Pelco Switch FR82041 User's Manual


Add to my manuals
28 Pages

advertisement

Pelco Switch FR82041 User's Manual | Manualzz
I N S T A L L A T I O N
®
FT82041/FR82041
Unmanaged
Ethernet Switch
Four 10BASE-T/100BASE-TX Ports and
One 100BASE-FX Fiber Port
C2623M (2/07)
Contents
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting 10BASE-T/100BASE-TX Port Modes of Operation. . . . . . . . . . . . . . . . . . . . . . .
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting the FT82041/FR82041 Module into a Rack . . . . . . . . . . . . . . . . . . . . .
Mounting the FT82041/FR82041 Module to a Wall . . . . . . . . . . . . . . . . . . . . . . .
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
11
13
13
13
15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Appendix. RJ-45 Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
List of Illustrations
1
2
3
4
5
6
7
FT82041 and FR82041 Point-to-Point Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Front Panel of FT82041 and FR82041 Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Rear Panel of FT82041 and FR82041 Modules (SC Fiber Connector Shown) . . . . . . . . . 10
TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-4 . . . . . . . . . . . . . . . . . . . . . . . 11
Mounting the FT82041/FR82041 Module Using the Wall Clip . . . . . . . . . . . . . . . . . . . . 14
FT82041/FR82041 Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RJ-45 MDI/MDI-X Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
List of Tables
A
B
C
D
C2623M (2/07)
TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting with Front-Panel Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting with Rear-Panel Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RJ-45 MDI/MDI-X Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
17
19
26
3
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold
with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Use only installation methods and materials capable of supporting four times the maximum
specified load.
18. A CCC-approved power cord must be used to power this equipment when used in China.
19. CAUTION: These servicing instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that contained in
the operating instructions unless you are qualified to do so.
4
C2623M (2/07)
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
C2623M (2/07)
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
5
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this
equipment can void your authority to operate this equipment under Federal Communications
Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
6
C2623M (2/07)
Product Overview
DESCRIPTION
The FT82041/FR82041 unmanaged Ethernet switch provides four 10BASE-T/100BASE-TX ports and one
100BASE-FX fiber port for the transport of bidirectional Ethernet data. Designed for point-to-point
applications, the FT82041 and FR82041 switches are used in combination with one another to provide
wavelength compatibility (refer to Figure 1).
FOUR 10/100 Mbps
CONNECTIONS
FOUR 10/100 Mbps
CONNECTIONS
FT82041
FR82041
ONE
FIBER
Figure 1. FT82041 and FR82041 Point-to-Point Application
Features of the FT82041/FR82041 Ethernet data transmission system include the following:
•
User-selectable networking functions for each 10BASE-T/100BASE-TX port:
–
Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex
and half-duplex modes
–
10 Mbps or 100 Mbps selectable
–
Full-duplex or half-duplex mode selectable
–
Enabling/disabling of flow control
NOTE: The 100BASE-FX fiber port is automatically forced to full-duplex 100 Mbps operation.
•
Auto MDI/MDI-X (Medium Dependent Interface/Medium Dependent Interface Crossover)
operation
•
Compliant with IEEE 802.3, 802.3u, 802.3x standards
•
Multimode fiber support for distances up to 2 km
•
Single-mode fiber support for distances up to 46 km
•
Integrated wavelength division multiplexing (WDM), which allows bidirectional data to be
transmitted in a single fiber
•
Laser diode for transmission of optical signals
NOTE: The FT82041/FR82041 switch is a Class 1 laser product that complies with FDA
radiation performance standard 21CFR Subchapter J and with IEC 60825-1 Edition 1.2, 2001-08.
•
•
Compatible with other Ethernet equipment:
–
10BASE-T/100BASE-TX compatibility with all Pelco© and third-party 10BASE-T/
100BASE-TX Ethernet devices
–
Fiber optic compatibility with all Pelco Ethernet devices that support WDM
Environmentally hardened
C2623M (2/07)
7
•
Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for
ambient operating temperature, mechanical shock and vibration, humidity with condensation,
high-line/low-line voltage conditions, and transient voltage protection
NOTE: Conformal coating is required for operation in environments with relative humidity
above 95 percent (condensing).
