Tripp Lite SmartOnline 208/120V or 240/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, LCD, USB, DB9 Serial Datasheet
Add to my manuals
6 Pages
Tripp Lite SU6000RT4UTFHW is a 6kVA double-conversion UPS system that offers complete power protection for critical equipment. It features full-time active power conditioning, fault-tolerant auto-bypass, and detachable back panel PDU. The UPS also supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in interfaces. It includes PowerAlert monitoring software for detailed power updates and UPS control options. The UPS has a maximum installed rack depth of 21.8 inches and maintains full-time sine wave output within 2% of selectable voltage.
advertisement
SmartOnline 208/120V or 240/120V 6kVA 5.4kW
On-Line Double-Conversion UPS, Extended Run,
SNMP, Webcard, 6U Rack/Tower, LCD, USB, DB9
Serial
MODEL NUMBER: SU6000RT4UTFHW
Highlights
6kVA / 6000VA / 5400W on-line double-conversion UPS; 0.9
power factor
208/120V or 240/120V 60Hz output; Economy mode option
6U Rack/Tower installation;
Hot-swappable power and battery modules
USB, RS232 & EPO ports;
SNMP/WEB and contact-closure card options
Front panel LEDs with detailed
LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (3 wire); NEMA
5-15R, 5-15/20R & Hardwire outputs
Description
Tripp Lite SU6000RT4UTFHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers
Package Includes
SU6000RT4UHVPM complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower compatible configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC
Hot-swappable UPS Power
Module output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU
SUPDMB6KHW Detachable
PDU with Maintenance Bypass with manual bypass switch supports hot-swappable UPS power module replacement with no interruption to connected equipment. 4U UPS power module and included 2U low-voltage transformer install in only 6 rack
Switch
SU6000XFMR2U Low voltage spaces total (6U) with a maximum installed depth of only 21.8 in. / 55.3 cm. Maintains full-time sine wave output within 2% of selectable 208/240V and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as transformer
PowerAlert Software CD high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even
1 x 6-ft. USB Cable
1 x 6-ft. Serial Cable when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to
DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic
4 Post Rackmount Hardware (2 sets) distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types.
Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional
SNMP/Web and contact-closure communications card accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network
Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off
(EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input. Hardwire UPS output, plus 1 L6-30R, 8 5-15/20R and 4 5-15R outlets. External battery packs are field replaceable and hot swappable. $250,000
1 / 6
Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Features
Tripp Lite SU6000RT4UTFHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a 6U rack/tower compatible configuration (4U power module plus 2U low-voltage transformer)
Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Detachable back panel PDU contains input line cord connection, output receptacles and manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
Hardwire input (208/240V L1, L2 + G)
Hardwire high and low voltage output, plus 8 5-15/20R and 4 5-15R 120V outlets
Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU6000RT4UTFHW)
Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UTFHW)
Maximum installed rack depth of only 21.8 in. / 55.3 cm
Maintains full-time sine wave output within 2% of selected 208/240V and 120V nominal at 60Hz in double conversion mode
Corrects brownouts to 156V at full load (100V at 50% load or less)
Corrects overvoltages to 290V at full load (300V at 90% load or less)
Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
Network-grade AC surge and noise suppression
Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces
UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD)
Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network
Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations
LED/LCD display panel rotates for viewing in rackmount or tower configurations
Supports Emergency Power Off (EPO) via built-in interface
Battery independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even when batteries areexpired and require replacement
BP192V12-3U external battery packs are field replaceable and hot swappable
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Specifications
2 / 6
OUTPUT
Output Capacity Details
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as the overload is cleared
6000
6.0
5400
5.4
0.9
3:1
120V; 208V; 240V
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)
60 Hz
