Regency E33-NG1 User's Manual


Add to my manuals
2 Pages

advertisement

Regency E33-NG1 User's Manual | Manualzz

Gas Inserts

Model

Fuel Type

Minimum Supply Pressure

Manifold Pressure - High

Manifold Pressure - Low

Orifi ce Size -Altitude 0-4500 ft.

Minimum Input

Altitude 0-4500 ft. (0-1372m)

Maximum Input

Altitude 0-4500 ft. (0-1372m)

Vent Sizing

E33-NG1

Natural Gas

5” W.C. (1.25 kPa)

3.8” W.C. (0.95 kPa)

1.1” W.C. (0.27 kPa)

#31 DMS

20,000 BTU/h

(5.86 kW)

38,000 BTU/h

(11.14 kW)

3” Co-linear

Approved Venting Systems

Flex Vent Systems: FPI AstroCap™ Flex Vent

E33 Gas Insert

E33-LP1

Propane

12” W.C. (2.99 kPa)

11” W.C. (2.74 kPa)

2.9” W.C. (0.72 kPa)

#50 DMS

19,000 BTU/h

(5.57 kW)

35,500 BTU/h

(10.40 kW)

3” Co-linear

A

E33 Gas Insert

B

D H

30°

C

F

G

E

Dimension Description

G

H

E

F

A

B

C

D

I

Faceplate Width

Faceplate Height

Unit Width

Unit Height

Unit Depth

Faceplate to Vent Centerline

Faceplate Depth

Height to Vent Collar

Optional or Standard Front Depth

June 2007 Regency Product Specifi cations Book

E33

45-9/16” (1157mm)

31-1/8” (791mm)

32-1/4” (819mm)

23-13/16” (605mm)

16-3/4” (426mm)

11-1/4” (286mm)

1-3/8” (35mm)

23” (583mm)

N/A

Minimum Fireplace Dimensions

The minimum fi replace dimensions for the FPI gas fi replace insert are shown in the following diagrams:

J aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa

M

L aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa

Dimension Description

L

M

J

K

N

Height

Width

Depth

Max. Lintel Bar Depth

Rear Width aaaaaaaaaa aaaaaaaaaa

K aaaaaaaaaa aaaaaaaaaa aaaaaaaaaa

N

Contour Faceplate

24-3/16” (614mm)

32-1/4” (819mm)

17” (432mm)

8” (203mm)

25” (635mm)

127

Gas Inserts

E33 Gas Insert

Clearances

Unless otherwise stated the clearances listed below are Minimum distances to combustible materials. Please Note: A major cause of chimney related fi res is due to a failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.

Combustible Mantels

Because of the extreme heat this fi replace emits, the mantel

clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher.

Clearances to Combustibles

Dimension Description E33

D

E

F

A*

B

C

From Unit to Side Walls

From Unit to Ceiling

Minimum Mantel Height

Maximum Mantel Depth

Alcove Width

Alcove Depth

8” (203mm)

47” (1194mm)

15” (381mm)

12” (305mm)

76” (1930mm)

36” (914mm)

G

H

Hearth Height

Hearth Width

1-¼” (32mm)

45-½” (1156mm)

I Hearth Depth 13” (330mm)

* Alcove side wall must have a minimum of 8” (203mm) clearance on one side.

128

D

Flush Front Mantel Clearances

12 10 8 6 4 2

0

20

12" (305mm) Mantel

18

16

47”

(1194mm) to ceiling

14

12

10

8

6

4

2

3-1/2" (89mm) Mantel

20”

(508mm)

15”

(381mm)

0

Top of

Unit

25" (635mm) to floor

Side View

Full Screen Door Mantel Clearances

Note: A non-combustible mantel may be installed at a lower height.

Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.

June 2007 Regency Product Specifi cations Book