CompX eLock Manual Programming Guide
Temperature Menu (if equipped)..................................................................................................................................... 4
Turn on/off alarm................................................................................................................................................................ 4
Reset observed temperatures.............................................................................................................................................. 4
Temperature limits............................................................................................................................................................... 4
Alarm settings..................................................................................................................................................................... 5
Log intervals........................................................................................................................................................................ 5
Mute alarm......................................................................................................................................................................... 5
Reset alarm......................................................................................................................................................................... 6
Credential Menu............................................................................................................................................................ 6
Add credential..................................................................................................................................................................... 6
Delete credential................................................................................................................................................................. 6
View credential.................................................................................................................................................................... 7
Edit credential..................................................................................................................................................................... 7
Set/edit a 2nd pin.............................................................................................................................................................. 7
Display Formats.............................................................................................................................................................. 8
Set Date/Time............................................................................................................................................................... 8
Network Test (if equipped).............................................................................................................................................. 8
lcd Contrast.................................................................................................................................................................. 9
lcd Backlight................................................................................................................................................................ 9
Set Beep Volume............................................................................................................................................................ 9
Reset Net Schedule........................................................................................................................................................ 9
Setup Code................................................................................................................................................................... 10
Factory Reset................................................................................................................................................................. 10
Stand-alone & Networked eLock Alarm States................................................................................................................. 10
NOTE:
The Table of Contents contains live
links. Click on any section, and
the corresponding page will load.
CompX eLock® Manual Programming Guide
Table of Contents
continued
Other manuals available as separate pdfs:
w CompX Database & Network Configuration & Installation Manual
w CompX LockView Software Instruction Manual
The following chart is intended
to serve as a guide to provide
the most logical and efficient
set-up of the CompX eLock.
Will the locks
be 802.11
or Ethernet
networked?
Is LockView
Software going
to be used?
CompX
Database
& Network
Configuration
& Installation
Manual
yes
CompX
LockView
Software
Instruction
Manual
CompX eLock®
Manual
Programming
Guide
go to
no
yes
no
go to
CompX eLock®
Manual
Programming
Guide
3
CompX eLock® Manual Programming Guide
Temperature Menu (if equipped)
CompX eLocks equipped with temperature monitoring have a
number of features that can be adjusted in the TEMPERATURE
MENU using manual programming.
Provided the Permission Levels in LockView have not been
changed, the default permissions are as follows:
4. A) TURN ON ALARM will appear if alarm is disabled. Press
“NEXT/SELECT” to enable the alarm. Alarm Now
Enabled will appear.
B) TURN OFF ALARM will appear if alarm already is
enabled. Press “NEXT/SELECT” to disable the alarm.
Alarm Now disabled will appear.
RESET OBSERVED TEMPERATURES
(OBSERVED TEMPERATURES IS THE HIGHEST AND LOWEST TEMPERATURE
THAT HAS BEEN RECORDED SINCE THE LAST TIME THE eLock WAS RESET.
THIS WILL NOT RESET THE UPPER AND LOWER LIMITS FOR ALARMING.
IF THE ALARM TEMPERATURE LIMITS NEED TO BE CHANGED, SEE
TEMPERATURE LIMITS)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP”/“DOWN” button, highlight RESET OBS. TEMPS
and press “NEXT/SELECT.”
5. Reset high and low temperature observations? will appear.
Press ‘UP” and “NEXT/SELECT” to reset.
6. Observations RESET will be displayed.
TEMPERATURE LIMITS
(THE TEMPERATURE RANGE CAN BE ADJUSTED IN 1/10TH DEGREE
INCREMENTS)
Temperature ranges:
Standard Temp eLock: -40°C to 100°C (-40°F to 212°F)
Ultra Low Temp eLock: -100°C to -40°C (-148°F to -40°F)
TURN ON/OFF ALARM
1 Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Using the “UP”/“DOWN” button, highlight TEMPERATURE
MENU and press “NEXT/SELECT.”
4
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP”/“DOWN” button, highlight TEMP LIMITS and
press “NEXT/SELECT.”
5. ALARM SETTINGS will appear along with the current MINIMUM
TEMP & MAXIMUM TEMP settings.
6. Press “UP”/“DOWN” buttons to select value and +/- buttons
or numeric keypad to adjust.
7. Press “NEXT/SELECT” when done.
CompX eLock® Manual Programming Guide
Temperature Menu (if equipped)
continued
ALARM SETTINGS
LOG INTERVALS
(USING ALARM SETTINGS, ALARM VOLUME, ALARM DELAY, ALARM
DURATION and THE CHIRP WARNING CAN BE ADJUSTED)
(The eLock records in memory temperature data that can be
retrieved using LockView. USING LOG INTERVALS, THE FREQUENCY
OF TEMPERATURE RECORDS FOR “IN RANGE” AND “OUT OF RANGE”
MEASUREMENTS CAN BE ADJUSTED)
Note: Supervisor level status is required to Enable/Disable
the alarm using ALARM SETTINGS.
serves two purposes. First, it is an early warning that
the temperature being recorded has gone outside of the
programmed acceptable range. Second, if the temperature
alarm is disabled, the CHIRP feature allows the eLock to
sound an alert.
CHIRP
1.
2.
3.
4.
When CHIRP is “ON” it will sound at the programmed volume
(OFF, SOFT, MED, LOUD) and escalate at the programmed speed
(OFF, SLOW, MED, FAST) until the programmed ALARM DELAY time
has expired and the eLock starts to alarm, or the temperature
goes back in the programmed acceptable range.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP”/“DOWN” button, highlight ALARM SETTINGS
and press “NEXT/SELECT.”
5. Alarm Settings will appear along with CHIRP ON/OFF; CHIRP
VOLUME; CHIRP ESCALATION
6. Press “UP”/“DOWN” buttons to select and +/- buttons or
numeric keypad to adjust:
ALARM VOLUME (OFF, SOFT, MED, LOUD)
ALARM DELAY (MINUTES)
ALARM DURATION (MINUTES)
CHIRP (ON/OFF)
CHIRP VOLUME (OFF, SOFT, MED AND LOUD)
CHIRP ESCALATION (OFF SLOW, MED, FAST)
7. Press “NEXT/SELECT” when done.
5.
Only Supervisors are allowed to adjust LOG INTERVALS.
Press “MENU.” LOGIN PLEASE will be displayed.
Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
Using the “UP / “DOWN” button, highlight LOG INTERVALS
and press “NEXT/SELECT.”
Log Intervals will appear along with WHEN IN-RANGE and WHEN
OUT-OF-RANGE
6. Press “UP”/“DOWN” buttons to select value and +/- buttons
or numeric keypad to adjust.
7. Press “NEXT/SELECT” when done.
MUTE ALARM
(THE ALARM MUST BE TRIGGERED AND THE RECORDED TEMPERATURE
MUST BE OUTSIDE OF THE ACCEPTABLE PROGRAMMED RANGE IN
ORDER TO MAKE USE OF THIS FEATURE)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP / “DOWN” button, highlight MUTE ALARM and
press “NEXT/SELECT.”
5. MUTED TEMPORARILY will flash. Note: THERMAL ALARM
MUTED will be displayed on the main screen.
A) After muting a triggered alarm, if the temperature returns
to the acceptable programmed range within 10 minutes,
THERMAL ALARM MUTED will no longer be displayed.
B) After muting a triggered alarm, if the temperature fails
to return to the acceptable programmed range after 10
minutes, **THERMAL WARNING** will appear and the
programmed Alarm Delay time will start. If this Alarm
Delay time expires and the temperature remains outside
of the acceptable programmed range, the alarm will be
triggered and **THERMAL ALARM** will appear on the
main screen.
Note: Choosing to MUTE an alarm that has already been MUTED will
extend the remaining mute time by another 10 minutes.
5
CompX eLock® Manual Programming Guide
Temperature Menu (if equipped)
RESET ALARM
continued
A) **THERMAL ALARM** will continue to be displayed
indefinitely until the alarm is reset by following the above
RESET ALARM steps.
B) If the temperature does not return to the acceptable
programmed range after 10 minutes, **THERMAL
WARNING** will appear on the main screen.
If the temperature does not return to the acceptable range
within the programmed alarm delay time, the alarm will be
triggered and **THERMAL ALARM** will appear on the
main screen.
(THE ALARM MUST BE TRIGGERED AND THE RECORDED TEMPERATURE
MUST HAVE RETURNED TO THE ACCEPTABLE PROGRAMMED RANGE IN
ORDER TO MAKE USE OF THIS FEATURE)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight TEMPERATURE MENU and
press “NEXT/SELECT.”
4. Using the “UP / “DOWN” button, highlight RESET ALARM and
press “NEXT/SELECT.”
5. ALARM RESET will flash. Note: **THERMAL ALARM** will
no longer be displayed on the main screen.
Credential Menu
ADD CREDENTIAL
Note: There are two status levels; Supervisor and User. Each
eLock can hold any combination of up to 3,000 Supervisors
and Users.
Only Supervisors are allowed to ADD Users and Supervisors.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT.”
4. Highlight ADD CREDENTIAL and press “NEXT/SELECT.”
5. CREDENTIAL TO ADD will be displayed. Scan new credential
or enter new 4-14 digit PIN and Press “ENTER.”
6. Adding credential will be displayed.
7. Default status is User. To change status to Supervisor press
the + button.
8. The new User/Supervisor will be added to the next available
slot number. To change the slot number, press “UP” and
then +/- to move to next available slot; or use the numeric
keypad to enter the desired slot number and press “NEXT/
SELECT.”
9. CREDENTIAL NAME ENTRY will appear. Press 2 - 9 for A - Z;
press 1 for , , + or ; press 0 for “space”; press and hold
0 - 9 for numbers. (Maximum number of allowed characters
is 14.)
10. Press “ENTER” when done. STORED will be displayed when
complete.
-.
6
_
DELETE CREDENTIAL
Note: There are two status levels; Supervisor and User.
1.
2.
3.
4.
5.
6.
7.
8.
Only Supervisors are allowed to DELETE Users and
Supervisors.
Press “MENU.” LOGIN PLEASE will be displayed.
Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
Highlight DELETE CREDENTIAL and press “NEXT/SELECT”
Credential to Delete will be displayed. All of the occupied
slots along with the name (if one exists) will be listed. If
the status of the credential is a supervisor, an asterisk (*)
appears next to the slot number. Press “MENU” to re-sort
by slot number, alphabetically by name, or showing all
supervisors first.
Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by
page to highlight credential to be deleted and press “NEXT/
SELECT.”
Press “UP” and “NEXT/SELECT” to delete. DELETED will be
displayed when complete.
Press “BACK/CANCEL” to return to CREDENTIAL MENU.
CompX eLock® Manual Programming Guide
Credential Menu
VIEW CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to VIEW Users and Supervisors.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight VIEW CREDENTIAL and press “NEXT/SELECT”
5. Credential to View will be displayed. All of the occupied
slots along with the name (if one exists) will be listed. If
the status of the credential is a supervisor, an asterisk (*)
appears next to the slot number. Press “MENU” to re-sort
by slot number, alphabetically by name, or showing all
supervisors first.
6. Press “UP”/“DOWN” to scroll by line or +/- to scroll by
page to highlight credential to be viewed and press “NEXT/
SELECT.”
7. Press “NEXT/SELECT” to display NAME, SLOT NUMBER, LAST
ACCESS ATTEMPT.
8. Press “DOWN” to display CREDENTIAL TYPE (KEYPAD, PROXCARD
continued
5. Credential to Edit will be displayed. All of the occupied
slots along with the name (if one exists) will be listed. If
the status of the credential is a supervisor, an asterisk (*)
appears next to the slot number. Press “MENU” to re-sort
by slot number, alphabetically by name, or showing all
supervisors first.
6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by page
to highlight credential to be edited.
7. Press “NEXT/SELECT” to edit highlighted credential
8. Press +/- to change Level (Supervisor/User); press “UP/
DOWN” to highlight 2nd PIN. To add a new or change an
existing 2nd PIN, enter a 4 - 14 digit number using the
numeric keypad. Press “ENTER” when done. Confirm the
new/changed PIN by entering it again when prompted.
Press “ENTER” when done.
9. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
SET/EDIT YOUR 2nd PIN
Note: There are two status levels; Supervisor and User.
or MAGSTRIPE CARD)
9. Press “DOWN” again to display the ACCESS SCHEDULE
(TIME AND DAY RESTRICTIONS AS SET IN LOCKVIEW).
10. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
EDIT CREDENTIAL
Note: There are two status levels; Supervisor and User.
1.
2.
3.
4.
Only Supervisors are allowed to EDIT Users and Supervisors.
Press “MENU” LOGIN PLEASE will be displayed.
Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
Highlight EDIT CREDENTIAL and press “NEXT/SELECT”
1.
2.
3.
4.
5.
6.
Only Supervisors are allowed to SET/EDIT YOUR 2nd PIN.
The steps below will make the logged in credential a Dual
Credential Supervisor requiring a 2nd PIN.
Follow the EDIT CREDENTIAL steps to add/change dual
credential status for other Supervisors or Users.
Press “MENU” LOGIN PLEASE will be displayed.
Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
Highlight SET YOUR 2nd PIN and press “NEXT/SELECT.”
(EDIT YOUR 2nd PIN will appear if a second PIN credential
already exists)
Type new 2nd PIN will be displayed. Enter new 4 - 14 digit
PIN and press “NEXT/SELECT.”
Type 2nd PIN again will appear. Enter the 4 - 14 digit PIN
again and press “NEXT/SELECT.” NEW PIN SET will appear.
7
CompX eLock® Manual Programming Guide
Display Formats
Using DISPLAY FORMATS, the following can be adjusted:
HOURS: AM/PM or 24 HOUR
M-F/DATE:
w
w
w
w
w
MON-SUN; MM/DD/YY;
MON-SUN; MMM D ‘YY;
MON-SUN; DD-MM-YY;
MON-SUN; DD-MMM-YY
MON-SUN; YYYY-MM-DD
TEMP: °FAHRENHEIT or °CELSIUS
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight DISPLAY FORMATS and
press “NEXT/SELECT.”
4. DISPLAY FORMATTING will be displayed.
5. Press “UP”/“DOWN” buttons to select and +/- buttons to
adjust.
6. Press “NEXT/SELECT” when done.
Set Date/Time
Using SET DATE/TIME, the following can be adjusted:
SETUP TIME ZONE (INCLUDING AUTO DAYLIGHT SAVING)
SET DATE (MONTH, DAY, YEAR)
SET TIME (HOUR, MINUTE, AM/PM)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight SET DATE/TIME and press
“NEXT/SELECT.”
4. DATE/TIME MENU will be displayed.
5. Press “UP”/“DOWN” to scroll and “NEXT/SELECT” to
modify.
6. Press “UP”/“DOWN” buttons to select and +/- buttons to
adjust.
7. Press “NEXT/SELECT” when done.
8. Press “BACK/CANCEL” to return to main menu.
Network Test (if equipped)
Using NETWORK TEST the strength and quality of the eLock
connection to the network is displayed. The IP and MAC
addresses are also shown here.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
8
3. Press “DOWN” button to highlight NETWORK TEST and press
“NEXT/SELECT.”
4. NET STATUS will be displayed as well as Str: & Qual:, IP
address and MAC address.
5. Press “CLEAR” to exit.
CompX eLock® Manual Programming Guide
LCD Contrast
Using LCD CONTRAST, the LCD contrast can be adjusted:
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight LCD CONTRAST and press
“NEXT/SELECT.”
4. LCD Contrast will be displayed.
5. Enter 1 - 9 on numeric keypad or +/- buttons to adjust.
6. Press “NEXT/SELECT” when done.
7. Press “BACK/CANCEL” to return to main menu.
LCD Backlight
Using LCD BACKLIGHT the brightness of the display can be
adjusted.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight LCD BACKLIGHT and
press “NEXT/SELECT.”
4. LCD Backlight will be displayed.
5. Enter 0 - 9 on numeric keypad or +/- buttons to adjust.
(“0” = OFF)
6. Press “NEXT/SELECT” when done.
Set Beep Volume
Using SET BEEP VOLUME, the audible beep can be
adjusted.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight set beep volume and
press “NEXT/SELECT.”
4. Beep Volume will be displayed.
5. Enter 0 - 9 on numeric keypad or +/- buttons to adjust.
(“0” = MUTE)
6. Press “NEXT/SELECT” when done.
7. Press “BACK/CANCEL” to return to main menu.
Reset Net Schedule
A PROPERLY CONFIGURED AND ENABLED NETWORK eLock
IS REQUIRED TO MAKE USE OF THIS FEATURE.
Only Supervisors are allowed to RESET NET SCHED.
Using RESET NET SCHED. the scheduled network check-in
time can be set.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight RESET NET SCHED. and
press “NEXT/SELECT.”
4. NETWORK TIMING RESET will be displayed. The eLock will
follow the programmed or default check-in frequency from
this time of day forward.
For example:
Programmed Update Interval as set in LockView is 12 hours
(twice/day). The time of day was 10 a.m. when the eLock
was initialized.
Therefore, the eLock update time is 10 a.m. and 10 p.m.
The desired update time is 6 a.m. and 6 p.m.
Using the RESET NET SCHED. feature, the above steps
should be followed at 6 a.m. or 6 p.m.
9
CompX eLock® Manual Programming Guide
Setup Code
The eLock is shipped in factory mode. Whenever the eLock
is in this mode, it is considered to be unsecured.
**In order to ensure the security of the application on
which the eLock will be installed, the setup code (supplied
on green sticker set as Setup Cd) must be kept in a safe
location.**
If required, the eLock can be placed in setup mode.
1. Press and Hold “CLEAR” on eLock keypad. ENTER SETUP
CODE will appear.
2. Enter the setup code (supplied on green sticker set as Setup
Cd) and press “ENTER”
3. SETUP CODE will appear in the upper left hand corner
of the eLock LCD. (The eLock will exit setup mode after 5
minutes of inactivity). Press “CLEAR” on the eLock keypad
to exit SETUP mode. READY will be displayed in the upper
left hand corner LCD)
SETUP mode would be necessary in the event that:
1-- Initialization of the eLock - out of the box - was done in the
absence of LockView, and it is now desired to add the eLock
to the database in LockView.
2-- It became necessary to restore the original factory
settings, (FACTORY RESET); disable the Wi-Fi or Ethernet
module, (TURN OFF/ON NETWORK); or disable the eLock
temperature probe, (TURN OFF THERM).
Factory Reset
In the event that it becomes necessary to erase ALL
Supervisors/Users and log entries (access & temperature)
from the eLock and reset all settings to the original factory
defaults, a FACTORY RESET may be performed.
warning: once a Factory Reset is performed, it
cannot be reversed.
1. Press and hold “CLEAR” on the keypad.
2. ENTER SETUP CODE will be displayed. Enter the set up code
and press “NEXT/SELECT.”
3. SETUP will be appear in the upper left hand corner of the
eLock LCD.
4. Press the “MENU” button.
5. Press “UP” button to highlight FACTORY RESET and press
“NEXT/SELECT.”
6. Press “UP” button to highlight FULL RESET.
7. Press and Hold “NEXT/SELECT” to reset.
8. Factory will appear in the upper left hand corner of the
eLock LCD. Note: whenever eLock is in factory mode, it is
considered unsecured.
Stand-alone & Networked eLock Alarm States
The eLock has a total of 5 programmable ALARM/Alert
STATES.
MANUAL for an explanation of the various temp ALARM
SETTINGS)
1) Temperature Outside Limits
(Temperature monitoring eLock is required to make use of
this feature)
Temperature Outside Limits is intended to trigger an
alarm at the eLock if the current temperature exceeds the
programmed low or high limit for more than the programmed
alarm delay time. (See TEMPERATURE MENU & LOCKVIEW
10
(See LockView Manual for SETUP ALERT MESSAGING
explanation)
2) Battery Low
(A properly configured and enabled network eLock is
required to make use of this feature.)
CompX eLock® Manual Programming Guide
Stand-alone & Networked eLock Alarm States continued
Battery Low can be programmed to send an alert(s) via
LockView’s Remote Alert Messaging if the eLock battery
power drops below a defined level.
Note: There is no audible alarm that can be triggered at the eLock,
however there is a yellow LED low battery indicator (LOW BATT) on the
eLock keypad.
Unauthorized Entry is intended to trigger an alarm at
the eLock in the event of an application “break-in.” The
Unauthorized Entry alarm will sound when the door switch
opens and the eLock latch bolt is in the extended position.
The eLock will stop alarming after a valid credential is
presented.
(See LockView Manual for SETUP ALERT MESSAGING
explanation)
(See LockView Manual for SETUP ALERT MESSAGING
explanation)
3) Door Ajar
5) Overdue Network Check-in
(Door switch – NOT INCLUDED – must be installed and
enabled in order to make use of this feature)
(A properly configured and enabled networked eLock is
required to make use of this feature)
Door Ajar is intended to trigger an alarm at the eLock if the
application door has been left opened.
Overdue Network Check-in can be programmed to send an
alert(s) via LockView’s Remote Alert Messaging if the eLock
is X minutes past the programmed scheduled check in
time. The overdue time is programmable in LockView in one
minute increments. The Overdue Network Check-in alert will
be triggered if this time expires before the eLock checks-in
to the network.
After the programmed or default eLock latch open time has
expired, the Door Ajar timer begins. The Door Ajar timer is
programmable in LockView in one second increments. The
door ajar alarm will be triggered if this time expires before
the door switch closes.
The eLock will stop alarming after the door switch closes.
(See LockView Manual for SETUP ALERT MESSAGING
explanation)
Note: There is no audible alarm that can be triggered at the
eLock; however, NETWORK TEST (see page 8) can be used
to determine Wi-Fi strength and quality.
(See LockView Manual for SETUP ALERT MESSAGING
explanation)
4) Unauthorized Entry
(Door switch – NOT INCLUDED – must be installed and
enabled in order to make use of this feature)
11
CompX eLock
Manual
Programming Guide
Copyright 2011 © CompX Security Products / 847.752.2500 / compx.com / 715 Center St., Grayslake, IL 60030
Any companies and/or products referred to herein are marks or registered trademarks of their respective companies, owners and/or mark holders.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement