Annonce
Annonce
18 MODEL 144 FUNCTION GENERATORS 10 MHz Sweep Generator Two Independent Generators The Model 144 gives you two independent generators, the main function generator and an auxiliary ramp generator. The auxiliary gen- erator can sweep, trigger and gate the main generator with controllable sweep time and trigger and gate repetition rates. 1000:1 Internal Sweep Capability This dual generator instrument features frequency sweep with ad- justable sweep limits. Maximum sweep ratio is 1000:1 on any range. You can easily adjust the sweep rate via a convenient front panel control, from one sweep every one hundred seconds to one sweep in one micro- second. An external signal may also be used to sweep the main generator. Six Different Operational Modes This versatile instrument has six operational modes: continuous, triggered, gated, continuous sweep, triggered sweep and sweep-and-hold. The waveform capability of this generator meets a broad range of laboratory signal requirements. MODE CONT SWP GATED TRIG cont 7 — + Internal or External Sweep Capability Two Independent Generators Six Different Operational Modes Frequency From 0.0005 Hz to 10 MHz Sweep or Generator Control Voltage (GCV) Output The versatile SWP/GCV output gives you the maximum utility in sweep function generator operation. When the generator is being used in one of the three internal sweep modes, the output is a voltage proportional to frequency, ideally suited as a horizontal or X-axis drive for oscillo- scopes or recorders. When the generator is in the other modes, the output is a fixed 5 volt sawtooth, which can be used to trigger or tone burst the main generator. MODEL 144 HF SWEEP GENERATOR OUTPUT ATTEN (dB) SWEEP —30 18 У 7 SWP/GCV OUT 19 MODEL 144 VERSATILITY Waveforms Sine V, square'l, triangle”, positive pulse rt, negative pulse ur and ramp 1. Operational Modes Continuous: Generator oscillates continuously at selected frequency. Triggered: Generator quiescent until triggered by an external signal, then generates one cycle at selected frequency. Gated: As triggered mode, except generator oscillates for the duration of the external signal. Continuous Sweep: Recurring low- to-hign frequency oscillation. Range and rate selectable. Triggered Sweep: Low-to-high fre- guency oscillation with each trigger input; then return to low frequency after sweep. Sweep-and-Hold: Sweep-to-high fre- quency oscillation. Frequency Range + 0.0005 Hz to 10 MHz in 10 overlapping decade ranges with dial and frequen- Cy vernier. Main Output NT A selectable and variable to 30V p-p (15V p-p into 5092). n and ır selectable and variable to + 15V peak (7.5V peak into 502). Pre- cision output attenuator calibrated in 10 dB steps to 60 dB with 20 dB ver- nier for overall attenuation of 80 dB. Output impedance 50€2 . DC Offset Manual rear panel control. Waveform offset at 5082 output between + 10 Vdc (+5 Vdc into 50 2 ) with peak signal and offset amplitude limited to + 15 Vdc into open circuit (x= 7.5 Vdc into 50 £2). DC offset and output waveform attenuated proportionately by 60 dB output attenuator. Sync Output Greater than 4V p-p (2V p-p into 5092). Rise and fall time less than 20 ns. Square waveform for symmetrical 509 outputs; rectangular waveform for pulse and ramp 50§2 outputs. Sync pulse polarity opposite that of 50§2 output square wave. Sweep Sweep Time: 10 us to 100s. Sweep Width: Up to 1000:1. SWP/GCV Output Ramp A output (0 to +5V fixed) when in continuous, triggered or gated mode. GCV output (0 to +5V maxi- mum) proportional to frequency control settings when in continuous sweep, triggered sweep or sweep-and-hold mode. VCG — Voltage Controlled Generator Up to 1000:1 frequency change with external 0 to +5V signal. Upper fre- quency is limited to maximum of selected range. Slew Rate: 2% of range per us. Input Impedance: 5 kS2. Linearity + 0.2% for 10 Hz to 100 kHz. + 0.5% for 0.001 Hz to 1 MHz. Symmetry Control Symmetry of all waveform outputs is continuously adjustable from 1:19 to 19:1. Varying symmetry provides var- lable duty cycle pulses, sawtooth ramps and nonsymmetrical sine waves. NOTE: When SYMMETRY control is used, indi- cated frequency is divided by approximately 10, Trigger and Gate Input: 1V peak to peak min. Impedance: 10 k§2. Tone Burst Using Sweep Signal as Trigger FREQUENCY PRECISION Dial Accuracy + (1% of setting + 1% of full scale) for 0.01 Hz to 1 MHz. + (2% of setting + 2% of full scale) for 1 to 10 MHz. Time Symmetry + 0.5% for 10 Hz to 100 kHz. + 1.0% for 0.01 Hz to 500 kHz. FUNCTION GENERATORS AMPLITUDE PRECISION Amplitude Change With Frequency Sine variation less than: 0.1 dB to 100 kHz. 0.2 dB to 1 MHz. 2.0 dB to 10 MHZ. Amplitude Symmetry All waveforms (except pulse) sym- metrical within + 1%. Step Attenuator Accuracy + 0.25 dB per 10 dB step. WAVEFORM CHARACTERISTICS Sine Distortion (Continuous Mode) Less than: 0.5% for 10 Hz to 100 kHz. 1.0% for 100 kHz to 10 MHz. All harmonics at least 30 dB down for 110 10 MHz. Triangle Linearity Greater than 99% for 0.0005 Hz to 100 kHz. Square Wave Rise and Fall Time Less than 20 ns terminated into 5082 load (limited to 500 V/ us). Total Aberrations Less than 5%. GENERAL Stability Amplitude, frequency and dc offset. Short Term: + 0.05% for 10 minutes. Long Term: +0.25% for 24 hours. Environmental Specifications apply at 25°C +5°C. Instrument will operate from 0°C to + 50°C. Dimensions 21.6 ст (8% in.) wide: 13.3 cm (5% in.) high; 29.2 cm (11% in.) deep). Weight 4.1 kg (9 Ib) net; 5.9 kg (13 Ib) shipping. Power 105 to 125V or 200 to 250V; 50 to 400 Hz; less than 40 watts, NOTE: Specifications apply for frequencies obtained when dial is between 1 and 10 with SYMMETRY control to NORM. Symmetry and vernier affect frequency calibration. PRICE (FOB San Diego) Model 144 $995 ">
/
Download
Bare en venlig påmindelse. Du kan se dokumentet lige her. Men vigtigst af alt har vores AI allerede læst det. Den kan forklare komplekse ting i enkle vendinger, besvare dine spørgsmål på ethvert sprog og hjælpe dig med hurtigt at navigere selv de længste eller mest komplicerede dokumenter.
Annonce