Honeywell VNT5150E1000 159 CFM TrueFRESH Energy Recovery Ventilation System - For Homes Up to 3,150 Sq Ft Spec Sheet

Add to My manuals
2 Pages

advertisement

Honeywell VNT5150E1000 159 CFM TrueFRESH Energy Recovery Ventilation System - For Homes Up to 3,150 Sq Ft Spec Sheet | Manualzz

VNT5150E1000

Ventilation System

SPECIFICATION DATA

VNT5150E Capacities and Performance

Part Number: VNT5150E1000

Product Weight: 42 lbs (19 Kg)

Input Voltage:

Input Current:

120 VAC; 60 Hz.

1.5 A

Output Power to Terminals

Operating Ranges:

Temp:

Humidity:

CFM:

Type of Heat

Exchanger:

5 VDC, 1.0 A

34–135 ºF (1.1–57.2 ºC)

0-99% RH

30–160

Cross-flow (Enthalpic)

Exchange Surface: 85 sq. ft.

Energy Core Dimensions:

Width: 10 in. (381 mm)

Height:

Length:

12 in. (305 mm)

12 in. (305 mm)

Filter Dimensions:

Height:

Width:

12 in. (305 mm)

10 in. (254 mm)

Shipping Specs:

Length:

Height:

Width:

Weight:

27.5 in. (698 mm)

13.4 in. (340 mm)

25.8 in. (656 mm)

47.5 lbs (21.55 Kg)

Defrost Type:

Drain Tubing

Diameter

Evacuation

1/2 in. (12.7 mm)

Flexible Duct (2):

6 in. round for inlet and outlet. Flexible vinyl, compatible for connection to rigid or flexible ducting with sheet metal screws and/or tape.

Cabinet:

20 gauge galvanized steel powder-coat painted.

Certification:

QPS, SGSUSTC, ARI 1060

Conforms to UL Std. 1812.

Install the unit according to National Electric

Codes.

For more information call 1-800-468-1502 or visit our website at customer.honeywell.com.

Dimensions and Clearances

SIDE VIEW

11-1/2 (295)

FRONT VIEW

29-1/2 (749)

22-1/2

(572)

POWER

CONNECTION

TOP VIEW

5-9/32

(134)

Fig. 1. Dimensions in in. (mm) and clearances.

6

(205)

M32361

The Honeywell Ventilation System provides improved indoor air quality through its high performance and efficiency.

Features

• 2 operating modes (Intermittent and Continuous Ventilation)

• Variable speed

• Compact installation

• Sloped drain pan

• Backward inclined motor blades

• Permanent lubrication of PSC motors

• Door opens downward

• No obstruction around the drain pan

• Simple electronic control

• Easy access to the control connection box

• Detachable 6 inch (dia.) collar system

• Proportional defrost

• Speed control balancing system

• Simplified mounting system

• Washable ERV core

• 10-year limited warranty on ventilation motors

• 5-year warranty

68-3078EF-01

Removable Duct Collars

Spend less time on the ladder by easily connecting the ductwork to the collars away from the unit before it’s hung, and then sliding the collars back into place once ducted.

Intuitive Balancing

Two variable-speed motors — one for each air stream — work with the integrated speed control so installers can adjust the speed of each motor up and down to easily balance the system. This eliminates the need for adjusting dampers.

Adjustable Hanging Straps

Just like tightening or loosening straps on a backpack, these straps make it easy to raise, lower and level the unit into place

Ventilation Performance VNT5150E

External Static Pressure

Pa

25 in w.c.

0.1

50

75

100

0.2

0.3

0.4

125

150

175

200

225

250

0.5

0.6

0.7

0.8

0.9

1.0

10 20 30 40

VNT5150E1000

70

1.2

0

1

0.8

EXTERNAL

STATIC

PRESSURE

(IN. W. C)

0.6

0.4

0.2

0

0

NET SUPPLY AIR FLOW

50 100

AIR FLOW (CFM)

150

48

41

38

69

62

55

Net Supply Air Flow

L/s

92

CFM

197

87

82

75

185

173

160

146

132

116

102

88

81

80 90

200

100 110

300

275

250

225

200

250

0

50

25

175

150

125

EXTERNAL

STATIC

PRESSURE

(PA)

100

75

M32362

Push Through—Operation System

Outside air is pushed through the heat exchanger, which acts as a noise reducer. This process is very silent and provides you with better home comfort.

FRESH AIR

FROM

OUTSIDE

EXHAUST

AIR TO

OUTSIDE

EXHAUST

AIR FROM

HOME

FRESH AIR

FROM

OUTSIDE

M32359

Proportional Defrost—Operation System

The defrost energy is controlled by the outdoor air temperature. The motor speed essentially increases as outdoor temperature drops to provide increased defrost capability.

WARNING: Installation must be performed by a qualified service technician and must comply with local codes. Remove power to the device before installing or servicing the device. Failure to connect the device according to these instructions may result in damage to the device or the controls.

Energy Performance VNT5150E

Supply Temperature Net Supply Air Flow Average Power Sensible Recovery Apparent Sensible

°C °F L/s CFM Watts Efficiency (%) Effectiveness (%)

0

0

0

-15

35

32

32

32

5

95

30

45

55

30

30

64

96

117

64

64

75

100

126

80

75

52

44

40

52

49

67

64

62

67

Total Recovery Efficiency = 49%

Automation and Control Solutions

Honeywell International Inc.

1985 Douglas Drive North

Golden Valley, MN 55422

Honeywell Limited-Honeywell Limitée

35 Dynamic Drive

Toronto, Ontario M1V 4Z9 http://customer.honeywell.com

® U.S. Registered Trademark.

© 2010 Honeywell International Inc.

68-3078EF—01 M.S. 12-10

Printed in U.S.A.

advertisement

Related manuals

Download PDF

advertisement