Allen-Bradley
DriveTools32™
Getting Started
Version 1.xx
Using RSLinx™ Lite
Version 1.7
Getting Started
Manual
Important User
Information
Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to
assure that each application and use meets all performance and safety
requirements, including any applicable laws, regulations, codes and standards.
The illustrations, charts, sample programs and layout examples shown in
this guide are intended solely for purposes of example. Since there are
many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability (to
include intellectual property liability) for actual use based upon the
examples shown in this publication.
Rockwell Automation publication SGI-1.1, Safety Guidelines for the
Application, Installation, and Maintenance of Solid-State Control (available from your local Rockwell Automation office), describes some
important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole or
in part, without written permission of Rockwell Automation, is prohibited.
Throughout this manual we use notes to make you aware of safety considerations:
!
ATTENTION: Identifies information about practices
or circumstances that can lead to personal injury or
death, property damage or economic loss.
Attention statements help you to:
•
Identify a hazard.
•
Avoid the hazard.
•
Recognize the consequences.
Important: Identifies information that is critical for successful application and understanding of the product.
Summary of Changes
Summary of Changes
The information below summarizes the changes to the company-wide templates
since the last release.
Updated
Information
Publication 9303-5.13 – March 1998
No changes have been made to this manual.
Notes:
Publication 9303-5.13 – March 1998
Table of Contents
Preface
Who Should Use This Manual? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-1
What Is DriveTools32? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-1
What Is RSLinx? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-2
DriveTools32 Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-2
Purpose of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-3
Contents of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-3
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-4
Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-4
Conventions Used in this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-4
Rockwell Automation Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-5
Local Product Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-5
Technical Product Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P-5
Overview
Chapter 1
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
What Hardware Do I Need to Run DriveTools32 and RSLinx?. . . . . . . . . . . . 1-1
Using DriveTools32 with an Allen-Bradley
SCANport-Compatible Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Using DriveTools32 with a 1336T (FORCE) Drive . . . . . . . . . . . . . . . . . . . 1-4
Using DriveTools32 with a 1395 Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Example Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
DriveTools32 and Database Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Installing DriveTools32 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Installing RSLinx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
Starting RSLinx and DriveTools32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Setting Up an RS-232
Point-to-Point Serial
Communications
System for a
SCANport Product
Chapter 2
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
What Is an RS-232 Point-to-Point Serial Communications System? . . . . . . . 2-1
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Configuring RSLinx for RS-232 Point-to-Point Serial Communications . . . . . 2-3
Configuring the Communication Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Mapping the Configured Driver(s) to the KTPort Value. . . . . . . . . . . . . . . . 2-5
Setting the Communication Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Using the WHO Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Publication 9303-5.13 – March 1998
ii
Table of Contents
Setting up an RS-232
Point-to-Point Serial
Communications
System for a 1395
Drive
Chapter 3
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What is an RS-232 Point-to-Point Serial
Communications System for a 1395 Drive? . . . . . . . . . . . . . . . . . . . . . . .
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disabling RSLinx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Communication Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up DH+
Direct
Communications
Systems
Chapter 4
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
What is a DH+ Direct Communications System? . . . . . . . . . . . . . . . . . . . . . 4-1
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Configuring RSLinx for DH+ Direct Communications . . . . . . . . . . . . . . . . . . 4-2
Configuring the Communication Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Mapping the Configured Drive(s) to the KTPort Value . . . . . . . . . . . . . . . 4-4
Setting the Communication Information for DH+ Direct. . . . . . . . . . . . . . . . . 4-5
Configuring RSLinx for DF1 (KF2) to DH+ Communications. . . . . . . . . . . . . 4-6
Configuring the Communication Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Mapping the Configured Driver(s) to the KTPort Value . . . . . . . . . . . . . . . 4-8
Setting the Communication Information for DF1(KF2) to DH+ . . . . . . . . . . . 4-9
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Using the WHO Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Setting Up a DH+ to
RIO Block Transfer
Pass Thru
Communications
System
Chapter 5
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What is a DH+ to RIO Block Transfer Pass Thru
Communications System?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring RSLinx for DH+ to RIO Block Transfer
Pass Thru Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the Communication Driver . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mapping the Configured Driver(s) to the KTPort Value . . . . . . . . . . . . . . .
Setting the Communication Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the WHO Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Publication 9303-5.13 – March 1998
3-1
3-1
3-2
3-2
3-3
3-4
5-1
5-1
5-3
5-3
5-3
5-4
5-5
5-6
5-7
5-8
Table of Contents
iii
Setting Up a
ControlNet Direct
Communications
System
Chapter 6
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
What is a ControlNet Communications System? . . . . . . . . . . . . . . . . . . . . . . 6-1
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Configuring RSLinx for ControlNet Direct Communications . . . . . . . . . . . . . . 6-2
Configuring the Communication Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Mapping the Configured Driver(s) to the KTPort Value. . . . . . . . . . . . . . . . 6-4
Setting the Communication Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Using the WHO Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Setting Up an AllenBradley Ethernet to
RIO Block Transfer
Pass Thru
Communications
System
Chapter 7
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
What is an Ethernet Communications System? . . . . . . . . . . . . . . . . . . . . . . . 7-1
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Configuring RSLinx for Ethernet to
RIO Block Transfer Pass Thru Communications . . . . . . . . . . . . . . . . . . . . 7-3
Configuring the Communication Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Setting the Communication Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
Using RSLinx
Gateways
Chapter 8
Chapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
What is a Gateway? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
Checking Your Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Configuring RSLinx for RSLinx Gateways . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Configuring the Communication Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Testing the Configured Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
Mapping the Configured Driver(s) to the KTPort Value. . . . . . . . . . . . . . . . 8-4
Setting the Communication Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
Connecting to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Using the WHO Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
SCANportCompatible
Products Supported
by DriveTools32
Appendix A
Appendix Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Supported SCANport-Compatible Database Files . . . . . . . . . . . . . . . . . . . . .A-1
DriveTools32 and Database Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-2
Publication 9303-5.13 – March 1998
iv
Notes:
Publication 9303-5.13 – March 1998
Table of Contents
Preface
Preface
Read this preface to become familiar with the rest of the manual. This preface
covers the following topics:
Who Should Use
This Manual?
•
Who should use this manual.
•
An overview of the DriveTools32 software package.
•
An overview of RSLinx software.
•
DriveTools32 compatibility.
•
The purpose of this manual.
•
Terms and abbreviations.
•
Conventions used in this manual.
•
Rockwell Automation support.
Use this manual if you are responsible for using the DriveTools32 software to
program, monitor, and troubleshoot Allen-Bradley AC and DC digital drive
products. You should be familiar with programming Allen-Bradley digital drives
and have basic personal computer and Windows operation skills and knowledge,
such as starting applications, navigating between applications, using menus and
dialogs, and accessing your Windows help system.
!
What Is
DriveTools32?
ATTENTION: Only people familiar with Allen-Bradley
drives and the associated machinery the drives control should plan
or implement the installation, start up, and subsequent
maintenance of the drive. Failure to comply may result in personal
injury and/or equipment damage.
The DriveTools32 software is a Microsoft Windows-based family of software
products that let you program, monitor, and troubleshoot Allen-Bradley AC and
DC digital drive products. Some of the software products in the DriveTools32
family also support communication with PLC controls through the DH+
network.
Publication 9303-5.13 – March 1998
P-2
Preface
ATTENTION: Hazard of injury exists. The Start/Stop/Jog
functions of DrivePanel32 software rely on the integrity of
software and communication with the drive. A malfunction in any
process may cause loss of control and inability to stop the drive.
An independent hardwired Stop device MUST be within your
reach when using DrivePanel32 software to control the drive.
DrivePanel32 software is designed to be a temporary control
alternative during setup. DrivePanel32 software is not a substitute
for primary operator controls that meet industry standards and
local codes.
!
The following software products are part of the DriveTools32 family:
This product:
What Is RSLinx?
Lets you:
DriveManager32
Easily create and edit drive data tables that are used to configure the
drive for your application. DriveManager32 also provides several
methods of displaying drive diagnostic information.
DriveMonitor32
Graphically monitor a drive and/or PLC controller data points when
connected to a Data Highway Plus (DH+) network. You can easily
display live data values in a graphic format.
DrivePanel32
Use the programming and control functions available with a Human
Interface Module (HIM) from your terminal screen. DrivePanel32
includes several additional programming and control features that are
not available with a HIM.
DriveTrending32
Program the internal drive trending functions when supported by the
drive.
DriveBlockEditor32
Create and monitor function block programs that run internally on drives
that support function blocks.
RSLinx provides the necessary communications drivers which enable
DriveTools32 to communicate with Allen-Bradley drive products using a variety
of different networks as well as direct serial connection.
Before you can start DriveTools32 applications, you must either load RSLinx
Lite (version 1.7), which is shipped with DriveTools32, or you must already
have RSLinx running and properly configured on your PC.
DriveTools32
Compatibility
Publication 9303-5.13 – March 1998
DriveTools32 is a 32-bit application designed to be used with Microsoft
Windows 95 or Microsoft Windows NT (4.0 or greater).
Preface
Purpose of this
Manual
P-3
This manual is designed to get you started using DriveTools32 software. You
will learn how to set up and properly configure RSLinx for your system and how
to connect to your drive from a DriveTools32 application.
