Gas Inserts
Model
Fuel Type
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifi ce Size -Altitude 0-4500 ft.
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
E33-NG1
Natural Gas
5” W.C. (1.25 kPa)
3.8” W.C. (0.95 kPa)
1.1” W.C. (0.27 kPa)
#31 DMS
20,000 BTU/h
(5.86 kW)
38,000 BTU/h
(11.14 kW)
3” Co-linear
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
E33 Gas Insert
E33-LP1
Propane
12” W.C. (2.99 kPa)
11” W.C. (2.74 kPa)
2.9” W.C. (0.72 kPa)
#50 DMS
19,000 BTU/h
(5.57 kW)
35,500 BTU/h
(10.40 kW)
3” Co-linear
A
E33 Gas Insert
B
D H
30°
C
F
G
E
Dimension Description
G
H
E
F
A
B
C
D
I
Faceplate Width
Faceplate Height
Unit Width
Unit Height
Unit Depth
Faceplate to Vent Centerline
Faceplate Depth
Height to Vent Collar
Optional or Standard Front Depth
June 2007 Regency Product Specifi cations Book
E33
45-9/16” (1157mm)
31-1/8” (791mm)
32-1/4” (819mm)
23-13/16” (605mm)
16-3/4” (426mm)
11-1/4” (286mm)
1-3/8” (35mm)
23” (583mm)
N/A
Minimum Fireplace Dimensions
The minimum fi replace dimensions for the FPI gas fi replace insert are shown in the following diagrams:
J aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa
M
L aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa
Dimension Description
L
M
J
K
N
Height
Width
Depth
Max. Lintel Bar Depth
Rear Width aaaaaaaaaa aaaaaaaaaa
K aaaaaaaaaa aaaaaaaaaa aaaaaaaaaa
N
Contour Faceplate
24-3/16” (614mm)
32-1/4” (819mm)
17” (432mm)
8” (203mm)
25” (635mm)
127
Gas Inserts
E33 Gas Insert
Clearances
Unless otherwise stated the clearances listed below are Minimum distances to combustible materials. Please Note: A major cause of chimney related fi res is due to a failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
Combustible Mantels
Because of the extreme heat this fi replace emits, the mantel
clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher.
Clearances to Combustibles
Dimension Description E33
D
E
F
A*
B
C
From Unit to Side Walls
From Unit to Ceiling
Minimum Mantel Height
Maximum Mantel Depth
Alcove Width
Alcove Depth
8” (203mm)
47” (1194mm)
15” (381mm)
12” (305mm)
76” (1930mm)
36” (914mm)
G
H
Hearth Height
Hearth Width
1-¼” (32mm)
45-½” (1156mm)
I Hearth Depth 13” (330mm)
* Alcove side wall must have a minimum of 8” (203mm) clearance on one side.
128
D
Flush Front Mantel Clearances
12 10 8 6 4 2
0
20
12" (305mm) Mantel
18
16
47”
(1194mm) to ceiling
14
12
10
8
6
4
2
3-1/2" (89mm) Mantel
20”
(508mm)
15”
(381mm)
0
Top of
Unit
25" (635mm) to floor
Side View
Full Screen Door Mantel Clearances
Note: A non-combustible mantel may be installed at a lower height.
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
June 2007 Regency Product Specifi cations Book