Output frequency regulation +/- 0.05Hz (free running)
+/- 2%
+/- 10%
+/- 2%
Output Receptacle Details
Output Circuit Breakers
(4) 5-15R; (8) 5-15/20R; (1) L6-30R; Hardwire
Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
Low voltage 20A breakers on the transformer module protect 4 5-15/20R outlets each; Low voltage 15A breakers protect 2 5-15/20R outlets each
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
Nominal Input Voltage(s) Supported 208V AC; 240V AC
Nominal Input Voltage Description Factory configured to 208V
UPS Input Connection Type
UPS Input Connection Description
Recommended Electrical Service
Input Phase
Hardwire
3 wire single phase input (L1, L2, G)
40A (200/208v); 30A (220/230/240v)
Single-Phase
3 / 6
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access
Battery Replacement Description
Expandable Runtime
2 minutes (5400 watts)
8.5 minutes (2700 watts)
Runtime is expandable with external battery packs
BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U
(limit 1)
192
6 hours from 10% to 90% (typical, full load discharge)
RBC5-192
Front panel battery access door
Hot-swappable, user replaceable internal batteries
Yes
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Online, double-conversion power conditioning
Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Switches
Alarm Cancel Operation
Audible Alarm
Front Panel LCD
LED Indicators
Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
Alarm cancel switch
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
No
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
SURGE / NOISE SUPPRESSION
UPS AC Suppression Response
Time
EMI / RFI AC Noise Suppression
Instantaneous
Yes
PHYSICAL
Included Mounting Accessory
Description
4 post rackmount installation accessories included (2 sets)
4 / 6
Installation Form Factors Supported with Optional Accessories
2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate UPS and transformer components
Primary Form Factor Rackmount
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Installed Whole System Maximum
Rack Depth (in.)
Installed Whole System Maximum
Rack Depth (cm)
Rack Height (U Spaces)
UPS Power Module Weight (lbs.)
6.85 x 17.5 x 20.7
17.4 x 44.5 x 52.6
21.8
55.4
6
116.2
52.8
UPS Power Module Weight (kg)
Stepdown Transformer Dimensions
(hwd / in.)
Stepdown Transformer Dimensions
(hwd / cm)
3.5 x 17.5 x 21.8
8.8 x 44.5 x 55.4
Stepdown Transformer Weight (lbs.) 72.6
Stepdown Transformer Weight (kg) 33
UPS Shipping Dimensions (hwd / in.) 22.2 x 23.6 x 29.1
UPS Shipping Dimensions (hwd / cm)
56.4 x 59.9 x 73.9
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
UPS Housing Material
232.1
105.4
Fans
Steel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
AC Economy Mode BTU / Hr. (Full
Load)
AC Mode Efficiency Rating (100%
Load)
765
90%
AC Economy Mode Efficiency Rating
(100% Load)
96%
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
1767
5 / 6
Operating Elevation (ft.)
Audible Noise
Operating Elevation (m)
LINE / BATTERY TRANSFER
Transfer Time
Transfer Time (Economy Mode)
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
0-3000m (0 to 10,000 ft.)
60 dBA at front side 1 meter
0-3000 m
COMMUNICATIONS
Communications Interface
Network Monitoring Port Description
PowerAlert Software
Communications Cable
WatchDog Compatibility
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
Included
USB, DB9 serial and EPO cables included
Yes
No transfer time (0 ms.) in online, double-conversion mode
8ms. typical power failure response in optional economy mode
156V (full load) / 100V (50% load or less, derates linearly)
280V (full load) / 300V (90% load or less)
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module;
Hot swappable batteries
High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications
UPS Certification Details
Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of
Hazardous Substances)
IEC 61000-4-5 1995 B Surge Immunity
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime Insurance
© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
6 / 6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- 6 kVA 5400 W
- 13 AC outlet(s)
- Rackmount Black
Related manuals
Frequently Answers and Questions
What is the output capacity of the Tripp Lite SU6000RT4UTFHW UPS?
What is the power factor of the Tripp Lite SU6000RT4UTFHW UPS?
What is the nominal output voltage of the Tripp Lite SU6000RT4UTFHW UPS?
What is the output frequency regulation of the Tripp Lite SU6000RT4UTFHW UPS?
What type of output waveform does the Tripp Lite SU6000RT4UTFHW UPS produce?
What is the input voltage range of the Tripp Lite SU6000RT4UTFHW UPS?
What type of input connection does the Tripp Lite SU6000RT4UTFHW UPS have?
What is the recommended electrical service for the Tripp Lite SU6000RT4UTFHW UPS?
What is the full load runtime of the Tripp Lite SU6000RT4UTFHW UPS?
advertisement