The DriveTools32 software family contains online help designed to let you
understand and use this product.
Important: You should read this manual and be familiar with your drive system
before you install and set up your DriveTools32 software.
Contents of this Manual
This manual contains the following information:
Chapter
Title
Contents
Preface
Describes the purpose, background, and scope of this manual as well as an overview
of this product.
1
Overview
Provides an overview of the DriveTools32 software, an overview of the types of
communications you can use, an explanation of this manual’s structure, instructions
for installing DriveTools32, instructions for installing RSLinx, and a description of
databases used by DriveTools32.
2
Setting Up an RS-232 Point-toPoint Serial Communications
System for a SCANport Product
Provides information for properly configuring RSLinx for an RS-232 point-to-point
serial communications system as well as the steps for connecting to the drive from
within DriveTools32 applications.
3
Setting Up an RS-232 Point-toPoint Serial Communications
System for a 1395 Drive
Provides information for disabling RSLinx and properly configuring DriveTools32 for a
1395 RS-232 point-to-point serial communications system as well as the steps for
connecting to the drive from within DriveTools32 applications.
4
Setting Up DH+ Direct
Communications Systems
Provides information for properly configuring RSLinx for DH+ Direct communications
systems as well as the steps for connecting to the drive from within DriveTools32
applications.
5
Setting Up a DH+ to RIO Block
Transfer Pass Thru
Communications System
Provides information for properly configuring RSLinx for a DH+ to RIO Block Transfer
Pass Thru communications system as well as the steps for connecting to the drive
from within DriveTools32 applications.
6
Setting Up a ControlNet Direct
Communications System
Provides information for properly configuring RSLinx for a ControlNet Direct
communications system as well as the steps for connecting to the drive from within
DriveTools32 applications.
7
Setting Up an Allen-Bradley
Ethernet to RIO Block Transfer
Pass Thru Communications
System
Provides information for properly configuring RSLinx for an A-B Ethernet to RIO Pass
Thru communications system as well as the steps for connecting to the drive from
within DriveTools32 applications.
8
Using RSLinx Gateways
Provides information for properly configuring RSLinx for RSLinx gateways as well as
the steps for connecting to the drive from within DriveTools32 applications.
Publication 9303-5.13 – March 1998
P-4
Preface
Related Documentation
See the online help files for individual application information. All
documentation for Drive Tools32 is currently in the online help.
!
ATTENTION: Hazard of injury or death exists when starting
or stopping the drive using DrivePanel32. Do not use
DrivePanel32 until you have read and understood the hazards
explained in your Drive’s User Manual(s).
Terms and
Abbreviations
For a complete listing of Allen-Bradley terminology, including terms and
abbreviations used in this manual, refer to the Allen-Bradley Industrial
Automation Glossary.
Conventions Used
in this Manual
The following conventions are used throughout this manual:
•
Bulleted lists provide information, not procedural steps.
•
Numbered lists provide sequential steps or hierarchical information.
•
Italic type is used for chapter names.
•
Bold type is used for names of dialog boxes, dialog box fields, menus,
menu options, and buttons.
•
When RSLinx is referred to in this manual, you may use either the RSLinx
Lite (version 1.7) shipped with DriveTools32 or RSLinx (version 1.7).
Important: This type of paragraph contains tips or notes that have been added to
call attention to useful information.
Publication 9303-5.13 – March 1998
Preface
Rockwell
Automation
Support
P-5
Rockwell Automation offers support services worldwide, with over 75 sales/
support offices, over 500 authorized distributors, over 250 authorized systems
integrators located through the United States alone, and Rockwell Automation
representatives in every major country in the world.
Local Product Support
Contact your local Rockwell Automation representative for:
•
Sales and order support.
•
Product technical training.
•
Warranty support.
•
Support service agreements.
Technical Product Assistance
If you need to contact Rockwell Automation for technical assistance, please
review the information in this manual and the online help first. If you still have
problems, then call your local Rockwell Automation representative.
Refer to http://www.ab.com for any updates and supporting documentation.
Publication 9303-5.13 – March 1998
P-6
Notes:
Publication 9303-5.13 – March 1998
Preface
Chapter
1
Overview
Chapter Objectives
What Hardware Do
I Need to Run
DriveTools32 and
RSLinx?
Chapter 1 provides an overview of the DriveTools32 software package. This
chapter covers the following topics:
•
An overview of the types of communications systems and required
equipment for each.
•
An explanation of databases DriveTools32 uses and creates.
•
Instructions for installing DriveTools32.
•
Instructions for installing RSLinx.
•
Instructions for starting RSLinx and DriveTools32 applications.
DriveTools32 and RSLinx allow for flexibility when it comes to connecting to
drive products. The hardware you need depends on your drive and your drive
system. This section provides information about some of the more common
configurations.
Important: DriveMonitor32 cannot use RIO Block Transfer Pass Thru
communications or 1395 Serial communications.
Before determining the configuration that you want to use, you should have a
basic understanding of the different communication types that DriveTools32
supports:
Publication 9303-5.13 – March 1998
1-2
Overview
This communication type:
Chapter
RS-232 Point-to-Point Serial for a SCANport-Compatible Drive
2
RS-232 Point-to-Point Serial for a 1395 Drive
3
DH+ Direct
4
DH+ to RIO Block Transfer Pass Thru
5
ControlNet Direct
6
Ethernet to RIO Block Transfer Pass Thru
7
RSLinx Gateway
8
To set up your communications system, you need to:
Publication 9303-5.13 – March 1998
1.
Install DriveTools32 and RSLinx. Refer to instructions later in this chapter.
2.
Determine which configuration most closely matches your system, and
refer to the chapter which represents that configuration for information on
hardware and system configuration.
Overview
1-3
Using DriveTools32 with an Allen-Bradley SCANport-Compatible Product
You can use DriveTools32 with a number of Allen-Bradley SCANportcompatible products, including a 1305 Micro, 1336E (IMPACT), 1336F (PLUS
II), 1336G (Fibers), 1336S (PLUS), 1336T (FORCE), 1557 (Med. Volt), 1394
Servo, or SMC drive. For a list of Allen-Bradley SCANport-compatible
products, refer to Appendix A. If you use DriveTools32 with one of these
products, you have the following options:
To use this
communication type:
You need this
hardware
on the drive-side:
And this hardware
on the PC-side:
For installation,
refer to:
RS-232 Point-to-Point
Serial
1203-GD2 or
1203-GK2 and
appropriate cable,
or 1336-GM2
RS232 port
Chapter 2
DH+ to RIO Block
Transfer Pass Thru
1203-GD1 or
1203-GK1 and
appropriate cable,
or 1336-GM1
1784-KTx, -KL, -PCMK
Chapter 5
Ethernet to RIO Block
Transfer Pass Thru
1203-GD1 or
1203-GK1 and
appropriate cable,
or 1336-GM1
Ethernet Interface
Running TCP/IP
Chapter 7
RSLinx Gateway
Server DH+ to RIO
Block Transfer Pass
Thru
1203-GD1 or
1203-GK1 and
appropriate cable,
or 1336-GM1
Client: Ethernet
Interface Running
TCP/IP
Server: Ethernet
Interface Running
TCP/IP and 1784-KTx,
-KL, or -PCMK
Chapter 8
Publication 9303-5.13 – March 1998
1-4
Overview
Using DriveTools32 with a 1336T (FORCE) Drive
The 1336T (FORCE) drive is a SCANport-compatible product that can use all
options listed above. In addition, it offers the following options:
Publication 9303-5.13 – March 1998
To use
this communication
type:
You need this
hardware
on the drive-side:
And this hardware
on the PC-side:
For installation,
refer to:
RS-232 Serial to DH+
Direct
PLC Communications
Adapter Board
(1336T-GT1EN)
RS232 port and
1770-KF2
Chapter 4
DH+ Direct
PLC Communications
Adapter Board
(1336T-GT1EN)
1784 -KTx, -KL, PCMK
Chapter 4
DH+ to RIO Block
Transfer Pass Thru
PLC Communications
Adapter Board
(1336T-GT1EN)
1784-KTx, -KL, -PCMK
Chapter 5
ControlNet Direct
ControlNet Adapter
Board (1336T-GT3EN),
ControlNet Repeater
Adapter (1786-RPA),
and ControlNet Fiber
Module (1786-RPFM)
KTC, KTC(X)
Chapter 6
Ethernet to RIO Block
Transfer Pass Thru
PLC Communications
Board (1336T-GT1EN)
Ethernet Interface
Running TCP/IP
Chapter 7
RSLinx Gateway
Server: Ethernet to
DH+ Direct
PLC Communications
Adapter Board
(1336T-GT1EN)
Client: Ethernet
Interface Running
TCP/IP
Server: Ethernet
Interface Running
TCP/IP and 1784-KTx,
-KL, or -PCMK
Chapter 8
RSLinx Gateway
Server: Ethernet to
DH+ to RIO Block
Transfer Pass Thru
PLC Communications
Adapter Board
(1336T-GT1EN)
Client: Ethernet
Interface Running
TCP/IP
Server: Ethernet
Interface Running
TCP/IP and 1784-KTx,
-KL, or -PCMK
Chapter 8
Overview
1-5
Using DriveTools32 with a 1395 Drive
If you plan to use DriveTools32 with a 1395 drive, you have the following
options:
To use this
communication type:
You need this
hardware
on the drive-side:
And this hardware
on the PC-side:
For installation,
refer to:
RS-232 Point-to-Point
Serial
1300-ITSSC
RS232 port
Chapter 3
RS-232 Serial to DH+
Direct
Multi-Communications
Adapter Board
(1395-KP51)
RS232 port and
1770-KF2
Chapter 4
DH+ Direct
Multi-Communications
Adapter Board
(1395-KP51)
1784 -KTx, -KL, or
-PCMK
Chapter 4
DH+ to RIO Block
Transfer Pass Thru
Node Adapter
(1395-KP50) or
Multi-Communications
Adapter (1395-KP51)
1784-KTx, -KL, or
-PCMK
Chapter 5
Ethernet to RIO Block
Transfer Pass Thru
Node Adapter
(1395-KP50) or
Multi-Communications
Adapter (1395-KP51)
Ethernet Interface
Running TCP/IP
Chapter 7
RSLinx Gateway
Server: Ethernet to
DH+ Direct
Multi-Communications
Adapter (1395-KP51)
Client: Ethernet
Interface Running
TCP/IP
Server: Ethernet
Interface Running
TCP/IP and 1784-KTx,
-KL, or -PCMK
Chapter 8
RSLinx Gateway
Server: Ethernet to
DH+ to RIO Block
Transfer Pass Thru
Node Adapter
(1395-KP50) or
Multi-Communications
Adapter (1395-KP51)
Client: Ethernet
Interface Running
TCP/IP
Server: Ethernet
Interface Running
TCP/IP and 1784-KTx,
-KL, or -PCMK
Chapter 8
Publication 9303-5.13 – March 1998
1-6
Overview
Example
Configurations
The following figures show some example configurations.
