SmartGen CMM366-WIFI Owner's Manual

Add to My manuals
16 Pages

advertisement

SmartGen CMM366-WIFI Owner's Manual | Manualzz

CMM366-WIFI

CLOUD MONITORING COMMUNICATION MODULE

USER MANUAL

SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD.

CMM366-WIFI Cloud Monitoring Communication Module User Manual

CONTENT

1 OVERVIEW ......................................................................................................................................... 4

2 PERFORMANCE AND CHARACTERISTICS .................................................................................... 4

3 SPECIFICATION ................................................................................................................................. 5

4 PANEL AND TERMINAL DESCRIPTION........................................................................................... 6

4.1

PANEL INDICATOR AND BUTTONS .................................................................................................. 6

4.2

WIFI ANTENNA INTERFACE ............................................................................................................. 7

4.3

RS485 ................................................................................................................................................. 7

4.4

RS232 ................................................................................................................................................. 7

4.5

LINK .................................................................................................................................................... 8

4.6

USB HOST ......................................................................................................................................... 8

4.7

USB DEVICE ...................................................................................................................................... 8

4.8

TERMINAL ......................................................................................................................................... 9

5 PROGRAMMABLE PARAMETERS ................................................................................................. 10

5.1

CONTENTS AND SCOPES OF PARAMETERS .............................................................................. 10

5.2

PC CONFIGURATION INTERFACE ................................................................................................. 14

6 SYSTEM DIAGRAM.......................................................................................................................... 15

7 CASE DIMENSION AND INSTALLATION ....................................................................................... 16

8 FAULT FINDING ............................................................................................................................... 16

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 2 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

Chinese trademark

English trademark

SmartGen — make your generator smart

SmartGen Technology Co., Ltd.

No.28 Jinsuo Road

Zhengzhou

Henan Province

P. R. China

Tel: 0086-371-67988888/67981888

0086-371-67991553/67992951

0086-371-67981000(overseas)

Fax: 0086-371-67992952

Web: http://www.smartgen.com.cn

http://www.smartgen.cn

Email: [email protected]

All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.

Applications for the copyright holder’s written permission to reproduce any part of this publication should be addressed to Smartgen Technology at the address above.

Any reference to trademarked product names used within this publication is owned by their respective companies.

SmartGen Technology reserves the right to change the contents of this document without prior notice.

Software Version

Date

2016-08-15

Version

1.0 Original release.

Note

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 3 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

1 OVERVIEW

CMM366-WIFI Cloud Monitoring Communication Module is WIFI wireless network communication protocol switch module which can achieve genset (with SCI) connect to Internet. The module obtains genset data via RS485 port, USB port, LINK port or RS232 port of genset controller modules of international first-class brands including SmartGen, DeepSea, ComAp, etc. Then the module transmits the data to corresponding cloud server via WIFI wireless network for achieving user’s real-time monitoring to running status and searching of running records via APP (IOS or Android) and PC terminal devices.

CMM366-WIFI module has already integrated protocols of mainstream genset control module. It not only can monitor genset but also can receive some digital alarm input/output signals to achieve monitoring of generator room entrance guard, guard against theft and fire facilities.

2 PERFORMANCE AND CHARACTERISTICS

1) Connect to cloud server via wireless WIFI, one to one monitoring;

2) Multiple ports for communication with genset control module: RS485, RS232, LINK and USB

(Host); can monitor great majority genset control modules of international first-class brands;

3) Widely power supply: DC (8~35)V, can direct use genset build-in battery;

4) With ARM-based 32-bit SCM, high integration of hardware and strong programming ability;

5) Include with location information to realize genset location;

6) Take JSON network data communication protocol, upload real-time data variation and take compression algorithm to vastly reduce network flow at the same time;

7) Users can set up history data upload rest to upload monitoring data to server (history data can be analyzed);

8) When alarm occurs it can upload data to server immediately;

9) 2 auxiliary digital input ports which can receive external alarm signal;

10) 1 auxiliary relay output port which can output various of alarm signal;

11) Perpetual calendar and clock function;

12) Power and multiple communication status indicators on front panel that working status is clear at a glance;

13) Lamp test function;

14) Parameter adjust function: users can adjust parameters via USB port;

15) Take standard

π-type 35mm guide-rail installation or screw-fixed installation to install controller into the genset control box;

16) Modular design, self extinguishing ABS plastic shell, light weight, compact structure with easy installation.

