Swegon REACTa Installation Instructions
PDF
เอกสาร
โฆษณา
โฆษณา
REACT Modbus 20150922 Transmission protocol Protocol: ModBus / RTU Baud rate: 1200, 2400, 4800, 9600, 19200, 38400 Byte sequence: MSB / LSB Byte format: 8 data bits, 2 stop bits, none parity 8 data bits, 1 stop bits, even parity 8 data bits, 1 stop bits, odd parity Resistance: 120 Ohm (external) Delay: Some master devices need a certain amount of time to switch from the transmission mode to reception mode. The delay time can be set in 3 ms steps. Maximum 765 ms (255 × 3 ms) Response time: ≤ 10 ms + delay. Standard communication parameter: 1 start bit Communication setting 14 19200 baud 8 data bits 1 stop bits even parity delay 0 ms The values of baud rate, parity, stop-bit and delay are programmable. Function-code Modbus Following functions codes are implemented: Function code Name Description 03h Read hold register Device parameter / actual values read (integer / float) 06h Write single register Device parameter single word write REACT Modbus Holding register Costumer (parameter table) Name 2 Address decimal Data type Value range r/w Description Set point 0 WORD 0…10000 r/w Set point [%] 0=0%, 10000=100% see register 122: '0': set point is read only Override control 1 WORD 0…4 r/w Override control '0’ Override control not available '1’ open '2‘ close '3' min '4' max Command 2 WORD 0…4 r/w Command '0’ - - '1’ adaption '2‘ - - '3' - - '4' controller reset Device ID 3 WORD 0..3 r Device ID '0’ - - '1’ standard actuator '2‘ VAV '3' fire damper Relative position 4 WORD 0…10000 r Relative position [%] 0=0%, 10000=100% 65535 = this function is not supported Absolute position 5 WORD 0…65000 r Absolute position [°] 0..650.00 65535 = this function is not supported Relative flow 6 WORD 0…10000 r VAV flow [%] 0=0%, 10000=100% Absolute flow 7 WORD 0…65535 r VAV flow [m³/h][l/s] Analog output (optional) 10 WORD [mV] 0…10000 r/w Analog output [mV] 0 ..10000 see register 122 Swegon reserves the right to alter specifications. 20150922 REACT Modbus Service Values Name Address decimal Data type Value range r/w Description Software version 103 WORD 1..65535 r Software version Min value relative 105 WORD 0..10000 r/w Min flow in % of nominal flow [%] 0=0%, 10000=100% Max value relative 106 WORD 0..10000 r/w Max flow in % of nominal flow [%] 0=0%, 10000=100% Bus fail position 108 WORD 0..2 r/w Bus fail position '0’ - - No bus monitoring '1' at timeout position close bus monitoring timeout 120s '2’ at timeout position open bus monitoring timeout 120s Min value absolute 120 WORD 0..65535 r/w Min value [m³/h][l/s] Max value absolute 121 WORD 0..65535 r/w Max value [m³/h][l/s] Mode signal set point analog output Modbus address 122 130 WORD WORD 0..3 1 -247 r/w r/w Value Referencing signal Analog Out 0 Analog In 1 [V] 0(2)…10 Absolute position [V] 0 ..10 1 Communication via Modbus register 0 absolute position[V] 0 ..10 2 Communication via Modbus register 0. 0% = Min. flow, 100% = Max. flow Value register 10 3 Analog IN 1 [V] 0(2)…10 Value register 10 Modbus address 1 – 247 20150922 Swegon reserves the right to alter specifications. 3 REACT Modbus Customer values Name Address decimal Data type Value range r/w Description Vnom Vnom 201 unit/function WORD 0…1 r/w '0’ [l/s], '1’ [m³/h] Error handling Error code Name Description 01h Illegal function The function code received in the query is not an allowable action. 02h Illegal data address The data address received in the query is not an allowable register address. Register address are read only. 03h Illegal data value A value contained in the query data field is not an allowable value. Wrong number of registers. Register address are read only. 06h Slave device busy Specialized use in conjunction with programming commands. The server (or slave) is engaged in processing a long–duration program command. Description interface parameter ModBus Display number 4 EEPROM value Baudrate Parity Stop bits 1 0 1200 None 2 2 1 1200 Even 1 3 2 1200 Odd 1 4 3 2400 None 2 5 4 2400 Even 1 6 5 2400 Odd 1 7 6 4800 None 2 8 7 4800 Even 1 9 8 4800 Odd 1 10 9 9600 None 2 11 10 9600 Even 1 12 11 9600 Odd 1 13 12 19200 None 2 14 13 19200 Even 1 15 14 19200 Odd 1 16 15 38400 None 2 17 16 38400 Even 1 18 17 38400 Odd 1 Swegon reserves the right to alter specifications. 20150922 ">
/
ดาวน์โหลด
ขอแจ้งให้ทราบ คุณสามารถดูเอกสารได้ที่นี่ แต่ที่สำคัญที่สุดคือ AI ของเราได้อ่านแล้ว สามารถอธิบายสิ่งที่ซับซ้อนด้วยคำศัพท์ง่ายๆ ตอบคำถามของคุณในทุกภาษา และช่วยคุณนำทางเอกสารที่ยาวหรือซับซ้อนที่สุดได้อย่างรวดเร็ว
โฆษณา