Intel SERVER CHASSIS SR2500 Datasheet
Advertisement
Advertisement
Intel
®
Server Chassis SR2500
Intel
®
Server System SR2500AL
Technical Product Specification
Intel order number D31980-004
Revision – 1.00
June 2006
Enterprise Platforms and Services Division - Marketing
Revision History
Date
June 2006
Intel® Server System SR2500AL
Revision History
Modifications Revision
Number
1.00 Initial external release. ii
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Disclaimers
Disclaimers
Information in this document is provided in connection with Intel
®
products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked
"reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The Intel® Server System SR2500AL may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.
This document and the software described in it is furnished under license and may only be used or copied in accordance with the terms of the license. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be provided in association with this document.
Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation.
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © Intel Corporation 2006.
Revision – 1.00
Intel order number D31980-004 iii
Table of Contents
Table of Contents
Intel® Server System SR2500AL
1.
Product Overview ................................................................................................................. 1
1.1
Chassis Views ......................................................................................................... 1
1.2
1.3
Chassis Dimensions ................................................................................................ 2
System Components ............................................................................................... 2
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
System Boards ........................................................................................................ 3
Control Panel Options.............................................................................................. 5
Hard Drive and Peripheral Bays .............................................................................. 7
Power Sub-system................................................................................................... 8
System Cooling........................................................................................................ 8
Chassis Security ...................................................................................................... 8
Rack and Cabinet Mounting Options ....................................................................... 9
Front Bezel Features ............................................................................................... 9
2.
Power Sub-System ............................................................................................................. 11
2.1
2.2
Mechanical Overview............................................................................................. 11
Single Power Supply Module Population ............................................................... 12
2.3
2.4
2.5
2.6
Handle and Retention Mechanism......................................................................... 12
Hot-swap Support .................................................................................................. 12
Airflow .................................................................................................................... 13
AC Power Cord Specification Requirements ......................................................... 13
2.7
Output Cable Harness ........................................................................................... 13
2.7.1
P1 – Server Board Power Connector .................................................................... 14
2.7.2
P2 – Processor Power Connector ......................................................................... 14
2.7.3
P3 – Power Signal Connector................................................................................ 15
2.7.4
P4 – Backplane Power Connector ......................................................................... 15
2.7.5
P5 Mid-plane Power Connector ............................................................................. 15
2.8
AC Input Requirements ......................................................................................... 15
2.8.1
Efficiency ............................................................................................................... 16
2.8.2
AC Input Voltage Specification .............................................................................. 16
2.8.3
AC Line Dropout / Holdup ...................................................................................... 16
2.8.4
AC Line 5 VSB Holdup .......................................................................................... 16
2.8.5
AC Inrush............................................................................................................... 17
2.9
Protection Circuits.................................................................................................. 17
2.9.1
Over-Current Protection (OCP).............................................................................. 17
2.9.2
Over-Voltage Protection (OVP) ............................................................................. 17
2.9.3
Over-Temperature Protection (OTP) ..................................................................... 18 iv
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
2.10
Table of Contents
DC Output Specification ........................................................................................ 18
2.10.1
Output Power / Currents ........................................................................................ 18
2.10.2
Standby Output / Standby Mode............................................................................ 18
2.11
Power Supply Status LED ..................................................................................... 19
3.
Cooling Subsystem ............................................................................................................ 20
3.1
3.2
Non-redundant Fan Module ................................................................................... 21
Redundant System Fan Module ............................................................................ 23
3.3
Air Flow Support .................................................................................................... 25
3.3.1
Power Supply Zone ............................................................................................... 25
3.3.2
Full Height Riser Zone ........................................................................................... 25
3.3.3
CPU / Memory / Low Profile PCI Zone .................................................................. 26
3.4
Drive Bay Population ............................................................................................. 26
4.
System Board Interconnects............................................................................................. 27
4.1
Mid-plane ............................................................................................................... 27
4.2
4.3
Bridge Board.......................................................................................................... 34
Hot-Swap SATA/SAS Backplane........................................................................... 34
5.
Peripheral and Hard Drive Sub-System............................................................................ 42
5.1
Slimline Drive Bay.................................................................................................. 42
5.2
Hard Drive Bays..................................................................................................... 44
5.2.1
Hot-swap Drive Trays ............................................................................................ 44
5.3
Optional Tape Drive or 6 th
Hard Drive Flex Bay..................................................... 45
5.4
Mid-plane Options.................................................................................................. 46
5.4.1
Passive Mid-plane ................................................................................................. 46
5.4.2
Active Mid-plane with Intel
®
SAS /SAS RAID Support ........................................... 47
5.5
Hot-Swap SAS/SATA Backplane........................................................................... 50
5.5.1
SAS/SATA Backplane Layout................................................................................ 51
5.5.2
SAS/SATA Backplane Functional Architecture...................................................... 53
6.
Standard Control Panel ..................................................................................................... 56
6.1
6.2
Control Panel Buttons........................................................................................... 56
Control Panel LED Indicators ................................................................................ 57
6.2.1
Power / Sleep LED ................................................................................................ 59
6.2.2
System Status LED................................................................................................ 59
6.2.3
Drive Activity LED .................................................................................................. 60
6.2.4
System Identification LED...................................................................................... 60
6.3
Control Panel Connectors...................................................................................... 61
6.4
Internal Control Panel Interconnect ....................................................................... 62
7.
Intel
®
Local Control Panel.................................................................................................. 64
7.1
LED Functionality................................................................................................... 65
Revision – 1.00
Intel order number D31980-004 v
Table of Contents Intel® Server System SR2500AL
7.1.1
Power / Sleep LED ................................................................................................ 66
7.1.2
System Status LED................................................................................................ 66
7.1.3
Drive Activity LED .................................................................................................. 67
7.1.4
System Identification LED...................................................................................... 67
7.2
Intel
®
Local Control Panel Interconnects ............................................................... 68
8.
PCI Riser Cards and Assembly ......................................................................................... 70
8.1
Riser Card Options ................................................................................................ 71
8.2
9.1
PCI Riser Card Mechanical Drawings ................................................................... 72
9.
Supported Intel
®
Server Boards........................................................................................ 76
Intel
®
Server Board S5000PAL / S5000XAL Feature Set ...................................... 76
9.1.1
Processor Support ................................................................................................. 78
10.
Environmental and Regulatory Specifications ............................................................... 81
10.1
10.2
System Level Environmental Limits ....................................................................... 81
Product Regulatory Compliance ............................................................................ 81
10.2.1
Product Safety Compliance ................................................................................... 81
10.2.2
Product EMC Compliance ..................................................................................... 82
10.2.3
Product Regulatory Compliance Markings ............................................................ 83
10.3
Electromagnetic Compatibility Notices .................................................................. 84
10.3.1
USA ....................................................................................................................... 84
10.3.2
FCC Verification Statement ................................................................................... 85
10.3.3
ICES-003 (Canada) ............................................................................................... 85
10.3.4
Europe (CE Declaration of Conformity) ................................................................. 85
10.3.5
Japan EMC Compatibility ...................................................................................... 85
10.3.6
BSMI (Taiwan) ....................................................................................................... 86
10.3.7
Korean RRL Compliance ....................................................................................... 86
10.3.8
CNCA (CCC-China) ............................................................................................... 86
10.4
10.5
10.6
10.7
Replacing the Back up Battery .............................................................................. 87
Serviceability and Availability................................................................................. 88
Restriction of Hazardous Substances (RoHS) Compliance................................... 88
Regulated Specified Components ......................................................................... 89
11.
Platform Control ................................................................................................................. 90
11.1
Overview ................................................................................................................ 90
11.2
FBDIMM Open Loop Throughput Throttling .......................................................... 91
11.3
Fan Speed Control................................................................................................. 91
11.3.1
System Configuration Using the FRUSDR Utility................................................... 92
11.3.2
Fan Speed Control from BMC and BIOS Inputs .................................................... 92
Appendix A: Chassis Integration and Usage Tips ................................................................. 96
Appendix B: POST Code Diagnostic LED Decoder ............................................................... 97 vi
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Table of Contents
Appendix C: POST Error Beep Codes................................................................................... 101
Glossary................................................................................................................................... 102
Reference Documents ............................................................................................................ 103
Revision – 1.00
Intel order number D31980-004 vii
List of Figures
List of Figures
Intel® Server System SR2500AL
Figure 1. Front View with Optional Bezel...................................................................................... 1
Figure 2. Front View without Bezel (Shown with Standard Control Panel Option) ....................... 1
Figure 3. Back View – (Shown with 1+1 Power Supply Configuration)......................................... 1
Figure 4. Major Chassis Components........................................................................................... 2
Figure 5. Back Panel Feature Overview ....................................................................................... 3
Figure 6. Control Panel Modules .................................................................................................. 5
Figure 7. Standard Control Panel Overview ................................................................................. 5
Figure 8. LCD Control Panel Overview ......................................................................................... 6
Figure 9. Front Panel Feature Overview ....................................................................................... 7
Figure 10. Optional Front Bezel .................................................................................................... 9
Figure 11. Front Bezel Supporting Standard Control Panel.......................................................... 9
Figure 12. Front Bezel Supporting Intel
®
Local Control Panel .................................................... 10
Figure 13. Mechanical Drawing for Dual (1+1 configuration) Power Supply Enclosure with PDM11
Figure 14. Power Supply Blank................................................................................................... 12
Figure 15. Non-Redundant Fan Module ..................................................................................... 21
Figure 16. Non-Redundant Fan Header Assignments on Mid-plane .......................................... 22
Figure 17. Fan Module Assembly ............................................................................................... 23
Figure 18. Redudant Fan Header Assignments on Mid-plane .................................................... 24
Figure 19. CPU Air Duct with Air Baffle ...................................................................................... 26
Figure 20. Drive Blank ................................................................................................................ 26
Figure 21. Passive Mid-plane Board........................................................................................... 27
Figure 22. SAS/SAS RAID Mid-plane Board .............................................................................. 28
Figure 23. Bridge Board.............................................................................................................. 34
Figure 24. Hot-Swap SAS/SATA Backplane (Front Side View) .................................................. 35
Figure 25. Hot-Swap SAS/SATA Backplane (Back Side View) .................................................. 35
Figure 26. Optional 6 th
Hard Drive (Front View).......................................................................... 42
Figure 27. Slim-Line Optical Drive Assembly.............................................................................. 42
Figure 28. 50-pin Connector to Slimline Optical Device ............................................................. 43
Figure 29. Hard Drive Tray Assembly ......................................................................................... 44
Figure 30. Optional 6 th
Hard Drive (Front View).......................................................................... 45
Figure 31. Optional Tape Drive (Front View) .............................................................................. 45
Figure 32. Passive Mid-plane Board........................................................................................... 46
Figure 33. Active Mid-plane with SAS / SAS RAID Support ....................................................... 47
Figure 34. Architecture Overview................................................................................................ 48
Figure 35. Hot-swap SAS/SATA Backplane (Front Side View) .................................................. 51 viii
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL List of Figures
Figure 36. Hot-swap SAS/SATA Backplane (Back Side View) ................................................... 52
Figure 37. SAS/SATA Backplane Functional Block Diagram ..................................................... 53
Figure 38. Standard Control Panel Assembly Module ................................................................ 56
Figure 39. Control Panel Buttons................................................................................................ 56
Figure 40. Control Panel LEDs ................................................................................................... 57
Figure 41. Standard Control Panel PCB ..................................................................................... 62
Figure 42. Intel
®
Local Control Panel Assembly Module............................................................. 64
Figure 43. Intel
®
Local Control Panel Overview .......................................................................... 64
Figure 44. Low Profile PCIe* Riser ............................................................................................. 70
Figure 45. Low Profile Passive PCI Express* Riser Card ........................................................... 72
Figure 46. Full Height PCI Express* Riser Card ......................................................................... 73
Figure 47. Full Height Passive PCI-X* Riser Card ...................................................................... 74
Figure 48. Full Height Active PCI-X* Riser Card......................................................................... 75
Figure 49. Intel
®
Server Board S5000PAL .................................................................................. 77
Figure 50. Intel
®
Server Board S5000PAL Components............................................................. 78
Figure 51. CEK Processor Mounting .......................................................................................... 80
Figure 52. Diagnostic LED Placement Diagram ......................................................................... 97
Revision – 1.00
Intel order number D31980-004 ix
List of Tables
List of Tables
Intel® Server System SR2500AL
Table 1. Chassis Dimensions ....................................................................................................... 2
Table 2. Power Harness Cable Definitions ................................................................................. 13
Table 3. P1 Main Power Connector ............................................................................................ 14
Table 4. P2 Processor Power Connector.................................................................................... 14
Table 5. P3 Power Signal Connector.......................................................................................... 15
Table 6. P4 Hot Swap Backplane Power Connector .................................................................. 15
Table 7. P5 Mid-plane Power Connector ................................................................................... 15
Table 8. Efficiency...................................................................................................................... 16
Table 9. AC Input Rating............................................................................................................. 16
Table 10. Over-Current Protection Limits / 240VA Protection .................................................... 17
Table 11. Over-Voltage Protection (OVP) Limits ........................................................................ 17
Table 12. LED Indicators ............................................................................................................ 19
Table 13 Nonredundant Cooling Zones ..................................................................................... 21
Table 14. Non-redundant Fan Connector Pin Assingment ........................................................ 22
Table 15. Nonredundant Fan Header Assignment .................................................................... 23
Table 16 Redundant Cooling Zones .......................................................................................... 23
Table 17 Redundant Fan Connector Pin Assingment................................................................ 24
Table 18 Redundant Fan Header Assignment........................................................................... 25
Table 19. 120-pin Server Board-to-Mid-plane Bridge Board Connector Pin-out......................... 28
Table 20. Mid-plane Fan Header Pin-outs .................................................................................. 30
Table 21. Mid-plane Power Connector Pin-out ........................................................................... 30
Table 22. Mid-plane-to-Backplane Card Edge Connector #1 Pin-out ......................................... 31
Table 23. Mid-plane-to-Backplane Card Edge Connector #2 Pin-out ......................................... 32
Table 24. Active Mid-plane SAS RAID Battery Backup Connector Pin-out ................................ 33
Table 25. Passive Mid-plane SATA/SAS Connector Pin-outs .................................................... 33
Table 26. 2x4 SAS/SATA Backplane Power Connector Pin-out (J7L2) ..................................... 36
Table 27. 1x7 6th HDD / Tape Drive Option Power Connector Pin-out (J2M1) .......................... 36
Table 28. 6th HDD Option SATA/SAS I/O Connector Pin-out (J4L1) ......................................... 36
Table 29. 2x22 Slim-Line IDE Optical Drive Connector Pin-out (J5N1) ...................................... 36
Table 30. Slim-Line Optical Drive Slot Connector (J1A1) ........................................................... 37
Table 31. IDE Device Master/Slave Configuration Jumper (J6L1) ............................................. 37
Table 32. I2C Connector (J6L3).................................................................................................. 37
Table 33. PCIe X4 Slot Connector from Mid-plane (J4N1) ......................................................... 38
Table 34. PCIe X4 Slot Connector from Mid-plane (J6N1) ......................................................... 39
Table 35. USB Floppy Drive Connector (J2A1) .......................................................................... 39 x
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL List of Tables
Table 36. Intel
®
Local Control Panel (LCP) Connector (J9A1)................................................... 40
Table 37. Control Panel Slot Connector (J9B1).......................................................................... 40
Table 38. SAS/SATA Hard Drive Connector Pin-outs (J2C3, J2B1, J4C1, J4B1, J7C1)............ 41
Table 39. J1L1 50-pin Connector to Slimline Optical Device...................................................... 43
Table 40. Hard Drive LED Function Definitions .......................................................................... 54
Table 41. Hard Drive Activity LED Functionality ......................................................................... 55
Table 42. Control Button and Intrusion Switch Functions ........................................................... 57
Table 43. Control Panel LED Functions...................................................................................... 58
Table 44. SSI Power LED Operation .......................................................................................... 59
Table 45. Control Panel LED Operation ..................................................................................... 59
Table 46. External USB Connectors (J1B1) ............................................................................... 61
Table 47. Video Connector (J1A1).............................................................................................. 61
Table 48. 64-pin Control Panel Connector (J6B1) ...................................................................... 63
Table 49. Control Panel LED Functions...................................................................................... 65
Table 50. SSI Power LED Operation .......................................................................................... 66
Table 51. Control Panel LED Operation ..................................................................................... 66
Table 52. 50-pin Control Panel Connector.................................................................................. 68
Table 53. Internal USB Header................................................................................................... 69
Table 54. Processor Support Matrix ........................................................................................... 79
Table 55. System Environmental Limits Summary ..................................................................... 81
Table 56: POST Progress Code LED Example .......................................................................... 97
Table 57. Diagnostic LED POST Code Decoder ........................................................................ 98
Table 58. POST Error Beep Codes .......................................................................................... 101
Table 59. BMC Beep Codes ..................................................................................................... 101
Revision – 1.00
Intel order number D31980-004 xi
List of Tables Intel® Server System SR2500AL
< This page intentionally left blank. > xii
Intel order number D31980-004
Revision – 1.00
The Intel
®
Server Chassis SR2500 is a 2U server chassis that is designed to support the Intel
®
Server Board S5000PAL. The server board and the chassis have features that are designed to support the high-density server market. This chapter provides a high-level overview of the chassis features. Greater detail for each major chassis component or feature is provided in the following chapters.
The chassis differs from previous generation products in that the majority of cables have been removed from the system and in their place are a series of board-to-board interconnects. The benefits of using board-to-board interconnects are simplification of platform integration and improved airflow for more reliable cooling.
A second significant change from the previous generation is the introduction of the mid-plane circuit board. There are two options for the mid-plane circuit board: the first option provides
SAS RAID support. The second option is a passive SATA/SAS mid-plane that can be used with either the SATA only connectors from the server board, or SATA/SAS connectors from an addin card.
Figure 1. Front View with Optional Bezel
TP02091
TP02092
Figure 2. Front View without Bezel (Shown with Standard Control Panel Option)
TP02093
Figure 3. Back View – (Shown with 1+1 Power Supply Configuration)
Revision – 1.00
Intel order number D31980-004
1
Product Overview Intel® Server System SR2500AL
Table 1. Chassis Dimensions
Width without rails
Width with rails
Depth without CMA
Depth with CMA
Max. Weight
430 mm 16.93”
451.3 mm 17.77”
704.8 mm 27.75”
838.2 mm 33.0”
29.5 kg 65 lbs
E
F
B
C
D
A
G
N
H
M
I
L
K
J
A
A. Rack Handles
B. SAS/SATA Backplane
C. Air Baffles
D. Power Distribution Module
E. Power Supply Modules
F. Riser Card Assembly
G. System Memory
Figure 4. Major Chassis Components
H. CPU Air Duct
I. System Fan Assembly
J. Standard Control Panel
K. Flex Bay – 6 th
HDD or Tape (Optional)
L. Hard Drive Bays
M. Slim-Line Optical Drive Bay
N. Front Bezel (Optional)
TP02094
2
Intel order number D31980-004
Revision – 1.00
The I/O connector locations on the back of the chassis are pre-cut, so the use of an I/O shield is not required. The supplied EMI gasket must be installed to maintain Electromagnetic
Interference (EMI) compliance levels.
A B C D
P
O
N
M
L K
J
I H G F E
TP02095
Figure 5. Back Panel Feature Overview
A. Low Profile PCIe* Add-in Card Slots
B. Full Height PCI Add-in Card Slots
C. Upper Power Supply Module
I. USB 6
J. USB 5
K. Video
D. Upper Power Receptacle
E. Lower Power Receptacle
L.
M.
DB-9 Serial A Connector
NIC 2
F. Lower Power supply Module N. NIC 1
G. Intel
®
Remote Management Module NIC (Optional) O. RJ45 Serial B Connector
H. Intel
®
I/O Expansion Module (Optional) P.
PS2* Keyboard and Mouse
Connectors
The complete system includes the use of several system boards which are used as internal interconnects and provide feature accessibility. The following provides a brief description for each.
• Bridge Board – PCB used to route signals from the server board to the mid-plane and control panel boards.
