaned.
The cable is not connected on both sides, or either the TXP-F13-3D SIB or the
TXP-LCC-3D SIB is powered off.
Full optical power is being received.
Diminished optical power is being received. The switching plane cable or the switching plane port might need cleaning, or the cable might be damaged.
Optical power has crossed operating thresholds. The switching plane cable is not connected to the TXP-FI3-3D SIB port, or is not connected to the TXP-LCC-3D
SIB port. If the cable is connected on both sides, the cable might be cut.
No optical power is detected. Cable is damaged or absent.
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000 TXP-LCC-3D SIB Description on page 47
T4000 SONET Clock Generators (SCGs) Overview
• T4000 SONET Clock Generators (SCGs) Description on page 49
• T4000 SONET Clock Generators (SCGs) LEDs on page 51
T4000 SONET Clock Generators (SCGs) Description
• SCG Slots on page 50
• SCG Function on page 50
• SCG Redundancy on page 50
• Supported SCGs on page 50
• SCG Components on page 50
Copyright © 2013, Juniper Networks, Inc.
49
T4000 Router Hardware Guide
SCG Slots
The SCGs are installed into the upper rear of the chassis in the slots labeled SCG0 and
SCG1 .
SCG Function
SCGs provide 19.44-MHz Stratum 3 clock signal for the SONET/SDH interfaces on the router.
SCG Redundancy
One SCG is shipped as part of the standard router configuration, but up to two SCGs can be installed to provide redundancy. A nonredundant SCG is hot-pluggable. For redundant
SCGs, the master SCG is hot-pluggable. If the master SCG is functioning, the backup
SCG is hot-removable and hot-insertable. Removing the backup SCG does not affect the functioning of the router. Taking the master SCG offline might result in a brief loss of
SONET clock lock while the backup SCG becomes the master.
Supported SCGs
The T4000 router supports the SCG in Table 23 on page 50 .
NOTE: Redundant SCGs must be the same model number, except during upgrade.
Table 23: Supported SCG
Name
SCG with RJ-48 ports
SCG with DB-9 ports
Model Number
SCG-T-EC
SCG-T
First Supported Junos OS
Release
12.1
12.1
SCG Components
The SCG with DB-9 ports is shown in Figure 27 on page 50 .
Figure 27: SCG with DB-9 Ports
50 Copyright © 2013, Juniper Networks, Inc.
Chapter 3: T4000 Hardware Components Overview
The SCG with RJ-48 ports is shown in Figure 28 on page 51 .
Figure 28: SCG with RJ-48 ports
Online/Offline button
EXTERNAL CLOCK INPUTS
OK Fail Master
Each SCG consists of the following components:
• 19.44-MHz Stratum 3 clock.
• Field-programmable gate array (FPGA) that performs multiplexing of clock sources.
• SCG online/offline button, located on the SCG faceplate.
• Two external clock inputs.
NOTE: The external clock ports are not supported on the SCG with DB-9 ports.
For information about configuring external clock synchronization for T Series routers, see the Junos OS Administration Library for Routing Devices .
For information about configuring an interface transmit clock, see the Router Interfaces .
• Three LEDs— OK , FAIL , and MASTER , located on the SCG faceplate, that display the status of the SCG.
Related
Documentation
• T4000 SONET Clock Generators (SCGs) LEDs on page 51
• Connecting the T4000 Router to an External Clocking Device on page 115
• Maintaining the T4000 SCGs on page 187
• Troubleshooting the T4000 SCGs on page 208
T4000 SONET Clock Generators (SCGs) LEDs
Three LEDs, located on the SCG faceplate, display the status of the SCG.
Table 24 on page 52 describes the functions of the SCG LEDs. Two LINK LEDs, located on the left of each RJ-48 port, display the status of the external clock inputs links. The other LEDs on the right of each port are not used.
Figure 29 on page 52 shows the LEDs on the SCG with RJ-48 ports.
Copyright © 2013, Juniper Networks, Inc.
51
T4000 Router Hardware Guide
Figure 29: SCG with RJ-48 ports
Online/Offline button
EXTERNAL CLOCK INPUTS
OK Fail Master
Table 24 on page 52 describes the functions of the SCG LEDs. The LINK LED is not applicable to the SCG with DB-9 ports.
Table 24: SCG LEDs
Label Color State Description
OK Green On steadily
Off
SCG is online and is functioning normally.
SCG is not online or not functioning normally.
FAIL
MASTER
LINK
Yellow
Blue
Green
On steadily
Off
On steadily
Off
On Steadily
Off
SCG has failed.
SCG is offline or functioning normally.
SCG is functioning as master.
SCG is not functioning as the master.
Link is online and active.
No link.
Related
Documentation
• T4000 SONET Clock Generators (SCGs) Description on page 49
• Connecting the T4000 Router to an External Clocking Device on page 115
• Maintaining the T4000 SCGs on page 187
• Troubleshooting the T4000 SCGs on page 208
52 Copyright © 2013, Juniper Networks, Inc.
PART 2
T4000 Router Initial Installation
• T4000 Router Installation Summary on page 55
• Preparing for T4000 Router Installation on page 57
• Unpacking the T4000 Router on page 61
• Installing the T4000 Router Mounting Hardware on page 67
• Installing the T4000 Router into a Rack on page 75
• Installing the T4000 Router Using a Mechanical Lift on page 77
• Installing the T4000 Router Without a Mechanical Lift on page 85
• Grounding the T4000 Router on page 109
• Connecting the T4000 Router to External Devices on page 111
• Providing Power to the T4000 Router on page 121
• Configuring Junos OS on page 145
Copyright © 2013, Juniper Networks, Inc.
53
T4000 Router Hardware Guide
54 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 4
T4000 Router Installation Summary
• Overview of Installing the T4000 Router on page 55
Overview of Installing the T4000 Router
You must proceed through the installation process in the following order:
1.
Review all safety guidelines and warnings for the router.
WARNING: To avoid harm to yourself or the router as you install and maintain it, you must follow the safety procedures for working with Internet routers, as well as the guidelines and warnings for working with and near electrical equipment. However, providing an exhaustive set of guidelines for working with electrical equipment is beyond the scope of this documentation.
See “General Safety Guidelines for Juniper Networks Devices” on page 293 .
2.
Prepare the installation site for the router.
See “Overview of Preparing the Site for the T4000 Router” on page 57 .
3.
Unpack the router and verify the parts received.
See “Overview of Unpacking the T4000 Router” on page 61 .
4.
Install the mounting hardware. See:
• “Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet” on page 67 .
• “Installing the T4000 Mounting Hardware for an Open-Frame Rack” on page 70 .
5.
Install the router into the rack. See:
• Overview of Installing the T4000 Router into a Rack on page 75
• Overview of Installing a T4000 Router Using a Mechanical Lift on page 77
• Overview of Installing a T4000 Router Without a Mechanical Lift on page 85
6.
Ground the router.
See “Connecting the T4000 Grounding Cable” on page 110 .
Copyright © 2013, Juniper Networks, Inc.
55
T4000 Router Hardware Guide
7.
Connect the router to external devices. See:
• Overview of Connecting the T4000 Router to External Devices on page 111
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
• Connecting the T4000 Router to an External Alarm-Reporting Device on page 114
• Connecting the T4000 Router to an External Clocking Device on page 115
• Connecting PIC Cables to the T4000 Router on page 116
• Connecting the T4000 Router to a Management Ethernet Device on page 118
8.
Connect the power. See:
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six
60-A Inputs) on page 133
9.
Power on the router.
See “Powering On the T4000 Router” on page 141 .
Related
Documentation
• T4000 Router Description on page 3
56 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 5
Preparing for T4000 Router Installation
• Overview of Preparing the Site for the T4000 Router on page 57
• Rack Requirements for the T4000 Router on page 58
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
Overview of Preparing the Site for the T4000 Router
To prepare a site for router installation:
1.
Verify that environmental factors such as temperature and humidity do not exceed router tolerances.
See “T4000 Router Environmental Specifications” on page 333 .
2.
Verify that the site and installation plan meets all safety guidelines and requirements.
See “General Safety Guidelines for Juniper Networks Devices” on page 293 .
3.
Measure distance between external power sources and the router installation site.
See:
• T4000 DC Power Distribution on page 343
• T4000 DC Power Cable and Lugs Specifications on page 341
• T4000 DC Power Requirements on page 338
• T4000 DC Power Supply Specifications on page 337
• T4000 DC Power System Electrical Specifications on page 336
4.
Locate sites for connection of system grounding.
See “T4000 Chassis Grounding Cable and Lug Specifications” on page 335 .
5.
Calculate the power consumption and requirements.
See “T4000 DC Power Requirements” on page 338 .
6.
Verify that the plan for power installation meets all electrical safety guidelines. See:
• T4000 General Electrical Safety Guidelines on page 314
• T4000 DC Power Electrical Safety Guidelines on page 320
7.
Verify that your rack meets the minimum requirements for the installation of the router.
Copyright © 2013, Juniper Networks, Inc.
57
T4000 Router Hardware Guide
See “Rack Requirements for the T4000 Router” on page 58 .
8.
Plan the location of the rack, including required space for airflow and maintenance.
See “T4000 Clearance Requirements for Airflow and Hardware Maintenance” on page 59 .
9.
Plan to secure the rack to the floor and building structure.
See “Rack Requirements for the T4000 Router” on page 58 .
10.
Acquire cables and connectors:
• Determine the number of cables needed based on your planned configuration.
• Review the maximum distance allowed for each cable. Choose the length of cable based on the distance between the hardware components being connected.
See the T4000 Interface Module Reference .
11.
Plan the cable routing and management.
See “Maintaining T4000 PICs” on page 184 .
Related
Documentation
• Overview of Installing the T4000 Router on page 55
Rack Requirements for the T4000 Router
The router can be installed in many types of racks, including four-post (telco) racks and open-frame racks. An example of an open-frame rack is shown in Figure 30 on page 59 .
For open-frame racks, center-mounting is preferable to front-mounting because the more even distribution of weight provides greater stability.
The router is designed for installation in a 19-in. rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics
Industry Association ( http://www.eia.org
).
With the use of adapters, the router can fit into a 600-mm-wide rack, as defined in the four-part Equipment Engineering (EE); European Telecommunications Standard for
Equipment Practice (document numbers ETS 300 119-1 through 119-4) published by the
European Telecommunications Standards Institute ( http://www.etsi.org
). Use approved wing devices to narrow the opening between the rails.
The rack rails must be spaced widely enough to accommodate the router chassis's external dimensions: 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide, excluding the front and rear cable management systems. The outer edges of the mounting brackets extend the width to 19 in. (48.3 cm). The spacing of rails and adjacent racks must also allow for the clearances around the router and rack.
The mounting holes for connecting the mounting brackets to the chassis are spaced
0.984 in. (25 mm) apart.
58 Copyright © 2013, Juniper Networks, Inc.
Chapter 5: Preparing for T4000 Router Installation
The chassis height of 37.45 in. (95.1 cm) is approximately 21.4 U. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310-D) published by the Electronics Industry Association. You can stack two routers in a rack that has at least 42.8 U (74.9 in. or 1.90 m) of usable vertical space.
The rack must be strong enough to support the weight of the fully configured router, up to 606 lb (275 kg). If you stack two fully configured routers in one rack, it must be capable of supporting about 1212 lb (550 kg).
Figure 30: Typical Open-Frame Rack
Always secure the rack to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets.
Related
Documentation
• T4000 Router Physical Specifications on page 331
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
T4000 Clearance Requirements for Airflow and Hardware Maintenance
When planning the installation site, you need to allow sufficient clearance around the rack (see Figure 31 on page 60 ):
Copyright © 2013, Juniper Networks, Inc.
59
T4000 Router Hardware Guide
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
NOTE: If you mount the router in a cabinet, be sure that ventilation is sufficient to prevent overheating.
• For service personnel to remove and install hardware components, there must be adequate space at the front and back of the router. At least 24 in. (61 cm) are required both in front of and behind the router. NEBS GR-63 recommends that you allow at least 30 in. (72.6 cm) behind the rack.
Figure 31: Chassis Dimensions and Clearance Requirements
30" (76.2 cm) clearance recommended for maintenance
31 "
(78.7 cm)
30" (76.2 cm) clearance recommended for maintenance
(without rear cable management system)
Front of chassis
19.2"
(48.7 cm)
17.4"
(44.2 cm)
Rear of chassis
Front-mounting flange
Center-mounting bracket
2.4"
(6.1 cm)
19.8" (50.3 cm) width with rear cable managment system
30" (76.2 cm) clearance recommended for maintenance
(with rear cable
9.5"
(24.1 cm) management system) depth for optional rear cable managment system
Related
Documentation
• T4000 Cooling System Description on page 21
• Rack Requirements for the T4000 Router on page 58
• T4000 Router Physical Specifications on page 331
60 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 6
Unpacking the T4000 Router
• Overview of Unpacking the T4000 Router on page 61
• Tools and Parts Required to Unpack the T4000 Router on page 61
• Unpacking the T4000 Router on page 62
• Verifying the T4000 Router Parts Received on page 63
Overview of Unpacking the T4000 Router
To unpack the router:
1.
Gather the tools required to unpack the router.
See “Tools and Parts Required to Unpack the T4000 Router” on page 61 .
2.
Remove the router, accessory box, tool kit, and all parts from the shipping crate.
See “Unpacking the T4000 Router” on page 62
3.
Verify that all parts have been received.
See “Verifying the T4000 Router Parts Received” on page 63 .
Related
Documentation
• Overview of Installing the T4000 Router on page 55
Tools and Parts Required to Unpack the T4000 Router
To unpack the router and prepare for installation, you need the following tools:
• Phillips (+) screwdriver, number 2
• 1/2-in. or 13-mm open-end or socket wrench to remove bracket bolts from the shipping pallet
• Blank panels to cover any slots not occupied by a component
Related
Documentation
• Overview of Unpacking the T4000 Router on page 61
• Unpacking the T4000 Router on page 62
• Verifying the T4000 Router Parts Received on page 63
Copyright © 2013, Juniper Networks, Inc.
61
T4000 Router Hardware Guide
Unpacking the T4000 Router
The router is shipped in a wooden crate. A wooden pallet forms the base of the crate.
The router chassis is bolted to this pallet. Quick Start installation instructions and a cardboard accessory box are also included in the shipping crate.
The shipping crate measures:
• 51 in. (129 cm) high
• 35 in. (89 cm) wide
• 43 in. (110 cm) deep
The total weight of the crate containing the router and accessories can range up to 392 lb
(178 kg).
NOTE: The router is maximally protected inside the shipping crate. Do not unpack it until you are ready to begin installation.
To unpack the router (see Figure 32 on page 63 ):
1.
Move the shipping crate to a staging area as close to the installation site as possible, where you have enough room to remove the components from the chassis. While the chassis is bolted to the pallet, you can use a forklift or pallet jack to move it.
2.
Position the shipping crate with the arrows pointing up.
3.
Open all the latches on the shipping crate.
4.
Remove the front door of the shipping crate cover and set it aside.
5.
Slide the remainder of the shipping crate cover off the pallet.
6.
Remove the foam covering the top of the router.
7.
Remove the accessory box and the Quick Start documentation.
8.
Verify the parts received against the lists in “Verifying the T4000 Router Parts
Received” on page 63 .
9.
Remove the vapor corrosion inhibitor (VCI) packs attached to the pallet, being careful not to break the VCI packs open.
10.
To remove the brackets holding the chassis on the pallet, use a 1/2-in. socket wrench and a number 2 Phillips screwdriver to remove the bolts and screws from the brackets.
11.
Store the brackets and bolts inside the accessory box.
12.
Save the shipping crate cover, pallet, and packing materials in case you need to move or ship the router at a later time.
62 Copyright © 2013, Juniper Networks, Inc.
Figure 32: Contents of the Shipping Crate
Chapter 6: Unpacking the T4000 Router
Related
Documentation
• Overview of Unpacking the T4000 Router on page 61
• Tools and Parts Required to Unpack the T4000 Router on page 61
• Verifying the T4000 Router Parts Received on page 63
Verifying the T4000 Router Parts Received
A packing list is included in each shipment. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and descriptions of each part in your order.
If any part is missing, contact a customer service representative.
The main shipment contains the router chassis with installed components, listed in
Table 25 on page 63 , and an accessory box, which contains the parts listed in
Table 26 on page 65 .
Table 25: Router Parts List
Component Quantity
Chassis, including midplane, craft interface
FPCs
PICs
SIBs
1
Up to 8
Up to 4 per FPC
5
Copyright © 2013, Juniper Networks, Inc.
63
T4000 Router Hardware Guide
Table 25: Router Parts List
(continued)
Component Quantity
Routing Engines
Control boards
SCGs
Power supplies
1 or 2
1 or 2 (one for each Routing Engine)
1 or 2
2
CIP
Front fan trays
Rear fan tray
Quick Start installation
Large mounting shelf—Required for all mounting options.
Small mounting shelf—Required only for four-post rack or cabinet
Spacer bars (attached to the back of the front-mounting flanges on the chassis—Required only for four-post rack or cabinet
Blank panels for slots without components installed
1
1
1
2
1
1
2
One blank panel for each slot not occupied by a component
64 Copyright © 2013, Juniper Networks, Inc.
Chapter 6: Unpacking the T4000 Router
Table 26: Accessory Box Parts List
Part Quantity
Affidavit for T1 connection
Connectors for alarm relay cables
DB-9 (male) to DB-25
(female) adapter
ESD wrist strap with cable
1
2
1
1
Ethernet cable, 15-ft length, to connect Routing Engine to management device
1
PCMCIA Card holder and hook-and-loop fasteners
(male and female)
1 of each
DC power and grounding cable lugs
36 lugs are included.
One lug is for the grounding cable. The remaining cable lugs are for the DC power cables. The number of cable lugs varies depending on the power supply and how many cables are being connected.
Screws to fasten grounding cable to chassis
2
Washers for grounding cable lug
2
Optional cable management restraints
2
Product warranty
Read me first document
1
1
Screws to mount chassis
Serial cable, 6-ft length, to connect Routing Engine to management console
End User License Agreement 1
Bag of 14
1
Related
Documentation
• Overview of Unpacking the T4000 Router on page 61
• Unpacking the T4000 Router on page 62
Copyright © 2013, Juniper Networks, Inc.
65
T4000 Router Hardware Guide
66 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 7
Installing the T4000 Router Mounting
Hardware
• Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet on page 67
• Installing the T4000 Mounting Hardware for an Open-Frame Rack on page 70
Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet
1.
Installing Cage Nuts, if Needed on page 67
2.
Installing the Large Mounting Shelf on page 68
3.
Installing the Small Shelf on page 69
4.
Installing the Spacer Bars on page 70
Installing Cage Nuts, if Needed
To install the cage nuts, if needed, in the mounting holes specified in Table 27 on page 67 :
1.
On the front rack rails, install cage nuts in the holes specified for the large shelf and the spacer bars.
2.
On the rear rack rails, install cage nuts in the holes specified for the small shelf.
The front-mounting flanges have holes for rack-mounting screws, spaced at 5.25 in.
(13.34 cm).
Table 27 on page 67 specifies the holes in which you insert mounting screws
(an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard U divisions on the rack. The bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 27: Four-Post or Cabinet Rack Mounting Hole Locations
Hole Distance Above U Division
Large
Shelf
Spacer
Bars
Small
Shelf
60
51
42
34.75 in. (88.3 cm)
29.51 in. (74.9 cm)
24.26 in. (61.6 cm)
19.86 U
16.86 U
13.86 U
X
X
X
Copyright © 2013, Juniper Networks, Inc.
67
T4000 Router Hardware Guide
6
3
2
15
12
33
24
9
Table 27: Four-Post or Cabinet Rack Mounting Hole Locations
(continued)
Hole Distance Above U Division
Large
Shelf
Spacer
Bars
Small
Shelf
19.01 in. (48.3 cm)
13.76 in. (34.9 cm)
8.51 in. (21.6 cm)
6.76 in. (17.1 cm)
5.01 in. (12.7 cm)
10.86 U
7.86 U
4.86 U
3.86 U
2.86 U
X
X
X X
X
X
3.26 in. (8.3 cm)
1.51 in. (3.8 cm)
0.88 in. (2.2 cm)
1.86 U
0.86 U
0.50 U X
X X
X
Installing the Large Mounting Shelf
To install the large mounting shelf:
1.
On the front of each front rack rail, partially insert a mounting screw into the lowest hole specified in Table 27 on page 67 for the large shelf and the spacer bars.
2.
Install the large shelf on the front rack rails. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert a mounting screw into the top hole in each flange of the large shelf.
4.
Tighten all the screws completely.
68 Copyright © 2013, Juniper Networks, Inc.
Chapter 7: Installing the T4000 Router Mounting Hardware
Figure 33: Installing the Mounting Hardware for a Four-Post Rack or
Cabinet
Installing the Small Shelf
To install the small shelf:
1.
On the back of each rear rack rail, partially insert a mounting screw into the lowest hole specified in Table 27 on page 67 for the small shelf.
2.
Install the small shelf on the back rack rails. Rest the bottom slot of each flange on a mounting screw. The small shelf installs on the back of the rear rails, extending toward the center of the rack. The bottom of the small shelf on the rear rack rails must align with the bottom of the large shelf on the front rack rails.
3.
Partially insert screws into the open holes in the flanges of the small shelf.
4.
Tighten all the screws completely.
Copyright © 2013, Juniper Networks, Inc.
69
T4000 Router Hardware Guide
Installing the Spacer Bars
The router is shipped with each spacer bar attached to the rear of each front-mounting flange.
To install the spacer bars:
1.
Remove each spacer bar by removing the screws that fasten the spacer bar to the front-mounting flange.
2.
Place one of the spacer bars over a flange of the large shelf. Position the notch in the rear of the spacer bar so the upper part of the bar is flush with the rack rail and the lower part is flush with the flange of the shelf (see Figure 34 on page 70 ).
3.
Insert a mounting screw into each of the nonthreaded holes in the recesses of the spacer bar to secure the spacer bar. Each hole should have a cage nut behind it.
4.
Repeat Steps 2 and 3 for the other spacer bar.
5.
Tighten all the screws completely.
Figure 34: Positioning the Spacer Bar on the Rack
Related
Documentation
• Rack Requirements for the T4000 Router on page 58
• Installing the T4000 Mounting Hardware for an Open-Frame Rack on page 70
Installing the T4000 Mounting Hardware for an Open-Frame Rack
In an open-frame rack, center-mounting is generally preferable to front-mounting because the more even distribution of weight provides greater stability. If you center-mount the
70 Copyright © 2013, Juniper Networks, Inc.
Chapter 7: Installing the T4000 Router Mounting Hardware chassis, you use the center-mounting brackets attached to the chassis. If you front-mount the chassis, you use the front-mounting flanges, and must remove the center-mounting brackets.
1.
Installing the Cage Nuts, if Needed on page 71
2.
Installing the Large Mounting Shelf on page 71
3.
Removing the Center-Mounting Brackets from the Chassis on page 72
4.
Removing the Spacer Bars on page 73
Installing the Cage Nuts, if Needed
1.
Check that cage nuts are installed in the mounting holes specified in
Table 28 on page 71 .
2.
Install cage nuts, if needed.
Table 28 on page 71 specifies the mounting holes in which you insert the mounting screws
(an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard U divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 28: Open-Frame Rack Mounting Hole Locations
Hole Distance Above U Division Large Shelf
59 34.13 in. (86.7 cm) 19.50 U X
32
31
53
50
44
41
35
30.63 in. (77.8 cm)
28.88 in. (73.3 cm)
25.38 in. (64.5 cm)
23.63 in. (60.0 cm)
20.13 in. (51.1 cm)
18.38 in. (46.7 cm)
17.75 in. (45.1 cm)
17.50 U
16.50 U
14.50 U
13.50 U
11.50 U
10.50 U
10.14 U
X
X
X
X
X
X
X
Installing the Large Mounting Shelf
To install the large mounting shelf (see Figure 35 on page 72 ) in an open-frame rack:
1.
On the rear of each rack rail, partially insert a mounting screw into the lowest hole specified in Table 28 on page 71 for the large shelf.
2.
Install the large shelf on the rack. Rest the bottom slot of each flange on a mounting screw.
Copyright © 2013, Juniper Networks, Inc.
71
T4000 Router Hardware Guide
3.
Partially insert screws into the open holes in the flanges of the large shelf.
4.
Tighten all the screws completely.
Figure 35: Installing the Mounting Hardware for an Open-Frame Rack
Removing the Center-Mounting Brackets from the Chassis
Before front-mounting the router in an open-frame rack, you must remove the center-mounting brackets from the chassis.
To remove the center-mounting brackets (see Figure 36 on page 73 ):
1.
Loosen the screws at the top and bottom of each bracket.
2.
Remove each bracket.
72 Copyright © 2013, Juniper Networks, Inc.
Chapter 7: Installing the T4000 Router Mounting Hardware
Figure 36: Removing the Center-Mounting Bracket
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
ESD point
Air filter
Fan tray
Air intake
Removing the Spacer Bars
The router is shipped with each spacer bar attached to the rear of each front-mounting flange. If you are installing the chassis in an open-frame rack, removing the spacer bars is optional.
To remove the spacer bars:
1.
Remove the screws that fasten the spacer bar to the front-mounting flange
2.
Remove the spacer bars.
Related
Documentation
• Rack Requirements for the T4000 Router on page 58
• Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet on page 67
Copyright © 2013, Juniper Networks, Inc.
73
T4000 Router Hardware Guide
74 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 8
Installing the T4000 Router into a Rack
• Overview of Installing the T4000 Router into a Rack on page 75
Overview of Installing the T4000 Router into a Rack
1.
Read the safety information. To avoid harm to yourself or the router as you lift it into the rack, follow the guidelines and safety procedures for working with routers.
See “T4000 Installation Safety Guidelines” on page 300 and “General Safety Guidelines for Juniper Networks Devices” on page 293 .
2.
Verify that the site has been prepared for the router installation.
See “Overview of Preparing the Site for the T4000 Router” on page 57 .
3.
Because of the T4000 router's size and weight—up to 663.6 lb (301.0 kg) fully configured—we strongly recommend that you lift the router into the rack using a mechanical lift. See “Overview of Installing a T4000 Router Using a Mechanical Lift” on page 77
However, if a mechanical lift is not available, you can remove components from the chassis to make it easier to install into the rack. With components removed, the chassis weighs approximately 240 lb (109 kg), and four people can lift the chassis into the rack manually. See “Overview of Installing a T4000 Router Without a Mechanical Lift” on page 85 .
Related
Documentation
• Overview of Installing the T4000 Router on page 55
Copyright © 2013, Juniper Networks, Inc.
75
T4000 Router Hardware Guide
76 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 9
Installing the T4000 Router Using a
Mechanical Lift
• Overview of Installing a T4000 Router Using a Mechanical Lift on page 77
• Tools Required to Install the T4000 Router Using a Mechanical Lift on page 77
• Installing the T4000 Router Using a Mechanical Lift on page 78
Overview of Installing a T4000 Router Using a Mechanical Lift
Before installing the router, make sure that you have prepared your site, unpacked the router from the shipping crate, and installed the mounting hardware.
Because of the router's size and weight—up to 663.6 lb (301.0 kg), depending on the configuration—we strongly recommend that you install the router using a mechanical lift.
To install the router:
1.
Gather the tools required to install the router.
See “Tools Required to Install the T4000 Router Using a Mechanical Lift” on page 77 .
2.
Install the router into the rack using a mechanical lift.
See “Installing the T4000 Router Using a Mechanical Lift” on page 78 .
Related
Documentation
• Overview of Installing the T4000 Router into a Rack on page 75
Tools Required to Install the T4000 Router Using a Mechanical Lift
To install the T4000 chassis using a mechanical lift, you need the following tools:
• Mechanical lift
• Phillips (+) screwdrivers, number 2
Related
Documentation
• Overview of Installing a T4000 Router Using a Mechanical Lift on page 77
• Installing the T4000 Router Using a Mechanical Lift on page 78
Copyright © 2013, Juniper Networks, Inc.
77
T4000 Router Hardware Guide
Installing the T4000 Router Using a Mechanical Lift
1.
Removing the T4000 Power Supplies on page 78
2.
Attaching the T4000 Installation Handle on page 79
3.
Installing the T4000 Chassis in a Rack or Cabinet Using a Mechanical Lift on page 79
4.
Removing the T4000 Installation Handle on page 82
5.
Reinstalling the T4000 Power Supplies on page 83
Removing the T4000 Power Supplies
To remove the power supplies, start with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
3.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
4.
Grasp the handle on the power supply faceplate, and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see Figure 37 on page 78 .
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router.
5.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
6.
Repeat the procedure for the other power supply.
Figure 37: Removing a DC Power Supply
78 Copyright © 2013, Juniper Networks, Inc.
Chapter 9: Installing the T4000 Router Using a Mechanical Lift
Attaching the T4000 Installation Handle
To assist you with the installation of the router, attach the installation handle over the power supply slots of the chassis. To attach the installation handle:
1.
Place the installation handle over the location of the lower power supply.
2.
Tighten the captive screws of the handle into the holes previously occupied by the captive screws of the power supply (see Figure 38 on page 79 ).
Figure 38: Attaching the Installation Handle
Installing the T4000 Chassis in a Rack or Cabinet Using a Mechanical Lift
Because of the router's size and weight—up to 663.6 lb (301.0 kg) depending on configuration—we strongly recommend that you install the router using a lift.
To mount the chassis in the rack or cabinet using a lift (see Figure 39 on page 81 ):
1.
If you are installing the router in an open-frame rack, ensure that the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see “T4000
Clearance Requirements for Airflow and Hardware Maintenance” on page 59 .
2.
Load the router onto the lift, making sure it rests securely on the lift platform.
CAUTION: Do not lift the router using the installation handle or the handles on the sides of the chassis. Use these handles only to help position the router.
3.
Using the lift, position the chassis in front of the rack or cabinet, centering it in front of the mounting shelves.
4.
Lift the chassis approximately 0.75 in. above the surface of the mounting shelves, and position it as close as possible to the shelves.
Copyright © 2013, Juniper Networks, Inc.
79
T4000 Router Hardware Guide
5.
Carefully slide the chassis onto the mounting shelves so that the bottom of the chassis and the mounting shelves overlap by approximately 2 inches.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while two people push on the front-mounting flanges, slide the chassis onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
Move the lift away from the rack.
8.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
80 Copyright © 2013, Juniper Networks, Inc.
Figure 39: Lifting the Router
Chapter 9: Installing the T4000 Router Using a Mechanical Lift
Copyright © 2013, Juniper Networks, Inc.
81
T4000 Router Hardware Guide
Figure 40: Installing the Router in a Four-Post Rack
NOTE: For an illustration of the mounting hardware required for an open-frame rack, see “Installing the T4000 Mounting Hardware for an
Open-Frame Rack” on page 70 .
Removing the T4000 Installation Handle
After you have installed the router, remove the installation handle:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the installation handle completely.
3.
Remove the handle from the chassis.
82 Copyright © 2013, Juniper Networks, Inc.
Chapter 9: Installing the T4000 Router Using a Mechanical Lift
Reinstalling the T4000 Power Supplies
After you have removed the installation handle, reinstall the two power supplies in the chassis, starting with the lower power supply (see Figure 41 on page 83 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using both hands, slide the power supply into the chassis until you feel resistance.
3.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
4.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
5.
Repeat the procedure for the upper power supply.
Figure 41: Reinstalling the Power Supplies
Related
Documentation
• Overview of Installing a T4000 Router Using a Mechanical Lift on page 77
• Tools Required to Install the T4000 Router Using a Mechanical Lift on page 77
Copyright © 2013, Juniper Networks, Inc.
83
T4000 Router Hardware Guide
84 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 10
Installing the T4000 Router Without a
Mechanical Lift
• Overview of Installing a T4000 Router Without a Mechanical Lift on page 85
• Tools Required to Install the T4000 Router Without a Mechanical Lift on page 86
• Removing T4000 Components from the Chassis on page 86
• Installing the T4000 Chassis in a Rack or Cabinet Manually on page 98
• Reinstalling the T4000 Components in the Chassis on page 101
Overview of Installing a T4000 Router Without a Mechanical Lift
If you cannot use a mechanical lift to install the T1600 router (the preferred method), you can install it manually. Before installing the router, make sure that you have prepared your site, unpacked the router from the shipping crate, and installed the mounting hardware.
To install the router:
1.
Gather the tools required to install the router.
See “Tools Required to Install the T4000 Router Without a Mechanical Lift” on page 86 .
2.
Remove components from the chassis to make it easier to install into the rack.
See “Removing T4000 Components from the Chassis” on page 86 .
3.
Install the router into the rack.
See “Installing the T4000 Chassis in a Rack or Cabinet Manually” on page 98 .
4.
Reinstall the components removed from the chassis.
See “Reinstalling the T4000 Components in the Chassis” on page 101 .
Related
Documentation
• Overview of Installing the T4000 Router into a Rack on page 75
Copyright © 2013, Juniper Networks, Inc.
85
T4000 Router Hardware Guide
Tools Required to Install the T4000 Router Without a Mechanical Lift
To install the router, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• Flat-blade (–) screwdriver, number 1
• 7/16-in. (11 mm) socket wrench
• 3/8-in. nut driver
• ESD grounding wrist strap
Related
Documentation
• Overview of Installing a T4000 Router Without a Mechanical Lift on page 85
• Removing T4000 Components from the Chassis on page 86
• Installing the T4000 Chassis in a Rack or Cabinet Manually on page 98
• Reinstalling the T4000 Components in the Chassis on page 101
Removing T4000 Components from the Chassis
To make the router light enough to install manually, you must first remove most components from the chassis. These removal procedures are for the initial installation only, and assume that you have not connected any cables or power to the router.
86 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Figure 42: Components to Remove from the Rear of the T4000 Router
Fan tray
SCGs
Control board 0
Control board 1
SIBs
Power supply 0
Power supply 1
Copyright © 2013, Juniper Networks, Inc.
87
T4000 Router Hardware Guide
Figure 43: Components to Remove from the Front of the T4000 Router
Fan tray
FPCs
T Series
FANTRAY-T4000
88
Fan tray
FANTRA
Y-T4000
Remove the components first from the rear of the chassis ( Figure 42 on page 87 ), and then from the front ( Figure 43 on page 88 ):
1.
Removing the T4000 DC Power Supplies on page 89
2.
Removing the T4000 SIBs on page 90
3.
Removing the T4000 Control Boards on page 91
4.
Removing the T4000 SCGs on page 92
5.
Removing the T4000 Rear Fan Tray on page 93
6.
Removing the T4000 Front Cable Management System on page 94
7.
Removing the T4000 Front Fan Trays on page 95
8.
Removing the T4000 FPCs on page 97
Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Removing the T4000 DC Power Supplies
The power supplies are located at the rear of the chassis below the SIBs. Each six-input
DC power supply weighs approximately 39.7 lb (18.0 kg).
To remove the power supplies, starting with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
3.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
4.
Grasp the handle on the power supply faceplate, and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see Figure 44 on page 89 ).
5.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router.
6.
Repeat the procedure for the other power supply.
Figure 44: Removing a Six-Input DC Power Supply Before Installing the
Router
Copyright © 2013, Juniper Networks, Inc.
89
T4000 Router Hardware Guide
Removing the T4000 SIBs
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each SIB weighs approximately 7.1 lb (3.2 kg).
To remove the SIBs (see Figure 45 on page 91 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for each of the remaining SIBs.
90 Copyright © 2013, Juniper Networks, Inc.
Figure 45: Removing a SIB
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Removing the T4000 Control Boards
The router has one or two control boards, located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each LCC-CB weighs approximately 5 lb (2.3 kg).
To remove the control boards (see Figure 46 on page 92 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws on the ejector handles on both sides of the control board faceplate.
4.
Flip the ejector handles outward to unseat the control board.
5.
Grasp the ejector handles, and slide the control board about halfway out of the chassis.
6.
Place one hand underneath the control board to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for the second control board.
Copyright © 2013, Juniper Networks, Inc.
91
T4000 Router Hardware Guide
Figure 46: Removing a Control Board
Removing the T4000 SCGs
The router has one or two SCGs, located in the upper rear of the chassis, above the control boards and Routing Engines. Each SCG weighs approximately 1.9 lb (0.9 kg).
To remove the SCGs (see Figure 47 on page 93 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site..
3.
Loosen the captive screws on the edges of the SCG faceplate.
4.
Grasp the SCG by the handle on the faceplate, and slide it out of the chassis.
5.
Place the SCG on the antistatic mat.
6.
Repeat the procedure for the second SCG.
92 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Figure 47: Removing the SCGs
Removing the T4000 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray weighs about 10 lb (4.5 kg).
To remove the rear fan tray (see Figure 48 on page 94 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
4.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Copyright © 2013, Juniper Networks, Inc.
93
T4000 Router Hardware Guide
Figure 48: Removing the Rear Fan Tray
Removing the T4000 Front Cable Management System
The front cable management system is located below the FPC card cage. The cable management system weighs approximately 5 lb (2.3 kg).
To remove the front cable management system:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using a 3/8-in. nut driver, unscrew the nuts on the corners of the cable management system.
3.
Grasp the bottom of the cable management system, and pull it straight out from the studs on the front of the chassis.
94 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Removing the T4000 Front Fan Trays
The upper front fan tray is located above the FPC card cage, and the lower front fan tray is located below the air filter. Each front fan tray weighs about 20.4 lb (9.3 kg)
To remove the front fan trays (see Figure 49 on page 96 and Figure 50 on page 96 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the corners of the faceplate of one of the fan trays.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
4.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
5.
Repeat the procedure to remove the remaining front fan tray.
Copyright © 2013, Juniper Networks, Inc.
95
T4000 Router Hardware Guide
Figure 49: Removing an Upper Front Fan Tray
FANTRAY-T4000
T Series
FANTRAY-T4000
96
FANTRA
Y-T4000
Figure 50: Removing a Lower Front Fan Tray
FANTRAY-T4000
Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Removing the T4000 FPCs
The router holds up to eight FPCs, which are installed vertically in the front of the router.
An FPC with PICs installed can weigh up to 33.5 lb (15.1 kg).
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 9 lb (4.2 kg).
To remove an FPC (see Figure 51 on page 98 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Before removing the FPCs, record their location in the chassis so that you can reinstall each FPC in the correct slot.
4.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
5.
Grasp the handles, and slide the FPC straight out of the card cage halfway.
6.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 33.5 lb (15.1 kg)—as you slide the FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
7.
Repeat the procedure for each remaining FPC.
Copyright © 2013, Juniper Networks, Inc.
97
T4000 Router Hardware Guide
Figure 51: Removing an FPC
T-1600 FPC4
Related
Documentation
• Overview of Installing a T4000 Router Without a Mechanical Lift on page 85
• Installing the T4000 Chassis in a Rack or Cabinet Manually on page 98
• Reinstalling the T4000 Components in the Chassis on page 101
• Preventing T4000 Electrostatic Discharge Damage on page 296
Installing the T4000 Chassis in a Rack or Cabinet Manually
To install the router in the rack (see Figure 53 on page 101 ):
CAUTION: If you are installing two routers in one rack, install the lower one first. Installing a router in the upper position in a rack or cabinet requires a lift.
98 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
CAUTION: Before front-mounting the router in a rack, have a qualified technician verify that the rack is strong enough to support the router's weight and is adequately supported at the installation site.
CAUTION: Lifting the chassis and mounting it in a rack requires four people.
1.
For open-frame racks, ensure that the rack is in its permanent location and is secured to the building.
2.
Ensure that the installation site allows adequate clearance for both airflow and maintenance.
3.
Attach the installation handle by tightening the captive screws of the handle into the holes previously occupied by the captive screws of the power supplies (see
Figure 52 on page 99 ). Tighten the screws, using a Phillips (+) screwdriver, number 2.
Figure 52: Attaching the Installation Handle
CAUTION: Do not lift the router using the installation handle or the handles on the sides of the chassis. Use these handles only to help position the router.
4.
Position the router in front of the rack or cabinet, centering it in front of the mounting shelves. Use a pallet jack if one is available.
5.
With two people in the front and two people in the back, hold onto the bottom of the chassis, and carefully lift it onto the mounting shelves.
Copyright © 2013, Juniper Networks, Inc.
99
T4000 Router Hardware Guide
WARNING: To prevent injury, keep your back straight and lift with your legs, not your back. Avoid twisting your body as you lift. Balance the load evenly, and be sure that your footing is solid.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while two people push on the front-mounting flanges, slide the router onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
8.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
100 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Figure 53: Installing the Router in the Rack
NOTE: For an illustration of the mounting hardware required for an open-frame rack, see “Installing the T4000 Mounting Hardware for an
Open-Frame Rack” on page 70 .
