advertisement
▼
Scroll to page 2
of 20
5291598-LTG-B-1216 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONER / GAS HEAT 16 SEER – R-410A – 208/230V - 3 PHASE 3 THRU 5 NOMINAL TONS 65 - 125 MBH HEAT INPUT MODELS: PCG6*36 THRU 60 • Operating Efficiency - All PCG6 model gas units provide a minimum AFUE of 81.0% in heating and 16.0 SEER, 12.0 EER rating for cooling operation. All models meet California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. All PCG6 models utilize a multi-stage compressor for maximum comfort and efficiency. • On Site Flexibility - All model sizes use a compact design cabinet. Field convertible duct connections from side flow to downflow allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to ensure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to ensure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. ® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.luxaire.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY* Standard 1-Year limited parts warranty. Standard 5-Years limited compressor warranty. 10-Years gas heat exchanger warranty. *See limited warranty certificate in User’s Information Manual for details • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 6289 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish ensure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5291598-LTG-B-1216 • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of scroll bypass and a temperature sensor which protect the compressor if undesirable operating conditions occur. • More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The uniquely formed base pan also aids in sound attenuation with its structural design. This design strategically places embossments in the pan for optimum strength and rigidity. • Fan System - All models operate over a wide range of design conditions with an enhanced ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. • Simple Control Circuit - A low voltage gas heat printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-nlock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. 2 • Pressure Switches - A high pressure switch is standard in all units. It is an automatic reset switch. When discharge pressure reaches 650 psi, the compressor de-energizes until pressure reaches 450 psi. • Heat Exchangers - Gas heat exchangers use corrosionresistant, stainless-steel tubular construction to provide longlife, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. • Post Purge Induced Draft Combustion - Exhausts combustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. • Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nuisance lockouts. • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. • Low Maintenance - Long life, permanently lubricated outdoor and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. • Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. • Loss of Charge Switch - All models include a loss of charge switch to provide safe shutdown of compressor. • Filter Frame Kit - All 3 phase units include a filter frame kit which is shipped inside the unit from production. Field installation is required. Johnson Controls Unitary Products 5291598-LTG-B-1216 NOMENCLATURE PCG 4 A 24 50 2 X 1 A 1 2 3 4 5 6 7 8 9 1. Model Family PCG - packaged A/C with gas heat, PHG - packaged heat pump with gas heat, PCE - packaged A/C with electric heat, PHE - packaged heat pump with electric heat 5. Gas Heating Input BTU/Hr x 1000 050 = 50,000 BTU/Hr. input, blank = electric heat 2. Nominal Cooling Efficiency 4 = 14 SEER, 6 = 16 SEER, etc. 7. NOx Approval X = low-NOx, blank = not low-Nox 3. Cabinet Size A = small 35 x 51, B = large 45 x 51 8. Generation Level 1 = first generation 4. Nominal Air Conditioning Cooling Capacity BTUx1000 24 = 24,000 BTU, etc. 9. Revision Level A = original release, B = second release 6. Voltage-Phase-Frequency 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 Examples: PHG4B421002X1A is a dual fuel, 14 SEER, 3-1/2 ton, large cabinet, single-stage heat, 100,000 BTU gas heat, 230 volt, single phase, low-NOx model (first generation, first release) COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL (Behind Panel) CONTROL BOARD TRANSFORMER BLOWER MOTOR HIGH VOLTAGE CONTACTOR TXV PRESSURE SWITCH INDOOR COIL DRAFT INDUCER BLOWER INDOOR BLOWER GAS VALVE COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS BURNER ASSEMBLY A0297-001 UNIT LIMITATIONS Model All Models Unit Voltage 208/230-3-60 Johnson Controls Unitary Products Min 187 Unit Limitations Applied Voltage Max 252 Outdoor DB Temp Max (°F) 125 3 5291598-LTG-B-1216 ACCESSORIES • Propane Conversion Kit (S1-1NP0704) - Kit includes burner orifices, gas valve conversion and installation instructions necessary to field convert unit from natural gas to propane. • Economizer for Downflow Applications (S1-2EE04708424, S1-2EE04708524) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design ensures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Economizer for Horizontal Applications (S1-2EE04708624, S1-2EE04708724) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design ensures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Single/Dual Enthalpy Sensor (S1-2EC04700624) - Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. • CO2 Sensor Kit (S1-2AQ04700824) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Outdoor Temp. Sensor Kit (S1-2EC04700724S1-2EC04700724V) - Additional outdoor air temp sensor kit used with economizers. • Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. • Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0110 kit and from rectangle to 14" round for the 1AK0111 kit. • Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. • Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. • Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. • Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) - Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. • Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermostats. All units can operate with a single stage heat thermostat, but requires a multistage thermostat for cooling. • Low Ambient Kit (S1-2LA04701024) - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0º F. Standard unit operation 45º F. • Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides necessary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PCG6* footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PCG6* price pages for more details. 4 Johnson Controls Unitary Products 5291598-LTG-B-1216 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today’s market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21.47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powderpainted steel, certified at 1000 hours salt spray test per ASTMB117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. Johnson Controls Unitary Products Indoor Blower Assembly - Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Indoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. b. Indoor coil shall be of the direct expansion, draw through design. c. Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. d. Outdoor coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXVs) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. 5 5291598-LTG-B-1216 GAS HEATING SECTION (If Equipped) Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(es) (manual reset). d. Flame proving controls. All gas heat models will meet the California requirement for emissions of less than 40 nanograms per Joule (California requirement on single phase models only). PHYSICAL DATA NOMINAL TONNAGE MODELS PCG6B48 4.0 PCG6B36 3.0 PCG6B42 3.5 PCG6B60 5.0 Gross Capacity @ AHRI A point (MBH) 36.5 43.3 49.1 60.0 AHRI net capacity (MBH) 36.0 42.5 48.0 58.0 EER 12.5 12.5 12.5 12.0 SEER 16.0 16.0 16.0 16.0 Nominal CFM 1200 1400 1600 2000 AHRI Cooling Performance 3.0 3.4 3.6 4.6 R410A R410A R410A R410A 11-8 11-2 13-8 14-0 System power (KW) Refrigerant type Refrigerant charge (lb-oz) AHRI Gas Heat Performance Heating model 065 100 065 100 065 100 125 065 100 125 Heat input - High Fire (KBtu) 65 100 65 100 65 100 125 65 100 125 Heat output - High Fire (KBtu) 52 81 52 81 52 81 101 52 81 101 Heat input - Low Fire (KBtu) 43 65 43 65 43 65 82 43 65 82 Heat output - Low Fire (KBtu) 34 53 34 53 34 53 66 34 53 66 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 No. burners 2 3 2 3 2 3 4 2 3 4 No. stages 2 2 2 2 2 2 2 2 2 2 AFUE % Temperature Rise Range - High Fire (°F) 40-70 40-70 40-70 40-70 Temperature Rise Range - Low Fire (°F) 25-55 25-55 25-55 25-55 Max. Static Pressure w.c. 0.5 0.5 0.5 0.5 Max. Outlet Air Temp. (°F) 180 180 180 180 Gas piping connection (in.) 1/2 1/2 1/2 1/2 Length 51-1/4 51-1/4 51-1/4 51-1/4 Width 45-3/4 45-3/4 45-3/4 45-3/4 Height 49 49 53 55 Scroll Scroll Scroll Scroll 2 2 2 2 25.9 Dimensions (inches) Compressor Type Stages Condenser Coil Data Face area (Sq. Ft.) 19.5 19.5 23.8 Rows 2 2 2 2 Fins per inch 22 22 22 22 Tube diameter 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Continued on next page. 6 Johnson Controls Unitary Products 5291598-LTG-B-1216 PHYSICAL DATA (Continued) NOMINAL TONNAGE PCG6B36 3.0 PCG6B42 3.5 MODELS PCG6B48 4.0 PCG6B60 5.0 Evaporator Coil Data Face area (Sq. Ft.) 6.3 6.3 6.3 Rows 3 3 3 4 Fins per inch 16 16 16 16 Tube diameter 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced TXV TXV TXV TXV Refrigerant control 6.3 Condenser Fan Data Fan diameter (Inch) 26 26 26 26 Type Prop Prop Prop Prop Drive type Direct 1 Direct Direct Direct 1 1 1 1/3 1/3 1/3 1/3 No. speeds Motor HP each RPM 850 850 850 850 Nominal total CFM 3200 3200 3200 3200 Direct Drive Evaporator Fan Data Fan Size (Inch) Type Motor HP each RPM Frame size 11 x 10 11 x 10 11 x 10 11 x 10 Centrifugal Centrifugal Centrifugal Centrifugal 1/2 3/4 3/4 1 1200 Max 3/4 1200 Max 1200 Max 1200 Max 48 48 48 48 B B B B Filters Filter Size Quantity - Size Johnson Controls Unitary Products Field-supplied external filters must be sized so as not to exceed 300 fpm air velocity through disposable filters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. 7 5291598-LTG-B-1216 COOLING PERFORMANCE DATA - 3 TON (LOW SPEED) - MODEL NO. PCG6B36 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 34.8 34.1 2.35 33.2 32.4 2.56 31.5 30.7 2.77 30.2 29.1 3.03 28.8 27.4 3.29 25.6 23.7 3.61 22.5 20.1 3.92 19.4 16.5 4.23 80 62 41.4 28.8 2.20 39.0 27.6 2.40 36.6 26.4 2.61 34.7 25.1 2.90 32.7 23.9 3.20 28.5 21.5 3.55 24.4 19.1 3.88 20.4 16.8 4.22 600 75 62 41.7 25.1 2.19 39.2 23.7 2.39 36.7 22.2 2.59 34.1 21.0 2.86 31.5 19.8 3.13 27.8 17.5 3.49 24.2 15.2 3.84 20.6 13.0 4.19 80 67 46.0 25.4 2.16 43.6 24.2 2.36 41.2 22.9 2.57 38.9 21.6 2.84 36.6 20.4 3.11 32.8 18.5 3.48 29.1 16.6 3.83 25.5 14.7 4.19 80 72 49.1 20.5 2.13 47.3 19.5 2.33 45.5 18.4 2.52 42.3 17.0 2.78 39.2 15.7 3.05 35.3 13.9 3.41 31.6 12.1 3.77 27.9 10.4 4.13 80 57 37.3 36.8 2.30 35.4 34.8 2.51 33.5 32.9 2.71 31.6 30.9 2.98 29.6 28.8 3.24 26.1 25.0 3.56 22.6 21.3 3.87 19.2 17.6 4.17 80 62 41.2 32.1 2.16 38.8 30.7 2.37 36.3 29.4 2.57 34.0 28.3 2.85 31.7 27.1 3.13 27.7 24.1 3.49 23.8 21.1 3.83 20.0 18.1 4.18 800 75 62 41.5 27.8 2.16 38.8 26.3 2.36 36.1 24.8 2.56 33.4 23.5 2.83 30.6 22.2 3.09 26.8 19.8 3.46 23.0 17.6 3.82 19.3 15.4 4.18 80 67 44.6 26.7 2.13 42.6 25.9 2.34 40.7 25.0 2.54 38.3 24.0 2.80 36.0 23.0 3.07 31.7 20.8 3.44 27.5 18.7 3.79 23.2 16.6 4.15 80 72 47.3 21.0 2.11 45.7 20.3 2.31 44.2 19.6 2.50 41.2 18.2 2.76 38.1 16.8 3.02 33.9 14.8 3.39 29.8 12.9 3.74 25.7 11.0 4.10 80 57 39.7 39.4 2.25 37.6 37.3 2.46 35.4 35.1 2.66 33.0 32.7 2.92 30.5 30.2 3.19 26.5 26.3 3.50 22.7 22.5 3.81 18.9 18.7 4.11 80 62 41.0 35.4 2.13 38.5 33.9 2.33 36.0 32.4 2.53 33.3 31.4 2.80 30.7 30.4 3.06 26.9 26.7 3.43 23.2 23.0 3.78 19.6 19.4 4.14 1000 75 62 41.2 30.6 2.13 38.4 28.9 2.33 35.6 27.3 2.54 32.7 25.9 2.80 29.8 24.5 3.06 25.7 22.2 3.44 21.8 20.0 3.80 17.9 17.7 4.17 80 67 43.1 28.0 2.11 41.7 27.6 2.31 40.2 27.2 2.51 37.8 26.4 2.77 35.4 25.6 3.03 30.5 23.2 3.40 25.8 20.9 3.76 21.0 18.5 4.12 80 72 45.4 21.5 2.09 44.2 21.2 2.29 42.9 20.8 2.48 40.0 19.4 2.74 37.1 17.9 2.99 32.4 15.8 3.36 27.9 13.7 3.72 23.4 11.7 4.07 80 72 48.4 12.8 2.17 46.6 17.9 2.37 44.7 22.9 2.57 42.6 21.3 2.83 40.4 19.8 3.09 37.0 18.3 3.48 33.7 16.9 3.86 30.4 15.5 4.24 80 57 43.8 40.6 2.20 42.1 39.0 2.40 40.4 37.4 2.61 38.3 35.3 2.87 36.2 33.2 3.13 32.7 30.7 3.52 29.3 28.2 3.90 25.9 25.7 4.29 80 62 44.6 38.7 2.20 42.2 38.0 2.40 39.8 37.3 2.61 37.1 35.7 2.87 34.3 34.1 3.13 31.2 30.9 3.52 28.1 27.9 3.90 25.0 24.8 4.29 1400 75 62 43.5 32.5 2.20 41.2 31.7 2.40 38.9 30.9 2.59 36.3 29.5 2.85 33.7 28.1 3.11 30.2 26.3 3.51 26.8 24.5 3.88 23.4 22.8 4.26 80 67 48.0 32.0 2.24 45.5 31.4 2.44 43.0 30.8 2.64 40.1 29.5 2.90 37.2 28.2 3.15 33.5 26.6 3.54 29.8 25.2 3.91 26.1 23.7 4.29 80 72 50.2 25.0 2.25 48.9 24.1 2.46 47.5 23.3 2.67 44.8 22.2 2.92 42.1 21.1 3.17 38.3 19.6 3.56 34.6 18.1 3.94 30.9 16.6 4.31 COOLING PERFORMANCE DATA - 3 TON (HIGH SPEED) - MODEL NO. PCG6B36 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 8 ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 38.5 36.0 2.02 37.1 34.6 2.21 35.6 33.3 2.41 33.9 31.6 2.68 32.2 29.8 2.94 29.4 27.8 3.34 26.7 25.7 3.74 24.1 23.7 4.13 80 62 41.0 32.3 2.04 38.7 31.4 2.24 36.3 30.5 2.43 34.1 29.4 2.69 31.9 28.2 2.95 29.0 26.5 3.35 26.1 24.8 3.73 23.3 23.1 4.11 1000 75 62 40.0 27.5 2.03 32.0 25.6 3.08 24.1 23.7 4.13 27.9 23.5 3.54 31.7 23.2 2.95 28.8 21.8 3.35 25.9 20.4 3.73 23.1 18.9 4.11 80 67 43.2 27.7 2.07 41.6 26.7 2.27 40.1 25.7 2.47 37.4 24.6 2.73 34.8 23.4 2.99 31.6 22.0 3.38 28.4 20.5 3.76 25.3 19.1 4.14 80 72 46.6 0.6 2.09 44.3 11.6 2.29 41.9 22.5 2.48 40.3 20.5 2.74 38.7 18.5 3.00 35.7 17.1 3.40 32.8 15.8 3.78 29.9 14.4 4.16 80 57 41.2 38.3 2.11 39.6 36.8 2.31 38.0 35.3 2.51 36.1 33.4 2.77 34.2 31.5 3.03 31.0 29.2 3.43 28.0 27.0 3.82 25.0 24.7 4.21 80 62 42.8 35.5 2.12 40.4 34.7 2.32 38.1 33.9 2.52 35.6 32.5 2.78 33.1 31.2 3.04 30.1 28.7 3.43 27.1 26.4 3.82 24.1 24.0 4.20 1200 75 62 41.7 30.0 2.12 36.6 28.6 2.74 31.5 27.3 3.36 32.1 26.5 3.20 32.7 25.7 3.03 29.5 24.0 3.43 26.4 22.4 3.81 23.3 20.9 4.19 80 67 45.6 29.9 2.15 43.6 29.1 2.35 41.5 28.2 2.55 38.8 27.0 2.81 36.0 25.8 3.07 32.5 24.3 3.46 29.1 22.8 3.84 25.7 21.4 4.21 Johnson Controls Unitary Products 5291598-LTG-B-1216 COOLING PERFORMANCE DATA - 3.5 TON (LOW SPEED) - MODEL NO. PCG6B42 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 30.2 29.7 0.97 27.7 27.3 1.13 25.2 25.0 1.29 22.4 22.2 1.48 19.6 19.4 1.67 17.0 16.8 1.94 14.5 14.4 2.19 12.0 11.9 2.45 80 62 33.8 26.3 0.96 32.0 25.4 1.11 30.1 24.5 1.26 27.0 22.4 1.47 23.9 20.3 1.68 20.4 18.0 1.94 17.0 15.8 2.20 13.6 13.5 2.45 800 75 62 24.4 23.9 0.93 23.2 22.6 1.09 22.1 21.2 1.25 21.1 20.2 1.45 20.1 19.2 1.66 18.8 17.9 1.92 17.5 16.6 2.17 16.2 15.3 2.42 80 67 36.3 21.8 0.98 34.8 21.3 1.14 33.3 20.9 1.29 31.1 19.6 1.49 28.9 18.3 1.68 25.0 17.6 1.94 21.2 17.0 2.19 17.4 16.3 2.44 80 72 39.4 18.2 0.98 37.3 17.5 1.10 35.1 16.9 1.22 34.4 16.0 1.43 33.8 15.0 1.63 29.8 13.4 1.90 25.8 11.9 2.16 21.9 10.3 2.42 