Swegon REACT Parasol Zenith inställningar - Belimo Owner's Manual
Swegon REACT Parasol Zenith is a versatile device offering a wide range of features for controlling and monitoring your indoor climate. With Modbus communication capabilities, it seamlessly integrates into your existing building management system, enabling remote access and control. Adjust setpoints, monitor sensor values, and receive malfunction and service information, all from the convenience of your centralized interface. Additionally, the device provides various control modes, including position control and flow control, to adapt to your specific requirements.
PDF
เอกสาร
โฆษณา
โฆษณา
REACT Parasol Zenith Modbus settings / Modbus-inställningar Modbus settings for REACT Parasol Zenith with Belimo actuator Modbus-inställningar för REACT Parasol Zenith med ställdon Belimo 20220810 REACT Parasol Zentih Transfer protocol Överföringsprotokoll Protocol: Modbus RTU Protokoll: Modbus RTU Number of nodes Max.32 (without repeater) Antal noder max. 32 Baud rates: 9600, 19200, 38400, 76800, 115200 Kommunikationshastighet: 9600, 19200, 38400, 76800, 115200 Bit sequence: LSB Bitsekvens: LSB Transmission formats: 1-8-N-2, 1-8-N-1, 1-8-E-1, 1-8-O-1 Bitformat: 1-8-N-2, 1-8-N-1, 1-8-E-1, 1-8-O-1 Terminating resistor: 120 Ohm (extern) Termineringsmotstånd: 120 Ohm (extern) Response time: ≤ 10 ms + delay Svarstid: ≤ 10 ms + fördröjning Standard communication parameter: 1 Start bit Standard kommunikationsparameter: 1 startbit Communication setting: 14 19200 baud Kommunikationsinställning: 14 8 Data bits 19200 baud 8 databitar 1 Stop bit 1 stoppbit Even parity Jämn paritet Delay 0 ms Fördröjning 0 ms The values for communication speed, parity, stop bits and delay are changeable. Värdena för kommunikationshastighet, paritet, stoppbitar och fördröjning är ändringsbara. Modbus Register Overview Modbus Register Översikt Operation Operation No. Address Access Nr. Adress 1 0 Setpoint [%] R/W 1 0 Börvärde [%] R/W 2 1 Override control R/W 2 1 Tvångsstyrning R/W 3 2 Command R/W 3 2 Kontroll R/W 4 3 Actuator type R 4 3 Ställdonstyp R 5 4 Relative position [%] R 5 4 Relativ position [%] R 5 Absolut position [°] [mm] R Register Register R/W 6 5 Absolute position [°] [mm] R 6 7 6 Relative volumetric flow [%] R 7 6 Relativt volumetriskt flöde [%] R 8 7 Absolute volumetric flow [m³/h] R 8 7 Absolut volumetriskt flöde [m³/h] R 9 8 Sensor value 1 [mV] [–] R 9 8 Sensor värde 1 [mV] [–] R 10 9 – – 10 9 – 11 10 10 12 11 Absolute volumetric flow in unit selected 11 12 11 13 12 Setpoint analog [%] 13 12 LowWord HighWord R R – Absolut flöde i vald enhet LowWord HighWord Börvärde analogt [%] R R Service Service 2 x No. Address Access Nr. Adress 100 99 Bus termination R 100 99 Busterminering R R R Register Register 101 100 Series number 1st part 101 100 Serienummer 1:a delen 102 101 Series number 2nd part 102 101 Serienummer 2:a delen 103 102 Series number 4th part 103 102 Serienummer 4:e delen R/W 104 103 Firmware version R 104 103 Firmware version 105 104 Malfunction and service information R 105 104 Fel och serviceinfo R 106 105 Min [%] R/W 106 105 Min [%] R/W R 107 106 Max [%] R/W 107 106 Max [%] R/W 108 107 Sensor type 1 R/W 108 107 Sensor typ 1 R/W 109 108 Bus fail position R/W 109 108 Bus fel position R/W R/W 110 109 Kommunikationsövervakning R/W 110 109 Communication Watchdog 111 110 Nominal volumetric flow [m³/h] R 111 110 Nominellt flöde [m³/h] R 112 111 – – 112 111 – – 113 112 114 113 Nominal volumetric flow in unit selected LowWord HighWord R 113 112 114 113 Nominellt flöde i vald enhet LowWord HighWord R 115 114 – – 115 114 – 116 115 – – 116 115 – 117 116 Control Mode R/W 117 116 Styrsignal läge R/W 118 117 Unit Selection Flow R/W 118 117 Enhetsval flöde R/W 119 118 Setpoint source R/W 119 118 Börvärdeskälla R/W Swegon reserves the right to alter specifications 20220810 – – REACT Parasol Zenith Modbus Register Description No. Address Description Comment Beskrivning (SE) Range Enumeration 1 Unit Scaling Access 0 Setpoint Setpoint for actuator between Min (Register No. 106) and Max (No. 107) Börvärde Börvärde för ställdonet mellan min och max 0…10‘000 Default: 0 % 0.01 R/W 2 1 Override Control Override setpoint with defined values Tvångsstyrning Tvångsstyr börvärdet med fördefinierade värden 0: None 1: Open 2: Close 3: Min 4: Mid 5: Max Default: None(0) – – R/W 3 2 Command Initiation of actuator functions for service and test After command is sent, register returns to None(0) With Reset(4) all Malfunction and Service Information (Register No. 105) Information can be reset. Kontroll Initiering av ställdonets funktion 0: None 1: Adaption 2: Test 3: Sync 4: Reset Default: None(0) – – R/W 4 3 Actuator Type Ställdonstyp 0: Actuator not connected 1: Air / Water 2: VAV / EPIV 3: Fire 4: Energy Valve 5: 6way EPIV – – R % 0.01 R "° mm 1 1 R % 0.01 R 5 4 Relative Position Relativ position 0...10‘000 6 5 Absolute Position The unit depends on the device: [°] for actuators with rotary movement [mm] for actuators with linear movement Absolut position 0...max angle / stroke 7 6 Relative volumetric flow Relative volumetric flow of Vnom Relativt flöde 0...10‘000 8 7 Absolut volumetric flow Absolut flöde 0...Vnom m³/h Pa 1 R 9 8 Sensor 1 Value Current value of sensor 1, depending on the setting of the Sensor 1 Type (Register No. 108) [mV] if Sensor 1 Type (Register No. 108) is Active(1) [0 / 1] if Sensor 1 Type (Register No. 108) is Switch(4) Sensor 1 värde Strömvärde från sensor 1, beroende på sensorinställning 0...65‘535 mV 0 / 1 1 R 10 9 – 11 10 Absolute volumetric flow Absolute flow in unit selected (Register No. 118) LowWord Lower 16 bit of 32 bit value Absolut flöde, lågt byte 12 11 Absolute volumetric flow Absolute flow in unit selected (Register No. 118) HighWord Upper 16 bit of 32 bit value Absolut flöde, högt byte 13 12 Setpoint Analog Shows the setoint in % if actuator is control by analog signal Börvärde analogt 20220810 – – – – – UnitSel 0.001 R % 0.01 R 0...10‘000 Swegon reserves the right to alter specifications 3 REACT Parasol Zentih Modbus Register Description No. Address Description Comment Beskrivning (SE) 100 99 Bus Termination Indicates if bus termination (120 Ω) is enabled Bus termination can be set with the configuration tools Busterminering 101 100 Series Number 1st part Each device has an unambiguous series number, which is either impressed on or glued to the housing The series number consists of 4 segments, although only parts 1, 2 and 4 are displayed on Modus Example: 00839-31324-064-008 1st part: 00839 2nd part: 31324 4th part: 008 102 101 Range Enumeration Unit Scaling Access 0: inactive 1: active Default: inactive(0) – – R/W Indikerar om Bus-terminering är aktiv – – – R Series Number 2nd part Serienummer – – – R 103 102 Series Number 4th part Serienummer – – – R 104 103 Firmware Version Firmware version of communication module Example: 302, Version 3.02 Firmware version – – – R 105 104 Malfunction and Service Information Value is bit-coded. More than one bit can be set to 1 All bits not montioned in the enumeration are not used for this actuator range Mechanical travel increased: The actuator has been moved outside the adapted working range Actuator cannot move: Mechanical overload e.g. blocked actuator, etc. Internal activity: Actuator performs a test run, adaption, etc. Gear disengaged: The gear disengaged button is pressed Bus Watchdog triggered: Timeout for the Bus Watchdog expired Fel och serviceinformation, Bitkodat värde Bit1: Bit2: Bit8: Bit9: Bit10: – – R 106 105 Vmin Min has to be ≤ Max Vmin 0...Vmax Default: 0 % 0.01 R/W 107 106 Vmax Max has to be ≥ Min and > 20% Vmax Vmin...10‘000 Default: 10‘000 % 0.01 R/W 108 107 Sensor 1 Type If Setpoint Source (Register 119) is analog (Hybrid mode) the sensor type 1 can be set to Active(1) in order to see the Setpoint Analog in mV Sensor 1 typ 0: None 1: Active / Hybrid 2: – 3: – 4: Switch Default: None(0) – – R/W 109 108 Bus Fail Position Modbus communication is not monitored as standard. In the event of a breakdown in communication, the actuator retains the current setpoint The bus implementation tracks the Modbus communication. If neither the Setpoint (Register No. 1) nor the Override Control (Register No. 2) is renewed before the Timeout for Bus Watchdog (Register No. 110) expires, the actuator controls to the Bus Fail Position Triggered bus watchdog is indicated in the Malfunction and Service Information (Register No. 105) Bus fel position 0: None / Last setpoint 1: Fast close 2: Fast open 3: Mid position (parameterized) Default: None(0) – – R/W 110 109 Timeout for Bus Watchdog in s Time until Bus Fail will be detected. If Bus Watchdog = 0 then deactivated If Bus Fail Position (Register No. 110) different from 0, the Bus Fail Position becomes active after the Timeout for Bus Watchdog is expired Timeout för Busövervakning i s 0...3‘600 Default: 0 If Bus Fail Position (Register No. 110) not None(0), then Default: 120 s 1 R/W 4 Swegon reserves the right to alter specifications 20220810 Mech travel increased Actuator cannot move Internal activity Gear disengaged Bus Watchdog triggered REACT Parasol Zenith Modbus Register Description No. Address Description Comment Beskrivning (SE) Range Enumeration Unit Scaling Access 111 110 Nominal volumetric flow Nominellt volumetriskt flöde – m³/h 1 R 112 111 – Nominellt volumetriskt flöde LW – – – – 113 112 Nominal volumetric flow Vnom in unit selected (Register 118) LowWord Lower 16 bit of 32 bit value Nominellt volumetriskt flöde HW – UnitSel 0.001 R 114 113 Nominal volumetric flow Vnom in unit selected (Register 118) HighWord Upper 16 bit of 32 bit value 115 114 – – – – – 116 115 – – – – – 117 116 Control Mode Läge styrning 0: Position control 1: Flow control – – R/W 118 117 Unit Selection Flow Enhetsinställning flöde 0: m³/s 1: m³/h 2: l/s 3: l/min 4: l/h 5: gpm 6: cfm Default: m³/h(1) – – R/W 119 118 Setpoint Source Analog: Setpoint from analog signal 0 ... 10 V on wire 3 Bus: Setpoint from Modbus (Register 1) Börvärdeskälla Analog: Börvärde från analogsignal 0-10V Bus: Börvärde från Modbus 0: Analog 1: Bus Default: Bus(1) – – R/W 20220810 Swegon reserves the right to alter specifications 5 ">
/
ดาวน์โหลด
ขอแจ้งให้ทราบ คุณสามารถดูเอกสารได้ที่นี่ แต่ที่สำคัญที่สุดคือ AI ของเราได้อ่านแล้ว สามารถอธิบายสิ่งที่ซับซ้อนด้วยคำศัพท์ง่ายๆ ตอบคำถามของคุณในทุกภาษา และช่วยคุณนำทางเอกสารที่ยาวหรือซับซ้อนที่สุดได้อย่างรวดเร็ว
โฆษณา