IMPOR T ANT SAFETY INSTRUCTIONS
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH,
INJURY, OR SIGNIFICANT PROPERTY DAMAGE - For your protection, read and follow these warnings and instructions carefully before installing or maintaining this fixture. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK - To avoid electric shock, serious injury, or death, be certain that all electrical power is disconnected from the supply branch circuit conductors before installing or maintaining this fixture. This product must be installed and maintained in accordance with the applicable installation codes by a person familiar with the construction and operation of the product and the hazards involved.
WARNING: RISK OF PERSONAL INJURY - This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product.
Lithonia Lighting assumes no responsibility for claims arising out of improper or careless installation or handling of this product.
RISK OF FIRE - Lamps are hot. Keep combustible material away from hot parts.
RISK OF FIRE - Observe lamp manufacturer’s warnings, recommendations and restrictions on lamp operation and maintenance.
IMPORTANT SAFETY
INSTRUCTIONS
• Do not install a damaged fixture.
• This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
• Proper grounding is required to ensure personal safety. Be certain green lead from the fixture is connected to supply ground.
• Use code compliant connectors for all electrical connections.
• ALL work should be done by a qualified electrician.
• WARNING: NEVER connect or disconnect any component while power supply is engaged.
DELIVERY: Upon receipt of fixture and accessories (packed separately), thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Do not install damaged fixtures. Compare the catalog description listed on the packing slip with the fixture label on the inside of the housing to be sure you have received the correct merchandise.
TROUBLESHOOTING
If this fixture fails to operate properly, check to make sure:
CAUTION
Observe lamp manufacturer's recommendations and restrictions on lamp operations, including but not limited to ballast type, burning position, and cycling. Use ANSI rated lamps only. • The correct lamp is properly installed.
•
•
The fixture is wired correctly.
The lamp is not faulty.
Maintenance: For optimum performance, periodically clean reflector and lens with a soft, damp cloth.
• The fixture is grounded correctly.
• The line voltage at the fixture is correct.
Important: DO NOT use abrasive materials, glass cleaner or other solvents on lens or paint. Use only mild, soapy water.
Prior to Installation
Read carefully before installing light fixtures. If you do not understand these instructions, please contact your local Lithonia distributor before installing. Make sure your materials and installation meet local electrical codes and burial depths. Install only on GFCI protected circuit. Use silicone tape on all threaded parts to seal water out. Use only approved rigid metal conduit fitting and parts suitable for outdoor and wet location use.
INSTALLATION
2-IN-1 Mounting System: Tiered landscape lights can be mounted on standard 1/2" conduit or 3" diameter landscape flood post (LFP). Do not install in low lying locations where floods occur or water pools, or on walkways where it may cause tripping. Use a 1/2"rigid conduit riser to achieve desired height above conduit box cover.
CONDUIT MOUNTING
1. Conduit box must first be wired with 120V 60Hz supply current before wiring this fixture.
2. Connect supply wires to fixtue wires using UL listed wire connectors.
LANDSCAPE FLOOD POST MOUNTING
Refer to instructions included with the Landscape Flood Post.
WIRING
Caution: TURN OFF POWER AT CIRCUIT BREAKER. Use UL approved connectors for all electrical connections. Insulate all unused leads.
1. Feed supply cable through conduit to box.
2. Decide height of riser you need above conduit box or landscape flood post. Use only UL approved riser (not included) and coat threads of riser on both ends with teflon tape to ensure water tight seal. Feed wire from fixture through riser. Screw one end of riser into fixture, screw the other end into the conduitbox or landscape flood post adapter cap.
3. Strip 1/2" insulation off ends of wires.
4. Connect the black to black.
5. Connect the white to white.
6. Connect the ground wire (green or bare copper wire) from the fixture lead to the ground supply lead.
LAMP INSTALLATION AND RE-LAMPING
1. When lamping, turn power off at the circuit breaker and allow the fixture to cool adequately.
2. Prior to installing the lamp in the fixture, check to be sure the lamp is of proper type and wattage. Remove screws and lift off tiers. Unscrew diffuser. Screw the lamp securely into the socket, back the lamp out one to two turns, then screw the lamp back in, making sure it is secure. This properly seats the lamp in the socket. Replace diffuser. Replace tiers.
3. Restore power.