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 4 of 16

3 SPECIFICATION

CMM366-WIFI Cloud Monitoring Communication Module User Manual

Items

Operating Voltage

Power Consumption

Digital Input Ports

Digital Output Ports

USB Host

RS485

RS232

LINK

USB Device

WIFI

Contents

DC 8.0V~35.0V, continuous power supply.

Standby:

≤2W

Working: ≤5W

Volts free digital input

1A DC30V Volts free output

A-type USB female port

Seclusion type

General type

SmartGen exclusive port

B-type USB female port

IPX antenna

Support 802.11b/g/n standard

73mmx105mmx35mm

Temperature: (-25~+70)°C Humidity: (20~93)%RH

Temperature: (-25~+80)°C

0.15kg

Case Dimensions

Working Conditions

Storage Condition

Weight

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 5 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

4 PANEL AND TERMINAL DESCRIPTION

4.1 PANEL INDICATOR AND BUTTONS

USB(Red)

Icon

POWER/ALARM

RS485(Red)

Note

Green LED Light: Power supply normal and connect to cloud server successfully.

Red LED Light: Common alarm indicator

Normally Off State: RS485 disabled

Normally Light: Communication fail

Blink: Communication normal

Normally Off State: USB(Host) disabled

Normally Light: Communication fail

Blink: Communication normal

Off State: CMM366-WIFI login with server unsuccessfully

WIFI(Red)

LINK(Red)

Light: Login with server successfully

Blink: Real-time communication normal

Normally Off State: Disabled

Normally Light: Communication fail

Blink: Communication normal

Normally Off State: RS232 disabled

RS232(Red)

Lamp test/Rest:

Press this button for 1s, all the LEDs are illuminated; press for 10s, reset the module to default and all the LEDs blink for 3 times.

Normally Light: Communication fail

Blink: Communication normal

Note: After reset the module, set up the parameters via PC software is recommended. Please operate cautiously.

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 6 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

4.2 WIFI ANTENNA INTERFACE

Connect WIFI antenna to the antenna interface of cloud monitoring communication module shown as follow:

4.3 RS485

Connect with genset controller via RS485 to receive genset data information.

If communication is abnormal, 120Ω terminal resistance is recommonded. One end of shield wire hangs in the air and the other one connects with SCR.

4.4 RS232

Connect with genset controller via RS232 to receive genset data information.

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 7 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

4.5 LINK

Connect with genset controller via LINK to receive genset data information.

4.6 USB HOST

Connect with genset controller via CMM366 A-type USB mother port and USB data cable to receive genset data information.

4.7 USB DEVICE

Connect with PC via USB port to set up all the parameters and view CMM366-WIFI ID&Login password.

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 8 of 16

12

13

8

9

10

11

4.8 TERMINAL

No. Function

1 B-

2

3

4

B+

CMM366-WIFI Cloud Monitoring Communication Module User Manual

Cable Size

1.0mm

1.0mm

2

2

Note

Connected with negative of starter battery.

Connected with positive of starter battery. 3A fuse is recommended.

Active when connect to B-.

Active when connect to B-.

5

6

7

Aux. Input 1

Aux. Input 2

1.0mm

2

1.0mm

2

Aux. Output

RS232 RX

RS232 TX

RS232 GND

RS485 B(-)

RS485 A(+)

SCR

Normally

1.0mm

2

Open

Common 1.0mm

2

Normally 1.0mm

2

Close

0.5mm

2

0.5mm

2

0.5mm

2

0.5mm

2

0.5mm

2

0.5mm

2

Normally open outputs, rated 1A DC30V

RS232

Impedance-120

Ω shielding wire is recommended, its single-end earthed.

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 9 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

5 PROGRAMMABLE PARAMETERS

5.1 CONTENTS AND SCOPES OF PARAMETERS

Parameter contents and scope :

Form1

No.

WIFI

Items Parameters Defaults Description

1 DHCP Enabled

2 IP Address

3 Subnet Mask

4 Gateway IP

5 DNS Address

6 MAC Address

7 SSID

8 Network Password

Gateway

(0-1)

(0-255)

(0-255)

(0-255)

(0-255)

(0-255)

(0-65535)

(0-65535)

1

192.168.0.101

255.255.255.0

192.168.0.2

32 bits

64 bits

0: Disabled

1: Enabled, auto acquire IP

211.138.24.66

00.08.DC.01.02.03

The changes of all Ethernet settings (such as: IP address,

Subnet mask, etc.) will be active after power on again.

1 Website

2 URL

3 Server Port

4 Password

GPS

1 Location Info

2 Longitude

(0-65535)

(0-65535)

(0-65535)

(0-65535) monitor.smartgen.com.cn

50158

123456

(0-1)

(-180-180)°

0

0.000000

3 Latitude

4 Altitude

(-90-90)° 0.000000

(-9999.9-9999.9) 100.0

Cloud Server

1

Auto Gain Comm.

(0-1)

Port

1

20 Chinese characters, letters or numbers

16 characters

40 characters

0: Disabled 1: Manual Input

GPS location, altitude

0: Disabled 1:Enabled

2

3

4

5

ID

Communication Port

Baud Rate

Location Info

6 Longitude

7 Latitude

8 Altitude

9 Type

10 Name

(1-254)

(0-4)

(0-2)

(0-1)

1

2

0

0

Module ID

0:Disabled;

1:LINK;

2:RS485;

3:RS232;

4:USB

0:9600bit/s;

1:19200bit/s

2:115200

0:Disabled

1:Manual input

(-180-180)°

(-90-90)°

0.000000

0.000000

(-9999.9-9999.9) 100.0

HGM6110 See: Form4

(0-65535)

GPS location, altitude

Module Names(20 Chinese characters, letters or

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 10 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

11

12

13

14

Debug Staff Name

Telephone

Installation Time

History Data Rest

15 Time Zone numbers)

20 Chinese characters, letters or numbers

20 Chinese characters, letters or numbers

20 Chinese characters, letters or numbers

(0-3600)s

16 Data Upload Interval

(1-20)s

Module Configuration Info

(-12-12)

0

8

5

History data upload rest.

Note: No upload when it is 0s

Time Zone

Real time data upload interval

1

2

3

4

5

6

Type

Rated Speed

AC Supply

Rated Volt

Rated Freq

Rated Current

(0-5)

(0-6000)r/min

(0-3)

(30-30000)V

(10-600)Hz

(5-6000)A

1

1500

0

230

50

500

0:AMF module

1:Single-unit self-starting module

2: Single-single parallel module

3:Mains-genset parallel module

4:Mains-bus parallel module

5:Bus-bus parallel module

Note: The parameter will auto change according to genset type.

Rated Speed

0:3P4W;1:3P3W;2:2P3W;3:1P2W。

Rated Volt

Rated Freq

Rated Current

7 Rated Power

8

9

10

11

12

(0-6000)kW

Custom Description 1 (0-65535)

Custom Description 2 (0-65535)

Custom Description 3 (0-65535)

Custom Description 4 (0-65535)

Custom Description 5 (0-65535)

276 Rated Power

Custom Description (20 Chinese characters, letters or numbers)

Custom Description (20 Chinese characters, letters or numbers)

Custom Description (20 Chinese characters, letters or numbers)

Custom Description (20 Chinese characters, letters or numbers)

Custom Description (20 Chinese characters, letters or numbers)

Digital Input

Digital Input 1

1 Setting (0-9) 0

2 Type (0-1)

(0-20.0)

0

0.0

Default: Not used

0:Active when close

1:Active when open

See: Form2

Action delay 3 Delay

Digital Input 2

3 Setting (0-9) 1

4

5

Type

Delay

Digital Output

(0-1)

(0-20.0)

0

0.0

Default: Lamp test

0:Active when close

1:Active when open See: Form2

Action delay

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 11 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

1 Setting (0-14)

Content of auxiliary input ports:

0

Default: Not used See: Form3

Form2

No.

0 Not Used

1 Lamp Test

Item Description

Not used.

All the indicators are illuminated when input is active.

2 Remote Control Inhibited Cloud start/stop control is prohibited when input is active.

3 Access Alarm Input Access alarm is uploaded to server when input is active.

4 Fire Alarm Input

5 Alarm Input

Fire alarm is uploaded to server when input is active.

External alarm is uploaded to server when input is active.

6

7

8

9

Reserved

Reserved

Reserved

Factory Test Mode

Content of auxiliary output ports:

Form3

No.

0 Not used

Item

1 Digital Input 1 Active

2 Digital Input 2 Active

3 RS485 Comm. Fail

4 Network Comm. Fail

It is only used for factory hardware port test when active.

Description

Output port won’t output when this item is selected.

Output when auxiliary input 1 is active.

Output when auxiliary input 2 is active.

RS485 communication fails.

Network communication fails.

5 LINK Comm. Fail

6 RS232 Comm. Fail

7 Common Alarm

8

9

10

11

12

13

14

Remote Control

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

module types:

Form4

Manufacturers

LINK communication fails.

RS232 communication fails.

Output when there is an alarm.

Send remote control command via cloud server, output fixed delay: 20s

SmartGen

Type

HGM6110

HGM6120

HGM7x10

HGM7x20

HGM410

HGM420

HGM9120

HGM9210

HGM9220

Note

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

AMF module

Single-unit self-starting module

AMF module

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 12 of 16

DeepSea

CMM366-WIFI Cloud Monitoring Communication Module User Manual

HGM9310

HGM9320

HGM9410

HGM9420

HGM9510

HGM9520

HGM9530

HGM9540

HGM9560

HGM9580

HGM9610

HGM9620

ZX9320

HSC940

DSE7110MKII

DSE7120MKII

DSE7210

DSE7220

DSE7310

DSE7320

DSE7410

DSE7420

DSE7450

DSE8610

DSE8620

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-single parallel module

Mains-genset parallel module

Single-single parallel module

Mains-genset parallel module

Mains-bus parallel module

Bus-bus parallel module

Single-unit self-starting module

AMF module

AMF module

Single-unit self-starting module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

Single-single parallel module

Mains-genset parallel module

MRS10

Single-unit self-starting module

MRS16

Single-unit self-starting module

ComAp

AMF25

AMF module

Harsen

IGNT

GU620A

GU621A

GU630A

GU631A

GU620A-00

GU621A-00

GU630A-00

GU631A-00

GU320A

GU320B

Single-single parallel module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

AMF module

Single-unit self-starting module

Single-unit self-starting module

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 13 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

5.2 PC CONFIGURATION INTERFACE

The USB port of CMM366-WIFI communication module connects PC port to configure the parameters.

WIFI Configuration

Gateway Configuration

Cloud Server Configuration

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 14 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

Module Monitoring Interface

6 SYSTEM DIAGRAM

1 CMM366-WIFI module connects with 1 genset monitor module. It can be connected via RS485 port,

LINK port, RS232 port or USB port.

CMM366-WIFI System Diagram

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 15 of 16

CMM366-WIFI Cloud Monitoring Communication Module User Manual

7 CASE DIMENSION AND INSTALLATION

2 ways for installation: 35mm guide rail in box or screw (M4) installation as below:

CMM366-WIFI Case Dimension

CMM366-WIFI Guide Rail Installation CMM366-WIFI Screw Installation

8 FAULT FINDING

Symptoms Possible Solutions

Controller no response with Check power voltage; power. Check controller connection wirings.

Network Indicator Not Light

Check Ethernet parameters setting is correct or not;

Check network plug indicator is blinking or not;

Check cable is normal or not.

RS485

Abnormal

RS232

Abnormal

LINK

Abnormal

Check connections;

Communication Check RS485 port is enabled or not;

Check settings of genset ID and baud rate are correct or not.

Check RS485’s connections of A and B is reverse connect or not.

Communication

Check connections;

Check RS232 port is enabled or not;

Check settings of genset ID and baud rate are correct or not.

Communication

Check connections;

Check LINK port is enabled or not;

Check settings of genset ID and baud rate are correct or not.

CMM366-WIFI Cloud Monitoring Communication Module 2016-08-15 Version 1.0 Page 16 of 16

advertisement