• Mid-plane – A PCB used to determine the desired hard drive interface for the system.
Two mid-plane options are available for this system: o Active SAS/SAS RAID – cable less solution with onboard SAS controller o Passive SATA – cabled to SATA ports on the server board or from add-in adapter.
• Backplane – Hot swap backplane capable of supporting both SATA and SAS hard drives.
• Riser Cards – PCI riser cards used to provide up to five add-in card slots to the system.
Available riser card options for this system include: o Low profile, two slot PCI Express* o Full height, three slot PCI-X* (passive) o Full height, three slot PCI-X (active) with onboard PXH PCI bridge chip o Full height, two PCI Express slots + one PCI-X slot
Revision – 1.00
Intel order number D31980-004
3
Product Overview Intel® Server System SR2500AL
• Optical Drive Interposer Card – Used to interface optical drive with 44-pin IDE cable as cabled from the server board.
• Control Panel – A PCB providing system status and control functionality features. Two control panel options are available for this system o Standard Control Panel o Intel
®
Local Control Panel with LCD support
• RAID Activation Keys – The system provides different RAID options depending on the mid-plane option selected. Two RAID Activation Keys are available for this system o Hardware RAID Activation Key – Used on the Active SAS/SAS RAID Mid-plane to enable hardware RAID support. o Software SATA RAID 5 Activation Key – This RAID key plugs into a connector on the server board. It is used to enable the software SATA RAID 5 functionality of the Intel
®
6321ESB I/O Controller Hub SATA ports of the server board when cabled to the passive mid-plane.
4
Intel order number D31980-004
Revision – 1.00
1.5 Control Panel Options
The chassis can support either of two control panels: a Standard Control Panel and an Intel
®
Local Control Panel with LCD support. The control panel assemblies are pre-assembled and modular in design. The entire module assembly slides into a predefined slot in the front of the chassis.
A B
TP02097
Figure 6. Control Panel Modules
The standard control panel supports several push buttons and status LEDs, along with USB and video ports to centralize system control, monitoring, and accessibility. The following diagram overviews the layout and functions of the control panel.
A B C D E F G
H
I
L K J
TP02098
Figure 7. Standard Control Panel Overview
A. NIC #2 Activity LED
B. NIC #1 Activity LED
C. Power / Sleep Button
D. Power / Sleep LED
E. Hard Drive Activity LED
F. System Status LED
G. System Identification LED
H. System Identification Button
I.
J.
System Reset Button
USB 2.0 Connector
K. Recessed NMI Button (Tool Required)
L. Video Connector
Revision – 1.00
Intel order number D31980-004
5
Product Overview Intel® Server System SR2500AL
The Intel
®
Local Control Panel utilizes a combination of control buttons, LEDs, and an LCD display to provide system accessibility, monitoring, and control functions. The following diagram provides an overview of this control panel.
A B
C
D
E
F
O N M L K J I H G
TP02099
Figure 8. LCD Control Panel Overview
A USB 2.0 Port
B LCD Display
C Menu Control Button, Scroll up
D Menu Control Button, Scroll down
E Menu Control Button, Scroll left
F Menu Control Button, Enter
I
J
K
L
Power/Sleep Button
System Status LED
NIC 2 Activity LED
NIC 1 Activity LED
M Hard Disk Drive Activity LED
N Reset Button
O USB 2.0 Port
6
Intel order number D31980-004
Revision – 1.00
1.6 Hard Drive and Peripheral Bays
The chassis is designed to support several different hard drive and peripheral configurations.
The system includes a hot swap backplane capable of supporting either SAS or SATA drives.
The sixth bay (see letter “B” in the figure below) can optionally be configured to support a sixth hard drive or 3.5” tape drive.
A B C
D
Figure 9. Front Panel Feature Overview
A. Slimline Optical Drive Bay
B. 6th HDD Drive or Tape Drive Bay (Optional)
C. System Control Panel
D. 3.5” Hard Drive Bays (5)
TP02096
Revision – 1.00
Intel order number D31980-004
7
Product Overview Intel® Server System SR2500AL
The power subsystem of the chassis consists of an integrated power distribution board and module enclosure which is capable of housing up to two 750 Watt power supply modules supporting 1+0 or redundant 1+1 power configurations. In a 1+1 redundant configuration, each power supply module is hot-swappable should one fail.
The power sub-system has several integrated management features including:
• Status LED on each power module
• Over-temperature protection circuitry
• Over-voltage protection circuitry
With the addition of server management software, the power subsystem is capable of supporting several system management features including:
• Remote Power On/Off
• FRU Information Reporting
Each power supply module operates within the following voltage ranges and ratings:
PARAMETER
Line Voltage
(110)
Line Voltage
(220)
Frequency
MIN
90V rms
RATED MAX
140V rms
Start-up
Vac
85Vac
±4Vac
180V rms
200-240 264V rms
-
Power
Off
Vac
75Vac
±5Vac
-
Max Input
AC Current
Max Rated
Input AC
Current
12 A rms
1,3
11.0A
rms
4
47 Hz 50/60Hz 63 Hz
1 Maximum input current at low input voltage range shall be measured at 90Vac, at max load.
2 Maximum input current at high input voltage range shall be measured at 180VAC, at max load.
3
This is not to be used for determining agency input current markings.
4 Maximum rated input current is measured at 100VAC and 200VAC.
2,3
5.5A
rms
4
The chassis is offered with two system cooling options. The first option is a three fan solution providing sufficient airflow to maintain internal system thermal requirements when the external ambient temperature remains within specified limits. The second option is a 5+1 fan configuration. Refer to section 3.2 for details. Should a single fan failure occur, this option provides support for hot-swap fans and fan redundancy.
In addition to the system fan options, each power supply module installed provides two additional non-redundant fans which pull air from inside the chassis out the back.
The chassis provides support for a lockable front bezel which prevents unauthorized access to the system control buttons and hard drives. In addition, a chassis intrusion switch is provided allowing server management software to monitor removal of the top cover from the chassis.
8
Intel order number D31980-004
Revision – 1.00
1.10 Rack and Cabinet Mounting Options
The chassis was designed to support 19” wide by up to 30” deep server cabinets. The chassis supports three rack mount options: o A fixed mount relay rack / cabinet mount kit (Product order code - AXXBRACKETS ) which can be configured to mount the system into either a 2-post rack or 4-post cabinet o A tool-less full extracting slide rail kit (Product order code – AXXHERAIL) designed to support an optional cable management arm (Product order code – AXXRACKCARM). o A basic slide rail kit (Product order code – AXXBASICRAIL) designed to mount the chassis into a standard (19” by up to 30” deep) EIA-310D compatible server cabinet.
1.11 Front Bezel Features
The optional front bezel is made of molded plastic and uses a snap-on design. When installed, its design allows for maximum airflow to maintain system cooling requirements.
TP02100
Figure 10. Optional Front Bezel
Separate front bezels are available to support systems that use either a standard control panel or the Intel
®
Local Control Panel with LCD support.
When the standard control panel is used, light pipes on the backside of the front bezel allow the system status LEDs to be monitored with the front bezel in the closed position. The front bezel lock is provided to prevent unauthorized access to hard drives, peripheral devices and the control panel.
Revision – 1.00
Figure 11. Front Bezel Supporting Standard Control Panel
TP02101
Intel order number D31980-004
9
Product Overview Intel® Server System SR2500AL
When the local control panel is used, the control panel module can be adjusted to extend further out from the chassis face to allow the LCD panel to protrude from the front bezel.
AF000054
Figure 12. Front Bezel Supporting Intel
®
Local Control Panel
10
Intel order number D31980-004
Revision – 1.00
The power sub-system of the chassis consists of an integrated Power Distribution Module
(PDM), a power module enclosure, and support for up to two 750 Watt power supply modules.
The power sub-system can be configured to support a single module in a 1+0 non-redundant configuration, or dual modules in a 1+1 redundant power configuration. In a 1+1 configuration, a single failed power module can be hot-swapped with the system running. Either configuration will support up to a maximum of 750 Watts of power.
This chapter provides technical details to the operation of the power supply module and power sub-system. For additional information refer to the Intel
®
Server Chassis SR2500 AC Power
Supply Specification and the Intel
®
Server Chassis SR2500 Power Distribution Module
Specification.
The drawing below displays the Power Distribution Module and the power supply module enclosure assembly.
Figure 13. Mechanical Drawing for Dual (1+1 configuration) Power Supply Enclosure with PDM
Revision – 1.00
Intel order number D31980-004
11
Power Sub-System Intel® Server System SR2500AL
2.2 Single Power Supply Module Population
In single power module configurations, server management firmware requires that the power supply module be populated in the bottom power module slot. The non-operating slot must have the power supply blank installed.
AF000023
Figure 14. Power Supply Blank
Configuring a single power supply module in the top location will cause the server management firmware and BIOS to generate a system error during POST and the error will be reported to the
System Event Log (SEL).
2.3 Handle and Retention Mechanism
Each power supply module includes a handle for module insertion to or removal from the module enclosure. Each module has a simple retention mechanism to hold the power module in place once it is inserted. This mechanism will withstand the specified platform mechanical shock and vibration requirements. The tab on the retention mechanism is colored Green to indicate it is a hot-swap touch point. The latch mechanism is designed to prevent insertion or removal of the module with the power cord plugged in. This will aid the hot-swapping procedure.
Hot-swapping a power supply module is the process of extracting and re-inserting a power supply module from an operating power system. During this process the output voltages shall remain within specified limits. Up to two power supply modules may be on a single AC line.
The power supply module can be hot-swapped by the method listed below.
Extraction: on removal, the power cord is unplugged first, and then the power module is removed. This can be done in standby mode or power-on mode.
Insertion: The module is inserted first, and then the power cord is plugged in. If powered off, the system and the power supply will power on into standby mode or power-on mode.
12
Intel order number D31980-004
Revision – 1.00
2.5 Airflow
Each power supply module incorporates two non-redundant 40mm fans for self cooling and partial system cooling. The fans will provide no less than 10 CFM airflow through the power supply when installed in the system and operating at maximum fan speed. The cooling air will enter the power module from the PDB side (pre-heated air from the system).
2.6 AC Power Cord Specification Requirements
The AC power cord used must meet the following specification requirements:
Cable Type
Wire Size
Temperature Rating
Amperage Rating
Voltage Rating
SJT
16 AWG
105º C
13A
125V
2.7 Output Cable Harness
The power distribution board provides a cable harness providing connectors to the various system boards. The harness size, connectors, and pin outs are shown below. Listed or recognized component appliance wiring material (AVLV2), CN, rated 105
°
C min, 300Vdc min shall be used for all output wiring.
Length mm
90, 90° angle
115, 90° angle
100
150
220
Table 2. Power Harness Cable Definitions
To connector #
P1
No of pins
2x12
Description
Main Power Connector
P2
P3
P4
P5
2x4
1x5
2x4
2x5
Processor Power Connector
Server Board Signal Connector
Backplane Power Connector
Mid-plane Power Connector
Revision – 1.00
Intel order number D31980-004
13
Power Sub-System Intel® Server System SR2500AL
2.7.1 P1 – Server Board Power Connector
Connector housing: 24- Pin Molex* Mini-Fit Jr.
39-01-2245 or equivalent
Contact: Molex Mini-Fit, HCS, Female, Crimp 44476 or equivalent
Table 3. P1 Main Power Connector
PIN
1
SIGNALS
+3.3 VDC
18 AWG COLOR
Orange
PIN SIGNAL
13 +3.3 VDC
-12 VDC
14
5V RS
5 COM
Red
Red (24 AWG)
Black
6 +5 Red
7 COM
8 PWR OK
9 5Vsb
10 +12 V3
Black
Gray
Purple
Yellow/Blue
Yellow/Blue
17 COM
21 +5 VDC
23 +5 VDC
24 COM
2.7.2 P2 – Processor Power Connector
Connector housing: 8- Pin Molex 39-01-2085 or equivalent
Contact: Molex 44476-1111 or equivalent
18 AWG
COLORS
Orange
Blue
Black
Green
Black
Black
Black
N.C.
Red
Red
Red
Black
PIN
1
Table 4. P2 Processor Power Connector
SIGNAL
COM
18 AWG COLORS
Black
PIN
5
SIGNAL 18 AWG COLORS
+12 V1 Yellow
+12 Yellow
+12 Yellow/Black
+12 Yellow/Black
14
Intel order number D31980-004
Revision – 1.00
2.7.3 P3 – Power Signal Connector
Connector housing: 5-pin Molex 50-57-9705 or equivalent
Contacts: Molex 16-02-0087 or equivalent
Table 5. P3 Power Signal Connector
PIN
1
SIGNAL
I2C Clock (SCL)
2 I2C Data (SDL)
3 SMBAlert#
4 ReturnS
5 3.3RS
24 AWG COLORS
White/Green
White/Yellow
White
Black
White/Brown
2.7.4 P4 – Backplane Power Connector
Connector housing: 8 Pin Molex Mini-Fit Jr. PN# 39-01-2245 or equivalent
Contact: Molex Mini-Fit, HCS, Female, Crimp 44476 or equivalent
PIN
Table 6. P4 Hot Swap Backplane Power Connector
SIGNAL 18 AWG COLORS PIN SIGNAL 18 AWG COLORS
5 +12 Yellow/Green
6 +12 Yellow/Green
2.7.5 P5 Mid-plane Power Connector
Connector housing: 10 Pin Molex Mini-Fit Jr. 43025-1000 or equivalent
Contact: Molex Mini-Fit, HCS, Female, Crimp 43030-0007 or equivalent
PIN
1
3
4
+5V
+3.3V
Table 7. P5 Mid-plane Power Connector
SIGNAL
COM
20 AWG Colors
Black
Red
Orange
PIN SIGNAL 20 AWG Colors
6 +12 V4 Yellow/Green
7 +12 Yellow/Green
8
9
+12 V4
+12 V4
Yellow/Green
Yellow/Green
2.8 AC Input Requirements
The power supply module incorporates universal power input with active power factor correction, which reduces line harmonics in accordance with the EN61000-3-2 and JEIDA MITI standards. P
Revision – 1.00
Intel order number D31980-004
15
Power Sub-System Intel® Server System SR2500AL
2.8.1 Efficiency
The following table provides the required minimum efficiency level at various loading conditions.
These are provided at three different load levels; 100%, 50% and 20%. Efficiency is tested over an AC input voltage range of 115VAC to 220VAC.
Loading
Recommended Efficiency
Table 8. Efficiency
100% of maximum
~80%
50% of maximum
~83%
20% of maximum
~78%
2.8.2 AC Input Voltage Specification
The power supply must operate within all specified limits over the input voltage range shown in the following table.
PARAMETER
Line Voltage
(110)
Line Voltage
(220)
Frequency
MIN
90V rms
Table 9. AC Input Rating
RATED MAX
Start-up
Vac
140V rms
85Vac
±4Vac
180V rms
200-240 264V rms
-
Power
Off
Vac
75Vac
±5Vac
-
Max Input
AC Current
Max Rated
Input AC
Current
12 A rms
1,3
11.0A
rms
4
6.0 A rms
2,3
5.5A
rms
4
47 Hz 50/60Hz 63 Hz
Notes:
1. Maximum input current at low input voltage range shall be measured at 90Vac, at max load.
2. Maximum input current at high input voltage range shall be measured at 180VAC, at max load.
3. This is not to be used for determining agency input current markings.
4. Maximum rated input current is measured at 100VAC and 200VAC.
Harmonic distortion of up to 10% of the rated AC input voltage must not cause the power supply to go out of specified limits. The power supply shall power off at or below 75Vac ±5Vac. The power supply shall start up at or above 85VAC ±4Vac. Application of an input voltage below
85VAC shall not cause damage to the power supply or blow a fuse.
2.8.3 AC Line Dropout / Holdup
An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC line for any length of time. During an AC dropout of one cycle or less the power supply must meet dynamic voltage regulation requirements over the rated load. If the AC dropout lasts longer than one cycle the power supply should recover and meet all turn-on requirements. The power supply must meet the AC dropout requirement over rated AC voltages, frequencies, and output loading conditions. Any dropout of the AC line shall not cause damage to the power supply.
20ms Min when tested under the following conditions: Max combined load = 525W,
12ms Min when tested under the following conditions: Max combined load = 750W
2.8.4 AC Line 5 VSB Holdup
The 5VSB output voltage should stay in regulation under its full load (static or dynamic) during an AC dropout of 70ms min (=5VSB holdup time) whether the power supply is in ON or OFF state (PSON asserted or de-asserted).
16
Intel order number D31980-004
Revision – 1.00
AC line inrush current shall not exceed 40A peak for up to one-quarter of the AC cycle, after which, the input current should be no more than the specified maximum input current. The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device).
The power supply must meet the inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition as well as upon recovery after AC dropout of any duration, and over the specified temperature range (T op
). It is acceptable that AC line inrush current may reach up to 60A peak for up to 1 msec.
Protection circuits inside the PDB and the power supply shall cause the power supply’s main
+12V output to shut down, or shall cause a shut down of any of the three outputs on the PDB.
Either of these shutdowns will result in shutting down the entire power supply / PDB combination. If the power supply latches off due to a protection circuit tripping, an AC cycle
OFF for 15 seconds shall be able to reset the power supply and the PDB.
2.9.1 Over-Current Protection (OCP)
Each DC/DC converter output on the PDB shall have individual OCP protection circuits. The power supply and power distribution board (PS and PDB) shall shutdown and latch off after an over-current condition occurs. This latch shall be cleared by an AC power interruption. The following table provides the over-current limits. The values are measured at the PDB harness connectors. The DC/DC converters shall not be damaged from repeated power cycling in this condition. The +12V output from the power supply is divided on the PDB into four channels and each is limited to 240VA of power. There shall be current sensors and limit circuits to shut down the entire PS and PDB if the limit is exceeded. The limits are listed below.
Table 10. Over-Current Protection Limits / 240VA Protection
Output Voltage
+3.3V
+5V
-12V
+12V1
+12V2
+12V3
+12V4
MIN OCP TRIP LIMITS
110% min (= 26.4A min)
110% min (= 33A min)
125% min (= 0.625A min)
112.5% min (= 18.0A min)
112.5% min (= 18.0A min)
112.5% min (= 18.0A min)
112.5% min (= 18.0A min)
MAX OCP TRIP LIMITS
150% max (= 36A max)
150% max (= 45A max)
400% max (= 2.0A max)
20A max
20A max
20A max
20A max
2.9.2 Over-Voltage Protection (OVP)
Each DC/DC converter output on the PDB shall have individual OVP circuits built in and they shall be locally sensed. The PS and PDB shall shutdown and latch off after an over-voltage condition occurs. This latch shall be cleared by an AC power interruption. The following table provides the over-voltage limits. The values are measured at the PDB harness connectors. The voltage shall never exceed the maximum levels when measured at the power pins of the output harness connector during any single point of fail. The voltage shall never trip any lower than the minimum levels when measured at the power pins of the PDB connector.
Revision – 1.00
Table 11. Over-Voltage Protection (OVP) Limits
Intel order number D31980-004
17
Power Sub-System Intel® Server System SR2500AL
Output Voltage OVP MIN (V) OVP MAX (V)
+3.3V 3.9 4.5
+5VSB 5.7 6.5
+12V1/2/3/4 13.0 14.5
2.9.3 Over-Temperature Protection (OTP)
The power supply will be protected against over-temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition the power supply will shutdown.
When the power supply temperature drops to within specified limits, the power supply shall restore power automatically, while the 5 Vsb remains constantly on. The OTP trip level shall have a minimum of 4
°C of ambient temperature hysteresis, so that the power supply will not oscillate on and off due to a temperature recovery condition. The power supply shall alert the system of the OTP condition via the power supply FAIL signal and the PWR LED.
2.10 DC Output Specification
2.10.1 Output Power / Currents
The following table defines power and current ratings for this 750W continuous (860W pk) power supply in 1+0 or 1+1 redundant configuration. The combined output power of both outputs shall not exceed the rated output power. The power supply must meet both static and dynamic voltage regulation requirements for the minimum loading conditions. Also, the power supply shall be able to supply the listed peak currents and power for a minimum of 10 seconds.
