Sea Gull Lighting 49180BLE-98 Installation Guide

Add to My manuals
2 Pages

advertisement

Sea Gull Lighting 49180BLE-98 Installation Guide | Manualzz

INSTALLATION AND SAFETY INSTRUCTIONS

FOR YOUR SAFETY

WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU

ARE WORKING ON IS SHUT OFF. EITHER THE FUSE REMOVED

OR THE CIRCUIT BREAKER OFF .

ASSEMBLY

STEP 1:

Carefully remove the fixture from the carton and check that all parts are included, as shown in Figure 1& 2. Be careful not to misplace any of the screws or parts which are needed to install this fixture.

GENERAL

You don’t need special tools to install this fixture. Be sure to follow the steps in the order given. Under no circumstances should a fixture be hung on house electrical wires, nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system.

Read instructions carefully. If you are unclear as to how to proceed, consult a qualified electrician.

NOTE: Proper wiring is essential for the safe operation of this fixture.

STEP 2:

Snap sockets (A) to faceplate (F) ( if applicable).

STEP 3:

Insert short threaded side of pipe (B) thru front plate (F) (as shown in

Fig. 1). Place lock washer (C) on pipe (B) & secure in place with nut

(D) (if applicable).

NUT (D)

(J)

FACE PLATE (F)

LOCK WASHER (C)

SOCKET (A)

PIPE (B)

FIBER WASHER (M)

*WIRE CONNECTOR

CAP NUT (G)

SHORT NIPPLE (E)

DIFFUSER (N)

DECORATIVE CAP NUT (H)

(FIG. 1)

*NOT SUPPLIED

GROUNDING & UNIVERSAL MOUNTING

BAR LOCK UP (FIG. 2)

GREEN

GROUNDING

SCREW (L)

*OUTLET BOX

SCREWS

*OUTLET BOX

MOUNTING SCREWS (I)

UNIVERSAL

MOUNTING

PLATE (J)

*WIRE CONNECTOR

(FIG. 2)

*NOT SUPPLIED

ITEM #

Fill in item number located on carton and file this sheet for future reference

HC-242

101800

INSTALLATION HC-242

IMPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET

BOX.

I

F SUPPLY WIRES ARE LOCATED WITHIN

3” OF BALLAST, USE WIRE RATED FOR

AT LEAST 90˚C

STEP 1:

Insert fixture mounting screws (I) in threaded holes of universal mounting bar (J). Run screws all the way down to the heads.

STEP 2:

Place universal mounting bar (J) against outlet box (not suppplied) and screw in place using outlet box screws (not supplied). Be sure the mounting screws are perfectly horizontal so fixture hangs straight.

STEP 3:

A. Take note of the color of the wire(s) on your fixture. Identify which group your fixture wire(s) falls into and connect the wires according to the directions below:

GROUP A: CONNECT TO BLACK

HOUSE WIRE

BLACK

GROUP B: CONNECT TO WHITE

HOUSE WIRE

WHITE

* PARALLEL WIRE (ROUND & SMOOTH) * PARALLEL WIRE (SQUARE & RIDGED)

WHITE OR GREY WITH TRACER WHITE OR GREY WITHOUT TRACER

BROWN, GOLD OR BLACK WITHOUT

TRACER

BROWN, GOLD OR BLACK WITH TRACER

* NOTE: When parallel wire is used, the tracer wire is square shaped or ridged, and the less tracer wire is round in shape or smooth. (Seen best when viewed from wire end.) To separate wires, grasp the ends of each wire and pull apart.

B. Take your fixture wire(s) from group A and place evenly against the black wire from the outlet box. Do Not twist wires together before using wire connectors.

C. Fit a wire connector (not supplied) over the wires and screw the connector clockwise until you feel a firmness.

D. Try gently to pull the connector off the wires. If you can pull the connector off, carefully re-do steps B and C, as above, and check again for a firm connection.

E. Connect the fixture wire from group B to the white wire from the outlet box in the same manner.

STEP 4:

GROUNDING INSTRUCTIONS: The green grounding screw (L) is to be inserted into the hole with two raised dimples provided on the universal mounting bar (J). Wrap the ground wire from the fixture (if supplied) and the ground wire from the outlet box (bare metal or green insulated wire) around the green grounding screw (L) on the universal mounting bar (J). If uninsulated ground wire is on the universal mounting bar, connect the ground wire from the fixture (if supplied) and the outlet box to it using a small wire connector (not supplied)

(See Figure 2).

NOTE: Underwriters Laboratories does not require all fixtures to have ground wires. These fixtures still meet all U.L. specifications.

NEVER CONNECT GROUND WIRE TO BLACK OR WHITE

POWER SUPPLY WIRES.

FINAL ASSEMBLY

Make sure no bare wires can be seen outside wire connectors.

STEP 1:

After wires are connected, tuck them carefully inside the outlet box.

Position backplate (F) over mounting screws (I) and secure in place with cap nut (G).

STEP 2:

Insert short nipple (E) into diffuser (N) (as shown in Fig.1) & secure with decorative cap nut (H) (if applicable).

STEP 3:

Install lamps.

STEP 4:

Install fiber washer (M) and diffuser (N), in that order, onto pipe (B).

Secure with decorative cap nut (H).

CLEANING

To clean, wipe fixture with a soft cloth. Clean glass with a mild soap.

Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

ORDERING PARTS