Related
Documentation
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Overview of Installing a T4000 Router Without a Mechanical Lift on page 85
• Removing T4000 Components from the Chassis on page 86
• Reinstalling the T4000 Components in the Chassis on page 101
• Preventing T4000 Electrostatic Discharge Damage on page 296
Reinstalling the T4000 Components in the Chassis
After the router is installed in the rack, you reinstall the removed components before cabling, booting, and configuring the router.
Copyright © 2013, Juniper Networks, Inc.
101
T4000 Router Hardware Guide
The procedures describe how to reinstall components in the chassis, first in the rear and then in the front:
1.
Reinstalling the Rear Fan Tray on page 102
2.
Reinstalling the T4000 SCGs on page 103
3.
Reinstalling the T4000 Control Boards on page 104
4.
Reinstalling the T4000 SIBs on page 105
5.
Reinstalling the Power Supplies on page 105
6.
Reinstalling the FPCs on page 106
7.
Reinstalling T4000 Front Fan Trays on page 107
8.
Reinstalling the T4000 Front Cable Management System on page 108
Reinstalling the Rear Fan Tray
To install a replacement rear fan tray (see Figure 54 on page 103 ):
1.
Grasp the fan tray by its handles, and insert it straight into the chassis.
2.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
102 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Figure 54: Reinstalling the Rear Fan Tray
Reinstalling the T4000 SCGs
To reinstall the SCGs (see Figure 55 on page 104 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the SCG with the guides in the SCG slot.
3.
Grasp the SCG by its handle, and slide it straight into the chassis until it contacts the midplane.
4.
Tighten the captive screws on the corners of the SCG faceplate.
5.
Repeat the procedure to reinstall the remaining SCG.
Copyright © 2013, Juniper Networks, Inc.
103
T4000 Router Hardware Guide
Figure 55: Reinstalling an SCG
Reinstalling the T4000 Control Boards
To reinstall the control boards (see Figure 56 on page 104 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the control boards with the guides inside the chassis.
3.
Slide the control boards into the chassis, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles and press them inward to seat the control board.
5.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
6.
Repeat the procedure to reinstall the remaining control board.
Figure 56: Reinstalling an LCC-CB
104 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Reinstalling the T4000 SIBs
To reinstall the SIBs (see Figure 57 on page 105 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB faceplate.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the SIB.
6.
Tighten the captive screws on the ejector handles.
7.
Repeat the procedure for each of the remaining SIBs.
Figure 57: Reinstalling a T4000 SIB
Reinstalling the Power Supplies
Reinstall the lower power supply first, then the upper power supply. To reinstall the DC power supplies (see Figure 58 on page 106 ):
1.
Using both hands, slide the power supply into the chassis until you feel resistance.
2.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
Copyright © 2013, Juniper Networks, Inc.
105
T4000 Router Hardware Guide
3.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
4.
Repeat the procedure for the upper power supply.
Figure 58: Reinstalling a Six-Input DC Power Supply
Reinstalling the FPCs
To reinstall FPCs (see Figure 59 on page 107 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using the list you created when you removed the FPCs, locate the slot in the FPC card cage in which you plan to install the FPC.
3.
Lift the FPC into place and carefully align first the bottom, then the top of the FPC with the guides inside the card cage. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
4.
Slide the FPC all the way into the card cage until you feel resistance.
5.
Starting with the ejector handles on the FPC faceplate nearly horizontal, simultaneously turn both ejector handles clockwise to seat the FPC.
6.
Repeat the procedure to reinstall each remaining FPC.
106 Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Installing the T4000 Router Without a Mechanical Lift
Figure 59: Reinstalling an FPC
T-1600 FPC4
Reinstalling T4000 Front Fan Trays
To reinstall the front fan trays (see Figure 60 on page 108 and Figure 61 on page 108 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Grasp one of the fan trays by its handles, and insert it straight into the chassis.
3.
Tighten the captive screw on each side of the fan tray faceplate to secure it in the chassis.
4.
Repeat the procedure to reinstall the remaining fan tray.
Copyright © 2013, Juniper Networks, Inc.
107
T4000 Router Hardware Guide
Figure 60: Reinstalling an Upper Front Fan Tray
T Series
FANTRAY-T4000
FANTRAY-T4000
Figure 61: Reinstalling a Lower Front Fan Tray
FANTRAY-T4000
Reinstalling the T4000 Front Cable Management System
To reinstall the front cable management system:
1.
Position the front cable management system on the studs on the lower front of the chassis.
2.
Insert the nuts through the holes in the cable management system onto the studs on the chassis.
3.
Using a 3/8-in. nut driver, tighten the nuts securely.
Related
Documentation
• Overview of Installing a T4000 Router Without a Mechanical Lift on page 85
• Removing T4000 Components from the Chassis on page 86
• Preventing T4000 Electrostatic Discharge Damage on page 296
108 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 11
Grounding the T4000 Router
• Overview of Grounding the T4000 Router on page 109
• Tools and Parts Required to Ground the T4000 Router on page 109
• Connecting the T4000 Grounding Cable on page 110
Overview of Grounding the T4000 Router
To ground the router, see the following topics:
1.
Tools and Parts Required to Ground the T4000 Router on page 109
2.
Connecting the T4000 Grounding Cable on page 110
Related
Documentation
• Overview of Installing the T4000 Router on page 55
Tools and Parts Required to Ground the T4000 Router
• Grounding cable (which you must provide)
• Grounding lug (provided with the router)
Figure 62: Grounding Lug
• M6 screws or UNC 1/4-20 screws
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
• Overview of Grounding the T4000 Router on page 109
• Connecting the T4000 Grounding Cable on page 110
Copyright © 2013, Juniper Networks, Inc.
109
T4000 Router Hardware Guide
Connecting the T4000 Grounding Cable
You ground the router by connecting a grounding cable to earth ground and then attaching it to the chassis grounding points with two screws. You must provide the grounding cable
(a cable lug is supplied with the router). To connect the grounding cable (see
Figure 63 on page 110 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Make sure that grounding surfaces are clean and brought to a bright finish before grounding connections are made.
3.
Connect the grounding cable to a proper earth ground.
4.
Verify that a licensed electrician has attached the cable lug provided with the router to the grounding cable.
5.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
6.
Place the grounding cable lug over the grounding points. The left pair is sized for M6 screws, and the right pair is sized for UNC 1/4-20 screws.
7.
Secure the grounding cable lug to the grounding points, first with the washers, then with the screws.
8.
Verify that the grounding cabling is correct, that the grounding cable does not touch or block access to router components, and that it does not drape where people could trip on it.
Figure 63: Connecting the Grounding Cable
110
Grounding points
(on chassis)
Related
Documentation
• Overview of Grounding the T4000 Router on page 109
• Tools and Parts Required to Ground the T4000 Router on page 109
• T4000 Chassis Grounding Cable and Lug Specifications on page 335
Copyright © 2013, Juniper Networks, Inc.
CHAPTER 12
Connecting the T4000 Router to External
Devices
• Overview of Connecting the T4000 Router to External Devices on page 111
• Tools and Parts Required to Connect the T4000 Router to External Devices on page 112
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
• Connecting the T4000 Router to an External Alarm-Reporting Device on page 114
• Connecting the T4000 Router to an External Clocking Device on page 115
• Connecting PIC Cables to the T4000 Router on page 116
• Connecting the T4000 Router to a Management Ethernet Device on page 118
Overview of Connecting the T4000 Router to External Devices
After you have grounded the T4000 Core Router, you can connect the following external devices:
• An external console or auxiliary device to the CONSOLE ports on the Connector Interface
Panel (CIP).
See “Connecting the T4000 Router to a Management Console or Auxiliary Device” on page 112 .
• A laptop, modem, or other auxiliary device to the AUXILIARY ports on the CIP.
See “Connecting the T4000 Router to a Management Console or Auxiliary Device” on page 112 .
• A management network to the ETHERNET ports on the CIP.
See “Connecting the T4000 Router to a Management Ethernet Device” on page 118 .
• An external alarm-reporting device to the alarm relay contacts on the CIP.
See “Connecting the T4000 Router to an External Alarm-Reporting Device” on page 114 .
• An external clocking device to the EXTERNAL CLOCK INPUTS on the SONET Clock
Generator with RJ-48 ports.
See “Connecting the T4000 Router to an External Clocking Device” on page 115 .
Copyright © 2013, Juniper Networks, Inc.
111
T4000 Router Hardware Guide
NOTE: The external clock inputs on the SCG with DB-9 ports are not supported.
• A network connection to the ports on the PICs.
See “Connecting PIC Cables to the T4000 Router” on page 116 .
Related
Documentation
• Overview of Installing the T4000 Router on page 55
Tools and Parts Required to Connect the T4000 Router to External Devices
To connect the router to external devices, you need the following tools:
• Phillips (+) screwdrivers, numbers 1 and 2
• 2.5-mm flat-blade (-) screwdriver
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
• Overview of Connecting the T4000 Router to External Devices on page 111
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
• Connecting the T4000 Router to an External Alarm-Reporting Device on page 114
• Connecting the T4000 Router to an External Clocking Device on page 115
• Connecting PIC Cables to the T4000 Router on page 116
Connecting the T4000 Router to a Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the appropriate CONSOLE port on the CIP. To use a laptop, modem, or other auxiliary device, connect it to the appropriate AUXILIARY port on the CIP. Both ports accept an RS-232
(EIA-232) serial cable with a DB-9 female connector. One DB-9/DB-9 cable is provided with the router. To connect a device to the CONSOLE port, and another device to the
AUXILIARY port, you must supply another cable.
To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Connect one end (shown in Figure 64 on page 113 ) of a serial cable with a DB-9 female connector to the appropriate CONSOLE or AUXILIARY port (see Figure 65 on page 114 ).
The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower
Routing Engine slot ( RE1 ).
112 Copyright © 2013, Juniper Networks, Inc.
Chapter 12: Connecting the T4000 Router to External Devices
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
• Parity—N
• Data bits—8
• Stop bits—1
• Flow control—none
4.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
5.
Attach the other end of the cable to the console or auxiliary device.
Figure 64: Console and Auxiliary Serial Port Connector
Copyright © 2013, Juniper Networks, Inc.
113
T4000 Router Hardware Guide
Figure 65: Console and Auxiliary Ports on the CIP
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Overview of Connecting the T4000 Router to External Devices on page 111
Connecting the T4000 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED ALARM and YELLOW ALARM relay contacts on the CIP. A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28 AWG and 14 AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
114 Copyright © 2013, Juniper Networks, Inc.
Chapter 12: Connecting the T4000 Router to External Devices
To connect an external device to an alarm relay contact:
1.
Prepare the required length of wire with gauge between 28 AWG and 14 AWG (0.08
and 2.08 mm
2
).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to loosen the small screws on its side. With the small screws on its side facing left, insert wires into the slots in the front of the block based on the wiring for the external device. Tighten the screws to secure the wire.
4.
Orient the terminal block according to the labels to the left of the appropriate relay contact ( NC means “normally closed, C means “common,” and ( NO means “normally open”).
5.
Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
6.
Attach the other end of the wires to the external device.
If attaching a reporting device for the other kind of alarm, repeat the procedure.
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Overview of Connecting the T4000 Router to External Devices on page 111
Connecting the T4000 Router to an External Clocking Device
To connect the router to one or two external clocking devices, connect a cable with RJ-48 connectors to one of the EXTERNAL CLOCK INPUTS ports on the SCG.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Plug one end of the cable into the appropriate EXTERNAL CLOCK INPUTS port on the
SCG.
3.
Plug the other end of the cable into the T1 external clocking device.
4.
Repeat the procedure for the other EXTERNAL CLOCK INPUTS port on the SCG.
5.
Verify that the LINK LED for each port is lit steadily green.
6.
.
Configure the port. See the synchronization statement for M Series and T Series in the
7.
Issue the show chassis synchronization command to check the status of the port.
user@host> show chassis synchronization user@host> show chassis synchronization
Clock Synchronization Status :
Clock module on SCG 0
Current state : master
Current clock state : locked to external-a
Copyright © 2013, Juniper Networks, Inc.
115
T4000 Router Hardware Guide
Selected for : 2 hours, 28 minutes, 4 seconds
Selected since : 2006-02-17 01:12:58 PST
Configured sources
Source Priority Deviation Last deviation Status
(in ppm) (in ppm)
external-a primary measuring -0.10 in-use
external-b secondary -0.10 -0.10 qualified
Clock Synchronization Status :
Clock module on SCG 1
Current state : backup
Current clock state : locked to master SCG
Selected for : 19 hours, 49 minutes, 14 seconds
Selected since : 2006-02-16 07:51:48 PST
Configured sources
Source Priority Deviation Last deviation Status
(in ppm) (in ppm)
external-a primary -0.25 -0.25 qualified
external-b secondary -0.25 -0.25 qualified
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Overview of Connecting the T4000 Router to External Devices on page 111
Connecting PIC Cables to the T4000 Router
The router supports PICs that use various kinds of network cable, including multimode and single-mode fiber-optic cable.
You connect PICs to the network by plugging in network cable. To connect cable to the
PICs (see Figure 66 on page 117 , which shows a fiber-optic PIC):
1.
Have ready a length of the type of cable used by the PIC. For information about the type of cable used by each PIC, see the T4000 Interface Module Reference . For cable specifications, see the “Network Cable and Transceiver Overview for T Series Routers” on page 345 .
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight
116 Copyright © 2013, Juniper Networks, Inc.
Chapter 12: Connecting the T4000 Router to External Devices as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop.
Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Figure 66: Attaching a Cable to a PIC
PIC
Fiber-optic cable
Related
Documentation
• T4000 PIC Description on page 42
• Overview of Connecting the T4000 Router to External Devices on page 111
Copyright © 2013, Juniper Networks, Inc.
117
T4000 Router Hardware Guide
Connecting the T4000 Router to a Management Ethernet Device
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet with RJ-45 connectors to the ETHERNET port on the CIP. One cable is provided with the router.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Turn off the power to the management device.
3.
Plug one end of the Ethernet cable ( Figure 67 on page 118 shows the connector) into the appropriate ETHERNET port on the CIP (see Figure 68 on page 119 ). The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot ( RE1 ).
4.
Plug the other end of the cable into the network device.
Figure 67: Routing Engine Ethernet Cable Connector
118 Copyright © 2013, Juniper Networks, Inc.
Chapter 12: Connecting the T4000 Router to External Devices
Figure 68: ETHERNET Port on the CIP
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Overview of Connecting the T4000 Router to External Devices on page 111
Copyright © 2013, Juniper Networks, Inc.
119
T4000 Router Hardware Guide
120 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 13
Providing Power to the T4000 Router
• Tools and Parts Required to Provide Power to the T4000 Router on page 121
• Connecting Power to the T4000 Router on page 121
• Powering On the T4000 Router on page 141
• Powering Off the T4000 Router on page 142
Tools and Parts Required to Provide Power to the T4000 Router
To connect the router to power, you need the following tools and parts:
• DC-powered routers: 7/16-in. (11 mm) hexagonal-head external drive nut driver, with a torque range between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm), for tightening nuts to terminal studs on each power supply on a DC-powered router.
• Torque-controlled tool.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 in-lb (5.0 Nm).
• DC power cables and lugs. See “T4000 DC Power Cable and Lugs Specifications” on page 341 .
Related
Documentation
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
Connecting Power to the T4000 Router
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
Copyright © 2013, Juniper Networks, Inc.
121
T4000 Router Hardware Guide
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
Connecting DC Power to the T4000 Router (Six 60-A Inputs)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
NOTE: We recommend that the positive (+) DC source power cables for the
RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables for the –48 V (input) terminals.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
To connect DC source power cables to the router, follow this procedure for each DC power supply:
1.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
122 Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
3.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
7.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
8.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Figure 69: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Attach the negative (–) DC source power cable lugs INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 to the –48 V (input) terminals on the right. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 70: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
INPUT 3, and INPUT 4
Copyright © 2013, Juniper Networks, Inc.
123
T4000 Router Hardware Guide
9.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
10.
Route the negative (–) DC source power cables for INPUT 2 and INPUT 5 through the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the –48 V (input) terminals on the right. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 71: Connecting Negative (–) DC Power Cables to INPUT 2 and
INPUT 5
124
11.
Route the positive (+) DC source power cables for RTN 2 and RTN 5 over the middle cable restraint. The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs RTN 2 and RTN 5 to the RTN
(return) terminals on the left. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
12.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 2 , INPUT 5 , RTN 2 , and RTN 5 in place.
13.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 .
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN 0 , RTN 1 , RTN 3 , and
RTN 4 terminals on the left. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
14.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 72: Connecting Positive (+) DC Power Cables to RTN 2, RTN 5,
RTN 0, RTN 1, RTN 3, and RTN 4
15.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
16.
Replace the clear plastic cover over the terminal studs on the faceplate.
Related
Documentation
• Tools and Parts Required to Provide Power to the T4000 Router on page 121
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Powering On the T4000 Router on page 141
• Configuring DC Power on a T4000 Router on page 148
• Troubleshooting the T4000 Power System on page 204
• T4000 DC Power Electrical Safety Guidelines on page 320
• T4000 DC Power Cable and Lugs Specifications on page 341
Copyright © 2013, Juniper Networks, Inc.
125
T4000 Router Hardware Guide
Connecting DC Power to the T4000 Router (Five 60-A Inputs)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: Do not use a terminal jumper for 60-A DC power cables. Using a terminal jumper is not supported for this procedure. Doing so will cause a short across the inputs and trip your external circuit breaker.
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
126 Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
To connect five 60-A DC source power cables to the router, follow this procedure for each DC power supply:
1.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
3.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
7.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
8.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 , over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 ,
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals on the right: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 73: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Copyright © 2013, Juniper Networks, Inc.
127
T4000 Router Hardware Guide
Figure 74: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
INPUT 3, and INPUT 4
9.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
10.
Route the negative (–) DC source power cables for INPUT 2 , through the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT
2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cable in the location as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the INPUT 2 –48 V (input) terminal on the right. Secure the cable lug to the terminal studs, first with the washer, then with the nut. Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between
23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 75: Connecting Negative (–) DC Power Cable to INPUT 2
128
11.
Route the positive (+) DC source power cables for RTN 2 over the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT
2 , RTN 2 , RTN 5 , and INPUT 5 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
Attach the positive (+) DC source power cable lug to the RTN 2 (return) terminal on the left. Secure the cable lug to the terminal stud, first with the washer, then with the nut. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6
Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
12.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 2 and RTN 2 in place.
13.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom RTN 0 , RTN 1 , RTN 3 , and RTN 4 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN terminals on the left:
RTN 0 , RTN 1 , RTN 3 , and RTN 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
14.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 76: Connecting Positive (+) DC Power Cable to RTN 2, RTN 0, RTN 1,
RTN 3, RTN 4
15.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
16.
Replace the clear plastic cover over the terminal studs on the faceplate.
Related
Documentation
• Tools and Parts Required to Provide Power to the T4000 Router on page 121
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Powering On the T4000 Router on page 141
Copyright © 2013, Juniper Networks, Inc.
129
T4000 Router Hardware Guide
• Configuring DC Power on a T4000 Router on page 148
• T4000 DC Power Electrical Safety Guidelines on page 320
• T4000 DC Power Cable and Lugs Specifications on page 341
Connecting DC Power to the T4000 Router (Four 60-A Inputs)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: Do not use a terminal jumper for 60-A DC power cables. Using a terminal jumper is not supported for this procedure. Doing so will cause a short across the inputs and trip your external circuit breaker.
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
130 Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
To connect four 60-A DC source power cables to the router, follow this procedure for each DC power supply:
1.
Check your planned hardware configuration and verify that four 60-A DC source power cables will provide sufficient power. See the DC power requirements for your router for more information.
2.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
3.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
4.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
5.
Switch the power switch on the power supply faceplate to the standby position.
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
7.
Remove the nut and washer from each power terminal stud to be connected ( INPUT
0 , INPUT 1 , INPUT 3 , INPUT 4 , and RTN 0 , RTN 1 , RTN 3 , and RTN 4 ). If no washers and nuts are already installed, they should be in the accessory box.
8.
Remove the captive screws on the smallest cable restraint on the right edge of the power supply faceplate, and the largest cable restraint to the left (using a Phillips (+) screwdriver, number 2).
9.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 , over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals on the right: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 77: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Copyright © 2013, Juniper Networks, Inc.
131
T4000 Router Hardware Guide
Figure 78: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT
1. INPUT 3, and INPUT 4
10.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
11.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the RTN terminals on the left:
RTN 0 , RTN 1 , RTN 3 , and RTN 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
12.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 79: Connecting Positive (+) DC Power Cables to RTN 0, RTN 1, RTN
3, and RTN 4
132
13.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
Related
Documentation
• Tools and Parts Required to Provide Power to the T4000 Router on page 121
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Powering On the T4000 Router on page 141
• Configuring DC Power on a T4000 Router on page 148
• T4000 DC Power Requirements on page 338
• T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 340
• T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 340
• Troubleshooting the T4000 Power System on page 204
• T4000 DC Power Electrical Safety Guidelines on page 320
• T4000 DC Power Cable and Lugs Specifications on page 341
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A Inputs)
You connect DC power to the router by using a terminal jumper to attach one DC power cable from the DC power source to two terminal studs on the power supply faceplate.
Use the terminal jumper kit (model number PWR-T-BUS-BAR-S) to perform this procedure. The terminal jumper kit contains the terminal jumpers and the new clear plastic cover required to accommodate the terminal jumpers. Six terminal jumpers are required for each power supply. You must provide power cables (the cable lugs are supplied with the router).
CAUTION: When using a terminal jumper for this procedure, terminate only a single DC power cable to the two input terminals using the terminal jumper as shown in Figure 83 on page 137 and Figure 84 on page 138 . Do not connect two DC power cables using a terminal jumper to two inputs as shown in
Figure 80 on page 134 . Connecting two DC power cables using a terminal jumper to two inputs will cause a short across the inputs and trip your external circuit breaker.
Copyright © 2013, Juniper Networks, Inc.
133
T4000 Router Hardware Guide
Figure 80: Incorrect Cable Connection to INPUT 1
134
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
To connect 80-A DC source power cables to six inputs using a terminal jumper, follow this procedure for each DC power supply:
1.
Check your planned hardware configuration, and verify that three 80-A DC source power cables will provide sufficient power. See the DC power requirements for your router for more information.
2.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
3.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
4.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
5.
Switch the power switch on the power supply faceplate to the standby position.
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
NOTE: You will replace this cover with the new cover provided in the terminal jumper kit (model number PWR-T-BUS-BAR-S). The new cover is labeled 2 in Figure 86 on page 140 .
7.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
8.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
9.
Place one terminal jumper over the negative (–) DC INPUT 0 and INPUT 1 terminals on the right.
NOTE: The terminal jumpers are located in the terminal jumper kit (model number PWR-T-BUS-BAR-S).
Figure 81: Terminal Jumper
10.
Place a washer, and then a nut on the negative (–) DC INPUT 0 terminal.
Copyright © 2013, Juniper Networks, Inc.
135
T4000 Router Hardware Guide
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 82: Connecting DC Power Cables
Jumper
Nut
Locking washer
Terminal studs
Cable lug
136
Grounding points
(on chassis)
11.
Route the negative (–) DC source power cable for INPUT 1 over the smallest cable restraint on the far right.
NOTE: The smallest cable restraint is marked as follows from top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . You must route the cables in the locations as marked to be able to install the new clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lug to the –48 V (input) INPUT 1 terminal on the right. Secure the cable lug to the terminal stud, first with the washer, then with the nut.
12.
Place one terminal jumper over the negative (–) DC INPUT 2 and INPUT 3 input terminals on the right.
13.
Place a washer, and then a nut on the negative (–) DC INPUT 2 terminal.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
14.
Route the negative (–) DC source power cable for INPUT 3 over the smallest cable restraint on the far right.
Attach the negative (–) DC source power cable lug to the –48 V (input) INPUT 3 terminal on the right. Secure the cable lug to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
Figure 83: Negative (–) DC Power Cables Connected to INPUT 1 and
INPUT 3
15.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 1 and INPUT 3 in place.
16.
Place one terminal jumper over the negative (–) DC INPUT 4 and INPUT 5 input terminals on the right.
17.
Place a washer, and then a nut on the negative (–) DC INPUT 4 terminal.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
18.
Route the negative (–) DC source power cable for INPUT 5 through the middle cable restraint.
NOTE: The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 . You must route the cable in the location as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lug to the –48 V (input) INPUT 5 terminal on the right. Secure the cable lug to the terminal studs, first with the washers, then with the nuts.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Copyright © 2013, Juniper Networks, Inc.
137
T4000 Router Hardware Guide
Figure 84: Connecting Negative (–) DC Power Cable to INPUT 5
138
19.
Place one terminal jumper over the positive (+) DC RTN 4 and RTN 5 input terminals on the left
20.
Place a washer, and then a nut on RTN 4 .
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
21.
Route the positive (+) DC source power cable for the RTN 5 input terminal through the middle cable restraint.
NOTE: The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 . You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lug to the RTN 5 RTN (return) terminal on the left. Secure the cable lug to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
22.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 5 and RTN 5 in place.
23.
Place one terminal jumper over RTN 0 and RTN 1 .
24.
Place a washer, and then a nut on RTN 0 .
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
25.
Route the positive (+) DC source power cable for RTN 1 over the largest cable restraint on the left.
NOTE: The large left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 . You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
Attach the positive (+) DC source power cable lugs to the RTN 1 terminal on the left.
Secure the cable lugs to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
26.
Place terminal jumper over RTN 2 and RTN 3 .
27.
Place a washer, and then a nut on RTN 2 .
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
28.
Route the positive (+) DC source power cable for RTN 3 over the largest cable restraint on the left.
NOTE: The large left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 . You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lug to the RTN 3 terminal on the left.
Secure the cable lug to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
29.
Replace the large left cable restraint, and tighten the captive screw to hold the power cables for RTN 1 and RTN 3 in place.
Figure 85: Positive (+) DC Power Cables Connected to RTN 1, RTN 3, and
RTN 5
30.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
31.
Install the clear plastic terminal jumper cover (labeled 2 in Figure 86 on page 140 ) located in the terminal jumper kit (model number PWR-T-BUS-BAR-S) to protect the terminal studs on the faceplate.
Copyright © 2013, Juniper Networks, Inc.
139
T4000 Router Hardware Guide
NOTE: You must use the terminal jumper cover provided in the terminal jumper kit (model number PWR-T-BUS-BAR-S) to ensure there is no access to the terminal jumpers and for proper cable alignment. The terminal jumper cover (labeled 2 in Figure 86 on page 140 ) has three cable openings and is longer than the original clear plastic cover (labeled 1 in
Figure 86 on page 140 ) that has six cable openings.
Figure 86: Power Supply Covers
140
1 2
Related
Documentation
• Tools and Parts Required to Provide Power to the T4000 Router on page 121
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Powering On the T4000 Router on page 141
• Configuring DC Power on a T4000 Router on page 148
• Troubleshooting the T4000 Power System on page 204
• T4000 DC Power Requirements on page 338
• T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 340
• T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 340
• T4000 DC Power Electrical Safety Guidelines on page 320
• T4000 DC Power Cable and Lugs Specifications on page 341
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Providing Power to the T4000 Router
Powering On the T4000 Router
To power on the DC-powered T4000 router:
1.
Verify that the power supplies are fully inserted in the chassis and that the captive screws on their faceplates are tightened.
2.
Verify that the source power cables are connected to the appropriate terminal: the positive (+) source cable to the return terminal (labeled RTN ) and the negative (–) source cable to the input terminal (labeled –48V ).
3.
Verify that an external management device is connected to one of the Routing Engine ports on the CIP ( AUXILIARY , CONSOLE , or ETHERNET ).
NOTE: If you are powering on the router for the first time, the AUXILIARY and ETHERNET ports do not function until after the initial configuration procedure.
4.
Turn on the power to the external management device.
5.
Switch on the dedicated customer site circuit breakers to provide power to the DC power cables. Follow your site’s procedures.
6.
Verify that the INPUT PRESENT LED for each input on the DC power supply faceplate is lit steadily green, indicating that the inputs are receiving power.
7.
Switch the power switch on the power supply to the ON position ( — ). The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
8.
Verify that the DC OK LED on the DC power supply faceplate is lit steadily, indicating that power supply is correctly installed and functioning properly.
9.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the router has booted properly.
10.
Repeat the procedure for the other power supply.
Copyright © 2013, Juniper Networks, Inc.
141
T4000 Router Hardware Guide
Figure 87: Six-Input DC Power Supply
Related
Documentation
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Powering Off the T4000 Router on page 142
Powering Off the T4000 Router
To power off a T4000 router:
1.
On the external management device connected to the Routing Engine, issue the request system halt operational mode command. The command shuts down both
Routing Engines cleanly, so their state information is preserved. (If the router contains only one Routing Engine, issue the request system halt command.)
2.
user@host> request system halt both-routing-engines
Wait until a message appears on the console confirming that the operating system has halted.
Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from root@section2 ***
System going down IMMEDIATELY
Terminated
...
syncing disks... 11 8 done
The operating system has halted.
Please press any key to reboot.
3.
Switch off the external customer site circuit breakers to the power supplies.
142 Copyright © 2013, Juniper Networks, Inc.
Related
Documentation
• Powering On the T4000 Router on page 141
• request system halt
Chapter 13: Providing Power to the T4000 Router
Copyright © 2013, Juniper Networks, Inc.
143
T4000 Router Hardware Guide
144 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 14
Configuring Junos OS
• Initially Configuring the T4000 Router on page 145
• Configuring DC Power on a T4000 Router on page 148
Initially Configuring the T4000 Router
These procedures connect a router to the network but do not enable it to forward traffic.
For complete information about enabling the router to forward traffic, including examples, see the Junos OS configuration guides.
You configure the router by issuing Junos OS command-line interface (CLI) commands, either on a console device attached to the CONSOLE port, or over a telnet connection to a network connected to the ETHERNET port.
NOTE: These procedures enable you to use the ETHERNET management port. For the initial configuration, use a device attached to the CONSOLE port.
1.
Preparing to Configure the Router on page 145
2.
Entering Configuration Mode on page 146
3.
Configuring User Accounts and Passwords on page 146
4.
Configuring System Attributes on page 146
5.
Committing the Configuration on page 147
Preparing to Configure the Router
Gather the following information before configuring the router:
• Name the router will use on the network
• Domain name the router will use
• IP address and prefix length information for the Ethernet interface
• IP address of a default router
• IP address of a DNS server
• Password for the root user
Copyright © 2013, Juniper Networks, Inc.
145
T4000 Router Hardware Guide
Entering Configuration Mode
1.
Verify that the network device is powered on.
2.
Log in as the root user. There is no password.
Amnesiac <ttyd0> login: root
3.
Start the CLI.
root@% cli root>
4.
Enter configuration mode.
root> configure
Entering configuration mode.
[edit] root#
Configuring User Accounts and Passwords
For information about using an encrypted password or an SSH public key string (DSA or
RSA), see authentication .
1.
Add a password to the root administration user account. Enter a clear-text password.
[edit] root# set system root-authentication plain-text-password
New password: password
Retype new password: password
2.
Create a management console user account.
[edit] root# set system login user user-name authentication plain-text-password
New Password: password
Retype new password: password
3.
Set the user account class to super-user .
[edit] root@# set system login user user-name class super-user
Configuring System Attributes
For more information on configuring the backup routing and static routes, see the Junos
OS Administration Library for Routing Devices .
1.
Configure the name of the router. If the name includes spaces, enclose the name in quotation marks (“ ”).
[edit] root@host# set system host-name host-name
146 Copyright © 2013, Juniper Networks, Inc.
Chapter 14: Configuring Junos OS
NOTE: The DNS server does not use the hostname to resolve to the correct
IP address. This hostname is used only to display the name of the routing engine in the CLI. For example, this hostname shows on the command-line prompt when the user is logged on to the CLI:
[edit]
user-name@host-name>
2.
Configure the IP address of the DNS server.
[edit] root# set system name-server address
3.
Configure the router’s domain name.
[edit] root# set system domain-name domain-name
4.
Configure the IP address and prefix length for the router’s management Ethernet interface.
NOTE: The RE-C1800 Routing Engine ( RE-DUO-1800 ) does not support the fxp0 management Ethernet interface or the fxp1 and fxp2 internal
Ethernet interfaces. Use the em0 interface for the RE-C1800 Routing
Engine.
[edit] root# set interfaces em0 unit 0 family inet address address/prefix-length
5.
Configure the IP address of a backup routing engine. The backup routing engine is used while the local router is booting and if the routing process fails to start. After the routing process starts, the backup routing engine address is removed from the local routing and forwarding tables.
[edit] root# set system backup-router address
6.
(Optional) Configure the static routes to remote subnets with access to the management port. Access to the management port is limited to the local subnet. To access the management port from a remote subnet, you must add a static route to that subnet within the routing table.
[edit] root# set routing-options static route remote-subnet next-hop destination-IP retain no-readvertise
7.
Configure the telnet service at the [edit system services] hierarchy level.
[edit] set system services telnet
Committing the Configuration
1.
Display the configuration to verify that it is correct.
Copyright © 2013, Juniper Networks, Inc.
147
T4000 Router Hardware Guide
[edit] root# show system { host-name host-name; domain-name domain-name; backup-router address; root-authentication {
authentication-method (password | public-key);
} name-server {
address;
}
} interfaces { fxp0 { unit 0 { family inet { address address/prefix-length;
}
}
}
}
2.
Commit the configuration to activate it on the router.
[edit] root# commit
3.
Optionally, configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them on the router.
[edit] root# commit
4.
When you have finished configuring the router, exit configuration mode.
[edit] root# exit
Related
Documentation
• Powering On the T4000 Router on page 141
• T4000 Router Description on page 3
Configuring DC Power on a T4000 Router
After you have connected the DC power and initially configured the router, you must configure the number of input feeds if you connected fewer than six cables to the six-input
DC power supply. You must also configure the input current for the DC power supply if you connected three 80-A cables to the six-input DC power supply.
148 Copyright © 2013, Juniper Networks, Inc.
Chapter 14: Configuring Junos OS
For more information about configuring the DC power supply and the commands used in the procedures, see the T4000 Power Management Overview in the Junos OS
Administration Library for Routing Devices .
• Configuring DC Power on a T4000 Router (Five 60-A Cables on a Six-Input DC Power
Supply) on page 149
• Configuring DC Power on a T4000 (Four 60-A Cables on a Six-Input DC Power
Supply) on page 149
• Configuring DC Power on a T4000 (Three 80-A Cables on a Six-Input DC Power
Supply) on page 150
Configuring DC Power on a T4000 Router (Five 60-A Cables on a Six-Input DC Power Supply)
When you connect five cables on a six-input DC power supply, you must specify the number of input feeds connected in the software. If the number of physical input feeds receiving power does not match the number of configured input feeds, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that five DC power cables are connected.
[edit] user@host# set chassis pem feeds 5
NOTE: The default number of input feeds is 6.
2.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 5;
}
3.
Commit the configuration to activate it on the router, and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
Configuring DC Power on a T4000 (Four 60-A Cables on a Six-Input DC Power Supply)
When you connect four cables on a six-input DC power supply, you must specify the number of input feeds connected in the software. If the number of physical input feeds receiving power does not match the number of configured input feeds, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that four DC power cables are connected.
[edit]
Copyright © 2013, Juniper Networks, Inc.
149
T4000 Router Hardware Guide user@host# set chassis pem feeds 4
NOTE: The default number of input feeds is 6.
2.
(Optional) If the power has been underprovisioned for your configuration, some FPCs might not be brought online if the available power capacity is exceeded. When you reboot the router, FPCs are brought online based on the default setting of the fru-poweron-sequence command. You can use the fru-poweron-sequence command to change the default order in which FPCs are brought online when the router is rebooted. The default sequence is the numerical order of the FPC slots (0 through 7).
[edit] user@host# set chassis fru-poweron-sequence fru-poweron-sequence
3.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 4;
}
4.
Commit the configuration to activate it on the router, and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
Configuring DC Power on a T4000 (Three 80-A Cables on a Six-Input DC Power Supply)
When you connect three 80-A DC power cables to six inputs using terminal jumpers to each power supply, you must specify the input current in the software. In addition, you must also indicate that six input feeds are used. If the number of physical input feeds receiving power does not match the number of configured inputs, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that six feeds are used to connect the three 80-A DC power cables by means of terminal jumpers.
[edit] user@host# set chassis pem feeds 6
NOTE: The default number of input feeds is 6.
2.
Configure the input current to indicate that 40-A is used to provide input current. Each
80-A DC power cable connects to two inputs by means of a terminal jumper, with each input receiving approximately 40 amps.
[edit] user@host# set chassis pem input-current 40
150 Copyright © 2013, Juniper Networks, Inc.
Chapter 14: Configuring Junos OS
NOTE: The default input current is 60-A.
3.
(Optional) If the power has been underprovisioned for your configuration, some FPCs might not be brought online if the available power capacity is exceeded. When you reboot the router, FPCs are brought online based on the default setting of the fru-poweron-sequence command. You can use the fru-poweron-sequence command to change the default order in which FPCs are brought online when the router is rebooted.
[edit] user@host# set chassis fru-poweron-sequence fru-poweron-sequence
NOTE: The default is the numerical order of the FPC slots (0 through 7).
4.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 6; input-current 40;
}
5.
Commit the configuration to activate it on the router and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
Related
Documentation
• T4000 Power System Description on page 43
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Troubleshooting the T4000 Power System on page 204
• T4000 DC Power Requirements on page 338
• T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 340
• T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 340
• T4000 Power Management Overview
Copyright © 2013, Juniper Networks, Inc.
151
T4000 Router Hardware Guide
152 Copyright © 2013, Juniper Networks, Inc.
PART 3
Upgrading to a T4000 Router from a
T640 or T1600 Router
• Preparing to Upgrade to a T4000 Router on page 155
• Upgrading to a T4000 Router on page 167
Copyright © 2013, Juniper Networks, Inc.
153
T4000 Router Hardware Guide
154 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 15
Preparing to Upgrade to a T4000 Router
• Overview of Preparing to Upgrade to a T4000 Router on page 155
• Checking the Hardware Version of T640 or T1600 Components on page 156
• T4000 Upgrade Kit on page 164
Overview of Preparing to Upgrade to a T4000 Router
To prepare to upgrade to a T4000 router:
1.
Prepare the installation site for the T4000 router.
See “Overview of Preparing the Site for the T4000 Router” on page 57 .
2.
Determine which model numbers of the following components are already installed.
See “Checking the Hardware Version of T640 or T1600 Components” on page 156 .
• Routing Engines: RE-DUO-C1800-8G or RE-DUO-C1800-16G (supported on T640 or T1600 router)
• Control boards: CB-LCC (supported on T640 or T1600 router)
• Rear fan tray: FAN-REAR-TXP-LCC (supported on T1600 router only)
• Power supplies: PWR-T-6-60-DC (supported on T640 or T1600 router)
3.
Order the required hardware.
The hardware upgrade kit includes two LCC-CBs, two RE-DUO-CI800-8G Routing
Engines, five SIB-I-T4000 SIBs, one FAN-REAR-TXP-LCC rear fan trays, two
FANTRAY-T4000 front fan trays, and two PWR-T-6-60-DC power supplies. If the required control boards, Routing Engines, rear fan tray, or power supplies are already installed in the T640 or T1600 router, you can also order the other hardware components separately.
See the “T4000 Upgrade Kit” on page 164 .
4.
Review all safety guidelines and warnings for both the T4000 router and T1600 router or T640 Router.
WARNING: To avoid harm to yourself or the router as you install and maintain it, you must follow the safety procedures for working with Internet
Copyright © 2013, Juniper Networks, Inc.
155
T4000 Router Hardware Guide routers, as well as the guidelines and warnings for working with and near electrical equipment. However, providing an exhaustive set of guidelines for working with electrical equipment is beyond the scope of this documentation.
See “General Safety Guidelines for Juniper Networks Devices” on page 293 and “General
Safety Warnings for Juniper Networks Devices” on page 294 .
5.
Upgrade the software on the T1600 router or T640 router to Junos OS Release 12.1
or later. Support of some hardware or software features require Junos OS Release
12.1R2 or later. For information about upgrading the software, see the Installation and
Upgrade Guide .
6.
Delete unsupported configurations from the T640 or T1600 router.
For example, the following CoS configuration is not supported for T4000 routers:
Hierarchy Level [edit class-of-service schedulers scheduler-name] drop-profile-map loss-priority (any | low | medium-low | medium-high | high) protocol (any| non-tcp | tcp) drop-profile profile-name.
For the T4000 router, any is the only protocol option supported for the following statement. The non-tcp and tcp options are not supported,
Hierarchy Level [edit class-of-service schedulers scheduler-name] drop-profile-map loss-priority (any | low | medium-low | medium-high | high) protocol any drop-profileprofile-name.
Related
Documentation
• T4000 Router Description on page 3
• T4000 Hardware Component Overview on page 13
Checking the Hardware Version of T640 or T1600 Components
1.
Checking the Hardware Version of the Control Boards on page 156
2.
Checking the Hardware Version of the Routing Engines on page 158
3.
Checking the Hardware Version of the Rear Fan Tray on page 160
4.
Checking the Hardware Version of the FPCs on page 162
Checking the Hardware Version of the Control Boards
The control board model number LCC-CB is required for the T4000 router.
The following control boards are not supported for the T4000 router:
• CB-L-T
• CB-T
To determine which model numbers of control boards are installed:
1.
Issue the show chassis hardware models command:
156 Copyright © 2013, Juniper Networks, Inc.
Chapter 15: Preparing to Upgrade to a T4000 Router
In this example, the output shows that two CB-L-T control boards are installed.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that two CB-T control boards are installed.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 03 710-005608 CHAS-BP-T640-S
FPM Display REV 05 710-002897 CRAFT-T640-S
CIP REV 06 710-002895 CIP-L-T640-S
PEM 0 Rev 07 740-017906 PWR-T1600-3-80-DC-S
PEM 1 Rev 18 740-002595 PWR-T-DC-S
SCG 0 REV 15 710-003423 SCG-T-S
Routing Engine 0 REV 08 740-014082 RE-A-2000-4096-S
Routing Engine 1 REV 07 740-014082 RE-A-2000-4096-S
CB 0 REV 05 710-007655 CB-T-S
CB 1 REV 03 710-017707 CB-T-S
FPC 0 REV 07 710-013558 T640-FPC2-E2
PIC 0 REV 01 750-010618 PB-4GE-SFP
PIC 1 REV 06 750-001900 PB-1OC48-SON-SMSR
PIC 2 REV 14 750-001901 PB-4OC12-SON-SMIR
PIC 3 REV 07 750-001900 PB-1OC48-SON-SMSR
FPC 1 REV 06 710-013553 T640-FPC1-E2
PIC 0 REV 08 750-001072 P-1GE-SX
PIC 1 REV 10 750-012266 PB-4GE-TYPE1-SFP-IQ2
PIC 2 REV 22 750-005634 PB-1CHOC12SMIR-QPP
FPC 2
PIC 0 REV 16 750-007141 PC-10GE-SFP
PIC 1 REV 06 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 05 750-004695 PC-TUNNEL
PIC 3 REV 17 750-009553 PC-4OC48-SON-SFP
FPC 3 REV 01 710-010154 T640-FPC3-E
PIC 0 REV 07 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 25 750-007141 PC-10GE-SFP
Copyright © 2013, Juniper Networks, Inc.
157
T4000 Router Hardware Guide
PIC 2 REV 17 750-009553 PC-4OC48-SON-SFP
PIC 3 REV 32 750-003700 PC-1OC192-SON-VSR
FPC 4 REV 16 710-013037 T1600-FPC4-ES
PIC 1 REV 06 750-034781 PD-1CE-CFP
FPC 5 REV 02 710-013037 T1600-FPC4-ES
PIC 0 REV 16 750-012518 PD-4OC192-SON-XFP
PIC 1 REV 01 750-010850 PD-1OC768-SON-SR
FPC 6 REV 14 710-013037 T1600-FPC4-ES
PIC 0 REV 11 750-017405 PD-4XGE-XFP
PIC 1 REV 13 750-017405 PD-4XGE-XFP
FPC 7 REV 09 710-007529 T640-FPC3
PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 3 REV 15 750-009450 PC-1OC192-SON-SR2
SIB 0 REV 07 710-013074 SIB-I-T1600-S
SIB 1 REV 07 710-013074 SIB-I-T1600-S
SIB 2 REV 07 710-013074 SIB-I-T1600-S
SIB 3 REV 07 710-013074 SIB-I-T1600-S
SIB 4 REV 07 710-013074 SIB-I-T1600-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that LCC-CB control boards are installed.
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed
2.
If two LCC-CB control boards are not installed, order and install LCC-CB control boards.
Checking the Hardware Version of the Routing Engines
The Routing Engine model number RE-DUO-C1800-8G or RE-DUO-C1800-16G is required for the T4000 router. The following Routing Engines are not supported on the T4000 router:
• RE-600-2048
158 Copyright © 2013, Juniper Networks, Inc.
Chapter 15: Preparing to Upgrade to a T4000 Router
• RE-1600-2048
• RE-A-2000-4096
To determine which model numbers of Routing Engines are installed:
1.
Issue the show chassis hardware models command:
In this example, the output shows that two RE-600-2048 Routing Engines are installed.
user@host> show chassis hardware models user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that two RE-A-2000-4096 Routing Engines are installed.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 03 710-005608 CHAS-BP-T640-S
FPM Display REV 05 710-002897 CRAFT-T640-S
CIP REV 06 710-002895 CIP-L-T640-S
PEM 0 Rev 07 740-017906 PWR-T1600-3-80-DC-S
PEM 1 Rev 18 740-002595 PWR-T-DC-S
SCG 0 REV 15 710-003423 SCG-T-S
Routing Engine 0 REV 08 740-014082 RE-A-2000-4096-S
Routing Engine 1 REV 07 740-014082 RE-A-2000-4096-S
CB 0 REV 05 710-007655 CB-T-S
CB 1 REV 03 710-017707 CB-T-S
FPC 0 REV 07 710-013558 T640-FPC2-E2
PIC 0 REV 01 750-010618 PB-4GE-SFP
PIC 1 REV 06 750-001900 PB-1OC48-SON-SMSR
PIC 2 REV 14 750-001901 PB-4OC12-SON-SMIR
PIC 3 REV 07 750-001900 PB-1OC48-SON-SMSR
FPC 1 REV 06 710-013553 T640-FPC1-E2
PIC 0 REV 08 750-001072 P-1GE-SX
PIC 1 REV 10 750-012266 PB-4GE-TYPE1-SFP-IQ2
Copyright © 2013, Juniper Networks, Inc.
159
T4000 Router Hardware Guide
PIC 2 REV 22 750-005634 PB-1CHOC12SMIR-QPP
FPC 2
PIC 0 REV 16 750-007141 PC-10GE-SFP
PIC 1 REV 06 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 05 750-004695 PC-TUNNEL
PIC 3 REV 17 750-009553 PC-4OC48-SON-SFP
FPC 3 REV 01 710-010154 T640-FPC3-E
PIC 0 REV 07 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 25 750-007141 PC-10GE-SFP
PIC 2 REV 17 750-009553 PC-4OC48-SON-SFP
PIC 3 REV 32 750-003700 PC-1OC192-SON-VSR
FPC 4 REV 16 710-013037 T1600-FPC4-ES
PIC 1 REV 06 750-034781 PD-1CE-CFP
FPC 5 REV 02 710-013037 T1600-FPC4-ES
PIC 0 REV 16 750-012518 PD-4OC192-SON-XFP
PIC 1 REV 01 750-010850 PD-1OC768-SON-SR
FPC 6 REV 14 710-013037 T1600-FPC4-ES
PIC 0 REV 11 750-017405 PD-4XGE-XFP
PIC 1 REV 13 750-017405 PD-4XGE-XFP
FPC 7 REV 09 710-007529 T640-FPC3
PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 3 REV 15 750-009450 PC-1OC192-SON-SR2
SIB 0 REV 07 710-013074 SIB-I-T1600-S
SIB 1 REV 07 710-013074 SIB-I-T1600-S
SIB 2 REV 07 710-013074 SIB-I-T1600-S
SIB 3 REV 07 710-013074 SIB-I-T1600-S
SIB 4 REV 07 710-013074 SIB-I-T1600-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
2.
If two RE-DUO-C1800-8G Routing Engines are not installed, order and install
RE-DUO-C1800-8G Routing Engines.
Checking the Hardware Version of the Rear Fan Tray
The rear fan tray model number FAN-REAR-TXP-LCC has eight fans and is required to support the additional thermal power generation of the T4000 router.
The following fan trays do not provide sufficient cooling for the T4000 router:
• RHTREARTRAY-T
• FAN-REAR-TX-T640
• FAN-R
• FAN-REAR-T
To determine which version of the rear fan tray is installed:
1.
Issue the show chassis environment command:
160 Copyright © 2013, Juniper Networks, Inc.
Chapter 15: Preparing to Upgrade to a T4000 Router
In this example, the output shows that the rear fan tray has five blowers, indicating that the RHTREARTRAY-T rear fan tray is installed. The last five lines of the output for the fans each include Blower in the description.
user@host> show chassis environment
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Fourth Blower from top OK Spinning at normal speed
Bottom Blower OK Spinning at normal speed
Middle Blower OK Spinning at normal speed
Top Blower OK Spinning at normal speed
Second Blower from top OK Spinning at normal speed
In this example, the output shows that the rear fan tray has eight fans, indicating that
FAN-REAR-TX-T640-S rear fan tray is installed. The last eight lines of the output for the fans each begin with Rear Tray and include fan in the description.
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed
2.
Issue the show chassis hardware models command.
In this example, the output shows that FAN-REAR-TX-T640 is installed.
user@host> show chassis hardware models user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
Copyright © 2013, Juniper Networks, Inc.
161
T4000 Router Hardware Guide
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
3.
If the FAN-REAR-TXP-LCC rear fan tray is not installed, order and install the
FAN-REAR-TXP-LCC rear fan tray.
Checking the Hardware Version of the FPCs
The FPCs supported for the T4000 router are listed in “T4000 FPCs Supported” on page 34 . We recommend that you remove unsupported FPCs before installing the T4000
SIBs.
To determine which model numbers of FPCs are installed:
1.
Issue the show chassis hardware models command:
In this example, the output shows that the T640-FPC2 and T640-FPC3 FPCs are installed.
user@host> show chassis hardware models user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that T640-FPC2-E2 , T640-FPC1-E2 , T640-FPC3-E , and T1600-FPC4-ES FPCs are installed. The T1600-FPC4-ES FPCs are supported for
162 Copyright © 2013, Juniper Networks, Inc.
Chapter 15: Preparing to Upgrade to a T4000 Router the T4000 router. All other FPCs in the this example are currently unsupported for the T4000 router.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 03 710-005608 CHAS-BP-T640-S
FPM Display REV 05 710-002897 CRAFT-T640-S
CIP REV 06 710-002895 CIP-L-T640-S
PEM 0 Rev 07 740-017906 PWR-T1600-3-80-DC-S
PEM 1 Rev 18 740-002595 PWR-T-DC-S
SCG 0 REV 15 710-003423 SCG-T-S
Routing Engine 0 REV 08 740-014082 RE-A-2000-4096-S
Routing Engine 1 REV 07 740-014082 RE-A-2000-4096-S
CB 0 REV 05 710-007655 CB-T-S
CB 1 REV 03 710-017707 CB-T-S
FPC 0 REV 07 710-013558 T640-FPC2-E2
PIC 0 REV 01 750-010618 PB-4GE-SFP
PIC 1 REV 06 750-001900 PB-1OC48-SON-SMSR
PIC 2 REV 14 750-001901 PB-4OC12-SON-SMIR
PIC 3 REV 07 750-001900 PB-1OC48-SON-SMSR
FPC 1 REV 06 710-013553 T640-FPC1-E2
PIC 0 REV 08 750-001072 P-1GE-SX
PIC 1 REV 10 750-012266 PB-4GE-TYPE1-SFP-IQ2
PIC 2 REV 22 750-005634 PB-1CHOC12SMIR-QPP
FPC 2
PIC 0 REV 16 750-007141 PC-10GE-SFP
PIC 1 REV 06 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 05 750-004695 PC-TUNNEL
PIC 3 REV 17 750-009553 PC-4OC48-SON-SFP
FPC 3 REV 01 710-010154 T640-FPC3-E
PIC 0 REV 07 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 25 750-007141 PC-10GE-SFP
PIC 2 REV 17 750-009553 PC-4OC48-SON-SFP
PIC 3 REV 32 750-003700 PC-1OC192-SON-VSR
FPC 4 REV 16 710-013037 T1600-FPC4-ES
PIC 1 REV 06 750-034781 PD-1CE-CFP
FPC 5 REV 02 710-013037 T1600-FPC4-ES
PIC 0 REV 16 750-012518 PD-4OC192-SON-XFP
PIC 1 REV 01 750-010850 PD-1OC768-SON-SR
FPC 6 REV 14 710-013037 T1600-FPC4-ES
PIC 0 REV 11 750-017405 PD-4XGE-XFP
PIC 1 REV 13 750-017405 PD-4XGE-XFP
FPC 7 REV 09 710-007529 T640-FPC3
PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 3 REV 15 750-009450 PC-1OC192-SON-SR2
SIB 0 REV 07 710-013074 SIB-I-T1600-S
SIB 1 REV 07 710-013074 SIB-I-T1600-S
SIB 2 REV 07 710-013074 SIB-I-T1600-S
SIB 3 REV 07 710-013074 SIB-I-T1600-S
SIB 4 REV 07 710-013074 SIB-I-T1600-S
Fan Tray 0 FANTRAY-T-S
Copyright © 2013, Juniper Networks, Inc.
163
T4000 Router Hardware Guide
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
2.
Remove all unsupported FPCs. To minimize downtime, you can upgrade FPCs that are supported on both the T640 router or T1600 router and the T4000 router before the upgrade to a T4000 router.
NOTE: The following FPCs cannot be installed until all other hardware components for the T4000 router have been installed.
• T1600-FPC4-ES FPCs cannot be installed on T640 routers that have not been upgraded. The T1600-FPC4-ES FPC is not supported on T640 routers.
• T4000-FPC5-3D FPCs cannot be installed on T640 or T1600 routers that have not been upgraded.
Related
Documentation
• Overview of Upgrading to a T4000 Router on page 167
• T4000 Upgrade Kit on page 164
T4000 Upgrade Kit
The following hardware components are required for an upgrade from a Juniper Networks
T640 Core Router or T1600 Core Router to a T4000 Core Router.
• Two redundant, load-sharing six-input DC power supplies (PWR-T-6-60-DC)
• Five T4000 SIBs (SIB-I-T4000)
• One T Series craft interface panel (CRAFT-T-SERIES)
• Two front fan trays (FANTRAY-T4000)
• One rear fan tray (FAN-REAR-TXP-LCC)
• Two Routing Engines (RE-DUO-C1800-8G)
NOTE: RE-DUO-C1800-16G is also supported
• Two control boards (CB-LCC)
You can order these components individually or order a T4000 upgrade kit that contains all the components. You might need additional DC power cables.
NOTE: These components must be installed before you can install a T4000
FPC5 in the T4000 router.
164 Copyright © 2013, Juniper Networks, Inc.
Chapter 15: Preparing to Upgrade to a T4000 Router
Related
Documentation
• Checking the Hardware Version of T640 or T1600 Components on page 156
• Overview of Upgrading to a T4000 Router on page 167
Copyright © 2013, Juniper Networks, Inc.
165
T4000 Router Hardware Guide
166 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 16
Upgrading to a T4000 Router
• Overview of Upgrading to a T4000 Router on page 167
• Upgrading Hardware Components on the T640 or T1600 Router on page 168
• Upgrading to T4000 SIBs with Junos OS Release 12.1 on page 172
• Upgrading to T4000 SIBs Online with Junos OS Release 12.2 and Later on page 173
• Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router on page 175
• Registering Your T4000 Upgrade on page 175
Overview of Upgrading to a T4000 Router
To upgrade to a T4000 Router:
1.
Verify that you have prepared the T640 or T1600 router for the upgrade. See “Overview of Preparing to Upgrade to a T4000 Router” on page 155 .
2.
Verify that you have all the hardware required to upgrade to a T4000 router. See the following documentation:
• T4000 Upgrade Kit on page 164
• Checking the Hardware Version of T640 or T1600 Components on page 156
3.
Upgrade the hardware components on the T640 or T1600 router. See “Upgrading
Hardware Components on the T640 or T1600 Router” on page 168 .
4.
Upgrade the SIBs using one of the following procedures:
• For the Junos OS Release 12.1, see “Upgrading to T4000 SIBs with Junos OS Release
12.1” on page 172 .
• For the Junos OS Release 12.2 and later, see “Upgrading to T4000 SIBs Online with
Junos OS Release 12.2 and Later” on page 173 .
5.
For Junos OS Release 12.3 and later, configure power management, if needed. See the following documentation:
• Configuring DC Power on a T4000 Router on page 148
• T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 340
Copyright © 2013, Juniper Networks, Inc.
167
T4000 Router Hardware Guide
• T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 340
6.
After the SIBs have been upgraded and power management has been configured, you can install the T4000 FPCs. See “Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router” on page 175 .
7.
Register your upgrade. See “Registering Your T4000 Upgrade” on page 175 .
Related
Documentation
• T4000 Router Description on page 3
Upgrading Hardware Components on the T640 or T1600 Router
The following components are supported on the T640 and T1600 router, and can be installed without powering off or rebooting the router.
You must proceed through the upgrade process in the following order:
1.
Preparing to Upgrade the T640 or T1600 Components on page 168
2.
Upgrade to the Six-Input DC Power Supplies on page 169
3.
Upgrade the Fan Trays on page 169
4.
Upgrading the Host Subsystem on page 170
5.
Removing Unsupported FPCs and PICs on page 170
6.
Verify That Components Supported by the T4000 Router Are Installed on page 171
Preparing to Upgrade the T640 or T1600 Components
1.
Unpack the upgrade components and verify the parts received.
2.
Gather the tools required to upgrade the T4000 router hardware components.
168 Copyright © 2013, Juniper Networks, Inc.
Chapter 16: Upgrading to a T4000 Router
Upgrade to the Six-Input DC Power Supplies
To upgrade to the six-input DC power supply:
NOTE: This procedure does not apply to T640 or T1600 routers with AC power supplies. In that case, both AC power supplies must be powered off and removed before the DC power supplies are installed.
1.
Verify that the number of inputs that you plan to connect to the 6-input DC power supply provides sufficient power for your planned configuration for the T4000 router.
NOTE: For the Junos OS Release 12.1 and 12.2, a minimum of five inputs for each power supply is required. Connecting only four inputs to each DC power supply in a T4000 router is not currently supported.
2.
Remove one of the existing power supplies. For information about removing T640 or
T1600 components, see the T640 Core Router Hardware Guide or T1600 Core Router
Hardware Guide .
3.
Install one six-input DC power supply.
4.
Connect the DC power cables to the six-input DC power supply.
5.
Repeat the procedure for the other power supply.
Upgrade the Fan Trays
To upgrade the fan trays:
1.
Upgrade the front fan trays.
2.
Upgrade the rear fan tray, if needed. FAN-REAR-TXP-LCC rear fan tray is required.
Install the FAN-REAR-TXP-LCC rear fan tray, if not already installed.
Copyright © 2013, Juniper Networks, Inc.
169
T4000 Router Hardware Guide
Upgrading the Host Subsystem
Upgrade the host subsystem, if needed. For information about upgrading the host subsystem, see the hardware guide for the T640 or T1600 router:
• T640 Core Router Hardware Guide
• T1600 Core Router Hardware Guide
NOTE: Upgrading a Routing Engine or Control board requires that the host subsystem be taken offline. Upgrade the backup Routing Engine and control board first, bring them online, then upgrade the other Routing Engine and control board.
1.
Take the host subsystem offline.
2.
Upgrade the backup Routing Engine.
3.
Upgrade the backup control board.
4.
Verify that the two configuration switches on the faceplate of the LCC-CB are set correctly for a standalone T4000 router:
• The M/S configuration switch must be set to S .
• The CHASSIS ID configuration switch must be set to 0 .
5.
Take the other host subsystem offline.
6.
Repeat the procedure for the other Routing Engine and control board.
Removing Unsupported FPCs and PICs
NOTE: Although you can choose to leave unsupported FPCs and PICs in the
T640 or T1600 router, the FPCs and PICs installed in those FPCs will not come online in the T4000 router, and will not function.
To remove unsupported PICs and FPCs from the T640 or T1600 router:
1.
Determine the FPCs supported by the T4000 router for your Junos OS Release. For a list of the FPCs supported by the T4000 router, see “T4000 FPCs Supported” on page 34 .
2.
Remove FPCs not supported by the T4000 router. . Install blanks in the FPC slots.
3.
Determine the PICs supported by the T4000 router for your Junos OS Release. For a list of PICs supported by the T4000 router, see the T4000 Interface Module Reference .
4.
Remove PICs not supported by the T4000 router.
170 Copyright © 2013, Juniper Networks, Inc.
Chapter 16: Upgrading to a T4000 Router
Verify That Components Supported by the T4000 Router Are Installed
To verify that the hardware components supported by the T4000 router are installed on the T640 or T1600 router:
1.
Issue the show chassis hardware models command: user@host> show chassis hardware models
Hardware inventory:
Item Version Part number Serial number FRU model number
Midplane REV 01 710-027486 RC9244 CHAS-BP-T1600-S
FPM Display REV 03 710-021387 BBAF4338 CRAFT-T1600-S
CIP REV 06 710-002895 BBAF2353 CIP-L-T640-S
PEM 0 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
PEM 1 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
SCG 0 REV 18 710-003423 BBAE4908 SCG-T-S
SCG 1 REV 18 710-003423 BBAB2590 SCG-T-S
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-C1800-8G-S
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-C1800-8G-S
CB 0 REV 09 710-022597 EF6057 CB-LCC-S
CB 1 REV 09 710-022597 EF9180 CB-LCC-S
FPC 5 REV 03 710-033871 IPUCAMBCTD T1600-FPC4-ES
PIC 1 REV 03 750-034781 IPUIBKLMAA PD-1CE-CFP-FPC4
SIB 0 REV 02 750-005486 SIB-I-T640-S
SIB 1 REV 02 750-005486 SIB-I-T640-S
SIB 2 REV 02 750-005486 SIB-I-T640-S
SIB 3 REV 02 750-005486 SIB-I-T640-S
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T4000-S
Fan Tray 1 FANTRAY-T4000-S
Fan Tray 2 FAN-REAR-TXP-LCC-S
2.
Verify that the following hardware components have been installed:
• Two PWR-T-6-60-DC
• Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G
• Two CB-LCC
• Two FANTRAY-T4000
• One FAN-REAR-TXP-LCC
3.
Verify that unsupported PICs and FPCs have been removed. See the following documentation:
• For a list of the FPCs supported by the T4000 router, see “T4000 FPCs Supported” on page 34 .
• For a list of PICs supported by the T4000 router, see the T4000 Interface Module
Reference .
Copyright © 2013, Juniper Networks, Inc.
171
T4000 Router Hardware Guide
Upgrading to T4000 SIBs with Junos OS Release 12.1
NOTE: You must use this procedure for Junos OS Release 12.1.
You must proceed through the upgrade process in the following order:
1.
Unpack the T4000 SIBs and verify the parts received.
2.
Gather the tools required to upgrade the T4000 SIBs.
3.
Include the fabric upgrade-mode statement in the configuration of the T640 or T1600 router at the [edit chassis] hierarchy level.
[edit] user@host# set chassis fabric upgrade-mode
4.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
5.
On the T640 router or the T1600 router, verify that upgrade mode has been set.
[edit] user@host# show chassis fabric upgrade-mode
6.
Install the SIB-I-T4000 SIBs. Replace one SIB at a time.
After each SIB is replaced, bring the newly installed SIB online, and check for crc errors and link status with the following commands before adding another SIB:
• Use the show chassis sib command to check the SIB state. The state should be
Online , indicating that the SIB is operational and running.
• Use the show chassis fabric fpc to check the switch fabric links between the Flexible
PIC Concentrators (FPCs) and the switch interface boards (SIBs). The Fabric management FPC state should be Links ok . The Link error state indicates that the link between the SIB and FPC has CRC errors. However, the link is still eligible to carry traffic.
• Use the show chassis fabric sib to check the switch fabric links between the SIBs and FPCs. The Fabric management SIB state should be Links ok . The Link error state indicates that the link between the SIB and the FPC is not operational.
7.
Delete the fabric upgrade-mode statement in the configuration of the T4000 router at the [edit chassis] hierarchy level.
[edit] user@host# delete chassis fabric upgrade-mode
8.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
9.
Power off the T1600 router or T640 router.
172 Copyright © 2013, Juniper Networks, Inc.
Chapter 16: Upgrading to a T4000 Router
See the T640 Core Router Hardware Guide or T1600 Core Router Hardware Guide .
10.
Power on the T4000 router.
See “Powering On the T4000 Router” on page 141 .
11.
Issue the show chassis hardware models command: user@host> show chassis hardware models
Hardware inventory:
Item Version Part number Serial number FRU model number
Midplane REV 01 710-027486 RC9244 CHAS-BP-T1600-S
FPM Display REV 03 710-021387 BBAF4338 CRAFT-T1600-S
CIP REV 06 710-002895 BBAF2353 CIP-L-T640-S
PEM 0 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
PEM 1 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
SCG 0 REV 18 710-003423 BBAE4908 SCG-T-S
SCG 1 REV 18 710-003423 BBAB2590 SCG-T-S
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-C1800-8G-S
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-C1800-8G-S
CB 0 REV 09 710-022597 EF6057 CB-LCC-S
CB 1 REV 09 710-022597 EF9180 CB-LCC-S
SIB 0 REV 02 711-036340 EE6290
SIB 1 REV 02 711-036340 EE6290
SIB 2 REV 02 711-036340 EE6290
SIB 3 REV 02 711-036340 EE6290
SIB 4 REV 02 711-036340 EE6290
Fan Tray 0 FANTRAY-T4000-S
Fan Tray 1 FANTRAY-T4000-S
Fan Tray 2 FAN-REAR-TXP-LCC-S
Related
Documentation
• T4000 Upgrade Kit on page 164
• Checking the Hardware Version of T640 or T1600 Components on page 156
Upgrading to T4000 SIBs Online with Junos OS Release 12.2 and Later
NOTE: This procedure requires 64-bit Junos OS Release 12.2 and later.
You must proceed through the upgrade process in the following order:
1.
Unpack the T4000 SIBs and verify the parts received.
2.
Gather the tools required to upgrade the T4000 SIBs.
3.
Verify that both Routing Engines in the T640 or T1600 router are running a 64-bit
Junos Release 12.2 and later.
user@host> show version
Hostname: host
Hostname: quietriot1
Model: t1600
JUNOS Base OS boot [12.2R1.1]
JUNOS Base OS Software Suite [12.2R1.1]
JUNOS 64-bit Kernel Software Suite [12.2R1.1]
...
Copyright © 2013, Juniper Networks, Inc.
173
T4000 Router Hardware Guide
174
4.
Include the fabric upgrade-mode statement in the configuration of the T640 or T1600 router at the [edit chassis] hierarchy level.
[edit] user@host# set chassis fabric upgrade-mode T4000
5.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
6.
On the T640 router or the T1600 router, verify that upgrade mode has been set.
[edit] user@host# show chassis fabric upgrade-mode
7.
Install the SIB-I-T4000 SIBs. Replace one SIB at a time.
After each SIB is replaced, bring the newly installed SIB online, and check for crc errors and link status with the following commands before adding another SIB:
• Use the show chassis sib to check the SIB state. The state should be Online , indicating that the SIB is operational and running.
• Use the show chassis fabric fpc to check the switch fabric links between the Flexible
PIC Concentrators (FPCs) and the switch interface boards (SIBs). The Fabric management FPC state should be Links ok . The Link error state indicates that the link between the SIB and FPC has CRC errors. However, the link is still eligible to carry traffic.
• Use the show chassis fabric sib to check the switch fabric links between the SIBs and FPCs. The Fabric management SIB state should be Links ok . The Link error state indicates that the link between the SIB and the FPC is not operational.
8.
Delete the fabric upgrade-mode T4000 statement in the configuration of the T4000 router at the [edit chassis] hierarchy level.
[edit] user@host# delete chassis fabric upgrade-mode T4000
9.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
10.
Issue the show chassis hardware models command: user@host> show chassis hardware models
Hardware inventory:
Item Version Part number Serial number FRU model number
Midplane REV 01 710-027486 RC9244 CHAS-BP-T1600-S
FPM Display REV 03 710-021387 BBAF4338 CRAFT-T1600-S
CIP REV 06 710-002895 BBAF2353 CIP-L-T640-S
PEM 0 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
PEM 1 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
SCG 0 REV 18 710-003423 BBAE4908 SCG-T-S
SCG 1 REV 18 710-003423 BBAB2590 SCG-T-S
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-C1800-8G-S
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-C1800-8G-S
CB 0 REV 09 710-022597 EF6057 CB-LCC-S
Copyright © 2013, Juniper Networks, Inc.
Chapter 16: Upgrading to a T4000 Router
CB 1 REV 09 710-022597 EF9180 CB-LCC-S
SIB 0 REV 02 711-036340 EE6290
SIB 1 REV 02 711-036340 EE6290
SIB 2 REV 02 711-036340 EE6290
SIB 3 REV 02 711-036340 EE6290
SIB 4 REV 02 711-036340 EE6290
Fan Tray 0 FANTRAY-T4000-S
Fan Tray 1 FANTRAY-T4000-S
Fan Tray 2 FAN-REAR-TXP-LCC-S
Related
Documentation
• T4000 Upgrade Kit on page 164
• Checking the Hardware Version of T640 or T1600 Components on page 156
Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router
After the SIBs have been upgraded, you can install Type 5 FPCs and PICs.
1.
Install the Type 5 FPCs (T4000 FPC5).
See “Installing a T4000 FPC” on page 245
2.
Install Type 5 PICs.
See “Installing a T4000 PIC” on page 255 .
Related
Documentation
• T4000 FPC Description on page 30
• T4000 PIC Description on page 42
• Overview of Upgrading to a T4000 Router on page 167
Registering Your T4000 Upgrade
You must register the upgrade with Juniper Networks upon completion of the upgrade.
To register your upgrade:
1.
Log on to the Juniper Networks Customer Support Center at http://www.juniper.net/customers/support/ .
2.
Click on Update Install Base .
3.
Follow the instructions provided in this link.
After your upgrade is registered, allow up to 45 days for restocking of the new hardware configuration to support any Next Day or Same Day contracts. Juniper Networks will provide Best Effort support until restocking of the upgraded product is complete.
Related
Documentation
• Overview of Upgrading to a T4000 Router on page 167
Copyright © 2013, Juniper Networks, Inc.
175
T4000 Router Hardware Guide
176 Copyright © 2013, Juniper Networks, Inc.
PART 4
Maintenance, Troubleshooting, and
Replacement Procedures
• Maintaining T4000 Router Hardware Components on page 179
• Troubleshooting T4000 Router Hardware Components on page 189
• Replacing T4000 Router Hardware Components on page 215
Copyright © 2013, Juniper Networks, Inc.
177
T4000 Router Hardware Guide
178 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 17
Maintaining T4000 Router Hardware
Components
• Tools and Parts Required to Maintain the T4000 Hardware Components on page 179
• Routine Maintenance Procedures for the T4000 Router on page 179
• Maintaining T4000 Cooling System Components on page 180
• Maintaining the T4000 Routing Engine and Control Boards on page 182
• Maintaining T4000 FPCs on page 184
• Maintaining T4000 PICs on page 184
• Maintaining PIC Cables on page 185
• Maintaining the T4000 Power System on page 186
• Maintaining the T4000 SIBs on page 186
• Maintaining the T4000 SCGs on page 187
Tools and Parts Required to Maintain the T4000 Hardware Components
To maintain the hardware components, you need the following tools and parts:
• ESD grounding wrist strap
• Flat-blade (–) screwdriver
• Phillips (+) screwdriver, number 1
• Phillips (+) screwdriver, number 2
Related
Documentation
• Routine Maintenance Procedures for the T4000 Router on page 179
Routine Maintenance Procedures for the T4000 Router
Purpose For optimum router performance, perform preventive maintenance procedures.
Action On a regular basis:
• Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the router and into the air intake vents.
Copyright © 2013, Juniper Networks, Inc.
179
T4000 Router Hardware Guide
• Check the status-reporting devices on the craft interface: system alarms, LEDs, and
LCD.
• Inspect the air filters at the bottom front and left rear of the router. Do not run the router for more than a few minutes without the air filters in place.
Check the air filters regularly for dust and debris. As a general guideline, we recommended that you replace the filter elements every 6 months for routers operating in a typical environment. The filter elements degrade over time, and replacement intervals will vary by operating environment.
Related
Documentation
• T4000 Cooling System Description on page 21
• T4000 Craft Interface Description on page 23
• Maintaining the T4000 Air Filters on page 180
Maintaining T4000 Cooling System Components
• Maintaining the T4000 Air Filters on page 180
• Maintaining the T4000 Fan Trays on page 181
Maintaining the T4000 Air Filters
Purpose For optimum cooling, verify the condition of the air filters.
Air filters for both the front and rear fan trays help keep dust and other particles from entering the cooling system. To function properly, the entire cooling system requires an unobstructed airflow and proper clearance around the site, as described in “T4000
Clearance Requirements for Airflow and Hardware Maintenance” on page 59 . See
Figure 88 on page 180 .
Figure 88: Airflow Through the Chassis
180
Action Check the air filters regularly for dust and debris. As a general guideline, we recommended that you replace the filter elements every 6 months for routers operating in a typical
Copyright © 2013, Juniper Networks, Inc.
Chapter 17: Maintaining T4000 Router Hardware Components environment. The filter elements degrade over time, and replacement intervals will vary by operating environment.
For procedures to replace the air filters, see the following topics:
• Replacing a T4000 Rear Air Filter on page 220
• Replacing a T4000 Front Air Filter on page 218
• Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 264
• Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 265
We recommend that you use spare filter elements within 1 year of manufacture. Check the date of manufacture printed on the filter. Store spare filter elements in a dark, cool, and dry place. Storing the filter elements at higher temperatures, or where they can be exposed to ultraviolet (UV) radiation, hydrocarbon emissions, or vapors from solvents, can significantly reduce their life.
CAUTION: Always keep the air filters in place while the router is operating.
Because the fans are very powerful, they could pull small bits of wire or other materials into the router through the unfiltered air intake. This could damage the router components.
Related
Documentation
• T4000 Cooling System Description on page 21
• Maintaining the T4000 Fan Trays on page 181
• Troubleshooting the T4000 Cooling System on page 193
Maintaining the T4000 Fan Trays
Purpose For optimum cooling, verify the condition of the fans.
Action On a regular basis, monitor the status of the fans. The fan trays each contain multiple fans that work in unison to cool the router components. During normal operation, the status of each fan is OK , and the fans in each fan tray function at normal speed. Use the show chassis environment and show chassis fan commands to verify the status of the fans.
Related
Documentation
• T4000 Cooling System Description on page 21
• Maintaining the T4000 Air Filters on page 180
• Troubleshooting the T4000 Cooling System on page 193
• Chassis Operational Mode Commands
Copyright © 2013, Juniper Networks, Inc.
181
T4000 Router Hardware Guide
Maintaining the T4000 Routing Engine and Control Boards
• Maintaining the T4000 Host Subsystem on page 182
• Maintaining the T4000 Routing Engines on page 182
• Maintaining the T4000 Control Boards on page 183
Maintaining the T4000 Host Subsystem
Purpose For optimum router performance, verify the condition of the Routing Engines and the control boards.
Action Each host subsystem comprises a Routing Engine and an adjacent control board functioning together. To maintain the host subsystem:
• Check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
If the red HOST0 FAIL or HOST1 FAIL LED is lit, see “Troubleshooting the T4000 Host
Subsystems” on page 196
• Check the LEDs on the control board. See “Maintaining the T4000 Control Boards” on page 183 .
• Check the LEDs on the Routing Engine. See “Maintaining the T4000 Routing Engines” on page 182
Related
Documentation
• T4000 Craft Interface LEDs on page 25
• T4000 LCC-CB Control Board LEDs on page 37
• T4000 RE-C1800 LEDs on page 41
Maintaining the T4000 Routing Engines
Purpose For optimum router performance, verify the condition of the Routing Engines.
Action On a regular basis:
• Check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
182 Copyright © 2013, Juniper Networks, Inc.
Chapter 17: Maintaining T4000 Router Hardware Components
If the red HOST0 FAIL or HOST1 FAIL LED is lit, see “Troubleshooting the T4000 Host
Subsystems” on page 196
• Check the LEDs on the Routing Engine. During normal operation, the ONLINE LED on each Routing Engine is lit green, indicating that the Routing Engine is functional.
• Check the LCD on the craft interface to view information about the router temperature and the status of the Routing Engines.
• Use the show chassis routing-engine command to check the status of the Routing
Engines.
Related
Documentation
• T4000 Craft Interface LEDs on page 25
• T4000 RE-C1800 LEDs on page 41
• Maintaining the T4000 Host Subsystem on page 182
• Maintaining the T4000 Control Boards on page 183
• Troubleshooting the T4000 Routing Engines on page 199
• Chassis Operational Mode Commands
Maintaining the T4000 Control Boards
Purpose For optimum router performance, verify the condition of the control boards.
Action On a regular basis:
• Check the LEDs on the control board faceplate. During normal operations:
• The green OK LED on the control board faceplate is lit.
• The yellow FAIL LED on the control board faceplate is not lit. if the FAIL is lit, see
“Troubleshooting the T4000 Host Subsystems” on page 196 and “Troubleshooting the T4000 Control Boards” on page 197 .
• Check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
If the red HOST0 FAIL or HOST1 FAIL LED is lit, see “Troubleshooting the T4000 Host
Subsystems” on page 196 and “Troubleshooting the T4000 Control Boards” on page 197 .
• Use the show chassis environment cb command to check the status of the control boards. During normal operations, the control board is online .
Related
Documentation
• T4000 LCC-CB Control Board LEDs on page 37
• Maintaining the T4000 Host Subsystem on page 182
Copyright © 2013, Juniper Networks, Inc.
183
T4000 Router Hardware Guide
• Maintaining the T4000 Routing Engines on page 182
• Chassis Operational Mode Commands
Maintaining T4000 FPCs
Purpose For optimum router performance, verify the condition of the FPCs. The router can have up to eight FPCs mounted vertically in the FPC card cage at the front of the chassis.
Action On a regular basis:
• Check the LEDs on the craft interface directly above each FPC slot. During normal operation:
• The green OK LED above the FPC on the craft interface lights steadily when the FPC is online and functioning normally.
• The green OK LED blinks during startup.
• The red FAIL LED above the FPC on the craft interface is not lit. If the FAIL is lit, see
“Troubleshooting the T4000 FPCs” on page 200 .
• Check the LCD on the craft interface.
• Use the show chassis fpc command to verify the status of installed FPCs. The value
Online in the column labeled State indicates that the FPC is functioning normally.
Related
Documentation
• T4000 Craft Interface LEDs on page 25
• T4000 FPC Description on page 30
• Chassis Operational Mode Commands
Maintaining T4000 PICs
Purpose For optimum router performance, verify the condition of the PICs.
Action On a regular basis:
• Check the LEDs on PIC faceplates. A PIC LED lit green indicates the PIC is functioning normally.
The meaning of the LED states differs for various PICs. For more information, see the
T4000 Interface Module Reference . If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
• Use the show chassis fpc pic-status command or show chassis pic comand. The PIC slots in an FPC are numbered from 0 through 1 , top to bottom:
Related
Documentation
• T4000 PIC Description on page 42
• Troubleshooting the T4000 PICs on page 208
184 Copyright © 2013, Juniper Networks, Inc.
Chapter 17: Maintaining T4000 Router Hardware Components
• Chassis Operational Mode Commands
Maintaining PIC Cables
Purpose For optimum router performance, verify the condition of the PIC cables.
Action On a regular basis:
• Use the cable management system to support cables and prevent cables from dislodging or developing stress points.
• Place excess cable out of the way in the cable management system. Do not allow fastened loops of cable to dangle from the connector or cable management system, which stresses the cable at the fastening point. Putting fasteners on the loops helps to maintain their shape.
• Keep the cable connections clean and free of dust and other particles, which can cause drops in the received power level. Always inspect cables and clean them if necessary before connecting an interface.
• Label both ends of PIC cables to identify them.
The following guidelines apply specifically to fiber-optic cable:
• When you unplug a fiber-optic cable from a PIC, always place a rubber safety plug over the transceiver on the PIC faceplate and on the end of the cable.