Outputs are not required to be peak loaded simultaneously.
MAX Load
MIN DYNAMIC Load
MIN STATIC Load
PEAK Load
Max Output Power (continuous)
Peak Output Power
+12V +5Vsb
62.0A 3.0A
3.0A 0.1A
0.0A 0.1A
70.0A(12s min)
12V x 62A = 744W max
12V x 70A = 840W pk
5.0A (0.5s min @ turn-on)
5V x 3A = 15W max
5V x 5A = 25W pk
2.10.2 Standby Output / Standby Mode
The 5Vsb output shall be present when an AC input greater than the power supply turn-on AC voltage is applied. Applying an external 5.25V to 5Vsb shall not cause the power supply to shut down or exceed operating limits. When the external voltage is removed the voltage shall return to the power supplies operating voltage without exceeding the dynamic voltage limits.
18
Intel order number D31980-004
Revision – 1.00
2.11 Power Supply Status LED
Each power supply module will have a single bi-color LED to indicate power supply status. The
LED operation is defined below.
Table 12. LED Indicators
Power Supply Condition
No AC power to all power supplies
No AC power to this PSU only (for 1+1 configuration)
or
Power supply critical event causing a shutdown: failure, fuse blown (1+1 only), OCP, OVP, Fan Failed
Power supply warning events where the power supply continues to operate: high temp, high power, high current, slow fan.
AC present / Only 5VSB on (PS Off)
Output ON and OK
OFF
Bi-Color LED
AMBER
1Hz Blink AMBER
1Hz Blink GREEN
GREEN
The LED is visible on the rear panel of each installed power supply module.
Revision – 1.00
Intel order number D31980-004
19
Cooling Subsystem Intel® Server System SR2500AL
Several components and configuration requirements make up the cooling sub-system of the chassis. These include the system fan module, the power supply fans, air baffles, CPU air duct, and drive bay population. All are necessary to provide and regulate the air flow and air pressure needed to maintain the system’s thermals when operating at or below maximum specified thermal limits. See Table 55. System Environmental Limits.
Two system fan assembly options are available for this chassis. The first option is a nonredundant three fan solution providing sufficient airflow to maintain internal system thermal requirements when the external ambient temperature remains within specified limits. The second option is a redundant fan solution. Three parallel sets of fans are arranged in series to provide redundant cooling in the event of a single fan failure. Each cooling option utilizes two fan types: a 60mm variable speed fan and an 80mm variable speed fan.
The chassis uses a variable fan speed control engine to provide adequate cooling for the system at various ambient temperature conditions, under various server workloads, and with the least amount of acoustic noise possible. The fans operate at the lowest speed for any given condition in order to minimize acoustics. The Baseboard Management Controller (BMC) integrated on the Intel
®
Server Board S5000PAL is used for the variable fan speed control function. The controller monitors selective component temperatures and the ambient temperature, as well as each fan’s RPM to determine the necessary airflow. The BMC sets the fan speeds to the appropriate RPM in order to maintain proper cooling. The BMC controller will also log errors into the System Event Log (SEL) when temperature sensors exceed their safe operating ranges, or if any of the fans fail to operate at safe airflow speeds. In the event of a fan failure, the BMC will boost the remaining fans to compensate for the lost air flow. A chassis with redundant fans can continue to operate in this degraded condition while the non-redundant chassis may not. If the cooling is not sufficient under a failed fan condition, the system will eventually shutdown to protect itself from thermal damage.
20
Intel order number D31980-004
Revision – 1.00
3.1 Non-redundant Fan Module
TP02119
Figure 15. Non-Redundant Fan Module
This option provides the primary airflow for system configurations that do not require redundant cooling.
Table 13 Nonredundant Cooling Zones
Fan
System Fan #1
System Fan #2
System Fan #3
Power Supply
Fans 2 fans per module
Cooling
Zone
CPU1
CPU2
PCI
Power
Supply
Description of greatest cooling influence
Primary cooling for CPU1 and memory
Primary cooling for hard drives 4 and 5, CPU2, the MCH, and the low profile PCI cards
Primary cooling for hard drives 2 and 3, Full
Height PCI cards, PXH and IOP80333 chipset
Primary cooling for hard drives 0 and 1, and the power supply module(s)
The system fan module has been designed for ease of use and has support for several management features that can be utilized by the server board management system.
• The fan module houses two different fan sizes. System fans 1 and 2 use an 80mm fan, while system fan 3 uses a 60mm fan.
• Each fan is designed for tool-less insertion to or removal from the fan module housing.
Note: The fans are NOT hot-swappable. The system must be turned off in order to replace a failed fan.
• Each fan within the module is capable of supporting multiple speeds. If the internal ambient temperature of the system exceeds the value programmed into the thermal sensor data record (SDR), the BMC firmware will increase the speed for all the fans within the fan module.
• Each fan connector within the module supplies a tachometer signal that allows the BMC to monitor the status of each fan. If one of the fans should fail, the remaining fans will increase their rotation and attempt to maintain the thermal requirements of the system.
Revision – 1.00
Intel order number D31980-004
21
Cooling Subsystem Intel® Server System SR2500AL
• Each fan has an associated fault LED on the mid-plane located next to the fan header.
In the event of a fan failure, the fault LED for the failing fan can be illuminated by system management.
Table 14. Non-redundant Fan Connector Pin Assingment
Pin Signal Name Description
2 PWM
3 12V
4 12V
Fan speed control signal
Power for fan
Power for fan
5 Tachometer A Fan RPM sensor output
Two pulse per revolution for the 80mm fan
Four pulses per revolution for the 60mm fan
6 Return Return path to ground
7 Return Return path to ground
9 LED Cathode Loopback signal to pin 10
10 LED Anode Loopback signal to pin 9
The system fans plug into headers on the mid-plane board according to the following diagram.
3
2
1
22
Figure 16. Non-Redundant Fan Header Assignments on Mid-plane
Intel order number D31980-004
Revision – 1.00
Table 15. Nonredundant Fan Header Assignment
Fan ID
Fan #1 - CPU1 cooling
Fan #2 - CPU2 cooling
Fan #3 - PCI Cooling
Mid-plane Fan Header Name
FAN_2
FAN_4
FAN_6
3.2 Redundant System Fan Module
TP02102
Figure 17. Fan Module Assembly
Table 16 Redundant Cooling Zones
Fan
System Fan #1 & #2
System Fan #2 & #3
System Fan #5 & #6
Power Supply Fans 2 fans per module
Cooling
Zone
Description of greatest cooling influence
CPU1 Primary cooling for CPU1 and memory
CPU2 Primary cooling for hard drives hard drives 4 and
5, CPU2, the BNB, and the low profile PCI cards
PCI
Power
Supply
Primary cooling for hard drives 2 and 3, Full
Height PCI cards, PXH and IOP80333 chipset
Primary cooling for hard drives 0 and 1, and the power supply module(s)
Each 10-pin fan connector provides power and ground, PWM control, tachometer output, a fan present detection signal, and a fault LED signal allowing it to be monitored independently by server management software. The following table provides the pin-out and description for the connectors on each fan.
Revision – 1.00
Intel order number D31980-004
23
Cooling Subsystem Intel® Server System SR2500AL
Table 17 Redundant Fan Connector Pin Assingment
Pin Signal Name Description
2 PWM
3 12V
4 12V
Fan speed control signal
Power for fan
Power for fan
5 Tachometer A Fan RPM sensor output
Two pulses per revolution for the 80mm fan
Four pulses per revolution for the 60mm fan
6 Return Return path to ground
7 Return Return path to ground
8 Fan Presence Detection if fan is installed in system
9 LED Cathode LED in fan
10 LED Anode Reserved, unused by the redundant fan
The system fans are hot-pluggable and do not have any cable connections. They mate directly to the fan module. The system fan module plugs into headers on the mid-plane board according the following diagram.
5
6
4
3
2
1
24
Figure 18. Redudant Fan Header Assignments on Mid-plane
AF000049
Intel order number D31980-004
Revision – 1.00
Table 18 Redundant Fan Header Assignment
Fan ID
Fan #1 - CPU1 Cooling
Fan #2 - CPU1 Cooling
Fan #3 - CPU2 Cooling
Fan #4 - CPU2 Cooling
Fan #5 - PCI Cooling
Fan #6 - PCI Cooling
Mid-plane Fan Header Name
FAN_1
FAN_2
FAN_3
FAN_4
FAN_5
FAN_6
The system fan module has been designed for ease of use and has support for several management features that can be utilized by the server board management system.
• The fan module houses two different fan sizes. System fans 1, 2, 3 and 4 use an 80mm fan, while system fans 5 and 6 use a 60mm fan.
• Each fan is designed for tool-less insertion to or removal from the fan module and can be hot-swapped in the event of failure.
• Each fan within the module is equipped with a failure LED. In the event of a fan failure, the failure LED on the failing fan can be illuminated by server management.
• Each fan within the module is capable of supporting multiple speeds. If the internal ambient temperature of the system exceeds the value programmed into the thermal sensor data record (SDR), the BMC firmware will increase the speed for all the fans within fan module.
• Each fan connector within the module supplies a tachometer signal that allows the BMC to monitor the status of each fan. If one of the fans should fail, the remaining fans will increase their rotation and attempt to maintain the thermal requirements of the system.
3.3 Air Flow Support
To control airflow within the system, the chassis uses an air baffle and a CPU air duct to isolate and direct airflow to three critical zones: the power supply zone, the full height PCI riser zone, and the CPU/memory/low profile PCI riser zone.
3.3.1 Power Supply Zone
An air baffle is used to isolate the air flow of the main system board zones from the zone directly behind the power supply. As the power supply fans pull pre-heated air through the power supply from inside the chassis, the zone behind it must remain as cool as possible by drawing air from the leftmost drive bays only.
3.3.2 Full Height Riser Zone
The full height riser zone is the area between the power supply assembly and the full height riser card of the riser assembly. The air flow through this area is generated by system fan 3 of the fan module in a non-redundant fan configuration. In a redundant fan configuration, the air flow for this zone is provided by system fans 5 and 6. Air is drawn from the drive bay area through the fan and pushed out of the system through ventilation holes the back side of the chassis.
Revision – 1.00
Intel order number D31980-004
25
Cooling Subsystem Intel® Server System SR2500AL
3.3.3 CPU / Memory / Low Profile PCI Zone
The CPU / memory / low profile PCI zone is the area between the low profile riser card of the riser assembly and the right chassis wall. In a non-redundant fan configuration, the air flow for this zone is generated by system fans 1 and 2 of the fan module. In a redundant fan configuration, the air flow for this zone is provided by system fans 1, 2, 3 and 4. Air is drawn from the drive bay area, through the fans, directed through the CPU air duct, and out through ventilation holes on both the back wall and rear side wall of the chassis.
The CPU air duct is used to direct air flow through the processor heat sinks for both single and dual processor configurations. For single processor configurations, a flexible air baffle is attached to the air duct as shown in the following diagram.
26
AF000048
Figure 19. CPU Air Duct with Air Baffle
Operating a single processor configuration without the air baffle installed will result in the processor over heating and may cause the system to shutdown.
3.4 Drive Bay Population
To maintain the proper air pressure within the system, all hard drive bays must be populated with either a hard drive, or drive blank.
Figure 20. Drive Blank
TP02104
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
4. System Board Interconnects
System Board Interconnects
The chassis incorporates several design changes from the previous generation Intel 2U server chassis, resulting in improved cable routing. System boards within the chassis include the midplane, bridge board, hot-swap backplane, and control panel. This chapter describes the interconnect features of each, and defines the pin-outs for each of their connectors. Functional details of each system board are described in later chapters.
4.1 Mid-plane
The mid-plane is new to this generation of Intel high density server platforms. Its design and use, along with that of the bridgeboard and hot-swap backplane, improve cable routing within the system. The mid-plane is the key system board of the chassis. It serves as the primary interface between the server board, hot-swap backplane, and control panel. Two mid-planes are offered for this chassis: a passive SATA/SAS, and an active SAS/SAS RAID.
The passive midplane is a simple pass through from the backplane to the SATA connectors on the baseboard or SAS/SATA connectors on an add-in card.
The following diagram shows the location for each connector found on the passive mid-plane board.
B
C
A D
E
F
G
H
I
J
AF000047
Figure 21. Passive Mid-plane Board
A
B
Power Connector
Fan 6 Connector
C Fan 5 Connector
D SAS/SATA Connectors
E Bridge Board Connector
F Fan 4 Connector
G Fan 3 Connector
H Fan 1 Connector
I
J
Fan 2 Connector
Backplane Connector
Revision – 1.00
Intel order number D31980-004
27
System Board Interconnects Intel® Server System SR2500AL
The chassis also supports an active SAS / SAS RAID mid-plane. This system board incorporates an LSI* LSISAS1068 SAS controller onto the board. See Chapter 5 for details describing SAS / SAS RAID support. The following diagram shows the location for each connector found on this board.
C
A
B D
E
F
G
H
I
J
L
K
AF000046
Figure 22. SAS/SAS RAID Mid-plane Board
A
RAID Activation Key
Connector
B Power Connector
C Mini-DIMM Connector
D Fan 6 Connector
E Fan 5 Connector
F Bridge Board Connector
G Fan 4 Connector
H Fan 3 Connector
I Fan 1 Connector
J
K
Fan 2 Connector
Battery
L Backplane Connector
The following tables define the connector pin-outs for both mid-plane boards.
28
Table 19. 120-pin Server Board-to-Mid-plane Bridge Board Connector Pin-out
PIN SIGNAL NAME
1 GND
2 PE1_ESB_TX_DN3
3 PE1_ESB_TX_DP3
4 GND
5 PE_WAKE_N
6 GND
7 PE1_ESB_TX_DN2
8 PE1_ESB_TX_DP2
9 GND
10 FAN_PRSNT5_N
11 GND
12 PE1_ESB_TX_DN1
PIN SIGNAL NAME
61 SMB_SENSOR_3V3SB_CLK_BUF
62 SMB_SENSOR_3V3SB_DAT_BUF
63 FM_BRIDGE_PRSNT_N
64 GND
65 PE1_ESB_RX_DN_C3
66 PE1_ESB_RX_DP_C3
67 GND
68 FAN_PRSNT6_N
69 GND
70 PE1_ESB_RX_DN_C2
71 PE1_ESB_RX_DP_C2
72 GND
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
PIN SIGNAL NAME
13 PE1_ESB_TX_DP1
14 GND
15 RST_PS_PWRGD
16 GND
17 PE1_ESB_TX_DN0
18 PE1_ESB_TX_DP0
19 GND
20 FM_RAID_MODE
21 GND
22 CLK_IOP_DN
23 CLK_IOP_DP
