advertisement
Industrial Ethernet Gateways
MGate™ MB3170/3270
1 and 2-port advanced serial-to-Ethernet Modbus gateways
›
Configuration is exceptionally easy
Slave mode supports 16 TCP masters and up to 31 or 62 serial
›
›
› slaves at the same time
Master mode supports 32 TCP slaves at the same time
Emergency request tunnels ensure QoS control
Serial redirector function provided
Embedded Modbus protocol analyzer
Redundant dual DC power inputs
Built-in Ethernet cascading for easy wiring
Overview
The MB3170 and MB3270 are advanced Modbus gateways that provide maximum flexibility for integrating industrial Modbus networks of all types and sizes. They are designed to integrate Modbus TCP,
ASCII, and RTU devices in almost any master and slave combination, including serial master to serial slave, or simultaneous serial and
Ethernet masters. A special priority control feature allows urgent commands to obtain an immediate response. All models are ruggedly constructed, are DIN-rail mountable, and offer built-in optical isolation for serial signals as an option.
Integrate TCP Masters without Altering the Modbus RTU/ASCII Network or Software
The MB3270 can integrate Modbus TCP with Modbus RTU/ASCII, without modifying the existing Modbus RTU/ASCII architecture or software. With the serial redirector function, a serial master can maintain direct access to serial slave devices through a specially mapped serial port. This allows the serial and TCP masters to access serial slaves simultaneously.
Cascade Ethernet Ports for Easy Wiring
Advanced models of the MGate™ MB3000 series have two Ethernet ports to make network wiring easier. Dual Ethernet ports allow users to string multiple Modbus gateways together using standard RJ45
Ethernet cables, eliminating the need for a separate Ethernet switch.
1
Redundant Power Inputs
Advanced models of the MB3000 series have dual power inputs for greater reliability. The power inputs allow simultaneous connections to two live DC power sources, so that continuous operation is provided even if one power source fails. The higher level of reliability makes these advanced Modbus gateways ideal for demanding industrial applications.
w w w. m o x a . c o m i n f o @ m o x a . c o m
2
Industrial Ethernet Gateways
Warning by Relay Output
A relay output is provided for the Ethernet link and power input status.
The relay output gives maintenance engineers an additional tool for troubleshooting and maintenance.
Priority Control for Urgent Commands (patent pending)
As Modbus networks increase in size and complexity, the lag time between commands and responses becomes a major concern.
Advanced models of the MB3000 series provide a priority control function for urgent commands, allowing users to force certain commands to get an immediate response. Depending on your system’s requirements, different methods are available to define which commands receive priority.
Specifications
Ethernet Interface
Number of Ports: 2 (1 IP)
Speed: 10/100 Mbps, Auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Serial Interface
Number of Ports:
MB3170/3170I: 1
MB3270/3270I: 2
Serial Standards: RS-232/422/485, software selectable
Connectors:
MB3170/3170I: DB9 male for RS-232, Terminal block for RS-422/485
MB3270/3270I: DB9 male x 2
ESD Protection: 15 KV for all signals
RS-485 Data Direction Control: ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Terminator for RS-485: 120 Ω
Serial Communication Parameters
Data Bits: 7, 8
Stop Bits: 1, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS, DTR/DSR (RS-232 only)
Baudrate: 50 bps to 921.6 Kbps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Software
Operation Modes: RTU Slave, RTU Master, ASCII Slave, ASCII
Master
Utilities: MGate™ Manager for Windows 98/ME/NT/2000, Windows
XP/2003/Vista/2008/7 x86/x64
Multi-master and Multi-drop:
Master mode: 32 TCP slaves
Slave mode: 16 TCP masters (request queue 32-deep for each master)
Bonus Features: Smart Routing, Serial Redirection, Priority Control
Physical Characteristics
Housing: Plastic
Dimensions:
Without ears: 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
With ears extended: 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements
Input Voltage: 12 to 48 VDC
Power Connector: Terminal block
Power Consumption:
MGate™ M3170: 435 mA (max.)
MGate™ M3170I: 555 mA (max.)
MGate™ M3270: 435 mA (max.)
MGate™ M3270I: 510 mA (max.)
Regulatory Approvals
EMC: CE (EN55022 Class A and EN55024), FCC Part 15 Subpart B
Class A
Safety: UL (UL60950-1), TÜV (EN60950-1)
Hazardous Location:
UL/cUL Class 1 Division 2 Groups A, B, C, D
ATEX Class 1 Zone 2
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-23
Vibration: IEC 60068-2-6
Marine: DNV
EMS:
EN61000-4-2 (ESD): Level 3
EN61000-4-3 (RS): Level 3
EN61000-4-4 (EFT): Level 4
EN61000-4-5 (Surge): Level 3
EN61000-4-6 (CS): Level 3
EN61000-4-8: Passed
EN61000-4-11: Passed
EN61000-4-12: Passed
Reliability
MTBF (meantime between failures):
MGate™ M3170: 210794 hrs
MGate™ M3270: 125234 hrs
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty w w w. m o x a . c o m i n f o @ m o x a . c o m
Industrial Ethernet Gateways
Dimensions
20.6 mm
(0.81 in)
29.91 mm
(1.18 in)
9.2 mm (0.36 in)
7.2 mm (0.28 in)
7.1 mm (0.28 in)
7.2 mm (0.28 in)
7.1 mm (0.28 in)
29 mm
(1.14 in)
14.5 mm
(0.57 in)
14.5 mm
(0.57 in)
89.2 mm (3.51 in)
MGate™ MB3170
25.9 mm
(1.02 in)
35 mm
(1.38 in)
MGate™ MB3270
20 mm (0.79 in)
25.9 mm
(1.02 in)
35 mm
(1.38 in)
Ordering Information
Available Models
MGate™ MB3170: 1-port advanced Modbus gateway, 0 to 55°C operating temperature
MGate™ MB3170I: 1-port advanced Modbus gateway with 2 KV isolation, 0 to 55°C operating temperature
MGate™ MB3270: 2-port advanced Modbus gateway, 0 to 55°C operating temperature
MGate™ MB3270I: 2-port advanced Modbus gateway with 2 KV isolation, 0 to 55°C operating temperature
MGate™ MB3170-T: 1-port advanced Modbus gateway, -40 to 75°C operating temperature
MGate™ MB3170I-T: 1-port advanced Modbus gateway with 2 KV isolation, -40 to 75°C operating temperature
MGate™ MB3270-T: 2-port advanced Modbus gateway, -40 to 75°C operating temperature
MGate™ MB3270I-T: 2-port advanced Modbus gateway with 2 KV isolation, -40 to 75°C operating temperature
Optional Accessories (can be purchased separately)
DR-45-24: 24 VDC DIN-rail power supply (2 A @ 45 W) with universal 85 to 264 VAC input
DR-75-24: 24 VDC DIN-rail power supply (3.2 A @ 75 W) with universal 85 to 264 VAC input
DR-120-24: 24 VDC DIN-rail power supply (5 A @ 120 W) with switch for choosing 88 to 132 VAC, or 176 to 264 VAC input
•
•
•
Package Checklist
• MGate™ MB3170 or MB3170I or MB3270 or MB3270I Modbus Gateway
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
3 © Moxa Inc. All Rights Reserved. Updated Mar. 17, 2010. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.