80 57 33.3 32.0 0.97 30.3 29.5 1.13 27.2 27.0 1.28 24.1 23.9 1.48 21.0 20.9 1.69 18.6 18.4 1.95 16.2 16.1 2.20 13.9 13.7 2.46 80 62 36.0 29.6 0.97 34.0 28.7 1.12 32.0 27.8 1.27 29.0 25.8 1.48 26.0 23.7 1.69 22.2 20.6 1.95 18.4 17.6 2.20 14.7 14.6 2.46 1000 75 62 26.3 25.8 0.94 25.4 24.7 1.09 24.6 23.6 1.24 23.5 22.5 1.45 22.5 21.4 1.66 21.1 20.0 1.92 19.8 18.6 2.18 18.5 17.3 2.44 80 67 37.9 23.8 1.00 36.6 23.6 1.15 35.3 23.5 1.30 33.0 22.2 1.49 30.7 21.0 1.69 27.0 20.2 1.95 23.4 19.3 2.20 19.8 18.5 2.45 80 72 40.4 19.3 1.00 38.9 19.0 1.11 37.5 18.7 1.23 35.8 17.6 1.44 34.1 16.5 1.64 31.3 14.9 1.91 28.7 13.3 2.17 26.0 11.7 2.43 80 57 36.4 34.4 0.97 32.8 31.7 1.12 29.2 29.0 1.27 25.9 25.7 1.48 22.5 22.3 1.70 20.2 20.0 1.96 18.0 17.8 2.21 15.8 15.6 2.47 80 62 38.2 32.8 0.97 36.0 31.9 1.13 33.9 31.1 1.28 31.0 29.1 1.49 28.2 27.1 1.70 23.9 23.2 1.96 19.8 19.4 2.21 15.8 15.6 2.47 1200 75 62 28.1 27.6 0.94 27.6 26.8 1.09 27.1 26.0 1.24 26.0 24.8 1.45 24.8 23.6 1.66 23.4 22.1 1.93 22.0 20.7 2.19 20.7 19.3 2.46 80 67 39.5 25.9 1.01 38.4 25.9 1.15 37.3 26.0 1.30 34.9 24.8 1.50 32.5 23.7 1.70 29.0 22.7 1.95 25.6 21.7 2.20 22.1 20.8 2.45 80 72 41.3 20.4 1.01 40.6 20.5 1.13 40.0 20.5 1.25 37.2 19.3 1.45 34.4 18.0 1.65 32.9 16.3 1.92 31.5 14.7 2.18 30.1 13.1 2.44 80 62 51.4 42.4 2.39 49.3 41.8 2.65 47.1 41.2 2.91 42.9 37.6 3.22 38.8 34.0 3.54 34.4 31.0 4.00 30.1 28.2 4.44 25.8 25.4 4.88 1520 75 62 32.8 31.9 2.36 33.6 32.4 2.64 34.5 33.0 2.91 34.3 32.7 3.26 34.1 32.4 3.61 32.5 30.7 4.07 31.0 29.2 4.52 29.5 27.6 4.97 80 67 52.8 32.3 2.27 51.8 32.6 2.54 50.8 32.9 2.80 47.3 32.2 3.20 43.8 31.6 3.59 39.4 29.5 3.97 35.2 27.4 4.35 30.9 25.4 4.73 80 72 56.7 24.5 2.26 56.7 25.4 2.61 56.6 26.4 2.95 54.0 24.8 3.28 51.4 23.3 3.60 46.8 21.5 4.05 42.4 19.7 4.49 37.9 18.0 4.93 COOLING PERFORMANCE DATA - HIGH - 3.5 TON (HIGH SPEED) - MODEL NO. PCG6B42 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 Johnson Controls Unitary Products ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 43.6 41.7 2.19 39.9 38.6 2.44 36.1 35.5 2.68 33.3 32.8 3.02 30.5 30.0 3.35 27.9 27.5 3.81 25.4 25.0 4.25 22.9 22.5 4.69 80 62 47.7 36.8 2.22 45.2 35.7 2.46 42.7 34.6 2.71 39.4 33.0 3.03 36.0 31.4 3.35 32.6 29.1 3.81 29.3 26.9 4.25 25.9 24.7 4.69 1120 75 62 30.8 29.9 2.17 31.1 29.9 2.43 31.4 29.9 2.69 30.5 29.0 3.05 29.7 28.1 3.40 28.2 26.6 3.87 26.8 25.1 4.32 25.4 23.7 4.78 80 67 50.0 30.0 2.16 49.1 29.6 2.42 48.3 29.2 2.67 45.2 27.8 3.04 42.0 26.4 3.41 38.0 24.7 3.82 34.1 23.0 4.21 30.3 21.3 4.61 80 72 55.0 23.2 2.16 53.4 23.2 2.46 51.8 23.2 2.77 49.9 22.0 3.09 48.0 20.9 3.41 44.3 19.2 3.86 40.6 17.6 4.30 37.0 15.9 4.74 80 57 45.8 43.7 2.29 41.9 40.5 2.54 38.0 37.3 2.79 35.2 34.5 3.12 32.3 31.7 3.45 29.5 29.0 3.90 26.7 26.3 4.35 24.0 23.6 4.79 80 62 49.6 39.6 2.30 47.2 38.8 2.56 44.9 37.9 2.81 41.2 35.3 3.13 37.4 32.7 3.45 33.5 30.1 3.90 29.7 27.6 4.34 25.9 25.1 4.78 1320 75 62 31.8 30.9 2.26 32.4 31.2 2.53 33.0 31.4 2.80 32.4 30.8 3.16 31.9 30.2 3.51 30.4 28.7 3.97 28.9 27.2 4.42 27.4 25.6 4.87 80 67 51.4 31.2 2.22 50.5 31.1 2.48 49.6 31.1 2.74 46.2 30.0 3.12 42.9 29.0 3.50 38.7 27.1 3.90 34.7 25.2 4.28 30.6 23.4 4.67 80 72 55.8 23.8 2.21 55.0 24.3 2.54 54.2 24.8 2.86 52.0 23.4 3.18 49.7 22.1 3.51 45.5 20.3 3.96 41.5 18.6 4.39 37.5 17.0 4.83 80 57 48.1 45.8 2.39 44.0 42.5 2.64 39.9 39.2 2.90 37.0 36.3 3.22 34.1 33.5 3.54 31.0 30.5 4.00 28.0 27.5 4.44 25.1 24.6 4.89 9 5291598-LTG-B-1216 COOLING PERFORMANCE DATA - 4 TON (LOW SPEED) - MODEL NO. PCG6B48 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 34.3 32.3 1.67 32.4 30.4 1.86 30.4 28.6 2.05 27.3 26.2 2.39 24.2 23.8 2.72 21.9 21.5 3.15 19.6 19.3 3.56 17.3 17.0 3.98 80 62 37.4 28.7 1.64 34.5 27.4 1.83 31.6 26.0 2.03 29.1 23.9 2.36 26.7 21.8 2.68 23.6 20.3 3.16 20.6 18.8 3.63 17.6 17.4 4.10 900 75 62 36.3 24.7 1.65 34.1 21.0 1.85 32.0 17.4 2.04 28.2 18.1 2.43 24.5 18.8 2.82 20.8 17.0 3.22 17.1 15.1 3.60 13.5 13.3 3.98 80 67 41.1 24.9 1.63 38.7 23.5 1.79 36.3 22.1 1.96 34.0 20.8 2.37 31.6 19.4 2.78 27.3 19.1 3.16 23.2 18.8 3.53 19.1 18.6 3.91 80 72 45.6 20.0 1.49 43.8 18.9 1.73 42.0 17.8 1.97 39.1 16.5 2.30 36.1 15.1 2.63 32.6 13.6 3.06 29.2 12.2 3.47 25.7 10.7 3.89 80 57 37.5 34.8 1.63 35.2 32.8 1.85 33.0 30.7 2.07 29.4 28.0 2.41 25.8 25.4 2.74 23.1 22.7 3.17 20.4 20.1 3.58 17.7 17.4 3.99 80 62 39.7 32.1 1.61 36.8 30.2 1.83 33.9 28.2 2.05 31.1 26.6 2.38 28.2 25.0 2.72 24.7 22.5 3.17 21.2 20.0 3.61 17.8 17.5 4.05 1100 75 62 38.7 27.2 1.62 36.6 23.2 1.84 34.5 19.1 2.06 29.9 19.9 2.42 25.3 20.8 2.78 21.1 18.0 3.20 16.9 15.3 3.60 12.7 12.5 4.00 80 67 43.6 27.2 1.59 41.0 25.8 1.82 38.4 24.4 2.05 35.7 22.9 2.39 33.1 21.5 2.74 29.0 21.1 3.14 25.0 20.8 3.53 21.0 20.4 3.92 80 72 48.0 21.8 1.52 46.2 20.7 1.76 44.5 19.6 2.01 41.2 18.0 2.33 37.9 16.4 2.65 33.9 14.7 3.09 30.1 13.0 3.51 26.3 11.4 3.93 80 57 40.6 37.4 1.58 38.1 35.1 1.84 35.5 32.9 2.10 31.4 29.9 2.43 27.4 26.9 2.76 24.2 23.9 3.18 21.2 20.9 3.59 18.2 17.9 4.00 80 62 42.1 35.5 1.58 39.1 33.0 1.82 36.2 30.5 2.06 33.0 29.3 2.41 29.7 28.2 2.75 25.7 