Yokogawa TC10 N Temperature Controller Quick Guide
Werbung
Werbung
TEMPERATURE CONTROLLER
Model: TC10 - Quick Guide . IM 05C01E81-01EN
3 rd edition - April 2017
Yokogawa Electric Corporation
2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns
EU Declaration of conformity and Manual retrieval
TC10 is a panel mounting, Class II instrument. It has been designed with compliance to the European Directives. All information about the controller use can be found in the Engineering Manual:
IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN.
The EU Declaration of Conformity and the manual of the controller can be downloaded (free of charge) from the web-site: www.yokogawa.com/ns/tc10/im/
The Authorised Representative for this product in the EEA is:
Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort,
The Netherlands) is the Authorised Representative of
Yokogawa Electric Corporation for this Product in the EEA.
Safety Precautions
The following general safety precautions must be observed during all phases of operation, service and repair of this instrument.
If this instrument is used in a manner not specified in this manual, the protection provided by this instrument may be impaired. Also,
YOKOGAWA Electric Corporation assumes no liability for the customer’s failure to comply with these requirements. The following symbol is used on the instrument.
This manual is an essential part of the product; keep it in a safe place for future reference. This manual is intended for the following personnel:
- Engineers responsible for installation, wiring, and maintenance of the equipment.
- Personnel responsible for normal daily operation of the equipment.
m
WARNING
Calls attention to actions or conditions that could cause serious or fatal injury to the user or damage to the instrument, and indicates precautions that should be taken to prevent such occurrences. The user must refer to the Engineering manual for special instructions.
AC
AC/DC
The equipment wholly protected by double insulation or reinforced insulation.
m
WARNING
- Whenever a failure or a malfunction of the device may cause dangerous situations for persons, things or animals, please remember that the plant must be equipped with additional devices which will guarantee safety.
- We warrant that the products will be free from defects in material and workmanship for 18 months from the date of manufacturing.
Products and components that are subject to wear due to conditions of use, service life and misuse are not covered by this warranty.
Safety, Protection, and Modification of the Product
- In order to protect the system controlled by this product and the product itself, and to ensure safe operation, observe the safety precautions described in the Engineering manual. Use of the instrument in a manner not prescribed herein may compromise the product’s functions and the protection features inherent in the device. We assume no liability for safety, or responsibility for the product’s quality, performance or functionality should users fail to observe these instructions when operating the product.
- Installation of protection and/or safety circuits with respect to a lightning protector; protective equipment for the system controlled by the product and the product itself; foolproof or failsafe design of a process or line using the system controlled by the product or the product itself; and/or the design and installation of other protective and safety circuits are to be appropriately implemented as the customer deems necessary.
- This product is not designed or manufactured to be used in critical applications that directly affect or threaten human lives. Such applications include nuclear power equipment, devices using radioactivity, railway facilities, aviation equipment, air navigation facilities, aviation facilities, and medical equipment. If so used, it is the user’s responsibility to include in the system additional equipment and devices that ensure personnel safety.
- Modification of the product is strictly prohibited.
- This product is intended to be handled by skilled/trained personnel for electric devices.
m
WARNING
- This instrument is for Measurement Category No. 1. Do not use it for measurements in locations falling under Measurement Categories No. 2, No. 3 and No. 4.
IV
Internal wiring
III O T
Outlet
II
No. EN 61010-2-030
No. 1 O (Other)
No. 2 Measurement
Category II
No. 3 Measurement
Category III
No. 4 Measurement
Category IV
Description
For measurements performed on circuits not directly connected to MAINS.
For measurements performed on circuits directly connected to the low-voltage installation.
For measurements performed in the building installation.
For measurements performed at the source of the low-voltage installation.
How to Connect Wires m
WARNING
- Wiring work must be carried out by a person with basic electrical knowledge and practical experience.
- Be sure to turn OFF the power supply to the controller before wiring to avoid an electric shock. Use a tester or similar device to ensure that no power is being supplied to a cable to be connected.
- As a safety measure, always install a circuit breaker (an IEC 60947 compatible product, 5 A, 100 V or 220 V AC) in an easily accessible location near the instrument. Moreover, provide indication that the switch is a device for turning off the power to the instrument.
- Install the power cable keeping a distance of more than 1 cm from other signal wires.
- The power cable is required to meet the IEC standards concerned or the requirements of the area in which the instrument is being installed.
- Wiring should be installed to conform to NEC (National Electrical
Code: ANSI/NFPA-70) or the wiring construction standards in countries or regions where wiring will be installed.
