Реклама
Реклама
64 MODEL 164 30 MHz Sweep Generator * 30 uHz to 30 MHz Frequency Range * Variable Rise and Fall Times 30 uHz to 30 MHz Frequency Range Model 164 provides an extremely wide frequency range for both high and low frequency applications, 30 uHz to 30 MHz. This broad range will cover many of your generator applications. Model 164 is a function generator with full trigger and gate capability as well as a sweep generator with internal sweep and step sweep. Variable Rise and Fall Time For pulse applications, Model 164 provides positive, negative and balancedpulse outputs. Duty cycle, rise and fall times and dc offset ® Trapezoidal Waveforms FUNCTION GENERATORS e Trigger and Gated Operation e Sweep Up or Down levels of these outputs are all inde- pendently variable. Trigger and Gated Operation Single cycles or ‘’bursts’’ of cycles of the selected waveform can be pro- duced by triggering the generator with an external signal or with the manual front panel switch. Trigger start/stop point can be adjusted to give haversine outputs as well as complex waveforms. Sweep Up or Down Besides the conventional low-to-high frequency sweep, Model 164 will sweep high-to-low. Sweep width is / X чей A FREG IKri GER MODE SWEEP/STEP TIME FR. LEVE IACIARIT i joe = HY) 1s \ 105 No 7 A % не ыы 300 д AT . dd aE Ms fully adjustable to 1000:1 and sweep time is continuously adjustable from 10 microseconds to 100 seconds. Sweep hold mode stops the genera- tor atthe sweep limit so that you can easily and accurately adjust the total sweep width. Incremental Frequency Steps Step sweep is another sweep mode onthe Model 164. The sweep width Is divided into 10 steps, giving 11 fre- quencies. You can step sweep through 11 frequency steps automa- tically or make one step with each press of the manual trigger switch. Steps can be up or down in frequency. WAVEFORM ОНТРОТ АТТЕМ 146) TRIG START STOP DE OFFSET E NEAR E B'CAL VAR OFF 65 MODEL 164 FUNCTION GENERATORS VERSATILITY 80 dB. High level O to — 50 dB and low Time Symmetry Waveforms level — 40 to — 80 dB outputs. + 0.5% for 30 Hz to 300 kHz. Sine V , square "|; , triangle vV , positive square n , negative square ur, trapezoid V , positive trapezoid no, negative trapezoid v ,ramp 37 \ and stair step (up and down) —. Operational Modes Continuous: Main generator oscillates continuously at selected frequency. Triggered: Generator quiescent until triggered by an external signal, then generates one cycle at selected frequency. Gated: As triggered mode, except main generator oscillates for the dura- tion of the external signal. Last cycle started is completed. Continuous Sweep: Recurring low-to- high or high-to-low frequency oscilla- tions. Range and rate selectable. Triggered Sweep: Low-to-high or high- to-low frequency oscillation with each trigger input; then returns to initial fre- quency after sweep. Sweep Hold: Sweep from start fre- quency to stop frequency and con- tinued oscillation at stop frequency. Sweep Burst: Main generator quies- cent until gated, then in sweep hold mode for duration of gate; return to quiescent state when gate signal is removed. Single Step: Main generator steps to next frequency with each trigger in stair sequence. After 10th step, returns to initial frequency. GEN MODE SWP CONT BURST SWP TRIG GATED / WP N \ 17 SWP ‚ FT TRIG—. HOLD == SINGLE CONT STEP Mode Control Frequency Range 0.00003 Hz to 30 MHz in 11 decade ranges with dial and frequency vernier. Main Output Ny y Ny, TL and \; selectable and variable to 20 Vp-p (10 Vp-p into 509). A, A andv to 10V peak (5V peak into 502). DC voltage adjustable to + 10V, 502 source. Output peak current is 100 MA minimum for all waveforms and de. O to 60 dB attenua- tion in 10 dB steps with a 20 dB ver- nier; maximum overall attenuation DC Output and DC Offset Waveform offser and dc output selec- table through 50% outputs. Adjustable between + 10V (+ 5V into 509). DC offset and output waveform are attenuated proportionately by the attenuator. Sync Output Approximately O to + 4V into open cir- cuit; 509 source. Rise and fall times typically 10 ns into 5092. Sync waveform normally square is rec- tangular with SYMMETRY control on. Sweep Sweep/Step Time: 10 us to 100s in 7 ranges selectable. Sweep Output Sweep Signal: 0 to + 5V ramp or stair step. Source Impedance: 60092. GCV—Generator Control Voltage 0 to + 5V output proportional to main generator frequency Source Impedance: 600%. VCG—Voltage Controlled Generator Up to 1000:1 frequency change with external O to + 5V signal. Upper fre- quency is limited to maximum of selected range. Input Impedance: 5 kQ. Slew Rate: 2% of range per us. Linearity: + 0.5% for 0.0003 Hz to 3 MHz. Symmetry Control Symmetry of all waveform outputs is continuously adjustable from 1:19 to 19:1. Varying symmetry provides variable duty cycle pulses, sawtooth or nonsymmetrical trapezoidal wave- forms. NOTE: When SYMMETRY control is used, indicated frequency is divided by approxi- ately 10. Slope and Width Control For trapezoidal waveforms \, , A and v only. Ratio of period to rise or fall time is variable from 2:1 (triangle) to greater than 100:1 with 12 ns minimum rise and fall time. Trigger and Gate Input Range: 1V p-p to + 50V. Impedance: 10 k, 33 pF. Pulse Width: 25 ns min. Repetition Rate: 20 MHz max. Adjustable Triggered Signal Start/ Stop Point Approximately: — 90° to + 90° to 3 MHz. — 90° to 0° for 3 to 30 MHz. FREQUENCY PRECISION Dial Accuracy +(1% of setting + 1% of full scale) or 0.0003 Hz to 300 kHz. + (3% of setting + 2% of full scale) for 300 kHz to 30 MHz. + 1.0% for 0.0003 to 30 Hz. AMPLITUDE PRECISION Amplitude Change With Frequency Sine variation less than: + 0.1 dB to 300 kHz. +0.2 dB to 3 MHz. + 2.5 dB to 30 MHz. Amplitude Symmetry 1% of amplitude range to 3 MHz. Step Attenuator Accuracy + 0.25 dB per 10 dB step. WAVEFORM CHARACTERISTIC Sine Distortion (Continuous Mode) <0.5% for 10 Hz to 100 kHz. <1.0% for 0.0003 Hz to 300 kHz. All harmonics at least 26 dB down to 30 MHz. Triangle Linearity Greater than 99% for 0.0003 to 300 kHz. Square Wave Rise and Fall Time Less than 12 ns terminated into 509 load. Total Aberrations Less than 5%. GENERAL Stability Amplitude, dc offset and frequency. Short Term: + 0.05% for 10 minutes. Long Term: + 0.25% for 24 hours. Environment Specifications apply at 23° +5°C. Instrument will operate from 0° to + 55°C. Dimensions 36.8 cm (14% in) wide; 13.3 cm (5% in.) high; 34.3 em (13% in.) deep. Weight 6.8 kg (14.9 Ib) net; 8.6 kg (19 Ib) shipping. Power 90 to 110V, 105 to 125V, 180 to 220V or 210 to 250V; 50 to 400 Hz: less than 50 VA. NOTE: Specifications apply from 10 to 100% of a selected frequency range with SYM- METRY control at OFF. Symmetry and vernier affect frequency calibration. Maximum possi- ble asymmetry is a function of frequency setting. FACTORY/FOB San Diego, CA ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща с прости думи, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или сложни документи.
Реклама