Alkomat AlcoFind DA-7000, półprzewodnikowy


Add to my manuals
6 Pages

advertisement

Alkomat AlcoFind DA-7000, półprzewodnikowy | Manualzz

Breath Alcohol Tester

Advanced semiconductor sensor

Personal & professional use alcohol tester

DA-7000

Instruction

Manual

Replaceable pre-calibrated sensor module type

4 digit display with backlit LCD

Self-diagnostic function

HADRON

Please read the user's manual carefully before use.

Introduction

Thank you for your purchasing our product.

Alcofind DA-7000 is an ideal solution for the semi-professional and personal use.

It offers 4-digit reliable accuracy by use of an advanced and high-grade semiconductor sensor.

Contents

Digital Breathalyzer

Alcofind DA-7000

2 (two) AA size Batteries

6 (Six) Mouthpieces

Carrying Pouch

User's Manual

Name of Each Part

Mouthpiece

Warning lamp

Display window

START

(Ready to test)

DA-7000

Outlet

MODE

Product Specifications

Indication of B.A.C. 0.00 ~ 4.00

Accuracy

Warm up time

Sensor

Power supply

Battery Life

Within 20 seconds at 0.50

g/l( )

HADRON

Dimensions(W x H x D)

Weight

Calibration

0.00 ~ 2.00mg/l

+/- 0.1 at 1.0 at 25 C

Within 5 seconds at 0.50

g/l( )

Semiconductor Sensor

2 (two) AA size alkaline batteries

Approx. 300 tests

58mm x 123mm x 24mm

114g including batteries every 6 months or after 200 tests

Operating temperature

0.00 ~ 0.40%BAC

0 ~ 40 C

The specifications are subject to change without prior notice for functional improvements.

How To Use

1. Initial Use

Press down the battery cover of the unit to open it and install two AA size 1.5V alkaline batteries paying attention to the battery polarity.

Close the battery cover and insert the mouthpiece to the slot.

2. How to test Breath Alcohol Concentration a) Press the start button and the unit displays the total number of tests

performed for a second and then displays b) Press the start button again and it automatically begins a countdown.

c) When the countdown reaches "0" (zero), then blow through the mouthpiece

for more than 4~5 seconds till you hear a double beep signal. d) Once the sensor has analyzed the breath sample, it displays the estimated

Blood Alcohol Concentration.

(When the unit operates normally)

Indication of

Breath sampling

Error Messages

Breath Analyzing

If there is no breath sample blown within

15 seconds, the LCD will display "OUT".

Press start to restart the countdown cycle and retest.

sample, the LCD will display "FLO". test result

Press start to restart the countdown cycle and retest.

If the battery indicator display is empty, install two new alkaline AA batteries.

3. How to use Flash a) Press the start button and the unit displays the total number of tests performed

for a second and then displays b) Press the mode button and the unit displays that means the flash

will be off after 59.9 minutes automatically.

If you press the start button, the timer will stop and if you press the start button

again, the timer will go on.

c) Whenever you press the mode button, the flash repeats On and Off.

d) Emergency signal function

- When the flash is On, press the start button for 3 seconds and then the

emergency signal operates.

- Press the mode button, if you want to stop the emergency signal.

- If you press the start button, the timer will stop and if you press the start button

again, the timer will go on.

4. How to use Sensor Test Mode a) Press the start button and the unit displays the total number of tests performed

for a second and then displays b) Press and hold the mode button for more than 5 seconds till the unit displays c) Press the start button and the unit displays and the countdown will

commence.

HADRON

When the countdown is finished, the next test should be also performed within

10 seconds in the same way.

The test will be performed 3 times automatically. But if the unit displays FLO or OUT,

press the start button for Re-Test after 5 seconds.

f) The test results will be displayed as follows and you can Re-test 3 ~ 5 times,

if necessary.

Sensor is good.

Recommended to replace the sensor.

Sensor initialization or first self test is finished after purchase.

Required to Re-test, since the data are not stable.

g) If you press the start button, the unit displays

5. How to change Measuring Unit a) Press the start button and the unit displays the total number of tests performed

for a second and then displays b) Press and hold the mode button for more than 5 seconds till the unit

displays

Then, press mode button shortly till it displays

By pressing start button, you can adjust the unit.

HADRON

Important safety information

Allow at least 20 minutes between the last consumption of alcohol and testing.

For more accurate testing, it is recommended to recalibrate the sensor every

6 months or after 200 tests.

For protection of the sensor, avoid direct ray of light, extreme temperature, humid place, keep the device in a well ventilated place and keep out of reach of children.

When not used for a long time, keep the device after taking out the batteries.

In case of reuse after long-term storage, there might be high tolerance of test result for about first 3 tests.

Do NOT leave the device together with newspaper or alcohol containing materials.

Do NOT blow smoke, saliva or other contaminants into the mouthpiece, as the sensor may be damaged.

Do NOT block the air hole apposite to the mouthpiece during the test, as it may damage the sensor.

We recommend you to replace the disposable mouthpiece for sanitary purpose.

Do NOT use the device as a tool to drink and drive. The manufacturer and seller will not take any legal responsibility for the measured test value.

Warranty Card

Product

Purchasing

Date

(DD-MM-YY)

Digital Breathalyzer Alcofind DA-7000

Seller

Shop name

Owner name

The manufacturer warrants the product to be free from defects in workmanship or material (excluding calibration) under normal use either for 1(one) year from date of purchase or 300 breath tests whichever comes earlier. The manufacturer's obligation under this warranty is

Warranty limited to replacing, adjusting or repairing the unit at manufacturer's

Period option, if returned along with proof of purchase.

For any defects due to natural disaster or customer's negligence, misuse, reconstruction and repair by unauthorized person, reasonable cost shall be charged for repair or part replacement.

Customer Service

For any question, after sales service, product calibration or purchasing mouthpiece, please get in contact with the nearest distributor in your country.