- For control relay output, alarm relay output, and power terminal connections, use heat-resistant cables.
- Recommended tightening torque: 0.5 Nm.
Model and suffix codes
Model Code
TC10
Fixed code -N
Suffix codes
-N o C o o o D o F
Power supply
L
H
Fixed code C
R N N
OUT1 - 3
IN/OUT4(Fixed code)
Serial communication
Fixed code
Option Code
R R R
V N N
V R R
V V R
A R R
D
S
N
F
Description
Temperature Controller
Always "-N"
24 VAC/DC (Custom order)
100 to 240 VAC
Always "C"
Relay output for ON/OFF control
Relay output with 2 alarm relays, for ON/OFF or Heat/Cool control with 1 alarm
DC Output for SSR
DC Output for SSR with 2 alarm relays or DCV and Relay output for
Heat/Cool control with 1 alarm
2 DCV outputs for SSR with 1 Relay
(Custom order)
Analog output with 2 alarm Relays, or analog output and Relay output for Heat/Cool control with 1 alarm
Always "D" - Selectable I/O (logic input / 12 V SSR drive output / 12VDC
20 mA transmitter power supply
RS485 Modbus
None
Always “F”
/GK Panel gasket for IP65
HOW TO SET THE CONFIGURATION CODE
PV
AT
DISPLAY AND KEYS
Unit
(°C/°F)
Alarm active
Manual mode
Output
LEDs
ELECTRICAL CONNECTIONS
PV
4 to 20 mA
2 wire transmitter
PV
PV
Operator Mode
Access to:
- Operator Commands
(Timer, Setpoint selection ...)
- Parameters
- Configuration
Access to:
- Operator additional information
(Output value, running time ...)
Access to:
- Set Point
Programmable key:
Start the programmed function
(Autotune, Auto/Man, Timer ...)
RS485
12 VDC
(note)
4 to 20 mA
3 wire transmitter
DI2 (note)
AT
Increase the displayed value or select the next element of the parameters list
Decrease the displayed value or select the previous element
Exit from Operator commands/Parameter setting/Configuration
Analogue input mV, V
12 VDC
(note) mA
Process Value
(in eng. units)
Autotune in progress
(flashing)
Set Point
(auto mode)
Output Value
(manual mode)
Param. value or
State/Function
(Editing mode)
Editing Mode
Confirm and go to
Next parameter
Pt1000
Thermocouple
Pt100
CONFIGURATION CODE
The TC10-N can be easily configured by the “Code Configuration” method for the most common requirements, just entering two 4-digit codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions.
For complete controller configuration see the Engineering Manual.
Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed:
L M N O c%d1
User c%d1 L M N O
DIMENSIONS
Overall dimensions (L x H x D): 48 x 48 x 73 mm
(1.89 x 1.89 x 2.87 in.)
Panel Cut-out (L x H): 45 +0.6
x 45 +0.6
mm
(1.78
+0.023
x 1.78
+0.023
in.)
MOUNTING
2
1
1
3
2
45 +0.6
1.78
mm
+0.023
in
Mounting requirements
This instrument is intended for permanent installation, for indoor use only, in an electrical panel which encloses the rear housing, exposed terminals and wiring on the back.
Select a mounting location having the following characteristics:
1. It should be easily accessible;
2. There is minimum vibrations and no impact;
3. There are no corrosive gases;
4. There are no water or other fluids (i.e. condensation);
5. The ambient temperature is in accordance with the operative temperature (0 to 50°C);
6. The relative humidity is in accordance with the instrument specifications (20 to 85%);
The instrument can be mounted on panel with a maximum thickness of 8 mm.
When the maximum front protection (IP65) is desired, the optional gasket must be mounted.
OP1
OP2
OP4
(note)
OP3
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 16;
- 0 to 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 16;
- 12 Vdc (20 mA) transmitter power supply connecting the 2 wire transmitter between terminals 4 and 1; for 3 wire transmitter connect terminal 4 to transmitter power supply input and terminal 1 and 2 to transmitter signal output.
ALARM TYPES (Cod2 digits: P, Q, R)
PV
DI1
65 mm min.
2.56 in min.
TERMINALS
Pin connector q 1.4 mm max.
(0.055 in.)
L
Stripped wire
L: 5.5 mm
(0.21 in.)
Line
Neutral
100 to 240 Vac/
20 to 30 Vdc/
18 to 28 Vac
Absolute Alarm
65 mm min. 2.56 in min.