•
No performance adjustments required
•
12 VDC or 24 VAC power supply
•
Stand-alone and rack-mountable modular design
•
LED indicators for monitoring of optic signal/laser status, 100BASE-FX port status including far
end fault indication (FEFI), 10BASE-T/100BASE-TX port status, and operating power
MODELS
The FT82041 and FR82041 modules consist of the following series of models:
Multimode Models*
FT82041MSTR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
ST fiber port, one fiber, fiber optic compatibity with FR82041MSTR-1 and other
multimode ST Pelco Ethernet devices that support WDM
FR82041MSTR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
ST fiber port, one fiber, fiber optic compatibility with FT82041MSTR-1 and other
multimode ST Pelco Ethernet devices that support WDM
FT82041MSCR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
SC fiber port, one fiber, fiber optic compatibility with FR82041MSCR-1 and other
multimode SC Pelco Ethernet devices that support WDM
FR82041MSCR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
SC fiber port, one fiber, fiber optic compatibility with FT82041MSCR-1 and other
multimode SC Pelco Ethernet devices that support WDM
Single-Mode Models*†
FT82041SSTR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one singlemode ST fiber port, one fiber, fiber optic compatibility with FT82041MSCR-1 and
other single-mode ST Pelco Ethernet devices that support WDM
FR82041SSTR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one singlemode ST fiber port, one fiber, fiber optic compatibility with FT82041SSTR-1 and
other single-mode ST Pelco Ethernet devices that support WDM
FT82041SSCR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one singlemode SC fiber port, one fiber, fiber optic compatibility with FR82041SSCR-1 and
other single-mode SC Pelco Ethernet devices that support WDM
FR82041SSCR-1
Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one singlemode SC fiber port, one fiber, fiber optic compatibility with FT82041SSCR-1 and
other single-mode SC Pelco Ethernet devices that support WDM
*
For conformal coated models, replace the first letter F in the model number with the letter C.
The conformal coated version of FT82041MSTR-1, for example, is CT82041MSTR-1.
†
Single-mode FC connector is available upon request. Contact the factory for additional information.
8
C2623M (2/07)
OPTIONAL ACCESSORIES
The following optional accessories are available:
WM5001-3U
WM5001-3UEXP
RK5000-3U
RK5000PS-3U
EPS5000-120
RK5001B-3U
RK5002B-3U
RK5001-1UEXP
Wall mount base kit for single-width module
Wall mount expansion kit for single-width module
19-inch rack mount chassis for 14 slots (no power), 3 RUs
19-inch rack mount chassis for 12 slots with power, 3 RUs
External rack power supply, 1 RU, dual 120 W power outputs
Blank filler panel, single width
Blank filler panel, double width
Adapter kit that allows a 3 RU single-width fiber module to be used in
RK5000PS-5U rack mount chassis
FRONT PANEL
Figure 2 illustrates the front panel of the FT82041 and FR82041 modules.
FT82041
FR82041
Figure 2. Front Panel of FT82041 and FR82041 Modules
ì Reset Button: Restarts the unit
î 100BASE-FX Status LED
ï Optic Fault LED: Optical signal status/laser status indicator
ñ Power LED: Pelco badge
For detailed information about the front-panel LEDs, refer to Troubleshooting on page 17.
C2623M (2/07)
9
REAR PANEL
Figure 3 illustrates the rear panel of the FT82041 and FR82041 modules.