• Anchor fiber-optic cable to avoid stress on the connectors. When attaching fiber to a
PIC, be sure to secure the fiber so it is not supporting its own weight as it hangs to the floor. Never let fiber-optic cable hang free from the connector.
• Avoid bending fiber-optic cable beyond its bend radius. An arc smaller than a few inches can damage the cable and cause problems that are difficult to diagnose.
• Frequent plugging and unplugging of fiber-optic cable into and out of optical instruments, such as SONET/SDH analyzers, can cause damage to the instruments that is expensive to repair. Instead, attach a short fiber extension to the optical equipment. Any wear and tear due to frequent plugging and unplugging is then absorbed by the short fiber extension, which is easy and inexpensive to replace.
• Keep fiber-optic cable connections clean. Small microdeposits of oil and dust in the canal of the transceiver or cable connector could cause loss of light, reducing signal power and possibly causing intermittent problems with the optical connection.
To clean the transceivers, use an appropriate fiber-cleaning device, such as RIFOCS
Fiber Optic Adaptor Cleaning Wands (part number 946). Follow the directions for the cleaning kit you use.
After you have cleaned the transceiver on the fiber-optic PIC, make sure that the connector tip of the fiber-optic cable is clean. Use only an approved alcohol-free fiber-optic cable cleaning kit, such as the Opptex Cletop-S Fiber Cleaner. Follow the directions for the cleaning kit you use.
Copyright © 2013, Juniper Networks, Inc.
185
T4000 Router Hardware Guide
Maintaining the T4000 Power System
Purpose For optimum router performance, verify the condition of the power supplies and grounding.
Action On a regular basis:
• Check the red and yellow alarm LEDs and the LCD on the craft interface. Power supply failure or removal triggers an alarm that causes one or both of the LEDs to light and an error message to appear on the LCD. You can display the associated error messages by issuing the following CLI command: user@host> show chassis alarms
For a list of possible alarm messages, see “Troubleshooting the T4000 Power System” on page 204 .
• Make sure that the DC power cables are arranged so that they do not obstruct access to other router components.
• The power supplies require an unobstructed airflow at both the front and rear of the chassis. Periodically check the site to ensure that both the air intake at the bottom front of the chassis and the exhaust from the power supply faceplates are unobstructed.
• Periodically inspect the site to ensure that the grounding and power cables connected to the router are securely in place and that no moisture is accumulating near the router.
To review grounding and site wiring requirements for the router, see “T4000 DC Power
Cable and Lugs Specifications” on page 341 and “T4000 Chassis Grounding Cable and
Lug Specifications” on page 335 .
• Use the show chassis environment pem command to verify the status of the power supplies.
• Routinely check the status LEDs on the power supply faceplates to verify that the power supplies are functioning normally. During normal operation:
• The blue DC OK LEDs light to indicate that the power supplies are functioning normally.
• Each green INPUT PRESENT LED on a DC power supply lights when the input is receiving source DC power.
Related
Documentation
• T4000 Power System Description on page 43
• T4000 Six-Input DC Power Supply LEDs on page 45
• Chassis Operational Mode Commands
Maintaining the T4000 SIBs
Purpose For optimum router performance, verify the condition of the SIBs.
186 Copyright © 2013, Juniper Networks, Inc.
Chapter 17: Maintaining T4000 Router Hardware Components
Action On a regular basis:
• Check the LEDs on the SIB faceplate and on the craft interface. During normal operations:
• The green OK LED is lit.
• The red FAIL LED is not lit. If the red FAIL is lit, see “Troubleshooting the T4000 SIBs” on page 209 .
• Use the show chassis environment sib command to verify the status of the SIBs.
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000 Craft Interface LEDs on page 25
• T4000 SIB LEDs on page 48
• Chassis Operational Mode Commands
Maintaining the T4000 SCGs
Purpose For optimum router performance, verify the condition of the SCGs.
Action On a regular basis:
• Check the SCG LEDs. During normal operations:
• The green OK LED on the SCG faceplate is lit.
• The yellow FAIL LED on the SCG faceplate is not lit. If the yellow FAIL LED is lit, see
“Troubleshooting the T4000 SCGs” on page 208 .
• Use the show chassis environment scg command to verify the status of the SCGs.
Related
Documentation
• T4000 SONET Clock Generators (SCGs) Description on page 49
• T4000 SONET Clock Generators (SCGs) LEDs on page 51
• Chassis Operational Mode Commands
Copyright © 2013, Juniper Networks, Inc.
187
T4000 Router Hardware Guide
188 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 18
Troubleshooting T4000 Router Hardware
Components
• T4000 Troubleshooting Resources Overview on page 189
• T4000 LED Overview on page 190
• T4000 Alarm Messages Overview on page 191
• Troubleshooting the T4000 Cooling System on page 193
• Troubleshooting the T4000 Craft Interface on page 196
• Troubleshooting the T4000 Host Subsystems on page 196
• Troubleshooting the T4000 Control Boards on page 197
• Troubleshooting the T4000 Routing Engines on page 199
• Troubleshooting the T4000 FPCs on page 200
• Troubleshooting the T4000 Power System on page 204
• Troubleshooting the T4000 PICs on page 208
• Troubleshooting the T4000 SCGs on page 208
• Troubleshooting the T4000 SIBs on page 209
T4000 Troubleshooting Resources Overview
To troubleshoot a T4000 router, you use the Junos OS command-line interface (CLI),
LCD, alarms, devices connected to the alarm relay contacts, and LEDs on both the components and craft interface.
• LEDs—When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft interface as appropriate. In addition, you can also use the component-specific LEDs on the craft interface and on the faceplate of a component to troubleshoot the router.
• LCD—When a red or yellow alarm occurs, the cause of the alarm messages is displayed on the craft interface LCD. Use the CLI to display more information about the alarm.
• Alarm devices connected to the alarm relay contact—When a red or yellow alarm occurs, it trips the corresponding alarm relay contact.
• CLI—The CLI is the primary tool for controlling and troubleshooting hardware, Junos
OS, routing protocols, and network connectivity. CLI commands display information
Copyright © 2013, Juniper Networks, Inc.
189
T4000 Router Hardware Guide from routing tables, information specific to routing protocols, and information about network connectivity derived from the ping and traceroute utilities. For information about using the CLI to troubleshoot Junos OS, see the appropriate Junos OS configuration guide.
• JTAC—If you need assistance during troubleshooting, you can contact the Juniper
Networks Technical Assistance Center (JTAC) by using the Web or by telephone. If you encounter software problems, or problems with hardware components not discussed here, contact JTAC.
Related
Documentation
• T4000 Craft Interface Description on page 23
• T4000 Craft Interface LEDs on page 25
• T4000 Connector Interface Panel (CIP) Description on page 27
• T4000 LED Overview on page 190
• T4000 Alarm Messages Overview on page 191
• Contacting Customer Support on page 353
T4000 LED Overview
• Craft Interface LEDs on page 190
• Component LEDs on page 190
Craft Interface LEDs
The craft interface displays system status messages and allows you to troubleshoot the router. See “T4000 Craft Interface LEDs” on page 25 .
LEDs on the craft interface include:
• Red and yellow alarm LEDs
• FPC LEDs
• Host subsystem LEDs
• SIB LEDs
Component LEDs
The following LEDs are located on various router components and display the status of those components:
• Control board LEDs
See “T4000 LCC-CB Control Board LEDs” on page 37
• Routing Engine LEDs
See “T4000 RE-C1800 LEDs” on page 41 .
• PIC LEDs
190 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
See T4000 Interface Module Reference .
• Power Supply LEDs
See “T4000 Six-Input DC Power Supply LEDs” on page 45 .
• SIB LEDs
See “T4000 SIB LEDs” on page 48 .
• SCG LEDs
See “T4000 SONET Clock Generators (SCGs) LEDs” on page 51 .
Related
Documentation
• T4000 Hardware Component Overview on page 13
• T4000 Troubleshooting Resources Overview on page 189
• T4000 Alarm Messages Overview on page 191
T4000 Alarm Messages Overview
When the Routing Engine detects an alarm condition, it lights the red or yellow alarm
LED on the craft interface as appropriate, trips the corresponding alarm relay contact, and reports the cause of the alarm in the craft interface LCD.
To view a more detailed description of the alarm cause, issue the show chassis alarms
CLI command: user@host> show chassis alarms
1 alarms currently active
Alarm time Class Description
2011-12-08 21:05:15 PST Minor PEM 1 Absent
There are two classes of alarm messages:
• Chassis Alarms on page 191
• Interface Alarms on page 192
Chassis Alarms
Chassis alarms Indicate a problem with a chassis component such as the cooling system or power supplies. For more information about chassis alarms for each component, see the following topics:
• Troubleshooting the T4000 Cooling System on page 193
• Troubleshooting the T4000 Craft Interface on page 196
• Troubleshooting the T4000 Control Boards on page 197
• Troubleshooting the T4000 FPCs on page 200
• Troubleshooting the T4000 Host Subsystems on page 196
• Troubleshooting the T4000 PICs on page 208
• Troubleshooting the T4000 Power System on page 204
Copyright © 2013, Juniper Networks, Inc.
191
T4000 Router Hardware Guide
• Troubleshooting the T4000 Routing Engines on page 199
• Troubleshooting the T4000 SCGs on page 208
• Troubleshooting the T4000 SIBs on page 209
Interface Alarms
Interface alarms Indicate a problem with a specific network interface, as described in
Table 29 on page 192 .
In Table 29 on page 192 , the text in the column labeled “LCD Message” appears in the
LCD. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 29: SONET/SDH Interface Alarm Messages
LCD Message CLI Message interface-name sox / x / x BERR-SD interface-name sox / x / x BERR-SF interface-name sox / x / x LAIS interface-name sox / x / x LOF interface-name sox / x / x LOL interface-name sox / x / x LOP interface-name sox / x / x LOS interface-name sox / x / x LRDI interface-name sox / x / x PAIS interface-name sox / x / x PLL interface-name sox / x / x PMIS interface-name sox / x / x PRDI interface-name sox / x / x REI interface-name sox / x / x SEF interface-name sox / x / x UNEQ interface-name sox / x / x - SONET bit error rate defect interface-name sox / x / x - SONET bit error rate fault interface-name sox / x / x - SONET line AIS interface-name sox / x / x - SONET loss of frame interface-name sox / x / x - SONET loss of light interface-name sox / x / x - SONET loss of pointer interface-name sox / x / x - SONET loss of signal interface-name sox / x / x - SONET line remote defect indicator interface-name sox / x / x - SONET path AIS interface-name sox / x / x - SONET PLL lock interface-name sox / x / x - SONET path mismatch interface-name sox / x / x - SONET path remote defect indicator interface-name sox / x / x - SONET remote error indicator interface-name sox / x / x - SONET severely errored frame interface-name sox / x / x - SONET unequipped
192 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• T4000 Craft Interface Description on page 23
Troubleshooting the T4000 Cooling System
Problem The following alarms, LEDs, and other conditions indicate a problem with the cooling system:
• A red alarm indicates that the temperature of the router exceeds the maximum
(“temperature hot”) threshold.
• Automatic shutdown of the power supplies can be caused by the temperature of the router exceeding the maximum (“temperature hot”) threshold. The control board turns off the power supplies because the router temperature exceeds the acceptable maximum.
• A red alarm indicates that a fan failed.
• A yellow alarm indicates that the router temperature exceeds the “temperature warm” threshold.
• A yellow alarm indicates that one of the fan trays was removed.
• One or more fans in a fan tray function at full speed. The control boards constantly monitor the temperatures detected by sensors on the midplane and router components, adjusting the speed of the fans as necessary. If one fan fails, the host subsystem adjusts the speed of the remaining fans to maintain proper cooling.
Table 30: T4000 Cooling System Fan Tray Alarms
Alarm
Type LCD Message CLI Message Alarm Condition Solution
Red
Yellow
Fan Failure
Fans Missing
Fan Removed fan-name Failure
Too many fans missing or failing
<fan-name> Improper <fan-name>
Improper for
Platform
A fan has failed.
Replace the fan tray.
A fan tray is missing or too many fan trays have failed.
Reinstall the fan tray in the chassis.
A fan tray is unsupported for the
T4000 router.
Replace with an appropriate fan tray.
For a list of supported fan trays, see “T4000
Cooling System
Description” on page 21 .
Incompatible rear fan tray or front fan tray detected
An incompatible fan tray is inserted into the chassis.
Replace with an appropriate fan tray.
fan-name Removed A fan tray has been removed.
Reinstall the fan tray in the chassis.
Copyright © 2013, Juniper Networks, Inc.
193
T4000 Router Hardware Guide
Table 31: T4000 Temperature Alarms
Alarm
Type
Craft Interface LCD
Message CLI Message
Red
Yellow
Temperature Hot
Sensor Failure
Temperature Warm
Alarm Condition Solution
Temperature Hot The chassis temperature exceeded the recommend hot temperature threshold. If this condition persists, the router shuts down.
• Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
Verify that the room temperature is within acceptable limits.
•
•
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Temperature sensor failure
A temperature sensor failed.
Contact JTAC.
Temperature Warm The chassis temperature exceeded the recommended warm temperature threshold.
•
•
Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
Verify that the room temperature is within acceptable limits.
•
•
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Solution To troubleshoot the cooling system:
1.
Check the red and yellow alarm LEDs on the craft interface.
2.
Find the source of the problem by looking at the craft interface display. The number of alarm conditions, as well as the source of each alarm, appears on the screen. If the craft interface display lists only one fan failure and the other fans are functioning normally, the fan is probably faulty and you need to replace the fan tray.
3.
Use the show chassis alarms command to get information about the source of an alarm condition: user@host> show chassis alarms
For information about the alarms, see Table 30 on page 193 and Table 31 on page 194 .
4.
Use the show chassis fan command to verify that the status of each fan is OK and that the output display indicates that each of the fans are Spinning at normal speed .
user@host> show chassis fan
Item Status RPM Measurement
Top Left Front fan OK 3420 Spinning at normal speed
Top Left Middle fan OK 3420 Spinning at normal speed
Top Left Rear fan OK 3450 Spinning at normal speed
Top Right Front fan OK 3420 Spinning at normal speed
Top Right Middle fan OK 3420 Spinning at normal speed
Top Right Rear fan OK 3420 Spinning at normal speed
Bottom Left Front fan OK 3420 Spinning at normal speed
194 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Bottom Left Middle fan OK 3450 Spinning at normal speed
Bottom Left Rear fan OK 3360 Spinning at normal speed
Bottom Right Front fan OK 3420 Spinning at normal speed
Bottom Right Middle fan OK 3420 Spinning at normal speed
Bottom Right Rear fan OK 3420 Spinning at normal speed
Rear Tray Top fan OK 5190 Spinning at normal speed
Rear Tray Second fan OK 5190 Spinning at normal speed
Rear Tray Third fan OK 5190 Spinning at normal speed
Rear Tray Fourth fan OK 5190 Spinning at normal speed
Rear Tray Fifth fan OK 5190 Spinning at normal speed
Rear Tray Sixth fan OK 5190 Spinning at normal speed
Rear Tray Seventh fan OK 5190 Spinning at normal speed
Rear Tray Bottom fan OK 5190 Spinning at normal speed
The fans in the fan trays are listed as follows:
• Upper front fan tray— Top Left and Top Right
• Lower front fan tray— Bottom Left and Bottom Right
• Rear fan tray— Rear
5.
Use the show chassis environment command to check the status and speed of the fans.
user@host> show chassis environment
Class Item Status Measurement
...
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed...
Top Left and Top Right refer to fans in the upper front fan tray.
Bottom Left and Bottom
Right refer to fans in the lower front fan tray.
Rear refers to the fans in the rear fan tray.
Related
Documentation
• T4000 Cooling System Description on page 21
• Replacing a T4000 Lower Front Fan Tray on page 236
• Replacing a T4000 Upper Front Fan Tray on page 238
• Replacing a T4000 Rear Fan Tray on page 240
• Replacing a T4000 Front Air Filter on page 218
Copyright © 2013, Juniper Networks, Inc.
195
T4000 Router Hardware Guide
• Replacing a T4000 Rear Air Filter on page 220
Troubleshooting the T4000 Craft Interface
Problem The following alarms, LEDs, and other conditions indicate a problem with the craft interface:
• The router is powered on, but none of the LEDs on the craft interface are lit.
• A yellow alarm indicates that the craft interface has failed.
In Table 32 on page 196 , the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 32: Chassis Alarm Messages for the Craft Interface
Alarm Type LCD Message CLI Message
Yellow Craft Failure Craft Failure
Solution To troubleshoot the craft interface:
1.
Check the LEDs on the craft interface. If the router is powered on but none of the LEDs are lit, reseat the craft interface to make sure that it is installed properly. See “Replacing a T4000 Craft Interface” on page 234 .
2.
Use the CLI to check for alarms. Use the show chassis alarms command.
Related
Documentation
• T4000 Craft Interface Description on page 23
• T4000 Craft Interface LEDs on page 25
Troubleshooting the T4000 Host Subsystems
Problem The following alarms and LEDs indicate a problem with a host subsystem control board and Routing Engine:
• The red host subsystem FAIL LED on the craft interface is lit.
• The green host subsystem OK LED on the craft interface is not lit.
• A red alarm indicates that the host subsystem has been removed.
• A yellow alarm indicates that the host subsystem has failed.
In Table 33 on page 197 , the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
196 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Table 33: Chassis Alarm Messages for Host Subsystems
Alarm Type LCD Message CLI Message
Host host-number Removed Host host-number Removed Red
Yellow Host host-number Failure Host host-number Failure
Solution To troubleshoot the host subsystems:
1.
Check the LEDs on the faceplate of each control board and Routing Engine.
2.
Check the LEDs on the craft interface.
3.
If the red HOST0 FAIL or HOST1 FAIL LED is lit on the craft interface, look at the LCD
4.
Use the show chassis alarms command to check for alarms.
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Control Board Description on page 36
• T4000 LCC-CB on page 37
• T4000 LCC-CB Control Board LEDs on page 37
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
• Maintaining the T4000 Host Subsystem on page 182
• Replacing a T4000 LCC-CB on page 228
• Replacing a T4000 Routing Engine on page 267
Troubleshooting the T4000 Control Boards
Problem The following alarms and LEDs indicate a problem with a control board:
• A red alarm indicates that the control board has failed or has been removed.
• A yellow alarm indicates that the Ethernet switch in the control board has failed.
• The yellow FAIL LED on the control board faceplate is lit.
• The green OK LED on the control board faceplate is not lit.
• The red host subsystem FAIL LED on the craft interface is lit.
• The green host subsystem OK LED on the craft interface is not lit.
In Table 34 on page 198 , the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Copyright © 2013, Juniper Networks, Inc.
197
T4000 Router Hardware Guide
Table 34: T4000 Chassis Alarm Messages for the Control Boards
Alarm Type LCD Message CLI Message Alarm Condition
Red
Yellow
CB cb-number
Removed
CB cb-number
Failure
CB cb-number
Ethernet Switch
Failure
Solution
CB cb-number
Removed
A control board has been removed.
CB cb-number Failure A control board has failed.
CB cb-number Ethernet
Switch Failure
The control board’s
Ethernet switch has failed.
Reinstall the control board.
Replace the control board.
Replace the control board.
CB cb-number Unsupported
CB cb-number Not
Supported an unsupported control board is installed.
Install a supported control board. See “T4000 Control
Board Description” on page 36 .
Solution To troubleshoot the control boards:
1.
Check the LEDs on the faceplate of each control board.
2.
Check the LEDs on the craft interface.
3.
Use the show chassis alarms command to view the alarms.
4.
Use the show chassis environment cb command to check the status of the control boards. Verify that the control boards are Online .
user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1809 mV
2.5 V 2496 mV
3.3 V 3295 mV
4.6 V 4687 mV
5.0 V 5042 mV
12.0 V 11985 mV
3.3 V bias 3277 mV
8.0 V bias 7472 mV
GBUS Revision 40
FPGA Revision 7
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Control Board Description on page 36
• T4000 LCC-CB on page 37
• T4000 LCC-CB Control Board LEDs on page 37
• Maintaining the T4000 Host Subsystem on page 182
• Replacing a T4000 LCC-CB on page 228
198 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Troubleshooting the T4000 Routing Engines
Problem The following alarms, LEDs, and other conditions indicate a problem with a Routing
Engine:
• The show chassis routing-engine LED on the Routing Engine faceplate is lit steadily red, indicating that the Routing Engine has failed.
• An alarm indicates that a host subsystem has been removed or failed.
Solution To troubleshoot the Routing Engines:
1.
Use the show chassis routing-engine command.
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 34 degrees C / 93 degrees F
DRAM 2048 Mbytes
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
Start time 2002-01-22 05:21:31 UTC
Uptime 10 days, 16 hours, 4 minutes, 52 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00
Routing Engine status:
Slot 1:
Current state Empty
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Control Board Description on page 36
• T4000 LCC-CB on page 37
• T4000 LCC-CB Control Board LEDs on page 37
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
• Maintaining the T4000 Host Subsystem on page 182
• Replacing a T4000 LCC-CB on page 228
• Replacing a T4000 Routing Engine on page 267
Copyright © 2013, Juniper Networks, Inc.
199
T4000 Router Hardware Guide
Troubleshooting the T4000 FPCs
Problem The following LEDs indicate a problem with an FPC:
• The red FAIL LED above the FPC on the craft interface is lit.
• The green FAIL LED above the FPC on the craft interface is lit.
Table 35: Chassis Alarm Messages for the FPCs
Alarm Type LCD Message CLI Message Alarm Condition Solution
Red FPC fpc-slot misconfig FPC fpc-slot misconfig The FPC is not supported, and will not come online.
Remove the unsupported
FPC. See “T4000 FPCs
Supported” on page 34 .
Solution To troubleshoot an FPC:
1.
Look at the display on the craft interface to check the status of the FPC and the PICs that are plugged into it.
2.
Use the show chassis fpc command to check the status of an FPC.
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Empty
1 Empty
2 Empty
3 Empty
4 Online 58 11 0 2816 30 27
5 Empty
6 Online 52 13 0 2816 29 27
7 Online 60 12 0 2816 29 27
For more detailed output, add the detail option.
user@host> show chassis fpc detail
Slot 4 information:
State Online
Temperature 58 degrees C / 136 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-12-08 21:10:44 PST
Uptime 1 day, 13 hours, 50 minutes, 14 seconds
Slot 6 information:
State Online
Temperature 52 degrees C / 125 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-12-08 21:10:50 PST
Uptime 1 day, 13 hours, 50 minutes, 8 seconds
Slot 7 information:
State Online
Temperature 60 degrees C / 140 degrees F
200 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-12-09 01:33:46 PST
Uptime 1 day, 9 hours, 27 minutes, 12 seconds
For detailed output for a specific FPC, specify a slot number ( 5 ), which is optional: user@host> show chassis fpc detail 5
Slot 5 information:
State Online
Temperature 53 degrees C / 127 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-10-24 09:54:43 UTC
Uptime 14 days, 19 hours, 58 minutes, 13 seconds
3.
Verify that the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight. Use a screwdriver to check that the screws inside the ejector handles are tight.
4.
Use the show chassis fabric fpcs command to check the status of an FPC.
user@host> show chassis fabric fpcs
Fabric management FPC state:
FPC #4
PFE #0
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
PFE #1
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
FPC #6
PFE #0
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
Copyright © 2013, Juniper Networks, Inc.
201
T4000 Router Hardware Guide
202
PFE #1
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
FPC #7
PFE #0
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
PFE #1
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
5.
Use the show chassis fabric reachability command to check the status of an FPC.
user@host> show chassis fabric reachability
Fabric reachability status: Enabled destinations reachable
Fabric reachability detection:
Unreachable destinations : Present on 0 FPCs
Detected on : 2011-12-10 11:17:43 PST
6.
Use the show chassis environment fpc command to check the status of an FPC.
user@host> show chassis environment fpc
FPC 4 status:
State Online
Fan Intake 34 degrees C / 93 degrees F
Fan Exhaust 58 degrees C / 136 degrees F
PMB 49 degrees C / 120 degrees F
LMB0 65 degrees C / 149 degrees F
LMB1 61 degrees C / 141 degrees F
LMB2 39 degrees C / 102 degrees F
PFE1 LU2 72 degrees C / 161 degrees F
PFE1 LU0 44 degrees C / 111 degrees F
PFE0 LU0 79 degrees C / 174 degrees F
XF1 58 degrees C / 136 degrees F
XF0 63 degrees C / 145 degrees F
XM1 40 degrees C / 104 degrees F
XM0 75 degrees C / 167 degrees F
Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
PFE0 LU1 75 degrees C / 167 degrees F
PFE0 LU2 71 degrees C / 159 degrees F
PFE1 LU1 40 degrees C / 104 degrees F
Power 1
1.0 V 997 mV
1.2 V bias 1195 mV
1.8 V 1782 mV
2.5 V 2494 mV
3.3 V 3296 mV
3.3 V bias 3286 mV
12.0 V A 10446 mV
12.0 V B 10437 mV
Power 2
0.9 V 901 mV
0.9 V PFE0 919 mV
0.9 V PFE1 904 mV
1.0 V PFE0 991 mV
1.0 V PFE1 970 mV
1.1 V 1096 mV
1.5 V_0 1495 mV
1.5 V_1 1479 mV
Power 3
1.0 V PFE0 1003 mV
1.0 V PFE1 1004 mV
1.0 V PFE0 * 993 mV
1.0 V PFE1 * 996 mV
1.8 V PFE 0 1794 mV
1.8 V PFE 1 1794 mV
2.5 V 2450 mV
12.0 V 11638 mV
Power 4
1.0 V PFE0 LU0 1003 mV
1.0 V PFE1 LU0 1001 mV
1.0 V PFE1 LU2 1001 mV
1.0 V PFE0 LU0 * 995 mV
1.0 V PFE1 LU0 * 995 mV
1.0 V PFE1 LU2 * 995 mV
12.0 V 11614 mV
12.0 V C 11658 mV
Power (Base/PMB/MMB)
LMB0 VDD2V5 2504 mV
LMB0 VDD1V8 1782 mV
LMB0 VDD1V5 1496 mV
LMB0 PFE0 LU0 AVDD1V0 1002 mV
LMB0 PFE0 LU0 VDD1V0 1008 mV
LMB0 VDD12V0 10624 mV
LMB1 VDD2V5 2484 mV
LMB1 VDD1V8 1784 mV
LMB1 VDD1V5 1480 mV
LMB1 PFE0 LU2 AVDD1V0 1000 mV
LMB1 PFE0 LU2 VDD1V0 1006 mV
LMB1 VDD12V0 10704 mV
LMB2 VDD2V5 2492 mV
LMB2 VDD1V8 1794 mV
LMB2 VDD1V5 1492 mV
LMB2 PFE1 LU1 AVDD1V0 998 mV
LMB2 PFE1 LU1 VDD1V0 1006 mV
LMB2 VDD12V0 10576 mV
PMB 1.05v 1049 mV
PMB 1.5v 1500 mV
PMB 2.5v 2500 mV
Copyright © 2013, Juniper Networks, Inc.
203
T4000 Router Hardware Guide
PMB 3.3v 3300 mV
Bus Revision 80
Related
Documentation
• T4000 Craft Interface LEDs on page 25
• T4000 FPC Description on page 30
• Maintaining T4000 FPCs on page 184
• Replacing a T4000 FPC on page 242
Troubleshooting the T4000 Power System
Problem The following alarms, LEDs, and other conditions indicate a problem with the power system:
• If all power supplies have failed, the system temperature might have exceeded the threshold, causing the system to shut down.
• Table 36 on page 206 lists alarms for the power system, including the solution.
• Table 37 on page 207 lists abnormal LED states for the power supplies, including the solution.
Solution 1.
Check the display on the craft interface to determine the source of a yellow or red alarm (see Table 36 on page 206 ). Junos OS constantly updates the screen with status information for each component.
NOTE: On the display and in the CLI, the power supplies are referred to as PEM0 and PEM1 , from top to bottom.
If the system temperature exceeds the threshold, Junos OS shuts down all power supplies so that no status is displayed.
Junos OS also can shut down one of the power supplies for other reasons.
In that case, the remaining power supply assumes the load, and you can still view the system status through the CLI or display.
2.
Issue the show chassis alarms command to check for power system alarms. See
Table 36 on page 206 .
3.
Check the LEDs on each six-input DC power supply faceplate. See Table 37 on page 207 .
4.
Use the show chassis environment pem command.
user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature 34 degrees C / 93 degrees F
DC Input: OK
Voltage(V) Current(A) Power(W) Load(%)
INPUT 0 53.500 7.437 397 52
INPUT 1 53.750 10.812 581 77
204 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
INPUT 2 53.125 9.562 507 67
INPUT 3 53.625 11.125 596 79
INPUT 4 53.750 9.875 530 70
INPUT 5 53.250 9.500 505 67
DC Output Voltage(V) Current(A) Power(W) Load(%)
FPC 0 0.000 0.000 0 0
FPC 1 0.000 0.000 0 0
FPC 2 0.000 0.000 0 0
FPC 3 0.000 0.000 0 0
FPC 4 55.375 9.562 529 70
FPC 5 0.062 0.000 0 0
FPC 6 55.062 9.000 495 66
FPC 7 55.437 9.000 498 66
SCG/CB/SIB 55.375 15.375 851 70
FAN 49.000 7.875 385 51
5.
Verify that the customer site circuit breaker for each input has the proper current rating.
NOTE: All inputs on a DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all inputs on a DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed
A/B feed redundancy for the system.
6.
Verify that the DC power cables from the power source to the router are not damaged.
If the insulation is cracked or broken, immediately replace the DC power cable .
7.
Connect the power supply to a different power source with a new DC power cable. If the power supply DC OK LED still does not light, the power supply is the source of the problem. Replace the power supply with a spare. If the DC OK LED on the installed spare still does not light—The replaced power supply might also be faulty. To return it for replacement, see “Contacting Customer Support” on page 353 .
8.
If you cannot determine the cause of the problem or need additional assistance, see
“Contacting Customer Support” on page 353 .
In Table 36 on page 206 , the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Copyright © 2013, Juniper Networks, Inc.
205
T4000 Router Hardware Guide
Table 36: Power System Chassis Alarms
Alarm Type LCD Message CLI Message
Red PEM pem-number
High Temp
Alarm Condition Solution
PEM pem-number High Temp The power supply is not receiving enough airflow to maintain proper temperature.
Check that the power supply fans are running and that the air filters are clean to be sure they are functioning and providing sufficient airflow through the power supply.
If there is not sufficient airflow, replace the air filters.
Use the show chassis environment pem command to view the temperature.
Yellow
PEM pem-number
Input Fail
PEM pem-number
Not OK
PEM pem-number
Improper
PEM pem-number
Absent
PEM pem-number
Inputs Cfg
PEM pem-number Input Failure
PEM pem-number Not OK
PEM pem-number Improper for
Platform
PEM pem-number Absent
A feed to the power supply has failed.
The power supply experienced a failure.
Replace the power supply.
The power supply is not supported.
A power supply is not installed.
Check the input feed connectivity and voltage levels. Voltage range should be between –40 V and
–72 V.
Install a supported power supply.
Install a supported power supply in the appropriate slot.
PEM pem-number
Configuration
Mismatch-number of inputs
The number of installed cables does not match the number of cables configured in the set chassis pem feeds command.
Ensure that the number of cables connected to the power supply is correct and that the number of cables connected matches the number of feeds configured on the router with the set chassis pem feeds command. Correct one or both of the following:
• add or remove cables connected to the power supply
• reconfigure the number of feeds and the input current by using the set chassis pem feeds and set chassis pem input-current commands
206 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Table 37: Troubleshooting PDU LEDs
LED Color State Condition
INPUT
PRESENT
DC OK
Green
Blue
OVER TEMP Yellow
Off
Off
Blinking steadily
On
Solution
The input is not connected, not receiving voltage or is under –40 V.
•
•
Verify that the customer site circuit breakers are switched on. If the customer site circuit breakers are off, switch them on.
Verify that the input is receiving power within the supported voltage range.
If the customer circuit breakers are switched on but the input is not receiving power, switch off the customer site circuit breakers, and reinstall the DC power source cables.
The power switch on the power supply faceplate is off, the power supply is not functioning normally, or the input voltage is not present or is under –40 V.
Verify that the customer site circuit breakers are switched on, and that the input is receiving power within the supported voltage range.
•
•
If the customer site circuit breakers are off, switch them on.
If the customer circuit breakers are switched on but the input is not receiving power, switch off the customer site circuit breakers, and reinstall the DC power source cables.
The input is okay, but the power supply might not be properly inserted, or there is a fault (such as insufficient airflow or faulty output).
The LED blinks when the power supply is initializing; but if it continues to blink, verify that the power supply is installed properly and that the power supply switch is in the on position.
If the LED continues to blink, replace the power supply.
The power supply is shut down because of excessive internal tempature.
Check the power supply fan and air filters to be sure they are functioning and providing sufficient airflow through the power supply and that the power supply is operating within the specified ambient temperature.
Wait approximately 30 to 60 minutes and turn on the power supply. If the over temperature condition persists, replace the power supply.
Use the show chassis environment pem command to view the temperature.
Related
Documentation
• T4000 Power System Description on page 43
• T4000 Six-Input DC Power Supply LEDs on page 45
• Maintaining the T4000 Power System on page 186
• Replacing a T4000 Six-Input DC Power Supply on page 257
• Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 264
• Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 265
Copyright © 2013, Juniper Networks, Inc.
207
T4000 Router Hardware Guide
Troubleshooting the T4000 PICs
Problem A PIC LED lit red indicates a problem with the PIC.
Solution To troubleshoot a PIC:
1.
Check the status of each port on a PIC. Look at the LEDs located on the PIC faceplate.
For information about the meaning of LED states on different PICs, see the T4000
Interface Module Reference .
2.
Check the status of a PIC, issuing the following CLI command. The PIC slots in the
FPC are numbered from 0 through 3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online FPC Type 4-ES
PIC 0 Online 4x 10GE (LAN/WAN) XFP
PIC 1 Online 4x 10GE (LAN/WAN) XFP
Slot 3 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 12x10GE (LAN/WAN) SFPP
Slot 4 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 12x10GE (LAN/WAN) SFPP
Slot 5 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 12x10GE (LAN/WAN) SFPP
Slot 6 Online FPC Type 5-3D
PIC 0 Online 24x10GE (LAN/WAN) SFPP
PIC 1 Online 24x10GE (LAN/WAN) SFPP
Slot 7 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 1x100GE
Related
Documentation
• T4000 PIC Description on page 42
• Replacing a T4000 PIC on page 253
Troubleshooting the T4000 SCGs
Problem The following alarms and LEDs indicate a problem with an SCG:
• The yellow FAIL LED on the SCG faceplate is lit.
• The green OK LED on the SCG faceplate is not lit.
• A red alarm indicates that the SCG has failed or has been removed.
• A yellow alarm indicates that the SCG is not online.
In Table 38 on page 209 , the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
208 Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
Table 38: Chassis Alarm Messages for the SCGs
Alarm Type LCD Message CLI Message
Red
Yellow
SCG SCG-number
Failure
SCG SCG-number
Removed
SCG
SCG
SCG-number Failure
SCG-number Removed
SCG SCG-number Not
Online
SCG SCG-number Not Online
Solution To troubleshoot the SCGs:
1.
Check the LEDs on the faceplate of each SCG.
2.
Check the LEDs on the craft interface.
3.
Use the show chassis environment scg command.
user@host> show chassis environment scg
SCG 0 status:
State Online - Master clock
Temperature 31 degrees C / 87 degrees F
Power:
GROUND 0 mV
3.3 V 3310 mV
5.0 V 5052 mV
5.6 V 5689 mV
1.8 V bias 1782 mV
3.3 V bias 3306 mV
5.0 V bias 4989 mV
8.0 V bias 8336 mV
GBUS Revision 40
FPGA Revision 1.6
4.
Use the CLI to check for alarms—Issue the show chassis alarms command to view the alarms.
Related
Documentation
• T4000 SONET Clock Generators (SCGs) Description on page 49
• T4000 SONET Clock Generators (SCGs) LEDs on page 51
• Maintaining the T4000 SCGs on page 187
• Replacing a T4000 SCG on page 277
Troubleshooting the T4000 SIBs
Problem The following alarms and LEDs indicate a problem with a SIB:
• A red alarm indicates that the SIB failed or has been removed or that a spare SIB has failed or has been removed.
• The red FAIL LED on the SIB faceplate is lit.
Copyright © 2013, Juniper Networks, Inc.
209
T4000 Router Hardware Guide
210
• The green OK LED on the SIB faceplate is not lit.
In Table 39 on page 210 the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 39: T4000 Chassis Alarm Messages for SIBs
Alarm Type LCD Message CLI Message
Red SIB sib-number Failure SIB sib-number Fault
SIB sib-number Removed SIB sib-number Absent
Solution To troubleshoot the T4000 SIBs:
1.
Check the LEDs on the faceplate of each SIB.
2.
Check the LEDs on the craft interface.
3.
Use the CLI to check for alarms.
• Issue the show chassis alarms command to view the alarms.
4.
Use the show chassis sibs command.
user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 14 hours, 21 minutes, 52 seconds
2 Online 1 day, 14 hours, 21 minutes, 36 seconds
3 Online 1 day, 14 hours, 21 minutes, 19 seconds
4 Online 1 day, 14 hours, 21 minutes, 3 seconds
5.
Use the show chassis fabric sibs command.
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0
plane state: S_SPARE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #4
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
6.
Use the show chassis environment sib command.
user@host> show chassis environment sib
SIB 0 status:
State Online - Standby
Temperature 50 degrees C / 122 degrees F
Power
8.0 V bias 8232 mV
3.3 V bias 3280 mV
0.9 V bias 910 mV
1.1 V bias 1094 mV
1.5 V bias 1486 mV
2.5 V bias 2528 mV
9.0 V 9012 mV
3.3 V 3300 mV
XF0 0.92 V 926 mV
XF0 1.0 V LDO 994 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1792 mV
XF1 0.92 V 922 mV
XF2 0.92 V 922 mV
Copyright © 2013, Juniper Networks, Inc.
211
T4000 Router Hardware Guide
212
XF3 1.0 V 1000 mV
1.2 V 1192 mV
XF1 1.0 V LDO 996 mV
XF2 1.0 V LDO 996 mV
XF3 1.0 V LDO 994 mV
XF1 1.8 V 1792 mV
XF2 1.8 V 1796 mV
XF3 1.8 V 1786 mV
1.5 V 1486 mV
SW 3.3 V 3292 mV
SIB 1 status:
State Online
Temperature 49 degrees C / 120 degrees F
Power
8.0 V bias 8280 mV
3.3 V bias 3296 mV
0.9 V bias 910 mV
1.1 V bias 1096 mV
1.5 V bias 1494 mV
2.5 V bias 2524 mV
9.0 V 9000 mV
3.3 V 3296 mV
XF0 1.0 V 1008 mV
XF0 1.0 V LDO 998 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1804 mV
XF1 1.0 V 1004 mV
XF2 1.0 V 1000 mV
XF3 1.0 V 1002 mV
1.2 V 1194 mV
XF1 1.0 V LDO 998 mV
XF2 1.0 V LDO 996 mV
XF3 1.0 V LDO 998 mV
XF1 1.8 V 1808 mV
XF2 1.8 V 1794 mV
XF3 1.8 V 1786 mV
1.5 V 1492 mV
SW 3.3 V 3304 mV
SIB 2 status:
State Online
Temperature 49 degrees C / 120 degrees F
Power
8.0 V bias 8244 mV
3.3 V bias 3296 mV
0.9 V bias 908 mV
1.1 V bias 1098 mV
1.5 V bias 1490 mV
2.5 V bias 2520 mV
9.0 V 9000 mV
3.3 V 3296 mV
XF0 1.0 V 1004 mV
XF0 1.0 V LDO 998 mV
PCIe SW 1.0 V 994 mV
XF0 1.8 V 1790 mV
XF1 1.0 V 1004 mV
XF2 1.0 V 1002 mV
XF3 1.0 V 1004 mV
1.2 V 1198 mV
XF1 1.0 V LDO 1002 mV
XF2 1.0 V LDO 998 mV
XF3 1.0 V LDO 1000 mV
Copyright © 2013, Juniper Networks, Inc.