Figure 1.1
RS-232 Point-to-Point Communications for a 1395 Drive
Point-to-Point
Serial Connection
RS232/RS422
1395 Protocol
RS232
Serial Port
RS232
1395 Protocol
RS232
1395
1300-ITSSC
RS422
Figure 1.2
RS-232 Point-to-Point Communications for a SCANport-Compatible Product
Point-to Point
Serial Connection
RS232/DF1
RS232
DF1 Point-to-Point
Protocol
RS232
DF1
RS232
SCANport
GD2
GM2
GK2
SCANport
SCANport
Product
Publication 9303-5.13 – March 1998
Important: For a list of SCANport products,
refer to Appendix A.
Overview
1-7
Figure 1.3
DH+ Direct and RIO Block Transfer Pass Thru Networks
PLC-5
Multi-Point
Serial Connection
DH+
KT, KL,
PCMK
RS232
DH+
RS232
1770-KF2
DF1
DH+
DH+
RIO
Or
Or
GD1
RIO
GM1
SCANport GK1
RIO
DH+
PLC Comm
Adapter
RIO
DH+
Multi-Comm
Adapter
SCANport
1336T
(FORCE)
SCANport
1395
SCANport
Product
Important: For a list of SCANport products,
refer to Appendix A.
Publication 9303-5.13 – March 1998
1-8
Overview
Figure 1.4
ControlNet Direct Communications Network
PLC-5 (C)
ControlNet
Connection
KTC,
KTC(X)
ControlNet
ControlNet
Repeater
1786-RPA
Fiber
Module
1786-RPFM
CNet
ControlNet
Adapter
1336T
(FORCE)
Publication 9303-5.13 – March 1998
Overview
1-9
Figure 1.5
Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications System
PLC-5 (E)
Ethernet Connection
Ethernet
TCP/IP
Ethernet
Ethernet
RIO
Or ENet RIO BT
Pass Thru
Or
GD1
RIO
GM1
SCANport GK1
RIO
DH+
PLC Comm
Adapter
RIO
DH+
Multi-Comm
Adapter
SCANport
1336T
(FORCE)
SCANport
1395
SCANport
Product
Important: For a list of SCANport products,
refer to Appendix A.
Publication 9303-5.13 – March 1998
1-10
Overview
Figure 1.6
RSLinx Gateway Ethernet to DH+ RIO Block Transfer Pass Thru Connection
PLC-5
Gateway
Connection
Server
Client
DH+
Ethernet
DH+
RIO
Or RIO BT
Pass Thru
Or
GD1
RIO
GM1
SCANport GK1
RIO
RIO
DH+
DH+
Multi-Comm
Adapter
PLC Comm
Adapter
SCANport
SCANport
1395
1336T
(FORCE)
DriveTools32 and
Database Files
SCANport
Product
Important: For a list of SCANport products,
refer to Appendix A.
DriveTools32 uses a unique database file for each drive product so that you can
configure each drive individually. DriveTools32 ships with many of the database
files it will need (refer to Appendix A).
If you connect to a drive for which DriveTools32 does not have a database file,
you will be prompted to upload a new database. Click OK and DriveTools32
uploads a database which you can then configure.
Installing
DriveTools32
Software
To install the DriveTools32 software, you need to:
1.
Exit all Windows programs.
2.
Insert the DriveTools32 CD in your CD-ROM drive.
The program automatically displays the Setup Status window to let you
know that it is preparing the InstallShield wizard to help guide you through
the installation. Once the InstallShield wizard program is ready, you are
placed in the setup script.
Publication 9303-5.13 – March 1998
Overview
1-11
3.
Click the appropriate button.
Click:
To:
Next
Indicate that all Windows programs are closed and you are ready to begin the
installation.
Cancel
1. Quit the setup program. The setup script prompts you to make sure
that you really want to cancel the setup script.
2. Close any programs you have running.
3. Go back to step 2.
4.
After reading the DriveTools32 software license agreement, click the
appropriate button.
If you:
Then click:
Accept the terms of agreement
Yes.The readme.txt file will appear.
(Recommended)
Do not accept the terms of agreement
No. The set up procedure will
close.
5.
After carefully reading the information in the readme.txt file, click the
appropriate button.
To:
Click:
Continue installing DriveTools32
Yes
Cancel the installation
No
Go back to the previous dialog box
Back
6.
In the Registration dialog box, enter your name, company, and the
DriveTools32 serial number, and then click Next.
Important: The serial number is located on the DriveTools32 box.
7.
Choose where you want to install DriveTools32.
To:
Click:
Install DriveTools32 in the directory listed
Next (Recommended)
Install DriveTools32 in a different directory
Browse and use the menu structure to locate the
directory
Cancel the setup script
Cancel
Publication 9303-5.13 – March 1998
1-12
Overview
8.
Select the type of setup you want to perform.
If you want to perform:
Click:
The default setup procedure. We recommend that you use this
option as it sets up DriveTools32 in the most typically used
configuration.
Typical (Recommended)
A space-saving installation. Installs only those files necessary to
run the DriveTools32 applications.
Compact
A custom installation. You can customize all available set up
options. Use this option only if you are an advanced user or if you
are a system administrator and your system requires that you
modify the default DriveTools32 configuration.
Custom
9.
Select whether to enable a security system.
DriveTools32 provides a security system that lets the system administrator
decide who can access the system and the type of access those users may
have. For more information about the security system, refer to the
DriveManager32 online help.
!
ATTENTION: This is a one time decision. DriveTools32 must
be re-installed to change security. During a reinstallation, data
may be lost.
If you want to:
Click:
Enable the security system. You will need to log in to the system
later using the default user name of ADMIN and the default
password of PASS.
Yes
Disable the security system.
No
10. Accept the default folder name or select another folder.
The setup script creates a folder in the directory that you specified to
contain the DriveTools32 software. You need to select the name of this
folder. Use either the Select list or enter the name in the field. Click Next
when finished.
Publication 9303-5.13 – March 1998
Overview
1-13
11. Review your setup information.
If you want to:
Click:
Begin copying the files
Next.
Change information
Back. You can continue using the Back button until you reach the
information that you wish to change.
Exit the setup script
Cancel
Depending on the files transferred to your PC during installation, the
following window may appear.
12. Click OK. Your system will restart.
Installing RSLinx
After you install DriveTools32, the RSLinx InstallShield wizard program
appears automatically. You must have RSLinx installed and properly configured
before you can use DriveTools32.
Important: If you already have RSLinx (version 1.7) installed on your PC, do
not install RSLinx Lite. Click Cancel and then Exit Setup.
Important: If the RSLinx InstallShield wizard does not appear automatically,
you can start it in Windows Explorer. Start Windows Explorer, click your
CD-ROM drive, DriveTools32, RSLinx, V1.7, Disk1, and then setup.exe.
Publication 9303-5.13 – March 1998
1-14
Overview
If you need to install RSLinx Lite, follow the instructions in the InstallShield
wizard.
Starting RSLinx
and DriveTools32
To start RSLinx, click Start, Programs, Rockwell Software, RSLinx, and
then RSLinx.
To start DriveTools32 applications, click Start, Programs, DriveTools32 and
then the DriveTools32 application (e.g., DriveManager32).
Important: When you start a DriveTools32 application, RSLinx will
automatically start with it.
Publication 9303-5.13 – March 1998
Chapter
2
Setting Up an RS-232 Point-to-Point Serial
Communications System for a SCANport Product
Chapter Objectives
What Is an RS-232
Point-to-Point
Serial
Communications
System?
RS232
This chapter provides information for configuring an RS-232 point-to-point
serial communications system to a SCANport-compatible product. After
finishing this chapter, you will be able to perform the following tasks:
•
Check your hardware installation.
•
Configure RSLinx for serial communications.
•
Enter information into the DriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
An RS-232 point-to-point serial communications system establishes a direct
serial connection between your PC and your drive. The following is an example
of this type of configuration:
Figure 2.1
RS-232 Point-to-Point Serial Communications for a SCANport-Compatible Product
DF1 Point-to Point
Protocol
RS232
DF1
GD2/GM2/GK2
RS232
SCANport
SCANport
SCANport
Product
Important: Certain DriveTools32 applications may require communication
capacities greater than an RS-232 connection can provide. You may experience
communication faults when using a serial connection.
For this type of configuration, you can have any drive, except a 1395. For
information on setting up an RS-232 point-to-point serial communications
system for a 1395 drive, refer to Chapter 3.
Publication 9303-5.13 – March 1998
2-2
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
Checking Your
Hardware
Installation
Before configuring RSLinx for an RS-232 point-to-point serial communications
and running DriveTools32, you should check your hardware installation. You
should:
•
Make sure that your drive is properly installed and grounded.
•
Check that your cables are all firmly connected.
•
Use a straight-through serial cable (not a null modem).
•
Check your serial communications module settings.
To ensure the serial communications module is correctly installed, you need
to follow the instructions provided with it. For further information on the
1203-GD2, 1203-GK2, or 1336-GM2 communications modules, refer to
publication 1203-5.5.
In most cases, you should use the factory-set defaults. If you decide to
change the default settings, note the new settings because you will use them
later.
For any change to take effect, you must remove and then re-apply power to your
communications module.
Important: If you want to detect a loss of serial communications in
DrivePanel32, you need to set the GD2 Timeout value to a value just large
enough to avoid nuisance faults during normal operation. To set the GD2
Timeout value, select Set GD2 Message Timeout option from the Options
menu in DrivePanel32.
!
Publication 9303-5.13 – March 1998
ATTENTION: Hazard of injury exists. The Start/Stop/Jog
functions of DrivePanel32 software rely on the integrity of
software and communication with the drive. A malfunction in any
process may cause loss of control and inability to stop the drive.
An independent hardwired Stop device MUST be within your
reach when using DrivePanel32 software to control the drive.
DrivePanel32 software is designed to be a temporary control
alternative during setup. DrivePanel32 software is not a substitute
for primary operator controls that meet industry standards and
local codes.
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
Configuring
RSLinx for RS-232
Point-to-Point
Serial
Communications
2-3
To use RSLinx for an RS-232 point-to-point serial communications system, you
need to:
1.
Configure the communication driver.
2.
Test the configured driver.
3.
Map the configured driver(s) to the KTPort Value.
Configuring the Communication Driver
To configure the communication driver, you need to:
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure Drivers. The
Configure Drivers dialog box appears.
Publication 9303-5.13 – March 1998
2-4
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
3.
Double-click RS-232 DF1 Devices. The Configure Allen-Bradley DF1
Communications Device dialog box appears.
4.
Verify the information is correct.
Important: In the Comm Port field, you must enter the number of the Comm
Port with which you intend to use DriveTools32.
Important: In the Station Number field, you must enter the station number that
matches the GD2 module’s address.
5.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Publication 9303-5.13 – March 1998
Close the Configure Drivers dialog box.
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
2.
2-5
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
3.
Close the SuperWho window when you are finished.
Mapping the Configured Driver(s) to the KTPort Value
To map the configured driver(s) to the KTPort value, you need to:
1.
From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.
2.
Choose an unused KT:0 field to map the DF1 device to.
Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped the DF1 device. Enter the number in the
Enter mapping KT(X) Port # to use field in the Communication Setup dialog
box.
3.
Use the drop box for the field to map the configured driver to the port.
4.
Click OK or Apply.
Publication 9303-5.13 – March 1998
2-6
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
Setting the
Communication
Information
You need to provide DriveTools32 with some information that it needs to
establish a connection between your PC and your drive. To do this, you need to:
1.
Start the DriveManager32 application.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select Serial.
4.
In Communications Type field, select RS-232/RS-485 SCANport Pointto-Point.
5.
In the Enter mapping KT Port # field, enter the value of the KT:0 port
used for DF1 communication in the Configure Client Applications dialog
box.
6.
In the Enter Serial Port Com # field, enter the number of the PC serial
communications port that is being used. Valid port numbers are 1, 2, 3,
and 4.
Important: You must use the same serial port number for which RSLinx is
configured. To view the serial port settings on your PC, use the Ports function in
the Windows Control Panel application.
Publication 9303-5.13 – March 1998
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
Connecting to the
Drive
2-7
7.
In the Enter Comm Port Baud Rate field, enter the baud rate that your
communications module and port are using. You can choose 2400, 4800,
9600, or 19200 baud.
8.
If applicable, select 1336T Two Word Header (used ONLY for 1336T
version 0.10).
9.
Click OK.
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The SCANport Network
Connect to Drive dialog box appears.
2.
In the Enter SCANport Adapter Station (0-77:Oct) Field, enter the
SCANport adapter station number. Valid station numbers are between 0 and
77.
Important: You can use the WHO button to determine the station number. The
WHO button is covered in further detail below.
3.
Click OK.
After a short pause, either the DriveManager32 screen with the drive parameters
appears, or you are prompted to create a database.
Publication 9303-5.13 – March 1998
2-8
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
Using the WHO
Button
The WHO button is located on the ScanPort Network Connect to Drive dialog
box to help you determine the station number for your drive. When you click the
WHO button, the WHO’s Active dialog box scans the SCANport list and
displays the devices that are currently active. The following is an example of a
WHO’s Active dialog box.
To select a device:
1.
Highlight the device.
2.
Click OK.
The station number of the device that you select is used for the Enter the
SCANport Adapter Station (0-77 :OCT) field on the SCANport Network
Connect to Drive dialog box.
When you are using serial communications, the WHO’s Active dialog box takes
a few moments to complete the scan.
The main window displayed in the WHO’s Active dialog box shows the
information read from the network WHO command. The information consists of
the following:
This field:
Publication 9303-5.13 – March 1998
Specifies:
Station #
The network station number for each device on the network.
Device Type
The type of device that is associated with the network station number.
Station Name
The textual description contained in the device at the network station number.
Comm. Device
The communication device type as it is identified on the network.
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
2-9
The WHO’s Active dialog box provides the following buttons:
•
SCAN
Click SCAN to rescan the network to read station information.
•
KT Port x
Lets you select an alternate RSLinx KT:0 communication driver. For
RS-232 serial communications, this setting must match your RSLinx DF1
port settings.
Publication 9303-5.13 – March 1998
2-10
Setting Up an RS-232 Point-to-Point Serial Communications System for a SCANport Product
Notes:
Publication 9303-5.13 – March 1998
Chapter
3
Setting up an RS-232 Point-to-Point Serial
Communications System for a 1395 Drive
Chapter Objectives
This chapter provides information for configuring an RS-232 point-to-point
serial communications system for a 1395 drive. After you finish reading this
chapter, you will be able to perform the following tasks:
•
Check your hardware installation.
•
Disable RSLinx if it is using your PC’s communications serial port.
•
Enter information into the DriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
Important: The Control Panel controls in DrivePanel32 are disabled when
communicating with a 1395 drive.
Important: DriveMonitor32 cannot use 1395 serial communications.
What is an
RS-232 Point-toPoint Serial
Communications
System for a 1395
Drive?
An RS-232 point-to-point serial communications system for a 1395 drive
establishes a direct serial connection between your PC and your 1395 drive. An
example of this type of configuration is shown in Figure 3.1.
Figure 3.1
1395 RS-232 Point-to-Point Serial Communications
Point-to-Point
Serial Connection
RS232/RS422
1395 Protocol
RS232
RS232
1395 Protocol
1300-ITSSC
RS232
Serial port
RS422
1395
Publication 9303-5.13 – March 1998
3-2
Setting up an RS-232 Point-to-Point Serial Communications System for a 1395 Drive
Checking Your
Hardware
Installation
Disabling RSLinx
Publication 9303-5.13 – March 1998
Before running DriveTools32, check to make sure that all cable connections
between the drive and the PC are secure. Specifically, you should check that the
following cables are firmly plugged in:
•
The cable between the 1395 drive and the 1300-ITSSC communications
module.
•
The cable between the 1300-ITSSC communications module and your PC.
Before starting DriveTools32, you must make sure RSLinx is disabled for the
communications port you intend to use. To disable it, follow these instructions:
1.
Start RSLinx.
2.
From the Communications menu, select Configure drivers. The
Configure Drivers dialog box appears.
3.
If a configured driver using the communications port is running, select it in
the Configured Drivers list. If no configured driver is running, go to step 5.
4.
Click Delete. The driver is removed from the Configured Drivers list.
5.
Close the Configure Drivers dialog box.
Setting up an RS-232 Point-to-Point Serial Communications System for a 1395 Drive
Setting the
Communication
Information
3-3
To provide DriveTools32 with some information that it needs to establish a
connection between your PC and your drive, you need to:
1.
Start DriveManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select Serial.
4.
In the Communications Type section, select 1395 RS-232.
5.
In the Enter Serial Port Com # field, enter the number of the PC serial
communications port that is being used. Valid port numbers are 1, 2, 3,
and 4.
Important: You must use the same serial port number that your PC is set to. To
view the serial port settings on your PC, use the Ports function in the Windows
Control Panel application.
6.
In the Enter Comm Port Baud Rate field, enter the baud rate that your
communications port uses. You can choose either 2400 or 4800 baud.
7.
In the DTR Pulse Delay (0 to calculate automatically) field, enter 0.
Publication 9303-5.13 – March 1998
3-4
Setting up an RS-232 Point-to-Point Serial Communications System for a 1395 Drive
Important: If your PC’s transmission is too fast for the 1300-ITSSC adapter,
you will have to increase the value for DTR Pulse Delay. Start at 1000 and
increase the value by increments of 500 until communications work.
8.
In the DTR Pulse Width (0 to calculate automatically) field, enter 0.
Important: If your PC’s transmission is too fast for the 1300-ITSSC adapter,
you will have to increase the value for DTR Pulse Width. Start at 50 and
increase the value by increments of 10 until communications work.
9.
Connecting to the
Drive
Click OK.
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The Serial Connect to
Drive dialog box appears.
2.
Click OK.
After a short pause, either the DriveManager32 screen with the drive
parameters appears, or you are prompted to create a database.
Publication 9303-5.13 – March 1998
Chapter
4
Setting Up DH+ Direct Communications Systems
Chapter Objectives
This chapter provides information for configuring a DH+ direct communication
system. After you finish reading this chapter, you will be able to perform the
following tasks:
What is a DH+
Direct
Communications
System?
•
Check your hardware installation.
•
Configure RSLinx for DH+ direct communications.
•
Enter information into the DriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
A Data Highway Plus (DH+) system lets your PC communicate directly with
drives that are connected to the DH+ network using either an internal PC card
(such as a 1784-KT, -KL, or -PCMK) or an external RS232 or DH+ converter
module (such as a 1770-KF2). Figure 4.1 shows an example of a DH+ direct
communication system.
Figure 4.1
DH+ Direct Network
Multi-Point
Serial Connection
DH+
KT, KL,
PCMK
DH+
Or
RS232
1770-KF2
RS232
DF1
DH+
DH+
Or
RIO
DH+
PLC Comm
Adapter
RIO
DH+
Multi-Comm
Adapter
SCANport
1336T
(FORCE)
1395
Publication 9303-5.13 – March 1998
4-2
Checking Your
Hardware
Installation
Configuring
RSLinx for DH+
Direct
Communications
Setting Up DH+ Direct Communications Systems
Before configuring RSLinx and running DriveTools32, you should check:
•
All the cable connections between the drive and the PC are secure.
•
Equipment is powered up.
To use RSLinx for a DH+ communications system, you need to:
1.
Configure the communication driver.
2.
Test the configured driver.
3.
Map the configured driver(s) to the KTPort Value.
Configuring the Communication Driver
To configure the communication driver, you need to:
Publication 9303-5.13 – March 1998
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure Drivers. The
Configure Drivers dialog box appears.
Setting Up DH+ Direct Communications Systems
4-3
3.
Double-click on 1784-KT/KTX(D)/PCMK/PKTX(D). The Configure
Allen-Bradley 1784-KTX/KTXD dialog box appears.
4.
In the Value field, select the correct DH+ device for your configuration.
5.
In the Property box, change any fields as required to match the settings
needed for your DH+ interface card.
6.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Close the Configure Drivers dialog box.
2.
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
3.
Close the SuperWho window when you are finished.
Publication 9303-5.13 – March 1998
4-4
Setting Up DH+ Direct Communications Systems
Mapping the Configured Drive(s) to the KTPort Value
To map the configured driver(s) to the KTPort value, you need to:
1.
From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.
2.
Choose an unused KT:0 field to map the DH+ device to.
Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped your DH+ device. Enter this number in the
Enter mapping KT(X) Port # to use field in the Communication Setup dialog
box.
Publication 9303-5.13 – March 1998
3.
Use the drop box for the field to map the configured driver to the port.
4.
Click OK or Apply.
Setting Up DH+ Direct Communications Systems
Setting the
Communication
Information for
DH+ Direct
4-5
You need to provide DriveTools32 with some information that it needs to
establish a connection between your PC and your drive. To do this, you need to:
1.
Start DriveManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select Data Highway Plus (DH+).
4.
In the Communications Type section, select Data Highway Plus (DH+).
5.
In the Enter mapping KT(x) Port # to use field, enter the KT Port number.
Important: The KT(x) port number must match the RSLinx KT:0 Port number
for DH+ device in the Configure Client Applications dialog box.
6.
If applicable, select 1336T Two Word Head (used ONLY for 1336T
version 0.10).
7.
Click OK.
Publication 9303-5.13 – March 1998
4-6
Configuring
RSLinx for DF1
(KF2) to DH+
Communications
Setting Up DH+ Direct Communications Systems
To use RSLinx for DF1 (KF2) to DH+ communications system, you need to:
1.
Configure the communication driver.
2.
Test the configured driver.
3.
Map the configured driver(s) to the KTPort Value.
Configuring the Communication Driver
To configure the communication driver, you need to:
Publication 9303-5.13 – March 1998
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure Drivers. The
Configure Drivers dialog box appears.
3.
Double-click RS-232 DF1 Devices. The Configure Allen-Bradley DF1
Communications Device dialog box appears.
Setting Up DH+ Direct Communications Systems
4.
4-7
Verify the information is correct.
Important: In the Comm Port field, you must enter the number of the Comm
Port with which you intend to use DriveTooles32.
Important: In the Station Number field, you must enter the station number that
matches the GD2 module’s address.
5.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Close the Configure Drivers dialog box.
2.
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
Publication 9303-5.13 – March 1998
4-8
Setting Up DH+ Direct Communications Systems
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
3.
Close the SuperWho window when you are finished.
Mapping the Configured Driver(s) to the KTPort Value
To map the configured driver(s) to the KTPort value, you need to:
1.
From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.
2.
Choose an unused KT:0 field to map the DF1 device to.
Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped the DF1 device. Enter the number in the
Enter mapping KT(X) Port # to use field in the Communication Setup dialog
box.
Publication 9303-5.13 – March 1998
3.
Use the drop box for the field to map the configured driver to the port.
4.
Click OK or Apply.
Setting Up DH+ Direct Communications Systems
Setting the
Communication
Information for
DF1(KF2) to DH+
4-9
You need to provide DriveTools32 with some information that it needs to
establish a connection between your PC and your drive. To do this, you need to:
1.
Start DriveManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select Data Highway Plus (DH+).
4.
In the Communications Type section, select DF1 (KF2) To Data
Highway Plus (DH+).
5.
In the Enter mapping Port # to use FOR DF1 drivers field, enter the
KT:0 Port number.
Important: The port number must match the RSLinx KT:0 Port number for the
DF1 device in the Configure Client Applications dialog box.
6.
In the Enter Serial Port Com # field, enter the number of the PC serial
communications port that is being used.
7.
In the Enter Comm Port Baud Rate field, enter the baud rate that your
communications module and port are using. You can choose 2400, 4800,
9600, or 19200 baud.
Publication 9303-5.13 – March 1998
4-10
Connecting to the
Drive
Setting Up DH+ Direct Communications Systems
8.
If applicable, select 1336T Two Word Head (used ONLY for 1336T
version 0.10).
9.
Click OK.
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The DH+ Network
Connect to Drive dialog box appears.
2.
Enter the DH+ station number. The DH+ station number is the DH+ address
for the drive. Valid station numbers are octal values between 0 and 77.
Important: You can use the WHO button to determine the station number. The
WHO button is covered in further detail below.
3.
Click OK.
After a short pause, either the DriveManager32 screen with the drive parameters
appears, or you are prompted to create a database.
Publication 9303-5.13 – March 1998
Setting Up DH+ Direct Communications Systems
Using the WHO
Button
4-11
The WHO button is located on the DH+ Network Connect to Drive dialog box
to help you determine the station number for your drive. When you click WHO,
the WHO’s Active dialog box scans the DH+ Network and displays the devices
that are currently active. The following is an example of a WHO’s Active dialog
box.
To select a device:
1.
Highlight the device.
2.
Click OK.
The station number of the device that you selected is used for the Enter DH+
(0-77 :Octal) field on the DH+ Network Connect to Drive dialog box.
The main window displayed in the WHO’s Active dialog box shows the
information read from the network WHO command. The information consists of
the following:
This field:
Specifies:
Station #
The network station number for each device on the network.
Device Type
The type of device that is associated with the network station number.
Station Name
The textual description contained in the device at the network station number.
The Bulletin 1395 drive does not support a network station name. Therefore, the
name shown on the network map is the same for all 1395 drives.
Comm. Device
The communication device type as it is identified on the network.
Publication 9303-5.13 – March 1998
4-12
Setting Up DH+ Direct Communications Systems
The WHO’s Active dialog box provides the following buttons:
•
SCAN
Click on the SCAN button to rescan the network to read station
information.
•
KT Port x
The KT Port radio buttons let you change the currently selected DH+
network KT card from within the WHO’s Active dialog box. When you
change the KT port definition, the dialog rescans the network based on the
new setting.
Publication 9303-5.13 – March 1998
Chapter
5
Setting Up a DH+ to RIO Block Transfer Pass Thru
Communications System
Chapter Objectives
What is a DH+ to
RIO Block Transfer
Pass Thru
Communications
System?
This chapter provides information for configuring a communication system that
uses DH+ to Remote I/O (RIO) Block Transfer Pass Thru. After you finish
reading this chapter, you will be able to perform the following tasks:
•
Check your hardware installation.
•
Configure RSLinx for DH+ to RIO Block Transfer Pass Thru
communications.
•
Enter information into the DriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
A Data Highway Plus (DH+) to RIO Block Transfer Pass Thru communications
system lets your PC communicate with drive products using the PLC-5 RIO
Block Transfer Pass Thru mechanism.
Important: A DH+ to RIO Block Transfer Pass Thru communications system
also works with an SLC-500 family processor using a Series B 1747-SN RIO
scanner in slot 1.
The RIO Block Transfer Pass Thru mechanism requires that a drive be
connected to a PLC-5 as an RIO device on the PLC’s RIO network. You can
connect a drive as an RIO device using several different hardware options
depending on the drive type. These options include:
This drive:
Requires that you use the hardware option:
1395
Node adapter (1395-KP50) or
multi-communications adapter (1395-KP51)
SCANport-Compatible Products
1203 Remote I/O Communications Module
(1203-GD1, 1203-GK1, or 1336-GM1)
1336 (FORCE)
PLC Communications Adapter Board
(1336T-GT1EN) or 1203 Remote I/O
Communications Module (1203-GD1, 1203-GK1,
or 1336-GM1)
Publication 9303-5.13 – March 1998
5-2
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
To communicate with a drive over RIO, you need to set the drive’s RIO adapter
up so that it appears to be an adapter to a PLC RIO scanner. To do this, you need
to specify the rack and group number where the drive is to appear on the RIO
network. You will do this during the Connecting to the Drive step. You should
refer to the documentation for your drive and the communications module for
information on configuring the drive as an RIO device.
Figure 5.1 shows an example of a DH+ to RIO Block Transfer Pass Thru
communications system.
Figure 5.1
DH+ to RIO Block Transfer Pass Thru Network
Multi-Point
Serial Connection
DH+
PLC-5
KT, KL,
PCMK
DH+
DH+
RIO
Or
Or
GD1
RIO
GM1
SCANport GK1
RIO
DH+
PLC Comm
Adapter
RIO
DH+
Multi-Comm
Adapter
SCANport
1336T
(FORCE)
Important: In your communications
module, Switch 1 of SW3 must be On to
enable block transfer.
SCANport
1395
SCANport
Product
Important: For a list of SCANport products,
refer to Appendix A.
Important: RIO Block Transfer Pass Thru communications to drives take
approximately 2 seconds per point, and the PLC acting as the gateway must not
use any Block Transfer instructions addressed to the drive in its ladder logic
program.
Important: DriveMonitor32 and DriveBlockEditor32 cannot be used with RIO
Block Transfer Pass Thru communications systems.
Important: For RIO Block Transfer Pass Thru communications to work, the
PLC to which the drive is connected must be in RUN mode. If the PLC is not in
RUN mode, pass thru messages cannot be delivered to the connected drive
product.
Publication 9303-5.13 – March 1998
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
Checking Your
Hardware
Installation
Configuring
RSLinx for DH+ to
RIO Block Transfer
Pass Thru
Communications
5-3
Before configuring RSLinx and running DriveTools32, you should check:
•
All cable connections between the drive and PC are secure.
•
If you are using a 1203-GD1, 1203-GK1, or 1336-GM1 communications
module, Switch 1 of SW3 must be On to enable block transfer.
•
Power is applied to the drive.
To use RSLinx for a DH+ communications system, you need to:
1.
Configure the communication driver.
2.
Test the configured driver.
3.
Map the configured driver(s) to the KTPort Value.
Configuring the Communication Driver
To configure the communication driver, you need to:
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure Drivers. The
Configure Drivers dialog box appears.
Publication 9303-5.13 – March 1998
5-4
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
3.
Double-click 1784-KT/KTX(D)/PCMK/PKTX(D). The Configure
Allen-Bradley 1784-KTX/KTXD dialog box appears.
4.
In the Value field, select the correct DH+ device for your configuration.
5.
In the Property box, change any fields as required to match the settings
needed for your DH+ interface card.
6.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Close the Configure Drivers dialog box.
2.
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
3.
Publication 9303-5.13 – March 1998
Close the SuperWho window when you are finished.
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
5-5
Mapping the Configured Driver(s) to the KTPort Value
To map the configured driver(s) to the KTPort value, you need to:
1.
From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.
2.
Choose an unused KT:0 field to map the DH+ device to.
Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped the DH+ device. Enter the number in the
Enter mapping KT(X) Port # to use field in the Communication Setup dialog
box.
3.
Use the field’s drop box to map the configured driver to the port.
4.
Click OK or Apply.
Important: When using RIO Block Transfer Pass Thru for drive
communications from the PC, you cannot use Block Transfer messages in the
PLC program for this drive.
Publication 9303-5.13 – March 1998
5-6
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
Setting the
Communication
Information
To provide the DriveTools32 with information that it needs to establish a
connection between your PC and your drive, you need to:
1.
Start DriveManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select Data Highway Plus (DH+).
4.
In the Communications Type section, select DH+ to PLC RIO
Pass-Thru.
5.
In the Enter mapping KT(x) Port # to use field, enter the KT Port number.
Important: The KT(x) Port number must match the RSLinx KT:0 Port number
used for the DH+ device in the Configure Client Applications dialog box.
Publication 9303-5.13 – March 1998
6.
If applicable, select 1336T Two Word Header (used ONLY for 1336T
version 0.10).
7.
Click OK. A window displaying information about RIO Block Transfer
Pass Thru communications appears.
8.
Read the information and click OK.
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
Connecting to the
Drive
5-7
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The RIO Pass Through
Network Connect to Drive dialog box appears.
2.
In the Enter PLC (SLC) DH+ Station field, enter the DH+ station number.
The DH+ station number is the DH+ address of the PLC-5 that has the drive
connected to its RIO channel.
Valid station numbers are octal values between 0 and 77. If you are using a
1395 drive with a Multi-Comm board or a 1336 FORCE drive with a PLC
Communications Adapter Board, the station number is set on the
communications board.
Important: You can use the WHO button to determine the station number. The
WHO button is explained in further detail below.
3.
Select either PLC Type or SLC Type.
Important: If you are using SLC type, the SLC RIO scanner must be in slot 1.
4.
In the Enter Drive Rack # field, enter the RIO rack number associated with
this drive.
The rack number is specified in octal and is set in the communication
hardware module for the drive.
5.
In the Enter Starting Group # field, enter the RIO starting group number
associated with this drive.
The RIO starting group number is set in the communication hardware
module for the drive. Valid numbers are 0, 2, 4, and 6.
Publication 9303-5.13 – March 1998
5-8
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
6.
If applicable, select Use 1395 Protocol.
7.
Click OK.
After a short pause, either the DriveManager32 screen with the drive parameters
appears, or you are prompted to create a database.
Using the WHO
Button
The WHO button is located on the RIO Pass Through Network Connect to
Drive dialog box to help you determine the DH+ station number for the PLC to
which the drive is connected. When you click WHO, the WHO’s Active dialog
box scans the DH+ network and displays the devices that are currently active.
The following is an example of a WHO’s Active dialog box.
To select a device:
1.
Highlight the device.
2.
Click OK.
The station number of the device that you selected is used for the Enter
PLC(SLC) DH+ Station (0-77 Octal) field on the RIO Pass Through
Network Connect to Drive dialog box.
When you are using DH+ communications, the WHO’s Active dialog box
quickly completes the scan.
Publication 9303-5.13 – March 1998
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
5-9
The main window displayed in the WHO’s Active dialog box shows the
information read from the network WHO command. The information consists of
the following:
This field:
Specifies:
Station #
The network station number for each device on the network.
Device Type
The type of device that is associated with the network station number.
Station Name
The textual description contained in the device at the network station number.
The Bulletin 1395 drive does not support a network station name. Therefore, the
name shown on the network map is the same for all 1395 drives.
Comm. Device
The communication device type as it is identified on the network.
The WHO’s Active dialog box provides the following buttons:
•
SCAN
Click on the SCAN button to rescan the network to read station
information.
•
KT Port x
The KT Port radio buttons let you change the currently selected DH+
network KT card from within the WHO’s Active dialog box. When you
change the KT port definition, the dialog rescans the network based on the
new setting.
Publication 9303-5.13 – March 1998
5-10
Setting Up a DH+ to RIO Block Transfer Pass Thru Communications System
Notes:
Publication 9303-5.13 – March 1998
Chapter
6
Setting Up a ControlNet Direct Communications
System
Chapter Objectives
What is a
ControlNet
Communications
System?
This chapter provides information for configuring a ControlNet communications
system. After finishing this chapter, you will be able to perform the following
tasks:
•
Check your hardware installation.
•
Configure RSLinx for ControlNet direct communications.
•
Enter information into theDriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
ControlNet is a real-time, control-layer network providing high-speed
deterministic transport of both time-critical I/O data and messaging data. The
following is an example of this type of configuration:
Figure 6.1
ControlNet Communications System
PLC-5 (C)
ControlNet
Connection
KTC,
KTC(X)
ControlNet
ControlNet
Repeater
1786-RPA
Fiber
Module
1786-RPFM
CNet
ControlNet
Adapter
1336T
(FORCE)
Important: You cannot use DrivePanel32 to control a drive over a ControlNet
network.
Publication 9303-5.13 – March 1998
6-2
Checking Your
Hardware
Installation
Configuring
RSLinx for
ControlNet Direct
Communications
Setting Up a ControlNet Direct Communications System
Before setting up RSLinx and running DriveTools32, you should check your
hardware installation. You should:
•
Have a ControlNet interface device. For example, a 1784-KTC(X) board is
installed correctly in your PC.
•
Check to make sure all cable connections between the drive and PC are
secure.
•
Have a ControlNet Repeater Adapter and ControlNet Fiber Module
connecting the network to your drive.
To use RSLinx for a ControlNet direct communications system, you need to:
1.
Configure the communication driver.
2.
Test the configured driver.
3.
Map the configured driver(s) to the KTPort Value.
Configuring the Communication Driver
To configure the communication driver, you need to:
Publication 9303-5.13 – March 1998
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure Drivers. The
Configure Drivers dialog box appears.
Setting Up a ControlNet Direct Communications System
6-3
3.
Double-click 1784-KTC(X). The Configure Allen-Bradley 1784-KTC(X)
dialog box appears.
4.
Verify the information is correct.
5.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Close the Configure Drivers dialog box.
2.
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
3.
Close the SuperWho window when you are finished.
Publication 9303-5.13 – March 1998
6-4
Setting Up a ControlNet Direct Communications System
Mapping the Configured Driver(s) to the KTPort Value
To map the configured driver(s) to the KTPort value, you need to:
1.
From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.
2.
Choose an unused KT:0 field to map the ControlNet device to.
Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped the ControlNet device. Enter this number
in the Enter mapping KT(X) Port # to use field in the Communication Setup
dialog box.
Publication 9303-5.13 – March 1998
3.
Use the drop box for the field to map the configured driver to the port.
4.
Click OK or Apply.
Setting Up a ControlNet Direct Communications System
Setting the
Communication
Information
6-5
To provide the DriveTools32 with information that it needs to establish a
connection between your PC and your drive, you need to:
1.
Start DriveManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select ControlNet 1.5.
4.
In the Communications Type section, select ControlNet Direct.
5.
In the Enter mapping KTC(X) Port # to use field, enter the KT Port
number.
Important: The KTC(X) Port number must match the RSLinx KT:0 Port
number used for the ControlNet device in the Configure Client Applications
dialog box.
6.
If applicable, select 1336T Two Word Header (use ONLY for 1336T
version 0.10).
7.
Click OK.
Publication 9303-5.13 – March 1998
6-6
Connecting to the
Drive
Setting Up a ControlNet Direct Communications System
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The ControlNet Network
Connect to Drive dialog box appears.
2.
In the Enter ControlNet Station field, enter the ControlNet station number
for the 1336 FORCE drive.
Valid station numbers are decimal values between 0 and 99. The station
number is set on the PLC Communications Adapter board on the 1336
FORCE. For more information, consult the 1336-GT3EN user manual.
Important: You can use the WHO button to determine the station number. The
WHO button is covered in further detail below.
3.
Click OK.
After a short pause, either the DriveManager32 screen with the drive parameters
appears, or you are prompted to create a database.
Publication 9303-5.13 – March 1998
Setting Up a ControlNet Direct Communications System
Using the WHO
Button
6-7
The WHO button is located on the ControlNet Network Connect to Drive
dialog box to help you determine the station number for your drive. When you
click WHO, the WHO’s Active dialog box scans the network and displays the
devices that are currently active. The following is an example of a WHO’s
Active dialog box.
To select a device:
1.
Highlight the device.
2.
Click OK.
The station number of the device that you selected is used for the Enter
ControlNet Station (0-99 Dec.) field on the ControlNet Network Connect to
Drive dialog box
When you are using ControlNet communications, the WHO’s Active dialog
box quickly completes the scan.
The main window displayed in the WHO’s Active dialog box shows the
information read from the network WHO command. The information consists of
the following:
This field:
Specifies:
Station #
The network station number for each device on the network.
Device Type
The type of device that is associated with the network station number.
Station Name
The textual description contained in the device at the network station number.
The Bulletin 1395 drive does not support a network station name. Therefore, the
name shown on the network map is the same for all 1395 drives.
Comm. Device
The communication device type as it is identified on the network.
Publication 9303-5.13 – March 1998
6-8
Setting Up a ControlNet Direct Communications System
The WHO’s Active dialog box provides the following buttons:
•
SCAN
Click SCAN to rescan the network to read station information.
•
KT Port x
The KT Port radio buttons let you change the currently selected ControlNet
network KT card from within the WHO’s Active dialog box. When you
change the KT port definition, the dialog rescans the network based on the
new setting.
Publication 9303-5.13 – March 1998
Chapter
7
Setting Up an Allen-Bradley Ethernet to RIO Block
Transfer Pass Thru Communications System
Chapter Objectives
What is an
Ethernet
Communications
System?
This chapter provides information for configuring an Allen-Bradley Ethernet
communications system. After finishing this chapter, you will be able to perform
the following tasks:
•
Check your hardware installation.
•
Configure RSLinx for Ethernet to RIO Block Transfer Pass Thru
communications.
•
Enter information into the DriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
Ethernet is a local area network (LAN) that provides non-deterministic data
transport. The following is an example of this type of configuration.
Important: An Ethernet communications system cannot and should not be used
for controlling a device.
Publication 9303-5.13 – March 1998
7-2
Setting Up an Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications System
Figure 7.1
Allen-Bradley Ethernet Communications System
PLC-5 (E)
Ethernet Connection
Ethernet
TCP/IP
Ethernet
Ethernet
RIO
Or
Or
ENet RIO BT
Pass Thru
GD1
RIO
GM1
SCANport GK1
RIO
RIO
DH+
DH+
Multi-Comm
Adapter
PLC Comm
Adapter
SCANport
SCANport
1395
1336T
(FORCE)
SCANport
Product
Important: For a list of SCANport products,
refer to Appendix A.
Important: RIO Block Transfer Pass Thru communications to drives take
approximately 2 seconds per point, and the PLC acting as the gateway must not
use any Block Transfer instructions addressed to the drive in its ladder logic
program.
Important: DriveMonitor32 and DriveBlockEditor32 cannot be used with RIO
Block Transfer Pass Thru communications systems.
Important: For RIO Block Transfer Pass Thru communications to work, the
PLC to which the drive is connected must be in RUN mode. If the PLC is not in
RUN mode, pass thru messages cannot be delivered to the connected drive
product.
Checking Your
Hardware
Installation
Publication 9303-5.13 – March 1998
Before setting up RSLinx and running DriveTools32, you should check your
hardware installation. You should:
•
Have an Ethernet card running TCP/IP correctly installed.
•
Check that all cable connections between the computer and drive are secure.
Setting Up an Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications System
Configuring
RSLinx for
Ethernet to RIO
Block Transfer
Pass Thru
Communications
7-3
To use RSLinx for a serial communications system, you need to:
1.
Configure the communication driver.
2.
Test the configured driver.
Configuring the Communication Driver
To configure the communication driver, you need to:
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure Drivers. The
Configure Drivers dialog box appears.
Publication 9303-5.13 – March 1998
7-4
Setting Up an Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications System
3.
Double-click Ethernet to PLC5 or 5820-El. The Configure Ethernet-toAB Communications dialog box appears.
4.
In the Driver Station field, enter a unique station number for your PC on
the Ethernet. Valid numbers are from 0 to 63.
5.
In the IP Address or hostname field, enter the IP address.
Remember the IP address. You will enter it again in the Communications
Setup dialog box.
6.
In Current Mappings, select an available Mapping.
7.
Click Accept.
8.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Publication 9303-5.13 – March 1998
Close the Configure Drivers dialog box.
Setting Up an Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications System
2.
7-5
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
3.
Setting the
Communication
Information
Close the SuperWho window when you are finished.
You need to provide DriveTools32 with some information that it needs to
establish a connection between your PC and your drive. To do this, you need to:
1.
Start DriverManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, click A-B Ethernet.
4.
In the Communications Type section, click Ethernet RIO Block
Transfer Pass Thru.
5.
In the Enter IP Address field, enter the same IP address entered in the
Ethernet-to-AB Communications dialog box.
Publication 9303-5.13 – March 1998
7-6
Setting Up an Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications System
Connecting to the
Drive
6.
If applicable, select 1336T Two Word Header (Use ONLY for 1336T
version 0.10).
7.
Click OK. A window displaying information about RIO Block Transfer
Pass Thru communications appears.
8.
Read it and click OK.
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The Ethernet Connect to
Drive dialog box appears.
2.
In the Enter Drive Rack # field, enter the RIO rack number associated with
this drive.
The rack number is specified in octal and is set in the communication
adapter for the drive.
3.
In the Enter Starting Group # field, enter the RIO starting group number
associated with this drive.
The RIO starting group number is set in the communication adapter for the
drive. Valid starting group numbers are 0, 2, 4, and 6.
4.
If necessary, click Use 1395 Protocol.
5.
Click OK.
After a short pause, either the DriveManager32 screen with the drive parameters
appears, or you are prompted to create a database.
Publication 9303-5.13 – March 1998
Chapter
8
Using RSLinx Gateways
Chapter Objectives
This chapter provides information for configuring and using RSLinx gateways
from a client computer. After finishing this chapter, you will be able to perform
the following tasks:
•
Check your hardware installation.
•
Configure RSLinx for RSLinx Gateway Communications.
•
Enter information into the DriveTools32 application’s Communication
Setup dialog box.
•
Begin communicating with your drive.
Important: Your server must already be set up.
What is a
Gateway?
A gateway provides messaging through a server connected to a PLC-5. The
PLC-5 then acts as a gateway to drives on DH+, or the RIO network. The
following is an example of this type of configuration:
Figure 8.1
RSLinx Gateway to DH+ and to DH+ RIO Block Transfer Pass Thru Connection
PLC-5
Gateway
Connection
Server
Client
RSLinx
TCP/IP
Ethernet
TCP/IP
DH+
Ethernet
DH+
RIO
Or RIO BT
Pass Thru
Or
GD1
RIO
GM1
SCANport GK1
RIO
DH+
PLC Comm
Adapter
RIO
DH+
Multi-Comm
Adapter
SCANport
SCANport
1336T
(FORCE)
1395
SCANport
Product
Important: For a list of SCANport products,
refer to Appendix A.
Publication 9303-5.13 – March 1998
8-2
Checking Your
Hardware
Installation
Using RSLinx Gateways
Before setting up RSLinx and running DriveTools32, you should check your
hardware installation. You should:
•
Have an Ethernet card running TCP/IP correctly installed in your PC.
•
Check that you are logged on to your local area network.
To start DriveTools32 applications, click Start, Programs, DriveTools32 and
then the DriveTools32 application (e.g., DriveManager32).
Configuring
RSLinx for RSLinx
Gateways
To use RSLinx for an RSLinx Gateway communications system, you need to:
1.
Configure the communication driver.
2.
Test the configured driver.
3.
Map the configured driver(s) to the KTPort Value.
Configuring the Communication Driver
To configure the communication driver, you need to:
Publication 9303-5.13 – March 1998
1.
Start the RSLinx application.
2.
From the Communications menu, select Configure drivers. The
Configure Drivers dialog box appears.
Using RSLinx Gateways
8-3
3.
Double-click Remote Devices via Linx Gateway. The Remote Devices
via Linx Gateway dialog box appears.
4.
From the Server Name list, select the server to which you want to connect.
A list of Remote drive names appears.
5.
From the Remote driver name list, select the DH+ driver to which you
want to connect.
6.
Click OK.
Testing the Configured Driver
To test the configured driver, you need to:
1.
Close the Configure Drivers dialog box.
2.
From the Communications menu, select SuperWho.
If you have only one configured driver, the communication between the
node(s) on the network should be displayed.
If you have more than one configured driver, double-click on the driver you
just configured to view the communication between the node(s) on the
network.
Publication 9303-5.13 – March 1998
8-4
Using RSLinx Gateways
3.
Close the SuperWho window when you are finished.
Mapping the Configured Driver(s) to the KTPort Value
To map the configured driver(s) to the KTPort value, you need to:
1.
From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.
2.
Choose an unused KT:0 field to which to map your TCP driver.
Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped the TCP device. Enter the number in the
Enter mapping TCP...Port # to use field in the Communication Setup dialog
box.
Publication 9303-5.13 – March 1998
3.
Use the drop box for the field to map the configured driver to the port.
4.
Click OK or Apply.
Using RSLinx Gateways
Setting the
Communication
Information
8-5
To provide DriveTools32 with information that it needs to establish a connection
between your PC and your drive, you need to:
1.
Start DriveManager32.
2.
From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.
3.
In the Communications section, select Remote devices (Gateway).
4.
In the Communications Type section, select the appropriate
communications type.
5.
In the Enter mapping TCP Port # to use field, enter the KT Port number.
Important: The Port number must match the RSLinx KT:0 Port number used for
the TCP device in the Configure Client Applications dialog box.
6.
If applicable, select 1336T Two Word Header (used ONLY for 1336T
version 0.10).
7.
Click OK. A window displaying information on RIO Pass Thru
communications may appear.
8.
Click OK.
Publication 9303-5.13 – March 1998
8-6
Connecting to the
Drive
Using RSLinx Gateways
To connect to the drive, you need to:
1.
From the Drive menu, select Connect to Drive. The Gateway DH+
Network Connect to Drive dialog box appears.
2.
In the Enter DH+ Station field, enter the station number.
Valid station numbers are octal values between 0 and 77. If you are using a
1395 drive with a Multi-Comm board or a 1336 FORCE drive with a PLC
Communications Adapter Board, the station number is set on the
communications board.
Important: You can use the WHO button to determine the station number. The
WHO button is covered in further detail below.
3.
Click OK.
After a short pause, either the DriveManager32 screen with the drive parameters
appears, or you are prompted to create a database.
Publication 9303-5.13 – March 1998
Using RSLinx Gateways
Using the WHO
Button
8-7
The WHO button is located on the Gateway DH+ Network Connect to Drive
dialog box to help you determine the station number for your drive. When you
click WHO, the WHO’s Active dialog box scans the SCANport list and
displays the devices that are currently active. The following is an example of a
WHO’s Active dialog box.
To select a device:
1.
Highlight the device.
2.
Click OK.
The station number of the device that you selected is used for the Enter DH+
Station (0-77 Octal) field on the Gateway DH+ Connect to Drive dialog box.
The main window displayed in the WHO’s Active dialog box shows the
information read from the network WHO command. The information consists of
the following:
This field:
Specifies:
Station #
The network station number for each device on the network.
Device Type
The type of device that is associated with the network station number.
Station Name
The textual description contained in the device at the network station number.
The Bulletin 1395 drive does not support a network station name. Therefore, the
name shown on the network map is the same for all 1395 drives.
Comm. Device
The communication device type as it is identified on the network.
Publication 9303-5.13 – March 1998
8-8
Using RSLinx Gateways
The WHO’s Active dialog box provides the following buttons:
•
SCAN
Click on the SCAN button to rescan the network to read station
information.
•
KT Port x
The KT Port radio buttons let you change the currently selected DH+
network KT card from within the WHO’s Active dialog box. When you
change the KT port definition, the dialog rescans the network based on the
new setting.
Publication 9303-5.13 – March 1998
Appendix
A
SCANport-Compatible Products Supported by
DriveTools32
Appendix
Objectives
This appendix lists the bulletin numbers of SCANport-compatible products in
DriveTools32, their product names, and their sub-directories.
Supported
SCANportCompatible
Database Files
The following table lists the most common SCANport products.
Bulletin Number
Product
Sub-Directory
1305 AC Micro Drive
1305 AC Micro Drive
D_1305N
1336E IMPACT Drive
1336 IMPACT Drive
D_1336E
1336S Plus AC Drive
1336 Plus AC Drive (Fractional)
D_1336F
1336S Plus AC Drive
1336 Plus AC Drive
D_1336HP
1336T w/ PLC Communications
1336 FORCE
D_1336TP
1336T w/ STD Adapter
1336 FORCE
D_1336TS
1336T w/ CNet Adapter
1336 FORCE
D_1336TC
1394 Servo AC Drive
1394 Servo AC Drive
D_1394
1397 DC Drive
1397 DC Drive
D_1397
1557 Medium Voltage AC Drive
1557 Medium Voltage AC Drive
D_1557
2364F RGU DC Bus Regen Front End
2364F RGU DC Bus Regen Front End
D_2364F
1336F Plus II
1336 Plus II
D_07
1336R Line Regeneration Package
1336 Line Regeneration Package
D_19
150 SMC
SMC Dialog Plus
D_150
193 SMP
SMP-3
D_193
Important: DriveTools32 supports more SCANport-compatible products than
are listed in the above table. Refer to page A-2 for more information.
Publication 9303-5.13 - March 1998
A-2
DriveTools32 and
Database Files
SCANport-Compatible Products Supported by DriveTools32
DriveTools32 uses a unique database file for each drive product so that you can
configure each drive individually. DriveTools32 ships with many of the database
files it will need (refer to the table above).
If you connect to a drive for which DriveTools32 does not have a database file,
you will be prompted to upload a new database file.
Click Yes and DriveTools32 uploads a database which you can then configure.
When the upload is complete, DriveTools32 prompts you.
Click OK.
Publication 9303-5.13 – March 1998
Data Highway Plus, DH+, DriveBlockEditor32, DriveManager32, DriveMonitor32, DrivePanel32, DriveTools32,
DriveTrending32, 1336 FORCE, 1336 IMPACT, ControlNet, RSLinx, and SCANport are trademarks of Rockwell
International, Inc.
PLC and PLC-5 are registered trademarks of Rockwell International, Inc.
Windows, WindowsNT, and Microsoft are either registered trademarks or trademarks of Microsoft Corporation.
Publication 9303-5.13 – March 1998
185856
Copyright 1998 Allen-Bradley Company, Inc.
Printed in USA