24.6 3.18 21.8 21.1 3.60 17.9 17.6 4.01 1300 75 62 41.1 29.8 1.58 39.1 25.3 1.83 37.1 20.8 2.08 31.6 21.8 2.41 26.2 22.8 2.74 21.3 19.0 3.18 16.6 15.4 3.60 11.9 11.8 4.02 80 67 46.2 29.6 1.56 43.3 28.1 1.84 40.4 26.6 2.13 37.5 25.1 2.42 34.6 23.6 2.70 30.6 23.2 3.12 26.8 22.7 3.53 22.9 22.3 3.93 80 72 50.3 23.6 1.55 48.7 22.5 1.79 47.0 21.5 2.04 43.4 19.5 2.36 39.7 17.6 2.68 35.3 15.7 3.12 31.1 13.9 3.54 26.8 12.1 3.97 80 62 54.3 45.2 2.88 52.1 31.7 3.06 49.9 18.2 3.25 46.1 28.9 3.67 42.3 39.7 4.09 38.3 36.5 4.60 34.5 33.5 5.09 30.7 30.4 5.58 1800 75 62 55.6 38.2 2.87 53.3 40.0 3.14 51.0 41.8 3.41 47.2 37.2 3.75 43.4 32.6 4.08 38.9 25.1 4.52 34.5 17.9 4.95 30.1 10.6 5.39 80 67 56.9 35.0 2.90 54.9 35.5 3.19 52.8 36.0 3.47 48.9 34.4 3.81 45.1 32.7 4.15 40.9 30.9 4.65 36.8 29.1 5.13 32.7 27.3 5.62 80 72 60.1 28.1 2.89 59.1 36.5 3.20 58.1 44.9 3.50 54.2 34.9 3.85 50.3 25.0 4.19 45.7 22.9 4.68 41.2 20.8 5.17 36.7 18.8 5.65 COOLING PERFORMANCE DATA - HIGH - 4 TON (HIGH SPEED) - MODEL NO. PCG6B48 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 10 ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 46.5 45.7 2.66 43.8 43.3 2.93 41.1 41.0 3.19 40.3 39.8 3.55 39.4 38.6 3.91 34.6 34.0 4.42 29.9 29.5 4.91 25.2 25.0 5.41 80 62 54.3 41.3 2.72 51.2 40.2 3.06 48.2 39.1 3.39 45.2 37.3 3.66 42.2 35.5 3.93 37.5 33.1 4.49 33.0 30.7 5.03 28.4 28.4 5.58 1400 75 62 55.5 35.4 2.72 52.2 34.1 2.98 48.8 32.9 3.24 46.3 31.1 3.58 43.8 29.3 3.92 39.1 27.4 4.43 34.6 25.5 4.92 30.1 23.6 5.41 80 67 56.6 35.0 2.93 54.8 33.8 3.11 52.9 32.6 3.29 49.4 31.2 3.72 45.9 29.7 4.15 41.7 27.8 4.65 37.7 26.0 5.14 33.6 24.2 5.62 80 72 59.6 27.8 2.75 58.3 27.0 3.13 56.9 26.1 3.51 53.8 24.6 3.77 50.7 23.1 4.03 46.5 21.2 4.58 42.4 19.3 5.12 38.2 17.5 5.66 80 57 47.9 47.2 2.76 44.9 44.3 3.03 42.0 41.5 3.29 40.1 39.4 3.64 38.1 37.4 4.00 34.0 33.4 4.51 30.0 29.6 5.00 26.0 25.8 5.50 80 62 54.3 43.3 2.80 51.7 35.9 3.06 49.1 28.6 3.32 45.6 33.1 3.67 42.2 37.6 4.01 37.9 34.8 4.54 33.8 32.1 5.06 29.6 29.4 5.58 1600 75 62 55.6 36.8 2.80 52.7 37.0 3.06 49.9 37.3 3.33 46.8 34.1 3.66 43.6 30.9 4.00 39.0 26.2 4.47 34.5 21.7 4.94 30.1 17.1 5.40 80 67 56.8 35.0 2.92 54.8 34.7 3.15 52.9 34.3 3.38 49.2 32.8 3.77 45.5 31.2 4.15 41.3 29.3 4.65 37.2 27.6 5.13 33.2 25.8 5.62 80 72 59.9 28.0 2.82 58.7 31.7 3.16 57.5 35.5 3.51 54.0 29.8 3.81 50.5 24.1 4.11 46.1 22.0 4.63 41.8 20.1 5.14 37.5 18.1 5.66 80 57 49.2 48.7 2.86 46.1 45.3 3.13 43.0 41.9 3.39 39.9 39.1 3.74 36.8 36.2 4.09 33.4 32.9 4.59 30.1 29.8 5.09 26.8 26.6 5.58 Johnson Controls Unitary Products 5291598-LTG-B-1216 COOLING PERFORMANCE DATA - 5 TON (LOW SPEED) - MODEL NO. PCG6B60 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 44.6 44.6 1.77 42.1 42.1 2.05 39.6 39.6 2.34 36.5 36.5 2.69 33.4 33.4 3.04 30.0 30.0 3.56 26.7 26.7 4.07 23.4 23.4 4.57 80 62 51.1 43.1 1.77 47.6 41.4 2.05 44.2 39.6 2.33 40.6 37.6 2.67 37.0 35.5 3.02 34.0 32.8 3.48 31.1 30.3 3.93 28.3 27.7 4.38 1100 75 62 50.5 36.8 1.77 46.8 35.0 2.14 43.1 33.3 2.51 39.8 31.4 2.87 36.4 29.5 3.23 32.7 27.2 3.62 29.0 25.0 4.00 25.3 22.8 4.39 80 67 55.7 36.5 1.74 52.1 34.9 2.11 48.5 33.3 2.48 44.8 31.4 2.74 41.0 29.5 3.00 36.5 27.4 3.46 32.1 25.4 3.91 27.7 23.4 4.35 80 72 59.9 30.0 1.90 57.3 28.5 2.08 54.8 26.9 2.26 50.8 25.1 2.61 46.9 23.2 2.96 42.1 21.2 3.43 37.4 19.2 3.87 32.7 17.2 4.32 80 57 47.1 47.1 1.87 44.3 44.3 2.15 41.6 41.6 2.43 38.3 38.3 2.78 35.0 35.0 3.13 31.3 31.3 3.62 27.8 27.8 4.10 24.3 24.3 4.58 80 62 53.0 47.5 1.87 49.4 45.6 2.15 45.8 43.8 2.42 41.8 40.9 2.77 37.8 37.8 3.13 34.3 34.3 3.59 30.9 30.9 4.03 27.5 27.5 4.47 1300 75 62 51.7 40.0 1.88 48.4 38.1 2.20 45.1 36.2 2.51 41.5 34.2 2.87 37.8 32.2 3.23 33.6 29.6 3.66 29.4 27.1 4.07 25.3 24.6 4.49 80 67 57.4 39.4 1.84 53.9 37.8 2.16 50.3 36.2 2.48 46.3 34.3 2.79 42.3 32.3 3.10 37.3 30.1 3.56 32.5 28.0 4.01 27.6 25.9 4.46 80 72 61.8 31.6 1.92 59.6 30.2 2.14 57.4 28.7 2.36 53.0 26.8 2.71 48.5 25.0 3.07 43.3 22.7 3.53 38.3 20.6 3.98 33.2 18.4 4.43 80 57 49.5 49.5 1.98 46.6 46.6 2.25 43.7 43.7 2.52 40.1 40.1 2.87 36.5 36.5 3.22 32.7 32.7 3.69 28.9 28.9 4.13 25.1 25.1 4.58 80 62 54.9 51.8 1.98 51.2 49.9 2.24 47.4 47.4 2.51 43.0 43.0 2.88 38.6 38.6 3.25 34.6 34.6 3.70 30.6 30.6 4.13 26.7 26.7 4.57 1500 75 62 53.0 43.3 1.99 50.1 41.2 2.25 47.1 39.1 2.52 43.2 37.0 2.88 39.3 34.9 3.24 34.5 32.0 3.70 29.9 29.2 4.14 25.2 25.2 4.59 80 67 59.2 42.4 1.94 55.7 40.8 2.22 52.1 39.2 2.49 47.9 37.2 2.84 43.6 35.1 3.20 38.1 32.9 3.66 32.8 30.7 4.11 27.5 27.5 4.56 80 72 63.8 33.3 1.94 61.9 31.9 2.20 60.1 30.4 2.45 55.1 28.6 2.81 50.2 26.7 3.17 44.6 24.3 3.63 39.1 21.9 4.09 33.7 19.6 4.54 80 72 77.7 38.2 3.14 75.5 46.7 3.51 73.4 55.3 3.89 68.6 43.3 4.17 63.9 31.4 4.44 58.7 29.3 5.00 53.8 27.2 5.54 48.8 25.1 6.09 80 57 63.5 63.5 3.26 57.2 57.2 3.53 50.9 50.9 3.80 46.8 46.8 4.16 42.8 42.8 4.52 38.9 38.9 5.03 35.1 35.1 5.54 31.4 31.4 6.04 80 62 72.3 63.4 3.30 68.1 31.9 3.42 64.0 0.3 3.55 59.2 26.7 4.04 54.3 53.0 4.53 49.5 48.7 5.04 44.9 44.5 5.54 40.2 40.2 6.04 2000 75 62 68.8 52.2 3.30 64.7 56.8 3.56 60.6 60.6 3.83 56.8 52.7 4.17 53.0 43.9 4.51 48.3 29.1 4.92 43.8 14.7 5.33 39.3 0.3 5.74 80 67 75.1 51.5 3.34 71.3 49.8 3.62 67.4 48.0 3.90 62.4 45.7 4.25 57.4 43.3 4.60 52.3 41.1 5.11 47.4 39.0 5.61 42.5 36.8 6.11 80 72 78.3 39.1 3.35 76.9 57.8 3.66 75.4 75.4 3.97 70.2 54.5 4.32 64.9 32.6 4.66 59.6 30.4 5.17 54.4 28.2 5.66 49.3 26.1 6.16 COOLING PERFORMANCE DATA - 5 TON (HIGH SPEED) - MODEL NO. PCG6B60 CONDENSER ENTERING AIR TEMPERATURE 55 / 45 65 / 55 75 / 63 85 / 69 95 / 75 105 / 83 115 / 89 125 / 95 Johnson Controls Unitary Products ID CFM IDDB IDWB T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 80 57 59.2 59.2 2.80 54.3 54.3 3.07 49.3 49.3 3.33 48.7 48.7 3.71 48.0 48.0 4.09 42.5 42.5 4.60 37.0 37.0 5.10 31.6 31.6 5.60 80 62 68.9 55.8 2.86 64.1 53.9 3.25 59.2 52.0 3.65 55.4 49.6 3.87 51.6 47.2 4.10 46.6 43.9 4.71 41.8 40.7 5.29 37.0 37.0 5.88 1600 75 62 66.5 47.0 2.87 61.7 45.4 3.13 57.0 43.7 3.39 53.9 41.4 3.74 50.7 39.1 4.09 45.9 36.8 4.61 41.3 34.7 5.12 36.6 32.5 5.63 80 67 71.8 46.7 3.21 68.4 44.9 3.34 65.1 43.0 3.47 60.5 41.0 3.95 55.9 39.1 4.44 50.9 36.9 4.96 46.0 34.7 5.46 41.1 32.6 5.96 80 72 77.1 37.2 2.93 74.2 35.7 3.37 71.3 34.2 3.81 67.1 32.2 4.02 62.8 30.3 4.23 57.9 28.2 4.84 53.1 26.2 5.43 48.2 24.2 6.01 80 57 61.3 61.3 3.03 55.7 55.7 3.30 50.1 50.1 3.57 47.8 47.8 3.94 45.4 45.4 4.30 40.7 40.7 4.82 36.1 36.1 5.32 31.5 31.5 5.82 80 62 70.6 59.6 3.08 66.1 42.9 3.34 61.6 26.2 3.60 57.3 38.2 3.96 53.0 50.1 4.31 48.1 46.3 4.87 43.4 42.6 5.42 38.6 38.6 5.96 1800 75 62 67.6 49.6 3.08 63.2 51.1 3.35 58.8 52.5 3.61 55.3 47.0 3.96 51.8 41.5 4.30 47.1 33.0 4.77 42.5 24.7 5.23 37.9 16.4 5.68 80 67 73.5 49.1 3.28 69.9 47.3 3.48 66.3 45.5 3.68 61.5 43.3 4.10 56.7 41.2 4.52 51.6 39.0 5.04 46.7 36.9 5.54 41.8 34.7 6.04 11 5291598-LTG-B-1216 COIL GUARD HIGH VOLTAGE CONNECTION 7/8” C HIGH VOLTAGE CONNECTION 1-3/32” COMBUSTION AIR INTAKE HEAT EXCHANGER ACCESS PANEL COMPRESSOR ACCESS PANEL EXHAUST HOOD CONDENSATE DRAIN BLOWER ACCESS PANEL A B LOW VOLTAGE CONNECTION GAS SUPPLY CONTROL ACCESS PANEL A0296-001 UNIT DIMENSIONS Model A 51-1/4 51-1/4 51-1/4 51-1/4 36 42 48 60 Dimensions B 45-3/4 45-3/4 45-3/4 45-3/4 C 49 49 53 55 UNIT CLEARANCES1 2 Direction Distance (in.) Direction Distance (in.) Top3 36 Power Entry (Right Side) 36 Side Opposite Ducts 36 Left Side 24 Duct Panel 0 Bottom4 1 NOTES: 1. 2. 3. 4. A 1" clearance must be provided between any combustible material and the supply air duct work. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. Units may be installed on combustible materials made from wood or class A, B or C roof covering materials only if factory base rails are left in place as shipped. INDOOR BLOWER SPECIFICATIONS Motor Model HP RPM EFF. SF 36065 1/2 Variable 0.8 1.0 Frame 48 36100, 42065. 42100, 48065, 48100, 48125 3/4 Variable 0.8 1.0 48 60065, 60100, 60125 1 Variable 0.8 1.0 48 SOUND PERFORMANCE Model (Tons) 36 42 48 60 Sound Rating1 dB (A) 74 74 74 76 125 58.5 63.5 63.5 72.3 250 61.8 63.9 63.9 65.0 Octave Band Centerline Frequency (Hz) 500 1000 2000 65.4 66.5 60.7 62.3 65 64 62.3 65 64 63.9 64 60 4000 54.8 54.1 54.1 55.5 8000 49.8 46.6 46.6 49.0 NOTES: 1. Rated in accordance with AHRI Standard 270. 12 Johnson Controls Unitary Products 5291598-LTG-B-1216 ELECTRICAL DATA Model Compressor Voltage 36065 36100 42065, 42100 48065, 48100, 48125 60065, 60100, 60125 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 OD Fan Motor Supply Blower Motor RLA LRA MCC FLA FLA 11.6 11.6 14.2 14.0 16.2 73.0 73.0 88.0 83.1 110.0 18.1 18.1 22.1 21.9 25.3 1.7 1.7 1.7 1.7 1.7 3.8 5.4 5.4 5.4 7.0 MCA1 (Amps) Max Fuse2/ Breaker3 Size (Amps) 20.0 21.6 24.9 24.6 29.0 30 30 35 35 40 NOTES: 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker to be field installed. "D" CENTER OF GRAVITY COMPRESSOR "C" "A" FRONT OF UNIT X Y "B" A0295-001-TG WEIGHTS & DIMENSIONS Model 36065 36100 42065 42100 48065 48100 48125 60065 60100 60125 Weight (lbs.) Shipping Operating 466 461 473 468 500 495 502 497 520 515 528 523 533 528 537 532 541 536 548 543 Johnson Controls Unitary Products Center of Gravity X Y 28 15 28 15 28 15 28 15 28 15 28 15 28 15 29 15 28 15 27 15 A 161 163 175 176 189 169 164 174 177 151 4 Point Load Location (lbs.) B C 113 96 114 101 123 104 124 101 116 93 139 115 145 124 142 124 140 117 167 141 D 91 90 93 96 117 100 95 92 102 84 13 5291598-LTG-B-1216 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION Model 0.1 0.2 SCFM SCFM A 1371 1354 B 1293 1246 High Cool C 1232 1178 D 1058 999 A 1153 1095 B 1015 952 Low Cool C 882 805 D 805 718 36065 A 1126 1067 B 1015 952 High Heat C 955 886 D 910 836 A 970 902 B 818 732 Low Heat C 766 674 D 721 625 A 1374 1333 B 1304 1260 High Cool C 1233 1186 D 1063 1006 A 1120 1067 B 1025 966 Low Cool C 882 812 D 821 746 36100 A 1704 1667 B 1506 1468 High Heat C 1322 1278 D 1251 1205 A 1392 1352 B 1251 1205 Low Heat C 1139 1087 D 984 922 A 1555 1518 B 1473 1435 High Cool C 1374 1333 D 1216 1168 A 1233 1186 B 1139 1087 Low Cool C 1025 966 D 964 900 42065 A 1120 1067 B 1063 1006 High Heat C 964 900 D 882 812 A 1101 1047 B 923 856 Low Heat C 821 746 D 735 655 A 1555 1518 B 1473 1435 High Cool C 1374 1333 D 1216 1168 A 1233 1186 B 1139 1087 Low Cool C 1025 966 D 964 900 42100 A 1704 1667 B 1506 1468 High Heat C 1322 1278 D 1251 1205 A 1392 1352 B 1251 1205 Low Heat C 1139 1087 D 984 922 Continued on next pages. See notes at end of table. 14 Jumper Position 0.3 SCFM 1303 1206 1131 931 1036 884 741 642 1006 884 821 774 837 659 593 540 1298 1218 1137 937 1004 892 716 641 1645 1441 1238 1157 1318 1157 1027 841 1494 1406 1298 1117 1137 1027 892 816 1004 937 816 716 982 766 641 533 1494 1406 1298 1117 1137 1027 892 816 1645 1441 1238 1157 1318 1157 1027 841 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 1257 1209 1148 1084 1152 1098 1028 938 929 853 1077 1012 859 762 694 635 979 899 810 751 802 709 646 582 501 415 625 556 523 436 376 294 945 860 777 718 802 709 646 582 584 508 721 642 661 592 537 453 742 659 599 527 540 456 397 314 314 234 473 377 413 314 251 172 1255 1204 1145 1100 1170 1116 1055 1007 965 915 1085 1029 871 806 735 678 944 882 813 758 823 756 684 625 480 412 633 559 552 475 392 321 1612 1572 1520 1477 1404 1358 1302 1259 1077 1030 1191 1138 1107 1051 987 938 1276 1226 1168 1123 1107 1051 987 938 839 785 968 907 769 700 625 564 1459 1414 1360 1318 1368 1320 1264 1220 1145 1100 1255 1204 1064 1007 942 892 1085 1029 965 915 968 907 839 785 684 625 823 756 596 534 742 672 944 882 813 758 735 678 871 806 742 672 596 534 480 412 633 559 919 857 787 732 538 473 688 616 552 475 392 321 266 189 435 353 1459 1414 1360 1318 1264 1220 1368 1320 1255 1204 1145 1100 942 892 1064 1007 1085 1029 965 915 839 785 968 907 823 756 684 625 596 534 742 672 1612 1572 1520 1477 1302 1259 1404 1358 1191 1138 1077 1030 987 938 1107 1051 1276 1226 1168 1123 987 938 1107 1051 968 907 839 785 625 564 769 700 0.8 SCFM 1008 865 790 582 697 528 359 247 664 528 453 396 472 265 190 131 1044 953 861 628 707 575 366 276 1419 1203 975 884 1067 884 733 515 1261 1164 1044 838 861 733 575 485 707 628 485 366 680 426 276 147 1261 1164 1044 838 861 733 575 485 1419 1203 975 884 1067 884 733 515 0.9 SCFM 934 813 738 523 643 467 297 193 608 467 391 333 410 211 142 102 993 896 799 550 635 494 270 174 1384 1159 920 824 1017 824 663 430 1220 1119 993 775 799 663 494 398 635 550 398 270 606 334 174 100 1220 1119 993 775 799 663 494 398 1384 1159 920 824 1017 824 663 430 1.0 SCFM 878 767 690 459 588 402 228 118 551 402 324 265 343 136 63 53 933 834 736 484 569 427 199 101 1327 1101 859 761 957 761 598 361 1162 1060 933 712 736 598 427 329 569 484 329 199 541 264 101 85 1162 1060 933 712 736 598 427 329 1327 1101 859 761 957 761 598 361 Johnson Controls Unitary Products 5291598-LTG-B-1216 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued) Model Jumper Position 0.1 0.2 SCFM SCFM A 1851 1809 B 1689 1652 High Cool C 1614 1578 D 1374 1333 A 1473 1435 B 1374 1333 Low Cool C 1322 1278 D 1286 1241 48065 A 1120 1067 B 1063 1006 High Heat C 964 900 D 882 812 A 1101 1047 B 923 856 Low Heat C 821 746 D 735 655 A 1851 1809 B 1689 1652 High Cool C 1614 1578 D 1374 1333 A 1473 1435 B 1374 1333 Low Cool C 1322 1278 D 1286 1241 48100 A 1704 1667 B 1506 1468 High Heat C 1322 1278 D 1251 1205 A 1392 1352 B 1251 1205 Low Heat C 1139 1087 D 984 922 A 1851 1809 B 1689 1652 High Cool C 1614 1578 D 1374 1333 A 1473 1435 B 1374 1333 Low Cool C 1322 1278 D 1286 1241 48125 A 2114 2046 B 1982 1930 High Heat C 1785 1746 D 1614 1578 A 2114 2046 B 1982 1930 Low Heat C 1490 1452 D 1357 1315 A 2149 2114 B 2013 1977 High Cool C 1936 1900 D 1719 1685 A 1629 1591 B 1558 1516 Low Cool C 1453 1406 D 1410 1361 60065 A 1276 1219 B 1133 1068 High Heat C 1025 950 D 844 748 A 1228 1169 B 1086 1017 Low Heat C 844 748 D 786 666 Continued on next page. See notes at end of table. Johnson Controls Unitary Products 0.3 SCFM 1781 1630 1554 1298 1406 1298 1238 1197 1004 937 816 716 982 766 641 533 1781 1630 1554 1298 1406 1298 1238 1197 1645 1441 1238 1157 1318 1157 1027 841 1781 1630 1554 1298 1406 1298 1238 1197 1974 1887 1720 1554 1974 1887 1423 1278 2077 1941 1864 1642 1546 1469 1355 1307 1158 995 868 651 1104 940 651 593 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 1746 1707 1656 1609 1504 1461 1597 1556 1520 1477 1424 1382 1145 1100 1255 1204 1368 1320 1264 1220 1145 1100 1255 1204 1191 1138 1077 1030 1032 984 1149 1095 944 882 813 758 735 678 871 806 742 672 596 534 480 412 633 559 919 857 787 732 538 473 688 616 552 475 392 321 266 189 435 353 1746 1707 1656 1609 1504 1461 1597 1556 1520 1477 1424 1382 1145 1100 1255 1204 1368 1320 1264 1220 1145 1100 1255 1204 1191 1138 1077 1030 1032 984 1149 1095 1612 1572 1520 1477 1302 1259 1404 1358 1191 1138 1077 1030 987 938 1107 1051 1276 1226 1168 1123 987 938 1107 1051 968 907 839 785 625 564 769 700 1746 1707 1656 1609 1504 1461 1597 1556 1520 1477 1424 1382 1145 1100 1255 1204 1368 1320 1264 1220 1145 1100 1255 1204 1191 1138 1077 1030 1032 984 1149 1095 1914 1874 1815 1745 1752 1697 1844 1806 1687 1647 1596 1551 1424 1382 1520 1477 1914 1874 1815 1745 1752 1697 1844 1806 1386 1339 1283 1240 1123 1077 1234 1182 2030 1989 1948 1905 1816 1772 1898 1860 1822 1783 1739 1695 1508 1465 1600 1555 1502 1455 1409 1362 1329 1280 1423 1375 1305 1255 1207 1153 1155 1100 1255 1204 1098 1040 987 927 793 730 922 849 788 713 654 591 433 372 563 494 1039 976 922 861 728 664 863 786 563 494 433 372 370 314 514 453 0.8 SCFM 1552 1404 1324 1044 1164 1044 975 930 707 628 485 366 680 426 276 147 1552 1404 1324 1044 1164 1044 975 930 1419 1203 975 884 1067 884 733 515 1552 1404 1324 1044 1164 1044 975 930 1696 1643 1494 1324 1696 1643 1183 1021 1859 1726 1649 1418 1315 1232 1100 1044 869 680 505 168 806 617 168 263 0.9 SCFM 1518 1368 1286 993 1119 993 920 872 635 550 398 270 606 334 174 100 1518 1368 1286 993 1119 993 920 872 1384 1159 920 824 1017 824 663 430 1518 1368 1286 993 1119 993 920 872 1645 1604 1459 1286 1645 1604 1139 969 1816 1677 1597 1372 1266 1181 1047 992 818 634 458 115 757 573 115 180 1.0 SCFM 1460 1310 1228 933 1060 933 859 810 569 484 329 199 541 264 101 85 1460 1310 1228 933 1060 933 859 810 1327 1101 859 761 957 761 598 361 1460 1310 1228 933 1060 933 859 810 1582 1545 1402 1228 1582 1545 1080 908 1768 1630 1551 1327 1220 1135 997 938 761 579 415 105 700 519 105 38 15 5291598-LTG-B-1216 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued) Model Jumper Position High Cool Low Cool 60100 High Heat Low Heat High Cool Low Cool 60125 High Heat Low Heat A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D 0.1 SCFM 2149 2013 1936 1719 1629 1558 1453 1410 1739 1558 1410 1323 1594 1323 1181 1025 2149 2013 1936 1719 1629 1558 1453 1410 2259 2093 1908 1760 2259 1965 1701 1683 0.2 SCFM 2114 1977 1900 1685 1591 1516 1406 1361 1705 1516 1361 1270 1553 1270 1118 950 2114 1977 1900 1685 1591 1516 1406 1361 2221 2059 1872 1726 2221 1929 1666 1648 0.3 SCFM 2077 1941 1864 1642 1546 1469 1355 1307 1664 1469 1307 1213 1507 1213 1049 868 2077 1941 1864 1642 1546 1469 1355 1307 2183 2023 1835 1685 2183 1893 1623 1604 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 2030 1989 1948 1905 1816 1772 1898 1860 1822 1783 1739 1695 1508 1465 1600 1555 1502 1455 1409 1362 1329 1280 1423 1375 1305 1255 1207 1153 1155 1100 1255 1204 1620 1577 1530 1487 1329 1280 1423 1375 1255 1204 1155 1100 1052 993 1156 1104 1462 1415 1369 1321 1052 993 1156 1104 980 913 857 795 654 591 788 713 2030 1989 1948 1905 1816 1772 1898 1860 1822 1783 1739 1695 1508 1465 1600 1555 1502 1455 1409 1362 1329 1280 1423 1375 1305 1255 1207 1153 1155 1100 1255 1204 2142 2099 2060 2015 1896 1852 1977 1938 1792 1753 1709 1665 1552 1510 1641 1598 2142 2099 2060 2015 1769 1724 1851 1813 1580 1535 1488 1445 1468 1424 1560 1515 0.8 SCFM 1859 1726 1649 1418 1315 1232 1100 1044 1441 1232 1044 933 1274 933 743 505 1859 1726 1649 1418 1315 1232 1100 1044 1975 1805 1619 1463 1975 1678 1397 1377 0.9 SCFM 1816 1677 1597 1372 1266 1181 1047 992 1393 1181 992 880 1223 880 696 458 1816 1677 1597 1372 1266 1181 1047 992 1931 1760 1566 1413 1931 1628 1351 1330 1.0 SCFM 1768 1630 1551 1327 1220 1135 997 938 1348 1135 938 821 1178 821 640 415 1768 1630 1551 1327 1220 1135 997 938 1882 1712 1522 1370 1882 1580 1305 1284 NOTES: 1. 2. 3. 4. 5. 6. 16 Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Minimal variations in airflow performance data results from using downflow duct applications. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5291598-LTG-B-1216 ADDITIONAL STATIC RESISTANCE Size (Tons) 036 (3.0) 042 (3.5) 048 (4.0) 060 (5.0) CFM 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Wet Indoor Coil Economizer1 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 BOTTOM DUCT DIMENSIONS (Inches) Filter/Frame Kit 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.18 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 ' 9,(:/22.,1*83 $7%277202)81,7 & $ 5(7851 $,5'8&7 ( % $ 6833/< $,5'8&7 ) Model 36, 42, 48, 60 A 14 B 13.5 $ C 5 D 3.5 E 47.5 F 42 REAR DUCT DIMENSIONS (Inches) NOTES: 1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. 6833/< $,5'8&7 5(7851 $,5'8&7 $ Model 36, 42, 48, 60 Johnson Controls Unitary Products $ % A 13.6 $ B 14 17 5291598-LTG-B-1216 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324-001 UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN AIR DUCT SUPPLY AIR DUCT FIELD-SUPPLIED DISCONNECT SWITCH CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE TO GAS SUPPLY LINE 18 CONTROL WIRING TO INDOOR THERMOSTAT A0325-001 Johnson Controls Unitary Products 5291598-LTG-B-1216 UNIT TYPICAL ROOF CURB INSTALLATION ROOF CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH TO GAS SUPPLY LINE TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT Johnson Controls Unitary Products SUPPLY AIR DUCT A0326-001 19 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2016 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5291598-LTG-B-1216 Supersedes: 5291598-LTG-A-1016
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement