SmartGen CMM366-WIFI Owner's Manual
Add to My manuals16 Pages
Smartgen CMM366-WIFI is a cloud monitoring communication module that allows you to monitor your generator's status and search running records in real-time using an app or PC. It connects to the internet via a wireless WIFI network and communicates with your generator via RS485, RS232, LINK, or USB ports. The module supports monitoring of generator parameters, digital alarm inputs/outputs, and location information. It also features a perpetual calendar and clock, lamp test function, and parameter adjustment via USB.
advertisement
![SmartGen CMM366-WIFI Owner's Manual | Manualzz SmartGen CMM366-WIFI Owner's Manual | Manualzz](http://s1.manualzz.com/store/data/038457663_1-2bb1461778000fb339373555290a87ea-360x466.png)
CMM366-WIFI
CLOUD MONITORING COMMUNICATION MODULE
USER MANUAL
SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD.
CMM366-WIFI Cloud Monitoring Communication Module User Manual
CONTENT
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 2 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
Chinese trademark
English trademark
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road
Zhengzhou
Henan Province
P. R. China
Tel: 0086-371-67988888/67981888
0086-371-67991553/67992951
0086-371-67981000(overseas)
Fax: 0086-371-67992952
Web: http://www.smartgen.com.cn
http://www.smartgen.cn
Email: [email protected]
All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.
Applications for the copyright holder’s written permission to reproduce any part of this publication should be addressed to Smartgen Technology at the address above.
Any reference to trademarked product names used within this publication is owned by their respective companies.
SmartGen Technology reserves the right to change the contents of this document without prior notice.
Software Version
Date
2016-08-15
Version
1.0 Original release.
Note
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 3 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
1 OVERVIEW
CMM366-WIFI Cloud Monitoring Communication Module is WIFI wireless network communication protocol switch module which can achieve genset (with SCI) connect to Internet. The module obtains genset data via RS485 port, USB port, LINK port or RS232 port of genset controller modules of international first-class brands including SmartGen, DeepSea, ComAp, etc. Then the module transmits the data to corresponding cloud server via WIFI wireless network for achieving user’s real-time monitoring to running status and searching of running records via APP (IOS or Android) and PC terminal devices.
CMM366-WIFI module has already integrated protocols of mainstream genset control module. It not only can monitor genset but also can receive some digital alarm input/output signals to achieve monitoring of generator room entrance guard, guard against theft and fire facilities.
2 PERFORMANCE AND CHARACTERISTICS
1) Connect to cloud server via wireless WIFI, one to one monitoring;
2) Multiple ports for communication with genset control module: RS485, RS232, LINK and USB
(Host); can monitor great majority genset control modules of international first-class brands;
3) Widely power supply: DC (8~35)V, can direct use genset build-in battery;
4) With ARM-based 32-bit SCM, high integration of hardware and strong programming ability;
5) Include with location information to realize genset location;
6) Take JSON network data communication protocol, upload real-time data variation and take compression algorithm to vastly reduce network flow at the same time;
7) Users can set up history data upload rest to upload monitoring data to server (history data can be analyzed);
8) When alarm occurs it can upload data to server immediately;
9) 2 auxiliary digital input ports which can receive external alarm signal;
10) 1 auxiliary relay output port which can output various of alarm signal;
11) Perpetual calendar and clock function;
12) Power and multiple communication status indicators on front panel that working status is clear at a glance;
13) Lamp test function;
14) Parameter adjust function: users can adjust parameters via USB port;
15) Take standard
π-type 35mm guide-rail installation or screw-fixed installation to install controller into the genset control box;
16) Modular design, self extinguishing ABS plastic shell, light weight, compact structure with easy installation.
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 4 of 16
3 SPECIFICATION
CMM366-WIFI Cloud Monitoring Communication Module User Manual
Items
Operating Voltage
Power Consumption
Digital Input Ports
Digital Output Ports
USB Host
RS485
RS232
LINK
USB Device
WIFI
Contents
DC 8.0V~35.0V, continuous power supply.