Time
Press for 3 seconds to access the configuration mode
Press and to enter the configuration
Password 4
(default 300)
Press and to enter c%d1
(Input Type and
Control Mode)
Press and to enter c%d2 (Alarms and
Service Functions)
PV
PV
PV
PV
AT
AT
AT
AT
Press to store the
Configuration code
Note: To leave the Configuration session without
saving the settings made, press the button
Input Type and Range
TC J
TC K
TC S
TC R
TC T
PT 100
PT 1000
Linear 0 to 60 mV
-50 to +1000°C
-50 to +1370°C
-50 to 1760°C
-50 to +1760°C
-70 to +400°C
-200 to +850°C
-200 to +850°C
Linear 12 to 60 mV
Linear 0 to 20 mA (this selection forces Out 4 = TX)
Linear 4 to 20 mA (this selection forces Out 4 = TX)
Linear 0 to 5 V
Linear 1 to 5 V
Linear 0 to 10 V
Linear 2 to 10 V
TC J
TC K
TC S
-58 to +1832°F
-58 to +2498°F
-58 to 3200°F
TC R
TC T
PT 100
PT 1000
-58 to +3200°F
-94 to +752°F
-328 to +1562°F
-328 to +1562°F
P Q R S
User c%d2
Alarm 3
Alarm 2
Alarm 1
Not used
Sensor break
Absolute
Absolute High/Low
Deviation
Band
High
Low
External High/Low
Internal High/Low
Deviation high
Deviation low
External band
Internal band
5
6
7
8
9
2
3
4
P
0
1
Q c%d2
P Q R S
R
5
6
7
8
9
2
3
4
0
1
5
6
7
8
9
2
3
4
0
1
L
0
0
0
0
0
0
0
0
1
1
1
1
1
2
2
1
2
2
1
1
1
1
M
8
9
4
7
2
3
0
1
2
3
4
0
1
1
4
9
0
5
7
8
5
6
Control mode
ON/OFF heating = H
ON/OFF cooling = C
ON/OFF with neutral zone
(H/C)
PID heating = H
PID cooling = C
PID double action (H/C)
OP4
AL3
C
H
H
AL3
H
AL3
H
AL3
C
AL3
C
H
H
AL3
C
AL3
C
AL3
C
OP3
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
AL2
OP2
H
H
AL1
C
AL1
AL1
AL1
AL1
AL1
AL1
C
AL1
AL1
AL1
C
AL1
H
H
AL1
C
OP1
C
NU
C
NU
H
NU
H
NU
C
NU
H
H
C
NU
H
H
C
NU
C
NU
Note: As default, when the alarms are active, only AL1 threshold is available at “ Operator Command” level to perform non critical tasks. To protect the AL2 and AL3 thresholds against undesired changes, they are available only at “ Parameters
list” level (password: 20). For different configurations, see the Engineering Manual.
N
0
1
1
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
O
9
0
1
6
7
8
3
4
5
0
1
2
5
6
7
8
9
2
3
4
Service functions activation
None
Wattmeter (instantaneous power expressed in kW) (note 1)
Wattmeter (Power consuption expressed in kWh/h) (note 2)
Absolute worked time (expressed in days) (note 3)
Absolute worked time (expressed in hours) (note 3)
Notes: 1. Wattmeter Instantaneous power is continuously computed as multiplication of the Load Voltage, Load Current parameter values and the controller output instantaneous value.
2. Wattmeter power consumption is the estimated hourly energy consumption (using Load Voltage and Load Current parameter values), computed on the previous 15 minutes period. The readout is updated every 15 minutes.
3. Worked Time counter is continuously increased when the controller is turned ON.
S
2
3
4
0
1
Absolute
High
Absolute
Low
Absolute
External
Absolute
Internal
Deviation
High
Deviation
Low
Band
Internal
Band
External
PV
PV
PV
ON
ON
ON
ON
ON
Absolute High-Low Alarm
ON
ON
Deviation Alarm
ON
ON
Band Alarm
ON
ON
Time
ON
Time
ON
ON
Time
ON
PARAMETERS SETTING
Press the key for 3 seconds
To Code configuration
mode (cod1, cod2 tables on the front page)
CONTROLLER OPERATION
Press the key for 3 s
Heating
248.0
H035
Cooling
248.0
C045
Output Value %
(e.g. heating = 35%, cooling = 45%)
Increase value
Decrease value
Power (kW) or Energy (Wh)
Parameters setting
Confirm and go to
Next parameter
Increase the displayed value or select the next element
Decrease the displayed value or select the previous element
To exit the parameter setting procedure press the key (for 3 s) or wait until the timeout expiration
(about 30 seconds).