24 GND
25 SGPIO_DATAOUT1
26 SGPIO_DATAOUT0
27 SGPIO_LOAD
28 SGPIO_CLOCK
29 GND
30 USB2_ESB_DP
31 USB2_ESB_DN
32 GND
33 USB2_ESB_OC_N
34 NIC1_LINK_LED_N
35 NIC1_ACT_LED_N
36 LED_STATUS_AMBER_R1
37 NIC2_LINK_LED_N
38 NIC2_ACT_LED_N
39 LED_STATUS_GREEN_BUF_R1
40 GND
41 SMB_PBI_5VSB_DAT
42 SMB_PBI_5VSB_CLK
43 GND
44 V_IO_HSYNC2_BUF_FP
45 V_IO_VSYNC2_BUF_FP
46 GND
47 V_IO_BLUE_CONN_FP
48 V_IO_GREEN_CONN_FP
49 V_IO_RED_CONN_FP
50 GND
51 LED_FAN6_FAULT
52 LED_FAN5_FAULT
53 LED_FAN4_FAULT
54 FAN_PWM3
55 GND
56 PCI_FAN_TACH10
57 FAN_TACH8
58 FAN_TACH6
59 FAN_TACH4_H7
60 FAN_TACH2_H7
System Board Interconnects
PIN SIGNAL NAME
73 FAN_PRSNT4_N
74 GND
75 PE1_ESB_RX_DN_C1
76 PE1_ESB_RX_DP_C1
77 GND
78 RAID_KEY_PRES
79 GND
80 PE1_ESB_RX_DN_C0
81 PE1_ESB_RX_DP_C0
82 GND
83 FAN_PRSNT1_N
84 FAN_PRSNT3_N
85 FAN_PRSNT2_N
86 GND
87 USB1_ESB_DP
88 USB1_ESB_DN
89 GND
90 USB1_ESB_OC_N
91 USB0_ESB_OC_N
92 GND
93 USB0_ESB_DP
94 USB0_ESB_DN
95 GND
96 FP_NMI_BTN_N
97 BMC_RST_BTN_N
98 FP_PWR_BTN_N
99 FP_ID_SW_L
100 GND
101 SMB_IPMB_5VSB_DAT
102 SMB_IPMB_5VSB_CLK
103 GND
104 LED_HDD_ACTIVITY_N
105 LED_HDD_5V_A
106 FP_PWR_LED_R_N
107 FP_PWR_LED_3VSB
108 FP_ID_LED_R1_N
109 FM_SIO_TEMP_SENSOR
110 LED_FAN3_FAULT
111 LED_FAN2_FAULT
112 LED_FAN1_FAULT
113 FAN_PWM_CPU1
114 GND
115 FAN_PWM_CPU2
116 PCI_FAN_TACH9
117 FAN_TACH7
118 FAN_TACH5
119 FAN_TACH3_H7
120 FAN_TACH1_H7
Revision – 1.00
Intel order number D31980-004
29
System Board Interconnects Intel® Server System SR2500AL
Table 20. Mid-plane Fan Header Pin-outs
J2B1 - FAN_1
PIN SIGNAL NAME
1 FAN_TACH5
2 FAN_PWM_CPU1
3 P12V
4 P12V
5 FAN_TACH1_H7
6 GND
7 GND
8 FAN_PRSNT1_N
9 LED_FAN1_FAULT
10 LED_FAN1
J2B2 - FAN_2
PIN SIGNAL NAME
1 FAN_TACH6
2 FAN_PWM_CPU1
3 P12V
4 P12V
5 FAN_TACH2_H7
6 GND
7 GND
8 FAN_PRSNT2_N
9 LED_FAN2_FAULT
10 LED_FAN2
J2B3 - FAN_3
PIN SIGNAL NAME
1 FAN_TACH7
2 FAN_PWM_CPU2
3 P12V
4 P12V
5 FAN_TACH3_H7
6 GND
7 GND
8 FAN_PRSNT3_N
9 LED_FAN3_FAULT
10 LED_FAN3
J3B1 - FAN_4
PIN SIGNAL NAME
1 FAN_TACH8
2 FAN_PWM_CPU2
3 P12V
4 P12V
5 FAN_TACH4_H7
6 GND
7 GND
8 FAN_PRSNT4_N
9 LED_FAN4_FAULT
10 LED_FAN4
J7B1 - FAN_5
PIN SIGNAL NAME
1 FAN_TACH10
2 FAN_PWM3
3 P12V
4 P12V
5 FAN_TACH9
6 GND
7 GND
8 FAN_PRSNT5_N
9 LED_FAN5_FAULT
10 LED_FAN5
J7B2 - FAN_6
PIN SIGNAL NAME
1 UNUSED
2 FAN_PWM3
3 P12V
4 P12V
5 FAN_TACH10
6 GND
7 GND
8 FAN_PRSNT6_N
9 LED_FAN6_FAULT
10 LED_FAN6
Table 21. Mid-plane Power Connector Pin-out
PIN Signal Description
1 GND
2 GND
3 P5V
4 P3V3
5 GND
6 P12V
7 P12V
8 P12V
9 P12V
10 P5V_STBY
30
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL System Board Interconnects
PIN SIGNAL NAME
A1 RST_PS_PWRGD
A2 GND
A3 GND
A4 SATA1_RX_N
A5 SATA1_RX_P
A6 GND
A7 GND
A8 SATA1_TX_P
A9 SATA1_TX_N
A10 GND
A11 GND
A12 USB2_ESB_OC_N
A13 GND
A14 GND
A15 SATA3_RX_N
A16 SATA3_RX_P
A17 GND
A18 GND
A19 GND
A20 SATA3_TX_P
A21 SATA3_TX_N
A22 GND
A23 GND
A24 SATA5_RX_N
A25 SATA5_RX_P
A26 GND
A27 GND
A28 SATA5_TX_P
A29 SATA5_TX_N
A30 GND
A31 GND
A32 P5V_STBY
Table 22. Mid-plane-to-Backplane Card Edge Connector #1 Pin-out
J7A1 - HSBP#1 I/F
PIN SIGNAL NAME
B1 GND
B2 SATA0_RX_N
B3 SATA0_RX_P
B4 GND
B5 GND
B6 SATA0_TX_N
B7 SATA0_TX_P
B8 GND
B9 GND
B10 USB2_ESB_DN
B11 USB2_ESB_DP
B12 GND
B13 SATA2_RX_N
B14 SATA2_RX_P
B15 GND
B16 NC_RESERVEDB16
B17 SMB_SAS_EDGE_DAT
B18 NC_RESERVEDB18
B19 SMB_SAS_EDGE_CLK
B20 NC_RESERVEDB20
B21 GND
B22 SATA2_TX_P
B23 SATA2_TX_N
B24 GND
B25 GND
B26 SATA4_RX_N
B27 SATA4_RX_P
B28 GND
B29 GND
B30 SATA4_TX_P
B31 SATA4_TX_N
B32 GND
Revision – 1.00
Intel order number D31980-004
31
System Board Interconnects Intel® Server System SR2500AL
Table 23. Mid-plane-to-Backplane Card Edge Connector #2 Pin-out
PIN SIGNAL NAME
A1 SGPIO_DATAOUT0
A2 SGPIO_DATAOUT1
A3 GND
A4 GND
A5 SATA_ADDIN2_RX_N
A6 SATA_ADDIN2_RX_P
A7 GND
A8 GND
A9 SATA_ADDIN2_TX_P
A10 SATA_ADDIN2_TX_N
A11 GND
A12 SMB_PBI_3VSB_DAT
A13 SMB_PBI_3VSB_CLK
A14 USB0_ESB_OC_N
A15 GND
A16 GND
A17 USB0_ESB_DP
A18 USB0_ESB_DN
A19 GND
A20 LED_NIC1_ACT_N
A21 LED_NIC1_LINK_N
A22 FM_SIO_TEMP_SENSOR
A23 LED_NIC2_LINK_N
A24 LED_NIC2_ACT_N
A25 GND
A26 V_BLUE_CONN_FP
A27 V_GREEN_CONN_FP
A28 V_RED_CONN_FP
A29 GND
A30 V_HSYNC2_BUF_FP
A31 V_VSYNC2_BUF_FP
A32 GND
J4A1 - HSBP#2 I/F
PIN SIGNAL NAME
B1 SGPIO_CLOCK
B2 GND
B3 SATA_ADDIN1_RX_N
B4 SATA_ADDIN1_RX_P
B5 GND
B6 GND
B7 SATA_ADDIN1_TX_N
B8 SATA_ADDIN1_TX_P
B9 GND
B10 GND
B11 SGPIO_LOAD
B12 SMB_IPMB_5VSB_DAT
B13 SMB_IPMB_5VSB_CLK
B14 GND
B15 USB1_ESB_DP
B16 USB1_ESB_DN
B17 GND
B18 GND
B19 USB1_ESB_OC_N
B20 LED_HDD_ACTIVITY_N
B21 LED_HDD_5V_A
B22 FP_ID_SW_L
B23 BMC_RST_BTN_N
B24 FP_PWR_BTN_N
B25 FP_NMI_BTN_N
B26 FP_PWR_LED_3VSB
B27 FP_PWR_LED_R_N
B28 FP_ID_LED_R1_N
B29 GND
B30 LED_STATUS_AMBER_R1
B31 LED_STATUS_GREEN_BUF_R1
B32 FP_LED
32
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL System Board Interconnects
Table 24. Active Mid-plane SAS RAID Battery Backup Connector Pin-out
PIN Signal Description
1 P12V
2 GND
3 NC_P5V_MONITOR
4 GND
5 P1V8_VBAT_RAID
6 GND
7 PWRGD_P3V3_STBY
8 GND
9 P1V8_VBAT_RAID
10 GND
11 PX_RESET_N
12 GND
13 SMB_CLK_P3V3
14 GND
15 SMB_DAT_P3V3
16 BBU_PFAIL_N
17 BBU_DDR_SEL
18 BBU_BBE
19 BBU_BBSTROBE
20 BBU_BBSTATUS
Table 25. Passive Mid-plane SATA/SAS Connector Pin-outs
J5A2 - SAS_7
PIN SIGNAL NAME
1 GND
J6A1 - SAS_6 J5B1 - SAS_4 J6B1 - SAS_2
PIN SIGNAL NAME PIN SIGNAL NAME PIN SIGNAL NAME
1 GND 1 GND 1 GND
2 SATA_ADDIN1_TX_P 2 SATA5_TX_P
3 SATA_ADDIN1_TX_N 3 SATA5_TX_N
4 GND 4 GND
5 SATA_ADDIN1_RX_N 5 SATA5_RX_N
6 SATA_ADDIN1_RX_P 6 SATA5_RX_P
7 GND 7 GND
2 SATA3_TX_P
3 SATA3_TX_N
4 GND
5 SATA3_RX_N
6 SATA3_RX_P
7 GND
2 SATA1_TX_P
3 SATA1_TX_N
4 GND
5 SATA1_RX_N
6 SATA1_RX_P
7 GND
J5A1- SAS_8 J6A2 - SAS_5 J5B2 - SAS_3 J6B2 - SAS_1
PIN SIGNAL NAME
1 GND
PIN SIGNAL NAME
1 GND
2 SATA_ADDIN2_TX_P 2 SATA4_TX_P
PIN SIGNAL NAME
1 GND
2 SATA2_TX_P
PIN SIGNAL NAME
1 GND
2 SATA0_TX_P
3 SATA_ADDIN2_TX_N 3 SATA4_TX_N
4 GND 4 GND
5 SATA_ADDIN2_RX_N 5 SATA4_RX_N
6 SATA_ADDIN2_RX_P 6 SATA4_RX_P
7 GND 7 GND
3 SATA2_TX_N
4 GND
5 SATA2_RX_N
6 SATA2_RX_P
7 GND
3 SATA0_TX_N
4 GND
5 SATA0_RX_N
6 SATA0_RX_P
7 GND
Revision – 1.00
Intel order number D31980-004
33
System Board Interconnects Intel® Server System SR2500AL
4.2 Bridge Board
The chassis utilizes a bridge board to route signals from the server board to the mid-plane board. The bridge board carries signals for three USB ports, SSI front panel control signals, video, various I2C buses, fan control signals, and a PCIe* x4 bus for SAS controller function.
See Table 19. 120-pin Server Board-to-Mid-plane Bridge Board Connector Pin-out.
AF000037
Figure 23. Bridge Board
4.3 Hot-Swap SATA/SAS Backplane
The hot swap backplane provides support for both SAS and SATA hard drives. There are no hard drive cables that connect to the backplane. All hard drive control signals are routed from the mid-plane board which plugs directly into the backplane.
34
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
A
B
System Board Interconnects
C
D
AF000045
Figure 24. Hot-Swap SAS/SATA Backplane (Front Side View)
A Slimline Optical Drive Connector
B USB Floppy Connector
C Control Panel Connector
D SAS/SATA Hot Swap Connectors
A
B C
D
E
AF000044
Revision – 1.00
Figure 25. Hot-Swap SAS/SATA Backplane (Back Side View)
A Power Connector (for 6 th
Hard Drive or
SATA Tape Drive)
B SAS/SATA Connector (for 6 th
Hard
Drive or SATA Tape Drive)
Intel order number D31980-004
35
System Board Interconnects Intel® Server System SR2500AL
Table 26. 2x4 SAS/SATA Backplane Power Connector Pin-out (J7L2)
Pin # Signal Name
1 Ground
2 Ground
3 P5V
4 P5V
5 P12V
6 P12V
7 P5V_STBY
8 P3V3
Table 27. 1x7 6th HDD / Tape Drive Option Power Connector Pin-out (J2M1)
Pin # Signal Name
1 P12V
2 Ground
3 Ground
4 P5V
5 SASS_PRSTNT_L
6 LED_SASS_ACT_L
7 P3V3
Table 28. 6th HDD Option SATA/SAS I/O Connector Pin-out (J4L1)
Pin # Signal Name
1 Ground
2 SASS_TX_DP
3 SASS_TX_DN
4 Ground
5 SASS_RX_DN
6 SASS_RX_DP
7 Ground
36
Table 29. 2x22 Slim-Line IDE Optical Drive Connector Pin-out (J5N1)
Pin # Signal Name
1 RST_IDE_L
2 Ground
3 RIDE_DD <15..0> 7
4
5
6
7
RIDE_DD <15..0> 8
RIDE_DD <15..0> 6
RIDE_DD <15..0> 9
RIDE_DD <15..0> 5
8
9
RIDE_DD <15..0> 10
RIDE_DD <15..0> 4
10 RIDE_DD <15..0> 11
11 RIDE_DD <15..0> 3
12 RIDE_DD <15..0> 12
13 RIDE_DD <15..0> 2
Pin # Signal Name
23 RIDE_DIOW_N
24 Ground
25 RIDE_DIOR_N
26 Ground
27 RIDE_DIORDY
28 IDE_ALE_H
29 RIDE_DDACK_N
30 Ground
31 IRQ_IDE
32 TP_PIDE_32
33 RIDE_DA1
34 IDE_PRI_CBLSNS
35 RIDE_DA0
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
Pin # Signal Name
14 RIDE_DD <15..0> 13
15 RIDE_DD <15..0> 1
16 RIDE_DD <15..0> 14
17 RIDE_DD <15..0> 0
18 RIDE_DD <15..0> 15
19 Ground
20 Not Used
21 RIDE_DDREQ
22 Ground
System Board Interconnects
Pin # Signal Name
36 RIDE_DA2
37 RIDE_DCS1_N
38 RIDE_DCS3_N
39 LED_IDE_L
40 Ground
42 Not Used
Pin # Signal Name
A1 RST_IDE_L
A2 Ground
A3 RIDE_DD<15..0> 7
A4 Ground
A5 RIDE_DD<15..0> 6
A6 Ground
A7 RIDE_DD<15..0> 5
A8 Ground
A9 RIDE_DD<15..0> 4
A10 Ground
A11 RIDE_DD<15..0> 3
A12 Ground
A13 RIDE_DD<15..0> 2
A14 Ground
A15 RIDE_DD<15..0> 1
A16 Ground
A17 RIDE_DD<15..0> 0
A18 Ground
A19 RIDE_DIOW_N
A20 Ground
A21 RIDE_DIORDY
A22 Ground
A23 IRQ_IDE
A24 Ground
A25 RIDE_DA1
A26 Ground
A27 RIDE_DA0
A28 Ground
A29 RIDE_DCS1_N
A30 P5V
A31 P5V
A32 LED_IDE_L
Table 30. Slim-Line Optical Drive Slot Connector (J1A1)
PRSNT1_N 12V
12V 12V
12V RSVD
GND GND
JTAG2 SMCLK
JTAG3 SMDAT
JTAG4 GND
JTAG5 3_3V
3_3V JTAG1
3_3V 3_3VAUX
PERST_N WAKE_N
---------------KEY --------------------
GND RSVD
REFCLK+ GND
REFCLK – PETP0
GND PETN0
PERP0 GND
PERN0 PRSNT2_N
GND GND
RSVD PETP1
GND PETN1
PERP1 GND
PERN1 GND
GND PETP2
GND PETN2
PERP2 GND
PERN2 GND
GND PETP3
GND PETN3
PERP3 GND
PERN3 RSVD
GND PRSNT2_N
RSVD GND
Pin # Signal Name
B1 RIDE_DD<15..0> 8
B2 Ground
B3 RIDE_DD<15..0> 9
B4 Ground
B5 RIDE_DD<15..0> 10
B6 Ground
B7 RIDE_DD<15..0> 11
B8 Ground
B9 RIDE_DD<15..0> 12
B10 Ground
B11 RIDE_DD<15..0> 13
B12 Ground
B13 RIDE_DD<15..0> 14
B14 Ground
B15 RIDE_DD<15..0> 15
B16 Ground
B17 RIDE_DDREQ
B18 Ground
B19 RIDE__DIOR_N
B20 Ground
B21 RIDE_DDACK_N
B22 TP_PIDE_32
B23 IDE_PRI_CBLSNS
B24 Ground
B25 RIDE_DA2
B26 Ground
B27 RIDE_DCS3_N
B28 P5V
B29 P5V
B30 P5V
B31 IDE_ALE_S_H
B32 Ground
Table 31. IDE Device Master/Slave Configuration Jumper (J6L1)
Jumper
Setting
Configuration
Revision – 1.00
Table 32. I2C Connector (J6L3)
Pin # Signal Description
Intel order number D31980-004
37
System Board Interconnects
1 SMB_VSC_12C_DAT0
2 GROUND
3 SMB_VSC_12C_CLK0
Intel® Server System SR2500AL
Table 33. PCIe X4 Slot Connector from Mid-plane (J4N1)
Pin
#
Signal Name
A1 SGPIO_DATA0
A2 SGPIO_DATA1
A3 Ground
A4 Ground
A5 SAS7_RX_DN
A6 SAS7_RX_DP
A7 Ground
A8 Ground
Pin
#
Signal Name
B1 SGPIO_CLOCK
B2 Ground
B3 SAS6_RX_DN
B4 SAS6_RX_DP
B5 Ground
B6 Ground
B7 SAS6_TX_DN
B8 SAS6_TX_DP
A9 SAS7_TX_DP
A10 SAS7_TX_DN
B9 Ground
B10 Ground
A11 Ground B11 SGPIO_LOAD
A12 SMB_PB1_5VSB_DAT B12 SMB_IPMB_5VSB_DAT
A13 SMB_PB1_5VSB_CLK
A14 USB_OC1_N
A15 Ground
A16 Ground
B13 SMB_IPMB_5VSB_CLK
B14 Ground
B15 USB_P2P
B16 USB_P2N
A17 USB_P1P
A18 USB_P1N
A19 Ground
A20 LED_NIC1_ACT_L
A21 LED_NIC1_LINK_R_L
B17 Ground
B18 Ground
B19 USB_OC2_N
B20 LED_HDD_ACT_R_L
B21 PV_HDD_LED_3V_A
A22 FP_THERM_SENSOR
A23 LED_NIC2_LINK_R_L
A24 LED_NIC2_ACT_L
A25 Ground
B22 FP_ID_SW_L
B23 RST_FP_BTN_L
B24 FP_PWR_BTN_L
B25 FP_NMI_BTN_L
A26 V_IO_BLUE_CONN_FP B26 FP_PWR_LED_5VSB
A27 V_IO_GREEN_CONN_FP B27 LED_FP_PWR_R_L
A28 V_IO_RED_CONN_FP B28 LED_FP_ID_R_L
A29 Ground B29 Ground
A30 V_IO_HSYNC_BUFF_FP_L B30 LED_FP_SYS_FLT1_R_L
A31 V_IO_VSYNC_BUFF_FP_L B31 LED_FP_SYS_FLT2_R_L
A32 Ground B32 FP_FLT_LED_5VSB
38
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL System Board Interconnects
Table 34. PCIe X4 Slot Connector from Mid-plane (J6N1)
Pin
#
Signal Name
A1 RST_PWRGD_PS
A2 Ground
A3 Ground
A4 SAS1_RX_DN
A5 SAS1_RX_DP
A6 Ground
A7 Ground
A8 SAS1_TX_DP
A9 SAS1_TX_DN
A10 Ground
A11 Ground
A12 USB_OC3_N
A13 Ground
A14 Ground
A15 SAS3_RX_DN
A16 SAS3_RX_DP
A17 Ground
A18 Ground
A19 Ground
A20 SAS3_TX_DP
A21 SAS3_RT_DN
A22 Ground
A23 Ground
A24 SAS5_RX_DN
A25 SAS5_RX_DP
A26 Ground
A27 Ground
A28 SAS5_TX_DP
A29 SAS5_TX_DN
A30 Ground
A31 Ground
A32 P5V_STBY
Pin
#
Signal Name
B1 Ground
B2 SAS0_RX_DN
B3 SAS0_RX_DP
B4 Ground
B5 Ground
B6 SAS0_TX_DN
B7 SAS0_TX_DP
B8 Ground
B9 Ground
B10 USB_P3N
B11 USB_P3P
B12 Ground
B13 SAS2_RX_DN
B14 SAS2_RX_DP
B15 Ground
B17 SMB_SAS_3V3_SDA
B19 SMB_SAS_3V3_SCL
B21 Ground
B22 SAS2_TX_DP
B23 SAS2_TX_DN
B24 Ground
B25 Ground
B26 SAS4_RX_DN
B27 SAS4_RX_DP
B28 Ground
B29 Ground
B30 SAS4_TX_DP
B31 SAS4_TX_DN
B32 Ground
Table 35. USB Floppy Drive Connector (J2A1)
Pin # Signal Description
1 P5V_USB_FP_P3
2 USB_P3N
3 USB_P3P
4 Ground
Revision – 1.00
Intel order number D31980-004
39
System Board Interconnects Intel® Server System SR2500AL
Table 36. Intel
®
Local Control Panel (LCP) Connector (J9A1)
Pin # Signal Description
1 SMB_IPMB_5VSB_DAT
2 Ground
3 SMB_IPMB_5VSB_CLK
4 P5V_STBY_R
Table 37. Control Panel Slot Connector (J9B1)
Pin # Signal Name
A1 Ground
A2 V_IO_VSYNC_BUFF_FP_L
A3 Ground
A4 V_IO_HSYNC_BUFF_FP_L
A5 Ground
A6 V_IO_BLUE_BUFF_FP_L
A7 Ground
A8 V_IO_GREEN_BUFF_FP_L
A9 Ground
A10 V_IO_RED_BUFF_FP_L
A11 Ground
A12 Ground
A13 RST_FP_BTN_L
A14 Ground
A15 FP_CHASSIS_INTRU
A16 Ground
A17 SMB_PB1_5VSB_DAT
A18 SMB_PB1_5VSB_CLK
A19 Ground
A20 FP_NMI_BTN_L
A21 Ground
A22 USB_P1P
A23 USB_P1N
A24 Ground
A25 Ground
A26 P5V_USB_P1
A27 P5V_USB_P2
A28 Ground
A29 Ground
A30 USB_P2P
A31 USB_P2N
A32 Ground
PRSNT1_N 12V
12V 12V
12V RSVD
GND GND
JTAG2 SMCLK
JTAG3 SMDAT
JTAG4 GND
JTAG5 3_3V
3_3V JTAG1
3_3V 3_3VAUX
PERST_N WAKE_N
-------------- KEY --------------
GND RSVD
REFCLK + GND
REFCLK – PETP0
GND PETN0
PERP0 GND
PERN0 PRSNT2_N
GND GND
RSVD PETP1
GND PETN1
PERP1 GND
PERN1 GND
GND PETP2
GND PETN2
PERP2 GND
PERN2 GND
GND PETP3
GND PETN3
PERP3 GND
PERN3 RSVD
GND PRSNT2_N
RSVD GND
Pin # Signal Name
B1 FP_THERM_SENSOR
B2 P5V
B3 P5V
B4 P5V
B5 V_VIDEO_IN_USE
B6 Ground
B7 P5V_STBY
B8 Ground
B9 FP_FLT_LED_5VSB
B10 Ground
B11 LED_FP_SYS_FLT1_R_L
B12 FP_ID_SW_L
B13 LED_FP_ID_R_L
B14 SMB_IPMB_5VSB_DAT
B15 SMB_IPMB_5VSB_CLK
B16 Ground
B17 LED_NIC1_ACT_L
B18 LED_NIC1_LINK_R_L
B19 FP_PWR_BTN_L
B20 FP_PWR_LED_5VSB
B21 PV_HDD_LED_3V_A
B22 Ground
B23 Ground
B24 LED_NIC2_ACT_L
B25 LED_NIC2_LINK_R_L
B26 LED_HDD_FLT_R_L
B27 LED_HDD_ACT_RR_L
B28 LED_FP_PWR_R_L
B29 LED_FP_SYS_FLT2_R_L
B30 Ground
B31 Ground
B32 RST_PWRGD_PS
40
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL System Board Interconnects
Table 38. SAS/SATA Hard Drive Connector Pin-outs (J2C3, J2B1, J4C1, J4B1, J7C1)
Pin# Signal Description
SI Ground
S2 SAS#_TX_DP (# = 0…4)
S3 SAS#_TX_DN (# = 0…4)
S4 Ground
S5 SAS#_RX_DN (# = 0…4)
S6 SAS#_RX_DP (# = 0…4)
S7 Ground
P4 Ground
P5 Ground
P6 P3V3
P7 P5V
P8 P5V
P9 P5V
P10 Ground
P11 LED_SAS#_ACT_L (# =
0…4)
P12 Ground
P13 P12V
P14 P12V
P15 P12V
PTH0 Ground
PTY1 Ground
Revision – 1.00
Intel order number D31980-004
41
Peripheral and Hard Drive Sub-System Intel® Server System SR2500AL
5. Peripheral and Hard Drive Sub-System
The chassis can be configured to support several different hard drive and peripheral configurations. The peripheral/hard drive sub-system consists of a drive bay, supporting a slimline optical drive, hard drives, and flex bay; a mid-plane; and hot-swap backplane. This chapter describes the details for each sub-system component.
A B C
D
TP02108
A. Slimline IDE Optical Drive Bay
B. Optional 6th HDD Drive or Tape Drive Bay
C. System Control Panel
D. 3.5” Hard Drive Bays x5
Figure 26. Optional 6 th
Hard Drive (Front View)
5.1 Slimline Drive Bay
The chassis provides a slim-line drive bay that is designed to support a single slim-line IDE optical drive or USB Floppy Drive. A list of supported drives can be found in the Intel
®
Server
Board S5000PAL/S5000XAL Tested Hardware and OS List. Either drive type is mounted to a tool-less tray which allows for easy installation into and removal from the chassis. Once inserted into the chassis, the assembly locks into place. It is not hot-swappable. For removal, the system must be powered down, the chassis top cover removed and the locking latch disengaged.
42
AF000043
Figure 27. Slim-Line Optical Drive Assembly
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Peripheral and Hard Drive Sub-System
The IDE Optical drive assembly includes an interposer board which plugs into the back of the optical drive. The interposer board is a card-edge type card that eliminates the need for cable connections. As the drive assembly is inserted into the drive bay, the edge connector is blind mated to a slot connector on the backplane.
The interposer board has two connectors. The first connector is the industry standard 50-pin
IDE interface used by all slim-line optical devices. The second connector is the card edge used to connect directly to the hot-swap backplane board.
AF000042
Figure 28. 50-pin Connector to Slimline Optical Device
Table 39. J1L1 50-pin Connector to Slimline Optical Device
Revision – 1.00
PIN SIGNAL NAME
1 TP_LCH
2 TP_RCH
3 TP_GND
4 GND
5 RST_IDE_S_L
6 IDE_SDD8
7 IDE_SDD7
8 IDE_SDD9
9 IDE_SDD6
10 IDE_SDD10
11 IDE_SDD5
12 IDE_SDD11
13 IDE_SDD4
14 IDE_SDD12
15 IDE_SDD3
16 IDE_SDD13
17 IDE_SDD2
18 IDE_SDD14
19 IDE_SDD1
20 IDE_SDD15
21 IDE_SDD0
22 IDE_SDDREQ
23 GND
24 IDE_SDIOR_L
25 IDE_SDIOW_L
Intel order number D31980-004
PIN SIGNAL NAME
26 GND
27 IDE_SIORDY
28 IDE_SDDACK_L
29 IRQ_IDE_S
30 IDEIO16_L
31 IDE_SDA1
32 IDE_CBL_DET_S
33 IDE_SDA0
34 IDE_SDA2
35 IDE_SDCS0_L
36 IDE_SDCS1_L
37 IDE_SEC_HD_ACT_L
38 P5V
39 P5V
40 P5V
41 P5V
42 P5V
43 GND
44 GND
45 GND
46 GND
47 IDEP_ALE_H
48 GND
49 UNUSED
50 UNUSED
43
Peripheral and Hard Drive Sub-System Intel® Server System SR2500AL
The USB floppy drive assembly includes a USB cable which plugs into the back of the USB floppy drive and is then routed to the backplane’s 4-pin USB connector J2A1 (See Table 35.
USB Floppy Drive Connector (J2A1).
Note: The optional internal USB floppy drive accessory kit (product order code –
AXXUSBFLOPPY) includes a slim-line USB floppy drive, a USB cable, and mounting hardware to install the drive into either the slim-line drive bay or one of the hard drive bays.
5.2 Hard Drive Bays
The chassis can be configured to support up to 6 1 hot-swap 3.5” x1” SAS or SATA hard disk drives. Hard drives are mounted to hot-swap drive trays for easy insertion to or extraction from the drive bay.
5.2.1 Hot-swap Drive Trays
Each hard drive must be mounted to a hot-swap drive tray, making insertion and extraction of the drive from the chassis very simple. Each drive tray has its own dual purpose latching mechanism which is used to both insert/extract drives from the chassis and lock the tray in place. Each drive tray supports a light pipe providing a drive status indicator, located on the backplane, to be viewable from the front of the chassis.
E A
B
C
D
TP02106
Figure 29. Hard Drive Tray Assembly
A. Hard Drive
B. Drive Carrier
C. Side Rail
D. Mounting Screw
E. Hard Drive Connector
1
Default 5 Hard Drives + one optional 6
Th
Hard Drive using Flex Bay
44
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Peripheral and Hard Drive Sub-System
5.3 Optional Tape Drive or 6
th
Hard Drive Flex Bay
For system configurations that require either a Tape Drive or a 6 th
hard disk drive, a dual purpose drive bay is provided. By default this drive bay is covered by two face plates as shown in the following diagram. The drive bay is located next to the control panel.
TP02108
Figure 30. Optional 6 th
Hard Drive (Front View)
To configure a 6 th
hard drive, the lower face plate is removed and the 6 th
hard drive accessory kit is installed (product order code – ASR2500SIXDRV). This kit includes a backplane board insert, power cable, and drive carrier.
To install a 3.5” tape drive, both face plates are removed and the optional tape drive kit is installed (product order codes – ASR2500SATAPE or ADRTAPEKIT). Both tape drive kits include tape drive mounting tray and necessary cables.
Note: To remove the tape drive tray from the chassis, a spring latch located inside the chassis on the back right side of the carrier must be released to allow the drive tray to slide free. Do not attempt to pull out the drive tray without first releasing the spring latch. Doing so may damage the plastic faceplate.
TP02105
Figure 31. Optional Tape Drive (Front View)
Revision – 1.00
Intel order number D31980-004
45
Peripheral and Hard Drive Sub-System Intel® Server System SR2500AL
New to this generation of high density server platform is the concept of the mid-plane. The midplane is the interconnect between the server board and both the hot-swap backplane and control panel. It is also used to determine which hard drive technology is to be supported. Two different Mid-plane options are available for this platform 1) a passive mid-plane capable of supporting SATA ports from the server board or SAS using ports from an add-in card; 2) an active SAS / SAS RAID mid-plane. This section will describe the hard drive interface support of each of the mid-plane boards.
The passive mid-plane is used as an interconnect, routing drive control signals from either the on-board SATA ports of the baseboard or SAS/SATA ports from an add-in card to the hot-swap backplane. The hard drive controller signals are cabled to the mid-plane which then routes the signals to the hot-swap backplane through two edge connectors that plug directly into it. See
Table 22. Mid-plane-to-Backplane Card Edge Connector #1 Pin-out and Table 23. Mid-plane-to-
Backplane Card Edge Connector #2 Pin-out.
A
B
C
D
E
F
G
H
I
J
AF000047
Figure 32. Passive Mid-plane Board
A Power Connector
B Fan 6 Connector
C Fan 5 Connector
D SAS/SATA Connectors
E Bridge Board Connector
F Fan 4 Connector
G Fan 3 Connector
H Fan 1 Connector
I
J
Fan 2 Connector
Backplane Connector
46
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Peripheral and Hard Drive Sub-System
5.4.2 Active Mid-plane with Intel
®
SAS /SAS RAID Support
The active mid-plane is used to provide SAS / SAS RAID support. It has integrated on to it an
Intel IOP80333 IO processor and an LSI* LSLSAS1068 3Gb/s SAS controller. Together they provide support for up to six SAS drives in this chassis. By default, this mid-plane option provides software RAID levels 0, 1, and 10 utilizing Intel
®
Embedded RAID Technology II. With the installation of optional RAID enablement devices, the mid-plane can support hardware RAID levels 0, 1, 5, 10, and 50. The mid-plane attaches to the hot-swap backplane by two card edge connectors which eliminates the need for any hard drive cables. The following sub-sections describe the board level SAS / SAS RAID functionality.
C
A
B D
E
F
G
H
I
J
L
K
AF000046
Figure 33. Active Mid-plane with SAS / SAS RAID Support
A
B
RAID Activation Key
Connector
Power Connector
C Mini-DIMM Connector
D Fan 6 Connector
E
F
Fan 5 Connector
Bridge Board Connector
G Fan 4 Connector
H Fan 3 Connector
I
J
K
L
Fan 1 Connector
Fan 2 Connector
Battery
Backplane Connector
Revision – 1.00
Intel order number D31980-004
47
Peripheral and Hard Drive Sub-System Intel® Server System SR2500AL
Figure 34. Architecture Overview
5.4.2.2 x4 PCIe* Card Edge Interfaces
Two x4 PCIe* card edges are used to connect the active mid-plane to the hot-swap backplane.
See Table 22. Mid-plane-to-Backplane Card Edge Connector #1 Pin-out and Table 23. Midplane-to-Backplane Card Edge Connector #2 Pin-out for details. The use of card edge connectors to the back plane eliminates all hard drive cabling.
5.4.2.3 IOP80333 IO processor
The Intel 80333 IO processor is a multi-function device that integrates the Intel Xscale
®
core with intelligent peripherals and two PCIe* to PCI-X* bridges. It will be connected to the server board ’s x4 PCIe lane and serve as bridge for PCI-X 133MHz secondary bus. The IOP80333 also includes fully functional RAID support.
5.4.2.4 LSI* LSISAS1068 SAS Controller
The LSI* LSISAS1068 controller resides on the Channel A PCI-X bus of the IOP80333 supporting transfer rates of up to 3GB/s. It includes an Address Translation Unit (ATU) supporting transactions between PCI address space and 80333 address space. Address translation for the ATU is controlled through programmable registers accessible from both the
PCI interface and the Intel Xscale
®
core. The LSISAS1068 controller includes its own Flash
ROM and NVSRAM to support SAS only software RAID. Software RAID Levels supported include 0, 1, and 10.
5.4.2.5
The active mid-plane supports options to provide full hardware RAID support. Options required to enable hardware RAID support include an Intel
®
RAID Activation Key (product order code -
48
Optional Hardware RAID Support
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Peripheral and Hard Drive Sub-System
AXXRAK18E) and installation of a Mini-DIMM for Intel RAID Cache support. To protect from data loss during an unexpected power loss event, an Intel
®
RAID Smart Battery Backup module
(AXXRSBBU3) is also supported. Hardware RAID levels supported include 0, 1, 5, 10, and 50.
5.4.2.5.1 Intel® RAID Activation Key
The Intel
®
RAID Activation Key enables the full intelligent SAS Hardware RAID solution engineered around the Intel
®
80333 I/O Processor @ 500MHz. The activation key plugs directly in to a connector (J1A10) on the mid-plane board. With no RAID activation key installed, only
SAS Software RAID levels 0, 1, and 10 are supported.
5.4.2.5.2 Intel RAID Cache support
To further enable support for hardware RAID, the active mid-plane provides a 244-pin mini-
DIMM connector (J8C1), supporting a single registered ECC non-parity DDR2-400 MHz Mini-
DIMM to provide Intel RAID cache. Mini-DIMM capacities supported range from 128MB to 1GB.
Note: See the Intel
®
Server Board S5000PAL Tested Memory List for a list of Intel validated mini-DIMMs.
5.4.2.5.3 Intel
®
RAID Smart Battery Backup Module
With an Intel
®
RAID Smart Battery Backup module installed, data loss is prevented when data is still present in the RAID Cache Module and power is unexpectedly lost. Depending on the cache module capacity used, the battery backup unit can provide 48 to 72 hours of battery backup power to allow data stored in the RAID cache to be processed. A 2x10 connector (J9A2) is used to attach the battery backup unit to the mid-plane. See Table 24. Active Mid-plane SAS RAID
Battery Backup Connector Pin-out for details.
Revision – 1.00
Intel order number D31980-004
49
Peripheral and Hard Drive Sub-System Intel® Server System SR2500AL
5.5 Hot-Swap SAS/SATA Backplane
The chassis supports a multifunctional SAS/SATA backplane with the following features:
• Vitesse* VSC410 enclosure management controller o External non-volatile Flash ROM o Four C interfaces o Compliance with SCSI Accessed Fault Tolerant Enclosures (SAF-TE) specification o Compliance with Intelligent Platform Management Interface (IPMI)
• Five SAS/SATA compatible hot-swap hard drive connectors
• Designed to support an optional 6 th
hard drive, or power for an optional tape drive.
• Hard Drive Status and Fault LEDs for each hard drive connector
• Card edge connectors for most interconnects, including: o Mid-plane o Control o Slim-line IDE Optical Drive
• One 2x4-pin Power Connector
50
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
Peripheral and Hard Drive Sub-System
5.5.1 SAS/SATA Backplane Layout
The hot-swap backplane installs on the back side of the hot-swap drive bay inside the chassis.
Alignment features on the chassis and backplane assembly make for easy tool-less installation.
The following diagram shows the layout of components and connectors found on the board.
A
B
C
D
AF000045
Figure 35. Hot-swap SAS/SATA Backplane (Front Side View)
A Slim-line Optical Drive Connector
B Slim-line USB Floppy Connector
C Control Panel Connector
D SAS/SATA Hot Swap Connectors
Revision – 1.00
Intel order number D31980-004
51
Peripheral and Hard Drive Sub-System
A
B C
Intel® Server System SR2500AL
D
E
AF000044
Figure 36. Hot-swap SAS/SATA Backplane (Back Side View)
A Power Connector (for 6 th
Hard Drive or
Tape Drive)
B SAS/SATA Connector (for 6 th
Hard
Drive or SATA Tape Drive)
Notes: To prevent the backplane from flexing when installing or removing hard drives from the drive bay, make sure the mid-plane is securely fastened and the system top cover is in place.
Make sure all system boards, peripherals, and cables are detached from the backplane before removing the backplane from the system. Failure to detach components from the backplane before removal may result in component damage.
52
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Peripheral and Hard Drive Sub-System
5.5.2 SAS/SATA Backplane Functional Architecture
The figure below shows the functional blocks of the SAS/SATA backplane.
LM75
EEPROM
HBA Connector
SEEPROM
(FRU)
SEEPROM
Connector
I2C Bus0
I2C Bus1
I2C Bus2
Flash
Room
VSC410
LED
BUS SW
SAS_I2C
IPMB_I2C
I2C Connector
4P LCD Connector
SAS/SATA HDD0
Connector (29P)
SAS/SATA HDD3
Connector (29P)
SAS/SATA HDD4
Connector (29P)
SAS/SATA HDD5
Connector (7P)
(to 2U SAS/SATA
HDD Optional Board)
6th SAS/SATA
HDD Optional Board
SAS/SATA HDD1
Connector (29P)
SAS/SATA HDD2
Connector (29P)
SAS/SATA PWR, LED,
PRSNT Connector (7P)
(to 2U SAS/SATA
HDD Optional Board)
64P Connector X2
(from midplane)
Midplane
4P USB Connector
(for USB CD-ROM/FDD)
64P Front Panel Connector
(to Front Panel Board)
44P Internal
IDE Connector
(from baseboard)
64P Internal
IDE Connector
(to 64P CD-ROM
Interposer Board)
VRS RST
AF000040
Figure 37. SAS/SATA Backplane Functional Block Diagram
Revision – 1.00
Intel order number D31980-004
53
Peripheral and Hard Drive Sub-System Intel® Server System SR2500AL
5.5.2.1 Enclosure Management Controller
The backplane utilizes the features of the Vitesse* VSC410 to implement several enclosure management functions. The chip provides in-band SAF-TE and SES management and utilizes the four I
2
C interfaces listed below.
1. I2C bus 0 is connected to an EEPROM which stores configuration and FRU data
2. I2C bus 1 is connected to an LM75 temperature sensor
3. I2C bus 2 is connected to an IPMB bus from the server board.
4. I2C bus 3 is connected to the LSISAS1068 SAS controller.
5.5.2.2 Hard Drive Activity and Fault LEDs
The backplanes support an activity/fault LED for each of the hard drive connectors. The LED will illuminate green for activity or amber for a drive fault. The green activity LED is driven by the
SAS/SATA hard disk drive directly. The amber fault LED is driven by the VSC410* management controller whenever a fault condition is detected. When the drive is used in a
RAID configuration, the RAID controller will have control over the fault LED and it may exhibit different behavior.
Table 40. Hard Drive LED Function Definitions
Status LED Definition
54
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Peripheral and Hard Drive Sub-System
The activity LED functionality is controlled directly by the hard drives. This causes the LED to function differently between SAS and SATA drives. The expected operation is outlined below.
Power on with no drive activity
Table 41. Hard Drive Activity LED Functionality
SAS
Behavior
Ready LED stays on
Power on with drive activity
SATA
SAS
SATA
Ready LED stays off
Ready LED blinks off when processing a command
Ready LED blinks on when processing a command
Power on and drive spun down
SAS
SATA
Power on and drive spinning up
SAS
SATA
Ready LED stays off
Ready LED stays off
Ready LED blinks*
Ready LED stays off
The backplane is capable of supporting a 6 th
hot-swap SAS/SATA hard drive with the addition of an optionally installed backplane add-in board. The 6 th
drive add-in board assembly consists of a PCB with power and interface connectors, and a mounting bracket allowing for the add-in card to slide into a fitted cut out on the existing backplane.
Revision – 1.00
Intel order number D31980-004
55
Standard Control Panel
6. Standard Control Panel
Intel® Server System SR2500AL
The standard control panel supports several push buttons and status LEDs, along with USB and video ports to centralize system control, monitoring, and accessibility to within a common compact design.
The control panel assembly comes pre-assembled and is modular in design. The control panel assembly module slides into a slot on the front of the chassis and is blind mated with a slot connector on the backplane. It is not hot-swappable.
TP02110
Figure 38. Standard Control Panel Assembly Module
6.1 Control Panel Buttons
The standard control panel assembly houses several system control buttons. Each of their functions is listed in the table below.
A
B
C
D
Figure 39. Control Panel Buttons
TP02111
56
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Standard Control Panel
Table 42. Control Button and Intrusion Switch Functions
Reference
B
C
D
Feature Function
Sleep Button
ID Button
Toggles the system power on/off. This button also functions as a Sleep
Button if enabled by an ACPI-compliant operating system.
Toggles the front panel ID LED and the server board ID LED on/off. The server board ID LED is visible through the rear of the chassis and allows you to locate the server you’re working on from behind a rack of servers.
Reset Button Reboots and initializes the system.
NMI Button Pressing the recessed button with a paper clip or pin puts the server in a halt state for diagnostic purposes and allows you to issue a non-maskable interrupt. After issuing the interrupt, a memory download can be performed to determine the cause of the problem.
6.2 Control Panel LED Indicators
The control panel houses six LEDs, which are viewable with or without the front bezel to display the system’s operating state.
Power and
Sleep LED
NIC1 and NIC2
Activity LEDs
Hard Drive
Activity LED
System
Status LED
System
Identity LED
Figure 40. Control Panel LEDs
TP02112
Revision – 1.00
Intel order number D31980-004
57
Standard Control Panel Intel® Server System SR2500AL
The following table identifies each LED and describes their functionality.
Table 43. Control Panel LED Functions
LED
NIC1 / NIC2
Activity
Color State
Green On
Description
NIC
Power / Sleep
(on standby power)
System Status
(on standby power)
Disk Activity
System Identification
Green
Off
Green
On
Blink
1,4
Off
Legacy power on / ACPI S0 state
Sleep / ACPI S1 state
Power Off / ACPI S4 or S5 state Off
Green/Amber Alternating
Blink
Green On
Pre DC Power On – 15-20 second BMC
Initialization
Running / normal operation
Blink
1,2
Degraded
Amber On
Blink
1,2
Critical or non-recoverable condition.
Non-critical condition.
Off POST / system stop.
Random blink Provides an indicator for disk activity.
Blue On
No hard disk activity
Identify active via command or button.
Notes:
1. Blink rate is ~1 Hz with at 50% duty cycle.
2. The amber status takes precedence over the green status. When the amber LED is on or blinking, the green
LED is off.
3. Also off when the system is powered off (S4/S5) or in a sleep state (S1).
4. The power LED sleep indication is maintained on standby by the chipset. If the system is powered down without going through BIOS, the LED state in effect at the time of power off will be restored when the system is powered on until the BIOS clears it. If the system is not powered down normally, it is possible that the
Power LED will be blinking at the same time that the system status LED is off due to a failure or configuration change that prevents the BIOS from running.
The current limiting resistors for the power LED, the system fault LED, and the NIC LEDs are located on the server board.
58
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Standard Control Panel
6.2.1 Power / Sleep LED
Table 44. SSI Power LED Operation
State Power Mode
Power Off Non-ACPI
Power On Non-ACPI
S5 ACPI
S4
S3-S1
ACPI
ACPI
Off
On
LED Description
System power is off, and the BIOS has not initialized the chipset.
System power is on, but the BIOS has not yet initialized the chipset.
Off Mechanical is off, and the operating system has not saved any context to the hard disk.
Off Mechanical is off. The operating system has saved context to the hard disk.
Slow blink 1 DC power is still on. The operating system has saved context and gone into a level of low-power state.
Steady on System and the operating system are up and running. S0 ACPI
Notes:
1. Blink rate is ~ 1Hz with at 50% duty cycle.
6.2.2 System Status LED
Table 45. Control Panel LED Operation
Color
Off
Green/
Amber
State
N/A
Alternating
Blink
Criticality
Not ready
Not ready
Green Solid on
Green Blink
Ok
Degraded
Description
AC power off
Pre DC Power On – 15-20 second BMC Initialization when
AC is applied to the server. Control Panel buttons are disabled until BMC initialization is complete.
System booted and ready
System degraded
Unable to use all of the installed memory (more than one
DIMM installed).
Correctable errors over a threshold of 10 and migrating to a spare DIMM (memory sparing). This indicates that the user no longer has spared DIMMs indicating a redundancy lost condition. Corresponding DIMM LED should light up.
In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2).
Redundancy loss such as power-supply or fan. This does not apply to non-redundant sub-systems.
PCIe* link errors
CPU failure / disabled – if there are two processors and one of them fails
Fan alarm – Fan failure. Number of operational fans should be more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature and voltage
Amber Blink Non-critical
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans to cool the system not present or failed
In non-sparing and non-mirroring mode if the threshold of ten correctable errors is crossed within the window
Revision – 1.00
Intel order number D31980-004
59
Standard Control Panel
Amber Solid on Critical, nonrecoverable
Intel® Server System SR2500AL
Fatal alarm – system has failed or shutdown
DIMM failure when there is one DIMM present, no good memory present
Run-time memory uncorrectable error in non-redundant mode
IERR signal asserted
Processor 1 missing
Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed)
No power good – power fault
Processor configuration error (for instance, processor stepping mismatch)
6.2.2.1 System Status LED – BMC Initialization
When AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15-20 seconds to initialize. During this time, the system status LED will blink, alternating between amber and green, and the power button functionality of the control panel is disabled, preventing the server from powering up. Once BMC initialization has completed, the status LED will stop blinking and the power button functionality is restored and can be used to turn on the Server.
6.2.3 Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the onboard hard disk controllers. The Intel
®
Server Board S5000PAL also provides a header giving access to this
LED for add-in controllers.
6.2.4 System Identification LED
The blue system identification LED is used to help identify a system for servicing. This is especially useful when the system is installed when in a high density rack or cabinet that is populated with several similar systems.
The blue system ID LED can be illuminated using either of two mechanisms.
- By pressing the system ID button on the system control panel, the ID LED will display a solid blue color until the button is pressed again.
- By issuing the appropriate hex IPMI chassis identify value, the ID LED will either blink blue for 15 seconds and turn off or will blink indefinitely until the appropriate hex IPMI chassis identify value is issued to turn it off.
60
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
6.3 Control Panel Connectors
The control panel has two external I/O connectors:
• One USB port
• One VGA video port
The following tables provide the pin-outs for each connector.
Table 46. External USB Connectors (J1B1)
Pin # Description
1 PWR_FP_USB2
2 USB_DN2_FP_R
3 USB_DP2_FP_R
4 GND
5 GND
6 GND
7 GND
Table 47. Video Connector (J1A1)
Description Pin # Pin # Description
VGA_RED 1 9 GND
VGA_GREEN 2 10 GND
VGA_BLUE 3 11 Unused
Standard Control Panel
VGA_INUSE_L 7 15 VGA_DDCCLK
If a monitor is connected to the control panel video connector, the rear video port on the server board will be disabled and the control panel video will be enabled. The video source is the same for both connectors and is switched between the two, with the control panel having priority over the rear video. This provides for easy front accessibility to the server.
Revision – 1.00
Intel order number D31980-004
61
Standard Control Panel Intel® Server System SR2500AL
6.4 Internal Control Panel Interconnect
All control panel signals are directed through a single 64-pin card edge connector eliminating the need for any cables. When installed into the chassis control panel bay, the control panel card edge connector is blind mated with a slot connector on the backplane.
Standard Control
Panel PCB
AF000039
Figure 41. Standard Control Panel PCB
62
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
The following table defines the pin-out for the 64-pin edge connector.
Standard Control Panel
Table 48. 64-pin Control Panel Connector (J6B1)
PIN SIGNAL NAME
A1 GND
A2 VGA_VSYNC_FP_L
A3 GND
A4 VGA_HSYNC_FP_L
A5 GND
A6 VGA_BLUE_FP
A7 GND
A8 VGA_GREEN_FP
A9 GND
A10 VGA_RED_FP
A11 GND
A12 GND
A13 FP_RST_BTN_L
A14 GND
A15 NC_FP_CHASSIS_L
A16 GND
A17 BP_I2C_5V_SDA
A18 BP_I2C_5V_SCL
A19 GND
A20 FP_NMI_BTN_L
A21 GND
A22 USB_DP2_FP
A23 USB_DN2_FP
A24 GND
A25 GND
A26 PWR_FP_USB2
A27 PWR_FP_USB3
A28 GND
A29 GND
A30 USB_DP3_FP
A31 USB_DN3_FP
A32 GND
PIN SIGNAL NAME
B1 1_WIRE_BUS
B2 P5V
B3 P5V
B4 P5V
B5 VGA_INUSE_L
B6 GND
B7 P5V_STBY
B8 GND
B9 FAULT_LED_5VSB
B10 GND
B11 FP_SYS_FLT_LED1_R_L
B12 FP_ID_SW_L
B13 FP_ID_LED_R_L
B14 NC_IPMB_5VSB_SDA
B15 NC_IPMB_5VSB_SCL
B16 GND
B17 NIC1_ACT_LED_L
B18 NIC1_LINK_LED_R_L
B19 FP_PWR_BTN_L
B20 PWR_LED_5VSB
B21 HDD_LED_P3V3_A
B22 GND
B23 GND
B24 NIC2_ACT_LED_L
B25 NIC2_LINK_LED_R_L
B26 HDD_FAULT_LED_R_L
B27 HDD_LED_ACT_R_L
B28 FP_PWR_LED_R_L
B29 FP_SYS_FLT_LED2_R_L
B30 GND
B31 GND
B32 NC_RST_P6_PWRGOOD
Revision – 1.00
Intel order number D31980-004
63
Intel® Local Control Panel
7. Intel
®
Local Control Panel
Intel® Server System SR2500AL
The Intel
®
Local Control Panel utilizes a combination of control buttons, LEDs, and LCD display to provide system accessibility, monitoring, and control functions. The pre-assembled module slides into a slot on the front of the chassis where a card edge connector is blind mated to a matching slot edge connector on the backplane eliminating any cable attachments. The Intel
®
Local Control Panel module is designed so that it can be adjusted for use with or without an outer front bezel.
TP02113
Figure 42. Intel
®
Local Control Panel Assembly Module
The following diagram provides an overview of the control panel features.
A B
C
D
E
F
O N M L K J I H G
TP02099
Figure 43. Intel
®
Local Control Panel Overview
A LCD Display
B LCD Menu Control Button – Up
I
J
System Status LED
NIC 2 Activity LED
C LCD Menu Control Button – Down K
D LCD Menu Control Button – Previous Option L
E LCD Menu Control Button – Previous Page
F ID LED
M
N
NIC 1 Activity LED
Hard Drive Activity LED
System Reset Button
USB 2.0 Port
G Power LED
H System Power Button
O
P
NMI Button (Tool Required)
USB 2.0 Port
64
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Intel® Local Control Panel
The following table identifies each LED and describes their functionality.
Table 49. Control Panel LED Functions
LED
NIC1 / NIC2
Activity
Color State
Green On
Description
NIC
Power / Sleep
(on standby power)
System Status
(on standby power)
Disk Activity
System Identification
Green On
Blink
1,4
Legacy power on / ACPI S0 state
Sleep / ACPI S1 state
Off Off
Green/Amber Alternating
Blink
Green On
Power Off / ACPI S4 or S5 state
Pre DC Power On – 15-20 second BMC
Initialization
Running / normal operation
Blink
1,2
Degraded
Amber On
Blink
1,2
Off
Critical or non-recoverable condition.
Non-critical condition.
Off POST / system stop.
Green Random blink Provides an indicator for disk activity.
3
Off Off No hard disk activity
Blue On Identify active via command or button.
Notes:
1. Blink rate is ~1 Hz with at 50% duty cycle.
2. The amber status takes precedence over the green status. When the amber LED is on or blinking, the green
LED is off.
3. Also off when the system is powered off (S4/S5) or in a sleep state (S1).
4. The power LED sleep indication is maintained on standby by the chipset. If the system is powered down without going through BIOS, the LED state in effect at the time of power off will be restored when the system is powered on until the BIOS clears it. If the system is not powered down normally, it is possible that the
Power LED will be blinking at the same time that the system status LED is off due to a failure or configuration change that prevents the BIOS from running.
The current limiting resistors for the power LED, the system fault LED, and the NIC LEDs are located on the Intel
®
Server Board S5000PAL.
Revision – 1.00
Intel order number D31980-004
65
Intel® Local Control Panel Intel® Server System SR2500AL
7.1.1 Power / Sleep LED
Table 50. SSI Power LED Operation
State Power Mode
Power Off Non-ACPI
Power On Non-ACPI
S5 ACPI
S4
S3-S1
S0
ACPI
ACPI
Off
On
LED Description
System power is off, and the BIOS has not initialized the chipset.
System power is on, but the BIOS has not yet initialized the chipset.
Off Mechanical is off, and the operating system has not saved any context to the hard disk.
Off Mechanical is off. The operating system has saved context to the hard disk.
Slow blink 1 DC power is still on. The operating system has saved context and gone into a level of low-power state.
Steady on System and the operating system are up and running. ACPI
Notes:
1. Blink rate is ~ 1Hz with at 50% duty cycle.
7.1.2 System Status LED
Table 51. Control Panel LED Operation
Color
Off
Green/
Amber
State
N/A
Alternating
Blink
Criticality
Not ready
Not ready
Green Solid on
Green Blink
Ok
Degraded
Description
AC power off
Pre DC Power On – 15-20 second BMC Initialization when
AC is applied to the server. Control Panel buttons are disabled until BMC initialization is complete.
System booted and ready
System degraded
Unable to use all of the installed memory (more than one
DIMM installed).
Correctable errors over a threshold of 10 and migrating to a spare DIMM (memory sparing). This indicates that the user no longer has spared DIMMs indicating a redundancy lost condition. Corresponding DIMM LED should light up.
In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2).
Redundancy loss such as power-supply or fan. This does not apply to non-redundant sub-systems.
PCIe link errors
CPU failure / disabled – if there are two processors and one of them fails
Fan alarm – Fan failure. Number of operational fans should be more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature and voltage
Amber Blink Non-critical
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans to cool the system not present or failed
In non-sparing and non-mirroring mode if the threshold of ten correctable errors is crossed within the window
66
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
Amber Solid on Critical, nonrecoverable
Intel® Local Control Panel
Fatal alarm – system has failed or shutdown
DIMM failure when there is one DIMM present, no good memory present
Run-time memory uncorrectable error in non-redundant mode
IERR signal asserted
Processor 1 missing
Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed)
No power good – power fault
Processor configuration error (for instance, processor stepping mismatch)
7.1.2.1 System Status LED – BMC Initialization
When AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15-20 seconds to initialize. During this time, the system status LED will blink, alternating between amber and green, and the power button functionality of the control panel is disabled, preventing the server from powering up. Once BMC initialization has completed, the status LED will stop blinking and the power button functionality is restored and can be used to turn on the server.
7.1.3 Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the onboard hard disk controllers. The Intel
®
Server Board S5000PAL also provides a header giving access to this
LED for add-in controllers.
7.1.4 System Identification LED
The blue system identification LED is used to help identify a system for servicing. This is especially useful when the system is installed when in a high density rack or cabinet that is populated with several similar systems.
The blue system ID LED can be illuminated using either of two mechanisms.
- By pressing the system ID button on the system control panel, the ID LED will display a solid blue color until the button is pressed again.
- By issuing the appropriate hex IPMI chassis identify value, the ID LED will either blink blue for 15 seconds and turn off or will blink indefinitely until the appropriate hex IPMI chassis identify value is issued to turn it off.
Revision – 1.00
Intel order number D31980-004
67
Intel® Local Control Panel Intel® Server System SR2500AL
7.2 Intel
®
Local Control Panel Interconnects
The Intel
®
Local Control Panel module includes the control panel interface board and an interposer board. Connectors on the control panel interface board are cabled to matching connectors on the interposer board. When the pre-assembled control panel module is installed into the chassis, a card edge connector on the interposer card is blind mated with a slot edge connector on the backplane. This section will define the pin-out for each connector and header found on both the control panel interface board and interposer board.
• A 64-pin card edge connector on the interposer board is used to route signals to/from the backplane to the control panel interface board. The backplane is used as a conduit for communication to the server board.
•
Signals from the card edge connector are routed to control panel interface board through matching 50-pin connectors on the interposer board and control panel interface board.
The 50-pin connectors are attached using a small 50-pin flat cable.
• USB signals from the card edge connector are routed to the control panel interface board through matching 10-pin connectors on the interposer board and control panel interface board. The 10-pin connectors are attached using a small 10-pin round cable.
• A 4-pin IPMI header (not used).
• A 4-pin NMI/Temp Sensor header.
The following tables provide the pin-outs for each connector.
68
Table 52. 50-pin Control Panel Connector
PIN SIGNAL NAME
A1 GND
A2 VGA_VSYNC_FP_L
A3 GND
A4 VGA_HSYNC_FP_L
A5 GND
A6 VGA_BLUE_FP
A7 GND
A8 VGA_GREEN_FP
A9 GND
A10 VGA_RED_FP
A11 GND
A12 GND
A13 FP_RST_BTN_L
A14 GND
A15 NC_FP_CHASSIS_L
A16 GND
A17 BP_I2C_5V_SDA
A18 BP_I2C_5V_SCL
A19 GND
A20 FP_NMI_BTN_L
A21 GND
A22 USB_DP2_FP
A23 USB_DN2_FP
A24 GND
A25 GND
PIN SIGNAL NAME
B1 1_WIRE_BUS
B2 P5V
B3 P5V
B4 P5V
B5 VGA_INUSE_L
B6 GND
B7 P5V_STBY
B8 GND
B9 FAULT_LED_5VSB
B10 GND
B11 FP_SYS_FLT_LED1_R_L
B12 FP_ID_SW_L
B13 FP_ID_LED_R_L
B14 NC_IPMB_5VSB_SDA
B15 NC_IPMB_5VSB_SCL
B16 GND
B17 NIC1_ACT_LED_L
B18 NIC1_LINK_LED_R_L
B19 FP_PWR_BTN_L
B20 PWR_LED_5VSB
B21 HDD_LED_P3V3_A
B22 GND
B23 GND
B24 NIC2_ACT_LED_L
B25 NIC2_LINK_LED_R_L
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
PIN SIGNAL NAME
A26 PWR_FP_USB2
A27 PWR_FP_USB3
A28 GND
A29 GND
A30 USB_DP3_FP
A31 USB_DN3_FP
A32 GND
Intel® Local Control Panel
PIN SIGNAL NAME
B26 HDD_FAULT_LED_R_L
B27 HDD_LED_ACT_R_L
B28 FP_PWR_LED_R_L
B29 FP_SYS_FLT_LED2_R_L
B30 GND
B31 GND
B32 NC_RST_P6_PWRGOOD
Table 53. Internal USB Header
Pin # Description
1 PWR_FP_USB2
2 PWR_FP_USB3
3 USB_DP2_FP
4 USB_DN2_FP
5 USB_DP3_FP
6 USB_DN3_FP
7 GND
8 GND
9 TP_USB0_P9
10 TP_USB0_P10
Revision – 1.00
Intel order number D31980-004
69
PCI Riser Cards and Assembly
8. PCI Riser Cards and Assembly
Intel® Server System SR2500AL
The chassis supports different riser card options depending on the add-in card configuration desired. The riser assembly for the chassis is tool-less. Stand-offs on the bracket allow the riser cards to slide onto the assembly where a latching mechanism than holds each riser in place.
Holding down the latch releases the risers for easy removal.
When re-inserting the riser assembly into the chassis, tabs on the back of the assembly should be aligned with slots on the back edge of the chassis. The tabs fit into the slots securing the riser assembly to the chassis when the top cover is in place.
The riser assembly provides two extraction levers to assist with riser assembly removal from the riser slots.
AF000038
Figure 44. Low Profile PCIe* Riser
70
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL PCI Riser Cards and Assembly
8.1 Riser Card Options
The Intel
®
Server Board S5000PAL has two riser slots capable of supporting riser cards for both
1U and 2U system configurations. Because of board placement resulting in different pin orientations, and expanded technology support associated with the full-height riser, the riser slots are not the same and require different riser cards.
The low profile riser slot (J5B1) utilizes a 98-pin connector. It is capable of supporting up to two low profile PCIe* add-in cards. The x8 PCIe bus can support bus speeds of up to 20Gb/S. The following table provides the supported bus throughput for the given riser card used and the number of add-in cards installed.
Low Profile Riser 1 add-in card 2 add-in cards
2U X4 X4
Note: There are no population rules for installing a single low profile add-in card in the 2U low profile riser card; a single add in card can be installed in either PCI Express* slot. While each slot can accommodate a x8 card, each slot will only support x4 bus speeds.
The full height riser slot (J4F1) implements Intel
®
Adaptive Slot Technology. This 280-pin connector is capable of supporting riser cards that meet either the PCI-X* or PCI Express* technology specifications. The following tables show the maximum bus speed supported with different add-in card populations.
Full Height Riser
PCI-X “Passive” (Product
Order Code –
ADRPCIXRIS)
1 add-in card
2U – 3 add-in card slots Up to 100MHz in top PCI slot
2 add-in cards
Up to 100MHz using top and middle slots
3 add-in cards
66MHz
Note: For the 2U PCI-X* (passive) riser card, add-in cards should be installed starting with the top slot first, followed by the middle, and then the bottom. Any add-in card populated in the bottom PCI slot will cause the bus to operate at 66MHz.
Full Height Riser
PCI-X “Active” (Product
Order Code –
ADRACTRIS)
2U
1 add-in card
Up to 133MHz
2 add-in cards
Up to 133MHz
3 add-in cards
Up to 133MHz
Note: Each PCI slot on the 2U PCI-X* (active) riser card operates on an independent PCI bus.
Using an add-in card that operates below 133MHz will not affect the bus speed of the other PCI slots.
Revision – 1.00
Intel order number D31980-004
71
PCI Riser Cards and Assembly
Full Height Riser
PCI Express* (Product
Order Code –
ASR2500FHR)
1 add-in card
2U – 3 add-in card slots Single PCIe* x4 in either slot or x8 in middle slot
Or
PCI-X* – Up to 133MHz in bottom slot
Intel® Server System SR2500AL
2 add-in cards 3 add-in cards
Single PCIe – x4 in either slot or x8 in middle slot and PCI-
X – Up to 133MHz
Or
Dual PCIe – x4
Dual PCIe – x4
And
PCI-X – Up to 133MHz
8.2 PCI Riser Card Mechanical Drawings
Ø 6.00
[0.236]
5.00 [0.197]
Ø 3.50
[0.138]
R2.00
[0.079]
Detail A
Scale 2.000
Well Buying
DMI-02D-30-3
Pad
10.16 [0.400]
See Detail A
2X 67.75 [2.667]
66.17 [2.605]
46.98 [1.850]
41.98 [1.653]
24.32 [0.958]
23.32 [0.918]
19.32 [0.761]
10.90 [0.429]
8.40 [0.331]
2X R1.00
[0.039]
1.90 [0.075]
39.15 [1.541]
2X Molex
SD-87715-013
6012A0100101
74.75 [2.943]
64.25 [2.530]
54.25 [2.136]
35.32 [1.391]
33.16 [1.306]
27.32 [1.076]
17.24 [0.679]
12.84 [0.506]
8.40 [0.0331]
0.00 [0.000]
12.15 [0.478]
Side 2
Ground Pad
TP02322
Figure 45. Low Profile Passive PCI Express* Riser Card
72
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
Ø 8.26
[0.325]
Both Side
Ground Pad
3.50 [0.138]
Ø 3.50 [0.138]
Detail A
Scale 2.000
5.00
[0.197]
Ø 6.00
[0.236]
R2.00
[0.079]
PCI Riser Cards and Assembly
4X Side 1
No Component
4X 2.50 [0.098]
20˚
1.60
[0.063]
74.75 [2.943]
70.43 [2.773]
67.67 [2.664]
58.18 [2.291]
50.11 [1.973]
38.29 [1.508]
35.40 [1.394]
32.20 [1.268]
27.40 [1.079]
2X 17.15 [0.675]
8.40 [0.331]
3.50 [0.138]
0.00 [0.000]
0.5 X 45˚ 6 Pcs
10.76
[0.424]
Side 2 Ground Pad
See Detail B
Side 2
No Component
8.40 [0.331]
12.15 [0.478]
66.05 [2.600]
1.90 [0.075]
1.90 [0.075]
66.00 [2.598]
Detail B
Scale 2.000
5.00
[0.197]
Notes:
1. PCB tolerance:
A: 62 mil (1.58 mm) ± 7 mil
B: 93 mil (2.36 mm) ± 9 mil
C: 98 mil (2.49 mm) ± 9 mil
2. If there is needed:
sheet 1: Board profile and mounting hole
2: Pin location
3: Constrain area on both sides
3. No indicated radii should be 2.00 mm
Figure 46. Full Height PCI Express* Riser Card
See Detail A
5X R1.00 [0.039]
68.90 [2.713]
2X 67.78 [2.668]
2X 47.46 [1.868]
2X R1.27 [0.050]
6.25 [0.246]
TP02320
Revision – 1.00
Intel order number D31980-004
73
PCI Riser Cards and Assembly
Ø 8.26
[0.325]
Both Side
Ground Pad
3.50 [0.138]
5.00
[0.197]
Ø 6.00
[0.236]
R2.00
[0.079]
Ø 3.50 [0.138]
Detail A
Scale 2.000
See Detail A
74.75 [2.943]
72.84 [2.868]
67.67 [2.664]
52.52 [2.068]
1.60
[0.063]
35.40 [1.394]
32.20 [1.268]
27.40 [1.079]
2X 17.15 [0.675]
8.40 [0.331]
0.00 [0.000]
0.5 X 45˚ 6 Pcs
10.76
[0.424]
Intel® Server System SR2500AL
Side 2 Ground Pad
See Detail B
Side 2
No Component
1.90 [0.075]
66.05 [2.600]
8.40
[0.331]
12.15 [0.478]
1.90 [0.075]
66.00 [2.598]
5X R1.00 [0.039]
68.90 [2.713]
58.18 [2.291]
38.29 [1.508]
2X R1.27 [0.050]
6.25 [0.246]
3.50 [0.138]
Detail B
Scale 2.000
5.00
[0.197]
Notes:
1. PCB tolerance:
A: 62 mil (1.58 mm) ± 7 mil
B: 93 mil (2.36 mm) ± 9 mil
C: 98 mil (2.49 mm) ± 9 mil
2. If there is needed:
sheet 1: Board profile and mounting hole
2: Pin location
3: Constrain area on both sides
3. No indicated radii should be 2.00 mm
Figure 47. Full Height Passive PCI-X* Riser Card
TP02321
74
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL PCI Riser Cards and Assembly
See Detail A
74.75 [2.943]
72.84 [2.868]
67.67 [2.664]
58.18 [2.291]
52.52 [2.068]
38.39 [1.508]
35.40 [1.394]
32.20 [1.268]
27.40 [1.079]
17.15 [0.675]
2X 8.40 [0.331]
3.50 [0.138]
0.00 [0.000]
0.5 X 45˚ 6 Pcs
1.90 [0.075]
66.05 [2.600]
Side 2 Ground Pad
See Detail B
8.40
[0.331]
12.15 [0.478]
1.90 [0.075]
66.00 [2.598]
R1.00 [0.039]
70.50 [2.776]
68.90 [2.713]
56.63 [2.230]
2X R1.27
[0.050]
8.40 [0.331]
6.25 [0.246]
Notes:
1. PCB tolerance:
A: 62 mil (1.58 mm) ± 7 mil
B: 93 mil (2.36 mm) ± 9 mil
C: 98 mil (2.49 mm) ± 9 mil
2. If there is needed:
sheet 1: Board profile and mounting hole
2: Pin location
3: Constrain area on both sides
3. No indicated radii should be 2.00 mm
Ø 8.26
[0.325]
3.50 [0.138]
Detail A
Scale 2.000
5.00
[0.197]
Ø 6.00
[0.236]
10.76
[0.424]
2X R2.00
[0.079]
Detail B
Scale 2.000
5.00
[0.197]
1.60
[0.063]
TP02323
Figure 48. Full Height Active PCI-X* Riser Card
Revision – 1.00
Intel order number D31980-004
75
Supported Intel® Server Boards Intel® Server System SR2500AL
®
Server Boards
The chassis is mechanically and functionally designed to support the Intel
®
Server Board
S5000PAL and Intel
®
Server Board S5000XAL. The following sections provide an overview of the server board feature sets. The Technical Product Specification for the server board should be referenced for more detailed information.
9.1 Intel
®
Server Board S5000PAL / S5000XAL Feature Set
The Intel
®
Server Board S5000PAL and Intel
®
Server Board S5000XAL are monolithic printed circuit boards with features that were designed to support the high-density 1U and 2U server markets.
Feature
Processors
Description
771-pin LGA sockets supporting 1 or 2 Dual-Core Intel
®
Xeon
®
processors 5000 sequence, with system bus speeds of 667 MHz, 1066 MHz, or 1333 MHz
Memory 8 Keyed DIMM slots supporting fully buffered DIMM technology (FBDIMM) memory. 240-pin
DDR2-533 and DDR2-677 FBDIMMs must be used.
Chipset Intel
®
5000 Chipset Family which includes the following components:
Intel ® 5000P Memory Controller Hub or Intel ® 5000X Memory Controller Hub
On-board
Connectors/Headers
Add-in PCI, PCI-X*, PCI
Express* Cards
On-board Video
On-board Hard Drive
Controller
Intel
®
6321ESB I/O Controller Hub1
Note: Intel will only make available an OEM SKU of this server board using the Intel
®
5000X
Memory Controller Hub.
External connections:
Stacked PS/2* ports for keyboard and mouse
RJ45 Serial B port
Two RJ45 NIC connectors for 10/100/1000 Mb connections
Two USB 2.0 ports
Video Connector
Internal connectors/headers:
One USB port header, capable of providing two USB 2.0 ports
One DH10 Serial A header
Six SATA ports via the ESB-2 supporting 3Gb/s and integrated SW RAID 0/1/10 support
One 44pin (power + I/O) ATA/100 connector for optical drive support
One Intel ®
Remote Management Module (Intel
®
RMM) connector (Intel
®
RMM use is optional)
One Intel ®
I/O Expansion Module Connector supporting:
Dual GB NIC Intel ®
I/O Expansion Module (Optional)
External SAS Intel ® I/O Expansion Module (Optional)
Infiniband* I/O Expansion Module (Optional)
SSI-compliant 24-pin control panel header
SSI-compliant 24-pin main power connector, supporting the ATX-12V standard on the first
20 pins
8-Pin +12V Processor Power Connector
One low profile riser slot supporting 1U or 2U PCIe* riser cards
One full height riser slot supporting 1U or 2U PCI-X* and PCIe* riser cards
ATI* ES1000 video controller with 16MB DDR SDRAM
Six ESB-2 3Gb/s SATA ports.
Intel ® Embedded Server RAID Technology II with SW RAID levels 0/1/10.
LAN
System Fans
Optional support for SW RAID 5 with activation key.2
Two 10/100/1000 Intel ® 82563EB PHYs supporting Intel ® I/O Acceleration Technology
Six 4-pin Fan Headers supporting two processor fans, and four system fans
1
For the remainder of this document, the Intel
®
6321ESB I/O Controller Hub may be refferred to as ESB-2.
2
Onboard SATA SW RAID 5 support provided as a post-launch product feature.
76
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
System Management Support for Intel
®
System Management Software
A B C D E F G H I
Supported Intel® Server Boards
PP
FF
EE
DD
CC
BB
AA
OO
NN
LL
MM
KK
JJ
II
HH
GG
Z
M
N
J
K
L
O
P
Q
Y X W V U T S R
Figure 49. Intel
®
Server Board S5000PAL
TP02071
Revision – 1.00
Intel order number D31980-004
77
Supported Intel® Server Boards
Description
A BIOS Bank Select Jumper
B Intel
®
6321ESB I/O Controller Hub
C IO Module Option Connector
D POST Code Diagnostic LEDs
E Intel
®
Adaptive Slot – Full Height
F PCI Express* Riser Slot – Low Profile
G System Identification LED - Blue
H External IO Connectors
I Status LED – Green / Amber
J Serial ‘B’ Port Configuration Jumper
K System Fan #4 Header
L System Fan #3 Header
M FBDIMM Slots
N Intel
Intel
®
®
5000P Memory Controller Hub (MCH) or
5000X Memory Controller Hub (MCH)
O CPU #1 Connector
P CPU #2 Connector
Q CPU #1 Fan Header
R Voltage Regulator Heat Sink
S CPU #2 Fan Header
T Bridge Board Connector
U ATA-100 Optical Drive Connector (Power+IO)
Intel® Server System SR2500AL
V
Description
System Fan #2 Header
W CPU Power Connector
X
Y
Main Power Connector
Battery
Z Power Supply Management Connector
AA Dual Port USB 2.0 Header
BB System Fan #1 Header
CC SSI 24-pin Control Panel Header
DD SATA 0
EE SATA 1
FF SATA 2
GG SATA 3
HH SATA 4
JJ SATA SW RAID 5 Activation Key Connector
KK Intel
®
Remote Management Module (RMM)
Connector
LL System Recovery Jumper Block
MM Chassis Intrusion Switch Header
NN 3-pin IPMB Header
OO Intel
®
Local Control Panel Header
PP Serial ‘A’ Header
Intel
®
RMM NIC Connector
Figure 50. Intel
®
Server Board S5000PAL Components
The server system supports one or two Dual-Core Intel
®
Xeon
®
processors 5000 sequence, with system bus speeds of 667 MHz, 1066 MHz, and 1333 MHz, and core frequencies starting at
2.67 GHz. Previous generations of the Intel
®
Xeon
®
processor are not supported on this server board.
Note: Only Dual-Core Intel
®
Xeon
®
processors 5000 sequence, that support system bus speeds of 667 MHz, 1066 MHz, and1333 MHz are supported on this server board. See the following table for a list of supported processors.
78
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Supported Intel® Server Boards
Dual-Core Intel
®
Xeon
®
processors 5000 sequence will encompass the following:
Processor Family
Intel
®
Xeon
®
Intel
®
Xeon
®
Dual-Core Intel
®
Xeon
®
Processor 5030
Dual-Core Intel
®
Xeon
®
Processor 5050
Dual-Core Intel
®
Xeon
®
Dual-Core Intel
®
Xeon
®
Processor 5060
Processor 5063
Dual-Core Intel
®
Xeon
®
Processor 5080
Dual-Core Intel
®
Xeon
®
Processor 51xx
Table 54. Processor Support Matrix
System Bus
Speed
Core Frequency Cache
667 MHz
667 MHz
1066 MHz
1066 MHz
1066 MHz
1333/1066 MHz
2.67 GHz
3.0 GHz
3.2 GHz
3.2 GHz
3.73 GHz
TBD
2x 2 MB
2x 2 MB
2x 2 MB
2x 2 MB
2x 2 MB
TBD
Watts
95
95
130
95
130
TBD
Support
No
No
Yes
Yes
Yes
Yes
Yes
Yes
9.1.1.1 Processor Population Rules
When two processors are installed, both must be of identical revision, core voltage, and bus/core speed. When only one processor is installed, it must be in the socket labeled CPU1.
The other socket must be empty.
The system is designed to provide up to 130A of current per processor. Processors with higher current requirements are not supported.
No terminator is required in the second processor socket when using a single processor configuration.
9.1.1.2 Common Enabling Kit (CEK) Design Support
The server system complies with Intel’s Common Enabling Kit (CEK) processor mounting and heat sink retention solution. The server board ships with a CEK spring snapped onto the underside of the server board, beneath each processor socket. The heat sink attaches to the
CEK, over the top of the processor and the thermal interface material (TIM). See the figure below for the stacking order of the chassis, CEK spring, server board, TIM, and heat sink.
The CEK spring is removable, allowing for the use of non-Intel heat sink retention solutions.
Revision – 1.00
Intel order number D31980-004
79
Supported Intel® Server Boards
Heatsink assembly
Thermal interface material (TIM)
Server board
CEK spring
Chassis
Figure 51. CEK Processor Mounting
Intel® Server System SR2500AL
80
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Environmental and Regulatory Specifications
10. Environmental and Regulatory Specifications
10.1 System Level Environmental Limits
The table below defines the system level operating and non-operating environmental limits
Table 55. System Environmental Limits Summary
Parameter Limits
Operating Temperature +10
°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating -40
°C to +70°C
Temperature
Non-Operating Humidity 90%, non-condensing @ 28
°C
Acoustic noise
Shock, operating
Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 +/- 2 degrees C)
Half sine, 2 g peak, 11 mSec
Shock, unpackaged
Shock, packaged
Trapezoidal, 25 g, velocity change 136 inches/sec
Vibration, unpackaged
Shock, operating
Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs)
5 Hz to 500 Hz, 2.20 g RMS random
Half sine, 2 g peak, 11 mSec
ESD
System Cooling
Requirement in BTU/Hr
+/-15kV except I/O port +/-8KV per Intel Environmental test specification
1826 BTU/hour
10.2 Product Regulatory Compliance
10.2.1 Product Safety Compliance
The Intel
®
Server Chassis SR2500 complies with the following safety requirements:
• UL60950 – CSA 60950(USA / Canada)
• EN60950 (Europe)
• CB Certificate & Report, IEC60950 (report to include all country national deviations)
• GS License (Germany)
• Belarus License (Belarus)
• Ukraine License (Ukraine)
• CE - Low Voltage Directive 73/23/EEE (Europe)
• IRAM Certification (Argentina)
• GB4943- CNCA Certification (China)
Revision – 1.00
Intel order number D31980-004
81
Environmental and Regulatory Specifications Intel® Server System SR2500AL
10.2.2 Product EMC Compliance
The Intel
®
Server Chassis SR2500 has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed a compatible Intel host system.
For information on compatible host system(s) refer to Intel’s Server Builder website or contact your local Intel representative.
• FCC (Class A Verification) – Radiated & Conducted Emissions (USA)
• CISPR 22 – Emissions (International)
• EN55022 - Emissions (Europe)
• EN55024 - Immunity (Europe)
• EN61000-3-2 - Harmonics (Europe)
• EN61000-3-3 - Voltage Flicker (Europe)
• CE – EMC Directive 89/336/EEC (Europe)
• VCCI Emissions (Japan)
• AS/NZS 3548 Emissions (Australia / New Zealand)
• BSMI CNS13438 Emissions (Taiwan)
• Belarus License (Belarus)
• Ukraine License (Ukraine)
• RRL MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea)
• GB 9254 - CNCA Certification (China)
• GB 17625 - (Harmonics) CNCA Certification (China)
82
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Environmental and Regulatory Specifications
10.2.3 Product Regulatory Compliance Markings
This product is provided with the following product certification markings.
Regulatory Compliance Region Marking cULus Listing Marks USA/Canada
GS Mark Germany
CE Mark Europe
FCC Marking (Class A) USA
EMC Marking (Class A)
C-Tick Mark
Canada
Australia / New Zealand
VCCI Marking (Class A) Japan
BSMI Certification
Number & Class A
Warning
Taiwan
RRL MIC Mark
China Compulsory
Certification Mark
Korea
China
Revision – 1.00
Intel order number D31980-004
83
Environmental and Regulatory Specifications
10.3 Electromagnetic Compatibility Notices
Intel® Server System SR2500AL
10.3.1 USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions related to the EMC performance of this product, contact:
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124
1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product.
Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC
Class B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception.
84
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Environmental and Regulatory Specifications
10.3.2 FCC Verification Statement
Product Type: Intel
®
Server Chassis SR2500; Intel
®
Server Board S5000PAL
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions related to the EMC performance of this product, contact:
Intel Corporation
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124-6497
Phone: 1 (800)-INTEL4U or 1 (800) 628-8686
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur:
“Appareils Numériques”, NMB-003 édictée par le Ministre Canadian des Communications.
(English translation of the notice above) This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Canadian Department of
Communications.
10.3.4 Europe (CE Declaration of Conformity)
This product has been tested in accordance too, and complies with the Low Voltage Directive
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.
10.3.5 Japan EMC Compatibility
Electromagnetic Compatibility Notices (International)
English translation of the notice above:
This is a Class A product based on the standard of the Voluntary Control Council For
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
Revision – 1.00
Intel order number D31980-004
85
Environmental and Regulatory Specifications Intel® Server System SR2500AL
The BSMI Certification number and the following warning is located on the product safety label which is located on the bottom side (pedestal orientation) or side (rack mount configuration).
10.3.7 Korean RRL Compliance
English translation of the notice above:
1. Type of Equipment (Model Name): On License and Product
2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative
3. Name of Certification Recipient: Intel Corporation
4. Date of Manufacturer: Refer to date code on product
5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product
The CCC Certification Marking and EMC warning is located on the outside rear area of the product.
86
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Environmental and Regulatory Specifications
10.4 Replacing the Back up Battery
The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong.
Contact your customer service representative or dealer for a list of approved devices.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Discard used batteries according to manufacturer’s instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
Revision – 1.00
Intel order number D31980-004
87
Environmental and Regulatory Specifications Intel® Server System SR2500AL
10.5 Serviceability and Availability
The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of the system problem. To meet this goal, the system enclosure and hardware have been designed to minimize the MTTR.
Following are the maximum times that a trained field service technician should take to perform the listed system maintenance procedures, after diagnosis of the system and having identified the failed component.
Activity
Remove cover
Remove and replace hard disk drive
Remove and replace power supply module
Remove and replace system fan (non-hot swappable)
Remove and replace system fan (hot swappable)
Remove and replace backplane board
Remove and replace midplane board
Remove and replace control panel module
Remove and replace server board
Time
Estimate
1 min
5 min
1 min
7 min
1 min
12 min
10 min
2 min
15 min
10.6 Restriction of Hazardous Substances (RoHS) Compliance
Intel has a system in place to restrict the use of banned substances in accordance with the
European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
Note: RoHS implementing details are not fully defined and may change.
Threshold limits and banned substances are noted below.
• Quantity limit of 0.1% by mass (1000 PPM) for: o Lead o Mercury o Hexavalent o Polybrominated Biphenyls Diphenyl Ethers (PBDE)
• Quantity limit of 0.01% by mass (100 PPM) for: o Cadmium
88
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Environmental and Regulatory Specifications
10.7 Regulated Specified Components
To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other component will void the UL listing and other product certifications and approvals.
Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder
If you do not have access to Intel’s Web address, please contact your local Intel representative.
Server Chassis (base chassis is provided with power supply and fans)
⎯UL listed.
Server board
⎯you must use an Intel server board—UL recognized.
Add-in boards
⎯must have a printed wiring board flammability rating of minimum
UL94V-1. Add-in boards containing external power connectors and/or lithium batteries must be UL recognized or UL listed. Any add-in board containing modem telecommunication circuitry must be UL listed. In addition, the modem must have the appropriate telecommunications, safety, and EMC approvals for the region in which it is sold.
Peripheral Storage Devices
⎯must be UL recognized or UL listed accessory and TUV or VDE licensed. Maximum power rating of any one device is 19 watts. Total server configuration is not to exceed the maximum loading conditions of the power supply.
Revision – 1.00
Intel order number D31980-004
89
Platform Control
11. Platform Control
Intel® Server System SR2500AL
This server platform has embedded platform control which is capable of automatically adjusting system performance and acoustic levels.
P
M e a r n f f o a r g m e a m n e c n e t
P e r f f o r m a
T h r o t t l l i i a n n g c e
I n t e g r a t
C o n t r t o l e l d
M a
A c o u s t i i c n a g e m c m e n t M
T o h n e i i r t m o r i a l l n n g
F a
C n o
S n t p r e o e l l d
11.1 Overview
Platform control optimizes system performance and acoustics levels through:
Performance Management
Performance Throttling
Thermal Monitoring
Fan Speed Control
Acoustics Management
The system components used to implement platform control include:
90
Baseboard Management Controller functions of the ESB-2
LM94 Sensor Monitoring Chip
Platform Sensors
Variable Speed System Fans
System BIOS
BMC Firmware
Sensor Data Records as loaded by the FRUSDR Utility
FBDIMM type
Processor type
Intel order number D31980-004
Revision – 1.00
11.2 FBDIMM Open Loop Throughput Throttling
Memory throttling is a feature of the Intel
®
5000 Series Chipsets to prevent FBDIMM memory from overheating. If the performance of the installed FB-DIMMs approaches their supported thermal limit for a given platform, the system BIOS will initiate memory throttling which manages memory performance by limiting bandwidth to the DIMMs, therefore capping the power consumption and preventing the DIMMs from overheating. Memory throttling can be minimized by operating your platform in “Performance Mode” (default) which changes the system Fan
Control profile to run the system fans at higher speeds. Running the platform in “Acoustics
Mode” will cause the system fans to run slower to meet the acoustic limits for the given platform.
System BIOS utilizes a Memory Reference Code (MRC) throttling algorithm to maximize memory bandwidth for a given configuration when memory throttling is initialized. The MRC code relies on Serial Presence Detect (SPD) data read from the installed DIMMs as well as system level data as set through BIOS Setup Options and the FRUSDR Utility.
FBDIMM Inputs
(SPD bytes)
System Level Inputs
BIOS Setup & FRUSDR
Power
Property
System
Ambient
Memory
Throttle
Heat
Spreader
DRAM Type
+
Trise
BIOS MRC
Fan Flow
Velocity
AMB Thermal
Limit
DRAM
Thermal Limit
Altitude
Pitch
11.3 Fan Speed Control
System fan speed is controlled by the Baseboard Management Controller (BMC) functions of the ESB-2 chip. During normal system operation, the BMC will retrieve information from BIOS and monitor several platform thermal sensors to determine the required fan speeds.
In order to provide the proper fan speed control for a given system configuration, the BMC must have the appropriate platform data programmed. Platform configuration data is programmed using the FRUSDR Utility during the system integration process and by System BIOS during run time.
Revision – 1.00
Intel order number D31980-004
91
Platform Control Intel® Server System SR2500AL
The Field Replaceable Unit & Sensor Data Record Update Utility (FRUSDR utility) is a program used to write platform specific configuration data to NVRAM on the server board. It allows the
User to select which supported chassis (Intel or Non-Intel) and platform chassis configuration is being used. Based on the input provided, the FRUSDR writes sensor data specific to the configuration to NVRAM for the BMC controller to read each time the system is powered on.
11.3.2 Fan Speed Control from BMC and BIOS Inputs
Using the data programmed to NVRAM by the FRUSDR utility, the BMC is configured to monitor and control the appropriate platform sensors and system fans each time the system is powered on. After power-on, the BMC uses additional data provided to it by System BIOS to determine how the system fans should be controlled.
The BIOS provides data to the BMC telling it which fan profile the platform is setup for,
Acoustics Mode or Performance Mode. The BIOS uses the parameters retrieved from the thermal sensor data records (SDR), the fan profile setting from BIOS Setup, and the altitude setting from BIOS Setup to configure the system for memory throttling and fan speed control. If the BIOS fails to get the Thermal SDRs, then it will use the Memory Reference Code (MRC) default settings for the memory throttling settings.
The <F2> BIOS Setup Utility provides options to set the fan profile or operating mode the platform will operate under. Each operating mode has a predefined profile for which specific platform targets are configured, which in turn determines how the system fans operate to meet those targets. Platform profile targets are determined by which type of platform is selected when running the FRUSDR utility and by BIOS settings configured using the <F2> BIOS Setup Utility.
11.3.2.1 Configuring the Fan Profile Using the BIOS Setup Utility
The BIOS uses options set in the <F2> BIOS Setup Utility to determine what fan profile the system should operate under. These options include “SET FAN PROFILE” and “ALTITUDE”.
The “SET FAN PROFILE” option can be set to either the “Performance” mode (Default), or
“Acoustics” mode. See the following sections for detail describing the difference between each mode. Changing the fan profile to Acoustics mode may affect system performance.
The “ALTITUDE” option is used to determine appropriate memory performance settings based on the different cooling capability at different altitudes. At high altitude, memory performance must be reduced to compensate for thinner air. Be advised, selecting an Altitude option to a setting that does not meet the operating altitude of the server may limit the system fans ability to provide adequate cooling to the memory. If the air flow is not sufficient to meet the needs of the server even after throttling has occurred, the system may shut down due to excessive platform thermals.
By default, the Altitude option is set to 301Meters – 900 Meters which is believed to cover the majority of the operating altitudes for these server platforms.
The following Diagrams show which BIOS Setup Utility menu is used to configure the desired
Fan Profile.
92
Intel order number D31980-004
Revision – 1.00
Advanced
System Acoustic and Performance Configuration
Set Fan Profile
Altitude
Performance / Acoustics
300 M or less / 301 M - 900 M / Higher than 900 M
Setup Item
Set Fan Profile
Altitude
Option
Performance
Acoustic
300 M or less
301 M - 900 M
Higher than 900 M
Help Text
Select the fan control profile that will be used to cool the system.
300 M or less (<= 980ft): Provides the best performance option for servers operating at or near sea level.
301 M – 900 M (980ft - 2950ft): Provides the best performance option for servers operating at moderate altitudes above sea level.
Higher than 900 M (>2950ft): Provides the best performance option for servers operating at high elevations above sea level.
Comments
Performance mode favors using fans over throttling memory bandwidth to cool the system.
Note: Fan speed control for non-Intel chassis, as configured after running the FRUSDR utility and selecting the Non-Intel Chassis option, is limited to only the CPU fans. The BMC only requires the processor thermal sensor data ito determine how fast to operate these fans. The remaining system fans will operate at 100% operating limits due to unknown variables associated with the given chassis and its fans. Therefore, regardless of whether the system is configured for Performance Mode or Acoustics Mode, the System fans will always run at 100% operating levels providing for maximum airflow. In this scenario the Performance and Acoustic mode settings only affects the allowable performance of the memory (higher BW for the
Performance mode).
11.3.2.2 Performance Mode (Default)
With the platform running in Performance mode (default), several platform control algorithm variables are set to enhance the platform’s capability of operating at maximum performance targets for the given system. In doing so, the platform is programmed with higher fan speeds at lower external temperatures. This will result in a louder acoustic level than is targeted for the given platform, but the increased airflow of this operating mode will greatly reduce possible memory throttling from occurring and will reduce dynamic fan speed changes based on processor utilization.
With the platform running in Acoustics mode, several platform control algorithm variables are set to ensure acoustic targets are not exceeded for specified Intel platforms. In this mode, the
Revision – 1.00
Intel order number D31980-004
93
Platform Control Intel® Server System SR2500AL platform is programmed to set the fans at lower speeds when the processor does not require additional cooling due to high utilization / power consumption. Memory throttling will be utilized to ensure that the memory thermal limits are not exceeded.
94
Intel order number D31980-004
Revision – 1.00
< This page intentionally left blank >
Revision – 1.00
Intel order number D31980-004
95
Appendix A: Chassis Integration and Usage Tips Intel® Server System SR2500AL
Appendix A: Chassis Integration and Usage Tips
This appendix provides a list of useful information that is unique to the Intel
®
Server Chassis
SR2500 and should be kept in mind while integrating and configuring your system. o In a single power supply configuration, the power supply must be placed in the lower slot. A power supply blank must be installed in the upper slot in order to maintain proper airflow in the system. o Do not mix DIMMs of different heights. For tall DIMMS the DIMM baffle must be removed from the Processor Air Duct for proper fitment. The baffle must be installed for shorter
DIMMS to ensure proper airflow and DIMM cooling. o You must run the FRUSDR utility to load the proper Sensor Data Records for this chassis on to the server board. Failure to do so may result in possible false errors being reported to the
System Event Log. It is best to download the latest FRUSDR Utility for your particular server board using the Intel
®
Server Deployment Toolkit or from the following web site: http://support.intel.com/support/motherboards/server o To ensure proper cooling of your server, all air baffles and air ducts must be in place. In addition, all drive bays must be populated with either a drive or a drive blank and both power supply slots must be populated by either a power supply or a power supply blank. o Processor fans are not supported and are not needed in the Intel
®
Server Chassis SR2500. o The Mid-plane board must be removed from the system before removal of the Backplane. o In order to remove or replace the Mid-plane board, the fan cage must first be removed. o There are three indentations in the top of the chassis. These are for the Intel Safety Label, the Windows Certification Label, and a Customer Defined Label.
96
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Appendix B: POST Code Diagnostic LED Decoder
Appendix B: POST Code Diagnostic LED Decoder
During the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board. To assist in troubleshooting a system hang during the POST process, the Diagnostic LEDs can be used to identify the last POST process to be executed.
Each POST code will be represented by a combination of colors from the four LEDs. The LEDs are capable of displaying three colors: green, red, and amber. The POST codes are divided into two nibbles, an upper nibble and a lower nibble. Each bit in the upper nibble is represented by a red LED and each bit in the lower nibble is represented by a green LED. If both bits are set in the upper and lower nibbles then both red and green LEDs are lit, resulting in an amber color. If both bits are clear, then the LED is off.
In the below example, BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs are decoded as follows:
• red bits = 1010b = Ah
• green bits = 1100b = Ch
Since the red bits correspond to the upper nibble and the green bits correspond to the lower nibble, the two are concatenated to be ACh.
LEDs
Table 56: POST Progress Code LED Example
Red
8h
Green Red
4h
Green
Result Amber Green
MSB
Red
2h
Green
Red
Red
1h
Green
Off
LSB
USB Port USB Port
Back edge of baseboard
Diagnostic LEDs
MSB LSB
Figure 52. Diagnostic LED Placement Diagram
Revision – 1.00
Intel order number D31980-004
97
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR2500AL
Table 57. Diagnostic LED POST Code Decoder
Description
Checkpoint
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB
Host Processor
LSB
Chipset
0x21h
Memory
0x23h
0x24h
0x25h
OFF OFF R G Initializing a chipset component
OFF OFF
OFF
OFF
G
G
A
R
R
G Detecting presence of memory
OFF Programming timing parameters in the memory controller
G Configuring memory parameters in the memory controller
PCI Bus
0x50h
0x51h
0x52h
0x53h
0x54h
0x55h
0x56h
0x57h
USB
0x58h
0x59h
ATA / ATAPI / SATA
0x5Ah G
0x5Bh G
SMBUS
G
G
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
A
A
A
R OFF
R OFF
R
R
A
G
G
OFF
OFF
G
G
R OFF
R OFF
R
R
G
G
R Enumerating PCI busses
A Allocating resources to PCI busses
R Hot Plug PCI controller initialization
A Reserved for PCI bus
R Reserved for PCI bus
A Reserved for PCI bus
R Reserved for PCI bus
A Reserved for PCI bus
R Resetting USB bus
A Reserved for USB devices
R Resetting PATA / SATA bus and all devices
A Reserved for ATA
0x5Dh
Local Console
G
0x70h
0x71h
0x72h
OFF
OFF
OFF
Remote Console
A
R
R
R
OFF
R
R
A
0x78h
0x79h
0x7Ah
G
G
G
R
R
R
R
R
A
Keyboard (PS2 or USB)
0x90h R OFF OFF
0x91h R OFF OFF
A Reserved for SMBUS
R Resetting the video controller (VGA)
A Disabling the video controller (VGA)
R Enabling the video controller (VGA)
R Resetting the console controller
A Disabling the console controller
R Enabling the console controller
R Resetting the keyboard
A Disabling the keyboard
98
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL
Checkpoint
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB LSB
Appendix B: POST Code Diagnostic LED Decoder
Description
0x93h
0x94h
0x95h
R
R
R
Mouse (PS2 or USB)
0x98h
0x99h
A
A
OFF
G
G
OFF
G OFF
OFF OFF
OFF OFF
A Enabling the keyboard
R Clearing keyboard input buffer
A Instructing keyboard controller to run Self Test (PS2 only)
R Resetting the mouse
A Detecting the mouse
0x9Bh
Fixed Media
A OFF G A Enabling the mouse
0xB0h
0xB1h
0xB2h
0xB3h
Removable Media
0xB8h A
R
R
OFF
OFF
R
R
R Resetting fixed media device
A Disabling fixed media device
Detecting presence of a fixed media device (IDE hard drive detection,
R OFF A R etc.)
R OFF A A Enabling / configuring a fixed media device
OFF R R Resetting removable media device
0xB9h
0xBAh
0xBCh
0xD2
0xD3
0xD4
0xD5
0xD6
0xD7
0xD8
0xD9
0XDA
0xDB
0xDC
0xDE
A OFF R A Disabling removable media device
Detecting presence of a removable media device (IDE CDROM
A OFF A R detection, etc.)
A G R R Enabling / configuring a removable media device
Boot Device Selection
0xD0 R
0xD1 R
R OFF
R OFF
R
R
R
R
R
R
A
A
A
A
A
A
R
R
A
A
A
A
R
R
R
R
A
A
G
G
OFF
OFF
G
G
OFF
OFF
G
G
OFF
G
0xDF A A
Pre-EFI Initialization (PEI) Core
G
R
A
Trying boot device selection
Trying boot device selection
R Trying boot device selection
A Trying boot device selection
R Trying boot device selection
A
R
A
Trying boot device selection
Trying boot device selection
Trying boot device selection
R Trying boot device selection
A Trying boot device selection
R Trying boot device selection
A Trying boot device selection
R Trying boot device selection
R
A
Trying boot device selection
Trying boot device selection
0xE2h
0xE1h
R
R
R
R
A
R
OFF Initial memory found, configured, and installed correctly
G Reserved for initialization module use (PEIM)
0xE3h R R A G Reserved for initialization module use (PEIM)
Driver Execution Environment (DXE) Core
0xE5h R A R G Started dispatching drivers
DXE Drivers
0xE7h R
Revision – 1.00
A A G Waiting for user input
Intel order number D31980-004
99
Appendix B: POST Code Diagnostic LED Decoder
Checkpoint
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB LSB
0xE9h A R R G Entering BIOS setup
0xEEh A A
Intel® Server System SR2500AL
Description
A OFF Calling Int 19. One beep unless silent boot is enabled.
Runtime Phase / EFI Operating System Boot
0xF4h R A R R Entering Sleep state
0xF8h
0xF9h
0xFAh
A R R R
(ExitBootServices ( ) has been called)
Operating system has switched to virtual address mode
A R R A
(SetVirtualAddressMap ( ) has been called)
Operating system has requested the system to reset (ResetSystem ()
A R A R has been called)
Pre-EFI Initialization Module (PEIM) / Recovery
0x30h OFF OFF R R Crisis recovery has been initiated because of a user request
0x31h OFF OFF R A Crisis recovery has been initiated by software (corrupt flash)
0x34h
0x35h
0x3Fh
OFF
OFF
G
G
G
G
R
R
A
R
A
A
Loading crisis recovery capsule
Handing off control to the crisis recovery capsule
Unable to complete crisis recovery.
100
Intel order number D31980-004
Revision – 1.00
Intel® Server System SR2500AL Appendix C: POST Error Beep Codes
Appendix C: POST Error Beep Codes
The following table lists POST error beep codes. Prior to system Video initialization, BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user visible code on POST Progress LEDs.
Table 58. POST Error Beep Codes
Beeps
3
Error Message
Memory error
6 BIOS rolling back error
POST Progress Code Description
System halted because a fatal error related to the memory was detected.
The system has detected a corrupted BIOS in the flash part, and is rolling back to the last good BIOS.
The BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are common across all Intel
®
server boards and systems that use the Intel
®
5000 Series Chipsets are listed in Table 59. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit.
Table 59. BMC Beep Codes
Code Reason for Beep
1-5-2-1 CPU: Empty slot / population error – Processor slot 1 is not populated.
1-5-2-2 CPU: No processors (terminators only)
Associated Sensors
CPU Population Error
N/A
1-5-2-3 CPU: Configuration error (e.g., VID mismatch) N/A
1-5-2-4 CPU: Configuration error (e.g., BSEL mismatch) N/A
1-5-4-2 Power fault: DC power unexpectedly lost (power good dropout)
Power Unit – power unit failure offset
1-5-4-3 Chipset control failure
1-5-4-4 Power control fault
N/A
Power Unit – soft power control failure offset
Supported?
Yes
No
No
No
Yes
No
Yes
Revision – 1.00
Intel order number D31980-004
101
Glossary
Glossary
Word / Acronym
ACA Australian Communication Authority
Definition
BMC
CMOS
Baseboard Management Controller
Complementary Metal Oxide Silicon
D2D DC-to-DC
EMP Emergency Management Port
FRB
FRU
LCD
MTBF
MTTR
Fault Resilient Boot
Field Replaceable Unit
Liquid Crystal Display
Mean Time Between Failure
Mean Time to Repair
Intel® Server System SR2500AL
PFC
PSU
Power Factor Correction
Power Supply Unit
SCA Single Connector Attachment
SDR Sensor Data Record
SE Single-Ended
UART Universal Asynchronous Receiver Transmitter
USB
VCCI
Universal Serial Bus
Voluntary Control Council for Interference
102
Intel order number D31980-004
Revision – 1.00
Reference Documents
See the following documents for additional information: o Intel
®
Server Board S5000PAL Technical Product Specification o Intel
®
5000 Series Chipsets Server Board Family Datasheet o Intel
®
Server Chassis SR2500 Power Distribution Board for 750W Power Supply
Specification o Intel
®
Server Chassis SR2500 750 Watt AC Power Supply Module Specification o Intel
®
Server Board S5000PAL/S5000XAL Tested Hardware and OS List
Revision – 1.00
Intel order number D31980-004
103
Download
Advertisement