Standby:
≤2W
Working: ≤5W
Volts free digital input
1A DC30V Volts free output
A-type USB female port
Seclusion type
General type
SmartGen exclusive port
B-type USB female port
IPX antenna
Support 802.11b/g/n standard
73mmx105mmx35mm
Temperature: (-25~+70)°C Humidity: (20~93)%RH
Temperature: (-25~+80)°C
0.15kg
Case Dimensions
Working Conditions
Storage Condition
Weight
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 5 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
4 PANEL AND TERMINAL DESCRIPTION
4.1 PANEL INDICATOR AND BUTTONS
USB(Red)
Icon
POWER/ALARM
RS485(Red)
Note
Green LED Light: Power supply normal and connect to cloud server successfully.
Red LED Light: Common alarm indicator
Normally Off State: RS485 disabled
Normally Light: Communication fail
Blink: Communication normal
Normally Off State: USB(Host) disabled
Normally Light: Communication fail
Blink: Communication normal
Off State: CMM366-WIFI login with server unsuccessfully
WIFI(Red)
LINK(Red)
Light: Login with server successfully
Blink: Real-time communication normal
Normally Off State: Disabled
Normally Light: Communication fail
Blink: Communication normal
Normally Off State: RS232 disabled
RS232(Red)
Lamp test/Rest:
Press this button for 1s, all the LEDs are illuminated; press for 10s, reset the module to default and all the LEDs blink for 3 times.
Normally Light: Communication fail
Blink: Communication normal
Note: After reset the module, set up the parameters via PC software is recommended. Please operate cautiously.
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 6 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
4.2 WIFI ANTENNA INTERFACE
Connect WIFI antenna to the antenna interface of cloud monitoring communication module shown as follow:
4.3 RS485
Connect with genset controller via RS485 to receive genset data information.
If communication is abnormal, 120Ω terminal resistance is recommonded. One end of shield wire hangs in the air and the other one connects with SCR.
4.4 RS232
Connect with genset controller via RS232 to receive genset data information.
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 7 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
4.5 LINK
Connect with genset controller via LINK to receive genset data information.
4.6 USB HOST
Connect with genset controller via CMM366 A-type USB mother port and USB data cable to receive genset data information.
4.7 USB DEVICE
Connect with PC via USB port to set up all the parameters and view CMM366-WIFI ID&Login password.
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 8 of 16
12
13
8
9
10
11
4.8 TERMINAL
No. Function
1 B-
2
3
4
B+
CMM366-WIFI Cloud Monitoring Communication Module User Manual
Cable Size
1.0mm
1.0mm
2
2
Note
Connected with negative of starter battery.
Connected with positive of starter battery. 3A fuse is recommended.
Active when connect to B-.
Active when connect to B-.
5
6
7
Aux. Input 1
Aux. Input 2
1.0mm
2
1.0mm
2
Aux. Output
RS232 RX
RS232 TX
RS232 GND
RS485 B(-)
RS485 A(+)
SCR
Normally
1.0mm
2
Open
Common 1.0mm
2
Normally 1.0mm
2
Close
0.5mm
2
0.5mm
2
0.5mm
2
0.5mm
2
0.5mm
2
0.5mm
2
Normally open outputs, rated 1A DC30V
RS232
Impedance-120
Ω shielding wire is recommended, its single-end earthed.
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 9 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
5 PROGRAMMABLE PARAMETERS
5.1 CONTENTS AND SCOPES OF PARAMETERS
Parameter contents and scope :
Form1
No.
WIFI
Items Parameters Defaults Description
1 DHCP Enabled
2 IP Address
3 Subnet Mask
4 Gateway IP
5 DNS Address
6 MAC Address
7 SSID
8 Network Password
Gateway
(0-1)
(0-255)
(0-255)
(0-255)
(0-255)
(0-255)
(0-65535)
(0-65535)
1
192.168.0.101
255.255.255.0
192.168.0.2
32 bits
64 bits
0: Disabled
1: Enabled, auto acquire IP
211.138.24.66
00.08.DC.01.02.03
The changes of all Ethernet settings (such as: IP address,
Subnet mask, etc.) will be active after power on again.
1 Website
2 URL
3 Server Port
4 Password
GPS
1 Location Info
2 Longitude
(0-65535)
(0-65535)
(0-65535)
(0-65535) monitor.smartgen.com.cn
50158
123456
(0-1)
(-180-180)°
0
0.000000
3 Latitude
4 Altitude
(-90-90)° 0.000000
(-9999.9-9999.9) 100.0
Cloud Server
1
Auto Gain Comm.
(0-1)
Port
1
20 Chinese characters, letters or numbers
16 characters
40 characters
0: Disabled 1: Manual Input
GPS location, altitude
0: Disabled 1:Enabled
2
3
4
5
ID
Communication Port
Baud Rate
Location Info
6 Longitude
7 Latitude
8 Altitude
9 Type
10 Name
(1-254)
(0-4)
(0-2)
(0-1)
1
2
0
0
Module ID
0:Disabled;
1:LINK;
2:RS485;
3:RS232;
4:USB
0:9600bit/s;
1:19200bit/s
2:115200
0:Disabled
1:Manual input
(-180-180)°
(-90-90)°
0.000000
0.000000
(-9999.9-9999.9) 100.0
(0-65535)
GPS location, altitude
Module Names(20 Chinese characters, letters or
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 10 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
11
12
13
14
Debug Staff Name
Telephone
Installation Time
History Data Rest
15 Time Zone numbers)
20 Chinese characters, letters or numbers
20 Chinese characters, letters or numbers
20 Chinese characters, letters or numbers
(0-3600)s
16 Data Upload Interval
(1-20)s
Module Configuration Info
(-12-12)
0
8
5
History data upload rest.
Note: No upload when it is 0s
Time Zone
Real time data upload interval
1
2
3
4
5
6
Type
Rated Speed
AC Supply
Rated Volt
Rated Freq
Rated Current
(0-5)
(0-6000)r/min
(0-3)
(30-30000)V
(10-600)Hz
(5-6000)A
1
1500
0
230
50
500
0:AMF module
1:Single-unit self-starting module
2: Single-single parallel module
3:Mains-genset parallel module
4:Mains-bus parallel module
5:Bus-bus parallel module
Note: The parameter will auto change according to genset type.
Rated Speed
0:3P4W;1:3P3W;2:2P3W;3:1P2W。
Rated Volt
Rated Freq
Rated Current
7 Rated Power
8
9
10
11
12
(0-6000)kW
Custom Description 1 (0-65535)
Custom Description 2 (0-65535)
Custom Description 3 (0-65535)
Custom Description 4 (0-65535)
Custom Description 5 (0-65535)
276 Rated Power
Custom Description (20 Chinese characters, letters or numbers)
Custom Description (20 Chinese characters, letters or numbers)
Custom Description (20 Chinese characters, letters or numbers)
Custom Description (20 Chinese characters, letters or numbers)
Custom Description (20 Chinese characters, letters or numbers)
Digital Input
Digital Input 1
1 Setting (0-9) 0
2 Type (0-1)
(0-20.0)
0
0.0
Default: Not used
0:Active when close
1:Active when open
Action delay 3 Delay
Digital Input 2
3 Setting (0-9) 1
4
5
Type
Delay
Digital Output
(0-1)
(0-20.0)
0
0.0
Default: Lamp test
0:Active when close
Action delay
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 11 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
1 Setting (0-14)
Content of auxiliary input ports:
0
Form2
No.
0 Not Used
1 Lamp Test
Item Description
Not used.
All the indicators are illuminated when input is active.
2 Remote Control Inhibited Cloud start/stop control is prohibited when input is active.
3 Access Alarm Input Access alarm is uploaded to server when input is active.
4 Fire Alarm Input
5 Alarm Input
Fire alarm is uploaded to server when input is active.
External alarm is uploaded to server when input is active.
6
7
8
9
Reserved
Reserved
Reserved
Factory Test Mode
Content of auxiliary output ports:
Form3
No.
0 Not used
Item
1 Digital Input 1 Active
2 Digital Input 2 Active
3 RS485 Comm. Fail
4 Network Comm. Fail
It is only used for factory hardware port test when active.
Description
Output port won’t output when this item is selected.
Output when auxiliary input 1 is active.
Output when auxiliary input 2 is active.
RS485 communication fails.
Network communication fails.
5 LINK Comm. Fail
6 RS232 Comm. Fail
7 Common Alarm
8
9
10
11
12
13
14
Remote Control
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
module types:
Form4
Manufacturers
LINK communication fails.
RS232 communication fails.
Output when there is an alarm.
Send remote control command via cloud server, output fixed delay: 20s
SmartGen
Type
HGM6110
HGM6120
HGM7x10
HGM7x20
HGM410
HGM420
HGM9120
HGM9210
HGM9220
Note
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
AMF module
Single-unit self-starting module
AMF module
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 12 of 16
DeepSea
CMM366-WIFI Cloud Monitoring Communication Module User Manual
HGM9310
HGM9320
HGM9410
HGM9420
HGM9510
HGM9520
HGM9530
HGM9540
HGM9560
HGM9580
HGM9610
HGM9620
ZX9320
HSC940
DSE7110MKII
DSE7120MKII
DSE7210
DSE7220
DSE7310
DSE7320
DSE7410
DSE7420
DSE7450
DSE8610
DSE8620
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-single parallel module
Mains-genset parallel module
Single-single parallel module
Mains-genset parallel module
Mains-bus parallel module
Bus-bus parallel module
Single-unit self-starting module
AMF module
AMF module
Single-unit self-starting module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
Single-single parallel module
Mains-genset parallel module
MRS10
Ⅱ
Single-unit self-starting module
MRS16
Ⅱ
Single-unit self-starting module
ComAp
AMF25
Ⅱ
AMF module
Harsen
IGNT
GU620A
GU621A
GU630A
GU631A
GU620A-00
GU621A-00
GU630A-00
GU631A-00
GU320A
GU320B
Single-single parallel module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
AMF module
Single-unit self-starting module
Single-unit self-starting module
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 13 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
5.2 PC CONFIGURATION INTERFACE
The USB port of CMM366-WIFI communication module connects PC port to configure the parameters.
WIFI Configuration
Gateway Configuration
Cloud Server Configuration
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 14 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
Module Monitoring Interface
6 SYSTEM DIAGRAM
1 CMM366-WIFI module connects with 1 genset monitor module. It can be connected via RS485 port,
LINK port, RS232 port or USB port.
CMM366-WIFI System Diagram
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 15 of 16
CMM366-WIFI Cloud Monitoring Communication Module User Manual
7 CASE DIMENSION AND INSTALLATION
2 ways for installation: 35mm guide rail in box or screw (M4) installation as below:
CMM366-WIFI Case Dimension
CMM366-WIFI Guide Rail Installation CMM366-WIFI Screw Installation
8 FAULT FINDING
Symptoms Possible Solutions
Controller no response with Check power voltage; power. Check controller connection wirings.
Network Indicator Not Light
Check Ethernet parameters setting is correct or not;
Check network plug indicator is blinking or not;
Check cable is normal or not.
RS485
Abnormal
RS232
Abnormal
LINK
Abnormal
Check connections;
Communication Check RS485 port is enabled or not;
Check settings of genset ID and baud rate are correct or not.
Check RS485’s connections of A and B is reverse connect or not.
Communication
Check connections;
Check RS232 port is enabled or not;
Check settings of genset ID and baud rate are correct or not.
Communication
Check connections;
Check LINK port is enabled or not;
Check settings of genset ID and baud rate are correct or not.
CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 16 of 16
advertisement
Related manuals
advertisement
Table of contents
- 4 OVERVIEW
- 4 PERFORMANCE AND CHARACTERISTICS
- 5 SPECIFICATION
- 6 PANEL AND TERMINAL DESCRIPTION
- 6 PANEL INDICATOR AND BUTTONS
- 7 WIFI ANTENNA INTERFACE
- 7 RS485
- 7 RS232
- 8 LINK
- 8 USB HOST
- 8 USB DEVICE
- 9 TERMINAL
- 10 PROGRAMMABLE PARAMETERS
- 10 CONTENTS AND SCOPES OF PARAMETERS
- 14 PC CONFIGURATION INTERFACE
- 15 SYSTEM DIAGRAM
- 16 CASE DIMENSION AND INSTALLATION
- 16 FAULT FINDING