Chapter 18: Troubleshooting T4000 Router Hardware Components
XF1 1.8 V 1794 mV
XF2 1.8 V 1790 mV
XF3 1.8 V 1800 mV
1.5 V 1478 mV
SW 3.3 V 3308 mV
SIB 3 status:
State Online
Temperature 48 degrees C / 118 degrees F
Power
8.0 V bias 8280 mV
3.3 V bias 3300 mV
0.9 V bias 910 mV
1.1 V bias 1098 mV
1.5 V bias 1506 mV
2.5 V bias 2520 mV
9.0 V 8988 mV
3.3 V 3304 mV
XF0 1.0 V 1004 mV
XF0 1.0 V LDO 1000 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1808 mV
XF1 1.0 V 1000 mV
XF2 1.0 V 1002 mV
XF3 1.0 V 1002 mV
1.2 V 1194 mV
XF1 1.0 V LDO 998 mV
XF2 1.0 V LDO 996 mV
XF3 1.0 V LDO 996 mV
XF1 1.8 V 1794 mV
XF2 1.8 V 1794 mV
XF3 1.8 V 1792 mV
1.5 V 1484 mV
SW 3.3 V 3300 mV
SIB 4 status:
State Online
Temperature 50 degrees C / 122 degrees F
Power
8.0 V bias 8268 mV
3.3 V bias 3296 mV
0.9 V bias 910 mV
1.1 V bias 1098 mV
1.5 V bias 1500 mV
2.5 V bias 2492 mV
9.0 V 9012 mV
3.3 V 3312 mV
XF0 1.0 V 1004 mV
XF0 1.0 V LDO 1002 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1790 mV
XF1 1.0 V 1004 mV
XF2 1.0 V 1006 mV
XF3 1.0 V 1004 mV
1.2 V 1196 mV
XF1 1.0 V LDO 1006 mV
XF2 1.0 V LDO 1002 mV
XF3 1.0 V LDO 1000 mV
XF1 1.8 V 1800 mV
XF2 1.8 V 1800 mV
XF3 1.8 V 1796 mV
1.5 V 1486 mV
SW 3.3 V 3312 mV
Copyright © 2013, Juniper Networks, Inc.
213
T4000 Router Hardware Guide
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000 Craft Interface LEDs on page 25
• T4000 SIB LEDs on page 48
• Replacing a T4000-SIB on page 279
214 Copyright © 2013, Juniper Networks, Inc.
CHAPTER 19
Replacing T4000 Router Hardware
Components
• T4000 Field-Replaceable Units on page 216
• Tools and Parts Required for Replacing T4000 Hardware Components on page 217
• Replacing a T4000 Front Air Filter on page 218
• Replacing a T4000 Rear Air Filter on page 220
• Replacing the T4000 Alarm Relay Wires on page 224
• Replacing a T4000 Console or Auxiliary Cable on page 224
• Replacing a T4000 Management Ethernet Cable on page 226
• Replacing a T4000 LCC-CB on page 228
• Replacing a T4000 CIP on page 231
• Replacing a T4000 Craft Interface on page 234
• Replacing a T4000 Lower Front Fan Tray on page 236
• Replacing a T4000 Upper Front Fan Tray on page 238
• Replacing a T4000 Rear Fan Tray on page 240
• Replacing a T4000 FPC on page 242
• Replacing T4000 Host Subsystem Components on page 248
• Replacing a T4000 PIC on page 253
• Replacing a T4000 Six-Input DC Power Supply on page 257
• Replacing a T4000 DC Power Supply Cable on page 262
• Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 264
• Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 265
• Replacing a T4000 Routing Engine on page 267
• Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine on page 270
• Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine on page 273
• Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine on page 276
• Replacing a T4000 SCG on page 277
Copyright © 2013, Juniper Networks, Inc.
215
T4000 Router Hardware Guide
• Replacing a T4000-SIB on page 279
• Replacing a T4000 TXP-LCC-3D SIB on page 282
T4000 Field-Replaceable Units
Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime. The router uses the following types of FRUs:
• Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering off the router or disrupting the routing functions.
• Hot-pluggable FRUs—You can remove and replace these components without powering down the router, but the routing functions of the system are interrupted when the component is removed.
Before you replace a component in the host subsystem, you must take the host subsystem offline.
Table 40 on page 216 lists the FRUs for the router.
Table 40: Field-Replaceable Units
Hot-Removable and Hot-Insertable FRUs Hot-Pluggable FRUs
Air filters Connector Interface Panel (CIP)
Flexible PIC Concentrators (FPCs)
Front and rear fan trays
Nonredundant control boards
Master control board (if nonstop active routing is not configured)
PICs
Redundant power supplies
Nonredundant Routing Engine
Master Routing Engine (if nonstop active routing is not configured) Backup SONET Clock Generator (SCG)
Switch Interface Boards (SIBs)
Backup control board
Master control board (if nonstop active routing is configured)
Master SONET Clock Generator (SCG)
Nonredundant SONET Clock Generator (SCG)
Backup Routing Engine
Master Routing Engine (if nonstop active routing is configured)
Related
Documentation
• T4000 Hardware Component Overview on page 13
• T4000 Component Redundancy on page 15
• Tools and Parts Required for Replacing T4000 Hardware Components on page 217
216 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Tools and Parts Required for Replacing T4000 Hardware Components
To replace hardware components, you need the tools and parts listed in
Table 41 on page 217 .
Table 41: Tools and Parts Required for Component Replacement
Components Tool or part
All
Air filter (front or rear)
CIP
Electrostatic discharge (ESD) grounding wrist strap
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Craft interface
Control board
DC power supply
DC power supply cable
Fan tray (front or rear)
FPC
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Phillips (+) screwdrivers, numbers 1 and 2
7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts.
Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 in-lb (5.0 Nm).
7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts.
Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 in-lb (5.0 Nm).
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Blank panel (if component is not reinstalled)
Electrostatic bag or antistatic mat
Copyright © 2013, Juniper Networks, Inc.
217
T4000 Router Hardware Guide
Table 41: Tools and Parts Required for Component
Replacement
(continued)
Components Tool or part
PIC Phillips (+) screwdrivers, numbers 1 and 2
Rubber safety cap for fiber-optic PICs or fiber-optic PIC cables
Flat-blade (–) screwdriver for Type 1 PICs
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Routing Engine Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Serial cable to AUXILIARY or CONSOLE Routing
Engine port
Flat-blade (–) screwdriver
SIB
SCG
Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Phillips (+) screwdrivers, numbers 1 and 2
Related
Documentation
• Returning a Hardware Component to Juniper Networks, Inc. on page 354
• Tools and Parts Required to Remove Components from a T4000 Router on page 355
Replacing a T4000 Front Air Filter
1.
Removing the T4000 Front Air Filter on page 218
2.
Installing the T4000 Front Air Filter on page 219
Removing the T4000 Front Air Filter
The front air filter, located below the FPC card cage in the front of the chassis, installs horizontally. The front air filter weighs approximately 1 lb (0.5 kg). The air filters are hot-insertable and hot-removable.
To remove the front air filter (see Figure 89 on page 219 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the cable management system, and remove the cables from the tray. Arrange the cables so that they do not block the front of the
218 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the cable management system. Lift it up and outward to lock it in place to access the air filter.
4.
Loosen the captive screws on the corners of the air filter faceplate.
5.
Grasp the handles, and pull the air filter straight out of the chassis.
6.
Remove the filter element from the air filter frame (see Figure 90 on page 219 ).
Figure 89: Removing the Front Air Filter
Figure 90: Replacing the Front Filter Element
Installing the T4000 Front Air Filter
To install the front air filter (see Figure 91 on page 220 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Insert the filter element into the air filter frame.
3.
Grasp the air filter by the handles on its faceplate, and slide it straight into the chassis.
4.
Tighten the captive screws on the corners of the faceplate.
Copyright © 2013, Juniper Networks, Inc.
219
T4000 Router Hardware Guide
5.
Unlock the cable management system, and lower it to the fully lowered position.
6.
Rearrange the PIC cables in the cable management system.
Figure 91: Installing the Front Air Filter
Related
Documentation
• Preventing T4000 Electrostatic Discharge Damage on page 296
• T4000 Cooling System Description on page 21
• Troubleshooting the T4000 Cooling System on page 193
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Maintaining the T4000 Air Filters on page 180
Replacing a T4000 Rear Air Filter
1.
Removing a Rear T4000 Air Filter on page 220
2.
Installing the T4000 Rear Air Filter on page 222
Removing a Rear T4000 Air Filter
The rear air filter is located at the left rear edge of the chassis. The rear air filter weighs less than 1 lb (0.5 kg).
To remove the rear air filter:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws at the top, center, and bottom of the air filter, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the air filter cover by the captive screws, and pull firmly to remove the cover and honeycomb assembly from the chassis (see Figure 92 on page 221 ).
4.
Press the filter element inward until it clears the hooks at the top and bottom of the air filter slot, then push it to the left to unseat it.
5.
Move the tabs on the filter element to a horizontal position.
6.
Grasp the tabs on the filter element, and carefully pull it straight out from the chassis
(see Figure 93 on page 222 ).
220 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Figure 92: Removing the Rear Air Filter
Copyright © 2013, Juniper Networks, Inc.
221
T4000 Router Hardware Guide
Figure 93: Removing the Rear Air Filter Element
Installing the T4000 Rear Air Filter
To install the rear air filter (see Figure 94 on page 223 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Holding the filter by the tabs, carefully push the filter all the way into the air filter slot.
3.
Holding the filter all the way in, push it to the right side of the slot until it is held in place behind the hooks.
4.
Move the tabs to a vertical position.
5.
Place the right edge of the honeycomb against the flange of the air filter slot.
6.
Line up the holes at the top, center, and bottom of the honeycomb with the pins in the slot, and press the honeycomb into place.
222 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
7.
Replace the air filter cover.
8.
Firmly tighten the captive screws at the top, center, and bottom of the filter cover to secure it to the chassis, using a Phillips (+) screwdriver, number 2.
Figure 94: Installing the Rear Air Filter
Related
Documentation
• Preventing T4000 Electrostatic Discharge Damage on page 296
• T4000 Cooling System Description on page 21
• Troubleshooting the T4000 Cooling System on page 193
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Maintaining the T4000 Air Filters on page 180
Copyright © 2013, Juniper Networks, Inc.
223
T4000 Router Hardware Guide
Replacing the T4000 Alarm Relay Wires
1.
Removing the T4000 Alarm Relay Wires on page 224
2.
Installing the T4000 Alarm Relay Wires on page 224
Removing the T4000 Alarm Relay Wires
To remove the wires connected to an alarm-reporting device:
1.
Disconnect the existing wire at the external device.
2.
Using a 2.5-mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact.
3.
Using the 2.5-mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block, and insert replacement wires. Tighten the screws to secure the wire.
Installing the T4000 Alarm Relay Wires
To connect replacement wires to an alarm-reporting device:
1.
Prepare the required length of replacement wire with a gauge between 28 AWG and
14 AWG (0.08 and 2.08 mm
2
).
2.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
3.
Attach the other end of the wires to the external device.
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Connecting the T4000 Router to an External Alarm-Reporting Device on page 114
• T4000 Alarm Relay Contact Wire Specifications on page 350
Replacing a T4000 Console or Auxiliary Cable
1.
Removing a T4000 Console or Auxiliary Cable on page 224
2.
Installing a T4000 Console or Auxiliary Cable on page 226
Removing a T4000 Console or Auxiliary Cable
To remove a serial cable connected to a management console or auxiliary device (see
Figure 95 on page 225 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Turn off the power to the console or auxiliary device.
3.
Unscrew the screws that secure the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary.
224 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
4.
Pull the cable connector straight out of the port.
5.
Disconnect the cable from the console or auxiliary device.
Figure 95: DB-9 Port on the CIP
Copyright © 2013, Juniper Networks, Inc.
225
T4000 Router Hardware Guide
Installing a T4000 Console or Auxiliary Cable
The AUXILIARY port and CONSOLE port on the CIP both accept an RS-232 (EIA-232_ serial cable with DB-9 connectors.
To connect a management console or auxiliary device:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Connect one end of the replacement cable into the appropriate CONSOLE or AUXILIARY port. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing
Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing Engine slot ( RE1 ).
3.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
4.
Plug the other end of the cable into the device's serial port.
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
• T4000 Routing Engine Interface Cable Specifications on page 350
• DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 351
Replacing a T4000 Management Ethernet Cable
1.
Removing a T4000 Management Ethernet Cable on page 226
2.
Installing a T4000 Management Ethernet Cable on page 227
Removing a T4000 Management Ethernet Cable
1.
Press the tab on the connector, and pull the connector straight out of the ETHERNET port.
Figure 96 on page 226 shows the connector.
2.
Disconnect the cable from the network device.
Figure 96: Ethernet Cable Connectors
226 Copyright © 2013, Juniper Networks, Inc.
Figure 97: Ethernet Port on CIP
Chapter 19: Replacing T4000 Router Hardware Components
Installing a T4000 Management Ethernet Cable
1.
Plug one end of the replacement cable into the appropriate ETHERNET port. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot ( RE1 ).
2.
Plug the other end of the cable into the network device.
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Connecting the T4000 Router to a Management Ethernet Device on page 118
• T4000 Routing Engine Interface Cable Specifications on page 350
Copyright © 2013, Juniper Networks, Inc.
227
T4000 Router Hardware Guide
• RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 351
Replacing a T4000 LCC-CB
The router can have up to two LCC-CBs. They are located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each LCC-CB weighs approximately 5 lb (2.3 kg).
1.
Removing a T4000 LCC-CB on page 228
2.
Installing a T4000 LCC-CB on page 229
Removing a T4000 LCC-CB
CAUTION: Before you replace a control board, you must take the host subsystem offline. The backup control board is hot-removable and hot-insertable. If the control board to be replaced is associated with the
Routing Engine currently functioning as the master Routing Engine, switch the master to the backup before removing the control board. If there is only one host subsystem, taking the host subsystem offline shuts down the router.
To remove an LCC-CB (see Figure 98 on page 229 ):
1.
Take the host subsystem offline.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on both sides of the LCC-CB faceplate.
5.
Flip the ejector handles outward to unseat the LCC-CB.
6.
Grasp the ejector handles, and slide the LCC-CB about halfway out of the chassis.
7.
Place one hand underneath the LCC-CB to support it, and slide it completely out of the chassis.
8.
Place the LCC-CB on the antistatic mat.
9.
If you are not replacing the LCC-CB now, install a blank panel over the empty slot.
228 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Figure 98: Removing an LCC-CB
Installing a T4000 LCC-CB
To install an LCC-CB (see Figure 99 on page 231 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that the two configuration switches on the faceplate of the LCC-CB are set correctly for a standalone T4000 router before you install the LCC-CB:
• The M/S configuration switch must be set to S .
• The CHASSIS ID configuration switch must be set to 0 .
3.
Carefully align the sides of the LCC-CB with the guides inside the chassis.
4.
Slide the LCC-CB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles, and press them inward to seat the LCC-CB.
6.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
7.
Verify that the LCC-CB is functioning normally:
• Check the LEDs on the LCC-CB faceplate. The green OK LED should light steadily a few minutes after the LCC-CB is installed. If power is applied to the Routing Engine and its corresponding LCC-CB is functioning normally, the LCC-CB comes online automatically.
If the FAIL LED is lit steadily, remove and install the LCC-CB again. If the FAIL LED still lights steadily, the LCC-CB is not functioning properly. Contact your customer support representative.
Copyright © 2013, Juniper Networks, Inc.
229
T4000 Router Hardware Guide
• Use the show chassis environment cb command to check the status of the LCC-CB.
show chassis environment cb
CB 0 status:
State Online Master
Temperature 38 degrees C / 100 degrees F
Power 1
1.8 V 1800 mV
2.5 V 2501 mV
3.3 V 3288 mV
3.3 V bias 3296 mV
4.6 V 4682 mV
5.0 V 4923 mV
8.0 V bias 7755 mV
12.0 V 11887 mV
Power 2
1.0 V 989 mV
1.2 V 1186 mV
3.3 V RE 3321 mV
Bus Revision 51
FPGA Revision 5
CB 1 status:
State Online Standby
Temperature 40 degrees C / 104 degrees F
Power 1
1.8 V 1802 mV
2.5 V 2518 mV
3.3 V 3297 mV
3.3 V bias 3274 mV
4.6 V 4693 mV
5.0 V 4959 mV
8.0 V bias 7746 mV
12.0 V 11897 mV
Power 2
1.0 V 991 mV
1.2 V 1200 mV
3.3 V RE 3315 mV
Bus Revision 51
FPGA Revision 5
230 Copyright © 2013, Juniper Networks, Inc.
Figure 99: Installing an LCC-CB
Chapter 19: Replacing T4000 Router Hardware Components
Related
Documentation
• T4000 Control Board Description on page 36
• T4000 LCC-CB on page 37
• T4000 LCC-CB Control Board LEDs on page 37
• Replacing T4000 Host Subsystem Components on page 248
Replacing a T4000 CIP
The CIP is located to the left side of the FPC card cage. It houses the Routing Engine interface ports, which accept connections to external management and alarm-reporting devices.
The CIP is hot-pluggable. It weighs approximately 8 lb (3.6 kg). When the CIP is removed, you cannot control or communicate with the router using an external device.
1.
Removing a T4000 CIP on page 231
2.
Installing a T4000 CIP on page 233
Removing a T4000 CIP
To remove the CIP (see Figure 100 on page 232 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Disconnect any external devices connected to the CIP.
Copyright © 2013, Juniper Networks, Inc.
231
T4000 Router Hardware Guide
3.
Loosen the captive screws at the top and bottom of the CIP faceplate.
4.
Grasp the handle on the CIP faceplate and carefully pull the CIP straight out of the chassis.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
Figure 100: Removing the CIP
232 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Installing a T4000 CIP
To install the CIP (see Figure 101 on page 234 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the CIP handle with one hand and hold the bottom edge of the CIP with the other hand to support its weight.
NOTE: The components on the CIP are on the left side of the board, unlike the components of an FPC, which are on the right side. Verify that the components are on the left before inserting the CIP.
3.
Insert the CIP into the leftmost slot of the FPC card cage, carefully aligning the top and bottom of the CIP with the guides in the card cage.
4.
Carefully push the CIP straight into the chassis until it contacts the midplane.
5.
Tighten the screws at the top and bottom of the CIP faceplate.
6.
Reattach any external devices connected to the CIP.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
7.
To verify that the CIP is installed correctly, plug an Ethernet cable into the Ethernet port on the CIP. If the host module is operational, the ACTIVE LED blinks to indicate
Ethernet activity. If you can run the CLI, the CIP is installed correctly.
Copyright © 2013, Juniper Networks, Inc.
233
T4000 Router Hardware Guide
Figure 101: Installing the CIP
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Replacing the T4000 Alarm Relay Wires on page 224
• Replacing a T4000 Console or Auxiliary Cable on page 224
• Replacing a T4000 Management Ethernet Cable on page 226
Replacing a T4000 Craft Interface
1.
Removing the T4000 Craft Interface on page 235
2.
Installing the T4000 Craft Interface on page 235
234 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Removing the T4000 Craft Interface
CAUTION: Before you remove the craft interface, remove the upper front fan tray. See “Replacing a T4000 Upper Front Fan Tray” on page 238 .
To remove the craft interface, see Figure 102 on page 235 .
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Completely loosen the screws at the four corners of the craft interface.
3.
Insert the blade of a flat-blade screwdriver into the slot on one side of the craft interface, then gently pry that side out from the chassis.
4.
Insert the blade of a flat-blade screwdriver into the slot on the other side of the craft interface, then gently pry that side out from the chassis.
5.
Grasp the craft interface by the top and bottom edges and carefully pull it straight out of the chassis.
Figure 102: Removing the Craft Interface
T Series
ACO/LT
FAIL
FPC0
OK
FAIL
FPC1
OK
FAIL
MENU
ENTER
FAIL
FPC3
OK
FAIL
FPC4
OK
FAIL
FPC5
OK
FAIL OK
MASTER
HOST0
FAIL
OK
HOST1
MASTER
SIB0
FAIL
OK
SIB1
SIB2
SIB3
SIB4
FAIL
FPC6
OK
FAIL
FPC7
OK
Installing the T4000 Craft Interface
To install the craft interface (see Figure 103 on page 236 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasping the craft interface by the top and bottom edges, press it into place.
3.
Tighten the screws at the corners of the craft interface.
NOTE: When you install the craft interface in an operating router, allow several minutes for the LEDs on the craft interface to reflect the current state of the router.
Copyright © 2013, Juniper Networks, Inc.
235
T4000 Router Hardware Guide
After you install the replacement craft interface, immediately reinstall the upper front fan tray. See “Replacing a T4000 Upper Front Fan Tray” on page 238 .
Figure 103: Installing a Replacement Craft Interface
T Series
FAIL FPC0
OK
FAIL
ACO/LT
FPC1
OK
MENU
ENTER
FAIL
FANTRAY-T4000
FAIL
FPC3
OK
FAIL
FPC4
OK
FAIL
FPC5
OK
FAIL OK
MASTER
HOST0
FAIL
OK
HOST1
MASTER
SIB0
FAIL
SIB1
OK
SIB2
SIB3
SIB4
FAIL
FPC6
OK
FAIL
FPC7
OK
Related
Documentation
• T4000 Craft Interface Description on page 23
• Troubleshooting the T4000 Craft Interface on page 196
Replacing a T4000 Lower Front Fan Tray
The lower front fan tray is located below the front air filter. Each front fan tray weighs about 20.4 lb (9.3 kg). The fan trays are hot-insertable and hot-removable. The upper and lower fan trays are interchangeable with each other.
NOTE: Ensure that at any given time only one front fan tray is replaced. Do
NOT replace both the front lower and upper fans simultaneously.
1.
Removing the T4000 Lower Front Fan Tray on page 236
2.
Installing the T4000 Lower Front Fan Tray on page 237
Removing the T4000 Lower Front Fan Tray
1.
Attach an electrostatic discharge (ESD) grounding strap to your wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the front cable management system and remove the cables from the tray. Arrange the cables so that they do not block the front cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
236 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
3.
Simultaneously pull the two releases on the front cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
4.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see “Maintaining T4000 PICs” on page 184 .
5.
Loosen the captive screws on the corners of the fan tray faceplate.
6.
Grasp the handles, and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
7.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 104: Removing the T4000 Lower Front Fan Tray
FANTRAY-T4000
Installing the T4000 Lower Front Fan Tray
To install a lower front fan tray:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles, and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Unlock the front cable management system and lower it to the fully lowered position.
5.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see “Maintaining T4000 PICs” on page 184 .
Copyright © 2013, Juniper Networks, Inc.
237
T4000 Router Hardware Guide
Figure 105: Installing the T4000 Lower Front Fan Tray
FANTRAY-T4000
Related
Documentation
• T4000 Cooling System Description on page 21
• Troubleshooting the T4000 Cooling System on page 193
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Maintaining the T4000 Fan Trays on page 181
Replacing a T4000 Upper Front Fan Tray
The upper front fan tray is located above the FPC card cage. Each front fan tray weighs about 20.4 lb (9.3 kg). The fan trays are hot-insertable and hot-removable. The upper and lower fan trays are interchangeable with each other.
NOTE: Ensure that at any given time only one front fan tray is replaced. Do
NOT replace both the front lower and upper fans simultaneously.
1.
Removing the T4000 Upper Front Fan Tray on page 238
2.
Installing the T4000 Upper Front Fan Tray on page 239
Removing the T4000 Upper Front Fan Tray
To remove an upper front fan tray (see Figure 106 on page 239 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
238 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 106: Removing an Upper Front Fan Tray
FANTRAY-T4000
T Series
FANTRAY-T4000
FANTRA
Y-T4000
Installing the T4000 Upper Front Fan Tray
To install an upper front fan tray (see Figure 107 on page 240 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles, and insert it straight into the chassis.
Copyright © 2013, Juniper Networks, Inc.
239
T4000 Router Hardware Guide
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
Figure 107: Installing an Upper Front Fan Tray
T Series
FANTRAY-T4000
FANTRAY-T4000
Related
Documentation
• T4000 Cooling System Description on page 21
• Troubleshooting the T4000 Cooling System on page 193
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Maintaining the T4000 Fan Trays on page 181
Replacing a T4000 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray contains eight fans, and is not interchangeable with the front fan trays. The rear fan tray must be used in conjunction with the front fan trays. The rear fan tray weighs about 10 lb (4.5 kg).
CAUTION: To maintain proper cooling, do not operate the routing node with the rear fan tray removed for more than one minute.
1.
Removing the T4000 Rear Fan Tray on page 240
2.
Installing the T4000 Rear Fan Tray on page 241
Removing the T4000 Rear Fan Tray
To remove the rear fan tray (see Figure 108 on page 241 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
240 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
4.
Wait for the fans to stop spinning.
5.
After the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 108: Removing the FAN-R-TXP-3D-LCC Rear Fan Tray
Installing the T4000 Rear Fan Tray
To install a replacement rear fan tray (see Figure 109 on page 242 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles, and insert it straight into the chassis.
3.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
Copyright © 2013, Juniper Networks, Inc.
241
T4000 Router Hardware Guide
Figure 109: Installing the Rear Fan Tray
Related
Documentation
• T4000 Cooling System Description on page 21
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Maintaining the T4000 Fan Trays on page 181
• Troubleshooting the T4000 Cooling System on page 193
• Preventing T4000 Electrostatic Discharge Damage on page 296
Replacing a T4000 FPC
The FPCs are hot-insertable and hot-removable. When you remove an FPC, the router continues to function, although the PIC interfaces installed on the FPC being removed no longer function.
242 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
The router holds up to eight FPCs, which are installed vertically in the front of the router.
An empty FPC weighs approximately 25 lb (11.3 kg), and an FPC with PICs installed can weigh up to 33.5 lb (15.1 kg).
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 9 lb (4.2 kg).
1.
Removing a T4000 FPC on page 243
2.
Installing a T4000 FPC on page 245
Removing a T4000 FPC
To remove an FPC (see Figure 110 on page 245 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Before removing an FPC, record its location in the chassis so that you can reinstall each FPC in the correct slot.
4.
Use one of the following methods to take the FPC offline:
• Press and hold the FPC online/offline button. The green OK LED next to the button begins to blink. Hold the button down until the LED goes out. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
5.
Disconnect the cables from the PICs installed in the FPC. If a PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap. Arrange the disconnected cables in the cable management system, to prevent the cables from developing stress points.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
Copyright © 2013, Juniper Networks, Inc.
243
T4000 Router Hardware Guide
6.
If necessary, remove each installed PIC from the FPC.
7.
After you remove each PIC, immediately place it on an antistatic mat or in an electrostatic bag.
Do not stack components on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
8.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
9.
Grasp the handles, and slide the FPC straight out of the card cage halfway.
10.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 33.5 lb (15.1 kg)—as you slide the FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
11.
If you are not reinstalling an FPC into the emptied FPC slot within a short time, install a blank FPC panel over the slot to maintain proper airflow in the FPC card cage.
CAUTION: After removing an FPC from the chassis, wait at least 30 seconds before reinserting it, removing an FPC from a different slot, or inserting an FPC into a different slot.
244 Copyright © 2013, Juniper Networks, Inc.
Figure 110: Removing an FPC
Chapter 19: Replacing T4000 Router Hardware Components
T-1600 FPC4
Installing a T4000 FPC
CAUTION: The FPC power connector is located in the corner where the bottom and the connector edges meet. If a power connector prong becomes bent, it no longer aligns with the female connector on the midplane, and the FPC no longer functions.
To install an FPC (see Figure 111 on page 247 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place the FPC on an antistatic mat.
3.
Take each PIC to be installed in the replacement FPC out of its electrostatic bag and identify the slot on the FPC where it will be connected.
Copyright © 2013, Juniper Networks, Inc.
245
T4000 Router Hardware Guide
4.
Verify that each fiber-optic PIC has a rubber safety cap covering the PIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each PIC into the appropriate slot on the FPC. For information about installing a PIC, see “Installing a T4000 PIC” on page 255 ..
6.
Locate the slot in the FPC card cage in which you plan to install the FPC.
7.
Inspect the slot in the FPC card cage to verify that there are no missing or bent pins on the midplane.
8.
Inspect the FPC to verify that the connectors are not misaligned or damaged.
9.
Orient the FPC vertically with the component side facing to the right. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
10.
Carefully align the connector edge of the FPC with the appropriate empty slot in the chassis.
11.
Lift the FPC into place, and carefully align the bottom and top of the FPC with the guides inside the card cage.
246 Copyright © 2013, Juniper Networks, Inc.
Figure 111: Installing an FPC
Chapter 19: Replacing T4000 Router Hardware Components
Do not bend or damage prongs on power connector
12.
Gently rest the bottom edge of the FPC on the bottom edge of the slot opening, making contact a short distance forward of the power connector.
CAUTION: Take care not to bend or otherwise damage the power connector prongs.
13.
Slowly slide the FPC into the slot until you feel resistance.
14.
Align the ejector handles on the FPC faceplate in a position close to horizontal.
15.
Simultaneously turn both ejector handles clockwise until you cannot turn them farther.
16.
If any of the PICs on the FPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
Copyright © 2013, Juniper Networks, Inc.
247
T4000 Router Hardware Guide
17.
Insert the appropriate cable into the cable connector ports on each PIC on the FPC.
Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
18.
Use one of the following methods to bring the FPC online:
• Press and hold the FPC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the FPC again, removing an FPC from a different slot, or inserting an FPC in a different slot.
You can also verify correct FPC and PIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands.
Replacing T4000 Host Subsystem Components
1.
Taking the T4000 Host Subsystem Offline on page 248
2.
Replacing a Control Board or Routing Engine Component on page 252
Taking the T4000 Host Subsystem Offline
Before you replace a control board, a Routing Engine, and some Routing Engine components, you must take the host subsystem offline. The host subsystem is taken offline and brought online as a unit. Normally, if two host subsystems are installed in the router, RE0 functions as the master and RE1 functions as the backup.
248 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to each Routing Engine.
NOTE: For information about high availability features, configuring graceful switchover and nonstop active routing, see the Junos OS High Availability
Library for Routing Devices.
Table 42 on page 249 explains the effect of taking the host subsystem offline.
Table 42: Effect of Taking the Host Subsystem Offline
Type of Host
Subsystem Effect of taking the Host Subsystem Offline
Nonredundant host subsystem
The router shuts down.
Backup host subsystem
The functioning of the router is not interrupted. The backup host subsystem is hot-removable and hot-insertable.
Copyright © 2013, Juniper Networks, Inc.
249
T4000 Router Hardware Guide
Table 42: Effect of Taking the Host Subsystem Offline
(continued)
Type of Host
Subsystem Effect of taking the Host Subsystem Offline
Master host subsystem
The backup host subsystem becomes the master. The backup Routing
Engine assumes Routing Engine functions. The master host subsystem is hot-pluggable. Removal or failure of the master Routing Engine affects forwarding and routing based on the high availability configuration:
• Dual Routing Engines without any high availability features enabled—Traffic is interrupted while the Packet Forwarding Engine is reinitialized. All kernel and forwarding processes are restarted. When the switchover to the new master Routing Engine is complete, routing convergence takes place and traffic is resumed.
• Graceful Routing Engine switchover (GRES) is enabled—Graceful
Routing Engine switchover preserves interface and kernel information.
Traffic is not interrupted. However, graceful Routing Engine switchover does not preserve the control plane. Neighboring routers detect that the router has restarted and react to the event in a manner prescribed by individual routing protocol specifications. To preserve routing without interruption during a switchover, graceful Routing Engine switchover must be combined with nonstop active routing.
NOTE: Graceful Routing Engine switchover (GRES) is supported on Junos
OS Release 12.1R2 and later for T4000 routers.
• Nonstop active routing is enabled (graceful Routing Engine switchover must be configured for nonstop active routing to be enabled)—Nonstop active routing supports Routing Engine switchover without alerting peer nodes that a change has occurred. Nonstop active routing uses the same infrastructure as graceful Routing Engine switchover to preserve interface and kernel information. However, nonstop active routing also preserves routing information and protocol sessions by running the routing protocol process (rpd) on both Routing Engines. In addition, nonstop active routing preserves TCP connections maintained in the kernel.
•
Nonstop active routing is supported on Junos OS Release 12.1R2 and later for T4000 routers,
Graceful restart is configured—Graceful restart provides extensions to routing protocols so that neighboring helper routers restore routing information to a restarting router. These extensions signal neighboring routers about the graceful restart and prevent the neighbors from reacting to the router restart and from propagating the change in state to the network during the graceful restart period. Neighbors provide the routing information that enables the restarting router to stop and restart routing protocols without causing network reconvergence. Neighbors are required to support graceful restart. The routing protocol process
(rpd) restarts. A graceful restart interval is required. For certain protocols, a significant change in the network can cause graceful restart to stop.
250 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
To take a host subsystem offline:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of the two following methods:
• Check the Routing Engine LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Use the show chassis routing-engine command to determine which Routing Engine is the master. In this example, the master Routing Engine in Slot 0 is designated
Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 38 degrees C / 100 degrees F
CPU temperature 56 degrees C / 132 degrees F
DRAM 8960 MB
Memory utilization 20 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 4 percent
Interrupt 1 percent
Idle 95 percent
Model RE-DUO-1800
Serial ID P737F-002693
Start time 2011-12-08 21:04:20 PST
Uptime 1 day, 13 hours, 22 minutes, 57 seconds
Last reboot reason Router rebooted after a normal shutdown.
Load averages: 1 minute 5 minute 15 minute
0.04 0.05 0.01
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 38 degrees C / 100 degrees F
CPU temperature 53 degrees C / 127 degrees F
DRAM 8960 MB
Memory utilization 17 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 1 percent
Idle 98 percent
Model RE-DUO-1800
Serial ID P737F-002587
Start time 2011-12-08 20:57:51 PST
Uptime 1 day, 13 hours, 29 minutes, 11 seconds
Last reboot reason Router rebooted after a normal shutdown.
2.
If the host subsystem is functioning as the master, switch it to backup using the CLI command: user@host> request chassis routing-engine master switch
Copyright © 2013, Juniper Networks, Inc.
251
T4000 Router Hardware Guide
3.
To halt the router: user@host> request system halt
If two Routing Engines are installed, also issue the command on the backup Routing
Engine. Wait until a message appears on the console confirming that the operating system has halted.
The command shuts down the Routing Engine cleanly, so its state information is preserved.
NOTE: The SIBs might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
4.
On the console or other management device connected to the other Routing Engine, enter CLI operational mode and issue the following command.
user@host> request chassis cb offline slot n n is 0 or 1 for the slot number of the host subsystem being taken offline.
5.
Verify that the control board is offline: user@host> show chassis environment cb 0
Replacing a Control Board or Routing Engine Component
NOTE: To replace a solid-state disk or CompactFlash card, you must power off the Routing Engine.
After you take the host subsystem offline, you can replace the following host subsystem components:
• Replacing a T4000 LCC-CB on page 228
• Replacing a T4000 Routing Engine on page 267
• Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine on page 270
• Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine on page 273
• Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine on page 276
Related
Documentation
• T4000 Host Subsystem Description on page 35
• Preventing T4000 Electrostatic Discharge Damage on page 296
• request system halt
• Chassis Operational Mode Commands
252 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Replacing a T4000 PIC
1.
Removing a T4000 PIC on page 253
2.
Installing a T4000 PIC on page 255
Removing a T4000 PIC
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs approximately 2 lb (0.9 kg).
To remove a PIC (see Figure 112 on page 255 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
2.
Attach an electrostatic discharge ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Use one of the following methods to take the PIC offline:
• Issue the following CLI command:
• user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
Press and hold the online/offline button until the status LED on the PIC goes out
(about 5 seconds). The label for the status LED varies for each PIC. See the T4000
Interface Module Reference for more information about the PIC LEDs.
For a Type 4 or Type 5 PIC, use a narrow-ended tool that fits inside the opening that leads to the button.
4.
Label the cables connected to the PIC so that you can later reconnect each cable to the correct PIC.
5.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight
Copyright © 2013, Juniper Networks, Inc.
253
T4000 Router Hardware Guide as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Type 4 or Type 5 PIC—To unseat the PIC, twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate counterclockwise to unseat the PIC.
8.
Slide the PIC out of the FPC card carrier, and place it in the electrostatic bag or on the antistatic mat.
9.
If you are not reinstalling a PIC into the emptied PIC slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the FPC card cage.
254 Copyright © 2013, Juniper Networks, Inc.
Figure 112: Removing a PIC
Chapter 19: Replacing T4000 Router Hardware Components
Installing a T4000 PIC
To install a PIC (see Figure 113 on page 257 ).
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
3.
Align the notches in the connector at the rear of the PIC with the notches in the PIC slot in the FPC, and then slide the PIC in until it lodges firmly in the FPC.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the bottom of the PIC.
Copyright © 2013, Juniper Networks, Inc.
255
T4000 Router Hardware Guide
4.
Type 4 or Type 5 PICs—To secure the PIC to the FPC faceplate, twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate counterclockwise to unseat the PIC.
5.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Insert the appropriate cables into the cable connectors on the PIC.
7.
Arrange each cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Use one of the following methods to bring the PIC online:
• Press the PIC offline/online button until the status LED on the PIC lights green. For a Type 4 or Type 5 PIC, use a narrow-ended tool that fits inside the opening that leads to the button.
For more information about the PIC LEDs, see the T4000 Interface Module Reference .
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command.
256 Copyright © 2013, Juniper Networks, Inc.
Figure 113: Installing a PIC
Chapter 19: Replacing T4000 Router Hardware Components
Replacing a T4000 Six-Input DC Power Supply
1.
Removing a T4000 Six-Input DC Power Supply on page 258
2.
Installing a T4000 Six-Input DC Power Supply on page 260
Copyright © 2013, Juniper Networks, Inc.
257
T4000 Router Hardware Guide
Removing a T4000 Six-Input DC Power Supply
To remove a six-input DC power supply:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
2.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
Figure 114: DC Power Supply
258
3.
Using a 7/16-in. (11 mm) nut driver, remove the nuts and washers from the terminal studs (see Figure 115 on page 258 ).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Figure 115: Disconnecting Power Cables from the DC Power Supply
Cable lug
Terminal studs
Locking washer
Nut
4.
Remove the cable lugs from the terminal studs.
Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
5.
Loosen the captive screws on the cable restraints on the right edge of the power supply faceplate.
6.
Carefully move the power cables out of the way.
7.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
8.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
9.
Grasp the handle on the power supply faceplate, and pull firmly. Slide it halfway out of the chassis (see Figure 116 on page 259 ).
CAUTION: Each DC power supply weighs approximately 39.7 lb (18.0 kg).
Be prepared to support the full weight of the power supply as you remove it from the router.
10.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
Figure 116: Removing a DC Power Supply
Copyright © 2013, Juniper Networks, Inc.
WARNING: Do not touch the power connectors on the rear of the power supply (see Figure 117 on page 260 ). They can contain dangerous voltages.
259
T4000 Router Hardware Guide
Figure 117: Rear of the Power Supply Showing Midplane Connectors
Installing a T4000 Six-Input DC Power Supply
Each DC power supply weighs approximately 39.7 lb (18.0 kg). To install a six-input DC power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Using both hands, slide the power supply into the chassis until you feel resistance
(see Figure 118 on page 260 ).
Figure 118: Inserting the DC Power Supply into the Chassis
260
4.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
5.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
6.
Verify that a licensed electrician has attached cable lugs to the power cables that you supply.
7.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
8.
Remove the nut and washer from each power terminal stud.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
9.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the negative (–) DC source power cable lug to the –48V (input) terminal.
b.
Attach the positive (+) DC source power cable lug to the RTN (return) terminal.
Secure the cable lugs to the terminal studs, first with a washer, then with a nut (see
Figure 119 on page 261 ). Use a 7/16-in. (11 mm) nut driver to tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Figure 119: Attaching the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
10.
Loosen the captive screws on the cable restraint on the right edge of the power supply faceplate.
11.
Route the DC power cables through the cable restraint.
12.
Tighten the cable restraint captive screws to hold the power cables in place.
13.
Verify that the power cabling is correct, that the power cables do not touch or block access to other hardware components, and that they do not drape where people could trip on them.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
Copyright © 2013, Juniper Networks, Inc.
261
T4000 Router Hardware Guide
15.
Switch on the customer site circuit breakers to provide voltage to the DC power source cables.
16.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving power.
17.
Switch the power switch on the power supply to the ON position ( | ). The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
18.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly.
Related
Documentation
• T4000 Power System Description on page 43
• T4000 Six-Input DC Power Supply LEDs on page 45
• Maintaining the T4000 Power System on page 186
• Troubleshooting the T4000 Power System on page 204
Replacing a T4000 DC Power Supply Cable
1.
Removing a T4000 DC Power Supply Cable on page 262
2.
Installing a T4000 DC Power Supply Cable on page 263
Removing a T4000 DC Power Supply Cable
To remove a DC power supply cable from a six-input DC power supply:
1.
Switch off the customer site circuit breakers for all the cables attached to the power supply. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
2.
Remove the power cable from the external DC power source.
3.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
4.
Remove the nut and washer from the terminal stud on the power supply (see
Figure 120 on page 263 ). Use a 7/16-in. (11 mm) nut driver.
262 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Figure 120: Disconnecting the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
5.
Remove the cable lug from the terminal stud on the power supply.
6.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
7.
Carefully move the power cable out of the way.
Installing a T4000 DC Power Supply Cable
To install a DC power supply cable on a six-input DC power supply:
1.
Locate a DC power cable that meets the specifications for the power supply.
CAUTION: A licensed electrician must attach a cable lug to the power cable that you supply. A cable with an incorrectly attached lug can damage the router.
2.
Route the power cable through the appropriate cable restraint.
3.
Attach the lug on the DC source power cable to the terminal stud.
a.
Attach a negative (–) DC source power cable lug to the –48V (input) terminals.
b.
Attach a positive (+) DC source power cable lug to the RET (return) terminals.
Secure the cable lug to the terminal stud, first with a washer, then with a nut (see
Figure 121 on page 264 ). Use a 7/16-in. (11-mm) nut driver to tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Copyright © 2013, Juniper Networks, Inc.
263
T4000 Router Hardware Guide
Figure 121: Connecting the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
4.
Tighten the cable restraint captive screw or screws to hold the power cable in place.
5.
Replace the clear plastic cover over the terminal studs on the faceplate.
6.
Verify that the DC source power cabling is correct, that the power cable is not touching or blocking access to router components, and that it does not drape where people could trip on it.
7.
Attach the other end of the power cable to the external DC power source.
8.
Switch on the customer site circuit breakers.
9.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving voltage.
10.
Switch the power switch on the power supply to the ON position ( | ). The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
11.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly.
Related
Documentation
• T4000 Power System Description on page 43
• T4000 Six-Input DC Power Supply LEDs on page 45
• Maintaining the T4000 Power System on page 186
• Troubleshooting the T4000 Power System on page 204
Replacing a T4000 Six-Input DC Power Supply Front Air Filter
1.
Removing a T4000 Six-Input DC Power Supply Front Air Filter on page 265
2.
Installing a T4000 Six-Input DC Power Supply Front Air Filter on page 265
264 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Removing a T4000 Six-Input DC Power Supply Front Air Filter
To remove a six-input DC power supply :
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the filter cover on the power supply faceplate, and pull it straight off the power supply.
3.
Remove the air filter.
Installing a T4000 Six-Input DC Power Supply Front Air Filter
To install a six-input DC power supply front filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Install a new filter element.
3.
Press the filter cover straight onto the power supply faceplate until all four sides click into place.
Replacing a T4000 Six-Input DC Power Supply Side Air Filter
1.
Removing a T4000 Six-Input DC Power Supply Side Air Filter on page 265
2.
Installing a T4000 Six-Input DC Power Supply Side Air Filter on page 266
Removing a T4000 Six-Input DC Power Supply Side Air Filter
To remove a six-input DC power supply side air filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screw.
3.
Slide the air filter cover until the two lances leave the sheet metal.
4.
Remove the air filter cover hooks from the rectangle holes in the sheet metal.
5.
Remove the side air filter element from the air filter cover.
Copyright © 2013, Juniper Networks, Inc.
265
T4000 Router Hardware Guide
Figure 122: Removing the Power Supply Side Air Filter
Air filter cover
Air filter element
Installing a T4000 Six-Input DC Power Supply Side Air Filter
To install a six-input DC power supply side air filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Install a new side filter element into the side air filter cover.
3.
Insert the side air filter cover hooks into the rectangle holes in the sheet metal.
4.
Slide the side air filter cover back into the power supply faceplate. The two lances insert into the sheet metal.
5.
Tighten the captive screw.
Figure 123: Installing the Power Supply Side Air Filter
266
Air filter element
Air filter cover
Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Replacing a T4000 Routing Engine
1.
Removing a T4000 Routing Engine on page 267
2.
Installing a T4000 Routing Engine on page 268
Removing a T4000 Routing Engine
The router can have one or two Routing Engines. They are located in the upper rear of the chassis in the slots marked RE0 and RE1 . Each Routing Engine can weigh up to
2.4 lb (1.1 kg). The backup Routing Engine is hot-removable and hot-insertable.
CAUTION: Before you replace a Routing Engine, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router. If the Routing Engine to be replaced is currently functioning as the master Routing Engine, switch it to be the backup before removing it.
To remove a Routing Engine (see Figure 125 on page 268 ):
1.
Take the host subsystem offline.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Loosen the captive screws on the corners of the Routing Engine cover.
5.
Grasp the Routing Engine cover by its edges, and pull it free from the chassis (see
Figure 124 on page 268 ).
6.
If applicable, loosen the screws on the extractor handles at either end of the Routing
Engine faceplate, using a Phillips screwdriver.
7.
Press the red tabs on the ejector handles on both sides of the Routing Engine faceplate.
8.
Flip the ejector handles outward to unseat the Routing Engine.
9.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
10.
Place one of your hands underneath the Routing Engine to support it, and slide it completely out of the chassis.
11.
Place the Routing Engine on the antistatic mat.
12.
If you are not replacing the Routing Engine now, reinstall the Routing Engine cover, and tighten the screws on the corners of the cover to secure it to the chassis.
Copyright © 2013, Juniper Networks, Inc.
267
T4000 Router Hardware Guide
Figure 124: Removing the Routing Engine Cover
Figure 125: Removing a T4000 C1800 Routing Engine
Installing a T4000 Routing Engine
To install a Routing Engine (see Figure 126 on page 269 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, press the red tabs and flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it. With the other hand, grasp one of the ejector handles on the faceplate.
4.
Carefully align the sides of the Routing Engine with the guides inside the chassis.
5.
Slide the Routing Engine into the chassis until you feel resistance, then press the
Routing Engine's faceplate until it engages the midplane connectors.
6.
Press both the ejector handles inward to seat the Routing Engine.
The Routing Engine might require several minutes to boot.
268 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
7.
If applicable, tighten the screws on the extractor handles, by using a Phillips screwdriver. Be sure to tighten the screws enough to seat the Routing Engine properly.
8.
Press the Routing Engine cover into place, then tighten the captive screws on the corners of the cover to secure it to the chassis (see Figure 127 on page 269 ).
Figure 126: Installing a Routing Engine
Figure 127: Reinstalling the Routing Engine Cover
Related
Documentation
• T4000 Host Subsystem Description on page 35
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
• Maintaining the T4000 Routing Engines on page 182
Copyright © 2013, Juniper Networks, Inc.
269
T4000 Router Hardware Guide
• Troubleshooting the T4000 Routing Engines on page 199
• Replacing T4000 Host Subsystem Components on page 248
• Preventing T4000 Electrostatic Discharge Damage on page 296
Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine
1.
Preparing to Replace a CompactFlash Card in a T4000 RE-C1800 Routing
Engine on page 270
2.
Removing a CompactFlash Card from a T4000 RE-C1800 Routing Engine on page 271
3.
Installing a CompactFlash Card into a T4000 RE-C1800 Routing Engine on page 271
4.
Copying Junos OS to the CompactFlash Card in a T1600 RE-C1800 Routing
Engine on page 272
Preparing to Replace a CompactFlash Card in a T4000 RE-C1800 Routing Engine
The CompactFlash card is located in the slot labeled CF on the Routing Engine faceplate.
To prepare to replace the CompactFlash card:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of these methods:
• Check the Host Subsystem LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Check the MASTER LED on the control board. If the blue MASTER LED is lit, the host subsystem is functioning as the master.
• Issue the show chassis routing-engine command: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
In these examples, the Routing Engine in slot 0 is designated Master in the Current state field
2.
If the host subsystem is functioning as the master, switch it to backup. Issue the request chassis routing-engine master switch command.
3.
From the master Routing Engine, power down the backup Routing Engine. Issue the request system power-off other-routing-engine command.
270 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Removing a CompactFlash Card from a T4000 RE-C1800 Routing Engine
The CompactFlash card is located in the slot labeled CF on the Routing Engine faceplate.
To remove the CompactFlash card (see Figure 128 on page 271 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Verify that the Online , DISK1 , and CF LEDs on the backup Routing Engine faceplate are off.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the corners of the cover over the Routing Engine slots.
5.
Remove the cover from the Routing Engine slots.
CAUTION: Do not remove the cover if any of the LEDs are lit.
6.
Press the eject button on the right side of the CompactFlash card slot to release the
CompactFlash card.
7.
The CompactFlash card pops partially out of the slot. Grasp the card and pull it completely out of the slot.
8.
Place the CompactFlash card on the antistatic mat.
Figure 128: Removing a CompactFlash Card
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF CF
S
K
D
I
1
D
S
I
K
2
USB
Offline
Online
Installing a CompactFlash Card into a T4000 RE-C1800 Routing Engine
To install a CompactFlash card (see Figure 129 on page 272 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Insert the CompactFlash card into the CompactFlash card slot on the Routing Engine, with the logo facing up.
CAUTION: Be sure to insert the CompactFlash card with the label facing up. Inserting the CompactFlash card incorrectly might damage the Routing
Engine.
Copyright © 2013, Juniper Networks, Inc.
271
T4000 Router Hardware Guide
3.
Press the card firmly all the way into the slot.
4.
Reinstall the Routing Engine cover. Using a Phillips (+) screwdriver, number 2, tighten the screws on the corners of the cover to secure it to the Routing Engine.
5.
From the master Routing Engine, power on the Routing Engine. Issue the request system power-on other-routing-engine command.
NOTE: After you replace a CompactFlash card, the Routing Engine boots from the solid-state disk (SSD). You may get an error message and be prompted for a keystroke. After you press the keystroke, it might take up to 10 minutes for the Routing Engine to reset and for the router to boot from the SSD.
Figure 129: Installing a CompactFlash Card
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
S
K
D
I
CF 1
K
2
D
S
I
USB
Offline
Online
Reset
Copying Junos OS to the CompactFlash Card in a T1600 RE-C1800 Routing Engine
After installing the CompactFlash card for the first time, you must copy the software from the Routing Engine's solid-state disk (SSD) to the CompactFlash card.
To copy software to the CompactFlash card:
1.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode and copy the currently running and active file system partitions on the router to standby partitions on the CompactFlash card. Issue the request system snapshot partition command.
2.
Wait until a message appears on the console confirming that the snapshot partition procedure is complete.
3.
Issue the request system reboot command to reboot the router's software.
4.
Issue the show system boot-messages command to verify that the CompactFlash card is listed as the primary boot device. The output lists the devices mounted. The
CompactFlash card is located at ad0 .
Related
Documentation
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
• T4000 Craft Interface LEDs on page 25
• Preventing T4000 Electrostatic Discharge Damage on page 296
272 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
• Chassis Operational Mode Commands
• System Software Operational Mode Commands
Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine
1.
Preparing to Replace a Solid-State Disk from a T4000 RE-C1800 Routing
Engine on page 273
2.
Removing a Solid-State Disk from a T4000 RE-C1800 Routing Engine on page 274
3.
Installing a Solid-State Disk From a T4000 RE-C1800 Routing Engine on page 275
4.
Copying Junos OS to the Solid-State Disk in a T4000 RE-C1800 Routing
Engine on page 275
Preparing to Replace a Solid-State Disk from a T4000 RE-C1800 Routing Engine
To prepare to replace an SSD:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of these methods:
• Check the Host Subsystem LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Check the MASTER LED on the control board. If the blue MASTER LED is lit, the host subsystem is functioning as the master.
• Issue the show chassis routing-engine . command.
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
2.
If the host subsystem is functioning as the master, switch it to backup. Issue the request chassis routing-engine master switch command.
3.
From the master Routing Engine, power down the backup Routing Engine. Issue the request system power-off other-routing-engine command.
Copyright © 2013, Juniper Networks, Inc.
273
T4000 Router Hardware Guide
Removing a Solid-State Disk from a T4000 RE-C1800 Routing Engine
The solid-state disk (SSD) is located in the slot labeled DISK1 on the Routing Engine faceplate.
NOTE: The DISK2 slot is not currently supported.
To remove an SSD from a Routing Engine (see Figure 130 on page 274 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Verify that the Online , DISK1 , and CF LEDs on the backup Routing Engine faceplate are off.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the corners of the cover.
5.
Remove the cover from the Routing Engine slots.
CAUTION: Do not remove the cover if any of the LEDs on the Routing
Engine faceplate are lit.
6.
Press the eject button on the right side of the DISK1 slot to release the SSD.
7.
The SSD pops partially out of the slot. Grasp the SSD and carefully slide it completely out of the slot.
8.
Place the SSD on the antistatic mat.
Figure 130: Removing an SSD
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF CF
S
K
1
D
I
K
2
D
I
S
USB
Offline
Online
274 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Installing a Solid-State Disk From a T4000 RE-C1800 Routing Engine
To install an SSD in a Routing Engine (see Figure 131 on page 275 ):
1.
Insert the SSD into the DISK1 slot on the Routing Engine, with the logo facing down.
CAUTION: Be sure to insert the SSD with the label facing down. Inserting the SSD incorrectly might damage the Routing Engine.
2.
Slide the SSD into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
3.
Reinstall the Routing Engine cover. Using a Phillips (+) screwdriver, number 2, tighten the screws on the corners of the cover to secure it to the Routing Engine .
4.
From the master Routing Engine, power on the Routing Engine. Issue the request system power-on other-routing-engine command.
Figure 131: Installing an SSD
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
CF
K
1
D
I
S
S
K
2
D
I
USB
Offline
Online
Copying Junos OS to the Solid-State Disk in a T4000 RE-C1800 Routing Engine
After installing a solid-state disk (SSD) for the first time, you must copy the software from the Routing Engine's CompactFlash card to the SSD.
To copy software to the SSD:
1.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode.
2.
Partition the SSD. Issue the request system partition hard-disk command.
3.
Wait until a message appears on the console confirming that the partition procedure is complete.
4.
Reboot the router's software. Issue the request system reboot command.
5.
Back up the currently running and active file system partitions on the router to standby partitions that are not running. Issue the request system snapshot command.
6.
Wait until a message appears on the console confirming that the snapshot procedure is complete.
Copyright © 2013, Juniper Networks, Inc.
275
T4000 Router Hardware Guide
7.
Reboot the router's software again. Issue the request system reboot command.
8.
Verify that the SSD is listed as the secondary boot device. The output lists the devices mounted. The SSD is located at ad1 . Issue the show system boot-messages command.
Related
Documentation
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
• T4000 Craft Interface LEDs on page 25
• Preventing T4000 Electrostatic Discharge Damage on page 296
• Chassis Operational Mode Commands
• System Software Operational Mode Commands
Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine
1.
Removing a DIMM Module from a T4000 RE-C1800 Routing Engine on page 276
2.
Installing a DIMM Module into a T4000 RE-C1800 Routing Engine on page 276
Removing a DIMM Module from a T4000 RE-C1800 Routing Engine
To remove a DIMM module:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Remove the Routing Engine. See “Replacing a T4000 Routing Engine” on page 267 .
4.
Eject the DIMM module by pressing the plastic ejectors on both sides of the DIMM module.
5.
Grasp the DIMM module, being careful not to touch any electrical components on the module, and firmly pull it out of the slot on the Routing Engine.
6.
Place the DIMM module on the antistatic mat or in the electrostatic bag.
7.
Push the plastic ejectors to close the empty DIMM module slot.
Installing a DIMM Module into a T4000 RE-C1800 Routing Engine
To insert a DIMM module into the Routing Engine:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the DIMM module from its electrostatic bag.
3.
To open the empty DIMM slot, press the plastic ejectors open.
276 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
4.
Grasp the DIMM module by the edges, being careful not to touch any electrical components.
5.
Press firmly on both ends, and push the module into the slot until the ejectors return completely to the closed position.
6.
Install the Routing Engine. See “Replacing a T4000 Routing Engine” on page 267 .
7.
You can view the SDRAM configuration and verify that the DIMM was installed correctly by issuing the show chassis routing-engine command.
Related
Documentation
• T4000 Routing Engine Description on page 39
• T4000 RE-C1800 Routing Engine Description on page 40
• T4000 RE-C1800 LEDs on page 41
• T4000 Craft Interface LEDs on page 25
• Preventing T4000 Electrostatic Discharge Damage on page 296
Replacing a T4000 SCG
1.
Removing a T4000 SCG on page 277
2.
Installing a T4000 SCG on page 278
Removing a T4000 SCG
The router can have one or two SCGs installed. The SCGs are located in the upper rear of the chassis, above the control boards and Routing Engines. Each SCG weighs approximately 1.9 lb (0.9 kg).
A nonredundant SCG is hot-pluggable. For redundant SCGs, the master SCG is hot-pluggable. The backup SCG is hot-removable and hot-insertable if the master SCG is functioning. Removing the backup SCG does not affect the functioning of the router.
Taking the master SCG offline might result in a brief loss of SONET clock lock while the backup SCG becomes the master.
To remove an SCG (see Figure 132 on page 278 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Press the online/offline button on the SCG faceplate, and hold it down until the LED goes out (about 5 seconds).
4.
Loosen the captive screws on the edges of the SCG faceplate.
5.
Grasp the SCG by the handle on the faceplate, and slide it out of the chassis.
6.
Place the SCG on the antistatic mat.
Copyright © 2013, Juniper Networks, Inc.
277
T4000 Router Hardware Guide
Figure 132: Removing an SCG
Installing a T4000 SCG
To install a replacement SCG (see Figure 133 on page 279 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Carefully align the sides of the SCG with the guides in the SCG slot.
3.
Grasp the SCG by its handle, and slide it straight into the chassis until it contacts the midplane.
4.
Tighten the captive screws on the corners of the SCG faceplate.
5.
To bring the SCG online, press the online/offline button until the green OK LED lights.
6.
To verify that the SCG is installed correctly and is functioning normally, check the
LEDs on the SCG faceplate. The green OK LED should light steadily. If the SCG is master, the blue MASTER LED should also light steadily.
To check the status of the SCGs, use the following CLI command: user@host> show chassis environment scg
SCG 0 status:
State Online - Master clock
Temperature 38 degrees C / 100 degrees F
Power
GROUND 0 mV
1.8 V bias 1797 mV
3.3 V 3312 mV
3.3 V bias 3274 mV
5.0 V 5047 mV
5.0 V bias 4989 mV
5.6 V 5758 mV
8.0 V bias 7560 mV
Bus Revision 40
SCG 1 status:
State Online - Standby
Temperature 38 degrees C / 100 degrees F
Power
GROUND 0 mV
1.8 V bias 1786 mV
3.3 V 3318 mV
3.3 V bias 3286 mV
278 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
5.0 V 5037 mV
5.0 V bias 5001 mV
5.6 V 5777 mV
8.0 V bias 7582 mV
Bus Revision 40
Figure 133: Installing an SCG
Related
Documentation
• T4000 SONET Clock Generators (SCGs) Description on page 49
• T4000 SONET Clock Generators (SCGs) LEDs on page 51
• Maintaining the T4000 SCGs on page 187
• Troubleshooting the T4000 SCGs on page 208
• Preventing T4000 Electrostatic Discharge Damage on page 296
• Chassis Operational Mode Commands
Replacing a T4000-SIB
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each T4000 SIB weighs approximately 6.5 lb (3.0 kg).
1.
Removing a T4000-SIB on page 279
2.
Installing a T4000-SIB on page 280
Removing a T4000-SIB
To remove a SIB (see Figure 134 on page 280 ):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
Copyright © 2013, Juniper Networks, Inc.
279
T4000 Router Hardware Guide
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 134: Removing a T4000 SIB
Installing a T4000-SIB
To install a T4000-SIB (see Figure 135 on page 282 ):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles, and press them inward to seat the SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots. You might have to close and open the handles a few times before the tabs catch the slots.
280 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
6.
Tighten the captive screws on the ejector handles.
7.
Bring the SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the SIB faceplate. The green OK
LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router:
8.
user@host> request chassis sib online slot 0
Check the LEDs on the SIB faceplate.
• The green OK LED should light steadily a few minutes after the SIB is installed.
• If the FAIL LED is lit steadily, remove and install the SIB again. Make sure that the
SIB is seated properly. If the FAIL LED still lights steadily, the SIB is not functioning properly. Contact your customer support representative.
9.
Verify that four SIBs are in the Online state and one SIB is in the Spare state. Display the status of the SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 13 hours, 16 minutes, 49 seconds
2 Online 1 day, 13 hours, 16 minutes, 33 seconds
3 Online 1 day, 13 hours, 16 minutes, 16 seconds
4 Online 1 day, 13 hours, 16 minutes
Copyright © 2013, Juniper Networks, Inc.
281
T4000 Router Hardware Guide
Figure 135: Installing a T4000 SIB
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000-SIB Description on page 46
• Maintaining the T4000 SIBs on page 186
• Troubleshooting the T4000 SIBs on page 209
• Preventing T4000 Electrostatic Discharge Damage on page 296
Replacing a T4000 TXP-LCC-3D SIB
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 .
Each TXP-LCC-3D SIB weighs approximately 9.4 lb (4.2 kg). The TXP-LCC-3D SIBs are connected to the TXP-F13-3D SIBs in a TX Matrix Plus router.
TXP-LCC-3D SIBs in active data switching planes are hot-pluggable. TXP-LCC-3D SIBs in a spare data switching planes are hot-insertable and hot-removable. When you remove a TXP-LCC-3D SIB in a spare switching plane, traffic forwarding continues without any degradation as long as the other four switching planes remain online. However, removing a TXP-LCC-3D SIB in an active switching plane might cause performance degradation in that switching plane. To avoid performance degradation, you can take the switching
282 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components plane offline before you remove a TXP-LCC-3D SIB. For more information, see the TX
Matrix Plus Router Hardware Guide
1.
Removing a T4000 TXP-LCC-3D SIB on page 283
2.
Installing a T4000 TXP-LCC-3D SIB on page 285
Removing a T4000 TXP-LCC-3D SIB
To remove a TXP-LCC-3D SIB:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Ensure that the cables connected to the TXP-LCC-3D SIB are labeled so you can reconnect them correctly.
4.
Use one of the following methods to take the TXP-LCC-3D SIB offline:
• Issue the request chassis sib lcc number slot slot-number offline command. For example: user@host> request chassis sib lcc 0 slot 3 offline
Online initiated, use "show chassis sibs" to verify
• Press and hold the SIB ONLINE/OFFLINE button in the middle of the TXP-LCC-3D
SIB faceplate to take the SIB offline. Hold the buttons down until all the LEDs on the faceplate are not lit.
5.
Remove each switching plane cable from the SIB.
• CXP—Disconnect the CXP cables ( Figure 136 on page 284 ) from the CXP transceivers.
After all the CXP cables have been disconnected from the transceivers, remove the
CXP transceivers ( Figure 137 on page 284 ) from the SIB.
WARNING: Do not look directly into a CXP cable connected to a port.
The fiber optics emit laser light that can damage your eyes.
• AOC—Remove the AOC transceivers from the SIB ( Figure 138 on page 284 ).
6.
Install dust covers on the cables and transceivers that you removed. Align the dust cover with the cable or transceiver and carefully press them together until they stop.
The dust cover and the cable or transceiver are keyed to ensure proper mating.
• CXP—Install a dust cover on each CXP transceiver and CXP cable.
• AOC—Install a dust cover on each AOC transceiver.
7.
Move the cables to the side of the SIB so they do not interfere with the removal of the
SIB.
8.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the ejector handles on each side of the SIB faceplate.
9.
Flip the ejector handles outward to unseat the SIB ( Figure 139 on page 285 ).
Copyright © 2013, Juniper Networks, Inc.
283
T4000 Router Hardware Guide
10.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
11.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 136: CXP Cable and Dust Cover
CXP switching plane cable CXP switching plane cable with dust cover
Figure 137: CXP Transceiver and Dust Cover
CXP transceiver
CXP transceiver with dust cover
Figure 138: AOC Transceiver and Dust Cover
AOC switching plane cable and transceiver
AOC switching plane cable and transceiver with dust cover
284 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Figure 139: Removing a TXP-LCC-3D SIB
Installing a T4000 TXP-LCC-3D SIB
To install a TXP-LCC-3D SIB:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned
( Figure 140 on page 287 ).
5.
Grasp both ejector handles, and press them inward to seat the SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots. You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Remove the dust covers from the transceivers and cables. Store the dust covers in a dust-free resealable plastic bag.
8.
Insert the transceiver into the ports.
• CXP—Insert the CXP transceivers into the TXP-LCC-3D ports. The CXP transceivers and the port are keyed to ensure proper mating. After all the CXP transceiver have been installed, reconnect each CXP cable ( Figure 141 on page 287 ) to the CXP transceiver in the TXP-LCC-3D port that corresponds to the label on the cable.
Copyright © 2013, Juniper Networks, Inc.
285
T4000 Router Hardware Guide
Align the cable with the port and carefully press it into the port until it your hear a click and it stops. The CXP cables and CXP transceivers are keyed to ensure proper mating.
• AOC—Using the cable labels, insert each AOC transceiver into its corresponding
TXP-F13-3D port ( Figure 142 on page 288 ).
Align the transceiver with the port and carefully press it into the port until it your hear a click and it stops. The AOC transceivers and the port are keyed to ensure proper mating.
9.
Bring the TXP-LCC-3D SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the TXP-LCC-3D SIB faceplate. The green OK LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
10.
Check the LEDs on the TXP-LCC-3D SIB faceplate.
• The green OK LED should light steadily a few minutes after the SIB is installed.
• If the FAIL LED is lit steadily, remove and install the TXP-LCC-3D SIB again. Make sure that the SIB is seated properly. If the FAIL LED still lights steadily, the SIB is not functioning properly. Contact your customer support representative.
11.
Verify that four SIBs are in the Online state and one SIB is in the Spare state. Display the status of the SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 13 hours, 16 minutes, 49 seconds
2 Online 1 day, 13 hours, 16 minutes, 33 seconds
3 Online 1 day, 13 hours, 16 minutes, 16 seconds
4 Online 1 day, 13 hours, 16 minutes
If a SIB is not online, issue the request chassis sib online operational mode command.
286 Copyright © 2013, Juniper Networks, Inc.
Chapter 19: Replacing T4000 Router Hardware Components
Figure 140: Installing a TXP-LCC-3D SIB
Figure 141: Connecting a CXP Cable to a CXP Transceiver
TXP-LCC-3D
SIB
CXP transceiver
CXP cable
Copyright © 2013, Juniper Networks, Inc.
287
T4000 Router Hardware Guide
Figure 142: Installing an AOC Transceiver
AOC transceiver
TXP-LCC-3D
SIB
Related
Documentation
• T4000 Switch Interface Board (SIB) Description on page 46
• T4000 TXP-LCC-3D SIB Description on page 47
• Maintaining the T4000 SIBs on page 186
• Troubleshooting the T4000 SIBs on page 209
• Preventing T4000 Electrostatic Discharge Damage on page 296
288 Copyright © 2013, Juniper Networks, Inc.
PART 5
Appendixes
• Router Safety and Regulatory Compliance Information on page 291
• T4000 Router Physical Specifications on page 331
• T4000 Router Environmental Specifications on page 333
• Power Guidelines, Requirements, and Specifications on page 335
• T4000 Router Cable and Wire Specifications, Pinouts, and Guidelines on page 345
• Contacting Customer Support and Returning Router Hardware on page 353
Copyright © 2013, Juniper Networks, Inc.
289
T4000 Router Hardware Guide
290 Copyright © 2013, Juniper Networks, Inc.
APPENDIX A
Router Safety and Regulatory Compliance
Information
• Definition of Safety Warning Levels on page 291
• General Safety Guidelines and Warnings on page 293
• Fire Safety Requirements for Juniper Networks Devices on page 299
• T4000 Installation Safety Guidelines on page 300
• Installation Safety Warnings for Juniper Networks Devices on page 301
• Laser and LED Safety Guidelines and Warnings on page 305
• T4000 Maintenance and Operational Safety Guidelines and Warnings on page 309
• T4000 Electrical Safety Guidelines and Warnings on page 314
• Agency Approvals and Compliance Statements on page 324
Definition of Safety Warning Levels
The documentation uses the following levels of safety warnings:
NOTE: You might find this information helpful in a particular situation, or might otherwise overlook it.
CAUTION: You must observe the specified guidelines to avoid minor injury or discomfort to you, or severe damage to the hardware device.
WARNING: This symbol alerts you to the risk of personal injury from a laser.
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Copyright © 2013, Juniper Networks, Inc.
291
T4000 Router Hardware Guide
292
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer
Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der
Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
¡Atención!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Related
Documentation
• General Safety Warnings for Juniper Networks Devices on page 294
• Installation Safety Warnings for Juniper Networks Devices on page 301
• Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 309
• General Electrical Safety Warnings for Juniper Networks Devices on page 315
• DC Power Electrical Safety Warnings for Juniper Networks Devices on page 321
General Safety Guidelines and Warnings
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
• Preventing T4000 Electrostatic Discharge Damage on page 296
General Safety Guidelines for Juniper Networks Devices
The following guidelines help ensure your safety and protect the hardware equipment from damage. The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
• Perform only the procedures explicitly described in this documentation. Make sure that only authorized service personnel perform other system services.
• Keep the area around the chassis clear and free from dust before, during, and after installation.
• Keep tools away from areas where people could trip over them while walking.
• Do not wear loose clothing or jewelry, such as rings, bracelets, or chains, which could become caught in the chassis.
• Wear safety glasses if you are working under any conditions that could be hazardous to your eyes.
• Do not perform any actions that create a potential hazard to people or make the equipment unsafe.
• Never attempt to lift an object that is too heavy for one person to handle.
• Never install or manipulate wiring during electrical storms.
• Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments.
• Operate the hardware equipment only when the chassis is properly grounded.
• Do not open or remove chassis covers or sheet metal parts unless instructions are provided in this documentation. Such an action could cause severe electrical shock.
• Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire.
Copyright © 2013, Juniper Networks, Inc.
293
T4000 Router Hardware Guide
• Avoid spilling liquid onto the chassis or onto any hardware component. Such an action could cause electrical shock or damage the hardware equipment.
• Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Such an action could cause electrical shock.
Related
Documentation
• General Safety Warnings for Juniper Networks Devices on page 294
General Safety Warnings for Juniper Networks Devices
• Qualified Personnel Warning on page 294
• Restricted Access Area Warning on page 294
Qualified Personnel Warning
WARNING: Only trained and qualified personnel should install or replace the hardware equipment.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent.
Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Aviso Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado.
¡Atención!
Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado.
Varning!
Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Restricted Access Area Warning
WARNING: The hardware equipment is intended for installation in restricted access areas. A restricted access area is an area to which access can be
294 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Copyright © 2013, Juniper Networks, Inc.
gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location.
Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang. Een plaats met beperkte toegang is een plaats waar toegang slechts door servicepersoneel verkregen kan worden door middel van een speciaal instrument, een slot en sleutel, of een ander veiligheidsmiddel, en welke beheerd wordt door de overheidsinstantie die verantwoordelijk is voor de locatie.
Varoitus Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Paikka, johon pääsy on rajoitettua, tarkoittaa paikkaa, johon vain huoltohenkilöstö pääsee jonkin erikoistyökalun, lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkilöiden valvoma.
Attention Cet appareil est à installer dans des zones d'accès réservé. Ces dernières sont des zones auxquelles seul le personnel de service peut accéder en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de sécurité. L'accès aux zones de sécurité est sous le contrôle de l'autorité responsable de l'emplacement.
Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem
Zutritt vorgesehen. Ein Bereich mit beschränktem Zutritt ist ein Bereich, zu dem nur Wartungspersonal mit einem Spezialwerkzeugs, Schloß und
Schlüssel oder anderer Sicherheitsvorkehrungen Zugang hat, und der von dem für die Anlage zuständigen Gremium kontrolliert wird.
Avvertenza Questa unità deve essere installata in un'area ad accesso limitato.
Un'area ad accesso limitato è un'area accessibile solo a personale di assistenza tramite un'attrezzo speciale, lucchetto, o altri dispositivi di sicurezza, ed è controllata dall'autorità responsabile della zona.
Advarsel Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.
Aviso Esta unidade foi concebida para instalação em áreas de acesso restrito.
Uma área de acesso restrito é uma área à qual apenas tem acesso o pessoal de serviço autorizado, que possua uma ferramenta, chave e fechadura especial, ou qualquer outra forma de segurança. Esta área é controlada pela autoridade responsável pelo local.
¡Atención!
Esta unidad ha sido diseñada para instalarse en áreas de acceso restringido. Área de acceso restringido significa un área a la que solamente tiene acceso el personal de servicio mediante la utilización de una herramienta
295
T4000 Router Hardware Guide especial, cerradura con llave, o algún otro medio de seguridad, y que está bajo el control de la autoridad responsable del local.
Varning!
Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat tillträde får endast tillträdas av servicepersonal med ett speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras av den auktoritet som ansvarar för området.
Related
Documentation
• Installation Safety Warnings for Juniper Networks Devices on page 301
• Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 309
• General Electrical Safety Warnings for Juniper Networks Devices on page 315
• DC Power Electrical Safety Warnings for Juniper Networks Devices on page 321
Preventing T4000 Electrostatic Discharge Damage
Many router hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
• Always use an ESD wrist strap or ankle strap, and make sure that it is in direct contact with your skin.
CAUTION: For safety, periodically check the resistance value of the ESD strap. The measurement should be in the range of 1 to 10 Mohms.
• When handling any component that has been removed from the chassis, verify that the equipment end of your ESD strap is attached to one of the ESD points on the chassis, which are shown in Figure 143 on page 297 and Figure 144 on page 298 .
• Avoid contact between the component and your clothing. ESD voltages emitted from clothing can still damage components.
• When removing or installing a component, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an electrostatic bag (see
Figure 145 on page 298 ). If you are returning a component, place it in an electrostatic bag before packing it.
296 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Figure 143: ESD Point on Front of the Router
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
T Series
FANTRAY-T4000
ESD point
Air filter
Fan tray
Air intake
FANTRA
Y-T4000
Copyright © 2013, Juniper Networks, Inc.
297
T4000 Router Hardware Guide
Figure 144: ESD Point on Rear of the Router
Fan tray
Air exhaust
SCGs
Control board 0
RE 0
RE 1
Control board 1
SIBs
Air filter
Power supply 0
Power supply 1
ESD point
Grounding points
Figure 145: Placing a Component into an Electrostatic Bag
298 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Related
Documentation
• T4000 Chassis Description on page 15
• Overview of Grounding the T4000 Router on page 109
• T4000 Chassis Grounding Cable and Lug Specifications on page 335
Fire Safety Requirements for Juniper Networks Devices
• General Fire Safety Requirements on page 299
• Fire Suppression on page 299
• Fire Suppression Equipment on page 299
General Fire Safety Requirements
In the event of a fire emergency involving network devices, the safety of people is the primary concern. Establish procedures for protecting people in a fire emergency, provide safety training, and properly provision fire-control equipment and fire extinguishers.
In addition, establish procedures to protect your equipment in a fire emergency. Juniper
Networks products should be installed in an environment suitable for electronic equipment. We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment, and that you observe all local fire, safety, and electrical codes and ordinances when installing and operating your equipment.
Fire Suppression
In the event of an electrical hazard or an electrical fire, first turn power off to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire.
Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide
(CO
2
) and Halotron, are most effective for suppressing electrical fires. Type C fire extinguishers displace the oxygen from the point of combustion to eliminate the fire. For extinguishing fire on or around equipment that draws air from the environment for cooling, use this type of inert oxygen displacement extinguisher instead of an extinguisher that leave residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire extinguishers) near Juniper Networks devices. The primary ingredient in these fire extinguishers is monoammonium phosphate, which is very sticky and difficult to clean.
In addition, in minute amounts of moisture, monoammonium phosphate can become highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation. The equipment is considered to be irreparably damaged.
Copyright © 2013, Juniper Networks, Inc.
299
T4000 Router Hardware Guide
NOTE: To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner.
Related
Documentation
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
• General Electrical Safety Warnings for Juniper Networks Devices on page 315
• DC Power Electrical Safety Warnings for Juniper Networks Devices on page 321
T4000 Installation Safety Guidelines
Observe the following guidelines before and during router installation:
• General Installation Safety Guidelines on page 300
• Chassis Lifting Guidelines on page 300
General Installation Safety Guidelines
Before installing or moving the router, verify that the intended site meets the specified power, environmental, and clearance requirements. See the following documentation:
• T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 59
• Rack Requirements for the T4000 Router on page 58
• T4000 Router Environmental Specifications on page 333
• T4000 DC Power Requirements on page 338
Chassis Lifting Guidelines
The weight of a fully configured router is about 663.6 lb (301.0 kg). Observe the following guidelines for lifting and moving the router:
• Do not attempt to lift a fully configured router by yourself. Using a mechanical lift to maneuver the router into a rack is recommended. If a lift cannot be used, a minimum of 4 people are required to lift the router, and you must remove components from the chassis before lifting.
• Before lifting or moving the router, disconnect all external cables.
• As when lifting any heavy object, lift most of the weight with your legs rather than your back. Keep your knees bent and your back relatively straight and avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
300 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Related
Documentation
• Overview of Preparing the Site for the T4000 Router on page 57
Installation Safety Warnings for Juniper Networks Devices
Observe the following warnings before and during hardware equipment installation:
• Installation Instructions Warning on page 301
• Rack-Mounting Requirements and Warnings on page 301
• Ramp Warning on page 305
Installation Instructions Warning
WARNING: Read the installation instructions before you connect the hardware equipment to a power source.
Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt.
Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen.
Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Aviso Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia.
¡Atención!
Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Varning!
Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.
Rack-Mounting Requirements and Warnings
Ensure that the equipment rack into which the chassis is installed is evenly and securely supported, to avoid the hazardous condition that could result from uneven mechanical loading.
Copyright © 2013, Juniper Networks, Inc.
301
T4000 Router Hardware Guide
302
WARNING: To prevent bodily injury when mounting or servicing the chassis in a rack, take the following precautions to ensure that the system remains stable. The following directives help maintain your safety:
• The chassis must be installed into a rack that is secured to the building structure.
• The chassis should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting the chassis in a partially filled rack, load the rack from the bottom to the top, with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting the chassis in the rack or servicing the hardware equipment.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren:
• De router moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd.
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
• Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de stabilisatoren te monteren voordat u het toestel in het rek monteert of het daar een servicebeurt geeft.
Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
• Router on asennettava telineeseen, joka on kiinnitetty rakennukseen.
• Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
• Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
• Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista telineeseen tai sen huoltamista siinä.
Attention Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel:
Copyright © 2013, Juniper Networks, Inc.
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
• Le rack sur lequel est monté le router doit être fixé à la structure du bâtiment.
• Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier.
Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:
• Der router muß in einem Gestell installiert werden, das in der
Gebäudestruktur verankert ist.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.
Avvertenza Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale:
• Il router deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio.
• Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità da montare nel supporto.
• Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto.
• Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten:
303
T4000 Router Hardware Guide
304
• Router må installeres i et stativ som er forankret til bygningsstrukturen.
• Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene installeres før montering eller utføring av reparasjonsarbeid på enheten i kabinettet.
Aviso Para se prevenir contra danos corporais ao montar ou reparar esta unidade numa estante, deverá tomar precauções especiais para se certificar de que o sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a efectuar o seu trabalho com segurança:
• O router deverá ser instalado numa prateleira fixa à estrutura do edificio.
• Esta unidade deverá ser montada na parte inferior da estante, caso seja esta a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os itens mais pesados na parte inferior da estante, arrumando-os de baixo para cima.
• Se a estante possuir um dispositivo de estabilização, instale-o antes de montar ou reparar a unidade.
¡Atención!
Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones:
• El router debe instalarse en un bastidor fijado a la estructura del edificio.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
• Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior.
• Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Varning!
För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet:
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
• Router måste installeras i en ställning som är förankrad i byggnadens struktur.
• Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
• Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
• Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast innan enheten installeras eller underhålls på ställningen.
Ramp Warning
WARNING: When installing the hardware equipment, do not use a ramp inclined at more than 10 degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención!
No usar una rampa inclinada más de 10 grados
Varning!
Använd inte ramp med en lutning på mer än 10 grader.
Related
Documentation
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
• Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 309
Laser and LED Safety Guidelines and Warnings
• T4000 General Laser Safety Guidelines on page 306
• Laser Safety Warnings for Juniper Networks Devices on page 306
Copyright © 2013, Juniper Networks, Inc.
305
T4000 Router Hardware Guide
T4000 General Laser Safety Guidelines
Devices with single-mode optical interfaces are equipped with laser transmitters, which are considered a Class 1 Laser Product by the U.S. Food and Drug Administration, and are evaluated as a Class 1 Laser Product according to EN 60825–1 +A11 +A2 requirements.
When working around devices with optical interfaces, observe the following safety guidelines to prevent eye injury:
• Do not look into unterminated ports or at fibers that connect to unknown sources.
• Do not examine unterminated optical ports with optical instruments.
• Avoid direct exposure to the beam.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye.
Related
Documentation
• Connecting PIC Cables to the T4000 Router on page 116
• Replacing a T4000 PIC on page 253
Laser Safety Warnings for Juniper Networks Devices
• Class 1 Laser Product Warning on page 306
• Class 1 LED Product Warning on page 307
• Laser Beam Warning on page 307
• Radiation from Open Port Apertures Warning on page 308
Class 1 Laser Product Warning
WARNING: Class 1 laser product.
Waarschuwing Klasse-1 laser produkt.
Varoitus Luokan 1 lasertuote.
Attention Produit laser de classe I.
Warnung Laserprodukt der Klasse 1.
Avvertenza Prodotto laser di Classe 1.
Advarsel Laserprodukt av klasse 1.
Aviso Produto laser de classe 1.
306 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
¡Atención!
Producto láser Clase I.
Varning!
Laserprodukt av klass 1.
Class 1 LED Product Warning
WARNING: Class 1 LED product.
Waarschuwing Klasse 1 LED-product.
Varoitus Luokan 1 valodiodituote.
Attention Alarme de produit LED Class I.
Warnung Class 1 LED-Produktwarnung.
Avvertenza Avvertenza prodotto LED di Classe 1.
Advarsel LED-produkt i klasse 1.
Aviso Produto de classe 1 com LED.
¡Atención!
Aviso sobre producto LED de Clase 1.
Varning!
Lysdiodprodukt av klass 1.
Laser Beam Warning
WARNING: Do not stare into the laser beam or view it directly with optical instruments.
Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten.
Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen
Geräten prüfen.
Avvertenza Non fissare il raggio con gli occhi né usare strumenti ottici per osservarlo direttamente.
Advarsel Stirr eller se ikke direkte p strlen med optiske instrumenter.
Aviso Não olhe fixamente para o raio, nem olhe para ele directamente com instrumentos ópticos.
Copyright © 2013, Juniper Networks, Inc.
307
T4000 Router Hardware Guide
308
¡Atención!
No mirar fijamente el haz ni observarlo directamente con instrumentos ópticos.
Varning!
Rikta inte blicken in mot strålen och titta inte direkt på den genom optiska instrument.
Radiation from Open Port Apertures Warning
WARNING: Because invisible radiation may be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverture du port lorsqu'aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Warnung Aus der Port-Öffnung können unsichtbare Strahlen emittieren, wenn kein Glasfaserkabel angeschlossen ist. Vermeiden Sie es, sich den
Strahlungen auszusetzen, und starren Sie nicht in die Öffnungen!
Avvertenza Quando i cavi in fibra non sono inseriti, radiazioni invisibili possono essere emesse attraverso l'apertura della porta. Evitate di esporvi alle radiazioni e non guardate direttamente nelle aperture.
Advarsel Unngå utsettelse for stråling, og stirr ikke inn i åpninger som er åpne, fordi usynlig stråling kan emiteres fra portens åpning når det ikke er tilkoblet en fiberkabel.
Aviso Dada a possibilidade de emissão de radiação invisível através do orifício da via de acesso, quando esta não tiver nenhum cabo de fibra conectado, deverá evitar a exposição à radiação e não deverá olhar fixamente para orifícios que se encontrarem a descoberto.
¡Atención!
Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación.
Varning!
Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Related
Documentation
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
• Installation Safety Warnings for Juniper Networks Devices on page 301
T4000 Maintenance and Operational Safety Guidelines and Warnings
• Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 309
Maintenance and Operational Safety Warnings for Juniper Networks Devices
As you maintain the hardware equipment, observe the following warnings:
• Battery Handling Warning on page 309
• Jewelry Removal Warning on page 310
• Lightning Activity Warning on page 311
• Operating Temperature Warning on page 312
• Product Disposal Warning on page 313
Battery Handling Warning
WARNING: Replacing the battery incorrectly might result in an explosion.
Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan.
Attention Danger d'explosion si la pile n'est pas remplacée correctement.
Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr.
Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den
Anweisungen des Herstellers.
Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni del produttore.
Copyright © 2013, Juniper Networks, Inc.
309
T4000 Router Hardware Guide
310
Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte.
Skift kun med samme eller tilsvarende type som er anbefalt av produsenten.
Kasser brukte batterier i henhold til produsentens instruksjoner.
Aviso Existe perigo de explosão se a bateria for substituída incorrectamente.
Substitua a bateria por uma bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas conforme as instruções do fabricante.
¡Atención!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Varning!
Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande.
Följ tillverkarens anvisningar vid kassering av använda batterier.
Jewelry Removal Warning
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen.
Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien).
Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin.
Attention Avant d'accéder à cet équipement connecté aux lignes électriques,
ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés
à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen.
Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden.
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais.
¡Atención!
Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes.
Varning!
Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.
Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.
Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Copyright © 2013, Juniper Networks, Inc.
311
T4000 Router Hardware Guide
312
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Aviso Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
¡Atención!
No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.
Varning!
Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Operating Temperature Warning
WARNING: To prevent the hardware equipment from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104
ο
F (40
ο
C). To prevent airflow restriction, allow at least
6 inches (15.2 cm) of clearance around the ventilation openings.
Waarschuwing Om te voorkomen dat welke router van de router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40
ο
C wordt overschreden. Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2 cm speling rond de ventilatie-openingen te zijn.
Varoitus Ettei router-sarjan reititin ylikuumentuisi, sitä ei saa käyttää tilassa, jonka lämpötila ylittää korkeimman suositellun ympäristölämpötilan 40
ο
C.
Ettei ilmanvaihto estyisi, tuuletusaukkojen ympärille on jätettävä ainakin 15,2 cm tilaa.
Attention Pour éviter toute surchauffe des routeurs de la gamme router, ne l'utilisez pas dans une zone où la température ambiante est supérieure à 40
ο
C. Pour permettre un flot d'air constant, dégagez un espace d'au moins 15,2 cm autour des ouvertures de ventilations.
Warnung Um einen router der router vor Überhitzung zu schützen, darf dieser nicht in einer Gegend betrieben werden, in der die Umgebungstemperatur das empfohlene Maximum von 40
ο
C überschreitet. Um Lüftungsverschluß zu verhindern, achten Sie darauf, daß mindestens 15,2 cm lichter Raum um die Lüftungsöffnungen herum frei bleibt.
Avvertenza Per evitare il surriscaldamento dei router, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40
ο
C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2
cm di fronte alle aperture delle ventole.
Advarsel Unngå overoppheting av eventuelle rutere i router Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information overstiger 40
ο
C (104
ο
F). Sørg for at klaringen rundt lufteåpningene er minst
15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Aviso Para evitar o sobreaquecimento do encaminhador router, não utilize este equipamento numa área que exceda a temperatura máxima recomendada de 40
ο
C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação.
¡Atención!
Para impedir que un encaminador de la serie router se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40
ο
C. Para impedir la restricción de la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las aperturas para ventilación.
Varning!
Förhindra att en router överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på
40
ο
C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Product Disposal Warning
WARNING: Disposal of this product must be handled according to all national laws and regulations.
Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.
Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.
Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.
Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia
Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.
¡Atención!
El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales
Copyright © 2013, Juniper Networks, Inc.
313
T4000 Router Hardware Guide
Varning!
Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.
Related
Documentation
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
T4000 Electrical Safety Guidelines and Warnings
• T4000 General Electrical Safety Guidelines on page 314
• General Electrical Safety Warnings for Juniper Networks Devices on page 315
• Site Electrical Wiring Guidelines for Juniper Networks Devices on page 318
• DC Power Electrical Safety Guidelines and Warnings on page 319
T4000 General Electrical Safety Guidelines
• Install the router in compliance with the following local, national, or international electrical codes:
• United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
• Canada—Canadian Electrical Code, Part 1, CSA C22.1.
• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
• Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
• Never assume that power is disconnected from a circuit. Always check the circuit before starting to work.
• Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension cords, and missing safety grounds.
• Operate the router within marked electrical ratings and product usage instructions.
• For the router and peripheral equipment to function safely and correctly, use the cables and connectors specified for the attached peripheral equipment, and make certain they are in good condition.
Many router components can be removed and replaced without powering off or disconnecting power to the router. Never install equipment if it appears damaged.
Related
Documentation
• General Safety Guidelines for Juniper Networks Devices on page 293
314 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
General Electrical Safety Warnings for Juniper Networks Devices
• Grounded Equipment Warning on page 315
• Grounding Requirements and Warning on page 315
• Midplane Energy Hazard Warning on page 316
• Multiple Power Supplies Disconnection Warning on page 316
• Power Disconnection Warning on page 317
Grounded Equipment Warning
WARNING: The network device is intended to be grounded. Ensure that the network device is connected to earth ground during normal use.
Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden.
Varoitus Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Attention Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Aviso Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal.
¡Atención!
Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal.
Varning!
Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
Grounding Requirements and Warning
An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors, but is identifiable by green and yellow stripes, is installed as part of the branch circuit that supplies the unit. The grounding conductor is a separately derived system at the supply transformer or motor generator set.
Copyright © 2013, Juniper Networks, Inc.
315
T4000 Router Hardware Guide
316
WARNING: When installing the network device, you must always make the ground connection first and disconnect it last.
Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.
Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Attention Lors de l'installation de l'appareil, la mise à la terre doit toujours
être connectée en premier et déconnectée en dernier.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist.
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.
¡Atención!
Al instalar el equipo, conectar la tierra la primera y desconectarla la última.
Varning!
Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
Midplane Energy Hazard Warning
WARNING: High levels of electrical energy are distributed across the midplane.
Be careful not to contact the midplane connectors, or any component connected to the midplane, with any metallic object while servicing components.
Multiple Power Supplies Disconnection Warning
WARNING: The network device has more than one power supply connection.
All connections must be removed completely to remove power from the unit completely.
Waarschuwing Deze eenheid heeft meer dan één stroomtoevoerverbinding; alle verbindingen moeten volledig worden verwijderd om de stroom van deze eenheid volledig te verwijderen.
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Varoitus Tässä laitteessa on useampia virtalähdekytkentöjä. Kaikki kytkennät on irrotettava kokonaan, jotta virta poistettaisiin täysin laitteesta.
Attention Cette unité est équipée de plusieurs raccordements d'alimentation.
Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Warnung Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit fernzuhalten, müssen alle Stromzufuhren abgetrennt sein.
Avvertenza Questa unità ha più di una connessione per alimentatore elettrico; tutte le connessioni devono essere completamente rimosse per togliere l'elettricità dall'unità.
Advarsel Denne enheten har mer enn én strømtilkobling. Alle tilkoblinger må kobles helt fra for å eliminere strøm fra enheten.
Aviso Este dispositivo possui mais do que uma conexão de fonte de alimentação de energia; para poder remover a fonte de alimentação de energia, deverão ser desconectadas todas as conexões existentes.
¡Atención!
Esta unidad tiene más de una conexión de suministros de alimentación; para eliminar la alimentación por completo, deben desconectarse completamente todas las conexiones.
Varning!
Denna enhet har mer än en strömförsörjningsanslutning; alla anslutningar måste vara helt avlägsnade innan strömtillförseln till enheten
är fullständigt bruten.
Power Disconnection Warning
WARNING: Before working on the chassis or near power supplies, switch off the power at the DC circuit breaker.
Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker van het netsnoer uit het stopcontact te halen; voor gelijkstroom toestellen dient u de stroom uit te schakelen bij de stroomverbreker.
Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimellä, ennen kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.
Attention Avant de travailler sur un châssis ou à proximité d'une alimentation
électrique, débrancher le cordon d'alimentation des unités en courant alternatif; couper l'alimentation des unités en courant continu au niveau du disjoncteur.
Copyright © 2013, Juniper Networks, Inc.
317
T4000 Router Hardware Guide
Warnung Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei Wechselstromeinheiten das Netzkabel ab bzw.
schalten Sie bei Gleichstromeinheiten den Strom am Unterbrecher ab.
Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle unità CA; scollegare l'alimentazione all'interruttore automatico sulle unità CC.
Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal strømledningen trekkes ut p vekselstrømsenheter og strømmen kobles fra ved strømbryteren på likestrømsenheter.
Aviso Antes de trabalhar num chassis, ou antes de trabalhar perto de unidades de fornecimento de energia, desligue o cabo de alimentação nas unidades de corrente alternada; desligue a corrente no disjuntor nas unidades de corrente contínua.
¡Atención!
Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación, desenchufar el cable de alimentación en los equipos de corriente alterna (CA); cortar la alimentación desde el interruptor automático en los equipos de corriente continua (CC).
Varning!
Innan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter dra ur nätsladden och för likströmsenheter bryta strömmen vid överspänningsskyddet.
Related
Documentation
• DC Power Electrical Safety Warnings for Juniper Networks Devices on page 321
Site Electrical Wiring Guidelines for Juniper Networks Devices
• Distance Limitations for Signaling on page 318
• Radio Frequency Interference on page 318
• Electromagnetic Compatibility on page 319
Distance Limitations for Signaling
Improperly installed wires can emit radio interference. In addition, the potential for damage from lightning strikes increases if wires exceed recommended distances or if wires pass between buildings. The electromagnetic pulse (EMP) caused by lightning can damage unshielded conductors and destroy electronic devices. If your site has previously experienced such problems, you might want to consult experts in electrical surge suppression and shielding.
Radio Frequency Interference
You can reduce or eliminate the emission of radio frequency interference (RFI) from your site wiring by using twisted-pair cable with a good distribution of grounding conductors.
318 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
If you must exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable.
Electromagnetic Compatibility
If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or radio transmitters, you might want to seek expert advice.
Strong sources of electromagnetic interference (EMI) can destroy the signal drivers and receivers in the network device and conduct power surges over the lines into the equipment, resulting in an electrical hazard. It is particularly important to provide a properly grounded and shielded environment and to use electrical surge-suppression devices.
CAUTION: To comply with intrabuilding lightning and surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends.
WARNING: The intrabuilding port(s) of the equipment or subassembly is suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring.
These interfaces are designed for use as intrabuilding interfaces only (Type
2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Related
Documentation
• General Electrical Safety Guidelines and Electrical Codes for Juniper Networks Devices
DC Power Electrical Safety Guidelines and Warnings
• T4000 DC Power Electrical Safety Guidelines on page 320
• DC Power Electrical Safety Warnings for Juniper Networks Devices on page 321
Copyright © 2013, Juniper Networks, Inc.
319
T4000 Router Hardware Guide
320
T4000 DC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to a DC-powered router:
• Incorporate an easily accessible disconnect device into the facility wiring. In the United
States and Canada, the –48 VDC facility should be equipped with a circuit breaker rated a minimum of 125% of the power provisioned for the input in accordance with the National Electrical Code in the US and the Canadian Electrical Code in Canada.
WARNING: Failure to provide the required circuit breaker or current-limiting fuse for each DC power cable can cause injury or damage to equipment.
Each 48 VDC facility DC source input power cable must be equipped with a current-limiting fuse or circuit breaker external to the Juniper Networks equipment rated at 100 A (–48 VDC) maximum for the six-input DC power supply, or as required by local code. The voltage rating of the facility DC source circuit breaker must be 80
V minimum. We recommend an 80 A circuit breaker or current-limiting fuse rated for each 60 A DC power cable. We recommend a 100 A circuit breaker or current-limiting fuse rated for each 80 A DC power cable
• The marked input voltage of –48 VDC for a DC-powered router is the nominal voltage associated with the battery circuit, and any higher voltages are only to be associated with float voltages for the charging function.
• A DC-powered router that is equipped with a DC terminal block is intended only for installation in a restricted access location. In the United States, a restricted access area is one in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical
Code ANSI/NFPA 70.
NOTE: Primary overcurrent protection is provided by the building circuit breaker. This breaker should protect against excess currents, short circuits, and earth faults in accordance with NEC ANSI/NFPA70.
• A DC-powered router is equipped with a DC terminal block that is rated for the power requirements of a maximally configured router. To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 60 A @ –48 VDC per input for the six-input DC power supply.
Run two wires from the circuit breaker box to a source of 48 VDC. Use appropriate gauge wire to handle up to 80 A for 60 A DC power cables or 100 A for 80 A DC power cables. .
NOTE: Only 60 A feeds are currently supported.
• Be sure to connect the ground wire or conduit to a solid office (earth) ground. A closed loop ring is recommended for terminating the ground conductor at the ground stud.
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
• Ensure that the polarity of the DC input wiring is correct. Under certain conditions, connections with reversed polarity might trip the primary circuit breaker or damage the equipment.
• For personal safety, connect the green and yellow wire to safety (earth) ground at both the router and the supply side of the DC wiring.
• Because the router is a positive ground system, you must connect the positive lead to the terminal labeled RTN , the negative lead to the terminal labeled –48V , and the earth ground to the chassis grounding points.
Related
Documentation
• Site Electrical Wiring Guidelines for Juniper Networks Devices on page 318
• T4000 General Electrical Safety Guidelines on page 314
• T4000 DC Power System Electrical Specifications on page 336
DC Power Electrical Safety Warnings for Juniper Networks Devices
When working with DC-powered equipment, observe the following warnings:
• DC Power Copper Conductors Warning on page 321
• DC Power Disconnection Warning on page 321
• DC Power Wiring Terminations Warning on page 323
DC Power Copper Conductors Warning
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
Attention Utilisez uniquement des conducteurs en cuivre.
Warnung Verwenden Sie ausschließlich Kupferleiter.
Avvertenza Usate unicamente dei conduttori di rame.
Advarsel Bruk bare kobberledninger.
Aviso Utilize apenas fios condutores de cobre.
¡Atención!
Emplee sólo conductores de cobre.
Varning!
Använd endast ledare av koppar.
DC Power Disconnection Warning
WARNING: Before performing any procedures on power supplies, ensure that power is removed from the DC circuit. To ensure that all power is off, locate
Copyright © 2013, Juniper Networks, Inc.
321
T4000 Router Hardware Guide
322 the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
Waarschuwing Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Attention Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.
Warnung Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den
Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den
Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Advarsel Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved
å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.
Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua.
Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF
(Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
¡Atención!
Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para
Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de
Apagado (OFF).
Varning!
Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
DC Power Wiring Terminations Warning
WARNING: When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations should be the appropriate size for the wires and should clamp both the insulation and conductor.
Waarschuwing Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten, zoals het gesloten-lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen.
Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelassene
Verdrahtungsabschlüsse, z.B. Ringoesen oder gabelförmige Kabelschuhe mit nach oben gerichteten Enden zu verwenden. Diese Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen.
Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l'alto. I connettori devono avere la misura adatta per il cablaggio e devono serrare sia l'isolante che il conduttore.
Advarsel Hvis det er nødvendig med flertrådede ledninger, brukes godkjente ledningsavslutninger, som for eksempel lukket sløyfe eller spadetype med
Copyright © 2013, Juniper Networks, Inc.
323
T4000 Router Hardware Guide oppoverbøyde kabelsko. Disse avslutningene skal ha riktig størrelse i forhold til ledningene, og skal klemme sammen både isolasjonen og lederen.
Aviso Quando forem requeridas montagens de instalação eléctrica de cabo torcido, use terminações de cabo aprovadas, tais como, terminações de cabo em circuito fechado e planas com terminais de orelha voltados para cima.
Estas terminações de cabo deverão ser do tamanho apropriado para os respectivos cabos, e deverão prender simultaneamente o isolamento e o fio condutor.
¡Atención!
Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, tales como las de tipo "bucle cerrado" o "espada", con las lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.
Varning!
När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda.
Related
Documentation
• General Safety Warnings for Juniper Networks Devices on page 294
• General Electrical Safety Warnings for Juniper Networks Devices on page 315
Agency Approvals and Compliance Statements
• T4000 Agency Approvals on page 324
• T4000 Compliance Statements for NEBS on page 326
• T4000 Compliance Statements for EMC Requirements (European
Community) on page 326
• Compliance Statements for EMC Requirements for Juniper Networks Devices
(Canada) on page 327
• Compliance Statements for EMC Requirements for Juniper Networks Devices
(Japan) on page 328
• Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States) on page 328
• Compliance Statements for Environmental Requirements for Juniper Networks
Devices on page 328
• T4000 Compliance Statements for Acoustic Noise on page 329
T4000 Agency Approvals
The router complies with the following standards:
• Safety
324 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
• CAN/CSA-22.2 No. 60950–1–07/UL 60950–1, 2nd Ed., Safety of Information
Technology Equipment
• EN 60825-1 +A1+A2 (1994) Safety of Laser Products - Part 1: Equipment Classification
• EMC
• AS/NZS 3548 Class A (Australia/New Zealand)
• EN55022 Class A (Europe)
• FCC Part 15 Class A (USA)
• VCCI Class A (Japan)
• Immunity
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic
Compatibility Requirements
The router is designed to comply with the following standards:
• NEBS
• GR-1089-Core: EMC and Electrical Safety for Network Telecommunications
Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
• GR-63-Core: NEBS, Physical Protection
Related
Documentation
• T4000 Router Description on page 3
• T4000 Compliance Statements for Acoustic Noise on page 329
• Compliance Statements for Environmental Requirements for Juniper Networks Devices on page 328
• Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada) on page 327
• T4000 Compliance Statements for EMC Requirements (European Community) on page 326
• Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 328
Copyright © 2013, Juniper Networks, Inc.
325
T4000 Router Hardware Guide
• Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States) on page 328
• T4000 Compliance Statements for NEBS on page 326
T4000 Compliance Statements for NEBS
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
• The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (i.e. DC-I), as defined in GR-1089-CORE.
Related
Documentation
• T4000 Agency Approvals on page 324
T4000 Compliance Statements for EMC Requirements (European Community)
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
326 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
Figure 146: Declaration of Conformity
Related
Documentation
• T4000 Agency Approvals on page 324
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada)
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Copyright © 2013, Juniper Networks, Inc.
327
T4000 Router Hardware Guide
Related
Documentation
• Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 328
• Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States) on page 328
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan)
Translation from Japanese—This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. VCCI-A
Related
Documentation
• Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada) on page 327
• Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States) on page 328
Compliance Statements for EMC Requirements for Juniper Networks Devices (United States)
The hardware equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Related
Documentation
• Site Electrical Wiring Guidelines for Juniper Networks Devices on page 318
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
Compliance Statements for Environmental Requirements for Juniper Networks Devices
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
Related
Documentation
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
328 Copyright © 2013, Juniper Networks, Inc.
Appendix A: Router Safety and Regulatory Compliance Information
T4000 Compliance Statements for Acoustic Noise
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 76.5 dB(A) oder weniger gemäss EN ISO 7779
Translation:
The emitted sound pressure resulted in 76.5 dB(A) per EN ISO 7779.
Related
Documentation
• T4000 Agency Approvals on page 324
Copyright © 2013, Juniper Networks, Inc.
329
T4000 Router Hardware Guide
330 Copyright © 2013, Juniper Networks, Inc.
APPENDIX B
T4000 Router Physical Specifications
• T4000 Router Physical Specifications on page 331
T4000 Router Physical Specifications
Table 43 on page 331 lists the router's physical specifications.
Table 43: Physical Specifications
Description Value
Chassis dimensions
Router weight
37.45 in. (95.1 cm) high
17.43 in. (44.3 cm) wide
31 in. (78.7 cm) deep
Total depth (including front cable management system)
35.5 in. (90.2 cm)
11.5 in. (29.2 cm) from front of chassis to center-mounting brackets
Chassis with midplane: 205 lb (93 kg)
Minimum configuration: 392 lb (177.8 kg)
Maximum configuration: 663.6 lb (301.0 kg)
Control board weight
Routing Engine weight
Craft interface weight
FPC weight
CIP weight
5 lb each (2 kg)
2.4 lb (1 kg)
3.3 lb (1.5 kg)
FPC4 with PICs installed: Up to 33 lb (15.0 kg)
FPC4 without PICs installed: up to 29 lb (11.3 kg)
FPC5 with PICs installed: Up to 33.5 lb (15.2 kg)
FPC5 without PICs installed: 31.6 lb (14.4 kg)
Blank panel in FPC slot: 9 lb (4.0 kg)
8.8 lb (4 kg)
Copyright © 2013, Juniper Networks, Inc.
331
T4000 Router Hardware Guide
Table 43: Physical Specifications
(continued)
Description Value
Air filter weight
Power supply weight
SCG weight
SIB weight
1 lb (0.45 kg)
39.7 lb (18.0 kg)
1.9 lb each (1 kg)
7.1 lb (3.2 kg)
SIB weight for SIB-TXP-3D-LCC
Front fan tray weight
Rear fan tray weight
Rear fan tray weight for
FAN-R-TXP-3D-LCC
9.4 lb (4.2 kg)
20.4 lb (9.3 kg)
10 lb (4.5 kg)
13 lb (5.9 kg)
Related
Documentation
• T4000 Router Description on page 3
• T4000 Chassis Description on page 15
• T4000 Installation Safety Guidelines on page 300
332 Copyright © 2013, Juniper Networks, Inc.
APPENDIX C
T4000 Router Environmental
Specifications
• T4000 Router Environmental Specifications on page 333
T4000 Router Environmental Specifications
Table 44 on page 333 specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.
Table 44: Router Environmental Specifications
Description Value
Altitude
Relative humidity
Temperature
Seismic
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping : –40°F (–40°C) to
158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake requirements
Maximum thermal output DC power: 33583.6 BTU/hour (9840 W W)
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
• Routine Maintenance Procedures for the T4000 Router on page 179
• General Safety Guidelines for Juniper Networks Devices on page 293
• General Safety Warnings for Juniper Networks Devices on page 294
Copyright © 2013, Juniper Networks, Inc.
333
T4000 Router Hardware Guide
334 Copyright © 2013, Juniper Networks, Inc.
APPENDIX D
Power Guidelines, Requirements, and
Specifications
• T4000 Chassis Grounding Cable and Lug Specifications on page 335
• T4000 DC Power System Electrical Specifications on page 336
• T4000 DC Power Supply Specifications on page 337
• T4000 DC Power Requirements on page 338
• T4000 Power Management (Four 60-A Cables on a Six-Input DC Power
Supply) on page 340
• T4000 Power Management (Three 80-A Cables on a Six-Input DC Power
Supply) on page 340
• T4000 DC Power Cable and Lugs Specifications on page 341
• T4000 DC Power Distribution on page 343
T4000 Chassis Grounding Cable and Lug Specifications
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the router must be adequately grounded before power is connected.
Two pairs of threaded inserts (PEM nuts) are provided on the right rear of the chassis for connecting the router to earth ground. The left pair of grounding points fits M6 screws
(European), and the right pair fits UNC 1/4–20 screws (American). The grounding points are spaced at 0.625-in. (15.86-mm) centers.
You must supply a grounding cable.
Table 45 on page 335 summarizes the specifications for the grounding cable and lug.
Table 45: Grounding Cable Specifications
Cable specification 8-AWG (8.35 mm
2
), minimum 90°C wire, or as required by the local code.
Connector specification Cable lug; at 0.625-in. (15.86-mm) center line.
Copyright © 2013, Juniper Networks, Inc.
335
T4000 Router Hardware Guide
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding cable that you supply. A cable with an incorrectly attached lug can damage the router.
The accessory box shipped with the router includes one 4-AWG (21.2 mm
2 cable lug that attaches to the grounding cable and is used to secure the grounding cable to the grounding points (see Figure 147 on page 336 ). (The cable lug shown in Figure 147 on page 336 is also used for the DC power cables.)
Figure 147: Grounding Cable Lug
Related
Documentation
• Tools and Parts Required to Ground the T4000 Router on page 109
• Connecting the T4000 Grounding Cable on page 110
T4000 DC Power System Electrical Specifications
Table 46 on page 336 lists the DC power system electrical specifications.
Table 46: DC Power System Electrical Specifications
Item Specification
DC input voltage
DC system current rating
Operating range: –40.0 to –72.0 VDC
205 A @ –48 VDC (nominal) (9840 W)
Input 0: 25 A @ –48 VDC (nominal) (1200 W)
Input 1 through 5: 180 A @ -–48 VDC (nominal)
(8640 W)
For each power supply, we recommend that you provision at least 56 A @ –48 VDC per input. Doing so enables you to operate the router in any configuration without upgrading the power infrastructure. Although Input 0 in the DC power supply requires less power, we recommend provisioning the same amount of power for each input to avoid the possibility of connecting the lower-powered DC cable to Input 1 through Input 5.
Circuit breaker current rating of 100 A per feed maximum shall be incorporated external to the equipment. The voltage rating of this breaker shall be 80 V minimum. For each power supply input, use a facility circuit breaker rated for 100 A (–48 VDC) maximum or
336 Copyright © 2013, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications as required by local code. You must provision a circuit breaker for each DC power supply input rated for at least 125% of the continuous current that the system draws at –48 VDC.
Related
Documentation
• T4000 Power System Description on page 43
• T4000 DC Power Supply Specifications on page 337
• T4000 DC Power Requirements on page 338
• T4000 DC Power Cable and Lugs Specifications on page 341
• T4000 DC Power Distribution on page 343
T4000 DC Power Supply Specifications
Table 47 on page 337 lists the DC power supply electrical specifications.
Table 47: Power Supply Electrical Specifications
Item Specification
DC input voltage
Input DC current rating (per input)
Nominal –48 VDC, –60 VDC
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops below -37.5 to -39.5 VDC, the router automatically shuts down. During automatic shutdown, the circuit remains active.
When the input voltage returns to –43.0 to
–44.00 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
Input 0: 45 A @ –48 VDC (nominal) (2160 W)
(54 A @ –40 VDC)
Input 1: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 2: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 3: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 4: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 5: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Related
Documentation
• T4000 Power System Description on page 43
• T4000 DC Power Requirements on page 338
• T4000 DC Power Cable and Lugs Specifications on page 341
Copyright © 2013, Juniper Networks, Inc.
337
T4000 Router Hardware Guide
• T4000 DC Power Distribution on page 343
T4000 DC Power Requirements
To allow for future growth so that you can operate the router in any hardware configuration without upgrading the power infrastructure, we recommend that you provision 56 A @
–48 VDC per input for the 60-A DC power cables connected to each power supply.
Table 48 on page 338 lists the power requirements for various hardware components when the router is operating under typical voltage conditions.
You can use the information in Table 48 on page 338 and the PIC requirements in T4000
Interface Module Reference to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples for a DC-powered router.
Table 48: Typical DC Power Requirements for T4000 Components
Component
Current
Requirement
(Amps @
–48 VDC)
Base system, not including FPCs and PICs (includes five SIB-I-T4000 SIBs, one host subsystem, one SCG, cooling system at normal speed, and craft interface) and two power supplies
30.8 A
Base system, not including FPCs and PICs (includes five TXP-LCC-3D SIBs, one host subsystem, one SCG, cooling system with FAN-R-TXP-3D-LCC rear fan tray at normal speed, and craft interface) and two power supplies
31.0 A
SIB-I-T4000 SIB
TXP-LCC-3D SIB
T1600 Enhanced Scaling FPC4
4.7 A
4.2 A
11.3 A
T4000 FPC5
Line-card chassis control board (LCC-CB)
C1800 Routing Engine
SCG
Redundant backup six-input DC power supply
Cooling system with FAN-REAR-TXP-LCC (normal speed)
Cooling system with FAN-REAR-TXP-LCC (full speed)
13.6 A
1.0 A
1.7 A
0.2 A
5.2 A
8.2 A
23.6 A
338 Copyright © 2013, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications
Table 48: Typical DC Power Requirements for T4000 Components
(continued)
Component
Current
Requirement
(Amps @
–48 VDC)
Cooling system with FAN-R-TXP-3D-LCC rear fan tray (normal speed)
Cooling system with FAN-R-TXP-3D-LCC rear fan tray (full speed)
9.5 A
26.7 A
Craft interface
PIC—Generalized typical value
PIC—Generalized maximum value
0.2 A
0.625 A
3.3 A
• Example of calculating power consumption for a minimum configuration:
Base System + 1 Type 4 FPC + 1 PIC
30.8 A + 11.3 A + 0.625 A = 42.7 A @ –48 VDC = 2050 W
• Example of calculating power consumption for a maximum configuration with eight
FPCs:
Base System + 1 LCC-CB + 1 RE-C1800 + 1 SCG + 8 T1600-Type 4 FPCs + 16 PICs +
(cooling system full speed - normal speed)
30.8 A + 1.0 A + 1.7 A + 0.2 A + 8 (11.3 A) + 16 (3.3 A) + (23.6 A - 8.2 A)
30.8 A + 1.0 A + 1.7 A + 0.2 A + A + 90.4 A + 52.8 A + 15.4 A = 192.3 A @ –48 VDC = 9230
W
• Current requirement adjustment for fans running at full speed (high temperature environment or cooling component failure):
Calculated system current (X) – Cooling (normal) + Cooling (full speed) =
X A – 6.7 A + 22 A = X A + 15.3 A
• Input current from a DC source other than –48 VDC (based on maximum configuration):
(–54 VDC input) x (input current X) = (–48 VDC) x (input current Y)
54 x X = 48 x 94.1 A
X = 48 x 94.1 A/54 = 83.6 A
• Example of calculating typical system thermal output for a configuration:
Watts DC/0.293 = BTU/hr
9230 W/0.293 = 31,501 BTU/hr
Related
Documentation
• T4000 DC Power System Electrical Specifications on page 336
• Overview of Preparing the Site for the T4000 Router on page 57
• T4000 DC Power Distribution on page 343
• T4000 Power System Description on page 43
Copyright © 2013, Juniper Networks, Inc.
339
T4000 Router Hardware Guide
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply)
For Junos OS Release 12.3 and later, the power management feature ensures that the router has enough power to support an FPC before the FPC is brought online. To configure the power management feature, see “Configuring DC Power on a T4000 Router” on page 148 . Depending on the type of FPCs installed, the router might not support a fully loaded chassis when you connect four 60-A DC power cables to a six 60-A input power supply.
If the power is underprovisioned for your hardware configuration, power management limits the number of FPCs brought online based on the following rules:
• When a T1600 Enhanced Scaling FPC4 (Model: T1600-FPC4-ES) is installed, the maximum number of FPCs that can be online is six.
• When there are no T1600-FPC4-ES installed, the maximum number of FPCs that can be online is seven.
For example, if there are six online FPCs and you insert a T1600-FPC4-ES, the power management feature will not power on the FPC.
NOTE: In the event of a chassis restart, master switchover, or router reboot, the power management feature powers on the FPCs based on the setting of the set chassis fru-poweron-sequence command.
CAUTION: If you do not configure the power management feature and you are connecting four 60-A DC power cables to the six-input power supply and the maximum power draw is exceeded, FRU states might change from Online to Offline or Present, or the interfaces might flap, or some traffic might drop.
Related
Documentation
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Configuring DC Power on a T4000 Router on page 148
• T4000 Power Management Overview
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply)
For Junos OS Release 12.3 and later, the power management feature ensures that the router has enough power to support an FPC before the FPC is brought online. To configure the power management feature, see “Configuring DC Power on a T4000 Router” on page 148 . Depending on the type of FPCs installed, the router might not support a fully loaded chassis when you connect three 80-A DC power cables to a six 60-A input power supply using terminal jumpers.
340 Copyright © 2013, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications
If the power is underprovisioned for your hardware configuration, power management limits the number of FPCs brought online based on the following rules:
• A maximum of six T1600 Enhanced Scaling FPC4 (Model: T1600-FPC4-ES) can be online.
• When one T1600-FPC4-ES is installed, a maximum of seven FPCs can be online.
• When there are no T1600-FPC4-ES installed, a maximum of eight FPCs (a fully loaded chassis) can be online.
For example, if there are seven online FPCs and you insert an T1600-FPC4-ES, the power management feature will not power on the FPC.
NOTE: In the event of a chassis restart, master switchover, or router reboot, the power management feature powers on the FPCs based on the setting of the set chassis fru-poweron-sequence command.
CAUTION: If you do not configure the power management feature and you are connecting three 80-A DC power cables to the six-input power supply and the maximum power draw is exceeded, FRU states might change from
Online to Offline or Present, or the interfaces might flap, or some traffic might drop.
Related
Documentation
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Configuring DC Power on a T4000 Router on page 148
• T4000 Power Management Overview
T4000 DC Power Cable and Lugs Specifications
• DC Power Cables on page 341
• DC Power Lugs on page 342
DC Power Cables
You must supply DC power cables that meet the following specifications: 4-AWG
(21.2 mm
2
), minimum 90°C wire, or as required by the local code.
Table 49 on page 341 summarizes the number of DC power cables required, which you must supply.
Table 49: DC Power Cables Required
Number of Inputs Connected Power Cables Required
5 10
Copyright © 2013, Juniper Networks, Inc.
341
T4000 Router Hardware Guide
Table 49: DC Power Cables Required
(continued)
Number of Inputs Connected Power Cables Required
6 12
WARNING: For field-wiring connections, use copper conductors only.
WARNING: DC Power cables must not block access to router components or drape where people could trip on them.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
DC Power Lugs
The accessory box shipped with the router includes cable lugs for 4-AWG (21.2 mm
2
) cable lugs. The cable lugs are dual hole, and sized to fit 1/4-20 UNC terminal studs at
15.86-mm (0.625-in.) center line.
Figure 148: DC Power Cable Lug
342
The cable lug shown in Figure 148 on page 342 is also used for the grounding the chassis.
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the power cables that you supply. A cable with an incorrectly attached lug can damage the router.
Related
Documentation
• T4000 Power System Description on page 43
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
Copyright © 2013, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Replacing a T4000 Six-Input DC Power Supply on page 257
• T4000 DC Power Electrical Safety Guidelines on page 320
T4000 DC Power Distribution
Most sites distribute DC power through a main conduit that leads to frame-mounted DC power distribution panels, one of which might be located at the top of the rack that houses the router. A pair of cables (one input and one return) connects each set of terminal studs to the power distribution panel.
NOTE: All inputs on the DC power supply in slot 0 must be powered by dedicated power feeds derived from feed A, and all inputs on the DC power supply in slot 1 must be powered by dedicated power feeds derived from feed
B. This configuration provides the commonly deployed A/B feed redundancy for the system.
Figure 149 on page 343 shows a typical DC source cabling arrangement.
Figure 149: Typical DC Source Cabling to the Router
PEM 0
Feed A
PEM 1
Central office
Primary & secondary
DC power distribution
Ground window
Central office ground
Rectifiers
Plant controls
Batteries
Battery plant
Feed B
AC
Central office
Primary & secondary
DC power distribution
Rectifiers
AC
Return (+)
Input (–)
Central office ground
Chassis grounding points
Ground window
CO ground
Central office ground
Plant controls
Batteries
Battery plant
Related
Documentation
• T4000 Power System Description on page 43
Copyright © 2013, Juniper Networks, Inc.
343
T4000 Router Hardware Guide
• Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 122
• Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 126
• Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 130
• Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs) on page 133
• Replacing a T4000 Six-Input DC Power Supply on page 257
• T4000 DC Power Electrical Safety Guidelines on page 320
344 Copyright © 2013, Juniper Networks, Inc.
APPENDIX E
T4000 Router Cable and Wire
Specifications, Pinouts, and Guidelines
• T4000 Network Cable Specifications and Guidelines on page 345
• T4000 Routing Engine Interface Cable Specifications on page 350
• T4000 Alarm Relay Contact Wire Specifications on page 350
• RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 351
• DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE
Ports on page 351
T4000 Network Cable Specifications and Guidelines
• Network Cable and Transceiver Overview for T Series Routers on page 345
• Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 347
• Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 348
Network Cable and Transceiver Overview for T Series Routers
Juniper Networks T Series Core Routers support a variety of fixed and pluggable transceivers and network cable, including multimode and single-mode fiber-optic cable.
For a list of transceivers, see Supported Network Interface Standards by Transceiver .
To determine which transceivers and network cables are supported in a particular PIC, see the “Cables and connectors” section in the Interface Module Reference for your router.
• T320 Interface Module Reference
• T640 Interface Module Reference
• T1600 Interface Module Reference
• T4000 Interface Module Reference
Copyright © 2013, Juniper Networks, Inc.
345
T4000 Router Hardware Guide
NOTE: We strongly recommend that only transceivers qualified for Juniper
Networks be used on Juniper Networks devices. Different transceiver types
(long-range, short-range, copper, and others) can be used together on multiport interface modules as long as they are qualified by Juniper Networks.
We cannot guarantee that the interface module will operate correctly if third-party transceivers are used.
• Ethernet Cables and Transceivers on page 346
• SONET/SDH Cables and Transceivers on page 346
Ethernet Cables and Transceivers
For Ethernet transceiver and cable specifications, see Table 50 on page 346 .
Table 50: Ethernet Specifications
Router Specification
T320, T640, and T1600 Routers
T320, T640, T1600, and T4000 Routers
T320, T640, T1600, and T4000 Routers
T320, T640, T1600, and T4000 Routers
T320, T640, T1600, and T4000 Routers
Fast Ethernet 100BASE-T Copper Interface Specifications
Fast Ethernet and Gigabit Ethernet Bidirectional SFP Optical Interface
Specifications
Gigabit Ethernet 1000BASE-T Copper Interface Specifications
Gigabit Ethernet 1000BASE Optical Interface Specifications
10-Gigabit Ethernet 10GBASE Optical Interface Specifications
T640 and T1600 Routers
T1600 and T4000 Routers
40-Gigabit Ethernet 40GBASE-R Optical Interface Specifications
100-Gigabit Ethernet 100GBASE-R Optical Interface Specifications
SONET/SDH Cables and Transceivers
For SONET/SDH transceiver and cable specifications, see Table 51 on page 346 .
Table 51: SONET/SDH Specifications
Router Specification
T320, T640, and T1600 routers SONET/SDH OC3/STM1 Optical Interface Specifications
T320, T640, and T1600 routers
T320, T640, T1600, and T4000 routers
T320, T640, T1600, and T4000 routers
T640, T1600, and T4000 routers
SONET/SDH OC12/STM4 Optical Interface Specifications
SONET/SDH OC48/STM16 Optical Interface Specifications
SONET/SDH OC192/STM64 Optical Interface Specifications
SONET/SDH OC768/STM256 Optical Interface Specifications
346 Copyright © 2013, Juniper Networks, Inc.
Appendix E: T4000 Router Cable and Wire Specifications, Pinouts, and Guidelines
Related
Documentation
• Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 348
• Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 347
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion
• Signal Loss in Multimode and Single-Mode Fiber-Optic Cable on page 347
• Attenuation and Dispersion in Fiber-Optic Cable on page 347
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable
Multimode fiber is large enough in diameter to allow rays of light to reflect internally
(bounce off the walls of the fiber). Interfaces with multimode optics typically use LEDs as light sources. LEDs are not coherent sources, however. They spray varying wavelengths of light into the multimode fiber, which reflects the light at different angles. Light rays travel in jagged lines through a multimode fiber, causing signal dispersion. When light traveling in the fiber core radiates into the fiber cladding, higher-order mode loss (HOL) results. Together these factors limit the transmission distance of multimode fiber compared with single-mode fiber.
Single-mode fiber is so small in diameter that rays of light can reflect internally through one layer only. Interfaces with single-mode optics use lasers as light sources. Lasers generate a single wavelength of light, which travels in a straight line through the single-mode fiber. Compared with multimode fiber, single-mode fiber has higher bandwidth and can carry signals for longer distances. It is consequently more expensive.
Exceeding the maximum transmission distances can result in significant signal loss, which causes unreliable transmission.
Attenuation and Dispersion in Fiber-Optic Cable
Correct functioning of an optical data link depends on modulated light reaching the receiver with enough power to be demodulated correctly.
Attenuation is the reduction in power of the light signal as it is transmitted. Attenuation is caused by passive media components, such as cables, cable splices, and connectors. While attenuation is significantly lower for optical fiber than for other media, it still occurs in both multimode and single-mode transmission. An efficient optical data link must have enough light available to overcome attenuation.
Dispersion is the spreading of the signal in time. The following two types of dispersion can affect an optical data link:
• Chromatic dispersion—Spreading of the signal in time resulting from the different speeds of light rays.
• Modal dispersion—Spreading of the signal in time resulting from the different propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor. However, at higher bit rates and over longer distances, chromatic dispersion rather than modal dispersion limits maximum link length.
Copyright © 2013, Juniper Networks, Inc.
347
T4000 Router Hardware Guide
An efficient optical data link must have enough light to exceed the minimum power that the receiver requires to operate within its specifications. In addition, the total dispersion must be less than the limits specified for the type of link in Telcordia Technologies document GR-253-CORE (Section 4.3) and International Telecommunications Union
(ITU) document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as a power penalty in the power budget. The optical power budget must allow for the sum of component attenuation, power penalties (including those from dispersion), and a safety margin for unexpected losses.
Related
Documentation
• Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 348
Calculating Power Budget and Power Margin for Fiber-Optic Cables
1.
Calculating Power Budget for Fiber-Optic Cable on page 348
2.
Calculating Power Margin for Fiber-Optic Cable on page 348
Calculating Power Budget for Fiber-Optic Cable
To ensure that fiber-optic connections have sufficient power for correct operation, you need to calculate the link's power budget, which is the maximum amount of power it can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at the worst-case levels. To calculate the worst-case estimate of power budget (P
B you assume minimum transmitter power (P
T
) and minimum receiver sensitivity (P
R
),
):
P
B
= P
T
– P
R
The following hypothetical power budget equation uses values measured in decibels
(dB) and decibels referred to one milliwatt (dBm):
P
B
= P
T
– P
R
P
B
= –15 dBm – (–28 dBm)
P
B
= 13 dB
Calculating Power Margin for Fiber-Optic Cable
After calculating a link's power budget you can calculate the power margin (P
M
), which represents the amount of power available after subtracting attenuation or link loss (LL) from the power budget (P
B
). A worst-case estimate of P
M assumes maximum LL:
P
M
= P
B
– LL
A P
M greater than zero indicates that the power budget is sufficient to operate the receiver.
Factors that can cause link loss include higher-order mode losses (HOL), modal and chromatic dispersion, connectors, splices, and fiber attenuation.
Table 52 on page 349 lists an estimated amount of loss for the factors used in the following sample calculations.
348 Copyright © 2013, Juniper Networks, Inc.
Appendix E: T4000 Router Cable and Wire Specifications, Pinouts, and Guidelines
For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.
Table 52: Estimated Values for Factors Causing Link Loss
Link-Loss Factor Estimated Link-Loss Value
Higher-order mode losses Single-mode—None
Multimode—0.5 dB
Modal and chromatic dispersion
Connector
Splice
Fiber attenuation
Single-mode—None
Multimode—None, if product of bandwidth and distance is less than 500 MHz-km
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
The following example uses the estimated values in Table 33 to calculate link loss (LL) for a 2-km-long multimode link with a power budget (P
B
) of 13 dB:
• Fiber attenuation for 2 km @ 1.0 dB/km= 2 dB
• Loss for five connectors @ 0.5 dB per connector = 5(0.5 dB) = 2.5 dB
• Loss for two splices @ 0.5 dB per splice =2(0.5 dB) = 1 dB
• Higher-order mode loss = 0.5 dB
• Clock recovery module = 1 dB
The power margin (P
M
) is calculated as follows:
P
M
= P
B
– LL
P
M
= 13 dB – 2 km (1.0 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB [HOL] – 1 dB [CRM]
P
M
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB – 1 dB
P
M
= 6 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
B
) of 13 dB uses the estimated values from Table 52 on page 349 to calculate link loss
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
M follows:
) is calculated as
P
M
= P
B
– LL
Copyright © 2013, Juniper Networks, Inc.
349
T4000 Router Hardware Guide
P
M
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
P
M
= 13 dB – 4 dB – 3.5 dB
P
M
= 5.5 dB
In both examples, the calculated power margin is greater than zero, indicating that the link has sufficient power for transmission and does not exceed the maximum receiver input power.
Related
Documentation
• Supported Network Interface Standards by Transceiver
• Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 347
T4000 Routing Engine Interface Cable Specifications
Table 53 on page 350 lists the specifications for the cables that connect to the management ports on the connector interface panel (CIP).
Table 53: Cable Specifications for Routing Engine Management
Port Cable Specification Cable/Wire Supplied
Maximum
Length
Router
Receptacle
6 ft (1.83 m) DB-9 male Routing Engine console or auxiliary interface
Routing Engine
Ethernet interface
RS-232 (EIA-232) serial cable
One 6-ft (1.83-m) length with
DB-9/DB-9 connectors
Category 5 cable or equivalent suitable for 100Base-T operation
One 15-ft (4.57-m) length with
RJ-45/RJ-45 connectors
328 ft
(100 m)
RJ-45 autosensing
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Connecting the T4000 Router to a Management Ethernet Device on page 118
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
• DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 351
• RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 351
T4000 Alarm Relay Contact Wire Specifications
For management and service operations, you can connect the router to external alarm-reporting devices through the alarm relay contacts on the CIP. You must provide a wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
).
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
350 Copyright © 2013, Juniper Networks, Inc.
Appendix E: T4000 Router Cable and Wire Specifications, Pinouts, and Guidelines
• Connecting the T4000 Router to an External Alarm-Reporting Device on page 114
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port
The port on the CIP labeled ETHERNET is an autosensing 10/100-Mbps Ethernet Ethernet
RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing Engine to a management LAN (or other device that supports out-of-band management).
Table 54 on page 351 describes the RJ-45 connector pinouts.
Table 54: RJ-45 Connector Pinouts
Pin Signal
1 TX+
4
5
2
3
6
7
8
TX –
RX+
Termination network
Termination network
RX–
Termination network
Termination network
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• Connecting the T4000 Router to a Management Ethernet Device on page 118
• T4000 Routing Engine Interface Cable Specifications on page 350
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports
The ports on the CIP labeled AUXILIARY and CONSOLE are DB-9 receptacles that accept
RS-232 (EIA-232) cable. The AUXILIARY port connects the Routing Engine to a laptop, modem, or other auxiliary unit, and the CONSOLE port connects it to a management console. The ports are configured as data terminal equipment (DTE).
Table 55 on page 351 describes the DB-9 connector pinouts.
Table 55: DB-9 Connector Pinouts
Pin Signal Direction Description
1
2
DCD
RxD
<–
<–
Carrier Detect
Receive Data
Copyright © 2013, Juniper Networks, Inc.
351
T4000 Router Hardware Guide
7
8
9
5
6
3
4
Table 55: DB-9 Connector Pinouts
(continued)
Pin Signal Direction Description
TxD
DTR
Ground
DSR
–>
–>
—
<–
Transmit Data
Data Terminal Ready
Signal Ground
Data Set Ready
RTS
CTS
RING
–>
<–
<–
Request To Send
Clear To Send
Ring Indicator
Related
Documentation
• T4000 Connector Interface Panel (CIP) Description on page 27
• T4000 Routing Engine Interface Cable Specifications on page 350
• Connecting the T4000 Router to a Management Console or Auxiliary Device on page 112
352 Copyright © 2013, Juniper Networks, Inc.
APPENDIX F
Contacting Customer Support and
Returning Router Hardware
• Contacting Customer Support on page 353
• Returning a Hardware Component to Juniper Networks, Inc. on page 354
• Tools and Parts Required to Remove Components from a T4000 Router on page 355
• Packing the T4000 Router for Shipment on page 355
• Packing the T4000 Router Components for Shipment on page 356
• Displaying T4000 Component Serial Numbers on page 357
• T4000 Component Serial Number Locations on page 358
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: http://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 11-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
When requesting support from JTAC by telephone, be prepared to provide the following information:
• Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
• Configuration data using one or more of the show commands
Copyright © 2013, Juniper Networks, Inc.
353
T4000 Router Hardware Guide
Related
Documentation
• Returning a Hardware Component to Juniper Networks, Inc. on page 354
Returning a Hardware Component to Juniper Networks, Inc.
If a problem cannot be resolved by the JTAC technician, a Return Materials Authorization
M01i (RMA) is issued. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
NOTE: Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments will be returned to the customer by collect freight.
For more information about return and repair policies, see the customer support Web page at http://www.juniper.net/support/guidelines.html
.
For product problems or technical support issues, contact the Juniper Networks Technical
Assistance Center (JTAC) using the Case Manager link at http://www.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the
United States).
To return a hardware component:
1.
Determine the part number and serial number of the component.
2.
Obtain an RMA number from the Juniper Networks Technical Assistance Center (JTAC).
You can send e-mail or telephone as described above.
3.
Provide the following information in your e-mail message or during the telephone call:
• Part number and serial number of component
• Your name, organization name, telephone number, and fax number
• Description of the failure
4.
The support representative validates your request and issues an RMA number for return of the component.
5.
Pack the component for shipment.
Related
Documentation
• Contacting Customer Support on page 353
• Guidelines for Packing Router Components for Shipment
354 Copyright © 2013, Juniper Networks, Inc.
Appendix F: Contacting Customer Support and Returning Router Hardware
Tools and Parts Required to Remove Components from a T4000 Router
To remove components from the router or the router from a rack, you need the following tools and parts:
• 2.5-mm flat-blade (–) screwdriver, for detaching alarm relay terminal block
• 7/16-in. (11 mm) nut driver
• Blank panels to cover empty slots
• Electrostatic bag or antistatic mat, for each component
• Electrostatic discharge (ESD) grounding wrist strap
• Flat-blade (–) screwdriver
• Mechanical lift, if available
• Phillips (+) screwdrivers, numbers 1 and 2
• Rubber safety caps for fiber-optic transceivers and cable
Related
Documentation
• Tools and Parts Required for Replacing T4000 Hardware Components on page 217
• Packing the T4000 Router Components for Shipment on page 356
• Packing the T4000 Router for Shipment on page 355
Packing the T4000 Router for Shipment
To pack the router for shipment:
1.
Retrieve the shipping crate and packing materials in which the router was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
On the console or other management device connected to the master Routing Engine, enter CLI operational mode. To power off the router, see “Powering Off the T4000
Router” on page 142 .
4.
Disconnect power from the router. .
5.
Remove the cables that connect to all external devices. For instructions, see “Removing a T4000 Management Ethernet Cable” on page 226 , “Removing a T4000 Console or
Auxiliary Cable” on page 224 , and “Replacing the T4000 Alarm Relay Wires” on page 224 .
6.
Remove all field replaceable units (FRUs) from the router.
7.
Remove the router from the rack:
Copyright © 2013, Juniper Networks, Inc.
355
T4000 Router Hardware Guide
• If you are using a mechanical lift, place the lift platform under the router, unscrew and remove the mounting screws from the rack, and move the router to the shipping crate.
• If you are not using a mechanical lift:
• If the router weight is fully supported by a shelf or another router, unscrew and remove the mounting screws from the rack. Four people can then lift the router and move it to the shipping crate.
• If the router weight is not fully supported by a shelf or another router, four people should grasp the router while another person unscrews and removes the mounting screws from the rack. The lifters can then move the router to the shipping crate.
8.
Place the router into the shipping crate or onto the pallet. If on a pallet, bolt the router to the pallet.
9.
Cover the router with an ESD bag, and place packing foam on top of and around the router.
10.
Replace the accessory box on top of the packing foam.
11.
Securely tape the box closed or place the crate cover over the router.
12.
Write the Return Materials Authorization (RMA) number on the exterior of the box to ensure proper tracking.
Related
Documentation
• Contacting Customer Support on page 353
• Preventing T4000 Electrostatic Discharge Damage on page 296
Packing the T4000 Router Components for Shipment
To pack and ship individual components:
• When you return components, make sure they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
• Use the original shipping materials if they are available.
• Place individual boards in electrostatic bags.
• Write the Return Materials Authorization (RMA) number on the exterior of the box to ensure proper tracking.
CAUTION: Do not stack any of the router components.
Related
Documentation
• Contacting Customer Support on page 353
• Displaying T4000 Component Serial Numbers on page 357
• T4000 Component Serial Number Locations on page 358
356 Copyright © 2013, Juniper Networks, Inc.
Appendix F: Contacting Customer Support and Returning Router Hardware
• Returning a Hardware Component to Juniper Networks, Inc. on page 354
Displaying T4000 Component Serial Numbers
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization
(RMA), you must find the serial number on the router or component. To list all of the router components and their serial numbers, enter the following command-line interface
(CLI) command: user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN11B7FECAHA T4000
Midplane REV 01 710-027486 RC9244 T-series Backplane
FPM GBUS REV 13 710-002901 BBAF3545 T640 FPM Board
FPM Display REV 03 710-021387 BBAF4338 T4000 FPM Display
CIP REV 06 710-002895 BBAF2353 T-series CIP
PEM 0 REV 02 740-036442 VG00017 Power Entry Module 6x60
SCG 0 REV 18 710-003423 BBAE4908 T640 Sonet Clock Gen.
SCG 1 REV 18 710-003423 BBAB2590 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-1800
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-1800
CB 0 REV 09 710-022597 EF6057 LCC Control Board
CB 1 REV 09 710-022597 EF9180 LCC Control Board
FPC 4 REV 05 750-010153 EE9812 FPC Type 5-3D
CPU REV 06 711-030686 EE8534 SNG PMB
PIC 0 REV 07 750-034624 EF6805 12x10GE (LAN/WAN) SFPP
Xcvr 1 REV 01 740-031980 123363A01143 SFP+-10G-SR
PIC 1 REV 02 750-034624 EE3717 12x10GE (LAN/WAN) SFPP
Xcvr 1 REV 01 740-031980 123363A01301 SFP+-10G-SR
Xcvr 4 REV 01 740-031981 UHP016G SFP+-10G-LR
Xcvr 6 REV 01 740-031980 B10M03384 SFP+-10G-SR
Xcvr 7 REV 01 740-031980 AJJ032B SFP+-10G-SR
Xcvr 9 REV 01 740-031980 AJJ03C5 SFP+-10G-SR
Xcvr 10 REV 01 740-031980 AJJ037Y SFP+-10G-SR
Xcvr 11 REV 01 740-031980 AJJ01LW SFP+-10G-SR
LMB 0 REV 04 711-034381 EE8796 Galaxy FPC LU Mezzanine
Board
LMB 1 REV 03 711-035774 EE8818 Type-1 LU Mezzanine Board
LMB 2 REV 04 711-034381 EE8795 Galaxy FPC LU Mezzanine
Board
FPC 6 REV 26 750-032819 EH3173 FPC Type 5-3D
CPU REV 10 711-030686 EG7759 SNG PMB
PIC 0 REV 08 50-035293 EG2430 1x100GE
Xcvr 0 REV 01 740-032210 C22CTQB CFP-100G-LR4
PIC 1 REV 03 750-035293 EF3655 1x100GE
Xcvr 0 REV 01 740-032210 C22CQXC CFP-100G-LR4
LMB 0 REV 05 711-034381 EG6370 Galaxy FPC LU Mezzanine
Board
LMB 1 REV 04 711-035774 EG6503 Type-1 LU Mezzanine Board
LMB 2 REV 05 711-034381 EG6374 Galaxy FPC LU Mezzanine
Board
FPC 7 REV 24 750-032819 EG9191 FPC Type 5-3D
CPU REV 10 711-030686 EG7776 SNG PMB
PIC 0 REV 07 750-034624 EF6808 12x10GE (LAN/WAN) SFPP
Xcvr 0 REV 01 740-031980 B10M01418 SFP+-10G-SR
Copyright © 2013, Juniper Networks, Inc.
357
T4000 Router Hardware Guide
Xcvr 1 REV 01 740-031981 UK60DPC SFP+-10G-LR
Xcvr 2 REV 01 740-031980 AJJ01QE SFP+-10G-SR
Xcvr 3 REV 01 740-031980 B10M03379 SFP+-10G-SR
Xcvr 4 REV 01 740-031980 B10M01541 SFP+-10G-SR
Xcvr 5 REV 01 740-031980 B10M03333 SFP+-10G-SR
Xcvr 6 REV 01 740-031980 B10M03344 SFP+-10G-SR
Xcvr 7 REV 01 740-031980 AJJ0399 SFP+-10G-SR
Xcvr 8 REV 01 740-031980 AJJ0339 SFP+-10G-SR
Xcvr 9 REV 01 740-031980 B10M00112 SFP+-10G-SR
Xcvr 10 REV 01 740-031981 UHP0168 SFP+-10G-LR
Xcvr 11 REV 01 740-031980 B10M00452 SFP+-10G-SR
PIC 1 REV 01 750-035293 EE2286 1x100GE
Xcvr 0 REV 01 740-032210 C22CR7E CFP-100G-LR4
LMB 0 REV 03 711-034381 ED8127 Galaxy FPC LU Mezzanine
Board
LMB 1 REV 02 711-035774 EE2480 Type-1 LU Mezzanine Board
LMB 2 REV 03 711-034381 EE3034 Galaxy FPC LU Mezzanine
Board
SPMB 0 REV 05 710-023321 EF9671 LCC Switch CPU
SPMB 1 REV 05 710-023321 EF6092 LCC Switch CPU
SIB 0 REV 07 711-036340 EG2276 SIB-HC-3D
SIB 1 REV 07 711-036340 EG2299 SIB-HC-3D
SIB 2 REV 07 711-036340 EG2302 SIB-HC-3D
SIB 3 REV 02 711-036340 EE6290 SIB-HC-3D
SIB 4 REV 02 711-036340 EF1319 SIB-HC-3D
Fan Tray 0 Front Top Fan Tray --
Rev 2
Fan Tray 1 Front Bottom Fan Tray
Rev 2
Fan Tray 2 Rear Fan Tray -- Rev 3
Related
Documentation
• Contacting Customer Support on page 353
• T4000 Component Serial Number Locations on page 358
• Returning a Hardware Component to Juniper Networks, Inc. on page 354
T4000 Component Serial Number Locations
Most components have a small serial number ID label attached to the component body.
For example, many components have a rectangular serial number label as shown in
Figure 150 on page 358 .
Figure 150: Serial Number ID Label
• CIP Serial Number Label on page 359
• Control Board Serial Number Label on page 359
• Craft Interface Serial Number Label on page 360
• FPC Serial Number Label on page 360
• PIC Serial Number Label on page 361
• Power Supply Serial Number Label on page 362
358 Copyright © 2013, Juniper Networks, Inc.
Appendix F: Contacting Customer Support and Returning Router Hardware
• Routing Engine Serial Number Label on page 362
• SCG Serial Number Label on page 363
• SIB Serial Number Label on page 363
CIP Serial Number Label
The serial number label is located at the top of the left side of the CIP (see
Figure 151 on page 359 ).
Figure 151: CIP Serial Number Label
Control Board Serial Number Label
The LCC-CB serial number is located on the lower right side of the control board (see
Figure 152 on page 359 ).
Figure 152: LCC-CB Serial Number Label
Copyright © 2013, Juniper Networks, Inc.
359
T4000 Router Hardware Guide
Craft Interface Serial Number Label
Figure 153: Craft Interface Serial Number ID Label
T Series
FAIL
FPC0
OK
FAIL
ACO/LT
FPC1
OK
MENU
ENTER
FAIL
FPC2
OK
FAIL
FPC3
OK
FAIL
FPC4
OK
FAIL
FPC5
OK
FAIL
OK MASTER
HOST0
FAIL
OK
HOST1
MASTER
SIB0
FAIL OK
SIB1
SIB2
SIB3
SIB4
FAIL
FPC6
OK
FAIL
FPC7
OK
AA1234
Serial number ID label
FPC Serial Number Label
The location of the serial number label varies depending on the FPC:
• T1600 Type 4 FPCs: located on the lower right side
• T4000 Type 5 FPCs: located on the upper middle.
Figure 154 on page 360 shows the serial number location for a T1600 Type 4 FPC.
Figure 154: Serial Number Label on a T1600 Type 4 FPC
360
Figure 155 on page 361 shows the serial number location for a T4000 Type 5 FPC.
Copyright © 2013, Juniper Networks, Inc.
Appendix F: Contacting Customer Support and Returning Router Hardware
Figure 155: Type 5 FPC Serial Number ID Label
Serial number ID label
12V
300W
PIC Serial Number Label
The exact location serial number label is different on different PICs, depending on the placement of components on the PIC board. In this example, the serial number label is located on the right side of the PIC (see Figure 156 on page 362 ), when the PIC is vertically oriented (as it would be installed in the router).
Copyright © 2013, Juniper Networks, Inc.
361
T4000 Router Hardware Guide
Figure 156: PIC Serial Number Label
Power Supply Serial Number Label
For the DC power supply, the serial number label is located on the lower left side of the faceplate. (see Figure 157 on page 362 ).
Figure 157: DC Power Supply Serial Number Label
Serial number ID label
Routing Engine Serial Number Label
The serial number label is located on the left side (see Figure 158 on page 363 ).
362 Copyright © 2013, Juniper Networks, Inc.
Appendix F: Contacting Customer Support and Returning Router Hardware
Figure 158: Routing Engine
Serial number
ID label
P737F -
SCG Serial Number Label
The serial number is located on the top of the SCG, close to the midplane connector (see
Figure 159 on page 363 ).
NOTE: Although the illustration shows the SCG with DB-9 ports, the serial number location is the same for the SCG with RJ-48 ports.
Figure 159: SCG Serial Number Label
SIB Serial Number Label
The serial number is located on the right side behind the faceplate (see
Figure 160 on page 364 ).
Copyright © 2013, Juniper Networks, Inc.
363
T4000 Router Hardware Guide
Figure 160: SIB Serial Number ID Label
Serial number ID label
Related
Documentation
• Displaying T4000 Component Serial Numbers on page 357
364 Copyright © 2013, Juniper Networks, Inc.
PART 6
Index
• Index on page 367
Copyright © 2013, Juniper Networks, Inc.
365
T4000 Router Hardware Guide
366 Copyright © 2013, Juniper Networks, Inc.
Index
Symbols
#, comments in configuration statements..................
xxii
( ), in syntax descriptions...................................................
xxii
< >, in syntax descriptions..................................................
xxii
[ ], in configuration statements.......................................
xxii
{ }, in configuration statements.......................................
xxii
| (pipe), in syntax descriptions.........................................
xxii
A
accessory box parts list.............................................................................
63 agency approvals.................................................................
324 air filters maintaining....................................................................
180 replacing................................................................
218 , 220 alarm messages.........................................................................
191 alarms handling by Routing Engine..................................
8 , 39 mode for LCD...................................................................
24 relay contacts..................................................................
29 temperature, displaying.............................................
193 altitude, acceptable range................................................
333 antistatic mat, using...........................................................
296 approvals, agency................................................................
324 architecture data flow..............................................................................
9
Packet Forwarding Engines..........................................
9
ASICs
Layer2/Layer 3 Packet Processing ASIC..................
9
Queuing and Memory Interface ASIC.......................
9
Switch Interface ASIC.....................................................
9
T Series Internet Processor...........................................
9 attenuation in fiber-optic cable......................................
347 auxiliary port (for Routing Engine management) cable connection during initial installation.............
112 connector pinouts (DB-9)................................
351
B
battery environmental compliance.....................................
328 handling warning........................................................
309 lithium..............................................................................
328 braces, in configuration statements...............................
xxii brackets angle, in syntax descriptions....................................
xxii square, in configuration statements......................
xxii
C
cable
Ethernet port (for Routing Engine management) connecting during initial installation.............
118 fiber-optic cleaning instructions for transceivers..........
185
PIC maintaining............................................................
185 cable management system fiber-optic cable, use with........................................
185 cables auxiliary or console port (for Routing Engine management) connecting during initial installation.............
112 fiber-optic attenuation............................................................
347 dispersion...............................................................
347 multimode and single-mode..........................
347 transmission distance, maximum................
347 wavelength ranges.............................................
347 case number, for JTAC........................................................
353 chassis..........................................................................................
15 alarm messages See alarm, messages
ESD points.........................................................................
15 grounding points.............................................................
15 installing in rack..............................................................
79 weight...............................................................................
331 chromatic dispersion in fiber-optic cable...................
347
CIP alarm relay contacts.....................................................
29
Class 1 laser warning...........................................................
306
Class 1 LED warning.............................................................
307 cleaning instructions fiber-optic transceivers..............................................
185
Copyright © 2013, Juniper Networks, Inc.
367
T4000 Router Hardware Guide
CLI as troubleshooting tool.............................................
189 command to display chassis alarm messages...............
191 to display FPC status.........................................
184 to display PIC status..........................................
184 to display serial number...................................
357 commands ping....................................................................................
189 show chassis alarms....................................................
191 show chassis fpc for FPC status.......................................................
184 show chassis fpc pic-status....................................
184 show chassis hardware.............................................
357 traceroute.......................................................................
189 comments, in configuration statements......................
xxii compatibility, electromagnetic........................................
318 compliance
EMC (electromagnetic compatibility) requirements (Canada)
....................................................................................
327
EMC requirements (European
Community)..............................................................
326
EMC requirements (Japan).....................................
328
EMC requirements (United States)......................
328 general standards.......................................................
324 components chassis.................................................................................
15 cooling system.................................................................
21 field replacement.........................................................
216
FPCs....................................................................................
30 host subsystem...............................................................
35 midplane............................................................................
18 packing for shipment.................................................
356
PICs......................................................................................
42 power supplies................................................................
43 redundancy........................................................................
15
SCG.....................................................................................
49
SIBs.....................................................................................
46 weight...............................................................................
331 configuration files, storage by Routing Engine..........................
8 , 40 console port (for Routing Engine management) cable connection during initial installation.............
112 connector pinout (DB-9)..................................
351 control boards maintaining.....................................................................
183 conventions notice icons......................................................................
xxi text and syntax..............................................................
xxii cooling system description.........................................................................
21 troubleshooting.............................................................
193 copper conductors warning (DC power)......................
321 curly braces, in configuration statements....................
xxii customer support.................................................................
xxiii contacting......................................................................
353 contacting JTAC............................................................
xxiii
D
DB-9 cable connector pinouts (auxiliary and console ports).....................................................................................
351
DC power copper conductors warning......................................
321 disconnection warning................................................
317 grounding equipment warning................................
315 grounding requirements warning...........................
315 power supplies disconnection warning...............
316 removal warning...........................................................
321 requirements for four 60-A Inputs.......................
340 requirements for hardware components...........
338 requirements for three 80-A Inputs....................
340 specifications.................................................................
341 wiring terminations warning....................................
323
DC power cables lugs.....................................................................................
341 specifications.................................................................
341
DC power configuration five 60-A inputs............................................................
148 four 60-A inputs...........................................................
149 three 80-A inputs........................................................
150
DC power connections five 60-A inputs............................................................
126 four 60-A inputs...........................................................
130 six 60-A inputs...............................................................
122 three 80-A inputs.........................................................
133
DC power supplies multiple disconnection warning.............................
316
DC power supply cables See DC power cables dispersion in fiber-optic cable.........................................
347 documentation comments on................................................................
xxiii
368 Copyright © 2013, Juniper Networks, Inc.
Index
E
earthquakes site preparation for........................................................
58 tested toleration for seismic....................................
333
EIA rack standards.................................................................
58 electricity safety warnings.............................................................
315 site wiring guidelines...................................................
318 electromagnetic compatibility See EMC (electromagnetic compatibility) pulse..................................................................................
318 electrostatic bag using to store components.....................................
296
EMC (electromagnetic compatibility) compliance with requirements (Canada)..........
327 compliance with requirements (European
Community)..............................................................
326 compliance with requirements (Japan).............
328 compliance with requirements (United
States)........................................................................
328 standards........................................................................
324 suppression....................................................................
318
EMP (electromagnetic pulse)..........................................
318 environmental specifications..........................................
333
ESD preventing damage to components by..............
296
Ethernet port (for Routing Engine management) cable connection during initial installation.............
118
ETSI rack standards...............................................................
58
F
fan trays description.........................................................................
21 maintaining......................................................................
181 replacing.........................................................................
236 troubleshooting.............................................................
193 fiber-optic power budget calculation........................................
348 fiber-optic cable See cable, fiber-optic field-replaceable units........................................................
216 fire safety requirements.....................................................
299
Flexible PIC Concentrators See FPCs font conventions....................................................................
xxii
FPCs.............................................................................................
30 components....................................................................
30 maintenance..................................................................
184 replacing..........................................................................
242 status, checking.................................................
184 , 200 troubleshooting...........................................................
200 types...................................................................................
34
G
grounding equipment warning.....................................................
315 requirements warning.................................................
315 grounding (electrical) specifications
DC-powered router.....................................................
335 grounding cables lug......................................................................................
335 guidelines electrical cable and wiring........................................
318 safety ...............................................................................
293
H
hardware components power requirements...................................................
338 higher-order mode loss (HOL)........................................
347 host subsystem description........................................................................
35 hot-pluggable components, description.....................
216 humidity (relative), acceptable.......................................
333
I
immunity standards............................................................
324 installation parts received, verifying...............................................
63
PICs, connecting............................................................
116 installation handle remove...............................................................................
82 installation instructions alarm relay contact wires during initial installation.....................................
114 cable, auxiliary or console port (for Routing
Engine management) during initial installation.....................................
112 cable, Ethernet port (for Routing Engine management) during initial installation....................................
118 installation warning..............................................................
301 instructions cleaning See cleaning instructions maintenance
PIC.............................................................................
184 packing router for shipment............................................
355
Copyright © 2013, Juniper Networks, Inc.
369
T4000 Router Hardware Guide interface network.................................................
345 , 347 See PIC interference electromagnetic............................................................
318 radio frequency.............................................................
318
J
jewelry removal warning....................................................
310
Junos OS modularity and scalability.....................................
8 , 39
L
laser beam warning...............................................................
307
Class 1 laser warning..................................................
306 laser safety guidelines........................................................
305
LCD on craft interface alarm mode......................................................................
24
LEDs
Class 1 LED warning....................................................
307 safety warnings.................................................
305 , 306
SCG.......................................................................................
51
SIB........................................................................................
27 sonet clock generator....................................................
51 lightning activity warning....................................................
311 link loss, calculating............................................................
348 lithium battery compliance..............................................
328 lug for grounding cables....................................................
335 lugs for DC power cables....................................................
341
M
maintaining air filters...........................................................................
180 control boards...............................................................
183 fan trays............................................................................
181
LCC-CBs...........................................................................
183
SIBs...................................................................................
186 maintenance guidelines cable
PIC.............................................................................
185
FPC....................................................................................
184
PIC......................................................................................
184 warnings.........................................................................
309 manuals comments on................................................................
xxiii midplane.....................................................................................
18 description.........................................................................
18 functions............................................................................
18 midplane energy hazard warning....................................
316 modal dispersion in fiber-optic cable...........................
347 mode loss, higher-order.....................................................
347 multimode fiber-optic cable See cables, fiber-optic
N
NEBS standards....................................................................
324 network cable See cable, fiber-optic; cable, PIC notice icons...............................................................................
xxi
O
open-frame rack See rack operating temperature warning.......................................
312
P
Packet Forwarding Engines architecture and data flow...........................................
9 parentheses, in syntax descriptions...............................
xxii
PEMs see power supplies....................................................
43
PIC maintenance..................................................................
184
SONET/SDH alarm messages....................................................
191 analyzer, use of.....................................................
185 status, checking............................................................
184 troubleshooting...........................................................
208
PICs..............................................................................................
42 connecting.......................................................................
116 description........................................................................
42 replacing..........................................................................
253 status, checking...........................................................
200 ping command.......................................................................
189 pinouts
DB-9 cable connector ports
(auxiliary/console)..................................................
351 power................................................................................
122 , 148 budget calculation......................................................
348
DC power management.........................................
340 requirements for hardware components.....................................................
338 disconnection warning (DC power).......................
317 margin calculation......................................................
348 surges................................................................................
318
See also DC power configuration
See also DC power connections power supplies cables See DC power cables description........................................................................
43 powering off router...............................................................
142
370 Copyright © 2013, Juniper Networks, Inc.
Index product disposal warning...................................................
313
Q
qualified personnel warning............................................
294
R
rack front-mount flange hole spacing............................
58 mounting bracket hole spacing................................
58 securing to building.......................................................
58 size and strength required..........................................
58 standards, EIA and ETSI..............................................
58 rack mounting warning.......................................................
301 radiation warning.................................................................
308 radio frequency interference, preventing.....................
318 ramp warning........................................................................
305 redundancy................................................................................
15 relative humidity, acceptable...........................................
333 replacing air filters..................................................................
218 , 220 fan trays..........................................................................
236
FPCs..................................................................................
242
PICs...................................................................................
253
SIB-I-T4000..................................................................
279
SIB-TXP-LCC-3D.........................................................
282 requirements fire safety........................................................................
299 restricted access warning.................................................
294
RFI (radio frequency interference).................................
318 router parts list.............................................................................
63 weight...............................................................................
331
Routing Engine alarm handling by.....................................................
8 , 39 configuration files, storage....................................
8 , 40 packet counting.........................................................
8 , 39 routing table maintenance..........................................
8 , 39
S
safety guidelines general.............................................................................
293 safety standards...................................................................
324 safety warnings.....................................................................
294
See also warnings
SCGs components....................................................................
49 description........................................................................
49
LEDs.....................................................................................
51 seismic earthquake..............................................................
333 serial number in output from show chassis hardware command...................................................................
357 shipping crate repacking........................................................................
355 show chassis alarms command..............................
191 , 193 show chassis fpc command for FPC status................................................................
184 show chassis fpc detail command...............................
200 show chassis fpc pic-status command.......................
184 show chassis hardware command................................
357
SIB-I-T4000 description.......................................................................
46 maintaining....................................................................
186 replacing..........................................................................
279
SIB-TXP-3D-LCC description........................................................................
47
SIB-TXP-LCC-3D replacing.........................................................................
282
SIBs description.......................................................................
46
LEDs.............................................................................
27 , 48 maintaining....................................................................
186 replacing SIB-I-T4000 SIBs....................................
279 replacing TXP-LCC-3D SIBs....................................
282
SIB-I-T4000 components.........................................
46
SIB-TXP-3D-LCC components.................................
47 troubleshooting...........................................................
209 signal dispersion...................................................................
347 signaling, distance limitations..........................................
318 single-mode fiber-optic cable See cables, fiber-optic site electrical wiring guidelines.......................................
318 environmental specifications.................................
333
SONET Clock Generators See SCGs
SONET/SDH analyzer, use of...........................................
185 specifications cable.......................................................................
345 , 347 power.......................................................................
341
See also cable, PIC environmental...............................................................
333 power drawn by hardware components.................
338 power system...............................................................
338 rack connection to building structure.....................
58 front-mount flange hole spacing....................
58
Copyright © 2013, Juniper Networks, Inc.
371
T4000 Router Hardware Guide mounting bracket hole spacing.......................
58 size and strength...................................................
58 thermal output.............................................................
333 standards compliance........................................................
324 support, technical See technical support surge protection.....................................................................
318
Switch Interface ASIC..............................................................
9
Switch Interface Boards See SIBs syntax conventions...............................................................
xxii
T
T Series Internet Processor...................................................
9 technical support contacting JTAC............................................................
xxiii telco rack See rack temperature, acceptable range......................................
333 thermal output......................................................................
333 tolerances................................................................................
333 tools required chassis returning for repair or replacement..............
355 hardware components returning for repair or replacement..............
355 replacement....................................................................
217 traceroute command..........................................................
189 transmission distances, fiber-optic cable...................
347 troubleshooting
CLI commands..............................................................
189 cooling system..............................................................
193 fans....................................................................................
193
FPCs.................................................................................
200
PIC....................................................................................
208
SIBs..................................................................................
209
U
U (rack unit)..............................................................................
58
W
warnings battery handling..........................................................
309
Class 1 laser...................................................................
306
Class 1 LED.....................................................................
307 copper conductors (DC power)..............................
321 electrical...........................................................................
315 grounding.........................................................................
315 grounding equipment ................................................
315 installation......................................................................
301 jewelry removal.............................................................
310 laser and LED.....................................................
305 , 306 laser beam......................................................................
307 levels defined.................................................................
291 lightning activity.............................................................
311 maintenance and operational...............................
309 midplane energy hazard ...........................................
316 multiple power supplies disconnection...............
316 operating temperature...............................................
312 power disconnection...................................................
317 power removal...............................................................
321 product disposal...........................................................
313 qualified personnel.....................................................
294 rack mounting...............................................................
301 radiation.........................................................................
308 ramp.................................................................................
305 restricted access..........................................................
294 wiring terminations (DC power)............................
323 wavelength ranges supported by fiber-optic cable......................................................................................
347 wiring electrical See electricity terminations warning (DC power)........................
323