Honeywell VNT5150E1000 159 CFM TrueFRESH Energy Recovery Ventilation System - For Homes Up to 3,150 Sq Ft Spec Sheet
Add to My manuals2 Pages
advertisement
![Honeywell VNT5150E1000 159 CFM TrueFRESH Energy Recovery Ventilation System - For Homes Up to 3,150 Sq Ft Spec Sheet | Manualzz Honeywell VNT5150E1000 159 CFM TrueFRESH Energy Recovery Ventilation System - For Homes Up to 3,150 Sq Ft Spec Sheet | Manualzz](http://s3.manualzz.com/store/data/024201361_1-248733940204a3678a3e11a8f9efdd96-360x466.png)
VNT5150E1000
Ventilation System
SPECIFICATION DATA
VNT5150E Capacities and Performance
Part Number: VNT5150E1000
Product Weight: 42 lbs (19 Kg)
Input Voltage:
Input Current:
120 VAC; 60 Hz.
1.5 A
Output Power to Terminals
Operating Ranges:
Temp:
Humidity:
CFM:
Type of Heat
Exchanger:
5 VDC, 1.0 A
34–135 ºF (1.1–57.2 ºC)
0-99% RH
30–160
Cross-flow (Enthalpic)
Exchange Surface: 85 sq. ft.
Energy Core Dimensions:
Width: 10 in. (381 mm)
Height:
Length:
12 in. (305 mm)
12 in. (305 mm)
Filter Dimensions:
Height:
Width:
12 in. (305 mm)
10 in. (254 mm)
Shipping Specs:
Length:
Height:
Width:
Weight:
27.5 in. (698 mm)
13.4 in. (340 mm)
25.8 in. (656 mm)
47.5 lbs (21.55 Kg)
Defrost Type:
Drain Tubing
Diameter
Evacuation
1/2 in. (12.7 mm)
Flexible Duct (2):
6 in. round for inlet and outlet. Flexible vinyl, compatible for connection to rigid or flexible ducting with sheet metal screws and/or tape.
Cabinet:
20 gauge galvanized steel powder-coat painted.
Certification:
QPS, SGSUSTC, ARI 1060
Conforms to UL Std. 1812.
Install the unit according to National Electric
Codes.
For more information call 1-800-468-1502 or visit our website at customer.honeywell.com.
Dimensions and Clearances
SIDE VIEW
11-1/2 (295)
FRONT VIEW
29-1/2 (749)
22-1/2
(572)
POWER
CONNECTION
TOP VIEW
5-9/32
(134)
Fig. 1. Dimensions in in. (mm) and clearances.
6
(205)
M32361
The Honeywell Ventilation System provides improved indoor air quality through its high performance and efficiency.
Features
• 2 operating modes (Intermittent and Continuous Ventilation)
• Variable speed
• Compact installation
• Sloped drain pan
• Backward inclined motor blades
• Permanent lubrication of PSC motors
• Door opens downward
• No obstruction around the drain pan
• Simple electronic control
• Easy access to the control connection box
• Detachable 6 inch (dia.) collar system
• Proportional defrost
• Speed control balancing system
• Simplified mounting system
• Washable ERV core
• 10-year limited warranty on ventilation motors
• 5-year warranty
68-3078EF-01
Removable Duct Collars
Spend less time on the ladder by easily connecting the ductwork to the collars away from the unit before it’s hung, and then sliding the collars back into place once ducted.
Intuitive Balancing
Two variable-speed motors — one for each air stream — work with the integrated speed control so installers can adjust the speed of each motor up and down to easily balance the system. This eliminates the need for adjusting dampers.
Adjustable Hanging Straps
Just like tightening or loosening straps on a backpack, these straps make it easy to raise, lower and level the unit into place
Ventilation Performance VNT5150E
External Static Pressure
Pa
25 in w.c.
0.1
50
75
100
0.2
0.3
0.4
125
150
175
200
225
250
0.5
0.6
0.7
0.8
0.9
1.0
10 20 30 40
VNT5150E1000
70
1.2
0
1
0.8
EXTERNAL
STATIC
PRESSURE
(IN. W. C)
0.6
0.4
0.2
0
0
NET SUPPLY AIR FLOW
50 100
AIR FLOW (CFM)
150
48
41
38
69
62
55
Net Supply Air Flow
L/s
92
CFM
197
87
82
75
185
173
160
146
132
116
102
88
81
80 90
200
100 110
300
275
250
225
200
250
0
50
25
175
150
125
EXTERNAL
STATIC
PRESSURE
(PA)
100
75
M32362
Push Through—Operation System
Outside air is pushed through the heat exchanger, which acts as a noise reducer. This process is very silent and provides you with better home comfort.
FRESH AIR
FROM
OUTSIDE
EXHAUST
AIR TO
OUTSIDE
EXHAUST
AIR FROM
HOME
FRESH AIR
FROM
OUTSIDE
M32359
Proportional Defrost—Operation System
The defrost energy is controlled by the outdoor air temperature. The motor speed essentially increases as outdoor temperature drops to provide increased defrost capability.
WARNING: Installation must be performed by a qualified service technician and must comply with local codes. Remove power to the device before installing or servicing the device. Failure to connect the device according to these instructions may result in damage to the device or the controls.
Energy Performance VNT5150E
Supply Temperature Net Supply Air Flow Average Power Sensible Recovery Apparent Sensible
°C °F L/s CFM Watts Efficiency (%) Effectiveness (%)
0
0
0
-15
35
32
32
32
5
95
30
45
55
30
30
64
96
117
64
64
75
100
126
80
75
52
44
40
52
49
67
64
62
67
Total Recovery Efficiency = 49%
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9 http://customer.honeywell.com
® U.S. Registered Trademark.
© 2010 Honeywell International Inc.
68-3078EF—01 M.S. 12-10
Printed in U.S.A.
advertisement