FT82041
FR82041
Figure 3. Rear Panel of FT82041 and FR82041 Modules (SC Fiber Connector Shown)
ì Rack Power/Alarm Connector: 4-pin connector for power/alarm connection of rackmounted module
î Stand-Alone Power Connector: 2-pin connector for power connection of stand-alone
module; removable mating connector with screw terminals (not shown)
ï 10BASE-T/100BASE-TX Ports 1-4: RJ-45 connectors
ñ Fiber Optic Port: Single-fiber ST or SC connector (dependent on FT82041/FR82041 model);
port A on FT82041 module and port B on FR82041 module
ó RJ-45 10BASE-T/100BASE-TX Port Status LED, Left: Link/activity status indicator
r RJ-45 10BASE-T/100BASE-TX Port Status LED, Right: Duplex mode/collision indicator
For additional information about rear-panel connections, refer to Installation on page 11. For detailed
information about the RJ-45 LEDs, refer to Troubleshooting on page 17.
10
C2623M (2/07)
Installation
PACKAGE CONTENTS
The following items are supplied:
1
FT82041 or FR82041 module
1
Regulated switching power supply with four plug adapters (North American, Australian, U.K.,
and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output
1
Wall clip with two 4-40 x 0.250-inch Phillips pan head screws with lock washers (for attachment
of single module to wall)
1
FT82041/FR82041 Fiber Transmitter and Receiver Installation manual
SETTING 10BASE-T/100BASE-TX PORT MODES OF OPERATION
NOTE: As a matter of convenience, it is recommended that you verify the modes of operation for
each 10BASE-T/100-BASE-TX port and then change the mode settings—if necessary—before
mounting the FT82041/FR82041 module into a rack or onto a wall.
The FT82041/FR82041 module provides various configuration options that allow you to select the
desired modes of operation for each 10BASE-T/100BASE-TX port (ports 1-4). You can select the
desired modes of operation by means of a TX Mode switch that is provided on the bottom of the
module for each port (refer to Figure 4).
TX MODE SWITCHES - PORTS 1-4
TX Mode
Left L
LINK
Righ
DUPL
Figure 4. TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-4
C2623M (2/07)
11
Using the TX Mode switch for a particular port, you can do the following:
•
Enable autonegotiation or select (force) a specific data rate and duplex mode:
–
Enabling autonegotiation allows the FT82041/FR82041 module to automatically
negotiate with the device to which the port is connected for data rate and duplex modes
of operation: 10 Mbps or 100 Mbps data rate and half-duplex or full-duplex mode. The
highest common denominator of operational modes is automatically selected.
Autonegotiation is enabled by default.
–
If autonegotiation is not desired, you can select a specific data rate and duplex mode:
•
•
•
Data rate configuration allows you to select 10 Mbps or 100 Mbps.
Duplex mode configuration allows you to select half-duplex mode or full-duplex
mode.
Enable or disable flow control. Flow control controls data transmission at the sending device
to avoid overfilling buffers and losing data at the receiving device. When the buffers on the
receiving device are full, a message is sent to the sending device to suspend the transmission
until the data in the buffers has been processed.
NOTE: For time-sensitive data applications (for example, video and audio applications), it is
recommended that flow control be disabled.
Flow control is disabled by default.
With the FT82041/FR82041 module powered off, set each TX Mode switch to the desired 10BASE-T/
100BASE-TX port modes of operation. Refer to Table A for TX Mode switch settings and
corresponding modes of operation. Note that each 10BASE-T/100BASE-TX port operates
independently of one another; therefore, each port can be set to different modes of operation as
appropriate.
Table A. TX Mode Switch Settings
TX Mode
Switch Position
10BASE-T/100BASE-TX Modes of Operation
0
Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and
100 Mbps and between half-duplex and full-duplex modes, disables
flow control (default setting)
1
100 FD/Dis FC: Selects 100 Mbps full-duplex, disables flow control
2
100 HD/DIS FC: Selects 100 Mbps half-duplex, disables flow control
3
10 FD/Dis FC: Selects 10 Mbps full-duplex, disables flow control
4
10 HD/Dis FC: Selects 10 Mbps half-duplex, disables flow control
5
Auto Neg/En FC: Enables autonegotiation between 10 and 100 Mbps
and between half-duplex and full-duplex modes, enables flow control
6
100 FD/En FC: Selects 100 Mbps full-duplex, enables flow control
7
100 HD/En FC: Selects 100 Mbps half-duplex, enables flow control
8
10 FD/En FC: Selects 10 Mbps full-duplex, enables flow control
9
10 HD/En FC: Selects 10 Mbps half-duplex, enables flow control
NOTE: Switch positions 0-4 disable flow control. Positions 5-9 enable flow control.
12
C2623M (2/07)
NOTE: TX Mode configuration must be set when the module is powered off. If you wish to change
a TX Mode switch setting after the module has been powered on, power off the module, change the
TX Mode switch setting, and then power on the module again.
MOUNTING
The FT82041/FR82041 module can be mounted into a rack or can be used as a stand-alone module.
As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall.
NOTE: As a matter of convenience, it is recommended that you set the modes of operation for each
10BASE-T/100-BASE-TX port—if required—before mounting the FT82041/FR82041 module into a
rack or onto a wall. For information about setting the port modes of operation, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on page 11.
MOUNTING THE FT82041/FR82041 MODULE INTO A RACK
The FT82041/FR82041 module can be installed into an RK5000 Series rack mount chassis, which can
be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack
mount chassis includes the following models:
•
RK5000PS-3U and RK5000-3U: Designed to accommodate fiber optic modules as follows:
–
The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a
power supply.
–
The RK5000-3U rack mount chassis provides 14 single-width module slots (a power
supply is not included). Power to the modules can be supplied using the optional
external power supply (EPS5000-120).
For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis
Installation manual.
•
RK5000PS-5U: Designed to accommodate Endura™ modules but can also accommodate fiber
optic modules with the use of the appropriate adapter kit. The RK5001-1UEXP adapter kit is
required for installation of the FT82041/FR82041 module into the RK5000PS-5U chassis.
For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount Chassis
Installation manual.
MOUNTING THE FT82041/FR82041 MODULE TO A WALL
The FT82041/FR82041 module can be mounted to a wall in the following ways:
•
Using the supplied wall clip for attachment of a single module to a wall. For installation
instructions, refer to Mounting the FT82041/FR82041 Module Using the Wall Clip on page 14.
•
Using the optional WM5001 wall mount kits, which are designed for mounting of single-width
fiber optic modules. The WM5001-3U base kit allows mounting of a single module to a wall.
The WM5001-3UEXP expansion kit allows mounting of an additional module. It is
recommended that a maximum of three expansion kits be used with the base kit, allowing a
maximum of four single-width modules to be mounted to a wall.
NOTE: The WM5001 wall mount kits can be used with the WM5002 wall mount kits, which are
designed for mounting of double-width fiber optic modules. If mounting a mix of single-width
and double-width modules is desired, it is recommended that a maximum of two single-width
modules and one double-width module be mounted in combination with one another.
For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount
Kit Installation manual.
C2623M (2/07)
13
Mounting the FT82041/FR82041 Module Using the Wall Clip
NOTE: Before mounting the FT82041/FR82041 module to a wall, ensure that there is adequate space
at both ends for viewing the front-panel LEDs and for making the various rear-panel cable connections.
To attach the FT82041/FR82041 module to a wall using the supplied wall clip, refer to Figure 5 and do
the following:
1. Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall using
two screws (not provided).
2. Slide the module into the clip until the two holes on the bottom of the module align with the
two holes on the lower flange of the clip.
3. Attach the module to the clip using the two Phillips pan head screws provided for the clip.
UPPER
FLANGE
VERTICAL
MOUNTING HOLE (2)
HORIZONTAL
MOUNTING HOLE (2)
SCREW, PHILLIPS
PAN HEAD WITH
LOCK WASHER (2)
WALL CLIP
LOWER
FLANGE
Figure 5. Mounting the FT82041/FR82041 Module Using the Wall Clip
14
C2623M (2/07)
CONNECTIONS
Connections to the FT82041/FR82041 module are made on the rear panel of the unit (refer to Figure 6).
POWER/ALARM CONNECTION
FOR RACK-MOUNTED MODULE
POWER CONNECTION
FOR STAND-ALONE MODULE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
FIBER OPTIC CABLE
Figure 6. FT82041/FR82041 Module Connections
As illustrated in Figure 6, FT82041/FR82041 connections consist of the following:
•
Power connection
NOTES:
•
–
A 12 VDC or 24 VAC power supply can be used to power the module when used as a
stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used,
the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and
rated as 24 VAC, 0.50 A (minimum output).
–
In extreme temperature conditions, it is recommended that an industrial-rated outdoor
power supply such as the Pelco WCS1-4 power supply be used.
10BASE-T/100BASE-TX connections
NOTES:
–
Use Cat5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port.
Cable length must not exceed 328 feet (100 meters).
–
The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a
straight-through or crossover cable can be used. The ports automatically detect the
cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 26 for
pinout information.
C2623M (2/07)
15
•
Fiber connection
NOTE: Fiber port A of the FT82041 module connects to fiber port B of the FR82041 module or
of any other Pelco Ethernet switch that supports wavelength division multiplexing (WDM).
Similarly, fiber port B of the FR82041 module connects to fiber port A of the FT82041 module or
of any other Pelco Ethernet switch that supports WDM. Note that port A and port B provide
wavelength compatibility:
16
–
Multimode fiber port A transmits data at 1310 nm and receives data at 850 nm.
Multimode fiber port B transmits data at 850 nm and receives data at 1310 nm.
–
Single-mode fiber port A transmits data at 1310 nm and receives data at 1550 nm.
Single-mode fiber port B transmits data at 1550 nm and receives data at 1310 nm.
C2623M (2/07)
Troubleshooting
LED indicators on the front and rear panels of the FT82041/FR82041 module allow you to monitor
operational status:
•
LED indicators on the front panel allow you to monitor operating power, 100BASE-FX port
status, and optic signal/laser status. Refer to Table B for information about the front-panel
indicators and associated troubleshooting guidelines.
•
LED indicators on the rear panel allow you to monitor RJ-45 10BASE-T/100BASE-TX port
status. Refer to Table C for information about the rear-panel indicators and associated
troubleshooting guidelines.
Table B. Troubleshooting with Front-Panel Indicators
Indicator Color
Meaning
Possible Cause
Corrective Action
Power LED (Pelco badge)
Blue
Power is being
applied to the
module.
–
No action required.
Not lit
Power is not being
applied to the
module.
Power connection is faulty.
Check power connection.
If module is rack mounted,
reseat module or power
supply as necessary.
Power supply has failed.
Replace power supply.
Loss of power occurs due to Check circuit breakers, fuses,
or electrical service as
tripped circuit breakers,
blown fuses, or faulty elec- necessary.
trical service.
100BASE-FX Status LED (
)
Green
A fiber link is established.
—
No action is required.
Flashing green
—
Data activity is
occurring on the fiber
link.
No action is required.
Red
Far end fault indication (FEFI).
The optical signal
transmitted from this
port is not detected
by the remote link
partner.
Defective fiber transmit port Replace local module.
on local module
Laser fault on local module
(Optic Fault LED on local
module flashes red).
Refer to the Optic Fault LED
section in this table.
Defective fiber receive port
on remote module
Replace remote module.
NOTE: The Optic Fault LED on the remote module is red. Refer to the Optic Fault
LED section in this table for additional information.
(Continued on next page)
C2623M (2/07)
17
Table B. Troubleshooting with Front-Panel Indicators (Continued)
Indicator Color
Meaning
Possible Cause
Optic Fault LED (
Corrective Action
)
Green
The optical signal is
being received and
laser is operating
properly.
—
No action is required.
Red
The optical signal is
not being received.
Remote module is not
powered on.
Check power connections.
Replace power supply if
necessary.
Fiber optic cable is not
connected.
Check fiber optic connections.
Fiber optic cable connectors Clean, polish, or replace fiber
are dirty or are damaged.
optic cable connectors as
necessary.
Fiber optic cable is defective.
Replace cable.
Optical dB losses in the
fiber optic installation
exceed the optical power
budget specification stated
in Specifications on
page 24.
Check for problems with the
fiber optic installation, for
example, excessive dB
losses in connectors, splices,
patch panels, cables,
and so on.
Contact Product Support at
Optical dB losses in the
fiber optic installation meet 1-559-292-1981.
the optical power budget
specification stated in
Specifications on page 24;
however, a module is defective.
Flashing red
Laser has shut down. Module is operating in
extreme environmental
conditions; for example,
operating temperature is
below or above recommended range as stated in
Specifications on page 24.
Laser has reached end of
life.
Ensure that module operates
according to operating
conditions stated in
Specifications on page 24,
and then cycle the power. If
problem persists, contact
Product Support at
1-559-292-1981.
Cycle the power. If problem
persists, contact Product
Support at 1-559-292-1981.
(Continued on next page)
18
C2623M (2/07)
Table C. Troubleshooting with Rear-Panel Indicators
Indicator Color
Meaning
Possible Cause
Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity)
Amber
A 10BASE-T link is
established.
—
If 10BASE-T operation is
desired, no action is required.
If 10BASE-T operation is not
desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
Flashing amber
Data activity is
occurring on the
10BASE-T link; data
is being transmitted
or received.
—
If 10BASE-T operation is
desired, no action is required.
If 10BASE-T operation is not
desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
Green
A 100BASE-TX link
is established.
—
If 100BASE-TX operation is
desired, no action is required.
If 100BASE-TX operation is
not desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
Flashing green
Data activity is
occurring on the
100BASE-TX link;
data is being
transmitted or
received.
—
If 100BASE-TX operation is
desired, no action is required.
If 100BASE-TX operation is
not desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
(Continued on next page)
C2623M (2/07)
19
Table C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color
Meaning
Possible Cause
Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued)
Not lit
A 10BASE-T or
100BASE-TX link
cannot be established.
A problem may exist with
the cable:
• Cable is not connected
to the module or to the
10BASE-T/100BASE-TX
compatible device.
• Cable is defective.
• Cable is not the proper
cable type.
• Cable is not the proper
length.
Do any of the following as
applicable:
• Connect the cable.
• Replace the cable. Use
Cat5e or higher cable.
• Ensure that cable is the
proper length. Cable
length must not exceed
328 feet (100 meters).
Device connected to the
module is not powered on.
Power on the device
connected to the module.
Duplex mode setting (halfduplex or full-duplex) does
not match the duplex mode
setting of the remote
module.
Set the duplex mode setting
on modules to match one
another (autonegotiation or
forced half-duplex or fullduplex). Refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
Port on module is defective. Replace the module.
(Continued on next page)
20
C2623M (2/07)
Table C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color
Meaning
Possible Cause
Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision)
Amber
Port is set to
10BASE-T fullduplex mode.
—
If 10BASE-T full-duplex operation is desired, no action is
required. If 10BASE-T fullduplex operation is not
desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
Flashing amber
Port is set to
10BASE-T halfduplex mode and
network collision
has occurred.*
Normal or excessive
collisions occur on a
half-duplex link.*
If a normal collision occurs, no
action is required.
If a problem with the network
exists due to excessive collisions, do any of the following
as appropriate:
• If half-duplex mode is not
required, set the TX Mode
switch to full-duplex mode
by means of autonegotiation or by forcing the mode
(refer to Setting
10BASE-T/100BASE-TX
Port Modes of Operation
on page 11 for
information).
• If half-duplex mode is
required, do any of the
following as applicable:
– Replace network cable
if it is defective or if it
is not the proper cable
type. Use Cat5e or
higher cable.
– Ensure that cable is the
proper length. Cable
length must not exceed
328 feet (100 meters).
– Replace the network
interface card (NIC) if it
is defective or if it is
incompatible.
– Segment the network.
(Continued on next page)
C2623M (2/07)
21
Table C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color
Meaning
Possible Cause
Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)
Green
Port is set to
100BASE-TX fullduplex mode.
—
If 100BASE-TX full-duplex
operation is desired, no action
is required. If 100BASE-TX
full-duplex operation is not
desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
Flashing green
Port is set to
100BASE-TX halfduplex mode and
network collision
has occurred.*
If a normal collision occurs, no
Normal or excessive collisions occur on a half-duplex action is required.
If a problem with the network
link.*
exists due to excessive collisions, do any of the following
as appropriate:
• If half-duplex mode is not
required, set the TX Mode
switch to full-duplex mode
by means of autonegotiation or by forcing the mode
(refer to Setting
10BASE-T/100BASE-TX
Port Modes of Operation
on page 11 for
information).
• If half-duplex mode is
required, do any of the
following as applicable:
– Replace cable if it is
defective or if it is not
the proper cable type.
Use Cat5e or higher
cable.
– Ensure that cable is the
proper length. Cable
length must not exceed
328 feet (100 meters).
– Replace the network
interface card (NIC) if it
is defective or if it is
incompatible.
– Segment the network.
(Continued on next page)
22
C2623M (2/07)
Table C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color
Meaning
Possible Cause
Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)
Not lit
Port is set to
10BASE-T halfduplex mode and no
collisions are
detected.*
—
If 10BASE-T half-duplex
operation is desired, no action
is required. If 10BASE-T halfduplex operation is not
desired, refer to Setting
10BASE-T/100BASE-TX Port
Modes of Operation on
page 11 for information.
*A collision is a normal event on a half-duplex Ethernet link. A collision occurs when two or more devices,
referred to as stations, attempt to transmit at the same time on a shared physical medium.
Ethernet uses the CSMA/CD (Carrier Sense Multiple Access/Collision Detect) media access method by
which two or more stations share a common transmission medium. Using CSMA/CD, a station monitors
the medium and transmits a message in bit-serial form when it senses that no other station is
transmitting. If, after initiating a transmission, the message collides with that of another station, each
transmitting station then intentionally transmits for an additional predefined period to ensure
propagation of the collision throughout the system. To avoid another collision, each station waits a
random amount of time (backoff) before attempting to transmit again.
Excessive collisions occur when retransmission of a frame fails after 16 consecutive times and the frame
is dropped. Excessive collisions may indicate that the network is becoming congested.
C2623M (2/07)
23
Specifications
PERFORMANCE
Switch Type
Switch Method
Switch Fabric
Data Rate
Compliance
Interface
Operating Mode
Address Table Size
Quality of Service
Maximum Frame Size
GENERAL
Operating Temperature
Input Power Requirements
LED Indicators
Unit Weight
-40° to 167°F (-40° to 75°C)
12 VDC or 24 VAC, 0.50 A
Power
100BASE-FX port status (link/activity, FEFI)
Optic Fault (optic signal/laser status)
10BASE-T/100BASE-TX port status (2 LEDs per port:
link/activity and speed, duplex/collision and speed)
8.75" D x 1.08" W x 4.81" H
(22.23 x 2.74 x 12.22 cm)
1.6 lb (0.73 kg)
MECHANICAL
Connectors
Rack Power/Alarm
Stand-Alone Power
Electrical
Fiber Optic
1, 4-pin connector
1, 2-pin connector, screw terminal
4, RJ-45, 10BASE-T/100BASE-TX
1, single-fiber ST or SC
Dimensions
24
Unmanaged Layer 2
Store and forward
Non-head-of-line blocking
10/100 Mbps
IEEE 802.3, 802.3u, 802.3x
Auto MDI/MDI-X
Full-duplex or half-duplex
1,024 MAC address entries with automatic learning and aging
IEEE 802.1p priority, tag-based, 4 queues per port,
weighted fair queuing scheduling
Untagged Ethernet frames up to 1,518 bytes
Tagged Ethernet frames up to 1,522 bytes
C2623M (2/07)
OPTICAL POWER BUDGET AND MAXIMUM TRANSMISSION DISTANCE
Model Number
Transmitter
End
Receiver
End
Wavelength
(Transmit/Receive)*
Fiber Port A
Optical
Power
Fiber Port B Budget
Maximum
Transmission
Distance
Multimode (62.5/125 μm)
FT82041MSTR-1 FR82041MSTR-1 1310/850 nm
850/1310 nm
26 dB†
2 km (1.2 mi)‡
FT82041MSCR-1 FR82041MSCR-1 1310/850 nm
850/1310 nm
26 dB†
2 km (1.2 mi)‡
Single-Mode (9/125 μm)
FT82041SSTR-1
FR82041SSTR-1
1310/1550 nm 1550/1310 nm
28 dB
46 km (28.6 mi)§
FT82041SSCR-1
FR82041SSCR-1
1310/1550 nm 1550/1310 nm
28 dB
46 km (28.6 mi)§
* The FT82041 and FR82041 modules are classified by the FDA as Class 1 laser products. For 850 nm,
the Class 1 laser limit is <0.78 mW. For 1310 nm, the Class 1 laser limit is <15.6 mW. For 1550 nm,
the Class 1 laser limit is <10.0 mW.
†
When using 50/125 μm multimode fiber, subtract 3 dB from the optical power budget.
‡
Maximum transmission distance is limited by fiber bandwidth.
§
Maximum transmission distance is based on attenuation of 0.5 dB/km plus a 5 dB buffer for
connector and splice losses.
NOTES:
•
Single-mode FC connector is available upon request. Contact the factory for additional
information.
•
For conformal coated models, replace the first letter F in the model number with the letter C.
The conformal coated version of FT82041MSTR-1, for example, is CT82041MSTR-1.
•
For models with higher optical power budgets, contact the factory.
C2623M (2/07)
25
Appendix. RJ-45 Connector Pinouts
Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts.
MDI (NORMAL MODE)
MDI-X (CROSSED MODE)
8
8
7
TX-
7
RX-
6
4
4
TX+
RXRX+
6
5
5
RX+
TXTX+
3
2
1
3
2
1
Figure 7. RJ-45 MDI/MDI-X Connector Pinouts
Table D summarizes RJ-45 MDI/MDI-X connector pinouts.
Table D. RJ-45 MDI/MDI-X Connector Pinouts
Pin Number
MDI
(Normal Mode)
MDI-X
(Crossed Mode)
1
RX+
TX+
2
RX-
TX-
3
TX+
RX+
4
Not used
Not used
5
Not used
Not used
6
TX-
RX-
7
Not used
Not used
8
Not used
Not used
The materials used in the manufacture of this document and its components are compliant to the
requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste
electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling
this equipment.
26
C2623M (2/07)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
• Five years on fiber optic products and TW3000 Series unshielded twisted pair transmission products.
• Three years on Spectra® IV products.
• Three years on Genex® Series products (multiplexers, server, and keyboard).
• Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H2X camera models, which have a five-year warranty.
• Three years on PMCL200/300/400 Series LCD monitors.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
• Two years on Spectra III™, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
• Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).
• Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays. The lamp and color wheel will be covered for a period of
90 days. The air filter is not covered under warranty.
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura™ Series distributed network-based video
products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this
warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
Date
C2623M-BETA 10/06
C2623M
2/07
Comments
Beta version.
Official release.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura, ExSite, and Spectra III are trademarks of Pelco.
DLP is a registered trademark of Texas Instruments, Inc.
©Copyright 2007, Pelco.
All rights reserved.
®
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
www.pelco.com
ISO9001
Australia
| Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore
| Spain | Sweden | United Arab Emirates | United Kingdom | United States
South Africa

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement