Nextel comm Modem IR1200 Administrator's Guide


Add to my manuals
122 Pages

advertisement

Nextel comm Modem IR1200 Administrator's Guide | Manualzz

iR1200 Rugged Modem iR1200 GPS-Enabled Modem

Administrator’s Guide

General

Table of Contents

Table of Contents

Table of Figures................................................................................................1

FCC Compliance ..............................................................................................3

Required Components .....................................................................................5

How to Order..................................................................................................5

Online Documentation ...................................................................................6

Introduction......................................................................................................7

Welcome to Nextel ......................................................................................7

Using This Guide........................................................................................7

Nextel Coverage.......................................................................................7

Nextel Customer Care..............................................................................8

Overview ...........................................................................................................9

General Overview ..........................................................................................9

Modem Operating Modes.............................................................................10

Modem Configurations.................................................................................10

iR1200 Rugged Modem ............................................................................10

iR1200 GPS-Enabled Modem...................................................................11

Modem Specifications..................................................................................12

Getting Started ...............................................................................................15

Connecting the Modem ................................................................................15

Communication Indicators ...........................................................................17

Packet Data..............................................................................................19

iR1200 Modem

Circuit Switched Data ..............................................................................19

Installing iDEN Packet Data Applet..........................................................21

Hardware and Installation Requirements......................................................21

Before You Begin.........................................................................................22

Download Software Instructions ..................................................................22

Windows 95/98/ME ..................................................................................23

Windows NT .............................................................................................

26

Windows 2000 ..........................................................................................31

Setting Up Windows Components.................................................................35

Verify Dial-Up Networking .........................................................................35

Windows 95/98/ME ..................................................................................35

Windows NT .............................................................................................36

Windows 2000 ..........................................................................................36

Verify TCP/IP Protocol Installation .............................................................36

Windows 95/98/ME ..................................................................................37

Windows NT/2000 ....................................................................................38

Installing the Dial-Up Adapter .....................................................................39

Windows 95/98/ME ..................................................................................39

Windows NT/2000 ....................................................................................39

Manual Modem Configuration .....................................................................41

Modem Configuration – Windows 95/98/ME ..............................................41

Install the Modem.....................................................................................41

Configure the Modem Driver ...................................................................42

Create a Dial-up Networking Connection................................................43

25

Table of Contents

Modem Configuration – Windows NT.........................................................44

Install the Modem.....................................................................................44

Configure the Modem Driver ...................................................................46

Create a Dial-up Networking Connection................................................47

Modem Configuration – Windows 2000 ......................................................48

Install the Modem.....................................................................................48

Create and Configure a Dial-up Networking Connection ........................49

Modify Dial-up Connection Parameters...................................................51

Modem Profiles and Settings.........................................................................53

HyperTerminal Setup ...................................................................................54

Opening a HyperTerminal Session...............................................................56

Configuring With AT Commands ................................................................57

Modem Initialization ................................................................................57

Restore Factory Defaults..........................................................................57

Activate DTR Monitoring .........................................................................58

Activate DCD Management......................................................................58

Set Computer’s IP Address.......................................................................58

Select iDEN Packet Wireless Data.........................................................59

Select SLIP or PPP...................................................................................59

Mobile IP Activation ................................................................................60

Mobile IP Home Agent Address ...............................................................60

Mobile IP Authentication Key ..................................................................60

Mobile IP Security Parameter Index (SPI)...............................................61

Mobile Node IP Prefix Length..................................................................61

Header Compression................................................................................62

iR1200 Modem

Saving AT Settings....................................................................................62

GPS Default Parameters...............................................................................63

AT Commands................................................................................................65

General AT Commands................................................................................65

User Image Profile Commands.....................................................................66

Registration, Reset, and Authentication Commands ....................................66

Network Status Commands ..........................................................................66

Other Useful AT Commands........................................................................67

Answer......................................................................................................67

Command Mode Echo ..............................................................................67

Dial...........................................................................................................68

Hang-up....................................................................................................69

Request Modem Information ....................................................................69

Go Online.................................................................................................69

Pulse Dialing............................................................................................70

Quiet Mode...............................................................................................70

Tone Dialing.............................................................................................70

Verbose Result Codes...............................................................................71

Extended Result Codes .............................................................................71

Restore User Defaults ..............................................................................72

DCD Behavior..........................................................................................72

DTR Behavior...........................................................................................73

Restore Factory Default ...........................................................................73

Local Flow Control (Traditional).............................................................74

Display Current Parameter Value............................................................74

Local Character Framing.........................................................................75

Table of Contents

Local Flow Control (PCCA).....................................................................75

Local Data Rate .......................................................................................76

Lock/Unlock the DCE...............................................................................77

Change the DCE’s PIN. ...........................................................................77

Packet Data Sleep Timer..........................................................................78

SLIP MTU ................................................................................................78

Select Mobile IP Client.............................................................................79

Mobile IP Authentication Key ..................................................................79

Mobile IP Session Timer ..........................................................................80

DTE IP Address........................................................................................80

DTE IP Address Prefix Length .................................................................81

Data Encryption .......................................................................................81

DTE Stack.................................................................................................82

WDS Stack................................................................................................83

Service Class ............................................................................................83

Packet Data Registration Timeout............................................................83

Circuit Data Auto-Answer........................................................................84

Circuit Data Establishment Timeout ........................................................84

Comma Dial Modifier Timer ....................................................................85

Circuit Data Idle Timer............................................................................85

S-Registers ......................................................................................................87

S-Registers ...................................................................................................87

Programming the S-Register ........................................................................87

Reading an S-Register Value........................................................................88

Supported S-Registers ..................................................................................88

iR1200 Modem

Troubleshooting..............................................................................................91

Common Problems .......................................................................................91

Error Messages.............................................................................................93

Diagnostic Commands .................................................................................94

Extended Error AT Command ..................................................................95

Extended Error Result Codes ...................................................................95

Safety Notice ...................................................................................................99

Safe and Efficient Operation Guidelines ......................................................99

Exposure to Radio Frequency Energy ..........................................................99

Medical and Personal Electronic Devices ....................................................99

Pacemakers ..............................................................................................99

Hearing Aids ..........................................................................................100

Other Medical Devices ...........................................................................100

Interference with Other Electronic Devices................................................100

Copyright and Trademark ..........................................................................101

Appendix A: Glossary..................................................................................103

Index..............................................................................................................111

Table of Contents

IMPORTANT!

Please Read Safety Notice on Page 99 before using the iR1200 Modem.

Last Updated

RFM-4002-5015 Rev 3

November 2003

Table of Figures

Table of Figures

Table of Figures

Figure 1 – iR1200 GPS-Enabled Modem

Figure 2 – Rear Panel of iR1200 Rugged Modem

Figure 3 – Rear Panel of iR1200 GPS-Enabled Modem

Figure 4 – Front Panel View of iR1200 Modem

Figure 5 – Cabling Diagram (Fixed Environment)

Page

9

11

11

15

16

RFM-4002-5015 Rev 3 1

iR1200 Modem

2 nextel.com

FCC Compliance

FCC Compliance

DECLARATION OF CONFORMITY

Per FCC CFR 47 2.989

Responsible party name:

Address:

Phone number: eLutions, Inc.

5905 Breckenridge Parkway

Suite F

Tampa, FL 33610

1-800-836-9909

Hereby declares that the product:

Product name:

Model Number: iR1200 GPS-Enabled Modem

4000-C5-RFM

Product name:

Model Number: iR1200 Rugged Modem

4100-C5-RFM

Conforms to the following regulation:

FCC Part 15, subpart B

FCC Part 90, subpart S

Class B Digital device

Date: May 16, 2003

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and 90 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference or by one or more of the following measures:

-- Reorient or relocate the receiving antenna.

-- Increase the separation between the equipment and receiver.

-- Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected.

-- Consult the dealer or an experienced radio/TV technician for help.

RFM-4002-5015 Rev 3 3

iR1200 Modem

4 nextel.com

Required Components

Required Components

The following table lists components that have been approved for use with the iR1200 Rugged Modem and iR1200 GPS-Enabled modems.

Part No.

5000-C5-RFM

Description

Magnetic Mount Cellular Antenna

5010-C5-RFM Magnetic Mount Cellular Antenna (spring wire)

5020-C5-RFM

5030-C5-RFM

5040-C5-RFM

5050-C5-RFM

Direct Mount Cellular Antenna

Magnetic Mount GPS Antenna

Fixed Mount Cellular Antenna (spring wire)

Dual Fixed Mount Cellular/GPS Antenna

5060-C5-RFM

5100-C5-RFM

5200-C5-RFM

Dual Covert Mount Cellular/GPS Antenna

Vehicle Power Harness

AC Power Adapter (standard temperature)

How to Order

To obtain any of the items listed above, please contact your Nextel sales representative or visit www.elutions.com/wireless.

RFM-4002-5015 Rev 3 5

iR1200 Modem

Online Documentation

The iR1200 modem is shipped with the following product documentation.

Additional copies of these documents can be downloaded (at no charge) online at www.elutions.com/wireless or calling 1-888-349-4338.

Part No.

RFM-4000-5015

RFM-4001-5015

RFM-4003-5015

Description

Installation Guide

Quick Reference Guide

Warranty Card/Installation and Usage

Requirements

6 nextel.com

Introduction

Introduction

Welcome to Nextel

Thank you for purchasing the Nextel iR1200 modem. This modem works on the iDEN network. Once installed and configured, the iR1200 modem provides users with wireless data communications.

This chapter includes:

Using This Guide

Nextel Coverage

Nextel Customer Care Information

Page 7

Page 7

Page 8

Using This Guide

This guide provides instructions for installing the iR1200 Rugged Modem and the iR1200 GPS-Enabled Modem.

Nextel Coverage

For details on Nextel digital cellular and data coverage, visit nextel.com.

NOTE: Transmission and reception speed may vary, based on your relative position within the coverage area. If you are in a marginal location (close to the border of the coverage area), the throughput of your modem during data transmission may be affected.

RFM-4002-5015 Rev 3 7

iR1200 Modem

Nextel Customer Care

For customer care issues including technical support contact Nextel Customer

Care at 1-800-639-6111.

When you call, please have a detailed description of your problem. To provide you with fast and quality support, our Customer Care representative may ask for information on the following:

• Computer operating system (Windows 95/98/NT/2000/CE)

• Version of the operating system (e.g. NT 4, Windows 95 Version B, CE

2.1, etc.)

• Information regarding the modem (most can found on the diagnostic menu)

• Geographic location of use

• Extended Error Result Codes

8 nextel.com

Overview

Overview

This chapter provides general details about the iR1200 modem.

This chapter includes:

General Overview

Modem Operating Modes

Modem Configurations

Modem Specifications

Page 9

Page 10

Page 10

Page 12

General Overview

The iR1200 Modem is an iDEN data modem consisting of a modem card and an optional GPS (iR12000 GPS-Enabled Modem) receiver, contained in a rugged enclosure, to provide wireless data communications.

The iR1200 modem is easy to mount, whether in a mobile or a fixed environment.

Figure 1. iR1200 GPS-Enabled Modem

RFM-4002-5015 Rev 3 9

iR1200 Modem

Modem Operating Modes

The iR1200 provides the following data connection modes:

Packet Data: A wireless modem connection used for accessing the

Internet, sending and receiving e-mail, and transferring small files over the packet data network using standard IP protocols.

Data is sent in packets (blocks) at high speed.

Circuit Switched Data: A wireless modem connection for sending and receiving data (faxes, files, etc.) over the circuit-switched cellular channel, providing a direct point-to-point connection with the destination device.

Modem Configurations

Nextel offers two models of the iR1200 Modem. While both are designed to provide wireless communication for rugged environments, one model offers

GPS capability as well.

The iR1200 modem can be purchased with the following configurations:

iR1200 Rugged Modem (Base Model) - Available in bulk or individual packaging

iR1200 GPS-Enabled Modem - Available in bulk or individual packaging iR1200 Rugged Modem

The following diagram displays the components on the rear panel of the iR1200

Rugged Modem.

10 nextel.com

Overview

Ignition Sense /

Bypass

Connector

Modem

Serial Data

Connector

12VDC Power

Connector

Modem Antenna

Connector

Figure 2. Rear Panel of iR1200 Rugged Modem iR1200 GPS-Enabled Modem

The following diagram displays components on the rear panel of the iR1200

GPS-Enabled Modem.

GPS Serial

Data

Connector

GPS Antenna

Connector

Ignition Sense /

Bypass

Connector

Modem

Serial Data

Connector

Modem Antenna

Connector

12VDC Power

Connector

Figure 3. Rear Panel of iR1200 GPS-Enabled Modem

RFM-4002-5015 Rev 3 11

iR1200 Modem

Modem Specifications

Rugged metal enclosure

Status monitoring

LED

External Modem

Software

Internal Modem

Software

Extruded Aluminum

One bi-color LED for operating status

User to utilize Windows drivers

Micro controller firmware

Radio Frequency Tx 806-821 MHz Rx 851-866 MHz

TX Output Power 0.6 W at 25 degrees C

Static Sensitivity -111dbm @ -10% BER

Input Voltage

Current

Consumption

Dimensions

12VDC nominal, 10 to 16 VDC operating range

0.1 Amps average, 1.5 Amps peak

Approximately 5.04"W x 2.21"H x 7"D

Weight Approximately 625 grams

Data Connector DB-9 for modem, DB-9 for GPS (optional)

Power Connector Molex 39-01-2020 with 39-00-0186 pins

Ignition Connector Molex 39-01-2040 with 39-00-0186 pins

Operating

Temperature

-25 degrees C to +60 degrees C

Storage Temperature -40 degrees C to +85 degrees C

Humidity 0-95% non-condensing

12 nextel.com

Overview

Vibration

Shock per TIA/EIA 603 par 3.3.4 per MIL-STD-810E, method 516.4, procedure I

Dust/Water

Resistance

External LED

Lights/Indicators

Dust per MIL-STD-810E, method 510.3, procedure I

Water per MIL-STD-810E, method 506.3, procedure

II

External Reset

Button (RF & Master reset)

Yes

6 Single color LEDs for modem RS-232 signal status

(TX, RX DR, DSR, CTS, RTS per RS-232-C/E

Specifications)

GPS Receiver 8 channel, NMEA 0183 protocol

External Antenna

Connectors

Mini UHF female for modem and MCX female for

GPS

Yes, Ignition sense, 6'-20' range

Power Requirements

Yes, 5 sec power-off delay from loss of ignition (12V still available)

Internal monitoring with self-reset capability

Yes, field support diagnostic screen provided and self-reset

RFM-4002-5015 Rev 3 13

iR1200 Modem

14 nextel.com

Getting Started

Getting Started

This chapter describes how to connect your modem to a computer or mobile device in preparation for the configuration process.

This chapter includes:

Connecting the Modem

Communication Indicators

Page 15

Page 17

Connecting the Modem

The following table describes how to connect the modem to the computer using the RS-232 cable.

LED (signal indicators) displays the modem’s serial interface status.

Diagnostic Connector used to receive modem diagnostic information.

Status LED displays the modem’s iDEN network status.

Reset Button used to power cycle the modem and reestablishes connection to the network.

Figure 4 – Front Panel View of the iR1200 Modem

RFM-4002-5015 Rev 3 15

iR1200 Modem

COMPUTER

120VAC

POWER

SUPPLY

GPS ANTENNA

(OPTIONAL)

MODEM

ANTENNA

POWER

IGNITION iR1200

IGNITION

BYPASS

PLUG

Figure 5 – Cabling Diagram (Fixed Environment)

RS-232

GPS DATA

RS-232

MODEM DATA

NOTE: DCE (data communication equipment) refers to your iR1200

Modem

DTE (data terminal equipment) refers to your computer or mobile device.

1 Make sure that there is no power being supplied to the modem

(unplug the ignition bypass plug or power connector – refer to

Figure 5 – Cabling Diagram above).

2 Connect the DB-9-P (male) connector on the cable to the DB-

9-S (female) to the connector DCE (labeled Diagnostic on the modem’s front panel –refer to Figure 4 on page 15).

3 Connect the DB-9-P connector on the cable to the DB-9-S connector on the DTE.

4 Connect the modem antenna cable to the connector labeled

MODEM antenna on the rear panel of the modem (refer to

Figures 2 and 3 on page 11).

16 nextel.com

Getting Started

5 Plug the AC power cord into the 2-prong polarized power jack located on the rear panel of the modem. Plug the other end into a 120VAC-wall outlet.

6 Insert the ignition bypass plug into the 4-prong polarized

IGNITION jack located on the rear panel of the modem (refer to Figures 2 and 3 on page 11).

7 The STATUS Led light will be solid RED. This indicates that the modem is attempting to register with the iDEN network.

8 A blinking green light indicates that the modem has successfully registered with the iDEN network.

Communication Indicators

Your iR1200 modem is equipped with the LED indicators (located on the front panel of the modem – see Figure 4) that identify various communication functions.

The following table contains descriptions of the LED indicators and their functions.

Signal

Tx

Rx

RTS

Color

Blinking

Green

Blinking

Green

Green

(Off)

Indication

Modem is transmitting data to the computer data terminal (DTE).

Modem is receiving data from the computer. Modem is receiving data from the DTE.

Request To Send from computer (DTE) is asserted (not asserted).

RFM-4002-5015 Rev 3 17

iR1200 Modem

Signal

CTS

DTR

Color

Green

(Off)

Green

(Off)

Indication

Clear To Send from modem is asserted

(not asserted).

Data terminal equipment is ready (not ready).

DSR Green

(Off)

Modem is ready (not ready).

STATUS Solid Red The modem is searching for a signal within the Nextel network. If the modem status changes from blinking green back to solid red, the signal has been lost and the modem is attempting to re-acquire.

NOTE: If after several minutes the status does not return to green, you may be out of range. The modem will attempt to re-acquire automatically when you are back in range.

NOTE: The STATUS indicators are different depending on the mode in which the modem is operating.

18 nextel.com

Getting Started

The following tables describe the STATUS indicators for the Packet Data and

Circuit Switched Data operating modes.

Packet Data

STATUS

STATUS

Blinking

Green

Blinking

Green

In-range (modem is connected to the

Nextel network) but idle (but not passing data).

The modem is in use – Nextel network communication is active and is passing data.

Circuit Switched Data

STATUS

STATUS

Blinking

Green

Solid

Green

In-range (modem is connected to the

Nextel network) but idle (but not passing data).

The modem is in use – Nextel network communication is active and is passing data.

RFM-4002-5015 Rev 3 19

iR1200 Modem

20 nextel.com

Installing iDEN Packet Data Applet

Installing iDEN Packet Data Applet

In this chapter, you will learn how to install the iDEN Packet Data Applet.

The applet enables connectivity for the iR1200 modem connected to a laptop or mobile device and allows you to monitor the service and modem status such as signal strength.

This chapter includes:

Hardware and Installation Requirements

Before You Begin

Download and Installation Instructions

Instructions for Windows 95/98/ME

Instructions for Windows NT

Instructions for Windows 2000

Page 21

Page 22

Page 22

Page 23

Page 26

Page 31

Hardware and Installation Requirements

To run the installation program, you will need the following:

• An IBM compatible PC with:

586 (or higher) processor

Microsoft Windows 95, 98, NT or 2000, XP

Minimum 8 MB of addressable RAM

3 MB free hard-disk space

Recommended: Mouse or compatible pointing device

• Communication software

• Standard Internet browser (such as Internet Explorer or Netscape)

• An active account with Nextel (for connection to the iDEN network)

RFM-4002-5015 Rev 3 21

iR1200 Modem

NOTE: Please check the Nextel.com website for the latest hardware and installation requirements.

Before You Begin

Windows must have a Dial-up Networking Version 1.3 or later and the TCP/IP protocol Installed.

NOTE: If the version of your Dial-up Networking is earlier than v1.3, please go to www.microsoft.com to obtain an upgrade.

!

Before proceeding, please check that your computer has a network card or security program that prevents

IP address changes.

• Windows Dial-Up Networking version 1.3 or higher installed

(refer to the “Manual Modem Configuration” chapter in this guide for installation instructions)

• TCP/IP installed (refer to the “Setup Windows Components” chapter in this guide for installation instructions)

• Dial-Up Adapter installed (refer to the “Setup Windows

Components” chapter in this guide for installation instructions)

Download Software Instructions

This software configures your computer to receive Packet Data services. It also monitors the service and provides service status information such as battery status and signal strength.

NOTE: Windows NT and 2000 users will need administrator rights to complete the installation.

22 nextel.com

Installing iDEN Packet Data Applet

The following table describes steps to download and install the iDEN data packet applet.

Windows 95/98/ME

1 Access the Nextel website by entering www.nextel.com.

From the Nextel Home Page, select Services Nextel

Online. The Nextel Online Services page appears.

2 From the Nextel Online page, find and select Wireless

Web Access PacketstreamGold.

3 The Packetstream Gold Service page appears.

4 Click the Download Packetstream Gold Software (PC

Only) link. The Download Packetstream Gold Software page appears.

5 Scroll down the page to find and select either Nextel

Online Packetstream Gold Service Install link or the

Download Now link located that the bottom of the page.

6 The download program will copy the files that are needed to install the software to the appropriate location on your

RFM-4002-5015 Rev 3 23

iR1200 Modem computer.

IMPORTANT: When you have finished downloading the program, you MUST connect the data cable to your modem and computer before proceeding further.

7 Find the program in the appropriate folder and double-click the Setup.exe to launch the program to initiate the installation process.

NOTE: The setup.exe will be contained in a zip or compressed file.

8 Click Next to accept the default Program Folder, iDEN

Data Modem Applet. The installation program starts, a status window opens while the files are copying.

9 The Installshield Wizard screen appears during the setup process.

10 Click Next on the iDEN Packet Data Applet Setup screen.

11 The iDEN License Agreement screen appears. Select Yes to accept the terms of the agreement and proceed with the installation.

12 The Customer Information window opens. Enter your name and company then click Next.

13 The Choose Destination Location window opens. Click

Next to accept the default destination folder, C:\Program

Files.

14 The Select Program Folder window opens. Click Next to accept the default program folder , iDEN Packet Data

Applet.

15 After the files are copied, the Question window opens.

Click Yes to add a shortcut to your taskbar then click OK to continue.

24 nextel.com

Installing iDEN Packet Data Applet

16 Click OK to the message stating that you “must maximize the ‘Communication Settings’ window…”.

17 Click Communication Settings on your taskbar to maximize the window. The Communication Settings window opens.

NOTE: Check to make sure that your modem is turned on and connected to your computer before continuing with the installation.

18 Select the following value on the Communication Settings window:

• Click the Auto Detect to have the software automatically check for the COM Port or select the appropriate COM Port

(typically COM1)

Multiple Baudrate should be unchecked

Baud Rate: 19200 (bps)

The program will check the communication settings and attempt

RFM-4002-5015 Rev 3 25

iR1200 Modem to connect to the modem.

19 The Packet Data Configuration window opens. Select No,

I would like to configure my modem later or my modem

has already been configured then click Next.

20 The Installation Complete window opens. Select Finish on the following screens to complete the installation process.

21 The Setup Complete window opens. Click Finish.

Windows NT

NOTE: Administrative rights are required to install the software on

Windows NT. Contact your IT Representative or Systems

Administrator for assistance.

1 Access the Nextel website by entering www.nextel.com.

From the Nextel Home Page, select Services Nextel

Online. The Nextel Online Services page appears.

26 nextel.com

Installing iDEN Packet Data Applet

2 From the Nextel Online page, find and select Wireless

Web Access PacketstreamGold.

3 The Packetstream Gold Service page appears.

4 Click the Download Packetstream Gold Software (PC

Only) link. The Download Packetstream Gold Software page appears.

5 Scroll down the page to find and select either Nextel

Online Packetstream Gold Service Install link or the

Download Now link located that the bottom of the page.

6 The download program will copy the files that are needed to install the software to the appropriate location on your computer.

IMPORTANT: When you have finished downloading the program, you MUST connect the data cable to your modem and computer before proceeding further.

7 Find the program in the appropriate folder and double-click the Setup.exe to launch the program to initiate the installation process.

NOTE: The setup.exe will be contained in a zip or compressed file.

8 Click Next to accept the default Program Folder, iDEN

Data Modem Applet. The installation program starts, a status window opens while the files are copying.

9 The Installshield Wizard screen appears during the setup process.

10 Click Next on the iDEN Packet Data Applet Setup screen.

11 The iDEN License Agreement screen appears. Select Yes to accept the terms of the agreement and proceed with the installation.

12 The Customer Information window opens. Enter your name and company then click Next.

RFM-4002-5015 Rev 3 27

iR1200 Modem

13 The Choose Destination Location window opens. Click

Next to accept the default destination folder, C:\Program

Files.

14 The Select Program Folder window opens. Click Next to accept the default program folder , iDEN Packet Data

Applet.

15 After the files are copied, the Question window opens.

Click Yes to add a shortcut to your taskbar then click OK to continue.

16 An additional Information window opens. Click OK to continue with the installation.

17 The Add/Remove Hardware window opens. Click the

Don’t Detect my modem; I will select it from a list of checkbox then click Next.

18 The Modem Selection window opens. From

Manufacturers list box, locate and select Motorola and

Motorola iDEN plus Series then click Next.

19 The Port Selection window opens. Highlight the COM port that your modem is connected and click Next.

20 The Modem Installation Finish window opens. Click

Finish.

21 The Information window opens indicating that you need to add the modem to the RAS manager and reboot the computer. Click OK to continue.

22 The Network Configuration window opens. Select the

Services tab.

23 The Network Services Selection window opens. Highlight the Remove Access Service and click Properties.

28 nextel.com

Installing iDEN Packet Data Applet

24 The Remove Access Service window opens. Click Add.

25 The RAS Device window opens. Verify that the correct

COM port is displayed in the RAS Capable Device box then click OK.

NOTE: If the Motorola iDEN plus Series modem is not displayed in the RAS Capable Device box, click the Install Modem button to install the modem again.

26 The Remote Access Setup window now displays the added

COM port.

27 From the Remote Access Setup window, highlight the

COM port/Device that was just added and click Configure.

The Configure Port Usage window opens. Click on the

Dial out only radio button then click OK.

28 The Remote Access Setup window opens. Click

Continue.

29 Click Close to the Network Services Selection window.

30 Click Finish on the iDEN Packet Data Applet Setup window.

31 The Network Settings change/Computer Restart window opens. Click Yes.

32 The Installshield Wizard window will appear once

Windows has completed the restart process. Click Reinstall

Packet Data Applet icon to proceed with the installation.

NOTE: Check to make sure that your modem is turned on and connected to your computer before continuing with the installation.

RFM-4002-5015 Rev 3 29

iR1200 Modem

30

33 Select the following value on the Communication Settings window:

• Click the Auto Detect to have the software automatically check for the COM Port or select the appropriate COM Port

(typically COM1)

Multiple Baudrate should be unchecked

Baud Rate: 19200 (bps)

The program will check the communication settings and attempt to connect to the modem.

34 The Packet Data Configuration window opens. Select No,

I would like to configure my modem later or my modem

has already been configured then click Next.

35 The Installation Complete window opens. Select Finish on the following screens to complete the installation nextel.com

Installing iDEN Packet Data Applet process.

36 The Setup Complete window opens. Click Finish.

Windows 2000

NOTE: Administrative rights are required to install the software on

Windows 2000. Contact your IT Representative or Systems

Administrator for assistance.

1 Access the Nextel website by entering www.nextel.com.

From the Nextel Home Page, select Services Nextel

Online. The Nextel Online Service Page appears.

2 From the Nextel Online page, find and select Wireless

Web Access PacketstreamGold.

3 The Packetstream Gold Service page appears.

4 Click the Download Packetstream Gold Software (PC

Only) link. The Download Packetstream Gold Software page appears.

5 Scroll down the page to find and select either Nextel

Online Packetstream Gold Service Install link or the

Download Now link located that the bottom of the page.

6 The download program will copy the files that are needed to install the software to the appropriate location on your computer.

IMPORTANT: When you have finished downloading the program, you MUST connect the data cable to your modem and computer before proceeding further.

7 Find the program in the appropriate folder and double-click the Setup.exe to launch the program to initiate the installation process.

NOTE: The setup.exe will be contained in a zip or compressed file.

8 Click Next to accept the default Program Folder, iDEN

Data Modem Applet. The installation program starts and, a

RFM-4002-5015 Rev 3 31

iR1200 Modem

32 status window opens while the files are copying.

9 The Installshield Wizard screen appears during the setup process.

10 Click Next on the iDEN Packet Data Applet Setup screen.

11 The iDEN License Agreement screen appears. Select Yes to accept the terms of the agreement and proceed with the installation.

12 The iDEN Packet Data Applet Setup window will prompt you to enter a Username and Company. Enter the appropriate information and click Next.

13 The Select Program Folder window opens and you are asked to name the destination folder, click Next to accept the default.

14 After the files are copied, the Question window opens. You will be asked if you would like to add the shortcut to your

Windows desktop. Select Yes to add the shortcut

15 The Information window opens. Click Yes to begin installing.

16 An additional Information window opens. Click OK.

17 The Phone and Modem Options window opens with the

Modems tab selected. Click Add.

18 The Add/Remove Hardware window opens. Click the

Don’t Detect my modem; I will select it from a list of checkbox then click Next.

19 The Modem Selection window opens. From

Manufacturers list box, locate and select Motorola and

Motorola iDEN plus Series then click Next.

20 The Port Selection window opens. Highlight the COM port nextel.com

Installing iDEN Packet Data Applet that your modem is connected and click Next.

21 The Digital Signature Not Found window opens. Click

Yes to continue the installation.

22 The Modem Installation Finish window opens. Click

Finish.

23 The Phone and Modem Options window reopens with the

Modems tab selected. Verify that the Motorola iDEN plus

Series modem appears on the list. Click OK.

NOTE: Check to make sure that your modem is turned on and connected to your computer before continuing with the installation.

24 Select the following value on the Communication Settings window:

• Click the Auto Detect to have the software automatically check for the COM Port or select the

RFM-4002-5015 Rev 3 33

iR1200 Modem appropriate COM Port (typically COM1)

Multiple Baudrate should be unchecked

Baud Rate: 19200 (bps)

The program will check the communication settings and attempt to connect to the modem.

25 The Packet Data Configuration window opens. Select No,

I would like to configure my modem later or my modem

has already been configured then click Next.

26 The Installation Complete window opens. Select Finish on the following screens to complete the installation process.

27 The Setup Complete window opens. Click Finish.

34 nextel.com

Setting Up Windows Components

Setting Up Windows Components

In this chapter, you will learn how to set up Windows components and verify their installation.

This chapter includes:

Verifying Dial-Up Networking

Verify TCP/IP Installation

Install Dial-Up Adapter

Page 35

Page 36

Page 39

Verify Dial-Up Networking

This section describes the procedures for verifying dial-up networking on your

Windows computer.

!

If it is determined that your computer does not have dial-up networking, please proceed to the “Manual

Modem Configuration” for instructions on how to install dial-up networking.

Windows 95/98/ME

1 From your desktop, double-click the My Computer icon to open the My Computer window.

2 Double-click the Dial-Up Networking icon to open the

Dial-Up Networking window.

3 Double-click the Make New Connection icon. The Make

New Connection window should appear, indicating that dial-up networking is installed.

4 Click Cancel to close the Make New Connection window.

RFM-4002-5015 Rev 3 35

iR1200 Modem

Windows NT

1 From your desktop, double-click the My Computer icon to open the My Computer window.

2 Double-click the Dial-Up Networking icon to open the

Dial-Up Networking window.

3 The Dial-Up Networking window opens and displays the

Phone book entry to dial heading.

If the Dial-Up Networking window displays the Install prompt then dial-up networking has not been installed.

4 Click Close to close the Dial-Up Networking window.

Windows 2000

1 From your desktop, double-click the My Computer icon to open the My Computer window.

2 Double-click the Control Panel icon. The Control Panel window opens.

3 Double-click the Networking and Dial-Up Connections icon. The Make New Connection window should appear, indicating that dial-up networking is installed.

4 Click Close to close the Network and Dial-up

Connections window.

Verify TCP/IP Protocol Installation

The following table describes the steps for verifying TCP/IP Protocol and Dialup Adapter.

36 nextel.com

Setting Up Windows Components

Windows 95/98/ME

1 From your desktop, double-click the My Computer icon to open the My Computer window.

2 Double-click the Control Panel icon to open the Control

Panel window.

3 Double-click the Network icon to open the Network window.

4 Scroll down the list to find TCP/IP Dial-Up Adapter.

• If you see TCP/IP Dial-Up Adapter in the list, click

OK; you have TCP/IP installed and can proceed with installation.

• If you do not see TCP/IP Dial-Up Adapter in the list, you will need to add the TCP/IP protocol. Click

Add and proceed with the remaining instructions.

5 The Select Network Component Type window opens.

Highlight Protocol and then click Add.

6 The Select Network Protocol window opens. Under

Manufacturer, select Microsoft. Under Network

Protocol, select TCP/IP. Click OK.

7 The TCP/IP Dial-Up Adapter appears in the list.

• If the Dial-Up Adapter appears in the Network

Adapters list, it is installed. You may proceed with installation.

• If the Dial-Up Adapter does not appear in the

Network Adapters list, you do not have a Dial-Up

Adapter installed. Refer to page 38 for instructions for installing Dial-Up adapter.

8 Click OK to close the Select Network Protocol window.

RFM-4002-5015 Rev 3 37

iR1200 Modem

Windows NT/2000

In most cases the TCP/IP protocol was installed automatically. However, for

Windows NT and 2000, TCP/IP may not have been included in the standard installation. The following steps describe how to check that TCP/IP is in fact installed, and if necessary add the TCP/IP protocol.

NOTE: This may require that you contact your IT Representative or

System Administrator.

1 From your desktop, select Start Settings Network and

Dialup Connections Local Area Connection. The Local

Area Connection window opens.

2 Click the Properties button on the Local Area Connection window.

3 Is the Internet Protocol listed under the Components listing?

4 If the Internet Protocol is not listed, click the Install button. The Select Network Component Type window opens.

5 Under Network Component Type listing, highlight

Protocol and click Add.

6 The Select Network Protocol window opens. Under

Network Protocol listing, highlight Internet Protocol and click OK.

7 The installation will now begin — if prompted do NOT restart.

38 nextel.com

Setting Up Windows Components

Installing the Dial-Up Adapter

The following table describes the steps for installing the Dial-Up Adapter.

Windows 95/98/ME

1 From the Select Network Adapter window, highlight

Dial-Up Adapter in the Network Adapters list.

2 Under Manufacturers, highlight Microsoft. Click OK.

3 The Select Network Component Type window opens.

Highlight Adapter. Click Add.

4 The Select Network Adapters window opens.

5 To verify that the adapter was added, from Start, select

Settings.

• Select Control Panel.

• Click Network.

• Look for Dial-Up Adapter on the Network

Configuration screen.

Windows NT/2000

The Dial-Up Adapter may not have been included in the standard installation.

The following steps describe how to check that TCP/IP is in fact installed, and if necessary add the TCP/IP protocol.

NOTE: This may require that you contact your IT Representative or

System Administrator.

1 Select Start Settings Control Panel. The Control

Panel window opens. Double click on Network and Dial

Up Connections.

2 The Network and Dial Up Connections window opens.

Double click on Make New Connection which brings up

RFM-4002-5015 Rev 3 39

iR1200 Modem the connection wizard. Click Next.

3 Select I want to set up my Internet connection manually as above, then click on Next.

4 Select I connect through a phone line and a modem then click on Next.

5 Enter the new phone number:

• Packet Data enter: s=2

• Circuit Switched enter: ISP Phone Number

Click on the Advanced button.

6 The Advance Connection Properties window opens. On the Connection tab, select PPP and for Logon procedure select None.

7 Click on the Addresses tab. Select My ISP automatically

provides... Click on OK to return to the phone number screen. Click on Next to continue.

8 Enter your username and password then click Next.

9 Enter a connection name such as “iR1200 Modem” or

“iDEN Connection” and then click Next.

10 Select No and click Next. Click on Finish to complete the setup.

40 nextel.com

Manual Modem Configuration

Manual Modem Configuration

In this chapter, you will learn how to manually add a modem, configure the modem drivers and create a dial-up networking connection for Nextel.

NOTE: Use these instructions only if you did not previously install the iDEN Packet Data Applet.

This chapter includes:

Modem Configuration – Windows 95/98/ME

Modem Configuration – Windows NT 4.0

Modem Configuration – Windows 2000

Page 41

Page 44

Page 48

Modem Configuration – Windows 95/98/ME

Install the Modem

1 Go to Start Settings Control Panel and click on the

Modems icon.

2 The Modem Properties window opens. Select the General tab and click Add.

3 The Install New Modem window opens. Select Other.

Click Next.

4 The Install New Modem/Hardware Installation window opens. Check the Don’t run the Hardware Installation

Wizard box. Click Next.

NOTE: If this option is not available, proceed to the next step.

5 The Install New Modem/Modem Detection window opens. Check the Don’t detect my modem; I will select

RFM-4002-5015 Rev 3 41

iR1200 Modem

from a list box. Click Next.

6 The Install New Modem/Modem Selection window opens. Under Manufacturer, select Standard Modem

Types. Under Models, click Standard 19200 bps Modem.

Click Next.

7 Select the COM port that you will be using to connect to the modem (i.e., COM1, COM2, or COM3), then click Next.

NOTE: If you are not sure which COM port to use, begin with

COM1. If you are unable to connect to a network using COM1, you will need to reinstall the modem after attaching the modem to a different COM port.

8 The Install New Modem/Modem Installation Finish window opens. Click Finish.

9 Continue with the steps to Configure the Modem Driver.

Configure the Modem Driver

1 From the Modems Properties window, select Standard

19200 bps Modem. Click Properties.

2 The Standard 19200 bps Modems Properties window opens. On the General tab, confirm the Maximum Speed is 19200 bps.

3 Click the Connection tab and verify the following settings:

Data Bits: 8

Parity: None

Stop Bits: 1

Click Advanced.

4 The Advanced Connection Settings window opens. If they are not selected already, select the following:

42 nextel.com

Manual Modem Configuration

Use Flow Control and

Hardware (RTS/CTS)

• If the Duplex option is present, select Full.

5 Click OK to close the Advanced Connection Settings window.

6 Click OK (or Close) to close the Standard 19200 bps

Modem’s Properties window.

7 Click Close to close the Modem’s Properties window.

8 Click Close to close the Control Panel.

9 Continue with the steps to Create a Dial-Up Networking

Connection.

Create a Dial-up Networking Connection

1 With the My Computer window open, double-click the

Dial-Up Networking icon.

2 The Dial-Up Networking window opens. Double-click

Make New Connection.

3 The Make New Connection window opens. Enter a name for the connection, such as iR1200 Modem. Under Select a

device, use the drop-down box to locate and select

Standard 19200 bps Modems. Click Next.

4 The Make New Connection window changes and now displays fields for entering the phone number. Delete any information contained in the Area Code box.

• For Packet Data: At Telephone number, enter s=2.

• For Circuit Switched Data: Enter the ISP phone

number.

Click Next.

5 The Setup Finish window opens, click Finish. This

RFM-4002-5015 Rev 3 43

iR1200 Modem procedure creates the iR1200 Modem icon in the Dial-Up

Networking window.

6 In the Dial-Up Networking window, right click iR1200

Modem. Click Properties.

7 The iR1200 Modem Network window opens. Click the

Server Types tab.

NOTE: For packet data, country code and area code (under the

General Tab) should always be blank to allow s=2 to be the telephone number.

8 Under Type of Dial-Up Server, select PPP.

Under Allowed Network Protocols, ensure that the box next to TCP/IP is checked. Remove the check marks from all other selection boxes.

Click the TCP/IP button.

9 The TCP/IP Settings window opens. Ensure that the following are checked:

Server assigned IP address

Server assigned name server addresses

Use IP header compression

Use default gateway on remote network

All other boxes should remain unchecked. Click OK.

10 Click OK to complete the set up

Modem Configuration – Windows NT

Install the Modem

1 Go to Start Settings Control Panel and click on the

Modems icon.

44 nextel.com

Manual Modem Configuration

2 The Modems Properties window opens. Under the

General tab click Add.

3 The Install New Modem window opens. Select Other then

Next.

4 The Install New Modem/Hardware Installation window opens. Check the Don't run the Hardware Installation

Wizard box. Click the Next button.

NOTE: If this option is not present, proceed to the next instruction.

5 The Install New Modem/Modem Detection window opens. Check the Don't detect my modem; I will select it

from a list box. Click Next.

6 The Install New Modem/Modem Selection window opens. Under Manufacturer, select (Standard Modem

Types). Under Models, click Standard 19200 bps

Modem. Click Next.

7 The Port Selection window opens. Highlight the COM port that you will be using to connect to the phone. Click Next.

8 The Modem Installation Finish window opens. Click

Finish.

9 The Modems Properties window reappears with the newly added Standard 19200 bps modem displayed in the dialog box. Click Close.

10 The following message appears: Dial-Up Networking needs to be configured because the list has changed. Do

you wish to reconfigure? Click Yes.

11 The Remote Access Setup window opens. Click Add.

NOTE: In Windows NT, only one modem can be installed per

COM port. If you are attempting to install the Standard 19200 bps modem on a COM port to which another modem is directed, you must choose an alternate COM port or remove the other modem before proceeding. Otherwise a conflict will

RFM-4002-5015 Rev 3 45

iR1200 Modem occur and Windows NT will not recognize the Standard 19200

bps modem.

12 The Add RAS Device window opens. Make sure the proper

COM port for your modem connection is selected. Click

OK.

13 The Remote Access Setup window now shows the added

COM port. Click Continue.

14 The system automatically configures the appropriate settings.

15 Continue with the steps to Configure the Modem Driver.

Configure the Modem Driver

1 From the Modems Properties window, select the

Standard 19200 bps Modem. Click Properties.

2 The Standard 19200 bps Modems Properties window opens. On the General tab, confirm the Maximum Speed is 19200 bps.

3 Click the Connection tab and verify the following settings:

Data Bits: 8

Parity: None

Stop Bits: 1

Click Advanced.

4 The Advanced Connection Settings window opens. If they are not selected already, select the following:

Use Flow Control and

Hardware (RTS/CTS)

• If the Duplex option is present, select Full.

46 nextel.com

Manual Modem Configuration

5 Click OK to close the Advanced Connection Settings window.

6 Click OK (or Close) to close the Standard 19200 bps

Modems Properties window.

7 Click Close to close the Modem's Properties window.

8 Click Close to close the Control Panel.

9 Continue with the steps to Create a Dial-Up Networking

Connection.

Create a Dial-up Networking Connection

1 With the My Computer window open, double-click the

Dial-Up Networking icon.

2 The Dial-Up Networking window opens. Click New.

3 The New Phonebook Entry Wizard window opens. Enter a name for the phonebook entry such as iR1200 Modem.

Click Next.

4 The Server window opens. Check the box next to I am

calling the Internet. Click Next.

5 The Modem or Adapter window opens. Select the

Standard 19200 bps Modem. Click Next.

6 The Phone Number window opens. In the Phone number box, enter the following:

• For Packet Data: s=2

• For Circuit Switched Cellular: ISP Phone Number.

Click Next.

7 The Wizard Finish window opens. Click Finish.

8 The Dial-Up Networking Phonebook window opens with the iR1200 Modem entry displayed. Click More and select

RFM-4002-5015 Rev 3 47

iR1200 Modem

Edit entry and modem properties from the drop-down list.

9 The Edit Phonebook Entry window displays. Click the

Server tab.

10 In the Dial-up server type, select PPP. Under Network

protocols, check the box next to TCP/IP. Remove the check marks from all other selection boxes. Click the

TCP/IP button.

11 The PPP TCP/IP Settings window opens. Ensure that the following are checked:

Server assigned IP address

Server assigned name server addresses

Use IP header compression

Use default gateway on remote network

All other boxes should remain unchecked. Click OK.

12 Click OK to complete the set up.

Modem Configuration – Windows 2000

Install the Modem

1 Go to Start Settings Control Panel and click on the

Phone and Modem icon.

2 The Phone and Modem Options window opens. Click the

Modems tab.

3 The Modems window opens. Click Add.

4 The Install New Modem window opens. Check the Don't

detect my modem; I will select if from a list box then click Next.

48 nextel.com

Manual Modem Configuration

5 The Modem Detection window opens. Under

Manufacturer, select (Standard Modem Types). Under

Models, click Standard 19200 bps Modem. Click Next.

6 The Port Selection window opens. Highlight the COM port that you will be using to connect to your modem (i.e.,

COM1, COM2, COM3, etc.). Click Next.

7 The Digital Signature Not Found window opens. Click

Yes to proceed.

8 The Modem Installation Finish window opens. Click

Finish.

9 The Modems window reappears with the newly added

Standard 19200 bps modem displayed in the dialog box.

Click OK.

Create and Configure a Dial-up Networking Connection

1 From the computer’s desktop, double-click the My

Computer icon. Then, double-click the Control Panel icon.

2 The Control Panel window opens. Double-click on the

Network and Dial-up Connections icon.

3 The Network and Dial-up Connections window opens.

Double-click on Make New Connection.

4 The Network Connection Wizard window opens. Click

Next.

5 The Network Connection Type window opens. Select

Dial-up to the Internet and click Next.

6 The Welcome to the Internet Connection Wizard opens.

Select I want to set up my Internet connection manually, or I want to connect through a Local Area Network

(LAN) and click Next.

RFM-4002-5015 Rev 3 49

iR1200 Modem

50

7 The Setting up your Internet connection window opens.

Select I connect through a phone line and a modem and click Next.

8 The Choose Modem window opens. From the drop-down box, select Standard 19200 bps Modem and click Next.

9 The Internet Connection, Step 1 window opens. Enter a temporary telephone number (this phone number will be modified in Modem Properties later in the configuration).

Make sure that the Use area code and dialing rules is

NOT checked. Click Advanced.

10 The Advanced Connection Properties window opens with the Connection tab selected. Verify the following settings:

Under Connection type:

PPP (Point-to-Point Protocol) – should remain checked

Disable LCP Extensions – should remain checked

SLIP – should remain unchecked

C-SLIP – should remain unchecked

Under Logon procedure:

None – should remain checked

Log on manually – should remain unchecked

Use logon script – should remain unchecked.

11 Click the Addresses tab and verify the following settings:

Under IP address:

Internet service provider automatically provides

one –should remain checked nextel.com

Manual Modem Configuration

Always use the following – should remain unchecked

Under DNS server address:

My ISP automatically provides a DNS address – should remain checked

Always use the following – should remain unchecked.

Click OK.

12 The Internet Connection, Step 2 window opens. User name and password are not required fields. Click Next. You will receive two warning boxes asking if you want to continue with a blank user name and a blank password.

Click Yes on both boxes.

13 The Internet Connection, Step 3 window opens. Enter a name for the connection, such as iR1200 Modem. Click

Next.

14 The Set Up Your Internet Mail Account window opens.

Select No (optional) and click Next.

15 The Completing the Internet Connection Wizard window opens. Click Finish.

Modify Dial-up Connection Parameters

1 From the computer’s desktop, double-click the My

Computer icon. Then, double-click the Control Panel icon.

2 The Control Panel window opens. Double-click on the

Network and Dial-up Connections icon.

3 The Network and Dial-up Connections window opens with the new iR1200 Modem icon inside.

4 Right-click on the iR1200 Modem connection icon and select Properties.

RFM-4002-5015 Rev 3 51

iR1200 Modem

5 The iR1200 Modem window opens. Select the General tab. In the Phone number box, erase the temporary phone number previously entered:

• For Packet Data enter: s=2

• For Circuit Switched Cellular enter: the ISP phone number

Click OK.

52 nextel.com

Modem Profiles and Settings

Modem Profiles and Settings

In this chapter, you will learn how to use AT commands to setup parameters and configure the iR1200 modem for usage.

This chapter includes:

HyperTerminal Setup

Opening HyperTerminal Session

Configuring with AT Commands

Modem Initialization

Restore Defaults

Activate DTR Monitoring

Activate DCD Management

Set Computer’s IP Address

Select iDEN Packet Wireless Data

Select SLIP or PPP

Mobile IP Activation

Mobile IP Home Agent Address

Mobile IP Authentication Key

Mobile IP Security Parameter Index (SPI)

Mobile Node IP Prefix Length

Header Compression

Saving AT Settings

GPS Default Parameters

Page 54

Page 56

Page 57

Page 57

Page 57

Page 58

Page 58

Page 58

Page 59

Page 59

Page 60

Page 60

Page 60

Page 61

Page 61

Page 62

Page 62

Page 63

RFM-4002-5015 Rev 3 53

iR1200 Modem

HyperTerminal Setup

A HyperTerminal session must be setup for you to enter AT commands.

The following table outlines steps to setup a HyperTerminal session for the iR1200 modem:

1 From your computer, locate and select the HyperTerminal program.

2 The Connection Description screen appears.

54

3 Type a description of the connection in the Name: box.

4 Select the dial function (red and yellow phone icon) and click OK.

5 The Connect To screen appears. nextel.com

Modem Profiles and Settings

6 Select the appropriate communication port (typically

COM1) from the “Connect Using:” drop-down list then

Click OK.

7 The COM1 Properties screen appears.

8 Select the following parameters from each of the dropdown list on the Port Settings tab:

Bits Per second: 19200

Data Bits: 8

RFM-4002-5015 Rev 3 55

iR1200 Modem

Parity: None

Stop Bits: 1

Flow Control: Hardware

9 Click OK when all the parameters have been selected.

10 Test to make sure that you have established communication with the modem by typing the AT command “ ATi4” and pressing Enter.

11 You should see a message “Nextel, iDEN OK” or “Nextel,

iDEN 0”.

Opening a HyperTerminal Session

The following table describes steps to start a HyperTerminal Session:

1 Windows 2000/XP/Windows 98:

Start Programs Accessories Communications Hyper

Terminal.

2 Windows NT:

Start Programs Accessories HyperTerminal HyperT erminal

3 The HyperTerminal window will open. You are now ready to issue AT commands to the Modem.

56 nextel.com

Modem Profiles and Settings

Configuring With AT Commands

Modem Initialization

The iR1200 modem’s factory default image 2 is configured to start up with packet data. If you are using circuit switched data, we recommend that you

Step 1 – Backup image 2 (default) to image 1

AT Command Save User Default profile 2 to profile 1

Command Syntax AT&W1

Expected Return Code(s) OK

Step 2 – Change default call setting (packet data) to circuit switched

AT Command Change Call Setting Parameter

Command Syntax ATZ0

Expected Return Code(s) OK

Step 3 – Save new setting as default profile.

AT Command Save User Default

Configuration

Command Syntax AT&W2

Expected Return Code(s) OK

Restore Factory Defaults

To ensure a clean configuration process, you should restore the current values to their factory default values by applying the following.

AT Command Restore Factory-Default

RFM-4002-5015 Rev 3 57

iR1200 Modem

Command Syntax

Configuration

AT&F

Expected Return Code(s) OK

Activate DTR Monitoring

The DCE does not monitor the DTR line of the DTE/DCE physical connection.

This is the default factory setting. To activate DTR monitoring in the DCE, you must apply the following command.

AT Command DTR Behavior

Command Syntax AT&D2

Expected Return Code(s) OK

Activate DCD Management

The factory default for the modem keeps the Data Carrier Detect (DCD) line of the computer-to-modem physical connection active at all times. Some communication programs monitor this line to determine the status of the connection. To promote compatibility with these programs, enable DCD management in the modem.

AT Command DCD Behavior

Command Syntax AT&C1

Expected Return Code(s) OK

Set Computer’s IP Address

Inform the modem of the computer’s IP address to establish SLIP or PPP connection between the modem and the computer.

AT Command

Command Syntax

Computer IP Address

AT+WPNEI=XXX.XXX.XX,

58 nextel.com

Modem Profiles and Settings

0,0,0

(Insert appropriate IP address where X appears.)

Expected Return Code(s) OK

!

IMPORTANT INFORMATION: Customers cannot ping a

Non Routable IP address when provisioned due to the

NAT (Network Address Translator) Server. This server attaches a Class C Public IP Address to a Private

Class A Non Routable IP address for a specific period of time to browse the public internet. This Class C address is needed in order to route on the public internet, as Non-Routable IPs are for internal routing only (Intranet).

Select iDEN Packet Wireless Data

The iR1200 modem supports multiple wireless data formats. Select the desired data service by applying the following command.

AT Command Select WDS-side stack

Command Syntax AT+WS46=24

Expected Return Code(s) OK

Select SLIP or PPP

By default, the modem attempts to establish a PPP connection. To specify the type of connection the modem will establish, apply the following command

AT Command Select computer-side stack

Command Syntax AT+WS45=4 (PPP)

AT+WS45=3 (SLIP)

Expected Return Code(s) OK

RFM-4002-5015 Rev 3 59

iR1200 Modem

Mobile IP Activation

The modem makes use of mobile IP to manage a truly mobile computer. You may use a Mobile IP stack on the computer or use the Mobile IP stack built into the modem.

By default, the modem is configured to work with a third-party stack. If you desire this mode of operation, skip ahead to the “Configure Encryption

Settings”. Otherwise, you must activate the Mobile Node functionality within the modem as well the security-related parameters.

NOTE: The Data Terminal Equipment (DTE) uses a TCP/IP stack to format the data message with standard TCP/IP protocols used on the Internet. The iR1200 modem does not have a TCP/IP stack. The “mobile-IP stack” capability of the iR1200 is required to transmit data on the iDEN network.

AT Command

Command Syntax

Modem Mobile IP Control

AT+WV300=1 (activate)

AT+WV300=0 (deactivate)

Expected Return Code(s) OK

Mobile IP Home Agent Address

You must supply the IP address for the Home Agent. This is accomplished by applying the following command

AT Command MIP Home Agent Address

Command Syntax AT+WV305=XXX.XXX.XX

(Insert appropriate IP address where X appears.)

Expected Return Code(s) OK

Mobile IP Authentication Key

The Mobile IP Authentication Key is used as a PIN number to validate your

Mobile IP connection with the Home Agent.

60 nextel.com

Modem Profiles and Settings

AT Command MIP Authentication Key

Command Syntax AT+WV301=”AAAXXX”

(Make sure that the

Authentication Key Name is entered with the quotation mark. Substitute the values within the quotation with the one supplied by your system administrator or service provider.)

Expected Return Code(s) OK

Mobile IP Security Parameter Index (SPI)

The SPI is similar to the Authentication Key in that the modem and the home

Agent must have identical values registered for the computer.

AT Command MIP Security Parameter Index

Command Syntax AT+WV309=XXX

(Insert appropriate SPI where X appears, the SPI can be obtained from your system administration or service provider.)

Expected Return Code(s) OK

Mobile Node IP Prefix Length

The IP address prefix length is the number of contiguous bits that make up the network prefix of that address. This command allows you to specify the prefix length of the computer’s IP address.

AT Command Mobile Node IP Prefix Length

Command Syntax AT+WV311=X

RFM-4002-5015 Rev 3 61

iR1200 Modem

(Insert appropriate prefix length where X appears.)

Expected Return Code(s) OK

Header Compression

This command enables or disables TCP header compression options. Some

DTE-side stacks (such as PPP) will negotiate local header compression independently from this setting. To disable header compression, apply this command.

AT Command Header Compression

Command Syntax AT+ws182=<header compression>

AT+ws182? (?=Query parameter)

AT+ws182=? (?=Range

Parameter)

Parameter Value 0 = over the air and local header compression enabled.

1 = over the air header compression enabled.

2 = Local header compression enabled

3 = header compression disabled.

Expected Return Code(s) OK

Saving AT Settings

Your modem is now properly configured for Nextel’s iDEN network.

62 nextel.com

Modem Profiles and Settings

IMPORTANT: These settings are stored on the modem’s Random

Access Memory (RAM) and are lost when the modem is turned off unless stored in the modem’s non-volatile memory.

The iR1200 modem can store up to three profile or image. By default, image 2 is loaded when the modem is powered on. We recommend that you save this setting to the first profile/image.

AT Command Save User Default

Configuration

Command Syntax AT&W1

Expected Return Code(s) OK

GPS Default Parameters

The iR1200 GPS-Enabled modem will use the following NMEA default parameters.

The factory default port characteristics are:

• Baud rate = 4800 bps

• Data bits = 8

• Stop bits = 1

• Parity = None

Note: These settings should not be changed unless absolutely necessary.

RFM-4002-5015 Rev 3 63

iR1200 Modem

64 nextel.com

AT Commands

AT Commands

This chapter describes common AT commands that can be applied to the iR1200 modem.

This chapter includes:

General AT Commands

User Image Profile Commands

Registration, Reset, and Authentication

Commands

Network Status Commands

Other Useful Commands

Page 65

Page 66

Page 66

Page 66

Page 67

General AT Commands

Command

AT

ATEx

AT&V

AT+IPR

Usage

AT

ATE0 or ATE1

Action

Checks communication.

Sets echo on or off.

AT&V Displays modem parameters.

AT+IPR = baud rate Sets the modem’s baud rate.

RFM-4002-5015 Rev 3 65

iR1200 Modem

User Image Profile Commands

Command

ATz

Usage

ATz0, ATz1, or

ATz2

AT&Wx AT&W0, 1, or 2.

Action

Sets the specified image as the active image.

Writes active image to the specified profile

Registration, Reset, and Authentication Commands

Command

AT+wvreset

Usage

AT+wvreset

Action

Resets the modem and performs power cycle.

Mater Resets the modem. AT+wvmr

AT+wvcsk

AT+wvmr=’xxxx’

(0000)

AT+wvcsk=’xxxx’

(0000)

AT+wvrsk AT+wvrsk=’xxxx’

(0000)

AT+WPDEREG AT+WPDEREG

AT+WPREG AT+WPREG

Changes authentication service key.

Resets the service key to all 0’s.

Forces modem to deregister.

Forces mode to register

Network Status Commands

Command Usage Action

66 nextel.com

AT Commands

AT+WS53?

AT+WS50?

AT+WS53?

AT+WS50?

AT+WPSTATE AT+WPSTATE

Checks Signal Quality

Check Signal Strength

Checks mobile IP registration

DTE IP Address AT+WPREG AT+WPREG

Other Useful AT Commands

The following table outlines other common AT commands for your reference.

Answer

This command instructs the DCE to immediately connect to the call and start the answer sequence, as appropriate for the selected service.

A Command

Action ATa

Query

Range

Command Mode Echo

The setting for this parameter determines whether or not the DCE echoes characters received from the DTE during command state and online command state.

Command

Action ATe <echo>

Query

Range

AT&v

E

Parameter 0 = Disabled command mode character echo.

RFM-4002-5015 Rev 3 67

iR1200 Modem

Values:

1 = Enabled command mode character echo.

Dial

This command instructs the DCE to originate a call. When the DCE receives the dial string from the computer, all non-numeric characters in the Dial String that are not recognized dial-modifiers are ignored. This allows the DTE to request modem numbers containing unsupported dial modifiers, hyphens, parenthesis, and other punctuation.

Command

Action ATd <Dial String>

Query

Range

Parameter

Values

(dial modifiers)

:

D

Dial string contains a modem number to be dialed, translated into an array of ASCII characters between 0 and 9 inclusive

T = Allowed, but ignored by the modem.

P = Allowed, but ignored by the modem.

! = Hook Flash (1/2 second).

W = Wait for time specified in S7 for dial tone.

(blank) = Wait for time specified in S7 for one or more rings followed by five seconds of silence before continuing execution of dial string.

, = Pause for time specified in S8

; = After dialing return to command mode.

68 nextel.com

AT Commands

Hang-up

This command instructs the modem to terminate the active call.

H Command

Action ATh

Query

Range

Request Modem Information

This command causes the modem to issue a string to provide product information.

Command

Action ATi <request>

Query

Range

Parameter

Values:

0 = OK Response code

I

1 = iDEN DTE/DCE Specification Version

2 = Software Model

3 = Product Model

4 = Product Manufacturer

Go Online

This command causes the modem to enter the online state from the online command state.

Command

Action Ato

O

RFM-4002-5015 Rev 3 69

iR1200 Modem

Query

Range

Pulse Dialing

This command selects pulse dialing. It is provided for compatibility purposes.

P Command

Action Atp

Query

Range

Quiet Mode

This command controls whether or not the result codes are sent to the computer. If turned on, the Result Code Format and Extended Result code commands may further modify the result codes.

Q Command

Action ATq <setting>

Query

Range

Parameter

Values:

0 = Result codes sent

1 = Result codes not sent

Tone Dialing

This command selects DTMF dialing. It is provided for compatibility purposes and has no processing effect.

Command T

70 nextel.com

AT Commands

Action

Query

Range

ATt

Verbose Result Codes

This command sets your preference for the result code format. It allows the computer to select either Terse or Verbose result code formats.

Command

Action ATv <setting>

Query

Range

Parameter

Values:

AT&v

V

0 = Numeric result code format

1 = Verbose result code format

Extended Result Codes

This command provides an extended result code selection.

Command

Action ATx <setting>

Query AT&v

Range

Parameter

Values:

X

0, 1 = The modem does not return the BUSY or NO

DIALTONE result codes.

2 = The modem might return the NO DIALTONE result code if appropriate, but does not return the BUSY result code.

3 = The modem may not return the BUSY result code, if

RFM-4002-5015 Rev 3 71

iR1200 Modem appropriate, but does not return the NO DIALTONE result code.

4 = The modem may return either the BUSY or NO

DIALTONE result code, if appropriate.

Restore User Defaults

This command causes the modem to reset all parameters and S-registers to their user-defined default values. There are three sets of user defaults (or images).

The parameter selects between which image is being requested.

Z Command

Action Atz <image>

Query

Range

Parameter

Values:

0 = Local user image 0

1 = Local user image 1

2 – Local user image 2

DCD Behavior

This parameter determines how the DCD line relates to the detection of received line signals from the distant end.

!

Changing the parameter takes effect immediately in both the command and online command states.

Command

Action AT&c <setting>

Query AT&v

&C

72 nextel.com

AT Commands

Range

Parameter

Values:

0 = DCD always on

1 = The modem turns on the DCD to indicate the presence of a connection, and turns off the DCD to indicate the loss of connection.

DTR Behavior

This parameter determines how the computer responds when the DTR line is changed from the ON condition to the OFF condition during the online data state.

Command

Action AT&d <setting>

Query

Range

Parameter

Values:

AT&v

&D

0 = Modem ignores DTR

1 = If the DTR is turned ON while in online data mode, the mode returns the command mode and issues the OK result code. The call remains connected.

2 = If the DTR is turned OFF while in online data mode, the modem disconnects the call and returns the OK result code. If DTR is OFF while in command mode, the modem will not answer an incoming call, regardless of the setting, S0 (automatic answer).

Restore Factory Default

This command causes the modem to reset all parameters and S-registers to their factory defined default value. The optional parameter value, if present must be

0.

Command &F

RFM-4002-5015 Rev 3 73

iR1200 Modem

Action

Query

Range

AT&f <setting>

AT&v

Local Flow Control (Traditional)

This parameter selects the type of flow control used between the computer and the modem while in data transfer mode. This command is supported for backward compatibility purposes. This command sets the method of flow control for both directions of the computer-to-modem interface, while the +IFC command allows for a separate setting for each direction.

!

The setting for this command may implicitly alter the settings of the +IFC command.

Command

Action AT&k <setting>

Query

Range

Parameter

Values:

&K

0 = No Flow Control (not recommended)

3 = RTS/CTS Flow Control.

4 = XON/XOFF Flow Control.

Display Current Parameter Value

This command allows the computer to view the parameter and S-register settings for the active configuration profile.

Command

Action AT&fv <setting>

&V

74 nextel.com

AT Commands

Query

Range

Local Character Framing

This parameter determines the local serial port asynchronous data framing. The second parameter is needed only if you select fewer than eight data bits.

Command

Action

&ICF

AT+icf <framing>, <parity>

Query

Range

Framing

Parameter

Values:

Parity

Parameter

Values:

AT+icf?

AT+icf?

0 = AutoDetect

3 = 8 data bits, 1 stop bit

5 = 7 data bits, 1 parity bit, 1 stop bit

0 = Odd

1 = Even

2 = Mark

3 = Space

Local Flow Control (PCCA)

This extended compound parameter controls, the local flow control between the computer and the modem. The two numeric sub-parameters are DCE_by_ DTE

(which controls the data format he modem) and DTE_by_DCE (which controls the data from the computer).

NOTE: To change the setting of these parameters, use the &K command.

Command

Action

+IFC

AT+ifc <DCE_by_DTE>, <DTE_by_DCE>

Query

Range

AT+ifc?

AT+ifc=?

RFM-4002-5015 Rev 3 75

iR1200 Modem

DCE_by_

DTE

Parameter

Values:

DTE_by_

DCE

Parameter

Values:

0 = No flow control was set by DTE.

1 = XON/XOFF; do not pass XON/XOFF characters to the remote DCE.

2 = RFR active/inactive flow control

3 = XON/XOFF; Pass DC1/DC3 characters to the remote DCE in addition to acting upon local flow control.

0 = No flow control was set by DTE.

1 = XON/XOFF flow control

2 = CTS/RFS active/inactive flow control

Local Data Rate

This numeric extended-format parameter specifies the data rate between the

DTE and the DCE.

76

Command

Action AT+ipr=<rate>

Query

Range

Parameter

Values:

AT+ipr?

AT+ipr=??

+IPR

0 = Automatic detection on baud rate, data framing

300 = Transmission speed in bits per second.

2400 = Transmission speed in bits per second.

4800 = Transmission speed in bits per second.

9600 = Transmission speed in bits per second.

19200 = Transmission speed in bits per second. nextel.com

AT Commands

38400 = Transmission speed in bits per second.

57600 = Transmission speed in bits per second.

115200 = Transmission speed in bits per second.

Lock/Unlock the DCE

When the DCE is locked, communication over the serial port to the modem is suspended.

NOTE: If the PIN was removed (by setting its value to the empty string

(“ ”), the DTE must still specify the PIN, represented by the empty string.

Command

Action

+WCLK

AT+wclk=<LockStatus>, <PIN>

Query

Range AT+WCLK=?

Parameter

Values –

Lock

Status:

0 = Unlock the DCE

1 = Lock the DCE

PIN

A PIN is stored as a series of alphanumeric characters, with a maximum length of 8 characters. If more than 8 characters are set as a PIN, only the first 8 are recognized.

Change the DCE’s PIN.

This command sets the PIN that locks or unlocks the DCE.

NOTE: You must specify the desired PIN, as well as the current PIN.

The factory-default PIN is the “empty string” or a value of “ ”.

RFM-4002-5015 Rev 3 77

iR1200 Modem

Command

Action

+WCPN

AT+wcpn=<newPIN>, <oldPIN>

Query

Range

Parameter

Values:

AT+wcpn=?

A PIN is stored as a series of alphanumeric characters, with a maximum length of 8 characters. If more than 8 characters are set as a PIN, only the first 8 are recognized.

Packet Data Sleep Timer

This timer controls the length of time the DCE stays on a packet channel though no traffic is actively being transferred.

Command

Action AT+ws175<timer>

Query

Range

Parameter

Values:

AT+ws175?

AT+ws175=?

0 = Disable sleep timer

+WS175

5-255 = Seconds before sleeping

10 = Default value

SLIP MTU

This setting specifies the Maximum Transmitted Unit used by SLIP connections. (PPP Connections negotiates this value).

Command

Action AT+wv312=<MTU>

+WV312

78 nextel.com

AT Commands

Query

Range

Parameter

Values:

AT+wv312?

AT+wv312=?

68-1500 = MTU Value Range

1006 = Default Value

Select Mobile IP Client

This parameter activates/deactivates the Mobile Node client in the DCE. The mobile host can operate in two modes to access the iDEN packet data network.

Command

Action AT+wv300<MIP Mode>

+WV300

Query AT+wv300?

Range

Parameter

Values:

AT+wv300=?

0 = Activate Mobile Node in DCE.

1 = Deactivate Mobile Node in DCE.

Mobile IP Authentication Key

The iDEN network uses the MIP Authentication Key to verify the authenticity of the DCE with the Home Agent. The DCE and the Home Agent must have identical values for this shared secret key for the DCE to satisfy the authentication process.

NOTE: This command is applicable only when the Mobile IP Client in the DCE is activated.

Command

Action

Query

AT+wv301<”key”>

+WV301

Range AT+wv301=?

RFM-4002-5015 Rev 3 79

iR1200 Modem

Parameter

Values:

The authentication Key parameter is a text string of up to 32 characters. Unlike most text-string parameters, the

Authentication key is a text representation of a hexadecimal number. Therefore, only the characters 0-9 and A-F are acceptable. (The lower case character, a-f is also acceptable).

NOTE: Although the parameter represents a numeric value, the parameter is actually a text string, so the parameter must be enclosed in quotation marks.

Mobile IP Session Timer

The command determines the maximum amount of time that a remote node can be registered with its Home Agent before having to renew its registration. This parameter sets a user preference for a value that is negotiated within the network. During the negotiation process, the user preference may be overruled by the network without notification.

Command

Action AT+wv302<timer>

Query AT+wv302?

AT+wv302=? Range

Parameter

Values:

+WV302

1800-65534 = Second before expiration

65536 = Timer never expires

7200 = Default value

DTE IP Address

This command sets the mobile node’s permanent IP Address (also known as the network Entry Identified, or NEI).

80 nextel.com

AT Commands

NOTE: This parameter is applicable only when the Mobile Node Client in the DCE is activated.

Command

Action AT+wpnei<”address”>

+WPNEI

Query

Range

Parameter

Values:

AT+wpnei?

AT+wpnei=?

An IP Address consists of up to 15 characters, and is in the format “ddd.ddd.ddd.ddd”.

0.0.0.0. = Default value

DTE IP Address Prefix Length

The prefix-length is the number of contiguous bits in an IP address that makes up the network prefix (or network number plus subnet number) of the IP address.

NOTE: This command sets the prefix length of the Mobile Node’s IP address, as specified by +WPNEI.

Command

Action

Query

Range

Parameter

Values:

AT+wv311<length>

AT+wv311?

AT+wv311=?

2-24 = Prefix length

2 = Default value

+WV311

Data Encryption

The DTE uses this command to select whether or not to encrypt the air-link interface and determines how the air-link is encrypted. Encryption is negotiated during the packet data registration.

RFM-4002-5015 Rev 3 81

iR1200 Modem

Command

Action

+WV308

AT+wv308<encryption>, <firm offer>, <key size>

Query

Range

AT+wv308?

AT+wv308=?

0 = Disabled

1 = Vancouver Encryption

Parameter

Values -

Encryption:

Parameter

Values –

Firm Offer:

Parameter

Value –

Key Size:

0 = Encryption setting is a negotiable preference.

1 = Encryption setting is not negotiable.

40-64 = Encryption key size

40 = Default value

DTE Stack

This command sets the protocol for communication between the DEC and the

DTE. Circuit-switched data connections allow only the transparent character stream for packet data connections; use SLIP or CSLIP or PPP.

Command

Action AT+ws45<stack>

Query

Range

Parameter

Values:

AT+ws45?

AT+wv45=?

+WS45

0 = Transparent Character Stream

1 = Reliable Transparent Character Stream (TMOL)

3= SLIP/CSLIP

4 = PPP

82 nextel.com

AT Commands

WDS Stack

This command changes the data mode of the modem between circuit-switched data and packet data.

Command

Action AT+ws46<service>

Query

Range

Parameter

Values:

AT+ws46?

AT+wv46=?

+WS46

23 = iDEN Circuit-switched data/fax

24 = iDEN packet data

252 = Local Data Services

Service Class

This command switches between normal circuit-switched data mode and Class

2 fax mode. This setting has no effect during the packet data service.

Command

Action AT+fclass<class>

Query

Range

Parameter

Values:

AT+fclass?

AT+fclass=?

+FCLASS

0 = Class 0 operation (modem operation)

2 = Class 2 operation (fax operation)

8 = Class 8 (voice operation – while tethered)

Packet Data Registration Timeout

This command allows the DTE to specify a maximum amount of time to wait for packet data operation.

Command +WS198

RFM-4002-5015 Rev 3 83

iR1200 Modem

Action

Query

Range

Parameter

Values:

AT+ws198<time>

AT+ws198?

AT+ws198=?

1-255 = Seconds

30 = Default value

Circuit Data Auto-Answer

This command determines if and when the DCE should automatically answer an incoming call.

Command

Action AT+s0<rings>

Query AT+s0?

Range

Parameter

Values:

AT+s0=?

S0

0 = Do not automatically answer incoming calls

1-255 = Answer after specified number of rings

Circuit Data Establishment Timeout

This command allows the DTE to specify the maximum amount of time between a request for a circuit data connection and the establishment of this connection.

S7 Command

Action AT+s7<timer>

Query

Range

AT+s7?

AT+s7=?

84 nextel.com

AT Commands

Parameter

Values:

1-255 = Seconds

30 = Default value

Comma Dial Modifier Timer

This command allows the DTE to set the duration of the pause associated with a comma (,) dial modifier.

S8 Command

Action AT+s8<timer>

Query AT+s8?

Range

Parameter

Values:

AT+s8=?

0-255 = Seconds

2 = Default value

Circuit Data Idle Timer

This command specifies an idle line timeout for online data mode. If no data is sent by the DTE on the transmit data line for the specified period of time, the

DCE disconnects the call, returns the OK result code, and returns to command mode.

S30 Command

Action AT+s30<timer>

Query AT+s30?

Range

Parameter

Values:

AT+s30=?

0-255 = Seconds

0 = Default value

RFM-4002-5015 Rev 3 85

iR1200 Modem

86 nextel.com

S-Registers

S-Registers

In this chapter, you are will learn about S-registers and how to configure registers for your iR1200 modem.

This chapter includes:

S-Register

Programming S-Register

Reading S-Register

Supported S-Register

Page 87

Page 87

Page 88

Page 88

S-Registers

S-registers are memory locations in the modem that you can program to meet your communication needs. S-register parameters are numbered from 0 (zero) to 255. Since many of the registers are reserved for internal operation purposes, you are allowed to customize only a subset of the modem’s register.

Programming the S-Register

The following table describes the steps to program an S-Register.

1 From the command mode of your communication software, type ATSn=x where n is the number of the S-register you wish to customize and x is the value that you wish to assign to that register.

2 Press ENTER to execute the command.

!

You may experience undesirable consequences if you modify the S7 or S10 registers from their set default values. For optimal performance, it is recommended that you use the default values set for these two registers.

RFM-4002-5015 Rev 3 87

iR1200 Modem

!

If you write to an S-register that is not programmable or if the value you assigned is invalid, the modem will still return an OK message to the computer screen. The attempted changes will not affect the S-register values.

.

Reading an S-Register Value

The following table describes how to read a value for an S-Register.

1 From the command mode, type ATSn (n= the number of the S-register that you want to read) and press ENTER.

2 The value of the requested S-register displays.

NOTE: If you attempt to read the value of an S-register that is not supported, the modem will display an ERROR message.

Supported S-Registers

The following table outlines the list of S-Registers that can be used to customize your modem.

Register #

0

Function

Automatic Answer. Determines if the modem automatically answers incoming calls.

• If the value assigned to this register is 0 (zero), the modem does not answer the call but sends an appropriate message to the computer that commands the modem to answer the call.

• If the value assigned to this register is a nonzero, the modem answers the call without waiting for the computer to issue its answer-call command.

88 nextel.com

S-Registers

Register #

2

3

4

5

6

7

Function

Valid value ranges from 0 (zero) to 255. 0 (zero) is the default value.

Escape (ESC) Code Character. Specifies the ASCII character to be used to escape from either data or online mode to command mode.

Valid value ranges from 0 (zero) to 127. 43 or the

ASCII plus (+) key is the default value.

Command Line Terminating Character. Specifies the ASCII character to be used to terminate a command line without carrying out any command that might be issued.

Valid value ranges from 0 (zero) to 127. 13 (which represents the ENTER (PC Compatible) or

RETURN (Macintosh) key) is the default value.

Response Format Character.

Valid value ranges from 0 (zero) to 127. 10 is the default value.

Command Line Editing Character.

Valid value ranges from 0 (zero) to 127. 8

(representing the Backspace key) is the default value.

Pause Before Blind Dialing.

Valid value ranges from 2 to 10. 2 (seconds) is the default value.

Connection Completion Timeout.

Valid value ranges from 0 (zero) to 255 seconds.

120 (seconds) is the default value.

RFM-4002-5015 Rev 3 89

iR1200 Modem

Register #

8

10

12

30

Function

Command Dial Modifier Time.

Valid value ranges from 0 (zero) to 255 seconds. 2

(seconds) is the default value.

Automatic Disconnect Delay. Determines the amount of time between loss of carrier and disconnection of the data call.

Valid value ranges from 1 to 254 tenths of a second.

14 (1.4 seconds) is the default value.

Escape Code Timer. Determines the time duration within which the escape code must be sent by the computer to escape from online command mode.

The time (in seconds) the modem waits is determined by dividing the specific register value by 50.

Valid value ranges from 20 to 255. 50 or 1 second

(50/50) is the default value.

Idle Timeout. Determines the amount of time that the modem waits in online mode for a command from the computer before disconnecting the call and returning to command mode.

Valid value ranges from 0 (zero) to 255 seconds. 0

(infinite time period) is the default value.

90 nextel.com

Troubleshooting

Troubleshooting

This chapter describes typical configuration problems and provides instructions on how to troubleshoot issues with the iR1200 modem.

This chapter includes:

Common Problems

Error Messages

Diagnostic Commands

Extended AT Command

Extended Error Result Codes

Page 91

Page 93

Page 94

Page 95

Page 95

Common Problems

The following table identifies the most common problems that may occur while setting up and using your modem for data calls.

!

IMPORTANT INFORMATION: Customers cannot ping a

Non Routable IP address when provisioned due to the

NAT (Network Address Translator) Server. This server attaches a Class C Public IP Address to a Private

Class A Non Routable IP address for a specific period of time to browse the public internet. This Class C address is needed in order to route on the public internet, as Non-Routable IPs are for internal routing only (Intranet).

Symptom

The modem does not respond to AT commands.

Troubleshooting Tips

Make sure that:

• The modem is powered on.

• The cable is properly connected to the

RFM-4002-5015 Rev 3 91

iR1200 Modem

Symptom

The NO CARRIER message displays when the modem attempts data calls.

Modem does not autoanswer incoming data calls (not default operation).

Received data is unrecognizable.

Data is being intermittently lost.

Modem seems to respond slower than usual.

92

Troubleshooting Tips modem.

• The cable is connected to the correct port.

• The correct port is specified in your communication software.

• The modem is set to the same baud rate specified in the communication software.

Make sure that the S7 register contains a value greater than or equal to 60 by issuing an AT&V command or by explicitly setting ATS7=’x’ (where x is, enter any number between 1 and 255).

Make sure that the S0 register contains a value other than 0 (zero) by issuing the

AT&V command. You can also explicitly set ATS0=x from the software’s command mode (where x is any number between 1 and 255).

Make sure that the flow control is set to

RTS/CTS (hardware flow control is enabled) in the communication software and is set to &K3.

Make sure that the flow control is set to

RTS/CTS (hardware flow control is enabled) in the communication software and is set to &K3.

Check the signal strength icon to be sure the signal is not weak. nextel.com

Troubleshooting

Symptom

Modem keeps dropping connection.

Modem does not respond to hang-up command from the software’s command mode.

Computer screen appears distorted.

Troubleshooting Tips

Check the signal strength and signal quality icon to be sure the signal is not weak or poor.

Make sure that:

• The Drop DTR on Hang-up is enabled in the communication software.

• The hang-up string setting is

‘+++ATH’.

Turn off Auto Baud by initiating AT+IPR command. Make sure that the baud rate setting in your communication software matches the baud rate setting of the modem.

Turn on Local Echo by initiating the ATE1 command.

No characters are displayed on the computer screen

Images transmitted/received are of poor quality.

Ensure that the RTS/CTS flow control is enabled in the communication software and is set to &K3.

Error Messages

The following table outlines error messages that you may receive when sending or receiving data. These error messages will appear on the computer screen

Message

ERROR

Explanation

• The command was not recognized.

• The command line maximum length was exceeded.

RFM-4002-5015 Rev 3 93

iR1200 Modem

BUSY

Message

MODEM

INITIALIZATION

FAILED

NO CARRIER

Explanation

• An invalid parameter was entered.

The command line is ready for another command. Make sure that the command

(and parameter) that you entered are valid.

The number you called is busy. You should try the call again later. The modem is ready to accept another command.

Your communication software assumes that

Auto Baud is supported by the modem.

Make sure that:

• That the baud rate = 19200 bps.

• If Auto Baud is turned on in the software, it must be turned on in the programming menu of your modem.

Your connection was terminated, or an attempt to establish the connection failed.

Try your call again and contact your iDEN carrier.

Diagnostic Commands

If a data connection could not be established, you might be able to determine the cause through the AT command interface.

The following steps describe how to obtain modem or system information that will help you with configuration or communication problems.

1 Close all data applications. These applications may start a retry command that will interfere with your troubleshooting efforts.

94

2 Unplug and reconnect the data cable. This will terminate nextel.com

Troubleshooting any ongoing data connections.

3 Establish basic computer to modem communication.

4 Administer the following AT command to query for the last

“Extended Error Code”.

Extended Error AT Command

AT Command Return Product Information

Command Syntax AT+CEER

Expected Return Code(s) See Extended Error Result

Codes Table

Extended Error Result Codes

Extended error result codes report the network reason why a data connection failed. If you report a failed connection to Nextel’s Customer Care, be sure to provide the error result code.

Code General Description

General Modem Operation

257 No further information is available

259 A command was issued during an improper state.

260 User aborted the connection.

261 DCE does not recognize an AT command.

262 Connection was aborted due to connection timeout.

263

266

267

Parameters for an AT Command are out of range.

The +FCLASS command failed due to incompatibilities with the current setting of the +WS46 command.

The +WS45 command failed due to incompatibilities with the value of the +WS46 command.

RFM-4002-5015 Rev 3 95

iR1200 Modem

Code

268

General Description

Invalid DTE-IP address was specified (+WPNEI).

Invalid Home Agent address was specified (+WV305) 269

270

271

272

275

Invalid MIP Security Parameter index was specified.

DCE IP address matched Home Agent IP Address

(+WV304, +WV305).

The DTE tried to lock or unlock the DCE using an incorrect PIN.

An AT Command is not compatible with the current/active data service.

Packet Data Operation

519 Requested level of encryption is not allowed.

545

612

833

835

Service is not present.

A data registration error was found. Contact your service

Provider.

FA: Mobile Node Administrative is prohibited form registration.

FA: Mobile Node Authentication failed.

836

897

899

FA: Home Agent Authentication failed.

HA: Mobile Node Administratively is prohibited from registration.

HA: Mobile Node Authentication failed.

900 HA: Foreign Agent Authentication failed.

1025 SLIP/PPP failed to respond.

1026 SLIP/PP failed to configure the connection.

96 nextel.com

Code

1027

General Description

SLIP/PPP link terminated.

Circuit Data Operation

1280 No information is available.

1290 Unspecified Transmit Phase A Error.

1300 Unspecified Transmit Phase B Error.

1320 Unspecified Transmit Phase C Error.

1330 Unspecified Transmit Phase D Error.

1350 Unspecified Receive Phase B Error.

1360 Unspecified Receive Phase C Error.

1370 Unspecified Receive Phase D Error.

Network Error Codes

1558 No route to specified transit network.

1539 No route to destination.

1553 Called unit is busy.

1563 Destination is out of order.

1564 Invalid number format – incomplete.

1570 No circuit/channel is available.

1574 Network is out of order.

1577 Temporary failure.

1578 Switching equipment congestion.

1580 Requested circuit/channel is not available.

1583 Resource is unavailable.

RFM-4002-5015 Rev 3

Troubleshooting

97

Code

1594

1593

1599

1601

1602

1615

1624 iR1200 Modem

General Description

Bearer capability is not presently available.

Bearer capability is not authorized.

Service or option is not available.

Bearer service is not implemented.

Channel type is not implemented.

Service or option is not implemented

Incompatible destination.

98 nextel.com

Safety Notice

Safety Notice

The following information is important for the safe and efficient operation of the iR1200 modem. Please read this safety notice before operating the modem.

Safe and Efficient Operation Guidelines

Your modem contains a transmitter and receiver. When it is ON, it receives and transmits radio frequency (RF) energy. The modem operates in the frequency range of 806 MHz to 870 MHz and utilizes the digital modulation techniques.

This product is authorized by FCC Rule Part 47CFR2.989 (b) which states that it should be used in such a way that it maintains a distance of at least 8 inches

(20 cms) between the human body and the radio's antenna or modem. When you use your modem, the system handling your call controls the power level at which your modem transmits. The output power level typically varies from 0 mW to 700 mW.

Exposure to Radio Frequency Energy

Your modem is designed to comply with the United States Federal

Communications Commission, Code of Federal Regulations; FCC part 90-sub part S, and FCC-part 15, Class B. The modem complies with FCC’s national standards and guidelines regarding exposure of human beings to radio frequency electromagnetic energy.

Medical and Personal Electronic Devices

Most electronic equipment is protected from RF energy. However, certain equipment may not be shielded against RF signals being emitted from your modem.

Pacemakers

Operators should not use the modem if individuals with pacemakers are within 6 inches (0.15 meters) of the antenna.

RFM-4000-5015 Rev1 99

iR1200 Modem

Hearing Aids

The modem may interfere with hearing aid devices. Individuals who experience such interference should consult the hearing aid manufacturer to discuss alternative solutions.

Other Medical Devices

Individuals who have other medical devices not specifically mentioned in this safety notice may want to consult their physician or the manufacturer of the device to determine if it is adequately protected from external RF energy.

Interference with Other Electronic Devices

RF energy may affect improperly installed or inadequately protected electronic operating and entertainment systems in motor vehicles. Check with the manufacturer or representative to determine if these systems are adequately shielded from external RF energy. It is recommended that you also check with the manufacturer of any equipment that has been added to the vehicle.

100 nextel.com

Copyright and Trademark

Copyright and Trademark

© 2003 Nextel Communications, Inc. Nextel and the Nextel logo are service marks, trademarks and/or registered trademarks owned by Nextel

Communications, Inc. All other product or service names are the property of their respective owners. All trademarks, service marks and trade names are protected by state, federal and/or international trademark laws. All rights reserved.

RFM-4000-5015 Rev1 101

iR1200 Modem

102 nextel.com

Appendix A: Glossary

Appendix A: Glossary

This glossary contains terms and definitions used within this guide. It is by no means exhaustive of terms that you may come across.

ASCII

American Standard Code for Information Interchange. A standard set of 128 characters, symbols and control codes used for computer communications.

ASCII characters require 7 bits of data to send, but are often sent 8 bits at a time with the extra bit being a zero.

Asynchronous Communication

A method of sending data in which the bits can be sent at random times. Data transmission is not synchronized to a clock. With asynchronous transmission, each character is transmitted one at a time with a “start” bit at the beginning and one or more “stop” bits at the end. Any amount of time can elapse before the next character can be sent.

AT Command

An order entered into the computer to request your modem to perform certain actions, such as dial a telemodem number. AT commands are Hayescompatible modem commands.

Baud

The signaling rate of a line, which is the number of transitions (voltage or frequency changes) that are made per second.

Baud Rate

Signaling speed of the modem. Common baud rates are 2400, 4800, 9600,

19200, and 56k.

Byte

A data unit of eight bits.

Circuit Switched Data

A networking technology that provides a temporary, but dedicated, connection between two stations no matter how many switching devices the data is routed

RFM-4000-5015 Rev1 103

iR1200 Modem through. Circuit Switch was originally developed for the analog-based telephone system in order to guarantee steady, consistent service for two people engaged in a phone conversation.

Command Mode

The mode that accepts AT commands. Also known as Terminal Mode. When your modem is in this mode, it is waiting to receive AT commands that you type from your communication software.

Communication Software

A computer program designed to connect your computer to an external source, such as another computer or a fax machine.

Configuration

The term configuration defines the hardware components that comprise a subsystem and system. It is a set of conditions or parameters that define the structure of an item such as the GPS processing and characteristics of the RS-

232 interface ports.

Data Services

One of the functions of your iDEN modem. Data services uses both circuitswitched and packet data transmissions.

DCD

Data Carrier Detect. An acceptable carrier signal received by the modem over the modem line. Also known as Received Line Signal Indicator (RLSI).

DCE

Data Communication Equipment. The equipment that establishes, maintains, and terminates a connection. It converts data into units of sound and vice versa for communication over telemodem or cellular networks.

Default

A factory preset choice that, under normal circumstances, works best for your system. You can either accept the default or change it.

Differential Capable

A term used to describe a GPS receiver capable of receiving and applying differential GPS corrections.

104 nextel.com

Appendix A: Glossary

Differential GPS

A procedure of correcting GPS solutions to achieve improved position accuracy. Differential GPS provides 2 to 5 meter position accuracy. Differential accuracy is obtained by applying corrections determined by the stationary

Differential Reference Station to the GPS data collected by the RPU (receiver processing unit) on-board the vehicle.

DNS

Domain Name Server. This is what converts names of domains (ex. : www.nextel.com) into IP addresses (ex. : 170.206.225.22). The DNS server that you use is generally situated with your access provider.

DTE

Data Terminal Equipment. A computer or hand-held device that generates and receives data, and provides functions that control data communications through a device like the modem.

Dial Up Networking (DUN)

A component in Windows that enables you to connect your computer to a network via modem. If your computer is not connected to a LAN and you want to connect to the Internet, you need to configure Dial-Up-Networking (DUN) to dial a Point of Presence (POP) and log into your Internet Service Provider

(ISP). Your ISP will need to provide certain information, such as the gateway address and your computer’s IP address.

Firmware

A set of software computer/processor instructions permanently or semipermanently resident in read-only memory.

Frequency

The number of vibrations per second of an audio or radio signal. Measured in hertz (Hz), Kilohertz (kHz), or megahertz (MHz). GPS frequencies are L1=

1575.42 MHz or L2= 1227.60 MHz.

GPS

( Global Positioning System) is a "constellation" of 24 well-spaced satellites that orbit the Earth and make it possible for people with ground receivers to pinpoint their geographic location. The location accuracy is anywhere from 100 to 10 meters for most equipment. Accuracy can be pinpointed to within one (1) meter with special military-approved equipment. The GPS is owned and

RFM-4000-5015 Rev1 105

iR1200 Modem operated by the U.S. Department of Defense but is available for general use around the world.

GPS Antenna

An antenna designed to receive GPS radio navigation signals.

GPS Processor

An electronic device that interprets the GPS radio navigation signals (received by the GPS antenna) and determines a location solution. The GPS processor may also be able to apply (and determine) differential GPs corrections.

GPS Receiver

The combination of GPS antenna and GPS processor.

Hand-Held Devices

Small computing appliances, such as palmtops, personal digital assistants and pen-based computers.

Hertz (Hz)

A frequency unit equal to one cycle per second.

Home Agent

The carrier or router responsible for determining the next network point to which a packet (data) should be forwarded toward its destination.

Internet

A series of interconnected local, regional, national and international networks, linked using TCP/IP. The Internet links many government, university, research and commercial sites. It provides e-mail, Web browsing and file transfer services.

Internet Service Provider (ISP)

Provides your computer with Internet access. Also known as Service Provider.

Intranet

A network based on TCP/IP protocols (an internet) belonging to an organization, usually a corporation, accessible only by the organization’s members, employees or others with authorization. An Intranet’s Web sites look and act just like any other Web sites, but the firewall surrounding an intranet fends off unauthorized access.

106 nextel.com

Appendix A: Glossary

Kbps

Kilobits per second. Generally represented at 1000 bits per second.

Laptops

Portable computers, such as notebooks and sub-notebooks.

Local Area Network (LAN)

A computer network that spans over a relatively small area. Most LANs are confined to a single building or group of buildings.

Mobile IP

An IP enhancement that provides forwarding of traffic to moving users. It uses agents in the user’s home network and in all foreign networks. When logging on to a remote network, users register their presence with the foreign agent, and the home agent forwards the packets to the remote network. Mobile IP permits mobile devices to inform a “visited” network that it is present and then arrange to have its home network forward data to it automatically.

Modem

An electronic device enabling digital data to be sent over analog transmission facilities. Converts a digital signal to analog and back to digital again. Modem stands for Modulator/De-Modulator.

NMEA

National Marine Electronics Association. An association that defines marine electronic interface standards for the purpose of serving the public interest.

Non-Routable IP

A communications protocol that contains only a device address and not a network address. It does not incorporate an addressing scheme for sending data from one network to another. Examples of non-routable protocols are NetBIOS and DEC’s LAT protocols. Also some TCP’IP addresses are considered nonroutable.

Non-Volatile Memory

Memory that holds its content without power. Permanently stored information that is not lost when you power off. ROMs, PROMs, EPROMs and flash memory are examples.

RFM-4000-5015 Rev1 107

iR1200 Modem

Packet of Data

A bundle or block of data, organized in a specific way for transmission.

Parallel Port

A low speed port, usually located on the rear of a computer which usually connects to printers. Parallel ports transmit data simultaneously over eight

“parallel wires” one byte at a time (as opposed to a serial port, which transmits data one bit at a time).

Parity Bit

Parity is a process for detecting whether bits of data have been altered during transmission. A Parity Bit is a non-data bit that is added to a group of data bits to check for transmission errors. Parity Bits are used in Parity checking which is an error-checking method in asynchronous transmission. The parity bit tells the receiving end of a transmission whether there should be an even or odd number of bits contained in that transmission.

PIN

Personal Identification Number.

PING

(Packet INternet Groper) An Internet utility used to determine whether a particular IP address is online. It is used to test and debug a network by sending out a packet and waiting for a response. A program used to test whether or not a network component is available.

PPP

(Point-to-Point Protocol) The most common method for connecting to the

Internet. PPP provides serial line (dial-up) connectivity, authentication, compression and encryption between two computers and can handle several protocols simultaneously.

Protocol

Hardware and software standards that govern transmission between two communications devices. There are several layers, or levels, of functionality in a protocol. Each layer may be available, as a separate software component, or several layers may be combined into one.

Public IP Address

See Routable IP Address.

108 nextel.com

Appendix A: Glossary

RAM

Random Access Memory is the working memory of the computer where you can enter information and call up data.

Routable IP Address (Public IP Address)

A communications protocol that contains a network address as well as a device address, allowing data to be routed from one network to another. Examples of routable protocols are SNA, OSI, TCP/IP, XNS, IPX, AppleTalk and DECnet.

RS-232

A communication standard for digital data. Specifies a number of signal and control lines. RS-232 is often associated with a 25-pin connector called DB-25.

Serial Port

An input/output (I/O) port transmits data one bit at a time, as opposed to a parallel port that transmits multiple (usually eight) bits simultaneously.

RS232C is a common serial interface standard.

Service Specific Software

A program designed for a designated online service such as AOL.

Start Bit

A data bit used in asynchronous transmission to signal the beginning of the character.

Stop Bit

A data bit used in asynchronous transmission to signal the end of the character.

System Administrator

The person responsible for monitoring computer activity in a specified area, such as a company.

Synchronous Communication

A method of sending digital data in which the bits come at fixed, rather than random, times and are synchronized to a clock.

TCP/IP (Transmission Control Protocol/Internet Protocol)

The two best-know Internet protocols, often erroneously thought of as one protocol. TCP enables two hosts to establish a connection and exchange streams of data. TCP guarantees delivery of data and guarantees that packets

RFM-4000-5015 Rev1 109

iR1200 Modem will be delivered in the same order in which they were sent. IP acts as a postal system, allowing you to address a package and drop it in the system, but doesn’t provide a direct link between you and the recipient. TCP/IP, on the other hand, establishes a connection between two hosts so that they can send messages back and forth for a period of time.

Terminal Mode

The mode that accepts AT commands. Also known as Command Mode. When your modem is in this mode, it is waiting to receive AT commands that you type from your communications software.

Transmission Rate

The rate at which data is transferred measured in bits per second. Common transfer rates are 9.6bps / 19200bps / 57600bps / 115200bps

UTC

Universal Time Coordinated. Uniform atomic time system/standard that is maintained by the US Naval Observatory. UTC defines the local solar mean time at the Greenwich Meridian.

UTC Offset

The difference between local time and UTC (Example: UTC – EST = 5 hours).

110 nextel.com

Index

A

AC Power Adapter · 3

B

Bits · 29

C

Circuit data · 8

COM1 · 29

Coverage · 5

CTS · 15

Customer Care · 5, 6

D

Data bits · 29 data packet applet · 18

DB-9-P · 14

DB-9-S · 14

DCD · 2, 3, 27, 31, 44, 45, 78

DCE · 3, 14, 30, 37, 39, 40, 41, 48,

49, 50, 51, 52, 53, 56, 58, 65,

66, 78

DSR · 15

RFM-4000-5015 Rev1

Index

DTE · 4, 14, 15, 30, 34, 37, 39, 40,

41, 48, 49, 53, 54, 55, 56, 57,

58, 65, 66, 79

DTR · 2, 3, 15, 27, 30, 45, 62

E

Electronic Devices · 73

Encryption · 54

F

Flow control · 29

G

GPS · 3, 5, 7

GPS-Enabled Modem · 8

H

Hearing Aids · 74

HyperTerminal · 28

I iDEN · 7 images · 35, 44

111

iR1200 Modem

IMEI · 6

Installation Guide · 3

L

LED indicators · 15

M mobile IP · 32

Mobile IP · 2, 4, 27, 32, 33, 51,

52, 81

P

Pacemakers · 73

Packet Data · 8

Packet StreamGold · 18

Parity · 29

PIN · 3, 33, 49, 50, 66, 82

PPP · 2, 27, 31, 32, 34, 51, 55, 67,

82 processor · 17 profile · 35, 38, 47

Q

Quick Reference Guide · 3

R

Radio Frequency · 73

RAM · 17 required components · 3

RS-232 · 13

RTS · 15

Rugged Modem · 8

Rx · 15

S

SIM ID · 6

SLIP · 2, 3, 27, 31, 32, 51, 55, 67

Stationary Environment · 14

Stop bits · 29

T

TCP/IP Protocol · 23

Tx · 15

V

Vehicle Power Harness · 3

112 nextel.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents