SPECIFICATIONS Integrated radio receiver for reception of time signal Temperature Range: 23.0 to 122.0° F -5.0 to 50.0°C SETTING THE TIME ZONE AND DST STATUS Press and hold the SET/WAVE for 3 seconds, the Daylight Saving (DST) status (On/OFF) and Time Press the + button to toggle through the four (4) user-selectable time zones: appear to the left of the Signal Strength Indicator.) OPERATION The unit contains a pre-tuned internal radio receiver that receives a 60 kHz frequency signal generated by the U.S. Atomic Clock. The U.S. Atomic Clock is located in Boulder Colorado and is operated by NIST (National Institute of Standards and Technology). M = Mountain Standard Time (when selected, “M” will appear to the left of the Signal Strength Indicator.) C = Central Standard Time (when selected, “C” will appear to the left of the Signal Strength Indicator.) Upon installation of the batteries, the unit automatically activates its receiver. E = Eastern Standard Time (when selected, “E” will appear to the left of the Signal Strength Indicator.) The unit may not receive a signal immediately. It may take as long as 72 hours to receive a complete signal from the Atomic Clock. The clock will attempt a signal reception for 10 minutes every 3 hours until it successfully receives the signal from the atomic clock. While the unit is attempting Daylight Saving Time Each time the – button is pressed, Daylight Saving Time will be turned on/off. clock may be set manually (see the “Manual Clock Setting” section). Best reception often occurs between midnight and 4 am. mode. The successful reception of the Atomic Clock signal is dependent upon the positioning and external electrical interference may prevent the unit from receiving a complete signal. The main causes for poor reception are heavily reinforced concrete and steel structures and/or placement of the unit close to video or PC monitors. There are certain areas of the Eastern United States where urban interference or signals from the United Kingdom’s Atomic Clock may distort or interfere with the signal from the U.S. Atomic Clock. Upon successful reception of the Atomic Clock signal, set the Time Zone to the desired setting (see the “Setting the Time Zone and DST Status” section). With the desired Time Zone and DST setting SELECTING °F/°C AND TIME FORMAT 1. Press and hold the SET/WAVE for 3 seconds, the Daylight Saving (DST) status (On/OFF) and 2. Press the SET/WAVE button four (4) times, the time format (24Hr/12Hr) and temperature will 3. Each press of the – button will change the temperature display mode between °F and °C. 4. Each press of the + button will change the time format mode between AM/PM (12Hr) and 24 hour (24Hr). 5. With the desired temperature unit of measure and time format selected, press the SET/WAVE mode. SIGNAL STRENGTH INDICATOR Appearing under Indicates completed signal reception and synchronization with the Atomic Clock. Flashing indicates that the unit is attempting to receive the signal from the Atomic Clock. If this condition continues for more than 72 hours, the unit should be repositioned for better reception. not appearing indicates no signal has been received. If this condition continues for more than 72 hours, the unit should be repositioned for better reception. Upon successful reception of the Atomic Clock signal, the unit will perform an automatic update every night at midnight and will make any time adjustments that might be necessary. If this update is not successful, the indicators will disappear and the unit will try to receive the signal again every hour for up to 4 hours. If signal reception is still unsuccessful, the clock will attempt a signal reception for 10 minutes every 3 hours until it successfully receives the signal from the atomic clock. MANUAL CLOCK SETTING 1. Press and hold the SET/WAVE for 3 seconds, the Daylight Saving (DST) status (On/OFF) and on the display. 3. Set the desired year by pressing the + or – button. Press and hold the button to change the display rapidly. 4. With the desired year on the display, press the 5. Set the desired date by pressing the + or – button. The date will cycle through the day the next month, the month will change. Press and hold the + or – button to change the date rapidly. 6. With the desired date on the display, press the 7. Set the desired time-of-day by pressing the + or – button. 8. With the desired time-of-day on the display, press the SET/WAVE button. The 12/24 hour 9. Set the desired time format by pressing the + button. 10. Set the desired temperature display by pressing the – button. 11. With the desired time format and temperature unit on the display, press the SET/WAVE button NOTE: Any manual changes made will be automatically overridden with the next completed signal reception from the Atomic Clock. MANUALLY INITIATING SIGNAL RECEPTION If the unit has been moved from a location where it was receiving a strong complete signal, it is recommended that you manually initial signal reception to insure that the unit will receive a complete signal in its new location. ALL OPERATIONAL DIFFICULTIES If this unit does not function properly for any reason, replace the batteries with new high quality batteries (see “Battery Replacement” section). Low battery power can occasionally cause any Replacing the batteries with new fresh batteries will To manually initiate signal reception: Press and release the SET/WAVE button will unit is attempting to receive the signal from the Atomic Clock. RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning, most commonly caused by ESD (electrostatic discharge) or radio interference. To reset the unit, press and hold down the button for 2 seconds. All settings will return to default values. Pressing the RESET button has a similar effect as removing and reinstalling the batteries. BATTERY REPLACEMENT Erratic readings, faint readings, or no display are all indications that the batteries must be replaced. Remove the battery cover. Remove the exhausted batteries and replace them with a two (2) new AA alkaline batteries. Replace the battery cover. Upon initial installation of the battery, the unit automatically initiates signal reception. (See the “Operation” section for more details.) WARRANTY, SERVICE, OR RECALIBRATION For warranty, service, or recalibration, contact: CONTROL COMPANY 4455 Rex Road Products TIP TEMPERATURE Friendswood, Texas 77546 USA 340 Broad Ph. 281W. 482-1714 • Fax Street 281 482-9448 E-mail [email protected] • www.control3.com Burlington, NJ 08016 1800-TIP-TEMP TRACEABLE ® JUMBO ATOMIC WALL CLOCK INSTRUCTIONS www.tiptemp.com ISO 17025 accredited as a Calibration Laboratory by A2LA. Control Company Cat. No. 1080 Traceable® is a registered trademark of © 2013 Control Company. Control Company. 92-1080-00 Rev. 0 070913 ">
/
Atsisiųsti
Tiesiog draugiškas priminimas. Dokumentą galite peržiūrėti tiesiog čia. Bet svarbiausia, kad mūsų AI jau jį perskaitė. Jis gali paaiškinti sudėtingus dalykus paprastais terminais, atsakyti į jūsų klausimus bet kuria kalba ir padėti greitai naršyti net ilgiausius ar sudėtingiausius dokumentus.
Reklama