248.0
U854
Worked time (days)
Set Point Change
sp
250.0
Changed operative
Set Point
Start
Dot flashes while the
Auto-tune is in progress
Depending on
Cod2 digit S setting
248.0
d854
Worked time (hours)
248.0
h854
If active
To return to the Normal Mode, press the key for 3 seconds or wait for the 10s timeout sp
248.0
Operative
Set Point
248.0
tunE
Auto-tune started
Password 4
(default: 300)
248.0.
248.0
Auto-tune in progress
Note: The key could be assigned by the user to other functions using the Usrb parameter setting a.sp
1
Active
Set Point selection
Confirm/Next
Password 2
(default: 20)
Additional Information
Access to parameters
Press the key (3 s) or wait for the 10s time out to store the new Set Point and return to Normal Mode
EVOTUNE is a fast and fully automatic procedure that can be started in any condition, regardless the deviation from SP.
The controller selects automatically the best tune method and computes the optimum PID parameters.
Confirm/Next
Back to the first parameter
AL1
If AL1 is active
250
Confirm/Next
To return to the Normal Mode, press the key for 3 seconds or wait for the 10s timeout
Parameters List (PASS: 20)
(Parameters of RS485 Modbus Serial Communications are shown in gray cells in the below table)
Group Param.
Description Range value or selection list elements Default
User value
Note
Commands
Control oPEr Operative Mode Selection a.sp
Set Point Selection tune Start Auto Tune
Pb Proportional Band ti
Integral Time td Derivative Time
HSEt Hysteresis ON/OFF Control tc.H
Heating output cycle time rcg tcc
Relative Cooling Gain
Cooling output cycle time reg = Auto; oplo = Manual; stdy = Standby
0 = SP, 1 = SP2, 2 = SP3, 3 = SP4
0 = oFF, 1 = start
1 to 9999 (Engineering Units = E.U.)
0 to 10000 s
0 to 1000 s
0 to 9999 (E.U.)
0.1 to 130 s
0.01 to 99.99
0.1 to 130 s
0 = SP
0 = OFF
20
200
1
50
20.0
1.00
20.0
evoTUNE
Cod1 Digit N = 1
Cod1 Digit N = 0
Cod1 Digit N = 1
Cod1 Digit N = 1
Cod1 Digit O > 4
Cod1 Digit N = 1
Cod1 Digit O > 1
Set Point
Alarms
Soft Start
Input
I/O
Digital
Inputs
SP Set Point 1
SP2 Set Point 2
SP3 Set Point 3
SP4 Set Point 4
-1999 to +9999 (E.U.)
-1999 to +9999 (E.U.)
SPLL Set Point min. Value -1999 to SPHL (E.U.)
SPHL Set Point max. Value nSP No. of Set Points
SPLL to 9999 (E.U.)
1 to 4 1
AL1 Alarm 1 threshold AL1L to AL1H al1l Alarm 1 low threshold/Low limit al1H Alarm 1 high threshold/High limit
-1999 to +9999 (E.U.)
-1999
9999
HAL1 AL1 hysteresis
AL2
Alarm 2 threshold
1 to 9999 (E.U.)
AL2L to AL2H
1 al2l Alarm 2 low threshold/Low limit al2H Alarm 2 high threshold/High limit
-1999 to +9999 (E.U.)
HAL2 AL2 hysteresis
AL3
Alarm 3 threshold
1 to 9999 (E.U.)
AL3L to AL3H diF.2 Digital Input 2 Function
1
-1999
9999 al3l Alarm 3 low threshold/Low limit al3H Alarm 3 high threshold/High limit
-1999 to +9999 (E.U.)
1 to 9999 (E.U.) HAL3 AL3 hysteresis stp
Soft Start Output value
Sst Soft Start Time ssc
Low Scale readout fsc High Scale readout dP
Number of decimals
FiL Measured value Digital filter
-100 to 100%
0.00 to 8.00 (hh.mm)
-1999 to 9999
-1999 to 9999
0 to 3 (linear inputs); 0 to 1 (other inputs) 0
OFF; 0.1 to 20.0 s
1
-1999
9999
0
0
-1999
9999
0 = OFF io4.F I/O 4 Function diF.1 Digital Input 1 Function
ON = Transmitter Power Supply;
OUT4 = SSR out;
Di2C = Dig. In. from contact;
Di2U = 24 VDC Digital Input;
0 to 21
ON
0
0 to 21 0 di.A
Digital Inputs Action usrb Key di.cl
Colour of the Process Value display
Function
0 = DI1 direct action, DI2 direct action;
1 = DI1 reverse action, DI2 direct action;
2 = DI1 direct action, DI2 reverse action;
3 = DI1 reverse action, DI2 reverse action.
nonE, tunE, oplo, aac, asi, chsp, st.by, str.t
0 = Change
1 = Red
2 = Green
3 = Orange
2
0 tunE
Display ade
Display change color threshold
(when di.Cl = 0)
0 (OFF) to 9999 (e.u.)
Serial communications dis.t Display Power OFF time (mm.ss) oFF (display ON) 0.1 to 99.59
Add
Instrument Address bAud Baud rate
1 to 254 1 oFF
1200, 2400, 9600 baud, 19.2, 38.4 kbaud 9600
Wattmeter
Uolt Load Voltage cur Load Current
1 to 999 (V)
1 to 9999 (A)
230
0 to 999 300
Password
PAS4 Configuration access Password
PAS2 Parameters access Password 0 to 999 20
If nSP > 1
If nSP > 2
If nSP > 3
If digit P of
Cod2 is > 1
If digit Q of
Cod2 is > 1
If digit R of
Cod2 is > 1
For linear Input types only
See the DI1, DI2 functions table
DI2 only if configured
See the Key function table
If Change, the colour is green if PV differs from SP less than Ade, red if higher than Ade and orange if is lower than Ade
Modbus RTU slave protocol
If digit S of
Cod2 is > 1
Note: To access all the instrument features, please see the “Complete configuration procedure” in the “Engineering Manual”.
Operator Command
If more than
1 Set Point active
(nsp > 1) sp
248.0
Increase
Decrease
Confirm/Next nsp > 1 sp2
120.0
nsp > 2 sp3
225.0
1 st SP value change nsp > 3 sp4
340.0
dif$ Digital Inputs DI1 and DI2 Functions
Code displayed
0
Description
Disabled (OFF) (default)
1
2
Alarm Reset
Alarm Acknowledge (ACK)
3 Hold of the measured value
4 Stand by mode
5
6
Manual Mode
Heat with “SP” and CooL with “SP2”
7 to 17
Reserved
18
19
Sequential Set Point selection [on transition]
SP/SP2 selection
20
21
Binary coding for Set Point selection on DI1 and DI2
(00 = SP, 01 = SP2, 10 = SP3, 11 = SP4)
Digital inputs in parallel to the UP and Down keys
(DI1 = UP key, DI2 = DOWN key) usrb Key
Function
Code displayed nonE tune oplo
Description
Not used
Starts auto tuning functions (default)
Manual mode aac asi
Alarm Reset
Alarm Acknowledge chsp st.by
Circular Set Point Selection (shows SP, SP2, SP3)
Stand-by mode
关于产品污染防止管理
Control of Pollution Caused by the Product
根据中华人民共和国电子信息产品的防污染管理办法,对本仪表进行说明。
This is an explanation for the product based on “Control of pollution caused by Electronic Information Products” in the People’s Republic of China.
产品中有毒有害物质或元素的名称及含量
部件名称
铅(Pb) 汞(Hg)
有毒有害物质或元素
镉(Cd)
框架(塑料)
框架(金属)
内部接线材料
电源
×
×
×
×
×
×
×
×
×
×
×
×
○:表示该部件所有基材中所含的有毒有害物质含量均未超过GB/T26572标准中规定的限量要求。
×:表示该部件中至少有一种基材中所含的有毒有害物质含量超过GB/T26572标准所规定的限量要求。
六价铬(Cr6+)
×
×
×
×
多溴联苯(PBB)
○
○
○
○
多溴二苯醚(PBDB)
○
○
○
○
该标志为环境保护使用期限,根据SJ/T11364,适用于在中国(台湾、香港、澳门除外)销售的电子电气产品。
只要遵守该产品的安全及使用注意事项,从产品生产之日起至该标志所示年限内,不会因为产品中的有害物质外泄或突变而导致环境污染或对人身财产产生重大影响。
注释) 该标志所示年限为“环境保护使用期限”,并非产品的保质期。另外,关于更换部件的推荐更换周期,请参阅使用说明书。
DISPOSAL
The appliance (or the product) must be disposed of separately in compliance with the local standards in force on waste disposal.
Herunterladen